Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
08-0282 (AR)
yP.O� BOX 1504 VOICE (760) 777-7012- 78-495 CALLE TAMPICO FAX (760) 777-7011 ' LA QUINTA, CALIFORNIA 92253 - - BUILDING &SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT ` r Date: 7/23/08 Application Number, e08-00000282 Owner: Property.Address: 48137 -VIA' HERMOSA } WATSON PETER & IRENE APN: 646-100-003- - - 48-137 VIA HERMOSP Application description: ADDITION - RESIDENTIAL ` '' LA QUINTA, CA 9225 '- Property Zoning: LOW DENSITY RESIDENTIAL ( Application valuation: - 40000 L� D } -Contractor. JUL 2 3 2003 Applicant: Architect or Engineer: GARSEP CONSTRUCTI N f 710 E. SAN YSIDRO BL u ~ SAN YSIDRO, CA 92 73 C1 OF FINANCE QUINTA, (760)567-9682 DEPT. v. Lic. No. 893441 -------------------------------------------------------------------------------------------------- • LICENSED CONTRACTOR'S DECLARATION - WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: ` Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect._ I.have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: 13 License N .: 893441 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is ��)i•�% issued. E. . - Date:L/,Contractor: ; L I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor � Code, for the performance of the work for which this permit is issued. My workers' compensation - • OWNER -BUILDER DECLARATION insurance carrier and policy number are: - I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier EXEMPT Policy Number EXEMPT following 'reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any - construct, alter; improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to theprovisions of the Contractor's State and agree that, if I should become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the Labor Code, I shall forthwith comply with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by 8 Applicant:� any applicant fora permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: Date. (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and rte! the structure is not intended or offeredfor sale (Sec. 7044, Business and Professions Code: 'The' WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,_ AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN .improvements are not intended or offered for sale. If, however, the building or improvement is sold within, _ SECTION 3706 OF THE LABOR CODE_, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).APPLICANT ACKNOWLEDGEMENT 1—) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the ' 7844, 15ueinwu m.J Rvfo:,,io.,u Ooda! Tho O61%tr881er0' Ciotti Livvnm LQ- dons nnr 'PPhr rn an rnnmur of nnnditinn5 and restrirtiQn5 5% forth qn this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1 . Each person upon whose behalf this application is made, each person at wh696 fdjU8ST Bno Tor "pursuant to the Contractors' State License Law.). - - - whose benefit work is performed under or pursuant to any permit issued as aresult of this application, (_ ) I am exempt under Sec. , B.&P.C. for this reason the owner, and'the applicant, each agrees to, and shall defend, indemnify and hold harmless the City, of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit to cancellation. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the . I certify that I have read this application and state that the above information is correct. I agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). city and county ordinances and state lawsrelatingto building construction, and hereby authorize representatives - _ _ of this county to enter upon the above-mentioned property r inspection purpo_ • ..Lender's Name: _ " , - 7 , , • I atc{J`/--1- _ignatur (e Applicant or'Ag i (ip • ` _ Lender's Address: - -- - LQPERMIT '' t• Application Number 08-00000282. ..Permit BUILDING PERMIT Additional desc . Permit Fee . . 349.50 Plan Check Fee 227.18 Issue Date Valuation . . ." 40000 Expiration Date 1/19/09 Qty Unit Charge Per Extension. BASE FEE 252.00 15.00• 6.5000 ----------------------------------------------------------------------------- THOU- BLDG 25,001-50,000 97.50 Permit ELECT - ADD/ALT/REM , Additional desc . Permit Fee . . . . 26.76 Plan Check Fee 6.6'9 Issue Date . . . . Valuation . . . 0 Expiration -Date 1/19/09 ,Qty Unit Charge Per Extension BASE FEE 15.00 ' 336.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 11.76 Permit GRADING PERMIT Additional desc . Permit Fee 15.00 Plan Check Fee '. .00 Issue Date . . Valuation . . . . 0 Expiration Date 1/19/09 Qty Unit Charge Per Extension RASE FEE 15.00 Permit . . MECHANICAL Additional desc . Permit Fee . . . . 43.50 Plan Check Fee 10.88' Issue Date . . Valuation 0 Expiration Date 1/19/09 Qty Unit Charge. Per Extension . BASE FEE 15.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 2.00 6.5000 EA MECH VENT FAN 13,nn 1.00 6.5000 -------------------------- EA MECH ------------ EXHAUST HOOD ----------------- -------- 6.50. ------- - - - - -- - Permit. . PLUMBING Additional desc LQPERMIT Nmiii Application Number . . . . 08-00000282 Permit PLUMBING Permit.Fee•:. 55.50 Plane Check Fee 1'3:88 Issue Date Valuation 0 Expiration Date 1/19/09' Qty Unit Charge Per Extension BASE FEE 15.00 5.00 6.0000 EA PLB FIXTURE 30-"00„ 1.00 7.5000 EA PLB WATER HEATER/VENT - 7.50 3.0000 EA" PLB WATER INST/ALT/REP 3.00 -------------------------------- ------------------------------------------- Special Notes and Comments REM / ADDITION 336 SQ. FT. AND INTERIOR REMODEL:" ------------------------------------------------------ Other Fees . . . . . . . ENERGY REVIEW FEE 22.72 STRONG MOTION (SMI) - RES 4.00 Fee summary Charged Paid Credited -Due Permit Fee Total 490.26 .00 00 490.26 Plan Check Total 258.63 .00 .00• 258.63 Other Fee Total 26.72 .00 .00 26.72 Grand Total 775.61 .00 .00 775.61 LQPERMIT .. -35 .Bin # - �; ty of .La QuInta A f t - yF Building & Safety. Division' 00'� ;"' 'P.O. Box 1504, 78-495 Calle Tampico -'� La Quinta, CA 92253.- (760) 777-7012 Building Permit Application and Tracking Sheet. Permit # Z(�Z, Project Address: `46-1:33; a Owner's Name: A. P. Number' (p — :10�- ©O Address: 1.48-13 V w opy �6 c i Legal "Description:1 �S Contractor: City, ST, Zip:, ; �• Telephone:( - � — � Address:" . Project Description: s, City, ST, Zip:. _ Telephone: State Lic. # :. City Lic. #: Arch., Engr., Designer: LTJ .0 l A Address': - 12-- 2 —City, City,ST, Zip: ab GA� 612,7)1. s Telephone: �jL`�_ 35a Construction Type: Occupancy: State Lic. #: Project type (circle one): New Add'n_ Alter Repair Demo . Name of Contact Person: O Y - e 5 Sq. Ft.: �w # Stories: # Units: Telephone # of Contact" Person: 1%O 34o` -3 i Estimated Value.of Project -4 4 0 Q OG . APPLICANT: DO NOT WRITE BELOW THIS LINE � t # Submittal Req'd Rec'd TRACKING 10! PERMIT FEES Plan Sets ," zl� Plan Check submitted Item i Amount ' Structural Calcs. Reviewed, ready for corrections 2fz-7 Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance - Energy Calcs. Plans picked upConstruction Flood plain plan Plans resubmitted ~�- Mechanical Grading plan" 2°" Review, ready 4r corrections/is Electrical ' Subcontactor ListCalled Contact Person (j/28 • Plumbing`" , Grant Deed Plans, picked up S.M.I. H.O.A. Approval ' Plans resubmitted Grading ; IN HOUSE:- Review, ready for correcti s/issue 2 Developer Impact Fee Planning Approval Called Contact Person Pub. Wks. Appr Date of permit issue ' School Fees(Z- ..; • A� st ti tal PermE Fees Z(�S -NIS RtT RFc -cP��T/i5 Lot #1 No. 4Street S.F. Lot # -No. • Street S.F. Unit 1 48137 Via Hermosa 336' Unit 6 X Unit 2 _ Unit 7� i Unit 3 Unit 8 . rr Unit 4 •, Unit9 Unit 5 Unit 10 ; Comments • 1 At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: r Residential Addition 500 Sq,Feet or Less ., ,EXEMPT, This certifies that school facility fees imposed pursuant to F Education Code Section 17620 and Government,Code 65995 Et Seq. in the amount of $0.00 X 336 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Peter Watson Check No. Name on the check" - "Y . Telephone • Funding Exempt By Dr. Sharon P. McGehee �. Superintendent ? w �ti�t.Y �,� • . Fee collected lexemitited byn Gilvrey Payment Recd R. V -. Signature. s _ - •L�i.' £� t .rte NOTICE: Pursuant to Government Code Section 6602 d)(1), is will serve to notify you that the 90 -day approval period in, which yourmay protest the fees o r other payment identified above will begin to run from t e d on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another pu Ic entity authorized to collect them on the District('s) behalf, whichever is earlier. S' NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting Letter of Transmittal To: City of La Quinta Today's Date: p p 78-495 Calle Tampico City Due Date _ La Quinta, Ca 92253 Project Address: r Attn: Plan Check #: Submittal: ❑ 1st ❑ ,4th ❑ 2nd ❑ 5th - 3`d ❑ Other: We are forwarding: By Messenger ❑ By Mail (Fed Ex or UPS) • ❑ Your Pickup. Includes: # Of -' ''^ Descriptions: Includes: # Of Descriptions: Copies: Copies: ❑ Structural Plans ' Revised Structural Plans ` c❑ ,; Structural Calcs Revised Structural Calcs ❑ Truss Calcs ❑ Revised Truss Calcs ❑ Soils Report ❑ Revised Soils Report ❑ Correction List ❑ Approved Structural Plans - Redlined Structural Plans ❑ Approved Structural Calcs" Redlined Structural Calcs ❑ Approved Truss Calcs _ ❑. Redlined Truss Calcs ❑ Approved Soils Report ❑ Redlined Soils Reports ❑ Other: Comments:'(�lRr f/VY��, 0"00'p�S��h�Gl� n. c Thank you! This Materi"al'Sent for: ❑ Your Files 'C7f Per Your Request ❑ Your Review ❑ Approval .ti ❑ Checking ❑ • At the request of: Other: ❑ By: (V�� Palm Desert Office E]# (760) 360-5770 Washington Office : ❑ # (760) 404-9556 RESIDENTIAL KITCHEN LIGHTING WORKSHEET Project Title ? Date WS -5R i I v Ivrr r!!h►Ltq VW%..) %.viu J7AJ 5 [n22dVVtJL.X, I (_/ __ LY) / 4 A }L'. I At least 50% of the total rated wattage of permanently installed luminaires in the kitchen must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens.' Luminaire Type High Efficacy? Watts x Quanti ' = High Efficacy Watts or Other Watts C Yesl No o x — iii() or --UJ Yes o Nom x = or Q Yes o No o x = or Yes o No o x = or Yes o No o x = or Total: A: .1-3 CB: 0 - COMPLIES IF A > B Ye> No o Rules for Determining Residential Kitchen Luminaire Wattage Screw Base Sockets §130(c)1 (Not containing permanently installed ballasts) The maximum relamping rated wattage of the luminaire, as listed on a permanent factory -installed label (luminaire wattage is'not based on type or wattage of lamp that is used). Permanently or Remotely Installed Ballasts §130(c) 2 f The operating input wattage of the rated lamp/ballast combination based on values published in manufacturer's catalogs based on independent testing lab reports. Line Voltage Track Lighting (90 through 480 volts) §130(c) 3 1. Volt-ampere (VA) rating of the branch circuit(s) feeding the tracks; or 2. The higher of • The wattage (or VA) rating of an approved integral current limiter controlling the track system or • 15 watts per linear foot of the track; or 3. The higher of • 45 W per linear foot of the track or t The total wattage of all of the luminaires included in the system. 4 Low Voltage Track Lighting (less than 90 volts) §130(c) 4 a Rated wattage of the transformer feeding the system, as shown on a permanent factory -installed label Other Lighting §130(c) 5 (Lighting systems that are not addressed in §130 (c) 1-4) The maximum rated wattage, or operating input wattage of the system, listed on a permanent factory installed•label, or published in manufacturer's catalogs, based on independent testing ' iau re urrs. EXAMPLE - RESIDENTIAL•KITCHEN LIGHTING WORKSHEET WS -5R Project Title) Date ` Kitchen Lighting Schedule. Provide the following information foriall luminaires to be installed in kitchens.. High Efficacy: f Luminaire Type (yln)' ''Watts x. Quantity High Efficacy Watts. or Other Watts - .CFL -1: Yes < 26 X 5 = 130. or MR -16 No 55 x2 or 110 X or x _ or X , _ or Total: A: 130 B: 110 COMPLIES IF A, > B Yes Z' No o Residential Compliance Forms April 2005 'Pr®�eCt Summary ° . a Job: •, �Pl �19'� f'l®dlS� �,., Date: Feb 02, 2008 By: Mike Hyde`' t • Hyde's Air ConditioningA. ,. `. 77-825 Wildcat Drive, Palm Desert CA 92211-1137 Phone: (760) 360-2202 Fax: (760) 360-3350 Email: Michael@HydesAC.com Web: HydesAC.com cL ' _ . �• . For:' Peter Watson 48-137 Via Hermosa, La Quinta, CA'92253 FEB o g 2O0$ U Phone: (760) 771-3930 ,. • ., Notes: By 1. L+i,ES' ® 0 ® • ''u'="'.``�•-'"' ...tui `a.i'. '�.� _�. Weather: Palm Springs, CA, US Winter Design Conditions ,. : Summer Design Conditions Outside db• • ' ` ' 35 . OF .. Outside db �r 110 OF Inside db 70 OF, l } Design TD' ` 35 OF Inside db Design a s" 75 of 35 F Daily range H Relative humidity •.. 50 % + -Moisture difference -18- gr/Ib Heating Summary. ` . Sensible Cooling Equipment Load Sizing 1_ Building heat loss , �. 34652 Btuh Ventilaflon �,� ' Structure 33959 Btuh > air 47' cfmVentilation Ventilation air loss 1777 'Btuh "' Design temperature swing. ,1777 Btuh 3.0 F Design heat load,' 36429' Btuh,- Use mfg. data n t: Rate/swing multiplier 1.15 " Infiltration ' E. ,^ Total'sens. equip. load 41096 Btuh • Method � ' - . ^_ �• Simplified", Construction Average ' ., Latent Coolire Equipment Load Sizing • g E qupment quality, ..• ,. � • . ' Fireplaces r 1 (Average) ' Internal gains 1600 Btuh - • ' 'Heating . Cooling Ventilation Infiltration. -560 Btuh -1352 Btuh Area (f:2) • 2178 2178. Volume (ft9) 19395 •19395 Total latent equip. load - 0 Btuh,- Air changes/hour 7 0.70 '-`. Y 0.35 Equiv, AVF (cfm). 226 Total equipment load • 41096_. Btuh .. •113 — Req. total capacity at 0.70 SHR' l - 4.9 ton Heating Equipment Summary , Cooling Equipment Summary ' ,= - Make Trane ' r Make • Trane 5 ' '. Trade XR80 % - ' a • , Model -TUD080C960K* Trade- Trane - EPACT Cond . TTA060D3 t Efficiency - �',r 80 AFUE Coil . TXC065S3 Efficiency 0 EER Heating input = 80000 Btuh Heating output , 63000 ' Btuh Sensible cooling Latent cooling. _ 41300 Btuh 17700 Btuh Temperature rise. 39 OF = Actual air flow .1500 cfm ' Total cooling ` Actual air flow ; 59000 Btuh 1967 cfm % Air flow factor 0.043 cfm/Btuh Static pressure ,` 0.50 in H2O Air flow factor Static ' 0.058 cfmlBtuh cfm/Btu , " Space thermostat' , •rh pressure Load sensible heat ratio 0.50 H2O 102'% - , r i• U • ., - ' e . �try rev .. +w •Y .. '8ol�talic values have been manually overridden %:Printout Certified by ACCA to meet all requirements of Manual J 8th Ed. %A/reo1-btSC:),•t Right -Suite Residentia16 .9.11 RSR31639 ACCk Projectl xrp Calc = MJ8 Orientation = W r 2008 -Feb -02 18:16:33 Page 1 L/1F/Z000,.. The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: ADY683-0108 ` User Number: 5553 TITLE 24 REPORT = :Title 24 Report for: PETER & IRNE WATSON - LA QUINTA, CA CITY OF LA QUINTid1 . BUILDING & SAFETY DEM APPRO ED P oject Designer: FOR CONSTCT'IOt M &MRS. WATSON LA QUINTA, CA Report Prepared By: ` ADRIANA GIL Adriana Gil ` 74-854 Velie Way Ste. #8 • ' Palm Desert, CA 92260 (760) 404-7917 '. L Job Number: L/1F/Z000,.. The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: ADY683-0108 ` User Number: 5553 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 7 HVAC System Heating and Cooling Loads Summary 9 Certificate Of Compliance : Residential v(Part 1 of 4) CF -1 R P_E_T_E_ A-LRN.E_ .ATS_ON 2,188 Insulation 2/4/2QQ8 Project Title Type Frame Area Date -LA_ Q.0 I.NTA Cont. Azm. Tilt Project Address 1.,852_ _0.032_ Building Permit # _Ad.r_iarta Gil 0_ (760) 404-7917 Wall_ Wood_ Documentation Author _0.11.0_ Telephone Plan Check/Date vR -Ener-q- CA Climate_Zme 1.5 45.0_ Field Check/Date Complirice Method _R=0.0_ Climate Zone TDV Standard. Proposed Compliance _RAJ__R=0.0_-31.5__90 (kBtu/sf-yr} Design Design Margin Wall- Wood_ Space Heating 2.69 2.86 -0.18 _R=0.0_ Space Cooling 93.41 88.69 4.72 Fans 12.56 11.93 0.63 4.5__9.0 Domestic Hot Water 13.16 13.16 0.00 _0.11.0_ Pumps 0.00 0.00 0.00 Totals 121.82 116.65 5.17 _RAJ. Percent better than Standard: 0_ 4.2% _Roof Wood_ Building Type: [X] Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: z ❑ Addition (X-1 Existing + Add/Alt (SE)135 deg Natural Gas Area: 308 ft Avg. U: 0.52 Ratio: 14.1% Avg. SHGC: 0.35 BUILDING ZONE INFORMATION Zone Name Floor Area Volume .HVAC -Split -System 2,1.88 -1.9,692 OPAQUE SURFACES 2,188 Insulation Act. 1,852 Type Frame Area U -Fac. Cay. Cont. Azm. Tilt _RoO.t_, Wood- 1.,852_ _0.032_ -R=30_ _R=0.0_ 0_ 1.8 Wall_ Wood_ 31.7_ _0.11.0_ _R_11. _R=0..0_ _ 1.35.9.0 Wall_ Wood_ 45.0_ _0.11.0_ -R_11. _R=0.0_ -225.9.0 Wall Wood- 7.9_ _0.11.0_ _RAJ__R=0.0_-31.5__90 Wall- Wood_ 37-7 _0..11.0_ _R_11. _R=0.0_ 4.5__9.0 .Door None_2.4_ _0..5.0.0_ -None- _R=0.0_ 4.5__9.0 Wall_ Wood- 14 _0.11.0_ _R_11. _R=0.0_ 9.0__9.0 Wall_ Wood_ 14 _0.110_ _RAJ. _R=0.0_ 0_ 90 _Roof Wood_ 336_ _0.025_ -R=3.8_ _R=0..0_ 0_ 1.8 Wall_ Wood_ 58_ _0..074_ _R-1.9_ _R=0...0_ _225_ 9.0 Wall- Wood_ 1.63_ _0.0.7_4_ _R_1.9_ _R=0..0_ _31.5__90 Wall_ Wood_ 38_ _0.0.7_4_ -RA-9- _R=0.0_ 4.5_ 90 Total Conditioned Floor Area: 2,188 ft2 Existing Floor Area: 1,852 ft2 Raised Floor Area: 0� ft2 Slab on Grade Area: 2,188 ft2 Average Ceiling Height: 9.0 ft Number of Dwelling Units: 1.00 Number of Stories: 1 # of Thermostat Vent Units Zone Type Type Hgt. Area 1..00_ Conditioned- -Setback- 2 _n/a Gains Condition Y / N Status JA IV Reference Location / Comments IXC IX IXC IXC IX IXC IXC IX IX IX UCSNew ❑Existing- ❑Existing_ ❑Existing- ❑Existing- ❑Existing- ❑Existing_ ❑Existing_ ❑Existing- ❑New ❑New ❑New _01_A17 Existing _0.9=A2 .Existing _0.9=A2 .Existing _0.9=A2 .Existing _0.9=A2 Existing 28=A4 .Existing _0.9=A2 Existing _09=A2 Existing _01_A1.8 Addittion _0.9-A5 � Addittion _09=A5 Addittion _09=A5 Addittion 4.4 by EnergySoft User Number: 5553 Job Number: ADY683-0108 Page:3 of 9 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R PETER & IRNE WATSON 2/4/2008 Project Title Date FENESTRATION SURFACES Window Hgt. Wd. Len. Overhang Hgt. LExt. Left Fin . Right Fin RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 True Cond. Location/ # , Type 0.1 2.0 Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments _L Window- Fso.nt_(SE). 2.0 -3.0-0- _0_650-NF_RC._0.4.0 -NERC 1.3.5_ -9.0- Existing_DEEAULT_DBL-BANE _Existing 2 Window Front (M 40.0 0.650 NFRC 0_40 NFRC 135 90 Existing -DEFAULT DBL PANE Existing 3 Window Rear (NW) 40.0 0.650 NFRC 0_40 NFRC 315 90 Existing_ DEFAULT DBL PANE Existing 4 Window Right (NE) 12.0 0.650 NFRC 0_40 NFRC 45 90 Existing_DEFAULT DBL PANE Existing 5 Window Right (NE) 7.5 0.650 NFRC 0_40 NFRC 45 90 Existing -DEFAULT DBL PANE Existing 6 Window Right (NE) 32.0 0.650 NFRC 0_40 NFRC 45 90 Existina_DEFAULT DBL PANE Existing 7 Window Right_(E)_ THERMAL MASS FOR HIGH MASS DESIGN 10,0 p 650 NFRC 0.40 NFRC 90 -90 Existing_DEFAULT DBL PANE Existing 8 Window Rear( N) 10.0 0.650 NFRC 0.40 NFRC 0 90 Existing_ DEFAULT DBL PANE Existing -9_ Window Rear (NW)_53 3 -Q-3A0-ME-RC 0_28 NFRC 315 90 New BETTER BUILT Vinyl low E Additti0n 1Q Window Rear (NW) 53_30 3A0 NFRC 0.28 NFRC 315 90 New BETTER BUILT Vinyl low E Addittion 11 Window Right (NE) 20.0 0.340 NFRC 0_28 NFRC 45 90 New BETTER BUILT Vinyl low E Addittion 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Len. Overhang Hgt. LExt. Left Fin . Right Fin RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 5.0 8.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 3 0 4-0 -2-0 -QJ 2.0 _2.0 5 Bug Screen 0.76 5.0 1.5 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 8_0 A0 20 -QJ 2.0 2.0 7 Bug Screen 0.76 5.0 2.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 5.0 2.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 6.7 8.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 6.7 8.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 6.7 3.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 162 None No Insulation 26-A1 Existing Existing Slab Perimeter 43 None No Insulation 26-A1 New Addittion Run Initiation Time: 02104108 11:21:11 Run Code: 1202152871 EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY683-0108 Page:4 of 9 Certificate Of Compliance Residential (Part 3 of 4) CF -1 R PETER & IRNE WATSON 2/4/2008 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC Split System Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Existing Setback HVAC DISTRIBUTION Duct Location Heating Cooling Location HVAC Split System Ducted Ducted Attic Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Condition Ducts R -Value Status Tested? 4.2 Existing No WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Standard gas 50 gal. or less Small Gas No Pipe Insulation 1 40,000 50 Existing 0.50 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Pi iinng Length(ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and E of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: ADRIANA GIL Title/Firm: MR. & MRS. WATSON Title/Firm: Adriana Gil Address: Address: 74-854 Velie Way Ste. #8 _ LA QUINTA, CA Telephone: Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) I EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY683-0108 Pane- 5 of 9 1 Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R PETER & IRNE WATSON 2/4/2008 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special Written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Dl— I reia The Existing Water Heater "Standard gas 50 gal. or less" has an EF less than the Table R3-11 CEC Default Vintage Values. The Existing Wall "Wall/Front/SE,43'x9"' has a U -Factor greater than the Table R3-11 CEC Default Vintage Values. The Existing Wall ' Wall/Left/SW,50'x9"' has a U -Factor greater than the Table R3-11 CEC Default Vintage Values. The Existing Wall "Wall/Rear/NW,13.25'x9"' has a U -Factor greater than the Table R3-11 CEC Default Vintage Values. The Existing Wall "Wall/Right/NE,50.25'A has a U -Factor greater than the Table R3-11 CEC Default Vintage Values. The Existing Wall "Wall/FronVE,3'x8"' has a U -Factor greater than the Table R3-11 CEC Default Vintage Values. The Existing Wall "Wall/Rear/N,3'x8"' has a U -Factor greater than the Table R3-11 CEC Default Vintage Values. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a Field EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY683-0108 Page:6 of 9 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑X ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ". ❑ § 1500: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑X ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑X ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El ER 11CF-6R Form: ❑ ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind., 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑, ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 5553 1Job Number: ADY683-0108 Page:7 of 9 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ Q ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 1818 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑X ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑K ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ LXJ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑X ❑ maintenance, and wind. Cellular foam, insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ❑X ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ . b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑X ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGHEFFICACYOUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, El Q ❑ um ehas factory installed HID § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ fx� ❑ OR are controlled by an occupant sensors) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5; Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY683-0108 Page:8 of 9 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE PETER & IRNE WATSON 2/4/2008 SYSTEM NAME FLOOR AREA HVAC Split System 2,188 'STEM Total Room Loads teturn Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts I.OTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 26.0 of 67.9 OF 67.9 of 105.0 OF 1,303 29,130 3,753 831 30,962 O 0 0 cfm 5,855 4,435 0 0 0 0 0 0 0 0 67.9 of 0 5,855 1 4,435 40,841; 3,753 39,833 Carrier 38CKWO6053 43,050 6,352 64,000 Total Adjusted System Output 43,050 6,352 64,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 67.9 OF 67.9 of 105.0 OF Supply Air Ducts Outside Air O 0 cfm Supply Fan Heating Coil 102.9 of 2000 cfm ROOMS 70.0 of 67.9 of . Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 OF 78.8 / 63.1 of 78.8/63.10F 55.0 / 53.7 of Supply Air Ducts O Outside Air 0 cfm Supply Fan Cooling Coil 57.8 / 54.8 of 2000 cfm ROOMS 46.1% R. H. 78.8/63.1 of 76.0 / 62.2 of I Return Air Ducts EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY683-0108 Page:9 of 9 �