13-0738 (RER)r
0
P.O. BOX 1504. �f4 40.(/VOICE (760) 777-7012,
78-495 CALLS TAMPICO / FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT v INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date:, 9/03/13
Application Number:
13-00000738 Owner: ® d
Property Address: 48557 VISTA PALOMINO LARRY DICKEN80N
APN: 649-540-008- - 48857 VISTA PALOMINO
Application description: REMODEL - RESIDENTIAL LA QUINTA, CA 92253 S,3
EP o3 2o
Property Zoning: LOW; DENSITY RESIDENTIAL ( U J
Application valuation: 50000 (;J
F1NgN QuiiAJA
Contractor: PT,
Applicant: -Architect or Engineer. SANTUCCI BUILDERS INC
72529 BEAVERTAIL STREET
PALM DESERT, CA 92260
�\ (760)578-7757
\\\ Llc- No.: 820801
_ LICENSED CONTRACTOR'S DECLARATION _ - WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: -
Section 7000) of Division 3 of the Busiand Professionals Code, and my License is in full force and effect. I have and will maintain a certificate of consent to self-insure for workers' compensation, as provided
License Class: Ts
B cense No.: 820801 - _ for by Section 3700 of the Labor Code, for the performance of the.work for which this permit is
G� �' issued. -
Date: /�/� Contractor'' .1f1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
- L Code, for the performance of the work for which this permit is issued. Myworkers' compensation
OWNER-BUILDER DECLARATION - insurance carrier and policy number are:.
1 hereby affirm under penalty of perjury that) am exempt from the Contractor's State License Law for the Carrier GRANITE STATE Policy Number 51759994-12
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to - _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California,
"permit to file a signed statement that he or she is licensed pursuant to,the provisions of the Contractor's State and agree that, if I should become subject to a workers' compensation provisions of Section
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or ..1 J 00 of the Labor Co e, I shall forthwith m ly with those provisions. -
• that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by i
- any applicant for a permit subjects the applicant to a civil "penalty of not more than five hundred dollars IS5001.: 6 to e 1 Applicant. VA^kv-
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and "
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The - WARNING: -FAILURE TO SECURE W ERS' COM ENSATION COVERAGE IS UNLAWFUL, AND SHALL .
Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($.100,000)- IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. `
one year of completion, the owner-builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.). - APPLICANT ACKNOWLEDGEMENT
1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. - IMPORTANT Application is hereby made to the Director of Building and Safety fora permit subject to the
7044, Business and Professions Code: The Contractors' State License Law'does not apply town owner of conditions and restrictions set forth on this application. -
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1 . Each person upon whose behalf this application is made, each person at whose request and for
pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application,
1 _ 1 I am exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
Date: Owner: - 2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
CONSTRUCTION LENDING AGENCY permit to cancellation. _
I hereby affirm under penalty of perjury that.there is a construction lending agency for the performance of the - I certify that I have read this application and state that the above information is correct. I agree to comply with all
work for which this permit is issued (Sec. 3097, Civ. C.). city and co my ordinances and state laws relating to b Cing construction, and er, by authorize representatives
of this c ty t e ter upon the above-mentioned grope for inspection purpo es
Lender's Name:. /,-
Date:
/A �•/�^•
D� e I Signature (Applicant or Agent): ! 222
Lender's Address: !! .
— LQPERMIT
Application Number
13-00000738
Permit
. . . BUILDING 2013
Additional
desc .
Permit Fee `452.11
Plan Check Fee
.00
Issue Date
.. . .
Valuation . .
. . 50000
Expiration
Date
3/02/14
Qty Unit Charge
Per
Extension
BASE
FEE
: 431.86
` 25.00
.8100
THOU BLDG
$25,001-$200,000
20.25
Permit
. . .
ELECTRICAL 2013
Additional
desc .
Permit Fee
. . . .
47'.66
Plan Check Fee
_.00
Issue Date
'..
Valuation
0
Expiration
Date
3/02/14 '.
Qty Unit Charge.
Per
Extension
1.00
23.8300
LS ELEC
FIXTURES, FIRST 20
23.83
.1.00
23.8300
EA". ELEC
SERVICES
23.83
1 Permit
MECHANICAL 2013_
Additional
desc .
Permit Fee
83.42
Plan Check Fee
.00
Issue Date
. ."
Valuation . .
. . 0
Expiration
Date
3/02/14
Qty Unit Charge
Per
Extension
1.00
35.7500
EA - MECH
FURNACE
35'.75-
1.00
35.7500
EA MECH
CONDENSER/COMP
35.75
1.00
11.9200
EA MECH
VENT FAN
11:92
Permit
PLUMBING 2013
Additional
desc..
Permit Fee
. .
95.36.
Plan Check Fee
.00
Issue Date
Valuation
0
.Expiration
Date
3/02/14
Qty Unit Charge
Per
Extension
4.00
11.9200
EA PLBG
FIXTURE/TRAP
47.68
1.00
11.9200
EA PLBG
WATER HEATER/VENT
11.92
1.00
11.9200
EA PLBG
WATER INST/ALT/REP
11.92.
• 2.00
11.9200
LS- PLBG.GAS
SYS, 1-4 OUTLETS
23.84
--------------------------------------------------------------------
Special Notes
and Comments
353 SQ. FT.
CASITA ADDITION WITH
22 SQ. _
Application Number
13-00000738
---------------------------------------------------------------
Special Notes and Comments
FT MECH ROOM. THIS PERMIT DOES
NOT
INCLUDE POOL SPA OR BLOCK WALLS.ALL PER
2010 CALIF BUILDING CODES.
August 28, 2013 9:47.39 AM jjohnson.
- --------------------------------------------------
Other Fees . . . . . . .
BLDG STDS ADMIN (SB1473)
2.00
HOURLY PLAN
CHECK
294.00
PLAN CHECK,
ELECTRICAL."
35.-75
PLAN CHECK;
ROOM ADDITION
185.90
PLAN CHECK,:.MECHANICAL
52.43
PLAN CHECK,
PLUMBING
90.58
STRONG MOTION (SMI) - RES
5.00 -
Fee summary Charged
Paid.
Credited
Due -
--------
Permit Fee Total 678.55
----------
.00
---------- ----------
.00
678.55
Plan Check Total 00
.00,
.00
.00
Other Fee Total 665.66
.00
.00
665.66
-
Grand Total 1344.21
00
.00
1344.21,:
LQPERMIT
-
.
Din #,
City Of La QL'linta
Building & Safety Division
-1 P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address: .-2 r "S Lt 4— ems+ !tz p
Owner's Name:
A. P. Number: ton 2100 do
Address: (MLOWN0
Legal Description:
Contractor: Lt k761- t—iil Wit.; ��++G.;".;::>::::.:'.:;,,,,..
#-h c.
City, ST, Zip: .4641 KI
Telephone:
Address: 7 Z ��- "f � q ✓ ie i ;
Project Description:
City, ST, Zip: C! f M Pe5� ✓� Z v
'A'
C IdM
L.
Telephone: Z U 57 V 7 7 Y %
>"'?:''.€? ^° ?>; .'.:M
EMNOM
State Lic. # City Lic. #; L ca
Arch., Engr., Dir: (Drc
JUN 13 M3
CITY OE LA QUI1 41
Address: 4511T
P
City., ST, Zip: PIRLM
Telephone:, ��Z� Z4 <: nt?;{"<€,:J`j:>'::?a
State Lic. #: .,•,.„i ., •G�`s<=`;?
Construction Type: Occupancy:
Project type (circle one): New Alter Repair Demo
Name of Contact Person:Sq.
Ft.: 35
#Stories:
Units:
#
Telephone # of Contact Person: ff.(►
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING PERMIT FEES
b
Plan Sets
Plan Check submitted Item
Amount
Structural Calcs.
Reviewed, ready f correction Plan Check Deposit
Truss Calcs.
Called Contact Person Plan Check Balance
Title 24 Calcs.
Plans picked up Construction
Flood plain plan
Plans resubmitted Mechanical
Grading plan
2°” Review, ready for correctio /issue ' Electrical
Subcontactor List
Called Contact Person l Plumbing
•
Grant Deed
Plans picked up S.M.I.
H.O.A. Approval
Plans resubmitted Grading
IN HOUSE:-
''d Review, ready for corrections/issue Developer Impact Fee
Planning Approval
Called Contact Person A,LP,P,
Pub. Wks. Appr
Date of permit issue
School Fees
N s W D E tSS G -D
Total Permit Fees
CZs113 Nic RFC
0Ar 16-(TC)R-
o 6cK-o6( t -C '-5
. c0t.MZUTC5 1z:s up -Pyr
N
A
MENT
CERTIFICATE OF COMPLIANCE �FIEDSWF,0
Desert Sands Unified School District
47950 Dune Palms Road ¢ BERMUDA DUNES r'
rn RANCHO MIRAGE b
Date 9/3/13 La Quinta, CA 92253 INDIAN WELLS ti
No. 31799 (760) 771-8515 `fes
PALMQUINTAT
�PlNolo yeti
Owner Larry Dickinson APN # 600-200-008
Address 48557 Vista Palomino Jurisdiction La Quinta
City La Quinta Zip Permit #
Tract # No. of Units 1
Type Residential Addition
Lot # No. Street S.F. Lot # No. Street S.F.
Unit 1 48557 Vista Palomino 353 Unit 6
Unit 2 - Unit 7
Unit 3 . Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments Addition to Existing Casita
At the present time, the Desert Sands Unified School District does not collect fees.on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or.Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 353 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Jerry Santucci Check No.
Bank Name/Recipient of Certificate Telephone 760-578-7757
Funding Exempt
By Dr. Gary Rutherford,'
Superintendent
4
Fee collected lexem ed by Sh O C I Vrey Payment Recd i$0.00
. =.Over/Under _
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this II serve to notify you that the 90 -day approval period in which you may protest the fees
.or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal a
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
BUILDING ENERGY ANALYSIS REPORT
lob-- 1( (:00 two
PROJECT:
DICKENSON'S CASITA
48557 VISTA PALOMINO
LA QU I NTA, CA 92253
Project Designer:
JORGE GARCIA DESIGN AND PLANNING
45175 PANORAMA DR SUITE A
PALM DESERT, CA 92260
(760) 272-9222
Report Prepared by:
ARMANDO CHAVEZ-
TITLE 24 OF THE DE
D EQUY OF LA QUINTA
44890 SEELEY BUILDING & SAF DEPT..
LA QUINTA, CA 92 53 FAOPPf�O p
760 278.1840 R CONSTR TION
DATE /Z/
MTZ
TIRE 24 OF THE DESERT
Job Number:
2013 -JG -003 �®
C
4OG 09 20/
Date: �o I7y of 3
r M/y�NI� � 4rJIN
7/11/13` oF�F�oP�
` FNr
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 5.1 by EnergySoft User Number.- 20648 RunCode: 2013-07-11718:47:46 ID: 2013,IG-003
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF-1 R
Project Name
DICKENSON'S CASITA
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
7/11/13
Project Address
48557 VISTA PALOMINO LA QUINTA
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
353
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
IZI Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
Roof Wood Framed Attic
R-38 353 Radiant Barrier New
Slab Unheated Slab-on-Grade
None 353 Perim = 0' New
Wall Wood Framed
R-21 753 New
Door Opaque Door
None 24 New
FENESTRATION U-
Orientation Area Factor
Exterior
SHGC Overhang Sidefins Shades Status
Front (NE) 31.0 0.400
0.35 none none Bug Screen New
Left (SE) 16.8 0.400
0.35 none none Roll-down Blind or Slats New
Rear (SIM 27.5 0.400
0.35 none none Roll-down Blind or Slats New
Rear (SIM 2.0 0.650
0.48 none none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Fumace 80% AFUE Split Air Conditioner 13.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
HAVC Ducted
Ducted Attic, Roof Ins 8.0
New
WATER HEATING l r T I L-J'
01ING & SAFETY DEPT.
Ot . Type Gallons Min. Eff Distribution St tus
t-t-i
1 Small Gas 50
0.58 No'Pipe Insulation" V U Ne
FOR C N i
t7ATE �— By----
EnergyPro 5.1 by EnergySoft User Number: 20648 RunCode: 2013-07-11 T18.97:46—ID.-209B-J -
Page 3 of 11
PERFORMANCE CERTIFICATE: ResidentialPart 2 of 5 CF-1 R
Project Name
DICKENSON'S CAS/TA
Building Type ® Single Family O Addition Alone
❑ Multi Family O Existing+ Addition/Alteration
Date
7/11/13
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HIGH MASS Design - Verify Thermal Mass: 353.0 ft' Exposed Slab Floor, 4.000" thick at 353
The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential
Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form for each of the measures listed below for final to be given.
The Cooling System YorkCZB24.PS8Al2N40.800cIm includes credit for a 11.3 EER Condenser. A certified HERS rater must field verify the
installation of the correct Condenser.
The HVAC System HA VC incorporates HERS Venfied Refrigerant Charge or a Charge Indicator Display.
The HVAC System HA VC incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct
leakage meets the specified criteria.
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
-
FOR
EnemyPro 5.1 by Ener Soft User Number: 20648 RunCode: 2013-07-11T18:4T 4 00• 9014 G-0 Pa 4 of 11
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
DICKENSON'S CASITA
❑ Multi Family ❑ Existing+ Addition/Alteration
7/11/13
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 4.33 3.07 . 1.26
Space Cooling 99.13 92.47 6.67
Fans 20.24 24.29 -4.05.
Domestic Hot Water 60.45 60.23 0.22
Pumps 0.00 0.00 0.00
Totals 184.15 180.05 4.10
Percent Better Than Standard: 2.2%
BUILDING COMPLIES - KERB VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (N) 0deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (N) 275 31
Fuel Available at Site: Natural Gas (E) 152 17
Raised Floor Area: 0 (S) 275 30
Slab on Grade Area: 353 (W) 152 0
Average Ceiling Height: 10.0. Roof 353 0
Fenestration Average U -Factor: 0.41 ., TOTAL: 77
Average SHGC: 0.35 Fenestration/CFA Ratio: 21.9%
REMARKS
ALL EXISTING AND PROPOSED INPUT DATA USED IN THIS CALCULATION WAS PROVIDED BY THE PLANS PREPARER. ANY ALTERATION
OR DEVIATION FROM THIS CALCULATION WILL BE GENERAL CONTRACTOR RESPONSABILITY.
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company TITLE 24 OF THE DESERT
44890 EELEY DR ARMANDO CHAVEZ 7/11/13
S
Address Name '
City/State/ZipCity/State/Zip LA QUINTA, CA 92253 Phone 760 278.1840 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building enve .pe -s •
installer testing and certification and field verification by an approved HF --R S -rate . UIN
Designer or Owner (per Business & Professions Code) ���� OF � ETY DEPT.
5���"DI
Company JORGE GARCIA DESIGN AND PLANNING
/E®
1
Address 45175 PANORAMA DR SUITE A Namea ON 3
FO
City/State/Zip PALM DESERT, CA 92260 Phone (760) 272-9222 Signed License # Date
BY
Ener Pro 5.1 b Ene Soft User Number. 20648 RunCode: 2013-07-11T18:47"46 Page 5 of 11
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF-1 R
Project Name
DICKENSON'S CASITA
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family 0 Existing+ Addition/Alteration
Date
7/11/13
OPAQUE SURFACE DETAILS
Surface U Insulation Joint Appendix
Type Area Factor Cavit7yExterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof
353 0.025 R-38
0 16 New 4.2.1-A21
Slab
353 0.730 None
0 180 New 4.4.7-A1
Wall
244 0.069 R-21
45 90 New 4.3.1-A6
Wall
135 0.069 R-21
135 90 New 4.3.1-A6
Wall
246 0.069 R-21
225 90 New 4.3.1-A6
Wall
128 0.069 R-21
315 90 New 4.3.1-A6
Door
24 0.500 None
315 90 New 4.5.1-A4
FENESTRATION SURFACE DETAILS
ID
Type Area U-Factor SHGC
Azm Status Glazing Type Location/Comments
1
Window 6.0 0.400 NFRC 0.35 NFRC 45 New 2008 CEC PRESCR.
2
Window 12.5 0.400 NFRC 0.35 NFRC 45 New 2008 CEC PRESCR.
3
Window 12.5 0.400 NFRC 0.35 NFRC 45 New 2008 CEC PRESCR.
4
Window 5.6 0.400 NFRC 0.35 NFRC 135 New 2008 CEC PRESCR.
5
Vl6ndow 5.6 0.400 NFRC 0.35 NFRC 135 New 2008 CEC PRESCR.
6
Window 5.6 0.400 NFRC 0.35 NFRC 135 New 2008 CEC PRESCR.
7
Window 27.5 0.400 NFRC 0.35 NFRC 225 New 2008 CEC PRESCR.
8
Window 1.0 0.650 NFRC 0.48 NFRC 225 New WECK, GLASS BLOCK 8x8x4
9
Window 1.0 0.650 NFRC 0.48 NFRC 225 New WECK, GLASS BLOCK 8x8x4
(1) 1.1-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC HqA Wd
Ove hang Left Fin Right Fin
Len H91_ LExt RExt Dist Len H t Dist Len H t
1
Bug Screen 0.76
2
Bug Screen 0.76
3
Bug Screen 0.76
4
Roll-down Blind or Slats 0.13
5
Roll-down Blind or Slats 0.13
6
Roll-down Blind or Slats 0.13
7
Roll-down Blind or Slats 0.13
8
Bug Screen 0.76
9
Buo Screen 0.76
{
N
a L"%
40V
ffl4jG
EnerqyPro
5.1 bv EnemvSoft User Number: 20648
RunCode: 2013-07-11T18 4/^-4'6f t --1D`20 G-003a e 6 of 11
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5)
CF-1 R
Project Name
DICKENSON'S CASITA
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
7/11/13
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existing Altered Removed Volume Year Built
HAVC 353
353
3,530
Totals 1 3531 01 01 01
1
HVAC SYSTEMS
System Name Oty. Heating Type
Min. Eff. Type Min. Eff. Thermostat Type Status
HAVC 1 Central Furnace
'_Cooling
80% AFUE Split Air Conditioner 13.0 SEER Setback
New
HVAC DISTRIBUTION
System Name Heating
Duct Ducts
Cooling Duct Location R-Value Tested? Status
HAVC Ducted Ducted Attic, Roof Ins 8.0
m New
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
(Btu h)
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
No Pipe Insulation
40,000
50
0.58
n/a
n/a
New
MULTI-FAMILY WATER
HEATING
DETAILS
I HYDRONIC
HEATING SYSTEM PIPING
Control
Hot Water Piping Length
(ft)c
_ o
m
a —
S ..JTY OF FiQ
stem Nam- L n
NTA
r
Insul.
Thick.
O . HP
Plenum Outside Buried
❑
� I�aJlLuu
❑
1
❑
lO
FGG01sisiguC
nATF BY
Ener Pro 5.1 by Ener Soft User Number. 20648
RunCode: 2013-07-11 T18:47:46
a e 7 of 11
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Date
DICKENSON'S CAS/TA
7/11/13
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
§150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
§150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that due to sunlight, m e ,9QV1RmpptmNntRapceA arAxWA
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includel aa = re ar - For s- n I e e i I
conditioned space. DE TR.
Byl_SAFETY
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Ratinq and Crertifi tiprYC Y r' n.
CONSTRUCTION
FOR
EnergyPro5.1 by EnergySoft User Number: 20648 RunCode: 2013-07-11T18: 7:46 /D: 2013 -JG -003 Pagi 8 of 11
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
DICKENSON'S CASITA
1 7/11/13
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tae is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
§150(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 .
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more_thae-20-watts-of-pow a me o o
illuminated cabinet. GI-y-�/ it
Y i Y
BUILDING & SAFETY DEPT.
CPROUED
FOR CONSTRUCTION
EnergyPro5.1 by EnergySoft User Number: 20648 RunCode: 2013-07-11718:47:46 ID: 2013 -JG -003 P ge 9 of 11
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R
Project Name
Date
DICKENSON'S CASITA
7/11/13
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual-on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual-
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
EnergyPro 5.1 by EnergySoft User Number: 20648 RunCode: 2013-07-11T18:47:46 D: 2013-JG-003 Page 10 0 11
HVAC SYSTEM HEATING, AND COOLING LOADS SUMMARY
Project Name
DICKENSON'S CASITA
Date
7/11/13
System Name
HAVC
Floor Area
353
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL
CFM
264
0
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 32,000
5,184
558 135
5,311
Total Output Btuh 32,000
o
Output Btuh/ ft 90.7
299
261
Cooling System
0
0
Output per System 23,200
0
0 0
0
Total Output Btuh 23,200
0
558
0
Total Output ons 1.9
299
261
Total Output Btuh/s ft 65.7
Total Output s ft/Ton 182.6
1 5,783
5,833
Air System
CFM per System
800
HVAC EQUIPMENT SELECTION
Airflow cfm
800
YorkCZB24.PS8Al2N40.800cfm
16,285 3,503
32,000
Airflow cfm/s ft
2.27
Airflow cfm/Ton 413.8
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
16,285 3,503 32,000
Aug 3 PM Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 68 OF
Outside Air Ar
0 cfm Supply Fan
800 cfm
68 OF
68 OF 105 OF
Heating Coil
-- --
105 OF
R0Oit.i �
68 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 75/62°F 75/62°F 56/55°F
NL!°
Outside Air
0 cftn Supply Fan Cooling Coil
800 cfm
°
75 / 62 F
7T�
TY QU.l ` 5T °
CITY i ®�d ..........................
BUIL®li`a�'33 4 0
APFM°
! R CONSTRUCTION / s2
BY
EnergyPro 5.1 by EnergySoR User Number: 20648 RunCode: 2013-07-11718:47:46 ID: 20 - age 11 of 11