BSOL2014-002778-495 CALLE TAMPICO
LA QUINTA, CALIFOR�IiA 92253
Application Number:
Property Address:
APN:
Application Description
Property Zoning:
Application Valuation:
Applicant:
SCC SOLAR ENERGY
1040 S. MT. VERNON
COLTON, CA 92324
4
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
BSOL2014-0027
47600 VIA MONTESSA
643120006
6.89 kW PV SYSTEM - (26) 265W PANELS W/ M250 MICROINV/1 SUB
$15,000.00
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: License No.:
D�te: l I - 17 L` ContractgeQ A� h tkyl �,Y..
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
( ) 1, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
( ) 1, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:—
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
11/17/2014
17 2014
_ECO MMUNITY DEVELOPMENT DEPARTMENT
Contractor:
SCC SOLAR ENERGY
1040 S. MT. YERNON
COLTON, CA 92324
Llc. No.:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Sectior 3700 of the Labor Code, for the performance
of the work for which this permit is issue J.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation ins rance carrier and policy number are:
Carrier: Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comp) with those provisions. p � y� �, � p�
D t3 e: 7 — -41 App li nt: C7 t5 t}' -L � l z �`L�'
WARNING: FAILURE TO SECURE WORKEtS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT AZKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf thio application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission relat =d to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of thie. application becomes null and void if work is
not commenced within 180 days from rote of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize rep esentatives of this city to enter upon the above-
mentioned property for inspection purposes.
Date: / ( 7 ' / Signature (Arplicant or Age :ZICJ(iC°�C d u7\
DESCRIPTION
FINANCIAL .•
'ACCOUNT
1,
QTY AMOUNT
PAID`
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$1.00
11/17/14
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
SCC SOLAR ENERGY
CHECK
MR139
1205
MFA
Total Paid forBUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PV SYSTEM - ARRAY, FIRST 20
101-0000-42403
0
$24.17
$24.17
11/17/14
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
SCC SOLAR ENERGY
CHECK
MR139
1205
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PV SYSTEM - ARRAY, FIRST 20 PC
101-0000-42600
0
$24.17
$24.17
11/17/14
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
SCC SOLAR ENERGY
CHECK
MR139
1205
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PV SYSTEM - MISC EQUIPMENT
101-0000-42403
0
$24.17
$24.17
11/17/14
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
SCC SOLAR ENERGY
CHECK
MR139
1205
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PV SYSTEM - MISC EQUIPMENT PC
101-0000-42600
0
$24.17
$24.17
11/17/14
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
SCC SOLAR ENERGY
CHECK
MR139
1205
MFA
Total Paid forELECTRICAL: $96.68 $96.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT =
PAID
PAID DATE
PERMIT ISSUANCE
101-0000-42404
0
$91.85
$91.85
11/17/14
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
SCC SOLAR ENERGY
CHECK
MR139
1205
MFA
Total Paid forPERMIT ISSUANCE: $91.85 $91.85
• a
Description: 6.89 kW PV SYSTEM - (26) 265W PANELS W/ M250 MICROINV/1 SUB
Type: SOLAR Subtype: Status: APPROVED
Applied: 10/13/2014 KHE
Approved: 11/12/2014 JFU
Parcel No: 643120006 Site Address: 47600 VIA MONTESSA LA QUINTA,CA 92253
Subdivision: TR 26152 Block: Lot: 234
Issued:
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $15,000.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
COMPLETION DATE
Details: 6.89 kW PV SYSYTEM - (26) SUNEDISON F265Kyc MODULES W/ENPHASE M250-60-2LL-S2X MICROINVERTERS AND 175A SUBPANEL
[390SF] 2013 CALIFORNIA ELECTRICAL CODE
ADDITIONAL
CHRONOLOGY
_ TYPE
' CHkONCiI.OGY
___. ,.... STAFF NAME.,.......
_ ,......
ACTION DATE.
COMPLETION DATE
� NOTES
E-MAIL
JAKE FUSON
10/28/2014
10/28/2014
Emailed correction list and redlined plans to applicant.
E-MAIL
JAKE FUSON
11/5/2014
11/5/2014
EMAILED 2ND REVIEW CORRECTION LIST TO SCC SOLAR
ENERGY AT sccsolarenergy@gmail.com.
PLAN CHECK SUBMITTAL
KAY HENSEL
10/13/2014
10/13/2014
RECEIVED
CALLED BREANNE FROM SCC SOLAR, READY FOR
TELEPHONE CALL
JAKE FUSON
10/28/2014
10/28/2014
CORRECTIONS.
CALLED BREANNE WITH SCC SOLAR ENERGY TO NOTIFY HER
PLANS WERE APPROVED AND PERMIT READY TO ISSUE.
TELEPHONE CALL
JAKE FUSON
11/12/2014
11/12/2014
NOTIFIED HER THAT (3) HARD COPIES OF APPROVED PLANS
WERE REQUIRED TO BE STAMPED AND SIGNED BY REVIEWER
IN ORDER FOR PERMIT TO BE ISSUED.
CONDITIONS
Printed: Monday, November 17, 2014 10:46:09 AM 1 of 3 CJsrsTrMs
INSPECTIONS
CONTACTS
RESULT REMARKS NOTES_
NAME TYPE
NAME ADDRESSI CITY STATE ZIP PHONE
FAX EMAIL
APPLICANT
SCC SOLAR ENERGY 1040 S. MT. VERNON COLTON CA 92324
CONTRACTOR
SCC SOLAR ENERGY 1040 S. MT. VERNON COLTON CA 92324
OWNER
PAUL DYBEDAL 92253
INSPECTIONS
SEQI,D " INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED
DATE DATE
RESULT REMARKS NOTES_
SOLAR FINAL"
DESCRIPTION
ACCOUNT. QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
7CLTD'
BSAS SB1473 FEE
101-0000-20306 0
$1.00
$1.00
11/17/14
MR139
1205
CHECK
SCC SOLAR ENERGY
MFA
Total Paid for BUILDING STANDARDS ADMINISTRATION
$1.00
$1.00
BSA:
PV SYSTEM -ARRAY,
101-0000-42403
0
$24.17
$24.17
11/17/14
MR139
1205
CHECK
SCC SOLAR ENERGY
MFA
FIRST 20
PV SYSTEM - ARRAY,
101-0000-42600
0
$24.17
$24.17
11/17/14
MR139
1205
CHECK
SCC SOLAR ENERGY
MFA
FIRST 20 PC
PV SYSTEM - MISC
101-0000-42403
0
$24.17
$24.17
11/17/14
MR139
1205
CHECK
SCC SOLAR ENERGY
MFA
EQUIPMENT
PV SYSTEM - MISC
101-0000-42600
0
$24.17
$24.17
11/17/14
MR139
1205
CHECK
SCC SOLAR ENERGY
MFA
EQUIPMENT PC
Total Paid for ELECTRICAL:
$96.68
$96.68
PERMIT ISSUANCE
101-0000-42404
1. 0
$91.85
$91.85
11/17/14
MR139
1205
CHECK
SCC SOLAR ENERGY
MFA
Total Paid for PERMIT ISSUANCE:
$91.85
$91.85
•
INSPECTIONS
SEQI,D " INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED
DATE DATE
RESULT REMARKS NOTES_
SOLAR FINAL"
Printed: Monday, November 17, 2014 10:46:09 AM 2 of 3
S YS7Eti1S
REVIEW TYPE
ATTACHMENTS
REVIEWER
SENT DATE
DUE DATE
RETURNED
DATE
REVIEWS
STATUS
REMARKS
NOTES
NON-STRUCTURAL
AJ ORTEGA
10/13/2014
10/20/2014
10/28/2014
REVISIONS REQUIRED
0
NON-STRUCTURAL
JAKE FUSON
11/4/2014
11/11/2014
11/5/2014
REVISIONS REQUIRED
DOC
SEE ATTACHED CORRECTION LIST.
NON-STRUCTURAL
JAKE FUSON
11/12/2014
11/19/2014
11/12/2014
APPROVED
Printed: Monday, November 17, 2014 10:46:09 AM 3 of 3 c
S YS7f MS
ATTACHMENTS
„ Allacl6letu Type
VP
� �
CREATED ,....,- ,
OWNER ':.., .
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC,
10/28/2014
JAKE FUSON
SOLAR 1ST REVIEW
SOLAR 1ST REVIEW
0
COMMENTS.pdf
COMMENTS.pdf
DOC
10/28/2014
JAKE FUSON
SOLAR 1ST REVIEW
SOLAR 1ST REVIEW
0
REDLINES.pdf
REDLINES.pdf
Printed: Monday, November 17, 2014 10:46:09 AM 3 of 3 c
S YS7f MS
Tar 4 4a�rw
COMMUNITY DEVELOPMENT DEPARTMENT
78-495 CALLS TAMPICO
LA QUINTA, CALIFORNIA 92253
(760) 777-7125 FAX (760) 777-7o I I
RESIDENTIAL PLAN CHECK CORRECTION LIST (SOLAR)
DATE'- 10/28/2014
STATUS: FIRST REVIEW
PLAN CHECKED BY: JAKE FUSON
TELEPHONE NUMBER: (760) 777-7081
ADDRESS: 47-600 Montessa
DESCRIPTION: PV SOLAR SYSTEM
APPLICANT: SCC SOLAR ENERGY
PLAN CHECK #: BSOL2014-0027
This submittal has been checked for compliance with the 2013 California BLilding Codes
City
and the of La Quinta Municipal Code.
APPLICANT: BUILDING DEPARTMENT STAFF:
The following items are being returned to for DO
you NOT accept any resubmittal unless ALL of the
correction: following items are included:
I- SOLAR (REDLINED) PLAN 1- SOLAR (REDLINED) P__ -AN
2- UNMARKED PLAN SET I- CORRECTION LIST w/responses
1- CORRECTION LIST 2- REVISED PLAN SETS
1- ASSESSORS SITE/FLOOR PLAN
1
INSTRUCTIONS TO APPLICANT: V)
I ) Provide a written response to each comment on the following pages, noting specifically where the correction
can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not
acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses
such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your bac-IC check.
2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or
Calculations as necessary.
3) Return all red -marked Plans and/or Calculations with your resubmittal.
4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name End telephone number
and shall be wet -signed by the preparer. If the preparef is a licensed architect or engineer, all documents
prepared.by that licensed individual shall also bear his/her stamp as prescribed by CalifDmia Business and
Professions Code Section 5536. Resubmittals will not be accepted with signatures missing.
5) Return this list, your written responses, and all documents listed above with your resubmittal.
Residential Plan Check Correction List (SOLAR) Page 1 of 3
0—
SECTION A - GENERAL
Provide a Assessor's Parcel Number (APN) of site of proposed work.
2� Note on Plans: "All construction shall comply with the 2013 California Building, Residential, Mechanical, .
Electrical, Plumbing, Energy, and Green Building Codes and the La Quinta Municipal Code." Remove notes
referencing other Codes.
SECTION B — SOLAR
I. General
1) Reconcile noted information shown on single line diagram. See V review redlined plan. Please provide a
response for each item, either on returned redlined plan or in letter.
Z, Note on Plans: "Photovoltaic system conductors shall be: identified and grouped. The means of identification
shall be permitted by separate color coding, marking tape; tagging, or other approved means. The means of
grouping shall be wire ties or similar means at least once, and then at intervals not to exceed six (6) feet."
(CEC §690.4(B))
1�0Note on Plans: `Photovoltaic equipment and systems and all associated wiring and interconnections shall be
installed only by qualified persons." (CEC §690.4(E))
II. Circuit Requirements
Overcurrent devices shall be sized to carry not less than 1.25% of the maximum currents as calculated in
690.8(A). (CEC §690.8(8)( )) Provide conductor sizing schedule to jus m ro sed con
y p Po ductors.
�?) Circuit conductors shall be sized to carry the large of 125% of the maximum currents calculated in 690.8(A)
without any additional correction factors for conditions of use or 100% of the maximum current after
conditions of use have been applied. (CEC §690.8(B)(1)), Please see above correction for required
information to be shown on plan. Clarify whether proposed strings are combined at junction box or
not, amount of conductors at AC.1 exceeds typical single string but 40A OCPD at service looks like
single string.
Photovoltaic source circuit, photovoltaic output circuit, inverter output circuit, and storage battery circuit
conductors and equipment shall be protected in accordance with the requirements of Article 240. Circuits
connected to more than one electrical source shall have overcurrent devices located so as to provide
overcurrent protection from all sources. (CEC §690.9(A)) Overcurrent protection not being provided for
micro -inverter engage cable being combined at junction box. Clarify with above comments.
III. Disconnecting Means
1) No corrections apply
IV. Wiring Methods
`Yf All raceway and cable wiring methods included in the California Electrical Code and other wiring systems
and fittings specifically intended and identified for use on photovoltaic arrays shall be permitted. Provide a
conductor sizing table, including conduit sizing, to justify the proposed installation. (CEC §690.31, Chapter 3
Residential Plan Check Correction List (SOLAR)
Page 2 of 3
44
City df La Quinta
'14 Where the number of current -carrying conductors in a raceway exceed three (3). the allowable ampacity of
each conductor shall be reduced as shown in Table 310.15(B)(2)(a). (CEC §319).15(B)(2)) Adjust
accordingly.
�) Conduits exposed to sunlight on rooftops, where conductors or cables are installed, the adjustments shown in
Table 310.15(B)(2)(c) shall be added to the outdoor temperature to determine the applicable ambient
temperature for application of the correction factors in Table 310.16. (CEC §310.15(B)(2)(c)) Adjust
conductor sizes accordingly.
V. Grounding
1) No corrections apply.
VI. Marking, Connection to Other Sources, Storage Batteries and Systems Over 600 Volts
�) Provide schedule with the location of all required markings and labels .for the proposed photovoltaic system.
(CEC §690) Please update signage sheet per 2013 California Electrical Code requirements. Specifically
69056(B)/705.10 — SERVICE and 705.12(D)(7) — PANELBOARD.
SECTION C - FIRE'
1) No corrections apply.
SECTION D - STRUCTURAL
OV
���"
l) Provide site specific structural calculations for rack support spacing exceeding 48" on center. .
SECTION E - MISCELLANEOUS COMMENTS
1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise
Plans as necessary and provide written response, noting where correction can be found.
2) Provide one copy each of the Site Plan and Floor Plan for. the County Assessor's office. While not required
for resubmittal, this administrative item must be addressed prior to issuance of building permit.
END CORRECTION LIST
As further information is provided and reviewed, additional corrections may be required.
Residential Plan Check Correction List
Page 3 of 3
Bin #
Permit # ��
Submittal
City of La � QUir rr
nta
Building 8i Safety Division
P.O. Box 1504,78-495 Calle Tampico.
La Quinta, CA 92253 - (760) 777 -7012 -
Building Permit Application and Tracking Sheet
Project Address:
v f �^�e
Owncr's Name. AL -L V eC 1. I
A. P. Number:
Plan Sets
Address: 4 /, 4e00 V) P Q 9 T A
Legal Description:
Plan Check submitted
City, ST, Zip:
Contractor: S'C � � _ � r �
Telephone/— .S.S-- y — 7=
Address: I L--3L��
S'-� 00�8S
Project Description:
City, ST, Zip: (2_0
IT,0 rV C 211J 312 14
C ^A r7 b Q, I/(' I
Telephone:
:
_ `�
- d r. �C.
�S -
State Lic. # : �� (� '
Arch., Engr., Designer:
3 � CityLic.: #,.:::
Plan Check Balance.
Address:
(�
Title 24 Cala.
City., ST, Zi
Plans picked up
fele hone:
P
Construction
Construction Type: Occupancy:
'talc Lie.
ProJect hPc (circle ]a ne • New Add'n Flter Repair r Demo
0
lame of Contact Person: Qdq- X93_ X1444
Sq. Ft_:
#Stories:
[ cicphone # of Contact Person: R,AN NE
Estimated Value of Project: f�
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Rcq'd
Rcc'd
TRACKING
PERMIT FEES.
Plan Sets
3
Plan Check submitted
Item
Amount
Structural Calcs.
Reviv%ved, ready for corrections
IQ g
Ian Clicck Dcposit
Truss Cala.
Called Contact Person
Plan Check Balance.
Title 24 Cala.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2"' Rcview, ready for eorrectionsiiw
Electrical
Subcontactor List
Called Contact Person C;MA'/C.
11/5
Plumbing
Grant Decd
Plans picked up
S.M.T.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Review, ready for correctio i<ssuc
l V12-
Developer ImpactFee
Planning Approval
Called Contact Person
�2
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fccs
Total Permit Fees