14-0260 (AR)P.O. BOX 1504
78495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
14-00000260
Property Address:
47355 VIA KORON
APN:•
643-100-014-193 -26152 -
Application description:
ADDITION - RESIDENTIAL
Property Zoning:
LOW DENSITY RESIDENTIAL
Application 'valuation:
2019.2
Applicant:
.. 4
BUILDING & SAFETY DEPARTMENT
r BUILDING PERMIT
Architect or Engineer:
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 5/09/14
Owner:
MARSHAL RESIDENCE
47355 VIA KORAN
LA QUINTA, CA 92253
(250)287-6394, D d
Contractor: filfw 0928 ,�14-
UNIQUE CONSTRUCTION
83740 CITRUS AVE. , UNIT J C/%).
INDIO, CA 92201 F�N�yCE QUyyl
��w���1� (760)342-2730
VL > aE�
(.p*4 t�' Lic..No. No.: 943480
LICENSED CONTRACTOR'S DECLARATION - WORKER'S COMPENSATION DECLARATION '
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: .
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. _ 'I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided _
License CI ss: B - Li e N 943480 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is '
issued.
Ilk Date: J �� ' Contractor. ZI have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
_ .Code, for the performance of the work for which this permit is issued. My workers' compensation
OWNER -BUILDER DECLARATION - - insurance carrier and policy number are:
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier SECURITY NATL Policy Number SWC1037402
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, 1 shall not employ any
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the -- - person in any manner so as to become subject to the workers' compensation laws of California,
permit to file a signed statement thathe or she is licensed pursuant to the provisions of the Contractor's Stateand.agree that, if I should become subject to thew ' compensation provisions of Section -
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the Lab C de, I shall for p y those provisions.
that he or she is exempt therefrom and the basis for the alleged exemption.. Any violation of Section 7031.5 by (/
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: - Date—/ Applicant: �-
1 _ 1 1, as owner of the property, or my employees with wages as their' sole compensation, will do the work, and K.
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL; AND SHALL
Contractors' State License Law does not apply to an owner of property who builds or improves thereon, - SUBJECT AN. EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND -
• - and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
one year of completion, the owner -builder will have the burden of proving that he or she did not build or _
improve for the purpose of sale.). - APPLICANT ACKNOWLEDGEMENT
1 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application.
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1 . -Each person upon whose behalf this application is made, each person at whose request and for
- _ - - pursuant to the Contractors' State License -Law.). -whose benefit work is performedunderor`pursuant to -any permit issued as'a result of this application,-
(_) I am exempt under Sec. , B.&P.C. for this reason - the owner, and the applicant; each agrees to, and shall defend, indemnify and hold harmless the City '
"r of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
Date: _ Owner:- - 2. Any permit issued as a result of this application becomes null and void if work is not commenced -
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
CONSTRUCTION LENDING AGENCY - permit to cancellation. ,
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the - I certify that I have read this application and state that the above infor ion is ect. I agree to comply with all .
work for which this permit is issued (Sec. 3097, Civ. C.). - city and count ordinances and state laws relating t building constru on,-anAqfeby authorize representatives
- - of thi ® ty q enter upon the above-mentioned p pe y for ins Y n p os -
• Lender's Name: ,
xDate: Signature (Applicant or Age ). '
'Lender's Address: - /
LQPERMIT
Application Number
14-00000260
Permit . . .
ROOM ADDITION 2013
Additional desc
Permit Fee
181.61
Plan Check Fee
.00
Issue Date
Valuation
0
Expiration Date :
11/05/14
Qty Unit 'Charge
Per
Extension
1.00 120.1200_LS
MISC
ROOM ADDN,,"1ST 100 SF
120.12
1.00: 61.4900
EA, MISC
ROOM ADDN, ADDL 500 SF
61.49
Permit
ELECTRICAL 2013
Additional.desc .
Permit Fee . . . .
143.00
Plan Check Fee
.00
Issue Date.
Valuation . . .
0 ,
Expiration Date
11/05/14
Qty Unit Charge
Per
Extension
- 1.00 143.0000
----------------------------------------------------------------------------
LS ELEC
NEW RES, FIRST 1 KSF
143.00
Permit MECHANICAL 2013
Additional desc .
Permit Fee . . . .
107.25
Plan Check Fee
.00
Issue Date
Valuation . . . .
0
Expiration Date ..
11/05/14
Qty Unit Charge
Per
Extension
1.00 35.7500
EA MECH
FURNACE
35.75
1.00 23.8300
EA MECH
WALL HEATER
23.83
1.00 35.7500
EA MECH
CONDENSER/COMP
35.75
1.00 11.9200
----------------------------------------------------------------------------
EA MECH VENT FAN
11.92
Permit
PLUMBING 2013
Additional desc .
Permit Fee . . . .
- 83.44
Plan Check Fee .:
00
Issue Date
Valuation
0
Expiration,Date
11/05/14
Qty Unit Charge
Per
Extension
4.00 11.9200
EA PLBG
FIXTURE/TRAP
47.68
1.00 11.9200
fill PL -RG
WATRR KRATER.,/VE T
11 97
1.00 11.9200
EA PLBG
WATER INST/ALT/REP
11.92
1.00 11.9200
LS PLBG
GAS SYS, 1-4 OUTLETS'
11.92
--- - ------------------
Special Notes and Comments.
NEW DETACHED CASITA 353 SQ. FT. PER 2013
-
LQPERMIT
Application Number
. . . .
14-00000260
------------------------------"---------------------------------'
Special Notes and Comments
CRC CODES.THIS PERMIT DOES NOT
INCLUDE
-
POOL, SPA-, BLOCK WALLS ,DRIVEWAY
APPROACH,.FIRE-PIT
OR BBQ.
May 5, 2014 1:35:42
PM JJOHNSON.
--
-----------------_-_------------
Other Fees . .
----------------
----------------
BLDG STDS ADMIN (SB1473)
2.00
HOURLY PLAN
CHECK
210.00
PLAN CHECK,.ELECTRICAL
47.19
PLAN CHECK,
ROOM ADDITION
185.90
PLAN CHECK,
MECHANICAL
57.20
PLAN CHECK,
PLUMBING
90.58
STRONG MOTION (SMI) - RES
2.02
Fee summary
Charged
Paid
Credited
Due
Permit Fee Total
515.30
.00
.00'
515.30
Plan Check Total
.00
.00
'.00
.00
Other Fee Total
594.89
.00
.00
594.89
Grand Total
1110.19
.00
.00
1110.19
LQPERMIT
i
a'nCity
C
of La Quinta
. Building �' SafetyDivisi n
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
i�
Project Address:. 7 55 Vi�o��Ah-/
Owner's Name: S '
7
A. P. Number: A3-100- 01q q
Address: y- iss- V/;A 4-1
Legal Description:
City, ST, Zip: L4N , n #-► CA- 12 "S-7 . .
Contractor: (4m I Q U� d�rS }+e.. a �-,a
Telephone:
Address: g3-7yo C+, j,Lw f qL< U�� a
Project Description:
City, ST, Zip: Vrld; u C A 9 -jz o I
3 S 3 S 1�7.
Telephone: 7t, d - 3 4 2 - Z? 3 0
'Jji:i3ii•il :: •iii'C:yy;; :•i •.i?!S•ii:Y: i:•i
State Lic. # : q -j 3 WO
City Lic.
Arch., Engr., Designer: M A A -K (9
Address: —77—(,70 gN6 7 A
City., ST, Zip: QA I M 0;C_T X.L-T 646-
46-
Tele hone:
Telephone:
P. 74e — Zvo -.S'oq
:<•<.:»:::»::»>: ::>;>:
:.>>::::,:i:>;:E::>•::::>>.::>;::::::;:::>;:,:;;::>::;::
Construction Type: Occupancy:
State Lic. #:
Project acirc ne • New Add'n Alter Repair Dem 0
Name of Contact Person:„�.T 1�p �r, J
Sq. Ft.:
#Stories:
# Units:
Telephone #,of Contact Person: ZLo - 5 7 8'-
Estimated Value of Project: 34) o aGi
APPLICANT: DO NOT WRITE BELOW THIS LINE
N
Submittal
Req'd
Rec'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item Amount
Structural Calcs.
Z
Reviewed, ready for. corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person
3611CPlan
Check Balance.
Title 24 Calcs.
'Plans picked up
Construction.
Flood plain plan
Plans resubmitted
(
Mechanical
Grading plan
2°" Review, ready fo corrections ssue
4 ZQ11
Electrical
Subcontactor List•
Called Contact Person
,-)q jjq
Plumbing .
. Grant Deed
H.O.A. Approval
Plans picked up
Plans resubmitted
S.M.I. •
Grading
IN HOUSE:-
'"' Review, ready for correcti s/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
Sc11061 Fees
Total Permit F_es
1
n
r
CERTIFICATE OF COMPLIANCE.
�LVIFZ
scy
Desert Sands Unified,School District
47950 Dune Palms Road ¢ BERMUDA DUNES r.
Date 5/9/14Laf rn RANCHO
A, '
ALM DESE
No. 32086 `G PLA QUINTA y
(760) 771-8515 oo y7
Owner Marshall APN # 643-100-014-193
Address-: 47-355 Via Kironr Jurisdiction . La Quinta
City. La Quinta . ..Zip .92253 Permit #
Tract # No. of Units 1
.Type DetachedGuest House.
Lot # No. Street S.F. Lot #' No. Street S.F.
Unit 1 47355.' . Via Kiron 353 ... Unit.6
Unit 2 Unit 7
Unit 3 : Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways; residentialadditions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking,, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility.fees imposed pursuant to
Education Code.Section 17620 and Government Code 65995 Et Seq.
in the amount of $3.20 X 353 S.F. or $1,129.60 have been paid for the property listed above and that
building permits -and/or Certificates of Occupancy for this square footage in this proposed project'may now be issued.
Fees Paid By Bank of America/KurtHardin Check No. 002272422•
Bank Name/Recipient of CertificateTelephone
Funding Residential
By Dr.'Gary Rutherford
Superintendent •. ,
Fee collected /exempted by Espe ara' Payment Recd - C$0.00 717. 71
$1,129.60 �over/uhde
^; h ^
Signature..
NOTICE: Pursuant to Government' Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will,begin to run from the date on which the building or installation permit for this project is issued, or.from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, .whichever is earlier
NOTICE: This Document NOT VALID without embossed seal.
Embossed Original 7 Building Department Applicant Copy -,Applicant/Receipt. Copy -Accounting ;
_"
'Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/3/2014
Electronically Signed at CalCERTS.com by Mark B Valentino (Mark B Valentino, Architect) 2/6/3014
CO
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Marshall Guest House
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Additior,/Alteration
Date
2/3/2014
Project Address
47-355 Via Kiron La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
345
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavityf Features see Part 2 of 5 Status
Roof Wood Framed Attic R-38 345 Radiant Barrier New
Wall Wood Framed R-21 585 New
Slab Unheated Slab -on -Grade None 345 Perim = 76' New
FENESTRATION U- Exterior
Orientation Area(ff`) Factor SHGC OverhangSidefins Shades Status
Rear (N) 34.6 0.330 0.30 none none Bug Screen New
Rear (N) 64.0 0.330 9.29...,,none.., ,,„none r_W Bug -Screen ,K _ New
HVAC SYSTEMS
Qty. HeatingMin. Eff CoolingMin. Eff Thermostat Status
1 Split Heat Pump 10.00 HSPF Split Heat Pump 15.5 SEER Setback
New
HVAC DISTRIBUTION Duct
Location HeatingCoolingDuct Location R, -Value Status
HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 6�0
New
•e g e A C UINTA
ATER. HEG x _ W j ut'11
Qty. Type Gallons Min. Eff D,is trivtj Torr PETY pp Status
1 sta E1ec 0 1.00 Atll Pipes Ins_
ew
LONSTRUC v
C b
4MUNITY pFvFi nI2Wr=AI:pa
EnergyPro5.1byEne So ser Number: 6712 Run Code: 201402-03T10:53:11 ""—ID:
Pae 1 of 5
Reg: 214-N0008358A-000000000-0000 Registration Date/Time: 2014/02/03 19:48:40 HER rovader: CalCERTS, Inc
'Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 2/3/2014
Electronically Signed at CalCERTS.com by Mark B Valentino (Mark B Valentino, Architect) 2/6/2014
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Marshall Guest House
Building Type m Single Family O Addition Alone
❑ Multi Family O Existing+ Addition/Alteration
Date
213/2014
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The e-Iforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies teased on the adequacy of
the special justification and documentation submitted.
HIGH MASS Design - Verify Thermal Mass: 211.0 ft2 Covered Slab Floor, 3.500" thick at Guest House
HIGH MASS Design - Verify Thermal Mass: 134.0 ft2 Exposed Slab Floor, 3.500" thick at Guest House
The Roof R-38 Roof (R.38.2x14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and instahation criteria as specified in
Residential Appendix RA4.2.2.
J am
P f t' T77,\,. �1h t
((r
k�
f .. . ill' ... + Y -•
HERS REQUIRED,, VERIFICATION
4�+Ar .. V y, • ! �' �:'. y, .. �ti �,-- .1+�.E-�b/
Items in'k Section require field testing and/or veeification'by a certified HERS Rater. "The Inspector -must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 1 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC
System.
The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
CITY 0. LA 0111INTA
BUILDING & SAFETY DEPT.
' ✓�"LU
FOR CONSTfaf -(-T1r-Nr,,
BY
L
EnerqvPro 5.1 by EnerqySoft User Number.' 6712 Run Code: 201402-03T10:53:11 ID: Page 2 of 5
Reg: 214-N0008358A-000000000-0000 Registration Date/Time: 2014/02/03 19:48:40 HERS Provider: CalCERTS, Inc
Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 2/3/2014
Electronically Signed at Ca10ERTS.com by Mark B Valentino (Mark B Valentino, Architect) 2/6/2014
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Marshall Guest House
❑ Multi Family ❑ Existing+ Addition/Alteration
2/3/2014
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kgtu/ft2- r
Space Heating 5.94 5.53 0.41
Space Cooling 95.98 82.39 13.59
Fans 2072 23.94 -3.22
Domestic Hot Water 6172 68.40 -5.68
Pumps 0.00 0.00 0.00
Totals 184.35 180.26 4.10
Percent Better Than Standard: 2.2%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (S) 0 0
Fuel Available at Site: Natural Gas (M 0 0
Raised Floor Area: 0 (N) 684 99
Slab on Grade Area: 345 (E) 0 0
Average Ceiling Height: 9.0 Roof 345 0
Fenestration Average U -Factor: 0.33 TOTAL: 99
Average SHGC: 0.29 Fenestration/CFA Ratio: 28.6%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance`lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Scott Design and Title 24, Inc,
Address 77-085 Michigan Drive Name Tim Scott 2/3/2014
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phcne (760) 200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms -and -worksheets, with fie specifications, and .
with any other calculations submitted with this permit application, and 6recognizes,that compliance using'duet-design,
A
duct-sealing,verification of refrigerant charge, insulation installation ualii " andYbuil en elc 1e.1in re uire
9d
uq
installer testing and certificationandfield verification by an approved HER-S)r'ater NG & SAFETy DEF- a
q s
Designer or Owner (per Business &Professions Code) ��_ �®
r
Company Mark B. Valentino, Architect
Address 77-670 Springfield Lane, Suite 7A Nane Mark B. Valentino
City/State/Zip Palm Desert, CA 92211 Phcne (760) 200-5099 DATE __ B�,
Signed— -License # Date
EnemyPro 5.1 by Enemysoft User Number 6712 RunCode: 2014 02-03 71 0:53:11 ID: Page 3 of 5
Reg: 214-N000835BA-000000000-0000 Registration Date/Time: 2014/02/03 19:48:40 HERS Pro,,ider: CalCERTS, Inc
E°'lectronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/3/2014
Electronically Signed at CalCERTS.com by Mark B Valentino (Mark B Valentino, Architect) 2/6/2014
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Marshall Guest House
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
2/3/2014
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof 345 0.025 R-38
0 0 New 4.2.1-A21 Guest House
Wall 196 0.069 R-21
0 90 New 4.3.1-A6 Guest House
Wall 71 0.069 R-21
0 90 New 4.3.1-A6 Guest House
Wall 183 0.069 R-21
0 90 New 4.3.1-A6 Guest House
Wall 135 0.069 R-21
0 90 New 4.3.1-A6 Guest House
Slab 211 0.730 None
0 180 New 4.4.7-A1 Guest House
Slab 134 0.730 None
0 180 New 4.4.7-A1 Guest House
FENESTRATION SURFACE DETAILS
ID Type Area Ll -Factor' SHGC2
Azm Status Glazing Type Location/Comments
1 Window 5.3 0.330 NFRC 0.30 NFRC 0 New Milgard Fixed Guest House
2 Window 5.3 0.330 NFRC 0.30 NFRC 0 New Milgard Fixed Guest House
3 Window 64.0 0.330 NFRC 0.29 NFRC 0 New Milgard Door Guest House
4 Window 24.0 0.330 NFRC 0.30 NFRC 0 New Milgard Fixed Guest House
'4P ( ,i 1 ! 1 1
,t ''
ti rte.
L, _ . _ .� r
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-8 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window
ID Exterior Shade Type SHGC H t Wd
Ove hang Left Fin Right Fin
Len H t LExt REA Dist Len I H t Dist Len H t
1 Bug Screen 0.76
2 Bug Screen 0.76
3 Bug Screen 0.76
4 Bug Screen 0.76
I f TV r) tZ I A --
I UIv :5w1-L1Y D11 - PT
I rRw I.`�I�K�n rf�_a-o
dti _d Y4#V--ILS'
I HUCMMi
"1 Ez ABY
EnergyPro 5.1 by EnergySoft User Number: 6712
Run Code: 201402-03710:53:11 ID: Page 4 of 5
Reg: 214-N0008358A-000000000-0000 Registration Date/Time: 2014/02/03 19:48:40 HERS Provider: CalCERTS, Inc
'Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/3/2014
Electronically Signed at CalCERTS.com by Mark B Valentino (Mark B Valentino, Architect) 2/6/2014
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R
Project Name
Marshall Guest House
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
2/3/2014
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existinq Altered Removed Volume Year Built
HVAC 1 Guest House
345 3,105
Totals 345 0 01 01 1
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC 1 1 Split Heat Pump
10.00 HSPF Split Heat Pump 15.5 SEER Setback New
I �� 1
J � I J_• 1 1
t rf
HVAC DISTRIBUTION
`- ` . t -
System Name Heating
I , _ -`Duct Ducts
Cooling Duct Location Tested? Status
-R-Value
HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 6.0 m New
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Bosch RP7P
1
Instant Elec
All Pipes Ins
24,574
0
1.00
n/a
n/a
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
Q —
TY O
F'ILDING&
S stem Name�,--„r-,Len.gth,f=Diameter
LA QUINT
SPipe�ly
AI
Bif—YPT.
Insul.
Thick.
Qt . HP
Plenum Outside Buried
❑
r v r- r� r�
V ip
LJ
I
❑
FOR UU
51 HUCTION
❑
I
❑
N C
EnergyPro 5.1 by Ene Soft User Number: 6712
RunCode: 201402-03710:53:11 ID: Page 5 of 5
Reg: 214-N0008358A-000000000-0000 Registration Date/Time: 2014/02/03 19:48:40 HERS Provider: CalCERTS, Inc
BUILDING ENERGY ANALYSIS REPORT
PROJECT:,
Marshall Guest House
47-355 Via Kiron
La Quinta, CA 92253
Project Designer:
Mark B. Valentino, Architect
77-670, Springfield Lane, Suite 7A
Palm_ Desert, CA 92211
(760) 200-5099
Report Prepared by:
• Tim Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Palm Desert, Ca 92211
(760) 200-4780 C17� ��
SUfLOl� LA C��JINTA .
G & SAFETy O
A Pp EP7
FOR �O ®QED
STR CT��N
' DATE BY
Job Number: REL;
El
MAR 0 7 2014
Date:
CITY OF LA QUINTA
2/3/2014 COMMUNITY DEVELOPMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
f This program developed by EnergySoft, LLC — www.energysoft.com.
S"L„a EnergyPro 5.1 by Energ Soft User Number. 6712 RunCode: 2014-02-03710:53:11 /D:
4
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Marshall Guest House
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition!Alteration
Date
2/3/2014
Project Address
47-355 Via Kiron La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
345
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity f Features see Part 2 of 5
Status
Roof Wood Framed Attic R-38 345 Radiant Barrier
New
Wall Wood Framed R-21 585
New
Slab Unheated Slab -on -Grade None 345 Perim = 76'
New
FENESTRATION U- Exterior
Orientation Area(fo Factor SHGC Overhang Sidefins Shades
Status
Rear (N) 34.6 0.330 0.30 none none Bug Screen
New
Rear (N) 64.0 0.330 0.29 none none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat
Status
1 Split Heat Pump 10.00 HSPF Split Heat Pump 15.5 SEER Setback
New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value
Status
HVAC 1 Ducted Ducted Attic, Ceiling Inswented—_,_ 6.0
New
Cy
'1UiLD1h1(-' Q L--" QUIN-r�1
tl
WATER HEATING APP � ��� DEPT
Ot . Type Gallons Min. Eff Distifloution,p �,,, �1/Pr) Status
1 Instant E/ec 0 1.00 AI! Pipes Ins v� v J t UCTI
1 New
'
BATE—
BY_
EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 201402-03710:53:11 ID:
Pa e3 of14
CJ
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Marshall Guest House
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
1 2/3/2014
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HIGH MASS Design - Verify Thermal Mass: 211.0 ft' Covered Slab Floor, 3.500" thick at Guest House
HIGH MASS Design - Verify Thermal Mass: 134.0 ft' Exposed Slab Floor, 3.500" thick at Guest House
The Roof R-38 Roof (R. 38.2x 14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in
Residential Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display.
The HVAC System HVAC 1 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC
System.
The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
EnerqyPro 5.1 by EnemySoft User Number: 6712 Run Code: 2014-02-03710:53:11 ID: Page 4 of 14
r:
0
�7'
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Marshall Guest House
❑ Multi Family ❑ Existing+ Addition/Alteration
1 2/3/2014
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 5.94 5.53 0.41
Space Cooling 95.98 82.39 13.59
Fans 20.72 23.94 -3.22
Domestic Hot Water 61.72 68.40 -6.68
Pumps 0.00 0.00 0.00
Totals 184.35 180.26 4.10
Percent Better Than Standard: 2.2%
BUILDING COMPLIES - HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (S) 0 0
Fuel Available at Site: Natural Gas (w) 0 0
Raised Floor Area: 0 (N) 684 99
Slab on Grade Area: 345 (E) 0 0
Average Ceiling Height: 9.0 Roof 345 0
Fenestration Average U -Factor: 0.33 TOTAL: 99
Average SHGC: 0.29 Fenestration/CFA Ratio: 28.6
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Scoff Design and Title 24, Inc,
2/3!2014
Address 77-085 Michigan Drive Name Tim Scott
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms andpworksheetswith the specifications, and
with any other calculations submitted with this permit application, and recognizes that�Y o mpliancce A s^ng_ uct design,
duct sealing, verification of refrigerant charge, insulation installation qualityf apd-building envelop �ti Ing -require
�� ' '
installer testing and certification and field verification by an approved HERS rater. �'c SAFE•f-�, D
Designer or Owner (per Business & Professions Code) j1pe. r
Company Mark B. Valentino, Architect STRUCTIpIV
�S
-
Address 77-670 Springfield Lane, Suite 7A Name Mark B. Valentino DATE `O60gQ 3
City/State/Zip Palm Desert, CA 92211 Phone (760) 200-5099Signed- BY License # Date
EnemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 201402-03710:53:11 /D: Page 5 of 14
•
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Marshall Guest House
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
213/2014
OPAQUE SURFACE DETAILS
Surface U Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof 345 0.025 R-38
0 0 New 4.2.1-A21 Guest House
Wall 196 0.069 R-21
0 90 New 4.3.1-A6 Guest House
Wall 71 0.069 R-21
0 90 New 4.3.1-A6 Guest House
Wall 183 0.069 R-21
0 90 New 4.3.1-A6 Guest House
Wall 135 0.069 R-21
0 90 New 4.3.1-A6 Guest House
Slab 211 0.730 None
0 180 New 4.4.7-A1 Guest House
Slab 134 0.730 None
0 180 New 4.4.7-A1 Guest House
FENESTRATION SURFACE DETAILS
ID Type Area U -Factor SHGC2
Azm Status Glazing Type Location/Comments
1 Window 5.3 0.330 1 NFRC 0.30 NFRC 0 New Milgard Fixed Guest House
2 Window 5.3 0.330 NFRC 0.30 NFRC 0 New Milgard Fixed Guest House
3 Window 64.0 0.330 NFRC 0.29 NFRC 0 New Milgard Door Guest House
4 Window 24.0 0.330 NFRC 0.30 NFRC 0 New Milgard Fixed Guest House
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window
ID Exterior Shade Type SHGC Hat Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len Hat Dist Len H t
1 Bug Screen 0.76
2 Bug Screen 0.76
3 Bug Screen 0.76
4 Bug Screen 0.76
I " 1 5 R [1 _ �-J
I A -c r -
r Y- r-• r
° r t,
DATE _ B
Ene Pro 5.1 6 Ener Soft User Number: 6712
RunCode: 201402-03710:53:11 IB' Pa e 6 of 14
•
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5) CF -1 R
Project Name
Marshall Guest House
Building Type 10 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
213/2014
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existing Altered Removed Volume Year Built
HVAC 1 Guest House
345 3,105
Totals 1 345 01 01 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Type Min. Eff. Thermostat Type Status
HVAC 1 1 Split Heat Pump
—Cooling
10.00 HSPF Split Heat Pump 15.5 SEER Setback New
HVAC DISTRIBUTION
System Name Heating
Duct Ducts
Cooling Duct Location R -Value Tested? Status
HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 6.0 m New
WATER HEATING SYSTEMS
S stem Name
Ot .
Type
Distribution
RatedTank
Input
Btuh
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Bosch RP7P
1
Instant Elec
All Pipes Ins
24,574
0
1.00
n/a
n/a
New
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING
SYSTEM
PIPING
Control
Hot Water Piping Length
(ft)
c
0
ro
a —
"stem-Nam�F L.
—Ripe
4e.It' th .
Pipe
, D'iamet.e
Insul.
Thick.
Ot .
HP
Plenum Outside Buried
y
❑
f FOR fol r °
I. 1 /f r
.
❑
EnergyPro 5.1 by Ene Soft User Number: 6712
Run Code: 201402-03T10:53:11�-ID_ — Pae 7 of 14
4
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Date
arshall Guest House
2/3/2014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all 'oints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
e ui ped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15�psi;ameets the requirements of Standards Table
123-A. 1 ,-, #_,_„ _
150(6)3A: Insulation is protected from damage, including that due to sunlight, moisture ` ui mentmlinte.narf d ind-----
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor'retardant?or. is&e6 ioWd^entir'ely i tl /t
conditioned space.
150(')4: Solar water-heatingsystems and/or collectors are certified b the Solar Ratingand C rtifica itit o Cor oration f
. v' l LUNSr�UCT I N
t
n„T�
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201402-03T10:53:11 Page 8 of 14
4
4
4
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
arshall Guest House
2/3/2014
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or.automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines or built-up connections for future solar heating.
1 .
14 b 2: Outdoor pools or as that have a heat um or as heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Liqhting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable -control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms,are high efficacy-and=coed by antroll
roll
manual -on occupant sensor. I k'I I! y o,
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no niore thar6 A, alts f r perr"'ling r foot .of
�o�
illuminated cabinet. R E� Fp-t-
�D
FO CONSTRUCTION
DATE
EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014 -02 -03T10:53:1'1 ---ID:, (page 9 of 14
4
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
arshall Guest House
1 2/3/2014
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130 131, 134, and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 4119.
OF LA
3U C�lll
BUILDING rVT
A
& SAFE �'
OEP7 ;
FO
NSTRUCTION
FATE
EnergyPro 5.1 by EnergySoft User Number.' 6712 RunCode: 201402-03T10:53:1 Page 10 of 14
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
arshall Guest House
System Name
HVAC 1
Date
2/3/2014
Floor Area
345
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 270
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 16
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System
18,000
6,345
1,131 295
6,871
Total Output Btuh
18,000
0
Output Btuh/s ft
52.2
433
305
Cooling System
0
0
Output per System
14,000
613
377 16
717
Total Output Btuh
14,000
0
1,507
0
Total Output Tons
1.2
433
305
Total Output Btuh/s ft
40.6
Total Output s ft/Ton
295.7
1 7,823
8,198
Air System
CFM per System
425
HVAC EQUIPMENT SELECTION
Airflow cfm
425
Mitsubishi #SEZ-KD15NA 11,448 226
11,242
Airflow cfm/s ft
1.23
Airflow cfm/Ton
364.3
Outside Air %
3.7%
Total Adjusted System Output 11,448 226
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
11,242
Outside Air cfm/s ft
0.05
Jan 1 AM
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
Ak-
16 cfm
69 OF
68 OF 93 OF �-� 93 OF
f Cil �
Heating Coil Supply Fadi °
425 cfm 92 F
ROOM
70 OF
I
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
16 cfm
75 / 60 OF
76/61 OF 51 /50°F 51 /50°F CITY OF LA Q rIN I A
_ G)U L I N Q. g ,w= E� � T.
c
SupplyFan AAPPROVED °
Cooling Coil 4225 cfm FOR CONSTR.U.CTI.01_ / 5o F
43.8% ROOM
DATE
1..s 74 I -60-°F
EnergyPro 5.1 by EnergySoft
User Number: 6712 RunCode: 201402-03710:53:11 /D: Page 11 of 14
•
•
•
ROOM LOAD SUMMARY
Project Name Date
Marshall Guest House 2/3/2014
System Name Floor Area
HVAC 1 345
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING'EAK COIL HTG. PEAK
Zone Name =Room Name I Mult. I CFM I Sensible I Latent CFM I Sensible Latent CFM I Sensible
Guest House I Guest House I 1 1 2701 6,3451 1,131 2701 6,3451 1,131 2951 6,871
PAGE TOTAL
TOTAL
270
6,345
1,131
295 6,871
270
6,345
1,131
295 6,871
Total includes ventilation load for zonal systems.
EnemyPro 5.1 by Ener Soft User Number: 6712 RunCode: 201402-03710:53:11 /D: Pae 12 of 14
•
•
ROOM HEATING PEAK LOADS
Project NameDate
Marshall Guest House
2/3/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Guest House
Floor Area 345.0 ftz
Indoor Dry Bulb Temperature 70 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT *F
=
=
=
=
c
=
=
_
=
=
=
=
=
-
=
=
=
=
=
=
=
_
=
=
=
=
=
=
T—gq
d
44
Btu/hr
R-38 Roof (R.38.2x14.16)
345.0
0.0250
44
380
R-21 Wall (W.21.2x6.16)
585.4
0.0690
44
1,777
Milgard Fixed
34.6
0.3300
44
502
Milgard Door
64.0
0.3300
44
929
Slab -On -Grade
perim = 76.0
0.7300
44
2,441
/
L
;1 E
X
X�,
i
FOR
v H N A
�.I k i„%"�
n���., „ ..
rutrl.
R �.� —... .
A PageRTptal
CONS I RUCTION
/60] X
BYpT
RnA�iT
I I tl I
I ��
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 345 X
Area
another room
9.00 X 0.347
Height vAOM:
U 6030
= 841
TOTAL HOURLY HEAT LOSS FOR ROOM 6,871
EnergyPro 5.1 by Energ Soft User Number: 6712 RunCode: 2014-02-03T10:53:11 /D: Page 13 of 14
•
C
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Marshall Guest House
2/3/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Guest House
Outdoor Dry Bulb Temperature
112 OF
Floor Area 345.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 74 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof (R.38.2x14.16) (N) 345.0 X 0.0250
X 56.0 =
483
R-21 Wall (W.21.2x6.16) (N) 585.4 X 0.0690
X 23.0 =
929
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
X
X =
Page Total
1,412
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area GLF
Btu/hr
Window (N) 0.0 X 17.7 +
5.3 X 17.7 =
94
Window (N) 0.0 X 17.7 +
5.3 X 17.7 =
94
Window (N) 0.0 X 17.4 +
64.0 X 17.4 =
1,111
Window (N) 0.0 X 17.7 +
24.0 X 17.7 =
426
X +
X -
X +
X -
x
x -
x
x -
x
x -
Page Total
1,725
Internal Gain
Btu/hr-
tu/hrOccu
Occupants
ants 4.0 Occupants X 230
Btuh/occ. =
920
Equipment 1.0 Dwelling Unit X 1,600
Btu =
1,600
Infiltration: 1.064 x 0.90 x 18.88 x 38 =
688
Air Sensible CFM ELA AT
i✓�
�F 0 A no iik1A-1'
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM p
6 ISI fl
. - " ° v " r %
Ini� c� n rr �. s,345
-
_ �J-,J L:uCf,
'
Latent Gain APPROVED
Btu/hr
Occupants 4.0 Occupants x F20o136 QNS.TRUCTIO-N 1
800
Infiltration: 4,771 x 0.90 x 18.88 X0.00407 --ATE-__
331
Air Sensible CFM ELA AW
BY
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,131
-EnergyPro 5.1 by EnerqvSoft User Number: 6712 RunCode: 2 014-02-03 710:53:11 /D:
Pae 14 of 14