10-0038 (AR)__T_
P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
10-00000038
'Prope� rrty`Ad`dress.
—477655—VIA MONTIGO
APN:
643-120-031-259 -26152 -
Application description:
ADDITION - RESIDENTIAL
Property Zoning:
LOW DENSITY RESIDENTIAL
Application valuation:
20927
Applicant: 7NI
Tity/ 4 4 4"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Architect or Engineer:
Owner:
HAVAS JAMES EDWARD
*NOT ON FILE
UNKNOWN, CA 99999
Contractor:
DESERT CONTRACTING INC
83046 LONGCAVE DRIVE
BERMUDA DUNES, CA 922a
(760)449-4029 j
L,iC. No.: 904718 I
VOICE (760) 777-7012
FAX (760) 777-7011'
INSPECTIONS (760) 777-7153
Date: 2/24/10
Z;t;l
Gii/ r);t
LA QWNTA _ _
-------------------------------------------------------------------------------?r:;.T, - ---
LICENSED CONTRACTOR'S DECLARATION -
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
Vol*' License Class: B-��C223/3 License No.: 04718
Date: � t,�Contractor. MM LV
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, Will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
f 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
f=� pursuant to the Contractors' State License Law.).
( ) I am exempt under Sec. , B.&P.C. for this reason
-, Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.). '
Lender's Name: _
Lender's Address:
LQPERDIIT
WORKER'S COMPENSATION DECLA V'— _
]'hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation_
insurance carrier and policy number are:
Carrier EXEMPT Policy Number EXEMPT
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section.
/ 3700 of
Labor Code, I shA Lf hzth c ply 'th ose provisions. .
Date: � (0 /AApplicant:
WARNING:' FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN'
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. -
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application. '
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
1 certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construct' n, and hereby aut rize representatives
of This co myenter on the above-mentioned property for in ct' puse
D/ate: nature (Applicant or Agent):
LQPERNIIT
Application Number .
. . . . 10-00000038
------ Structure Information
259 ADDITION TO 3010 EXISTING
-----
Construction Type . .
. . . TYPE V, UNPROTECTED
Occupancy Type . .
. . . DWELLG/LODGING/CONG <=10
Other struct info . .
. . .. CODE EDITION
2007/08 EN
# BEDROOMS
.00
FLOOD ZONE
NO
GARAGE SQ FTG
.00
PATIO SQ FTG
.00
-
1ST FLOOR SQUARE FOOTAGE
259.00
----------------------------------------------------------------------------
2ND FLOOR SQUARE FOOTAGE
.00
Permit
BUILDING PERMIT
Additional desc
259 SF GAME RM. ADDITION
Permit_Fee . . .
216..00 Plan Check Fee
140.40
Issue -Date
Valuation
20927
Expiration Date
8/23/10
Qty Unit.Charge.
Per'
Extension .
BASE FEE.
45.00
19.00 9.0000
THOU BLDG'2,001-25,000
171.00
Permit . .
ELECT - ADD/ALT/REM
Additional desc .
Permit Fee
32.18 Plan Check Fee
8.05
Issue Date . . .
Valuation
0
Expiration Date
8/23/10
Qty Unit Charge
Per
Extension
BASE FEE
15.00
259.00 0200
ELEC GARAGE OR NON-RESIDENTIAL' 5.18
16.0.0 .;7500
PER ELEC DEVICE/FIXTURE 1ST 20
12..0-0
Permit '
MECHANICAL
Additional desc .
Permit Fee . . . .
19.50 Plan Check Fee
4.88.
Issue Date . . . .
Valuation
0
Expiration Date
8/23/10
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 4.5000
EA MECH VENT INST/ DUCT ALT -
4.50
------------------------------------.----------------------------------------
Special Notes and Comments
�! 259 SF GAME RM ADDITION
TO EXISTING 3010
LQPERNIIT
LQPE%AIIT
Application Number . . . . .
10-.0.0000038
----------------------------------------------------------------------------
Special Notes and Comments
SF SINGLE FAMILY RESIDENCE.R3
OCC. TYPE
V -B CONSTR.2007 CODES, 2008 ENERGY
CODES.
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
BLDG STDS ADMIN
(SB1473)
1.00
ENERGY REVIEW
FEE
14.04
STRONG MOTION
(SMI) - RES
2.09
Fee 'summary Charged
Paid
Credited
Due
Permit Fee Total 267.68
.00
.00
267.68
Plan Check Total 153.33
.00
.00
153:33
Other Fee Total" 17.13
.00
.00
17.13
Grand Total 438.14
.00
.00
438.14
rc
LQPE%AIIT
Bib �#
3D
City of La Quinta
-Building ff Safety. Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
ID �' -0D
Project Address:41+S9 S5 QIQ tAoAtj qo
_ Qdj h
Owner's Name:
A. P. Number: ?> 12� .. 03
Address:44-. 7,-S&
Legal Description: ' C✓ —30
City, ST, Zip: R CA 01
S3
Contractor: L
�II
hone:
Telephone: I
Address: $ 3-4C)W Wve.teive.
Project Description: w
:City, ST, Zip: til . Q
CA
1
� pp
A4 "' C R V
ne•
Telephone:
P I
..................................
>>
State Lic. # : Q City Lic. #:,
Arch., Engr., Designer MWp_ VWAa
Address:
City., ST, Zip: S C4
Q
Te1e hone: g
Lic. #:
Construction TYPe: Occupancy:
Project type circle one New Add nAlter
Repair Demo
Name of Contact Person:
Sq. Ft.: `q . O
# Stories: 1
#Units:
Telephone # of Contact Person: k 2
—• 1.9 1 �0
I Estimated Value of Project: 11F �OG�
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready fo co rection,
2 /
Plan Check Deposit
,
Truss Calcs.
Called Contact Person
1-
Plan Check Balance.
Title 24 Calcs.
�7
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2nd Review, ready for correction issue
. Z
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
•
/l1&;-- ivy ter,
/Z/� 7 IV -5 A'/m
F CERTIFICATE OF COMPLIANCE ���1FIF�Sc�
Desert Sands Unified.School District Zq <
47950 Dune Palms Road - t • Q BERMUDADUNES 7
Date 2/26/10i La Quinta, CA 92253 - n RANCHO MIRAGE b
r INDIAN WELLS "ter r'
No. 30619 (7vO' 771-8515 fir`, PALM DESERT
V LA QUINTA
a INDIO
Owner M/M James Havas APN # 643-120-031
Address 47-655 Via Montigo Jurisdiction
City La Quinta Zip 92253 Permit #
Tract # No. of Units 1
Type Residential Addition
Lot # No. Street S.F. Lot # No. Street S.F.
Unit 1 47655 Via Montigo 259 Unit 6
Unit 2 = 'Unit 7
Unit 3 y Unit 8
Unit 4 Unit 9 r v
Unit 5 �' `. Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5 -
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
• Residential Addition 500 Sq Feet or Less
. EXEMPT r
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq. {
in the amount of $0.00 X 259 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By N/A -Michael Aspell Check No. N/A
Name on the check Telephone 760-449-4029
.� • {. Funding•• Exempt
By Dr. Sharon P' McGehee
Superintendent a
Fee collected /exempted b Payment Recd =" -
p Y Yolanda Garcia $o.00
Over/Urder ,
Signaturex
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees o
r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant - Copy 7 Applicant/Receipt Copy - Accounting
i 7603464349 1&W Managment comps 03:26:14 p.m. 02-06-2010 2/2
LAKE LA QUI -W, HOMEOWNERS ASSOCIATION
CIO - & W MANAGEMENT
P.O. BOX 1398, PALM DESERT, CA 92261
760 568-0349
February 8, 2010
James and -Sheela'-Havas
47655 Via Montigo RECEIVED
La Quinta, CA 92253
FEB 10.2010
BY:
Dear Mr. and Mrs. Havas,
This -letter is to follow up with the verbal okay you received regarding the
addition of a game room to.your home. The Architectural committee has
approved your request. Please keep these copies for your records and a copy
is here in the office as well.
Thank you,
i
Sylvia Corsini CCAMe
For the Board of Directors Lake La -Quints
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
James & Sheela Havas
47655 Via Montego
La Quinta, Ca 92253
Project Designer:-
'MIKE MENDOZA
P. O. BOX 692
Desert Hot Springs, Ca 92240
1-(760) 275-1816
Report Prepared by:
Santiago Lopez-Ocampo
Santiago Lopez-Ocampo
C i TY UF � Q U I N TA
P.O. Box 1018
La Quinta, Ca 92247
BUILDING & SAFETY DEPT.
760.485.8927
APPROVED
FOR CONSTRUCTION
DATE Z 7.6 Ay
1040 OW
�ECEI`V ED
Job Number:
010410 Corr. FEB 10 2010
Date: yT:
2/9/2010
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
if UF-'�F t ems...
�:
.._ `E .r,, � ..
�,
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
James & Sheela Havas
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
219/2010
Project Address
47655 Via Montego La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,269
Addition
259
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features see Part 2 of 5 Status
Slab Unheated Slab -on -Grade
None 3,010 Existing
Wall Wood Framed
R-13 2,776 Existing
Door Opaque Door
None 72 Existing
Roof Wood Framed Attic
R-19 2,693 Existing
Slab Unheated Slab -on -Grade
None 259 New
Wall Wood Framed
R-21 272 New
Roof Wood Framed Attic
R-38 259 Radiant Barrier New
FENESTRATION U- Exterior
Orientation Area Factor SHGC Overhang Sidefins Shades Status
Right (N) 100.0 0.870
0.70 none none Bug Screen
Existing
Right (N) 6.0 0.510
0.66 none none Bug Screen
Existing
Rear (NM 15.0 0.870
0.70 none none Bug Screen
Existing
Rear (W) 192.0 0.870
0.70 none none Bug Screen
Existing
Left (S) 88.0 0.870
0.70 none none Bug Screen
Existing
Front (E) 48.0 0.870
0.70 none none Bug Screen
Existing
Right (N) 30.0 0.510
0.34 none none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 78% AFUE
Split Air Conditioner 9.7 SEER Setback
Existing
1 Central Furnace 78% AFUE
Split Air Conditioner 9.7 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC System - Main Hous Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
HVAC System - Guest Hou Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
WATER HEATING
Ot . Type Gallons Min. Eff Distribution
Status
EnergyPro5.O by Ener Soft User Number: 5732
RunCode: 2010-02-09T10:51:2 ID: 010410 Corr.
Page 3 of 13
PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF -1 R
Project Name
James & Sheela Havas
Building Type 0 Single Family 0 Addition Alone
0 Multi Family 0 Existing+ Addition/Alteration
Date
2/9/2010
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The Existing Furnace Default FAU/AC 1992 - 2005 has an AFUE less than the Vintage Defaults. Field verification is required.
The Existing Air Conditioner Default FAU/AC 1992 - 2005 has an SEER less than the Vintage Defaults. Field verification is required.
HIGH MASS Design - Verify Thermal Mass: 1, 813.0 ft' Exposed Slab Floor, 3.500" thick at Main House
HIGH MASS Design - Verify Thermal Mass: 880.0 ft' Covered Slab Floor, 3.500" thick at Main House
The Existing Furnace Default FAU/AC 1992 - 2005 has an AFUE less than the Vintage Defaults. Field verification is required.
HIGH MASS Design - Verify Thermal Mass: 51.0 ft2 Exposed Slab Floor, 3.500" thick at Guest House
HIGH MASS Design - Verify Thermal Mass: 266.0 ft2 Covered Slab Floor, 3.500" thick at Guest House
HIGH MASS Design - Verify Thermal Mass: 259.0 ft2 Exposed Slab Floor, 4.000" thick at Addition
The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential
Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
Ener Pro 5.0 by Energ ySoft User Number: 5732 RunCode: 2010-02-09T10:51:2 ID: 010410 Corr. Page 4 of 13
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF-1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
James & Sheela Havas
❑ Multi Family m Existing+ Addition/Alteration
219/2010
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2 r
Space Heating 6.58 5.29 1.28
Space Cooling 165.68 162.82 2.86
Fans 34.07 33.46 0.61
Domestic Hot Water 11.16 11.16 0.00
Pumps 0.00 0.00 0.00
Totals 217.48 212.72 4.75
Percent Better Than Standard: 2.2%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 618 48
Fuel Available at Site: Natural Gas (S) 1,003 88
Raised Floor Area: - 0 (tM 598 207
Slab on Grade Area: 3,269 (N) '1,379 136
Average Ceiling Height: 10.0 Roof 2,952 0
Fenestration Average, U- Factor: 0.64 TOTAL: 479
Average SHGC: 0.68 Fenestration/CFA Ratio: 14.7%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Santiago Lopez-Ocampo ;�J 0
2/9/2010
P.O. Box 1018 Santiago to ez-Ocam
Name ame o 9 p p
City/State/ZipCity/State/Zip La Quinta, Ca 92247 Phone 760.485.8927 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other'compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company MIKE MENDOZA
Address P. O. BOX 692 ® O
Name 20
.
City/State/Zip Desert Hot Springs, Ca 92240 Phone 1-(760) 275-1816' Signed Lic (rise # Date
Ener Pro 5.0 by Ene Soft User Number. 5732 RunCode: 2010-02-09T10:51:2 /D: 010410 Corr. Page 5 of 13
19
CERTIFICATE OF COMPLIANCE: Residential
Part 4 of 5 CF -1 R
Project Name ..
James & Sheela Havas
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
2/9/2010
OPAQUE SURFACE DETAILS
Surface
Type Area
Ll- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Slab
1,813
0.730 None -
0
180 1 Existing 4.4.7-A1 Main House
Slab
880
0.730 None
0
180 Existing 4.4.7-A 1 Main House .
Wall
746
0.102 R-13
0
90 Existing4.3.1-A3 Main House
Wall
35
0.102 R-13
315
90 Existing 4.3.1-A3 Main House
Wall
356
0.102 R-13
2701
90 Existing 4.3.1-A3 Main House
Wall
35
0.102 R-13
0
-90 Existing 4.3.1-A3 Main House
Wall
715
0.102 R-13
180
90 Existing 4.3.1-A3 Main House
Wall
388
0.102 R-13
90
90 Existing 4.3.1-A3 Main House
Door
24
0.500 None
90 .
90 Existing 4.5.1-A4 Main House
Door
48
0.500 1 None
90
90 Existing 4.5.1-A4 Main House
Roof
2,693
0.049 R-19
0
18 Existing 4.2.1-A4 Main House
Slab
51
0.730 None
0
180 Existing 4.4.7-A1 Guest House
Slab
266
0.730 None
0
180 Existing 4.4.7-A 1 Guest House
Wall
191
0.102 R-13
1 01
90 1 Existin 4.3.1-A3 Guest House
Wall
200
0.102 R-13
-1 1801
90 1 Existing 4.3.1-A3 Guest House
Wall
110
0.102 R-13
1 901
90 1 Existing 4.3.1-A3 Guest House
FENESTRATION SURFACE DETAILS
ID
Type
Area LI -Factor SHGC
Azm Status
GlazingType Location/Comments
1
Window
15.0 0.870 NFRC' 0.70 NFRC'
0 Existing
2001 Build. EnergyStd Mtl-DefClr Main House
2
Window
6.0 0.870 NFRC 0.70 NFRC
0 Existing
200 1 Build. EnergyStd Mtl-DefC/ Main House
3
Window
3.0 0.510 NFRC 0.66 NFRC
0 Existin
Pittsburgh ComingGB 12x12 Main House
4
Window
3.0 0.510 NFRC 0.66 NFRC
0 Existing
Pittsburgh Corning GB 12x12 Main House
5
Window
30.0 0.870 NFRC 0.70 NFRC
0 Existing
200 1 Build. EnergyStd Mtl-DefC/ Main House
6
Window
15.0 0.870 NFRC 0.70 NFRC
315 Existing
12001Build. EnergyStd Mtl-DefClr Main House
7
Window
64.0 0.870 NFRC 0.70 NFRC
270 Existing
2001 Build. EnergyStd Mtl-DefClr Main House
8
Window
19.5 0.870 NFRC 0.70 NFRC
270 Existing,
200 1 Build. EnergyStd Mtl-DefClr Main House
9
Window
64.0 0.870 NFRC 0.70 NFRC
270 Existing -
2001 Build. EnergyStd Mtl-DefClr Main House
10
Window
19.5 0.870 NFRC 0.70 NFRC
• 270 Existing.
2001 Build. EnergyStd Mtl-DefClr Main House
11
Window
25.0 0.870 NFRC . 0.70 NFRC
270 Existing
2001 Build. EnergyStd Mtl-DefClr Main House
12
Window
15.0 0.870 NFRC 0.70 NFRC
0 Existing
2001 Build. EnergyStd Mtl-DefClr Main House
13
Window
20.0 0.870 NFRC 0.70 NFRC 180 Existing
2001Build.Energ Std Mtl-DefClr Main House
14
Window
20.0 0.870 NFRC 0.70 NFRC
180 Existing
2001 Build. EnergyStd Mti-DefClr Main House
15
Window
48.0 0.870 NFRC 0.70 NFRC
180 Existing
2001 Build. EnergyStd Mtl-DefClr Main House
16
Window
9.0 0.870 NFRC . 0.70 NFRC
0 Existing
2001 Build. EnergyStd M DefClr Guest House
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-8 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC Hat Wd
Ove hang Left Fin Right Fin
Len HqA LExt REM Dist Len H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76 -
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
.0.76
7
Bug Screen
0.76 .
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
-
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
JBug Screen
0.76
Ener Pro 5.0 by Ener Soft User Number: 5732
RunCode: 2010-02-09T10:51:2 ID: 010410 Corr. Page 6 of 13
a
- ..-- �� _ '• � _ � of s .+
CERTIFICATE OF COMPLIANCE:
Residential Part 4 of 5 CF -1 R
Project Name
James & Sheela Havas
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
2/9 2010
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
T e Area Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Slab 259 0.730 None
01 180 1 New 4.4.7-A1 Addition
Wall 138 0.069 R-21
0 90 New 4.3.1-A6 Addition
Wall 133 0.069 R-21
0 90 New 4.3.1-A6 Addition
Roof 259 0.025 R-38
0 0 New 4.2.1-A21 Addition
FENESTRATION SURFACE DETAILS
ID Type Area U -Factor SHGC2
Azm Status Glazing Type Location/Comments
17 Window 48.0 0.870 NFRC 0.70 1 NFRC
90 Existing 2001 Build. EnergyStd Mtl-DefClr Guest House
18 Window 25.0 0.870 NFRC 0.70 NFRC
0 Existing 2001 Build. EnergyStd Mtl-DefClr Addition
19 Window 15.0 0.510 NFRC 0.34 NFRC
0 New General Aluminum Company Addition
20 Window 15.0 0.510 NFRC 0.34 NFRC
0 New General Aluminum Company Addition
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window
ID Exterior Shade Type SHGC H t Wd
Ove hang Left Fin Right Fin
Len Hclt LExt RExt Dist Len H t Dist Len I H t
17 Bug Screen 0.76
18 Bug Screen 0.76
19 Bug Screen 0.76
20 Bug Screen 0.76
Ener Pro 5.0 by Ener Soft User Number: 5732
Run Code: 2010-02-09T10:51:2 ID: 010410 Con-. Pae 7 of 13
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5)
CF -1 R
Project Name
James & Sheela Havas
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
2/9/2010
BUILDING ZONE INFORMATION
System Name
Zone Name
Floor Area ff
New Existinq Altered Removed Volume Year Built
HVAC System - Main House Main House
2,693
26,930 2000
HVAC System - Guest House
Guest House
317
3,170 1998
Addition
259
2,590
i Totals 2591 3,010 0 0
HVAC SYSTEMS
System Name Qty. Heating Ty 'e
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC System - Main House 1 Central Furnace;
78% AFUE Split Air Conditioner 9.7 SEER Setback
Existing
HVAC System - Guest House
1 Central Furnace
78% AFUE Split Air Conditioner 9.7 SEER Setback
Existing
1
i
I
HVAC DISTRIBUTION
System Name
Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
HVAC System - Main House
Ducted ;
Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
HVAC System - Guest House
Ducted
Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
I
❑
i
❑
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
Kitchen Pipe Ins
40,000
50
0.58
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
E
w
Hot Water Piping Length
, ft
Q c
—I
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Q HP
j
Plenum
Outside Buried
❑
❑
❑
❑
❑
❑
Ener Pro 5.0 by Ener Soft
User Number: 5732
RunCode: 2010-02-09T10:51:2 ID: 010410 Con.
Page 8 of 13
MANDATORY MEASURES SUMMARY: Residential- Pae 1 of 3 MF -1 R,
Project Name
Date
James & Sheela Havas
2/9/2010,
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in' the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures: 4" I
116(a)l: Doors and windows between conditioned and unconditioned s aces are manufactured to limit air leakage
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U=Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the Ye uirements of 10-111 a
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1.R Form.
*§150(a): Minimum R-19 insulation in wood-frameceilin orequivalent U -factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed desi n labeled R -Value.
*§150(c): Minimum R-13 insulation in wood-framelwall orequivalent LI -factor.,
150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor."
150 f : Air retarding wrap is tested labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no areater than 2.0perm/inch and shall beprotected rotected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket,.when that indoor air is vented to the
outside of the building, are prohibited. 1
Space Conditioning, Water Heating and Plumbing System Measures: '
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§1 13(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflowprevention; pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than .150 Btu/hr are exempt), and pool and
spa heaters. I
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internalinsulation where the internal insulation R -value is indicated on the exterior. of the
tank. I '
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per, Standards Table 150-13. _-
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A. It I
150(j)3A: Insulation is protected from damage, in1cludinthat due to sunlight, moisture equipment maintenance and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space. k '`
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. '
Registration Number: Registration Date/Time: HERS Provider:
EnergyPro 5.0 by EnergySoft User Number: 5732 RunCode: 2010-02-09T751:25 ID: 010410 Co, Page 9 of 13
r
MANDATORY MEASURES SUMMARY.: Residential _ ' (Page 2 of 3 MF -1 R
Project Name
Date
James & Sheela Havas
2/9/2010
§150(m)l : All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181A, or UL 1181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is .
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed -
sheet metal, duct board or flexible duct shall not be used for conveying •conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
§150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers. I -
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores. '
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard. l
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on=off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot libht.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat , pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
ro rammed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 .
Residential Lighting Measures: I
§150(k)l : High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy.luminaire asspecified by §150(k)2.
§150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated .13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz. II r '
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket. .1 1 '
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.'
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet; and utility rooms are high efficacy and controlled by a
manual -on occupant sensor. j
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet. 4
-
Registration
Re istration Number: r Registration Date/Time: HERS Provider:
EnergyPro 5.0 by EnergySoft User Number: 5732 RunCode: 2010-02-09710:51:25 ID: 010410 Con-. Page 10 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
James & Sheela Havas
2/9/2010
§150(k)11: Permanently installed luminaires locatedl in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceili6gs shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when testi d in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housingand ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exception to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is'automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five wafts of power as determined accoAng to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
1
(
I
t
f
Registration Number: Registration Date/Time: HERS Provider:
Ener Pro 5.0 by Ener Soft User Number: 5732 RunCode: 2010-02-09T10:51:25 ID: 010410 Corr. Pae 11 of 13
HVAC SYSTEM HEATING AND
COOLING LOADS SUMMARY
Project Name
James & Sheela Havas
l
Date
2/9/2010
System Name
HVAC System - Main House
Floor Area
2,693
ENGINEERING CHECKS
SYSTEM
LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 2,097
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation f7 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 0
46,860
2,703 1,110
38,982
Total Output Btuh 0
0
Output Btuh/s tt 0.0
5,224
3,393
Cooling System
0
0
Output per System 1
0
0 0
0
Total Output Btuh 1
0
2,703
0
Total Output ons 0.0
5,224
3,393
Total Output Btuh/s ft 0.0
Total Output s ft/Ton 32,316,000.0
57,307
45,768
Air System
CFM perSystem'
'0
HVAC1EQUIPMENT
SELECTION
Airflow cfm
0
Default FAU/AC 1992 - 2005
1 0
0
Airflow cfm/s ft 0.00
Airflow cfm/Ton 0.0
I
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
I TIME OF SYSTEM PEAK
1 0 1 0
Aug 3 PM I Jan 1 AM
Outside Air cfm/s tt 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF
Outside Air
0 cfm
68 OF
68 OF 105 OF
f
t
Heating Coil !
I
103 OF
... _ .......... _... . ...... ..
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air Ar
0 cfm
80/63°F
80/64°F 55/54°F
Cooling Coil
I
F.E.- 4
{
57 / 54 OF
43.1 % ROOM
ROOM
78/63°F
EnergyPro 5.0 by EnergySoft
User Number: 5732 RunCode: 2010-02-09710:51:25
ID: 010410 Corr. Pege 12 of 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
James & Sheela Havas
Date
2/9/2010
System Name
HVAC System - Guest House
1
Floor Area
576
ENGINEERING CHECKS
SYSTEM
LOAD
Number of Systems
1
I COIL
CFM
Total Room Loads 628
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
Sensible
14,031
0
1,346
0
0
0
1,346
1 16,724
PEAK COIL HTG.
PEAK
Heating System
Latent CFM
Sensible
Output perSystem 0
1,007 249
8,761
Total Output Btuh 0
Output Btuh/s tt 0.0
763
Cooling System
0
Output perSystem 1
0 0
0
Total Output Btuh 1
1,007
0
Total Output ons 0.0
763
Total Output Btuh/s tt 0.0
Total Output s ftfTon 6,912,000.0
10,286
Air System
CFM perSystem
0
HVACIEQUIPMENT
SELECTION
Airflow cfm
0
Default FAU/AC 1992 - 2005
1 0
0
Airflow cfm/s ft
0.00
Airflow cfm/Ton
0.0
Total Adjusted System Output
(Adjusted for Peak Design conditions)
! TIME OF SYSTEM PEAK
1 0 0
Aug 3 PM Jan 1 AM
Outside Air °i° 0.0%
Outside Air cfm/s tt 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF
Outside Air
0 cfm
68 OF
1
68 OF 105 OF,
Heating Coil ,
I
Ll1
f _
103 OF
ROOM -
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling
Peak
112/78°F
Outside Air
0 cfm
80/64°F
I ,
80/64°F 55/54°F
f
Cooling Coil
I
57 / 55 OF
44.7% ROOM Y .
78/63°F
EnergyPro 5.0 by EnergySoft
User Number: 5732 RunCode: 2010-02-09T10:51:25