Loading...
0005-261 (AR)LICENSED CONTRACTOR DECLARATION 11 hereby affirm under penalty of perjury that I am licensed under provisions of Chaffer 9 (commencing with Section 7000) of Division 3 of the Business and Professionals .Code, and my License is in full force and effect. License it Lic. Class Exp. Date B 7/3112( Date Signature Signature of Contrac"tor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or.offered for sale (Sec. 7044, Business & Professionals Code). - ( ) 1, as .owner- of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044,; Business & Professionals Code). () I am exempt under Section B&P.C. for this reason Date. Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby:affirm under penalty of perjury one of,the following declarations: (.) I have and:will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of'the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section •3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier STAT FUND ' - Policy No. . 046409W3 (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I:.shallnot employ any person in any manner so as-t6lb ceme subject to the :workers' compensation laws of California, and agree that ifIl should become subject to th�'workars' compensailon provisions of Section 3700 of•-th Labor Code, lsh IT...fo� (with comply with those�pro jsl S. .Date:' Applicant i 1 Warning: Failure to secure Workers' Compensation coverage is unlai ful and' shall subject an employer to criminal penalties and civil fines up to $100,000, in' r addition to the cost of compensation, damages as provided for in Section 3706 of the LaborCode, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit -subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at, -whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit.issued as a result of this application becomes null and void if work is not commenced within 180 days from date of" issuance of such permit; or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply wit�fl-Cfty�and State laws relating to the building construction, and hereby -at honze reprfesentatfves of this City, to enter upon flie above-mentioned property for inspectlo purpos/es. ) n ,Signature (Owner/A etUj�f� g L ater41/- BUILDING'PERMIT PERMIT# f1t10�-lf�l, " DATE / VALUATIONLOT TRACT ,0' 57 2930 JOB SI YE,;_ ADDRESS 48.747 V.I'S'I'A k'AL-OAii 6 APN OWNER CONTRACTOR/DESIGNER/EN (NEER TIS i FAWRTD i'T SPARKS ARKS C BOX g}yC�:"d�,I�+�')PUE 9-2295 ��CS�i/�•i��i �'iL�tTAG"I701�4PO TTA DIj LAQ1'vTII4`1A 92.253 LAQlM fA CA 92253 (760) 7'71-1941 C -SU 2996 USE OF PERMIT REMD)WLAL ADVInON SUPPI,.tIM1134TALI'D PERMIT4000.24037,.EililIN CUSTOM DOUBLE OUEST SUITE (100 SF).113 LIEU OF fI1`ANDARTD GUMOT SUITE (AA :1n DUR1140 Cr-T143TRUC UYN. CUSTOM CONSTRUCTION 6$2.00 OF GARA09 211.00 Sly FS":L•f M'lCXI) C09' Or, CON 2UC'nQX . .54,9,26.40 1'i3:1 m r,m gfT.I n"Ry y F'LA31 CHECK "11 361-/0000091118 $349,09 C0106 -,f RUCTION P'EE 101-000.448'000 34"47.00 MECHANICAL FEE 101.000-421.000 $46,00 ELECTRICAL FEE 101-000-420-000 $41.04 I'Lum"aTf oFES? 101.000-4'19-000 €38.$0 S l'RO'Na MOTION FEE = RESID -101-000-241-000 $5.41 c3RADiNG PER, $20.00 e" ART IN PUBLIC PIACES - WES1I 70-1-000-255.000 ¢13.7.32 R�i A 3�a 00.0 M&MU C -710N. ANl PL.A14 Ci*,Cr,: $1;095.4-1 1263S PRE-PAU) IFESS IF $0,00 TQl'.A11 P]ijaffr IMES DUE.NOW RECEIPT DATE BY 'r Jw/ DATE FINALED INSPECTOR V INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR s BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Forms & Footings _ % �. Underground Ducts Ducts Sleh Grade �y/� Retum Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap F.A.U. Framing D Z " Cp Compressor Insulation _ap Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath , Final Final POOLS - SPAS BLOCKWALL APPROVALS Steel - Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment. Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Sewer Connection �� Pool Cover Encapsulation Gas Piping Gas Test Appliances Final COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) !fit �iJ•7 t , � f `.. , - . o � - - � '. _ .� Bltti :City of La Quinta g Tiding a[ Safety Division P.O. Box 1504, .� - - t• 78=495 Calle Tampico • Permit # - Quints •CA 92253 Building -Permit Application and Tracking Sheet �'.,�• „ , -. . Project Address74 7 !J%STi4 4; ' Owner'sName: �,• i; . p D .'{g J Addttiss. �j A. P. Number: (� I O O O O Cp h _ Description: �� LO % S 7. City,ST. Zip: C , C-4. - .• `:;:..., x Leval - Telephone: Contractor: pjC ' Projeci Descnpuon Address: OJ3t-� G✓fS'7' S.j/7 .. Cit`.ST. Zip:. CA •r • - n/ Z/ /LQJ /clJj C y Telephone: * #: Z% 9 �o 2� i77�% State Lic. # : w 7 o .%• City Lic. ry 037 _ Arch..Engr..Designerf( L.lir1�4'`'a/y-2rl-. 5YIWt ' 1 ' ' ; _ • , _ -. Address: , , > . _ Cin:. ST. ' Zip: , • _ Occupancyon Con sau cn~T { Telephone: - - - - - Alter R air Demo Ad do Al ,in le one New eP Pro J tYP e c State Lic. 0: F s '`Sq. Ft : l 0 30. • # stories: # Units:,.,, Name of Contact Person: 7/ [K� Est[tnated slue of Proi 2. . - Contact Person: Tele hone - f Conta .....::::::::::.: iiii:•ii'F. ii:v}:i::i: i:•i?ii •ii ii$ii ....:::.........::.... . :•:...............::.:::: •.... _:..:::.:..::......::....,.,....:.::.:..:':::•.:'� :.:::::::. ,....:.:..: ,... ..,:?::� ;•:, iiia:::::: .................:::: v...... : .i' . .. :.. .... .,. .... � ': Ei�.•i�:�FV.::}7,!�...:::'i::::ij};•`:.i:5?•}:::.�: tir :rivi•i........, ;.;:.;.,...::::•::: ...... ::::::....: .: •.::::: •: :•:::::::::::::.ai:•aaii:•iii:?:iii}i:IX?i<;?;^:'>[i�iii:iii iiii::v:'•ii::::?iaY::.i'.... .: :•: vi'^:;•}.w;; •. :... . is}i.... _ .... .:�}iii: �:::.'?:;i:.::::::::•:: i::: •::::::::{: {•i •:vw•; ... ..... �•���..... :... ...... ............ 9 ................ .............:::...... Submittal ...::::...:...:.. .. .......:........................ .............,..- ,.......__,..._...................�.:.A.}i:a.:i:iii::<�:.:•:::•}..,...::.::::::::<:;;.::ititem<:;>::<::i:;;.}s.ii:•}ii:<i<«:::i::<i�; :: y'l.;{??•iii:a:^ii:•i"';:•: .:::::....... - .. ... ..:. :C:?•a}ay::::: ........ ::: ;avii:Y>yrJ i\CiuiiJ�}: ��i .{4 a?: ii:{,:f': a> .:..»:fs::>:Jlwegath<:�,�.=`'} M; A!u Ar • 'k U CIA Irk op r O6 3 O VD �`G Desert Sands Unified School District 47-950 Dune Palms Road Notice: La Quinta, CA 92253 ` Document Cannot Be Duplicated 760-771-8515 CERTIFICATE OF COMPLIANCE Date 7/20/00 - APN # 649-100-006 No.• 20748 - Jurisdiction La Quinta Owner NameTD Desert Development Permit #' No. 'Street r see below Log # City La Quints Zip 92253 ,J Study::Area Tract # Lot # 57 & 59 ' Square Footage 1304 'F -Type of Development Single Family Residence No. of Units' 2 Comments Custom Construction Residential Addition - 8=744 Vista Palomino lot 598q. Ft. 652 8-747 Vista Palomino lot 57 Sq; Ft 652 Total of 1,304. Sq. Ft. =, $2,673.20 CC Palm Desert Nat'l Bank - - At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures o'r replacement mobilehomes. It . has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: - Add. of Sq. Ft. to New, Construction EXEMPTION NOT APPILICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 2.05 X ` 1,304 or $ 2,673.20 the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this.proposed project may now be issued Fees Paid By CC Plam Desert National Bank/Norma Maine Telephone,•4771-1941 •, Name on the check:, r j r dam; ` By Dr. Doris. WilsonTt •'� . Superintendent, Fee collected /exempted by Ellen Patino Payment Received $2,673.20 Check No.. 081298 Signature C/ y 10T10E: Pursuant of Assembly Bill 3081 (CHAP 549, STATS. 1998) this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or Installation permit for this project is sssued or on which they are paid to the Distrlct(s) or to another public entity authorized to ollect them on the District('s)(s) behalf, whichever is earlier. Collector: Attach a copy of county or city plan check application form to district copy. for all waivers. Embossed Original= Building DeptJApplicant Copy - Applicant/Receipt Copy - Accounting AUG -03-2000 23:44 RANCHO LA.QUINTA 7777750 '.'P.01 Certified to be '8 true. and 4*rrect . ropy Of -THE ORIGINAL. _ jeearded - AMUST 4_ , - 2000 Q LE BY1.S Instrument No. 2000-302882 . RECORDII�C official Records oiRZvE�tsiDty. ti City of.La QuWa 'ounty. CaGfvmia Community Devdapraml Departmmt 'Y - 92?33 `PIDEUTY ATIONAL TITLE LO., La Quintj� CAWEEN RECORDS PLEASE MAIL TO: city of La Questa 0 Community Developmw Dept e/o CAB Trousdeli _ p.0. Box 1504 . La Quint&, CA 92253 C..OVENANTAND A� � MS�CTING'THE USE OF TEM RESIDENCE A,T- - 7a7�YLS`f,A PsLO :LA QVIIV TA=CALIFORNz ► This and woe= is made and executed on this the 20t°. day of July, 2000, by T. . D. Desert Dev�elapment, L- for *Pe6Y heseia..11se City of La Qui , a Municipal • Corporation, is hereby made a pally to this ag�oetttear fore purposes set forth beioN►_ is the property owu The undatpod heitby certifies bast he er of the follm�►itag descabed rzal property in the City of Lz eta• COUM of Rivtrside� State of California: • Lot 57 of lud No. 29306'in the City of La Quinta, County. of Rivti$ide In ccmtidetalion offt a City of La Quiuta issuing a building *Mdt far cerin improve meats which "will be cora =ed on said pwpe�', the widetsiped does hemby covenant and agree to and with said City to restrict the use of said propertY as follows: 1. The guest house may not be rented nor sold iudependent of the main sink family residenee {Minor Use Permit No. 2004-227) y 2, ;'1\10 kitchen or cavking facilities shall be constructed ila the Post hoose Per.the provisions b{Ciapters 9.30.1130 (RL Zme Distict) and•9.60.100 (Guest Houses) of - the La Quin Municipal Code; and, 3.. Allon-site facilities am intended for the sole occupancy of the prcpetty owner(s). nonpaying guests, and domestic employees. , Tbis covenant and ageecacnt shall r" with the laud and shall be hinging upon futuxe °'� _ their successors; heirs, or asmgns, and ouzselves; and shall continue in effect while said accessary building remains on the reel gcnrpCly orunless 00mWise released by the y of the City of La. Quints, All leases of said dwelling andlor propertY shall be subject to this restriction 'Fttis C0vww -p PZ -04-2000 10: 22 f D w CD O 5 m CD ro p w CD • P.O. BOX 1504 TEL 760-777-7012 78-495 CALLE TAMPICO INSPECTION REQUESTS LA QUINTA, CALIFORNIA 92253 760-777-7153 ���3❑��ocm�omwmS�mm�muo mmmancni❑N❑mQm•v=ucii.3vNm�+'vcmw,�nro maO'�mm �wa..-I ^yCa3naca�orro �mrywrH Cw P roW- na1.m 0-n?- 3. '- ° mm CD (D ❑wm (D wmy4m0 ro- w"- ma oN° Ce] [D 0 ° p n r to w O T mvwT° D O- p U., a=O CDm3C7 N n CD D oT m�-ZI HcowooN°3°a Z'Ll �°m -3�a3 °a3a�O c�QQow mmk: cv ORao4o°�3- m n❑o co Q0 w ='- m > D'oq oCL CD a❑ ¢� u'mmrCn com tD nc n Cl) CD &nn m w �m c ch c) s° C)❑ n 5 0 CD o�row o ❑m m w o 3 0 � �ronm0 -❑78Omm o opC mwZ ?aw3u�o0 cm p n °' N ro ❑ o ❑ mn Z tdmm�ua❑ an z in CD CL 71 m� ro_D��� omN� ro W wc0w°� _ m -CD o'n Cw0 �❑❑❑ y�m ow 3a0 y�°°v m o �ro mmm Zp v c om 3n o ra 'z❑3C3pmowsi �faro a um CD m ' ro" r3Cwun mw m CD om !/f� 3O-a Q CD D CD. _. -ch CD 0 I co m m v m n m m Q w � m m o m W N g c ro o n ro m ❑ Z a p DI CD m W o _c ww mo3=1 - W m 4w� r� �o qm way _I w _� ❑w 3 ❑ O c7o 3_Nmyyba Nc. ocro y=3v' zaro om❑ O m ❑ ao m~�aZ a 4 rn m 1' cr S� F [D c Z ? Sao CD m �x ro ro m C a 0 510 7 =° N 0 Q y 4 O N O m C1. O w 0 03 CD O w A w m m 8 3 w CCD H+ 7 O CS Co 2 Cro1 N 5 , j O m y O 7 [D a ro C 7 w a N ..4 w cp — tp m N CD 6 m❑ D_ fl ro Q ° C_ y (� P7 m O mac?' �om�� �� roc rno� Qom aFw o� ay n wN m c W Q Ai o c m � o j y �n Et O N � �� �, ? �� m a �' i3n < rn� a ° CD m OL m m.c CD m w w a m cn r. ao n c iTo- r- a Ti rb - [/] O FLj m v -w3 r Cam" O d� C O to �� 0� �� � ��CZ �oC� �.�y � � r � � trJ �1 cn V- � or d v inn r O .,y r� T `j >W C m O n t4 C+] 0 z 0 H O C tit r'-3- La , j O � d 000v0000 ' >o d x M w b � 0000000o a� r' 0 0 0 0 0 0 0 0 C] G N 0 0 0 0 0 0 0 0 O w G t4 t4 4L� 4- 4L � d w ii '.A P. NN -W 4A W •.+ 1D O - T T H O 00 00 66 OW U'Q O 0 0 0 0 0 0 0- Y a n ^ D 00 0000 O� (] D tj CD 7, oo •� aa��if O --i b Kam] �. ft/ti v Z s�j Co.[] 1 m m 7' '� Q , o p G) ro [[ii77 0 Z r G¢ m N i , N f; o t 0 C=7 !'� R D H td !�' ,uh PDo w 0, �i p z �i 4 I� z w o a a o CD Co. CCD c i o %o 0 0 a Cr1 m x �m c O h+ m tj Fes+ U kO W W �JI 64 U N k n TITLE 24 REPORT Title 24 Report for: MONTANA GUEST HOUSE 3 (1030 Sq Ft) Various Lots, Rancho La Quints La Quinta,, Ca. 92253 48.7407 i% M 7401ANSW .s Project Designer: SPARKS CONSTRUCTION 79-295 Rancho La Quinta Drive La Quinta; Ca. 92253 (760) 771-1941 ., Report Prepared' By: t R. KROWN CEA R98-93-204 KROWN MECHANICAL DESIGN 34332 LAURA WAY RANCHO MIRAGE, CA 92270 (760) 770-0044 Certified Energy knelyst Ford F. Krown ; NR 9"M' r rR 88.83.204 r / CAOEC Cc�osr>Zo ion ct. Duibc#r►g Erwgy CxeuLont ' • 1i,h Alw,her•- C� 'j I The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has a oval and is' j authorized by the California Energy Commission for use with both the Residential and Nonresidential 1998 Building Energy Efficiency Standards. Thisram developed ped by Gabel Dodd/EnergySoft, LLC (415) 883-5900. l i � EnergyPro 2.1 By EnergySoft Job Number: 00028GH User Number: 2366 I 4 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R MONTANA GUEST HOUSE 3 (1030 Sq Ft) .5/4/00 Project Title'. Date Various Lots, Rancho La Quinta La Quinta Project Address Building Permit # KROWN MECHANICAL DESIGN (760) 770-0044 Plan Check I Date Documentation Author Telephone Computer Performance 15 Field check I Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1,030if Total Conditioned Slab Area: 1,030f? Building Type: ° (check one or more) ® Single Family Detached (SFD) ❑ Addition Alone ❑ Single Family Attached (SFA) ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation:' All Four OrientationS Floor Construction Type: Slab Floor .Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor BUILDING SHELL INSULATION Const. ; Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Tile/Attic/R38/Gyp Wood 0.029 Exterior Roof R-13 Wall w/1-1/16 Falcon Foam Wood 0.060 Exterior Wall Solid Wood Door Wood 0.387 Exterior Door R-13 Partition Wood 0.085 Exterior Wall FENESTRATION Shadina Devices Type Orientation Area Labeled Fenestration Interior Exterior Overhang Side Fins SF U -Value SHGC roller blind etc. shadescreen, etc. Yes / No Yes / No Front 35.0 0.48 0.44 Drapery Bug Screen u ❑ ❑ x❑ Front 30.0 0.49 0.44 Drapery Bug Screen lx:l ❑ ❑ x❑ Rear 16.0 0.57 0.63 Drapery Bug Screen x❑ ❑ ❑ x❑ Right 30.0 0.49 0.44 Drapery Bug Screen �� ❑ ❑ �� F ❑ ❑❑ ❑❑..❑❑I ❑❑ El 1Li �I I 1701❑L f I i i { Ll Run Initiation Time: 05104/00 08:33:15 Run Code: 957429195 IEnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00028GH Page•3 of 21 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R MONTANA GUEST HOUSE 3 (1030 Sq Ft) 5/4/00 Address: 34332 LAURA WAY Project Title Date Telephone: (760) 771-1941 HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Lic. #: Distribution Heating Equipment Minimum Type and Duct or '00 Type (furnace, heat Efficiency Location Piping Thermostat Location/ Enforcement Agency pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Cpntral Fiimanp. 80% AFUE Ducts in Qttic 42 Setback Fum-A/C-1A 8 1 B Address: Cooling Equipment Minimum Duct Telephone: Type (air conditioner, Efficiency Location Duct heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Thermostat Location/ Type Comments Split Air Conditioner 11.0 SEER Ducts in Attic 47 Setback Fum-A/C:-1 A R 1 R WATER HEATING SYSTEMS Rated 1 Tank Energy Fact. 1 External Water Heater Water Heater Distribution # in Input System Name Type Cap, or Recovery Standby Tank Insul. :Type Syst. Btu/hr (gal) Efficiency Loss R -Value AM RI .AN-75M:4N Small Gas Standard 1 57,000 _ 5 0-51 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS :OMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to compty.with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: R. KROWN CEA R98-93204 Title/Firm: SPARKS CONSTRUCTION Title/Firm:. KROWN MECHANICAL DESIGN Address: 79-295 Rancho La Quinta Drive Address: 34332 LAURA WAY ,La Quinta, Ca. 92253 RANCHO MIRAGE, CA 92270 Telephone: (760) 771-1941 Telephone: (76o) 7700044' Lic. #: '00 (signature) (date) l nature)r (date) Enforcement Agency Name: Title/Firm: Address: Telephone: EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number. 00028GH Page:4 of 21 1 Certificate of Compliance: Residential (Addendum) CF -1 R MONTANA GUEST HOUSE 3 (1030 Sq Ft) 5/4/00 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the,performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies ..ate........ ...4UaUy W....0 apc.1a1 Juszmcauon ana aocumentauon suDmrr[ea. Plan Field The DHW System."AMERICAN G62 -75T57 -4N" Energy Factor= 0.510. An EF below 0.58 requires an R-12 External Blanket. HERS Required Verification ' These features must be confirmed andlor tested b a certified HERS rater under the supervision of a CEC approved HERS —4,1— Th. 41CGC r��e. .......� d.............� �..., �.._-:a__a:__ Run Initiation Time: 05/04/00 08:33.15 Run Code: 957429195 EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number. 00028GH Page•5 of 21 Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist Is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component specifications. LDESCRIPTION Instructions: ,Check or initial applicable boxes or enter NIA if not applicable. DESIGNER IENFORCEMENT Building Envelope Measures IN 1 '§ 150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. § 150(b): Loose fill insulation manufacturer's labeled R -value. FX1I1 1150(c): Minimum R-13 wall insulation in framed walls or equivalent U -value (does not apply to exterior mass walls). -§ 150(d): Minimum R-13 raised floor insulation in wood framed floors. El§ 150(1): Slab edge insulation - water absorption rate < 0.3%, water vapor transmission rate < 2.0 punch. �. §118: Insulation specified or installed meets quality standards. Indicate type and form. Ful JAI §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfittration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Manufactured fenestration products labeled with certified U -value, SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs: 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. ace Conditioning, Water Heating and Plumbing -System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be edemally wrapped with R-12: 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation, piping between heat source and tank insulated. 3.Insulation on the first 5' of pipes closest to water heater tank, non -recirculating systems (R-4 or greater), buried or exposed piping in recirculating sections of hot water systems, cooling system piping below 55 deg F. . `§150(m): Duets and Fans 1. All ducts and plenums constructed, installed, insulated, fastened, and sealed to comply with the ICSO 1997 UMC sections 601 603; ducts insulated to a minimum installed R-4.2 or ducts enclosed entirely within conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct closure system that meets the applicable requirements of UL181, UL181S, or UL181B and other applicable specified test for longevity given in 150(m): 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems servng conditioned space have either automatic or readily accessible, manually operated dampers. §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no pilot or electric resistance heating. 2. System is installed with at least 36" of pipe between filter and heater, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Central Furnaces, pool heaters, spa heaters or household cooking appliances have no constant pilot.light. ghting Measures §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumensA att or.greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. I i I , 150(k)2: Rooms with a shower or bathtub, must either have at least one luminaire with lamps with an efficacy of 40 IumensMratt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in 150(k)2.; and recessed I ceiling are IC (insulation cover) approved. !EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00028GH Page:6 of 21 f Computer Method Summary (Part 1 of 3) C -2R MONTANA GUEST HOUSE 3 (1030 Sq Ft) 5/4/00 Project Title Date Various Lots, Rancho La Quinta La Quinta Project Address Building Permit # KROWN MECHANICAL DESIGN (760) 770-0044 Plan Check/Date Documentation Author Telephone Computer Performance 15 Field Check/Date Compliance Method (package orComputer) Cimate Zone Source Energy Standard Use (kBtu/sf-yr) Design Space Heating 5.87 Space Cooling 51.65 Domestic Hot Water 20.74 Totals 7&26 Facing North Margin 1 Facing I East Margin Facing South Margin Facing West Margin 01M. R-11,1R.—Mvem 6.45 -0.58 39.75 11.90 21.46 -0.711 5.09 0.78 47.17 4.48 21.46 -0.711 4.23 1.64 45.98 5.67 21.46 -0.71 5.51 0.36 45.14 6.50 21.46 -0.71 6765 10-60 73-72 4,541 1 71.67 6591 7211 BUILDING __L15 COMPLIES This C -2R summa es the results of a four cardinal orientation analysis. The pages that follow describe the front facing North occurence. This plan has been analyzed with identical features in all orientations. GENERAL INFORMATION Conditioned Floor Area: 1,030 Floor Construction Type: X❑ Slab Floor Building Type: Single Fam Detached ❑ Raised Floor Building Front Orientation: All Four Orientations Number of Dwelling Units: 1.00 Total Conditioned Volume: 10,300 Number of Stories: 1 . Slab Floor Area: 1,030 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area Rum -A/C -1A P, 1R 1, if) i m Cnnditinnad Spthack n/a OPAQUE SURFACES Solar Act. Gains Type Area U -Val. Azm. Tilt Y / N Form 3 Reference Location / Comments Run Initiation Time: 05/04/00 08.33.15 Run Code: 957429195 EnergyPro 2.1 By EnergySoft User Number. 2366 Job Number: 00028GH Page:7 of 21 MNSIGINTFINTINFRA 01M. R-11,1R.—Mvem MMKILYFEWUMFIR.-Mrr. "a �11111111[eil MEMO ■ ■ ■ ■ Run Initiation Time: 05/04/00 08.33.15 Run Code: 957429195 EnergyPro 2.1 By EnergySoft User Number. 2366 Job Number: 00028GH Page:7 of 21 Computer Method Summary (Part 2 of 3) C -2R MONTANA GUEST HOUSE 3 (1 030 Sq Ft) 5/4/00 Project Title Date FENESTRATION SURFACES U -Value Act. Glazing Type Location/ # Type Area SHGC Azm. Tift Comments L Window Front (North) n n 4M p 44 n �c Pacific 10rin 6ron7e I CT HnI IS 2 Window Front - (Northeast) 30.0 0.490 0.44 45 90 Pacific 1000 Bronze GUEST HOUSE 2 Wiridow Rear (South) 16.0 0.570 0.63 180 90 Glass Block Default GUEST HOUSE 4 Window Right (Northwest) 30.0 0.490 0.44 315 90 Pacific 1000 Bronze GUEST HOUSE INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Interior Shade Type SHGC Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. L6Q. REQ Dist Len Hgt Dist Len Hgt 1 Drapery 0.68 Bug Screen 0.76 5.0 3.5. 2.0 2.0 2.0 2.0 2 Drapery 0.66 Bug Screen 0.76 6.0 5.0 2.0 2.0 2.0 2.0 _ 3 Drapery 0.68 Bug Screen 0.76 2.0 4.0 2.0 2.0 2.0 2.0 _ 4 Drapery 0.68 Bug Screen 0.76 6 0 5 0 20 2.0 20 2.0 _ - - - Run Initiation Time: 05/04/00 09.33.15 Run Code: 957429195 EnergyPro 2.1 By EnergySoft User Number. 2366 Job Number: OOD28GH Page:8 of 21 Computer Method Summary (Part 3 of 3) C -2R MONTANA GUEST HOUSE 3 (1030 Sq Ft) 5/4/00 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 2O 0.76 0.0 0 GUEST HOUSE HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location/ pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4-2 Setback Fum-A/C-1 A & 1 B Hydronic Piping Pipe pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Air Conditioner 11.0 SEER Ducts in Attic 4-2 Setback Fum-A/C-1 A & 1 B WATER HEATING SYSTEMS Water Heater System Name Water Heater Distribution Ratedl Tank Energy Facts 1 Tank Insul. # in Input Cap. or Recovery Standby R -Value Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. AMERICAN G62 -75T57 -4N Small Gas Standard 1 57,000 75 0.51 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS EnergyPro 2.1 By EneroySoft User Number 2366 Job Number: 00028GH Paae:9 of 21 Computer Method Summa (Addendum) C2 -R MONTANA GUEST HOUSE 3 (1030 Sq Ft) 5/4/00 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local - enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies -- --•• -••- 4—Y .......o .-#—a. Jwuncduun dim uocu"mmaiion suomirtea. _ Plan Field The DHW System "AMERICAN G62 -75T57 -4N" Energy Factor = 0.510. An EF below 0.58 requires an R-12 Extemal Blanket. tS Required Verification ;e features must be confirmed andtr tested b a certified HERS rater under the supervlsioo of a CEC approved HERS yy idac Tho MFRC roar moat .1n......e..� ��. a !.. �:a-_"-_ __J Ja___--.._ ._ _.._ _ _- - ----- - .- .._._ _...._...._.. •..........y...,...... ....y ....•.w� n.caau.cs un a luno �.r�rt. Plan Field Run Initiation Time: 05/04/00 08:33.15 Run Code: 857429195 EnergyPro 2.1 By Energysoft User Number: 2366 Job Number: 00028tH Page: 10 of 21 f PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE MONTANA GUEST HOUSE 3 (1030 Sq Ft) 5/4/00 W DESCRIPTION .o W 1 I Roofing, Asbestos -Cement Shingles H y � Z O — SKETCH OF ASSEMBLY ASSEMBLY NAME Tile/Attic/R-38/Gyp ASSEMBLY ❑ Floor TYPE n Wall (check one) Ceiling / Roof FRAMING MATERIAL Wood FRAMING % 10% Framing % 16%(16" o.c. Wall) 12%(24" o.c. Wall) 10%(16" o.c. Floor/CeiL) 7%(24" o.c. Floor/Cell.) SUBTOTAL R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 I Roofing, Asbestos -Cement Shingles 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Air Space 6 Insulation, Mineral Fiber, R-38 6 Gypsum.or Plaster Board 7 0.00 8 3.86 s 1.39 2.081 INSIDE SURFACE AIR FILM ASSEMBLY NAME Tile/Attic/R-38/Gyp ASSEMBLY ❑ Floor TYPE n Wall (check one) Ceiling / Roof FRAMING MATERIAL Wood FRAMING % 10% Framing % 16%(16" o.c. Wall) 12%(24" o.c. Wall) 10%(16" o.c. Floor/CeiL) 7%(24" o.c. Floor/Cell.) SUBTOTAL R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.210 0.210 0.060 0.060 0.620 0.620 0.800 0.800 38.0001 11.385 0.450 0.450 0.00 0.00 3.86 0.36 1.39 2.081 0.610 0.610 40.92 ' 14.31 Rc R A `HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F4b) HC (A X B) (Btu/F-sf) members. 0.0244 2.50 0.24 0.60 0.06 0.351 0.02 1.42 0.291 0.41 0.00 0.00 0.00 3.86 0.36 1.39 2.081 0.26 0.54 g g TOTAL HC 3.0 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. 0.0244 X 0.90 + 0.0699 X 0.10 = 0.029 11 Rc 1 - (Fr0/6/100) 11 Rf Fr%/100 ASSEMBLY U -VALUE i EnergyPro 2.1 By EnregySoft User Number. 2366. Job Number. 00028GH Pagel l of 21 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE MONTANA GUEST HOUSE 3 (1030 Sq F0 5/4/00 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 ASSEMBLY NAME IR -13 Wall w/1-1/16 Falcon Foam Insulation, Mineral Fiber, R-13 5 ASSEMBLYFloor 6I 0.05 7 TYPE (check one) Wall 2.081 0 W Ceiling / Roof INSIDE SURFACE AIR FILM 0.680 NFRAMING MATERIAL Wood Z O FRAMING %o 15 �o Framing 12.4 TOTAL HC 15%(16" o.c. Wall) 12%(24" o.c. Wall) 10%(16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7%(24" o.c. Floor/Ceil.) SUBTOTAL R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Falcon Foam 4 Insulation, Mineral Fiber, R-13 5 Gypsum or Plaster Board 6I 0.05 7 0.371 8 2.081 9 0.54 INSIDE SURFACE AIR FILM SUBTOTAL R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.175 0.175 0.0601 0:060 4.675 4.675 12.999 3.465 0.450 0.450 0.05 1.68 0.371 0.62 2.081 0.261 0.54 0.680 0.680 1 19.211 9.68 rcc KT A -HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) members. [ 0.0521 8.461 0.20 1.69 0.06 0.35 0.02 0.16 0.29 0.05 1.68 0.371 0.62 2.081 0.261 0.54 12.4 TOTAL HC 2 9 NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0521 X 0.85 1 + 0.1034 X 0.15 1 = 0.060 1 / Rc' 1 - (Fr%1 100) 11 Rf Fr0/6/100 ASSEMBLY U -VALUE .o.yyr.v c.. aay oucyyoun +ser rvumoer. LOW JOb NUMDeC 00025UN Page: 12 of 21 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE i MONTANA GUEST HOUSE 3 (1030 Sq F0 I 5/4/00 COMPONENT DESCRIPTION DESCRIPTION 4MING OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Membrane, Vapor -Permeable Fell 3 ASSEMBLY NAME IR -13 Partition Gypsum or Plaster Board 5 ASSEMBLY Floor 0.62 7 TYPE (check one) XWall P W W Ceiling /Roof INSIDE SURFACE AIR FILM 0.680 NFRAMING MATERIAL Wood . Z FRAMING % 15 % . Framing 6.4 TOTAL HC 15%(16" o.c. Wall) . 12%(24" o.c. Wall) 10%(16" o.c. FloorlCeil.) SKETCH OF ASSEMBLY 7%(24" o.c. Floor/Cell.) R -VALUE DESCRIPTION 4MING OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Membrane, Vapor -Permeable Fell 3 Insulation, Mineral Fiber, R-13 4 Gypsum or Plaster Board 5 1.68 6 0.62 7 0.26 8 9 INSIDE SURFACE AIR FILM R -VALUE THICK- NESS (in.) 4MING n ❑ ® ❑ El El❑ 0.170 0.625 0.010 3.500 0.500 12.9991 3.465 0.4501 0.450 1.68 0.37 R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.5621 0.562 0.0601 0.060 12.9991 3.465 0.4501 0.450 1.68 0.37 0.62 2.08 0.26 0.54 0.6801 0.680 14.921 5.39 Rc R 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F4b) HC (A X B) (Btu/F-sf) members [ 0.0670 2.601 0.261 0.68 0.061 0.351 0.02 1.68 0.37 0.62 2.08 0.26 0.54 6.4 TOTAL HC 1 9 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members [ 0.0670 X 0.85 1 + 0.18561 X F 0.15 1 / Rc 1 - (Fr -/61 100) J 1 / Rf Fr%l 100 ASSEMBLY U -VALUE i I i I EnergyPro 2.1 By EnregySoft User Number: 2366 Job Number: 00028GH Page: 13 of 21 INSTALLATION CERTIFICATE (Part 1 of 7) CF -6R Site Address Permit Number An installation certificate is required to be posted at the building site or made available for all appropriate inspections. (The information provided on this form is required; however, use of this form to provide the information is optional.) After completion of final inspection, a copy must be provided to the building department (upon request) and the building owner at occupancy, per Section 10-103(b). HVAC SYSTEMS: Heating Equipment Equip. # of Efficiel cy1 Duct Duct or Heating Heating Type (pkg. CEC Certified Mfr Name Identical (AFUE etc.)) Location Piping Load Capacity heat pump) & Model Number Systems [>='CF -1 R Value] (attic, etc.) R -Value (Btu/hr) (Btu/hr) Cooling Equipment - Equip. CEC Certified Compressor # of Efficiency' Duct Cooling Coolingg Type (pkg. Unit Mfr Name & Identical (SEER etc.)) Location Duct or Load Capacify heat pump Model Number Systems [>= CF -1 R Value] (attic, etc.) R -Value (Btu/hr) , (Btu/hr) 1. — reads Greater Than or Equal to. I, the undersigned, verify that equipment listed above is: (1) the actual equipment installed; (2) equivalent to or more efficient than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) the equipment meets or exceeds the appropriate requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable. Signature, Date Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner WATER HEATING SYSTEMS: CEC Certified, Distribution If Recir- # of Rated2 Tank Effie 2 External Heater Mfr Name Type(Std, culation, Identical Input (kW Volume ciencv Standb Insulation Type & Model Number Point -o -Use) Control Type Systems or Btu/hr) Gallons (EF, RE) Loss (%� R -Value 2 For small gas storage (rated input of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list Energy Factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Recovery Efficiency, Standby Loss and Rated Input. For instantaneous gas water heaters, list Recovery Efficiency and Rated Input. 3 R-12 e)demal insulation is mandatory for storage water heaters with an energy factor of less than 0.58. Faucets & Shower Heads: All faucets & showerheads installed are certified to the Commission, pursuant to Tide 24, Part 6, Section 111. A I, the undersigned, verify that equipment listed above my signature is: (1) is the actual equipment installed; (2) equivalent to or more efficient than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) equipment that meets or exceeds the appropriate requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable. Signature, Date Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00028GH Page: 14 of 21 i INSTALLATION CERTIFICATE (Part 2 of 7) CF -6R Site Address Permit Number FENESTRATION / GLAZING: Product U- Product ` Interior or Value' . SHGC' Exteror Shading (=<CF -1 R (=< CF -1 R # of Quantity Square Device or Comments/ Manufacturer/Brand Name value)2 value)' Panes (Optional) Feet Overhang Special Features GROUP LIKE PRODUCTS 2. 3. 5. 6. 7. 8. - 9 f 10. _ 11. 12. 13. 14. 15. 1. Manufactured Fenestration products use the values from the product label. Field fabricated fenestration products use the default values from Section 118 of the Energy Efficiency Standards. 2. Installed U -value must be less than or equal to values from CF -11R. Installed SHGC must be less than or equal to values from CF -11R, or a shading device (Interior, erderlor or overhang) Is installed as specified on the CF -11R. Alternatively, Installed weighted average U•values for the total fenestration area are less than or equal to values from CF -1R. I, the undersigned, verify that the fenestration/glazing listed above my signature (1) is the actual fenestration product installed; (2) is equivalent to or has a lower U -value and lower SHGC than that specified in the certificate of compliance. (Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) the product meets or exceeds the appropriate requirements for manufactured devices (from Part 6), where applicable. Item #s Signature, Date Installing Subcontractor (Co. Name) (if applicable). OR General Contractor (Co. Name) OR Owner OR Window Distributor Item #s Signature, Date Installing Subcontractor (Co. Name) (if applicable) OR General Contractor (Co. Name) OR Owner OR Window Distributor Item #s Signature, Date Installing Subcontractor (Co. Name) (if applicable) 1' OR General Contractor (Co. Name) OR Owner OR Window Distributor COPY TO: Building Department < HERS Provider (if applicable) Building Owner at Occupancy EnergyPro 2.1 By EnergySoftUser Number: 2366 Job Number: 00026GH Pane,15 of 21 I INSTALLATION CERTIFICATE (Part 3 of 7) . CF -6R Site Address Permit Number .DUCT DIAGNOSTICS This buiding obtained compliance credit for: ❑ Duct sealing Duct Area Reduction ❑ ACCA Manual D design and installation j, CREDIT FOR REDUCED DUCT SURFACE' ACCA Design AREA OR LOCATION Duct Location' Exterior Measured❑ Duct Design on Plans Surface Area Exterior Surface (CF -1 R) Area ❑ Installed duct diameters match plans ❑ Attic ❑ Crawlspace ❑ Basement ❑ Other Total ❑ TXV installed ❑ Access to TXV valve (if installed) ❑ No TXV, Fan air flow (CFM) ❑ Duct Leakage Measured ❑ Measured leakage (CFM) - HVAC fan air flow (CFM) (measured or calculated as 'Ignore ducts in conditioned space.CF � ' ❑ M = 0.7 x A floor' for CZ 8 through 15 Only a check is ❑CFM = 0.5 x A floor for CZ 1 through 7 & 16 required for location or, it the equipment size is known, the larger of 1 or 2. credit. 1. ❑ CFM =.400 x Cooling Capacity in Tons or 2. ❑CFM = 21.7 x Heating Capacity in Thousands of Btu per hour) Leakage divided by HVAC Fan air flow (must be =< 0.06) For AEROSOL TYPE SEALANTS ONLY:,- The following diagnostic testing was completed: ❑ Duct Fan Pressurization,at rough - in measured leakage CFM CHECK AFTER FINISHING WALL: ' ❑ Pressure Pan Test `❑ House pressuezation test ❑ Visual Inspection of Duct Connections Provide Follow-up Test Results or Inspection Results on a Separate Page ❑ This certifies that the ducts surface area and duct locations were verified. When compliance credit is claimed for duct surface area reducitons and duct location improvements beyond those covered by default assumptions, builder employees or subcontractors shall certify that they have verified that the duct surface area and locations match those on the plans and shall indicate the duct surface area in each duct location on the CF6R. " ❑This is to certify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for compliance credit. (The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees or subcontractors certifying that diagnostic testing and installation meet.the requirements for compliance credit.] Tests Signature, Date Installing Subcontractor Co. Name) Performed OR General Contractor (Co. Name) OR Owner COPY TO: Building Department HERS Provider (if'applicable) - Building Owner at Occupancy ':EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number. 00028GH Page: 16 of 21 i INSTALLATION CERTIFICATE (Part 4 of 7) CF -6R Site Address Permit Number, BUILDING ENVELOPE LEAKAGE DIAGNOSTICS Phis buiding obtained compliance crediffor. ❑ Envelope sealing using diagnostic testing (CF -1R) Needed for Compliance , Measured Blowerdoor Test (from CF -1 R) Results -Building Envelope Leakage (CFM @ 50 Pa) -Leakage level equivalent to an SLA of 3.0 from CF -1 R Minimum Building Leakage equivalent to an SLA of 1.5 from CF -1 R (CFM @ 50 Pa) ❑ Yes ❑ No Is design infiltration less than the SLA 3.0 equivalant (from CF -1 R)? ❑ Yes ❑ No Is mechanical ventilation installed? (Required if design is less than 3.0 SLA) { ❑ Yes. ❑ No Is measured leakage (without fans operating) less than minimum in the above Table (1.5 SLA from CF -1 R)? ❑ Yes ❑ No Is mechanical supply ventilation installed to assure house pressure does not go below minus 5 Pascal relative to outside ambient with all exhaust fans operating? Mechanical Ventilation - Fill in Table if mechanical ventilation is installed Used for Compliance Measured (from CF -1 R) Actual -Continuous Mechanical Ventilation (CFM)t, -Continuous Mechanical Supply Ventilation (CFM) Required to maintain -5 Pa if building.. , envelope leakage is less than minimum (see ; above) -Total Power Consumption of Continuous Mechanical Ventilation (Watts) z ' ❑ This certifies that the building leakage was verified. When compliance credit is claimed for building leakage reduction below default assumptions, builder employees or subcontractors shall certify that they have verified that the building leakage level matches that used for compliance on the CF -6R and shall document the infiltration levels required for compliance and the tested infiltration values on the CF -6R.. ❑ This is to certify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for compliance credit. (The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.] Tests Signature, Date Installing Subcontractor (Co. Name) Performed OR General Contractor (Co. Name) OR Owner COPY TO: Building Department _ - HERS Provider (if applicable) Building Owner at Occupancy ' 1. When mechanical ventilation is required, CFM less than 0.047 CFM per square foot of condttloned floor area indicates failure to achieve compliance 2. As determined from label on fan or manufacturers literature. ;EnergyPro 2.1 By EnergySoft User Number. 2366 Job Number: 00028GH Page: 17 of 21 INSTALLATION CERTIFICATE (Part 5 of 7) CF-61IR Site Address Permit Number The following is an explanation of many of the input values required on this form: HVAC SYSTEMS , Heating Equipment Type must be one of the following: Furnace: Gas(including Liquefied Petroleum Gases or oil -fired central furnace & space heater Boiler: I Gas or oil -fired boiler Pck HeatPum : Packaged central heat pump S IitHeatPum : Split central heat pump RoomHeatPum :I Room heat pump Lr Pk HeatPum : Large packaged heat pump (>=65,000 Btu/hr output) Electric: Electric resistance heating (fixed HSPF = 3.413); radiant electric resistance fixed HSPF = 3.55 CombinedHydro: I Reference water heater under water heating systems below -CEC Certified Manufacturer Make & Model Number from applicable Commission approved appliance directory. -V of Identical Systems" is for those systems with the same efficiency, duct location, duct R -Value and capacity. -Efficiency from applicable Commission certified appliance directory. -Duct Location is attic, crawl space, CVC crawl space, conditioned space, unconditioned space or none. -Duct (or Piping) R -Value from Directory of Certified Insulation Materials and/or manufacturer's data. -Heating/Cooling Load refer to Commission approved load calculation procedure. -Heating/Cooling Equipment Capacity from the applicable Commission certified appliance directory. Note: location elevations over 2,000 ft above sea level require a derating.of output capacity (refer to manufacturer's literature). Cooling Equipment Type must be one of the following: S IitNrCond: Split system air conditioner Pck rCond: Packa ed air conditioner S litHeatPum : I Split system heat pump Pck HeatPum : Packaged heat pump RoomHeatPum : Room heat pump LrgPkgHeatPump: Large packaged heat pump (>=65,000 Btu/hr output). Substitute EER for SEER when SEER is not available. RoomAirCond: Room air conditioner. Minimum SEER varies' LrgPkgAirCond: I Large packaged air conditioner (>=65,000 Btu/hr output). Substitute EER for SEER when SEER is not available. EvapDirect: Direct evaporative cooling system. For compliance calculation purposes, fixed values: SEER = 11.0; duct location = attic; duct insulation R -value = 4.2 Evapindirect: Indirect evaporative cooling system. For compliance calculation purposes, foxed values: SEER = 13.0; duct location = attic; duct insulation R -value = 4.2 i 'Refer. to California Energy Commission (CEC) publication Appliance Efficiency Regulations, P400-92-029 !EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: OW28GH Page: 18 of 21 INSTALLATION CERTIFICATE (Part 6 of 7) CF-61rx Site Address Permit Number The following is an explanation of many of the input values required on this form: , WATER HEATING SYSTEMS Distribution Systems`..Refer to Residential Manual for more details. Standard: I Standard - Supply prssure based s tem no pumps . Pipe Insulation: Pipe Insulation on all 3/4 -inch pipes POU/HWR: Point of Use/Hot Water Recovery System • Recirc/NoControl: I Recirculation loop with no controls Recirc/Timer: Recirculation loop with a timer Recirc/Tem : Recirculation loop with temperature control Recirc/Time + Temp: I Recirculation loop with a timer and temperature control Recirc/Demand:.: Recirculation loop with demand control Water Heater Type Windows, sliding glass doors, french doors, skylights, garden windows, and Information Needed any door with more than one square foot of glass Operator Type; Energy Factor Recovery Efficiency Standby Loss Rated Input Storage Gas, Oil or Electric Yes No No No Heat Pump Yes No No No Instantaneous Gas No Yes " No No Instantaneous Electric Yes No No' No Large Storage Gas No Yes Yes Yes Indirect Gas (Boiler) pNo, Yes (AFUE) No Yes FENESTRATION / GLAZING Fenestration: Windows, sliding glass doors, french doors, skylights, garden windows, and any door with more than one square foot of glass Operator Type; Slider; hinged, fixed. U -Value: Installed U -Value must be less than or equal to value from CF -1 R OR Installed weighted average U -Value for the total fenestration area is less than or equal to value from CF -1 R SHGC: Installed SHGC must be less than or equal to value from CF -1 R OR Installed SHGC for the total fenestration area is less than or. equal to value from CF -1 R OR 'An interior shading device, overhang, or exterior shading device is installed consistent with the CF -1 R Shading Device: Include when the building complied using an interior shading device: blinds, " opaque roller shades, blinds (do not list draperies), an exterior shading device: woven sunscreen, louvered sunscreen, low sun angle sunscreen, roll -down awning, roll -down blinds or slats (do not list bug screen), or an overhang (include depth in feet) INSTALLATION CERTIFICATE Part 7 of 7) CF -6R Site Address Permit Number The following is an explanation of many.of the input values required on the Diagnostic portion of this form (page 3 of 6): TYPE OF CREDIT Refer to Residential Manual Chapters 4 and 5 for more details: Reduced Duct Surface Area: Calculated as the outside area of the duct. Areas must be measured and verified by HERS rater. Improved Duct Location: Supply duct located in other than attic, as verified by location of registers (does not require HERS rater verification). Catastrophic Leakage: Pressure pan test reading must be less than 1.5 Pascal at a house pressure of 25 Pascal. TXV: Access cover required to facilitate verification. Infiltration Reduction: Infiltration is measured without mechanical ventilation operating. Mechanical ventilation is required for very tight house construction when credits for infiltration reduction using diagnostic testing are beng used for achieving compliance. These very tight houses are defined as those with SLA of less than 1.5. The compliance documentation (CF -1 R) will contain the measured CFM target value from a blower door test at 50 Pascal pressure difference that represents this SLA of 1.5. Mechanical ventilation is also required if the builder chooses to design the building to use mechanical ventilation and claims a credit for infiltration below an SLA of 3.0.' The compliance; documentation (CF -1 R) will contain the measured CFM target value that represents this 3.0 SLA. If the builder claims credit in a design for infiltration reduciton that is at an SLA of 3.0 or higher, and the actual measured SLA is 1.5 or greater, then mechanical ventilation is not required. If the SLA in this case were below 1.5, then mitigation (such as mechanical ventilation) would be required. EnergyPro 2.1 By EnergySoft User Number: 2366 Job Number: 00028GH Page:20 of 21 t iHVAC SYSTEM HEATING AND COOLING LOADS SUMMARY (PROJECT NAME DATE MONTANA GUEST HOUSE 3 1030 Sq Ft I 5/4/00 SYSTEM NAME FLOOR AREA Furn-A/C-1 A & 1 B 1,030 [ENGINEERING CHECKS 11SYSTEM LOAD (Number of Systems 1 21 Heating System Output per System 1 36,0001 Total Output (Btuh) ( 72,000 Output (Btuh/sgft) 69.9 Cooling System Output per System 1 19,000 Total Output (Btuh) 38,000 Total Output (Tons) 3.2 Total Output (Btuh/sgft) 1 36.g Total Output (sgft/Ton) 325.3 Air System CFM per System 6D0 Airflow (cfm) 1,200 Airflow (cfm/sgft) 1.17 Airflow (cfm/Ton) 378.9 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions JEATING SYSTEM PSYCHROMETRICS 26.00F 69.2 OF Outside Air 0 cfm 69.2 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM ISensiblel Latent I CFM I Sensible 1 67� 16,6681 3911 1 561 21,043 01 8331 01 0 0 833 01 1 1 1,052 0 0 0 1,052 18, 391 1 23147 LEN UHG2X-45/ 10ACB18 30,136 1,437 72,000 Total Adjusted System Output 30138 1437 72000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 m Jan 12 am 105.0 °F Heating Coil at Time US Supply Fan 1200 cfm 105.0 of Supply Air Ducts . 104.2 of ROOMS 70.0 c F k Return Air Ducts `S 115.0/73.30F 78.6/61.80F M 55.0/53.0°F 55.0/53.0OF _7F Supply Air Ducts Supply Fan 55.6 / 53.3 of 1200 cfm 38.9% R.H. ROOMS 78.0 161.6 OF Outside Air- ' 0 cfm Cooling Coil 78.6/61.8 0 F Retum Air Ducts I EnergyPro 2.1 By EnergySofl User Number. 2366 Job Number: 00028GH Page•21 of 21 1