Loading...
05-5083 (SFD)1 . 4 P.O. BOX 1504�� VOICE 760 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA,'CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760),777-7153 t . BUILDING PERMIT Date: 3/09/06 Application Number. "05=000050'83. Owner. Property Address: `8.0175 VIA MIRASOL DON & VALERY NEWMAN APN: 772-430-010- - - 441 FALCON VIEW ST. Application description: DWELLING - SINGLE FAMIL E 0 INDIAN WELLS, CA 92210 Property Zoning: LOW DENSITY' RESIDENTIAL D Application valuation: 530260 q • ®� p p yy .2006 MAR' 10. Contractor: Applicant: Architect or fn me r: KG CONSTRUCTION. (,`�jY.�LAQu{� µ73416- SILVER MOON TRAIL , �INAPICE®EPT. PALM DESERT, CA 92260 '. (760) 275-4920 y Lic. No.: OOR SQUARE FOOT Lic. No.: 819174' - - - - - - - - 7 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --- - - LICENSED CONTRACTOR'S DECLARATION - • - WORKER'S COMPENSATION DECLARATION , I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury oAe of the following declarations: - ` Section 7000) of Division 3 of the Business and Professionals Code, and y License is in full force and effect. - _ I-haveand will maintain a certificate of consent to self-insure for workers' compensation, as provided ` Licens clas : B - License No 819 74 for by Section 3700 of the Labor: Code, for the performance of the work for which this ,permit is // / /% _ issued. G�,Q -b -.Contractor. - yam✓ _ (.have and will maintain workers' compensatidninsurance, as required by Section 3700 of the Labor - _ - Code, for the performance of the work for which this permit is issued. My workers' compensation - - �- - - - OWNER-BUILDER DECLARATION - - insurance carrier and policy number are:- F' I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier EXEMPT Policy Number EXEMPT • " '� - following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a'permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any - construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, - permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State - and agree that, if I should become subject to the workers' pens - n provisions'of Section - - License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the Labor Code, I shall f ith comply with t e pro ' o _ + �.e that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by/!yt any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:- t. ( 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and ^= •��'� the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The - WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL - Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100;000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner-builder will have the burden of proving that he or she did not build or - improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT - - (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application.. ' .. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.).. whose benefit work is performed under or pursuant to any permit issued as a result of this application, I—) I am exempt under Sec. B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. Date: Owner:. - 2. ' Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit to cancellation. hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the - I certify that I have read this application and state that the above information is correct. I agree to comply with all - work for which this permit is issued (Sec. 3097, Civ. C.). city and county ordinances and state laws relating to building construction, and hereVagthorize representatives of this cont to nter upon the above-mentioned property fo ection purpose Lender's Name: - ffDalA ignature (Applicant or-AgeLender's Address: LQPERMIT - Application Number . . 05-00005083 Permit . . BUILDING PERMIT Additional desc . Permit Fee . . 2132.50 _ Plan Check Fee 1386.13 Issue Date Valuation 530260 Expiration Date 9/05/06 Qty *Unit Charge Per Extension BASE FEE 2039.50 31.00 3.0000 -THOU BLDG 500,001-1,000,000 93.00 -PermitELEC-NEW RESIDENTIAL Additional desc :, Permit Fee 263.54. Plan Check Fee 65,.89 Issue Date . . Valuation 0 Expiration Date 9/05/06 • Qty. Unit Charge Per Extension BASE FEE 15.00 6120.00 .0350. ELEC NEW RES - l OR 2 FAMILY 214.20 967.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL.. 19.34 1.00 -15.0000 EA ELEC TEMPORARY POWER POLE 15.00 -------- Permit, GRADING PERMIT Additional desc . Permit Fee 15.00 Plan Check Fee .00 Issue Date -Valuation 0 Expiration Date 9/05/06 - - Qty Unit Charge .Per. Extension - BASE FEE 15,:00 ------------------------ -------------- -----------.---------------- ---------- -------Permit 'Permit" MECHANICAL = Additional desc . Permit.Fee 157.00 Plan Check Fee 39.25 Issue Date Valuation"' 0 Expiration Date 9/05/06. Qty Unit Charge Per Extension BASE FEE 15.00 5:00 9.0000 EA MECH FURNACE <=100K 45.00 5.00 9.0000 EA MECH B/C <=3HP/100K BTU 45.00 7.00 6.5000 EA MECH VENT F.AN 45.50 1.00 -------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 7 --------------------------- 6.50 Application Number 05-00005083 Permit PLUMBING Additional desc . Permit Fee 241.50 Plan Check 'Fee `. 60.38 Issue- Date Valuation 0 Expiration Date 9/05/06 Qty Unit Charge .,Per Extension BASE FEE 15.00 25.00 6.0000 EA PLB FIXTURE 150.00 1.:00•"_ 15.0000 EA PLB BUILDING SEWER 15.00 3.00 7.5000 EA PLB WATER.HEATER/VENT 22.50 1.00 3.0000 EA, PLB WATER INST/ALT/REP 3.00 , 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 16.00 .7500 EA PLB GAS PIPE >=5 12.00 1.00 15.0000 EA PLB GAS METER 15.00 ---- - ---- -- ------ Special Notes and Comments-. --------- 6120 SQ. FT. SFD THIS PERMIT DOES NOT. _ INCLUDE -POOL & SPA, BLOCK WALLS OR DRIVEWAY APPROACH.February 15,,2006 6:58:33 AM jjohrison - - -- Other Fees ---------------------------------- ART IN PUBLIC PLACES -RES ---- - - - - -- --- 825.65. DIF COMMUNITY.CENTERS-RES 74.00 DIF CIVIC CENTER - RES 480.00 ENERGY REVIEW FEE 138.61 DIF .FIRE PROTECTION -_RES 140.00 , GRADING PLAN.CHECK FEE .00 DIF LIBRARIES "- RES 355.00 DIF.PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION'_(SMI). -RES 53.02 DIF STREET MAINT.FAC-RES.. 67.0.0 , DIF TRANSPORTATION -.RES 1666.00 / Fee summary Charged Paid Credited Due Permit Fee Total 2809.54 .00 .00'' x'2809.54 Plan Check Total 1551.65 500.00 .00 1051.65 Other Fee Total 4713.28 .00 .00 4713.28 Grand Total 9074;47 500.00 .00. 8574.47 ' LQPERMIT . - 1 Coachella Valle Unified School District ' Valley This Box For District Use Only 83-733 Avenue 55, Thermal, CA` 92274' DEVELOPER FEES PAID (760j'398-5909 —.Fax (760) 398-1224 r . AREA: '' - - AMOUNT, ' J LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATF.• - ti - RFCFIPT• r..HF.CK M- INITIAI.S- CERTIFICATE'OF COMPLIANCE (California Education Code 17620) Project Name: Date: February 17, 2006 Owner's Name: M/M Don Neuman Phone No. Project Address: 80-175 -Via.Mirasol La-Quinta, CA Project Description: 1 SFD , APN: 772-430-010 Tract#: Lot #'s: Type of Development: Residential WX _ Commercial • Industrial Total Square Feet of Building Area: 6,120 s4. ft.' ^ Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: February 17, 2006' Signature SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT -HAVE BEEN OR WILL BE SATISFIE_ D IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) , Education Code, Gov. Code Project • Agreement Existing Not Subject to -Fee 17620 65995. 'Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 6,120 , Amount per Sq.Ft. $2.88 Amount Collected $17,625.60 Building Permit Application Completed: Yes/No , By: Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: Elvira Mattson, Office Technician Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective'January 1; 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, - in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the -payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally; the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy: As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may: be granted. At such time as this Certificate expires, if a. building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. �:!':c•:',mdocsidvi, c iecrtiiic ite l f cornplimce ii)rm ulbles'1`t:1 USG.doc ,`- 1/16/03'T RECORDING REQUESTED BY: SOUTHLAND TITLE - INLAND EMPIRE (Title) 0p3/09/2006 AND WHEN RECORDED MAIL TO: Conformed Copy Has not been com Don Neuman pared with original '9// /:Alcow KCL -ti Larry U Wrd County of Riverside PAI -11'1 lbefee- (�A , -i22 Assessor, County Clerk 8 Recorder Order No.: Escrow No.: SPACE ABOVE THIS LINE IS FOR RECORDER'S USE ::-.GRANT DEED THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX IS NONE [ ] computed on full value of property conveyed, or [ ] computed on full valueless value of liens or encumbrances remaining at time of sale. ] unincorporated area - [ XX ] City of La Quints , FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND La Quinta Partners, LLC, a Delaware, Limited iability Company hereby GRANT(S) to Valery Neuman and Donald Neuman, Wife and'Husband as Community Property with Rights of.Survivorship the following described real property in the County of Riverside, State of California See Legal Description attached hereto and incorporated herein as Exhibit "A" Dated: March 7, 2006 STATE OF CALIFORNIA ` COUNTY OF' l v� as r �� } ss ND La Quinta Partners, LLC a Delaware on moo t— before me limited liiability company all pets Wally appeared By: Nationwide Realty Investors, Ltd. An L, Ohio, Limited Liability comp , its managing ebpwpl.. personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) 3 is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their." y: Oseph L. Arenson, authorized authorized capacity(ies) and that by his/her/their signature(s) representative on the instrument the person(s), or the entity upon behalf of: which the person(s), acted, executed the instrument.— CONNIE C6NCETTO WITNESS m a d and official se COMM. # 1417229 V BI NOTARY PUC - CALIFORNIA Signature - .•_ RNERSIDE COUNTY Signature of Notary F My Commsslon ExI*96 May 20071 ''(This area for official notary seal) MAIL TAX STATEMENTS AS DIRECTED ABOVE i EXHIBIT "A" PARCEL 1 LOT 10 OF AMENDMENT NO. 2 TRACT NO. 29894-2, IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA AS SHOWN ON A MAP FILED IN BOOK 359, PAGES 68 THROUGH 82, OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. TOGETHER WITH THAT PORTION OF LOT "J" OF TRACT NO. 32453 AS SHOWN ON A MAP FILED IN BOOK 372, PAGES 10 THROUGH 18, OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: TRANSFER PARCEL BEGINNING AT THE SOUTHEASTERLY CORNER OF LOT 10 OF AMENDMENT NO. 2 TRACT NO. 29894-2 AS SHOWN ON A MAP FILED IN BOOK 359, PAGES 68 THROUGH 82, OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY; THENCE ALONG THE SOUTHERLY PROLONGATION OF THAT CERTAIN COURSE IN THE GENERALLY EASTERLY LINE OF SAID LOT 10 DESCRIBED AS "S12029'30"E 129.92' ", SOUTH 12029'30" EAST, 12.00 FEET; THENCE LEAVING SAID SOUTHERLY PROLONGATION SOUTH 67022'41" WEST, 111.88 FEET TO THE SOUTHEASTERLY PROLONGATION OF THE SOUTHWESTERLY LINE OF SAID LOT 10; THENCE ALONG SAID SOUTHEASTERLY PROLONGATION NORTH 20°24'55" WEST, 33.28 FEET TO THE SOUTHWESTERLY CORNER OF SAID LOT 10; THENCE LEAVING SAID SOUTHEASTERLY PROLONGATION AND ALONG THE GENERALLY SOUTHERLY LINE OF SAID LOT 10 SOUTH 87019'03" EAST, 32.59 FEET; THENCE CONTINUING ALONG SAID GENERALLY SOUTHERLY LINE NORTH 72031'58" EAST, 83.58 FEET TO THE POINT OF BEGINNING. THE ABOVE DESCRIBED PARCEL CONTAINS 0.660 ACRES, MORE OR LESS. PARCEL 2 LOT "J" OF TRACT NO. 32453, IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA AS SHOWN ON A MAP FILED IN BOOK 372, PAGES 10 THROUGH 18, OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY, EXCEPTING THEREFROM THAT PORTION BEING MORE PARTICULARLY. DESCRIBED AS FOLLOWS: TRANSFER PARCEL BEGINNING AT THE SOUTHEASTERLY CORNER OF LOT 10 OF AMENDMENT NO. 2 TRACT NO. 29894-2 AS SHOWN ON A MAP FILED IN BOOK 359, PAGES 68 THROUGH 82, OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY; THENCE ALONG THE SOUTHERLY PROLONGATION OF THAT CERTAIN COURSE IN THE GENERALLY EASTERLY LINE OF SAID LOT 10 DESCRIBED AS "S12029'30"E 129.92' ", SOUTH 12029'30" EAST, 12.00 FEET; THENCE LEAVING SAID SOUTHERLY PROLONGATION SOUTH 67022'41" WEST, 111.88 FEET TO THE SOUTHEASTERLY PROLONGATION OF THE SOUTHWESTERLY LINE OF SAID LOT 10; THENCE ALONG SAID SOUTHEASTERLY PROLONGATION NORTH 20°24'55" WEST, 33.28 FEET TO THE SOUTHWESTERLY CORNER OF SAID LOT 10; THENCE LEAVING SAID SOUTHEASTERLY PROLONGATION AND ALONG THE GENERALLY PLAT TO ACCOMPANY SHEET 1 OF 1 SHEETS LEGAL DESCRIPTION C v H I Q I T 11 B 11 ` 10' WIDE Ate. V. 3 \ \' So' / 4 LINE TABLE �:' �'9p\� / 10' WIDEQC3��G UNE BEARING LENGTH 'Q�A'" L1 N 87.15'03" W 2.59' \>:9, \ L2 N 49'08'02" W 2'4 !y �154 LEGEND / /. (c2)� EXISTING LOT LINE TO N 10'-32Rp',0• BE ADJUSTED EXISTING LOT LINE TO REMAIN 2 NEW LOT LINE .�''� 5 L r TiJ JDAvjz..NT` No. 2 TRACT No. 20801-2 1`0lop 1 s ARCEL MERGER No. 6- 4S3 UNE A VMIENT N0. PARCEL 1 N �` s.. «:,r.ea,,{ . 88 a 'Y,ii : i J1 J 0.660 ACRES • OVED BY qm 0FjA A ,,Tj, I L0 T J �l ITV 8E�►ELQRI T EP ENf N �dreuJ. Mow 9&, -3.06#; LOT LINE TO BE REMOVED Wi N PARCEL 2 �. •5e _ 2 5LOT J SCALE: 1" = 60' �� l. /�$3'S8,',, 00� •, � TRACT NO. 37453 NEW .LOT LINE u'w W 1� ' Ij]B: 372/10-10 �•�'� 61,22 A," LEGEND CON'T. s. TRANSFER (XXXX) INDICATES RECORD DATA PER AMENDMENT 4�p NO. 2 TRACT NO. 29894-2 M.B. 359/68-82 2,079 SQ.FT. a y 1 INDICATES A 10 WIDE PUBLIC UTILITY EASEMENT PER AMENDMENT NO. 2 TRACT NO. 29894-2 No. 7842 M.B. 359/68-82 * Exp. 12/31/06 0 INDICATES A 12' WIDE LANDSCAPE EASEMENT PER AMENDMENT NO. 2 TRACT NO. 29894-2 F OF CAL�F� M.B. 359/68-82 3 �NbICATES A 10' WIDE STORM DRAIN EASEMENT PER AMENDMENT NO. 2 TRACT NO. 29894-2 PREPARED BY ME OR UNDER MY DIRECTION: M.B. 359/68-82 INDICATES A 10' WIDE CVWD WATER EASEMENT PER AMENDMENT NO. 2 TRACT NO, 29894-2 2 M.B. 359/68-82 �INDICATES A 10' WIDE VERIZON EASEMENT DEAN J. BOULDIN, P.L.S. 7842 DATE 'Q PER INSTRUMENT NO. 2005-0562133 O.R. EXP.,12-31-06 RECORDED JULY 14, 2005 CURVE TABLE CURVE DELTA, RADI S LENGTH Cl 01'1 6" 21 d.00' 4 .42' (C2) 01'59!*r 5MD' 1. ' 0 8212:59" 31,00' 44 3' ` 10' WIDE Ate. V. 3 \ \' So' / 4 LINE TABLE �:' �'9p\� / 10' WIDEQC3��G UNE BEARING LENGTH 'Q�A'" L1 N 87.15'03" W 2.59' \>:9, \ L2 N 49'08'02" W 2'4 !y �154 LEGEND / /. (c2)� EXISTING LOT LINE TO N 10'-32Rp',0• BE ADJUSTED EXISTING LOT LINE TO REMAIN 2 NEW LOT LINE .�''� 5 L r TiJ JDAvjz..NT` No. 2 TRACT No. 20801-2 1`0lop 1 s ARCEL MERGER No. 6- 4S3 UNE A VMIENT N0. PARCEL 1 N �` s.. «:,r.ea,,{ . 88 a 'Y,ii : i J1 J 0.660 ACRES • OVED BY qm 0FjA A ,,Tj, I L0 T J �l ITV 8E�►ELQRI T EP ENf N �dreuJ. Mow 9&, -3.06#; LOT LINE TO BE REMOVED Wi N PARCEL 2 �. •5e _ 2 5LOT J SCALE: 1" = 60' �� l. /�$3'S8,',, 00� •, � TRACT NO. 37453 NEW .LOT LINE u'w W 1� ' Ij]B: 372/10-10 �•�'� 61,22 A," LEGEND CON'T. s. TRANSFER (XXXX) INDICATES RECORD DATA PER AMENDMENT 4�p NO. 2 TRACT NO. 29894-2 M.B. 359/68-82 2,079 SQ.FT. a y 1 INDICATES A 10 WIDE PUBLIC UTILITY EASEMENT PER AMENDMENT NO. 2 TRACT NO. 29894-2 No. 7842 M.B. 359/68-82 * Exp. 12/31/06 0 INDICATES A 12' WIDE LANDSCAPE EASEMENT PER AMENDMENT NO. 2 TRACT NO. 29894-2 F OF CAL�F� M.B. 359/68-82 3 �NbICATES A 10' WIDE STORM DRAIN EASEMENT PER AMENDMENT NO. 2 TRACT NO. 29894-2 PREPARED BY ME OR UNDER MY DIRECTION: M.B. 359/68-82 INDICATES A 10' WIDE CVWD WATER EASEMENT PER AMENDMENT NO. 2 TRACT NO, 29894-2 2 M.B. 359/68-82 �INDICATES A 10' WIDE VERIZON EASEMENT DEAN J. BOULDIN, P.L.S. 7842 DATE 'Q PER INSTRUMENT NO. 2005-0562133 O.R. EXP.,12-31-06 RECORDED JULY 14, 2005 Tilt .-. :a P.O. Box 1504 . LA QUINTA, C.AI.IPONtiIA• 92247-1504 78-495 CAIA_F: TAMPICc> (760) 777-7000 LA QUINTA,, CALIFORNIA 922.53 FAX (760) 777-7101. March 3, 2006 Valery Neuman and Donald Neuman 752 Elk Clover Circle Palm Desert, CA 92211 SUBJECT: LOT LINE ADJUSTMENT 06-453 LETTER OF APPROVAL Dear Mr. and Mrs. Neuman, Attached with this letter are the original approved" revisions concerning Lot Line Adjustment LLA 05-453. Based on zoning compliance and correctness of the property descriptions, the- City has - approved your request . for a Lot Line Adjustment. r Attached is the original -Preliminary Title Report and Exhibits A and B. Please complete the grant deed and have these . documents recorded with the County Recorder and provide us a copy of the recorded documents for our files. Until the recorded copies . are received, the lot Line Adjustment is not complete. This letter shall be presented to the County Recorder, as official verification that the City has approved the adjustment and requests its recordation. By execution of this approval,' -the applicant agrees -to indemnify, defend and hold harmless the City of La Quinta from any legal claim or litigation arising out of the City's approval of this Lot Line Adjustment. Should you have any questions, feel free' to contact me at (760) 777-7125. Sincerely, , Idw J. Mogensen Associate Planner Enclosures AJM: ajm �.., ­, avo0 14:00 1bfJb/QJii8 .. PAGE 01 r FIDEIJ'I Y NATIONAL TITI:E G0MpAI4Y" "'•`' , . C SUBDIVISION DEPARTMENT p„ OOC is 2®0��07366'T4 WHEN RECORDED MAIL TO:,' @8/16/2004 0a:00a Fee:19.00 Mr. and Mrs. Neuman •, g` `Page i of 5 ooc T Tax Pard 752 Elk Clover Circle z t Recorded In Offielal Records , '.• County of Riverside Palm Desert; CA 92211nary C. orso Assessor', County Glork 8 Recorder, } �� III lilt 11111 MAIL TAX STATEMENT TO: SAME AS ABOVE APN: 772-430-024-3` TRA: 020-160 � Doc " M S - 'U RAGE &LE. O� '• PGOA NOLO" BMi IwSC.. EXAM . A R COPY IONO P.EFUNO NU•16 UMENT TRANSFER TAX S 696.30 - XX Computed on the consideration or value of property conveyed: OR �J Computed on the consideration or value less liens or encumbrances remaining at the time of sale: . Signature,of Declarant or Agcrit dctermining tax —.Firm Namc yGRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company ("Grantor"), hereby r GRANT(S) to Valery Neuman and Donald Neuman, Wife and Husband as Community Property with Rights of Survivorsbip ("Grantee"), the real property located In the City of La Quinta, County of Riverside, State of Catifornia, described as. See Legal Description. attached .hereto an..d i.iicorporated herein. as Exlvbit "A". SUBJECT TO all matters of record including without limitation, the covenpants and , agreements described'in Exhibit "A" attached hereto. Dated: p ND LA QUTNTA PARTI�TERS, LLC, a Delaware limited liability company By: Nationwide Realty Investors, Ltd. an Ohio limited liability company its managing m er. B 11 _ Joseph L. Arenson Authorized Representative , ` u r. •f 4 U Ionorudttd PAGE 03 - i EXHIBIT "A„ t. Legal Description Parcel No. 1: Lot 10 (the "Lot') of Amendment No. 2 .Tract No. 29894-2 as shown on Subdivision Map (the ' "Map") recorded on December 12, 2002, in Book 359, Pages 68 to 82, inclusive, of Maps, in the Office of the Riverside County Recorder. EXCEPTING AND RESERVING THEREFROM TO GRANTOR, and its successors, assigns, invitees, licensees and employees, together with the right to grant and trabsfer all or a " portion of the same, all. easements and rights for access, ingress, egress, encroachment, maintenance, drainage, support, and for other purposes over the Association Mairitenance Areas and other portion of the Lot, .reserved to Grantor in the following :instruments: 1. The Amended and Restated Declaration of Covenants,- Conditions:and Restrictions and Reservation of Easements for The Hideaway Owners Association (as amended or supplemented, the "Declaration"), recorded on December 13, 2002, as Instrunknt No. 2002- 745938, of Official Records of Riverside County, California (the "Official Records");, 2. The Supplementary Declaration of Annexation of Property, recordled on March 21, 2003, as Instrument No. 2003-201647, of Official Records of Riverside Country, California. FURTHER, ESERVING THEREFROM, the right to enter the Lot for a term of twelve (12) months following the recordation of this Grant Deed, to complete and repair any improvements or landscaping located thereon as determined necessary by Grantor, in its sole discretion, in order to comply with requirements for the recordation of the Final Tract Map, the grading ofsaid- Tract and/or incompliance with the requirements of applicable governmental agencies. Such entry by Grantor. shall be preceded by reasonable notice to Grantee before such entry. If this reservation of right of entry .is not complied with by Grantee, Grantor may enforce ' 'this tight of entry in a court of law. Grantee shall be responsible for all damages arising out of. ' said breach including attorneys' fees and court costs.' This reservation of right o.f entry shall' automatically expire twelve (12) months from. the recordation of this Grant Deed. . Parcel No. 2: 9 > Nonexclusive easements .for access, ingress, egress, drainage, maintenancie, repairs and for other purposes, all as described in the Declaration.', SUBJECT TO: I. Non delinquent`general, special and supplemental: real property takes and assessments. y IbkJb I4.il Id - PAGE e4 2r All. other covenants, conditions, restrictions, reservations, easements, rights and rights-of.--way of record including, without imitation, the Declaration and the Map for Tract No. 29894-2. Grantee, by acceptance and: recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in tlt:is Grant Deed, (b) grants to Grantor and The Hideaway Owners Association such powers and rights as are set forth in the Declaration, and (c) accepts, covenants and agrees to be bound by and assume performance of all of the applicable provisions and requirements set forth in the Declaration, including Section 1.3.15 establishing the procedure for resolving disputes with Grantor, and the notice, which provisions and requirements are acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be performed by Grantee under the Declaration. The restrictions on use and occupancy. of the Lot are set forth in the Declaration to which this Grant Deed is specifically and expressly made subject. GRANTEE HEREBY ACCEPTS AND APPROVES THE FOREGOING, granting unto Grantor and The Hideaway Owners Association. such.powers and .rights which are set ..forth in the Declaration defined above, on - SqJM AgR ,01 ; 2004. r' 01( -Ooo6 Donald Neuman Vale Neu STATE OF Li FnPfil/4 ) " ss. COUNTY OF I exStnt } On wl 2004, before me, the undersigned, a notary public in and for said State, personally appeared Donald Neuman and Valery Neuman, personally known to me (or proved to me on the basis of satisfactory evidence) to be the persons whose names are subscribed to the within instrument and acknowledged to me that they executed the same in their authorized.capacities, and that by their signature on the instrument the persons, or the entity upon behalf of which the persons acted, executed the instrument. 11TT'T%T1C0Q 1 i/V TT A ATT% A ATT% r%L•LTr1T A T Qtr. A T.. .. .y+.,u. is • " {....-•fin y y CAL-SURV INC. "o S , A California Land Survey Corporation March- 27, 2006 ENGINEERING DEPARTMENT - `^ CITT OF LA QUINTA - 78-495 Calle Tampico La Quinta, CA 92253 r Re: „Neuman- Residence X8.0'=-L75UaMraso a La'Quint, _a C 92253 SCH0211 City Engineer: 41 Based on.a field survey.+of the subject site; I observed the concrete forms for location and grade, and' found- the- -top of form" grade to bei measured ate-' 1018 45-, in" substantial `conforrnance vertical,) with the finish"--f-loor` grade ='of the approved precise grading plan. Said forms do not encroach within the building setbacks. If you have any questions or require a copy of my field notes please contact me at the number shown below. Sincerely,, tp k.AND SU iN CAL-SURV, INC. G<c. o LS 5491 N ;RES 9/36&0 Andrew Y. Orosco-VL.S.5491`. Project Manager OFCAL�F :rJ.... _ ..x s. -- CY .L `iFs L�1_il- ' iJt i • 1Z`]G "Surveying Today For Califoinia's �Toiito=row" P.O.BOX 1249 o' RIVEASIDE, CALIFORNIA "16= 92502' • (9b1) 7`88-8357 P.O.BOX 11153 • PALM DESERT ,"CALIFORNIA • 92255 •`(877)788=8357. 4 Q^rtifi'ca fe of uccuplacyn i O 114 INCORPORATED � 1982 c� OF9`��' p Building SafetyDepartment S ,& ; 4 g ' This -Certificate is issued pursuant to the requirements of Section '109 of the California Building E P ! Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building z construction and/or use. I BUILDING ADDRESS: 80-175 VIA MIRASOL ' Use classification: SINGLE FAMILY DWELLING r Building Permit No.: 05-5083 ' I Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL ?} t l fit Owner of Building: DON & VALERY Address: 441 FALCON VIEW ST. { { City, ST, ZIP: INDIAN WELLS, CA 92210 s By: EDDIE MUIR I Date: JUNE 8, 2007 Building Official r - .POST IN A CONSPICUOUS PLACE 6 � 6 December 13, 2005 ,:. Project No. 544-5951 Y 05712-1158 Mr. Don Newman c/o Mr. Ken Schmale P. O. Box 1372 Palin Desert, California 92261 Project: The Hideaway Lot 10 , 80-175 Via Mirasol La Quinta, California Subject: Geotechnical Update Ref: Report of Observations and Testing During Fine Grading prepared by Sladden Engineering dated August 13, 2003, Project No. 544.2199, Report No. 03.04-225. Geotechnical Update prepared by Sladden Engineering dated February2003, Project No. 544-2199, Report No. 03.-02-106, Geotechnical Engineering Report prepared by Earth Systems Consultants dated September 22, 2000, File No, 0711740, Report No. 00-09-772. Report of Testing and Observation luring Rough Gradingprepare;d by )Earth Svsterns Southwest dated August 28, 2002, Tile No: 07117-11;'ReportNo. 01.-07-71 R. As requested, we have reviewed the above referenced geotechnicalreports as they relate to the design and e(wistruetion of the proposed single family residence. The project site is identified as Tot 10 at 80-175 Via Mirasol within Phase 1B of the Hideaway Golf Club development in the City of La Quinta, California. It is our,understanding that the prupused residence will be a relatively lightweight wood frame structure supported by conventional shallow spread footings and concrete slabs on grade. The lot was previously graded during the rough grading of the Hideaway project .site and was recently regraded. The rough grading included overexcavation of the native surface soils along with the placement of .engineered fill material' to construct the building pads. The recent regrading included processing the surface soils along with minor cuts and fills to construct the individual building pads. Some additional overexcavation was'perforined in areas where the building envelopes were reconfigured. The initial site grading is summarized in the referenced . Report of Observations and Testing During 'Rough Grading prepared by Earth Systems Southwest and the recent grading is,summarizrd_in the referenced Report of Observations and Testing During lane Grading prepared by.our firm, I d Zh!i)LLIZOM'0N }(Ib3) !'d3S30 OU N3 OYT,' NH4 December 13, 2005 -2 Project No. 544-5951 05-12-11.58 The referenced reports include recommendations pertaining to the r..nnstruction of residential structure foundations. Based upon our review of the referenced reports, it is our opinion that the structural values included in the referenced grading report remain applicable for the design and construction of the proposed residential structure foundations. Because the lot has been previously graded, the remedial ftr'aditig required at this time should be minimal. The building area should be cleared of surface vegetation, scarified and moisture conditioned, prior to precise grading. The exposed surface should be compacted so, that a minimum of 90 percent relative compaction is attained prior to fill placement, Any fill material should be placed in thin lifts at near optimum moisture content and c+)mpacted to at least 90 percent relative compaction. . E Allowable Bearing Pressures: The allowable bearing pressures recommended in the grading report prepared by Sladden Engineering remain applicable. CUPventiunal shallow spread footings should be bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footisgs may be designed utilizing an allowable bearing pressure of 2000 psf. An allowable increase of 300 psf for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be utilized if desired. The maximum allowable bearing pressure should be 3000 psf. The recommended allowable bearing pressures may be increased by one third for wind and seismic loading. The bearing soils are non -expansive and fall within the "v&rY low" expansion category in accurdance with Uniform Building CodeJUBC) classification 'criteria, Pertinent 2001 UBC Seismic Design parameters are summarized,on the attached data sheet If -you have questions regarding this letter or the referencedreports, please contact the undersigned. Respectfully submitted, S>LADIDEN ENGINES G ANO` q� 111 No, C /5389 rn Brett L. Anderson, Exp: 9130/06 principal Engineer SER/pc 4TH OF CNS-\F�C� Copies: 4/Mr. Don Newman c/o Mr. Ken Schmale Sludden Eneineerine a r191 ihi ZOH IS/G.sZ D30 (18J) ; a� ,31a OU N?eOVis w� � 2(Jp1LA1,IPLIPKNIA t5UILIJ NiaLdJVC,JCIJM10 UIG01"IN arnrva�i�a�aav� The California Cucle of Regulations, Title 24,V001 California Building Code) and 1997 Uniform Building Code, Chapter 16 of this code, contain substantial revisions and additions to earthquake engineering design criteria. Concepts contained in the code that will be. relevant to construction of the proposed structures are summarized below, Ground shaking is expected to be the primary hazard most likely,to affect the site, teased upon proximity to significant faults capable of generating large earthquakes. Major fault zones considered to be most likely to create strong ground shaking at the.site are listed below. Fault Zone Approximate Distance From Site Fault Type (1997 1-180 San Andreas 9.8 km : A San Jacinto 26 km --A Based on our field observations and. understanding of local geologic conditinnS, the soil profile type judged applicable to this site is Su, generally described as stiff or dense soil. The site is located within UBC Seismic Zone 4. The following table presents additional coefficients and factors relevant to seismic mitigation for new construction upon adoption of the 1997 code. Near -Source Near -Source Seismic Seismic Seismic Acceleration Velocity Coefficient Coefficient Source Factor, N. #actor, Nv . C. G Son Andreas 1.01 1.0 1.22 0.44 N, 0.64 M San Jacinto 1.0 - 0.44 N. 0.64 N. r TITLE 24 REPORT ,49A.: •_a ,� a Title 24 Report for: The Neuman Residence ` Hideaway - Lot 1OF La Quinta, CA.92253 11-5 VIA WJM30L Project Designer: ' Synergy. Design Inc. 9005 Burton Way, Suite 4 'Los.Angeles,`CA 90048 CITY OF LA QUINTA BUILDING & SAFETY DEPT. (310) 271-8400 APPROVED FOR,CONSTRU TION_ Report Prepared By. pAT_.. Y Brad Stone BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 Job Number Date: 7Dov a 1 11/2/2005 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report: This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft,,LLC-www.enerdysbft.com. EnergyPro 4.0 by EnergySoft Job Number. User Number: 3885 t (�� ,. ..�; ., ... �'y .. ' . V y ' , I Certificate Of Compliance : Residential Fuel Type: (Part 1 of 3) CF -1 R The JVe iman-Residen -e ft2 Area: 1,647 ft2 Avg. U: 0.45 11/2/2005 Project Title JJideaway - I of 1pF I a Quints Zone Name Floor Area Volume Date Project Address Number of Dwelling Units: 1.00 New New New Building Permit # RREE7F AIR # of Thermostat (760) 346-0855 Units Zone Type Type 099 rnnditinnPd R thark .C)s1TIONING Documentation Author Area n/a 0-18 Conditioned Sethack 0.49 Conditioned Setback Telephone Plan Check/Date -Ene ovPro 8 n/a 15 Field Check/Date Complffifce Method ®New ® Climate Zone R-21 R-0.0 -270 -90 Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.69 2.94 -0.25 Space Cooling 59.95 56.76 3.19 Fans 9.04 9.87 -0.84 Domestic Hot Water 3.99 5.70 -1.70 Pumps 0.00 0.00 0.00 Totals ° 75.67 75.27 0.40 Percent better than Standard: 0.5% Building Type: SCJ Single Family ❑ Addition ❑ Multi Family ❑ Existing + Add/Alt Building Front Orientation: (North) 0 deg Fuel Type: Natural Gas Fenestration:. ft2 Area: 1,647 ft2 Avg. U: 0.45 Ratio: 27.2% Avg. SHGC: 0.37 BUILDING ZONE INFORMATION Zone Name Floor Area Volume HVAr #1 1 342 15 970970 ' HVAC #2 1,062 12 744 HVAC #3 2,950 41.300 HVAC #4 698 6.28 Total Conditioned Floor Area: 6,052 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 610 ft2 Slab on Grade Area: 5,354 ft2 Average Ceiling Height: 12.6 ft Number of Dwelling Units: 1.00 New New New Number of Stories: 2 # of Thermostat Vent Units Zone Type Type 099 rnnditinnPd R thark Hgt. _� Area n/a 0-18 Conditioned Sethack 0.49 Conditioned Setback _� 8 h/a n/a 0.12 Conditioned Setback 8 n/a OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U -Fac. Roof Wood 1 342 0 025 Wall Wood 51 0.069 -Awl - Wood 624 0.069 Roof Wood _9 775 0 095 MallWood 485 0"069 Door None 24 0.500 _Wall_- Wood 90 0.069 lafl Wood 430 0.069 Wall Wood 404 0.069 Floor Wood 610 0 024 Roof Wood 698 _0 0251 Mall Wood 322 0"069 oor None 24 0.500 _Wall_ Wood 468 0069 _Wa[l Wood 218 0.069 Cay. Cont. Azm. Tilt YY / NN Status R_38 R-0.0 345 _fi lel ®❑New ®❑New L] R_21 R-0.0 a go R_21 R-0.0 go -qn R-21 R-00 180AI1 R_21 R-0.0 270 90 13_38 R-0.03451 0 ®❑New ::]New ❑New ❑New ❑New R_21 R-0 0 - 090 R-21 R-0 0 -go Q R_21 R-0.0 180 g R_21 R-0.0 270 90® None R-0.0 270 An ® New New New R-38 R-0.0 345 R_21 R-0.0 -o go ® ® New New None R-0.0 0 go R-91 R-0-0 90 90 R_21 R-0.0 180 -90 ❑New ❑New ❑ New R-21 R-0 0 270 gQ R-38 R-0 0 -0 X80 ® ❑ Ex New New R-38 R-0.0 R_21 R-0.0 None -0.0_ -1L-9.0 I ❑ New New New R_21 R-0.0 - o 90 R_21 R-0.0 180 90 ®New ® NPw NewFIH R-21 R-0.0 -270 -90 JA IV Reference Location / Comments EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:3 of 49 Certificate Of CornMiance : Residential (Part 2 of 3) CF -1 R The Neuman Residence 11/2/2005 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 1_-Wnd-0w Left (East) 15.5 0-57 11 _Q_ i`3 X16- X20_ -D_ New Double Metal Clad Tinted ,ZONE #1 2 Window Left (East) 3.0 0.570 116-A 0_53 116-B 90 90 New 00"M91etal Clad Tinted ZONE #1 3 Window Left (East) 21.0 0.370 NFRC 0_29 NFRC 90 90 New P&WAlftasement HPI ZONE #1 4 Window Left (East) 21.0 0.370 NFRC 0_29 NFRC 90 90 New Loewen Casement HP1 ZONE #1 5 Window Left (East) 12.0 0.370 NFRC 0_29 NFRC 90 90 New Loewen Casement HP1 ZONE #1 6 Window Left (East) 12.0 0.370 NFRC 0_29 NFRC 90 90 New Loewen Casement HP1 ZONE #1 7 Window Left (East) 4.0 0.350 NFRC_ 0.36 NFRC 90 90 New Loewen Fixed Glass ZONE #1 8 Window Left (East) 4.0 0.350 NFRC 0.36 NFRC 90 90 New Loewen Fixed Glass ZONE #1 9 -_Window Left (East) 4.0 0.350 NFRC0 36 NFRC 90 90 New Loewen Fixed Glass ZONE #1 1Q Window Rear- (South) 3.1 0.710 116-A0.60 116-B 180 90 New Default Double Metal Tinted ZONE #1 " Window Rear (South) 140.0 0.770 116-A 0_59 116-B 180 90 New fel Double Metal -B ZONE #1 12 Window Front (North) 7.0 0.370 NFRC 0_29 NFRC 0 90 New VBWAnt HP1 ZONE #2 1a Window Front (North) 70.0 0-370 NFRC 0"29 NFRC 0 --K New Loewen Casement HP1 ZONE #2 14 Window Left (East) 4.0 0.350 NFRC 0_36 NFRC 90 90 New Loewen Fixed Glass ZONE #2 15 Window Left i(East) 4.0 0.350 NFRC 0_36 NFRC 90 90 New Loewen Fixed Glass ZONE #2 16 Window Left I(East) 5.1 0.540 116-A 0_55 116-B 90 90 New Double Metal Clad Tinted Fixed ZONE #2 17 Window Left I(East) 5.1 0.540 116-A 0_55 116-8 90 90 New Double Metal Clad Tinted Fixed ZONE #2 18 Window Left 1(East) 120.0 0.350 NFRC 0_20 NFRC 90 90 New Loewen Inswing Terrace Door ZONE #2 19 Window Right (West) 17.0 0.57 116-A 0.53 116-B 270 90 New Mble Metal Clad Tinted ZONE #2 Operable 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shadel Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 4 0.... C......... I n 7C Screen 1 0.76 5.5 3.0 3.0 0.1 3.0 3.0 Screen 1 0.76 5.5 3.0 3.0 0. 3.0 3.0 Screen I 0.76 Screen I 0.76 Screen I 0.76 Screen 1 0.76 Screen I 0.76 Screen I 0.76 Screen I 0.76 Screen 1 0.76 Screen I 0.76 Screen 1 0.76 Screen I 0.76 Screen 1 0.76 Screen I _ 0.76 Screen 1 0.76 10.0 12.0 3.0 0.1 3.0 3.0 Screen I 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference PERIMETER Condition Location/ Status Comments Insulation Condition Location/ R -Val. Location JA IV Reference Status Comments Slab Perimeter 100 None No Insulation 26-A1 New ZONE #1 Slab Perimeter 10 None No Insulation 26 -Al New ZONE #1 Slab Perimeter 42 None No Insulation 26-A1 New ZONE #2 Slab Perimeter 80 None No Insulation 26 -Al New ZONE #2 Slab Perimeter 42 None No Insulation 26-A1 New ZONE #3 Run Initiation Time: 1110210515:49:48 Run Code: 1130975388 EnergyPro 4.0 by Energysoft User Number: 3665 Job Number: Page:4 of 49 J Certificate Of Compliance: Residential (Part 2 of 3) CF -1 R The Neuman Residence 11/2/2005 Project Title i Date FENESTRATION SURFACES True Cond. Location/ # Tvpe Area U -Factor' SHIS Azm. Tilt Stat. Glazing Tvi)e Comments 2-Q Window 21 Window Rightest)�,0_ Right I(West) 120.0 -0-57 116-A -QM �B 0.350 NFRC 0_20 NFRC 97r) -K New Double Metal Clad Tinted ZONE #2 270 90 New DwAftutswing TerraceDoorZONE#2 22 Window Right (West) 4.0 0.350 NFRC 0_36 NFRC 270 90 New YerVven Fixed Glass ZONE #2 23 Window Right i(West) 4.0 0.350 NFRC 0_36 NFRC 270 90 New Loewen Fixed Glass ZONE #2 24 Window Front !(North) 12.0 0.370 NFRC 0_29 NFRC 0 90 New Loewen Casement HP1 ZONE #3 25 Window Front (North) 3.1 0.710 116-A 0_60 116-B 0 90 New Default Double Metal Tinted ZONE #3 26 Window Front orth) 71.6 0.520-115=A 0.53 116-B 0 90 New1561A4 Metal Clad Tinted SwingZONE #3 27 Window Front (North) 105.0 0.520 116-A 0_53 116-B 0 90 New 00961e Metal Clad Tinted SlidinffONE #3 28 Window Rear `(South) 4.0 0.359 NFRC 036 NFRC 180 90 New wren Fixed Glass ZONE #3 2.Q Window Rear - i(South) 4.0 0.350 NFRC 0.36�F C 180 90 New Loewen Fixed Glass ZONE #3 30 Window Rear i(South) 4.0 0.350 NFRC 0_36 NFRC 180 90 New Loewen Fixed Glass ZONE #3 31 Window Rear. '(South) 4.0 0.350 NFRC 0_36 NFRC 180 90 New Loewen Fixed Glass ZONE #3 22 Window Rear '(South) 140.0 0.360 NFRC JLU NFRC 180 _9Q New Loewen Sliding Patio Door ZONE #3 33 Window Rear '(South) 220.0 0.520 116-A 0_53 116-B 180 90 New Double Metal Clad Tinted Slidinc7ONE #3 34 Window Right i(West) 36.0 0.570 116-A 0_53 116-B 270 90 New Nble Metal Clad Tinted ZONE #3 35 Window Right I(West) 3.1 0.710 116-A 0_60 116-B 270 90 New � ouble Metal Tinted ZONE #3 36 Window Right (West) 140.0 0.360 NFRC 0_33 NFRC 270 90 New d-6 Sliding Patio Door ZONE #3 37 Window Front (North) 4.3 0.570 116-A 0_53 116-B 0 90 New Double Metal Clad Tinted ZONE #4 38 Window Left ! (East) 5.2 0.570 11-9 0.53 116-B 90 90 New 8960 etal Clad Tinted ZONE #4 1. Indicate source either from NFRC or Table 116A. 2. Indicate source eitherfrom NFRC or Table 11613Operable INTERIOR AND EXTERIOR SHADING Window Overhang # Exterior Shade Tvoe SHGC Hqt. Wd. Len. Hqt. LEA RExt. 20 Bug Screen ; 0.76 Ti Bug Screen 1 0.76 22 Bug Screen 0.76 23 Bug Screen I 0.76 24 Bug Screen I 0.76 25 Bug Screen 0.76 26 Bug Screen I 0.76 27 Bug Screen 0.76 28 Bug Screen I _ 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen _ 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 10.0 22.0 18.0 0.1 6.0 6.0 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 Left Fin Dist. Len. THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Right Fin Dist. Len. Hgt. PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 131 None No Insulation 26 -Al New ZONE #3 Run Initiation Time: 11/02/05 15:49:48 Run Code: 1130975388 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: Page:5 of 49 { Certificate Of Compliance : Residential APart 2 of 3) CF -1 R The Neuman Residence 11/2/2005 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type i Area LI -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 3.9. Window Left i (Easy 52 0.57 116-A JLU 116-B 90_ __K New Dou61e Metal Clad Tinted ZONE #4 40 Window Left L(East) 32.0 0.350 NFRC 0_20 NFRC 90 90 New QAR%W(tnswing Terrace Door ZONE #4 41 Window Rear I(South) 21.0 0.370 NFRC 0_29 NFRC 180 90 New ffelmen Casement HP1 ZONE #4 42 Window Rear (South) 21.0 0.370 NFRC 0_29 NFRC 180 90 New Loewen Casement HP1 ZONE #4 43 Window. Right (West) 74.6 0.350 NFRC 0_20 NFRC 270 90 New Loewen Outswing Terrace DoorZONE #4 44 Window Right (West) 120.0 0.350 NFRC 0_20 NFRC 270 90 New EWAOutswin Terrace DoorZONE #4 P i 1. Indicate source either from NFRC or Table 11 GA. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 39 Bug Screen t . 0.76 40 Bug Screen I 0.76 41 Bug Screen 0.76 42 Bug Screen l 0.76 43 Bug Screen T0.76 44 Bug Screen 0.76 1 — l THERMAL MASS FOR HIGH MASS DESIGN I Area Thick. Heat Inside Condition. Location/ Type i (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Certificate The Neuman F Project Title 'HVAC SYSTEMS Location HVAC DISTRIB Location HVAC #1 HVAC #2 'HVAC #3 Hydronic Piping Svstem Name WATER HEATING System Name Standard Gas 50 oal or Multi -Family Central Compliance Residential (Part 3 of 3) CF -1 R 11/2/2005 Date Heating Minimum Cooling Minimum Condition Thermostat Type Eff. Type Eff Status Type Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback Heating Coolin Ducted Ducted Ducted Ducted _ Ducted Ducted Pipe ° Pipe Insul. enoth Diameter Thick. Water Heater Type Distribution Duct Duct Condition Ducts Location R -Value Status Tested? Attic 6.0 New Yes Attic 6.0 New Yes Attic 6.0 New Yes Ratedl Tank Energy Standbyl Tank Insul. # in Input Cap. Condition Factor Loss R -Value Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. Small Gas No Pipe Insulation 1 40,000 50 New 0.57 n/a n/a Small Gas No Pipe Insulation 1 40.000 50 New 0.57 n/a n/a Large Gas No Pipe Insulation 1 76.000 75 New 0.72 0.00% 0.0 :r Heating Details Water Pump Hot Water Piping Length (ft) Add 1/2" Control I # HP Type In Plenum Outside Buried Insulation I 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. COMPLIANCE STA' This certificate of compliai Regulations, and the adm The undersigned recogniz and building envelope see Designer or Owner (per Name: Title/Finn: Synergy Desi Address: 9005 Burton I Telephone: Lic. #: ' (signature) Enforcement Agency ' Name: Title/Firm: Address: Telephone: ' CncmvDrn An K, MENT lists the building features and specifications needed to comply with Title 24, Parts 1" and 6 of the California Code of trative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, 3 require installer testing and certification and field verification by an approved HERS rater. siness & Professions Code) Documentation Author Name: Brad Stone Inc. Title/Firm: BREEZE AIR CONDITIONING y, Suite 406 Address: 75-145 ST. CHARLES PLACE k90048 PALM DESERT, CA 92211 Telephone: (760) 346-0855 ' (date) nature) (date) (signature/stamp) (date) Certificate Of Compliance : Residential ' The Neuman RE Project Title ' Special Features at The local enforcement a written justification and agency determines the adequacy of the special Addendum) CF -1 R _ 11/212005 Date Modeling Assumptions icy should pay special attention to the items specified in this checklist. These items require special :umentation, and special verification to be used with the performance approach. The local enforcement quacy of the justification, and may reject a building or design that otherwise compiles based on the 1ification and documentation submitted. I Plan Field 'HERS Required Verification Items In this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider i lan sing CEC approved testing and/or verification methods and must be reported on the CF -4R PField installation certificate. The HVAC System "HVAC #1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. I• The HVAC System "HVA #1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "MAYTAG PSA1 BD / PGC1 RA (5 Ton)" includes credit for a 11.4 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "HVA #2" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVACI #2" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "MAYiTAG PSAIBD / PGCIRA (4 Ton)" includes credit for a 11.9 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "HVACI#3" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC#3" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "MA i AG PSAIBD / PGC1RA (5 Ton)" includes credit for a 11.4 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "HVAC #4" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC #4" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "MAYTAG PSAIBD / PGCIRA (3 Ton)" includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. I • I Mandatory Measures Summary. -Residential (Page 1 of 2) MF-1 R ' NOTE:' Low-rise residential buildings subject to the Standards must.contain these measures regardless of the compliance approach used. More stringent compliance ' requirements from the Certificate of Compliance supercedes the items marked with and,asterisk (') below.. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are - shown elsewh l re in the documents or on this checklist only. ' ENFORCE- DESCRIPTIO Instructions: Check or Initial applicable boxes when completed or check N/A if not ENFORCE- applicable. NIA DESIGNER MENT Building Envelope Measures - ' § 150(a): Minimum R-19 in wood ceiling insulation or equivalent'U-factor in metal frame ceiling. ❑ ❑ ❑ F § 150(b): Loose fill insulation manufacturer's labeled R-Value: ;I ❑ E ❑ § 150(c): Minimum R-1 3 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not ElQ ❑ ' apply to exterior mass walls). § 150(d): Minimum R- 13 raised floor,insulation in framed floors or equivalent U'-factor. ? U El El ' § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ' 1. Masonry land factory-built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ' b. outside air intake with damper and control, flue damper and control ❑ 0 ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑K ❑ § 150(0: Air retarding I rap installed to comply with §151 meets requirements specked in the ACM Residential Manual. ❑K ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑K ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor. r 0 ❑ ❑ permeancel rate no greater than 2.0 per-/inch. § 118: Insulation specked or installed meets insulation installation quality standards. Indicate type and include ER El ElCF-6R. Form: § 116-11: Fenestratioi Products, Exterior Doors, and Infiltration/Exfiltration Controls. - ' 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ 0 ❑ 2. Fenestration products (except field fabricated) have label with certified U-Factor, certified Solar Heat Gain ; ❑ ❑ 0 Coefficientl(SHGC), and infiltration certification. ' 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑ Space Conditioning, Water Heating and Plumbing.System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.: Q ❑K ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑K ❑ ❑ ' § 150(l): Setback thermostat on all applicable heating and/or cooling systems., , ❑ ❑K ❑ § 1500): Water systi pipe end tank insulation and cooling systems line insulation ' 1. Storag I gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation El EK 1:1 having an installed thermal resistance of R-12 or greater. 2: Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R-value. ' 3. The following piping is insulated according to Table 150-AIB or Equation 150-A Insulation Thickness: 1. First 15 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems, and entire ❑ ' ❑K ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. ' 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and , ❑ 0 ❑ indirect hot water tank shall be insulated to Table 150-8 and Equation, 150-A. r : 4. Steam hydronic heating systems or hot water systema > 15 psi, meet requirements of Table 123-A: ❑ ❑ S. Insulatil n must be protected from damage, including that due to sunlight moisture, equipment maintenance, ❑ ❑K ❑ ' and wind. 6. Insulation for chilled water pipingand refrigerant suction piping includes a vapor retardant or is enclosed EK ❑ ❑ entirely ins conditioned space. 1 7. Solar water-heating systemslcollectors are certified by the Solar Rating and Certification Corporation. , ❑X ❑ ❑ EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:9 of 49 ' Mandatolei Measures Summa Residential (Page 2 of 2) MF-1 R ' NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent ' compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. ' I Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE- DESCRIPTION applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and(Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply-air and retum-air ducts and plenums are insulated to a minumum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closure system r that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements ' of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building) cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ X❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and ' support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions) in the cross-sectional area of the ducts. 3. Joints al d seams of duct systems and their components shall not be sealed with cloth back rubber adhesive Elduct ' tapes unless such tape is used in combination with mastic and draw bands. ❑ ® ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity (ventilating systems serving conditioned space have either automatic or readily accessible, manually operating❑ X❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ © ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause, degradation of the material. ' ® ❑ ❑ 7. Flexible' ducts cannot have porous inner cores. _ § 114: Pool and Spa Heating Systems and Equipment 1. A the lal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter,and heater for future solar heating. ® ❑ ❑ ' b. Cover for outdoor pools or outdoor spas. X❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. X❑ ❑ ❑ § 115: Gas fired fan-,type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously. ❑ ® ❑ ' burning pilot light. (Exception: Non-electrical cooking appliances with pilot < 150 Btu/hr) § 118 (1): Cool Roof material meets specked criteria ❑X ❑ ❑ Lighting Measures ' § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric aid have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,❑ X❑ ❑ luminaire has factory installed HID ballast. ' § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 136(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided(that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in.bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑X❑ ❑ OR are controlled by an occupant sensor(s) ceritfied to comply with Section 119(d). ' § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,ggarages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑X ❑ controlled by an occupant sensor that complies with Section.119(d) that does not turn on automatically or have an alwayson optEl 0 1:1ion. § 150(k)5: luminaires that are recessed Into insulated ceilings are approved for zero clearance insulation cover (IC) and are ' certified (o ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(66: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ X❑ ❑. same lot1shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). ' § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.. r Q ❑ ❑. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131; and 146. § 150(k)8: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more X❑ ❑ ❑. dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section ' 119(d). EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page: 10 of 49 Residential Kitchen Lighting Worksheet WS -5R The Neuman Residence 11/2/2005 Project Title I Date At least 50% of the total rated wattage of permanently Installed luminaires In kitchens must be In luminaires that are high efficacy luminaires as defined In Table 150- (..Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be Installed In kitchens. High Efficacy,. Luminaire Type High Efficacy? Watts : Quantity Watts Other Watts Iris P7421CAT UT Yes X No, 42.0 x 14 = 588 or 4" REX 204LC-LV744 I Yes X No 50.0 x 3 -_ 150 or WAC LP 808 I` Yes X No 50.0 x 2 = 100 or Kichler 21 W Fluorescent 1002X Yes X No 21.0 x 5 = 105 or I Yes No I x = or I Yes No x - or I Yes No x = or I Yes . No I x - or Yes No' x . or I - Yes No x - or Yes No X - or I Yes No x = or I Yes _ No x _ or Yes No I x = or I Yes No x - or I Yes No x = or I Yes a No x = or Yes No x _ or Yes No x = or I Yes No x = or . r Total A:,,943 B: 0 ' COMPLIES IF AZ B YES R NO ❑ EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page: 11 of 49 LVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME I DATE The Neuman Residence 11/2/2005 SYSTEM NAME I FLOOR AREA HVAC In 1,342 Number of Systems COIL HTG. PEAK 1 Heating System Latent Output per System I 86,000 Total Output (Btuh) I 86,000 Output (Btuh/sgft) ( 64.1 Cooling System 2,253 Output per System I 56,000 Total Output (Btuh)I 56,000 Total Output (Tons) I 4.7 Total Output (Btuh/sgft) 41.7 Total Output (sgft/Ton) 287.6 Air System CFM per System I 2,000 Airflow (cfm) I 2,000 Airflow (cfm/sgft) I 1.49 r428.6 Airflow (cfm/Ton) I Outside Air (%) I 5.0 Outside Air (cfm/sqt) 0.08 Note: values above gl, HEATING SYSTEM 26.0 OF 0 Outs . 101 cfm 69.3 OF at ARI conditions YCHROMETRICS , 67.2 OF SYSTEM Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts i TOTAL SYSTEM LOAD , COIL COOLING PEAK COIL HTG. PEAK CFM I SensIbIP1 Latent I I CFM I Sensible 1,084 21,193 3,546 530 20,83 0 106.9 OF Supply Fan 1,960 1,395 0 0 10 4,077 2,253 101 4,643 0 0 1,960 1,395 29,119017775 799 282763 HVAC EQUIPMENT SELECTION MAYTAG PSAIBD / PGCIRA (5 Ton) 47,081 0 86,000 Total Adjusted System Output 47,08 0 86,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 107.6 OF Heating Coil res at Time of Heatinq Peak) 107.6 OF Supply Air Ducts 106.9 OF Supply Fan 2000 cfm ROOMS 70.0 OF 1% Return Air Ducts ',I DOLING SYSTEM IPSYCH ROM ETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6°F I 74.8/61.2°F 52.7/51.7°F 52.7/51.7°F Supply Air Ducts Outside Airy 101 cfm Cooling Coil Supply Fan 53.6 / 52.0 OF 2000 cfm 49.1% R.H. IROOM7S 72.9/60.1°F 72.0/59.8°F h Return Air Ducts 11 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page: 12 of 49 J HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAMEI DATE The Neuman Residence 11/2/2005 SYSTEM NAME I FLOOR AREA 'HVAC 4;2 1,062 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System I 58,000 Total Output (Btuh) I 58,000 Output (Btuh/sgft) I 54.6 Cooling System Output per System I' 48,000 Total Output (Btuh) I 48,000 Total Output (Tons) I 4.0 Total Output (Btuh/sgft) 45.2 Total Output (sgft/Ton) 265.5 Air System CFM per System I 1,600 Airflow(cfm)• I 1,600 Airflow (cfm/sgft) I 1.51 Airflow (cfm/Ton) I 400.0 Outside Air (%) I 5.0 Outside Air (cfm/sgft) 0.08 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts COIL COOLING PEAK COIL HTG. PEAK CFM ISensibl,1 Latent CFM I Sensible ' EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 1,049 21,540 2,973 �06 19,588 Supply Air Ducts 0 1,992 1,312 0. o 80 3,205 1,922 80 3,664 0 x K' 156 0 1,992 1,312 TOTAL SYSTEM LOAD 1 28,7301 4 895 25 876 HVAC EQUIPMENT SELECTION MAYTAG PSA1 BD / PGC1 RA (4 Ton) 40,054 0 58,000 Total Adjusted System Output 40,054 0 58,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Note: values above given at ARI conditions ' EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF I 67.10F 101.10F 101.10F Supply Air Ducts Outside Air x K' 156 80 cfm 100.4 OF Heating Coil Supply Fan ' 1600 cfm ROOMS 70.0 OF 69.2 OF Return Air Ducts 4 I DOLING SYSTEM IPSYCHROMETRICS Airstream Temperatures at Time of Coolin Peak 111.0 / 77.6 OF I 75.1 / 60.8 OF- 51.5 / 50.4 OF 51.5/50 A OF Supply Air Ducts Cog) ' out Air . 80.cfm Cooling Coil Supply Fan 52.7 / 50.9 OF 1600 cfm ROOMS 47.0% R.H. 72.0/59.2 OF 73.2/59.60F Return Air Ducts t EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page: 13 of 49 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME I DATE The Neuman Residence 11/2/2005 SYSTEM NAME I FLOOR AREA HVAC #3 2,950 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 2 Heating System Output per System I 86,000 Total Output (Btuh) I 172,000 Output (Btuh/sgft) I 58.3 Cooling System Output per System I 56,000 Total Output (Btuh) I 112,000 Total Output (Tons)( 9.3 Total Output (Btuh/sqft) 38.0 Total Output (sgft/Ton) 316.1 Air System CFM per System I 2,000 Airflow (cfm) , I 4,000 Airflow (cfm/sqft) I 1.36 Airflow (cfm/Ton) I 428.6 Outside Air (%) I 5.5 Outside Air (cfm/sgft) 0.08 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts COIL COOLING PEAK 1 COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 2,486 47,681 6,836 1,062 41,492 ROOMS 0 70.0 of Return Air Ducts 4,410 2,778 0 0 22 8,934 4,897 221 10,206 0 0 4,410 2,778 TOTAL SYSTEM LOAD 65,435 11,734 57 256 HVAC EQUIPMENT SELECTION MAYTAG PSA1 BD / PGC1 RA (5 Ton) 94,480 0 172,000 Total Adjusted System Output94,4801 � 172,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Note: values above given at ARI conditions I L - (EATING SYSTEM PSYCHROMETRICS (Airstream Te 26.0 of I 66.9 of = 107.4 of Outside Air . 221 cfm 69.3 of I 111.0 / 77.6 of Outside �Air 221 cfm 73.0/60.2 of Heating Coil 107.4 of vNi Supply Air Ducts Supply Fan 106.7 of 4000 cfm ROOMS 70.0 of Return Air Ducts I 75.1/61.4OF M 52.9/51.9OF Cooling Coil Supply Fan 4000 cfm 52.9 / 51.9 of -41 Supply Air Ducts 54.0 / 52.3 of 49.4% R.H. ROOMS 72.0 / 59.9 of h Return Air Ducts EnergyPro 4.0 by Energysoft User Number: 3665 Job Number. Page: 14 of 49 � 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAMEDATE The NIeuman Residence 11/2/2005 SYSTEM NAME I FLOOR AREA HVAC #4 698 NEERING CHECKS Number of Systems 1 Heating System Output per System ( 43,000 Total Output (Btuh) I 43,000 Output (Btuh/sgft) I 61.6 Cooling System Output per System 36,000 Total Output (Btuh) I 36,000 Total Output (Tons) I 3.0 Total Output (Btuh/sgft) 51.6 Total Output (sgft/T ion) 232.7 Air System CFM per System I 1,200 Airflow (cfm) I 1,200 Airflow (cfm/sgft) I 1.72 Airflow (cfm/Ton) I 400.0 Outside Air (%) I 4.4 Outside Air (cfm/sgft) 0.07 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 22,065 3 50 775061 MAYTAG PSAIBD / PGC 1RA (3 Ton) 29,962 0 43,000 Total Adjusted System Output 29 962 0 43,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF I 67.4 OF 101.10F 101.10F f izi Supply Air Ducts Outside Air 4; 52 cfm 100.4 OF Heating Coil Supply Fan 1200 cfm ROOMS 70.0 OF 69.3 OFI Return Air Ducts DOLING SYSTEM IPSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6°F 74.9/60.6°F 51.4/50.3°F 51.4/50.3 OF r w4 Supply Air Ducts Outside Air 52 cfm Cooling Coil Supply Fan 52.6/50.8 °F 1200 cfm 46.8% R.H. ROOMS 73.2/59.6 °F 72.0 / 59.1 OF Return Air Ducts I I EnergyPro 4.0 by EriergySoft User Number: 3665 Job Number. Page:15 of 49 1 ROOM LOAD SUMMARY PROJECT NAMEI DATE ' The Neuman Residence y. 11/2/2005 SYSTEM NAME FLOOR AREA HVAC #1 1,342 ROOM LOAD SUMMARY i ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME I ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ' Master Suite / Laundry ZONE#1 I 1 1,084 21,193 3,546 .1,084 21,193 3,546 530 20,831 1 I s i r , 530 20,831 ,. PAGE TOTAL 1 1,084 21,193 3,546 ' TOTAL 1 1,084 421,193 -3,54611 530 20,831 EnergyPro By Energysoft User Number: User Page:16 of 49 Job Number. - '' ROOM LOAD SUMMARY ' PROJECT NAME I The r' Neuman Residence, ' DATE 11/2/2005 SYSTEM NAME I HVAC #2 FLOOR AREA 1,062 ' ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #2 I Office / Guest Bedroom 1 1,049 '21,540 2,973 1,049 21,540 2,973 606 19,588 1 PAGE TOTAL .1,049 21,540 TOTAL 1 1,049 21,540 2,9731. 606 19,588 2,973 6,061 19,588 EnergyPro By EnergySoft User Number. User Job Number. Page: 17 of 49 f 1 ROOM LOAD SUMMARY _ PROJECT NAME DATE ' The Neuman Residence 11/2/2005 SYSTEM NAME I FLOOR AREA HVAC #3 2,950 1 ROOM LOAD SUMMARY. ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult: CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE I Living Area . ZONE #3 ' 1 2,486 47,681 6,836 2,486 47,681 6,836 1,062 41,492 1 o - r f 1,0621 Al A09 1 1 r PAGE TOTAL 1 2,4e6 47s81 6,836 * < TOTAL 1 2,486 47,681T -7-6,8736F1,06211 41,492 1 Page: 18 of 49 EnergyPro By EnergySof - User Number: User Job Number. ROOM LOAD SUMMARY ' PROJECT NAME DATE The Neuman Residence 11/2/2005 SYSTEM NAME I I FLOOR AREA HVAC #4 698 ' ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ' ZONE NAME I ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE + Upstairs Guest ZONE #4, I 1 817 16,845 2,228 817 16,845 2,228 412 13,311 .I t 412 13,311 PAGE TOTAL 817 16,845 2,228 TOTAL 817 16,845 2,228 412 13,311 Page: 19 of 49 EnergyPro By EnergySoft User Number: User Job Number. ROOM HEATING PEAK LOADS r ' Project Title- Date The Neuman Residence 11/2/2005 Room Information Design Conditions ' Room Name Master Suite/ Time of Peak Jan 12•am Floor Area jai Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature, 70°t ' Conduction Area LI -Value AT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 14'896 Infiltration: r '1.001x 1.osa x 1342 x 11.90 X0.476 / 60� x 0 = 5 93a ' `schedule Air Sensible Area Calling Height ACH &T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 21,128 ' EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:20 of 49 1342.0 'X X x X X X x X X X X X X X x X X X X X X x X X X x X X X X x X X X X x x x x 0.0250 X x X X X X x x X X X x X x X X X x x x x x x x x X X X x. X x x x x x X x X X 44 = = = = = = _ = = = = = = _ _ _ = _ = = = 1,476 51.0 • 0.0690 44 155 623.5 0.0690 44 1,893 15.5 0.5700 44 389 3.0 0.5700 44 75 21.0 0.3700 44 342 21.0 0.3700 44 342 12.0 0.3700 44 195 12.0 0,3700 44 195 4.0 0.3500 62 4.0 0.3500 44 F;9 4.0 0.3500 44 62 186.9 0.0690 44 567 3:1 0.7100 44= 97 0 .0.7700 44=4743 228.0 0.0690 44 692 perimeter= 100.0' perimeter= 10.5 01300 44 3-212 0.7300 44=337 + Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 14'896 Infiltration: r '1.001x 1.osa x 1342 x 11.90 X0.476 / 60� x 0 = 5 93a ' `schedule Air Sensible Area Calling Height ACH &T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 21,128 ' EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:20 of 49 ROOM HEATING PEAK LOADS Project Title Date The Neuman Residence 11/2/2005 Room Information 'Design Conditions Room Name Office / Guest Time of Peak Jan 12 am Floor Area BedIVbT Outdoor Dry Bulb Temperature 26 of Indoor Dry Bulb Temperature 700E n Conduction Area U -Value AT OF Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 14 892 Infiltration: r too x 1.osa X 1,062 x I X 0.472 / 60] x ehedule Air Sensible . Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 19,865 EnergyPro 4.0 by Energysoft User Number: 3665 Job Number. Page:21 of 49 1062.0 x X X X x X x X X X X x X X X X X x X X X X x X X X X x x X x X x x X X X X X 0.0250 x X X x X x X X X X X X X X X X X x X x X X x x x x X" x x X x X x X X x x x X 44 = = = = = = = = = = = = = = = = = = _ = = = - _ = = 1,168 ' ` ; 249.0 0.0690 44 756 7.0 0.3700 44 114 70.0 0.3700 44 1,140 369.8 0.0690 44 1,123 4.0 0.3500 44 62 4.0 0.3500 44 62 5.1 0.5400 44 121 5.1 0,5400., 44 121 120.0 0.3500 1,848 30.0 0.0690 44=91 315.0 0.0690 44 956 17.0 0.5700 44 426 17.0 0.5700 44= 426 120.0 0.3500. 44 1,848 26.0 0.5000 44 572 44 62 4.0 0.3500 44=62 perimeter = 42.5 0.7300 44 1,365 perimeter = 80.0 0.7300 44 2,570 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 14 892 Infiltration: r too x 1.osa X 1,062 x I X 0.472 / 60] x ehedule Air Sensible . Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 19,865 EnergyPro 4.0 by Energysoft User Number: 3665 Job Number. Page:21 of 49 I ROOM HEATING PEAK LOADS Project Title Date The Neuman Residence 111/2/2005 ' Room Information Design Conditions Room Name Living Area Time of Peak Jan 12 am Floor Area 2,950 Outdoor Dry. Bulb Temperature 26 of Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 28 447 Infiltration: r 1.00 X 1.064 X 2 950 X 14.00 X 0.405 / 6 ] X ® _ 13.045 `schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 44,563 EnergyPn 4.0 by EnargySaft User Number: 3665 Job Number. f age:22 e f4g 2,775.0 X X X x X X X X X X X X X X x X X X X X X X X X X X X X X XX x X X X X X x X X 0.0250 X X x x X x X X X X X X X X X X X X X X x X X X X X X x X x X X X X x x X X 44 = = = = = = = = = = = = = = = = = = = = 3,052 485.3 0.0690 44 1,473 12.0 0.3700 44 195 3.1 0.7100 44 97 71.6 0.5200 44 1,638 105.0 0.5200 44 2,402 24.0 0.5000 44 528 90.0 0.0690 44 273 430.0 0,0690 44 1,305 4.0 0.3500 62 4.0 0.3500 44 R9 4.0 0.3500 44 62 4.0 0.3500 44 62 140.0 0.3600 i44= 2,218 220.0 0.5200 44=5034 403.9 0.0690 44 1,226 M700 44 903 3.1 0.7100 44=97 140.0 0.3600 44 2,218 erimeter = 41.5 0.7300 44 1,333 perimeter=131 0,7300. 44 4,208 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 28 447 Infiltration: r 1.00 X 1.064 X 2 950 X 14.00 X 0.405 / 6 ] X ® _ 13.045 `schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 44,563 EnergyPn 4.0 by EnargySaft User Number: 3665 Job Number. f age:22 e f4g ' ROOM HEATING PEAK LOADS ' ■ Project Title The Neuman Residence 88.0 Date 111/2/2005 Room Information Desi n Conditions Room Name Upstairs Guest Time of Peak Jan 12 am Floor Area E,98 Outdoor Dry Bulb.Temperature 26OF Indoor Dry Bulb Temperature 70 OF 698.0 Conduction Area U -Value AT OF Btu/hr 1 ' Items shown with an asterisk (•r) denote conduction through an interior surface to another room. Page Total: 10 225 Infiltration: 1.00 1 x 1.064 x 698 x 9.00 x 0.630 / 60] x 0 = 3 087 ' chedule AIr Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 12,676 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page: 23 of 49 88.0 X X X X X X X X. X x X X X X X X X X X x X X x X X x X X X X X X X X X X X x X 0.0340 X X X X X X X X X X X X X X X X X X X x X X x X X x X X X X X X X X X X X x X 0 = = = = = = = = = = = = = = = = = 0 610.0 0.0240 44 644 698.0 0.0250 44 768 321.7 0.0690 44 977 4.3 0.5700 44 108 24.0 0.5000 44 528 467.6 0.0690 44 1,420 5.2 0.5700 44 130 5.2 0,5700 44 130 32.0 0.3500 493 218.0 0.0690 44 662 21.0 0.3700 44 342 21.0 0.3700 44 342 225.4 0.0690 44= 684 74.6 0.3500 44 1-149 120.0 0.3500 44 1,848 9 I i ' Items shown with an asterisk (•r) denote conduction through an interior surface to another room. Page Total: 10 225 Infiltration: 1.00 1 x 1.064 x 698 x 9.00 x 0.630 / 60] x 0 = 3 087 ' chedule AIr Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 12,676 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page: 23 of 49 M RESIDENTIAL ROOM COOLING LOAD SUMMARY ' Project Title Date The Neuman Residence 11/2/2005 Room Information Design Conditions ' Room Name: Master Suite / Laundry Outdoor Dry Bulb Temperature: 720F Floor Area:. 1,342 sf Outdoor Web Bulb Temperature: 1120F Indoor Dry Bulb Temperature: .72 OF Outdoor Daily Range: 340F Orientation Area x • X X X X X X X X X X X U -Factor X X X X X X x X X X X X CLTD 1 = = = = = = Btu/hr X x X x x x x X X x North r 1,342.0 0.0250 56.0 1,879 North 7 51.0 0.0690 23.0 81 East 623.5 0.0690 33.0 1,420 South 186.9 0.0690 26.0 335 est 228.0 0.0690 33.0 519 12.0 35.4 425 East 0.0 18.2 12.0 35.4 425 East 0.0 20.4 4.0 41.7 167 East 0.0 20.4 4.0 41.7 167 East 0.0 20.4 4.0 41.7 167 South 0.0 36.5 3.1 36.6 113 Items shown with an asterisk (') denote conduction through an interior surfacerto another room. Page Total 4 234 ' 1. Cooling Load Temperature Difference (CLTD) t Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr CsmntWdw Z CsmntWdw Y CsmntWdw X CsmntWdw CsmntWdw V CsmntWdw U FxdWdw LL FxdWdw MM FxdWdw N FxdWdw ' Page Total 3,8041 Internal Gain Btu/hr Occupants [::]4 X Occupants X 230 Btuh/oCC. = 920 ' E ui ment. X Dwelling Units X 1,6001 Watts/sgft = 1.600 Infiltration: Lo64 X 1.49 X 85.03 x &T = 5 395 ' Air Sensible CFM ELA DT ' TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,193 Latent Gain_ . Btu/hr Occu ants - X Occupants X 200 Btuh/oCC. 800 Infiltration: 4 771 X 1.49 X 85.03 x 0.00454 _ 2 746 ' Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,546 ' EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page: 24 of 49 East 0.0 X x X X x X X x X x 31.1 + + + + + + + + + + 15.5 X x X x x x x X X x 62.5 = = = = = = = = = 969 East 0.0x 31.1+ 3.0X 62.5= 188 East 8.8 18.2 12.2 35.4 592 East 8.8 18.2 12.2 35.4 592 East 0.0 18.2 12.0 35.4 425 East 0.0 18.2 12.0 35.4 425 East 0.0 20.4 4.0 41.7 167 East 0.0 20.4 4.0 41.7 167 East 0.0 20.4 4.0 41.7 167 South 0.0 36.5 3.1 36.6 113 ' Page Total 3,8041 Internal Gain Btu/hr Occupants [::]4 X Occupants X 230 Btuh/oCC. = 920 ' E ui ment. X Dwelling Units X 1,6001 Watts/sgft = 1.600 Infiltration: Lo64 X 1.49 X 85.03 x &T = 5 395 ' Air Sensible CFM ELA DT ' TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,193 Latent Gain_ . Btu/hr Occu ants - X Occupants X 200 Btuh/oCC. 800 Infiltration: 4 771 X 1.49 X 85.03 x 0.00454 _ 2 746 ' Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,546 ' EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page: 24 of 49 RESIDENTIAL ROOM COOLING LOAD SUMMARY F ctTitle Date he Neuman Residence 11/2/2005 Room information Desi n Conditions Room Name: Office / Guest Bedroom Outdoor Dry Bulb Temperature: 72°F Floor Area: 1,062 sf Outdoor Web Bulb Temperature: 1120F Indoor Dry Bulb Temperature: 72 'F Outdoor Daily Range: 340F Opaque Surfaces R-38 Roof R.38.2x14.16 R-21 Wall .21.2x6.16 R-21 Wall .21.2x6.16 R-21 Wall .21.2x6.16 R-21 Wall .21.2x6.16 Solid Wood Door. Orientation Area U -Factor CLTD 1 Btu/hr 1,062.0 X 249.0 X 369.8 X 30.0 X 315.0 X 26.0 X 0.5000 X 0.0 X 70.0 X 1,271 X 0.0 X 4.0 X Items shown with an asterisk (') denote conduction through an interior surface -o another room. 1. Cooling Load Temperature Difference (CLTD) 0.0250 X X X X X X X X X X X X 56.0 = = = = = = 0.0690 23.0 0.0690 33.0 0.0690 26.0 0.0690 33.0 0.5000 33.0 0.0 18.2 70.0 18.2 1,271 East 0.0 20.4 4.0 41.7 167 East Page Total Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr CsmntWdw A CsmntWdw B FxdWdw HH FxdWdw II FxdWdw BB FxdWdw AA FrenchDr 16 CsmntWdw C CsmntWdw D FrenchDr 2 Page Total 1 10,4931 Internal Gain Btu/hr Occupants 4 X Occupants X 230 Btuh/occ. = 920 E ui ment X Dwelling Units X 1,6001 Watts/sgft = 1 1,6001 Infiltration: 1.064 x 1.49 x 67.29 X 4 = 4 269 Air Sensible CFM ELA &T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,5401 Latent Gain Btu/hr Occupants ®. X Occupants X 1 200 Btuh/occ. = 800 Infiltration: 4 771 x 1.49 x 67.29 x 0.00454 = 2.1731 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,973 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:25 of 49 North 0.0 x X X X x x X x x x14.4 X 18.2 + + + + + + + + + + + 7.0 X X X x x X x x X x X 18.2 = = = = = = = = = = 127 North 0.0 18.2 70.0 18.2 1,271 East 0.0 20.4 4.0 41.7 167 East 0.0 20.4 4.0 41.7 167 East 0.0 31.2 5.1 63.9 326 East 0.0 31.2 5.1 63.9 326 East 27.6 14.4 92.4 26.3 2,828 est 0.0 31.1 17.0 62.5 1,063 est 0.0 31.1 17.0 62.5 1,063 est 0.0 120.0 26.3 3155 Page Total 1 10,4931 Internal Gain Btu/hr Occupants 4 X Occupants X 230 Btuh/occ. = 920 E ui ment X Dwelling Units X 1,6001 Watts/sgft = 1 1,6001 Infiltration: 1.064 x 1.49 x 67.29 X 4 = 4 269 Air Sensible CFM ELA &T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,5401 Latent Gain Btu/hr Occupants ®. X Occupants X 1 200 Btuh/occ. = 800 Infiltration: 4 771 x 1.49 x 67.29 x 0.00454 = 2.1731 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,973 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:25 of 49 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Neuman Residence J 11/2/2005 Room Information Design Conditions Room Name: Office / Guest Bedroom Outdoor Dry Bulb Temperature: 720F Floor Area: 1,062 sf Outdoor Web Bulb Temperature: 1120F Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 340F Opaque Surfaces U -Factor CLTD 1 x x x X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to another room. - 1. Cooling Load Temperature Difference (CLTD) Shaded Fenestration Orientation Area GLF Btu/hr Unshaded - Area GLF Btu/hr 0.0x X X X x X X X x X 20.4+ + + + + +. + + + + 4.0x X X X X X X X X X 41.7= = = = 167 0.0x 20.4+ 4.0X 41.7= 167 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21540 Latent Gain Btu/hr Occu ants ® X Occupants X 200 Btuh/occ. = 800 Infiltration: 4,77 X 1.49 X 67.29 X 0.00454 = - 2173 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM - 2,973 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:26 of 49 Page Total 1 334 Internal Gain 1. .. Btu/hr Occu ants]E 4 X Occupants X 230 Btuh/occ. = 920 E ui ment X Dwelling welli g Units X 1,6001 Watts/sgft = 1,600 Infiltration: 1.064 X 1.49 X 67.29 X = 4269 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21540 Latent Gain Btu/hr Occu ants ® X Occupants X 200 Btuh/occ. = 800 Infiltration: 4,77 X 1.49 X 67.29 X 0.00454 = - 2173 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM - 2,973 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number. Page:26 of 49 a 1 T RESIDENTIAL ROOM COOLING LOAD SUMMARY. Project Title Date The Neuman Residence 111/2/2005 ' Room Information Desicin Conditions Room Name: Living Area Outdoor Dry Bulb Temperature: 720F Floor Area: 2,950.sf Outdoor Web Bulb Temperature: 112OF Indoor Dry Bulb Temperature: 72 OF Outdoor Daily Range: 340F Opaque Surfaces R-38 Roof R.381A4.16 R-21 Wall W.21.2x6.16 Solid Wood Door R-21 Wall .21.24.16 R-21 Wall .21.24.16 R-21 Wall .21.24.16 Orientation ' Area . 2,775.0 x 485.3 x 24.0 x 90.0 x 430.0 x 403.9 x North X 18.2 X 18.2 X 0.0 X 3.1 X North x Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration CsmntWdw E FxdWdw F FrenchDr 3 Sld GlsDr 4 FxdWdw Q FxdWdw P FxdWdw O . FxdWdw N Sld GIsDr 10 SId GlsDr 9 U -Factor 0.0250 0.0690 0.5000 0.0690 0.0690 0.0690 CLTD 1 Btu/hr X oo.0 = x 23.0 = x 23.0 = x 33.0 = x 26.0 = x 33.0 X X X X X X Page Total Orientation Btu/hr Shaded Area, X X X X X X x X x x30:1 GLF + + + + + + + + + + Unshaded Area X X X x x X x X X xX+X Page GLF _ _ _ = = = North 0.0 18.2 12.0 18.2 North 0.0 36.5 3.1 36.5'= North 0.0 30.1 71.6 30. North 0.0 30.1 105.0 30. South 0.0 20.4 4.0 20.4 South 0.0 20.4 4.0 20.4 South 0.0 20.4 4.0 20.4 South 0.0 20.4 4.0 20.4 South 0.0 19.4 140.0 19. South 220.0 [�� Total Btu/hr Internal Gain Btu/hr Occupants 4 X Occupants X 230 Btuh/occ. E ui ment X Dwelling Units X 1,600l 1,6o0Watts/sgft =, 1,6001 Infiltration: 1.064 x tas X 186 91 X ' Air Sensible CFM ELA &T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 47,681 Latent Gain Btu/hr Occupants ® X Occupants X. 2001 Btuh/occ. = 800 ' Infiltration: 477 X 1.49 X 186.91 X 0.00454 = 6 036 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,836 EnergyPro 4.0 by EnergySoft User Number: 3665 Job Number: Page:27 of 49 RESIDENTIAL ROOM COOLING LOAD SUMMARY ' Project Title 4 Date The•Neuman Residence 11/2/2005 Room Information Design Conditions Room Name: Living Arca Outdoor Dry Bulb Temperature:. 720F Floor�Area: 2,950 sf Outdoor Web Bulb Temperature: 1120F Indoor Dry Bulb Temperature: 72:F Outdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr Items shown with an asterisk (•) denote conduction through'an interior surface !o another room. Page Total 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr est 4 x x x x x x x X x x xx x X X X X X x x x x X x x x x x x x x x x x x + + + + + + + + + + + — = = = = = = = = _ = x X X X x x x X X X X 62.5 = = = = = = — = — = - 2,25 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM est 0.0 36.5 3.1 72.1 223 est 0.0 19.4 140.0 39.0 5,46 5 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,836 ' ` Ener Pro 4.0 b Ener Soft User Number: 3665 Job Number. fY Y �Y Pa e:28 of 49 � Items shown with an asterisk (•) denote conduction through'an interior surface !o another room. Page Total 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr est 4 0.0 X X X X X x x x x X x 31.1 + + + + + + + + + + + 36.0 x X X X x x x X X X X 62.5 = = = = = = — = — = - 2,25 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM est 0.0 36.5 3.1 72.1 223 est 0.0 19.4 140.0 39.0 5,46 5 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,836 ' ` Ener Pro 4.0 b Ener Soft User Number: 3665 Job Number. fY Y �Y Pa e:28 of 49 � Page Total 7 Sao Internal Gain Btu/hr ' Occupants 4 x Occupants X : 230 Btuh/oCC. = B . 920 E ui ment x Dwelling Units x 1,60 Watts/sgft = 1,6001 Infiltration: Cosa X 4 1 49 X 186.91 X = 11 859 ,- Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 47,681 Latent Gain Btu/hr , � Occu ants I 41 X Occupants X 200 BtUh/OCC. _ 800 Infiltration: 4 77 x 1.49 x 186.91 x 0.00454 ' = 6 036 ' Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,836 ' Ener Pro 4.0 b Ener Soft User Number: 3665 Job Number. fY Y �Y Pa e:28 of 49 � RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Neuman Residence 11/2/2005 Room Information Desi n Conditions Room Name: Upstairs Guest Outdoor Dry Bulb Temperature: 720F Floor Area: 698 sf Outdoor Web Bulb Temperature: 1120F Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 340F Opaque 5urraces 'R-30 Floor No CraWISDace 1 Solid Wood Door R-21 Wall W.21.2x6.16 R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation . Area U -Factor 88.0 X 610.0 X 698.0 X 321.7 X 24.0 X 467.6 X 218.0 x 225.4 x 26.0 X 33.0 X y X 18.2 X Items shown with an asterisk (•) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Area GLF Fenestration Orientation North East . ` East East South South est est 0.0340 0.0240 0.0250 0.0690 0.5000 0.0690 0.0690 0.0690 X X X X X X x x X X X X CLTD 1 = = = = = = = = = Btu/hr 0.0 0 19.0 278 56.0 977 23.0 511 23.0 .276 33.0 1,065 26.0 391 33.0 '513 18.2 21.0 18.2 0.0 18.2 21.0 18.2 0.0x Page Total a' 011 i Unshaded Area GLF Btu/hr 0.0X x x X X X X 31.1+. + + + + + + 4.3x X X x X X X 31. 0.0x 31.1+ 5.2X 62.5 0.0x 31.1+ 5.2x 62.5 0.0x 14.4+ 32.0X 26.3 0.0 18.2 21.0 18.2 0.0 18.2 21.0 18.2 0.0x 14:4+ 74.6x 26.3 0.0 14.4 120.0 26.3 Page Total Internal Gain Btu/hr Occu ants 4 x Occupants X 230 Btuh/occ. = 920 E ui ment. X Dwelling Units x 1 .'6001 Watts/sqft = 1 600 Infiltration: 1.064 x 1.49 x 44.23 x = 2 806 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,8451 Latent Gain Btu/hr Occu ants F 41 X' Occupants -X 2001 Btuh/occ. = 800 Infiltration: 4 771 x 1.49 x 44.23 x 0.00454 = j,4281 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,228 EnergyPro 4.0 by Energysoft User Number: 3665 Job Number. Page:29 of 49 -71