Loading...
10-0038 (AR)__T_ P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 10-00000038 'Prope� rrty`Ad`dress. —477655—VIA MONTIGO APN: 643-120-031-259 -26152 - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 20927 Applicant: 7NI Tity/ 4 4 4" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Architect or Engineer: Owner: HAVAS JAMES EDWARD *NOT ON FILE UNKNOWN, CA 99999 Contractor: DESERT CONTRACTING INC 83046 LONGCAVE DRIVE BERMUDA DUNES, CA 922a (760)449-4029 j L,iC. No.: 904718 I VOICE (760) 777-7012 FAX (760) 777-7011' INSPECTIONS (760) 777-7153 Date: 2/24/10 Z;t;l Gii/ r);t LA QWNTA _ _ -------------------------------------------------------------------------------?r:;.T, - --- LICENSED CONTRACTOR'S DECLARATION - I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. Vol*' License Class: B-��C223/3 License No.: 04718 Date: � t,�Contractor. MM LV OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, Will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). f 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed f=� pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. , B.&P.C. for this reason -, Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). ' Lender's Name: _ Lender's Address: LQPERDIIT WORKER'S COMPENSATION DECLA V'— _ ]'hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation_ insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section. / 3700 of Labor Code, I shA Lf hzth c ply 'th ose provisions. . Date: � (0 /AApplicant: WARNING:' FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN' SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. - APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. ' 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construct' n, and hereby aut rize representatives of This co myenter on the above-mentioned property for in ct' puse D/ate: nature (Applicant or Agent): LQPERNIIT Application Number . . . . . 10-00000038 ------ Structure Information 259 ADDITION TO 3010 EXISTING ----- Construction Type . . . . . TYPE V, UNPROTECTED Occupancy Type . . . . . DWELLG/LODGING/CONG <=10 Other struct info . . . . .. CODE EDITION 2007/08 EN # BEDROOMS .00 FLOOD ZONE NO GARAGE SQ FTG .00 PATIO SQ FTG .00 - 1ST FLOOR SQUARE FOOTAGE 259.00 ---------------------------------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE .00 Permit BUILDING PERMIT Additional desc 259 SF GAME RM. ADDITION Permit_Fee . . . 216..00 Plan Check Fee 140.40 Issue -Date Valuation 20927 Expiration Date 8/23/10 Qty Unit.Charge. Per' Extension . BASE FEE. 45.00 19.00 9.0000 THOU BLDG'2,001-25,000 171.00 Permit . . ELECT - ADD/ALT/REM Additional desc . Permit Fee 32.18 Plan Check Fee 8.05 Issue Date . . . Valuation 0 Expiration Date 8/23/10 Qty Unit Charge Per Extension BASE FEE 15.00 259.00 0200 ELEC GARAGE OR NON-RESIDENTIAL' 5.18 16.0.0 .;7500 PER ELEC DEVICE/FIXTURE 1ST 20 12..0-0 Permit ' MECHANICAL Additional desc . Permit Fee . . . . 19.50 Plan Check Fee 4.88. Issue Date . . . . Valuation 0 Expiration Date 8/23/10 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT - 4.50 ------------------------------------.---------------------------------------- Special Notes and Comments �! 259 SF GAME RM ADDITION TO EXISTING 3010 LQPERNIIT LQPE%AIIT Application Number . . . . . 10-.0.0000038 ---------------------------------------------------------------------------- Special Notes and Comments SF SINGLE FAMILY RESIDENCE.R3 OCC. TYPE V -B CONSTR.2007 CODES, 2008 ENERGY CODES. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 ENERGY REVIEW FEE 14.04 STRONG MOTION (SMI) - RES 2.09 Fee 'summary Charged Paid Credited Due Permit Fee Total 267.68 .00 .00 267.68 Plan Check Total 153.33 .00 .00 153:33 Other Fee Total" 17.13 .00 .00 17.13 Grand Total 438.14 .00 .00 438.14 rc LQPE%AIIT Bib �# 3D City of La Quinta -Building ff Safety. Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # ID �' -0D Project Address:41+S9 S5 QIQ tAoAtj qo _ Qdj h Owner's Name: A. P. Number: ?> 12� .. 03 Address:44-. 7,-S& Legal Description: ' C✓ —30 City, ST, Zip: R CA 01 S3 Contractor: L �II hone: Telephone: I Address: $ 3-4C)W Wve.teive. Project Description: w :City, ST, Zip: til . Q CA 1 � pp A4 "' C R V ne• Telephone: P I .................................. >> State Lic. # : Q City Lic. #:, Arch., Engr., Designer MWp_ VWAa Address: City., ST, Zip: S C4 Q Te1e hone: g Lic. #: Construction TYPe: Occupancy: Project type circle one New Add nAlter Repair Demo Name of Contact Person: Sq. Ft.: `q . O # Stories: 1 #Units: Telephone # of Contact Person: k 2 —• 1.9 1 �0 I Estimated Value of Project: 11F �OG� APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready fo co rection, 2 / Plan Check Deposit , Truss Calcs. Called Contact Person 1- Plan Check Balance. Title 24 Calcs. �7 Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2nd Review, ready for correction issue . Z Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees • /l1&;-- ivy ter, /Z/� 7 IV -5 A'/m F CERTIFICATE OF COMPLIANCE ���1FIF�Sc� Desert Sands Unified.School District Zq < 47950 Dune Palms Road - t • Q BERMUDADUNES 7 Date 2/26/10i La Quinta, CA 92253 - n RANCHO MIRAGE b r INDIAN WELLS "ter r' No. 30619 (7vO' 771-8515 fir`, PALM DESERT V LA QUINTA a INDIO Owner M/M James Havas APN # 643-120-031 Address 47-655 Via Montigo Jurisdiction City La Quinta Zip 92253 Permit # Tract # No. of Units 1 Type Residential Addition Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 47655 Via Montigo 259 Unit 6 Unit 2 = 'Unit 7 Unit 3 y Unit 8 Unit 4 Unit 9 r v Unit 5 �' `. Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5 - 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: • Residential Addition 500 Sq Feet or Less . EXEMPT r This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. { in the amount of $0.00 X 259 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By N/A -Michael Aspell Check No. N/A Name on the check Telephone 760-449-4029 .� • {. Funding•• Exempt By Dr. Sharon P' McGehee Superintendent a Fee collected /exempted b Payment Recd =" - p Y Yolanda Garcia $o.00 Over/Urder , Signaturex NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant - Copy 7 Applicant/Receipt Copy - Accounting i 7603464349 1&W Managment comps 03:26:14 p.m. 02-06-2010 2/2 LAKE LA QUI -W, HOMEOWNERS ASSOCIATION CIO - & W MANAGEMENT P.O. BOX 1398, PALM DESERT, CA 92261 760 568-0349 February 8, 2010 James and -Sheela'-Havas 47655 Via Montigo RECEIVED La Quinta, CA 92253 FEB 10.2010 BY: Dear Mr. and Mrs. Havas, This -letter is to follow up with the verbal okay you received regarding the addition of a game room to.your home. The Architectural committee has approved your request. Please keep these copies for your records and a copy is here in the office as well. Thank you, i Sylvia Corsini CCAMe For the Board of Directors Lake La -Quints BUILDING ENERGY ANALYSIS REPORT PROJECT: James & Sheela Havas 47655 Via Montego La Quinta, Ca 92253 Project Designer:- 'MIKE MENDOZA P. O. BOX 692 Desert Hot Springs, Ca 92240 1-(760) 275-1816 Report Prepared by: Santiago Lopez-Ocampo Santiago Lopez-Ocampo C i TY UF � Q U I N TA P.O. Box 1018 La Quinta, Ca 92247 BUILDING & SAFETY DEPT. 760.485.8927 APPROVED FOR CONSTRUCTION DATE Z 7.6 Ay 1040 OW �ECEI`V ED Job Number: 010410 Corr. FEB 10 2010 Date: yT: 2/9/2010 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. if UF-'�F t ems... �: .._ `E .r,, � .. �, PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name James & Sheela Havas Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 219/2010 Project Address 47655 Via Montego La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,269 Addition 259 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Slab Unheated Slab -on -Grade None 3,010 Existing Wall Wood Framed R-13 2,776 Existing Door Opaque Door None 72 Existing Roof Wood Framed Attic R-19 2,693 Existing Slab Unheated Slab -on -Grade None 259 New Wall Wood Framed R-21 272 New Roof Wood Framed Attic R-38 259 Radiant Barrier New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Right (N) 100.0 0.870 0.70 none none Bug Screen Existing Right (N) 6.0 0.510 0.66 none none Bug Screen Existing Rear (NM 15.0 0.870 0.70 none none Bug Screen Existing Rear (W) 192.0 0.870 0.70 none none Bug Screen Existing Left (S) 88.0 0.870 0.70 none none Bug Screen Existing Front (E) 48.0 0.870 0.70 none none Bug Screen Existing Right (N) 30.0 0.510 0.34 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback Existing 1 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC System - Main Hous Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing HVAC System - Guest Hou Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro5.O by Ener Soft User Number: 5732 RunCode: 2010-02-09T10:51:2 ID: 010410 Corr. Page 3 of 13 PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF -1 R Project Name James & Sheela Havas Building Type 0 Single Family 0 Addition Alone 0 Multi Family 0 Existing+ Addition/Alteration Date 2/9/2010 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Existing Furnace Default FAU/AC 1992 - 2005 has an AFUE less than the Vintage Defaults. Field verification is required. The Existing Air Conditioner Default FAU/AC 1992 - 2005 has an SEER less than the Vintage Defaults. Field verification is required. HIGH MASS Design - Verify Thermal Mass: 1, 813.0 ft' Exposed Slab Floor, 3.500" thick at Main House HIGH MASS Design - Verify Thermal Mass: 880.0 ft' Covered Slab Floor, 3.500" thick at Main House The Existing Furnace Default FAU/AC 1992 - 2005 has an AFUE less than the Vintage Defaults. Field verification is required. HIGH MASS Design - Verify Thermal Mass: 51.0 ft2 Exposed Slab Floor, 3.500" thick at Guest House HIGH MASS Design - Verify Thermal Mass: 266.0 ft2 Covered Slab Floor, 3.500" thick at Guest House HIGH MASS Design - Verify Thermal Mass: 259.0 ft2 Exposed Slab Floor, 4.000" thick at Addition The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Ener Pro 5.0 by Energ ySoft User Number: 5732 RunCode: 2010-02-09T10:51:2 ID: 010410 Corr. Page 4 of 13 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date James & Sheela Havas ❑ Multi Family m Existing+ Addition/Alteration 219/2010 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 6.58 5.29 1.28 Space Cooling 165.68 162.82 2.86 Fans 34.07 33.46 0.61 Domestic Hot Water 11.16 11.16 0.00 Pumps 0.00 0.00 0.00 Totals 217.48 212.72 4.75 Percent Better Than Standard: 2.2% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 618 48 Fuel Available at Site: Natural Gas (S) 1,003 88 Raised Floor Area: - 0 (tM 598 207 Slab on Grade Area: 3,269 (N) '1,379 136 Average Ceiling Height: 10.0 Roof 2,952 0 Fenestration Average, U- Factor: 0.64 TOTAL: 479 Average SHGC: 0.68 Fenestration/CFA Ratio: 14.7% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Santiago Lopez-Ocampo ;�J 0 2/9/2010 P.O. Box 1018 Santiago to ez-Ocam Name ame o 9 p p City/State/ZipCity/State/Zip La Quinta, Ca 92247 Phone 760.485.8927 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other'compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company MIKE MENDOZA Address P. O. BOX 692 ® O Name 20 . City/State/Zip Desert Hot Springs, Ca 92240 Phone 1-(760) 275-1816' Signed Lic (rise # Date Ener Pro 5.0 by Ene Soft User Number. 5732 RunCode: 2010-02-09T10:51:2 /D: 010410 Corr. Page 5 of 13 19 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name .. James & Sheela Havas Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 2/9/2010 OPAQUE SURFACE DETAILS Surface Type Area Ll- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 1,813 0.730 None - 0 180 1 Existing 4.4.7-A1 Main House Slab 880 0.730 None 0 180 Existing 4.4.7-A 1 Main House . Wall 746 0.102 R-13 0 90 Existing4.3.1-A3 Main House Wall 35 0.102 R-13 315 90 Existing 4.3.1-A3 Main House Wall 356 0.102 R-13 2701 90 Existing 4.3.1-A3 Main House Wall 35 0.102 R-13 0 -90 Existing 4.3.1-A3 Main House Wall 715 0.102 R-13 180 90 Existing 4.3.1-A3 Main House Wall 388 0.102 R-13 90 90 Existing 4.3.1-A3 Main House Door 24 0.500 None 90 . 90 Existing 4.5.1-A4 Main House Door 48 0.500 1 None 90 90 Existing 4.5.1-A4 Main House Roof 2,693 0.049 R-19 0 18 Existing 4.2.1-A4 Main House Slab 51 0.730 None 0 180 Existing 4.4.7-A1 Guest House Slab 266 0.730 None 0 180 Existing 4.4.7-A 1 Guest House Wall 191 0.102 R-13 1 01 90 1 Existin 4.3.1-A3 Guest House Wall 200 0.102 R-13 -1 1801 90 1 Existing 4.3.1-A3 Guest House Wall 110 0.102 R-13 1 901 90 1 Existing 4.3.1-A3 Guest House FENESTRATION SURFACE DETAILS ID Type Area LI -Factor SHGC Azm Status GlazingType Location/Comments 1 Window 15.0 0.870 NFRC' 0.70 NFRC' 0 Existing 2001 Build. EnergyStd Mtl-DefClr Main House 2 Window 6.0 0.870 NFRC 0.70 NFRC 0 Existing 200 1 Build. EnergyStd Mtl-DefC/ Main House 3 Window 3.0 0.510 NFRC 0.66 NFRC 0 Existin Pittsburgh ComingGB 12x12 Main House 4 Window 3.0 0.510 NFRC 0.66 NFRC 0 Existing Pittsburgh Corning GB 12x12 Main House 5 Window 30.0 0.870 NFRC 0.70 NFRC 0 Existing 200 1 Build. EnergyStd Mtl-DefC/ Main House 6 Window 15.0 0.870 NFRC 0.70 NFRC 315 Existing 12001Build. EnergyStd Mtl-DefClr Main House 7 Window 64.0 0.870 NFRC 0.70 NFRC 270 Existing 2001 Build. EnergyStd Mtl-DefClr Main House 8 Window 19.5 0.870 NFRC 0.70 NFRC 270 Existing, 200 1 Build. EnergyStd Mtl-DefClr Main House 9 Window 64.0 0.870 NFRC 0.70 NFRC 270 Existing - 2001 Build. EnergyStd Mtl-DefClr Main House 10 Window 19.5 0.870 NFRC 0.70 NFRC • 270 Existing. 2001 Build. EnergyStd Mtl-DefClr Main House 11 Window 25.0 0.870 NFRC . 0.70 NFRC 270 Existing 2001 Build. EnergyStd Mtl-DefClr Main House 12 Window 15.0 0.870 NFRC 0.70 NFRC 0 Existing 2001 Build. EnergyStd Mtl-DefClr Main House 13 Window 20.0 0.870 NFRC 0.70 NFRC 180 Existing 2001Build.Energ Std Mtl-DefClr Main House 14 Window 20.0 0.870 NFRC 0.70 NFRC 180 Existing 2001 Build. EnergyStd Mti-DefClr Main House 15 Window 48.0 0.870 NFRC 0.70 NFRC 180 Existing 2001 Build. EnergyStd Mtl-DefClr Main House 16 Window 9.0 0.870 NFRC . 0.70 NFRC 0 Existing 2001 Build. EnergyStd M DefClr Guest House (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-8 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC Hat Wd Ove hang Left Fin Right Fin Len HqA LExt REM Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 - 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen .0.76 7 Bug Screen 0.76 . 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 - 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 JBug Screen 0.76 Ener Pro 5.0 by Ener Soft User Number: 5732 RunCode: 2010-02-09T10:51:2 ID: 010410 Corr. Page 6 of 13 a - ..-- �� _ '• � _ � of s .+ CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name James & Sheela Havas Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 2/9 2010 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix T e Area Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 259 0.730 None 01 180 1 New 4.4.7-A1 Addition Wall 138 0.069 R-21 0 90 New 4.3.1-A6 Addition Wall 133 0.069 R-21 0 90 New 4.3.1-A6 Addition Roof 259 0.025 R-38 0 0 New 4.2.1-A21 Addition FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 17 Window 48.0 0.870 NFRC 0.70 1 NFRC 90 Existing 2001 Build. EnergyStd Mtl-DefClr Guest House 18 Window 25.0 0.870 NFRC 0.70 NFRC 0 Existing 2001 Build. EnergyStd Mtl-DefClr Addition 19 Window 15.0 0.510 NFRC 0.34 NFRC 0 New General Aluminum Company Addition 20 Window 15.0 0.510 NFRC 0.34 NFRC 0 New General Aluminum Company Addition (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H t Wd Ove hang Left Fin Right Fin Len Hclt LExt RExt Dist Len H t Dist Len I H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 Ener Pro 5.0 by Ener Soft User Number: 5732 Run Code: 2010-02-09T10:51:2 ID: 010410 Con-. Pae 7 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name James & Sheela Havas Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 2/9/2010 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ff New Existinq Altered Removed Volume Year Built HVAC System - Main House Main House 2,693 26,930 2000 HVAC System - Guest House Guest House 317 3,170 1998 Addition 259 2,590 i Totals 2591 3,010 0 0 HVAC SYSTEMS System Name Qty. Heating Ty 'e Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System - Main House 1 Central Furnace; 78% AFUE Split Air Conditioner 9.7 SEER Setback Existing HVAC System - Guest House 1 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback Existing 1 i I HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC System - Main House Ducted ; Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing HVAC System - Guest House Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing I ❑ i ❑ WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas Kitchen Pipe Ins 40,000 50 0.58 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E w Hot Water Piping Length , ft Q c —I System Name Pipe Length Pipe Diameter Insul. Thick. Q HP j Plenum Outside Buried ❑ ❑ ❑ ❑ ❑ ❑ Ener Pro 5.0 by Ener Soft User Number: 5732 RunCode: 2010-02-09T10:51:2 ID: 010410 Con. Page 8 of 13 MANDATORY MEASURES SUMMARY: Residential- Pae 1 of 3 MF -1 R, Project Name Date James & Sheela Havas 2/9/2010, NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in' the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 4" I 116(a)l: Doors and windows between conditioned and unconditioned s aces are manufactured to limit air leakage §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U=Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the Ye uirements of 10-111 a 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1.R Form. *§150(a): Minimum R-19 insulation in wood-frameceilin orequivalent U -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed desi n labeled R -Value. *§150(c): Minimum R-13 insulation in wood-framelwall orequivalent LI -factor., 150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor." 150 f : Air retarding wrap is tested labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no areater than 2.0perm/inch and shall beprotected rotected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket,.when that indoor air is vented to the outside of the building, are prohibited. 1 Space Conditioning, Water Heating and Plumbing System Measures: ' §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §1 13(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflowprevention; pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than .150 Btu/hr are exempt), and pool and spa heaters. I 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internalinsulation where the internal insulation R -value is indicated on the exterior. of the tank. I ' §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per, Standards Table 150-13. _- §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. It I 150(j)3A: Insulation is protected from damage, in1cludinthat due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. k '` 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. ' Registration Number: Registration Date/Time: HERS Provider: EnergyPro 5.0 by EnergySoft User Number: 5732 RunCode: 2010-02-09T751:25 ID: 010410 Co, Page 9 of 13 r MANDATORY MEASURES SUMMARY.: Residential _ ' (Page 2 of 3 MF -1 R Project Name Date James & Sheela Havas 2/9/2010 §150(m)l : All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 1181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is . used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed - sheet metal, duct board or flexible duct shall not be used for conveying •conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. I - §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. ' §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. l Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on=off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot libht. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat , pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ro rammed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: I §150(k)l : High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy.luminaire asspecified by §150(k)2. §150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated .13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. II r ' §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. .1 1 ' 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.' §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet; and utility rooms are high efficacy and controlled by a manual -on occupant sensor. j §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. 4 - Registration Re istration Number: r Registration Date/Time: HERS Provider: EnergyPro 5.0 by EnergySoft User Number: 5732 RunCode: 2010-02-09710:51:25 ID: 010410 Con-. Page 10 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date James & Sheela Havas 2/9/2010 §150(k)11: Permanently installed luminaires locatedl in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceili6gs shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when testi d in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housingand ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exception to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is'automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five wafts of power as determined accoAng to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. 1 ( I t f Registration Number: Registration Date/Time: HERS Provider: Ener Pro 5.0 by Ener Soft User Number: 5732 RunCode: 2010-02-09T10:51:25 ID: 010410 Corr. Pae 11 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name James & Sheela Havas l Date 2/9/2010 System Name HVAC System - Main House Floor Area 2,693 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 2,097 Return Vented Lighting Return Air Ducts Return Fan Ventilation f7 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 0 46,860 2,703 1,110 38,982 Total Output Btuh 0 0 Output Btuh/s tt 0.0 5,224 3,393 Cooling System 0 0 Output per System 1 0 0 0 0 Total Output Btuh 1 0 2,703 0 Total Output ons 0.0 5,224 3,393 Total Output Btuh/s ft 0.0 Total Output s ft/Ton 32,316,000.0 57,307 45,768 Air System CFM perSystem' '0 HVAC1EQUIPMENT SELECTION Airflow cfm 0 Default FAU/AC 1992 - 2005 1 0 0 Airflow cfm/s ft 0.00 Airflow cfm/Ton 0.0 I Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 1 0 1 0 Aug 3 PM I Jan 1 AM Outside Air cfm/s tt 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 68 OF 68 OF 105 OF f t Heating Coil ! I 103 OF ... _ .......... _... . ...... .. ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 0 cfm 80/63°F 80/64°F 55/54°F Cooling Coil I F.E.- 4 { 57 / 54 OF 43.1 % ROOM ROOM 78/63°F EnergyPro 5.0 by EnergySoft User Number: 5732 RunCode: 2010-02-09710:51:25 ID: 010410 Corr. Pege 12 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name James & Sheela Havas Date 2/9/2010 System Name HVAC System - Guest House 1 Floor Area 576 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 I COIL CFM Total Room Loads 628 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING Sensible 14,031 0 1,346 0 0 0 1,346 1 16,724 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output perSystem 0 1,007 249 8,761 Total Output Btuh 0 Output Btuh/s tt 0.0 763 Cooling System 0 Output perSystem 1 0 0 0 Total Output Btuh 1 1,007 0 Total Output ons 0.0 763 Total Output Btuh/s tt 0.0 Total Output s ftfTon 6,912,000.0 10,286 Air System CFM perSystem 0 HVACIEQUIPMENT SELECTION Airflow cfm 0 Default FAU/AC 1992 - 2005 1 0 0 Airflow cfm/s ft 0.00 Airflow cfm/Ton 0.0 Total Adjusted System Output (Adjusted for Peak Design conditions) ! TIME OF SYSTEM PEAK 1 0 0 Aug 3 PM Jan 1 AM Outside Air °i° 0.0% Outside Air cfm/s tt 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 68 OF 1 68 OF 105 OF, Heating Coil , I Ll1 f _ 103 OF ROOM - 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 80/64°F I , 80/64°F 55/54°F f Cooling Coil I 57 / 55 OF 44.7% ROOM Y . 78/63°F EnergyPro 5.0 by EnergySoft User Number: 5732 RunCode: 2010-02-09T10:51:25 /D: 010410 Corr. Page 13 of 13