04-6771 (SFD)BUILDING & SAFETY DEPARTMENT
P.O ox 1504
(760),777-7012
94 5 CALLE TAMPICO
�o� FAX (760) 777-7011
pQR �P'yUINTA; CAL'IFOR'NIA 92253. INSPECTION REQUESTS (760) 777-7153
BUILDING PERMIT
pplication Number04-00 6 1 —Y-� Date' 4/21/05
Property Address:"; 53443 VIA MALLOR"CA
APN: 772 -420 -999 -46 -298943 -
Application description . DWELLING - SINGLE FAMILY DETACHED
Property Zoning*. LOW DENSITY RESIDENTIAL
Application valuation y,, 43,9794
Owner Contractor
- -- — -. i •...a— — = -.••,✓ —.-4`..L — —!_. �' d1y4.+_G1 3. — — — — — — — Y--"— — — — —
DAVID JACOBSEN ,MONARCH HOMES, INC.
73 -290 -EL PASEO #4 73290 EL PASEO, SUITE.#4
.PALM DESERT, CA 92260 PALM DESERT, CA 92260
, (760.) 568-3905
WCC: STATE FUND
WC: 0002290026122 06/01/05
CSLB: 809688 06/30/06
CCC: B
Other struct info ## BEDROOMS 4.00
GARAGE SQ FTG 708.'00
PATIO SQ FTG 773.00
NUMBER OF UNITS 1.00
IST FLOOR SQUARE FOOTAGE 5144.00
P.O. Box 1504 4 4Q����
75-495 CALLS TAMPICO VOCE (760) 777-.7012
FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 FAX
(760) 777-7153
BUILDING & SAFETY DEPARTMENT
V, ,
Application Number: o41—G771 ` ' Date: 0.5,
Applicant: Archjt t or En LI r
Applicant's Mailing Address: Archi e t or En Ineer's Address: r `I
!mac o,�TFU Tei �� • % 3/D �
Lic. No.: G 7-2 3 9
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
ode, and Licensp�s in full force and effect. n� � n�
Licens�e/Class ss_ �j /,� icense No. js a
ate 7 ' Z(I• Oy ontrwo,016AIACC.i ICZ049rT *i 7- 61sl. 1,✓G
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that 1 am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
U 1 am exempt under Sec. , BA P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
�I have and will maintain workers' compens on insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. M�worrker�' compensati�sura'nce carrier and of1j y number are -
Carrier STtl.�i>c wJ / policy Number 2'� y� D 2Lo i2
_ I certify that, in the performance of the work for which this pe it is issued, I shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with those p visions.
ateT ' •"Y' �� plicant
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name
Lenders Address
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this cou to enter up n the above-mentioned property for inspection purposes.
ate' �• 10 Signature (Applicant or Agent): I
--------------------------
�' Application Number
----------------------------------------------------------------------------
----------------------------------------
04-00006771
-----------
Permit
BUILDING PERMIT
Additional desc.
Permit Fee
1693.00
Plan Check Fee
1100.45
Issue Date . .
.
Valuation
400718
Expiration Date
10/18/05
Qty Unit
Charge
-Per
Extension
BASE
FEE
639.50
301.00
3.5000
THOU BLDG
1001001-500,000
1053.50
Permit . . I.
. .
ELEC-NEW RESIDENTIAL
Additional desc
Permit Fee . .
224.20
Plan Check Fee
56.05
Issue Date
'Valuation . . . .
0
Expiration Date-.
10/18/05
Qty Unit
Charge
Per
Extension
BASE
FEE
15.00
5144.00
.0350
ELEC
NEW RES - 1 OR 2 FAMILY -
180.04
708.00
.0200
ELEC
GARAGE OR NON-RESIDENTIAL'
14.16
1.00 15..0000
EA ELEC
TEMPORARY POWER POLE
15.00
Permit . . .
. .
GRADING PERMIT
Additional desc
,
Permit Fee
15.00
Plan Check'Fee
.00
Issue Date . .Valuation
. . . .
0
t' Expiration Date
10/18/05
Qty Unit
Charge
Per
Extension
----------------------------------------------------------------------------
BASE
FEE.,
15.00
Permit . .
.
MECHANICAL..
Additional desc
Permit Fee
101.50
Plan Check Fee
25.38
Issue Date
Valuation . . . .
0
Expiration Date
10/18/05,
Qty Unit
Charge
Per
Extension
BASE
FEE
15.00
3.00
9.0000
EA MECH
FURNACE <=100K
27.00
3.00
9.0000
EA MECH
B/C`<=3HP/100K BTU
27.00
4.00
6.5000
EA MECH
VENT FAN
26.00
1.00
6.5000
.EA MECH
EXHAUST HOOD-
6.50
Permit . .
PLUMBING
Additional desc
Permit Fee
210.00
Plan Check Fee
52.50
Issue Date
Valuation . . . .
0
Expiration Date
10/18/05
Qty Unit
Charge
Per
Extension
BASE
FEE
15.00
23.00
6.0000
-EA PLB
FIXTURE
138.00
1.00 15.°0000
EA PLB_BUILDING
SEWER
15.00
1.00
7.5000
EA `' PLB,WATER HEATER/VENT
7.50
-----------------
.s
Application
---------------------------------------------
Number, . . 04-00006771
--------------
----------------------------------------------------------------------------
Permit . .
. . . PLUMBING
Qty Unit.Charge Per
Extension
1.00
3.0000 EA PLB•WATER INST/ALT/REP
3.00
1.00
9:0000 EA PLB LAWN SPRINKLER SYSTEM
9.00
10.00
.7500 EA PLB GAS PIPE >=5
7.50
1.00
15.'0000 EA PLB GAS METER
15.00
Special Notes
andComments
5144 SQ. FT.
SFD THIS PERMIT DOES NOT I
NCLUDE POOL
& SPA BLOCK WALLS OR
DRIVEWAY APPROACH.April
21, 2005
• 6:24:41 AM
jjohnson
----------------------------------------------------------------------------
Other Fees
ART IN PUBLIC PLACES -RES
599.48
DIF COMMUNITY CENTERS -RES
97.00
DIF CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE
110.05
DIF FIRE PROTECTION -RES
97.00
" GRADING PLAN CHECK FEE
00
DIF LIBRARIES -, RES
225.00
DIF PARK MAINT FAC - RES
5.00
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI) - RES
43.97
DIF STREET MATNT FAC -RES
15.00
DIF' TRANSPORTATION - RES
1098.00
Fee summary
- Charged Paid_ Credited
Due
Permit Fee
------------
Total, 2243.70 _ .00 .00
2243.70
Plan Check
Total 1234.38 500.00 .00
734.38
Other Fee Total
3158.50 .00' .00
3158.50
Grand Total
6636.58 500.00 .00
6136.58
PC
= 7
P.O. BOX 1504 APPLICATION ONLY
Bullding 78-495 CALLE TAMPICO I e�
AfIrirPQR LA QUINTA, CALIFORNIA 92253 (�Ul� 46 a -Z, -`7 411 -w
E?__ _b_.r_or3S45-,d
Mailing -/
Address 7-3-2.-'90
�Q->�u ���� Z����o �%� •���'�®sem
lN:�
Address
State Lic. City
& Classif. ������ Lic. #
Arch., Engr., � J
Designer ®�
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and
effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisionsoI the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes-
sions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon and who does such work himself or through his own employees, provided
that such improvements are not intended or offered for sale. If, however, the building or im-
provement is sold within one year of completion, the owner -builder will have the burden of
proving that he did not build or improve for the purpose of sale).
❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct
the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does
not apply to an owner of property who builds or improves thereon, and who contracts for such
projects with a contractor(s) licensed pursuant to the Contractor's License Law)
❑ 1 am exempt under Sec. B. & P.C. for this reason
WORKER'S COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑ Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less).
I certify that in the performance of the work for which this Permit is issued, I shall not
employany person in any manner so as to become subject to Workers' Compensation Laws of
California.
Date Owner
NOTICE TO APPLICANT If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work
for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
WHITE = BUILDING DEPARTMENT
'� 7--�{.ro — o•Z3
BUILDING: TY CO ST. '7ZOCC. GRP..
A.P. Number
Legal Description Lo % 714 Z9 8`I q — 3
Project Description
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by:
Validated by:
Validation:
Date
YELLOW = APPLICANT PINK = FINANCE
SFt. �j C
Size / r
No. Dw.
SNo.tories
Stories Units
New ❑ Add ❑
Alter ❑ Repair ❑ Demolition ❑
Estimated Valuation
PERMIT
AMOUNT
Plan Chk. Dep.
,—bD
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway EncJffl1r- - W M
Infrastructure ���
_ , A nnnk
A�--
���rMAtt<.�� DEQ
TOTAL
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by:
Validated by:
Validation:
Date
YELLOW = APPLICANT PINK = FINANCE
t
1
1
Coachella Valley Unified School. District.
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DFVF.I.OPF.R FF.F.S PATI)
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMM/IND. AMOUNT:
DATE-
RFCF.IPT-
CHF.r.K H•
INITIALS -
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name Residence is at;The H-ideaway Date: April 26, 2005
Owner's Name: Monarch.Homes Desert Division, Inc. " Phone No. 568-30905
Project Address: 53-443 Via Mallorca La Quinta, CA
Project Description: 1 SFD
APN: 772-410-023
Tract #:
Type of Development: Residential 1 X '
Lot #'s: 46C
Commercial Industrial
Total Square Feet of Building Area: 5,144 sq. ft.
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authored to sign on behalf of the owner/developer.
Dated: April 26, 2005 Signature: .w ��� - 11" zvf ivvr-
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Project Agreement Existing Not Subject to Fee
17620 65995 Approval Prior to 1/1/87 Requirement
. Note:
Number of Sq.Ft. 5,144
Amount per Sq.Ft. $ 2.88
Amount Collected $ 14,814. 72
Building Permit Application Completed: Yes/No
By: Carey M. Carlson, Asst. Supt., Business Services
0
Certificate issued by: Elvira Mattson, Office Technician Sigriature:
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the'amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts. on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject
of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance.
1V:ehnyJocshleclees,'ccrti6cateofcompliance. (i)rm tabiesl7C1 USEi.doc 1/16/03 T
April 22, 2005 ,
Mr. Bob Easton _
1486 East Valley Road t
- Montecito, CA 93108
�tE: J e d t�nal•Workiog Drawings #3
46C on 3 Via Mallorca
- Dear Mr. Easton: i,
-The Hideaway Design Review Committee reviewed the complete Final Working
Drawings submitted for Lot 46C. The project is approved with the exception of
the following corr&nent: '
• Chamaeropg'is not allowed for use in the Transition Area. Please replace
the plant wilth an. acceptable alternate.
A Pre -Construction Meeting has been held 'and construction may commence
once the items listed on the February 24`h letter have been submitted for our
files. Please:call grook,Marshall at (760) 346-1,161 with any questions.
Sincerely,
Hideaway Design Review Committee
cc: lee Winer
DRC Pik
Post -W Fax Note 7671
4 paoa;► '2.
Oate4Fro
Tb Cha
,s
ColDept.
Co.
Phone Ir -
Phone `
Post -W Fax Note 7671
4 paoa;► '2.
Oate4Fro
Tb Cha
�Y
ColDept.
Co.
Phone Ir -
Phone `
Certificate of OccupanY
I vc SL,ro-
OF� Building & Safety Department
This Certificate is issued pursuant to the requirements of Section 109 of the California. Building
Code, certifying that, at the time. of issuance, this structure was in compliance with the
provisions of the Building Code and the various ordinances of the City regulating building
construction and/or use:
BUILDING ADDRESS. 53443 VIA MALLORCA
Use classification: SFD Building Permit 'No.: 04-6771
Occupancy Group: R3U1 Type of Construction: VN Land Use Zone- RL
Owner of Building: DAVID JACOBSEN y Address- 53443 VIA MALLORCA
City, ST ZIP: LA QUINTA CA 92253
By: EDDIE MUIR
Date: 12-1-2006
Building OffiGAI '
POST IN A CONSPICUOUS PLACE
ell, O c— 4Llo G.
CITY OF LA QUINTA
BUILDING & SAFETY DEPARTMENT
FMOF rte° 777-7012
EQUEST LINE-
Lr�� 7 153 i
Owner' )NARCN LIOIVLES SORT DIV, INC
Contra) of ,VI )... T H&fJV.I.E ESERT DI.V, INC #
Permit rnb6fly-
-IT clip
INTA
UOUS PLACE r
INSPECTOR MUST SIGN ALL APPLICABLE SPACES '
-53.443 VIA MI NUORCA
JOB ADDRESS ,
- SQ. -r. SFD THIS PERMIT DOES NOT I �
NCL,UDE. POOL, & SPA Bl,(.)( -.'K WAILS OR r
DRIVEWA V.A-PPROACHRLPLACEMENTJOB CARD.
TYPE OF INSPECTION DATE INSP.
TEMPORARY POWER
SETBACKS
U G PLUMBING / WASTE
U G ELECTRICAL / GROUNDING
OTINGS / STEEL
CONCRETE SLAB ff
DO NOT POUR CONCRETE UNTIL ABOVE SIGNED I`
ROOF NAIL/ PRE -ROI
OKAY TO WRAP .
FRAMING'(COMBINAI
ROUGH ELECTRIC
• ROUGH PLUMBING
INSULATION
COVER NO WORK UNTIL ABOVE SIGNED
INTERIOR GYP. BD. DRYWALL
EXTERIOR LATH
GAS TEST - -
SEPTIC ABANDONMENT.
SEWER CONNECTION "
SEPTIC/ GREASE INTERCEPTOR j
MASONRY INSPECTIONS
FOOTINGS / STEEL
BOND BEAM
I'
POOL / SPA / WATER FEATURE INSPECTIONS
PRE-GUNITE / SETBACKS
U/G PLUMBING
U/G GAS I
U/G ELECTRICAL j
PRE -PLASTER (ALARMS/ BARRIERS
FINAL INSPECTIONS .
TEMP. USE OF PERMANENT POWER -� O
ELECTRICAL
PLUMBING
MECHANICAL l
PUBLIC WORKS DEPARTMENT ( -c, '
COMMUNITY DEVELOPMENT DEPT.
FINAL / JOB COMPLETED.
ABOVE APPROVALS DO NOT INCLUDE RIGHT TO'
,,' TURN ON UTILITIES OR OCCUPY BUILDING
Certificate of Compliance: Residential .(Part 1 of 2) CF -.1 R
Jacobson Residence
0.756
9/1/2004
Project Title
Wood
Date
Lot 46-C - Hideaway La
Quinta
None
0.387
U -Factor
Project Address
Shading
Yes / No
Building Permit #
/ No
Insu-Form Inc.
(760) 324-0216
48.0
0.60
0.45
Bug
Plan Check / Date
Documentation Author
Telephone
0
Front
(East)
Computer Performance
15
0.45
Field check / Date
Screen
Compliance Method (Package or Computer) Climate Zone
Enforcement Agency Use Only
GENERAL INFORMATION
X❑
Front
Total Conditioned Floor Area:.
5,171 f? Average Ceiling
Height: 10.7 ft
Total Conditioned Slab Area:.
4,430 fl? .
Screen
Building Type
y
❑
(check one or more)
'
(South)
X❑ Single Family Detached
❑ Addition `
0.45
❑ Single Family Attached
❑ Existing Building
X❑
❑ Multi -Family
❑ Existing Plus Addition
X❑
Front Orientation: (East) 90 deg
Number of Dwelling Units: 1.00
Number of Stories: 2
Component
Slab On Grade
Slab On Grade
R-19 Wall (W.19.2x6.16)
R-38 Roof (R.38.2x14.16)
Solid Wood Door '
Floor Construction Type: ® Slab Floor
Const.
Frame Assembly
n/a
0.756
n/a
0.756
Wood
0.065
Wood
0.028
None
0.387
❑ Raised Floor
Location/Comments
(attic, garage, typical, etc.)
Covered Slab w/R-0.0 Perimeter Insulation
Exposed Slab w/R-0.0 Perimeter Insulation
Exterior Wall
Exterior Roof
Exterior Door
FENESTRATION Sharlinn novicpc
Type
Orientation
Area
Fenestration
Exterior
Overhang Side Fins
SF
U -Factor
SHGC
Shading
Yes / No
Yes
/ No
Front
(East)
48.0
0.60
0.45
Bug
ScreenX❑
El
F-1
0
Front
(East)
25.0
0.63
0.45
Bug
Screen
X❑
❑
❑
X❑
Front
(East)
105.8
0.55
0.45
Bug
Screen
X❑
❑
❑
X❑
Left
(South)
48.0
0.55
0.45
Bug
Screen
X❑
❑
❑
X❑
Left
(South)
66.0
0.63
0.45
Bug
ScreenX❑
❑
❑
X❑
Left
(South)
130.0
0.60
0.45
Bug
Screen
X❑
❑
❑
X❑
-Rear
(West)
160.0
0.55
0.45
Bug
Screen
X❑
❑
❑
X❑
Rear
(West)
160.0
0.68 '
0.45
Bug
ScreenX❑
❑
❑
a
Right
(North)
48.0
0.55
0.45
Bug
Screen[x]
❑
❑
X❑
Right
(North)
115.4
0.63
0.45
Bug
ScreenX❑
❑
❑
X❑
Left
(Southwest)
25.5
0.63
0.45
Bug
Screen
X❑
❑
❑
X❑
Rear
(West)
5.0
0.63
0.45
Bug
Screen
X❑
❑
❑
X❑
Run Initiation Time: 09/01/04 11:34:30 Run Code: 1094063670
Ener
Pro 3.1 By Ener Soft
User Number: 2655
Job Number:
Pa e:3 of 16
K
M
Certificate of Compliance:
Residential (Part 1 of 2) CF -1 R
Jacobson Residence
` 9/1/2004
Project Title
Date
Lot 46-C - Hideaway La
Quinta
Project Address
Building Permit #
Insu-Form Inc.
(760) 324-0216 Plan Check / Date
Documentation Author
Telephone
Computer Performance
15 Field Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
1-1 1:1
Total Conditioned Floor Area:
' 5,171 if Average Ceiling Height: 10.7 ft
Total Conditioned Slab Area:
4,430 ft2
s Building Type:
❑ ❑
(check one or more)
X❑ Single Family Detached
❑ Addition
❑ Single Family Attached
❑ Existing Building
❑ Multi -Family
❑ Existing Plus Addition
Front Orientation: (East) 90 deg Floor Construction Type: ® Slab Floor
Number of Dwelling Units:
1.00
:Number of Stories:
2 ❑ Raised Floor `
Const.
Component Frame Assembly Location/Comments
Type Type U -Value (attic, garage, typical, etc
Y T.
FENESTRATION
l
Sharlinn navicac
Type . Orientation Area Fenestration Exterior
Overhang Side Fins
SF U -Factor SHGC Shading.
Yes / No
Yes / No
Right (Northeast) 82.6 0.55 0.45 Bug Screen
x❑ ❑
❑ X❑
El 1:1
El El
1-1 1:1
El
1-1 1:1
1:1 El
❑ ❑
❑ ❑
❑ ❑
❑ ❑
_
1:1 1:1
❑❑
❑❑
❑❑
❑ ❑
❑ ❑
❑❑
❑❑
Run Initiation Time: 09/01/04 11:34:30 Run Code: 1094063670
Ener Pro 3.1 By Ener Soft . User Number: 2655 • I Job Number:
Pa e:4 of 16
M
Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
Jacobson Residence 9/1/2004
Project Title Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat Location /
pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments
ParkayPd Heat Pump 7.20 HSPF Ducts in Attic 4.2 'Setback 'First Floor
Packaged Heat Pump 6.60 HSPF Ducts in Attic 49 Setback Second Floor
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments
Packaged Heat Pump 12.0 SEER Ducts in Attic 42 Setback First Flnnr
Packaged Heat Pump A2 0 SEER Ducts in Attic 42 Setback - Sernnrt Flnnr
WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External
Water Heater Water Heater Distribution . # in Input Cap. or Recovery Standby Tank Insul.
System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value
A-0. SMITH FPS -50-224 Small Gas Recirc/Time+Temp_ l_. 43,000 50 0.62 n/a n/a
r J
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: ROK Rasa r., Name: Joan D. Hacker
Title/Firm: 84S F-i9s7*O1V Aj/R 4&4WreL7 Title/Firm: Insu-Form Inc.
Address: '=•r Address: 68255 Corta Road
IAj!�YA- ai4AA A914 Cathedral City, CA 92234
Telephone: BOS' T&tf S Df! Telephone: (760) 324-0216
#: G 2239
3 , os- 1 0 �-
(sign lure) �,0& (date) (sig to ) (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
signature/stamp date
Run Initiation Time: 09/01/04 11:34:30 Run Code" 1094063670
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:S of 16
Certificate of Compliance: Residential ♦ (Addendum) 2F-1 R
Jacobson Residence ; 9/1/2004
Project Title ; J Date
• Special Features and Modeling Assumptions `
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enfnrrement aaenry determines the adeauacv of the iustification. and may refect a building or design that otherwise complies
based on the adequacy of the special justification and documentation'submitted.
+ Plan Field
The HVAC System "Second Floor" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
-
1, •� • � -
HERS Required Verification r' ♦ `
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
10♦— 119— uua.u111c19a u+c ucw vcnn�auUn anu ulaynUmw acauny U1 uioao 111caouMa vn a wnn Lr -um plan Field
t , ... . ° .
t.7 f
Run Initiation Time: 09/01/0411':34:30' Run Code: 1094063670
nergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:6 of 16
U
Mandatory Measures Checklist: ' Residential (Page 1 of 2)' MF -1 R `
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into +
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION. Instructions: Check or initial applicable boxes or enter.N/A if not applicable.
DESIGNER
ENFORCEMENT
Building Envelope Measures
'§150(a): Minimum R-19 ceiling insulation.
y
_.
1150(b): Loose fill insulation manufacturer's labeled R -Value.
Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
'
❑11150(c):
i� not apply to exterior mass walls).
�•
E]' §150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.
+
§150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor,transmission rate no
greater than, 2.0 perm/inch.
§118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage..
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
•
-
§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§150('D: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ,.
§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have: t
a. Closeable metal or glass door'
'
b. Outside air intake with damper and control
c. Flue damper and control
+
2. No continuous burning gas pilots allowed', •.}
Space Conditioning, Water Heating .and Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, show erheads and faucets certified by the Commission.,
y ,
§150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA.
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems:
§1500): Pipe and Tank Insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
'
insulation or R-16 combined internal/external insulation.
-
14. All buried or exposed piping insulated in recirculating sections of hot water systems. '
5. Cooling system piping below 55 degrees F. insulated. ?
6. Piping insulating between heating source and indirect hot water tank.
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:7 of 16
I
+
I
k
Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these, measures regardless of the compliance approach used. Items marked with an
asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
X] '§150(m): Ducts and Fans r '
1. All ducts and.plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, UL181 A, or UL181 B. If mastic or tape is used to seal openings
,
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
e
•
duct tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible; manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of the material.
❑ § 114: Pool and Spa Heating Systems and Equipment J
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance
heating, and no pilot.
2. System is installed with at least 36" of pipe between filte'r and heater for future solar, cover for outdoor pools or
spas.
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas. '
3. Pool system has directional inlets and a circulation pump time switch.
§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)'
§118 (f): Cool Roof material meet specified criteria
Lighting Measures
® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
FX I §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. "
3.1 By EnergySoft User Number: 2655 Job Number: Page:8 of 16
Computer Method Summary .(Part 1 of 3) C -2R
JaCoh-snn Residence
9/1/2004
Date
Project Title
46-('
I
of —Hideaway
Project Address
a_Qlllnta
Building Permit #
Inst i -Form Inc
(760) 324-0216
Documentation Author
Telephone
Plan Check/Date
C'nmptltAr PArformancp
15
Field Check/Date
Compliance Method (Package or Computer)
Climate Zone
Source Energy Use
Standard
.Proposed .
Compliance
(kBtu/sf-yr)
Design
Design
Margin -
Space Heating
2.14
3.09
-0.95
Space Cooling
31.96
31.95
0.01
Domestic Hot Water
5.51
4.57
0.94
Totals
39.61
39.60
0.01
Total Conditioned Floor Area: 5,171 ft2
Building Type: Single Fam Detached
Building Front Orientation: (East) 90 deg
Number of Dwelling Units: 1.00
Number of Stories: 2
BUILDING ZONE INFORMATION
Zone Name • Floor Area Volume
Floor Construction Type: ❑ Raised FloorX❑ Slab Floor
Total Fenestration Area: 19.7%
Total Conditioned Volume:' 55,399 ft 3
Total Conditioned Slab Area: 4,430 ft 2
# of
Units
First Floor 443 487.1 0 a6
_Second Floor 741 666 0 14
Solar
OPAQUE SURFACES Act. Gains
Type Area U -Fac. Azm. Tilt Y / N
Wall 451 0.065 90 gQ ® ❑
Wall . 340 0 065 180 gn ® ❑
Wall 370 0 065 270 gn ® ❑
Wall 570 0.065 0 go ® ❑
Ronf 3,539 0.028 270 0 ® ❑
Wall 290 0 065 90 gn ® ❑
Wall 276 0.065 180 gQ ® ❑
Wall 174 0.065 225 gn ® ❑
Wall 192 n n6s 97n 90 ® ❑
Door 22 0 387 270_ 90_ ® ❑
Wall 266 0.065 o 90
Wall 17 0.065 45 go ® ❑
-Root_ 741 0 028 go 0 ® ❑
❑❑
Thermostat Vent
Zone Type Type Hgt. Area
Cnnditinned Sethark $ n/a
Sleeping _S_leepingStat 8 n/a
Form 3 Reference Location / Comments
0
❑ ❑'
❑❑
❑ ❑
F-1 F-1
❑ ❑
F-1 F-1
❑❑
F1
❑❑
F ❑
❑❑
-1 El
Run Initiation Time: 09/01/04 11:34:30 Run Code: 1094063670
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number. Page:9 of 16
Computer Method Summary (Part 2 of 3) C -2R
Jacobson Residence 9/1/2004
Project Title Date
FENESTRATION SURFACES
Location/
Comments
INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin
# Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt.
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
Second Floor
Second Floor
Second Floor
Second Floor
Second Floor
Second Floor
Second Floor
Right Fin
Dist. Len. Hgt.
1
Bug
Screen
0.76
8.0
U-
2.0
Act.
IGlazing Type
#
Type -
Bug
Screen
Area
Factor
SHGC
Azm.
Tilt
1_
Window
Front
(East)
480
-0 600_
0 45
9f)
qQ Milnard Windows
2
Window
Front
(East)
15.0
0.630
0.45
90
90 Milgard Windows
3
Window
Front
(East)
105.8
0.550
0.45
90
90 Milgard Windows
4
Window
Left
(South)
48.0
0.550
0.45
180
90 Milgard Windows
5
Window
Left
(South)
42.0
0.630
0.45
180
90 Milgard Windows
6
Window
Left
(South)
88.0
0.600
0.45
180
90 Milgard Windows
Z
Window
Left
(South)
12-0
0-600
0.45
180
90 Milgard Windows
8
Window
Left
(South)
30.0
0.600
0.45
180
90 Milgard Windows
6
Window
Rear
est)
80.0
0.550
0-45
270
90 Milgard Windows
1Q
Window
Rear
est)
160.0
0.680
0.45
270
90 Milgard Windows
11
Window
Rear
(West)
80.0
0.550
0.45
270
90 Milciard Windows
12
Window
Right
(North)
48.0
0.550
0.45
0
90 Milgard Windows
1a
Window
Right
(North)
15.0
0.630
O45
0
_90 Milgard Windows
14
Window
Right
(North)
12.4
0.630
0.45
0
90 Milgard Windows
15
Window
Right
(North)
33.0
0.630
0.45
0
90 Milgard Windows
16
Window
Right
(North)
6.2
0.630
0.45
0
90 Milgard Windows
17
Window
Right
(North)
15.0
0.630
0.45
0
90 Milgard Windows
18
Window
Front
(East)
10.0
0.630
0.45
90
90 Milgard Windows
JR
Window
-Left
(South)
8.0
0.630
0.45
180
90 Milgard Windows
20
Window
Left
(South)
16.0
0.630
0.45
180
90 Milgard Windows
21
Window
Left
(Southwest)
25.5
0.630
0.45
225
90 Milgard Windows
22
Window
Rear
(West)
5.0
0.630
0.45
270
90 Milgard Windows
23
Window
Right
(North)
33.8
0.630
0.45
0
90 Milgard Windows
24
Window
Right
(Northeast)
82.6
0.550
0.45
45
90 Milgard Windows
10.4
8.0
0.1
8.0
8.0
Location/
Comments
INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin
# Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt.
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
First Floor
Second Floor
Second Floor
Second Floor
Second Floor
Second Floor
Second Floor
Second Floor
Right Fin
Dist. Len. Hgt.
1
Bug
Screen
0.76
8.0
6.0
2.0
0.1
2.0
2.0
2
Bug
Screen
0.76
5.0
3.0
2.0
0.1
2.0
_
2.0
3
Bug
Screen
0.76
11.5
9.0
7.0
0.1
7.0
7.0
4
Bug
Screen
0.76
8.0
6.0
2.0
0.1
2.0
2.0
5
Bug
Screen
0.76
6.0
7.0
2.0
0.1
2.0
2.0
6
Bug
Screen
0.76
8.0
11.0
2.0 0.1
2.0
_
2.0
7
Bug
Screen
0.76
3.0
2.0
2.0
0.1
2.0
2.0
8
Bug
Screen
0.76
5.0
6.0
2.0
0.1
2.0
2.0
9
Bug
Screen
0.76
8.0
10.0
8.0
0.1
8.0
8.0
10
Bug
Screen
0.76
10.0
16.0
22.0
0.1
22.0
_
22.0
Ti
Bug
Screen
0.76
8.0
10.0
9.0
0.1
9.0
_
9.0
12
Bug
Screen
0.76
8.0
6.0
30.0
0.1
30.0
30.0
13
Bug
Screen
0.76
5.0
3.0
2.0
0.1
2.0
2.0
14
Bug
Screen
0.76
2.8
2.4
2.0
0.1
2.0
2.0
15
Bug
Screen
0.76
5.5
6.0
2.0
0.1
2.0
2.0
16
Bug
Screen
0.76
2.8
2.4
2.0
0.1
2.0
_
2.0
17
Bug
Screen
0.76
5.0
3.0
2.0
0.1
2.0
_
2.0
18
Bug
Screen
0.76
4.0
2.5
2.0
0.1
2.0
2.0
19
Bug
Screen
0.76
4.0
2.0
2.0
0.1
2.0
_
2.0
20
Bug
Screen
0.76
4.0
4.0
2.0
0.1
2.0
2.0
21
Bug
Screen
0.76
4.5
5.8
2.0
0.1
2.0
_
2.0
22
Bug
Screen
0.76
2.5
2.0
2.0
0.1
2.0
2.0
23
Bug
Screen
0.76
4.5
7.5
2.0
0.1
2.0
2.0
24
Bug
Screen
0.76
8.0
10.4
8.0
0.1
8.0
8.0
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paoe:10 of 16 1
Cooling Equipment f Minimum Duct
Type (air conditioner, ' Efficiency Location Duct Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments
Packaged Heat Pump 12.0 SEER Ducts in Attic 4-2— Setback First Floor
Packaged Heat Pump 12.0 SEER Ducts in Attic 4.2 Setback Second Floor
WATER HEATING SYSTEMS Ratedl Tank Energy f=acts 1 Tank Insul.
Water Heater Water Heater Distribution # in Input Cap. 'or Recovery Standby R -Value
System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext.
A.O: SMITH FPS -50-224 Small Gas Recirc/Time+Temp 1X3-000 50 0.62 n/a n/a
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
0
r
Computer Method Summary
(Part 3 of V C -2R
Jacobson Residence
9/1/2004
Project Title
Date
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat
Inside
Location ,
Type (sf) (in.) Cap. Cond. Form 3 Reference
R -Val.
1
Comments
PERIMETER LOSSES
F2 Insulation
Type Length Factor R -Val. Depth Location / Comments
Slab Perimeter 22 '-0-M 0.0 0 First Floor
Slab Perimeter 99 0.76 0-0 —0 First Floor
HVAC SYSTEMS "
Heating Equipment . Minimum Distribution Type
Type (furnace, heat Efficiency and Location Duct
Thermostat
Location /
pump, etc.) (AFUE/HSPFxducts/attic, etc.) R -Value
Type
Comments
Packaged Heat Pump 7.20 HSPF Ducts in Attic 4-2
Setback
First Floor
Packaged Heat Pump 6.60 HSPF Ducts in Attic 4.2
Setback
Second Floor
.Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Cooling Equipment f Minimum Duct
Type (air conditioner, ' Efficiency Location Duct Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments
Packaged Heat Pump 12.0 SEER Ducts in Attic 4-2— Setback First Floor
Packaged Heat Pump 12.0 SEER Ducts in Attic 4.2 Setback Second Floor
WATER HEATING SYSTEMS Ratedl Tank Energy f=acts 1 Tank Insul.
Water Heater Water Heater Distribution # in Input Cap. 'or Recovery Standby R -Value
System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext.
A.O: SMITH FPS -50-224 Small Gas Recirc/Time+Temp 1X3-000 50 0.62 n/a n/a
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
0
Computer Method Summary (Addendum) C -2R
Jacobson Residence .. 9/1/2004
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. I Plan I Field
The HVAC System "Second Floor' must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a fort
HERS
CF -6R. Plan Field
Run Initiation Time: 09/01/04 11:34:30 Run Code: 1094063670
EnergyPro 3.1 By EnergySoft . User Number: 2655 Job Number:
I Page:12 of 16
7
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Jacobson Residence 9/1/2004
SYSTEM NAME FLOOR AREA
First Floor 4,430
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
I I COIL HTG. PEAK
CFM
I Sensible
Latent
I I CFM
I Sensible
4,515
79,195
11,412
2,113
71,755
0
3,960
3,588
0
0
0
0
0
0
0
0
0
3,960
3,588
87,1141 11,4121 F---78,9301
CARRIER 48JZN060115301 113,157 45,548 108,517
10.0 kW Supplemental Electric 102,390
Total Adjusted System Output 113,157 45,548 210,907
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 m Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0 OF 69.4 OF 69.4 OF = 86.3 OF 102.2 OF
Supply Air Ducts
Outside Air
0 cfm Supply Fan Heating Coil Aux. Heat Coil 101.7 OF
6000 cfm ROOMS
69.4 of 70.0 of
Return Air Ducts I
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0/77.4OF 78.6/66.4°F 78.6/66.3OF 61.0/59.9OF
„;'"`' Supply Air Ducts
Outside Air'`
0 cfm Supply Fan Cooling Coil 61.6 / 60.1 OF
6000 cfm 54.0% R.H. ROOMS
78.6/66.40F 78.0/66.2OF
h Return Air Ducts `i
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:13 of 16
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Jacobson Residence 9/1/2004
SYSTEM NAME FLOOR AREA
Second Floor 741
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
I Sensible
563
12,385
345
231
9,535
0
619
477
0
0
a
0
0
0
0
0
0
6191
1 477
13,6241 345 10 489
HVAC EQUIPMENT SELECTION
CARRIER 48GXN02406031 18,055 2,815 15,521
5.0 kW Supplemental Electric 17,065
Total Adjusted System Output 18,055 2,815 32,586
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 m Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0°F 69.4°F 69.4°F 88.3°F 109.2°F
' 00 Supply Air Ducts
Outside Air
0 cfm Supply Fan Heating Coil Aux. Heat Coil 108.6 °F
765 cfm ROOMS
70.0 OF
69.4 °F
k Return Air Ducts 4
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0/77.4°F 78.8/63.4°F 78.8/63.30F 56.7/55.40F
' '' Supply Air Ducts
Outside Air w
0 cfm Supply Fan Cooling Coil 57.5 / 55.7 OF
765 cfm 44.1 ,6 R. H. ROOMS
78.8/63.4°F 78.0/63.2°F
>% Return Air Ducts y
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 14 of 16
e%f%RA 1 f% A r% C% 1 MARA A rlV
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number.
Page: 15 of 16
ROOM LOAD SUMMARY
PROJECT NAME
Jacobson Residence
DATE
9/1/2004'
SYSTEM NAME
Second Floor
FLOOR AREA
741
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
NT
LATENT
CFM
SENSIBLE
Second Floor
Second Floor
1
563
12,385
345
563
12,385
345
231
9,535
4
PAGE TOTAL
TOTAL
1 5631
12,3851
3451
2311
97535]
5631
12,3851 7345
1 2311
9,535
EnergyPro 3.1 By EnergySoft User Number: 2655 -Job Number: Page:16.of 167
WEDDL,E
SURVEYING MAPPING, INC
Boundary- Construction • Topographic Aerial Surveys • ALTA Surveys • GPS Consulting
June 9, 2005
- Mr. TimothyR. Jonasson
Public Works Director./ City Engineer
-City of La Quinta
78=495 Calle Tampico
La Quinta,=CA 92253=1504
Re:' Pad/Form Grade, Verification. _
City -of La Quinta
Lot 46C Tract_No.' 29894-3 Amended
TBE --HIDEAWAY
Dear Mr. Jonasson: _
-We have performed a field'survey to determine the vertical. location: of the building pad
and -form for the above referenced project, The elevation's observed are as follows:
PAD (DESIGN) PAD. (AS -BUILT)'
998.40 , 998.4
FORM (DESIGN) _ FORM (AS -BUILT) _.
998.90: 998.87
These field observations, are in substantial- .conformance with the _precise-giading plan _ .
. - _�..-
prepared 'by-ESSI-SHAHANDEH, CIVIL ENGINEER; dated' 3/3/04 -and the building
horizontal location substantially conforms ,to the. required setbacks and site layout as
shown on the approved site plan.
Sincerely;
WEDDLE. SURVEYING MAPPING, INC. 5�� 1.ANp s(�
O
- * NO: -5570 m "X
David L. Weddle; President' EXP 09/30/05
L.S. 5570, Exp 9/30/05 s-
P.O. Bax 10418 • Palm Desert, CA 92255-0418
73.-960 Hwy. 111, Ste. 6 • Palm Desert, CA. 92260 • 760.346.3748
E-Mail:'WedSury @061.com • Fax 760.346.3749' '`
Gary
EW SHAHANDkH. C1111L ENGINEER
45175 Panorama Dr., Suite "E" Telephone (760) 340-5597 '
Palm Desert, CA. 92260 ; Fax (760) 340-1121
w t � January 24`x, 2006 .. ♦_, � .
r
City of La Quinta
Department of Building & Safety
RE: 3-443 ViaRfiorQ La Quinta, CA
C_Lot 46C Hideaway, Matt Cwiertnia Residence
To..Whom It May Concern:, *'
This letter is to verify specifically that the minimum required anchor bolts and hold
downs for both the shear panel and double wall between the garage doors on the'above
mentioned structure have been installed satsifactorily by the contractor. This portion•and
the rest of the structure have been inspected and observed to be in conformance with the
-approved plans..
Sincerely,
Essi Shahandeh, P.E. jQ4G V�p,F SHq 9 FZ
4,a yy
4 Q m
w NO. X783
`r_ 'Exp.
4F OF CAI���
ESSI SIIAII DSII, (MMIC FjV6bVEER
45175 Panorama Dr., Suite "E" ,Telephone (760) 340-5597
Palm Desert, CA 92260
Fox(760)340 1121
January 13, 2006
'City of La•Quinta - 1
78-495 Calle Tampico
La Quinta, CA. 92253.
APveperformed
uilding Inspector
lrca, Matt Cwiertnia Residence
way . • .
a Framing Ispectibn on this project and found it to be in
compliance with the approved permitted plans, I have also reviewed and approved all
differences between the plans and as -built. '
Sincerely,
Essi Shahandeh, P.E. ; ,
r
.. Q�,®FESS10A,,
CD
LU w No.47834"
c1c: Ems, /2 �/ 7
• Sr \
• v ^ t gTEOF