Loading...
08-0694 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA 'QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT ~ Application Number: 08-00000694Owner: Property Address: 49893 VIA KATALINA GORNEY THOMAS A k APN: 649-500-014- - - *NOT ON FILE Application description: ADDITION - RESIDENTIAL UNKNOWN," CA 99999 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation:' 9896 Applicant: Architect or Engineer: -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business Professionals Code, and my License is in full force and.effect. License Class: B ZenseNo.: 792381 '4 Date:/714 Contract r. OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to , construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or , that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and • the structure is not intended or offered for sale (Seca 7044, Business and Professions Code: The ' Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( _') I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. • ?09 4, Ouoin000 and Profogoi^n.? C -nn" Thn rnnrrarrnre' 4rats I irense I aw rines not annly to an nwner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). " (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: - LQPEILI4IT [ll Contractor: RISEN CONSTRUCTION 82775 CHARLESTOWN AVENUE INDIO, CA 92201 (760)347-6399 Lic No 792381 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 16/08 e CITY OF W 61UINTA p�CE DEPT.._ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided • for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 229-0025305 _ 'I certify that, in the performance of the work for which this permit is issued, I shall not employ any ' person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should became subject to the workers' compensation provisions of Section 3700 of the Labor Code /,/yyt/Sp'll for wiZcoith those provisions. Date-g9"Applicants/� ' WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND - DOLLARS ($100,000). INADDITIONTO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the cnnditinns and restrictjans set forth 4n this app!ication. 1 . Each person upon whose behalf this application is made, each person at whose request and for ' whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced - within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with. all . city and county ordinances and state laws relating to building struction, and hereby authorize representatives ofthis ty//t9�9�''e ter upon the above-mentioned propert spection pu"r DatefL'L Signature (Applicant or Age p //�_'' �. r LQPERMIT Application Number 08-00000694 Permit . . .. _BUILDING PERMIT Additional desc - Permit Fee . . . . 117.00 Plan Check Fee 76.05 Issue Date Valuation 9896 Expiration Date 1/12/09 Qty Unit Charge Per Extension BASE,FEE 45.00' 8.00 9.0000 THOU BLDG 2,001-25,000 ---------------------------------------------------------------------------- 72.00 Permit ELECT - ADD/ALT/REM Additional desc 173 Permit .Fee 15.00 Plan Check Fee 3.75 Issue Date' Valuation 0 - Expiration Date 1/12/09 Qty .Unit Charge Per Extension, BASE FEE, ---------------- 15.00 Permit . . . MECHANICAL Additional desc . Permit Fee 24.00 Plan Check Fee 6.00 Issue Date . .'. . Valuation . . . . 0 Expiration Date 1/12/09 Qty Unit Charge Per Extension BASE FEE 15.00 1.00` 9.0000 EA MECH APPL REP/ALT/ADD 9.00 ---------------------------------------------------------------------------- Special Notes and Comments CONVERT PATIO TO LIVING SPACE 173 SQ. FT. Other Fees ENERGY REVIEW FEE 7.61 STRONG MOTION (SMI) - RES .98. Fee. summary Charged Paid Credited Due ----------------- ---------- ---------- Permit Fee Total 156.00 ---------- .00 ---------- .00 156.00 Blau Chuuk TuLal 85.00 .00 .00 05:00 - Other Fee Total 8:59 .00 .00 8.59 Grand Total 250.39 .00 .00 250.39 LQPERMIT Bin # City of La Quints • Building & Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building. Permit Application and Tracking Sheet Permit # Project Address: — 03Vtq- 4:f 1 Owner's Name: A. P. Number: 662-166_ Address: V Legal Description: City, ST, Zip: uc 9G-Zsj Contractor:21 SW t ,_ Telephone: Address: _-&S Te Project Description: City, ST, Zip: C olazo , 5 1AI-C Telephone: '76Q) _3-4 No 3 6D-epu '44W State Lic. # :1 �j I 23 D 1 City Lic. #: _ Arch., EnC, Desigae p Address: iS I . City, ST, Zip: Telephone: 066) - 34-00 CM -90'0n Type: Occupancy: State Lic. #: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person:S', t Sq. Ft : # Stories: # Units: Telephone # of Contact Person: 7009?�- S 7St� Estimated Value of Project: APPLICANT:. DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready corrections Plan Check Deposit Truss Calcs. dor Called Contact Pelson Plan. Check Balance Energy Calcs. Plans picked up Flood plain plan Plans resubmitted Mechanical Grading plan 2nd Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. \ H.O.A. Approval Plans resubmitted Grading IN HOUSE: "Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees 51x r 614 P13 APO90Q0W_ �� ,�R >0?40 s l 3 s 0:1f_ °`sem 'eF ��o 1 (570CNc y 117i/ -/S0z .CERTIFICATE OF COMPLIANCE Desert Sands Unified School District Rqo 47950 Dune Palms Road ¢ BERMUDA DUNES O ' - /� `w q W) RANCHO MIRAGE Qetta Date 7/16/08 La u, CA 92253 INDIAN WELLS No. 30133 (760) 771-8515 PALM DESERT `�INDIOTy��y Owner Gorney APN # 602-130-014 Address 49893 Via Katalina Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 Type Residential Addition Lot # No. Street S.F.' • Lot # No. Street S.F. Unit 1 49893 Via Katalina 173 Unit 6 Unit 2 Unit 7 Unit 3 Unit -8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating cr sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 173 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Lucy Ruelas Check No. Name on the check Telephone 347.6399 Funding Exempt By Dr. Sharon P. McGehee « �`. ..� Superintendent '. Fee collected/ xe d by O CGllvrey Payment Recd g�00 y 64r/Under Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this ill serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run frons the date on hich the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another ublic enti authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Do ent NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copw - Accounting CERTIFICATE OF COMPLIANCE: RESIDENTIAL age 1 of s CF -1R Project jOitle r '� s c t t1 rn n, r l`i fir F 1, V V IY Date 4. 17, O y 'p Building Permit tl Project Address 49 -913 v (A, K hr Y A 1 n Q v CA /1 Plan Check /Date Ot or Fa� C�96� SWIMS TWID 76 4.3,;0 S3 Field Cbeck/Date Compliance Method (Prescriptive) pRr S` p I p tlr F— Climate Zone r Enforcement Agency Use Only Alterative Component Package Method: (check one) C X D D (Alternative) Package C and Package D choices require HERS rater field verification and/or diagnostic testing (see CF -1R page 3) For Package D Alternative see Appendix B Table 151-0 Footnotes 8-14 in the Residential ance�Manual=(RI D GENERAL INFORMATION Total Conditioned Floor Area (CFA) 1-13 to Average Ceiling Height: ft Check Applicable Bum Building Type: (check one or more) Single Family Multifamily x Addition `Alteration (If adding fenestration fill-0ut WS -4R, Fenestration Maximum Allowed Area Worksheet and see Section 83.2 for Additions and 8.3.3 for Alterations in the RCM) • Maximum Allowed Total Fenestration Area 35 ft (from WS4R) • Maximum Allowed Wgst Facing Fenestration Area 9 If' W S -4R) • Number of Stories: ! Number of Dwelling Units: la 6/6 • Floor Construction T �Raised Floor (circle one or both) • Front Orientation: 6 North / SouthC�est : All Orientations (input front orientation in degrees from True North and circle one). N RADIANT BARRIER (check box if rewired in climate zones 2 4.9-15) OPAQUE SURFACES INCLUDING OPAQUE DOORS Component Type (Wall, Roof, Floor, siab ridge, Frame Type (wood -Dr-- Location Comments (attic, garage, �1l:-W.� �I■ifiii�i�!�li �I�VANUURW-11�J:L3��■�� n.. - f liWMTW_ i�� ■��� 1) See Joint AMMUlIx J 0R08M* $1 prescriptive Wue to show ence to 2) This colum4 is for the **W4pJ&ieri_ft Residential Comnlia ce Foms 13 Ule rIB616 IOr rlie U-IaCIOr GIIICTMJI. v-txww7 a wu uv► cawcaa December 2005 s r C'O O . 6 H CERTIFICATE OF COMPLIANCE: RESIDENTIAL 2 of 5)- CF -1R Pro jest Title Dente F'EAIE3TRAnO PRODUCTS — 11-FACTM AM SHM FENESTRATION MAXIMUM ALLOWED AREA WORKSHEET WSAR — most be included for New Construction, Additions, and Alterations. 1) Skylights are now included in West -facing fenestration area if the skylights are tilted to the wrest or tilted in any direction when the pitch is less then 1:12. See § 151(f)3C and in Section 3.2.3 of the Residential Manual. 2) Enter values in this column from either NFRC Certified Label or from Standards Default Table I WA. 3) Indicate source either from NFRC or Table 116-A, 4) Enter values in this column from NFRC or from Standards Default Table 1168 or adjusted SHOC from WS -3R. 5) Indicate source either firomNFRC. Table 116B or WS -3R 6) Shading Devices are defined in Table 3-3 in the Residential Manual and see WS -3R to calculate Exterior Shading devices. 'n See Section 3.2A in the Residential Manual. HVAC SYSTEMS Heating Equipment Minimum Distribution Type and Capacity Efficiency Type and Location Duct or Piping Thermostat Configuration (fumace, ham pwqh bodes. do. AFUE - duds oro. R -Value Type e U IS • EX Cooling Equipment Minimiun Type and Capacity Efficiency Distribution (A/C, heat pump, evap. (SEER or Type and Location Cooling) EER ducts ato. Duct or Piping Thermostat Configuration R -Value T lit or Exterior _ Few#/fype/Pos. ShadmgJOverhangsa 7 (Front, Orien- Area U -factor SHOC **'box if WS -3R is i.eft, Rear. Right, tatioq E Wr U -factor' Snurne' SHGC° Sources included S N S O D D D D . D 1) Skylights are now included in West -facing fenestration area if the skylights are tilted to the wrest or tilted in any direction when the pitch is less then 1:12. See § 151(f)3C and in Section 3.2.3 of the Residential Manual. 2) Enter values in this column from either NFRC Certified Label or from Standards Default Table I WA. 3) Indicate source either from NFRC or Table 116-A, 4) Enter values in this column from NFRC or from Standards Default Table 1168 or adjusted SHOC from WS -3R. 5) Indicate source either firomNFRC. Table 116B or WS -3R 6) Shading Devices are defined in Table 3-3 in the Residential Manual and see WS -3R to calculate Exterior Shading devices. 'n See Section 3.2A in the Residential Manual. HVAC SYSTEMS Heating Equipment Minimum Distribution Type and Capacity Efficiency Type and Location Duct or Piping Thermostat Configuration (fumace, ham pwqh bodes. do. AFUE - duds oro. R -Value Type e U IS • EX Cooling Equipment Minimiun Type and Capacity Efficiency Distribution (A/C, heat pump, evap. (SEER or Type and Location Cooling) EER ducts ato. Duct or Piping Thermostat Configuration R -Value T lit or QUETS IN --"-ANY AMC NEW DU December 2005 Residential Comphowe Forms SEALED DUCTS and TXVs (or Alternative Measure%) A si ed CF4R Form must be provided to the building department for each home for which the following are required. ❑ 1 Sealed Ducts all climate zones(Installer testing and certification and HERS rater field verification 17 TXVs, readily accessible (climate zones 2 and 8-i 5 only) Tank External dation R -Value Installer testing and certification and HERS Rater field verification ❑ Refrigerant Charge (climate zones 2 and 8-15 only) (Installer testing and certification and HERS Rater field -Typein verification ❑ Alternative to Sealed Ducts and Refrigerant Charge frxvs (See Package D Alternative Package Features for I Project Climate Zone in the RM Appendix B Table 151-0 Fot*ootes 7-14. no ❑ v No ducts installed ❑ New ducts from existing conditioning e.W4mierit, not exceeding 40ft. in len Tank External dation R -Value For additions and alterations, duct systems that are not documented to have been previously sealed as confirmed Othrough field verification and diagnostic testing in accordance with procedures in the Residential ACM Manual. -Typein Duct systems with more than 40 linear feet in unconditioned spaces shall meet the requirements of Section 150(m) ❑ and duct insulation requirements of Paciaw D. WATER HEATING SYSTEMS r— "l S stems servine sinde dw iup. units (Sae RM Table 5-0, Alternative Water H ' Systems for recireutatioarcqpiremeats Water Heater Distribution T/Fuel Tvve Type Check box if system meets criteria of a "Standard" system. Standard system is one gas-fired water heater per dwelling ❑ unit If the water heater is a storage , 50 gallons is the maximum capacity and recirculation system is not allowed Tank External dation R -Value Check box when using Pteapproved Alternative Water Heating table, Table 5-4 in Chapter 5 in the Residential ❑ Manual. No water heating calculations are required, and the system complies automatically. -Typein Check box if system does not meet criteria of "Standard" system, and does not comply with the Preapproved ❑ Alternative Water Heating table. In this case, the Performance Method must be used and must be included in the submittal. ❑ Chock box to verify that a time control is required for a recirculating stem pump fora system servingmulti le units S stems servine sinde dw iup. units (Sae RM Table 5-0, Alternative Water H ' Systems for recireutatioarcqpiremeats Water Heater Distribution T/Fuel Tvve Type Number in system Rated loptat (kwu, Bbow) Ertey ' Tank Factor or Capacity Tl:iennal may' (gonm)Efficiency Loss o Tank External dation R -Value Energy ��Y Factor' or T Efficiency Standby Loss o Tank External Insulation R -Value -Typein Yl!r. Axl h Cvetwn eprvino multinle dwellino units )Sen Residential Manual Seetinn 5331 Water Heater Distribution Number System Rated lnpwr (kw or Btaft Tank Capacity Energy ��Y Factor' or T Efficiency Standby Loss o Tank External Insulation R -Value -Typein h N l) For small gas storage water boaters (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance, and had pump water heaters, list Energy Factor. For large gas storage water banters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency, Thermal Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Thermal Efficiencies. HIM Insulation (kitchen lines >_ 3/4 inches) All hot water pipes from the heating source to the kitchen fixtures that are % inches or greater in diameter shall be thermally insulated as specified by Section 150 V) 2 A or 150 (1) 2 B. Residential CompUance Forms December 2005 . CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page a of 5) CF -1R lndioate which spacial features are pmts of this pmjed. The list below only represents spccial featrues relevant to the presc nptrve method. Category Bdidbng Olfialal V tion of Special Features HERS Rater Verification HERS Rater Diagrrostk Tesbrg Measure Dads ❑ Y 100% of ducts in t 0 Y Buried ducts ❑ Y Diagnostic supply duct locsation, surface area. and R -Aha Y Duct" , , R -value ❑ Y Dud leakage Y Duds inattic with radim tmrriers ❑ Y [.ass than 12 it. of duct outside conditioned space ❑ Y Non-standard duct location 0 Y Supply registers wilm two ft of floor 0 Ernebpe ❑ Y Air retarding wrap ❑ Y Coal root ❑ Y Exterior shades ❑ Y High thermal mass 0 Y Inter con a vendladon ❑ Y Metal framed wafts 0 Y Non4e1au/t vent hel" ❑ Y Quality iri ubdon betallabon Y Radiant barrier ❑ Y Reduced Mftabw (blower door). May also tegrdre medwdcal ver dation. ❑ Y Soar gain targeft (far sunspaces) ❑ Y Surspaoe with hterzane surtaoes ❑ Y Vent area greater than 10% 0 HVAC EgetpneW ❑ Y Adequstealrtlow ❑ Y Air oomdit o m sae ❑ Y Air handler tan power ❑ Y HOEER ❑ Y Mrdraic heating 6yateme 0 Y . #Iteananical venbtebon 0 Y age 0 Y Thenmostedc mWar+sion vahm MM ❑ Y Zonal control Water Planta ❑ Y Combined hydrddc 0 Y High EF forezis"wrater heaters 0 Y Non-NAECA wager heater 0 Y Na► -standard water heaters (Whhnit) ❑ Y Water heater dlstrlbreion credits Residential Compliance Forms December 2005 • CERTIFICATE OF COMPLIANCE: RESIDENTIAL (rage s of 5) CF -1R Project Title v Date • 12-0 2,O Special Remarks COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24,.. Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TX's, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Desioner or Owner (ver Business and Professions Code) Documentation Author G `UL I�EL�o�.l err DAVIO ILLIGrT r 1�R6Y Title/Firm: E l,. o tA 1*5 I Tido/Firm: SGaVIC�S _ Address 1 I Address: 90 i 3 SV L 81 PPIE a Y VICOIV1 U,c , c A Telephone License #: (if a bk) Rn -03-i Z C L A ZZ (signature) (date) (sigoawre) (date) Enforcement Agency til== Title Age�W Telephone (si oure / date Rb!r A. E=TT Residential Compliance Forms December 2005 FENESTRATION - MAXIMUM ALLOWED AREA WORKSHEET WS -4R Project Title c om g� 7Daw 4-12,04 FENESTRATION PRODUC'T'S — NEW CONSTRUCTION- NEW BUILDINGS ­'- _ • c 1 a...:l.t:.... 44 ..P F e4.nfinn UM; 4113 WVlc &VI T. waauaa A B C - D - ---- -- E F G wrype/Pos_ (Front, Left. Rear, Right, S Orientation Total Fenestration, West Facing Area ftZ Total Fenestration for N, S, E Orientation Area ft CFA Total Percent of West Fat Fenestration C x 1(0% Total % of Fenestration Inalttding West x 11700/a + F North Total % of Fenestra - fM 2. % 4 /C x 100% R SA R North Removed Orientation 1 South Proposed installed New Area ft2(C-114G) East South West East North west Totals South South 1) if west facing area exceeds 5o/s of CFA in climate zones 2, 4, and 7-15, tic panormance approach must are useu. 2) If total pen mt of fenestration exceeds 200A including West facing orientations then performance approach must be used. West facing area includes skylights tilted to the west or tilted in any direction when the pitch is lose than 1: t2 for Package D only. FENESTRATION PRODUCTS — NEW CON U ION- ADDITIONS ✓ nr — #han 1fln AZ Sri sae than nr Fturnl to lnnn f? ❑ Greater 1000 ill A B C D E F -3 H q/rypwpb& (Front, Left, Rear, Right, Skylight) Orients- tion Proposed Proposed Addition's Addition's Fenestration CFA1, X 3 Area (fe' Fenestration Area Removed to make way for Addition Total Area Added Fenestration D - E Total % of wca Facing Fmegration1 GIC 100-4 Total % of Fenestra - fM 2. % 4 /C x 100% R SA R North Removed Orientation 1 2 Proposed installed New Area ft2(C-114G) Total Net Fenestration (ft2) South East North west South South South Total 1) Additions <100 sf are allowed to install up to 50In of fenestration and are exempt from the 511A west lacing and Mo maximum total area limits and shall meet the U-&cw and SHGC requirements of Package D. See Table 9-2 in the Residential Manual. Nolu: Leave columns E, F, G, H, and I blank. 2) Additions <1000 M, the maximum net allowed fenestration is 209A end may be increased additionally to by the amount of glazing removed in the wall that separates the addition from the existing house. However, the total Wen facing finestratioa can not exceed 5% of the proposed addition's CFA including skylights orientated in any direction and tilted with a pitch of < 1:12. Column G can Sot exceed 5% and Column H can not exceed 20%. 3) Additions > 1,000 W, must meet Package D requirements. See Table 9-2 and Table 151-C in Appendix B of the RM or use Performance Approach. 4) The 5'Yowest orientation restrictions are only for Climate zones 2, 4, and 7-15; for Climate Zones 2,4 and 7-15 cater sero (0) in column E. FENESTRATION PRODUCTS: ALTERATIONS Use this table for alterations to an existins btu where heaestrattans Xrommts wmaows are cam ruumvcu aaaurur auueu B C D E F G H I rA Existing Existing Area Orientation Removed Orientation Removed Arts (ft2) Proposed Installed Orientation Proposed installed New Area ft2(C-114G) Total Net Fenestration (ft2) Total %of Fencstra-tion'-= (H/A) x 100% Max of 20% North North North South South South East East East west West west Total Total Total 1) When 50 f or more of fenestration area is added to an existing building, then the tenesbanon must meet me :ugwtemmts of rw mgo u. 2) The area requitement for the total fenestration area for the whole building, including the added fenestration, unad not exceed 20%. Otherwise, the Performance Approach must be used. See Section 93.3 in the RM for farther details. Residential Compharice Forma December 2005 MANDATORY MEASURES SUMMARY: RESIDENTIAL (Page 1 of 2). W -1R 4, t2 Project Title A O RN Cy Date Note: Low-rise residential buildings subject to the Standards most contain these meantttos regardless of the compliance approach used. More stringent compliance requirements Som the Ceftificate of Compliance supersede the items marked with an asterisk (7 below. When this checklist is incorporated into the permit domments, the featn w noted shall be considered by all patties as minimum compoomt performance specifications for the mandatory measures whether they are shown elsewhere m the documents of on this checklist only. Ins"ctions: Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. DESCRIPTION )VA B of Building Envelope Measures: ✓ ✓ ✓ 1 L • §I 50(a): Miaim>w 9 is wood fi®e aa7ing iossi>►tion agaivalmt``U-fistar m metal ft�c oeog.�Z 7 p ❑ JO ❑ §150 ): Losse fill insulaaion msaefecturves labeled R-Valoe: Q 3 O ❑ ❑ • §150(c): Minimum R-13 wall insolation in wood framed walls or cOvdcat U-feam in metal frame walls (dace not eppty exterior mass walla ❑Iv1 iM 13to • §150(d): Minimum R-13 raised floor ®solation ® framed fioma oregeiwlmt U -f `O-- ❑ 1 ❑ §150(0): Installation of Faepteaa, Decorative Gas Appliances and (1se Loge. 1 _ Masonry and faatory4sailt faspleocs have: a. closeable metal or glass door covering the entire opening of the fuebox to� sf+ ❑ ❑ b, outside air intake with deeper and eaand. floc damps and control . ❑ ❑ 2. No continuous binning gm palm ligbts. aDosrcd ® ❑ ❑ §150(1): Air retarding wrap installed to comply with §151 me cU requirememta Specified in the ACM Residential Manual. �] ❑ ❑ §150(8): Vapor barriers mandatary in Climate Zona 14 and 16 only. ❑ AN ❑ §150(1} Slab edge insulation - wow absorption rate for the insulation malarial alone without facings no greater that 0.3% water Vapor a roto no greater than 2.0 mote. ❑ ❑ §1 IS: Insulation specified or installed meats insolation installation quality standards. Indioale type and include CF -6R Farm: ❑ ❑ §116-§117: FmesOrsAiae Aodaab, E:lcriorpoms, sed Caafmla. 1. Dome and windows between conditioned and unconditioned spaas designed to limit air leakage. ❑ � ❑ 2 Fenestmbea produob (accept field-fabriadod) have label with omtified U -factor. catitied Solar Had (lain Codiiciwt (mwcl and iambanon amtifiost m. ❑ 1 ❑ 3. Ederior dome sad wiadowa vRatheavtrtpp0d; e!1}oiats and peaetratioos aanikod and sealed ❑ tl ❑ Space Conditienlo& Nater Heaft and Pbnnabbleg System Meawres: §110-§113: HVAC wales heatars. ahowah®b and fa soela cattified by rho Enargy Commission. ❑ ❑ §150(bk Heating and/or cooling loads calculated in so= _1 with ASMAE, SMACNA or ACCA; .® ❑ ❑ §150(i)c Setback stat an all applicable heating and/or owlmg systems. to ❑ ❑ § I SO jX Water system pipe and tank insolation and cooling systems line insulation. 1. Storage sae water beadcre riled with an Energy Factor las than 0.59 mug be mstemally w+appM with insoldian boviaR an installed thermal raietaaoc of R-12 or 10 ❑ ❑ 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hal water tanks have R 12 axternal insulation or R-16 internal iesu4tion and indicated an the extcricr of the tank showing the R -value 50 ❑ ❑ 3. The following piping is insulated according to Tubb 150-A/B or Equation 150-A insulation Thickness: 1 _ First 5 feet of hot and cold water pips cicsent to water hater tank, nowicuiscubding systems, and catire Iwo Of recirculstina sections of hot water pipes. shall tee insaLteid to Table 150B. ❑ ❑ 2 Cooling aystem piping (motion, dulled water, or brine lineal piping maulded be m heating somoo and indirect hot water tank shell be insulated to Table 150•B and Equation 150-A. ® ❑ ❑ 4. Steam hydronic heating systems or hot water systems >15 poi, meet fcgmomenb of Table 123-A C) 13 Residential Compfiance Forms December lvu.) MANDATORY MEASURES SUMMARY: RESIDENTIAL P I of 2) -1R DESCRIPTION NA F Desla. Spam Condiflonkr. wakr Hadkig sed Pkmbbg S NW=on&' too■ ve v S. Insulation must be pt dea0ed Som damage, including that due to sunlight, moisture, equipment maintenance, and wind ® ❑ ❑ 6. Insulation for ehaw wator piping and rcf igcn at auction piping moludee a vapor ntardmt or a enclosed entirely is conditioned ❑ ❑ 7. Solar water-heating systems/collcotose we certified by the Solar Rating and Carfification Corporation est qt ❑ ❑ • §150(m): Deets and Faro I. All dmots amd pima m osufled, sadodand iosddod to mod the roquiemet ofthe CMC Saotiam 601, 602, 603, 604, 605 and Standard 6.5; sapplyra& and retu .rah ducts and pkmms aro insulated to a minimum memlled {oval of R-4.2 or malcsed adzub is conditioned speoa Openings shah be scoledwith meatm, aPe or ether daAAAawn system that meets the ❑ 5P ❑ applied& rerpiemeaIs of UL ISI, UL ISI A crUL I8IB oraoosd outset the encs' &croquimmcmb cfUL 723. N mastic or tape is used to seal than 114 inch, the combination of maabc and c;thermash of We shall be am& 2. Building cavities, support platforms for sir handlers, and plenums defined or constructed wish materials other than sealed shed metal, duct board or fieaibla dont shall not be used for conveying conditioned air. Building cavitis and ❑ pl 13support pldfams may contain ducts. Ducts instellod in cavitas and support platforms shall not be compressed to wase 9' teduntions is the asoss sctiond soca of the doob. 3. Joints and enema of dant systems and their components shall act be waled with cloth bank robber adhesive deaf tapes ❑ s4 7� ❑ unk-as such tape is used to combination with m ostio and draw bands. 4. Exhaust fam systems have back dradt or antomatio dampers. ❑ Q1 ❑ S. Gravity ventildm8 systems serving conditioned space have ether aotomatic or readily aoosaiblc. manually operated 013damp— W Ptotoctien of Insulation. Insulation shall be protected fiom damage, including that dere to snnligbt, moisture, equilment ID ❑ maintananoe, and wind. Cdllulw foam insulation shall be pretootod as above at punted with a coating that is water ❑ rdardaet and pfavides shielding fi en solar radiation that am noose devadation of the material. 7. FlcmW ducts cannot have parous moor cors. ❑ ❑ §114: Pod cad Spa Bating Systems and Eip ipmmt. 1. A thermal eflicionoy that oomphis with the Applianco Efficiency Rogolations, on-off switch mounted outside of the pl ❑ ❑ Looter f gperefing matructioae so eloatrio resistance haslang and no Flat light1OM 2. System is installed with: a. at least 3G ofpipe bcWm Bier and heater far future solar Treating ❑ b. Goya for outdoor Ponta or outdoor spm ❑ ❑ 3. Pool system has dimatiomal 'inlets and a circulation pump time switch. ❑ ❑ §I 1 S: Gas fired fm-type, central foreaces, pool heaters, ops hostas err bousahold 000king appliances have oro ooatiauduly pt ❑ ❑ 4� Unuma pilot light (Exception: Noo-eleatrioa) cookina appliences with < 150 BhAr §118(i): Cool Raaf material meets specified criteria ❑ ❑ ResldentW L10tWX Mt:tla m: §150(k)l: HIGH EFFICACY LUMINAIRES OT ER THAN OUTDOOR IIID: contain only high efficacy tamps as outlined in Table 150.0, and do not contain a modium screw base socket (E24/E24 Ballast for IBM" 13 watts or greater ❑ i in ❑ are ebdtrank and have an output fingmency no less than 20 kHz 6150(k)l: HIGH EFFWACY LUMINAIRES - OU7DOOR IBD: cambia only high efficacy lamps s audiand in Tubb ❑ la ❑ 150-0 h muncre has factory installed HID balad §t 50(k)2: Pmmanemtty imatallad has inair= ins kitah m shall bG high affieaey lumiubm. Up to SO psoant of the wattage, ore determined in § 130 (o), of permanently installed luminaires in lotahcas may be in luminaires that aro not high efiiowy ❑ ❑ lummaima, provided that thse hmamames are Gontrolod by ewitdm separm from those controlling rho high offwaoy luminaires. §150(k)3: PermamenQy installed hnnmauo in bathrooms, gar"n, Landry rooms and atility roams @hal be high cffioaay ❑ ❑ lumrimairm OR we oontmBW by an 000npant mmor(s) omtidied to comply v4ffi Section 119(d)that does.net turn on 12 automabcally or baro am always on I §150(k)4: Permanently installed lu n mai ca located other thus in kitchens, bathrooms, gangs, Laundry scams, and utility mama shall be high effioavy luminaires (oxoept closets less thmn 7011'): OR an camLouad by a dimer switch OR we ❑ ❑ Gontroltcd by an occupant semsar that complies with Section 119(4) that does not ran on amtamahcally or have an always on option. §I 50(k)S: Luminaires that are fawned into insulated cailimgs are agipewed for mo clearance insulation cover (IC) and are ❑ V If certified to ASTM E283 and labeled as airtiAl)to tae than 2.0 CFM d75 Pascals. §I50(k)6. L_hksir_ providing outdoof 6gEdmg orad permanently mounted to a residential huitdmg or to other buildings on The same lot sbal be high efficacy heninaius (mot incbd'mg lighting amend swimming pools/wata team= or dhcr ❑ OP ❑ Article 680 locations) OR we controlled by owepent am= with iatcgral photo ocetrd certified to aasply with Section it d § I50(k)7: Lighting for parking lata fon 8 or mac vehiols shall have lighting that complies with Sao. 130, 132, and 147. ❑ ❑ Lighting for parlang garagn for 8 or more vehicles shall have fightingthatcomplies with See. 130, 131 and 146. §150(k)R: Permanently instated lighting a the racked, eoo-dwcWmg spaaaea of low-rise residential buildings with four or more dwclmg unite shall be high drWacy luminaires OR we eontroBed by ooeoped scumn(s) oafified to comply with ❑ ❑ Section 1I d Residential Compliance Forms December 2005 Page 3-34 - Building Envelope Requirements — Insulation 3.3.3 Radiant Barriers Radiant Barrier Requirements §151(02 The prescriptive requirements call for a radiant barrier in climate zones with significant cooling loads (2, 4, and 8 through 15). The radiant barrier is a reflective material that reduces radiant heat transfer caused by solar heat gain in the roof. Radiant barriers reduce the radiant gain to air distribution ducts and . insulation located below the radiant barrier. In the performance approach, radiant barriers are modeled as separate adjustments to the heating U -factor and the cooling U -factor. The duct efficiency is also affected by the presence of a radiant barrier, with the performance approach. Radiant Barrier Construction Practice To qualify, a radiant barrier must have an emittance of 0.05 or less. The product must be tested according to ASTM C-1371-98 or ASTM E408-711(2002) and must be certified by the Department of Consumer Affairs2. Radiant barriers must also meet installation criteria as specified in Section 4.2.1 of the Residential ACM Manual (Section 4.2.1 is also reproduced in Appendix D of this document). The most common way of meeting the radiant barrier requirement is to use roof sheathing that has a radiant barrier bonded to it in the factory. Oriented strand board (OSB) is the most common material available with a factory -applied radiant barrier. The sheathing is installed with the radiant barrier (shiny side) facing down toward the attic space. Alternatively, a radiant barrier material that meets the same ASTM test and moisture perforation requirements that apply to factory -laminated foil can be field -laminated. Field lamination must use a secure mechanical means of holding the foil to the bottom of the roof decking such as staples or nails that do not penetrate all the way through the roof deck material. Other acceptable methods are to drape a foil type radiant barrier over the top of the top chords before the sheathing is installed, stapling the radiant barrier between the top chords after the sheathing is installed, and stapling the radiant barrier to the underside of the truss/rafters (top chord). For these installation methods, the foil must be installed with spacing requirements as described in Section 4.2.1 of the Residential ACM Manual.. The minimum spacing k requirements do not apply to this installation since it is considered a "laminated" system. Installation of radiant barriers is somewhat more challenging in the case of closed rafter spaces when sheathing is installed that does not include a laminated foil. Foil may be field -laminated after the sheathing has been installed by "laminating" the foil as described above to the roof sheathing between framing members. This construction type is described in the Residential ACM Manual, Section 4.2.1. See Figure 3-12 for drawings of radiant barrier installation methods. 2 Certification of radiant barriers is required by CCR, Title 24, Part 12, Chapter 12-13, Standards for Insulating Material. 2005 Residential Compliance Manual March 2005 ' ~ Building Envelope Requirements — Insulation Page 3-35 �:::: :::':f;;:;:: CiJ ........................................................:::::::::::::::::::::::::::::::::::::::::::::: iiiir'2l7) C1it 7 •: s`•��:F2ozif;::;`:�:................................. ..... itaS,e:..............................J.�............................................. I .....::::::::::::::::::::::::::: i; Etatles : r.::..:................................r-::::::::::::: :::::......,,_ . ___........................:..:.:.::..1...:::::: .........::::::.;:.;:.: Ovei ... o:::w A.ia..Fii:tJ Figure 3-12 — Methods of Installation for Radiant Barriers 3.3.4 Wall Insulation Mandatory Measures The man ory measures require that wood -framed walls above de have at least R-13 in tion installed in the cavities between the fra g members. However, the pre . tive measures for Alternative Com ent Package C requires more insulati han the minimum requirem s in all climate zones. Likewise, Alternative Comp ent Package D re ' es more insulation than the minimum requirements in clima ones 1 11 through 16. Wall constructions with insulation tha of penetrated by framing members, or with metal framing, comply with t ' manda measure if they have a U -factor lower than 0.102, which is th -factor of a woo - med wall with R-13 insulation. Entry A3 in Ta IV.9 in Joint Appendix IV f e basis for the U - factor criterion. Insulation may b f greater insulating value in certain areas of the II and of lesser insulati value in other areas of the wall provided that the area- eighted U -factor do not exceed 0.102 to show equivalence to an R-13 wall. 2005 Residential Compliance Manual March 2005 'fp�l�tEii, ...... ..... :.. .... ».....:.. rriEt.I7r8Fsi{ �iul�tl f Ti WVia;fer ... o:::w A.ia..Fii:tJ Figure 3-12 — Methods of Installation for Radiant Barriers 3.3.4 Wall Insulation Mandatory Measures The man ory measures require that wood -framed walls above de have at least R-13 in tion installed in the cavities between the fra g members. However, the pre . tive measures for Alternative Com ent Package C requires more insulati han the minimum requirem s in all climate zones. Likewise, Alternative Comp ent Package D re ' es more insulation than the minimum requirements in clima ones 1 11 through 16. Wall constructions with insulation tha of penetrated by framing members, or with metal framing, comply with t ' manda measure if they have a U -factor lower than 0.102, which is th -factor of a woo - med wall with R-13 insulation. Entry A3 in Ta IV.9 in Joint Appendix IV f e basis for the U - factor criterion. Insulation may b f greater insulating value in certain areas of the II and of lesser insulati value in other areas of the wall provided that the area- eighted U -factor do not exceed 0.102 to show equivalence to an R-13 wall. 2005 Residential Compliance Manual March 2005 Merrell-Johnso n.. Engineering, Inc. CIVIL ENGINEERING ♦ SURVEYING June 26, 2008, City of La Quinta Building and Safety Department . RE: Plan Check No.' 08-694 Gorney Residence -Remodel 49893 Via Katalina La Quinta, CA; MJE Job #3037 To Whom It.May Concern: The following addresses structural plan corrections for the 'above mentioned project. Plans resubmitted. -/2. Correction list responded to. ,/3. Noted on Framing.Plan, Sheet 3; ✓4. Noted on Framing.Plan, Sheet 3." Noted: on Framing Plan, . Sheet '3. �6...Noted\on Framing Plan, Sheet 3. D'etail 1 as shown on sheet D3 has been modified to show boundary railing of both;proposed and existing -locations as well as the existing blocking. Additionally - the ledger is shown as being attached to the existng,blocking with 16d nails @ 6" ' o:c. staggered. _ Shearwall holdown design of STHD 14 per ICC Evaluation Report numbers .5275 and .5349: Spacing o a1,1 c. o'r'b�iis walls determined by. 2005 NDS: and ACI 318, Appendiix'1. Y, Op BUILDING & SA QUINTq Please contact us if they are ?Y pEpr. FOR ,C VEE T Sincerely, I UCrioN -. DA Y Merrell -Johnson Engineering,. nc. 10, /,B S. Merrell, PE JUL Q 3 200.8 Principal JBy 12138 Industrial Blvd., Suite 240 • Victorville, CA 92395,• (760) 241-6146 • Fax (760) 241-0566 . 128. E. Fredricks St. • Barstow; CA 92311 • (760) 256-2068 • Fax (760) 256-0418 City of La Quinta Building and Safety Department Structural Plan Correction Gorney Residence -Remodel Plan Check No.: 08-694 49893 Via Katalina Engineer: E. Cary Packer :La Quinta, California Status: 1" Check Resubmit redlined plans for next review. Failure to resubmit these plans may cause delays, a new review, and/or additional plan review fees. Respond to each of the below items with a written commentary as to where and how the requirement was met. Respond to redlined items on structural plans. Nails and other fasteners in pressure treated sill plates shall 'be zinc coated =-iot dipped galvanized as specified in CBC 2304.5.9. SEE. aoTE 0 8 ow Strr 3 Provide the following note on plan: Wood required by Section 2304.11 to be preservative treated shall bear the quality mark, of an inspection agencies that maintains continuing supervision, testing and inspection over the quality of the preservative treated wood. The quality mark sha=t be on a stamp or label affixed to the preservative -treated wood, and shall include the following information: a. Identification of treating manufacturer. 5 E E wloTE 4V 9 014 S►1T'. 3 b: Type of preservative used. c. Minimum preservative retention (pcf). d. End use for which the product is treated. e. AWPA standard to which the *product was treated. f. Identity of the accredited inspection agency. Specify on plans that structural observation per CBC 1709.2 is required. Nate this in the structural notes or on framing plan. SEE, IU -M *t b crA � -3 Note on plans periodic special inspection for wood as per Section 1707.3. Stir, AOTE II OW SNT.3 �! Verify. if (2)-16d per truss is adequate for shear transfer in 1 /D3. Specify boundary nailing. as well. Z>K EAG ..►EER Ue TER SW D3 'DUAIL 1 .�$ . Provide shear wall hold-down (STHD14) design. All shear wall anchor bolts shall be designed as per ACI 318, Appendix D. 5EE Ea 6 i WEEP- L Vq*r. . If corrections require revisions to the structural calculations, provide one complete copy of the redlined calculations from this submittal plus two complete, bound copies ofthe revised calculations for review and approval Providing only a few supplemental, rerised pages will not be accepted and will delay approval of this project Additional corrections may be requested upon subsequent reviews. If you have any question, please call Plan Checker. M. McElroy Phone (760) 360-5770 ext. 105