Loading...
07-1666 (SFD)4 P.O. BOX 1504 VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 8/17/07 Application Number: 07-00001666 Owner: Property Address: 80745 VIA MONTECITO KEN & ANDREE NELSON APN: 772-410-999-59 -298944- 3113 FAIR WEATHER Application description: DWELLING - SINGLE FAMILY DETACHED BELLEVUE, WA 98004 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 421198 r�`�"" - Contractor: Applicant: Architect or Engineer: CAL -TECH DEVELOPMENT CORPii� 78150 CALLE TAMPICO STE 205k k1lIG r 2007 st LA QUINTA, CA 92253 _ p (760) 771-3738 cirlOFILA4 UAWTA ! C Lic. No.. 683969 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9. (commencing with Sectio 70001 of Division 3 of the Bu ess and P ofessionals Code, and my License is in full force and effect. Lic Class: B LicenselN/o,.{p:� 683969 ,at Contractor:/"" '� .J OWNE -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicaht for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and , the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or impre•:e far tha p.,,,,w .l (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERA11T WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 1768839 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section Date:I�I 71�0J!QJ1-of the Labor d/e,, �I shall fo with comply with thosee provisions. ' /Applicant: V t, �`�•' WARNING: FAILURE TO SECURE WORKERS' COMPENSATIO COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANI ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all citJan county ordinances and state laws relating to building construction, and hereby authorize representatives ofupon the above-mentioned prop ty for inspec io p poses. Da111 Signature (Applicant or Agentl: Application Number . . . . . 07-00001666 -=---- Structure Information 4,791SF DWELLING V-NR/RES-3/CLASS A -FR ----- Other struct info CODE EDITION 2001/2005 # BEDROOMS 3.00 FIRE SPRINKLERS NO GARAGE SQ FTG 1276.00 PATIO SQ FTG 678.00 NUMBER OF UNITS 1.00 ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 4791.00 Permit . . . . . . BUILDING PERMIT. Additional desc . . Permit Fee . . . . 1766.50 Plan Check Fee 1148.23 Issue Date . . . . Valuation . . . . 421198 Expiration Date 2/13/08 Qty Unit Charge Per Extension BASE FEE 639.50 322.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,001-500,000 1127.00 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . . Permit Fee . . . . 223.21 Plan Check Fee 55.80 Issue Date . . . . Valuation . . . . 0 Expiration Date 2/13/08 Qty Unit Charge Per Extension BASE FEE 15.00 4791.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 167.69 1276.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 25.52 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 2/13/08 QLy uniL charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . 182.50 Plan Check Fee 45.63 LQPERM IT Application Number . . . . . 07-00001666 Permit . . . . . MECHANICAL Issue Date . . . . Valuation . . . . 0 Expiration Date _2/13/08 Qty Unit Charge Per Extension BASE FEE 15.00 '2.00 9.0000 EA MECH FURNACE <=10OK 18.00 3.00 11.0000 EA MECH FURNACE >100K 33.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 3.00 9.0000 EA MECH B/C <=3HP/100K BTU 27.00 2.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 33.00 6.00 6.5000 EA MECH VENT FAN 39.00 2.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD 13.00 Permit PLUMBING Additional desc . Permit Fee 206.25 Plan Check Fee 51.56 Issue Date Valuation . . . . 0 Expiration Date 2/13/08 Qty Unit Charge Per Extension BASE FEE 15.00 22.00 6.0000 EA PLB FIXTURE 132.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00' 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 13.00 .7500 EA PLB GAS PIPE >=5 9.75 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 4,791SF DWELLING/V-NR/RES-3/CLASS A -FR. THIS PERMIT DOES NOT INCLUDE BLOCKWALLS POOL AND SPA OR DRIVEWAY APPROACH. 2001 CBC, CPC, CMC, 2004 CEC, 2005 ENERGY. August 17, 2007 11:09:51 AM AORTEGA ----------------------------------------------------7----------------------- Other Fees . . . . . . . . ART IN PUBLIC PLACES -RES 552.99 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVICC CDNTDR o RE3 993.00 ENERGY REVIEW FEE 114.82 DIF FIRE PROTECTION -RES 140.00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 42.11 DIF STREET MAINT FAC -RES 67.00 0 LQPERMIT Application Number . . . . 07-00001666 ----------------------------------------------------- Other Fees . . . . . . . . . ---------------------- DIF TRANSPORTATION - RES 1930.00 Fee summary ------------------ Charged Paid. Credited Due Permit Fee Total ---------- 2393.46 ---------- .00 -------------------- .00 2393.46 Plan Check Total 1301.22 750.00 .00 551.22 Other Fee Total 5184.92 .00 .00 5184.92 Grand Total 8879.60 750.00 .00 8129.60 LQPEIN1IT P.O. BOX 1504 APPLICATION ONLY Building QCALLE TAMPICO Address a�"„{e „LA QUINTA, CALIFORNIA 92253 , Mailing �11 �a�� Address ,fig Ity t>0\k v U� � zlp�%0 Tyi?G .q w:;, -)U I Contract 11-"(?—CAr\ Address � � — 7 nSA CityQ M�� Z �ZS T I. -11 - _�J_i 13g State Lic. City i & Classif. Lic. # 1 Arch.,n r. n � �LA Designer \�j , A dress TeI,C) LpyCi tv 3 Zij 2211 State II U"q-1 LICENSED CONTRACTOR'S DECLARATION I hereby affirm at I am I'censed under provisions of Chapter 9 (commencing ith Section 7000) of Divisio of the siness and Professions Cod and my license i i f II fore d effect. SIGNATURE DATE OWNER- R DECLARATION I hereby affirm that I am exempt from 'tie Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work hiMself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company O Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall nol employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.' If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY 1 hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CONST. OCC. GRP. A.P. Number —I —1 -1 :U b • 1) 05 Legal Description "'r ► { _ 1 Project Description f\y ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Validated I Validation: YELLOW = APPLICANT Date Permit PINK = FINANCE Sq. Ft. (j Size 'I -I I No. Stories I No. Dw. Units J New)c Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Q Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure z1 r FINANCE EPT TOTAL • REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Validated I Validation: YELLOW = APPLICANT Date Permit PINK = FINANCE w. Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 —.Fax (760) 398-1224 Project Name: This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/END. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS: ' CERTIFICATE OF COMPLIANCE (California Education Code 17620) Date: 8/21/07 Owner's Name: Ken & Andree Nelson Phene No. (760) 771-3738 Project Address: 80-745 Montecito, Hideaway, La Quinta, CA 92253 Project Description: 1 Single Family Dwelling APN: 777 400 005 t #: Lot #'s: Type of Development- Residential XX Commercial Industrial Total -Square Feet of Building Area: 4791 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: 8/21/07 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code 65995 4791 $3.48 $16,672.68 Building Permit Application Completed: Yes/No Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement Note: By: Carey M. Carlson, Asst. Supt., Support Services Certificate issued by: Marcela Valdez Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written no ce to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in- section 66020 of the Government code. Additionally, the amount of the fees imposed .s as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not Been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. MV:c/mydocs/devfees/certificate of compliance form tablesTO USE.doc 1/16/03 T _=-• - B.G. STRUCTURAL ENGINEERING BRIAN GOTTLIEB - CIVIL ENGINEER - Lic. No. C33047 43-100 Cook Street, Suite 203 Palm Desert, CA 92211 (760) 568-3553 (760) 568-5681 Fax January 17, 2008 Mr. Jeff Lohman Cal Tech Development Corp. 78-150 Calle Tampico, Suite 205A La Quinta, CA 92253 RE: Nelson Residence — 80-745 Via Montecito, La Quinta, CA The purpose of the site observation work undertaken by B.G Structural Engineering for the above named project was to confirm that this proje:t has been constructed in general conformance with the structural drawings and as required by the 2007 CBC Section 1702. Observation of the construction of this project was conducted or supervised by Brian Gottlieb of this office. These observations were to es=ablish the conformance of several items including, but not limited to: conformance of framing to framing plans, the assembly of shear walls, wall sheathing, drag straps, holdowns, and detailed connections. Corrections were provided after each observation to communicate the items of concern to the builder. Sutsequent re- checks of the structure for compliance were performed until all outstanding correction items were resolved. In conclusion it is the opinion of this office that the construction of this project is in general conformance with the requirements of the structural drawings. The conclusions reached above are based solely on a visual review of the structure. Due to the visual nature of these observations, and limited access to structural elements, a general review of the structural elements and connections has been performed. No tests have been conducted on any materials or soils and no warranties are expressed or implied. The opinion above is based -upon widely held engineering principles and judgment, and it follows a standard o" care which defines a level of skill and competence ordinarily and contemporaneously demonstrated by professionals of the same discipline practicing in the same locale and faced with the same or similar facts and circumstances. • Nelson Residence, La Quinta, CA. Page 2 of 2 January 17, 2008 Please call me at (760) 568-3553 if you have any questions or would like to discuss this matter. Sincerely, Brian Gottlieb, P.E. cc: file Page 2 VALID ONLY IF SIGNED IN RED Certificate of Occupancy. �a a�� Ot V.- INcaironn�svG4 C� OBuildin & Safet Department F 9► Y p This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 80-745 VIA MONTECITO Use classification: SINGLE FAMILY DWELLING Building Permit No.: 07-1666 Occupancy Group: R-3 Type of Construction: V -N Land Use Zone: RL Owner of Building: KEN & ANDREE NELSON Address: 3113 FAIR WEATHER City, ST, ZIP: BELLEVUE, WA 98004 By: STEVE TRAXEL Date: SEPTEMBER 11, 2008 Building Official POST IN A CONSPICUOUS PLACE JCM Inspections RA 39725 Garand Lane Suite F ah Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS EPDXY INSPECTION. REPORT Date:. Project Name: Project No: 07-1205 Nelson Residence @ The Hideaway e c t ddr s: City: 80-745 Via Montecito LE. Quinta, CA e Sub -Contractor: Owner R & D Concrete General Contractor: Architect: Structural =ngineer: Cal Tech Development B. G. Structural Engineering, Inc. dAnchor Bolts Rebar Epoxy Types'�cF Si? ��' �-1 C\(Z' , — - Epoxy Shelf Life: kAeg Hole Cleaning Methods);\oar �QO(1.r ❑✓ IBC Title 24 Other: Unresolved Items: None See Below Description of Work Inspected: to�® ycX f1V_)CnaC- '6Ca��^ W� 0\3f� F10,r \A t r� \®ibh_lo_10 olz_ gra ��,o v�I n o� t M,-, % Q exk 00 K1 � �� o c'���5 � � o no- C �?�ac ��10-ter a -°-0V p � r G , \ C\ Oso o� \i 1>4& I 2 jOy ✓ h 4� V� 1 a)tn A )1i?,Z C_11 \00 : 'SNS peg .a S,va. Cv C j1 �� Q\' 11 %-nck^ 0 r \)C>A & 0l Inc\ r 1 .y �S V Al P v r1C .'tomr Work complies with written approval from Structural Engineer and ICC Evaluation Report # 1 1 hereby'oertify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications -applicable building laws. Final report issued at project completion. Inspector: Jack C._Millin ICC C Ii\fi"baBon N,o: 0842216-49 Contractor's Representative: Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page of Y I TITLE 24 REPORT I Title 24 Report for: The Nelson Residence Lot 59-D La Quinta, CA 92253 Project Designer: Demetriou Architects 5555 Lakeview Drive Suite 200 Kirkland, WA 98033 (425) 827-1700 Report Prepared By: CJ McFadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA 8 Job Number: Date: 7/23/2007 T 9 � 0 T T H JUL 2 7 2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: User Number: 3665 I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 9 Form WS -5R Residential Kitchen Lighting 11 HVAC System Heating and Cooling Loads Summary 12 Room Load Summary 16 Room Heating Peak Loads 20 Room Cooling Peak Loads 24 EnergyPro 4.3 by EnergySoft Job Number: User Number: 3665 I 4 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R _T_he_Rels.o.n_Re.si.d.e.n.ce 1.,098 7_/_23/2007 Project Title _HYAG#3 Date _Lot_5.9-D La_Q.uinta 4.35 OPAQUE SURFACES Project Address Azm. I Buildirg Permit# B.REEZEA_ I.R_C01V.D1_T_I.ON.I.NG Wood_ (760) 346-0855;plan Documentation Author _SbepingStat_ Cieck/Date Telephone I _En.er__g_y_P_r_o .W_ .00d_ CA C-flMate_Z.one-1_5 ' Field Check/Date Compliance Method 0.9.0 Climate Zone TDV Standard Proposed Compliance (kBtu/sf-y) Design Design Margin Space Heating 2.67 4.63 -1.97 Space Cooling 64.47 54.59 9.88 Fans 9.19 7.78 1.41 Domestic Hot Water 5.36 6.00 -0.64 Pumps 0.00 0.00 0.00 Totals 81.68 73.00 8.68 Percent better than Standard: .09A6 10.6% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: ;XJ Single Family C Addition Total Conditioned Floor Area 4,791 ft2 Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (N) 0 deg Fuel Type: Natural Gas Fenestration: Area: 835 ft 2 Avg. U: 0.39 Ratio: 17.4% Avg. SHGC: 0.35 BUILDING ZONE INFORMATION Zone Name Floor Area Volume .HVAC=#J 1.,098 _H_YAG42 4.69 _HYAG#3 2..Z89 .HVAG_#4 4.35 OPAQUE SURFACES I I t' A t 1.2,07.8 _5.,15.9 41.835 4,.7.8.5 Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units Number of Stories: # of 0 ft2 Units nsu a lon %1. Sleeping Type Frame • Area U -Fac. Cay. Cont. Azm. Tilt Roof Wood_ 1,096-0-025- _EZ38_ _[Z0.0_-34.5_ _SbepingStat_ 0 _W_ all_ .W_ .00d_ 3.6.8. _0..0.69_ _R=21. _R=0..0_ 0.9.0 ZD.NE#2 Wall_ Wood_ 39.6_ _0...0.69 _R21. _R=0...0_ -9.0.9.0 ZDN E_#2 Wall_ Wood- -29.9. _0_069_ _R2.1. _RU -0_ 1.80_ 90 -Wall- Wood_ 41.2. _0..0.69 _R21__? 0..0_ 2709.0 ZINE - Roof -Wood- _0.9_A6 46.8_ _0..025_ -R=3.8_ _R=0..0_ -3.4.5_ 0. -Wall-Wood- .09A6 _ 173_ _0..069_ -R21. -RU-0- 0__9.0 =NE#4 Wall_ Wood_ 27.5. _0._0.69_ -R21 _R=0..0_ -9.0.9.0 ZON E_#_4 Wall_.W_.00d_20_4__0..0.69__R21_R=0-0_ 1.8.0_ 9.0 Wall_ Wood_ 26.9_ _0..0.69_ -R21. _R=0_.0_ _2.7.09.0 Root- Wood_ _2,7.89. _0_025_ _R 38_ _R=0_.0_ _34.5_ 0 Wall_ Wood- 6.02. _0_069_ -R21 J?L0_.0_ -0--9.0 Wall_ Wood_ 6.64 -0..0.6.9. _R21. _B0,0- -9.090 Wall- Wood_ 6.5.3_ _0...0.69_ _R=21. _R=0..0_ 1.8.0 9.0 Wall_ Wood_ 7.28_ _0...0.69 _B=21. _R=0_0_ -2.7.0_9.0 Roof Wood_ 4.3.4_ _0...025_ -R=3.8_ _R_0..0_ _34.5_ 0 Wall_ Wood_ _29.4_ _0_069_ _R=21. _R=O._0_ -0--90 Wall_ Wood- 1.81 _0..069_ -R21. _R=0.0_ _9.0_-9.0 Wall- Wood_ 336. _0.069_ -R=21. _EZO_0_ 180_ 90 -Wall- Wood- 19.8_ _09.6.9_ _IR21. _R=0..0_ -2.7.0.9.0 Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units Number of Stories: # of 0 ft2 Units Zone Type _0.23_ Sleeping _0..10_ -Sleeping- leeping-0..58_ -0-58- Living _0...0.9_ -Sleeping- Gains Condition Y / N Status JA IV Reference Location / Comments !New 0 ft2 ZDNE.#_1 4,791 ft2 _0.9=A6 13.3 ft ]New 1.00 ZINE_#_1 1 TI-ermostat Vent Type Hgt. Area _SleepingStat_ ? -n/a _SbepingStat_ 2 _n/a -Living-Stat 2 _n/a _S_eepingS.tat_ 2 _o/a Gains Condition Y / N Status JA IV Reference Location / Comments !New _01_A1.8 ZDNE.#_1 ]New _0.9=A6 ZDNE_#1 ]New _0.9=A6 ZINE_#_1 ]New _09A6 Z•D.NEE#1 ]New _0.9=A6 Z°DNE_#_1 ]New _01=A1.8 Z.DNE#2 ]New _09A6 Z.D..NE_#2 ]New _0.9A6 ZD.NE#2 INew _0.9_A6 Z.7NE_#2 I New _0.9=A6 ZDN E_#2 '.New _O1A18 ZD.NEA3 ]New _09A6 ZD..NE_#3 !New _0.9=A6 ZDNE_#3 ]New _0.9_A6 ZINE - #3 -New _0.9_A6 ZINE - #3 -New _01Ja18 Z.NE_#4 ]New .09A6 ZZME_#4 ]New _09A6 =NE#4 lNew _09A6 ZD.NE#9 I New .0.9=A6 ZON E_#_4 Run Initiation Time: 07/23/07 13:22:43 Run Code: 1185214963 EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page:3 of 28 Certificate Of Compliance : Residential (Pa -t 2 of 4) CF -1 R The Nelson Residence 7/23/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor SHGCZ Azm. Tilt Stat. Glazinq Type Comments _L _Skylight_F_ront_(N)_ 1A _0..8.4-0 11.6_A-_0,67 116=B _3_45_ -0- New -Skylight # _ZONE#_1 2 Skylight Front (N)_ 1.1 0.840 116-A 0_67 116-B 345 0 New Skylight ZONE #1 3 Window Rear (S)_ 72.0 0.330 NFRC 0_28 NFRC 180 90 New Loewen HP1(SwngGlsDr_(105)_ ZONE #1 4 Window Rear (S)_ 4.0 0.300 NFRC 0_28 NFRC 180 90 New Loewen HP1 Csmt _(106a) ZONE #1 5 Window Rear (S)_ 15.8 0.290 NFRC 0.33 NFRC 180 90 New Loewen HP1 (Fxd)_(106b) ZONE #1 6 Window Right (W)_ 6.0 0.300 NFRC 0;28 NFRC 270 90 New Loewen HP1 (Csmt)_(106c) ZONE #1 7 Window Right (V1n_ 6.0 0 300 NERC 0.28 NFRC 270 90 New Loewen HP1 (Csmt)_(1 7 ZONE #1 8 Skylight Front (Y) 1.1 0.840 116-A 0.67 116-B 345 0 New Skylight ZONE #2 9 Window Front (N)_ _ 36.0 0 30O NFRC _Q.28 NFRC 0 90 New Loewen HP1 (Csmt)_(103) ZONE #2 10- 0.76 -Window-Right--(W-)- 6.0 -0-300 NFRC 0.28 NFRC _270_ 90_ New Loewen HP1 (Csmt)_(104) ZONE #2 " Window Front (N)_ 12.0 0.300 NFRC 0.28 NFRC 0 90 New Loewen HP1 (Csmt)_(121) ZONE#3 12 Window Front (N)_ _ 48.0 _0.290 NFRC 0.33 NFRC 0 90 New Loewen HP1 (FxOd _ 1( 10a) ZONE #3 13. wndow_F_ro.nt_(N)_ 0.1 2.0 -6-3 _0--.290 NFRC 0:33 -NERC 0_ _90. N.ew Loe-wen_HE1_(Exd.)_(1_1.Ob) _ZONE_#_3 14 Window Front (N)_ 6.3 0.290 NFRC 0_33 NFRC 0 90 New _Loewen HP1 (Eg (11Oc) ZONE #3 15 Window Front (N) 60.0 0.770 116-A 0_59 116-B 0 90. New Default Dbl Mtl Tint(SwnpG sQr ZONE #3 16 Window Front (N) 6.3 _0.300 NFRC 0_28 NFRC 0 90 New _ LiA'Wen HPI (Csmt _(102j ZONE #3 17 Window Front (tom 24.0 0.320 NFRC 0_19 -NERC 0 90 New Loewen HP1 (SwngG Dr rl 13c)_ ZONE #3 18 Window Left (_ 16.0 0.290 NFRC 0_33 NFRC 90 90 New Loewen HP1 (Fxd)_1( 14b) ZONE #3 19 Wndow_Left_(E)_ 48 0 0.770 116-A 0-59 -i -16:B 90_ 90 New wnngsDr)_O D/efault_Dbl MtL Tint(SG ZNE #3 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11a2) / INTERIOR AND EXTERIOR SHADING Window Insulation Overhang Left Fii Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 ZONE #1 Slab Perimeter 88 None No Insulation _ 26-A1 New 2 None 1.00 None No Insulation 26-A1 New ZONE #3 Slab Perimeter 101 3 Bug Screen 0.76 8.0 9.0 6.0 0.1 6.0 6.0 4 Bu -q Screen 0.76 2.0 2.0 --1-Q-0 01 10.0 --100 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 None 1.00 9 Bug Screen 0.76 _ 10 Bug Screen 0.76 11 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 6.0 8.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 2.6 2.6 2.0 0.1 2.0 _ 2.0 14 Bug Screen 0.76 2.6 2.6 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 10.0 6.0 10.0 0.1 10.0 _ 10.0 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 4.0 4.0 10.0 0.1 _ 10.0 10.0 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 144 None No Insulation 26-A1 New ZONE #1 Slab Perimeter 88 None No Insulation _ 26-A1 New ZONE #2 Slab Perimeter 345 None No Insulation 26-A1 New ZONE #3 Slab Perimeter 101 None No Insulation 26-A1 New ZONE #4 4.3 by EnergySoft User Number: 3665 Job Number: PaaeA of 28 Certificate Of Compliance : Residential (Pat 2 of 4) CF -1 R The Nelson Residence Project Title 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Date 7/23/2007 FENESTRATION SURFACES # Type Area U -Factor' SHGCZ True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments 20. Wodow Rear(S)_ 21 Window Rear (S_ -3.5.8. 35.8 _0.29.01VF_RC._0_3.3 -NERC 1-8.0_ 0.290 NFRC 0_33 NFRC 180 _9.0_ NewLo.ewen_HP_1_(F-xd)_(]13a) 90 New Loewen HPI (Fxd) (113b) _ZONE#3 ZONE #3 22 Window Rear (S_ 30.0 0.330 NFRC 0_28 NFRC 180 90 New Loewen HP1 (SwngGlsDr)_ 114a _ ZONE #3 23 Window Rear 200.0 0.360 NFRC 0_33 NFRC 180 90 New Weiland StandardS( GD) (1_2)_ ZONE #3 24 Window Right (VMV_ 16.5 0.300 NFRC 0_28 NFRC 270 90 New Loewen HP1 Csmt (122a) ZONE#3 25 Window Right (W)_ 16.5 0.300 NFRC0_28 NFRC 270 90 New Loewen HP1 (Csmt)-(!Ub) ZONE#3 2l Window 27 Skylight Riaht (W)_ Front (N� 90_0 1.1 0.360 NFRC 0_33 NFRC 0.840 116-A 0.67 116-8 270 345 90 New 0 New Weiland $tandard (SGD�_(1 3)_ dight ZONE #3 ZONE #4 28 WindowRear (�_ 33 0 0 300 NFRC 0_28 NFRC 180 90 New Loewen HP1 (Csmt)_(1 IQ) ZONE #4 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 10.0 3.0 10.0 0.1 10.0 10.0 23 Bug Screen 0.76 10_0 20.0 10.0 --k-1 10 0 10_0 24 Buq Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 10.0 9.0 10.0 0.1 10.0 10.0 27 None 1.00 28 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation R -Val. Location JA IV Reference Condition Location/ Status Comments EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page:5 of 28 1 l " t, Certificate Of Compliance : Residential (Pal 3 of 4) CF -1 R The Nelson Residence Kirkland, WA 98033 7/23/2007 Project Title Title/Firm: Address: Date Telephone: HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC -#1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC42 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC43 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Ccndition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC -#1 Ducted Ducted Attic 4.2 New No HVAC42 Ducted Ducted Attic 4.2 New No HVAC43 Ducted Ducted Attic 4.2 New No Hydronic Piping Pipe Pipe Insul.. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank =nergy Tank Insul. Water Heater # in Input Cap. Condition =actor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status Dr RE Loss (%) Ext. Standard Gas 75 gal. Small Gas No Pipe Insulation 1 50,000 75 New 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length U Adti 1/2" Control # HP Type In Plenum Outside Buried InEulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 ofthe California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with =7verall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Demetriou Architects Address: 5555 Lakeview Drive Suite 200 Kirkland, WA 98033 T lephone: (sig t re Enforcement Agency Name: (da ) Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: CJ McFadden Title/Firm: BREEZE AIR CONDITICNI :IG Address: 75-145 ST. CHARLES PLA -,-E PALM DESERT, CA 92211 Telephone:760 346-0855 ,J - (signature) d (date) L EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Pa°e:6 of 28 1 Certificate Of Compliance: Residential (Pat 3 of 4) CF -1 R The Nelson Residence 7/23/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC -#4 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Location Heating Cooling Location HVAC -#4 Ducted Ducted Attic Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Ccndition Ducts R -Value Status Tested? 4.2 New No WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition =actor Standby R -Value System Name Type Distribution Syst. Btu/hr) (gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Control # HP REMARKS Hot Water Piping Length U— Acid 1/2" In Plenum Outside Buried InEulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of1he California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, nsulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name Title/Firm: Demetriou Architects Address: 5555 Lakeview Drive Suite 200 Kirkland, WA 98033 Telephone: _ 425 827-1700 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: CJ McFadden Title/Firm: BREEZE AIR CONDITICNI14G Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (7_60) 334416-0855 (signature) C:7 Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R The Nelson Residence 7/23/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building ordesign that otherwise complies )asea on the aaequacy of the special fustmcation ana aocumentation suomrttea. Plan I Field The Roof "R-38 Roof' includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. The HVAC System "HVAC -#1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -#2" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -#3" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -#4" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a Plan I Field 1" incorporates a Valve nt Charae test or a Thermostatic Expansion The HVAC System "HVAC -#2" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HVAC -#3" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HVAC -#4" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page:8 of 28 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach -used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ Ex] El *§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ 0 ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑ ❑ *§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ Ex] El b. outside air intake with damper and control, flue damper and control ❑ ff J1 ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ perrneance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El ❑ 11CF-6R Form: ❑ ❑X ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfillration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System'Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑X ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page:9 of 28 Mandatory Measures Summary: Residential (Page ? of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance soecifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed orcheck N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (,-ontinued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 6M, 604, ❑ X❑ ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other dud -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ X❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ X❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ X❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operrting ❑ Q ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ X❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ n ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ X❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy lun inaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ n ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility roons shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section f19(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ X❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ X❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 1-9(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 14E. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or mope ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page:10 of 28 1. s Residential Kitchen Lighting Worksheet WS -5R The Nelson Residence 7/23/2007 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that we high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens - Luminaire Type High Efficacy? Watts Quantity High Efficacy Watts Other Watts (1) 2 ft Fluorescent T8 Elec Yes X No n 22.0 x 4 = 88 or (1) 26w Compact Fluorescent Triple 4 Pin Yes X1 No I 1 37.0 x 14 = 518 or U 4 ft Fluorescent T8 Elec Yes I No IXI 32.0 x 1 = or 32 50w Low Voltage Halogen Yes I No1X1-55.0 x 3 = or 165 60w Surface Mount Incandescent Yes I No X 60.0 x 4 = or 240 Yes No x = or Yes No H�..No.. x = or Yes No x = or Yes x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 606 B: 437 COMPLIES IF A >_ B YES- NO ❑ EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number. Paoe:11 of 28 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY (PROJECT NAME DATE The Nelson Residence 7/23/2007 SYSTEM NAME FLOOR AREA HVAC -#1 1,098 PiEATING SYSTEM PSYCHROMETRICS (Airst 26.0 of 75.80F Outside Air 82 cfm 78.5 of SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAKC OIL HTG. PEAK CFM Sensible Latent CFM I Sensible 644 12,8961 2,882 F 665 20,043 0 2,005 2,572 0 0 82 3,313 1,934 82f 4,600 0 2,572 2,005 20,220, 4,817 29,787 PSA2BD / PGC1 RA (4 Ton) 13 SEER 1 39,367 0 58,000 Total Adjusted System Output 39,367 0 58,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm r Jan 12 am 109.9 of Heating Coil 109.9 of O Supply Air.Ducts Supply Fan 108.3 of 1600 cfm I ROOMS 80.0 of Return Air Ducts ` TOOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peale 11.0 / 77.6 of 75.1 / 61.0 of 52.0 / 50.9 of 52.0 / 50.9 of .01"O Supply Air Ducts Outside Air 82 cfm Cooling Coil Supply Fan 53.2 / 51.4 of 1600 cfm 47.8% R.H. ROOMS 73.2 / 59.8 of 72.0 / 59.4 of Return Air Ducts I EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page: 12 of 28 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME The Nelson Residence DATE 7/23/2007 SYSTEM NAME HVAC -#2 FLOOR AREA 469 ENGINEERING CHECKS SYSTEM LOAD ! !Number of Systems 1, COIL COOLING PEAK ;COIL HTG. PEAK. CFM I Sensiblel Latent iI CFM I Sensible] Total Room Loads 370 7,534 1,689 271! 10,600' Return Vented Lighting o Return Air Ducts 1,171 1,3601 Return Fan 0 01 Ventilation 35 1,408 841 351 1,962 Supply Fan 1 01 0. Supply Air Ducts 1,171 1,360 TOTAL SYSTEM LOAD 1 11,2841 2,530, 15,282 ' ,Heating System Output per System 36,000 Total Output(Btuh) 36,000 Output (Btuh/sqft) 76.8 Cooling System Output per System 24,000 1 Total Output (Btuh) 24,000 Total Output (Tons) I 2.0 Total Output(Btuh/sqft) 51.2 Total Output (sgft/Ton) 234.5 Air System HVAC EQUIPMENT SELECTION CFM per System 800 PSA2BD / PGC1 RA (2 Ton) 13 SEER 20,032 0 36,000 Total Adjusted System Output 20,032 0 36,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Airflow (cfm) 800 Airflow (cfm/sgft) 1.71' Airflow (cfm/Ton) i 400.0 Outside Air (%) I 4.4 1 Outside Air (cfm/sqft) 0.07 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 76.10F 118.40F 118.4 OF O Supply Air Ducts Outside Air '35 cfm Heating Coil Supply Fan 116.80F 800 cfm ROOMS 78.4 of 80.0 of Return Air Ducts ` I. DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Pea 111.0 / 77.6 of 75.0/60.80F 51.5 / 50.4 of 51.5 / 50.4 OF Outside Air 0 :•upply Air Ducts 35 cfm Cooling Coil Supply Fan 52.9 / 51.0 of 800 cfm 47,3% R.H. ROOMS 73.4 / 59.8 of 72.0 / 59.3 OF Return Air Ducts ` I EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page:13 of 28 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME � DATE The Nelson Residence 7/23/2007 (SYSTEM NAME FLOOR AREA I HVAC -#3 2,789 ENGINEERING CHECKS 11SYSTEM LOAD ,Number of Systems 2 COIL COOLING PEAK CFM Sensible Latent Total Room Loads 1,9401 37,5311 6,0901 Return Vented Lighting I 0 Return Air Ducts 5,835 Return Fan o Ventilation 2091 8,372 8431 Supply Fan o Supply Air Ducts 5,835 TOTAL SYSTEM LOAD 57,574, 10,9321, COIL HTG. PEAK CFM I Sensible 1,519 55,487 7,119 0 L 209 11,649 7,119, 81,374 Heating System Output per System 86,000 Total Output (Btuh) I 172,000 Output (Btuh/sqft) 61.7 Cooling System Output per System 58,000 Total Output (Btuh) 116,000 Total Output (Tons) 9.71 Total Output(Btuh/sgft) 41.6 Total Output (sgft/Ton) 288.5 Air System HVAC EQUIPMENT SELECTION PSA2BD / PGC1RA (5 Ton) 13 SEER97,443 0 172,000 CFM per System 2,000 Airflow (cfm) 4,000 Total Adjusted System Output 97,4431 0 172,000 Airflow (cfm/sgft) I 1.43 Airflow (cfm/Ton) 413.8 Outside Air (%) 5.2 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Akug 2 F Jan 12 am Outside Air (cfm/sgft) 0.08 Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 75.60F 116.0 OF 116.0017 SJpply Air Ducts O Outside Air 209 cfm 114.3 of Heating Coil Supply Fan 4000 cfm ROOMS 80.0 OF 78.3 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak:i 111.0/77.6°F 75.3/61.2OF 52.4/51.3OF 52.4/51.3OF O Supply Air Ducts Outside Air 209 cfm Cooling Coil Supply Fan 53.8 / 51.9 OF 4000 cfm ROOMS 48.2% R.H. °F 72.0 / 59.5 of 73.4/60.0 Return Air Ducts I EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page: 14 of 28 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Nelson Residence 7/23/2007 SYSTEM NAME FLOOR AREA HVAC -#4 435 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING FEAK COIL HTG. PEAK CFM ISensiblel Latent 1, CFM Sensible 350 7,196 1,625 2841. 11,120 26.0 OF 76.20F 0 1,119 0 118.5 OF 1,427 0 33 1,308 9 1,119 788 331 1,817 1 0 1,427 10,741 2,413 15,790 HVAC EQUIPMENT SELECTION PSA2BD / PGCIRA (2 Ton) 13 SEER 19,981 0 36,000 Total Adjusted System Output 19981 0 36,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm 7 Jan 12 am HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak), � 26.0 OF 76.20F 118.50F 118.5 OF O Supply Air Ducts Outside Air 33 cfm 116.8 of Heating Coil Supply Fan 800 cfm ROOMS 80.0 of 78.3 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Pealo 111.0/77.6OF 74.9/60.6OF 51.4/50.3OF 51.4/50.3OF O Supply Air Ducts Outside Air 33 cfm Cooling Coil Supply Fan 52.7 / 50.8 of 800 cfm ROOMS 47.0% R.H. of 72.0 / 59.2 of 73.3/59.7 Return Air Ducts I EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page:15 of 28 ROOM LOAD SUMMARY PROJECT NAME The Nelson Residence DATE 7/23/2007 SYSTEM NAME HVAC -#1 FLOOR AREA _1,098 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE I LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE#1 Master Suite 1 644 12,896 2,882 644 12,896 2,882 665 20,043 PAGE TOTAL 1 644 12,896 1 2,882 665 20,043 TOTAL 1 644 12,8SI 2,882 665 20,043 EnergyPro By EnergySoft User Number: User Job Number: Page: 16 of 28 A • ' ROOM LOAD SUMMARY PROJECT NAME The Nelson Residence DATE 7/23/2007 SYSTEM NAME HVAC -#2 FLOOR AREA 469 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME I ROOM NAME Mult. I CFM SENSIBLE I LATENT CFM SENSIBLE LATENT CFM I SENSIBLE ZONE#2 Bedroom #2 1 1 370 7,534 1,689 370 7,534 1,689 271 10,600 F7 I PAGE TOTAL 1 370 7,533 1,686 271 10,600 TOTAL 1 370 7,533 1,689 271 10,600 EnergyPro By EnergySoft User Number: User Job Number: Page: 17 of 28 1 • l ROOM LOAD SUMMARY PROJECT NAME - DATE The Nelson Residence 7/23/2007 SYSTEM NAME FLOOR AREA HVAC -#3 2,789 I ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME I ROOM NAME � Mult.I CFM SENSIBLE LATENT I CFM (SENSIBLE FLATENT CFM I SENSIBLE ZONE #3 Great Room/Dining I I 1' 1,940 37,531, 6,090 1,940 37,53" 6,090 1,519, 55,487 � I i I i f I I ' I i i I i I I 41 1 PAGE TOTAL 1 1,940 37,5:1 6,090 1,519 55,487 TOTAL 1 1,940 37,5:1 6,090 1,519 55,487 EnergyPro By EnergySoft User Number: User Job Number: Page: 18 of 28 ROOM LOAD SUMMARY PROJECT NAME The Nelson Residence DATE 7/23/2007 SYSTEM NAME HVAC -#4 FLOOR AREA 435 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME IMult. CFM SENSIBLE LATENT CFM SENSIBLE. LATENT CFM I SENSIBLE ZONE#4 Bedroom #3 1 350 7,196 1,625 350 7,196 1,625 284 11,120 PAGE TOTAL 1 350 7,196 1,625 284 11,120 TOTAL 1 350 7,1Ri 1,625 284 11,120 EnergyPro By EnergySoft User Number: User Job Number: Page: 19 of 28 1. a ., ROOM HEATING PEAK LOADS Project Title Date The Nelson Residence 17/23/2007 Room Information Design Conditions Room Name Master Suite Time of Peak Jan 12 am Floor Area 1,098 Outdoor Dry Bulb Temperature 260E Indoor Dry Bulb Temperature 80OF Conduction Area U -Value OT of Btu/hr 1 Wall 1095.8 X X X X X X X X X X x x X X x x x X X X X X x x X X X X x x X x x X x x X x X 0.0250 X X X x X x x x X x X x X X X x x x X X X X x X X X X X X x X x X x x X x X X 541 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 1,479 1.1 0.8400 54 50 1.1 0.8400 54 50 368.5 0.0690 54 1,373 396.0 0.0690 54 1,475 298.7 0.0690 54 1,113 72.0 0.3300 54 1,283 4.0 0.3000 54 65 15&- 0.2900 54 247 411.5 0.0690 54 1,533 6.0 0.3000 54 54 97 6.0 0.3000 97 perimeter = 143.5 0.7300 54 5,657 I Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 14,520 Infiltration: [ 1 .001 X 1.064 x 1 098 X 11.00 x 0.477 / 6] X 54 = 5,523 Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 20,043 EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page: 20 of 28 ROOM HEATING PEAK LOADS Project Title Date The Nelson Residence 7/23/2007 Room Information Design Conditions Room Name Bedroom #2 Time of Peak Jan 12 am Floor Area 469 Outdoor Dry Bulb Temperature 260E Indoor Dry Bulb Temperature 80°F Conduction Area LI -Value AT of Btu/hr R-38 Roof 467.9 x 0.0250 x 54 = 632 Skylight 1.1 X 0.8400 X 54 = 50 R_21—Wall 173.0 x 0.0690 x 54 = 645 Loewen HP1 (Csmt_(103) 36.0 x 0.3000 x 54 = 583 .R-2J—Wall 275.0 x 0.0690 x 54 = 1,025 R-21 Wall 203.5 x 0.0690 X 54 = 758 R-21 Wall 269.0 X 0.0690 x 54 = 1,002 Loewen HP1 (Csmt) (104) 6.0 X 0.3000 x 54 = 97 .Slab=On_Grade p nmeter_$7.5 x 0.7300 x 54 = 3,449 x x = x x = x x = x x = x x = x x = x x = x x - x x = x x = x x = x x = x x = x x = x x = x x = x x = x x =. x x = x x = x x = x x = x x = x x = x x = x x = x x = x x = x x - x x = Items shown with an asterisk (•) denote conduction through an interior surface to another room. Page Total: 8,241 Infiltration: L 1.00 X 1.064 X 469 x 11.00 X 0.477 / 6] X 54 = 2 359 Schedule Air Sensible Area Ceiling Height ACH ZIT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 10,600 EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page: 21 of 28 ROOM HEATING PEAK LOADS uate 7/2 Room Name Great Room/Dining Time of Peak Jan 12 am Floor Area 2,789, Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 80°F Conduction Area U -Value Z�T of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 41,4581 Infiltration: [ 1.00 x 1.064 X 2 789 x 15.00 x 0.350 / 6 ] x 54 = 14.029 Schedule Air Sensible Area Ceiling Height ACH dT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 55,487 EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page: 22 of 28 2789.0 x X x X x x X X x X X X x x X x X X X x X0 X X x X x x x x x x X x X x X x X x 0.0250 x X X x x x X X X x X-5-4-= x X x X5-4 x X X X X X x X x X x X x x X X x x x x X x x x 54 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 3.765 6022 0.0690 54 2,244 12.0 0.3000 54 194 48.0 0.2900 54 752 6.3 1 0.2900 54 99 6.3 0.2900 54 99 60.0 0.7700 54 2,495 6.3 0.3000 54 102 24.0 0.3200 54 415 663.8 0.0690 54 2 473 16.0 0.2900 54 251; 48.0 0.7700 1,996 652.9 0.0690 54 2,433 35.8 0.2900 5.4 561 35_8 0.2900 54 5.61 30.0 0.3300 535 200..0_ 0.3600 0.0690 5_4 54 3,8887 2,714 728.3 16.5 0.3000 54 267 16.5 0.3000 54 267 90 0 3600 0.7300 5_4 54 1,.7.5.01 13,60Q perimeter = 345.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 41,4581 Infiltration: [ 1.00 x 1.064 X 2 789 x 15.00 x 0.350 / 6 ] x 54 = 14.029 Schedule Air Sensible Area Ceiling Height ACH dT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 55,487 EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page: 22 of 28 A . • . ROOM HEATING PEAK LOADS Project Title Date The Nelson Residence 17/23/2007 Room Information Design Conditions Room Name Bedroom #3 Time of Peak .tan 12 am Floor Area 435 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 80°F Conduction Area U -Value AT of Btu/hr R-21 Wall 433.9 X X X X x X X x x X x x X X X X X X X X X x x x x x x x X x X X X x x X X X X 0.0250 x X x x X X x x x X x X X x x X X x X x X X X x x x X X x x X X x X x X x X X 54 = = = = = = = = _ = = = = = = = = = = = = = = = = = = = = = 586 1.1 0.8400 54 50 294.0 0.0690 54 187.0 0.0690 54 335.5 0.0690 54 g697 33.0 0.3000 54 198.0 0.0690 54 738 perimeter =101.0 0.7300 54 3 981 I Items shown with an asterisk (7 denote conduction through an interior surface to another room. Page Total: 8 932 Infiltration: F 1.00 X 1.064 X 435 x 11.00 x 0.477 / 60] x 54 =2,188 Schedule Air Sensible Area Ceiling Height ACH oT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 11,120 EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page: 23 of 28 RESIDENTIAL ROOM COOLING LOAD SUMMARY 1Project Title (Date i iThe Nelson Residence 17/23/2007 :Room Name: Master Suite i Outdoor Dry Bulb Temperature:. 112"F ' Floor Area: 1,098 sf Outdoor Web Bulb Temperature: 78OF iIndoor Dry Bulb Temperature: 72OFiOutdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 1. Cooling Load Temperature Difference (CLTD) Fenestration Cs Orientation (� N (E (SS 1 1,095.8 X X X X X x x x x x xx(� x 0.01731 X X X X X x X x x x xL�= 56.0 = = = = = = = = - = 1= 368.5 0.0690 23.0 396.0 0.0690 33.0 298.7 0.0690 26.0 (� 411.5 0.0690 33.0 18.0 286 16.4+ 198 f I 16.4+ 198 r - i Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 1. Cooling Load Temperature Difference (CLTD) Fenestration Cs Orientation Shaded Area 0.0 X 0.0 X 72.0 X 4.0X 0.0 x 0.0x 0.0x x x x x GLF + + + + + + + .+ Unshaded Area 1.1 x 1.1 X 0.0 x 0.0X 15.8 x 6.0X 6.0X x x x x GLF 1332 = 'I 1332 = i 17.1 = 16.5- 18.1 = 33.0= 33.0= = = = = Btu/hr (S�Y) 42.5 146 (!i�y 42.5. 146 (S 17.0 1,223 (S 16.4+ 66 (S) 18.0 286 16.4+ 198 f I 16.4+ 198 r Page Total 2 264 Internal Gain Btu/hr Occupants EJ X Occupants x 230 Btuh/oCC. = 920 Equi ment X Dwelling Units X 1 600 Watts/sgft = 1,600 Infiltration: 1.064 X 1.24 X 77.48 X 40 = 4 091 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,896 Latent Gain Occupants F X Occupants x 200 Btuh/oCC. _ Btu/hr 800 Infiltration: 4,771 X 1.241 X 77.48 X 0.00454 = 2 082 Air Latent CFM ELA QW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,882 EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page: 24 of 28 v 4 „9. I RESIDENTIAL ROOM COOLING LOAD SUMMARY I Project Title Date The Nelson Residence 17/23/2007 Room Information Design Conditions Room Name: Bedroom #2 Outdoor Dry Bulb Temperature: 1120F Floor Area: 469 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 1. Cooling Load Temperature Difference (CLTD) Fenestration ICsmntWiw (104) 1 453 275 626 365 613 2 332 Orientation N 467.9 X X X X X x x X X X X x 0.0173 X X x X X x x X X X X X 56.0 = = = = = = = = = = = (N 173.0 0.0690 23.0 (E 275.0 0.0690 33.0 (S1 203.5 0.0690 26.0 0.0 269.0 0.0690 33.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 1. Cooling Load Temperature Difference (CLTD) Fenestration ICsmntWiw (104) 1 453 275 626 365 613 2 332 Orientation Shaded Area X x X x x X X X X X X GLF + + + + + + + + + + + Unshaded Area 1.4 X 36.0 x 6.0 X :X :X .X x x x X x GLF 1332 = = = = = = Btu/hr _(Sky) 0.0 42.5 146 N 0.0 16.4 16.4 590 t 0.0 16.4 33.0 198 Page Total 935 Internal Gain Btu/hr Occupants x Occupants X 230 Btuh/occ. = 920 Equipment P:�4 X Dwelling Units X 1,6001 Watts/sqft = 1,6001 Infiltration: 1.064 x 1.24 x 33.09 X 40 = 1748 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7 534 Latent Gain Occupants X Occupants X 200 Btuh/oCC. _ Btu/hr 800 Infiltration: 4,771 x 1.24 x 33.09 x 0.00454 = 889 Air Latent CFM ELA n w TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,689 EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page: 25 of 28 a (4 ,•• RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date the Nelson Residence .7/23/2007 Room Information Design Conditions Room Name: Great Room/Dining !Outdoor Dry Bulb Temperature: 1120F Floor Area: 2,789 sf ;Outdoor Web Bulb Temperature: 78°F I Indoor Dry Bulb Temperature: 72 OF Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr R-38 Roof f U 2,789.0 X 0.0173 X 56.0 = i 2,702 R-21 Wall - N ( 663 X 0.0690 X 33.0 = I 1 556 R-21 Wall (� _ R-21 Wall 652.9 X 0.0690 X 26.0 = 1,171 R-21 Wall 728.3 X 0.06901 x 33.0 = 1,658 x x = x X - x x = x x = x x x x =1 x x =� Pa a Total 7 ss8 Items shown with an asterisk (') denote conduction through an interior surface to another room. g 1. Cooling Load Temperature Difference (CLTD) Fenestration IFxdWdw (113a) I Shaded Unshaded Orientation Area GLF Area GLF Btu/hr N 0.0 X 16.4 + 12.0 X 16.4 = 197 N 0.0 x 18.0 + 48.0 X 18.0 = 866 N 0.0 x 18.0 + 6.3 X 18.0 = 114 LN 0.0x 18.0+ 6.3X 18.0.= 114 N 0.0 X 37.3 + 60.0 X 37.3 = 2,238 I (� 0.0 x :::l6.4 + 6.3 .x 16.4, = 103 � N 0.0 x 13.5 + 24.0 X 13.5' = 323 (E) 16.0 X 18.0 + 0.0' x 76 = 289 (EE) 0.0 x 37.3 + 48.0 x 72.3 = 3,471 (S) 0.0x 18.0+ 35.8X 18.1_ 649 Page Total 8 363 Internal Gain Btu/hr Occupants F :�4] X Occupants X 230 Btuh/occc. = 920 E uipment 1 X Dwellin Units�X 1 600 Watts/S ft= F-1,600 Infiltration: 1.064 x 1.24 x I 196.79' x 40 = 10 392 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 37,531 Latent Gain Btulhr Occupants 0 X Occupants X 200 Btuh/o CC. = 800 Infiltration: 4,771' X 1.24 X 196.79 X 0.00454 = 5 290' Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,090 EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page: 26 of 28 1 4 •" RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Nelson Residence 7/23/2007 Room Information Design Conditions Room Name: Great Room/Dining (Outdoor Dry Bulb Temperature: 1120F Floor Area: 2,789 sf Outdoor Web Bulb Temperature 780F Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F our racca Orientation Area U -Factor :LTD 1 Btulhr x x x x = x X = X X x x = x x X x = x x = x X = X x = X X = x X Items shown with an asterisk (') denote conduction through an interior surface to another room. F'age TOtal �0 1. Cooling Load Temperature Difference (CLTD) Fenestration Orientation Shaded Area X x X X X x x x x x GLF + + + + + + + + + + Unshaded Area X x X X X x :x x x x GLF 18.1= 17.1 = 19.5 = 33.0 = 33.0 = 39.0 = = = = = = Btulhr U 0.0x 18.0+ 35.8x 649 (S 30.0 17.0 0.0 510 S 200.0 19.4 0.0 3,889 0.0 16.4 16.5 545 (V9V 0.0 16.4 16.5 545 71.1 19.4 18.9 2,120 Page Total 8 257 Internal Gain Btulhr Occupants 4 x Occupants X 230 Btuh/occ. = 920 Equipment El X Dwelling Units x 1 6 10 Wafts/sqft = 1,F;00 Infiltration: 1.064 x 1.24 x 196.79 x 40 = 10 392 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 37,531 Latent Gain Btulhr Occupants�4 x Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 x 1.24 x 196.79 x 0.00454 = 5290 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,090 EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page:27 of 28 A w,", RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title IDate The Nelson Residence 17/23/2007 Room Information Design Conditions Room Name: Bedroom #3 Outdoor Dry Bulb Temperature: 1120F Floor Area: 435 sf Outdoor Web Bulb Temperature 78OF Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 340F Orientation Area X X X X X x X X X X X X U -Factor X X X X X x x X X X X x LTD' = = = = - = = = = = = N) 433.9 0.0173 56.0 294.0 0.0690 23.0 rU (E) 187.0 0.0690 33.0 S 335.5 0.0690 26.0 � 198.0 0.0690 33.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 1. Cooling Load Temperature Difference (CLTD) Fenestration Btu/hr 420 467 426 602 451 2 365 Shaded Unshaded Orientation Area GLF Area GLF Btu/hr S 0.0 X 42.5 + 1.1 x 1332 = 146 S 0.0 X 16.4 + 33.0 x 16.5 = 543 x + X = x + X = x + X = x + X = x + x = x + x = x + x = x + x = x + x = 'age Total 690 Internal Gain Btu/hr Occupants 4 X Occupants X 2 to Btuh/occ. = 920 Equipment 1 X Dwelling Units x 1 600 Watts/sqft = 1 1,6001 Infiltration: 1.064 X 1.24 X 30.69 X 40 = 1621 Air Sensible CFM ELA Z�T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7,196 Latent Gain Occupants IF X Occupants X 200 Btuh/occ. _ Btu/hr 800 Infiltration: 4,771 X 1.24 X 30.69 X 0.00454 = 825 Air Latent CFM ELA QW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,625 EnergyPro 4.3 by EnergySoft User Number: 3665 Job Number: Page: 28 of 28