05-0645 (SFD)414 4114M
P.O. BOX 1504. VOICE (760) 777=7012
78-495 CALLE TAMPICO FAX. (760) 777-7011
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 6/29/05
Application Number: 0�5-00000-64"5 : Owner:
Property Address: 80235 VrA �IIRASOL M/M PALLEY
APN: 772-430-007 - PO BOX 356
Application description: DWELLING - SINGLE FAMILY DETAQ+ED 6 LA QUINTA, . CA 92253
Property Zoning: LOW DENSITY RESIDENTIAL D <
Application valuation: 503602
3
1uL Q 1 2��5 Contractor:
Applicant: Architect or. Engi r: JACOBS HOMES INC, PETER
CITY OF UINTA P.O. BOX 692
FINANCEDEPT• LA QUINTA, - CA 92247
(760)777-9921 '
Lic. No -:'799449
LICENSED CONTRACTOR'S DECLARATION - WORKER'S COMPENSATION DECLARATION-
I hereby. affirm under penalty of perjury that I am -license under provisions of Chapter 9 (commencing with - I hereby affirm under penalty of .perjury one of the following declarations: - - -
Section 7000) of Division 3 of the.Business an nals Code, and my License is in full force and -effect. - I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
• License Clas . B License No.: 799449- for by Section 3700 of the Labor Code, for the performance of the work for which this permit is `
issued '
01
I have and will maintain workers' compensation insurance as required by Section 3700 of the Labor
• • - � Code, for the performance of.the work for which this permit is issued. My workers' compensation_
OWNER -BUILDER DECLARATION - • - insurance carrier and policy number are: • -
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier HRH INSUR - Policy Number 176983305 - -
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to - _ 'I certify that, in the performance of the work for which this permit is issued, I shall not employ any
m -
• construct, alter, improve, deolish, or repair any structure, prior to its issuance, also requires the applicant for the - .person in any manner so as to become subject to the workers' compensation laws of California,
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State - and agree that, if I s houldJ subject to the workers' compensation provisions. of Section
License Law (Chapter 8 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or •' �-20
of the LabQv e, I shall with comply with ose provisions.
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by*�+�.- `
' any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:. ,DateA P -
( ) I, as owner of the property; or my employees with wages as their sole compensation, will do the work, and.'
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The ' WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL '
Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND -
�, and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
improvements are not intended or offered for sale: Ifj however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
one year of.completion,the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT _
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and -Safety for a permit subject to the ,
7044, Business and Professions Code: The Contractors'. State License Law does not apply to an owner of conditions and restrictions set forth on this application. - - • -
.,property -who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1 1. Each person upon whose behalf this applicationis made, each person at whose request and for
pursuant to the Contractors' State License Law.) - - - - whose benefit work is performed under or pursuant to any permit issued as a result of this application,'
1 _ 1 I am exempt under Sec. B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
- performed under or following issuance of this permit.
Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
CONSTRUCTION LENDING AGENCY - permit to cancellation. -
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the 1 certify that I have read this application and state that the ab ' formation is correct. I agree to comply with all
work for which this permit is issued (Sec. 3097, Civ. C.). - city and county ordinances and state laws relating to ng truction, and hereby authorize representatives ,
_ of this court y to enter upon the above-mentio property f spection purposes.
Lender's Name: /
Lender's Address: -Dat�7 i SigriaturelApplicantor: genU:�
LQPERAIIT ; „ '
Application Number
05-00000645
Permit. . . . .
ELEC-NEW RESIDENTIAL
Qty Unit Charge
Per
Extension
.t. 6022.00 .0350
ELEC NEW RES - 1 OR 2 FAMILY
210.77
743.00 .0200
ELEC GARAGE OR NON-RESIDENTIAL
14.86
L.00 15.0000
EA ELEC TEMPORARY POWER POLE
15.00
Permit . .
PLUMBING
Additional desc .
Permit Fee
265.50 Plan Check Fee
66.38
Issue Date
Valuation . . .
0
Expiration Date
12/26/05
Qty Unit Charge
Per
Extension
BASE .FEE
15.00
29.-00 6..0000
-EA -PLB FIXTURE
174.00
1.00 15.0000
EA PLB BUILDING SEWER
15.00
3.00 -,7.50.00
EA PLB WATER HEATER/VENT
22.50..
1.00' 3.0000
EA PLB WATER INST/ALT/REP
3.00
- 1.00 9..0000
EA PLB LAWN SPRINKLER SYSTEM
9.00.
16.00.' .7500
EA- PLB GAS PIPE >_5
12.00
1.00 15.0000
EA PLB GAS METER
Permit
GRADING PERMIT
.Additional' desc .
:,Permit Fee .
-15.00 Plan Check Fee
.00 .
Issue .Date:'
= Valuation
p,
Expiration Date
12/26/05• .
Qty Unit. Charge
Per
Extension
BASE FEE.
15.00
----------------------- ----------- -------
Special Notes and Comments
-------
6022 SQ. FT. SFD. THIS PERMIT DOES NOT
INCLUDE'POOL & SPA BLOCK WALLS OR
DRIVEWAY APPROACH: 3/21/05
6:47:09 AM
JJOHNSON.
Other Fees . .
---------------------------------
.'. . . ART IN PUBLIC PLACES -RES
------------
759.00
DIF COMMUNITY CENTERS -RES
97.00
DIF CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE
133.35
DIF FIRE PROTECTION -RES
97.00
GRADING PLAN CHECK.FEE
.00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
5.00
LQPERMTT
Application Number .
. . . . 05-00000645
------ Structure Information
6022 SQ. -FT. SFD
-----
Construction Type
TYPE V - NON RATED
r Occupancy Type.
. . DWELLG/LODGING/CONG <=10
Flood Zone
NON -AO FLOOD ZONE
Other struct info,
CODE EDITION
2001 CBC
# BEDROOMS
4.00
.'FIRE SPRINKLERS
NO
GARAGE SQ FTG
743.00
PATIO SQ FTG
185.00
NUMBER OF UNITS
1.00
1ST FLOOR SQUARE FOOTAGE.
_
4851.25
2ND FLOOR,SQUARE FOOTAGE
1170.50
Permit
BUILDING PERMIT
:. 'Additional desc
'
Permit Fee,
2051.5.0 Plan -Check Fee
1333.48 -
Issue. Date
Valuation
503602.
Expiration Date
`12/26/05
= Qty. Unit Charge
Per,.
Extension
BASE FEE
2039.50
4.00 3.0000
THOU BLDG 500.;001-1,000,000
12.•.00 "
Permit ".:
MECHANICAL
.Additional desc .
Permit Fee .,
`176.50 -.Plan -Check Fee
44.13
Issue Date . . .
Valuation
0
Expiration Date
12/26/05
Qty Unit Charge
Per _
Extension
BASE FEE
15:00 ....
5.00 9.0000
EA MECH FURNACE <=100K
45.00
5.00 9.0000
EA MECH B/C <=3HP/100K BTU
45.00
_ 10.00 6.5000
EA MECH VENT FAN
65.00
1.00 6:5000EA
MECH EXHAUST HOOD
6.50
Permit
ELEC-NEW RESIDENTIAL
Additional desc
Permit Fee.
255.63 Plan Check Fee
63.91
Issue Date
Valuation . .
0
Expiration.Date..
12/26/05
Qty Unit Charge
Per
Extension
BASE FEE
15.00
Application Number
. . . . .
05-00000645
r ------------------------
-----------
--------
Other.Fees . . .
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI) - RES
50.36
DIF STREET MAINT FAC -RES-
15.00
DIF TRANSPORTATION - RES
1098.00
Fee summary
Charged
Paid Credited
Due
Permit Fee total
2764:13
-------
.00 .00 _--.2764.13
Plan Check Total
1507.90,
'500.00 .00
.1007.90
Other Fee Total
3347.71
00 .00-
3347.71
Grand Total
7619.74
500.00 .00
7119.74
LQPERn4TT -. -
r
P.O. BOX 1504
AP9L C TION ONLYS
Building _ 78-495 CALLS TAMPICO
Address �b L35 ��/R- M i//GL LA QUINTA, CALIFORNIA 92253
Mailing
Address 3s�
City Zip
1-4 Q Lt i n :',4 `F 2 -
2 �z� -A4=iE /?3 f7'6,,r-,__C- 2 -I- C--
2-2- e_1 ?
zL5'? 1?Ti 99Z
& Classif. / / y Lic. #
Arch., Engr.,
Designer
City (Zip (State
Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and
effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5, Business and Aro(essions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes-
sions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon and who does such work himself or through his own employees, provided
that such improvements are not intended or offered for sale. If, however, the building or im-
provement is sold within one year of completion, the owner -builder will have the burden of
proving that he did not build or improve for the purpose of sale).
❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct
the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does
not apply to an owner of property who builds or improves thereon, and who contracts for such
projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKER'S COMPENSATION DECLARATION
hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑ Copy is filed with the city. ❑ Certified copy is hereby furnished.
a
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less).
I certify that in the performance of the work for which this permit is issued, I shall nol
employ any person in any manner so as to become subject to Workers' Compensation Laws of
California.
Date Owner
NOTICE TO APPLICANT.' If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work
for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
WHITE = BUILDING DEPARTMENT
BUILDING: TYPE CONST. OCC. GRP.
A.P. Number_7 % L — S13 C9 —Oa
Legal Description CZ11— % f T/'' -OP-- 2_5!e91!2�
Project Description s ��
Sq. Ft. No. No. Dw.
Size �Q 42_ Stories Units
New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑
Estimated Valuation
PERMIT
Plan Chk. Dep.
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructureffl
r
pip
TOTAL
REMARKS
AMOUNT
a�
r�
r
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by: Date Permit
Validated,by:
Validation:
YELLOW = APPLICANT
PINK= FINANCE
Coachella Valley Unified School District '-his Box For District use only '
83-733 Avenue 55, Thermal, CA 92274 DEVELOPER FEES PAID
(760) 398=5909 — Fax (760) 398-1224
- &REA:
AMOUNT
I EVEL ONE AMOUNT : ,
LEVEL TWO AMOUNT: -
MITIGATION AMOUNT:
COMMAND. AMOUNT:
r ATF.- ,'
RFCF.IPT-
CHF.r.K H,
INITIALfi
s •,
l
CERTIFICATE' OF COMPLIANCE
'(California Mucation Code 17620)
Project Name:
J Date: June 30, 2005
Owner's Name: Palley a. Phone No.
Project Address: 80-235,Via Mirasol La Quinta, CA
Project Description: SFD
APN: 772-430-007 Tract #: - Lot #'s:
Type of Development: Residential XX ;, ,Commercial Industrial
Total Square Feet of Building Area: 6,022 sq. ft.
Certification of Applicant/Owner§r The person signing cerifies thatove information is correct and makes this statement under
penalty of perjury and further represents that he/she is author- deo ehalf of the o r/developer.
Dated: June 30, 2005 Sig urea''
SCHOOL DISTRICT'S REQUIREMENTS FOR THE A3OVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Projecf, Agreement Existing Not Subject to Fee
17620 65995 Approval ,' _ " Prior to 1/1/87 Requirement
Note
Number of Sq.Ft. 6,022
Amount per Sq.Ft. $ 2.88
Amount Collected $ 17,343:36
Building Permit Application Completed: 'Yes/No
By: Carey M. Carlson, Asst. Supt., Business Services
Certificate issued by: Elvira Mattson, Office Techniciar_� Signature:
NOTICE OF 90 DAY PERIOD. FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 30811, effective January 1,. 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or'other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. A3ditionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Ext;nsion will be granted only for.good cause, as determined by the School District, and up
to three (3) such extensions may be granted. At such time as this, Certificate expires, if a building permit has not been issued for the project that is the subject
of this Certificate, the owner will be reimbursed all fees that were paid Eo obtain this Certificate of Compliance.
�1V:cimydocs`cle� lecs,'c irtilicat� o.t iampliluice rorm uible,,TO USEdoe '• , j . 1/16/03 T
. i
PIDPhTy
S1113D.1 ISIp TIONAY�7�,E COMPANY 7,` 7 —/--—�
6, DEPART, r . DOC St M004-0728405
09/14/2004 08:00A Fee:19.00
Page 1 of 5 Doe T Tax Paid
WHEly R$CORDED MAR, TQ Recorded in Official Records
Roger and County of Riverside
Marioa Palley, Famil T Gary L. Orso
121 Via Firenze 3' Y119t'' Assessor, County Clerk 8 Recorder
Newport Beach
CA, 92663 � �'' IIIIIIIIIIIIIIIIIII '
' '.' ., _ IIII III�II VIII VIII III �IIII
IIIIIIII
SSE TAX STATEMENT TO: A M -- — — —
B O VE S U PAQE —�
PCO R HOCOR SNF mrsc
'T 0.2 -ted
DOCUME A R
NT ! R ANSFER TAX 7 COQ -ND NCHG
97.50 � exN,,
y
conve
XX Computed on the consideration or value of propel t e
Y d, OR
Computed on the consideration or value less hens or encumbrances
remaining at the time of sale. N
Signature of Declarant or Agent determining tax — Firm Name
G)R2ANT DEEB ,
FOR A VALUABLE CONSIDERATION, receipt` of which is
herebyacknowledged, NDLA QUINTA PARTNERS, LLC, a Delaware limited liability. company ("Grantor"), herebyGRANTS) to Roger
PATTF9Ml'eyandMarion Palley, ttustees for T, ROGERTRUST dated August 11, 1990 MARION
("Grantee"), the real property located in the City of La Qui»ta, Coun o `
California, described as: tY f Riverside, State of
See Legal Description attached hereto and incorporated herein as Exhibit "A".
SUBJECT TO all matters of record including, without limitation, the covenants
agreements described in Exhibit "A" attached hereto. and
Dated:
ND LA QUINTA PARTNERS, LLC,
a Delaware limited liability company
Ey: Nationwide Realty Investors, Ltd.
an Ohio limited liability company
it$ managing er
B
seph L: Arenson
- . Authorized Representative
le—J VV Li V Val
STATE OF California
COUNTY.OF Riverside
and for SOai r ? 2004, before me, the undersigned, a nota public in
d State, personally appeared Joseph L. Arenson, authorized representative of
Nationwide Realty Investors, Ltd., (whose identity was proved to me on the basis of satisfactory
evidence) to be the person whose name is subscribed to the within instrument and acknowled ed
to me that he executed the same in his authorized capacity, and that b his signatureg
instrument the person, or the entity upon behalf of which the person acted, executed theme
instrument.
WFFNESS MY HAND AND OFFICIAL SEAL.
Signatuure [SEAL] .
CONNIE CONCETTp ,
z . COMM, #141'7229
NOTARY PUBLIC - CALIFORNIA y
RIVERSIDE COUNTY
MY Cammlaslon E�Ires Mcty 11, 2007
. ... _ IJ UUUi UUi1
.EXF1IBIT'4A99
Leeal Description
Farce— l No_l
Lot 7 .(the "Lot") of Amendment No. 2 Tract No. 29894-2, 'in the City of La Quinta, as show
Map on file in Book 359, Pages 68 to 82, inclusive
Recorder of Riverside County, , of Maps, in the Office of the Count n by
California.
y
Califo
EXCEPTING AND RESERVING THEREFROM TO GRANTOR, and its successors
assigns, invitees, licensees and employees, together with the right to '
portion of the same, all easements and rights ;for access, ingress,. gress,eencroa transfer
all or a
maintenance, drainage, support, and for other purposes over the Association Maintenance Areas
and other portion of the Lot, reserved to Grantor in the following instruments:
1 • The Amended and Restated Declaration of Covenants, Conditions and
Restrictions and Reservation of Easements for The hideaway Owners Association (as amended
or supplemented, the "Declaration'), recorded on December 13, 2002, as Instrument No. 2002-
745938, of Official Records of Riverside County, California(the "Official Records");
2. The Supplementary beclaration of Annexation of Property, recorded on August
19;.2004, as Instrument No. 2004-0656071, of Official Records of Riverside Country, California.
FURTHER RESERVING THEREFROM, the right to enter the Lot for a term of
twelve (12) months following the recordation of this Grant Deed, to complete and repair any
improvements or landscaping located thereon as determined necessary by Grantor, in its sole
discretion, .in order to comply with requirements for the recordation of the Final Tract Map, the
grading of said Tract and/or in compliance with the requirements of applicable governmental
agencies. Such entry by Grantor shall be preceded by reasonable notice to Grantee before such
entry. If this reservation of right of entry is not complied with by Grantee, Grantor may enforce
this right of entry in a court of law. Grantee shall be responsible for all damages arising out of
said breach including attorneys' fees and court costs. This reservation of right of entry shall
automatically expire twelve (12) months from the recordation of this Grant Deed.
Parcel No. 2:
Nonexclusive easements for acces
for other s; ingress, egress,, drainage, maintenance, repairs and
purposes, all as described in the Declaration.
SUBJECT TO:
l . Non delinquent general, special and
assessments. supplemental real property taxes and
2.
All other covenants, conditions, restrictions, reservations easements, rights-of-way of record including, without imitation, the Declaration and the Ma f
rights and
Amendment No. 2 Tract No. 29894-2. p or
Grantee, by acceptance and recordation of this Grant Deed, hereby a a
approves a11.of the foregoing in flus Grant De . Y O accepts and
Owners Association such powers and rights as are, set fortth in the Declaratioo Grantor and n, n d(c) ay
covenants and agrees to be bound by and assume performance of all of the applicable provisions
and requirements set forth in the Declaration, includin
for resolving disputes with Grantor, and'the notice,' which provisions and requirements g Section 13.15 establishing thepasocedure
acknowledged to be reasonable and incorporated herein by this reference thereto. Thisant f
conditioned upon the performance of such, provisions and requirements as are to be erF� s
Grantee under the Declaration. The restrictions on use and occupancy of the Lot are set forth my
the Declaration to,wthis Grant Deed is specifically and expressly made subject.
GRANTEE HEREBY ACCEPTS AND APPROVBS THE FOREGOING
Grantor and The Hideaway Ovvn As�iafion Owersazzting unto
Declaration defiined above, onp and rights which are set forth in the
2004.
T A ARION PALLEY FAMILY TRUST
anon Palley, Trustee
COUNTY OF ) ss.
On
public in and for saeid' r > 2004, before me, the undersigned a
State, personally appeared Roger Palley and Marion Palley,
notary
known .to me (or proved to me on the basis of satisfactory evidence) to be the persons whosely
names are subscribed to the within instrument and acknowledged to me that they executed the
same in their authorized capacities, and that by their si
the entity upon behalf of which the persons acted, executed the nature on sh�ent.
anent the persons, or
WITNESS MY HAND A.ND OFFICIAL.SEAL.
.Signature ` [SEAL] , .' o
TAMERA DOUGLAS
N COMM. #1428646
V NOTARY PUBLIC - CALIFORNIA,
.. ORANGE COUNTY p
My commission expires: My Comm. Exolree July 10, 2007
*Engineering •Architecture•Surveying• Buil+ding & Safety Services • '
Letter 'of Transmittal
To: City of La Quinta + Date. . 6/25/05, `
Project Palley Residence
The Hideaway
Attn: Ed Randall .,, PC#: 05-0645(2 check) ,
Tel No.: (760) 777-7012. Tract No.-
We
o3
., ,
' We are forwarding: X By Messenger By Mail Your Pickup
No. of Copies Description: ,r .
1 Plan _
1 Struct. Calcs -
1 Truss ,
1 Redlined Plans '
1 Redlined Struct. Calcs `
Comments: Structural contents are approvable
Thanks
This Material Sent for: - r
Your Files Per Your Request ,
Your Review • ' X Approval
Checking At the request of:
Other,
By: N@lin P@chunuri
Phone # 760-360-5770
` - 77-804 Wildcat Drive; Suite C, Palm Desert, CA: 92211 -(760) 360-5770 _
' Bronz Young
May 12 06 03:21p Brian Monroe 760 771 2759 p.1
,
r ^ . R F STRUCTURAL CONSULTANTS, INC.
75-153 MERLE DRIVE, SM— B, PALM DESERT, CA 92211
` PHONE (760) 836-1000 - FAX(760)836-0856
f' E-MAIL RAYMOND@RFSTRUCTURAL.COM
o- ' ` _ ' ,r. 'o`• ,y' }.j.', j., , ,`,' a .•
APRIL. 25, 2006 t. A "� ';, , • .
• .
PETER JACOBS HOMES, INC:
51-625 DESERT CLUB DRIVE, SUITE 205
LA QUINTA, CA. 02247 s t r -
Attm: I& PETER JACOBS 7
Re. • THE PALLEY RESIDENCE
THE HIDEAWAY, LOT # 7 -
80-235 VIA MIRASOL'• `•s "
LA QUINTA, CA
FOLLOW-UP TO WALK 'THROUGH T
JOB NO_ 4291 t r., -
DEAR
iDEAR PETER
THIS LETTER ADVISES -THAT WE HAVE OBSERVED THE STRUCTURAL
REQUIREMENTS'THAT ARE •VISIBLE DURING CONSTRUCTION AT THE TIME OF
OUR SITE VISIT. , - ' " .{ • 3 R
A.41
WE BELIEVE THAT THE AS—BUILT CONSTRUCTI¢i4 AT THE TIME OF OUR• VISIT IS
IN GENERAL CONFORMANCE WITH OUR STR.UCTURAL.PLANS AND RELEVANT `
CORRESPONDENCE ISSUED BY OUR OFFICE. y,•T ,' r
j41
WE OBSERVED THE BUILDING IN ITS FRAM ED;CONDITION PRIOR TO,
.:. INSTALLATION OF DRYWALL AND STUCCO. WE OBSERVED THE VISUAL'AND
ACCESSIBLE STRUCTURAL REQUIREMENTS. (EXCLUSIONS ARE ITEMS SUCH AS:
` FOOTING SIZE AND REINFORC vfENT ..TOP PLATE SPLICES, ROOF SHEATHING,
AND ANY STRAPS ABOVE THE'ROOF SHEATIiEVG.):' ,`.
RESPECTFULLY S
C-Dp_rq
rte'' ND. E'X
P• tF
06 -30 -Ori / t, ;
Civit
.£OF'CAl1F0¢�
ZEYAD FAQIR, PE
Sladdem Engineering,..- -�
8782 Stanton Ave., Suite A,-Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369
39-725 Garand Ln., Suite G, Palm Desert, CA 92211 (760) 772-3893' Fax (760) 772-3895
,November 18, 2004 -% Project No. 544-4759'
' 04-11-887
Peter Jacobs Homes, -Inc. t
P.O. Box 356 O
La Quinta, California 92253
Project: _Hideaway - Lot 7F
Palley Residence '
La Quinta, California 0`l
Subject: Geotechnical Update
Ref: Geotechnical ,Engineering; Report prepared by Earth Systems, Consultants dated
September 01, 2000, File No. 07117-10, Report No. 00-09-772:,
Report of Testing and, Observation During Rough Grading prepared by Earth Systems
Southwest dated August 28, 2002, File No. 07117-11, Report No. 01-07-718.
r ,
Geotechnical Update prepared by Sladden Engineering dated February 25, 2003,
Project No. 544-2199, Report ,No. 03-02-'106.
' Report of Observations and Testing During Fine Grading *prepared by Sladden
Engineering dated August 13, 2003, Project No 544-2199, Report No. 03-04-225. '
As requested, we have reviewed the above referenced geotechnical reports,as they relate to the
design and construction of the proposed single family residence. The project site is identified as
Lot 7F within the Hideaway Golf Club development in the City of La Quinta, California. Itis our
understanding that the proposed' residence will be a relatively lightweight wood frame structure
supported byconventional shallow spread footings and concrete slabs on grade.
The lot was previously graded dur•i.ng.the'rough grading of the 'Hideaway project site and was .
recently regraded. The rough" grading included overexcavation of the native surface soils along
with the placement of engineered fill material to construct the building pads. The recent
regrading included processing the surface soils. along with minor cuts and fills, to construct the
individual building pads. .Some additional overexcavation was performed in-`areas where the
building envelopes were reconfigured The site grading is summarized in the referenced Report.
of Observations and Testing During Rough Grading along with the compaction test results.
,
e
0oveo�berl8L2-2-�ro
O0� ` '`
� ''' � rro���c[No. 544'4759
04-11'887
'
The referenced' reports include' dubono pertaining to the construction of residential
structure foundations. Based upon our review of the referenced reports, it is our opinion d`u t6e
structuraf values included in thel.referenced gradin I g report remain applicable,for the design and
-construction of the proposed resideniial structure foundations.
Because -the lot has been previously rough graded, the r6medial. grading required at this time
aoouuzoe minimal. The building area
moisture conditioned prior 0oprecise grading. The exposed surface should oecompacted *vuthat
� u minimum of9Opor'ent,reladvecompaction is attained prior tofill placement. Any fill material
should be placed {ntbin}i8o at near wpdonuon moisture content and curnpacted to at least 90
`
percent neiubvecompaction.
Allowable �r
~ eaooreo: The -able bearing presoun���mme�ed�the g�diog
.
report prepared lodd6o E� �rin� remain uppl' ' Conventional shallowupread
`6modn8sshould 6ebottonned'into prope6�coompocted�Uonute6alao`iqionucnofl2inches 6e\ovv
lowestadjacent rade. Continuous footingsshould be at least l2inches wide and isolated pad
footings abou}dbeo1least 2feet wide. and isolated pad footings should be
deyi8ned utilizing allowable bearing pressures of J500 1psf and 2000pof, respectively. An
allowable increase of300noffor each uddidfor '
inches m6� depth may beudUzed.ifdesired. The maximum
'allowable bearing pressure should b
e
3000poedallowable bearing
pressures may beincreased 6vone-third for wind
. uodseisoic loading.
The bearing soils
fall within the "very low." expansion catego,y in
accordance with Uniform Code ' criteria. Pertinent 1997 UBC- - .
Seismic Design parameters are summarized onthe attached data sheet. _
If you have questions regarding this, letter or the referenced report, please contact the
^
"^"de`"gpe"'
` 'Respectfullyoubootted.
SLADDEN ENGINEERING
'
`
'
'
Brett L. Anderson
Exp. MO/06
Principal cu'6uee/ -
,
^E^v". ' '
'
Copies: �`4/PeberJacobs Bomeo'Inc.
' ^
'
*mwwenEngp^=e,"*;
� ^
44
November 18, 2004 ' .` -3 Project No. 544-4759
04-11-8.87
1997 UNIFORM BUILDING CODE INFORMATION .
The International Conference of Building Officials 1997 Uniform Building Code contains
♦ substantial revisions and additions, to' the I6arthgLiake engineering section in- Chapter 16.
Concepts contained in the code that Will be relevant to construction of the proposed structure are
summarized below. • •' _ :♦ ,
-Ground shaking is'expected`to' be the -primary hazard most likely to affect the site, based' upon
proximity to significant faults capable of generating -large `earthquakes. Major fault zones ,
considered to be most likely to create strong ground shaking at the site are listed below.
Based on our field observations and understanding of local fgeologicconditions, the soil profile
type judged` applicable to, this site✓is'SD, generally described as stiff,or dense soil. • The site is
located within UBC Seismic `Zone 4. The following table presents additional coefficients and
• ,factors relevant to seismic mitigation for new construction upon adoption of the 1997 code., 1 '
i - 4 l: ,
`Approximate Distance
Fault Type
Fault Zone
cr
From Site. "-'
`(1997 UBC)
San Andreas ' '�
i -4.9.8 km
.' ",Coefficient
[Sanjacinto ' "`
"26 km , ti
. 'A
Based on our field observations and understanding of local fgeologicconditions, the soil profile
type judged` applicable to, this site✓is'SD, generally described as stiff,or dense soil. • The site is
located within UBC Seismic `Zone 4. The following table presents additional coefficients and
• ,factors relevant to seismic mitigation for new construction upon adoption of the 1997 code., 1 '
i - 4 l: ,
..
e ,
a
Seismic.
Seismic
Seismic
..
Near -Source ,
Near -Source,
Seismic.
Seismic
Seismic
- Acceleration.. •
♦ Velocity;
.' ",Coefficient
Coefficient
Source
Factor,.Na
Factor, NV*
,• Ca
Cv
San Andreas` -F+
1.01,
t
1.22
'0.44 Na `
0.64 Nv -
[San Jacinto -
1 0 -
r #' 1 t0' s
} ~ 0.44 Na
0.64 N,• -
..
� .. ,\,��
- r
tom.♦•
- �
♦Jf,�'y '
6 �
•♦-.
x..`
` f .., + t S • .;r
• , ,ray �♦f,♦ � � � � Y if •� `.•1 � _ -. '�
'� y .
1 -
• - .. `aJ
4
� f� � t .1(�7-' .+V. Y� F � � S
�� 'YY' .. I
�.
.-.
. ` .t
Sladden Engineering
u4a .. � ' ,
. � .'
�..
.. 'T
- �
F7.
�50. Certificate of Compliance:
• Residential
(Part 1 of 2) CFA R
'.The Palley Residence
Exterior
6/8/2005
Project Title
`
Date
The Hideaway La Quinta
Assen-bly
` Location/Comments
Project Address
Type
Building Permit #
BREEZE AIR CONDITIONING (760) 346-0855
Plan Check/Date
Documentation Author
Telephone
Exterior Roof '
Computer Performance
15
Field Check / Date
Compliance Method (Package.or Computer) Climate Zone
Enforcement Agency Use Only
GENERAL INFORMATION
0.327
Exterior Door
Total Conditioned Floor Area:
6,022 fe Average Ceiling Height: 10.2 ft
Total Conditioned Slab Area:
4,851 f?
Slab On Grade
Building Type:
0.756
Covered Slab w/R-0.0 Perimeter Insulation
(check one or more)
a;
(North)
X❑ Single Family Detached
❑ Addition.
0.30
❑ Single Family Attached
❑ Existing Building ,
❑
❑ Multi -Family
❑ Existing -Plus Addition '
X❑
Front Orientation: (North) 0 de_ Floor Construction Type: ®
Slab Floor
Number of Dwelling Units:
1.00
0.38
Number of Stories:
2 ❑
Raised Floor
OUILUINU 5HLLL IN,ULA I IUN
Area
Fenestration
Exterior
Overhang Side Fins
Cont.
Component
Frame
Assen-bly
` Location/Comments
Type
Type
U -Valle
(attic, garage, typical, etc.)
R-38 Roof (R.38.2x14.16)
- Wood
0.026
Exterior Roof '
R-21 Wall (W.21.24.16)
Wood
0.057
Exterior Wall .
Solid Wood Door
Wood
0.327
Exterior Door
Slab On Grade
n/a
0.766
Exposed Slab w/R-0.0 Perimeter Insulation
Slab On Grade
n/a
0.756
Covered Slab w/R-0.0 Perimeter Insulation
X❑
Front
(North)
121.3
= 0.38
0.30
Bug
Screen
❑
X❑
FENESTRATION Shadina Devices
Type • Orientation
Area
Fenestration
Exterior
Overhang Side Fins
SF
U -Factor
SHGC
Shading
Yes / No
Yes
/ No
Skylight
10.0
0.68
0.55
None
❑
x❑
❑
x❑
Front
(North)
.122.5
0.39
0.28
Bug
Screen
❑
X❑
❑
X❑
Front
(North)
121.3
= 0.38
0.30
Bug
Screen
❑
X❑
❑
X❑
Front
(North)
93.0
0:35:
0.38
Bug
Screen
❑
X❑
❑
X❑
Left
(East)
255.2
0.35
0.38.
Bug
Screen
❑
x❑
❑
x❑ ,
Rear
(South)
157.0
0.38
_ 0.30
Bug
Screen
❑
x❑
❑
x❑
Rear
(South)
107.8
0.35
0.38
Bug
Screen
❑
x❑
❑
X❑
Right
(West)
53.6
0.38,
0.30
Bug
Screen
❑
x❑
❑
X❑
Right
(West)
165.0
0.39
0.28 . , ,
Bug
Screen
❑
X❑
❑
a
Front
(North)
80.0
0.39
0.28
Bug
Screen
x❑
❑
❑
x❑
Left
(East)
170.6
0.39,
0.28
Bug
Screen
❑
x❑
❑
x❑
Right
(West)
34.6
0.39
0.28
Bug
Screen
Q
❑
❑
0
Run Initiation Time: 06/08/05 14:40:19 ` Run Code: 1118266819
Ener Pro 3.1 By Ener
Soft
User Number: 3665
Job Number:
Page: 3 of 46
Certificate of Compliance. , Residential
(Part I Of 22 CF -1 R
The Palley Residence
6%8/2005
Project Title
Overhang Side Fins
Date
The Hideaway La Quinta
SF
U -Factor
Project Address
Shading
Building Permit # .
BREEZE AIR CONDITIONING (760) 346=0855 Plan Check / Date
Documentation Author
Telephone
34.6
Computer Performance
15
Fiela,Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION '
Rear
(South)
Total Conditioned Floor Area:
6,022 fe ' Average Ceiling Height: 10.2 ft
Total Conditioned Slab Area:
4,8511W
❑ x❑
Building Type:
_
_
(check one or more)
0.35
0.38
X❑ Single Family Detached
EJ Addition
❑ a
❑ Single Family Attached
❑ Existing Building ,
8.0
❑ Multi -Family .
❑ Existing 'lus Addition
Bug Screen
Front Orientation: (North)
0 deq Floor Construction Type:
® Slab Floor
Number of Dwelling Units:
1.00
Number of Stories:
2
❑ Raised Floor._
BUILDING SHELL INSULATION
Cons::.
Component Frame Assemly 'Location/Comments'
Type - Type U -Value (attic, garage, typical, etc.)
FENESTRATION
Shadinn nPvir_ps
Type
Orientation
Area
=enestration
Exterior
Overhang Side Fins
SF
U -Factor
SHGC -_
Shading
Yes / No
Yes / No
Left
(East)
34.6
0.39
0.28
Bug Screen
x❑ ❑
❑ x❑
Rear
(South)
124.1
0.39
0.28
Bug Screen
❑ x❑
❑ x❑
Right
(West)
406.8
0.35
0.38
Bug Screen
❑ a
❑ a
Left
(East)
8.0
0.38
0.30
Bug Screen
❑ x❑
❑ x❑
❑ ❑
❑ D
❑ ❑
D D
❑ ❑
❑ ❑
❑ ❑
❑ D
El El
a❑.
1:1 El
El F-1
Run Initiation Time: 06/08/05 14:40:19 Run Code: 1118266819
Ener
Pro 3.1 By Ener
Soft '
User Number: 3665
Job Number:
Pa •e:4 of 46
'OMPLIANCE STATEMENT '
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24,`Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: Name: CJ McFadden
Title/Firm: Charles L. Howell Company ' Title/Firm: BREEZE AIR CONDITIONING
Address: 570 Glenneyre Street Address: 75-145 ST. CHARLES PLACE
Laguna Beach, CA 92651 PALM DESERT, CA 92211. '
Telephone: 949 497-2134 Telephone: (760) 346-0855
Lic. #
(signature) (date) (signature) (date)
-Enforcement Agency -
Name:
Title/Firm: `
Address:
Telephone:
(signature/stamp) (date)
Y
- D... 1.-:L:��:�.- T:... nCln�/Ar •�.in.In n... I�_�_. •��nnnwn�n
iEnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:5 of 46
Certificate of Compliance:. Residential
(Part 2 of 2) '
CF -1 R
The Palley Residence
6/8/2005
Project Title
Date
HVAC SYSTEMS Note: Input Hydronic or combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping
Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value •
Type Comments
Central Furnarp 80%AFUE Ducts in Attic 42
Ducts
Setback HVAC #1 .
Centmi F-irnace 80%a AFUE in Attic 42
Central Furnace 80% AFUE Ducts in Attic 4.2
Setback HVAC #2
Setback HVAC #3
Central Furnacp 80% AFUE Ducts in Attic 4.2
Setback HVAC #4
Central Furnace 80% AFUE Ducts in Attic 4.2
Setback HVAC #5
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct
Thermostat Location /.
heat pump, evap. cooling) (SEER) (attic, etc.)` R -Value
Type Comments
Split Air Conditioner 14.0 SEER Ducts in Attic 4.2
Sethark HVAC #1
Split Air Conditioner 14.0 SEER- Ducts in Attic : 4.2
Split Air Conditioner.. 14.0 SEER'- Ducts in Attic 4.2
Setback HVAC #2'
Setback H"C #3
Split Air Conditioner - 14.0 SEER Ducts in Attic 4.2
Split Air Conditioner 14.0 SEER Ducts in Attic 4.2
Setback HVAC 44
Setback HVAC #5
WATER HEATING SYSTEMS
Rated, 1
Tank Energy Facts 1
External
Water Heater Water Heater,. Distribution_.. # in Input `
Cap. or Recovery Standby
Tank Insul.
System Name Type Type Syst. Btu/hr
(gal) ' Efficiency Loss (%)
R -Value
A.0 -Smith FGR -75 Large Gas Recirc/Time+Temp 3 76._000
75 0.72 0-0000
0.0
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor..
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
RFMORKS
'OMPLIANCE STATEMENT '
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24,`Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation Author
Name: Name: CJ McFadden
Title/Firm: Charles L. Howell Company ' Title/Firm: BREEZE AIR CONDITIONING
Address: 570 Glenneyre Street Address: 75-145 ST. CHARLES PLACE
Laguna Beach, CA 92651 PALM DESERT, CA 92211. '
Telephone: 949 497-2134 Telephone: (760) 346-0855
Lic. #
(signature) (date) (signature) (date)
-Enforcement Agency -
Name:
Title/Firm: `
Address:
Telephone:
(signature/stamp) (date)
Y
- D... 1.-:L:��:�.- T:... nCln�/Ar •�.in.In n... I�_�_. •��nnnwn�n
iEnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:5 of 46
Certificate of Compliance: Residential (Addendum) CF -1 R
The Palley Residence 6/8/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written fustification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. I Plan I Field
The HVAC System "HVAC #1 " must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
HIGH MASS Design(see C -21R) - Verify Thermal Mass: 675 sqft Tile in Mortar Interior Mass, 0.75" thick at Boys & Girls Suite/Media/De
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 675 sqft Exposed Slab Floor, 4.00" thick at Boys & Girls Suite/Media/Den
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 904 sqft Covered Slab Floor, 4.00" thick at Boys & Girls Suite/Media/Den
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 225 sqft Tile in Mortar Interior Mass, 0.75" thick at Guest Suite/Gallery/Laundry
HIGH MASS Design(see C -21R) - Verify Thermal Mass: 225 sqft Exposed Slab Floor, 4.00" thick at Guest Suite/Gallery/Laundry
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 645 sqft Covered Slab Floor, 4.00" thick at Guest Suite/Gallery/Laundry
The HVAC System "HVAC #4" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
HIGH MASS Design(see C -21R) - Verify Thermal Mass: 968 sqft Tile in Mortar Interior Mass, 0.75' thick at Reception/Entry
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 968 sqft Exposed Slab Floor, 4.00" thick at Reception/Entry
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 108 sqft Covered Slab Floor, 4.00" thick at Reception/Entry
The HVAC System "HVAC #5' must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
HIGH MASS Design(see C -21R) -Verify Thermal Mass: 1193 sqft Tile in -Mortar Interior Mass, 0.75' thick at Kitchen/Dining/Family
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. I Plan I Field
The HVAC System "HVAC #1 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC #1 " is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC #2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC #2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC #3 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC #3 " is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC #4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow..
Run Initiation Time: 06/08/05 14:40:19 Run Code: 1118266819
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:6 of 46
a
i
-1 -Certificate of Compliance,: Residential (Addendum) CF -1 R
The Palley Residence 6/8/2005
' Project Title Date
Special Features and Modeling Assurriptions ._ r
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The focal
anfnrcpmont anpriry datarminac the arlanimry of tho 9nctifirafinn and may raiart a huildinn nr docinn that nthanuica rrmmnliac
oasea on the adequacy of the special justification and documentation submitted:
Plan' Field
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1193 sqft Exposed Slab Floor, 4.00" thick at Kitchen/Dining/Family
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 133'sgft Covered Slab, Floor, 4.00"thick atKitchen/Dining/Family
s
HERS Required Verification ,
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
proviaer. i ne HtKS rater must aocument the tiela verification and diagnostic testing of these measures. on a form GF -6R.
plan •
Fie_ Id
The HVAC System "HVAC #4" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage •.
performed by a certified HERS Rater: The results of the diagnostic testing must be.reported on a CF -6R Form:
The HVAC System "HVAC #5" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow..
The HVAC System "HVAC #5" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed.by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF-6R.Form. .
A.
Ir I
i:. .
Run Initiation Time: 06/08/05 14:40:19 Run Code: 1118266819
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number:. Page:? of 46
Mandatory Measures Checklist:' Residential (Page 1 of 2) MF -1 R
NOTE: Lownse residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION -instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Building Envelope Measures
❑X -§ 150(.): Minimum R-19 ceiling insulation.
❑ §150(b): Loose fill insulation manufacturer's labeled R -Value.
§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
❑e
X not apply to exterior mass walls).
❑ *§150(d): Minimum R-13 raised floor insulation in framed Floors or equivalent.`
❑§,150(1):, Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
§118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® §116-17: Fenestration Products, Exterior Doors and Infiltration/Ex-filtration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification:
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑ § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have: ,
a. Closeable metal or glass door ,
b. Outside air intake with damper and control ,
c. Flue damper and control
5
2. No continuous burning gas pilots allowed. "
Space Conditioning, Water Heating and Plumbing System Measures
§110-13: HVAC equipment, water heaters, showerheads'and faucets certified by the Commission.
❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA.
❑§150(i): Setback thermostat on all applicable heating and/or cooling systems.
X §150(j): Pipe and Tank Insulation
❑
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined intemal/extemal insulation. t
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank:
t
EnergyPro 3.1' By EnergySoft User Number: 3665 Job Number: Page:B of 46
Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning,' Water Heating and Plumbing System Measures:, (continued)
X❑ '§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 6-3; ducts insulated to,a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. Openings shall.be sealed with mastic,+tape, aerosol sealant, or other duct -closure system--
ystem-that
thatmeets the applicable requirements of UL181, UL181A, or UL1816. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not,
'
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be -
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts. ,
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
duct tapes unless such a tape is used in combination with mastic and draw_bands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily'accessible; manually
operated dampers. .
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight; moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with•a coating that is water retardant and provides shielding
}
from solar radiation that can cause degradation of the material.
❑ §114:, Pool and Spa Heating Systems and Equipment
4 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance
heating, and no pilot. • r
2. System is installed with at least 36" of pipe between filter and heater for future.solar, cover for outdoor pools or,
spas. 1
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch. a ,
JTJ §1`15: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) •" .
❑§118 (f): Cool Roof material meet specified criteria
y
Lighting Measures °
§150(k)l: Luminaires for general lighting in,kitchens shall have lamps with an efficacy 40 lumens/waft or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen. '
R§150(k)2: Rooms with a shower or bathtub must have.eitlier�at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover] approved.
Computer Method Summary (Part 1 of 3) C -2R
The_P_alle_y-3e5.idence
❑ Raised Floor ❑X Slab Floor
Type
Area
61.812005
Project Title
.Ro.o.L_
1,] 64
-0-02-6- 345
Date
The_kl ide.awa-y-La_0 Uinta
362
-0-057- 0_
90_
Wall_
Project Address
-0-0.57- 9.0
90_
Wall_
Building Permit #
AIR C011DIT1OlV.Y.N_G
_90-
90Wall_
-Wall-
(760) 346-0855
Q 057_ _2.7_0
_BBFF7F
Documentation Author
.Ro_oL_
925
Telephone
plan Check/Date
Compute", etEormaace
293
V
15
.Door
Field Check/Date
Compliance Method (Package or Computer)
Climate Zone
441
Source Energy Use
Standard
Proposed
Compliance
0.0.57_ 1.8.0.
(kBtu/sf-yr)
Design
Design
Margin
90
Space Heating
4.90
3.92
0.98
Wall-
Space Cooling
37.33
34.87
2.46
6.5
Domestic Hot Water
4.73
3.46
1.28
_0_057_ 180
Totals
46.97
42.25
4.72
90_
better than Standard:
Total Conditioned Floor Area:
Building Type:
Building Front Orientation:
Number of Dwelling Units:
Number of Stories:
BUILDING ZONE INFORMATION
Zone Name
6,022 ft2
Single Fam Detached
(North) 0 deg
1.00
2
Floor Area Volume
OPAQUE SURFACES Act.
❑ Raised Floor ❑X Slab Floor
Type
Area
U -Fac. Azm.
Tilt
.Ro.o.L_
1,] 64
-0-02-6- 345
0
Wall-
362
-0-057- 0_
90_
Wall_
_267-
-0-0.57- 9.0
90_
Wall_
427-
Q057_ 1.80
_90-
90Wall_
-Wall-
_209
Q 057_ _2.7_0
90
.Ro_oL_
925
-0-026 -345
0
Wall_
293
09.57_ 0
_90 -
0.Door
.Door
20
0_a87 090
Wall_
441
0057_ 90
90
Wall-
381
0.0.57_ 1.8.0.
90,
Wall_
292
3.057_ 3Z0
90
.Roo.L_
300
-0-026 345-
0
Wall-
246_
0_0.57_ 0-
90
Wall-
6.5
0.057 .9.0
90_
Wall_
_2.9.0
_0_057_ 180
_90-
0_Wall_
Wall
201
00.57 _27_0
90_
.Rooms
_x.076
_0_026_ _345
-0-
0Wall_
-Wall-
_2.44
-0-0.57- 0
9.0_
Wall-
X09
-0-057 90
90
Wall-
244
Q.057 1.80
90
Wall_
354
-0,,057- _2Z0
90
.Ro.ot_
1.,326_
_0_026. 345-
-0-
0_Wall-
-Wall
514
-0._057- 0
90_
Wall_
_281
-0-057- _9.0
90_
Wall_
43.9
-0.0.5.7- 18.0
90_
Wall_
262
-0-057- ___2Z0
90
1 170
1-57-9
870.
1-07
Solar
Gains
Y/N
10,534
1_4,211
7,83.0
_15.0654
10.0%
Floor Construction Type:
❑ Raised Floor ❑X Slab Floor
Total Fenestration Area: 32.3%
Total Conditioned Volume: 61,231 ft 3
Total Conditioned Slab Area: 4,851 ft 2
# of
Thermostat Vent
Units Zone Type
Type Hgt. Area
_019_ Sleeping
-SleepingS.tat_ 8 _n/a
_0..26_ Conditioned_
-Setback- 8 _n/.a
_0..14 Conditioned_
-Setback- 8 -n/.a
0_18_ Living
_Living -Slat- 8 _n/a
Form 3 Reference
_R_38B0_0fARa8 2x14161
R2] WALCW 21 9 c6 16)
'R-21 WalL0V1L212Y6_16)
R2J_WalL(W_21.2x616)
R21 _LVaIL(W 2] 2x6 ] Al
R38Baof_(R.3B_2x1416)
R_21_V,LaI.L� �1.2t.2x6.16 )
SQidWood_Door
&2_L)LVaIL(1IV_.91.9 16)
R21_W al I_(W_.21.2x6.]6.)
B2] LP -21 6-161
R-38BooL(R 38 2x14.16)
R-21 Wall (W.21 2x6.16)
R21WalL(W_ _21 2x6 16)
R2LWalI (W_2J_2x616.)
R2.1_W a l l� W_.212x6J6 )
R_38.Ro_of_(R_38.2x1A_16)
R2LWa1l_(W.21.2x6 16)
_R2.1_WaI I�W_a2x616)
R2J_Wa1LGVY_2_t2x616)
R21 Wall (y_1L21.2x6_16)
R38_Ro of_(R_38..2x1_4 �16.)
.R_2LWalL(W_2J_ 16)
_R2LV_KalL(W_21 16)
.R21 \L1/alL(_W_21_2x616)
R2LWalL(W 21..2x616)
.ZO.NF#2
.ZONE #2
ZO.NE13
ZO.NE4
ZO.NE#_4
ZONE
.ZONE #4
ZO.NF9
.ZONE -#5
.ZO.NE�5
.ZONE -ES
.ZONE-#.-';
ZONES
Location / Comments
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 10 of 46 1
M
Computer Method Summary
(Part 1 of 3) C -2R
Jhe-Ralle_y-esidence
`
6/R120Q5
Project Title
Jhe_kl.ideaw-ay—La_Q.uinta
Date
Project Address
Building Permit #
0NING
(760) 346-0855
_BREEZEAIEZC0_N.D1Z
Documentation Author
Telephone
plan Check/Date
COnm�p- -if ormance
15
Field Check/Date
Compliance Method (Package or Computer)
Climate Zone
Source Energy Use Standard
Proposed
Compliance
(kBtu/sf-yr) Design
Design
Margin
Space Heating 4.90
3.92
0.98
Space Cooling 37.33
34.87
2.46
Domestic Hot Water -4 * 73
3.45
1.28
Totals 46.97
42.25
4.72
Percent better than Standard:
10.0%
Total Conditioned Floor Area: 6,022 ft2
Building Type: Single Fam Detached
Building Front Orientation: (North) 0 deg
Number of Dwelling Units: 1.00
Number of Stories: 2
r p
BUILDING ZONE INFORMATION
Zone Name Floor Area
_H_V21 39
,31
OPAQUE SURFACES pi
Act. Gaainn
s
Type Area U -Fac. Azm. Tilt Y / N
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑❑ '
❑ ❑
❑❑
F ❑
F-1 F1
❑❑
F-1 F1
❑❑
❑❑
❑❑
nn
Floor Construction Type: ❑ Raised Floor ❑X Slab Floor
Total Fenestration Area: 32.3%
Total Conditioned Volume: 61,231 ft 3
Total Conditioned Slab Area: 4,851 ft 2
# of
Volume Units
X3,532 `-0.2Z
Form 3 Reference.
Zone Type,
I wing
Thermostat Vent
Type Hgt. Area
I ivingS.tat— 8 _n/.a
Location / Comments
Kun mluation Ilme: uotuo/up14:4u:1!J Kun Goae: iliazwml`J
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:11 of 46
Computer Method Summary (Part 2 of 3) C -2R
The Palley Residence 6/8/2005
Project Title Date
FENESTRATION SURFACES
. U- Act. Glazing Type Location/
# Type Area Factor SHGC _azm. Tilt Comments
1
Skyligbt_Etont (Xodh)
6_0_
0-6.8.0
-0-5.5
_34.5_
0. fiolalube_(DefaWi)_Skylite
ZONE -#1
2
Window
Front
(North)
40.0
0.390
0.28
0
90 Sierra Pacific Clad (Lo/E)
ZONE #1
3
Window
Front
North
25.0
0.380
0.30
0
90 Sierra Pacific Clad (Lo/E)
ZONE #1
4
Window
Front
(North)
25.0
0.350
0.38
0
90 Sierra Pacific Clad (Lo/E)
ZONE #1
5
Window
Front
North
11.3
0.380
0.30
0
90 Sierra Pacific Clad (Lo/E)
ZONE #1
6
Window
Front
North .
11.3
0.380
0.30
0
90 Sierra Pacific Clad (Lo/E)
ZONE #1
7
Window
Front
'-(N orth)
7.0
0.380
0.30
0
9Q Sierra Pacific Clad (LQ/E)
ZONE #1
8
Window
Left
(East)
30.4
0.350
0.38
90
90 Sierra Pacific Clad (Lo/E)
ZONE #1
9
Window
Rear
(,South)
7 Q
0,380
0.30
180
90 Sierra Pacific Clad (Lo/E)
ZONE #1
1Q
Win ow
Rear
(-SQ h)
7Q
0.380
0.30
180
9Q Sierra Pacific Clad ME)
ZQNE #1
11
Window
Rear
(South)
20.0
0.380
0.30
180
90 Sierra Pacific Clad (Lo/E)
ZONE #1
12
Window
Rear
South
10.5
0.350
0.38
180
90 Sierra Pacific CladL( o/E)
ZONE #1
13
Window-RZea> (.SoLdh)
10.5
Q350
0..38
180_
9Q SiefCaP_aclflc Clad (Lo/E)
ZONE -#1
14
Window
Right
West
8.0
0.380
0.30
270
90 Sierra Pacific CladL( o/E)
ZONE #1
15
Window
Right
fflNest
40.0
0.390
0.28
270
90 Sierra Pacific Clad (Lo/E)
ZONE #1
16
Window
Ri hg test
40.0
0.390
0.28
270
90 Sierra Pacific Clad (Lo/E)
ZONE #1
17
dight
Front
(North)
4.0
0.680
0.55
345
0 SolaTube (Default) Skylite
ZONE #2
18
dight
Front
North
0.0
0.800
0.43
345
0 Bristolite Skylite
ZONE #2
19
Window
Front
(North)
�4 2
0.390
0.28
0
9Q Sierra Pacific Clad (Lo/E)
ZONE #2
20
Window
Front
North
40.0
0.390
0.28
0
90 Sierra Pacific CladL( o/E)
ZONE #2
21
Window
FrontN(
orth)
11.3
0.380
0.30
0
90 Sierra Pacific Clad (Lo/E)
ZONE #2
22
Window
Front
(North)
20.0
0.350
0.38
0
90 Sierra Pacific CladL( o/E)
ZONE #2
23
Window
Left
(East)
34.6
0.390
0.28
90
90 Sierra Pacific Clad (Lo/E)
ZONE #2
24
Window
Left
(East)
19.3
0.350
0.38
90
90 Sierra Pacific CladL( o/E)
ZONE #2
25
Window
Left
East _
19.3
0.350
0.38
90
90 Sierra Pacific Clad (Lo/E)
ZONE #2
26
Window
Rear
(South)
8.0
0.380
0.30
180
90 Sierra Pacific Clad (Lo/E)
ZONE #2
27
Window
Rear
(South)
27.5
0.380
0.30
180
90 Sierra Pacific Clad (Lo/E)
ZONE #2
28
Window
Rear
(South)
27.5
0.380
0.30
180
90 Sierra Pacific Clad (Lo/E)
ZONE #2
29
Window
Rear
(South)
27.5
0.380
0.30
180
90 Sierra Pacific Clad (Lo/E)
ZONE #2
INTERIOR AND EXTERIOR SHADING'
Window
Overhang Left Fin
Right Fin
#
Exterior
Shade Type
SHGC
Hgt.
Wd.
Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. . Len. Hgt.
1
None
1.00
2
Bug Screen
0.76
3
Bug Screen
0.76 _
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76 _
7
Bug Screen
0.76
8
Bug Screen0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
-0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
Bug Screen
0.76
17
None
_
1.00
18
None
1.00
19
Bug Screen
0.76 8.0 5.0 8.0 0.1 8.0 8.0
20
Bug Screen
0.76 8.0 5.0 8.0 0.1 8.0 8.0
21
Bug Screen
_
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
_
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
_
0.76
28
Bug Screen
_
0.76
29
Bug Screen
_
0.76
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:12 of 46
Computer Method Summary (Part 2 of 3) C -2R
The Palley Residence 6/8/2005
Project Title Date
FENESTRATION SURFACES
# Type
Area
U-
Factor
SHGC
Act.
Azm.
Glazing Type
Tilt
Location/
Comments
_30.
Window Rear (S.o.utb.)
10_5_
0_3.8.0
-0_30_
_58.0_
_90 SierraP_aciflc_CJad_(Lo/E)
ZONE -#2
31
Window Right (West)
34.6
0.390
0.28
270
90 Sierra Pacific Clad (Lo/E)
ZONE #2
32
Window Right (West)
19.3
0.380
0.30
270
90 Sierra Pacific Clad (Lo/E)
ZONE #2
33
Window Right (West)
19.3
0.380
0.30
270
90 Sierra Pacific Clad (Lo/E)
ZONE #2
34
Window Front (North)
40.0
0.390
0.28
0
90 Sierra Pacific Clad (Lo/E)
ZONE #3
35
Window FrontNorth .
30.0
0.350
0.38
0
90 Sierra Pacific Clad (Lo/E)
ZONE #3
56
Window LeftE( astl_
40.0
0.350
0.38
90
90 Sierra Pacific Clad (Lo/E)
ZONE #3
37
Window Left (East)
40.0
0.350
0.38
90
90 Sierra Pacific Clad (Lo/E)
ZONE #3
38
Window Left (Eases
34.6
0.390_
0.28
90
90 Sierra Pacific Clad (Lo/E)
ZONE #3
39
Window Rear (Sou1L)
8.0
0.380
0.30
180
90 Sierra Pacific Clad (Lo/E)
ZONE #3
40
Window Rear (South)
26.6
0.390
0.28
180
90 Sierra Pacific Clad (Lo/E)
ZONE #3
41
Window Right (West)
7.0
0.380
0.30
270
90 Sierra Pacific Clad (Lo/E)
ZONE #3
_4.2.
Windowl3igtit (_West).
18 6
0,350
0-38
--- 27-0-
-90 Siem-P_acifc-Qad(Lo1E)
_ZON.EA3
43
Window Right est
40.0
0.350
0.38
270
90 Sierra Pacific Clad (Lo/E)
ZONE #3
44
Window Right (West)
18.6
0.350
0.38
270
90 Sierra Pacific Clad (Lo/E)
ZONE #3
45
Window Right West
40.0
0.350
0.38
270
90 Sierra Pacific Clad (Lo/E)
ZONE #3
46
Window Front (North)
42.5
0.390
0.28
0
90 Sierra Pacific Clad (Lo/E)
ZONE #4
47
Window Left (East)
3.8
0.350
0.38
90
90 Sierra Pacific Clad (Lo/E)
ZONE #4
40
Window Left (East)
42.5
0.390
0.28
90
90 Sierra Pacific Clad (Lo/E)
ZONE #4
49
Window Left East
51.0
0.390
0.28
90
90 Sierra Pacific Clad (Lo/E)
ZONE #4
50
Window Left (East)
3.8
0.350
0.38
90
90 Sierra Pacific Clad (Lo/E)
ZONE #4
51
Window Left (East)
42.5
0.390
0.28
90
90 Sierra Pacific Clad (Lo/E)
ZONE #4
52
Window Rear (South)
42.5
0.390
0.28
180
90 Sierra Pacific Clad (Lo/E)
ZONE #4
53
Window Right (West)
3.8
0.350
0.38
270
90 Sierra Pacific Clad (Lo/E)
ZONE #4
54
Window Right (West)
42.5
0.390
0.28
270
90 Sierra Pacific Clad (Lo/E)
ZONE #4
55
Window Right (West)
25.6
0.350
0.38
270
90 Sierra Pacific Clad (Lo/E)
ZONE #4
56
Window Right (West)
55.0
0.350
0.38
270
90 Sierra Pacific Clad (Lo/E)
ZONE #4
57
Window Right (West)
25.6
0.350
0.38
270
90 Sierra Pacific Clad (Lo/E)
ZONE #4
58
Window Right (West
3.8
0.350
0.38
270
90 Sierra Pacific Clad (Lo/E)
ZONE #4
INTERIOR AND EXTERIOR SHADING
Window
Overhang Left Fin Right Fin
#
Exterior Shade Type
SHGC
Hgt. Wd.
Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt.
30
Bug Screen
0.76
0.76
53
31
Bug Screen
0.76
8.0 4.3
8.0 0.1 8.0 8.0
32
Bug Screen
0.76
56
Bug Screen
33
Bug Screen
0.76
0.76
58
34
Bug Screen
0.76
35
Bug Screen
0.76
36
Bug Screen
0.76
37
Bug Screen
0.76
38
Bug Screen
0.76
8.0 4.3
8.0 0.1 8.0 8.0
39
Bug Screen
0.76
40
Bug Screen
0.76
Ti
Bug Screen
0.76
_
42
Bug Screen
0.76
43
Bug Screen
0.76
_
44
Bug Screen
0.76
45
Bug Screen
0.76
46
Bug Screen
0.76
47
Bug Screen
0.76
48
� Screen
0.76
49
Bug Screen
0.76
50
Bug Screen
0.76
51
Bug Screen
0.76
52
Bug Screen
0.76
53
Bug Screen
0.76
54
Bug Screen
0.76
55
Bug Screen
0.76
56
Bug Screen
0.76
57
Bug Screen
0.76
58
Bug Screen
0.76
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 13 of 46 1
Computer Method Summary (Part 2 of 3) C -2R
The Palley Residence 6/8/2005
Project Title Date
FENESTRATION SURFACES
# Type
Area
U-
Factor
SHGC
Act.
Azm.
Glazing Type
Tilt
Location/
Comments
_5.9.
Window_ Right_(_West)
42.5
_0_39.0
-028
-2Z0_
_90. Siena-Eacific_Clad_(LoLE)
ZONE #4
60
Window Front (North)
8.2
0.380
0.30
0
90 Sierra Pacific Clad (Lo/E)
ZONE #5
61
Window Front (North)
18.0
0.350
0.38
0
90 Sierra Pacific Clad (Lo/E)
ZONE #5
62
Window Front (North)
8.2
0.380
0.30
0
90 Sierra Pacific Clad (Lo/E)
ZONE #5
63
Window Front (North)
13.5
0.380
0.30
0
90 Sierra Pacific Clad (Lo/E)
ZONE #5
64
Window Front (North)
13.5
0.380
0.30
0
90 Sierra Pacific Clad (Lo/E)
ZONE #5
65
Window Front (North)
12.0
0.380
0.30
0
90 Sierra Pacific Clad (Lo/E)
ZONE #5
66
Window Left (East)
8.0
0.380
0.30
90
90 Sierra Pacific Clad (Lo/E)
ZONE #5
67
Window Left (East)
40.0
0.350
0.38
90
90 Sierra Pacific Clad (Lo/E)
ZONE #5
68
Window Left (East)_
40.0
0.350
0.38
90
90 Sierra Pacific Clad (Lo/E)
ZONE #5
69
Window Left _(Eastj
18.6
0.350
0.38
90
90 Sierra Pacific Clad (Lo/E)
ZONE #5
70
Window Rear (South)
19.3
0.350
0.38
180
90 Sierra Pacific Clad (Lo/E)
ZONE #5
_71
Window_Rear(South)
_275
0850
-0-38
X89_
20. Sieua_P_acific_Clad_(Lo/E)
ZONES
72
Window Rear (South)
27.5
0.390
0.28
180
90 Sierra Pacific Clad (Lo/E)
ZONE #5
73
Window Rear (South)
40.0
0.350
0.38
180
90 Sierra Pacific Clad (Lo/E)
ZONE #5
74
Window Rear South
27.5
0.390
0.28
' 180
90 Sierra Pacific Clad (Lo/E)
ZONE #5
75
Window Rear (South)
7.0
0.380
0.30
180
90 Sierra Pacific Clad (Lo/E)
ZONE #5
76
Window Rear (South)
7.0
0.380
0.30
180
90 Sierra Pacific Clad (Lo/E)
ZONE #5
77
Window Right_(West)_
40.0
0.350
0.3$
270
90 Sierra Pacific Clad (Lo/E)
ZONE #5
78
Window Right (West)
40.0
0.350
0.38
270
90 Sierra Pacific Clad (Lo/E)
ZONE #5
79
Window Right (West)
18.6
0.350
0.38
270
90 Sierra Pacific Clad (Lo/E)
ZONE #5
80.
Window Riaht West
18.6
0.350
0.38
270
90 Sierra Pacific Clad (Lo/E)
ZONE #5
81
Window Right est
40.0
0.350
0.38
270
90 Sierra Pacific Clad (Lo/E)
ZONE #5
82
Window Right West _
18.6
0.350
0.38
270
90 Sierra Pacific Clad (Lo/E)
ZONE #5
INTERIOR AND EXTERIOR SHADING
Window
Overhang Left Fin
Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
_en. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt.
59
Bug Screen
0.76
60
Bug Screen
0.76
61
Bug Screen
0.76
_
62
Bug Screen
0.76
63
Bug Screen
0.76
64
gug Screen
0.76
65
Bug Screen
0.76
66
Bug Screen
0.76
67
Bug Screen
0.76
68
Bug Screen
0.76
_
69
Bug Screen
0.76
70
Bug Screen
1 0.76
71
Bug Screen
0.76
72
Bug Screen
0.76
73
Bug Screen
0.76
74
Bug Screen
0.76
75
Bug Screen
0.76
76
Bug Screen
0.76
77
Bug Screen
0.76
78
Bug Screen
0.76
79
Bug Screen
0.76
80
Bug Screen
0.76
81
Bug Screen
0.76
82
Bug Screen
0.76
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paw 14 of 46 1
Computer Method Summary (Part 3 of 3) C -2R
The Palley Residence a "• . • :. ',,.,„
6/8/2005 '
Project Title
Date
THERMAL MAS_ S FOR HIGH MASS DESIGN"
Area' Thick. HeatInside
Location
Type
(so (in.) Cap. Cond. Form3'Reference R -Val.
Comments
Tile in Mortar
67-5. _0J5 _24 _0_67- n/a _0
ZONE-#2llntenor--IV1
Concrete, Heavyweight
675 . 4_00 28 0_98 n/a 0
ZONE #2 / Slab on Grade
Cowl r Heavyweight
904 -A-0 28 , -0-9-a n/a 2
ZONE #2 / Slab on Grade
Tile in Mortar
225 0_75 _24 . 0_67 n/a " 0
ZONE #3 / Interior Mass'
Concrete-FleavyA fight
225 420 28` '0.98 n/a 0
ZONE 03 / Slab on Grade
PERIMETER LOSSES
,• ., : , ,
,
F2 Insulation �.
Type
Length Factor R -Val. Depth , Location / Comments
Slab Perimeter
80 076 00 0 . ZONE #2
Slab— erimeter
U-8 Q26 —0-0 —'0. ZC1NE #2
Slab Perimeter
27 0.76 Q_Q 0 ZONE #3
Slab_P_eumeter.
_100 _0_76 _0 0 - _` _0 ZONE; 3
-Slab— erimete.r
128_0 7Sz —O9 0 ZONE #4
HVAC SYSTEMS
f
Heating Equipment
Minimum 'Distribution Type
Type (furnace, heat
Efficiency and Location - . Duct Thermostat
Location /
pump, etc.)
(AFUE/HSPF)(ducts/attic, etc.) •' R -Value ,Type
Comments
ntral Furnace
80% AFUE Ducts in Attic " • 4.2 Setback
HVAC #1
Central Furnace-
80% AFUE Ducts in Attic, 4.2 Setback
HVAC #2 -
Central Furnace
80% AFUE Ducts in Attic 4.2 Setback'
HVAC #3
Central Furnace
80% AFUE Ducts in Attic 4.2 Setback
HVAC #4
Hydronic Piping .
Pipe Pipe . ' ~ Insul., y r
System Name
Length Diameter Thick.
Cooling Equipment
Minimum ' Duct,
Type (air conditioner,
Efficiency Location Duct Thermostat
Location /
heat pump, evap,,cooling) (SEER) (attic, etc)' R -Value Type
Comments ,
S lit Air Cgnditioner
14.0 SEER Ducts in Attic 4.2' Setback
HVAC #1
Split Air Conditioner
14.0 SEER , Ducts in Attic 4.2 Setback
HVAC#2
Split Air Conditioner
SEER Ducts in Attic 4.2 Setback
HVAC #3
Split Air Conditioner
x..14.0
14.0 SEER Ducts in Attic 4.2 Setback
HVAC #4
y.
WATER HEATING SYSTEMS 1
Rated Tank
Energy Fact. 1 Tank Insul.
Water Heater
Water Heater; Distribution > # in Input. Cap.
or Recovery Standby R -Value
System Name
Type Type Syst. (Btu/hr)-(g.@l) Efficiency Loss (%) Ext. '
A.O.Smith FGR -75.
Larae Gas Recirc/Time+Temp 3 '° 76,000 75
0.72 0:0000 0.0
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy
factor.
For large gas storage water heaters (rated input > 75000 Btu/hr); list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
Run Initiation Time:. 06/08/05 14.40.19 Run Code: 1118266819
EnergyPro 3.1 By EnergvSoft User Number: 3665 Job Number: Page' 15 of 46
{ell
e,
Computer Method Summary (Part 3 of 3) -C-2R
The Palley Residence
y
6/8/2005
Project Title
Date
THERMAL MASS FOR HIGH MASS DESIGN'
Area
Thick. Heat Inside
Location
Type (sf)
-'(in.) Cap. Cond. Form :3-Reference = R-Val.
Comments -
�oncrete Heavvweight _645
X0.0 —28.. • -0_96. n/a _2
20NF_#3JG.lab_on Gr.ade
Tile in Mortar ' 968
0_75 24 0_67 n/a 0,
ZONE #4 / Interior Mass
Cete Heavyweight_ 968
4�. 0 �2 0.98 n/a 0
ZQNE #4 / Slab on Grade
Concrete. Heavyweight 108
4_00 28 0_98. n/a 2
ZONE #4 /Slab on Grade
Tile_in-lAortar 1 193
Q.75 '24, 0.67 n/a 0
ZONE #5 /interior Mass
PERIMETER LOSSES
5 :.
F2 Insulation
Type Length
Factor R-Val. Depth Location] Comments
Slab P e rimder 12
0.76 0.0 0 .' ZONE #4
Stab Rerimeter t69
"_OZ6 -Q-Q —0 ZO_5
SIII Perimeter 19
0.76 1-.0.0. 0 ZONE #5
HVAC SYSTEMS
Heating Equipment..
Minimum Distribution TypF
Type (furnace, heat
Efficiency and Location Duct .Thermostat
Location/
pump, etc.). (AFUE/HSPF)(ducts/attic,
etc.) _ R-Value Type
Comments
central Furnace
80% AF EE Ducts in Attic 4.2 Setback
HVAC #5
Hydronic Piping Pipe .
Pipe Jnsul. k:
System Name Length
Diameter `' ,Thick.
Cooling Equipment
Minimum. Duct
Type (air conditioner,.
Efficiency Location Duct Thermostat
'Location /
heat pump, evap..cooling)
(SEER) (attic; etc,) _; R-Value-`;Type
Comments,
-Split Air Conditioner,
14.0 SEER Ducts in Attic 4.2 . Setback
HVAC #5
WATER HEATING SYSTEMS'
•` ' + ` Ratedl k ' Tank
Energy Facts 1 Tank Insul.
Water Heater
Water Heater' Distribution # in Input Cap.
or Recovery Standby ,R-Value
System Name
Type Type Syst. Btu/hr (gam Efficiency Loss (%) Ext.
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters,, list energy
factor.
For large,.gas storage water heaters
(rated ir)'put > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters,
list Rated Input, and Recovery. Eficiency.
n
v
tEMARKS a
Run Initiation Time: 06/08/05 14:40:19 Run Code: 1118266819
EnergyPro 3.1 By Energysoft User Number: '3665 •' Job Number: Page: 17 of 46
Computer Method Summary, . ' - (Part 3. of 3) C -2R-
The Palley Residence -"' "' ' ` "
6/8/2005
Project Title
Date
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside
Location
Type (sq (in.) Cap. Cond. Form 3 Reference R -Val.
Comments
C9ncrete Heavyweight -.,193 AM _28 _0-98 n _0 ,
. MNEA5LSlab onGrade
Concrete. Heavyweight 133 4_00 28 0_98 n/a 2
N
ZONE #5 / Slab on Grade
PERIMETER LOSSES
F2 Insulation{
Type Length Factor R -Val. Depth Location / Comments
HVAC SYSTEMS
Heating Equipment Minimum 'Distribution Type +
Type (furnace, heat Efficiency and Location Duct Thermostat
Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type
Comments
Hydronic Piping Pipe Pipe - Insul.'J
System Name Length Diameter Thick."
Cooling Equipment Minimum 'Duct.
Type (air conditioner, Efficiency Location Duct Thermostat.
Location /
heat pump, evap. cooling) (SEER) , (attic, etc,) R -Value 'Type
Comments
WATER HEATING SYSTEMS Ratedl Tank
Energy Facts 1 Tank Insul.
Water Heater Water Heater Distribution # in Input Cap.
or Recovery Standby R -Value
System Name Type Type ;[ : Syst. (Btu/hr) (gal)
Efficiency Loss (%) Ext.
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy
factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
tEMARKS a
Run Initiation Time: 06/08/05 14:40:19 Run Code: 1118266819
EnergyPro 3.1 By Energysoft User Number: '3665 •' Job Number: Page: 17 of 46
:.-- Computer Method Summary (Addendum) C -2R
The Palley Residence 6/8/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. I Plan I Field
The HVAC System "HVAC #1 " must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 675 sqft Tile in Mortar Interior Mass, 0.75" thick at Boys & Girls Suite/Media/De
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 675 sqft Exposed Slab Floor, 4.00" thick at Boys & Girls. Suite/Media/Den
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 904 sqft Covered Slab Floor, 4.00" thick at Boys & Girls Suite/Media/Den
HIGH MASS Design(see C -21R) - Verify Thermal Mass: 225 sqft Tile in Mortar Interior Mass, 0.75" thick at Guest Suite/Gallery/Laundry
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 225 sqft Exposed Slab Floor, 4.00" thick at Guest Suite/Gallery/Laundry
HIGH MASS Design(see C -21R) - Verify Thermal Mass: 645 sqft Covered Slab Floor, 4.00" thick at Guest Suite/Gallery/Laundry
The HVAC System "HVAC #4" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 968 sqft Tile in Mortar Iriterior Mass, 0.75" thick at Reception/Entry
HIGH MASS Design(see C -21R) - Verify Thermal Mass: 968 sqft Exposed Slab Floor, 4.00" thick at Reception/Entry
HIGH MASS Design(see C -21R) - Verify Thermal Mass: 108 sqft Covered Slab Floor, 4.00" thick at Reception/Entry
The HVAC System "HVAC #5' must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
HIGH MASS Design(see C -21R) -Verify Thermal Mass: 1193 sqft Tile in Mortar Interior Mass, 0.75' thick at Kitchen/Dining/Family
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -611. I Plan I Field
The HVAC System "HVAC #1 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC #1 " is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC #2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC #2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC #3 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC #3 " is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC #4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
1 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Pam: 18 of 46 1
r t
Computer Method Summary, (Addendum) C -2R
The Palley Residence 6/8/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the it -ams specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement aaencv determines the adeouacv of the iustification. and may refect a buildina or desian that otherwise complies
3ased on the adequacy of the special justification and documentati-3n 'submitted. Plan EField
HIGH MASS Design(see C -2R) -Verify Thermal Mass: 1193 sqft Exposed Slab Floor, 4.00" thick at Kitchen/Dining/Family
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 133 sqft Covered Slab Floor, 4.00" thick at Kitchen/Dining/Family
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. I Plan I Field
The HVAC System "HVAC #4" is using reduced duct leakage to complyand must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "HVAC #5" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow-
irflowThe
TheHVAC System "HVAC #5" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:19 of 46
PROPOSED CONSTRUCTION ASSEMBLY ENV -3
PROJECT NAME DATE
The Pallev Residence 6/8/2005
COMPONENT DESCRIPTION
DESCRIPTION
FRAMING.
OUTSIDE SURFACE AIR FILM
1
Stucco
2
Membrane, Vapor -Permeable Felt
3
Plywood
4
Insulation, Mineral Fiber, R-21
5
ASSEMBLY NAME
R-21 Wall W.21.2x6.16
0.31
7
0.37
8
2.60
ASSEMBLY
Floor
i
INSIDE SURFACE AIR FILM
0.680
23.13
TYPE
(check one)
X Wall
W
Ceiling /Roof
NFRAMING
MATERIAL
Wppd
=O
Z
FRAMING %
15 %c
Framing /a
15% (16" o.c. Wall)
12% (24" o.c. Wall)
10% (16" o.c. Floor/Ceil.)
SKETCH OF ASSEMBLY
7% (24" o.c. Floor/CeiIJ
R -VALUE
DESCRIPTION
FRAMING.
OUTSIDE SURFACE AIR FILM
1
Stucco
2
Membrane, Vapor -Permeable Felt
3
Plywood
4
Insulation, Mineral Fiber, R-21
5
Gypsum or Plaster Board
6
0.31
7
0.37
8
2.60
9
0.68
i
INSIDE SURFACE AIR FILM
R -VALUE
THICK-
NESS
(in.)
FRAMING.
❑
❑
❑
N
❑
El
El
El
0.170
0.875
0.010
0.375
5.500
0.625
0.480
21.000
5.445
0.5621
0.562
R -VALUE
CAVITY
R -VALUE
(Rc)
WOOD
FRAME
R -VALUE
0.170
0.170
0.1751
0.175
0.060
0.060
0.480
0.480
21.000
5.445
0.5621
0.562
0.31
2.63
0.37
0.98
2.60
0.26
0.68
i
0.680
0.680
23.13
7.57
Rc Rf
*HEAT CAPACITY (Optional)
WALL
WEIGHT
(lbs/sf)
SPECIFIC
' HEAT
(Btu/F-Ib)
HC
(A X B)
(Btu/F-sf)
[ .0.0432 X
0.85 ]
8.46
0.20
1.69
0.06
0.35
0.02
1.06
0.29
0.31
2.63
0.37
0.98
2.60
0.26
0.68
i
14.81
TOTAL HC
3.7
*NOTE: Weight and Specific Heat values for materials
penetrated by wood framing
include the effects of the framing
members.
[ .0.0432 X
0.85 ]
+
[ 0.1321
X 0.15
1 / Rc
1 - (Fr-/. / 100)
1 / Rf
Fr% 1100
ASSEMBLY U -VALUE
i
EnergyPro 3.1 By EnergySoft User Number: 3665 o Job Number: ' Page: 20 of 46
J
e
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Palley Residence 6/8/2005
SYSTEM NAME FLOOR AREA
HVAC #1 1,170
Number of Systems
1
Heating System
Output per System
72,100
Total Output (Btuh)
72,100
Output (Btuh/sgft)
61.6
Cooling System
Output per System
48,000
Total Output (Btuh)
48,000
Total Output (Tons)
4.0
Total Output (Btuh/sqft)
41.0
Total Output (sgftrTon)
292.6
Air System
CFM per System
1,600
Airflow (cfm)
1,600
Airflow (cfm/sqft)
1.37
Airflow (cfm/Ton)
400.0
Outside Air (%)
5.5
Outside Air (cfm/sgft)
0.07
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
I COIL HTG. PEAK
CFM
I Sensiblel
Latent
I CFM
I Sensible
1,279
26,200
3,010
344
14,280
0
1,310
714
0
0
88
3,349
2,03
88
4,320
0
0
1,310
714
32,170 5 04 20 028
HS26-048/G40UH48B-090X (4) 38,758 3,846 72,100
Total Adjusted System Output 38,758 3,846 72,100
(Adjusted for Peak Design Conditions)
TI ME OF SYSTEM PEAK Aug 2 pm Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temroeratures at Time of Heating Peak
24.0 OF 67.1 OF 108.8 OF 108.8 OF
Supply Air Ducts
Outside Air C,0..
88 cfm Heating Coil Supply Fan 108.4 °F
1600 cfm ROOMS
69.6 OF 70.0 OF
ih Return Air Ducts I
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
114.1 / 80.3 OF 80.7 ! 65.6 OF 58.3 / 56.8 OF 58.3 / 56.8 OF
Supply Air Ducts
Outside Air O
88 cfm Cooling Coil Supply Fan 59.0 / 57.1 OF
1600 cfm 47.8% R.H. ROOMS
78.8/64.6 °F 78.0 / 64.4 OF
o a... n:. n.._.U49 '
I_ EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 21 of 46 1
T
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Palley Residence 6/8/2005
SYSTEM NAME FLOOR AREA
HVAC #2 1,579
SYSTEM LOAD
24.0 of
311 :0
Outside Air
118 cfm
69.4 of
14.1 / 80.3 of
Outside Air
118 cfm
78.7/65.4 of
n-
,Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Sapply Air Ducts
111631TIN&YI&AWWOMER
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensiblel
Latent
I CFM
I Sensible
40,11 6,484
34,882
HS26-060/G40UH60C-110 (5) 45,905 6,707 89,400
Total Adjusted System Output 45,905 6,707 89,400
(Adjusted for Peak Design Conditions)
TME OF SYSTEM PEAK Aug 2 pm Jan 12 am
eam Tem1peratures at Time of Heating Peak)
108.10F 108.1 of
�w Supply Air Ducts
-Heating Coil Supply Fan 107.5 of
2000 cfm ROOMS
70.0 of
Return Air Ducts I
3.1 By EnergySoft User
80.8 / 66.4 of = 59.6 / 58.2 of
3665
Cooling Coil
Supply Fa
2000 cfm
59.6 / 58.2 of
-�j Supply Air Ducts
Fan
60.3/58.5oF
50.5% R.H. ROOMS
78.0/ 65.2 of
-t1
Return Air Ducts
Job Number:
of 46
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Palley Residence 6/8/2005
SYSTEM NAME FLOOR AREA
HVAC #3 870
ENGINEERING CHECKS 11SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
54,100
Total Output (Btuh)
54,100
Output (Btuh/sgft)
62.2
Cooling System
Output per System
36,000
Total Output (Btuh)
36,000
Total Output (Tons)
3.0
Total Output (Btuh/sqft)
41.4
Total Output (sgftrron)
290.0
Air System
CFM per System
1,200
Airflow (cfm)
1,200
Airflow (cfm/sqft)
1.38
Airflow (cfm/Ton)
400.0
Outside Air N
5.4
Outside Air (cfm/sqft)
0.08
Note: values above given at ARI conditions
AEATING SYSTEM PSYCHROMETRU
24.0 of
Outside Air
65 cfm
69.3 of
14.1 / 80.3 of
Outside Air
65 cfm
78.9/64.7 of
Total Room Loads
Return V' -anted Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensiblel
Latent
I CFM
I Sensible
1,164
23,575
2,237
420
17,196
0
1,179
860
0
0
65
2,479
1,503
65
3,194
0
0
1,179
860
28,41 3,74 22 110
HS26-036/G40UH36A-70X (3) 29,136 2,850 54,100
Total Adjusted System Output136 2,850 54,100
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
66.9 of ® 108.6 of
Heating Coil
Supply Fan
1200 cfm
108.6 of
Supply Air Ducts
108.0 of
ROOMS
70.0 of
�% Return Air Ducts 4
80.8 / 65.7 of . 58.3 / 56.9 of
Cooling Coil Supply Fa
1200 cfm
58.3 / 56.9 of
Supply Air Ducts
Fan
59.2 / 57.2 of
47.9% R.H. ROOMS
78.0 / 64.4 OF
h Return Air Ducts 'i
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:23of 46
HVAC SYSTEM HEATING AND COOLING LOADS-RHMMARY
PROJECT NAME DATE
The Palley Residence 6/8/2005
SYSTEM NAME FLOOR AREA
HVAC #4 1,076
ENGINEERING CHECKS 11SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
89,400
Total Output (Btuh)
89,400
Output (Btuh/sqft)
83.1
Cooling System
Output per System
58,500
Total Output (Btuh)
58,500
Total Output (Tons)
4.9
Total Output (Btuh/sgft)
54.4
Total Output (sgft/Ton)
220.7
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sgft)
1.86
Airflow (cfmfron)
410.3
Outside Air (%)
4.0
Outside Air (cfm/sqft)
0.07
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensible
Latent
CFM
I Sensible
39 547 5 49
HS26-060/C40UH60C-110 (5)' 46,226 5,725 89,400
Total Adjusted System Output 46,226 5,725 89,400
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatina Peak)
24.0°F 67.6°F 109.0°F
Outside Air
81 cfm
Heating Coil
69.5 OF
109.0 OF
Supply Air Ducts
Supply Fan 108.5 OF
2000 cfm ROOMS
70.0 OF
k Return Air Ducts `i
OOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time o
14.1 180.3 OF 80.2 / 65.6 OF 58.8 / 57.4 OF
Outside Air
81 cfm
Coolinc Coil Supply Fa
2000 cfm
78.8/64.9 °F
58.8 / 57.4 OF
Supply Air Ducts
Fan 59.6 / 57.7 OF
48.8% R.H. ROOMS
78.0 / 64.7 OF
h Return Air Ducts
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:24 of 46
f -
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
The Palley Residence 6/8/2005
SYSTEM NAME FLOOR AREA
HVAC #5 1,326
SYSTEM LOAD
:ATING SYSTEM
24.0 of
Outside Air
99 cfm
69.3 of
:DOLING SYSTEM Pc
14.1 / 80.3 of
Outside Air
99 cfm
78.9/65.2 of
,0c
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
11COILHTG.PEAK
CFM
ISensiblel
Latent
I CFM
I Sensible
45,4381 5,824 35,753
HS26-060/C40UH60C-110 (5) 46,242 6,054 89,400
TotallAdjusted System Output 46,242 6,054 89,400
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
,eam Temperatures at Time of Heating Peak)
108.5 of 108.5 of
Heating Coil
O Supply Air Ducts
W,
Supply Fan 107.9 of
2000 cfm ROOMS
70.0 of
Return Air Ducts ` I
80.6 / 66.0 of 59.2 / 57.8 of
Cooling Coil Supply Fa
2000 cfm
59.2 / 57.8 of
Supply Air Ducts
Fan
60.1 / 58.1 of
49.6% R.H. ROOMS
78.0 / 64.9 of
h Return Air Ducts
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 25 of 46
]ROOM LOAD SUMMARY
PROJECT NAME
The Palley Residence
DATE
6/8/2005
SYSTEM NAME
HVAC #1
FLOOR AREA
1,170
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
ZONE #1
Master Suite
1
1,279
26,200
3,010
1,279
26,200
3,010
344
14,280
PAGE TOTAL 1 1,279 26,200 3,010 344 14,280
TOTAL 1 • 1,279 26,200 3,010 344 14,280
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:26.of 46
%~%RA I r% w r% C%l Iwaww w w.
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:27 of 46
ROOM LOAD SUMMARY
PROJECT NAME
The Palley Residence
DATE
6/8/2005
SYSTEM NAME
HVAC #3
FLOOR AREA
870
ROOM LOAD. SUMMARY
ROOM
COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME'
ROOM NAME
Mult:
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
ZONE #3
Guest Suite/Gallery/Laundry
1
1,164
23,575
2,237
1,164
23,575
2,237
420
17,196
r
PAGE TOTAL 1 1,164 23,575 2,237 420 17,196
.. TOTAL 1 1,164 23,575 2,237 420 17,196
q
EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 28 of 46
r
ROOM LOAD SUMMARY
PROJECT NAME
The Palley Residence
DATE
6/8/2005
SYSTEM NAME
HVAC #4
FLOOR AREA
1,076
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM i SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
ZONE #4
Reception/Entry
1
116651
j
33,154
3,706
1,665
33,154
3,706
570
23,663
PAGE TOTAL 1 1,665 33,154 3,706 570 23,663
TOTAL 1,665 33,154 3,7061F 570 23,663
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 29 of 46
ROOM' LOAD SUMMARY
PROJECT NAME
The Palley Residence
DATE
6/8/2005
SYSTEM NAME
HVAC #5
FLOOR AREA
1,326
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
ZONE #5
Kitchen/Dining/Family
1
1,958
37,869
3,699
1,958
37,869
3,699
687
28,077
PAGE TOTAL 1 1,9581 37,869 3,699 687 28,077
TOTAL 1 1,958 37,869 3,699 687 28,077
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:30 of 46
ROOMHEATING PEAK LOADS ,
Project Title Date
The Palley Residence 618/2005
Room Information Desicin Conditions
Room Name Master suite Time of Peak Jan 12 am
Floor Area 1,-,70 Outdoor Dry ;Bulb Temperature, 24°F
Indoor Dry Bulb Temperature 70`0F
Conduction Ares U -Value AT OF Btu/hr
x
x
x
X
X
x
x
x
X
x
xX
x
X
x
x
X
X
x
X
x
X
X
X
x
x
X
x
X
X
X
X
X
X
x
X
x
x
X
x
0.0255
X
X
' X
x'
x
x46.0
x
X
x
X
x
X
x
X
x
X
X
x
X
x
X
X
X
X
X
x
X
x
x
x
x
X
x
x
X
x
X
x
46.0
=
=
=
=
=
=
—
c
—
—
=
=
=
=
=
=
=
=
=
=
—
=
=
=
_
=
_
=
=
—
=
=
=
=
=
=
=
1,366
0.6800
46.0
188
0.0566
46.0
3,295
0.3900
46.0
2,153
0.3800
46.0
1,689
0.3500
1,230
f
'
Items shown with an asterisk ('r) denote conduction through an interior surface to anther room. .+ Page Total: 9 920
Infiltration: 1.001X 1.080 x 1 170 X 9.00 x 0.50 R / 60] X 46 = 4 360
chedule Air Sensible Area Ceiling Height ACH ILT
Fraction
S
TOTAL HOURLY HEAT LOSS FOR ROOM 14,280
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 31 of 46
r
Project Title Date '
The Palley Residence 6/8/2005
Room Information Design Conditions
Room Name Boys & Girls Suite/Media/Den Time of Peak Jan 12 am
Floor Area 1,E79 Outdoor Dry Bulb Temperature 24OF
Indoor Dry,Bulb Temperature 70F
Conduction Area U -Value AT of Btu/hr
-
600.0
x
X
, x°
, x
X
x
x.-
X
x
x
X..
x
x
xX
x
x
x
x
XX
x
X
x
x
x
XX
x
X
X
X
X
x
x
x
X.
x
t
X
x
x
x
0.1730
X .
X
X
X
X
x
X
X
X
X
x
X
x
x
x
X
x
x
X
X
X
X
x
x
x
X
x
x
x
x
x
x
x
X
x.
X
0.0
=
=
=
=
=
=
=
=
=
=
=
—
=
_
=
=
_
=
—
—
_
—
=
_
=
0
975.0
0.0255
46.0
1,144
4.0
0.6800
46.0
125
,406.3
0.0566
46.0
3,663
149:2
0.3900
46.0
2.677
150.9
0.3800
46.0
2,638
20.0
0.3872
46.0
356
58.6
0.3500
46.0
943
perimeter= 198,0
45.5
9,009
t
-
!
Items shown with an asterisk (•rr) denote conduction through an interior surface to arother room. Page Total: 20 555
Infiltration: -Schedule
x 1.080 x Y 579 X 9.00 x 0.50 / 60] x 46 = 5 881
Air Sensible Area Ceiling Height ACH &T
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 26,436
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 32 of 46
.r�
ROOM HEATING PEAK LOADS
Project Title Date
The Palley Residence 6/8/2005
Room Information Design Conditions
Room Name Guest Suite/Gallery/Laundry Time of Peak Jan 12 am
Floor Area 870 Outdoor Dry Bulb Temperature 24 OF
Indoor Dry Bulb Temperature 700F
Conduction Area U -Value AT of Btu/hr
Items shown with an asterisk (') denote conduction through an interior surface to an room. Page Total 13 956
Infiltration: 1 1.00 x 1.080 x 870 x 9.00 x 0.50 / 60] x 46 = 3 240
Schedule AlrSensible Area Ceiling Height ACH� DT
• Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 17,196
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 33 of 46
570.5
X
x
x `
x
• x
x
x
x
x
x
X
x
x
x
x
x
x
x
x
x
X
x.,
x
x
x
X
x
x
X
x
X
x
x..
x
X
X
xx
x
x
0.1730
x
x
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
X
x
x
x
x
x
x
X
x
X
x
x
x
x
x
x
x
X:
x
x
0.0
=
=
=
=
=
—
=
=
=
=
=
=
=
=
=
=
-
=
=
=
_
=
—
=
=
=
=
=
=
=
=
—
—
=
_
—
—
=
0
299.5
0.0255•
46.0
351
802.6
0.0566
46.0
2,091
.101.2
0.3900
46.0
1,816
227.2
0.3600
46.0
3,658
15.0
0.3800
46.0
262
erirrneter = 127.0
45.5
5,778
r.
F
w
Items shown with an asterisk (') denote conduction through an interior surface to an room. Page Total 13 956
Infiltration: 1 1.00 x 1.080 x 870 x 9.00 x 0.50 / 60] x 46 = 3 240
Schedule AlrSensible Area Ceiling Height ACH� DT
• Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 17,196
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 33 of 46
` ROOM HEATING PEAK LOADS
, r
Project Title Date
The Palley Residence 6/8/2005
Room Information:, Design Conditions
Room Name a Reception/Ertry Time of Peak Jan 12 am
Floor Area 1,076 Outdoor Dry Bulb Temperature 24OF
Indoor Dry Bulb Temperature 70'F
Conduction Area U -Value AT OF Btu/hr
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 17,429
Infiltration: 1.00 x 1.080 x 1 076 x 14.00 x 0.50 / 60] x 46 ( = 6234
-Schedule Air Sensible Area Ceiling Height ACH OT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 23,663
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 34 of 46
1
1,076.0
X
x
x
X
x .
x
x
x
x
x
x
X
x
X.
x
x
x
X
x
X
x
x
X
X.
x
x
x
X
X
X
x
x
X
x
x
"x
x
X
x
0.0255
X
x
x
x
X
x
x
x
x
x
x
x
x
x
x
x
X'
X
x
X
x
x
X
x
x
x
x
X
x
x
x
x
x
x
x
x
X
x
x
46.0
=
=
=
=
=
=
=
=
=
-
—
=
=
=
=
=
_
=
=
=
—
=
_
=
=
—
=
=
=
=
—
=
=
—
_
_
=
1,262
1,252.6
0.0566
46.0
3,263
306.0
0.3900
46.0
5,490
121.4
0.3500
46.0
1,955,
perimeter =120.0
45.5
5,460
r
Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 17,429
Infiltration: 1.00 x 1.080 x 1 076 x 14.00 x 0.50 / 60] x 46 ( = 6234
-Schedule Air Sensible Area Ceiling Height ACH OT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 23,663
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 34 of 46
1
Project Title Date
The Palle Residence 6/8/2005.
Room Information Desi n Conditions
Room Name Kitchen/Dining/Family Time of Peak Jan 12 am
Floor Area 1,326 Outdoor Dry Bulb Temperature 24 OF
Indoor Dry Bulb Temperature 70'F
Conduction ' Area U -Value AT of Btu/hr
•
Items shown with an asterisk (') denote conduction through an interior surface to amther room. Page Total: 22 452
Infiltration: [ 1.00 x 1.080 x 1 326 x F 10.25 x 0.50 / 60] x 46 = 5 625
Schedule AikSensible Area Ceiling Height ACH OT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 28,077
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 35 of 46
1326.0
X
x
x
x
x
x
x
x
x
x
X
X
x
x
x -
`x
x
x
x
x
x
X
x
x
x
x
x
x
x
xx
x
x
x
x
x
x
xx
x,
x
0.0255
x
X
X
X
x
X
x
x
x
x
x
x
X
x
x
x
x
x
x
x
X
X
X
x
X
X
x
X
x
x.
x
x
X
X
X
x
x
46.0
=
=
=
=
=
=
=
=
=
=
=
—
=
=
=
-
=
=
=
—
=
=
_
=
_
=
=
=
=
=
_
=
=
=
=
=
=
=
=
1,556
496.4
0.0566
46.0
3,898
77.4
0.3800
46.0
1,353
379.2
0.3500
46.0
6,105
55.0
0.3900
46.0
987
perimeter = 188.0
45.5
8,554
'
v
Items shown with an asterisk (') denote conduction through an interior surface to amther room. Page Total: 22 452
Infiltration: [ 1.00 x 1.080 x 1 326 x F 10.25 x 0.50 / 60] x 46 = 5 625
Schedule AikSensible Area Ceiling Height ACH OT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 28,077
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 35 of 46
mac°
RESIDENTIAL ROOM COOLING LOAD SUMMARY
The.Palley Residence 6/8/2005
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Master Suite
780E
115°F
37°F
Conduction Area U -Value DETD 1 Btu/hr
X
X
X
X
X
X
56.0
=
=
=
=
=
=
1,663
37.0
151
35.6
2,550
37.0
1,732
37.0
1.358
37.0
989
X
X
X
1. Design Equivalent Temperature Difference (DETD) Page Total 8,443
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
4) Solatube Skylights Q
(Skylight) -
F_mchDr_(10)
(North)
CsmntWdw T
(North)
FxdGlsWdw U
(North)
CsmntWdw (R)
(North)
CsmntWdw R
(North)
CsmntWdw S
(North)`
FxdGlsWdw BB
(East)
CsmntWdw (S)
(South)
CsmntWdw S
South
( 0.0
x
X
X
x
X
X
x
x
X
x
1
+
+
+
+
+
+
+
+
+
+
6.0
X
x
X
X
X
X
x
X
X
x
152)
X
X
x
X
x
) x
0.632
=
=
=
=
=
=
=
=
=
=
577
{ 0.0
;1
40.0
15)x
0.312
187
( 0.0
1
25.0
15)
0.334
125
( 0.0
1
25.0
15)x
0.423
159
{ 0.0
1
11.3
15)x
0.334
57
( 0.0
1
11.3
15)X
0.334
57
( 0.0
1
7.0
15)
0.334
35
( 0.0
1
30.4
73)
0.423
939
( 0.0
1
7.0
32)
0.334
75
( 0.0
1
7.0
32
0.334
75
Sched.
Page Total 2 284
Internal'Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 x 1,170 X 0.500 Watts/sgft x 3.413 Btuh[Watt = 1.997
Occupants 1.00 X 1,170 X 250 Btuh/occ. / 200 sgft/occ. = 1,463
Receptacle 1.00 x 1,170 X 1.500 Wafts/sgft x 3.413 Btuh/Waft = 5,992
Process X1.000x 1,170 X 0.000 Watts/sgft x 3.41BtuhhfWatt = 0
Infiltration: E -oo x I 1.0>�OJ x 17_0 x E . 9 o E
om E37J x / 60] =50
Schedule Air Sensible Area Ailing Height ACH DT
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 26200
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occu ants1.00 x 1 170 x 200 Btuh/occ. / 200 sgft/occ. = 1 170
Receptacle 1.00 x 1170 x 0.000 Watts/sqft X 3.41 Btuh/Waft = o
Process 1.00 x 1 170 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = 0
Infiltration: I 1.00 x L 4 840 • x 1 17 x 9.00 x 0.50 / 60] 0.00433 =1 839
Schedule Air Latent Area Ceiling Height - ACH pyy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,010
EnergyPro 3.1 By EnergySoft User Number: 1 3665 Job Number: Page: 36 of 46
RESIDENTIAL ROOM COOLING LOAD SUMMARY
The Palley Residence 6/8/2005
Project Title Date
Room Name Master Suite
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature: '
Design Temperature Difference:
78°F
115°F
370E
Conduction Area U -Value DETD Btu/hr
t. Design Equivalent Temperature Difference (DETD) Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
CsmntWdw (0 (South) ( 0.0 X 1 + 20.0 x 32)X 0.334 = 214
Ftd.G.ISW-dw. (Y_) (South) ( 0.0 X 1 +' 10.5 x 32) x 0.423 = 142
FxdGlsWdw V _ South ( 0.0 X 1 + 10.5 x 32)X 0.423 = 142
CsmntWdw Q (West) ( 0.0 X 1 + 8.0 X 73) x 0.334 = 195
FrnchDr (10) (West) ( 0.0 x 1 + 40.0 X 73)x 0.312 = 910
FrnchDr (10) (West) ( 0.0 x 1 + 40.0 x 73) X 0.312 = 910
( x + x )x =
( x + x )x =
( x + x )X =
Sched.
Page Total 2,513
Internal Gain Frac. Area Heat Gain - Btu/hr
Lights 1.00 x 1,170 X 0.500 Watts/sqft x 3.41 Btuh/Waft = 1,997
Occupants 1.00 X 1,170 X 250 Btuh/OCC. / 200 sgft/occ. = 1,463
Receptacle 1.00 x 1,170 X 1.500 Wafts/sgft x 3.413 Btuh/VVaft = 5,992
Process 1.00 X 1,170 x 0.000 Wafts/sgft X 3.41 Btuh/Waft = 0
Infiltration: [ . QO x OBOii x 1,]Z0 x 9_Qo x 0 50 / 60] = 3.50
Schedule Air Sensible Area Ceiling Height ACH LST
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 26 200
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 1 170 x 200 Btuh/occ. / 200 sgft/occ.• = 1 170
Receptacle 1.00 x 1 no x 0.000 Watts/sqft x 3.413 Btuh/Waft = o
Process 1.00 x 1 170 x 0.000 Wafts/sgft x 3.41 'Btuh/Waft = o
Infiltration: C too x 4 840 x 1 17 X Height
X 60] 0.00433 = 1 839
Schedule Air Latent Area ' Ceiling Height ACH. �yy
Fraction .
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,010
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 37 of 46
RESIDENTIAL ROOM COOLING LOAD SUMMARY
The Palley Residence ' 6/8/2005
Project Title Date
Room Name Boys & Girls Suite/Media/Den
Design Indoor Dry Bulb Temperature: 780F
Design Outdoor Dry Bulb Temperature: 115 0F
Design Temperature Difference: 370F
Conduction Area U -Value DETD 1 Btu/hr
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
'Shaded
Solar Gain Orientation Area SGF
) Solatube Skylights U
Sk li ht)
Rdstolite_S.kylig6L(AA)
(Skylight)
FrnchDr 10
(North)
FrnchDr 10
(North)
CsmntWdw (Y)
(North)
FxdGlsWdw X
(North)
FrnchDr 11
East
FxdGlsWdw DD
East
FxdGISWdW DD
(East)
CsmntWdw O
South
( 0.0
X
X
x
x
X
X
x
x
X
X
1 +
1 +
1 +
1 +
1 +
1 +
15 +
1 +
1 +
1 +
( 0.0
( 0.0
( 0.0
( 0.0
( 0.0
( 0.0
( 0.0
( 0.0
( 0.0
x
x
x
x
x
x
x
X
x
0.0
=
=
=
=
=
=
=
=
=
0
56.0
1,392
37.0
101
35.6
2,835
37.0
2,153
37.0
2,122
35.6
276
37.0
759
187
40.0
Page Total 1 9,637
Unshaded
Area
X
X .
X
x
X
X
x
X
x
X1
SGF
X
X
X
X
x
X
SC
=
=
=
=
=
=
=
=
-
=1
Btu/hr
4.0
152)
0.632
384
0.0
152)x
0.494
0
40.0
15)x
0.312
187
40.0
15)x
0.312
187
11.3
15)x
0.334
57
20.0
15)
0.423
127
34.6
73)
0.312
787
19.3
73)
0.423
596
19.3
73)
0.423
596
8.0
32)
1 0.334
85
Sched.
Page Total 3 007
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 x 1,579 x 0.500 Watts/sqft x 3.41 Btuh/Waft = 2,695
Occupants 1.00 X 1,579 X 250 Btuh/OCC. / 200 sqft/occ. = 1,974
Receptacle 1.00 x 1,579 x 1.500 Watts/sqft x 3.413 Btuh/Waft = 8,084
Process 1.00 x 1,579 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0
Infiltration:0o x =Iq780 x E=u'x 9.99 x , - 0 50 / 60] =37J = no
Schedule Air Sensible Area Ceilinat Height ACH z -\T
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 32,356
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 1,579 X 200 Btuh/occ. / 200 sgft/occ. = 1 579
Receptacle 1.00 X 1,579 X 0.000 Watts/sqft X 3.41 Btuh/Watt = 0
Process 1.00 x 1,579 X 0.000 Watts/sgft X 3.41 Btuh[Watt = 0
Infiltration: 1.00 Ix 4 840 x 1 57 x eigh X 60] 0.00433 = 2 481
chedule Air Latent Area CeilinglHlght ACH pyy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,060
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 38 of 46
V
RESIDENTIAL ROOM COOLING LOAD SUMMARY
The Palley Residence 6/8/2005
Project Title Date
Room Name „ Boys & Girls Suite/Media/Den
Design Indoor Dry Bulb Temperature: 780F
0
Design Outdoor Dry Bulb Temperature: 115 F
Design Temperature Difference: 370F
Conduction Area U -Value DETD 1 Btu/hr
X =
X -
X =
X =
X =
X =
X =
X =
X
1. Design Equivalent Temperature Difference (DETD) Page Total
01
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area . SGF Area SGF SC Btu/hr
CsmntWdw CC
_ South
Csmn
(South)
CsmntWdw CC
(South)
CsmntWdw W
(South)
FrnchDr (11)
(West)
CsmntWdw DD
(West)
CsmntWdw DD
West
32
0.334
294
( 0.0
1
27.5
( 0.0,x
X
x
x
x
X
x
x
x
x
1
+
+
+
+
+
+
+
+
+
+
27.5
x
x
x
x
X
X
x
x
X
x
32)
x
) x
X
x
x
)X
)x
)x
0.334
=
=
=
=
=
=
=
=
=
=
294
( 0.0
- 1
27.5
32
0.334
294
( 0.0
1
27.5
32)
0.334
294
( 0.0
1
10.5
32)
0.334
112
( 27.2
1
7.4
73)
0.312
295
( 0.0
1
19.3
73)X,
" 0.334
471
( 0.0
1
19.3
73)X
0.334
471
(
(
('
Sched. Page Total 2.23
Internal Gain Frac. Area Hsat Gain Btu/hr
Lights 1.00 x 1,579 X 0.500 Watts/sgft x 3.41 Btuh[Waft = 2,695
Occupants 1.00 X 1,579 X 250 Btuhloco. / 200 sgft/occ. = 1974
Receptacle 1.00 x 1,579 x 1.500 Wafts/sgft x 3.413 BtuhlWaft = 8,084
Process ��1.00��x 1,579 x 00.000 Watts/sqft x 3.41 Btuh/Watt = 0
Infiltration: [ pp x ( 1 -W -o x 5Z9 x I 999 x 050 / 60] �37J = Z30
Schedule Air Sensible Area Ceiling Height ACH LST
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 32,35J
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 1 579 x 200 Btuhloco. / 200 sgft/occ. = 1 579
Receptacle 1.00 x 1 579 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0
Process 1.00 x 1 679 X 0.000 Watts/sgft x 3.41 Btuh/Watt = 0
Infiltration: [ 1. 01 x 4840 x 1 57 x 9.00 x 0.50 / 60]; 0.00433 =2 481
Schedule Air Latent Area Ceiling ieight ACH pyy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,060
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 39 of 46
RESIDENTIAL ROOM COOLING LOAD SUMMARY
The Palley Residence 6/8/2005
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Guest Suite/Gallery/Laundry
780F
115°F
37°F
Conduction Area U -Value DETDBtu/hr
X.
0.0
=
0
x
56.0
=
428
x
35.6
=
1,618
x
37.0
=
1,460
x
37.0
=
2 942
x
37.0
=
211
x
x
X
1. Design Equivalent Temperature Difference (DETD) Page Total 6 659
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain. Orientation Area SGF Area SGF Sc Btu/hr
FrnchDr 10
North
Exd.GIs.WNdw_(P_)
FxdGlsWdw G
(North)
(East)
FxdGIsWdW G
East
FrnchDr (12)
CsmntWdw (Q
(East)
(South)
FrnchDr 3
South
CsmntWdw S
FxdGlsWdw (1)
(West)
est)
FxdGlsWdw H
est
( 0.0X1
X
x
x
x
X
x
x
X
x
+
+
+
+
+
+
+
+
+
+
40.0x"
X
x
X
X
X
X
x
X
x
15)x
) X
X
x
X
X
X
x
x
0.312=
=
=
=
=
=
=
=
_
=
187
( 0.0
1
30.0
15
0.423
190
( 0.0
1
40.0
73)
0.423
1,235
( 0.0
1
40.0
73)x
0.423
1,235
( 27.2
1
7.4
73)
0.312
295
( 0.0
1
8.0
32)
0.334
85
( 0.0
15
26.6
32)
0.312
265
( 0.0
1
7.0
73)
0.334
171
( 0.0
1
18.6
73)
0.423
574
( 0.0
1
40.0
73)
0.423
1,235
Sched. '
Page Total 5 474
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 870 x 0.500 Wafts/sqft x 3.41 Btuh[Watt = 1,485
Occti pants 1.00 X 870 X 250 Btuh/OCC. / 200 sgft/occ. = 1,088
Receptacle 1.00 x 870 X 1.500 Watts/sqft x 3.413 Btuh/Waft = 4,454
Process 1.00 x 870 x 0.000 Wafts/sqft x 3.413 Btuh/Waft = 0
Infiltration: X[:::17-080 x 87-0 x9...00 x0 ao / 60]37 = 606
Schedule Air Sensible Area Ceiling Height ACH LST
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 23,57J
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 870 x 200 Btuh/occ. / 200 sgft/occ. = 870
Receptacle 1.00 X 870 x 0.000 Wafts/sgft X 3.41 Btuh/Waft = 0
Process 1.00 x 870 x 0.000 Watts/sgft x 3.413 Btuh/Waft = 0
Infiltration:[ 1.00 x 4840 x 87 x 9.00 x 0.50 / 60] 0.00433 = 1 367
Schedule Air Latent Area Ceiling Height ACH LWy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,237
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:40 of 46
T `
RESIDENTIAL ROOM COOLING LOAD SUMMARY
The Palley Residence 6/8/2005
Project Title + Date
Room Name Guest Suite/Gallery/Laundry
o
Design Indoor Dry Bulb Temperature: f 780F
Design Outdoor Dry Bulb Temperature: t 115 F
Design Temperature Difference: 37°F
Conduction
U -Value DETD 1 Btu/hr
•' X '
X
X
X
X
X
X
X
X
X —
X _
X —
X =
X =
X =
X =
X =
X —
1. Design Equivalent Temperature Difference (DETD) Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room. s
Shaded Unshaded
Solar Gain I • • Orientation " . Area SGF Area SGF SC Btu/hr
( 0.0
x
x
X
x
x
x
x+
x
X
X
1
+
+
+
+
+
+
+
+
+
18.6
x
x
x'
x
x
x
X
X
x
X
73
)X
)X
)x
)x
)X
)X
)X
)X
)X
)X
0.423
=
=
=
=
=
=
_
=
=
=
574
'
( 0.0
1
40.0
73
0.423
1,235
(
(
(
(
(
( r
(
(
-
Sched.
Page Total 1 810
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 X 870 X 0.500 Watts/sgft• x 3.412 BtuhlWaft = 1,485
Occupants 1.00 X 870 x 250 13tuh/occ. / 200 sgft/occ. = 1,088
Receptacle 1.00 x 870 X 1.500 Wafts/sqft x 3.413 Btuh/Waft = 4,454
Process 1.00.x 1870 x 0.000 Watts/sgft x 3.412 Btuh/Watt = 0
Infiltration: 00 x [=Q-0] x -s7o x 9_Qo x 050 / 60] L_3Z _ 2,_6Q6
Schedule Air Sensible Area Ceiling Height ' ACH LST
ITOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 23,5751
Sched. -
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 870 x 200 Btuh/occ. / 200 sgft/occ. = 870
Rece tacle 1.00 x 870 x - -0.000 Wafts/sgft x 3.41 Btuh/Watt = o
Process 1.00 x 870 x 0.000 Wafts/sqft x 3.41 BtuhMatt = o
Infiltration:[ 1:00 x 4 840 x 87 x 9.00 x 0.50 / 60] 0.00433 . = 1 367
Schedule Air Latent Area Ceiling Height ACH QW
Fraction j
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,237
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:41 of 46
r� RESIDENTIAL ROOM COOLING LOAD SUMMARY
The Palley Residence 6/8/2005
Project Title Date
Room Name Reception/Entry
Design Indoor Dry Bulb Temperature: 780F
0
Design Outdoor Dry Bulb Temperature: 115 F
Design Temperature Difference: 370F
Conduction Area U -Value DETD 1 Btu/hr
X
X
X
X
X
X
X
X
X
56.0
=
=
=
=
=
=
=
=
=
1,537
35.6
2,525
37.0
4,416
37.0
1,572'
FrnchQr 2
(East)
FrnchDr 2
(South)
FxdGlsWdw C Abv.
West
FrnchDr 2
(West)
FXdGISWdW B
West
1. Design Equivalent Temperature Difference (DETD) Page Total 1 10,0491
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation - Area SGF Area SGF Sc Btu/hr
FrnchDr 2
North
Exd.GlsWdw. __(C Ab_v_)
(East)
FrnchDr 2
_ East
SwngGlsEntryDr 1
(East)
FxdGlsWdw (C Abv.)
(East)
FrnchQr 2
(East)
FrnchDr 2
(South)
FxdGlsWdw C Abv.
West
FrnchDr 2
(West)
FXdGISWdW B
West
0.0
x
x
x
x
X
X
X
x
x
x
1
+
+
+
+
+
+
+
+
+
42.5
X
x
x
X
X
x
X
x
x
x
15
) X
) x
X
x
x
X
X
) x
X
0.312
=
=
=
=
=
=
=
=
=
=
199
( 0.0
141+
3.8
73
0.423
117
( 0.0
1
42.5
73)
0.312
967
( 0.0
1
51.0
73)
0.312
1,160
( 0.0
V
3.8
73)
0.423
117
( 0.0
1
42.5
73)
0.312
967
( 0.0
1
42.5
32)
0.312
424
( 0.0
15
3.8
73)X
0.423
117
( 0.0
1
42.5
7
0.312
967
( 0.0
1
25.6
73)
0.423
791
Page Total 5,827
Sched.
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 x 1,076 X 0.500 Watts/sqft x 3.41 BtuhNVaft = 1,836
Occupants 1.00 X '1,076 X 250 Btuh/oCC. / 200 Sgft/oCC. = 1,345
Receptacle 1.00 x 1,076 x 1.500 Watts/sgft x 3.413 BtuhlWaft = 5,509
Process �1.000xx 1,076 x 0.00000 Watts/sqft x 3.41 BtuhNVatt = 0
Infiltration: 1,.Q0 x I �_Q8D1 x t QZ6 X f L4,Xop x • 0_�0 / 60] E=_3 = 5 0
Schedule Air Sensible Area Ceiling Height ACH nsT ,
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 33154
Sched. I '
Latent Gairi Frac. Area Heat Gain Btu/hr
Occuants 1.00 x 1 076 x 2001 Btuh/occ. / 200 sgft/occ. = 1 076
Receptacle 1.00 .X 1 076 X 0.000 Watts/sgft X 3.41 Btuh/Watt = 0
Process 1.00 x 1 076 X 0.000 Wafts/sgft X 3.41 Btuh/Waft = 0
Infiltration: 1.00 x 4 840 X 1 076 X Heigh X 60]' 0.00433 = 2 630
chedule Air Latent Area 'Ceiling Height ACH pyy
Fraction r
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,706
EnergyPro 3.1' By EnergySoft User Number: 3665 Job Number. Page:42 of 46
M
RESIDENTIAL ROOM COOLING LOAD SUMMARY
The Palley Residence 6/8/2005
Project Title Date
Room Name Reception/Entry
Design Indoor Dry Bulb Temperature: 780F
0
Design Outdoor Dry Bulb Temperature: 115 F
Design Temperature Difference: 370F
Conduction Area U -Value DETD 1 Btu/hr
1. Design Equivalent Temperature Difference (DETD) Page Total
01
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC -Btu/hr
( 0.0
X
'x
x
X
x
X
x
X
x
X
1
+
+
+
+
+
+
+
+
+
+
55.0
x
x
x
x
x
x
X
X
X.
X
73
) X
) x
X
x
)x
)x
)x
)x
)X
)X
0.423
=
=
=
=
=
=
=
=
=
=
1,698
( 0.0
1
25.6
73
0.423
791
( 0.0
1
3.8
73)
0.423
117
( 0.0
' 1
42.5
73)
0.312
967
(
(
(
(
(
I
Sched.
Page Total 3,573
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 x 1,076 x 0.500 Watts/sqft x 3.413 Btuh/Waft ',= 1,836
Occupants 1.00 X 1,076 X 250 Btuh/occ. / 200 sgft/occ. = 1,345
Receptacle 1.00 x 1,076 x 1.500 Wafts/sqft x 3.413 Btuh/Waft = 5,509
Process 1.00 x 1,076 x 0.000 Wafts/sqft x 3.413 BtuhNVatt = ��0
Infiltration: 1..00 x 080 x 1 076 x 14.00 ' 37 I ��x a50 / 60] 5,0144
Schedule Air Sensible Area Ceiling Height ACH nsT
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 33154
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 1 076 x 200 Btuh/occ. / 200 sgft/occ. = 1 076
Receptacle 1.00 X 1 076 x 0.000 Watts/sgft X 3.41 Btuh/Waft = 0
Process f 1.00 X 1 076 X 0.000'W* afts/sqft X 3.413 Btuh/Waft = 0
Infiltration: II 1.00 x L 4,8401 x 1 076 x 14.00 ' x 0.50 / 60] 0.00433 = 2 630
chedule AlrLatent Area Ceiling Height ACH pyy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,706
EnergyP- 3.1 By EnergySoft User Number: 3665 Job Number: Page: 43 of 46
RESIDENTIAL ROOM COOLING LOAD SUMMARY
The Palley Residence 6/8/2005
Project Title Date
Room Name Kitchen/Dining/Family
Design Indoor Dry Bulb Temperature: 780F
0
Design Outdoor Dry Bulb Temperature: 115 F
Design Temperature Difference: 370F
c
Conduction Area+ U -Value DETD 1 Btu/hr
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
X
North
56.0
=
1,894
X
CsmntWdw L
35.6
=
3,016
X
(North)
37.0
=
1,088
X
FxdGISWdW G
37.0
=
4,911
X
37.0
=
794
Page Total 1 11.703
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
CsmntWdw K
North
-xdGjs.WA.w-(J)
(North)
CsmntWdw K
(North)
CsmntWdw L
(North)
CsmntWdw (L)
(North)
CsmntWdw M
(North)
CsmntWdw N
(East)
FxdGlsWdw G
(East)
FxdGISWdW G
(East) .
FXdGISWdw 1
East
( 0.0
X
1
+
8.2
X
15)X
0.334
=
41
( 0.0x
1
+
18.0X
15)X
0.423=
114
( 0.0
x
15
+
8.2
x
15)X
0.334
=
41
( 0.0
x
1
+
13.5
X
15)x
0.334
=
68
( 0.0X
1
+
13.5X
k15)x
0.334=
68
( . 0.0
X
1
+
12.0
x
15)
X
0.334
=
60
( 0.0
x
1
+
8.0
x
73)
X
0.334
=
195
( 0.0
x1
+
40.0
X
73)x
0.423
=
1,235
( 0.0
X
15
+
40.0
X
73)
X
0.423
='
1,235
( 0.0
X
1
+
18.6
X
73)
x
0.423
=
574
Sched.'
Page Total 3,632
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 x 1,326 X 0.500 Watts/sgft x 3.41 Btuh/Watt = 2,263
Occupants 1.00 X 1,326 X 250 Btuh/OCC. / 200 sgft/occ. = 1,658
Receptacle 1.00 x 1,326 x 1.500 Watts/sqft x 3.413 Btuh/VVatt = 6,788
Process �1.000xx 1,326 x X0.00000 Watts/sgft x 3.41BtBtuhh Watt = 0
Infiltration: 00 x I 1 8O x E,=3261 x E1.025J x 0 0 / 60] �37J = ,524
Schedule Air Sensible Area Ceiling Height ACH DT
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 37,8691
Sched.
Latent Gain Frac. Area HeElt Gain Btu/hr
OccupantsL=111000
x 1 326 x 200 Btuh/occ. / 200 sqft/occ. = 1 326
Receptacle x 1 326 x 0.000 Watts/sqft X 3.41 BtuhNVatt = 0
Process r x 1 326 x 0.000 Watts/sqft x 3.41 BtuhMatt = o
Infiltration: I 1.00 x 4,8401 x 1 32 x 0.25 x 0.50 /601 0.00433 = 2 373
Schedule Air Latent Area Ceiling Freight ACH �yy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,699
EnergyPro -3.1 By EnergySoft User Number: 3665 Job Number: Page: 44 of 46
RESIDENTIAL ROOM COOLING LOAD SUMMARY
The Palley Residence 6/8/2005
Project Title Date
Room Name Kitchen/Dining/Family
Design Indoor Dry Bulb Temperature:. 780F
0
Design Outdoor Dry Bulb Temperature.,115 F
Design Temperature Difference: 370F
Conduction Area, U -Value DETD 1 Btu/hr
1. Design Equivalent Temperature Difference (DETD) Page Total
01
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded. Unshaded
Solar Gain Orientation Area SGF Area SGF Sc Btu/hr
FXdGIsWdw (D
(South)
F-cdG.Is..Wdw_(.
(South)
FrnchDr 3
(South)
FxdGISWdW F
(South)
FrnchDr (3)
(South)
CsmntWdw S
(South)
CsmntWdw S
(South)
FxdGIsWdW G
(West)
FxdGlsWdw G
(West)
FxdGlsWdw 1
est
( 0.0
x
x
X
X
x
x
x
X
X
x
1
+
+
+
+
+
+
+
+
+
+
19.3
X
x
X
x
x
x
x
X
X
x
32
) X
) x
)x
x
x
) x
0.423
=
=
=
=
=
=
=
=
=
=
261
( 0.0
1
27.5
32
0.423
372
( 0.0
1
27.5
32
0.312
274
( 0.0
1
40.0
32)
0.423
541
( 0.0
1
27.5
32)
0.312
274
( 0.0
1
7.0
32)X
0.334
75
( 0.0
1
7.0
32)X
0.334
75
( 0.0
1
40.0
73)X
0.423
1,235
( 0.0
1
40.0
73)x
0.423
1,235
( 0.0
1
18.6
73
0.423
574
Sched. .
Page Total 4 918
Internal Gain Frac., Area, Heat Gain Btu/hr
Lights 1.00 x 1,326 X 0.500 Watts/sgft x 3.41 Btuh/Watt = 2,263
Occupants 1.00 X 1,326 X 250 Btuh/OCC. / 200 sgft/occ. = 1,658
Receptacle 1.00 x 1,326 x 1.500 Waftslsgft• x 3.413 Btuh/Watt = 6,788
Process 1.00 x 1,326 x 0.000 Wafts/sgft x 3.413�Btuh/Watt = 0
Infiltration: [ 1_QO x 1_Q80 x w x o.25 x 0..50 / 60] t 3JJ = 4,524
Schedule Air Sensible Area Ceiling Height ACH LST
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 37,8691
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 1 326 x 200 Btuh/OCC. / 200 sgft/occ. = 1 326
Receptacle 1.00 x 1 326 x 0.000 Wafts/sqft x 3.41 BtuhlWaft = 0
Process 1100 x 1 326 x 0.000 Wafts/sqft x 3.41 BtuhlWaft = o
Infiltration: 1.00 x 4 840 x 1 326 x 10.25 x 0.50 60] 0.00433 = 2 373
--- chedule Air Latent Area Ceilinc Height ACH Dyy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,699
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 45 of 46
RESIDENTIAL ROOM COOLING LOAD SUMMARY
The Palley Residence' 6/8/2005
Project Title Date
Room Name Kitchen/Dining/Family
o
Design Indoor Dry Bulb Temperature; 78oF
Design Outdoor Dry Bulb Temperature: 115 F
Design Temperature Difference: 370F
Conduction Area U -Value DETD 1 Btu/hr
X
X = '
X =
X —
X =
X =
X =
X =
X =
1. Design Equivalent Temperature Difference (DETD) Page Total
01
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded ' Unshaded
Solar Gain Orientation Area SGF Area SGF Sc Btu/hr
FxdGISWdw (1 (West) ( 0.0 x 1 + 18.6 x 73)X 0.423 = 574
F-cdGls,W-dw_(tl (West) ( 0.0 x 1 + 40.0 x 73 ) x 0.423 = 1,235
FxdGlsWdw U _ est ( 0.0 x 1 + 18.6 x 73)X 0.423 574
ti. ( -x + x )x =
( x + x )x =
( x + x )x =
( x + x )x =
( x + x )x =
( x + x )X
Sched. i Page Total 2.3154
Internal Gain Frac. Area' r Heat Gain Btu/hr
Lights 1.00 X 1,326 X 0.500 Watts/sqft x .3.41 Btuh/Watt — 2,263
Occupants ' 1.00 X 1,326 X' 250 Btuh/occ. / 200 sqft/occ. = 1,658'
Receptacle 1.00 x 1,326 X 1.500 Watts/sqft x 3.413 Btuh/Vllatt = 6,788
Process 1.00 x 1,326 x X0.000 Watts/sqft x 3.413 Btuh/Watt = o
Infiltration: oo x I 1 891 x 326 x Q 2 J x 60] A4529
Schedule Air Sensible Area Ceiling Height, ACH LST
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 37,8691
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 1326 x 200 Btuh/occ. / 200 sgft/occ. = 1 326
Receptacle 1.00 x 1 326 x ` 0.000 Watts/sqft x 3.41 BtuhlWatt = 0
Process r 1.00 x 1 326 x 0.000 Watts/sqft x 3.41 BtuhlWatt = o
Infiltration: I 1.00 x 4840 x 1 32 x 10.25 x 0.50 / 60] 1 0.00433 = 2 373
chedule Air Latent Area Ceiling Height ACH ZSW
Fraction
TOTAL HOURLY LATENT HEAT'GAIN FOR ROOM 3,699
EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:46 of 46
h