AR-14-63478-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: AR -14-634
Property Address: 80745 VIA MONTECITO
APN: 772410999
Application Description:
Property Zoning:
Application Valuation: $49,877.80
Applicant:
MONARCH HOMES
49950 JEFFERSON STREET
LA QUINTA, CA 92264
Ce 0 V 4 Q" VOICE (760) 777-7125
FAX (760) 777-7011
COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 7/3/2014
Owner:
HUlVPHREYS
80-745 VIA MOVTECITO
LA QUINTA, CA 52253
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 e Business and Professions Code,
and my License is in full force and effect.
License Class: License No.: C28860
Date_ U `�� Contractor �iJ1 T L
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7631.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed, contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Na
Lender's Address:
Contractor:
MONARCH HONES
49950 JEFFERSCN STREET
LA QUINTA, CA 92264
(760)413-8863
LIC. No.: C2886C
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3790 of the Labor Code, for the performance
of the work for which this permit is issued.
-I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: Policy Number:
_ I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner -o as to become subject to the workers'
compensation laws of California, and ' at, if I should become subject to the
workers' compensation provisions of S of the Labor Code, I shall forthwith
comply w' h those provisions.
Date 1 Applic
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECTAN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,100). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made tothe Building Official for a permit subject to
the conditions and restrictions set forth on -his application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is perfcrmed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related b the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this apolication becomes null and void if work is
not commenced within 180 days from date:of issuance of such permit, or cessation of
work for 180 days will subject permit to carcellation.
I certify that I have read this application an4 state that t bove information is correct.
I agree to comply with all city and county ordinances and s relating to building
construction, and hereby authorize representatives of t s cit o er upon the above-
mentionid property for inspection purposes.
Date: Signature(AppliontorAgen ._ or
FINANCIAL
'DESCRIPTION
ACCOUNT
QTY AMOUNT
PAID
PAID DATE
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400'
0 $61.49
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$17.16
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.12
$0.00
3
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
ADDITION, FIRST 100 SF PC
101-000042600
0
$168.74
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forADDITION: $367.51 $0.00
DESCRIPTION
ACCOUNT,
QTY
AMOUNT
PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$2.00
$0.00
"A= PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forBUILDING STANDARDS ADMINISTRATION BSA: $2.00 $0.00
DESCRIPTION
ACCOUNT
"QTY
AMOUNT
PAID „ .
PAID'DATE
HOURLY PLAN CHECK - YES
101-0000-42600
1
$70.00
$0.00
PAID.;BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forCITY STAFF - PER HOUR. $70.00 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$143.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$47.19
$0.00
;PAID BY
METHOD -
RECEIPT #
CHECK #
CLTD BY
Total Paid forELECTRICAL - NEW CONSTRUCTION: $190.19 $0.00
DESCRIPTION
ACCOUNT
QTY'
AMOUNT
PAID
PAID DATE,
HOURLY PLAN CHECK
10160003428200
$175.00
,PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forHOURLY PLAN CHECK: $175.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
APPLIANCE REPAIR/ALTERATION
101-0000-42402
0
$11.92
$0.00
'PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
APPLIANCE REPAIR/ALTERATION PC.
101-0000-42600
0
$4.77
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
CONDENSER/COMPRESSOR
101-0000-42402
0
$35.75
$0.00
PAID BY
METHOD,
RECEIPT#
CHECK#
CLTD BY
'DESCRIPTION
ACCOUNT"
QTY
AMOUNT
PAID
PAID DATE
CONDENSER/COMPRESSOR PC
101-0000-42600
0
$23.83
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FURNACE
101-0000-42402
0
$35.75
$0.00
PAID BY
METHOD'
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FURNACE PC
101-0000-42600
0
$23.83
$0.00
PAID BY
METHOD '
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
'ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
VENT FAN
101-0000-42402
0
$11.92
$0.00
PAID BY
METHOD..
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
-ACCOUNT :--
QTY
AMOUNT
PAID
PAID DATE
VENT FAN PC
101-0000-42600
0
$4.77
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forMECHANICAL: $152.54 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURE/TRAP
101-0000-42401
0
$59.60
$0.00
PAID BY
'METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURE/TRAP PC
101-0000-42600
0
$59.60
$0.00
PAID BY
METHOD,
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
GAS SYSTEM, 1-4 OUTLETS
101-0000-42401
0
$11.92
$0.00
PAID BY
METHOD -
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT �v`
QTY
AMOUNT
PAID
PAID DATE
GAS SYSTEM, 1-4 OUTLETS PC
101-0000-42600
0
$23.83
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WATER HEATER/VENT
101-0000-42401
0
$11.92
$0.00
PAID BY
METHOD
' RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WATER HEATER/VENT PC
101-0000-42600
0
$7.15
$0.00
PAID BY
METHOD ,„',
RECEIPT #
CHECK #
CLTD BY
:;DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$11.92
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT '”
QTY_
; AMOUNT
PAID
PAID DATE
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$11.92
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forPLUMBING FEES: $197.86 $0.00
DESCRIPTION
ACCOUNT,
QTY
AMOUNT
PAID
PAID DATE
SMI - RESIDENTIAL
101-0000-20308
0
$4.99
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $4.99 $0.00
TOTALS:$1,160.09 $0.00
l— .
Bin #
City of La Quinta
Building &r Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address: $ - % .r
Owner's Name: J�2 3 fi 04W 4
A. P. Number: -777— DO _ 00 :!�-
Address: C/o,Q.-J ru FS
Legal Description:
City, ST; Zip:
Contractor:OAf �e,# 41tss
Telephone: gJ 1) (P s `I - V3 $
Address: 71 'r)ne-msaj r7_ 4"13D
Project Description:
t�ti0 zZa
City, ST, Zip:rpm
Telephone: 4TSI tri �O 3 1
? v ' < :,.:::,.:.::: •::..,...:»»:: •:::.;
7 t /J KIM
State Lic. # :
#;
City Lie.MU
Arch., Engr., Designer:
Address:MMU
OF eUiN
City., ST, Zip:
Telephone:
`iiF:>:>: >:»»
° <'""`°
Construction Type: Occupancy:
State Lic."'°
Project a circle one): New Add'tt Alter Repair Demo
Name of Contact Person: C J S %
�QQ
Sq. Ft.: 5 O
# Stories/:
# Units:
Telephone #.of Contact Person: Q'1 (P39- LQ 3 1
Estimated Value of Project: iD 0 a
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES.
Plan Sets
Plan Check submitted
`'1 ('Z
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
�Qt/
Called Contact Person
G Z
Plan Check Valance.
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
/l4
Mechanical
Grading plan
2od Review, ready for correcti ns/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.1.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Review, ready for correctionstiissue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
Schodl Fees
Total Permit Fees
ENT
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMMAND. AMOUNT:
DATE:
RECEIPT:
CHECK #:
INITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: Humphreys (Residence_(cD The Hideaway)] Date: July 8, 2014
Owner's Name: Phone No.
Project Address: 80-745 Via Montecito, La Quinta, CA 92253
Project Description: Attached Casita
APN: 772-410-999 Tract #: Lot #'s:
Type of Development: Residential XX Commercial Industrial
Total Square Feet of Building Area: 588 Sq. Ft.
Certification of Applicant/Owners: The person signing ce
penalty of perjury and further represents that he/she is authorize
Dated: U Signature:
************************************
bove information is correct and makes this statement under
behalf of the owner/developer.
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PIMJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Project Agreement Existing Not Subject to Fee
17620 65995 Approval Prior to 1/1/87 Requirement
Number of Sq.Ft.
Amount per Sq.Ft.
Amount Collected
588 Sq. Ft.
$3.20
$1,881.60
Building Permit Application Completed: Yes/No
By: Elsa F. Esqueda, Director of Facilities and Maintenance
Certificate issued by: Leticia Torres, Facilities Analyst
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND S)LATEr141ENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90-diy period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
MV:c/mydocs/devfees/certificate of compliance form updated 3-2007 11/2010
I BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
Humphreys Casita
ED
Lot 59D The Hideaway
111ECOV
La Quinta, CA 92253
MAY 12 201 4
Project Designer:
CIVof ���� MEW
rpM
Stracts Architects
51-555 Desert Club Drive, Suite 300
La Quinta, CA 92253
(760) 771-1800
Report Prepared by:
'+ Jon Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Palm Desert, Ca 92211
(760) 200-4780
Job Number:
Date:
5/8/2014 CITY OF LA QUINT,-)
BULDING & SAFETY DEPT.
The EnergyPro computer program has been used to perform the calculations summarized in this compli nce repo t Thhis prog� m, f %pprrQ-aflyd is
0authorized by the California Energy Commission for use with both the Residential and Nonresidential 008 Bu�ta yE nlerlg ��fLcre cr_Standar s.
11 ACTION
This program developed by EnergySoft, LLC - www.energysofticom.
EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 201405-08713:44:52 /D "' C R
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
Room Load Summary
Room Heating Peak Loads
Room Cooling Peak Loads
1
2
3
8
11
12
13
14
C1 -1y OF LA QUINT
BUILDING & SAFETY DEP'
APPROVED
FOR CONSTRUCTION
EnergyPro 5.1 by EnergySoft Job Number: ID: L- User Number: 6712
•
.7
•
PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R
Project Name
Humphreys Casita
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/8/2014
Project Address
Lot 59D The Hideaway La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
588
Addition
n/a
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Pa -t 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity f Features see Part 2 of 5 Status
Roof Wood Framed Attic R-38 588 Ext=R-7.0 Radiant Barrier New
Wall Wood Framed R-21 1,179 New
Slab Unheated Slab -on -Grade None 588 Perim = 103' Existing
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Right (N) 18.0 0.390 0.28 none none Bug Screen New
Front (E) 42.0 0.390 0.28 none none Bug Screen New
Rear (W) 9.0 0.390 0.28 none none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Tlermostat Status
1 Split Heat Pump 8.70 HSPF Split Heat Pump 15.3 SEER Setvack New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
Heat Pump 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New
WATER HEATING t.1 C Y OF LA QI INI
Ot . Type Gallons Min. Eff DistributionDUALD PVC R p,r,,� -Sta_tu A
j-� p-� �•1� Y Y
uct-1.
� F0`� V' I" 1� C �tCrn Y w�U
DATE _
EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014-05-08T13:44:52 —IDS_ BY --------Pace 3 of
J
•
•
•
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Humphreys Casita
Building Type m Single Family ❑ Addition Alon 3
1 ❑ Multi Family ❑ Existing+ Adcition/Alteration
Date
1 5/8/2014
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These itens require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The HVAC System Heat Pump 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must
have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met.
The Roof R-38 Roof(R.38.2x14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and ins�sllation criteria as specified in
Residential Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
CITY OF L.A, QI 11m
BUILDING & SAFETY DEPT.
FOR (.fuCTR(1G:P'
Ener.gyPro 5.1 by Ene rg ySoft User Number: 6712 Run Code: 201405-08713:44:52 I Uf lbw - ___ _ _ RY Page 4 of 4
J
0
C
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Humphreys Casita
❑ Multi Family ❑ Existing+ Acdition/Alteration
1 5/8/2014
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 5.89 4.38 1.51
Space Cooling 79.16 77.40 1.75
Fans 16.41 18.91 -2.50
Domestic Hot Water 0.00 0.00 0.00
Pumps 0.00 0.00 0.00
Totals 101.46 100.70 0.76
Percent Better Than Standard: 0.8%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 100 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 408 42
Fuel Available at Site: Natural Gas (S) 120 0
Raised Floor Area: 0 (w) 408 9
Slab on Grade Area: 588 (N) 312 18
Average Ceiling Height: 12.0 Roof 588 0
Fenestration Average U -Factor: 0.39 TOTAL: 69
Average SHGC: 0.28 Fenestration/CFA Ratio: 11.7%
REMARKS
The Hideaway Country club
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Scott Design and Title 24, Inc,
14
Address 77-085 Michigan Drive Name Jon Scott
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building resign represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building erwelope sealing require
installer testing and certification and field verification by an approved HERS rN—e .
I,TY OF LA
Designer or Owner (per Business & Professions Code) BUILDING-
Stracts Architects & SAFETY DEPT.
Company
�j, g
P
Address 51-555 Desert Club Drive, Suite 300 Name Anton Marinkovich _°_'� P R O V'- D
Cit /State2i La Quinta, CA 92253 r vri l.�IIV� I HL.l (
City/State/Zip p Phone (760) 771-1800 Signed LicehjYNN fte
DATE
EnemvPro 5.1 by Enem ySoft User Number: 6712 RunCode: 2014-05-08T13:44:5 D' Pae 9 of 14
•
1�
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Humphreys Casita
Building Type O Single Family ❑ Addition Aloe
❑ Multi Family ❑ Existing+ Acdition/Alteration
Date
5/8/2014
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof 588 0.022 R-38 7.0 None
0 20 New 4.2.1-A9 Casita
Wall 294 0.069 R-21
10 90 New 4.3.1-A6 Casita
Wall 366 0.069 R-21
100 90 New 4.3.1-A6 Casita
Wall 120 0.069.R-21
190 90 New 4.3.1-A6 Casita
Wall 399 0.069 R-21
280 90 New 4.3.1-A6 Casita
Slab 482 0.730 None
0 180 Existing 4.4.7-A1 Casita
Slab 106 0.730 None
0 180 Existing 4.4.7-A1 Casita
FENESTRATION SURFACE DETAILS
ID Type Area LI -Factor' SHGC
Azm Status Glazing Type Location/Comments
1 Window 18.0 0.390 NFRC 0.28 NFRC 10 New Dual non Metal Tint Casita
2 Window 24.0 0.390 NFRC 0.28 NFRC 100 New Dual non Metal Tint Casita
3 Window 12.0 0.390 NFRC 0.28 NFRC 100 New Dual non Metal Tint Casita
4 Window 6.0 0.390 NFRC 0.28 NFRC 100 New Dual non Metal Tint Casita
5 Window 9.0 0.390 NFRC 0.28 NFRC 280 New Dual non Metal Tint Casita
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window
ID Exterior Shade Type SHGC H t Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len H t Dist Len H t
1 Bug Screen 0.76
F2
Bug Screen 0.76
3 Bug Screen 0.76
4 Bug Screen 0.76
5 Bug Screen 0.76
%.4r
I I BUII'DIN a R Ci,.FFT / nr-
r
FOR CONSTRUCTION
EnergyPro 5.1 by EnergySoft User Number: 6712
RunCode: 2014-05-08713.44:52 Z2: Page 6 cffL4j
_..._ LiI
C.
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF -1 R
Project Name
Humphreys Casita
Building Type ❑ Single Family ❑ Addition Alo-ie
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
5/8/2014
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existing Altered Removed Volume Year Built
Heat Pump 1 Casita
588
7,056
Totals 588 0 01 0
HVAC SYSTEMS
System Name Qty. Heatin Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Heat Pump 1 1 Split Heat Pump
8.70 HSPF Split Heat Pump 15.3 SEER Setback
New
HVAC DISTRIBUTION
System Name Heating
Duct
Coolin Duct Location R -Value
Ducts
Tested? Status
Heat Pump 1 Ducted
Ducted Attic, Ceiling Ins, vented 8.0
❑ New
WATER HEATING SYSTEMS
S stem Name
Ot .
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy Standby
Factor Loss or
or RE Pilot
Ext.
Tank
Insul. R-
Value
Status
CEC Standard
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM PIPING
Control
Hot Water Piping Length
ft
C
0
*C�
c
_
t ------
r.ITV 1 TV
S stem Name OF
dip
�Ler� eh
• ,,_
LQr ip
� laiete
nsul.
hick.
Qty. HP
Plenum
Outside Buried
❑
NBUILDING a
. A
❑
I r a� r �`1lj
❑
1 FORCON
tiIH C
ION
❑
I
Mor
EnergyPro 5.1 by EnerqySoft User Number.' 6712
RunCode: 201405-08T13:44;52—. ID:
7 of 14
J
4
4
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF-1 R
Project Name
umphreys Casita
Date
5/8/2014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R, CF-1 R-ADD, or CF-
1 R-ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R
Form with plans.
Building Envelope Measures:
116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF-1 R Form.
*§1 50a : Minimum R-19 insulation in wood-frame ceiling orequivalent U-factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value.
150(c): Minimum R-13 insulation in wood-frame wall orequivalent U-factor.
150(d): Minimum R-13 insulation in raised wood-frame floor orequivalent U-factor.
150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory-built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible operable, and tight-fitting damper and or a combustion-air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release
valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water-heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 si, meets the requirements of Standards Table
123-A.
150(4)3A: Insulation is protected from damage, including that due to sunlight, moistu e e il'i m nt amtetJance and Wind'
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a v`apoi 6tar ftgor is eaclos d-enitirely_ n,- T.
conditioned space. 1 l� h'
150(j)4: Solar water-heatingsystems and/or collectors are certified b the Solar Ran an Ce fifica on Cor 1 '!' n.r
r1J11 UUNSTRUCTION
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-05-08T13:44. SATE 13Y Page of 14
J
4
4
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R
Project Name
Date
umphreys Casita
1 5/8/2014
§150(m)1: All air-distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply-air and return-air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-dosure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductons in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily acces3ible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant anc provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilatio-ri and Acceptable Indoor Air
Quality in Low-Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies wish the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card wth operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 .
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is rn) lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line-
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw-base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling Units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi-scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual-on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than-20-watts—of power per linear foot of
illuminated cabinet.
OUIN TA
BUILDING & SAFETY DEPT.
FOR CONSTpi IrTinta
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201405-08T13:44:52 /D: Page 9114
DATE �__ gY I
MANDATORY MEASURES SUMMARY: Residential Pa e 3 of 3 MF -1 R
Project Name
Date
umphreys Casita
5/8/2014
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathroom 3, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low eficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential builcing or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables tie photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130 131 134 and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements cf 119.
EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 201405-08T13:44:52 ID: Page 10 of 14
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Humphreys Casita
5/8/2014
System Name
Floor Area
Heat Pump 1
588
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL
CFM
578
0
COOLING FEAK
COIL HTG.
PEAK
Heating System
Sensible
; Latent CFM
Sensible
Output per System 51,000
9,2961
1,650 277
10,759
Total Output Btuh 51,000
0
Output Btuh/s ft 86.7
537
411
Cooling System
0
0
Output per System 24,000
0
0 0
0
Total Output Btuh 24,000
01
1,650
0
Total Output Tons 2.0
537
411
Total Output Btuh/s ft 40.8
Total Output s ft/Ton 294.0
1 10,369
F,1,582
Air System
CFM per System
800
HVAC EQUIPMENT SELECTION
Airflow cfm
800
Carrier 25HCC524/FX4DNF025
13,939 5,913
31,853
Airflow cfm/s ft
1.36
Airflow cfm/Ton
400.0
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
13,939 5,913
Aug 3 PM
31,853
Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 72 OF
72 OF 109 OF
O
Outside Air
0 cfm Supply Fan
Heating Coil
108 OF
800 cfm
11It
I ROOM
72 OF
72 OF
I
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 71/60°F 71/61°F 54/53°F
Outside Air
c
0 cfm
Supply Fan Cooling Coil
800 cfm
CITY°F
OF !�
QUiLDINC67;4ISA R0'
71 /60°F
APPROVED 70/ OF
Fnp
�DATF=
EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 201405-08713:44:.52 /D: a 11 of 14
'•• •�� �'
ProjectDate
Humphreys Casita
51812014
Name
Heat Pump 1
FloorSystem •,
..
ROOM LOAD SUMMARY
COIL COOLING PEAK
®
i
MUM
PAGE TOTAL
TOTAL����
•-�
0
ROOM HEATING PEAK LOADS
Project Name
Humphreys Casita
ROOM INFORMATION
Room Name
Floor Area
Indoor Dry Bulb Temperature
Conduction
R-38 Roof(R.38.2x14.16)
R-21 Wall
Dual non Metal Tint
Slab -On -Grade
DESIGN CONDITIONS
Casita Time of Peak
588.0 ft2 Outdoor Dry Bulb Temperature
72 OF
Area
588.0
1,179.0
69.0
perim = 103.0
Date
5/8/2014
Jan 1 AM
26 OF
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CT 'F
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
0.0220
46
0.0690
46
0.3900
46
0.7300
46
Btu/hr
595
3,742
1,238
3,459
Items shown with an asterisk (') denote conduction through an interior surface to another room Pa7APPROVED
e Total 9,034
Infiltration:[ 1.00 X 1.064 X 588 X 12.00 X 0.30 _ 11?�125
Schedule Air Sensible Area Ceiling Height ACHi I �]�Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 59
5.1 by EnergySoft User Number: 6712 RunCode: 201
•
•
0
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Humphreys Casita
5/8/2014
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Casita
Outdoor Dry Bulb Temperature
112 OF
Floor Area 588.0 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
R-38 Roof(R.38.2x14.16) (N) 588.0 X 0.0220
X
56.0 =
724
R-21 Wall (N) 294.0 X 0.0690
X
24.3 =
494
R-21 Wall (E) 366.0 X 0.0690
X
32.6 =
822
R-21 Wall (S) 120.0 X 0.0690
X
27.1 =
224
R-21 Wall 399.0 X 0.0690
X
32.4 =
892
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
3,156
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area
GLF
Btu/hr
Window (N) 0.0 X 18.2 +
18.0
X 20.2 =
363
Window (E) 0.0 X 18.2 +
24.10
X 34.2 =
821
Window (E) 0.0 X 18.2 +
12,0
X 34.2 =
410
Window (E) 0.0 X 18.2 +
60
X 34.2 =
205
Window (lam 0.0 X 18.2 +
910
X 33.1 =
298
X +
X -
X +
X -
X +
X -
X +
X -
Page Total
2,098
Internal Gain
Btu/hr
Occupants 4.0 Occupants X 230
Btuh/occ.
=
920
Equipment 1.0 Dwelling Unit X 1,600
Btu
=
1,600
Infiltration: 1.064 X 0.94 X 36.41 X 42 =
1,522
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
9,296
Latent Gain
Btu/hr
Occupants 4 0 Occupants X 2yp�
800
Infiltration: 4,771 X 0.94 X 36.41 x 0.00523 =
CIFY
BUILDING
OF L�1 QI
& SAFE"
I
Air Sensible CFM ELA AW
APPROVED
`- •
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
S TRUCTION,
650
EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 201405-08T13:44:52 I
Pae 14 of 14