12-0796 (SOL)P'.-O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 12 -00000796_ - Property Address: =49924__ VIA _KATALINA APN: 602-160-027- - Application description: SOLAR Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 9579 Applicant: Architect or Engineer: ! i 4SGV- (00,� VOICE (760) 7C 012 FAX (760) 777-70 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 8/27/12 Owner: MASTER ASSN FOR RANCHO C/O JACKSON DEMARCO & P O BOX 19704 IRVINE, CA 92623 Contractor: -REVCO SOLAR 26631 CABOT LA QUIN PECKENPA ENGINEERING ROAD SUITE LAGUNA HILLS, CA 92653 (949)367-0740 LiC. No.: 387219 LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION - I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with. 1 hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of theMuioess and P�fee sionals Code, and my License is in full force and effect. I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: B CIO C46 Date: OWNER -BUILDER DECLAPATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)•: (_ I I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ I I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY - I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 9003164-12 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any er so as to becor^subject to the workers' com sat ion laws of California, and agree that if I s uld become s bj ct t the workers' compen ti provisions of Section `0 of the La C , I shall fort w' h ly w' h tho a provis n . Date: i Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAG IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is, hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and statet he above information is correct. I agree to ply with all city and county ordinances and state laws relating o bw ing construcilkn, and ereby authorize r re entatives of this co my Jo enter upon the above-mentionedropert for inspect n urp Date: Signature (Applicant or Age ntl: Application Number . . . . . 12-00000796 Permit SOLAR PERMIT Additional desc . Permit Fee . . . . 22.50 Pln Check Fee 5.63 Issue Date . . . . Valuation 9579 Expiration Date 2/23/13 Qty Unit Charge Per Extension., BASE FEE 15`.00 1.00 4.5000 'EA SOLAR COLLECTOR < 1000 4.50 1.00 3.0000 EA SOLAR EQUIP MISCELLANEOUS 3.00 Permit ELEC-MISCELLANEOUS Additional desc . Permit Fee . . 18.75 Plan Check Fee 4.69 Issue Date Valuation . . . . 0 Expiration Date 2/23/13 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 .75 1.0.0 3.0000 EA ELEC PWR APP <=1 3.00 Special Notes and Comments SOLAR POOL WATER HEATING SYSTEM - 576SF COLLECTOR, ELECTRICAL CONTROL, 15A/240V BOOSTER PUMP AND PIPING TO EXISTING POOL PLUMBING. ALL COLLECTORS ATTACHED TO ENGINEERED CARPORT STRUCTURE, PERMIT NO. 12-0691. 2010•CALIFORNIA.BUILDING CODES. August 27, 2012.4:52:49 PM AORTEGA --------------- ------ ------------------------------------------------------ Other Fees - . . . BLDG STDS ADMIN (SB1473) 1.00 Fee summary Charged Paid Credited Due Permit Fee Total 41.25 .00 .00 41.25 Plan Check Total 10.32 .00 .00 10.32 . Other Fee Total' 1.00 .00 .00 1.00 Grand Total -`• 52.57 .00 .00 52.57 LQPERMIT PfaPC17 SUNSAVERv,-4A� SOLAR HEAT EXCHANGER DESCRIPTION:, The SunSaverTM Solar Collector is manufactured in Chico, California. The collector is a specially developed, highly stabilized polyolefin and is of parallel, circular channel design. It is unglazed, un -insulated, and designed for low temperature applications such as swimming pool heating, heat pumps, aquiculture, and hydroponics. DIMENSIONS: Header Length = 50.875 in. (1.29 m) Width (Panel body) = 47.5 in. (1.21 m) Overall Dimensions Effective Area 4ft. X 8 ft. (1.22 X 2.44 m) 31.6 (2.94 m) 4 ft. X 10 ft. (1.22 X 3.05 m) 39.5 ft2 (3.67 m2) 4 ft. X 12 ft. (1.22 X 3:66 m) 47.8 ft2 (4.40 m2) ROOF MOUNTING SPACE: Width = (Number of panels X 50.875 in. (129 cm)] +24 in. (61 cm) Length.= Panel length + 24 in. (61 cm) RACK SPACE: Width = (Number of panels X 50.875 in. (129 cm)]+2 in. (5 cm) Length = Panel length + 6 in. (15 cm) FLOW: Maximum recommended flow = 8 gpm per panel 3.47 psi head loss (1,817 I/hr, 0.244 kg/cm2) Minimum recommended flow = 3 gpm per panel 0.48 psi head loss (681 I/hr, 0.034 kg/cm2) Recommended flow = 4 gpm per panel 0.87 psi head loss (908 I/hr, 0.061 kg/cm2) PANELS PER BANK: 12 panels single end feed (maximum) 17 panels .diagonal feed - PRESSURE:, NORMAL OPERATING MAXIMUM INTERMITTENT, PRESSURE PRESSURE 80°F (27°C) 0 to 30 psi45 psi (0 - 2.11 kg/cm2) (3.16 kg/cm2) 212°F (100°C) 0 to 5 psi 5 psi (0 - 0.35 kg/cm2) (0.35 kg/cm2) 70°F (21°C) Measured burst pressure of panel body = Over 300 psi (21.1 kg/cm2) TEMPERATURE: Normal operating temperature = 60°F to 90°F (16°C to 32°C) Maximum continuous operating temperature = 212°F (100°C) Maximum intermittent temperature (un -pressured) = 250°F (121°C) Melt temperature = 338°F (170°C) CHEMICAL RESISTANCE: Compatible with common collector fluids CORROSION: Non -corrosive FREEZING: The system should be drained before freezing conditions occur. WEATHERABILITY: Weatherometer, accelerated outdoor exposure, and other extensive laboratory testing demonstrates long-term weatherability of SunSaverTM collectors (see warranty). Additionally, FAFCO's experience of 30+ years and over 1,000,000 collectors installed confirms that the proprietary stabilization and high mechanical strength results in negligible warranty over the TWELVE-YEAR warranty period. ABSORPTIVITY: 0.96 EMISSIVITY: 0.90 TIME CONSTANT: 64 seconds TESTED OUTPUT: 1,014 BTU/ft2 (Florida Solar Energy Center) PERFORMANCE CURVES: MEASURED EFFICIENCY INCIDENT ANGLE Average flow rate 4.9 gpm (1113 Vhr) CHARACTERISTICS Average wind velocity 2.4 mph (3.9 km/hr) 1.05 1 W z X 0.95 <W W U 0.9 D � U 0.85 0.8 1 I 0 0.2 0.4 0.6 0.8 1 (1/(COS INCANG))-1 PRESSURE vs. FLOW 8 y 6 d 04 J Q x 2 0 90 so 70 > 60 U Z 50 LL u 40 W 30 20 10 0 0.80 > 0.70 U Z W U W 0.60 0.50 0 1 2 3 0 1 2 3 4 5 6 7 8 FLOW RATE (gpm) FLOW RATE (gpm per panel) All specifications and dimensions set forth above are as estimated by FAFCO Inc., but are not intended to be precise and should not be relied upon as precise without independent verification. These estimated specifications and dimensions are subject to change without notice. Nothing contained herein is intended or should be construed to expand or extend FAFCO Inc.'s warranty, or establish any express or implied warranties of any nature, other than as contained in the Twelve Year Warranty Agreement. (FAFCO Inc. disclaims any other warranties and assumes no duty to provide notice if it becomes aware of any deficiencies in these estimates.) The reader accepts full responsibility for any use or application of these estimates and specifically understands and acknowledges the limited reliability of these estimates. 0 0.05 0.1 0.15 0.2 0.25 0.3 (Ti-Ta)/I (F sgfl hr/ffn ) EFFICIENCY vs. FLOW (for typ. conditions) Additional test data available on request P/N 06359G 09/06 4 y w t WEIGHT: Without Water: 4 ft. X 8 ft. 13.5 lbs (5.04 kg) or 0.42 lbs/ft2 (2.05 kg/m2) 4 ft. X 10 ft. 15.9 lbs (5.93 kg) or 0.40 lbs/ft2 (1.95 kg/m2) 4 ft. X 12 ft. 18.3 lbs (6.83 kg) or 0.38 lbs/ft2 (1.86 kg/m2) With Water: 4 ft. X 8 ft. 51.1 lbs (19.1 kg) or 1.60 lbs/ft2 (7.81 kg/m2) 4 ft. X 10 ft. 59.8 lbs (22.3 kg) or 1.50 lbs/ft2 (7.32 kg/m2) 4 ft. X 12 ft. 68.5 lbs (25.6 kg) or 1.43 lbs/ft2 (6.98 kg/m2) ABSORPTIVITY: 0.96 EMISSIVITY: 0.90 TIME CONSTANT: 64 seconds TESTED OUTPUT: 1,014 BTU/ft2 (Florida Solar Energy Center) PERFORMANCE CURVES: MEASURED EFFICIENCY INCIDENT ANGLE Average flow rate 4.9 gpm (1113 Vhr) CHARACTERISTICS Average wind velocity 2.4 mph (3.9 km/hr) 1.05 1 W z X 0.95 <W W U 0.9 D � U 0.85 0.8 1 I 0 0.2 0.4 0.6 0.8 1 (1/(COS INCANG))-1 PRESSURE vs. FLOW 8 y 6 d 04 J Q x 2 0 90 so 70 > 60 U Z 50 LL u 40 W 30 20 10 0 0.80 > 0.70 U Z W U W 0.60 0.50 0 1 2 3 0 1 2 3 4 5 6 7 8 FLOW RATE (gpm) FLOW RATE (gpm per panel) All specifications and dimensions set forth above are as estimated by FAFCO Inc., but are not intended to be precise and should not be relied upon as precise without independent verification. These estimated specifications and dimensions are subject to change without notice. Nothing contained herein is intended or should be construed to expand or extend FAFCO Inc.'s warranty, or establish any express or implied warranties of any nature, other than as contained in the Twelve Year Warranty Agreement. (FAFCO Inc. disclaims any other warranties and assumes no duty to provide notice if it becomes aware of any deficiencies in these estimates.) The reader accepts full responsibility for any use or application of these estimates and specifically understands and acknowledges the limited reliability of these estimates. 0 0.05 0.1 0.15 0.2 0.25 0.3 (Ti-Ta)/I (F sgfl hr/ffn ) EFFICIENCY vs. FLOW (for typ. conditions) Additional test data available on request P/N 06359G 09/06 4 WEIGHT: F' Without Water: 4 ft. X 8 ft. 13.5,lbs (5.04 kg) or 0.42 lbs/fe (2.05 kg/M) 4 ft. X 10 ft. 15.9 lbs (5.93 kg) or 0.40 Ibs/fe (1.95 kg/m ) l 4 ft. X 12 ft. 18.3 lbs (6.83 kg) or 0.38 lbs/fe (1.86 kg/m2) With Water: 4 ft. X 8 ft. 51.1 lbs (19.1 kg) or 1.60 lbs/ft2 (7.81 kg/m2) 4 ft. X 10 ft.. 59.8 lbs (22.3 kg) or 1.50 lbs/fe (7.32 kg/m2) 4 ft. X 12 ft. 68.5 lbs (25.6 kg) or 1.43 lbs/ft2 (6.98 kg/m2) ABSORPTIVITY: 0.96 F EMISSIVITY: 0.90 TIME CONSTANT: 64 seconds TESTED OUTPUT: 1,014 BTU/ft2 (Florida Solar Energy Center) PERFORMANCE CURVES: } MEASURED EFFICIENCY INCIDENT ANGLE Average flow rate 4.9 gpm (1113 Vhr) CHARACTERISTICS Average wind velocity 2.4 mph (3.9 kndhr) 1 W J ` Z K - 0.95 aw F LL W p 0.9 02 U 0.85 0.8 90 so 70 > 60 Z ,L a 50 LL 40 LL W 30 L , 20 10 0 '0 0.2 - 0.4 0.6 0.8 1 -. 0 0.05 0.1 0.15 0.2 0.25 0.3 ` +� (1/(COS INCANG))-1 (rFTa)A(F scfl WnJ) - PRESSURE vs. FLOW EFFICIENCY vs. FLOW (for typ. conditions) 8. 6 04, J j Q 2 0 o.ao 0.70 .. 0' 1 2 3 4 0 1 2 3 4 5 6 7 8 FLOW RATE (gpm) FLOW RATE (gpm per panel). All specifications and dimensions set forth above are as estimated by FAFCO Inc., but are not intended to be.precise and should not be relied upon as precise without independent verification. These estimated specifications and dimensions are subject to change without notice. Nothing contained herein is intended or should be construed to expand or extend FAFCO Inc.'s warranty, or establish any express or implied warranties of any nature, other than as contained in the Twelve Year Warranty Agreement. (FAFCO Inc. disclaims any other warranties and assumes no duty to provide notice if it becomes aware of any y deficiencies in these estimates.) The reader accepts full responsibility for any use or application of these estimates and specifically understands and acknowledges the limited reliability of these estimates. Additional test data available on request P/N 06359G j 09/06 Bin.# City. of La Quiilta Buiidiag U Safety Division P.O. Box 1504,78-495 Calle Tampico L.a.Quinta, CA 92253- (760) 777-7012 Building Permit Application and Tracking Sheet Permit # (,>�(p ` Project Address: Owner's Name:. G A. P. Number. Address: k&, UA Legal Description: Contractor. ` S City, ST, Zip:LrAQ),3f . Z zs- 3 _ r Telephone: "� N'j`(�r�fs • ' Address: 7QZwo , ProjectDescription: City, ST, Zip:fo 2 Z Telephone:76o ��&\ State Lic. # : 3 8? Z City Lic. #; Arch., Engr., Designer Address: City., ST, Zip: Telephone: State Lic. #: . w y u �' Name of Contact Person: o Construction Type:. Occupancy: Project type (circle one): New Add'n Ater Repair Demo Sq. Ft.: # Stories: #Univ: Telephone # of Contact Person: (jp — �, Estimated Value of Project APPLICANT: DO NOT N Submittal Req'd Rec'd TRACKING PERMfi' FEES Plan Sets Plan Check submitted ini?Item Amount Structural Calm Reviewed, ready for corrections L Ad Ian Chcck Deposit. . Truss Calcs. Called Contact Person an Check Balance Tithe 24 Cales. Pians pickeduP Construction Flood plain plan Plans resubmitted Methariital Grading plan 2a1 Review, ready for correctionsfissue Electrical Subcontattor List Called Contact Person Plumbing Grant Deed Plans picked up S,M.L H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '^' Review; ready for correctionsfissue Developer Impact Fee Planning Approval Called Contact Person Pub. Wks. Appr ' Date of permit Issue School Fees Total Permit Feer