Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
06-3497 (SFD)
a - y P.O. BOX 1504 _ VOICE (760) 777-7012 78-495 CALLE TAMPICO ; FAX (760) 777-7011 h , LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT ' F• „r :` . Date: - 6/05/07 Application Number: 667-970-0 03-4 9Z Owner: ' Property, Address: 53347 VIA MALLORCA RON & SUE MOBLEY APN: 772-420-999-43 .-298943= 305 S GENIUS % Application description: DWELLING': SINGLE FAMILY DETACHED ' PAYSON, AZ 85541 , - Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: '407056 Contractor: ; Applicant`. - ,, Architect or Engineer CF3 LUXURY HOMES INC,r "�� < •; ` 122 - N 2ND QST, ,A-404' N 4. t',, ° i' yI"s PHOENIX, AR 85004 : �� (602)377-5102 _ �'.,C/ryO #LIC No OOR SQUARE FOOT1 LIC. NO.: 874172AN— ,., < ,,• rt r � , t- ' ^� s. a ..Y' >.. - P 4."q -'I - -r - - = - - - - - - - - - - - - - - 1 - - - - - - - - - - - - - - - - - - - - - - - - - ---_ - - - - - - ,2 #'• r LICENSED CONTRACTOR'S DECLARATION t ' r - +• . -• i ' '�% Y ,t s z , -�.' •. a ,_ .� WORKER'S COMPENSATION DECLARATION Thereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with _ _ I herebyaffirm under penalty of perjury one of•thefollowing declarations: _ ,� •" ;,.�� -..,?- Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect •' ; ` -" •'• ` I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided •+ -1, + 4_t,! • a License Class: B - License'No.: .874172 _ - s. - "for'by Section 3700 of the Labor Code, for the performance of the work for which this permit is - •�'r e. ��CC1 4. ..---•--_ - n, y p c issued. .e„S .•- - . Date { V ,`—Contract i ,-', v • f l have and will maintain workers' compensation insurance, as required by Section 3700 of the labor - . • • 1 • ' ^rte yr't *• Code, for the performance of the work for which this permit is issued.' My workers' compensation OWNER -BUILDER DECLAR ION - - ,r'-, , • r '4 "y - - • insurance carrier and policy number are: •,n ' - 4: 1. y_, •`Y:f I•hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the ''r ;Carrier ST. 'PAUL TRAVEL . Policy Number-.. 17859010. a. r following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to, , }- 4 r, ._•:-'�': _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any s ' ` T• �,r construct, alter, improve, demolish; or repair any structure; prior to its issuance, also requires the applicant for the ` t.; a R , - person in any manner so as to become subject to the workers' compensation laws of California,, a 1y ,;�.� •+. permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State w h'`� e ` _ '= r and agree that, if I should become subject to the workers' compensation provisions of Section i V License taw (Chapter 9 (commencing with Section 7000) of Division 3 of the, Business and Professions Code) or” t ;.� �. 4` 700-af.the Labo Code,1 she)fort ith complywith th 'sions. •; - `'� t,+s - I: '� that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 byf,�� '^� - �w•r. + v �� any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 155001.: i r}^ Dat`S�TAPPIicant7l ti+ I 1 -1, as owner of the property; or my employees with wages as their sole compensation, will do the work, and a �` `- t✓ - '�':•� _ 1 — - - - n the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors'. State License Law does not apply to an owner of property who builds or improves thereon,' + �. ; SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and -who does the work himself or herself through his or her own employees provided that the ; ` -DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN• �,�-+• improvements are not intended or offered for sale. If, however, the building or improvement is sold within , SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. - _ +�4 "• r� one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ' - - f - 1 - ' APPLICANT ACKNOWLEDGEMENT ,T'•,, _ ' i, (• I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. '_IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the - i1 ' - - 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of- - conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractors) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for t_ a - pursuant to the Contractors' State License Law.). , whose benefit work is performed under or pursuant to any permit issued as a result of this application, - ,.. (_) 'I am exempt under Sec.-, B.&P.C: for this reason - - the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City ' - - •� - - r•' - - of La Quinta, its officers, agents and employees for any act or omission related to the work being - + - '• - - r performed under or following issuance of this permit. - Date: - - Owner. , _ 2. Any permit issued as a result of this application becomes null and void if work is not commenced _ • " - - -- - - - within 180 days from date of issuance of such permit, or, cessation of work for 180 days will subject, • CONSTRUCTION LENDING AGENCY , - permit to cancellation. • , .I hereby affirm under penalty`of,perjury that there is a construction lending agency for the performance of the • - I certify that I have read this application and state that the above information is correct. I agree to comply with all ' - work for which this permit is issued ISec. 3097, Civ. C.). city and county ordinances and state laws relating to building cons ruction, and hereby authorize representatives • _ _ of this ounty. enter. upon the above-mentioned pr erty-for ins ctio urposes. - -• Lender's Name: -- _ - • - • - DatSignature (Applicant or Agi"'- f Lender's Address: : - - - LQPER111T A? Application Number 06-00003497 Permit . . BUILDING PERMIT Additional desc Permit Fee . . . 1.556.50 Plan Check Fee 1011.73 Issue Date Valuation 361144 Expiration Date 12/02/07 Qty Unit Charge Per. Extension BASE FEE 639.50 262.00 3.5000 THOU BLDG 100,001-500,000 917.00 Permit ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . 210.34 Plan Check Fee 52.59 Issue Date Valuation 0 Expiration Date 12/02/07 Qty Unit Charge Per Extension BASE FEE 15.00 4636'.00 .035.0 ELEC NEW RES = 1.OR..2 FAMILY 162.26, " 904.:00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 18.08 1.00 15.0000 EA" ELEC TEMPORARY POWER POLE 15.00 Permit GRADING PERMIT Additional.d.esc - Permit Fee .:. 15:00 Plan Check "Fee 1.00 Issue Date Valuation 0 . Expiration Date 12/02/07, Qty Unit 'Charge Per.. Extension BASE FEE 15.00 Permit, MECHANICAL Additional' desc Permit Fee 194.50 Plan Check•Fee 48..63 Issue Date -Valuation 0- Expiration Date 12/02/07 Qty Unit Charge Per Extension BASE FEE 15.00•= 6.00 9.0000 EA MECH FURNACE <=100K 54.00 6.00• 9.0000 EA MECH B/C <=3HP/100K BTU - 54.00. 10.00 6.5000 EA' MECH VENT FAN 65.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 LQPERMIT i� Application Number . . .. •06-00003497 Permit PLUMBING Additional desc . Permit Fee . . . . 222.00 Plan Check Fee •55.50 Issue Date . . . . Valuation . . . . 0 Expiration Date 12/02/07 Qty Unit Charge. Per Extension BASE FEE 15.00 22.00 6.0000,EA PLB FIXTURE 132.00 1:00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 6.0000 EA PLB ROOF DRAIN 6.00 2.00 7.5000 EA' PLB WATER HEATER/VENT 15.00 1'.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB•LAWN SPRINKLER SYSTEM 9.00. 16..00 .7500 EA PLB GAS PIPE >=5 .12.00 1.00 15.0000 EA PLB GAS 'METER 15.00 Special Notes.and Comments - 4636 SQ. FT. SFD.-THIS PERMIT DOES NOT INCLUDE POOL &.SPA BLOCK WALLS OR DRIVEWAY APPROACH.June 1, 2007 8:34:44 -AM JJohnson ------=-=---------- ----------------------------- Other.Fees ; ----------------- ART IN PUBLIC PLACES -RES 517.64 " DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER- RES 995.00 ENERGY REVIEW FEE 101.17 DIF,FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE 15..00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC -_RES 22.00 . DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 40.70 DIF STREET MAINT FAC -RES'. 67.00 DI.F TRANSPORTATION -•RES 1930:00 Fee summary Charged' Paid Credited ---------- Due'. Permit Fee Total -- ------- - 2.198.34 00_ .00 -------- 2198.34. Plan Check Total 1168.45 750-:00 .00 418.45 Other Fee Total 5149.51. .00 .00 5149.51 Grand Total 8516.30 750.00, .00 7766.30 LQPERIMIT - P.O. BOX 1504 APPLICATION ONLY `Building 78-495 CALLE TAMPICO `Address �- ��� v ` °e ALA QUINTA, CALIFORNIA 92253 er\tjg N 4 BUILDING: TYPE CONST. OCC. GRP. Mailing 2�- Address G —N\ L�L.� A.P. Number_ _7%�1 � � L� 1�-- SR City so �ZiTel. g p L� 2)s,s� � `qa$ 4�1 - C. ( Legal Description — (' Cont\� Project Description O ;5o Ru k- 3 L-USC®�: ►�-IC�Nl2.S � N� E e Clt ZI I. Sq. Ft. Size ����. No. No. DIN. Stories Units State Lic. & Classif. g 4 `� City Lic. # Arch., Engc, Designer �^L1 [IN h L'l 1Z New'> Add ❑ Alter ❑ Repair ❑ Demolition ❑ Address Tel. City --Q E Zip State gsa1� Lic. # LICENSED CONTRACTOR'S DECLARATION eby affirm that I am licensed under provisions of Chapter 9 (commencing w' Section \70 of Division 3 of the Business and Professions Code, and my license is in I force and e G SIGN A RE DATE R DECLARATION OWNER-BUILleetn Estimated Valuation I her y affirm that I am exempt frome Contractor's License aw for the following reason: (S . 7031.5, Business and Profesns Code.. Any city or c unty which requires a permit to co struct, alter, improve, demolisr repair anystructure, rior to its issuance also requires the plicant for such permit to fileigned statement the a is licensed pursuant to the provisions f the Contractor's License LChapter 9 (comm Ging with Section 7000) of Division 3 of th usiness and Professions e, or that he is ex pt therefrom, and the basis for the alleged a mption. Any violation of Section 7031.5 by an pplicant for a permit subjects the applicant to a ivil penalty of not more tfive hundred Mars ($500). PERMIT AMOUNT Plan Chk. Dep. (� Plan Chk. Bal. ❑ I, as owner of the roperty, or my employwith wages their sole compensation, will do the work, and the str tura is not intended oered for sa . (Sec. 7044, Business and Proles- sions Code: The Cont ctor's License Law s not appl to an owner o/ property who builds or improves thereon an who does such woimself or hrough his own emplo ees, provided that such improvements a not intended offered f sale. If, however, the building or im- provement is sold within a year of compion, th owner -builder will have the burden of proving that he did not buil or improve for purp se o/ sale).❑ I, as owner of the property, m exclusivelyntr ting with licensed contractors to construct project. (Sec. 7044, Busin s and Profeon Code: The Contractor's License Law does not apply to an owner of prope who buildr ' proves thereon, and who contracts for such projects with a contractor(s) lice ed pursuo the Contractor's License Law.) ❑ 1 am exempt under Sec. B.C. for this reason Const. Mech. Electrical Plumbingthe S• M.I. Grading Lr L1 Driveway Enc. Date owner Infrastructure CITY OF LA UINTA WORKER'SCO ENSATION DECLARATION hereby affirm that I have a certate consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certifi d cop thereof. (Sec. 3800, Labor Code.) Policy No. Com any ❑ Copy is filed with the city. Certified c y is hereby furnished. CE IFI TE OF EX PTION FROM WOR ERS'COMPENSA ONINSURANCE TOTAL REMARKS (This section need not be c plated i/ the permit is r one hundred dollars ($100) valuation or less). I certify that in the p ormance of the work for ich this permit is issued, I shall not employ any person in an manner so as to become subje t to Workers' Compensation Laws of California. Date 0 er tion you should become NOTICE TO APPLIC T I/, alter making this Certificate oLar subject to the Wor ars' Compensation Provisions o/ the Code, you must forthwith comply with such ovisions or this permit shall be deemed d. ZONE: BY: . Minimum Setback. Distances: CONSTRUCTION LENDING AGENCY lirm, Front Setback from Center Line that there is a construction lending agency for the part ante of the work ich thI permit is issued. (Sec. 3097, Civil Code.) Rear Setback from Rear Prop.Line r's N a Side Street Setback from Center Line r's dress is s a building permit when properly filled out, signed and validated, and subject to i if work thereunder is suspended for 180 days. Side Setback from Property Line /Ceereby rtity that I have read this application and state that the above information i orrect. a to comply with all city and county ordinances and state laws relating to b 'Iding uction, and hereby authorize representatives of this city to enter the above -men ned y for inspection purposes. FINAL DATE Issued by: INSPECTOR Date Permit ure of applicant Date Address Validated by: tate, Zip Validation: WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE Coachella Valley Unified School District Th;s Box For District Use only t 83-733 Avenue 55, Thermal, CA 92274 DEVELOPER FEES PAID (760) 398-5909 - Fax (760) 398-.1224, AREA: AMOUNT ' LEVEL ONE AMOUNT: •. LEVEL TWO AMOUNT: MITIGATION AMOUNT: .COMM/MD. AMOUNT: . DATE: RECEIPT:. CHECK p: • INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) ' Project Name: Residence_ is at_the-Hideaway, Date: June 26, 2007 Owner's Name: Ron & Sue Mobley Phone No. 602-6844002 Project Address: 53=347 Via. Mallorca La Quinta, CA Project Description:. 1 SFD ` APN: 772-420-999743-298943 Tract #: Lot #'s: Type of Development:. Residential r RX:. , ,. Commercial Industrial Notal Square Feet -of Building Area: 4,636 sq. ft. c Certification of Applicant/Owners: The person signing certifies. that the'above informaton'is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: June 26, 2007 Signature: SCHOOL DISTRICT'S REQUIREMENTS FORTHE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code. .-,,.,Project Agreement Existing Not Subject to Fee .17620 65995 _ ' Approval, Prior to 1/1/87. Requirement Number of Sq.Ft. 4,636 Amount per' Sq.Ft. $3.91 Amount Collected $18,126.76 / Building Permit Application Completed: Yes/No t.. By; Carey M. Carlson; Asst. Supt., Business Services Certificate issued by: Elvira Mattson, Office Technician Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 906day protest period in regard to such' Fees or the validity, thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally; the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificateof Occupancy. 'As in the latter,. the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if building permit has not been issued for the project that is the subject of this Certificate, the owner will -be reimbursed all fees that were paid to. obtain this, Certificate of Compliance. iv1V:c/mydocs/devfees/certificate of compliance form Updated 3=2007 3/9/07 J'un.23 06 04c50p Ron and Sue Mobletj 4808368282 p.l RECORDING REQUESTED BY First American Title Company AND WHEN RECORDED MAIL TO: Ronald W. Mobley and Sue H. Mobley 13771 N. Fountain Bills Blvd #114-3. Fountain Hills, AZ 85268 Ste, 3q 7 ,A ®®C ft 2®®5--®299438 04/15/2e05 Oa:00A Fee:30.00 Page 1 of 2 Doc T Tax Paid Recorded in Official Records County of Riverside t Larry U. Uard Assessor, County Clerk & Recorder M s U PAGE SIZE I QA POOR RCOOR SHF MISO. A R L COPY LONG REFUND ,+OMG E+(A!.7 A.P.N:: 772-410-023-0 File No.: RPD -1788959 (AM)• --\2 GRANT DEE® The Undersigned Grantor(s) Declare(s): DOCUMENTARY TRANSFER TAX $935.00; QTY TRANSFER TAX $0.00; t L/ C x computed on the consideration or full value of property conveyed, OR _ computed on Lh^ considaration or Cul! va ue tens •a c er fk2l.s and/or encumbrances remaining at time of sale, } unincorporated area; -[ x ] City of La Quints, and FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Dennis P. Walters, a single man hereby GRANTS to Ronald W. Mobley and Sue H. Mobley, husband and wife as joint tenants the following described property in the City of La Quinta, County of Riverside, State of California: PARCEL 1: LOT 43 OF CT NO. 29894-3, IN THE CITY OF LA QUINTA, AS SHOWN BY MAP ON FILE IN �6OW3�1 PAGES 35 ( ) THROUGH 48, INCLUSIVE, OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF RIVERSIDE COUNTY, CALIFORNIA. EXCEPTING THEREFROM TO GRANTOR, AND ITS SUCCESSORS AND ASSIGNS, INTEREST IN ALL WATER, MINERALS, OIL, GAS, PETROLEUM, OTHER HYDROCARBON SUBSTANCES AND ALL GEOTHERMAL ENERGY SOURCES IN OR UNDER SAID D LAND OR WHICH MAY BE PRODUCED FROM SAID LAND. PARCEL 2: NON-EXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, DRAINAGE, MAINTENANCE, REPAIRS ®MBD FnR SITHFR PURPOSES, ALL AS DESCRIBED IN THE DECLARATION. Dated: _02118/2005 Dennis P_ Walters 4 Jun .23 0-6 04:50p Ron. and Sue Mobley 4808368282 p.2 A.P.N.: 7727410-023-0 -Grant Deed- continued File No.:RPD-1788959 (AM) Date: 02/18/2005 . STATE OF - . ss. COUNTY OF On before me, personally appeared personally known to me, (or proved to me on the basis of satisfactory evidence) to be the person(s) whose -name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies) and that his/her/their signature(s) on the instrument the person(s) or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my hand and official seal. This area for official notarial seal Signature,b - - TITLE 24 REPORT Title 24 Report for: Zuniga Casit`a? Lot 43, Tract -29894-3 La Quinta, CA Project Designer: Architectural Estates Design Studio 209 E. Ellis Dr. Tempe, AZ 85282 480-683-2077 Report Prepared By: Troy Lindquist - Alternative Energy Systems . 229 N. Central Ave., Suite 500 Glendale, CA 91203 (818) 246-2844 - Job Number:, 0 F LA QUINTA 061664 CITY O pE�T.. APR p 200 BUILDING & SAFE AP P �Ov ION'..,, ON � Date: FOR CONS B� / 4/18/2007 _ DAT L`S The Energ puter program h been used to perform the calculations summarized in this compliance report.. This program has approval and is authorized by the California Enerommission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: 061664 User Number: 2266 7 Certificate Of Compliance: Residential (Part 1 of 4) CF-1 R 2u.niga_Cas.ita 4J_1.8/_2007 Project-Title Date Lot 43, Tr_act298.9A-3-La_Quinta Project Address Building Permit # _Altor_n.ative_Ener_g_y_S_y_stems (818)-246-2844 Plan Check/Date Documentation Author Telephone _Ener_Q(]yyP_r_o -CA-Climate-Zone-1-5 Field Check/Date Complidrice Method Climate Zone TDV Standard Proposed Compliance _kBtu/sf-y r) Design Design Margin Space Heating 1.67 1.34 0.33 Space Cooling 97.36 116.85 -19.49 Fans 13.97 16.63 -2.66 Domestic Hot Water 40.42 18.41 22.01 Pumps 0.00 0.00 0.00 Totals 153.42 153.23 0.19 Percent better than Standard: 0.1% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: [X-] Single Family ❑ Addition Total Conditioned Floor Area: 377 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (N) 0 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 377 ft2 Fenestration: Average Ceiling Height: '9.5 ft Area: 114 ft 2 Avg. U: 0.55 Number of Dwelling Units: 1.00 Ratio: 30.2% Avg. SHGC: 0.44 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area New 1.st-El._HV.A_ C 3Z7 -3,5.82 -1..On Conditioned- -Setback _ _2 -n/a OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U-Fac. Cay. -Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Wall_ Wood_ _228_ _0-074_ -R_t9_ JR-00_-45_-9.0 1X ❑ New 0.9-95 1st-Ooor_Zone Wall_ Wood_ 1-52. _0.07-4__R-1.0-00-.35__9.0 X ❑New_0.9_A5 1_st_Eloor_Zone Wall_ Wood_ t5.6_ _0...0.74_ _R_1.9-i0.0_-22.5__9.0 X ❑New. 0.9=A5 1st-El.00r_Zon.e Wall_ Wood- 110_ _0...0.74_ -RA-9- _R_0.0_ -31.5_-9.0 X ❑ New - .0.9_A5 1.st-Eloor_Zone .Roof Wood_ 37_7_ 0..0.32. _EL3.0_ R-09 -0--22 [X- ❑New .0_1zA17 1.sLEI.00r-Zone Run Initiation Time: 04/18/07 12:36:01 Run Code: 1176924961 EnergyPro 4.3 by EnergySoft User Number: 2266 Job Number: 061664 Page:3 of 9 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Zuniga Casita 4/18/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Tvve Area U -Factor' SHGCZ Azm. Tilt Stat. Glazinq Tvr)e Comments !0 -Window—Rear--(S-W) 72-0 —0 -KO -NERC —225_ _9.0 -dew Double-M.etaI-Loln--E(.5.0.) tst-Eloor-Zone Window Right (N1/u) 42.0 0.550 NFRC 0.44 NFRC 315 90 New Double Metal Low -E U 1st Floor Zone 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 _ THERMAL MASS FOR HIGH MASS DESIGN Run Initiation Time: 04/18/07 12:36:01 Run Code: 1176924961 EnergyPro 4.3 by EnergySoft User Number: 2266 1 Job Number: 061664 Page:4 of 9 Area Thick.Heat . Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val JA iV Reference Status Comments Concrete, Heavvwei hg t 302 4.00 28 0_98 0 26-A1 New 1 st Floor Zone / Slab on Grade Concrete, Heavyweight 75 4.00 28 0_98 2 26-A1 New 1 st Floor Zone / Slab on Grade Insulation PERIMETER LOSSES Location/ Condition Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 64 None No Insulation 26-A1 New 1 st Floor Zone Slab Perimeter 16 None No Insulation 26-A1 New _ 1st Floor Zone Run Initiation Time: 04/18/07 12:36:01 Run Code: 1176924961 EnergyPro 4.3 by EnergySoft User Number: 2266 1 Job Number: 061664 Page:4 of 9 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Zuniga Casita 4/18/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type New 1st FI. HVAC Central Furnace 80%AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? New 1st FI. HVAC Ducted Ducted Attic 6.0 New Yes Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Takagi T -K2 Instant Gas No Pipe Insulation J 185,000 0 New 0.85 0 n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation tEMARKS COMPLIANCE STATEMENT his certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. he undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Troy Lindquist Title/Firm: Architectural Estates Design Studio 'Title/Firm: Alternative Energy Systems Address: 209 E. Ellis Dr. Address: 229 N. Central Ave., Suite 500 Tempe, AZ 85282 Glendale CA 9601 Telephone: 480-683-2077 Lic. #: Telephone: (81 ) 246-2844 Z (signature) (date), (signature / (date) - t Enforcement Agency J V Name: Title/Firm: Address: Telephone: (signature) (date) Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Zuniga Casita 4/18/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies Dasea on the aaequacy of the special JusutIcation and aocumentation suomittea. Plan I Field HIGH MASS Design - Verify Thermal Mass: 302 sgft Exposed Slab Floor, 4.00" thick at 1st Floor Plan HIGH MASS Design - Verify Thermal Mass: 75 sgft Covered Slab Floor, 4.00" thick at 1 st Floor Plan HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a ncr%o provider using approved tesung anuror vermcation metnous. PlateField The HVAC System "New 1 st FI. HVAC' incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "New 1 st FI. HVAC' incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. Run Initiation Time: 04/18/07 12:36:01 Run Code: 1176924961 EnergyPro 4.3 by EnergySoft User Number: 2266 Job Number: 061664 Page:6 of 9 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑ ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑ ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑ ❑ apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed Floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas togs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 pennfinch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El El ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. ❑ ❑ ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. - ❑ ❑ ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped: all joints and penetrations caulked and seated. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable healing and/or cooling systems. ❑ ❑ ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness:, 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, _ ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes avapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space: 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 2266 Job Number: 061664 Page:7 of 9. Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Duds and Fans 1. All duds and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ❑ 7. Flexible duds cannot have porous inner cores: § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high luminaires less than 70 ft) OR by dimmer OR ❑ ❑ ❑ efficacy (except closets are controlled a switch are controlled by an occupant sensor that complies with Section il9(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 2266 Job Number: 061664 Page:8 of 9 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Zuni Casita 4/18/2007 SYSTEM NAME FLOOR AREA New 1st FI. HVAC 377 ENGINEERING CHECKS ISYSTEM LOAD Number of Systems 1 Heating System Output per System 35,000 Total Output (Btuh) 35,000 Output (Btuh/sgft) 92.8 Cooling System Output per System 23,000 Total Output (Btuh) 23,000 Total Output (Tons) 1.9 Total Output (Btuh/sqft) 61.0 Total Output (sgft/Ton) 196.7 Air System CFM per System 1,400 Airflow (cfm) 1,400 Airflow (cfm/sgft) 3.71 Airflow (cfmrron) 730.4 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 ote: values above given at ARI conditions !ATING SYSTEM PSYCHROMETR Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent I CFM I Sensible 1,425 10,081 1,149 387 9,263 Outside Air' 0 1,055 738 0 0 0 0 0 0 0 ROOMS] 0 0 1,055 738 12,191 1,149 10,738 BRYANT 311JAV024045/550AN024 12,018 10,066 35,000 Total Adjusted System Output 12 018 10,066 35,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I F Jan 12 am ream Temperatures at Time of Heating Peak -- O ouNNry nn vuub Outside Air' 0 Cfm 92.5 of Supply Fan Heating Coil 1400 cfm ROOMS] 70.0 of 69.5 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 /7 7.6 of 78.7/69.3 of '78.7 69.4 of 70.6 166.61 of Supply Air Ducts 0 Outside Air 0 cfm Supply Fan Cooling Coil 71.4 / 66.9 OF 1400 cfm ROOMS 64.4% R.H. of 78.0 / 69.1 of 'E.7 / 69.3 Return Air Ducts I EnergyPro 4.3 by EnergySoft User Number: 2266 Job Number: 061664 Paoe:9 of 9 TITLE 24 REPORT 'Title 24 Report for: Zuniga_Residelrnce� Lot 43, Tract 29894-3 La Quinta, CA s Project Designer: Architectural Estates Design- Studio 209 E. Ellis Dr. Tempe, AZ 85282 - 4.80=683-2077 Report Prepared By: - Troy Lindquist Alternative Energy Systems 229 N. Central Ave., Suite 500 Glendale, CA 91203 (818) 246-2844 Job Number: 1656 0 QUINTA CITY ( �` DEPT•°D 2 ©2001 BUILDING & SAFEP te: ,. A'R AP�ROVED FOR CONS UCTION 4/1 2007 By The EnergyPro comp ter progr use a io s summarized in this compliance report. This program has approval and is authorized by the Cali ortjAff Sion fo a esidential and Nonresidential 2005 Building Energy Efficiency Standards. This prq ram developed by EnergyS.oft, LLC www.energysoft.com. EnergyPro 4.3 by EnergySoft -• V Job Number: 061656 User Number: 2266 r Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R _Zu.ni-g..a_Re.s.i.de.n.Ce Total Conditioned Floor Area: 4,259 ft2 41_1.8I2Q0-7 Date ProjecfTitle _LotA3.,_T_ract_298.9_4-3-La_Quinta n/a ft2 Building Front Orientation: (N) 0 deg Project Address 0 ft2 Fuel Type: Building Permit # Altemative_Eae_rg_y_System s 3,421 ft2 (818) 246-2844 _2.,5.84 _0..0.32.0_3.0_ R-0-0-0_22 plan Check/Date Documentation Author Area: 806 ft2 Telephone Number of Dwelling Units: _Ene.rg-yP_r_o Ratio: 18.9% Avg. CAA -Climate -Zone -1-5 Field Check/Date Complia ce Method BUILDING ZONE INFORMATION Climate Zone # of Thermostat TDV Standard Proposed Compliance Units Zone Type Type _(kBtu/sf-yr) Design Design Margin -0110_ -Conditioned- -Setback_ Space Heating 3.63 4.35 -0.72 _0..2.0_ -Conditioned_ --Setback Space Cooling 68.73 66.03 2.70 Fans 9.82 10.12 -0.30 Domestic Hot Water 5.67 6.18 -0.51 Pumps 0.00 0.00 0.00 Totals 87.86 86.68 1.18 Percent better than Standard: 1.3% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: WSingle Family ❑ Addition Total Conditioned Floor Area: 4,259 ft2 [:]Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (N) 0 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 3,421 ft2 Fenestration: _2.,5.84 _0..0.32.0_3.0_ R-0-0-0_22 Average Ceiling Height: 9.8 ft Area: 806 ft2 Avg. U: 0.55 Number of Dwelling Units: 1.00 Ratio: 18.9% Avg. SHGC: 0.45 Number of Stories: 2 BUILDING ZONE INFORMATION 4.3.8_ _0_ - 0..0 _ _315__9.0 .014_ R_ 9 0_0..0-_ # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area -NewIstFI HVA_ C 'A 422 34 918 -0110_ -Conditioned- -Setback_ 8 -n/a _N.ew 2nd_ELHYLIC 838 -7..5.3.8 _0..2.0_ -Conditioned_ --Setback 8 _Na OPAQUE SURFACES Insulation Act. Type Frame Area Ll -Fac. Cay. Cont. Azm. Tilt Wall_ Wood_ 6.08_ _0_07-4_ _R-19.0 0 0- 48 -9.0 Wall_ Wood_ 6.52 _0_014 R_19 R-0-0 135__9.0 Wall_ Wood- 1,7.2.0 -0-07-4- -P-19 R-0_0 _225__9.0. Wall_ Wood_ x.._4.52 _0_OZ - 0=19.0=00_ X15__90 .Roof Wood_ _2.,5.84 _0..0.32.0_3.0_ R-0-0-0_22 Wall_ Wood_ 4.91. -0-014- -R_1.9. 0JL0 4.5_ 9.0 Wall_ Wood_ 4.61. _0_0.24_ _R19.0_0.0 X3.5-90 Wall_ Wood- 428_ _0_.079_ -13_1.9.0_00_-22.5__9.0 Wall_ Wood_ 4.3.8_ _0_ - 0..0 _ _315__9.0 .014_ R_ 9 0_0..0-_ .Roof Wood_ 8.3.8_ 0.0.32.0 30.0=0:.0 _0__22 Gains Condition Y / N Status JA IV Reference Location / Comments X D9 ❑ El ❑New ❑New New _0.9=A5 1.st-ELoor_Zon. e New- 0.9--A5 1stFloorZo.ne 0.9--A5 tst.Eloor_Zons 09--A5 1st-Eloor-Zone El New- 01-A17 1st-ElooLZo.ae X El New- 0;3_A5 2nd_Eloor-Zone El New- 09_A5 2nd-Eloor-Zone F-1 New- -Q9--A5- 2nd_EloonZona A ❑New D9 --A5 2nd- looLZone ❑N.ew 01=A17 2od.Eloor2Zone Run Initiation Time: 04/18/07 11:25:40 Run Code: 1176920740 EnergyPro 4.3 by EnergySoft User Number: 2266 Job Number: 061656 Page:3 of 13 Certificate Of Compliance :Residential (Part 2 of 4) CF -1 R Zuni Residence 4118/2007 Project Title Date FFNFSTRATION RllRFAr-F.R # Tvoe Area True Cond. LI -Factor" SHGCZ Azm. Tilt Stat. Glazing Type L WndowEront_(NE) X3.8_ 2 Window Front (U. 60.0 -0-5-50.NERIC _0.A5 -NERC --A.5_ 0.550 NFRC 0_45 NFRC 45 _90- New Double-matal-Lowes, 90 New Double Metal Low E 3 Window Left _(SE)_8.0 SHGC 0.550 NFRC 0_45 NFRC 135 90 New Double Metal Low E-1 LEA Window ndow Left . 25.0 0.550 NFRC 0_45 NFRC 135 90 New Double Metal Low E' 5 6 . Window Window Left Left (SE). (SE) 8.0 2.3 0.550 NFRC 0_45 NFRC 0.550 NFRC 0_45 NFRC 135 135 90 New 90 New Double Metal Low E Double Metal Low E! 7 Window Left 8(_E). 2.3 0.550 NFRC 0_45 NFRC 135 90 New Double Metal Low E1 8 Window Left (SE) 2.3 0.550 NFRC 0.45 NFRC 135 90 New Double Metal Low E! 9 Window Rear (M 96.0 0.55 NFRC 0_45 NFRC 225 90 New Double Metal Low EI 10 11 window Rear ( 24.5_ Window Rear (SW) 24.5 0.550 NFRC 0.45 NFRC 0.550 NFRC 0_45 NFRC 225 225 90 New 90 New Double Metal Low EI Double Metal Low EI 12 Window Rear (SW) 24.5 0.550 NFRC 0_45 NFRC 225 90 New Double Metal Low EI 13 14 Wadow ReaL-(S" Window Rear (5A -2A5 24.5 -0-50 _N.EB_C 045 NFRC 0.550 NFRC 0_45 NFRC _22.5_ 225 99 NewwQouble-M-etal-W E.I 90 New Double Metal Low EI 15 Window Rear (sqM 16.0 0.550 NFRC 0_45 NFRC 225 90 New Double Metal Low EI 16 17 Window Window Rear (5A Ri ht N 128.0 24.0 0.550 NFRC 0_45 NFRC 0.550 NFRC 0_45 _NERC 225 315 90 New 90 New Double Metal Low E Double Metal Low E 18 Window Right (NW) 22.5 0.550 NFRC 0.45 NFRC 315 90 New Double Metal Low EI 1.9 __Wridow, _Rlaht_ _ (NW) 22.5 0.550-NFRC 0-45 NFRC_315 0.1 90 New Dou_bli Metal Low E 1. Indicate source either from NFRC or Table 116A. 2. Indicate source' either from NFRC or Table 116B. Location/ Comments tsLBoor-Zone 1 st Floor Zone 1 st Floor Zone 1 st Floor Zone 1 st Floor Zone 1 st Floor Zone `) 1 st Floor Zone 1 qt Flnnr 7nna INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC HgL Wd.. Len. ;Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bg Screen 0.76 7 Bug Screen 0.76 _ 8 Bug Screen 0.76 _ 9 Bug Screen 0.76 8.0 12.0 11.0 0.1 11.0 11.0 10 Bug Screen 0.76 4.0 6.0 11.0 0.1 11.0 11.0 11 Bug Screen 0.76 4.0 6.0 11.0 0.1 11.0 11.0 12 Bug Screen 0.76 4.0 6.0 11.0 0.1 11.0 11.0 _ 13 Bug Screen 0.76 4.0 6.0 11.0 _0.1 11.0 11.0 _ 14 Bug Screen 0.76 4.0 6.0 11.0 0.1 11.0 11.0 15 Bug Screen 0.76 8.0 16.0 11.0 0.1 11.0 11.0 16 Bug Screen 0.76 8.0 16.0 11.0 0.1 11.0 11.0 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Type Length R -Val. Location Slab Perimeter 55 JA IV Reference Condition Location/ Status Comments New 1 st Floor Zone New 1 st Floor Zone Run Initiation Time: 04/18/07 11:25:40 Run Code: 1176920740 EnergyPro 4.3 by EnergySoft User Number: 2266 Job Number: 061656 PageA of 13 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Zuniga Residence 4/18/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazing Type Comments .20. -Window-Right-(N-1N) l�E (NE) ---J3Q _0..550 _NERC -0-4.5 _NERC _315_ _9.0 N.ew bauble- etal-Low-E-� 21 Window Right (NN 13.0 0.550 NFRC 0_45 NFRC 315 90 New Double Metal Low E I 22 Window Right (NW) 13.0 0.550 NFRC 0_45 NFRC 315 90 New Double Metal Low E, 23 Window Right (NVV) 13.0 0.550 NFRC 0_45 NFRC 315 90 New Double Metal Low E 24 Window Right (N� 13.0 0.550 NFRC 0_45 NFRC 315 90 New Double Metal Low E 25 Window Right (NW) 20.0 0.550 NFRC 0_45 NFRC 315 90 New Double Metal Low E 26 Window Front (NE) 2.3 0.550 NFRC 0_45 NFRC 45 90 New Double Metal Low E 27 Window Front (NE) 2.3 0.550 NFRC 0.45 NFRC 45 90 New Double Metal Low E 28 Window Front (NE) 7.5 0.550 NFRC 0.45 NFRC 45 90 New Double Metal Low E' _29 30 Window Front_( Window Front l�E (NE) 7.5 0.550 NFRC 0.45 NFRC 7.5 0.550 NFRC 0_45 NFRC 45 90 New 90 New p��ble Metal Low EI Double Metal Low EI 31 Window Front (NE) 7.5 0.550 NFRC 0_45 NFRC 45 90 New Double Metal Low EI 32. 33 Madow-Fsoat_(NE) Window Front --3-5 (NE) 2.3 0 550 -NERC OA5 NFRC 0.550 NFRC 0_45 NFRC 45_ 45 90- N.ew 90 New QoubleJMetaLLQw- E Double Metal Low E 34 Window Front (NE) 2.3 0.550 NFRC 0.45 NFRC 45 90 New Double Metal Low EI 35 Window Front (NSE. 2.3 0.550 NFRC 0_45 NFRC 45 90 New Double Metal Low EI 36 37 Window Window Front Left (NE) (SE) 2.3 2.3 0.550 NFRC 0_45 NFRC 0.550 NFRC 0_45 NFRC 45 135 90 New 90 New Double Metal Low EI Double Metal Low EI 38 Window Left (SE)2.3 Bug Screen 0.550_NFRC -QA5 NFRC 135 90 New Double Metal Low EI 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. 1 st Floor Zone ` 1 st Floor Zone 1 st Floor Zone 1 st Floor Zone 1 st Floor Zone 2nd Floor Zone 2nd Floor Zone 2nd Floor Zone 2nd Floor Zone I 2nd Floor Zone 2nd Floor Zone 2nd-RooLZone 2nd Floor Zone 2nd Floor Zone INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 _ 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 _ 30 Bug Screen 0.76 _ 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 _ 37 Bug Screen 0.76 _ 38 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Tvoe (sf) (in.) Car). Cond. R -Val JA IV.Reference Status Comments PERIMETER LOSSES . TvDe ILe Insulation Condition Location/ R -Val Location JA IV Reference Status Comments Run Initiation Time: 04/18/07 11:25:40 Run Code: 1176920740 EnergyPro 4.3 by EnergySoft User Number: 2266 Job Number: 061656 Page:5 of 13 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Zuniga Residence 4/18/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm Tilt Stat Glazing Type Comments 3.9. -Window—Left—(-S-E) 40 Window Rear (L" _2.3_ 21.3 —0 5.50_NERC__0-A5 -NERC _1-3.5_ 0.550 NFRC 0_45 NFRC 225 _9.0_ New—Double—Metal—Law—E] 90 New Double Metal Low E 41 Window Rear (V)b 12.0 0.550 NFRC 0_45 NFRC 225 90 New Double Metal Low EI 42 Window Rear (V)o 12.0 0.550 NFRC 0_45 NFRC 225 90 New Double Metal Low EI 43 Window Rear (SW) 12.0 0.550 NFRC 0_45 NFRC 225 90 New Double Metal Low EI 44 Window Rear (SW) 5.0 0.550 NFRC 0_45 NFRC 225 90 New Double Metal Low EI 45 Window Rear (SM 12.0 0.550 NFRC 0_45 NERC 225 90 New Double Metal Low E 46 Winnow Roar rRW1 5 n n 55n NFRC n d5 .NFRC 995 an Naw nnuhlo Mortal I nw FI 47 Window Right (NW) 30.0 0.550 NFRC 0_45 NFRC 315 90 2nd_El.00r_Zone i 2nd Floor Zone 2nd Floor Zone 2nd Floor Zone 2nd Floor Zone 2nd Floor Zone 2nd Floor Zone 2nd Floor Zone 2nd Floor Zone 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. Hgt. Dist. Len. Hgt. 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 _ 42 Bug Screen 0.76 _ 43 Bug Screen 0.76 _ 44 Bug Screen 0.76 45 Bug Screen 0.76 _ 46 Bug Screen 0.76 _ 47 Bug Screen 0.76 _ THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Condition Location/ Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 04/18/07 11:25:40 Run Code: 1176920740 EnergyPro 4.3 by EnergySoft User Number: 2266 Job Number: 061656 Page:6 of 13W Certificate Of Compliance : Residential, (Part 3 of 4) CF -1 R Zuniga Residence 4/18/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition _ Thermostat Location Type Eff Type Eff Status Type New 1st FI. HVAC Central Furnace 93%AFUE Split Air Conditioner 14.7 SEER New Setback New 2nd FI. HVAC Central Furnace 93%AFUE Split Air Conditioner 16.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? New 1st FI. HVAC . Ducted Ducted Attic 6.0 New Yes New 2nd FI. HVAC Ducted Ducted Attic 6.0 - New Yes Hydronic Piping Pipe Pipe Insul System Name 'Length Diameter Thick.' WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. AO Smith BT 100 Large Gas No Pipe Insulation t2 75,100 98 New 0.80 2.12% 0.0 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2 Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT Regulations, and the administrative regulations to implement them. This certificate has been signed. by the individual with overall design responsibility. he undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code)., Documentation Author Name: Name: , Troy Lindquist Title/Firm: Architectural Estates Design Studio_ Title/Firm` • Alternative Energy Systems Address: 209 E. Ellis Dr. Tempe, AZ 85282 Telephone: 480-683-2077 tic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: - Telephone: (signature) `(date) ' I EnergyPro 4.3 by EnergySoft User Number: 2266 Job Number: 061656 Page:7 of 13 I Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Zuniga Residence 4/18/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement aaencv determines the adeauacv of the iustification. and may refect a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "A O Smith BT 100" is a Large Gas water heater with Pilot Loss = 0 btuh. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan I Field The HVAC System "New 1 st FI. HVAC' incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CFAR. The HVAC System "New 1 st FI. HVAC' incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "BR355MAV042060F/598BNX060000" includes credit for a 10.4 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "New 2nd FI. HVAC' incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CFAR. The HVAC System "New 2nd FI. HVAC' incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "BR355MAV042040F/598BNX036000" includes credit for a 10.4 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. EnergyPro 4.3 by EnergySoft User Number: 2266 Job Number: 061656 Page:8 of 13 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE. permit application documentation. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. El El El § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑ apply to exterior mass walls). *§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. - El ❑ El § 150(e): Installation of Fireplaces,. Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: , a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑, ❑ ❑ § 150 ft Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16.only. �' ❑, ❑ § 150(1): Slab edge insulation - water absorption rale for .the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 pennfinch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type an6include ❑ ❑ ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfillration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑ ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures y § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Healing and/or cooling loads calculated in accordance with ASH RAE, SMACNA or RCCA. " . ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems.. • ' ` El❑ �❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater.. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank,non-recirculating systems, and entire ❑ El 11length of recirculating sections of hot water -pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A: ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant:or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 2266 Job Number: 061656 Page:9 of 13 t Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE DESCRIPTION applicable. NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Duds and Fans 1. All duds and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and return -air duds and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system , that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 114 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. " ❑ ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation!Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ❑ ❑ 7. Flexible duds cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: � ❑ ❑ a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch.- ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑' ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑ ❑ controlled by an occupant sensor that complies with Section f19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 2266 Job Number: 061656 Page:10 of 13 Residential Kitchen Lighting Worksheet WS -5R Zuniga Residence 4/18/2007 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1)26w Compact Fluorescent Triple 4 Pin Yes X No 37.0 x14 = 518 or Yes No x = or Yes No' x or Yes No x - or Yes No x _ or Yes No x - or Yes No x = or Yes No x = or Yes No. x _ or Yes No x = or Yes, No x _ or Yes No x. = or Yes No I x _ or Yes -No x _ or Yes No x- or Yes No x , - or Yes No x _ or Yes No x or Yes No x' = or Yes No x = or Total A: 518 B: 0 - COMPLIES IF A >_ B YES [X_ I 'NO ❑ EnergyPro 4.3 by EnergySoft User Number: 2266 Job Number: 061656 Page: 11 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Zuniga Residence 4/18/2007 SYSTEM NAME FLOOR AREA New 1 st FI_ HVAC 3.422 Number of Systems t Heating System Output per System 56,000 Total Output (Btuh) 56,000 Output (Btuh/sqft) 16.4 Cooling System Output per System 58,000 Total Output (Btu h) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sqft) 17.0 Total Output (sgft/Ton) 708.0 Air System CFM per System 1,400 Airflow (cfm) 1,400 Airflow (cfm/sgft) 0.41 Airflow (cfm/Ton) 289.7 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions 26.0 OF 3� Outside Air 0 cfm 67.5 OF :OOLING S 11.0 / 77.6 OF Outside �� 0 cfm 81.1161.2 OF 67.5 OF 67.5 OF SYSTEM Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent I CFM I Sensible 1,754 49,536 4,591 1,634 56,511 0 4,582 3,784 0 0 0 0 0 0 0 0 0 4,582 3,784 58,699 4,591 64,079 BR355MAV042060F/598BNX060000 48,708 0 56,000 Total Adjusted System Output 48 708 0 56,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK J Aug 2 pm Jan 12 am ream Temperatures at Time of Heatina Peak) 105.0 OF Supply Fan Heating Coil 1400 cfm Supply Air Ducts 102.5 OF ROOMS 70.0 OF Return Air Ducts I 81.1/61.2 OF 81.1/61.20F int 48.4/46.80F O Supply Fan 1400 cfm 4.3 by EnergySoft User Number: 2266 Cooling Coil . Return Air Ducts Job Number: 061656 in Supply Air Ducts 51.5 / 48.2 OF 34.5% R.H. ROOMS 78.0 / 60.1 OF 12 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Zuniga Residence 4/18/2007 SYSTEM NAME FLOOR AREA New 2nd FI. HVAC 838 °NGINEERING CHECKS Number of Systems 1 Heating System Output per System 38,000 Total Output (Btuh) 38,000 Output (Btuh/sqft) 45.4 Cooling System Output per System 35,000 Total Output (Btuh) 35,000 Total Output (Tons) 2.9 Total Output (Btuh/sqft) 41.8 Total Output (sgft/Ton) 287.1 Air System CFM per System 1,400 Airflow (cfm) 1,400 Airflow (cfm/sgft) 1.67 Airflow (cfm/Ton) 480.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK ICOILHTG.PEAKI CFM I Sensible Latent I CFM I Sensible 1,520 17,475 1,728 568 14,611 0 1,616 978 0 0 0 0 0 0 0 0 0 1,616 978 20,708 1,728 16,567 BR355MAV042040F/598BNX036000 19,326 14,468 38,000 Total Adjusted System Output 19,326 14,468 38,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 F Jan 12 am 1EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating_ Peak) _ 26.0 OF 69.3 OF 69.3°F 94.8 OF Supply Air Ducts Outside Air 0 cfm , . 94.2 OF Supply Fan Heating Coil 1400 cfm ROOMS 70.0 OF 69.3 OF I Return Air Ducts :DOLING S i 1.0177.6 OF Outside Air 0 cfm 79.1 /69.6 OF 69.6 OF 79.1 169.7 OF 66.1/6530 F Supply Fan Cooling Coil 1400 cfm EnergyPro 4.3 by EnergySoft User Number: 2266. Return Air Ducts Job Number: 061656 Supply Air Ducts 67.2 / 65.7 of 65.2% R.H. ROOMS 78.0 69.3 OF I 13 of 13