Loading...
BRES2015-003478-495 CALLE TAMPICO LA QUINTA, CALIFORNIA Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: Applicant: SUNROSE CORPORATION 72-850 SOMERA ROAD PALM DESERT, CA 92260 COMMUNITY DEVELOPMENT DE BUILDING PERMIT BRES2015-0034 80605 VIA MONTECITO . 777400012 SUNROSE CORP/SUNROSE CORP/HIDEAWAY/SFD 6692SQ FT $637,719.20 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 533670 Dat Contra "r. I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: I ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The, Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). I ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (� I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY .I hereby affirm under penalty of perjurythat there is a construction lending agency for the performance of the -work for which this permit is issued (Sec. 3097, Civ. C.). Lender's N Lender's Address: coMMu `� I r UI -LA QUJN7A� NI1p pMENTD Owner: R'AF ENT 10E AND BETH GIORDANO 40.101 MONTEREY AVE. #131-214 RANCHO MIRAGE, CA Contractor: SUNROSE CORPORATION 72-850 SOMERA ROAD PALM DESERT, CA 92260 (760)773-6633 Llc. No.: 533670 (760)777-7125 (760)777-7011 (760)777-7153 4/10/2015 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided.for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by S eWu 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Polity Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the La or Code, I shall forthwith comply with those provisions. ate: 7 / ApI ca � WARNING: FAILURE TO SECURE WORKERS' C MPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose . request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null 'and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this.application and state that the above information is correct. , I agree to comply with all city and county ordinances and state laws rela to building construction, and hereby authorize representatives of this city to enter,Epont e above- mentioned property for inspection purposes. Date: /�" 7 Signature (Applicant or A FINANCIAL INFORMATION F,r§�r a; DESCRIRTION �. �s. QN.... AMOUNT+€� PAID;D'ATE' .. ..._...A000UNT.::E .�' ,> EPAIDu,B` ART IN PUBLIC PLACES - RESIDENTIAL .270'-0000-43201 0 $1,094.30 $1,094.30 4/10/15 < BYa' ¢ METHOD s RECEIPT #r a CHECK # ` ICLTD BY xPAID _ rN,;? r > , SUNROSE CORPORATION CHECK R4948 16917 MFA Total Paid forART IN PUBLIC PLACES - AIPP: $1,094.30 $1,094.30 :DESCRIPTION •t* ` �� :"ACCOUNT ? F QTY AMOUNT PAID PAID DATE _., § ' ;° ro' ;1 BSAS SB1473 FEE 101-0000-20306 0 $26.00, $26.00 4/10/15 `PAID, BY � � *'� METHOD x ` �; RECEIPT # CHECK #�, CLTD BY ` .,•' r, SUNROSE CORPORATION CHECK :, R4948 16917 MFA Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $26.00 $26.00 >' •3DESCRIPTION Fx` 3ACCOUNT' ` :QTY,�AMOIINT �,z ` a = a< PAID �PAIDDATEt �� DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $942.00 4/10/15 r ° ` PAID BY ¢ckt.t_az. b =c . ; x d METHOD = ' c z % a RECEIPT #� X «e t CHECK # CLTD r SUNROSE CORPORATION CHECK R4948 16917 MFA ,DESCRIPTION f QTY 'AMOUNTS <:: PAID °PAIDDATE ,ACC , ' DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 $129.00 4/10/15 PAID'BY METHOO� ° :: ` ' RECEIPT # '*r CHECK # r', CLTD BY i t'� SUNROSE CORPORATION CHECK R4948 16917 MFA S 4 ' DESCRIPTION ' " A $>r 'Kt A000UNT ra QTY AIV £PAID `$ �, x yak ,^ s , w APAID`DATE DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $433.00 4/10/15 PAID.SY n r METHOD } v RECEIPT # ` ` s CHECK # CLTD BY r �., SUNROSE CORPORATION CHECK R4948 16917 MFA `DESCRIPTION ACCOUNT QTY ;� F {" PAID ` `PAID DATE , . >� yAMOUNTr DIF - LIBRARIES 253-000033200 0 $344.00 $344.00 4/10/15 PAID BY . 4f METHOD :� !RECEIPT # x CHECK #s ` R CLTD BYi �, A11. SUNROSE CORPORATION CHECK R4948 16917 MFA DESCRIPTION t { €m` ` ACCOUNT` QTYk4AMOUNT r S PAIDs - §PAID:DATf DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 $40.00 4/10/15 - METHOD r REC# '. CHECK # CLTD BY r ." ,.. w Y P,, x •, .. , ,. or ,'R a , ti,. SUNROSE CORPORATION CHECK R4948 • 16917 MFA " ;� DESCRIPTION . ACCOUNT' ,iQTY AMOUNT :y PAID ' "' PAID DATE , ., DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $2,048.00 4/10/15 fs ''' PAID`:BY ` :' }:..METHOD CHECK # �• CLTD BY Y• SUNROSE CORPORATION CHECK R4948 16917 MFA rt DESCRIPTION' u 4„g ACCOUNT fix, 4: Tlf Q AMOUNT PAID , PAI Q DATE . DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00. $116.00 4/10/15 i PAID. BY + 'a RECEIPT # # > `' CLTD BY ; �� .,�� yMETHOD ,CHECK SUNROSE CORPORATION CHECK R4948 16917 MFA •, ;;QTY AMOUNT : r =: PAID<t PAID DATE =DESCRIPTION ,.;A000UNT DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $2,842,00 4/10/15 PAID; BY veq f' ar METHOD RECEIPT# `€ CHECK# "'CLTD BY. SUNROSE CORPORATION CHECK R4948 16917: MFA Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 $6,894.00 DESCitIPTION n' _ ACCOUNT yQTY AMOUNT ` 3 PAID PAID' DATE - f' TEMP POWER SERVICE 101-0000-42403 0 $24.17. $24.17, 4/10/15 r ° 'PAID. BY " ' METHOD mRECEIPTCHECK # <' CLTD BY .y� „. € . SUNROSE CORPORATION CHECK R4948 16917 MFA ;'DESCRIPTIONS>> 'ACCOUNT t QTY AMOUNTS`r PAID ti%{ `PAID DATE .w t :' TEMP POWER SERVICE PC 101-0000-42403 0 $16.92 $16.92 4/10/15 x RECEIPT #v CHECK # x a CLTD BY ,PAID,BY . aMETHOD' �.. ..e x SUNROSE CORPORATION CHECK R4948 16917 MFA Total Paid for ELECTRICAL: $41.09 $41.09 ;DESCRIPTIONACCOUNT#d QTY AMOUNT PAID PAID DATE'. 7 ,z RESIDENTIAL; EA ADDITION 1,000SF 101-0000-42403 0 $98.64 $98.64 4/10/15 ;zy'y�t x PAID,BY ' az r i METHOD'` RECEIPT#� BY E- ,CHECK#rCLTD SUNROSE CORPORATION CHECK R4948 16917 MFA '° �x<DESCRIPTION : w 'ACCOUNT��"� �f QTY '� Q M >krAMOUNT u'6 € "� PAID PAID DATE` yV. z,r €..., t , RESIDENTIAL, EA ADDITION 1,000SF, PC '101-0000-42600 0 $40.64 $40.64 4/10/15 PAIDtBY F' c: gk METHODSr° € RECEIPT # f T., # CLTD BY .. , ,CHECK SUNROSE CORPORATION CHECK R4948' 16917 MFA ¢ t . s'> DESCRIPTIONS .k`ACCOUNT QTI( ` smi PAID * rPAID'DATE �� a k ,y ,y I`AMOUNT ,: RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 '$145.03 4/10/15 b r•Gak€y :abs *�. t PAID'BY ', +W *c ,; 3 METHOD 'ay a r = rRECEIPT # r :.. CHECK #,,, , CLTO'BY r �.r>; z ; r SUNROSE CORPORATION CHECK R4948 16917 MFA tl)ESCRIPTION ` ACCOUNT QTY I 'PAID . a? y St E r RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $47.86 4/10/15 5 PAID BY METHOD CHECK# CLTD-BY::'. r 1v;::.,_;1­ ,RECEIPT#,:` € SUNROSE CORPORATION • CHECK R4948 16917 MFA Total Paid for ELECTRICAL - NEW CONSTRUCTION: $332.17 $332.17 F4 x };aDESCRIPTION +«z it ACCOUNT, ”, QTY x: AMOUNT ` PAID 1.:PAID-DATE- PAID DATE t„x•=3 f -J,.: RESIDENTIAL RESIDENTIAL FINISH GRADING PC 101-0000-42600 0 $143.00 $143.00 4/10/15 =ia PAID BY ' t ` METHOD _� RECEIP#:�"CHECK a J17-' CLTD BY ,x ..� a _,T SUNROSE CORPORATION CHECK R4948 16917 MFA Total Paid forGRADING: �° - $143.00 ! $143.00 ' ,, ' ' f bESCRIPTION ; r ", ACCOUNT s`, t QTY AMOUNTa PAID' PAID DATE • CONDENSER/COMPRESSOR 101-0000-42402 0 $217.56 $217.56 4/10/15 ' PAID BY -,_ ' ' ` METk10D r ' € RECEIPT # E "'' CHECK # F, x^CLTD BY c rc SUNROSE CORPORATION CHECK R4948 16917 MFA ESCRIPTION s=u -g ACCOUNT ° �" r `QTY =AMOUNT_ €:- uxPAID 'PAID DATE r F CONDENSER/COMPRESSOR PC 101-0000-42600 0 $145.02 $145.02 4/10/15 :,PAIDtBY METHOD "!RECEIPT: # CHECK # "; CLTD BY x , F SUNROSE CORPORATION CHECK R4948 16917 MFA " c `DESCdtIPTION `'- `ar , 1, `'ACCOUNT { QTY 7 > AMOUNTr fes' PAID s r PAID DATE r x ., ;� $ EXHAUST HOOD 101-0000-42402 0 $24.18 $24.18 4/10/15 ' ' a 'PAID'BY METHOD�� RECEIPT #1�` ° "Y CHECK # 3 `? CLTD BY SUNROSE CORPORATION CHECK R4948 . 16917 MFA a f)ESCRIPTION' ACCOUNT ': �} ' QTY �." 3 AMOUNT Z.$ PAID PAID:DATE g < EXHAUST HOOD PC 101-0000-42600 0 $9.66 $9.66 4/10/15 r PAID BY-. METHOD " � RECEIPT #' CHECK # CLTD BX,; ;` a Via" i -� �� SUNROSE CORPORATION CHECK R4948 16917 MFA 01 trt T;I vritk ;< PAID PAID-..* DA.,T EDESCRIPT _ . FURNACE 101-0000-42402 0 $217.56 $217.56 4/10/15 PAID:BY s ': t b :METHOD.. sz RECEIPT441, CHECK # CLTD BY ` , .. ` _.. .,, r ;4< . ,.:.: SUNROSE CORPORATION CHECK R4948 16917 MFA } t ACCOUN TY LINT ,. �PAIDRIPTION r PAID DATE s.. _ ry z FURNACE PC 101-0000-42600 0 .$145.02 $145.02 4/10/15 PAIDZY '} �� I �' x� °' - RECEIPT # � CHECK #n `' CLTD BY''_ g " }METHOD r,. ,. , _' , SUNROSE CORPORATION 'CHECK R4948 16917 MFA tr'`.OESCRIP.TION t ACCOUNT AMOUNT PAIDi� 'PAID DATE ,_, ,. - _ , < 4^. :QTY' .... r' VENT FAN 101-0000-42402 0 $84.63 $84.63 4/10/15 PAID BYMETHOD "� vo RECEIPT#6` rz CHECK CLTD BY,'' s k . SUNROSE CORPORATION CHECK •R4948 16917 MFA 'r DESCRiPT10N <' �.' >e1 "ACCOUNT { i � QTY � AMOUNT F PAID PAIf)DATE �5 �• VENT FAN PC 101-0000-42600 0 $33:81 $33.81 4/10/15 PAID ;' `Y µ ,,` zrFMET1OD > � � aRECEIPT # : CHECK # ' x CiTO BY yBY � x w � . , SUNROSE CORPORATION CHECK ,R4948 16917 MFA x DESCRIPTION f t ACCOUNT` QTY AMOUNT PAIDs PAID DATE ���+ Via. �. WALL HEATER 101-0000-42402 0 $74.13 $74.13 4/10/15 R PAID.BY rg ` RECEIPT #k r4* `rCHEGK #ter CLTD BY '� SUNROSE CORPORATION CHECK 'R4948 16917 MFA DESCRIPTION' H e e tACCOUNTE, ;;. € : QTYR� $ AMOUNTS; %` h z PAID PAID DATE. n WALL HEATER PC 101-0000-42600 0 $36.27' $36.27 4/10/15 PAID. BY' �`' } �r h : �s a METHOD x „ c ::RECEIPT # CHECK # CLTD BY-.': '04= xr .-.gc SUNROSE CORPORATION. CHECK R4948 16917 MFA Total Paid for MECHANICAL: $987.84 $987.84 ` , M:DESCRIPTIOfV '- ; F t aACCOUNTr ;` QTY AMOUNT '' PAID f, :I jPAID_DATE . a NEW CONSTRUCTION PERMIT 101-0000-42400 0 .$826.85 $826.85 4/10/15 ' PAID BY �,`:' r'' METHOD+` + t� :`RECEIP,T# e- F CHECK #"k •CLTD BY: .. •3- ii .• x .: ., d -. :e F 'CT i..♦ SUNROSE CORPORATION CHECK R4948 16917 MFA Total Paid for NEW CONSTRUCTION-PERMIT::r r $826.85 $826.85 DESCRIPTIONACCOUNT '.` `QTY 4 AMOUNTS:;' ° PAID 7-1 _r- , , r .PAID -DATE .NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $193.40 $193.40 4/10/15 ' E 'PAID BY,.'F ; ^x =, METHOD ��c; '� _,1 '.RECEIPT # s`,, ' CHECK # CLTD BY.`e SUNROSE CORPORATION CHECK R4948 16917 MFA t �,. DESCRIPTION ACCOUNT; c ";Q }AMbUNT : PAID k• rPA-1b ATE NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,600.00 $1,600.00 2/2/15 JOE AND BETH GIORDANO CHECK R3566 16718 SKH Total Paid for NEW CONSTRUCTION PLAN CHECK:. $1,793.40 $1,793.40 KDESCRIPTION "`� � f$ACCOUNT ;QTY >'�? AMOUNVF';?AID; � PAID DATE 5, ,E BACKFLOW DEVICE 101-0000-42401. 0 ' $12.09 $12.09 4/10/15 `T PAID BY `'i METHOD ' F { ` ;RECEIPT # E CHECK # x CLTD BY ax; v 4 } SUNROSE CORPORATION CHECK R4948 16917• MFA ? tg'DESCRIPTION' z g ACCOUNTS <, QTY' AMOUNT553 PAID PAID DATE; ,x` BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 $4.83 4/10/15 j CHECK # g'' CLTD BY : §RECEIPT SUNROSE CORPORATION CHECK R4948 16917 MFA a DESCRIPTION az�..ti . ACCOUNTS QTYx � ! AMOUNT: ` `PA 'ID; 9 PAID DATE ; BUILDING SEWER 101-0000-42401 0 $12.09 $12.09 4/10/15 := f' PAID BY x METIiOD RECEIPT # >t z fL " CHECK # CLTD BY _ , Kr SUNROSE CORPORATION CHECK R4948 16917 MFA p DESCRIPTION -: ACCOUNT h AMOUNT : r`' PAID PAID DATE s t, BUILDING SEWER PC 101-0000-02600 0 $12.09 $12.09 •4/10/15 PAID:BY, $ _ sMETHOD r "RECEIPT # "A CHECK # CLTD BY t yy, ..b wtK +€>+ f SUNROSE CORPORATION 'CHECK 114948 16917 MFA , f s +DESCRIPTION n ACCOUNT �L� QTY ° AMOUNT "� f,•c PAID " PAID'DATE a FIXTURE/TRAP 101-000042401 0 $423.15 $423.15 4/10/15 ?PAID BY ; a '."° METHOD �t_ ' RECEIPT # f CHECK # BY- . Wig. ... - . „ .CLTD SUNROSE CORPORATION CHECK R4948 16917 MFA E ''DESCRIPTION ACCOUNT = QTY ; PAID PAID:OATE _ vF 8 i. y,x + ,AMOUNT #+ a FIXTURE/TRAP PC 101-0000-42600 0 $423.15 $423.15 4/10/15 x...; PAID BY ":.�� *METHOD ECEIPT #,, t,: r CHECK # CLTD,BY: > x ..� -: x .:. ::� , <.R 'SUNROSE CORPORATION CHECK R4948 • 16917 MFA >" CRIPTION ` ACCOUNT �, Q TY 3-, ` AMOUNT PAID PAID DATE; e �. GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $36.26 $36.26 4/10/15 f < PAID BY t` . `� F' ° �``' METHOD F RECEIPT # #` " CHECK # f CLTD BY -d �r«, . s . .' SUNROSE CORPORATION CHECK 114948 16917 MFA `DESCRIPTION! `, ,��g g ACCOUNT , QTYx AMOUNT° T f 'PAID PAID DATE t<";. GAS SYSTEM; 5+ OUTLETS PC 101-0000-42600 0 $24.17 $24.17 4/10/15 c PAIDMHOD ET X g R ECEIPT # rC HECK # CLTD BY ¢� .. , SUNROSE CORPORATION CHECK R4948 16917 MFA 'DESCRIPTION t:''_, �ACCOUNTr AMOUNT _ PAID ` PAID.,DATE s#F .`,xK, rt, .®QTY ROOF DRAIN 101-0000-42401 0 $24.18 $24.18 4/10/15 x J. METHOD ;: RECEIPT # Er I`1'CHECK # i;. ' CLTD BY• c r SUNROSE CORPORATION CHECK R4948 16917 MFA ` 't DESCRIPTION is g "; `ACCOUNT v ;QTY AMOUNT ;a. PAID PAID DATE: ROOF DRAIN PC 101-0060-42600 0 $24.18 $24.18 4/10/15 xza BY=q� eta, s,} METHODf e4 'RECEIPT # CHECK # e Kr CLTD By," ,PAID a ;# SUNROSE CORPORATION CHECK R4948 16917 MFA ss? ' ACCOUNT , µ;� r QTY'"AMOUNTa a r PAID <,=f PAID DATE: .pDESCRIPTIONaT� WATER HEATER/VENT 101-0000-42401 0 $24.18 $24.18' 4/10/15 �' t Y � :.. � `�'4;: P'•' G' ,.y rq« 'METHOD *h ? . ,+� `;;x RECEIPT # r y k, 'F,f CHECK # `" CLTD BY r k SUNROSE CORPORATION CHECK R4948 16917 MFA ?� .� DESCRIPTION , � A000UNTr^ " ` "'i" wy 'i AM UNTs'�'`� h �^'w' PAID 'PAID DATE, a.. :"QW, t. r WATER HEATER/VEtNT PC 101-0000-42600 0- $14.50 $14.50 4/10/15 g 3'r ,$ b F' 'PAID $Y '.METHODY},,RECEIPT#� s�'{i hK' l: CHECK#�"z ,ter.' g 4CLTDBY`: SUNROSE CORPORATION -CHECK R4948 , 16917. MFA { 'DESCRIPTION jF, ACCOUNT i AMOUNT�� w c PAID DATE d ,>" *QTY �,y °PAID WATER SYSTEM INST/ALT/REP .101-0000-42401 0 $12.09 $12.09 4/10/15 iPAIDBY �t� METHOD r" # CLTD BY x. �. a+._RECEIPT# ..fir tCHEC SUNROSE CORPORATION CHECK R4948 16917 MFA r 4 1J, - ESCRIPTION °_ t o s; QTY, = h 'AMUUNT c PAIDs s% N PAID DATE, 3 ACCOUNT; WATER SYSTEM INST/ALT/REP PC :101-0000-42600 0 $12.09 $12.09 4/10/15 'PAID BY, �`• P: �`METIiOD 4 $ RECEIPT # '"'g ' CHECK #$ - °CLTD BY � g n :.,i � . SUNRO.SE CORPORATION CHECK R4948 16917 MFA Total Paid for PLUMBING FEES: $1,059.05 $1,059.05 uDESCR1PT10N ACCOUNT :'QTY ' AMOUNTo 4' x4`` ` PAID r� AI °PAIDDATE , q a , ■x� $. SMI - RESIDENTIAL 101-0000-20308 .0 $82.90 $82.90 4/10/15 Tik,•'f`PAID'BY.• "`METHOD ' « -ft- ' CHECK# CTD BY«RECEIPf#" 4 SUNROSE CORPORATION CHECK R4948 16917 MFA Total Paid forSTRONG MOTION INSTRUMENTATION SMI $82.90 $82.90 =yDESCRIBTION 'k{ �` fACCO.UNT 3 '' QTY'PtR AMOUNT I' D ' PAID DATE. v w ..PAI ,« SINGLE FAMILY DETACHED .224-0000-20320 0 $1,837.44 $1,837.44 4/10/15 PAID BY x " ` ;,'; i - METHOD ���' &� ����^ ��sRECEIPT # �y �r � 8 CHECK it � � fstCCTD BY'.' >; , ` z SUNROSE CORPORATION CHECK R4948 16917 MFA Total Paid forTUMF - RESIDENTIAL: $1,837.44 $1,837.44 TOTALS:04 - r • f �` 4 r Description: SUNROSE CORP/SUNROSE CORP/HIDEAWAY/SFD 6692SQ FT Type: BUILDING, RESIDENTIAL Subtype: DWELLING - SINGLE Status: ISSUED Applied: 2/2/2015 SKH FAMILY DETACHED Approved: 4/9/2015 JJO Parcel No: 777400012 Site Address: 80605 VIA MONTECIT6 LA QUINTAcA 92253 Subdivision: TR 29894-4. Block: Lot: 66 Issued: 4/10/2015 IVIFA Lot Sq Ft:. 0 Building Scl Ft- 0 Zoni.ng:'. Finaled: Valuation: $637,719.20 Occupancy Type:, Con struftion Type: Expired: 10/7/2015 MFA', No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: -NEW SFD 6692 SQ. THIS PERMIT DOES NOT INCLUDE POOL SPA, BLOCK WALLS, DRIVEWAY APPROACH, FIRE -PIT, WATER FEATURE OR w BBQ. HOME IS FIRE SPRINKLED PER. 2013 CRC CODES. 66 ,�y �O Printed.: Friday, April 10, 2015 11:58:58 AM I of 8 cmws - YSTEMS ADDITIONAL SITES ....... ... CHRONOLOGY NOL06V '�17Y E�` VNAM&��:�r­� -Aclim:l) P, -tA NON STRUC APPROVED NOTE JIM JOHNSON 4/2/201S 4/9/201S STRUC APPROVED PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 2/27/201S 2/27/201S. STRUCTURAL CORRECTIONS REQUIRED 2/27/201S RECEIVED PLAN CHECK COMMENTS FROM CONSULTANT PHILIP JUARIEZ, 4/7/2015 4/'7/2015 APPROVED PER YOUNG. RECEIVED PLAN. CHECK PICKED UP STEPHANIE KHATAMI 3/3/2015 3/3/201S PLAN CHECK SENT TO KAY HENSEL 2/2/201S 2/2/201S STRUC TO YOUNG, DUE 2/23/1S OUTSIDE PC PLAN CHECK SENT TO . STEPHANIE KHATAM I 3/2S/2015 I 3/2S/201S STRUCTURAL PLAN CHECK SENT TO YOUNG ENGINEERING. OUTSIDE PC I I - . . Printed.: Friday, April 10, 2015 11:58:58 AM I of 8 cmws - YSTEMS PLAN CHECK SUBMITTAL KAY HENSEL 2/2/2015 .�..;w <'� ...., , g wx ,�. ,.w . y.., ... s. x: ,$ h. , k � .. p £��a,., .t 2/2/2015 , �'� ,,• x a �. „ >,•� � t :. � ,cam ,,..�i: 't , -� .. PLANS & DOCS RECEIVED AT FRONT COUNTER BY STEPHANIE RECEIVED .ra. C. ,.; ;:,, PAID:DATE, : RECEIP.,T#`' CHECK;#, {METHOD gPAID"BY r f ART IN PUBLIC PLACES -SUNROSE RESUBMITTAL STEPHANIE KHATAMI 3/25/2015 3/25/2015 0 " $1,094.30 PLAN CHECK SUBMITTED _ 4/10/15 R4948 16917 CHECK . MFA RESIDENTIAL , CALLED SUNROSE CORP THAT PLANS.ARE READY FOR 1ST. TELEPHONE CALL JIM JOHNSON 3/3/2015 3/3/2015. SUNROSE CORRECTIONS BSAS'SB1473 FEE 101-0000-20306 0 Y $26.00- 4/10/15 CALLED SUNROSE TO INFORM THEM THE PLANS ARE READY TELEPHONE CALL JIM JOHNSON 4/9/2015 MFA 4/9/201S- TO ISSUE. AFTER SCHOOL FEE ARE PAID Total Paid for BUILDING STANDARDS ADMINISTRATION ' • • BSA: CONTACTS... NAME:. s 'ADDRE5S1 `> CITY STATE 21P ;-PHONE;;sFAX�F� :NAME`TYPE :.°:;:�...:a�.q:--x::.,��.��.'...$.,.`.r_..,..•�«.,:_;.�m.�=-�t. ...,,,a,�.. a: -:'w ...Y -;-.,_M ,�.�..�;.�. ,. APPLICANT SUNROSE CORPORATION 72-850 SOMERA ROAD PALM DESERT CA 92260 (760)773-6633 CONTRACTOR SUNROSE CORPORATION 72-856 SOMERA ROAD PALM DESERT CA 92260 (760)773-6633 OWNER JOE_ AND BETH GIORDANO 40101 MONTEREY AVE. RANCHO CA •(760)773-6633 #131-214 MIRAGE ` FINANCIAL INFORMATION .�..;w <'� ...., , g wx ,�. ,.w . y.., ... s. x: ,$ h. , k � .. p £��a,., .t t ...E �€:,. e {ac , �'� ,,• x a �. „ >,•� � t :. � ,cam ,,..�i: 't , -� .. ng.I,Fs r,—.kL :. ,g. X;.F. , R... r.� :..:..:' .:DESCRIPTION = :- ACCOUNT _ f __. TY AMQUNT .,:. %...E �.;. .<:PAID ,ts ,,- .ra. C. ,.; ;:,, PAID:DATE, : RECEIP.,T#`' CHECK;#, {METHOD gPAID"BY r f ART IN PUBLIC PLACES -SUNROSE 270-0000-43201 ' 0 " $1,094.30 $1,094.30 4/10/15 R4948 16917 CHECK . MFA RESIDENTIAL , CORPORATION, Total Paid forART IN PUBLIC PLACES - AIPP: $1,094.30 $1,094.30. - SUNROSE BSAS'SB1473 FEE 101-0000-20306 0 $26.00 $26.00- 4/10/15 R4948 .16917 CHECK MFA CORPORATION Total Paid for BUILDING STANDARDS ADMINISTRATION ' $26.00 $26.00 ". BSA: SUNROSE DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $942.00 4/10/15 R4948 16917 CHECK MFA CORPORATION DIF - COMMUNITY SUNROSE 254-0000-43200 0 $129.00 $129.00 4/10/15! R4948 16917. CHECK MFA CENTERS Printed: Friday, April 10, 2015 11:58:58 AM 2 of 8 sysrr:Ms `DESCRIP'.TIO`CHECK4-'� ACCOUNT CITY 7 -- 47;: iD.7' PAID DATE. ',.RECEIPT.# �tMETHODA -'I�'PAlb B :LTD. -AMOUNt,4� DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $433.06 4/10/15 R4948 16917 CHECK S * UNROSE MFA' CORPORATION DIF LIBRARIES 253-0000-43200 0 $344.00 $344.00 4/10/15 R4948 16917 CHECK SUNROSE MFA' CORPORATION DIF - PARK 256-00,00-43200 0 $40.00 $40.00 '4-/10/15 i4948 16917 CHECK SUNROSE MFA MAINTENANCE CORPORATION DIF - PARKS/REC 251-0000-43200 0 $2,049.00 $2,048.00 4/10/15 R4948 16917 CHECK SUNROSE MFA CORPORATION DIF - STREET 255-0000-43200 0 $116.00 $imob 4/10/1S R4948 16917 CHECK SUNROSE MFA MAINTENANCE CORPORATION DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 2. $2,842.00 60 4j10'/1S R4948 16917. CHECK SUNROSE MFA CORPORATION Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 $6,894.00 TEMP POWER SERVICE 101-0000-42403 0 $24.17 $24.17 4/10/15 R4948 16917 CHECK SUNROSE MFA. CORPORATION TEMP POWER SERVICE 101-0000-42403 0 $16.92 $16.02 4/10/15 R4948 16917 CHECK SUNROSE. MFA PC CORPORATION Total Paid for ELECTRICAL: $41.09. $41.09 RESIDENTIAL, EA. 101-0000-42403 a $98.64 $98.64 4/10/15 R4948 16917 CHECK., SUNROSE MFA ADDITION 1,000SF CORPORATION RESIDENTIAL, EA 101-0000-42600 0 $40.64 $40.64 4/10/15 R4948 16917 CHECK SUNROSE MFA ADDITION 1,000SF, PC CORPORATION RESIDENTIAL, FIRST 101-0000-42403 0. $145.03 $145.03 4/10/15 R4948. 16917 CHECK SUNROSE MFA. 1,000SF 1 CORPORATION RESIDENTIAL, FIRST 101-00 - 00-42600 0 $47.86 $47.86 4/10/15 R4948 16917 CHECK SUNROSE MFA 1,000SF, PC CORPORATION Total Paid forELECTRICAL - NEW CONSTRUCTION: $332.17 $332.17 RESIDENTIAL FINISH 101-0000-42600 0 $143.00 $143.00 4/10/15 R4948 16917 CHECK SUNROSE 'CORPORATION MFA GRADING PC FTotal Paid forGRADING: $143.00. $143.00 ,Printed: . Friday, April 10, 2015 11:58:58 AM 3 of 8 CRFWSYSTEMS Printed: Friday, April 10, 2015 11:58:58 AM 4&f8 cmwsysTems DESCRIPTION-:' 4� �,-�75% ACCO QTY - T!" nD E 4.PAID I CHECK METHOD: J, ID BY CONDENSER/COMPRES 101-0000-42402 0 $217.56 $217.56 4/10/15 R4948 16917 CHECK SUNROSE MW SOR CORPORATION CONDENSER/COMPRES' 101-0000-42600 0 $145.02 $145.02 4/10/15 R4948 16917 CHECKMFA SUNROSE SOR PC CORPORATION EXHAUST HOOD 101-0000-42402 0 $24.18, $24.18 4/10/15 16911 CHECK SUNROSE MFA .114948 CORPORATION, EXHAUST HOOD PC 101-0000-42600 0 $9.66- $9.66- 4/10/15 R4948, 16917- CHECK SUNROSE MFA CORPORATION FURNACE 101-0000-42402 .0 $217.56 .$217.56 4/16/15 R4948 16917 CHECKr SUNROSE MFA • CORPORATION 'FURNACE PC 101-0000-42600 0 $145.02' 4/10/15 R4948 16917 CHECK SUNROSE MFA .$14S.02 CORPORATION VENT FAN 101-0006-42402 0 $84.63$84.63 4/10/15 R49U i6917 CHECK SUNROSE MFA CORPORATION VENT FAN PC 101-0000-42600- '0 $33.81- $33.81' 4/10/15 R4948 16917 CHECK SUNROSE M I FA CORPORATION WALL HEATER. lol-oo6o-4'2402 0:- '$74.-1j 7 3'. 4/10/15 R4948 16917, CHECK SUNROSE MFA CORPORATION WALL HEATER PC 101-0000-42600 '0 '$36.27 $36.27 4/10/15 R4948 16917 CHECK SUNROSE MFA' - CORPORATION Total Paid forMECHANICAL: $987.84. $987.84 NEW CONSTRUCTION 101-0000-42400 0 .$826.8S $826.85 4/10/15 R4948 16917 CHECK SUNROSE MFA. 10 CORPORATION N Total Paid for NEW CONSTRUCTION PERMIT: $826.85 $826.85 NEW CONSTRUCTION 101-0000-42600 0 $193.40 $193.40 4/10/15 R4948 16917 CHECK SUNROSE MFA PLAN CHECK CORPORATION NEW CONSTRUCTION 101-0000-42600 0 $1,600.00 $1,600.00 2/2/15 R3566 16718 CHECK JOE AND'BETH- 'SKH PLAN CHECK GIORDANO, Total Paid for NEW CONSTRUCTION. PLAN CHECK: $1,793.40 $093.40 Printed: Friday, April 10, 2015 11:58:58 AM 4&f8 cmwsysTems _,�, r „ • r-�; � r. b :. -'.-t .�„ �, �-s_' <. t fir•-, `•x 'F °CL TDA' Ae' DESCRIPTION > ACCOUNT „ rt,CfTYr ,, AMOUNT ._ } .z.m" - PAID ..,; r s ,�..t�. .PAID DATE RECEIPT ,#: ,CHECK#;W, METHOD 1 PAIDBY ,� _:' } •... .- a:.v 5::. ., .,. .... ldr i. ': �..:: •S�° .. '°,� ! s ;la' 'S' gY.. BACKFLOW DEVICE 101-0000-42401 0 $12.09. $12.09 4/10/15 R4948 16917 CHECK SUNROSE MFA' CORPORATION • BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 $4.83 4/10/15 R4948 16917 CHECK, SUNROSE MFA• CORPORATION BUILDING SEWER 101-0000-42401 0 $12.09 $12:09 4/10/15 R4948 16917 CHECK SUNROSE MFA CORPORATION BUILDING SEWER PC' 101-0000-42600 �0 $12.09 $12.09 4/10/15 R4948 16917 CHECK SUNROSE MFA CORPORATION- . FIXTURE/TRAP 101-0000-42401- 0 $423.15 •'$423.15 4/10/15 4 R4948� 16917 -'CHECK, SUNROSE MFA , CORPORATION FIXTURE/TRAP PC 101-0000-42600 0 $423.15 $423.15 R4948 16917 CHECK SUNROSE MFA _ .4/10/15 CORPORATION GAS SYSTEM, 5+ 101=0000-42401 0 $36.26 $36.26 4/10/15 R4948 , .16917 CHECK SUNROSE MFA OUTLETS .' CORPORATION GAS SYSTEM,.S+101-0,000-42600 101-0000-42600 0 $24.17 $24.17 4/10/15 R4948 16917 CHECK MFA OUTLETS PC CORPORATION ROOF DRAIN • . 101-0000-42401 0 $24.18 $24.18 4/10/15 R4948" 16917 CHECK' ti ' SUNROSE .,MFA CORPORATION - ROOF DRAIN PC 101-0000-42600 0 $24.18 $24.18 4/10/15 R4948 16917 CHECK SUNROSE y CORPORATION MFA WATER HEATER/VENT 101-0000-42401 0 $24.18 $24.18 4/10/15 R4948 16917 • CHECK SUNROSE MFA - CORPORATION WATER HEATER/VENT 101-0000-42600 0 , $14.50 $14.50. 4/10/15 R4948 16917 CHECK SUNROSE MFA PC CORPORATION WATER SYSTEM 101-0000-42401 0 $12.09 $12.09 4/10/15 R4948 16917 CHECK SUNROSE MFA INST/ALT/REP CORPORATION WATER SYSTEM 101-0000-42600 0 $12.09 $12.09 4/10/15 R4948, 16917 CHECK SUNROSE MFA INST/ALT/REP PC - CORPORATION . Total Paid for PLUMBING FEES: $1,059.05. $1,059.05 Printed: Friday, April 10, 2015 11:58:58 AM 5 of 8 SYSTEMS INSPECTIONS Ty DATE CITY MOUNT-�'- PAID DATE, REdEIJPT2#.­ �,tCHECK # METI­106�2 PAID OY'1-4L REVIEWS SMI - RESIDENTIAL 101-0000-20308 0 $82,90 $82.90 4/10/1S R4948 16917 CHECK SUNROSE MFA-' 2/2/2015 2/23/2015 2/13/2015 REVISIONS REQUIRED SEE ATTACHED 1S,T NON STRUC PLAN CHECK, CORRECTIONS KATHRYN CORPORATION Total.Paid forSTRONG MOTION INSTRUMENTATION SMk $81.90 $82.90 SINGLE FAMILY 224-0000-20320 0 $1;937.44' $1,837.44 4/10/_1S R494 8 16917 CHECK SUNROSE MFA' DETACHED 1ST PW GREEN AMYYU_ 3/18/201S CORPORATION 3/2S/2015 Total, Paid forTUMF - RESIDENTIAL: $1,837.44 $1,837.44 TOTALS: $15,118.04 $15,118.04 INSPECTIONS Ty DATE PARENT PROJECTS wl REVIEWS NOTES NON-STRUCTURAL JIM JOHNSON 2/2/2015 2/23/2015 2/13/2015 REVISIONS REQUIRED SEE ATTACHED 1S,T NON STRUC PLAN CHECK, CORRECTIONS KATHRYN STRUC TO YOUNG DUE 2/23/2015 STRUCTURAL 2/2/2015 2/23/2015 2/27/201S REVISIONS REQUIRED 1ST CK DUE 2/23/15 STRUC RFC 2/27/201S SAMUELS 1ST PW GREEN AMYYU_ 3/18/201S 3/25/2015 3/2S/2015 READY FOR APPROVAL NON-STRUCTURAL JIM JOHNSON 3/2S/iOlS 4/8/201S 4/2/2015 APPROVED APPROVED NON STRUC APPROVED KATHRYN 3/25/2015 4/8/2015 4/7/2015 APPROVED HOW INFORMATION Printed: Friday, April 10, 2015 11:58:58 AM 6 of 8 Printed: Friday, April 10, 2015 11:58:58 AM 7 of 8 ' SYS7EtitS ATTACHIVIFNTS Attachment Type 741— CREATED'' OWNER - DESCRIPTION PA ISUBMW ETRAKITENA ._,_ DOC 2/17/2015. JIM JOHNSON 80-605 VIA 80-605 VIA 0 MONTECITO.docx MONTECITO.docx 2ND SUBMITTAL 2ND SUBMITTAL ARCHITECTURAL ARCHITECTURAL DOC 3/25/2015– STEPHANIE KHATAMI RESPONSE 3-25-2015 RESPONSE 3-25-2015 0 80605 VIA 80605 VIA MONTECITO.pdf MONTECITO.pdf 2ND SUBMITTAL 2ND SUBMITTAL - STRUCTURAL RESPONSE STRUCTURAL' RESPONSE DOC _ 3/25/2015 STEPHANIE KHATAMI COMMENTS 3-25-2015 COMMENTS 3-25-2015 _ 0 80605 VIA 80605 VIA r = - - MONTECITO.pdf MONTECITO.pdf DEBRIS MANAGEMENT DEBRIS MANAGEMENT DOC "3/25/2015 STEPHANIE KHATAMI PLAN 3-25-2015 80605 PLAN 3-25-2015 80605 "-� • �0 " - VIA MONTECITO.pdf VIA MONTECITO.pdf , HOA APPROVAL 3-25- HOA`APPROVAL 3-25- " DOC 3/25/2015 STEPHANIE KHATAMI 2015 80605 VIA 2015 80605 VIA. 0; ! - MONTECITO.pdf -MONTECITO.pdf _ ' GRANT DEED 777-400- GRANT DEED 777.400= DOC . 3/25/2015 STEPHANIE KHATAMI 012 3-25-2015 80605 012 3-25-2015 80605�.. • 0 - ' VIA MONTECITO.pdf VIA MONTECITO.pdf . , SOILS REPORT 3-25- SOILS REPORT 3-25- D06 3/25/2015 STEPHANIE KHATAMI 201580605 VIA 2015 80605 VIA 0, ' MONTECITO.pdf MONTECITO.pdf 2ND SUBMITTAL - 2ND SUBMITTAL - DOC 3/26/2015 STEPHANIE KHATAMI CORRECTION LIST AND 'CORRECTION LIST AND 1 COMMENTS 9COM2014 COMMENTS BCOM2014 -3047.pdf -1047.pdf - DOC 3/26/2015 STEPHANIE KHATAMI PM10 APPROVAL 03-25- PM10 APPROVAL 03-25- 0 15.pdf 15.pdf. Printed: Friday, April 10, 2015 11:58:58 AM 7 of 8 ' SYS7EtitS °"Sn • .i .. _ • � . +? Y ,tom " -, y�'s+ , + l+ w�5. - - - - + •`• � -. - - ._ i'� F Printed: Friday, April 10, 2015 11:58:58 AM SYSTEMS 8 of 8 Building Address Owner or 0J o� ti 3 e,14 Mailing Address Titl� 4 4 a" P.O. BOX 1504 -�71 78-495 CALLE TAMPICO ��C/ / SLA QUINTA, CALIFORNIA 92253 APPLICATION ONLY (�� p✓�(�CsHD BUILDING: TYPE CONST. OCC. GRP. CRY IqY.�� A.Number—7 72 —� O Tel. 7� p — Legal Description 4-0 T 4::-D ,a 773-cP Project Description state LIC. clry & Classif.3 �? e 7 D I Lic. # '6'e-s: e ,, �j,., Address Tel. Q s . I Va4 V- ILic. # LIC CONTRACTOR'SOECLARATION I hereby affirm that I argecensedyfider provisions of Chapter 9 (commencing with Section 7000) of Division 3 of thea inessppfl Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION 4 i I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contrac- tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penally of not more than five hundred dollars ($500). OI, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to sett -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation taws of California. Date Owner NOTICE TO APPLICANT If, alter making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration it work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip Sq. Ft. /� No. Size 476 7 ,;"_ Stories Newx Add C1 Alter❑ Estimated Valuation No. DIN. Units Repair❑ Demolition PERMIT AMOUNT Plan Chk. Dep. I Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL 0 CONTACT INFORMATION NAME: PHONE: ZONE: BY: Minimum Setback Distances: Front Setback from Center Line — Rear Setback from Rear Prop. Line _ Side Street Setback from Center Line Side Setback from Property Line — FINAL DATE Issued by: Validated by: Validation: INSPECTOR Date Permit WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE 6 }oachella Valley Unified School District 83-733 Avenue 55,.Thermal, CAS 9.2274 (760) 398-5909 — Fax. (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA:. AMOUNT - LEVEL ONE AMOUNT :: : LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: • DATE: " - RECEIPT: ' CHECK#: INITIALS ' CERTIFICATE OF COMPLIANCE (California Education Code 1.7620) Project Name:jThe Hideaw y Date: April 10, 2015 Owner's Name: Joe Giordano Phone No. 760-773-6633 Project Address: 80-605 Via Montecito, LaQuinta Project Description: New SFD ' APN: 77.7-400-012 Tract #: ` .. • Lot #'s:.: Type of Development:..: Residential Commercial Industrial Total Square Feet of Building Area: 6692: Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of.perjury and further represents that he/she is. authorized to sign on behalf of the owner/developer.: D1ited: April 10; 2015 Signature: 14111 SCHOOL DISTRICT'S REQUIREMENTS• FOR THE ABOVE PROJECT HAVE.BEEMOR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING:. (CIRCLE ONE)... Education Code • Gov. Code.,. Project Agreement Existing Not Subject to Fee .17.620 65995 Approval _ Prior to 111/87 Requirement Number of Sq.Ft. 6692 Pursuant to AB 181 any_ room additions or enclosures of 500 I sq. ft. or less are exempt from developer fees. Any mobile Amount per Sq.Ft. $3.36homes being.relocated within the same school district's Amount Collected $22485.12 ,jurisdiction are. exempt from developer fees. Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Laurie Howard, Secretary Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST .OF FEES AND STATEMENT OF FEES Section 66020 of the, Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other'exactions ("Fees"), of the 90 -day period to protest the imposition of these Fecs and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or. the.validity thereof; commences with the payment of the ,fees or performance of any other requirements as'described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or. in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the. date:ofissuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. M V:c/mydo C'sldevfees/cei-ti f icate of compliance form updated 3-2007 1 l/2010 i DOC # 2015-0067803 02/1912015 04:31 PM Fees: $50.00 RECORDING REQUESTED BY: Page 1 of 6 Recorded in Official Records County of Riverside WHEN RECORDED MAIL THIS DEED AND, UNLESS Peter Aldana OTHERWISE SHOWN BELOW. MAIL TAX STATEMENT TO' Assessor, County Clerk & Recorder Name: City of La Quinta . Street 78-495 Calle T*This document was electronically submitted aTampico Address: p to the County of Riverside for recording" Receipted by: MRUIZ City Stale La Quinta, CA 92253 & Zip Title Order No.: Escrow No.: brXCEADOWTHIS Quitclaim Deed The undersigned Grantor(s) declare(s) DOCUMENTARY TRANSFER TAX IS ❑ Computed on Full Value of the interest or property conveyed, or Computed on full value less value of liens or encumbrances remaining at time of sale, [� UnincorporateArea City of La Quinta .. Parcel No.: 777400-012 FOR A VALUABLE CONSIDERATION,. receipt of which is hereby acknowledged, Joseph Giordano and Beth Lynn Giordano, Husband and Wife as Joint Tenants. Do (does) hereby REMISE, RELEASE AND FOREVER QUITCLAIM to: Joseph Giordano and Beth Lynn Giordano, Husband and Wife as Joint Tenants The following described property in the County of Riverside State of California See Exhibit "A" attached hereto and made a part hereof. This Deed is being recorded pursuant to Lot Line Adjustment 2014= 02 approved by the City of La Quinta onFeb✓ugy^y. 9 2 -VIS - Date AI? ROVED BY CIN OF LA QUINTA - natur f G nlor �- Joseeph Giordano •_Timothy JonaonPri d Nam o , raptor ', [ iblic Works Director/City Engineer 'Signatureof Granto Seth Lir n Giordano 'Printed Name of Grantor P Notary Acknowledgements attached. MAIL TAX STATEMENTS TO PARTY SHOWN ON FOLLOWING LINE: IF NO PARTY SHOWN, MAIL AS DIRECTED ABOVE. Joseph and Beth Lynn Giordano 4034 Arhaus Drive, -Hermitage, PA 16148 Name Street Address City & State DOC #2015-0067803 Page 4 of 6 02/19/2015 04:31 PM EXHIBIT „A„ LEGAL DESCRIPTION ADJUSTED LOT 66 OF TRACT NO. 29894-4 PARCEL B That certain parcel of land located in the City of La Quinta, County of Riverside, State of California, being Lot 66 of Tract No. 29894-4, as shown by a map on file in Book 351, Pages 49 through 57 inclusive of Maps, Records of said county, together with that portion of Lot 65 of said Tract 29894-4 more particularly described as follows. COMMENCING at the northeast corner of said Lot 65; Thence along the northerly line of said Lot 65 through the following three courses: North 64°15'26" West 22.89 feet to the beginning of tangent.curve, concave southerly, having a radius of 74.50 feet; Thence along said curve westerly an arc distance of 52.17 feet through a central angle of 40°07'15" to.a point of reverse curvature with a,tangent curve concave northerly, having a radius of 51.50 feet, a radial line of said reverse curve bears South 14'22'41" East to said point; Thence along said reverse curve westerly an arc distance of 33.84 feet through a central angle of 37'39'03" -to the POINT OF BEGINNING; Thence radially from said curve South 23°16'22" West 5.01 feet to a line parallel with and 10.00 feet southeasterly of the northwesterly line of said Lot 65; Thence along said parallel line South 59°39'08"• West 164.95 feet.to an intersection with the southwesterly line of said Lot 65, said point being located on.a non -tangent curve, concave northeasterly, having a radius of 252.58 feet, a radial ine of said curve bears South 45°40'10" West to said point, said point also being the POINT OF TERMINATION. EXCEPTING THEREFROM interest in all water, minerals, oil, gas petroleum, other hydrocarbon substances and all geothermal energy sources in or under said land or which may be produced from said land. CONTAINING: 25,085 Square Feet, more or less. SUBJECT TO all Covenants, Rights, Rights -of -Way and Easements of record. Graphically depicted on 'EXHIBIT "B" — PLAT , attached hereto and by this reference made a part hereof. P Page 1 of,2 1 d . A notary public of other officer completing this certificate verifies only the identity of the individual who signed the document, to which this certificate is attached, and not. the truthfulness,•accuracy, or validity of that document State of California ) County of Riverside ) On February 9, 2015 before me, ef' S0. . 1 +' 10M1�k!L Notary Public, personally appeared TIMOTHY R..JONASSON who proved to me on the basis of satisfactory evidence to be the person whose name is subscribed to the within instrument, and acknowledged to me that he. executed the- same in his authorized capacity, and that by his signature on the instrument the person, or the entity upon behalf of which the person acted, executed the instrument. I certify under PENALTY' OF PERJURE' under the' laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. Signature�74A_ . (seal) TERESA THOMPSON X Commission ;r 2030796 _ Notary Public - California D z a%• Riverside County My Comm. Expires Jun 24, 2017 r DOCUMENT: QUITCLAIM DEED re: APNs 777-400-012- owners: Joseph Giordano and Beth Lynn Giordano. February 23, 2015 Mr. and Mrs. Joe Giordano 4034 Arhaus Drive Hermitage, PA 16148 Re: Lot 66D at 80605 Via Montecito Final Design Review #1 Dear Mr. and Mrs. Giordano, This correspondence shall serve as notification that the Hideaway Design Review 'Committee (DRC) reviewed your final construction document submittal at their February 17, 2015 meeting. The project was approved to start construction subject.to a Pre -Construction Meeting being held at the lot. In addition, the following comments must be addressed prior to pouring the slab at the lot: 1. As a reminder, a stone mock-up will be required in the field prior to installation as the color board does not provide enough information for a proper review of the material. In addition, all finish samples, including the pool tile, pool coping, infinity edge material(s), pavers, etc. must be provided for review and approval. 2. Please clarify the window sill detail which is called out as "7" but the committee believes to be «10„ 3. Verification that the chimney cap detail will properly screen the manufactured flue caps is required. 4. All exterior sconces must be submitted for review and approval. 5. The path light fixture is approved; however, the amount of fixtures in the rear yard should be reduced as well as the bulb wattage (or relative LED output). . 6. The irrigation valves in the front .yard are proposed too close to the street and should be located out of view. 7. All fire bowls and landscape pots/bowls must be submitted for review and approval prior to installation in the field. 8. The rear yard plinths must be reduced for 24" high to a maximum height of 18 inches. 9. As a reminder, Gerry Tarsitano will need to review the most recent plan submittal and provide comments in addition to those provided on the December 22, 2014 letter. Please contact Brook Marshall at 760-219-8057 or by email at DRCFacilitator@gmail.com with any questions or to schedule your Pre -Construction Meeting once a Building Permit has;.been obtained. Sincerely, THE HIDEA WA Y DESIGN RE VIE W COMMITTEE am Title: Date: cc: Stracts John Krieg Gerry Tarsitano Mike Tuvell DRC File Pursuant to Cal. Civil Code, any rejection by the DRC may be appealed to the Board of Directors for the Association. /f you wish to pursue an appeal, please contact the Association's property manager directly. 603( CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORK_ S CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 9/25/2009 Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date: 03 / 17 / 15 Developer: Sunrose Corporation Tract No.: 29894-4 Tract Name: The Hideaway Lot No.(s):66D Address(s): 80605 Via Montecito Phone Number: ( 760 ) 773-6633 The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the Building & Safety Department: ❖ CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4, #5 & #7 BELOW ❖ TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW ❖ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1 #2 #3 #5 & #7 BELOW ❖ WALLS, SIGNS, OTHER: PROVIDE ITEM #6 BELOW 1. Attach; Pad rElevation Certificates in compliance with the approved design .elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation Certificate can be provided. 2. Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils Engineer. Recently rough graded residential developments which have a previously approved geotechnical certification are exempt from this requirement. 3. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots. 4. Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10-plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 certification number is required. 5. Attach a copy of the rough or -precise grading plan to the Public Works Department showing building location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain development plan. 6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. 7. Complete and sign the attached water quality management plan .(WQMP) exemption form, if applicable. PW approved building construction projects require either a WQMP or a completed WQMP exemption form. Approved maps/plans may be viewed at the following link: http://www.la-guinta.or-q/PlanCheck/m search.aspx I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff. Recommended by: Date: -/ 2 / /J UZ Public Works Distribution: ( Green Sheet to Building & Safety ( ) Green Sheet to Planning Department Declined for approval for reason(s) as follow(s), please correct and resubmit: TAChecklists - Forms & Applications\Fonns & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc City of La Quinta - PM10 Fugitive Dust Control Project Information Construction Phase PM10 Agreement (<1 acre/lot or Infill Project) Project Information Project Contractor: Sunrose Corporation Project Phase (check one) Construction Demolition Project Name: Giordano Residence Project Tract/Lot Numbers: 29894-4 / Lot 66D Project Street Address: 80605 Via Montecito Total Acres in Active Construction (<1 acre per Lot):,azo 30 • 03 17 15 03 17 15 Anticipated Start Date: / / Anticipated Completion Date: / / PM10 Contact Information Please note: Dust control is required 24 hours a day, 7 days a week, regardless of construction status. Person listed below is responsible for dust control during business and non -business hours. Name: Jenny McIntire Title: Administration Company Name: Sunrose Corporation Mailing Address: 40101 Monterey Ave. #61-214 City, State, ZIP Code: Rancho Mirage, CA 92270 Primary Phone #: 760-773-6633 Fax #: 760-773-6634 24 Hour Emergency Phone#: 760-773-6633 Cell Phone #: 760-702-0119 Email Address: sedonahomes@dc.rr.com PM10 Certificate #: ICV1402-000405-449 The above stated property owner (or authorized representative): ❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; ❖ Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. ❖ Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; ❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; ❖ Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes; ❖ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control plan or any City/Co(unty initiated abatement activities. l` a--- % I/ / 7 /.-2-0 /h i Signatdre of P((Ierty Owner or Authorized Representative Dafe / T:\Checklists - Forms & Applicatians\Fonns & ApplicationslGREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doC Building Permit Number. ° Project Description: SFR Exempt: O (Materials may contain hazardous wastes and are not subject to recycling provisions) c�°F.- 9 Construction Debris Management Plan Plan Submittal Date 3/16/2015 Job site Address 80-605 V8 Monteclto Owner's Name : Mr. & Mrs. Giordano c/o Sunrose Corp Number, Street,. or PO Box 4.01.01 Monterey Ave #B1-214 City, State, Postal code Rancho Mirage, Ca. 92270 Owners Phone Number 760473-6633 Owner's E-Mail Address Project Managers Name Jenny Project Managers Phone Number 760-773-6633 Project Managers E-mail Address eedonahomeafcedc.rr.com Builder Contractor Sunrose Corp Number, Street or PO Box 40101 Monterey Ave #B1-214 City, State, Postal Code Palm Springs, Ca. 92264 Project Square Footage 6629 sq ft City. Approval By Date of City Approval Materials To Be Discarded: Product Tons Trash ` 27.00 Not recyclable Product Tons Asphalt 0.00 Recyclable Masonry (broken) 0.00 Recyclable Brick/Block 0:00 Recyclable Plaster 7.00 Recyclable Cardboard 0.00 RecyclableScrap Metal 0.00 Recyclable Commingled 0:00 Recyclable Tile (floor) 0.50 Recyclable Concrete 26.50 Recyclable : Tile (root)1.00 Recyclable Drywall 3.25 Recyclable Wood 8.75 Recyclable Donated / Reuse" 0.00 Recyclable Landscape Debris 0.00 Recyclable "Describe Items Totals: Recycle Trash Projected Diversion: 47.00 27.00F 63761% 1 understand it Is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur.) hereby certify that completion; implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsite waste Is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re-use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is Issued in the name of the property owner(s) and shall: remain theirproperty throughout, the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP Is still Issued in the name of the propertyowner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bl-monthly repa elf-hauling all refuse material from this project site must be taken to an approved recycler or transfer Owner / Developer / Project Manager /Supenntendant Date YOUNGa w a ENGINEERING a Q r� letter of TransnAttal Y T '. To `. City of La Quinta .�. Today's Date:,4-7=15. A i 78-495 Calle Tampico t 'CityDue Date `-;,4-8=15 La Quinta, CA',92253 `- Project Address. 80605 Via Montecito Attn: Kay `Plan Check M. BRES 2015-0034 Submittal ❑ 151 '❑ qm. Y , Sin �r » y a y r ❑ 3rd x`. ❑ Other, We are forwarding:'®- _ By Messenger ❑ `k By Mail (Fed Ex'ot UPS) �• ❑ Your Pickup f Includes: # Of Descriptions Includes - - 14 Of "Descriptions:.. `rCopies: "L �•_ 7r *.Copies: >• y , ® 1 Revised Structural Plans ' t - ❑°": Structurat�Plans:• •s ' ❑ -Structural Calcis bons""'6 p 1 Revised Struct. Calcs ' Truss`Calculatio'nsbfiloor sL4 j IV "� ® 1 and Roof Revised:Truss, • �+ ` � :•' Soils Report '' .x Revised Soils Report Structural Coment Lis i m� D , ©a 2 14 0 _ Approved 'Structural Plans r Responses �t �.k- LA QLIf��a , PP ® .1 Redlined Structur I Plans I Approved Structural Calcs ® 1 Redlined StrttejralrjCa,Icsy pEVELCr' �1CT Approved Truss.Calcs ❑ `'Redlined Truss Calcs ❑ '� Approved, Soils Report Redlined Soils,Reports`' 4, 0 , : .'Other: ' Comments: Structural content is.approvable. y � If you have, ariy questions, please call: f" �` f Time = 1.75 HR' ' This Material Sentx`for " ❑' .` Your Files ®t -Per Your Request ' ❑' Your Review 1 ,. c"R- ❑ `Approval syn . r _' ❑ Checking,,!:❑ the'request of Other: ❑ °: y BY: Kathryn Samuels Palm Desert Office : ® (760) 772-5107. : ti ' Other : ;❑ + • - # r z w ..� r ,, moi, t3 14t x , _ r 4 BUILDING ENERGY ANALYSIS REPORT PROJECT:. s Custom Residence Lot 66D, The Hideaway La,Quinta, CA 92253 Project Designer.: _ l STRACTS, Inc.. 550 S. Oleander Rd.. Palm Springs, CA 92264 (760) 636-8951 ' Report, Prepared by: . ` .Tim Scott Scott Design and Title 24,,,Inc,. 77085 Michigan Drive Palm Desert, CA 92211 (760) 200-4780 G RE1VED CE L FEB 0 ? 2015 ` CITY CJS` LA QUINTA COMMUNITY DEVELOPMENT Job Number: Date! 1/8/2015 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. f This program developed by EnergySo ft, LLC—www.ehergysoft.com. EnergyPro 6.4 by EnergySoft User Number. 6712 ID: CERTIAE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IMOD Project Name: Custom Res, Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xm1 CF*F-01. Page 1 of 14 1 GENERAL INFORMATION 01 Project Name Custom Res 02 Calculation Description Title 24 Analysis 03 Project Location Lot 66D, The Hideaway 04 City La Quinta 05 Standards Version Compliance 2014 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3b1 (694) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.4 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 6692 15 Al� Number of Zones 4 16 Slab Area (FT2) 5789 17 Number of Stories 2 18 Addition Cord. Floor Area N/A o1�9'� Natural Gas Available Yes 20 Addition Slab Area (FT2) N/A #C2 Glazing Percentage (%) 26.4% A*, COMPLIANCE RESULTS 01 Building Complies with Computer Performance Afth.� 02 This building Incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shomi*below This compliance analysis is vvaa id only for permit applications through December 31, 2014 ENERGY USE SUMMARY 04 05�®"r 06 07 08 Energy Use (kTDV/ft2-yr) Standard Proposed iDeslgn Design Compliance Margin Percent Improvement Space Heating fj 2.87 2.56 0.31 10.8% Space Cooling � 88.35 84.16 4.19 4.7% IAQ Ventilation �~ 1.10 1.10 0.00 0.0% Water Heating 91 4.05 5.28 -1.23 -30.4% Photovoltaic Offset °1@+ — 0.00 0.00 — Compliance Energy Total a 96.37 93.10 ed. 3.27 3.4% *o°Y► Registration Number: �� CA Building Energy Efficiency Stan ds - 2013 Residential Compliance Registration Date/Time: Report Version - CFSR-01062015-694 HERS Provider: Report Generated at: 2015-01-08 15:58:49 CERTIF& OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD CF*F-M Project Name: Custom Res Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Page 2 of 14 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xml ° REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cathedral Ceiling • Window overhangs and/or fins • Exposed slab floor in conditioned zone HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • — None — r HVAC Distribution System Verifications: Pie • Duct Sealing a®"d • Verified low -leakage ducts located entirely in conditioned space Domestic Hot Water System Verifications: •. �� — None — ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components inclu%in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (uch as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system., Reference Energy U�s� _»� , j Energy'�DesignRRaUngf Margin, Percent Improvement Total Energy (kTDV/f2-yr)* 131.60 3.27 2.5% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03, 04 05 06 07 Project Name AN Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms "Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Custom Res 6692 1 12 4 0 2 49 Registration Registration Number: ,��� CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-01062015-694 HERS Provider: Report Generated at: 2015-01-0815:58:49 CERTIFOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Custom Res Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xml CFOF-91 Page 3 of 14 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Master Suite Conditioned HVAC 11 1395 11.5 DHW Sys 1 Living/Dining/Kit/Entry Conditioned HVAC 2,3 & 42 3742 11.5 DHW Sys 1 2nd Floor Conditioned HVAC 53 903 8.9 DHW Sys 1 Casita Conditioned HVAC 64 652 10 DHW Sys 3 lei .0 Registration Number: '41 Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standa'r'ds -2013 Residential Compliance Report Version - CFiR-01062015-694 Report Generated at: 2015-01-08 15:58:49 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Custom Res Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xmi CF*F-G1 Page 4 of 14 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (W) Tilt (deg) 65d Wall Master Suite R-21 Wall (W.19.2x6.16) 65 - specify - 250 0 90 155d Wall Master Suite R-21 Wall (W.19.2x6.16) 155 - specify - 624 63.7 90 245d Wall Master Suite R-21 Wall (W.19.2x6.16) 245 - specify - 288 138.4 90 335d Wall Master Suite R-21 Wall (W.19.2x6.16) 335 - specify - 369 60.4 90 R-38 Roof 2 Master Suite R-38 Roof(R.38.2x14.16) 1386 N Wall Living/Dining/Kit/Entry R-21 Wall (W.19.2x6.16) 0 Right 394 73.0062 90 30d Wall Living/Dining/Kit/Entry R-21 Wall (W.19.2x6.16) at� 30 - specify - 410 26 90 75d Wall Living/Dining/Kit/Entry R-21 Wall (W.19.2x6.16) H� 75 - specify - 110 24 90 E Wall Living/Dining/Kit/Entry R-21 Wall (W.19.2x6.16)� 90 Front 553 282 90 120d Wall Living/Dining/Kit/Entry R-21 Wall (W.19.2x6.116 120 -specify - 425 0 90 S Wall Living/Dining/Kit/Entry R-21 Wall (W. 19.24.5.516) 180 Left 202 87.3976 90 245d Wall 2 Living/Dining/Kit/Entry R-21 Wall (W.19 x6.16) 245 - specify - 215 70.4 90 W Wall Living/Dining/KiVEntry R-21 Wall (t(1"t9.2x6.16) 270 Back 1047 553.4 90 300d Wall Living/Dining/Kit/Entry R-21 WaW 19.2x6.16) 0 Right 1710 45 90 R-38 Roof 3 Living/Dining/Kit/Entry R-38 1`46gf(R.38.2x14.16) 29.2 N Wall 2 2nd Floor R-2,1�W: all (W.19.2x6.16) 0 Right 162 8 90 30d Wall 2 2nd Floor R>2YWall (W.19.2x6.16) 30 - specify - 243 26 90 E Wall 2 2nd Floor ,s.' ER -21 Wall (W.19.2x6.16) 90 Front 126 18 90 120d Wall 2nd Floor R-21 Wall (W.19.2x6.16) 120 - specify - 171 30 90 S Wall 2 2nd Floor Age R-21 Wall (W.19.2x6.16) 180 Left 180 0 90 W Wall 2 2nd Floor ®" R-21 Wall (W.19.2x6.16) 270 Bads 185 72 90 300d Wall 2 2nd Floor R-21 Wall (W.19.2x6.16) 300 - specify - 198 20 90 R-38 Roof 4 2nd Floor ''� R-38 Roof(R.38.2x14.16) 903 65d Wall 2 Casita>�n R-21 Wall (W.19.2x6.16) 65 - specify - 230 36 90 155d Wall 2 Cas R-21 Wall (W.19.2x6.16) 155 - specify - 360 6 90 245d Wall 3 Caail a R-21 Wall (W.19.2x6.16) 245 - specify - 230 70.4 90 335d Wall 2 eXCasita R-21 Wall (W.19.2x6.16) 0 Right 360 50 90 R-38 Roof 5 twcasita R-38 Roof(R.38.2xl4.16) 652 Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CFIR-01062015-694 HERS Provider: Report Generated at: 2015-01-0815:58:49 CERTIF•E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Custom Res ation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xmi CF*F-01 Page 5 of 14 OPAQUE SURFACES — Cathedral Ceilings 01 01 02 03 04 05 07 06 07 08 09 10 11 Name Zone Type Orientatio n Area (ft) Skylight Area (ft2) Roof Rise (x in 12) Roof Pitch Roof Tilt (deg) Roof Reflectan ce Roof Emmittanc a Framin g Factor R-38 Roof Master Suite R-38 Roof(R.38.2x14.16)1 Back 9.1 9 0 0 0 0.1 0.85 1 0.1 ATTIC 01 02 03 04 05 06 07 Name Construction Roof Rise Roof Refb� nce Roof Emittance Radiant Barrier Cool Roof Attic Master Suite Attic Roof Cons Master Su 0 fQR1 0.85 No No Attic Living/Dining/Kit/E Attic Roof Cons Living/Di 0 A$ 0.1 0.85 No No Attic 2nd -Floor Attic Roof Cons 2nd Floor 0 0.1 A. 0.85 No No Attic Casita Attic Roof Cons Casita 0: 0.1 0.85 No No °0 Registration Number- ® Registration Date/Time: HERS Provider: CA Building Energy Efficiency Stan daarrds - 2013 Residential Compliance Report Version - CF1R-01062015-694 Report Generated at: 2015-01-0815:58:49 CERTIAE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE MOD Project Name: Custom Res Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xm1 CFOF-01 Page 6 of 14 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft2) U -factor SHGC Exterior Shading CC Window 155d Wall (- specify -155) - - 1 6.0 0.32 0.29 Insect Screen (default) Shower Window Window 155d Wall (- specify -155) - - 1 7.5 0.32 0.29 Insect Screen (default) AA Window 155d Wall (- specify -155) -- - 1 12.5 0.32 0.29 Insect Screen (default) W Window 155d Wall (- specify -155) - - 1 12.5 0.32 0.29 Insect Screen (default) X Window 155d Wall (- specify -155) - - 1 6.3 0.32 0.29 Insect Screen (default) Y Window 155d Wall (- specify -155) - � - 1 6.3 0.32 0.29 Insect Screen (default) Z Window 155d Wall (- specify -155) - 1 6.3 0.32 0.29 Insect Screen (default) BB Window 155d Wall (- specify -155) �= - 1 6.3 0.32 0.29 Insect Screen (default) 15 Window 245d Wall (- specify -245)1 17.3 8.0 1 138.4 0.32 0.29 Insect Screen (default) 152 Window 335d Wall (- specify -335) 6.8 8.0 1 54.4 0.32 0.29 Insect Screen (default) DD Window 335d Wall (- specify -335) 14 2.0 3.0 1 6.0 0.32 0.29 Insect Screen (default) Skylight AF Skylight R-38 Roof (Back -270) �� 1 9.0 0.59 0.39 9 Window N Wali (Right -0) - - 1 20.0 0.32 0.29 Insect Screen (default) L Window N Wall (Right -0) e�� 4.0 5.0 1 20.0 0.32 0.29 Insect Screen (default) M Window N Wall (Right -0) - - 1 6.0 0.32 0.29 Insect Screen (default) N Window N Wall (Right -0) �� - - 1 9.0 0.32 0.29 Insect Screen (default) P Window N Wall (Rightw01* - - - 1 9.0 0.32 0.29 Insect Screen (default) Q Window N Wall (Rightr0j 2.5 5.5 0.655 9.0 0.32 0.29 Insect Screen (default) J Window 30d Wall (- sacify -30) - - 1 26.0 0.32 0.29 Insect Screen (default) 17 Window 75d Wall,( -;`specify -75) 3.0 8.0 1 24.0 0.32 0.29 Insect Screen (default) B Window E ab -(Front -90) - - 1 32.0 0.32 0.29 Insect Screen (default) A Window $. ,Wall (Front -90) - - 1 96.0 0.32 0.29 Insect Screen (default) 1 Window *t Wall (Front -90) - - 1 40.0 0.95 0.49 Insect Screen (default) GG Window % E Wall (Front -90) - - 1 32.0 0.95 0.49 Insect Screen (default) EE Window ��' E Wall (Front -90) - - 1 32.0 0.32 0.29 Insect Screen (default) HH Window® E Wall (Front -90) -- - 1 9.0 0.32 0.29 Insect Screen (default) GG 2 Window`s E Wall (Front -90) - - 1 32.0 0.32 0.29 Insect Screen (default) C Window �°� E Wall (Front -90) -- - 19.0 0.32 0.29 Insect Screen (default) V Window S Wall (Left -180) 2.0 3.0 1 6.0 0.32 0.29 Insect Screen (default) .may Registration Number: ��� CA Building Energy Efficiency Standdaa'ds - 2013 Residential Compliance Registration Date/Time: Report Version - U111-01062015-694 HERS Provider: Report Generated at: 2015-01-0815:58:49 CERTIFOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE IIPOD Project Name: Custom Res Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xm1 CF*F-41 Page 7 of 14 U Window S Wall (Left -180) 5.0 5.0 1 25.0 0.32 0.29 Insect Screen (default) 11 Window S Wall (Left -180) 6.3 8.0 1.119 56.4 0.32 0.29 Insect Screen (default) 14 Window 245d Wall 2 (- specify -245) 8.8 8.0 1 70.4 0.32 0.29 Insect Screen (default) 13 Window W Wall (Back -270) 25.5 10.0 1 255.0 0.32 0.29 Insect Screen (default) J 2 Window W Wall (Back -270) 9.0 5.0 1 45.0 0.32 0.29 Insect Screen (default) 12 Window W Wall (Back -270) 15.0 8.0 1 120.0 0.32 0.29 Insect Screen (default) 112 Window W Wall (Back -270) - - 1 106.4 0.32 0.29 Insect Screen (default) R Window W Wall (Back -270) - - 1 9.0 0.32 0.29 Insect Screen (default) S Window W Wall (Back -270). - - 1 9.0 0.32 0.29 Insect Screen (default) T Window W Wall (Back -270) A� - 1 9.0 0.32 0.29 Insect Screen (default) K Window 300d Wall (Right -0) - 1 25.0 0.32 0.29 Insect Screen (default) 8 Window 300d Wall (Right -0) X2:5 8.0 1 20.0 0.32 0.29 Insect Screen (default) AD Window N Wall 2 (Right -0) - - 1 4.0 0.32 0.29 Insect Screen (default) AE Window N Wall 2 (Right -0) �� `� - - 1 4.0 0.32 0.29 Insect Screen (default) XX Window 30d Wall 2 (- specify -30) Ok- 1 6.0 0.32 0.29 Insect Screen (default) WW Window 30d Wall 2 (- specify -30) -0 - - 1 10.0 0.32 0.29 Insect Screen (default) W Window 30d Wall 2 (- specify -30) 4V - - 1 10.0 0.32 0.29 Insect Screen (default) TT Window E Wall 2 (Front -90) •�V - - 1 6.0 0.32 0.29 Insect Screen (default) SS Window E Wall 2 (Front -90) - - 1 6.0 0.32 0.29 Insect Screen (default) RR Window E Wall 2 (Front-90)w� - - 1 6.0 0.32 0.29 Insect Screen (default) UU Window 120d Wall 2 (- speci�fW 120) - - 1 30.0 0.32 0.29 Insect Screen (default) 41 Window W Wall 2 (Bagdkm 70) 3.0 8.0 1 24.0 0.32 0.29 Insect Screen (default) 42 Window W Wall 2R(B�ack-270) 6.0 8.0 1 48.0 0.32 0.29 Insect Screen (default) W Window 300d Wall 2i('7*specify -300) - - 1 6.0 0.32 0.29 Insect Screen (default) ZZ Window 300d �I}2 (- specify -300) - - 1 6.0 0.32 0.29 Insect Screen (default) AB Window 300ddrWall 2 (- specify -300) - - 1 4.0 0.32 0.29 Insect Screen (default) AC Window UO Wall 2 (- specify -300) - - 1 4.0 0.32 0.29 Insect Screen (default) NN Window °65d Wall 2 (- specify -65) - - 1 30.0 0.32 0.29 Insect Screen (default) PP Window ming' 65d Wall 2 (- specify -65) - - 1 6.0 0.32 0.29 Insect Screen (default) QQ Window ® 155d Wall 2 (-specify -155) - - 1 6.0 0.32 0.29 Insect Screen (default) 36 Window`+ 245d Wall 3 (- specify -245) 8.8 8.0 1 70.4 0.32 0.29 Insect Screen (default) JJ Window , �`r 335d Wall 2 (Right -0) 2.5 5.0 1 12.5 0.32 0.29 Insect Screen (default) KK Window 335d Wall 2 (Right -0) 2.5 5.0 1 12.5 1 0.32 1 0.29 1 Insect Screen (default) •®0 Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: Report Version - CF113-01062015-694 HERS Provider: Report Generated at: 2015-01-08 15:58:49 CERTIF JOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I OD CF F-01 Project 'JOE Custom Res Ca culation Date/Time: 15:55, Thu, Jan 08, 2015• Page 8 of 14 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xml LL Window 335d Wall 2 (Right -0) — — 1 12.5 0.32 0.29 Insect Screen (default) MM Window, 335d Wall 2 (Right -0) — — 1 12.5 0.32 0.29 Insect Screen (default) OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 1 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 15 8 0.1 8 8 0 02tt, 0 0 0 0 0 0 0 152 8 0.1 8 8 0- .0 0 0 .0 0 0 0 0 DD 8 0.1 8 8 0 Wo 0 0 0 0 0 0 0 L 5 0.1 5 5 0 "a° 0 0 0 0 0 0 0 0 Q 10 0.1 10 10 0 0 0 0 0 0 0 0 0 17' 6 0.1 6 6 Oj` 0 0 0 0 0 0 0 0 V 10 0.1 10.. 10 &J 0 0 0 0 0 0 0 0 U 14 0.1 14 14 '00 0 0 0 0 0 0 0 0 11 8 0.1 8 8 w_ -0 0 0 0 0 0 0 0 0 14 14 0.1 14 1411 0 0 0 0 0 0 0 0 0 13 20 0.1 20 �2 0 0 0 0 0 0 0 0 0 J2- 14 0.1 14 jii�14 0 0 0 0 0 0 0 0 0 12 14 0.1 14 O F 14 0 0 0 0 0 0 0 0 0 8 5 0.1 5.M`® 5 0 0 0 0 0 0 0 0 0 41 10 0.1`11� 10 0 0 0 0 0 0 0 0 0 42 10 0.1 -dfo 10 0 0 0 0 0 0 0 0 0 36 10 0.1 J 10 10 0 0 0 0 0 0 0 0 0 JJ 10 0.14 10 10 0 0 0 0 0 0 0 0 0 KK 10A� 10 10 0 0 0 0 0 0 0 0 0 ®V o® o®� Registration Number: �� CA Building Energy Efficiency Stand rds - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-01062015-694 HERS Provider:. Report Generated at: 2015-01-08 15:58:49 CERTIFO OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OOD Project Name: Custom Res Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xmi CF*F4M Page 9 of 14 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 02 �``� 03 04 05 Total Cavity Winter Design Name Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers Master Suite"® 982 107 None 1 No • Cavity/Frame: no insul. /2x4 Top Chrd Master Sate 413 36 2x4 Top Chord of Roof Truss @ 24 0 No Roof Deck., Wood Siding/sheathing/decking Attic Roof Cons Master Su Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) Living/Diring/Kit/Entry 2840 209 None 0 No • Inside Finish: Gypsum Board oVCasita Ceilings (below 56 None 1 No Cavity/Frame: R-9.1 /2x4 R-38 Roof(R.38.2xl4.16) attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. > Inside Finish: Gypsum Board • Cavity / Frame: R-38 / 2x4 Roof Deck. Wood Siding/sheathing/decking R-38 Roof(R.38.2xl4.16)1 Cathedral Ceilings Wood Framed Ceiling 04;• 2x4 @ 16 in. O.C. R38 0.041 Roofing: Light Roof (Asphalt Shingle) o®� a • Inside Finish: Gypsum Board Cavity/Frame: R-21 /2x6 Exterior Finish: Wood R-21 Wall (W.19.24.16) Exterior Walls Wood Framed Wall ,,��r 2x6 @ 16&fi§�O.C. R 21 • 0.066 Siding/sheathing/decking • • Cavity/Frame: no insul. /2x4 Top Chrd' 2x4 Top Chord'o�f Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Living/Di Attic Roofs Wood Framed Ceiling 40n O.C. none 0.644 Roofing., Light Roof (Asphalt Shingle) • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 ToplRord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons 2nd Floor Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing., Light Roof (Asphalt Shingle) • Cavity/Frame: no insul. /2x4 Top Chrd 24 Top Chord of Roof Truss @ 24 •- Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Casita Attic Roofs Wood Framed Ceiling y in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS► 01 02 �``� 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated Covered Slab Master Suite"® 982 107 None 1 No Hard Surface Slab Master Sate 413 36 None 0 No Covered Slab 2 Living/Dirn/KiVEntry 902 96 None 1 No Hard Surface Slab 2 Living/Diring/Kit/Entry 2840 209 None 0 No Covered Slab 3 oVCasita 384 56 None 1 No Hard Surface Slab 3 Casita 268 60 None 0 No o®®d' Registration Number: ��� CA Building Energy Efficiency Stando ar'ds - 2013 Residential Compliance Registration Date/Time: Report Version - CF111-01062015-694 HERS Provider: Report Generated at: 2015-01-08 15:58:49 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Custom Res ation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xml CFOF-41 Page 10 of 14 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Required Not Required Not Required — WATER HEATING SYSTEMS 01 02 03 04'W9 05 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/2 DHW Pipe Insulation, All Lines DHW Heater 1 2 .0% DHW Sys 3 - 1/1 DHW Pipe Insulation, All Lines( DHW Heater 3 1 .0% W.<a WATER HEATERS¢�W 01 02 03 04'W9 05 06 07 08 Name Heater Element Type Tank Type Tank -Volume ,, (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage - w 75 0.65 65000-Btu/hr 0 0 DHW Heater 3 Natural Gas Small Storage 'klw 75 0.65 65000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION A0 01 02 03 04 05 06 07 Name Pipe Insulation e®� �® Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1-1/2— DHW Sys 3-1/1 s� Registration Number:��® Registration Date/Time: CA Building Energy Efficiency Standards�- 2013 Residential Compliance Report Version - CF1R-01062015-694 HERS Provider: Report Generated at: 2015-01-08 15:58:49 CERTIOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Custom Res Ca culation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xml CF F-01 Page 11 of 14 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Cooling Component 1:Heating Component 1:Air Other Heating and Cooling Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Distribution System 1:HVAC Fan 1:1 System 13.1 16.3 Not Zonal Single Speed Cooling Component 2:Heating Component 2:Air Other Heating and Cooling Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 Distribution System 2:HVAC Fan 2:1 System 13 16 Not Zonal Single Speed Cooling Component 3:Heating Component 3:Air Other Heating and Cooling Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 Distribution System 3:HVAC Fan 3:1 System Cooling Component 4: Heating Component 4:Air Distribution System 4:HVAC Fan 4:1 Other Heating and Cooling System Heating Component 4 (i'�Cooling Component 4 HVAC Fan 4 Air Distribution System 4 HVAC - HEATING UNIT TYPES w 02 01 02 - 03 Name AV Type Efficiency Heating Component 1 CntrlFurnace-- Fuel -fired central furnace 80 AFUE Heating Component 2 CntrlFu ace - Fuel -fired central furnace 80 AFUE Heating Component 3 Cntdlurnace - Fuel -fired central furnace 80 AFUE Heating Component 4 GiatdNrnace - Fuel -fired central furnace 80 AFUE rV HVAC - COOLING UNIT TYPES - 01 02 A ��' 03 04 05 06 07 , Name System Type ®� Efficiency EER SEER Zonally Controlled Multi -speed Compressor HERS Verification Cooling Component 1 SplitAirCond �� 13 16 Not Zonal Single Speed Cooling Component 2 SplitAirCond 13.1 16.3 Not Zonal Single Speed Cooling Component 3 SplitAirCond i 13.1 16.3 Not Zonal Single Speed Cooling Component 4 SplitAirCond 13 16 Not Zonal Single Speed V Registration Number: A& Pk; Building Energy Efficiency Stand,: s - 2013 Residential Compliance Registration Date/Time: Report Version - CF1R-01062015-694 HERS Provider: Report Generated at: 2015-01-0815:58:49 CERTIFW OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD Project Name: Custom Res Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xm1 CF*' F-01 Page 12 of 14 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctslnAll Sealed and tested 8 Attic None Air Distribution System 1 -hers -dist Air Distribution System 2 DuctslnAll Sealed and tested 8 Attic None Air Distribution System 2 -hers -dist Air Distribution System 3 DuctslnAll Sealed and tested 8 Attic None Air Distribution System 3 -hers -dist Air Distribution System 4 DuctslnAll Sealed and tested 8 �► & Attic None Air Distribution System . 4 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04.,,CQ 05 .06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified -Duct L'cation Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1 -hers -dist Required 6.0 %Ltequired Not Required Not Required Not Required. Air Distribution System 2 -hers -dist Required 6.0 `� Required Not Required Not Required Not Required — Air Distribution System 3 -hers -dist Required 6.0 Required Not Required Not Required . Not Required — Air Distribution System 4 -hers -dist Required 6.0 `� Required Not Required Not Required Not Required — HVAC -FAN SYSTEMS W 01�,,°02 03 04 Name`s Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single',�'Speed PSC Furnace Fan 0.58 HVAC fan 2 Si@glgle Speed PSC Furnace Fan 0.58. HVAC Fan 3 R VSingle Speed PSC Furnace Fan 0.58 HVAC Fan 4 �"�Single Speed PSC Furnace Fan 0.58 HVAC FAN SYSTEMS - HERS VERIFICATION %vl 01 ir 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) V ®®! Registration Number: ��a'r'� CA Building Energy Efficiency StandVds - 2013 Residential Compliance Registration Date/Time: Report Version - CF111-01062015-694 HERS Provider: Report Generated at: 2015-01-08 15:58:49 CERTIE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD Project Name: Custom Res Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xml CF&F-01 Page 13 of 14 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 164.42 0.25 Default 0 Required 0 CERTIF0E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD CFOF-61 Project Name: Custom Res Ccu lation Date/Time: 15:55, Thu, Jan 08, 2015 Page 14 of 14 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xm1 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ,( Tim Scott Company: Signature Date: Scott Design and Title 24, Inc, 1/8/2015 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/StatePalIm Desert, CA 92211 Phone: (&,0) 200-4780 X RESPONSIBLE PERSON'S DECLARATION STATEMENT "A , I certify the following under penalty of perjury, under the laws of the State of California: o�t� 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for�th�e building design identified on this Certificate of Compliance. 2. I certify that the energy features and performance specifications identified on this Certificate ot,,Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. ' 3. The building design features or system design features identified on this Certificate of Copance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency:,for approval with this building permit application. Responsible Designer Name: �pqg� Responsible Designer Signature: " AAM Company: v Date Signed: STRACTS, Inc. Address: License: 550 S. Oleander Rd. �® City/State/Zip: Phone: Palm Springs, CA 92264 �, (760) 636-8951 o® V o®0 Registration Number: ��� CA Building Energy Efficiency Stan`da"a ds - 2013 Residential Compliance Registration Date/Time: Report Version - CF111-01062015-694 HERS Provider: Report Generated at: 2015-01-0815:58:49 9 • 0 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Custom Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/8/2015 Project Address Lot 66D, The Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,692 Addition n/a # of Units 1 INSULATION Construction Type Cavi Area ft) Special Features Status Roof Wood Framed Attic R38 2,970 New Wall Wood Framed R 21 7,282 New Slab Unheated Slab -on -Grade - no insulation 5,789 Perim = 564' New Demising Wood Framed - no insulation 1,970 New FENESTRATION Orientation Area(ft) T Total Area: 1.769 Glazin Percentage: 26.4%1New/Altered U -Fac SHGC Overhang Sidefins Average U -Factor: 0.35 Exterior Shades Status Skylight 9.0 0.590 0.39 none none None New Left (SE) 69.7 0.320 0.29 none none Bug Screen New Rear (SW 138.4 0.320 0.29 8.0 none Bug Screen New Right (NIM 60.4 0.320 0.29 8.0 none Bug Screen New Right (N) 102.0 0.320 0.29 none none Bug Screen New Right (N) 40.0 0.320 0.29 5.0 none Bug Screen New Right (N) 34.0 0.320 0.29 10.0 none Bug Screen New Right (NE) 52.0 0.320 0.29 none none Bug Screen New Front (E) 24.0 0.320 0.29 6.0 none Bug Screen New Front (E) 228.0 0.320 0.29 none none Bug Screen New Front (E) 72.0 0.950 0.49 none none Bug Screen New Left (S) 6.0 0.320 0.29 10.0 none Bug Screen New Left (S) 25.0 0.320 0.29 14.0 none Bug Screen New Left (S) 56.4 0.320 0.29 8.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 3 Central Furnace 80% AFUE Split Air Conditioner 16.3 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.3 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status HVAC 1 Ducted Ducted Conditioned 8.0 New HVAC 2,3 & 4 Ducted Ducted Conditioned 8.0 New HVAC 5 Ducted Ducted Conditioned 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Small Storage Gas 75 0.65 All Pipes Ins New 1 Small Storage Gas 75 0.65 All Pipes Ins New EnerqvPro 6.4 by Enert qySoft User Number: 6712 Run Code: 2015-01-08T16:08:08 ID: Pae 17 of 42 • • • RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Custom Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/8/2015 Project Address Lot 66D, The Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,692 Addition n/a # of Units 1 INSULATION Construction Type Area Cavi(ft) Special Features Status FENESTRATION Orientation Area ft2 Total Area: 1,769 Glazing Percentage: 26.4 % U -Fac SHGC Overhang Sidefins New/Altered Average U -Factor: 0.35 Exterior Shades Status Rear (Sl9 70.4 0.320 0.29 14.0 none Bug Screen New Rear (w) 255.0 0.320 0.29 20.0 none Bug Screen New Rear (Kq 165.0 0.320 0.29 14.0 none Bug Screen New Rear (w) 133.4 0.320 0.29 none none Bug Screen New Front (SE) 30.0 0.320 0.29 none none Bug Screen New Rear (Vloq 72.0 0.320 0.29 10.0 none Bug Screen New Rear (NIM 20.0 0.320 0.29 none none Bug Screen New Front (NE) 36.0 0.320 0.29 none none Bug Screen New Rear (SK9 70.4 0.320 0.29 10.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status HVAC 6 Ducted Ducted Conditioned 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 6.4 by EnemySoft User Number., 6712 Run Code: 2015-01-08716:08:08 ID: Pae 18 of 42 4 4 4 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Date Custom Residence 111812015 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 110.6(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §110.6(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111(a). 110.7: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 110.8(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -2R Form. §110.8(i): The thermal emittance and solar reflectance values of the cool roofing material -meets the requirements of §110.8(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50.0 a : Minimum R-30 R-19 for Alterations insulation in wood -frame ceiling orequivalent U -factor. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150.0(c): Minimum R-13 insulation in 2x4 wood -frame wall R-19 in 2x6 orequivalent U -factor. *§150.0(d): Minimum R-19 insulation in raised wood -frame floor ore uivalent U -factor. §150.0(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form. 150.0 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150.0(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. §150.0(q) Fenestration Products. Fenestration separating conditioned space from unconditioned space or outdoors shall meet the requirements of either Item 1 or 2 below: 1. Fenestration, including skylight products, must have a maximum U -factor of 0.58. 2. The weighted average U -factor of all fenestration, including skylight products, shall not exceed 0.58. EXCEPTION to Section 150.0(q)1: Up to 10 square feet of fenestration area or 0.5 percent of the Conditioned Floor Area, whichever is reater, is exempt from the maximum U -factor requirement. 150.0 r Solar Ready Buildings. Shall meet the requirements of Section 110.10 applicable to the building project. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150.0 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §110.3(c)5. §110.5: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150.0(h): Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA. §150.00): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 0.2 c . §150.00)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation havinq an installed thermal resistance of R-12 or greater. §150.00)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. EnergyPro 6.4 by EnergySoft User Number. 6712 ID: Page 19 of 42 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Custom Residence 111812015 §150.00)2A: All domestic hot water system piping conditions listed below, whether buried or unburied, must be insulated per TABLE 120.3-A. i. The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. ii. All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. iii. All piping associated with a domestic hot water recirculation system regardless of the pipe diameter. iv. Piping from the heating source to storage tank or between tanks. v. Piping buried below grade. vi. All hot water pipes from the heating source to the kitchen fixtures. §150.00)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 120.3-A. §150.0(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §150.00)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. §150.0(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minimum installed level of R-6 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150.0(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150.0(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150.0(m)7: Exhaust fans stems have back draft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150.0(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. IF 150.0 m 10: Flexible ducts cannot have porous inner cores. §150.0(n)1: Systems using gas or propane water heaters, whether tank or on -demand, to serve individual dwelling units shall include all the following components : A. A 120V electrical receptacle that is within 3 feet from the water heater and accessible to the water heater with no obstructions; B. A Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; C. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assist, D. A gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §110.4(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 110.4(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ro rammed to run only durin off-peak electric demand periods. §150.0(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150.0 . Residential Lighting Measures - easures:§150.0(k)1A: §1 50.0(k)lA:Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with Section 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B as applicable. 150.0 k 1C: The wattage of permanently installed luminaires shall be determined asspecified by §130.0(c). 150.0 k 1 D: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency - 20 kHz. §150.0(k)1 E: Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no more than five watts of power per luminaire or exhaust fan as determined in accordance with Section 130.0(c). Night lights shall not be required to be controlled by vacancy sensors. EnergyPro 6.4 by EnergySoft User Number: 6712 ID: Page 20 of 42 C MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Custom Residence Date 111812015 150.0 k 1 F: Lighting integral to exhaust fans in rooms other than kitchens shall meet the applicable requirements of §150.0(k). 150.0(k)2: All switching devices and controls shall meet the requirements of §150.0(k)2. §150.0(k)3: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft' or 100 watts for dwelling units larger than 2,500 ftZ may be exempt from the 50 percent high efficacy requirement when all lighting in the kitchen is controlled in accordance with the applicable provisions in Section 150.0(k)2, and is also controlled by vacancy sensors or dimmers. §150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: Lighting installed in bathrooms shall meet the following requirements: A. A minimum of one high efficacy luminaire shall be installed in each bathroom; and B. All other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. EXCEPTION 1: Luminaires in closets less than 70 square feet. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site. §150.0(k)8: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150.0(k)9A: For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours iii. Controlled by one of the following methods: a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with Section 110.9; meets the Installation Certification requirements in Section 130.4; meets the requirements for an EMCS in Section 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. §150.0(k)9A: For low-rise multi -family residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with Section 150.0(k)9A; or ii. Shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by Section 150.0(k)9B or Section 150.0(k)9D shall comply with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. §150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in Sections 110.9 130.0 130.2 130.4 140.7 and 141.0. §150.0(k)10: Internally illuminated address signs shall comply with Section 140.8; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to § 1 30.0 d . §150.0(k)l1: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130. 1, 130.4, 140.6, and 141.0. §1 50.0(k)l 2A. In a low-rise multi -family residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. §150.0(k)12B. In a low-rise multi -family residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6, and 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. EnergyPro 6.4 by EnergySoft User Number., 6712 ID: Page 21 of 42 r HVAC .SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence Date 1/8/2015 System Name HVAC 1 Floor Area 1,395 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 928 18,015 Return Vented Lighting 0 Return Air Ducts 341 Return Fan 01 Ventilation 0 0 Supply Fan . 0 Supply Air Ducts 341 TOTAL SYSTEM LOAD _ 18,696 1 COIL HTG. Latent CFM 2,872 432 0 0 2,872 PEAK Heating System Sensible Output per System 89,000 19,119 Total Output Btuh 89,000 -Output(Bt uh/s ft 63.8 263 Cooling System 0 Output per System 58,000 0 Total Output Btuh 58,000 0 Total Output ons 4.8 263 Total Output Btuh/s ft 41.6 Total Output s ft/Ton 288.6 19,645 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANB760/58CVXl10 39,503 7,142 89,000 Airflow cfm/s ft 1.43 Total Adjusted System Output 39,503 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 7,142 89,000 Aug 3 PM Jan 1 AM Airflow cfm/Ton 413.8 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 114 OF 114 OF Heating Coil Supply Fan 2,000 cfm 114 o F ROOM 72 OF ri COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside AirAr 0 cfm 70/59°F 70/59°F 52/51 OF 52/51 OF u� c Cooling Coil Supply Fan 2,000 cfm 50.7% 52 / 51 OF -- --- ME ROOM 70/59°F Energ Pro 6.4 by EneigySoft User Number: 6712 Run Code: 2015.01-08716:08:08 ID: Page 22 of 42 �ACYSTEM HEATING AND.000LING LOADS SUMMARY Project Name ustom Residence Date 1/8/2015 Floor Area 3,742 System Name HVAC 2,3 & 4 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 COIL COOLING PEAK COIL HTG. CFM Sensible Latent CFM Total Room Loads 2,879 56,852 7,704 1,283 Return Vented Lighting 0 Return Air Ducts 1,075 Return Fan 01 Ventilation F o 0 0 0 Supply Fan 0 Supply Air Ducts 1,075 TOTAL SYSTEM LOAD 59,002 7,704 PEAK Heating System Sensible Output perSystem 51,000 53,988 Total Output Btuh 153,000 Output Btuh/s tt 40.9 743 Cooling System 0 Output perSystem 35,5001 0 Total Output Btuh 106,500 0 Total Output Tons 8.9 743 Total Output Btuh/s tt 28.5 Total Output s ft/Ton 421.6 155,474 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 3,600 Carrier 24ANB736/58CVX070 73,237 Total Adjusted System Output 73,237 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 12,516 153,000 12,516 153,000 Aug 3 PM Jan 1 AM Airflow cfm/s ft 0.96 Airflow cfmfTon 405.6 Outside Air % 0.0% Outside Air cfmis tt 0.00 IN Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air Ar, 10 0 cfm 72 OF 72 OF 112 OF 112 OF 43" '_,�-d 10 43' Heating Coil Supply Fan 3,600 cfmWN o 112 F ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 70/59°F 70/59°F 51 /50°F 51 /50°F 15 C Cooling Coil Supply Fan 3,600 cfm' 50.8% 51 / 50 OF ROOM 70/59°F Energ Pro 6.4 by Energ Soft, User Number: 6712 RunCode: 2015-01-08716:08:08 ID: Page 23 of 42 4 14 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name , ustom Residence Date 1/8/2015 System Name HVAC 5 Floor Area 903 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 598 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 51,000 12,195 1,859 237 10,033 Total Output Btuh 51,000 0 Output Btuh/s ft 56.5 231 138 Cooling System 01 0 Output per System 35,500 0 0 0 0 Total Output Btuh 35,500 0 231 12,656 1,859 0 Total Output ons 3.0 138 Total Output Btuh/s ft 39.3 Total Output s ft/Ton 305.2 10,309 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24ANB736/58CVX070 24,949 3,406 51,000 Airflow cfm/ s ft 1.33 Airflow cfm/Ton 405.6 Outside Air % 0.0% Total Adjusted System Output 24,949 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 3,406 Aug 3P ml 51,000 Outside Air cfm/s tt0.00 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 112 OF 112 OF Heating Coil Supply Fan 1,200 cfm 112 o F • ROOM IRE 72 of COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 70 / 58 OF 70/58°F 51/50°F 51/50°F Cooling Coil Supply Fan 51 / 50 OF 1,200 cfm — ---- -- r 48.9% ROOM 70 / 58 °F Energ Pro 6.4 by Energ Soft User Number: 6712 Run Code: 201501-08716:08:08 ID: Page 24 of 42 4 HVAC SYSTEM HEATING AND COOLING LOADS' SUMMARY Project Name ustom Residence Date 1/8/2015 System Name HVAC 6 Floor Area 652 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 487 9,630 Return Vented Lighting 0 Return Air Ducts 182 Return Fan 01 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 182 TOTAL SYSTEM LOAD 9,994 COIL HTG. Latent CFM 1,342 196 0 0 1,342 PEAK Heating System Sensible Output per System 51,000 12,410 Total Output Btuh 51,000 Output Btuh/s ft 78.2 171 Cooling System 0 Output per System 23,5001 0 Total Output Btuh 23,500 0 Total Output ons 2.0 171 Total Output Btuh/s ft 36.0 Total Output s ft/Ton 332.9 12,752 Air System CFM per System 800 HVAC EOUIPMENT SELECTION Airflow cfm 800 Carrier 24ANB724/58CVX070 16,197 2,671 51,000 Airflow cfm/s ft 1.23 Airflow cfm/Ton 408.5 Outside Air % -0.0% Total Adjusted System Output 16,197 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 2,671 Aug 3P M 51,000 Outside Air cfm/s 0.00 ft Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 132 OF 132 OF i Heating Coil Supply Fan o 800 cfm 132 F ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 70 / 59 OF 70/59°F 51/50°F 51/50°F c Cooling Coil Supply Fan 800 cfm 50.2 Bio 51 / 50 OF ------ ROOM 70 / 58 OF EnergyPro 6.4 by Energ Soft User Number. 6712 Run Code: 2015-01-08T16:08:08 ID: Page 25 of 42 • • ROOM LOAD SUMMARY Project Name Date Custom Residence 1/8/2015 System Name Floor Area HVAC 1 1,395 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Master Suite Master Suite 1 928 18,015 2,872 928 18,015 2,872 4321 19,119 PAGE TOTAL TOTAL ' 928 18,015 2,872 432 19,119 928 18,015 2,872 432 19,119 Total includes ventilation load for zonal systems. EnemyPro 6.4 by EnemySoft User Number.- 6712 Run Code: 2015-01-08716:08:08 ID: Page 26 of 42 • • • ROOM LOAD SUMMARY Project Name Date Custom Residence 1/8/2015 System Name Floor Area HVAC 5 903 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM Sensible I Latent CFM I Sensible I Latent CFM I Sensible 2nd Floor 12nd Floor 1 1 1 5981 12,1951 1,859 5981 12,1951 1,859 2371 10,033 PAGE TOTAL TOTAL' 598 12,195 1,8591 237 10,033 598 12,195 1,859 237 10,033 Total includes ventilation load for zonal systems. EnergyPro 6.4 by EnerqySoft User Number: 6712 RunCode: 2015-01-08T16:08:08 ID: Page 28 of 42 • 0 ROOM LOAD SUMMARY Project Name Date Custom Residence 1/8/2015 System Name Floor Area HVAC 6 652 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM I Sensible Casita I Casita I 1 1 4871 9,6301 1,342 4871 9,6301 1,342 1961 12,410 PAGE TOTAL TOTAL 487 9,630 1,342 196 12,410 487 9,630 1,342 196 12,410 Total includes ventilation load for zonal systems. EnergyPro 6.4 by EnemySoft User Number: 6712 RunCode: 2015-01-08716:08:08 ID: Page 29 of 42 • • L ROOM HEATING PEAK LOADS Project Name Date Custom Residence 1/8/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Time of Peak Jan 1 AM Floor Area 1,395.0 ft2 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF Conduction Area U -Value AT *F Btu/hr R-38 Roof(R.38.2x14.16) 1,386.0 X 0.0260 X 46 = 1,658 Skylight 9.0 X 0.5900 X 46 = 244 R-21 Wall (W. 19.2x6.16) 1,268.5 X 0.0690 X 46 0 4,026 Double non-metal tinted 262.5 X 0.3200 X 46 = 3,864 Slab -On -Grade Perim = 143.0 X 0.7300 X 46 = 4,802 'R-0 Interior Wall 650.0 X 0.3560 X 0 = 0 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X X X = X X = X X = X X = X X _ X X = X X = X X = X X X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 14,594 Infiltration:[ 1.00 X 1.064 X 1,395 X 11.50 X 0.346 /60] X 46 = 4,525 Schedule Air Sensible Fraction Area Ceiling Height ACH AT TOTAL HOURLY HEAT LOSS FOR ROOM 19,119 EnergyPro 6.4 by EnergySoft User Number: 6712 Run Code: 2015-01-08716:08:08 ID: Page 30 of 42 • • • ROOM HEATING PEAK LOADS Project Name Custom Residence Date 1/8/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Dining/Kit/Entry Floor Area 3,742.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Outdoor Dry Bulb Temperature Jan 1 AM 26 OF Conduction Area U -Value 29.2 X 0.0260 3,904.8 X 0.0690 1,089.2 X 0.3200 72.0 X 0.9500 perim = 305.0 X 0.7300 650.0 X 0.3560 X X X X X X X X X X X X X X X X X X X X X ' X X X X through an interior surface to another room X 3,742 X 11.50 X 0.346 Area Ceiling Height ACH AT X X X X X X X X X X X X X X, X X X X X X X X X X X X X X X X X /60] *F 46 = 46 c 46 = 46 0 46 = 0 = = = = _ = _ = = = o = = o = = = = c = = Page Total X 46 AT Btu/hr 35 12,394 16,033 3,146 10,242 0 41,850 = 12,138 R-38 Roof(R.38.2x14.16) R-21 Wall (W.19.2x6.16) Double non-metal tinted Entry Door Slab -On -Grade 'R-0 Interior Wall Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 53,988 EnergyPro 6.4 by EnergySoR User Number. 6712 RunCode: 2015-01-08T16:08:08 ID: Page 31 of 42 • • ROOM HEATING PEAK LOADS Project Name Custom Residence Date 1/8/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Floor Area 903.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value 903.0 X 0.0260 1,091.0 X 0.0690 174.0 X 0.3200 310.0 X 0.3560 X X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to another room X 903 X 8.90 X 0.447 Area Ceiling Height ACH X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F Btu/hr 46 = 1,080 46 = 3,463 46 = 2,561 0 0 0 = c = = = = = = = = = = = = _ = = = = = = = = = Page Total 7,104 /60] X 46 _ 2,929 AT R-38 Roof(R.38.2x14.16) R-21 Wall (W.19.2x6.16) Double non-metal tinted 'R-0 Interior Wall Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 10,033 EnergyPro 6.4 by EnergySoft User Number: 6712 RunCode: 2015-01-08716:08:08 ID: Page 32 of 42 • C ROOM HEATING PEAK LOADS Project Name Custom Residence Date 1/8/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Floor Area Indoor Dry Bulb Temperature Casita 652.0 ft2 72 °F Time of Peak Outdoor Dry Bulb Temperature Jan 1 AM 26 OF Conduction Area U -Value 652.0 X 0.0260 1,017.6 X 0.0690 162.4 X 0.3200 perim = 116.0 X 0.7300 360.0 X 0.3560 X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to another room X 652 X 10.00 X 0.398 Area Ceiling Height ACH AT X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X /60] *F 46 = 46 = 46 = 46 = 0 = = = = = = = _ _ c = = = = = = = = = = = = = = = = = Page Total 1 X 46 AT Btu/hr 780 3,230 2,391 3,895 0 10,295 = 2,115 R-38 Roof(R.38.2x14.16) R-21 Wall (W. 19.2x6.16) Double non-metal tinted Slab -On -Grade "R-0 Interior Wall Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 12,410 EnergyPro 6.4 by EnergySoft User Number: 6712 Run Code: 2015-01-08T16:08:08 to: Page 33 of 42 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 1/8/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,395.0 ft-' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF Opaque Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) 'R-0 Interior Wall Orientation (NE) I (SK91 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,386.0 0.0260 56.0 250.0 0.0690 30.8 560.3 0.0690 28.8 149.6 0.0690 31.9 308.6 0.0690 29.0 650.0 0.3560 0.0 20.9 0.0 6.3 20.9 0.0 6.3 20.9 0.0 6.3 20.9 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Skylight AF Cc Shower Window AA W X Y Z BB Orientation (M (SE) (SE) (SE) (SE) (SE) (SE) (SE) (SE) Shaded Area X X X X X X X X GLF 26.7+ 17.2 + 17.2 + 17.2 + 17.2 + 17.2 + 17.2 + 17.2 + 17.21+1 Unshaded Area X X X X X X X X1 GLF = = = = = = = - 0.0X 9.0x 79.5= 0.0 6.0 20.9 0.0 7.5 20.9 0.0 12.5 20.9 0.0 12.5 20.9 0.0 6.3 20.9 0.0 6.3 20.9 0.0 6.3 20.9 0.0 6.3 20.9 Page Total Btu/hr Z018 531 1,113 329 618 0 4, 608 Btu/hr 716 125 157 261 261 132 132 132 132 Internal Gain Btu/hr Occupants 4 2 Occupants X 245 Btuh/occ. = 1,025 Equipment 1,395 Floor Area X 0.50 yy/ggft = 2,381 Infiltration: 1.084 X 1.27 X 70.34 X 42 = 3,979 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,015 Latent Gain Occupants 4 2 Occupants X 155 Btuh/occ. Infiltration: 4.771 X 1.27 X 70.34 X 0.00523 = Air Sensible CFM ELA AW AL HOURLY LATENT HEAT GAIN FOR ROOM Btu/hr 649 1 2,2231 I tnergyPrO 6.4 by EneMySoft User Number: 6712 Run Code: 2015-01-08716:08:08 ID: Page 34 of 42 1 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 1/8/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,395.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation . Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation . Area GLF Area GLF Btu/hr 15 (SVt9 138.4 X 17.2 + 0.0 X 24.8 = 2,375 15 (NVt9 0.0 X 17.2 + 54.4 X 26.5 = 1,441 DD (NVt0 0.0 X 17.2 + 6.0 X 26.5 = 159 X + X = X + X = X + X _ X + X = X + X = X + X = Page Total 1 3,97 Internal Gain Btu/hr Occupants 4 2 Occupants X 245 Btuh/occ. = 1,025 Equipment 1,395 Floor Area X 0.50 w/sgft = 2,381 Infiltration: 1.064 X 1.27 X 70.34 X 42 = 3,979 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,015 Latent Gain Btuihr Occupants 4 2 Occupants X 155 Btuh/occ. = 649 Infiltration: 4,771 X 1.27 X 70.34 X 0.00523 = 2,223 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 649 EnemyPro 6.4 by EneMySoft User Number: 6712 Run Code: 2015-01-08716:08:08 ID: Page 35 of 42 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 1/8/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Dining/Kit/Entry Outdoor Dry Bulb Temperature 112 OF Floor Area 3,742. 0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Ooaoue Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) Orientation (tM (N) (NE) (E) (E) (SE) (S) (SK9 (W Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 29.21 0.0260 56.0 1,986.0 0.0690 23.0 384.0 0.0690 27.0 86.0 0.0690 31.7 271.0 0.0690 33.0 425.0 0.0690 31.7 114.6 0.0690 26.0 144.6 0.0690 31.9 493.6 0.0690 33.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fpnpstratinn 9 L M N P Q J 17 B Orientation (N) (N) (N) (N) (N) (N) (NE) (E) (E) Page Total 617 929 318 1,124 7,291 Shaded Area 0.0 X 0.0 X 0.0 X 0.0 X 0.0 X 0.0 X 0.0 X 9.3 X 0.0 X GLF 17.2 17.2 17.2 17.2 17.2 17.2 17.2 17.2 17.2 Unshaded Area GLF + 20.0 X 17.2 + 20.0 X 17.2 + 6.0 X 17.2 + 9.0 X 17.2 + 9.0 X 17.2 + 9.0 X 17.2 + 26.0 X 23.4 + 14.7 X 31.7 + 32.0 X 34.4 Page Total = = = = = = = = = Btulhr 343 343 103 154 154 154 608 626 1,100 3,58 Internal Gain Btu/hr Occupants 11.2 Occupants X 245 Btuh/occ. = 2 Equipment 3,742 Floor Area X 0.50 w/sgft = Infiltration: 1.064 X 1.27 X 188.69 X 42 10,i Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 56,8521 Latent Gain Btu/hr Occupants 11.2 Occupants X 155 Btuh/occ. = 1,740 Infiltration: 4,771 X 1.27 X 188.69 X 0.00523 = 5,964 Air Sensible CFM ELA AW HEAT GAIN FOR ROOM 1 i tnergyrro6.a by tnergyson user Number. 6712 Run Coale: 2015-01-08716:08:08 ID: Page 36 of 42 I V • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 1/8/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Dining/Kit/Entry Outdoor Dry Bulb Temperature 112 OF Floor Area 3,742. 0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranae: 34 OF Opaque Surfaces -R-0 Interior Wall Orientation Area U -Factor CLTD' 650.0 X 0.3560 X 0.0 = X X = X X = X X = X X = X X = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) FPnPStrnfinn A 1 GG EE HH GG C v U Oripntatinn (E) (E) (E) (E) (E) (E) (E) (S) (S) Btu/hr 01 Shaded Area Unshaded GLF Area X 17.2 + 96.0 X 37.2 + 40.0 X 37.2 + 32.0 X 17.2 + 32.0 X 17.2 + 9.0 X 17.2 + 32.0 X 17.2 + 9.0 X 17.2 + 0.0 X 1 17.2 + 0.0 GLF X 34.4 X 66.3 X 66.3 X 34.4 X 34.4 X 34.4 X 34.4 X 17.2 X 17.2 Page Total = = = = = = = = = Btu/hr 0.0 3,300 0.0 2,651 0.0 2,121 0.0 1,100 0.0 309 0.0 1,100 0.0 309 6.0 103 25.01 429 11,423 Internal Gain Btu/hr Occupants 11.2 Occupants X 245 Btuh/occ. = 2,750 Equipment 3,742 Floor Area X 0.50 w/sgft = 6,386 Infiltration: 1.064 X 1.27 X 188.69 X, 42 = 10,673 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 56,852 Latent Gain Btu/hr Occupants 11.2 Occupants X 155 Btuh/occ. = 1,740 Infiltration: 4,771 X 1.27 X 188.69 X 0.00523 = 5,964 Air Sensible CFM ELA AW AL HOURLY LATENT HEAT GAIN FOR ROOM 1.740 n E, • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 1/8/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Dining/Kit/Entry Outdoor Dry Bulb Temperature 112 OF Floor Area 3,742. 0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranqe: 34 OF Surfaces Orientation Area U -Factor CLTD' X X = X X X X = X X = X X = X X = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) FPn PC}rnfinn 11 14 13 J 12 11 R S T nriantntinn Shaded Unshaded Area X X X X X X X X GLF + + + + + + + + Area X X X X X X X X GLF = c = = = = = = 56.4 17.2 0.0 17.2 70.4 17.2 0.0 24.8 255.0 17.2 0.0 34.4 45.0 17.2 0.0 34.4 120.0X 17.2+ 0.0x 34.4= 0.0 17.2 106.4 34.4 0.0 17.2 9.0 34.4 0.0 17.2 9.0 34.4 0.0 17.2 9.0 34.4 Page Total Btu/hr 968 1,208 4,376 772 2,059 3,658 309 309 Internal Gain Btu/hr Occupants 11.2 Occupants X 245 Btuh/occ. = 2,750 Equipment 3,742 Floor Area ' X 0.50 w/sgft = 6,386 Infiltration: 1.064 X 1.27 X 188:69 X 42 = 10,673 Air Sensible CFM El A AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 56.8521 Latent Gain Btu/hr Occupants 11.2 Occupants X 155 Btuh/occ. = 1,740 Infiltration: 4,771 X 1.27 X 188.69 X 0.00523 = 5,964 Air Sensible CFM ELA AW AL HOURLY LATENT HEAT GAIN FOR ROOM 1.74 I EnergyPro 6.4 by EnerpySoff User Number. 6712 Run Code: 2015-01-08716:08:08 ID: Page 38 of 42 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name711812015 ate Custom Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Dining/Kit/Entry Outdoor Dry Bulb Temperature 112 OF Floor Area 3,742.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr K (N) 0.0 X 17.2 + 25.0 X 17.2 = 429 8 (N) 0.0 X 17.2 + 20.0 X 17.2 = 343 X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 772 Internal Gain Btu/hr Occupants 11.2 Occupants X 245 Btuh/occ. = 2,750 Equipment 3,742 Floor Area X 0.50 w/sgft = 6,386 Infiltration: 1.064 X 1.27 X 188.69 X 42 = 10,673 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 56,852 Latent Gain Btu/hr Occupants 11.2 Occupants X 155 Btuh/occ. = 1,740 Infiltration: 4,771 X 1.27 X 188.69 X 0.00523 = 5,964 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,745 EnemyPro 6.4 by EneMySoft User Number: 6712 RunCode: 2015-01-08T16:08:08 ID: Page 39 of 42 11 • • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 1 1/8/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 903.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF Onanue Surfar_pc R-38 Roor(R.38.2x14.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) 'R-0 Interior Wall Orientation (N) (NE) (E) (SE) (S) W (NKK Area X X X X X X X X X U -Factor X X X X X X X • X X CLTDt = = = = = = a = = 903.0 0.0260 56.0 154.0 0.0690 23.0 217.0 0.0690 27.0 108.0 0.0690 33.0 141.0 0.0690 31.7 180.0 0.0690 26.0 113.0 0.0690 33.0 178.0 0.0690 31.2 310.0 0.3560 0.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fenestration AD AE WW vv TT SS RR UU Orientation (N) (N) (NE) (NE) (NE) (E) (E) (E) (SE) Page Total Btu/hr 1,315 244 404 246 308 323 1 3831 Shaded Area GLF X 17.2 X 17.2 X 17.2 X 17.2 X 17.2 X 17.2 X 17.2 X 17.2 XI 17.2 Unshaded Area + 4.0 X + 4.0 X GLF 17.2 = 17.2 = 23.4 = 23.4 = 23.4 = 34.4 = 34.4 = 34.4 = 24.6 = Page Total Btu/hr 0.0 69 0.0 69 0.0 + 6.0 X 140 0.0 + + + 10.0 X X X 234 0.0 10.0 234 0.0 6.0 206 0.0 + + 6.0 X X 206 0.0 6.0 206 0.0 + 30.0 X 737 2,101 n Btu/hr 2.7 Occupants X 245 Btuh/occ. - 664 903 Floor Area X 0.50 W/sgft = 1,541 Infiltration: 1.064 X 1.27 X 45.53 X 42 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,195 Latent Gain Btu/hr Occupants 2 7 Occupants X 155 Btuh/occ. = 420 Infiltration: 4.771 X 1.27 X 45,53 X 0.00523 = 1,439 Air Sensible CFM ELA AW • • P', RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 1 1/8/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 903.0 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 41 (M 23.7X 17.2+ 0.3X 34.4= 417 42 W 47.4 X 17.2 + 0.6 X 34.4 = 834 YY (NVL9 0.0 X 17.2 + 6.0 X 29.1 = 175 ZZ (NVtq 0.0 X 17.2 + 6.0 X 29.1 = 175 AB (NVt9 0.0 X 17.2 + 4.0 X 29.1 = 116 AC (NVt9 0.0 X 17.2 + 4.0 X 29.1 = 116 X + X = X + X = X +1 X = Page Total 1,833 Internal Gain Btu/hr Occupants 2.7 Occupants X 1 245 Btuh/occ. = 664 Equipment 903 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 1.27 X 45.53 X 42 = 2,576 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,195 Latent Gain Btu/hr Occupants 2 7 Occupants X 155 Btuh/occ. = 420 Infiltration: 4.771 X 1.27 X 45.53 X 0.00523 = 1,439 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 420 Ene Pro 6.4 by EnerqySoft User Number. 6712 Run Code: 2015-01-08716:08:08 ID: Page 41 o/42 • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 1 1/8/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name Casita Outdoor Dry Bulb Temperature 112 OF Floor Area 652.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (IM 652.0 X 0.0260 X 56.0 = 949 R-21 Wall (W.19.2x6.16) (NE) 194.0 X 0.0690 X 30.8 = 412 R-21 Wall (W. 19.2x6.16) (SE) 354.0 X 0.0690 X 28.8 = 703 R-21 Wall (W. 19.2x6.16) (SVIO 159.6 X 0.0690 X 31.9 = 351 R-21 Wall (W.19.2x6.16) (N) 310.0 X 0.0690 X 23.0 = 492 *R-0 Interior Wall 360.0 X 0.3560 X 0.0 = 0 X X = X X = X X = Page Total 2,907 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr NN (NE) 0.0 X 17.2 + 30.0 X 30.0 = 900 PP (NE) 0.0 X 17.2 + 6.0 X 30.0 = 180 QQ (SE) 0.0 X 17.2 + 6.0 X 20.9 = 125 36 (SIM 70.4 X 17.2 + 0.0 X 24.8 = 1,208 JJ (N) 0.0 X 17.2 + 12.5 X 17.2 = 215 KK (N) 0.0X 17.2+ 12.5X 17.2= 215 LL (N) 0.0 X 17.2 + 12.5 X 17.2 = 215 MM (N) 0.0 X 17.2 + 12.5 X 17.2 = 215 X + X = Page Total 3,271 Internal Gain Btu/hr Occupants 2 0 Occupants X 245 Btuh/occ. = 479 Equipment 652 Floor Area X 0.50 w/sgft = 1,1,13 Infiltration: 1.064 X 1.27 X 32.88 X 42 = 1,860 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,630 Latent Gain Btu/hr Occupants 2 0 Occupants X 155 Btuh/occ. = 303 Infiltration: 4,771 X 1.27 X 32.88 X 0.00523 = 1,039 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 303 Ene Pro 6.4 by EnemySoft User Number- 6712 Run Code: 2015-01-08716:08:08 ID: Pa - e 42 of 42 �J CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD i Project Name: Custom Res Calculation DatefTime: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xm1 CF1 R -PRF -01 Page 1 of 14 GENERAL INFORMATION 01 Project Name Custom Res 02 Calculation Description Title 24 Analysis s p is n f E iclr. 03 Project Location Lot 66D, The Hideaway BUILDING & SAFETY DEP . '`.' This compliance analysis is valid only for permit applications through December 31 2014 APP OVED 04 City La Quinta 05 Standards Version Compliance 2014 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3bl (694) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.4 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 6692 15 Number of Zones 4 16 Slab Area (FT2) 5789 17 Number of Stories 2 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (FT2) N/A 21 Glazing Percentage (%) 26.4% COMPLIANCE RESULTS 01 Building Complies with Computer;Performance w 02 This building incorporates features that require field testing and/orvenfiication by'a certifQ HERS-iater,unde� t � s p is n f E iclr. 03 -r _ . w r -..::� This building incorporates orie or more�SpecialVF%atures`shown below - BUILDING & SAFETY DEP . '`.' This compliance analysis is valid only for permit applications through December 31 2014 APP OVED ENERGY USE SUMMARY FOR CONST UCTION 04 05 06 07 08 Energy Use Standard (kTDV/ft2-yr) Design Proposed Design C rEWffc Mar in Per Space Heating 2.87 2.56 0.31 10.8% Space Cooling 88.35 84.16 4.19 r 4.7% IAQ Ventilation 1.10 1.10 0.00 0.0% Water Heating 4.05 5.28 -1.23 -30.4% Photovoltaic Offset — 0.00 0.00 — Compliance Energy Total 96.37 93.10 3.27 3.4% NE D i i FEB 0 J 2015 a Registration Number: 215-N0012901A-000000000-0000 Registration Date/Time: 2015-01-08 19:58:36 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01062015-694 CITY vP LA QUINTAReort Generated at: 2015-01-08 15:59:10 COMMUNITY DEVELOPMENT CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Description: Title 24 Analysis Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Input File Name: Hideaway Lot 66D-STRACTS-15.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cathedral Ceiling • Window overhangs and/or fins • Exposed slab floor in conditioned zone CFI R -PRF -01 Page 2 of 14 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High Quality Insulation Installation (QII) • IAQ mechanical ventilation Cooling System Verifications: — None — HVAC Distribution System Verifications: Duct Sealing , rVerified low -leakage ducts located entirely in conditioned space Domestic Hot Water System Verifications: •r— None— lv'a. _a.*.r VA'. P�4+ . 5 i e._ '3,.• ENERGY DESIGN RATING Q This is the sum of the annual TDV ener °ciinsum tiori forenergy use'com onents included in they erformance'com liance a roach`fo` tl4e Standard Design Building Ener Budget) and the annual 9Y�,, {P 9Y P P�. P �.PPb . _ 9 9 ( 9Y 9 ) TDV energy consumption for lighting and components not regulated-by,Title.24 Pact 6 (such'as"domestic appliances=and`consumerelectronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use F f ';Energy; Design Ratmgy MarginPercent Improvement ae Total Energy (kTDV/f2-yr)* 131.60 3.27 2.5% • includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Number of Water Cooling Systems Heating Systems Custom Res 6692 1 12 4 2 Registration Number: 215-N0012901A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2015-01-08 19:58:36 Report Version - CF1R-01062015-694 GI I Y Ur v1 k.,ivIIN BUILDING ®&®SAF��®T P A P 6— H FOR CONSTRUCTION DATE BY Report Generated at: 2015-01-08 15:59:10 inc. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xml CFI R -PRF -01 .Page 3 of 14 ZONE INFORMATION .01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Master Suite Conditioned HVAC 11 1395 11.5 DHW Sys 1 Living/Dining/Kit/Entry Conditioned HVAC 2,3 & 42 3742 11.5 DHW Sys 1 2nd Floor Conditioned HVAC 53 903 8.9 DHW Sys 1 Casita 'Conditioned HVAC 64 652 10 DHW Sys 3 • n� �.. . 'a v � ., + �+! - � .. y.. .�.. � 1. R: iµ � - . •' - ^ �' - !f \ 4' �:,:, � 4 t K" � ar`, � . � �, �. �* ., r i t f •.,.t ,� •waw z. r • � ` ,., .^ ,' . .. - ` • t' 16 { e. t- tet. s , r A v.,:� . r ° t • c i ,� .,/ .= , a rr g•.1�+1:.,. is F ' - .,� , _ ��y .. �' � r, � �'.•:.. } aha '"�j*rt <•�* .,'i � - ° .. - - .. - .4y s. d "' , -'y*.r ,�? yr kt .� ,r. `� .•• F a - 2 r 1 r M - _ s t� ,`� •' i, ''fit .:� rr' ti rya t •, a.� :•.�.j r `r�a7' �.,- e� ,� ai �. - �A ]�' 5 ' >.. i q�[i �,a •*,� � s. - a : 2j a,P4 . CITY OF LA QUiNTA BUILDING & SAFETY DEPT. PROVED FOR CONSTRUCTION' "PPR VE DATE BY Registration Number: 215-N0012901A-000000000-0000 Registration Date/Time: - 2015-01-0819:58:36 HERS Provider: CaICERTS inc. , CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01062015-694 Report Generated at: 2015-01-08 15:59:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xml CFI R -PRF -01 Page 4 of 14 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window Area (ft2) Tilt (deg) 65d Wall Master Suite R-21 Wall (W.19.2x6.16) 65 - specify - 250 0 90 155d Wall Master Suite R-21 Wall (W.19.2x6.16) 155 - specify - 624 63.7 90 245d Wall Master Suite R-21 Wall (W.19.2x6.16) 245 - specify - 288 138.4 90 335d Wall Master Suite R-21 Wall (W.19.2x6.16) 335 - specify - 369 60.4 90 R-38 Roof 2 Master Suite R-38 Roof(R.38.2x14.16) 1386 N Wall Living/Dining/Kit/Entry R-21 Wall (W.19.2x6.16) 0 Right 394 73.0062 90 30d Wall Living/Dining/Kit/Entry R-21 Wall (W.19.2x6.16) 30 - specify - 410 26 90 75d Wall Living/Dining/Kit/Entry R-21 Wall (W.19.2x6.16) 75 - specify - 110 24 90 E Wall Living/Dining/Kit/Entry R-21 Wall (W.19.2x6.16) 90 Front 553 282 90 120d Wall Living/Dining/KittEntry R-21 Wall (W.19.2x6.16) 120 - specify - 425 0 90 S Wall Living/Dining/Kit/Entry R-21 Wall (W.19.2x6.16) 180 Left 202 87.3976 90 245d Wall 2 I- dying/Dining/KiUEntry "sem"' t -R-21kWall (1N:192x61..t6)- 1245 - specify - 215 70.4 90 W Wall Living/Dining/KiUEntry{ ,rA R=21 Wall (W79.2x6.16) 270 V Back 1047 553.4 90 300d Wall .iving/DningKiUEntr � R21 Wall,(V1F99.2(6.16)1 '.,,i O' ., W.�AlRight-1 1710 45 90 R-38 Roof 3 NLiving/Dining/Kit)Entry`" '' ;'' R-38 Roof(R,38 2x14:16)*^"�';£`� 4 29.2 N Wall 2 -.2nd Floor R-21 Wall (W.19.2x6.16) 0 Right 162 8 90 30d Wall 2 2nd Floor R-21 Wall (W.19.2x6.16) 30 - specify - 243 26 90 E Wall 2 2nd Floor R-21 Wall (W.19.2x6.16) 90 Front 126 18 90 120d Wall 2 2nd Floor R-21 Wall (W.19.2x6.16) 120 - specify - 171 30 90 S Wall 2 2nd Floor R-21 Wall (W.19.2x6.16) 180 Left 180 0 90 W Wall 2 2nd Floor R-21 Wall (W.19.2x6.16) 270 Back 185 72 90 300d Wall 2 R-38 Roof 4 2nd Floor 2nd Floor R-21 Wall (W.19.2x6.16) R-38 Roof(R.38.2x14.16) 300 - specify - 198 0 65d Wall 2 Casita R-21 Wall (W.19.2x6.16) 65 - specify -3 E T. 9tl 155d Wall 2 Casita R-21 Wall (W.19.2x6.16) 155 - specify - 6 9 245d Wall 3 Casita R-21 Wall (W.19.2x6.16) 245 -specify - 30, 9 335d Wall 2 Casita R-21 Wall (W.19.2x6.16) 0 Right 0 9 R-38 Roof 5 Casita R-38 Roof(R.38.2x14.16) 652 DATE__"' --- Registration Number: 215-N0012901A-000000000-0000 Registration Date/Time: 2015-01-08 19:58:36 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-01062015-694 Report Generated at: 2015-01-08 15:59:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD - Project Name: Custom Res Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xmi CF1 R -PRF -01 Page 5 of 14 + OPAQUE SURFACES — Cathedral Ceilings 01 01 02 03 04 05 07 06 07 08 09 10' 11 Name f Zone " Type Orientatio n Area (ft) Skylight Area (ft2) Roof Rise (x in 12) Roof Pitch Roof Tilt (deg) Roof Reflectan ce Roof Emmittanc a Framin g Factor R-38 Roof • Master Suite R-38 Roof(R.38.2x14.16)1 Back 9.1 9 -0 0 0 0.1 0.85 0.1 ATTIC 01 02 03 04 05 06 07 Name Construction • Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof • ,. Attic Master Suite Attic Roof Cons Master Su 0 ; - 0.1 '0.85 No No 'Attic Living/Dining/Kit/E Attic Roof Cons Living/Di ' �0: 0.1 : 0.85 No _ No .. Attic 2nd Floor Attic Roof Cons 2nd Floor 0 �•,' = f"•',-: 0.1 0.85 _ ' No " t" No Attic Casita _ Attic Roof Cons Casita " ' 0 `, • 0.1 0.85 ` ` t ` No No 1. a _ • C • • ` � " � .. �y��# 1` °�'•"f k � FF � r �;~ � \- � 1. • • "• Y Y • f . .. 1 r '+4 r �` v. ' a ;'i - ,+ �+`-+r +' r'at�s;. ♦ � , �" Nc _� rF-.� zA � r. •. - - i. .� v4. �„''^ F,' X�c •; 1 F. x.r • �, t � ��' h e--,. i F- ,h }:. �a r a '' -� Y•,T � ,••. A'� r . 4 i ~ t \ l •�. i yT .J y j tom. _ C'� ` t'N a ,. ;• y 'S �` - '� ; - } \ 1 tl•Y' : ; ! •qi l : • ,.. • a...� a L .. ~ � r Vie. y' • � �y y , i _ - �. - - - y ...+ _ • Y.. � .rr�. ' � .j' - Registration Number: 215-N0012901A-000000000-0000 Registration Date/Time: 2015-01-08 19:58:36 4 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-01062015-694 X S inc. Report Generated at: 2015-01-08 15:59:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xml CF1 R -PRF -01 Page 6 of 14 WINDOWS . 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Multipli Height (ft) er Area (ft2) U -factor SHGC Exterior Shading CC Window 155d Wall (- specify -155) - - 1 6.0 0.32 0.29 Insect Screen (default) Shower Window Window 155d Wall (- specify -155) - - 1 7.5 0.32 0.29 Insect Screen (default) AA Window 155d Wall (- specify -155) - - 1 12.5 0.32 0.29 Insect Screen (default) W Window 155d Wall (- specify -155) - - 1 12.5 0.32 0.29 Insect Screen (default) X Window 155d Wall (- specify -155) - - 1 6.3 0.32 0.29 Insect Screen (default) Y Window 155d Wall (- specify -155) - - 1 6.3 0.32 0.29 Insect Screen (default) Z Window 155d Wall (- specify -155) - - 1 6.3 0.32 0.29 Insect Screen (default) BB Window 155d Wall (- specify -155) - - 1 6.3 0.32 0.29 Insect Screen (default) 15 Window 245d Wall (- specify -245) 17.3 8.0 1 138.4 0.32 0.29 Insect Screen (default) 152 Window 335d Wall (- specify -335) 6.8 8.0 1 54.4 0.32 0.29 Insect Screen (default) DD Window 335d Wall(yspecify 335) w� 2 0 ,r *� 3.0 1 6.0 1 0.32 0.29 Insect Screen (default) Skylight AF Skylight �: Y R=38 Roof (Ba6k-270) , " ."-{N v +t If 1 9.0 0.59 0.39 9 Window` , f Wall (Right -0),` ` `° -`' 20.0 0.32 0.29 Insect Screen (default) L Window ,?f` f/� N Wall_(Rig"ht 0),->i ,tiC,-`<< 4.0., SA.1,� 20.0 0.32 0.29 Insect Screen (default) M Window ON Wall (Right -0) - - 1 6.0 0.32 0.29 Insect Screen (default) N Window N Wall (Right -0) - - 1 9.0 0.32 0.29 Insect Screen (default) P Window N Wall (Right -0) - - 1 9.0 0.32 0.29 Insect Screen (default) Q Window N Wall (Right -0) 2.5 5.5 0.655 9.0 0.32 0.29 Insect Screen (default) J Window 30d Wall (- specify -30) - - 1 26.0 0.32 0.29 Insect Screen (default) 17 Window 75d Wall (- specify -75) 3.0 8.0 1 24.0 0.32 0.29 Insect Screen (default) B Window E Wall (Front -90) - - 1 32.0 0.32 0.29 Insect Screen (default) A Window E Wall (Front -90) - - 1 96.0 0.32 0.29 Insect Screen (default) 1 Window E Wall (Front -90) - - 1 40.0 0.95 0.49 Insect Screen (default) GG Window E Wall (Front -90) - - 1 32.0 fault) . EE Window E Wall (Front -90) - - 1 130013 (d fault) HH Window E Wall (Front -90) - - 1 9. LM &0� EiY���n (d fault) GG 2 Window E Wall (Front -90) - - 1 32.0 0. Green (d fault) C Window E Wall (Front -90) - - 1 9.0 0R� reen (d fault) V Window S Wall (Left -180) 2.0 3.0 1 6.0 0.32 0.29 Insect Screen ( fault) Registration Number: 215-N0012901A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2015-01-08 19:58:36 Report Version - CF1R-01062015-694 DATE gy FIEIK Rrevider ai ERTS inc. Report Generated at: 2015-01-08 15:59:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xm1 CFI R -PRF -01 Page 7 of 14 U Window S Wall (Left -180) 5.0 5.0 1 25.0 0.32 0.29 Insect Screen (default) 11 Window S Wall (Left -180) 6.3 8.0 1.119 56.4 0.32 0.29 Insect Screen (default) 14 Window 245d Wall 2 (- specify -245) 8.8 8.0 1 70.4 0.32 0.29 Insect Screen (default) 13 Window W Wall (Back -270) 25.5 10.0 1 255.0 0.32 0.29 Insect Screen (default) J 2 Window W Wall (Back -270) 9.0 5.0 1 45.0 0.32 0.29 Insect Screen (default) 12 Window W Wall (Back -270) 15.0 8.0 1 120.0 0.32 0.29 Insect Screen (default) 112 Window W Wall (Back -270) - - 1 106.4 0.32 0.29 Insect Screen (default) R Window W Wall (Back -270) - - 1 9.0 0.32 0.29 Insect Screen (default) S Window W Wall (Back -270) - - 1 9.0 0.32 0.29 Insect Screen (default) T Window W Wall (Back -270) - - 1 9.0 0.32 0.29 Insect Screen (default) K Window 300d Wall (Right -0) - - 1 25.0 0.32 0.29 Insect Screen (default) 8 Window 300d Wall (Right -0) 2.5 8.0 1 20.0 0.32 0.29 Insect Screen (default) AD Window N Wall 2 (Right -0) - - 1 4.0 0.32 0.29 Insect Screen (default) AE Window N Wall 2 (Right -0) - - 1 4.0 0.32 0.29 Insect Screen (default) XX Window 30d Wall 2 (;specify 30)x- 1 6.0 0.32 0.29 Insect Screen (default) WW Window 5 "' ` _�30d .Wali 2_(- specify, 30) � " ` �`= 1 10.0 0.32 0.29 Insect Screen (default) W Window r J 30d WaIP2 (-specify'.=30)x,; Ali' ?'4' :Y'£ - �_. y -�1 0 10.0 0.32 0.29 Insect Screen (default) TT Window E WaW2 (Front 90) Y ` " t " Ei 1? 6.0 0.32 0.29 Insect Screen default SS Window E Wall 2 (Front -90) - - 1 6.0 0.32 0.29 Insect Screen (default) RR Window E Wall 2 (Front -90) - - 1 6.0 0.32 0.29 Insect Screen (default) UU Window 120d Wall 2 (- specify -120) - - 1 30.0 0.32 0.29 Insect Screen (default) 41 Window W Wall 2 (Back -270) 3.0 8.0 1 24.0 0.32 0.29 Insect Screen (default) 42 Window W Wall 2 (Back -270) 6.0 8.0 1 48.0 0.32 0.29 Insect Screen (default) W Window 300d Wall 2 (- specify -300) - - 1 6.0 0.32 0.29 Insect Screen (default) ZZ Window 300d Wall 2 (- specify -300) - - 1 6.0 0.32 0.29 Insect Screen (default) AB Window 300d Wall 2 (- specify -300) - - 1 4.0 0.32 0.29 Insect Screen (default) AC Window 300d Wall 2 (- specify -300) - - 1 4.0 0.32 0.29 Insect Screen (default) NN PP Window Window 65d Wall 2 (- specify -65) 65d Wall 2 (- specify -65) - - - - 1 1 3 .0 .0b.12 &-2F 0. AspJJcrp*de It) t c of It) QQ Window 155d Wall 2 (- specify -155) - - 1 .0 t (def ult) Window 245d Wall 3 (- specify -245) 8.8 8.0 1 7P.4 C)Vk36 c en (def ult) JJ Window 335d Wall 2 (Right -0) 2.5 5.0 1 1 .5 G'TC1 en (def ult) KK Window 335d Wall 2 (Right -0) 2.5 5.0 1 12.5 0.32 1 0.29 1 Insect Screen (de ult) Registration Number: 215-N0012901A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2015-01-08 19:58:36 Report Version - MR -01062015-694 UA L BY ro TS ink. Report Generated at: 2015-01-08 15:59:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: Custom Res Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Page 8 of 14 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xml LL Window 335d Wall 2 (Right -0) — — 1 12.5 0.32 0.29 Insect Screen (default) MM Window 335d Wall 2 (Right -0) — — 1 12.5 0.32 0.29 Insect Screen (default) OVERHANGS AND FINS 01 02 03 04 05 06 07 1 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 15 8 0.1 8 8 0 0 0 0 0 0 0 0 0 152 8 0.1 8 8 0 0 0 0 0 0 0 0 0 DD 8 0.1 8 8 0 0 0 0 0 0 0 0 0 L 5 0.1 5 5 0 0 0 0 0 0 0 0 0 Q 10 0.11 10 10 0 0 0 0 0 0 0 0 0 17 6 0.1 6 6 0 0 0 0 0 0 0 0 0 V X10 0.1 , , '-10 -Y-X100 .rTIRT.0 P- r7 -9T A.- 1tt: 0 0 0 0 0 0 0 Up% 14 0 1 14 }} 14 4. sti" 0:'°p' 1`#aft "iyq 0° " 0 0 Y.:R ' 0 0 0 0 0 11 8 fl p F 8 ;t :8 p � - P �?`a �ar^ , :� �`U � Q> 0 0 0 0 0 1414" .6 0�1 t"!•s]4L° 14 "�ZOfti< 0i.r� 0' ?fie 0 0 0 0 0 0 13 20 0.1 t 20 20 0 0 0 0 0 0 0 0 0 J2 14 0.1r 14 14 0 0 0 0 0 0 0 1 0 0 12 14 0.1' 14 14 0 0 0 0 0 0 0 0 0 8 5 0.1 5 5 0 0 0 0 0 0 0 0 0 41 10 0.1 10 10 0 0 0 0 0 0 0 0 0 42 10 0.1 10 10 0 0 0 0 0 0 0 0 0 36 10 0.1 10 10 0 0 0 0 .0 0 0 0 0 JJ 10 0.1 10 10 0 0 0 0 0 0 0 0 0 KK 10 0.1 10 10 0 0 0 0 0 0 0 0 0 CITY OF LA QUINTA BUILDINGG& SAF\ET. � TY DEP FOR CONSTRUCTION DATE BY Registration Number: 215-N0012901A-000000000-0000 Registration Date/Time: 2015-01-08 19:58:36 ------LA1&EJRTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-01062015-694 Report Generated at: 2015-01-08 15:59:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xm1 CF1 R -PRF -01 Page 9 of 14 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 02 03 04 05 Total Cavity Winter Design Name Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers Master Suite 982 107 None 1 No • Cavity/ Frame: no insul. / 2x4 Top Chrd Master Suite 413 36 2x4 Top Chord of Roof Truss @ 24 0 No Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Master Su Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) Living/Dining/Kit/Entry 2840 209 0 Ilko • Inside Finish: Gypsum Board Casita Ceilings (below 560 Cavity/Frame: R-9.1 /2x4 R-38 Roof(R.38.2xl4.16) attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-38 / 2x4 • Roof Deck: Wood Siding/sheathing/decking R-38 Roof(R.38.2xl4.16)1 Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.041 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board i Cavity / Frame: R-21 / 2x6 • Exterior Finish: Wood R-21 Wall (W.19.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking lY -� Truss.@ 24 Cavity/ Frame: no insul. / 2x4 Top Chrd Roof Deck: Wood Siding/sheathing/decking • �:1 r 2x4 ,Top Chord of�Roof Attic Roof Cons Living/Di r Attic Roofs F, Wood Framed,Ceiling t y . 'in O.C: tf. "t none 0.644 Roofing: Light Roof (Asphalt Shingle) 7Er� Truss C tl of �* ' ' Cavity/ Frame: no insul. /2x4 Top Chrd Roof Deck. Wood Siding/sheathing/decking Attic Roof Cons 2nd Floor Attic Roofs Jam, Wood Framed Ceiling 2x4 To~ Roof @'24. in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof Cons Casita Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated Covered Slab Master Suite 982 107 None 1 No Hard Surface Slab Master Suite 413 36 None 0 No Covered Slab 2 Living/Dining/Kit/Entry 902 96 one 1 No Hard Surface Slab 2 Living/Dining/Kit/Entry 2840 209 0 Ilko Covered Slab 3 Casita 384 560 Hard Surface Slab 3 Casita 268 60 None qo Registration Number: 215-NO0129OIA-000000000-0000 Registration Date/Time: 2015-01-08 19:58:36 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01062015-694 FOR CONSTRUCTION DATE HERS ProvidBy Cal ERTS inc. epo Z013 -0t-0 59:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Description: Title 24 Analysis Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Input File Name: Hideaway Lot 66D-STRACTS-15.xml CF1 R -PRF -01 Page 10 of 14 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Required Not Required Not Required — WATER HEATING SYSTEMS 01 02 03 04 05 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/2 DHW Pipe Insulation, All Lines DHW Heater 1 2 .0% DHW Sys 3 - 1/1 DHW Pipe Insulation, All Lines DHW Heater 3 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type_._Tank„Type.,, Compact Distribution Tank Volume (gal) K Energy Factor or w ,Efficlency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas a Small'Storage ��A75n — r a ri. X0.65 65000 Btu/hr 0 0 DHW Heater 3 Natural Gasp jj' " ; }`= r N R it Small Storage y'�,. 6 75>`0 V. XQ'.. 65 SKr• h • :.il, 65000-Btu/hr 0 0 'yr,�'�� �i'.� ��"'�. t.i�' �' �*`LL, f� �•ew?so-`. �,,-��`,, ��q*b..a�"a' i4�' i+ �'a• WATER HEATING - HERS VERIFICATION_ y r;I ? 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1-1/2 — — — — — — DHW Sys 3 - 1/1 — — — — — — h Registration Number: 215-NO0129OIA-000000000-0000 Registration Date/Time: 2015-01-08 19:58:36 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-01062015-694 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED 'FOR CONSTRUCTION DATE BY HERS Provider: CaICERTS inc. Report Generated at: 2015-01-08 15:59:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Daterrime: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xml CF1 R -PRF -01 Page 11 of 14 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 - SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Cooling Component 1:11eating Component 1:Air Other Heating and Cooling Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Distribution System 1:11VAC Fan 1:1 System 16 Not Zonal Single Speed Cooling Component 2 Cooling Component 2:11eating Component 2:Air Other Heating and Cooling Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 Distribution System 2:HVAC Fan 2:1 System 16.3 Not Zonal Single Speed Cooling Component 4 Cooling Component 3:Heating Component 3:Air Other Heating and Cooling Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 Distribution System 3:HVAC Fan 3:1 System Cooling Component 4:Heating Component 4:Air Other Heating and Cooling Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution System 4 Distribution System 4:HVAC Fan 4:1 System HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Heating Component 19ntrlFurnace Fuel-fired.central=furnace 80 AFUE Heating Component 2' lF 6w�' / -v _CntrlF, a ec *-, Fuel -fled central Tfurnace SO AFUE Heating Component.3. , #3tt I;. f lbntrlFurnace- Fuel-fire'd.central f6mace 80 AFUE Heating Component 41Lt,«,.� t s `S. CntrlFurnace Fuel -fired cenUal- rnace l ' a a ys. .:. ' ....i:F 80 AFUE 9.1 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Name System Type Efficiency EER SEER Zonally Controlled Multi -speed Compressor HERS Verification Cooling Component 1 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component 2 SplitAirCond 13.1 16.3 Not Zonal Single Speed Cooling Component 3 SplitAirCond 13.1 16.3 Not Zonal Single Speed Cooling Component 4 SplitAirCond 13 16 Not Zonal r-- _-Siogie3peed CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY Registration Number: 215-N0012901A-000000000-0000 Registration Date/Time: 2015-01-08 19:58:36 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01062015-694 Report Generated at: 2015-01-08 15:59:10 CERTIFICATE OF COMPLIANCE. RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Custom Res Calculation Date/Time: 15:55, Thu, Jan 08, 2015 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xml CFI R -PRF -01 Page 12 of 14 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctslnAll Sealed and tested 8 Attic None Air Distribution System 1 -hers -dist Air Distribution System 2 DuctslnAll Sealed and tested ' 8 Attic None Air Distribution System 2 -hers -dist Air Distribution System 3 DuctslnAll Sealed and tested 8 Attic None • Air Distribution System 3 -hers -dist Air Distribution System 4 DuctslnAli Sealed and tested 8 Attic None Air Distribution System 4 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01`' ` 02 03 04 OS - O6 07' 08 Name Duct Leakage ` Verification ti ' Duct Leakage 'Target (%) Verified Duct Location Verified Duct Design Buried " Ducts Deeply Buried Ducts Low -leakage Air Handler •' Air Distribution System 1 -hers -dist 4,0PRequired �...= 6:0 ,_ .. Required, Not Required Not Required Not Required — Air Distribution System 2 -hers -dist y {�' Requirred 6 0y?Required x �. , 1NotRequired Not Required Not Required Air Distribution System 3 -hers -dist Requi fed a?' 6 0 + ' I wredY Ae_R�ed�Ntt Required Not Required — Air Distribution System 4 -hers -dist v6c0'-" \Regwred gNot„k d - Require Not Required Not Required — HVAC -FAN SYSTEMS 01 02 III QW129 R, 94F=Pit DI=RT 01 02. 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 III QW129 R, 94F=Pit DI=RT Name Verified Fan Watt Draw Registration Number: 215-NO012901A-000000000-0000 - Registration Date/Time: 2015-01-08 19:58:36 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01062015-694 i •e ■ I IL 1%-W v vv FOR CONSTRUCTION DATE BY HERS Provider: CaICERTS inc. Report Generated at: 2015-01-08 15:59:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Custom Res - Calculation Date/Time- 15:55, Thu, Jan 08, 2015 - Page 13 of 14 Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 66D-STRACTS-15.xml IAQ (Indoor Air Quality) FANS 01 02 03, 04 05 06• - Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) v HERS Verification SFam IAQVentRpt 164.42 0.25 Default 0 Required ,. 3 .. - `� � . i _ of � .. - � � . w• ;ley. �� '�^ e .. � S c.• J. .. Jr 4 a • _ { , •' y. - �� .RL• Fi ins�'(s:: ka^ti. �*^ .. �. � - _:.(•. � r . ' , r • ! '• 1 y t .. v + f. ♦ tk •.rrtS" t / • `Y -...'4 ` -a •i y - - � t ,' r 4�' - ..... ^. ri. r, .. •„ ' CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-01062015-694 Report Generated at: 2015-01-0815:59:10 k~ CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD ` Project Name: Custom Res - - Calculation Date/Time: 15:55, Thu, Jan 08; 2015 _ Calculation Description: Title 24 Analysis ` Input File Name: Hideaway Lot 66D-STRACTS-15.xm1 4 CF1 R -PRF -01 :..Page 14 of 14- 7 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete.. Documentation Author Name: Documentation Author Signature: I �.., n Tim Scott Company: Signature Date: ' • '. w Scott Design and Title 24; Inc. f + i 2015-01-08 19:58:36 ` Address: : CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 (760) 2004780 RESPONSIBLE PERSON'S DECLARATION STATEMENT; - I certify the following under penalty of perjury, under the laws of the State of California 1. t am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.1. 2. '1 certify that the energy features and performance specifications identified on this Certificate of Compliance'conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of,_. Regulations. 3. The building design features or system•design features identified.on-this. Certificate of.Complianceare.consistent,with the information provided on other applicable compliance documents, `+ tworksheets, calculations, plans and "sp ifications subm ed to the enforcement'agJ.enhcy forapproval with this building permit application. Responsible Designer Name: �: ygmf � Ftesponsible Designer Signature: ,z Tim Scott F�rg , y . _ Company: , r ti + ;, - Date'Signed: _" Scott Design and Title 24,-Inc.�,�'`�_� 2015-01-08.19.58:36 Address: License: u r 77085 Michigan Drive na City/State/Zip. Phone: • _ M •' y ,, Desert, CA 92211 80r, (760) 200-47Palm * =' M inc. �.., n , L.11 V I TA N . ' r & SAFETY DEPT. Digitally signed by Ca10ERTS..This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Pro1 ur fEinformation. NSTRUCTION LE. BY Registration Number: 215-N0012901A-000000000-0000 `' Registration Date/Time: 2015 01-08 19:58:36 HCaICERTS inc. -CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-01062015-694 Report Generated at: 2015-01-08 15:59:10 Sladden Engine'eri 45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite C, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA92223(951) 845-7743 Fax (951) 845-8863 800 E. Florida Avenue, Hemet, CA 92543 (951) 766-8777 Fax (951) 766-8778 November 19, 2014 Project No. 544-14292 14-11-444 Mr. Joe & Mrs. Beth Giordano 4034 Arhaus Drive Hermitage, Pennsylvania 16148 Project: Proposed Giordano Residence 80-605 Via Montecito The Hideaway La�Quinta, California Subject: Geotechnical Update - Ref: Geotechnical Engineering Report prepared by Earth Systems Southwest (ESSW) dated September 22, 2000; File No. 07117-10, Report No., 00-09-772 Report of Testing and Observation During Rough Grading prepared by ESS dated . August 28,2002; File No. 07117-11, Report No. 01-07-718 Report of Testing and Observation During Rough Grading prepared by Sladden Engineering dated October 12;2003; Project No. 544-2199 Report No. 03-10-647 As requested, we have reviewed the above referenced geotechnical reports as they relate to the design and construction of. the proposed custom residence. The project site is located at 80-605 Via Montecito within the Hideaway Golf Club development in the City of La Quinta, California. It is our understanding that the proposed residence will be a relatively lightweight wood -frame structure supported by conventional shallow spread footings and concrete slabs on grade. The subject lot was previously graded,during the rough grading of the Hideaway project site and Was subsequently regraded. The rough grading included over -excavation of the native surface soil along with the placement of engineered fill -soil to construct the building pads. The regrading included processing the surface soil along with minor cuts and fills to construct the individual building pads to the current configurations. Some additional over -excavation was performed in areas where the building envelopes were - reconfigured. The most . recent site grading is summarized in the referenced Report of Testing and Observations During Rough Grading prepared by Sladden Engineering along with the compaction test results. The referenced reports include recommendations pertaining to the construction of residential structure foundations. Based upon our review of the referenced reports, it is our opinion that the structural values included. in the referenced grading report prepared by Sladden Engineering remain applicable for the design and construction of the proposed residential structure foundations. Sladden Engineering September 19, 2014 -2- Project No. 544-14292 14-11-444 . Because_ the lot has been previously rough graded; the remedial grading required at this time should be minimal provided that the building falls within the previously established building envelope. The building area should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted to a minimum of 90 percent relative. compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. The allowable bearing pressures recommended ' in the referenced grading report prepared by Sladden Engineering remain applicable. Conventional shallow spread footings should be, bottomed into properly compacted fill material a. minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad. footings should be at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf for each additional 1 foot of width and 300 .psf for each additional 6 inches of depth may be .utilized if desired.The maximum allowable bearing pressure should be 3000 psf. The recommended allowable bearing pressures may be increased by one-third for wind and seismic . loading. Lateral forces may resisted by friction along the base of the foundations -and passive resistance along the sides of the footings. A friction coefficient of 0.50 times" the normal dead load forces is recommended for use in design. Passive resistance may be estimated using an equivalent fluid weight of 300 pcf., If used in combination with the passive resistance; the frictional resistance should be reduced by one third to 0.33 times the normal dead load forces. The bearing soil is non -expansive and falls within the "very low" expansion category in accordance with 2013 California Building Code (CBC) classification criteria. Slab thickness and reinforcement should be determined by the structural. engineer. We recommend a minimum floor slab thickness of 4.0 inches. All slab reinforcement should be supported on concrete chairs to ensure that reinforcement is placed at slab mid -height. Slabs with moisture sensitive surfaces should be underlain 'with a, moisture vapor retarder consisting of a polyvinyl .chloride membrane such as 10 -mil ' Visqueen, or equivalent. All laps within the membrane should besealed and at least 2 inches of clean sand should be placed over the membrane to promote uniform curing of the concrete. To reduce the potential for punctures, the membrane should be placed on a pad surface that has been graded smooth without any sharp protrusions. If a smooth surface can not be achieved by grading,'consideration should be given to placing a 1 -inch thick leveling course of sand across the pad surface prior to placement of the membrane. Based on our field observations and understanding of local geologic conditions, the soil profile type judged applicable to this site is SD, generally described as stiff soil. The following presents additional coefficients and factors relevantao seismic mitigation for new construction based,upon the 2013 California Building Code (CBC). September 19, 2014 -3- Project No. 544-14292 14-11-444 The seismic design category for a structure may be determined in accordance with.Section 1613 of the 2013 CBC or ASCE7. According to the 2013 CBC, Site Class D may be used to estimate design seismic loading for the proposed structures. The 2013 CBC Seismic Design Parameters are summarized below.. Risk Category (Table 1.5-1): I/11/11I . Site Class (Table 1613.3.2): D Ss (Figure 1613:3.1): 1.5008 S1 (Figure 1613.3.1): 0.6848 Fa (Table 1613.3.3(1)):1.0 Fv (Table 1613.5.3(2)):1.5 Sms (Equation 16-37 (Fa X Ss}):1.500g ' Sm1 (Equation 16-38 (Fv X S11): 1.026g SDs (Equation 16-39 (2/3 X SMS)): 1.000g SDI (Equation 16-40 (2/3 X Sm1j): 0.6848 Seismic Design Category: D In addition, we have sampled the surface soil on the subject. lot to determine the soluble sulfate content as it relates to selecting appropriate concrete mix designs. Testing indicates that the site soil is generally considered extremely corrosive with respect to concrete. The testing indicated soluble sulfate content of 1800 ppm (0.180 percent) that corresponds with . the "moderate" exposure category in accordance with ACI 318-08, Table 3. In accordance with ACI 318-08, special sulfate resistant concrete mix designs will be required. Structural concrete placed in contact with soil should have a minimum compressive strength of 4000 psi and a maximum water/cement ratio of 0.50. If you have questions regarding this letter or the referenced reports, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERING } pFESJ���� BRETT L. �`ry Brett L. Andeison I io. C4 8s Principal Engineer E:p. 9130116 m - CML SER/ m c3'.' ENGINEERING �' � .yrs 04a\ OF CpQ Copies: 4 / Addressee • .Q%q/i/la 1! �I ➢s /il DsnnMisn Shen Engineering 6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax '(714) 523-1369 45090 Golf Center Pkwy, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 . Date: November 24, 2014- Account 014Account No.: 544-14292 " Customer: Mr. Joe & Mrs. Beth Giodano Location: 80-605 Via Montecito, La Quinta Analytical. Report f Sulfate .Series Soluble Sulfates Soluble Chloride per CA 417 per CA 422 PPM - ppm 1800. 60 Rnlfa4o rAA-iA9a') ii7A1A 'TABLE 19=A-2—REQUIREMENTS FOR SPECIAL EXPOSURE cnl•tnmnM_q TABLE 19-A-3--REQUIREMENTS-FOR CONCRETE FXPnSFn Tn CI It t itTe_rnerrnrinur._r AINIMUM I ", IdAXIMUtd • • OR AL'-WEIGIiT AMD , WATERLtEmEIftmoUS uG.HY. E1GNT. MATERIALS' RATIO BY. ;' :AA.GG.REG ATE -ORCRETt•WEIGHT,'NORIaAL'=WEIGHT;=psl:.EXPOSURE CONDITIon AGGREGATE CONCRETEx o.D=19•lor MPa Con4rcte intended to have low permeability when SULFATE exposed to water 0.50 4,000 Conerele exposed to•freczing and thawing in a moist �lohtwelght' AgoMp°te EXPOSURE condition or to deicing chemicals 0,45 4,500 { For corrosion projection for reinforced concrete .Concrete,;pslt x D.006119'torMP& exposed to chlorides from deicing chemicals, salts or WATER, ppm brackish t4atcr, orspl-ay.from thesc'sources ConeretaI Negligible 0.00-0,10 0.40 5,000 TABLE 19-A-3--REQUIREMENTS-FOR CONCRETE FXPnSFn Tn CI It t itTe_rnerrnrinur._r IiT TE . -- •.us,ru ILt=agul may oc�gmred for tow permeabilityorforprotceiian _Seawater_ against corrosion 'Df embeddtd items or Crecxing and thawing (Zablp 19-A-2). , Seawater- ?Po—lan that has been determined by test or -service record to improve sulfate resistance when usrd inconcrete `con- Laiaiing Type. V cemenL 2-264 NORMAL -WEIGHT UGHTWEIG AGGREGATE CONCRETE Maxlmum'Water- Cemendttoua 1, 'Normal -Wolghtrond WATER SOLUBLE SULFATE SULFATE SO IN 5011 MdterialsaRndo;bp:. W. -I 1t°A �lohtwelght' AgoMp°te EXPOSURE PRGPINTAGE8Y WEIGHT SULFATE(So,)IN °f-Wdgfit ggregate .Concrete,;pslt x D.006119'torMP& WATER, ppm CEAIERTTYPE ConeretaI Negligible 0.00-0,10 0-150 Modctate2, 0-10-0.20. 150-1,500 U,1P(MS),LS '0S0• 4,000 . (MS) Seven 0.20-2.00 1,500-10,000 V 0.45r • ' Very seven Over 200 Over 10,000 Y plus 0.45 ..4,500 4,504 ' poaolan3 r to Inwr•r.,,�p.r1•.,,,. ,*,'.-...—_._-_, IiT TE . -- •.us,ru ILt=agul may oc�gmred for tow permeabilityorforprotceiian _Seawater_ against corrosion 'Df embeddtd items or Crecxing and thawing (Zablp 19-A-2). , Seawater- ?Po—lan that has been determined by test or -service record to improve sulfate resistance when usrd inconcrete `con- Laiaiing Type. V cemenL 2-264 LA Q TJ I N `I~.A P9e8se verify that soils reports contain all of the above information. In addition, to. assure continuity. between-the investigationlreporting stage and the execution stage, please use the following checklist to verify that the conclusions and recommendations in the report cover all the required -elements. Only then, canme be assured that the construction documents address all of the site soil conditions. -La Quinta Geotechnical Report Checklist Does the "Conclusions and Recommendations" section of the report add.re'ss each of the following criteria? 'Address" means: (a) the criterion is considered significant and mitigation measure(s) noted,.Or; (b) the criterion. is considered insignificant and explicitly.so stated. Yes No Criterion r -'---� ,. -!� Found-anon-crifieria-based-u.--- ..._ ....p-orrtrearing-capa�ityof-naturai-or c�sm�a�ted-soii: .. . r . ® Foundation criteria to mitigate the'effects of.expansive soils. 0 Foundation criteria based upon bearing capacity-of natural or--compacted soil. .® Foundation criteria to mitigate the effects of liquefaction. ® Foundation criteria• to mitigate the effects,*0 seismically induced differential settlement, ® Foundation criteria to mitigate the effects of long-term differential settlement. ®. Foundation criteria to mitigate the effects of va mn g...............................ryi . g soil strength. ® Foundation criteria to mitigate expected total and differential settlement. Any "filo'. aansWers to the-above checklist should be noted as specific required corrections.�� # # F4 O�RSON C4m 53a9 C. . •r �lG� RIR lG a`Z 4.`�� OF C��t�