Loading...
05-1472 (SFD)4 P.O. BOX 1504 VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 6/20/05 Application Number: 105'-0-0001'4-72 Owner: - •Property Address: 80255 VIA MIRASOL BOB & LYNN'-LUNN APN: 772-430-006- - 4682 VISTOSA A Application.description: DWELLING'- SINGLE FAMILY DETACHED SANTA BARBARA CA Property Zoning: LOW DENSITY RESIDENTIAL SANTA BARBARA, CA "93110 Application valuation: 524959 Contractor. Applicant: D Archi r Engineer: JOHNSTON CONSTR INC., D.W. ' JUIN! ���� 1445 N.: SUNRISE WAY, #203 PALM SPRINGS, CA 92262 WCC: STATE FUND r/ l CITY OF L�►QUIP�I$lQC . ,No .: OOR SQUARE. FOOT Lic . No . c B ; V' FINANCE DEP4 � ,--------------------------------------------------------------------------------------------------- LICENSED -------------- ------ LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION - I hereby affirm under.penalty of perjury at 1 am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: - - - _ .�. Section 7000) of Division 3 of the.Busin ss and Professionals Code, and my License is in full force and effect. • _ I have and will. maintain a certificate of consent to self-insure for workers' compensation, as provided License CI s: License No.:. B „ y.- for by Section 3700 of the Labor Code, for the performance of the work for which this permit is ' r 1 • l - _ - issued. - f « Dat _t_e_ VJ Contractor` r: �+" �w ��i�l - , - _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor • - " Code, for the performance of the work for which. this permit is issued. My workers' compensation OWNER-BUILDER DECLARATION - • - insurance carrier and policy number area •' ` - - I hereby affirm under penalty o perjury hat I am exempt from the Contractor's State License Law for the Carrier 1640856-2005 01/01/06olicy Number 699640. following reason (Sec. 7031 .5, ' ss and Professions Code: Any city or county that requires a permit to 1 • _ I certify that; in the pe mance of the work for which this permit is issued; I- shall-not,employ any ��.. construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the 'person in any manner as to become subject to the workers' compensation lawsJof California, " permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State - and agree that, if I shou become subject to the workers' compensation provisions of Section - l` License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the Labor Code I shall forthwit omply with tho rovisions. tr; that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 -by 11 any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ' a Applican�i - I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or off ered.for sale (Sec. 7044, Business and Professions Code:. The WARNING: FAILURE TO SEC EW KERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL r Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER 70 AL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION,. DAMAGES AS PROVIDED FOR IN • improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION_ 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner-builder will have the burden of proving that he or she did not build or - - improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT - 1 _ 11, as owner of the,property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. - property who builds or improves thereon, and who contracts for,the projects with a contractor(s) licensed 1 . Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any. permit issued as a result of this application, (_) lam exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City _ of La Quinta, its officers, agents and employees for any act or omission related to the work being " performed under or following issuance of this permit. Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of, such permit, or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit to cancellation. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that th above information is correct. I agree to comply with all ' work for which this permit is issued (Sec. 3097, Civ. C.). city and county ordinances and state laws relating to build g construction, and hereby authorize representatives _ of this c unty o enter upon the above-mentioned propertyor inspection purposes. Lender's Name: Dat Signature(Applicant-or-Agentl:y- Lender's Address: LQPERAIIT: ' Application Number 05-00001472 - Permit . . BUILDING PERMIT Additional-desc Permit Fee 2114.50 Plan Check Fee 1374.43 Issue Date . . . Valuation .. . . . 524959 Expiration Date 12/17/05 Qty Unit, Charge Per Extension BASE FEE 2039:50 25.00 3.0000 THOU BLDG 500,001-1,000,000- 75.00 " T/2 Permit . . . . . ELEC-NEW RESIDENTIAL Additional,-desc •. Permit Fee . . . 264.89.-. Plan Check Fee 66.22 Issue Date" . . . Valuation 0 ExpirationDate 12/17/05J: , Qty Unit' Charge, Per Extension BASE . FEE 1.5.00 6,13,8.00 .0350 ELEC NEW RES'- 1 OR 2 FAMILY 214:83 ' 1003.00 '0200 ELEC GARAGE OR NON-RESIDENTIAL 20.06 1.0:0 .15.0000 EA ELEC TEMPORARY.POWER'POLE > Permit . . . . : . GRADING PERMIT Additional desc Pormit Fee 15.00 Plan Check Fee.. .0.0. Issue Date -: 'ValuaL`iun n. Expiration Date 12/17/_05. Qty Unit Charge Per Extension df BASE FEE 15.00 �3 Permit MECHANICAL " Additional desc .. Permit Fee 162.00 Plan Check Fee 40.50 _. Issue Date Valuation 0 Expiration Date 12/17/05 Qty Unit Charge Per Extension BASE FEE 15.00 6.00 9.0000 EA MECH FURNACE <=100K 54.00 6.00 9.0000 EA MECH B/C <=3HP/10QK BTU. 54.00. 5.00 6.5000 EA MECH VENT FAN 32.50 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 LQPERAUT - Application Number . . . . 05-00001472 - Permit PLUMBING " Additional desc - Permit Fee 257.25 Plan Check Fee 64.31_ Issue Date- .. Valuation.. _ 0 " Expiration Date 12/17/05` ; Qty Unit Charge Per ` Extension BASE FEE 15.00 - 27..00',, 6.0000 EA - PLB"FIXTURE 162.00 - 1.00 15.0000 EA PLB-BUILDING SEWER 15.00 2.00 6.0000 EA PLB ROOF DRAIN` -12.00 V.2'. 00 7.5000 EA PLB WATER HEATER/VENT 15.00 ,.Y 1.00 3.0000 EA PLB WATER•INST/ALT/REP - 3.00 41 - 1.00 9.0000 EA PLB LAWN SPRINKLER .SYSTEM + 9 . 00 , L 15.00 .7500 EA PLB GAS PIPE >=5 11.25 1 1.00 15.0000 EA PLB GAS METER r 15. 00, - ------- -'-- ti --='Special -------- -, F. } Notes and Comments- --- fi-----+-- f 6138 SQ. • FT.. `'SFD . .THIS PERMIT. DOES; NOT... INCLUDE POOL & SPA BLOCK WALLS OR yDRIVEWAY,APPROACH.June 14,2005 4:23:42,_ PM JJohnson - }•� - .--.-=------ - - -- -- -- - -- - -- ---,-- :---------- - - - - =- - - Other Fees ART IN PUBLIC PLACES -RES', - - - ------ -- a 812.. 39 �r DIF COMMUNITY CENTERS -RES 97.00 DIF,CIVIC CENTER - RES "366.00 ENERGY REVIEW FEE - 137.44 DIF FIRE PROTECTION. -RES' w w 97.60" GRADING PLAN CHECK FEE 00 DIF LIBRARIES - RES 225:00" - DIF PARK MAINT FAC - 'RES. - 5:00. " .: DIF' PARKS/REC -' RES'k R 50200, � '' .i STRONG MOTION (SMI)' - RES °" 52.49,_ _ t ,., DIF STREET MAINT FAC'=RES 15:00 ' -DIF TRANSPORTATION_- RES 1098.00 ' Fee summary Charged "' Paid _ Credited-. Due , ----------------------- - --- ----- 7-7------------ ---------- Permit Fee Total 2813.64 00 2813.64 _00 Plan Check•Total 1545:46 i -500.00 .00 1045.46 Other Fee Total '' 340,7.32• .00 00 3407.32 Grand Total 7766.42 500.00 ,.00 _ 7266.42- �: LQPEILMIT - . 1504 Building V o^ a5� I,A MrRAWL 78-4951CALOLE TAMPICO Address Lei Mi IN MA . C,A . LA QUINTF., CALIFORNIA 92253 Address 1.G8a N4ISTQCrA I Address 5 M. SAWSE WA`{ SUIS 403 City%M SMING S Zip Tel. I=A. I 1144 = teen/4'1G-- ti44- State Lic. Pc.# ity & Classif*g6Gq Arch., Enigr Designer +iL+W i"OA �ddr�sc . Tel. -TGO , CityPALM f Zip State C 9:;1aLic. # aciaI LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Sectio.. 7000) of Division 3 of the Business and Professions Code, and my license is in full force a OWNER -BUILDER DECLARATION I reby affirm that I am exempt from the Contractor's License Law for the Ilowing reason: ec. 7031.5, Business and Professions Code: Any city or county which quires a permit to nstruct, alter, improve, demolish, or repair any structure, prior to its is ance alsP requires the plicant for such permit to file a signed statement that he is license pursuant to the provision l the Contractor's License Law, Chapter 9 (commencing with Se tion 7000) c` Division 3 0l Ih usiness and Professions Code, or that he is exempt therelro and the bast for the alleged a ption. Any violation of Section 7031.5 by any applicant for permit subject:: the applicant to a 'vil penalty of not more than live hundred dollars ($500). ❑ I, as owner of the operty, or my employees with wages as their sole c pensation, will de the work, and the stru ure is not intended or offered for sale. (Sec. 7044, usiness and Proles sions Code: The Cont for's License Law does not apply to an owner property who build= or improves thereon and ho does such work himself or through his o employees, provide) that such improvements a not intended or o/%red for sale. If, ho ver, the building or irrc provement is sold within o year o/ completion, the owner -build will have the burden c' proving that he did not build improve /or the purpose o! sale). O 1, as owner of the property, a exclusively contracting with tic sed contractors to construe the project. (Sec. 7044, Busine and Professions Code: The ontractor's License Law doe= not apply to an owner o/ property ho builds or improves they on, and who contracts for suca projects with a contractor(s) licen d pursuant to the Conte for's License Law) O 1 am exempt under Sec. B. & P.C. for this ason Date Owner WORKER'S COMP SATI DECLARATION hereby affirm that I have a certificate of on nt to self -insure, or a certificate of Worker': Compensation Insurance, or a certified copy t of. (Sec. 3800, Labor Code.) Policy No. Company O Copy is filed with the city. ❑ Certifie co is hereby furnished. CERTIFICAT F EXEM TION FROM WORKERS' C PENSATIO INSURANCE (This section need not be completed 'the permit is Io ne hundred dollars ($100) valuation or less). I certify that in the performan of the work for whi this permit is issued, I shall not employ any person in any manner o as to become subject Workers' Compensation Laws ct California. Date Owner NOTICE TO APPLICANT., If, iter making this Certificate of Ex ption you should become. subject to the Workers' mpensation Provisions o! the Labo Code, you must lorthwitr comply with such provisi s or this permit shall be deemed revok . CONSTRUCTION LENDING AGENCY I hereby affir that there is a construction lending agency for the pe rmance Of the wort: for which this p mit is issued. (Sec. 3097, Civil Code.) /Lender's'NaA ress ' a building permit when properly filled out, signed and validated, a is subject tv if work thereunder is suspended for 180 days. ity that I have read this application and state that the above informatio is correct. o comply with all city and county ordinances and state laws relating building tion, and hereby authorize representatives of this city to enter the above- entioned for inspection purposes. of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT os -ILI7z APPLICATION ONLY BUILDING: TYPE CONST. OCC. GRP. A.P. Number _; Legal Description) 0#ANNk(,LA ►QUIRTA-I CA ' Project Description SI!t-� t ALWATIO WAI NG AREA : Ian4l S.F. Sq. Ft. -7C4_3 Size ?�:3 S. Stories New fid Add ❑ Alter ❑ t/ Estimated Valuation PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL C/) REMARKS I4'7 S.F. No. Dw. ' Units Repair ❑ Demolition ❑ AMOUNT ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE C_ t . Coachella Valley Unified School District ' f This Box For Distriet Use Only 83-733 Avenue 55, Thermal, CA '92274 DEVELOPER FEES PAID (760) 398-5909 — Fax (760) 398-1224 AREA: - AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE* - ' RRCRIP.T. - CHF.CK 01 INITIAIA- ' CERTIFICATE OF COMPLIANCE - (California Education Code 17620) Project Name: Residencelsat'tle Hideaway Date: June 24, 2005 Owner's Name: Bob Lynn Lunn Phone No.- Project o.Project Address: 80-255 Via Mirasol La Quinta, CA Project Description: - 1 SFD APN: 772-430-006 Tract #: Lot #'s: . Type of Development: Residential -XX Commercial Industrial . Total Square Feet of Building'Are'a:' " 6,138 sq. ft.• Certification of Applicant/Owners: The person signing rtifies that the above information is correct and makes this statement under • penalty of perjury and further represents that he/she is aut�io ed to sign on behalf of the owner/developer. Dated: June 24, 2005 Signature: IAZ��r,. SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code ' Gov. Code Project E Agreement Existing Not Subject to Fee 17620 65995., Approval Prior to 1/1/87 Requirement Note: Number of Sq.Ft. 6,138 Amount per Sq.Ft. $ 2.88 Amount Collected $ 17,677.44 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt.," Business Services ' Certificate issued by: Elvira Mattson, Office Technician Signature: ' NOTICE OF 90 DAY PERIOD FOR PROTEST OYFEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081,.effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the,90-day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliances valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) ych extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. �lV:c!???ydocshlevlces?certificate orcomhliwicc ti>rm Gibles'.M USf:>.doc , 1/16/03 T r , FIDELITY NATIONALTTTLIv COA 'A1VY ®®C. a 2004-0,72S40S SUBDIVISIONDEPARTMENTe9i 1 4i2eea es : eaA Fee : 2s . ee r, Page 1 of 7 Doc T Tax Paid y, Recorded in Official Records, WHEN RECORDED MAIL TO: 1 e x''. County of Riverside Gary L. Or -so Assessor, County Clerk 8 Recorder Mr, and Mrs. Robert Lunn 24601 SE 9th Street Sammamish , WA 9.8074 * ' ; , I I��II) IlIIII III�I IIIII III�II III�I IMI III illll ILII I91I MAIL TAX STATEMENT TO K SAME AS -ABOVE DOCUMENT TRA M S U -.-PAGE' !' SIZE OA PC. OR NOCOR SMF I ML.C. A R .i COPY �ONC I REFUND NCNG ( EXAM NSFER TAX $ 825 00 XX Computed on "the consideration or value of prop erty.conveyed; OR W Computed on the consideration or value less'liens or encumbrances remaining at the time of,sale.. Signature of Declarant.or Agent determining tax - Firm Name GRANT DEE. FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company ("Grantor"), hereby GRANT(S)to ROBERT C. LUPIN and LYNN'A. LUNN, husband and wife as joint tenants ("Grantee"), the real property, located in the City of La Quinta County, of Riverside, State of California, described as: See'Legal Description attached hereto. and incorporated herein'as Exhibit "A". SUBJECT TO all matters of:record including', without limitation, the covenants and agreements described in Exhibit."A" attached hereto. Dated: �.-!� _ ND LA QUINTA PARTNERS; LLC, a Delaware limited liability_ company By: Nationwide Realty Investors, Ltd. an Ohio limited liability company -its managing member T Joseph . Arenson Authorized Representative EXHIBIT "A" s Legal Description, Parcel No. 1 Lot 6 (the "Lot") of Amendment No. 2 Tract No. 29894-2, in the City of La Quinta, as shown by Map on file in Book 359, Pages 68 to 82, inclusive, of Maps, in the Office of the County Recorder of Riverside County, California. EXCEPTING AND RESERVING THEREFROM TO GRANTOR, and its successors, assigns, invitees, licensees and employees, together with the.right to grant and transfer all or a portion of the same, all easements and rights for access, ingress, egress, encroachment, maintenance, drainage, support, and for other purposes over the Association Maintenance _Areas and other portion of the Lot, reserved to Grantor in the following insiruinents: 1. The Amended and Restated Declaration of Covenants. Conditions and Restrictions and Reservation of Easements for The Hideaway Owners Association (as w.nended or supplemented, the "Declaration"), recorded on December 13,.2002, as Instrument No. 2002- 74598, of Official Records of Riverside County, California (the "Official Records"); 2 The Supplementary Declaration of Annexation of Property, recorded on August 19, 2004,..as Instrument No: 2004-0656071, of Official Records of Riverside Country, California. FURTHER RESERVING THEREFROM, the right to enter the Lot for a term of twely (12) months following the recordation of this Grant Deed, to complete and repair any { imprOvements or landscaping located thereon as determined necessary by Grantor, in its sole discr,:tion, in order to comply with requirements for the recordation of the Final Tract Map, the grading of said Tract and/or in"compliance with the requirements of applicable governmental agencies. Such entry by Grantor shall be preceded by reasonable notice to Grantee before such entry. If this reservation of right of entry is not complied. with. by Grantee, Grantor may enforce this right of entry in a court of law. Grantee shall be responsible for all damages arising out of said breach including attorneys' fees and court costs. This reservation of right of entry shall automatically expire twelve (12) months from the recordation of this Grant Deed. Parcel l Jo. 2: x - Nonexclusive easements for access, ingress, egress, drainage, maintenance, repairs and for otlier purposes, all as described in the Declaration. 4 SUBJI: CT TO: l . Non. delinquent general, special and supplemental real property taxes and asse:.si lents,. - ( F i 2. All other covenants, conditions, restrictions, reservations, easements, rights and 'rights-of-way of record including, without imitation, the Declaration and the Map for Amendment No..2 _Tract No. 29894-2. ' Grantee, by acceptance and recordation of this Grant Deed, hereby (a) accepts and approves all of the foregoing in this Grant Deed, (b) grants to Grantor and The Hideaway Owners Association such powers and rights as are set forth in the Declaration, and (c) accepts, covenants and agrees to be bound by and assume performance of all of the applicable provisions and requirements set forth in the Declaration, including Section 13.15 establishing the procedure for resolving disputes with Grantor, and the notice, which provisions and requirements are acknowledged to be reasonable and incorporated herein by this reference thereto. This grant is conditioned upon the performance of such provisions and requirements as are to be performed by . Grantee under the Declaration. The restrictions on use and occupancy of the Lot are set forth in the Declaratio:i to which this Grant Deed is specifically and expressly made subject, GRANTEE HEREBY" ACCEPTS AND APPROVES. -THE FOREGOING, granting unto ; Grantor and ':l•'he Iiideaway Owners Association such powers and'rights which are set forth in the Declaration dofined above, on 2004. Robert Chav;les Lunn n Anderson Lunn i Pas Lit STATE 0. id/C_Sh;17 F _ COUNTY Oa.+ 41174— } ss• � } On _ _ X _ 2004, before me, the undersigned, a notary public in anc for said State, personally appeared Robert.Charles Lunn and Lynn Anderson Lunn, perso; pally known to me or proved to me on the basis of satisfactory evidence) to be the persons whose names are subscribed to the within instrument and acknowledged to me that they executed the same in their authorized capacities, and that. by their signature on the instrument the perl.ons, or the entity upon behalf of which the persons acted, executed the instrument. Wi TNESS N1 Y HAND AND OFFICIAL SEAL, A ares (SEL) ati °0000 0° • (.. YL'oo� ' �?°. _ , ��_ r Bin # City of La Quinta Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # r,r�7'1 Project Address: Owner's Name: vv�J (�g1.►r.1 Lv� 4 A. P. Number: Address: Legal Description: City, ST, Zip: Contractor: W 0 Telephone: pS• J'a �, (o �((� N Address: (ttg—S— S'vNyLISL Project Description: G) rA-Lr�j Y44V(4 f4, City, ST, Zip: Telephone: Lit(. (t.� ' t State Lic. # : Arch., Engr., Designer: &"Vtstnikd�t City Lic. #: tt S� Address: 41460 v, City, ST, Zip: Telephone: ,.((o�a, State Lic. #:C,,.457tW r t Name of Contact Person: �q�— O, ve Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING. PERMIT FEES Plan Sets Plan Check submitted (t Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cates. Called Contact Person Plan Check Balance Energy Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading. plan' 2"d Review, ready for correct i s/issue `ItS Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue 7 School Fees Total Permit Fees L— B-0 GO V - V .Job • :60978-Q .. Plan : CUSTOM. consulting group,inc. Client : Holden & Johnson' { Engineer. JIM Beam Id: Stringer r Date :02/21/2005(Ver7.25) Loads (Downward +) CBC 2001(ZONE 4) Beam Weight 30.0 PLF FRCM 0.0' to 16.0- -Sec. Floor/Deck 353 PLF= 5.0' x (41+100)/2 from 0.00' to 16.00' " •.r 16.00' i f i Down (DL+LL/Max.) 3060/3060 3060/3060 + UP (DL+LL/Max.) 0/0 0/0 *** USE Parallam 5 1/4,x 14 (Fb=2800 Fv=285) DROP BM/HDR Gitical Shear 2566 • LB @ 1.29' 1.5 x Shear/(Fv x,)=0.184 (Fv=285 A --*73.50) 1 Critical Moment = 12240 LB x FT @ 8.00' Ratio=0.31 I (Fb= 2752 S= 171.50) ' Critical Deflection -0.154 - INCH @ 8.00' Based on (U 480) = 0.400 r r r. A f ' • ' Diagrams Of The Controlling Load Combination, Reflecting The Critical Values Respectively. c Shear Diagram ' DL + FL_L :. 12240' Moment Diagram DL + FL_L ' Deflection Diagram 1 `^+. /Q 8c SqF Q`il, i Co l4® �oFpT' ?ac 0 17 -0.154 e • .. ., 4 4 i r t ♦ yGO IS © t I B O V - Job :60978-Q ` ,.r • ti Plan CUSTOM consulting group Mc. Client' : Holden & Johnson + - Engineer. JIM : Beam Id: 59 Stringer - Date 02/21 /2005 ,�'L� �• f (Ver7.25) • CBC 2001(ZONE 4) F - Loads (Downward +) • Beam Weight 30.0 PLF FRCM 0.0' to .16.0' Sec. Floor/Deck 353 PLF= 5.0',x (41 +100)/2 from 0.00' to 16.00'-' ' - 16.00' Down (DL+LL/Max.)' 3060/3060 to 3 ' ^` f • r . ' " 3060/3060 V Up (DL+LL/Max.) 0/0 < r •'� ? 0/0 y . *** USE DFL NO 6 x 1.4 (Fb=1350 Fv= 85) DROP BM/HDR *** y Critical Shear = 2582 LB @ 1.25' 1.5 x Shear/(Fv x A)=0.614 (Fr— 85 A,— 74.25) • a Critical Moment = 12240 LB x FT @ 8.00' Ratio -0.663 •(Fb=r 1327 S= Critical Deflection = -0.204 INCH @ 8.00` Based on (U 480) = 0.400 ~i.•� •it - a .. -3 ,• -' +,. '- r•` '� rr' .•'. •t.-' a -" '+. . R4 sO tL •;,* Diagrams Of The Controlling Load Combination, Reflecting The Critical Values Respectively. 2582 Shear Diagram }} DL + FL_L 12240 - R, Moment Diagram 4.1 eve Tye _ Deflection Diagram y • �' F� �� (g S�F Qv��� LC -0.104 \lV � 71�'� B-0 G O V- I c V811110861`1110 • Job : 60978-Q tI Plan :'CUSTOM consulting group,mc. Client : Holden}& Johnson A Engineer. JIM Beam Idi 60 BM SUPPORT STRINGER` ° . Date :02/21/2005(Ver7.25) Loads (Downward +) t CBC 2001(ZONE 4), Beam Weight 20.0 PLF FRCM 0.0' to 6.0' Point From(P I) @1.50'(R. of BM 59) Y ' Point From(P2) @6.00'(8. of BM 59) • , k, Primary Floor 138 PLF= 5.0' x (15+40)/2 from 0.00' to .6.00' = ? - ♦ :Point Load Location ' PI ' 5.00'' r . - 6.00' ,. ji Y 1.50' - Down (DL+LUMax.) 2318/2318 • 5157/5157 Up (DL+LUMax.) 0/0 00.. , • *** USE DFL NOH' b+z 12 (Fb=1350 Fv=µ85) DROP BM/HDR *** W/ 'right2,2x6 trimmer/stud Critical Shear = 2147. LB @ 1.08'-`1.5 x Shear/(Fv x,,4)=0.599 (Fv:; 85,4-: 63.25) Critical Moment = 3300 LB x FT @ 1.50' Ratio=0.242 (Fb= 1350 S= 121.23) • r `. Critical Deflection = -0.007 INCH @ 6.00' ' Diagrams Of The Controlling Load Combination, Reflecting The Critical Values Respectively. { 2147 .� _ c Shear Diagram t DL + FL_L , .3300 Moment Diagram r i DL + FL_L R - * F. Deflection Diagram ` t DL + LL a -0.007 Ce'rtiftcate ®f Occupancy G� OF T�wBuilding & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance,. this structure was in compliance with .the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. RI IIL..DING ADDRESS: 80255 VIA MIRASOL Use classification: SFD Building Permit No.: 05-1472 Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL Owner of Building: M/M BOB LUNN Address: 4682 VISTOSA City, ST, ZIP: SANTA BARBARA By. G HARTMAN Date: 6-23-06 Building Official POST IN A CONSPICUOUS PLACE TITLE 24 REPORT' ' 'Title 24 Report for dJ►NTA i The' Lunn Resident' CITY OF LA Q Lot #6F @ The Hidea, aPUILDING &SAFETY DEPT. F .. La Quinta , CA 9225 APPR®� T►® FOR CONSTR to bA - Project Designer: R Holden & Johnson / Architects 44-267- Monterey Ave:, Suite A Palm Desert, CA 92260 b (760)..340-719811. -Report Prepared 13 CJ McFadden` BREEZE AIR CONDITIONING 75-145 ST CHARLES PLACE PALM DESERT,, CA 9221.1 '(760) 346-0855 h Job- Number.,,,... et Date: 5/9/2005 The Ener mputer program has been used to perform the calculations summarized inthiscompliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and -Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number. 3665 0 Cover Page Table of Contents ,' 2 Form CF-1 R Certificate of Compliance ',`. 3 Form MF-1 R Mandatory Measures Checklist8 Form C-2R Computer Method Summary'-,-.,10 Form ENV-3 Proposed Construction Assembly. 19 HVAC System Heating and Cooling Loads Summary 20 Room Load Summary 4 ' 25 Room Heating Peak Loads 30 Room Cooling Peak Loads _ 35 EnergyPro 3.1 By EnergySoft Job Number. ' r. User Number: 3665 ' Certificate of Compliance: Residential (Part 1 of 2) CF -1 R A The Lunn Residence 5/9/2005 Project Title Date Lot #6F C) The Hideaway La Quinta Project Address Building Permit # BREEZE AIR CONDITIONING 1760) 346-0855 Plan Check/ Date Documentation Author . Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 6,138 ft2 Average Ceiling Height: 11.0 ft Total Conditioned Slab Area: 5,602 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (North) 0 deg Number of Dwelling Units: 1.00 Number of Stories: 2 Floor Construction Type: ® Slab Floor Raised Floor FENESTRATION Shadina Devices Type Orientation Const. . Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) R-38 Roof (R.38.2x14.16) Wood 0.025 Exterior Roof R-21 Wall (W.21.2x6.16) Wood 0.057 Exterior Wall Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Solid Wood Door Wood 0.387 Exterior Door Raised Floor Wood 0.028 Exterior Floor / Over Open Space x❑ Rear (South) 281.5 0.40 0.35 FENESTRATION Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Left (East) 64.6 0.40 0.35 Bug Screen ❑ 0 ❑ X❑ Left (East) 54.0 0.80 0.59 Bug Screen ❑ X❑ ❑ x❑ Rear (South) 281.5 0.40 0.35 Bug Screen ❑ 0 ❑ x❑ Right (West) 66.0 0.55 0.29 Bug Screen ❑ -1 ❑ x❑ Right (West) 204.8 0.40 0.35 Bug Screen ❑ X❑ ❑ x❑ _ . Front (North) 173.4 0.80 0.59 Bug Screen ❑ X❑ ❑ X❑ Front (North) 33.0 0.55 0.29 Bug Screen ❑ X❑ ❑ X❑ Left (East) 63.3 0.55 0.29 Bug Screen ❑ x❑ ❑x❑ Front (North) 140.6 0.40 0.35 Bug Screen ❑ X❑ ❑ x❑ Left (Southeast) 27.0 0.80 0.59 Bug Screen ❑ X❑ ❑ X❑ Rear (South) 97.0 0.40 0.35 Bug Screen a ❑ ❑ a Rear (South) 108.0 0.50 0.36 Bug ScreenX❑ ❑ ❑ R] Run Initiation Time: 05109/05 4:07:56 Run Code: 1115672876 Ener Pro 3.1 By Ener Soft User Number: 3665 Job Number: Pa e:3 of 41 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R The Lunn Residence Fenestration 5/9/2005 Project Title Date Lot #6F e- The Hideaway 'La Quinta SHGC Project Address Yes / No Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Check/Date Documentation Author Telephone 0.59 Computer Performance 15 Field Check I Date Compliance Method (Package or Computer) Climate Zone _ Enforcement Agency Use Only GENERAL INFORMATION 54.0 0.80 Total Conditioned Floor Area: 6,138f? Average Ceiling Height: 11.0 ft Total Conditioned Slab Area: 5,602 ft2 Building Type: (check one or more) ❑❑ Single Family Detached ❑ Addition - ❑ Single Family Attached . ❑ Existing Building ❑ Multi -Family ;, . ❑ Existing Plus Addition Front Orientation: (North) 0 deg Floor Construction Type: ® Slab Floor' Number of Dwelling Units: 1.00 .. -. Number of Stories: -2 Raised Floor Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) FENESTRATION Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Rear (Southwest) 27.0 0.80 0.59 Bug Screen ❑ ® ❑ x❑ Rear (South) 54.0 0.80 0.59 Bug Screen ❑ X❑ ❑X❑ ❑❑ El F1 .. -. ❑ ❑ ❑• ❑ .. .. ..: ❑ ❑ ❑ ❑ - ❑ ❑ ❑ ❑ -_ ❑❑ El El El El El - 11 El 0, 1:1 1:1 ❑❑ Run Initiation Time: 05/09/05 14:07:56 Run Code: 111567 876 Ener Pro 3.1 By Ener Soft User Number: 3665 Job Number: Pa e:4 of 41 4 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R The Lunn Residence 5/9/2005 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency, Location Piping ' Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC #1 Central Furnace 80% AFUE Ducts in Attic - 42 Central Furnace 80% AFUE Ducts in Attic 4.2- Setback HVAC #2 Setback ' HVAC #3 Central Furnace 80% AFUE Ducts in Attic 4.2- Setback HVAC #4 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC #5 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct .: ' Thermostat Location'/ heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 42 Setback HVAC 91 Split Air Conditioner 14-0 SEER Ducts in Attic 4-2 Split Air Conditioner 14.0 SEER Ducts in'Attic 4.2' Setback HVAC #2 Setback HVAC #3 Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC #4 +•` Setback HVAC #5 WATER HEATING SYSTEMS Rated 1 • Tank Energy Facts 1 External Water Heater Water Heater Distribution " #'in , input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A -0 -Smith FGR -75 Large Gas Recirc/Time+Temp 2— 76.000 - 75 0.72 0-0000 0.0 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. RGMADLeQ COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: CJ McFadden Title/Firm: Holden & Johnson /Architects Title/Firm BREEZE AIR CONDITIONING Address: 44-267 Monterey Ave., Suite A Address: 75-145 ST. CHARLES PLACE Palm Desert, CA 92260 PALM DESERT, CA 92211 Telephone: (760) 340-1981 Telephone: (760) 346-0855 Lic: #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: D (signature) ( te) Certificate of Comaliance: Residential (Addendum) CF -1 R The Lunn Residence 5/9/2005 Project Title Date Special Features and Modeling Assumptions ' The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The HVAC System "HVAC #1 " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 106 sqft Tile in Mortar Interior Mass, 0.75' thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 106 sqft Exposed Slab Floor, 4.00" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 956 sqft Covered Slab Floor, 4.00" thick at Master Suite The HVAC System "HVAC #2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) -Verify Thermal Mass: 173 sqft Tile in Mortar Interior Mass, 0.75' thick at Bed #2 /Media/ Game R HIGH MASS Design(see C -2R) - Verify Thermal Mass: 173 sqft Exposed Slab Floor, 4.00" thick at Bed #2 / Media / Game Rm HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1300 sqft Covered Slab Floor, 4.00" thick at Bed #2 / Media / Game Rm The HVAC System "HVAC #3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2319 sqft Tile in Mortar Interior Mass, 0.75' thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2319 sqft Exposed Slab Floor, 4.00" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 334 sqft Covered Slab Floor, 4.00" thick at Living Area The HVAC System "HVAC #4" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. 'HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC #1 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow: The HVAC System "HVAC #2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #5 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. ' Run Initiation Time: 05/09/05 14:07:56 Run Code: 1115672876 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page:6 of 41 Certificate of Compliance: Residential Addendum CF -1 R The Lunn Residence 5/9/2005 ' Project Title Date Special Features and Modeling Assumptions ' The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted.'. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 41 sgft Tile in Mortar Interior Mass, 0.75" thick at Bedroom #3 ' HIGH MASS Design(see C -2R) - Verify Thermal Mass: 41 sqft Exposed Slab Floor, 4.00" thick at Bedroom #3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 373 sgft Covered Slab Floor, 4.00" thick at Bedroom #3 ' The HVAC System "HVAC #5 " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of aJCEC approved HERS' provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field Run Initiation Time: 05/09/05 14:07:56 Run Code: 1115672876 !nergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:7 of 41 ' Mandatory Measures Checklist:: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into ' the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. 1 DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures , ❑X '§ 150(a): Minimum R-19 ceiling insulation.. ` y: IT ❑ § 150(b): Loose fill insulation manufacturers labeled R -Value. Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does • §150(c): X ❑ not apply to exterior mass walls): " ❑ ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 pemdinch. { ❑X § 118: Insulation specified or installed meets insulation quality standards. ` Indicate type and form. §116-17: Fenestration Products, Exterior Doors and I nfiltration/Exfil tration Controls v 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage., 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. r 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. . ❑§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑§150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑X § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. Y` 1. Masonry and factory -built fireplaces have: Y a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating'and Plumbing System Measures a§ 110-13: HVAC equipment, water heaters, showarheads and faucets certified by the Commission. ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE; SMACNA orCCA. ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. X§1506): Pipe and Tank Insulation ' 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external - insulation or R-16 combined intemal/extemal insulation.., 4. All buried or exposed piping insulated in recirculating sections of hof water systems. f 5. Cooling system piping below 55 degrees F. insulated. • dr + 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 3665. -.,Job Number.- Page:8 of 41 IT ' Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowdse residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an ' asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. . DESCRIPTION Instructions: Check or Initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) X❑'§150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, . 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181S. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or Flexible duct shall not used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. - r; 5. Gravity ventilation systems serving conditioned space have eitherauiomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water'retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipments 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no.electric resistance heating, and no pilot. f 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future, solar heating.: b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. X❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no . r continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑§118 (f): Cool Roof material meet specified criteria Lighting Measures` „ RX §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. X❑ §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater, switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC.(insulation cover) approved., Computer Method Summary Xl 1X 1X ❑ ❑ ❑ (Part 1 of 3) C -2R es.ide.nce 1X �� EX 1X � _ 1 X_ X X E )-Q X X 01X [X 1X X ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1-1R- ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 5/9/9 0r, 'Zhe_Lunn- Project Title _Lot_#6.F_ a-Th.eJ:i.d.eaway La-Q.u.inta Som - R2LWalL(.W_ __2].2x616) Solid Wood Door Date Project Address R21_WaIL(W_ _21.2x6.16) R38_Roo.L(R_38_2x]4J6.) R2LW_ail-k 21.2x616) Building Permit # _Raised_Eloor. R38�tooQR38..2xL416.) _R2LWalL(W.21.2x616.) .R21_W-alL(W.2 -2x66-6) R-21 WaIL(W 21-2x616) (760) 346-0855 Plan Check/Date '_BREEZEAI.EZCQNUT_LO-N.LDLG Documentation Author � Telephone -o put 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone ' Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.79 3.93 -0.14 Cooling 33.64 34.58 -0.94 'Space Domestic Hot Water 4.64 3.39 1.25 Totals 42.07 41.90 0.17 Percent better than Standard: 0.4% ' BUILDING COMPLIES Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name .HVAC #1 .H_VAC #2 .H -VA _H_VA_ C #4 6,138 ft2 Single Fam Detached (North) 0 deg 1.00 2 OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Floor Area Volume 10 2 1.473 2,6.53. 414 Solar Gains Y/N -10,620 t4,.362 _33,].62 4,.55_4 Floor Construction Type: X❑ Raised Floor[g] Slab Floor Total Fenestration Area: 22.7% Total Conditioned Volume: 67,656 ft 3 Total Conditioned Slab Area: 5,602 ft 2 # of Thermostat Vent Units Zone Type Type Hgt. Area _0-17 Conditioned- -Setback- 8 -nla _0..2.4_ -Conditioned- -Setback- 8 _nla _0..43_ Conditioned_ Setback_ 8 _nLa Q_QZ_ Conditioned_ Setback- 8 --nLa Form 3 Reference .Roof l 062 0.025 34.5 0 Wall- 242 -0-057- 90. 9.0 Wall_ X88 -0-057- X8.0 90 Wall X00 ---0-057- -270 90 Xl 1X 1X ❑ ❑ ❑ R38BoQL(IZ38 2x14.16) R-2:1WaIL(W_ __21.2x6.16) R2.1_Wall_(W.2]_2x6 1 6.) R21_W L(W21.2x616) .Roof 0 47-3 --0-02.5- 34.5 Wall_ _20.3_ -0-05.7- 0. 90_ Wall- _2.69 0 057_ 90. 9Q Wall_ X11 -0-057- _270 90 Roof _2,6.53 -0_025_ _3_4.5 0_ Wall- 320 0-0.57 0 90 .D.o.or 24 3..387_ 0 90 Wood -Door --Wall_ _2.52 0057- 90 90 .Door 24 _038.7 90_ -90_ Wall- 81 0.057 ---135 9Q Wall- X52 -0_057- x_80 9Q Wall_ 8i 0_0.57 -225 90 Wall_ 211 --0-057- SZo_ 90 Roof 414_ --0-025- -345 0 Wall- 108 Q_057- 0 90 Wall- 324 0057- 90 90 Wall_ 66 --0-057- ---180 90 .Elo.or 5.0.0_ 0._028_ 0x.80_ Roof 5.3 5 .6_ _0_025 _3_4. 0 Wall_ 1.65. 0.0.5.7 0 _90 Wall_ _205_ -0.0.57_ 90 90 Wall- -22.0 0 057 t80. 90 Wall_ 17-4 -O-Q57- S.ZO 90 1X �� EX 1X � _ 1 X_ X X E )-Q X X 01X [X 1X X ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1-1R- ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ R_38-RooQR,38-2x]_4.1.6) R2_LWaIL(.W 21.2x6 IF; R21 IN_aIL(W21-24.16) R2L1N_aIL(W.Z 2x6 t6) R3.8_Roof_(R_38.2x]416.)- R2-1LWaIL(W 21.2x6J6.) Som - R2LWalL(.W_ __2].2x616) Solid Wood Door R21_WaIL(_W2] 2x6J6.) R2LWaIL(W 212x616.) Wall -(W 21.2x6J6.) R21_WaIL(W_ _21.2x6.16) R38_Roo.L(R_38_2x]4J6.) R2LW_ail-k 21.2x616) R--Z1-\A'aIL(W2L.2x616) R2LWaIL(W21.2x6J6) _Raised_Eloor. R38�tooQR38..2xL416.) _R2LWalL(W.21.2x616.) .R21_W-alL(W.2 -2x66-6) R-21 WaIL(W 21-2x616) R2_LWall_(W.2J_2x6.16) -Door 2Q 0..387 -27-0 90 L❑K� � Solid 1N_ood_Dom ZONE#1 ZONE12 20N ZONF #2 ZONE.#2 ZONE -0 ZONE -#'-3 ZONE -1 ZONE #3 .ZONE -3 ZONE -3 ZONE -0 .ZONE#4 ZONE�i4 .ZONE -#5 ZONEES ZO-N 20NE�kS 11 Location / Comments EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 10 of 41 1 Computer Method Summary (Part 1 of 3) C -2R _T_he-Lu.n.n_Resjde.nce 5/9I2QQ5 Project Title _Lot_#_6F_ a,The-B.d awa-y—La_Qu.i.nta bate Project Address Building Permit # BREEZE_AI-R-CORDMON.I.N_G (760) 346-0855 Documentation Author Telephone Plan Check/Date Compute.LPetfo— mance 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.79 3.93 -0.14 Space Cooling 33.64 34.58 -0.94 Domestic Hot Water 4.64 3.39 1.25 Totals 42.07 41.90 0.17 Percent better than Standard: 0.4% Total Conditioned Floor Area: 6,138 ft2 Building Type: Single Fam Detached Building Front Orientation: (North) 0 deg Number of Dwelling Units: 1.00 Number of Stories: 2 Floor Construction Type: 0 Raised Floor[X] Slab Floor Total. Fenestration Area: 22.7% Total Conditioned Volume: 67,656 ft 3 Total Conditioned Slab Area: 5,602 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area .HVAC -#.5 53.6 4.,9.58 —0_0.9_ Conditioned— —Setback_ Solar OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y / N Form 3 Reference ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ ❑❑ F-1 1-1 ❑❑ ❑❑ ❑❑ F-1 F-1 Location / Comments EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Paae:11 of 41 1 Computer Method Summary (Part 2 of 3) C -2R The Lunn Residence 5/9/2005 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Tvoe Area Factor SHGC Azm. Tilt Comments _L Window -Left (East)_ -27-0- 0.4D.0_ 0._3.5 9.0_ _90. Fleetwood_G.lazing ZONE #1 2 Window Left (East) 54.0 0.800 0.59 90 90 Fleetwood Glazing ZONE #1 3 Window Left East) 27.0 0.400 0.35 90 90 Fleetwood Glazing ZONE #1 4 Window Rear (South) 21.0 0.400 0.35 180 90 Fleetwood Glazing ZONE #1 5 Window Rear South 60.0 0.400 0.35 180 90 Fleetwood Glazing ZONE #1 6 Window Rear South 21.0 0.400 0.35 180 90 Fleetwood Glazing ZONE #1 7 Window Rigbt (West) 150 -L( .95Q 0.29 270 90 F11 etwood Glazing ZONE #1 8 Window Right (West) 33.0 0.400 0.35 270 90 Fleetwood Glazing ZONE #1 5 Wi!mlow igbL-- sit 0 0.400 0.35 _270 90 Fleetwood Glazing ZONE #1 J0 Window Front (North 40.0 0.800 0.59 0 90 Fleetwood Glazing ZONE #2 11 Window Front North 16.5 0.550 0.29 0 90 Fleetwood Glazing ZONE #2 12 Window Front North 40.0 0.800 0.59 0 90 Fleetwood Glazing ZONE #2 13 Window-F_r_ont_(North) X6.5 0-550 029 0_ -90 FleetwoocMiazing 2-QNE-#2 14 Window Left (East) 11.3 0.550 0.29 90 90 Fleetwood Glazing ZONE #2 15 Window Left (East) 14.0 0.550 0.29 90 90 Fleetwood Glazing ZONE #2 16 Window Left (East) 6.0 0.550 0.29 90 90 Fleetwood Glazing ZONE #2 17 Window Right (West) 30.0 0.400 0.35 270 90 Fleetwood Glazing ZONE #2 18 Window Right (West) 28.0 0.400 0.35 270 90 Fleetwood Glazinq ZONE #2 19 Window Right (West) 30.0 0.400_ 0.35 270 90 Fleetwood Glazing ZQNE #2 20 Window Right (West) 8.0 0.550 0.29 270 90 Fleetwood Glazing ZONE #2 21 Window Right (West) 15.0 0.550 0.29 270 90 Fleetwood Glazing ZONE #2 22 Window Front North 57.0 0.400 0.35 0 90 Fleetwood Glazing ZONE #3 23 Window Front (North) 60.0 0.800 0.59 0 90 Fleetwood Glazing ZONE #3 24 Window Front (North) 57.0 0.400 0.35 0 90 Fleetwood Glazing ZONE #3 25 Window Left (East) 24.0 0.550 0.29 90 90 Fleetwood Glazing ZONE #3 26 Window Left (Southeast) 27.0 0.800 0.59 135 90 Fleetwood Glazing ZONE #3 27 Window Rear (South) 82.2 0.400 0.35 180 90 Fleetwood Glazing ZONE #3 28 Window Rear (South) 47.0 0.400 0.35 180 90 Fleetwood Glazing ZONE #3 29 Window Rear (South) 48.5 0.400 0.35 180 90 Fleetwood Glazing ZONE #3 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt.. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 _ 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 -du6u Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Buy Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 7.8 6.2 10.0 2.0 10.0 10.0 Run Initiation Time: 05109105 14.07.56 Run Code: 1115672876 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Paae:12 of 41 Computer Method Summary (Part 2 of 3) C -2R . The Lunn Residence 5/9/2005 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC .Act. Azm. Glazing Type Tilt Location/ Comments _3.0. Window -Rear --(South) -48-5_ -0_4.0.0 0.35_ 1.8.0_ _90. Fleetwood -Glazing ZO.ME03 31 Window Rear (South) 108.0 0.500 0.36 180 90 Fleetwood Glazing ZONE #3 32 Window Rear (Southwest) 27.0 0.800 0.59 225 90 Fleetwood Glazing ZONE #3 33 Window Right West 14.0 0.550 0.29 270 90 Fleetwood Glazing ZONE #3 34 Window Right (West)_ 35.0 0.400 0.35 270 90 Fleetwood Glazing ZONE #3 35 Window Right (West) 14.0 0.550 0.29 270 90 Fleetwood Glazing ZONE #3 36 in ow Left (East) 8.0 0.550 0-.a 90 Fleetwood Glazing ZONE #4 37 Window Rear (South) 22.5 0.400 0.35 180 90 Fleetwood Glazing ZONE #4 38 Window Rear (South) 54.00.800 X53 189_ 9.0 Fleood Glazing ZONE #4 39 Win ow Rear (,South) 22.5 0.40Q 0.35 18Q 90 Fleetwood Glazin ZONE #4 49 Window Front (North) 13.3 0.400 0.35 0 90 Fleetwood Glazinq ZONE #5 41 Window Front North 33.4 0.800 0.59 0 90 Fleetwood Glazing ZONE #5 _4.2 Window_Eront (North) X3-3 -0-400- 0 35 0_ 90. FJeetwood_Glazing ZONEJU 43 Window Left (East) 5.3 0.400 0.35 90 90 Fleetwood Glazing ZONE #5 44 Window Left (East) 5.3 0.400 0.35 90 90 Fleetwood Glazing ZONE #5 45 Window Rear South 5.3 0.400 0.35 180 90 Fleetwood Glazinq ZONE #5 46 Window Right (West) 10.4 0.400 0.35 270 90 Fleetwood Glazing ZONE #5 47 Window Right West 25.0 0.400 0.35 270 90 Fleetwood Glazing ZONE #5 48 Wind9w Right (West) 10.4 X4_20_ 035 270 90 Fleetwood Glazing ZONE #5 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 7.8 6.2 10.0 2.0 10.0 10.0 31 Bug Screen 0.76 9.0 12.0 10.0 0.1 10.0 10.0 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 K9 Screen 0.76 EnergyPro 3.1 By EriergySoft User Number. 3665 Job Number: Parae:13 of 41 1 Computer Method Summary (Part 3 of 3) C -2R The Lunn Residence 5/9/2005 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference _ R -Val. Comments Tile i0 Aoltar �0& , 015 —2.4_ n1a 0 ZONE�#1LlnteriotMass Concrete. Heavyweight 106 _0..6.7 4_00 28 0_98 n/a 0 ZONE #1 / Slab on Grade Concrete amyweight 956 4.00 _2-8 0.98 n/a _2 ZONE #1 / Slab on Grade Tile in Mortar 173 0.75 , 24 0_67 n/a - 0 ZONE #2 / Interior Mass Concrete.-liea%W&ighf 173 4.00 Lja 0.98 n/a 0 ZONE #2 / Slab on Grade PERIMETER LOSSES ; F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 1 0.76 _00 9 ZONE #1 _S.labperameter 99 -0-7-6 —0-0. —0 ZQNE_#1 Slab Perimeter 17 -016 � 0 0 ZONE #2 Slab_eerimeter 905. -0-M 00 9 ZQN.E_#2 Slab-Eerimeter 150 0 M 0,0 9 ZONE#3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments C�Lt urnace 8Q% AFUE Ducts in Attic A2 Setback HVAC #1 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback • HVAC #2 Central Furnace 80% AFUE Ducts in Attic 4.2 - Setback HVAC #3 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC #4 Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct ` Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) ','R -Value Type Comments Sp1i At 9LQo_ndlitioner 140-SEEr i &tic 4,3_ wetback HVAQ #1 Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC #2 _Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC #3 Split Air Conditioner 14.0 SEER Ducts in Attic •' 4:2 Setback - HVAC #4 WATER HEATING SYSTEMS1 "Ratedl' Tank Energy Fact. 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. Btu/h0.__(gal) . Efficiency Loss (%) Ext. A.O.Smith FGR -75 Urge Gas Recirc/Time+Temp_ 2 76.900, 75 0.72 X0000 0.0 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. . For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. ZEMARKS Run Initiation Time: 05109/05 14:07:56 Run Code: 1115672876 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 14 of 41 Run Initiation Time: 05/09/05 14:07:56 Run Code: 1115672876 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 15 of 41 m '- Part' 3 of 3 Computer Method Summary ( ) C -2R The Lunn Residence 5/9/2005 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location ' Type (so (in.) Cap. Cond. Form 3 Reference R -Val Comments C9ncrete Heavyweight . ,0 -. _2& _0...9.8n/a 2. ZOIE#2LSIab��Gtade Tile in Mortar 2.319 0_75 24 0_67 n/a 0 ZONE #3 / Interior Mass Concrete Le eigbt 2 319 Q_ -0 5 n/a —0. ZONE #3 /Slab on Grade ' Concrete. Heavyweight 334 4_00 28 0_98 n/a 2 ZONE #3 / Slab on Grade Til.e_in_Motta.r. 4 0.75 24 0.0_7 n/a 0 ZONE #4 / Interior Mass PERIMETER LOSSES r - ' F2 Insulation Type Length Factor R -Val. Depth Location / Comments la Perimeter 17 0.76 _0.0 _Q ZONE #3 'Slab-Berimeter 0-Z6 _0_0 —Q ZIONE 4 S! b-Bre ii—nr .ater 5 0.7_6 Q.Q Q ZONE #4 ' HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct ,Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furna4e 80°F Q–u-cts in Attic -4.2 Setback MVAC #5 iHydronic Piping Pipe Pipe ylnsul.`. System Name Length Diameter - Thick. Cooling Equipment Minimum' Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments ' Slit Air Conditioner 14.0 SEER Ducts in Attic4.2 ..Setback HVAC #5 WATER HEATING SYSTEMS _ Rated/ Tank Energy Facts 1 Tank Insul. Heater Water Heater Distribution ' # in Input Cap. or Recovery Standby R -Value 'Water System Name Type . 'Type Syst. (Btu/hr) ' (gam Efficiency Loss (%) Ext. For small gas storage (rated input 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. ' For instantaneous gas water.heaters, oGn11A CVC list Rated Input, and Recovery Efficiency. . Run Initiation Time: 05/09/05 14:07:56 Run Code: 1115672876 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 15 of 41 m Run Initiation Time: 05/09/05 14:07:56 Run Code: 1115672876 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 16 of 41 a Computer Method Summary (Part 3 of 3) C 2R 'The Lunn Residence ' - 5/9/2005 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. HeatInside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete Heavyweight _4 _4_00 —28. _028. n/a 0. Z0NEJ9 LS1ab-onS.rade Concrete. Heavyweight 373 4_00 28 - . 0_98 n/a 2 ZONE #4 / Slab on Grade t PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments HVAC SYSTEMS Heating Equipment - Minimum Distribution Type; ' Type (furnace, heat Efficiency and Location Duct' Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Hydronic Piping Pipe Pipe'Insul. , w System Name Length Diameter' Thick. ' Cooling Equipment Minimum' Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, -etc,) R -Value ' Type Comments WATER HEATING SYSTEMS Rated/ : Tank Energy Facts Tank Insul. Water Heater Water Heater Distribution # 1n ..:.Input ' Cap. or Recovery Standby R -Value System Name Type Type Syst. -(Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery, Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. i ' T ' REMARKS Run Initiation Time: 05/09/05 14:07:56 Run Code: 1115672876 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 16 of 41 Computer Method Summary (Addendum) C -2R The Lunn Residence 5/9/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan Field The HVAC System "HVAC #1 " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 106 sqft Tile in Mortar Interior Mass, 0.75" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 106 sqft Exposed Slab Floor, 4.00" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 956 sqft Covered Slab Floor, 4.00" thick at Master Suite The HVAC System "HVAC #2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 173 sqft Tile in Mortar Interior Mass, 0.75" thick at Bed #2 / Media / Game R HIGH MASS Design(see C -2R) - Verify Thermal Mass: 173 sqft Exposed Slab Floor, 4.00" thick at Bed #2 / Media / Game Rm HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1300 sqft Covered Slab Floor, 4.00" thick at Bed #2 / Media / Game Rm The HVAC System "HVAC #3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -21R) - Verify Thermal Mass: 2319 sqft Tile in Mortar Interior Mass, 0.75' thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2319 sqft Exposed Slab Floor, 4.00" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 334 sqft Covered Slab Floor, 4.00" thick at Living Area The HVAC System "HVAC #4" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -61R. I Plan I Field The HVAC System "HVAC #1 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #4" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC #5 " includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:17 of 41 1 Computer Method Summary (Addendum) C -2R 'The Lunn Residence 5/9/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 41 sqft Tile in Mortar Interior Mass, 0.75" thick at Bedroom #3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 41 sqft Exposed Slab Floor, 4.00" thick'at Bedroom #3 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 373 sqft Covered Slab Floor, 4.00" thick at Bedroom #3 The HVAC System "HVAC #5 " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. 'Run Initiation Time: 05/09/05 14:07:56 Run Code: 1115672876 EnergyPro 3.1 By Energysoft User Number: 3665 Job Number: Page: 18 of 41 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 ,PROJECT NAME DATE The Lunn Residence 5/9/2005 COMPONENT DESCRIPTION DESCRIPTION AMING OUTSIDE SURFACE AIR FILM 1 stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 ASSEMBLY NAME R-21 Wall (W.21 .2x6.16) -0.31 7 0.37 8 2.60 ASSEMBLY Floor INSIDE SURFACE AIR FILM 0.680 23.11 TYPE (check one) X Wall W Ceiling / Roof aFRAMING MATERIAL Wood p Z FRAMING % 4 15 % Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) CONST SUBTOTA R -VALUE DESCRIPTION AMING OUTSIDE SURFACE AIR FILM 1 stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 -0.31 7 0.37 8 2.60 9 0.68 INSIDE SURFACE AIR FILM SUBTOTA R -VALUE THICK- NESS (in.) AMING El ❑ El © ❑ ❑ ❑ El, ❑ 0.170 0.875 0.010 0.375 5.500 0.625 - 21.000 5.445 0.5621- SUBTOTA R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.1751 0.175 0.060 0.060 0.465 0.465 21.000 5.445 0.5621- 0.562 -0.31 2.63 0.37 0.98 2.60 0.26 0.68 0.6801 0.680 23.11 7.56 Rc Rf. *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 0.0433 X 0.85 ] 8.46 0.20 1.69 0.061 0.35 0.02 1.06 0.29 -0.31 2.63 0.37 0.98 2.60 0.26 0.68 14.8 TOTAL HC 3 Weight and Specific Heat values for materials penetrated'by wood framing include the effects of the framing members. 0.0433 X 0.85 ] + [ 0.1323 T x 0.15 ] 1 / Rc 1 - (Fr-/. /100) 1 / Rf Fr% / 100 ASSEMBLY U -VA 3.1 By EnergySoft User Number: 3665 Job Number. 9of41 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1' HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Lunn Residence 5/9/2005 SYSTEM NAME FLOOR AREA HVAC #1 1,062 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 1,31 26,824 2,916 448 18,718 0 1,341 936 0 0 80 3,051 1,848 80 3,918 0 0 1,341 936 32,557 4,765 24 508 HS26-060/G40UH60C-110 (5) 46,657 4,988 89,400 Total Adjusted System Output 46,657 4,988 89,400 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 24.0 of 67.8 of 109.2 of 109.2 of :4 eO 4 Supply Air Ducts Outside Air 80 cfm 108 7 of 69.6 of Heating Coil Supply Fan 2000 cfm ROOMS 70.0 of �% Return Air Ducts `S DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 114.1 / 80.3 of 80.0 / 65.3 of 58.4 / 57.0 of 58.4 / 57.0 of O " Supply Air Ducts Outside Air 80 cfm Cooling Coil Supply Fan 59.0 / 57.2 of 2000 cfm 47.8% R.H. ROOMS 78.6/64.50F 78.0/64.3OF Return Air Ducts I EnergyPro 3:1 By EnergySoft User Number: 3665 Job Number. Page: 20 of 41 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Lunn Residence 5/9/2005 SYSTEM NAME FLOOR AREA HVAC #2 1,473 ENGINEERING CHECKS 1SYSTEM LOAD Number of Systems 1 Heating System Output per System 89,400 Total Output (Btuh) 89,400 Output(Btuh/sgft) 60.7 Cooling System Output per System 58,500 Total Output (Btuh) 58,500 Total Output (Tons) 4.9 Total Output (Btuh/sgft) 39.7 Total Output (sgftlron) 302.2 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.36 Airflow (cfm/Ton) 410.3 Outside Air (%) 5.5 Outside Air (cfm/sgft) 0.07 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts COIL COOLING PEAK I COIL HTG. PEAK CFM ISensiblel Latent I Sensible 1,589 30,716 3,98 545 22,276 0 EATING SYSTEM PSYCHROMETRICS Airstream Tem 1,536 1,114 0 0 110 4,221 2,305 110 5,425 Supply Air Ducts 0 Outside Air 0 11536 1,114 TOTAL SYSTEM LOAD 38,009 6,286 29 929 HVAC EQUIPMENT SELECTION HS26-060/G40UH60C-110 (5) 45,942 6,511 89,400 Total Adjusted System Output 45,942 6,511 89,400 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Note: values above given at ARI conditions ' EATING SYSTEM PSYCHROMETRICS Airstream Tem eratures at Time of Heating Peak 24.0 of 67.0 of 108.4 OF 108.4 OF Supply Air Ducts Outside Air 110 cfm 107.9 OF Heating Coil Supply Fan 2000 cfm ROOMS 70.0 OF 69.5 of Return Air Ducts OOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak '114.1/80.30F 80.7 / 66.2 of 59.4 / 58.0 of 59.4 / 58.0 of Outside Air Supply Air Ducts ' 110 cfm Cooling Coil Supply Fan 60.1 / 58.3 of 2000 cfm ROOMS 50.1% R.H. of 78.0 / 65.0 of 'b 78.7/65.3 Return Air Ducts ' EnergyPro 3.1 By Energysoft User Number. 3665 Job Number. Page:21 of 41 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Lunn Residence 5/9/2005 SYSTEM NAME FLOOR AREA HVAC #3 2,653 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 Heating System Output per System 89,400 Total Output (Btuh) 178,800 Output (Btuh/sgft) 67.4 Cooling System Output per System 58,500 Total Output (Btuh) 117,000 Total Output (Tons) 9.8 Total Output (Btuh/sqft) 44.1 Total Output (sgftrTon) 272.1 Air System CFM per System 2,000 Airflow (cfm) 4,000 Airflow (cfm/sgft) 1.51 Airflow (cfm/Ton) 410.3 Outside Air (%) 5.0 Outside Air (cfm/sqft) 0.08 Note: values above given at ARI conditions 24.0 of 1 Outs 199 cfm 69.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensible Latent I CFM Sensible 3,087 60,181 8,444 1,064 43,796 0 3,009 2,190 0 0 199 7,605 4,174 199 9,772 0 0 3,009 2,190 73,8041 12,618 1 57,9471 HS26-060/G40UH60C-110 (5) 91,604 13,079 178,800 Total Adjusted System Output �91 soa 13,079 178,800 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 67.2 of ® 108.6 of Heating Coil Supply Fan 4000 cfm 108.6 of —� Supply Air Ducts 108.1 of ROOMS 70.0 of Return Air Ducts `S DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 114.1 / 80.3 of 80.5 / 66.1 of 59.2 / 57.9 of 59.2 / 57.9 of Outside Air 0 ' Supply Air Ducts 199 cfm Cooling Coil Supply Fan 59.9 / 58.1 of 4000 cfm 50.0% R.H. ROOMS 78.7/65.2 of 78.0 / 65.0 of h Return Air Ducts `S EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:22 of 41 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Lunn Residence 5/9/2005 SYSTEM NAME FLOOR AREA HVAC #4 414 MEATING SYSTEM 24.0 OF Outside Air 31 cfm 69.5 OF 1 114.1 / 80.3 OF CFM Outside Air Latent 31 cfm 78.6/63.9 °F SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK PEAK CFM Sensible Latent 9�tsible 496 10,760 1,209 221 9,274 0 538 464 0 0 3 1,189 784 31 1,524 0 0 538 464 13,0261 1,9931 11 725 HS26-024/G40UH24A-045X (2) 19,622 1,359 36,000 Total Adjusted System Output 19,622 1,359 36,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am ETRICS (Airstream Tei 67.7 OF 0 109.4 OF Heating Coil ROMETRICS (Airstream T 80.0 / 64.7 OF ratures at Time of Heating Peak) 109.4 of O ';;, Supply Air Ducts Supply Fan 108.8 OF 800 cfm ROOM.? 70.0 OF )% Return Air Ducts `{ watures at Time of Cooling Peak) 57.3 / 55.8 OF 57.3 / 55.8 of Cooling Coil Supply Fa 800 cfm Supply Air Ducts Fan 57.9/56.1OF 45.7% R.H. ROOMS 78.0 / 63.7 OF h Return Air Ducts `S EnergyPro 3.i' By EnergySoft User Number. 3665 Job Number. Page:23 of 41 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Lunn Residence 5/9/2005 SYSTEM NAME FLOOR AREA HVAC #5 536 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 36,000 Total Output (Btuh) 36,000 Output (Btuh/sgft) 67.2 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sqft) 44.8 Total Output (sgftrron) 268.0 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.49 Airflow (cfmrron) 400.0 Outside Air (%) 5.0 Outside Air (cfm/sqft) 0.08 Note: values above given at ARI conditions 24.0 OF 0 Outs 40 cfm 69.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 16,250 2,356 11342 HS26-024/G40UH24A-045X (2) 19,468 1,749 36,000 Total Adjusted System Output 18,468 1,749 36,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm C Jan 12 am 67.2 OF ® 108.9 OF Heating Coil Supply Fan 800 cfm 108.9 OF 311 Supply Air Ducts 108.4 OF ROOMS 70.0 OF k Return Air Ducts `{ DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 114.1 / 80.3 OF 80.5 / 65.3 OF 58.0 / 56.6 OF 58.0 / 56.6 OF 311 vo Supply Air Ducts Outside Air O 40 cfm Cooling Coil Supply Fan 58.8 156.9 OF 800 cfm 47.2% R.H. ROOMS 78.8/64.4 °F 78.0 / 64.2 OF K Return Air Ducts `i EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 24 of 41 1 ROOM LOAD SUMMARY PROJECT NAME The Lunn Residence DATE 5/9/2005 SYSTEM NAME HVAC #1 FLOOR AREA 1,062 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #1 Master Suite 1 1,311 26,824 2,916 1,311 26,824 2,916 448 18,718 t PAGE TOTAL 1,311 26,824 2,916 448 18,718 TOTAL 1 1,311 26,824 2,916 448 18,7181 1 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:25 of 41 ROOM LOAD SUMMARY PROJECT NAME DATE The Lunn Residence 5/9/2005 SYSTEM NAME FLOOR AREA HVAC #2 1,473 1 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:26 of 41 t ROOM LOAD SUMMARY PROJECT NAME 11 The Lunn Residence DATE 5/9/2005 SYSTEM NAME HVAC #3 FLOOR AREA 2,653 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #3 Living Area 1 3,087. 60,181 8,444 3,087 60,181 8,444 1,064 43,796 { PAGE TOTAL 1 3,087 60,181 8,444 1,064 43,796 TOTAL 1 3,087 60,181 8,444 1,064 43,796 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:27 of 41 ROOM LOAD SUMMARY PROJECT NAME The Lunn Residence DATE 5/9/2005 SYSTEM NAME HVAC #4 FLOOR AREA 414 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #4 Bedroom #3 1 496 10,760 1,209 496 10,760 1,209 221 9,274 PAGE TOTAL 1 496 10,760 1,209 221 9,274 TOTAL 1 496 10,760 1,209 221 9,274 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:28 of 41 ROOM LOAD SUMMARY PROJECT NAME The Lunn Residence. DATE 5/9/2005 SYSTEM NAME HVAC #5 FLOOR AREA 536 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #5 Guest Room Upstairs 1 645 13,379 1,402 645 13.379 1,402 205 8,515 EEI- PAGE TOTAL " 645 13,379 1,402 205 8,515 TOTAL a 645 13,379 1,402 205 8,515 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 29 of 41 ROOM HEATING PEAK LOADS ' Project Title Date The Lunn Residence 15/9/2005 Room Information Design Conditions ' Room Name Master Suite Time of Peak Jan 12 am Floor Area 1,062 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF ' Conduction Area U -Value AT OF Btu/hr ' Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 14 323 Infiltration: L 1.001X 1.080 x 1=062 x 10.00 x 0.50 / 60] x 46 = 4 395 Schedule Air Sensible Area Ceiling Height ACH OT Fraction 'F TOTAL HOURLY HEAT LOSS FOR ROOM 18,718 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 30 of 41 1062.0 x x x X x x x X X x x X x X X X X X X x x X- x X x X x x X _. X x x_ x x X x X X x 0.0253 X x x x X x X x x x X X X x x x x x X x x x x x x X X X X X x x x x X x x x X 46.0 = = = = = = — = = = = 1,234 839.0 0.0566 46.0 2,185 192.0 0.4000 46.0 3,533 54.0 0.8000 46.0 1,987 15.0 0.5500 46.0 380 perimeter= 110.0 45.5 5,005 ' Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 14 323 Infiltration: L 1.001X 1.080 x 1=062 x 10.00 x 0.50 / 60] x 46 = 4 395 Schedule Air Sensible Area Ceiling Height ACH OT Fraction 'F TOTAL HOURLY HEAT LOSS FOR ROOM 18,718 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 30 of 41 ROOM HEATING PEAK LOADS ' Project Title Date The Lunn Residence 5/9/2005 Room Information Design Conditions ' Room Name Bed #2 / Media / Game Rm Time of Peak Jan 12 am Floor Area 1,473 Outdoor Dry Bulb Temperature 24 of Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr ' Items shown with an asterisk ('rr) denote conduction through an interior surface to another room. Page Total: — 16 333 Infiltration: II 1.001X 1.080 x 1 473 x 9.75 x 0.50 / 60] x 46 5 943 chedule Air Sensible Area Ceiling Height ACH DT Fraction 'F TOTAL HOURLY HEAT LOSS FOR ROOM 22,276 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 31 of 41 1473.0 x x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0253 x x X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = _ = = 1711 882.7 0.0566 46.0 2.299 80.0 0.8000 46.0 2,944 87.3 0.5500 46.0 2,209 88.0 0.4000 46.0 1,619 perimeter =122.0 45.5 5,551 ' Items shown with an asterisk ('rr) denote conduction through an interior surface to another room. Page Total: — 16 333 Infiltration: II 1.001X 1.080 x 1 473 x 9.75 x 0.50 / 60] x 46 5 943 chedule Air Sensible Area Ceiling Height ACH DT Fraction 'F TOTAL HOURLY HEAT LOSS FOR ROOM 22,276 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 31 of 41 ' ROOM HEATING PEAK LOADS ' Project Title Date The Lunn Residence 5/9/2005 Room Information Design Conditions ' Room Name Living Area Time of Peak .tan 12 am Floor Area 2,653 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Area LI -Value AT of Btu/hr ' Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 30 072 Infiltration: [ 1.001 x 1.080 x 2 653 x 12.50 x 6] x 46 = 13 724 Schedule Alr Sensible Area Ceiling Height ACH DT Fraction 'r TOTAL HOURLY HEAT LOSS FOR ROOM 43,796 ' EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 32 of 41 t 2,653.0 X x X X x x x X X X x X X X x x X x x X x X X X x x x x X x x x X X X x x X X. 0.0253 X x x x X x X X X x X x X X X X x X X X X X x X X X x x X X x x x x x x x X X 46.0 = = = = = = = = = = = 3,082 1,396.8 0.0566 46.0 3,638 375.2 0.4000 46.0 6,904 114.0 0.8000 46.0 4,195 48.0 0.3872 46.0 855 52.0 0.5500 46.0 1,316 108.0 0.5000 46.0 2,484 perimeter = 167.0 45.5 7,598 ' Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 30 072 Infiltration: [ 1.001 x 1.080 x 2 653 x 12.50 x 6] x 46 = 13 724 Schedule Alr Sensible Area Ceiling Height ACH DT Fraction 'r TOTAL HOURLY HEAT LOSS FOR ROOM 43,796 ' EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 32 of 41 t ROOM HEATING PEAK LOADS ' , Project Title Date The Lunn Residence 15/9/2005 Room Information Design Conditions ' Room Name Bedroom #3 Time of Peak Jan 12 am Floor Area 414 Outdoor Dry Bulb Temperature 24 of Indoor Dry Bulb Temperature 70 OF ' Conduction Area U -Value AT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 7 389 Infiltration: [ 1.00 x 1.080 x 414 x 11.00 X1 0.50 / 60] x 46 = 1 885 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,274 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:33 of 41 1 414.0 X X x x x x x x X X x X X X X X" X x x X x X x X x x x x X X X X x X x x x x X 0.0253 X x x X x x x X x X X x x x x x x X X x x X x X x x x x X X x x x x X x x x x 46.0 = = = = = = = = = = = _ 481 498.0 0.0566 46.0 1,297 8.0 0.5500 46.0 202 45.0 0.4000 46.0 828 54.0 0.8000 46.0 1,987 perimeter = 57.0 ® 45.5 2,594 ~ Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 7 389 Infiltration: [ 1.00 x 1.080 x 414 x 11.00 X1 0.50 / 60] x 46 = 1 885 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,274 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:33 of 41 1 ROOM HEATING PEAK LOADS. ' , Project Title Date The Lunn Residence 15/9/2005 Room Information Design Conditions ' Room Name Guest Room Upstairs Time of Peak Jan 12 am Floor Area 536 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr ' Items shown with an asterisk (•rr) denote conduction through an interior surface to another room. Page Total: 6 463 Infiltration: I1 1.001 x 1.080 x 536 x 9.25 x 0.50 / 601 x 46 = 2 052 chedule Air Sensible Area Ceiling Height ACH AT Fraction 'F TOTAL HOURLY HEAT LOSS FOR ROOM 8,515 ' EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:34 of 41 r 500.0 x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x xx x 0.0278 X x x X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 640 36.0 0.0278 0.0 0 536.0 0.0253 46.0 623 764.3 0.0566 46.0 1,991 88.3 0.4000 46.0 1.625 33.4 0.8000 46.0 1,229 20.0 0.3872 46.0 356 ' Items shown with an asterisk (•rr) denote conduction through an interior surface to another room. Page Total: 6 463 Infiltration: I1 1.001 x 1.080 x 536 x 9.25 x 0.50 / 601 x 46 = 2 052 chedule Air Sensible Area Ceiling Height ACH AT Fraction 'F TOTAL HOURLY HEAT LOSS FOR ROOM 8,515 ' EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:34 of 41 r RESIDENTIAL ROOM COOLING LOAD SUMMARY The Lunn Residence 5/9/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area X U -Value Master Suite 780E 115°F 370E DETD1 X 56.0 X 35.6 X 37.0 X 37.0 X 37.0 X X X X Btu/hr 1,502 1,691 2,842 1,598 305 1. Design Equivalent Temperature Difference (DETD) Page Total 7 938 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr FxdGlsWdw N -(East Ernchl) (13) (East) FxdGlsWdw O (East) FxdGlsWdw P (South) FxdGlsWdw (Q) (South) FxdGlsWdw R (South) CsmntWdw S West FxdGlsWdw T West FxdGlsWdw U (West) 15+ 27.0 ( 0.0 X X X x X x x1 x x x 1 + + + + + + + + + 27.0 x x x x X X x x X x 73 )X ) x ) X x X X ) X )x 0.390 = = = = = = = = = = 768 ( 0.0 1 54.0 73 0.657 2,589 ( 0.0 15+ 27.0 73 0.390 768 ( 0.0 15 21.0 32)x 0.390 262 ( 0.0 15 60.0 32) 0.390 748 ( 0.0 15 21.0 32) 0.390 262 ( 0.0 15.0 73) 0.323 354 ( 0.0 1 33.0 73)X 0.390 939 ( 0.0 1 3.0 7 0.390 85 ( Page Total s 77a Sched. Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,062 x 0.500 Watts/sgft x 3.41J Btuh/Watt = 1,812 Occupants 1.00 x 1,062 x 250 Btuh/occ. / 200 sgft/occ. = 1,328 Receptacle 1.00 x 1,062 x 1.500 Watts/sgft x 3.413 BtuhMatt = 5,437 Process 1.00 x 1,062 x 0.000 Waftslsgft x 3.41 BtuhMatt = 0 Infiltration:tQ0 x Q$0 x ,Q6 x 1.ap-o x 0_50 / 60] E_37J = :�35 Schedule Air Sensible Area Ceiling Height ACH z2sT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 26824 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occu ants1.00 x 1 062 x 200 Btuhlocc. / 200 sgft/occ. = 1 062 Receptacle 1.00 x 1 062 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = Process 1.00 x 1 062 x 0.000 Watts/sgft x 3.41 Btuh/Watt = Infiltration: [ 1.00 x 4.B401 x 1 062 x 10.00 x 0.50 / 60] 0.00433 = 1 854 Schedule Air Latent Area Ceiling Height ACH LAW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,916 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 35 of 41 RESIDENTIAL ROOM COOLING LOAD SUMMARY ' The Lunn Residence 5/9/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Bed #2 / Media / Game Rm 780F 115°F 37°F Conduction Area U -Value DETDBtu/hr X X X X X X X x X X _((North) 56.0 = 2,083 X CsmntWdw (C1) 35.6 = 1,779 X (East) 37.0 = 2,368 X FxdGISWdW W Abv. 37.0 = 1,777 X 0.657 37.0 = 1.302 X X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 9.3091 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FrnchDr Z) _((North) CsmntWdw_(B1) (North) FrnchDr 16 _ North CsmntWdw (C1) _ North CsmntWdw (D1) (East) CsmntWdw (E1_) (East) CsmntWdw F1 (East) FxdGlsWdw V (West) FxdGISWdW W Abv. (West) FXdGIsWdW X West ( 0.0 X X X x x x x x x x 1 + + + + + + + + 40.0 X X x X x X X X X X 15 ) X )X X x x x ) x x 0.657 = = = = = = = = = = 394 ( 0.0 15+ 16.5 15 0.323 80 ( 0.0 14,+ 40.0 15) 0.657 394 ( 0.0 1 16.5 15) 0.323 80 (-0.0 1 11.3 73) 0.323 266 ( 0.0 1 14.0 73)X 0.323 330 ( 0.0 15 6.0 73)X 0.323 141 ( 0.0 1 30.0 73) 0.390 853 ( 0.0 15 28.0 7 0.390 796 ( 0.0 1 30.0 73) 0.390 853 Sched. Page Total 4.1891 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,473 x 0.500 Watts/sgft x 3.412 Btuh/Waft = 2,514 Occupants 1.00 X 1,473 X 250 Btuh/occ. / 200 sgft/occ. = 1,841 Receptacle 1.00 x 1,473 x 1.500 Watts/sgft X 3.413 Btuh/Waft = 7,541 Process 1.00 x 1,473 x 0.000 Wafts�/sgfttx 3.41 Btuh/Waft = 0 Infiltration: = o0 x 1.080 x E: 47 x X9,51 x L_0.�o1 / 60] E=-3 _ Schedule Air Sensible Area Ceiling Height ACH nsT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 30,7161 ' Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 473 x 200 Btuh/OCC. / 200 sqft/occ. = 1 473 ' Receptacle 1.00 x 1 473 x 0.000 Watts/sgft X 3.41 Btuh/Waft = 0 Process 1.00 x 1 473 x 0.000 Watts/sgft x 3.41 Btuh[Waft = 0 I Infiltration: 1 1 -ool x 4.8401 x 1 47 x 9.75 x 0.50 / 60] 0.00433 = 2 508 chedule Alr Latent Area Ceiling Height ACH ow Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,981 ' EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 36 of 41 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Lunn Residence 5/9/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Bed #2 / Media / Game Rm 78°F 115°F 370F Conduction Area U -Value DETD' Btu/hr 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Solar Gain Orientation Area SGF CsmntWdw Y _(West) ( 0.0 x 1 + CsmntWduv (A1) (West) ( 0.0 x 1 + ( X + ( x + ( x + ( x + ( x + ( x + ( x + ( x + Sched. Page Total 542 ' Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,473 x 0.500 Watts/sgft x 3.41 BtuhMatt = 2,514 Occupants 1.00 X 1,473 X 250 Btuh/occ. / 200 sgft/occ. = 1,841 ' Receptacle 1.00 x 1,473 x 1.500 Watts/sgft x 3.413 Btuh[Watt = 7,541 Process 1.00 x 1,473 x 0.000 Watts/sgft x 3.41Bt�BtuhhfWatt 0 Infiltration: 1_l) x 08 x 1,473 x 9.Z5 x .50 / 60] L 37J = Z8 ' Schedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 30,7161 ' Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 473 X 200 Btuh/OCC. / 200 sgft/occ. = 1 473 ' Receptacle 1.00 X 1 473 X 0.000 Watts/sgft x 3.41 BtuhMatt = 0 Process 1.00 x 1 473 x 0.000 Watts/sgft x 3.41 BtuhNVatt = 0 Infiltration: 1.00 x 4 840 x 1 47 x 9.75 x 0.50 / 60] 0.00433 = 2 508 Schedule Air Latent Area Ceiling Height ACH pyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,981 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 37 of 41 . Page Total 0 Unshaded Area SGF SC Btu/hr 8.0 x 73 )X 0.323 = 189 15.0 X 73 ) X 0.323 = 354 X )x = X )X = X )X = X )x = X )x = X )x = )x X = Sched. Page Total 542 ' Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,473 x 0.500 Watts/sgft x 3.41 BtuhMatt = 2,514 Occupants 1.00 X 1,473 X 250 Btuh/occ. / 200 sgft/occ. = 1,841 ' Receptacle 1.00 x 1,473 x 1.500 Watts/sgft x 3.413 Btuh[Watt = 7,541 Process 1.00 x 1,473 x 0.000 Watts/sgft x 3.41Bt�BtuhhfWatt 0 Infiltration: 1_l) x 08 x 1,473 x 9.Z5 x .50 / 60] L 37J = Z8 ' Schedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 30,7161 ' Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 473 X 200 Btuh/OCC. / 200 sgft/occ. = 1 473 ' Receptacle 1.00 X 1 473 X 0.000 Watts/sgft x 3.41 BtuhMatt = 0 Process 1.00 x 1 473 x 0.000 Watts/sgft x 3.41 BtuhNVatt = 0 Infiltration: 1.00 x 4 840 x 1 47 x 9.75 x 0.50 / 60] 0.00433 = 2 508 Schedule Air Latent Area Ceiling Height ACH pyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,981 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 37 of 41 RESIDENTIAL ROOM COOLING LOAD SUMMARY ' The Lunn Residence 5/9/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Living Area 78°F 115°F 370E Conduction Area U -Value DETD 1 Btu/hr X X X X X X X x X X X X X X X X 56.0 = = = = = =1058 = 3,751 35.6 2,816 37.0 5,553 37.0 3,374 35.6 662 37.0 South 37.0 1 1.998 X X 1. Design Equivalent Temperature Difference (DETD) Page Total 19 212 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxdGlsWdw A (North) SwngGlsEntryD (North) FxdGlsWdw B North CsmntWdw G East FrnchDr (9) (Southeast) FxdGlsWdw K (South) FxdGlsWdw L Abv. South FxdGlsWdw 11 (South) FXdGISWdw (M) Sid GIsDr 12 (South) South ( 0.0 x x x x x x x x x x 1 + + + + + + + + + 57.0 x x x x x x x x x x 15 )X )X x x x x x ) x 0.390 = = = = = = = = = 333 ( 0.0 15 60.0 15 0.657 591 ( 0.0 1 57.0 15) 0.390 333 ( 0.0 1 24.0 73) 0.323 566 ( 0.0 1 27.0 62) 0.657 1,099 ( 0.0 1 82.2 32)X 0.390 1,025 ( 0.0 15 47.0 32) 0.390 586 ( 48.5 15 0.0 32)X 0.390 283 ( 48.5 151+ 0.0 32) 0.390- 283 ( 108.0 1 0.0 32 0.401 649 ' Sched. Page Total 5.7491 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 2,653 x 0.500 Watts/sgft x 3.413 Btuh/Watt - 4,527 Occupants 1.00 x 2,653 x 250 Btuh/occ. / 200 sqft/occ. = 3,316 Receptacle 1.00 x 2,653 x 1.500 Watts/sgft x 3.413 Btuh/Watt _ 13,582 Process 1.00 x 2,653 x 0.000 Wattfts/sgftt�x 3.412� BtuhhfWatt 0 Infiltration: �� x 8o x 2,683 x 50 x E::] 1 / 60] �37J =m ' Schedule Air Sensible Area Ceiling Height ACH nsT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 60181 ' Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x2 653 x 200 Btuh/occ. / 200 sgft/occ. = 2 653 ' Receptacle 1.00 x 2 653 x 0.000 Wafts/sqft x 3.41 Btuh[Watt = Process 1.00 x 2653 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: cnedule X Air Latent x Area x Ceiling Height x ACH 50 / 60] Z\tON0433 = 5 791 ' Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 8,444 ' EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 38 of 41 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Lunn Residence 5/9/2005 Project Title Date Room Name Living Area Design Indoor Dry Bulb Temperature: - 78oF Design Outdoor Dry Bulb Temperature: 115 F Design Temperature Difference: 370F Conduction Area U -Value DETD 1 Btu/hr X = X — X — X — X = X = X = X = X = 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr FrnchDr 10 (Southwest) ( 0.0 X 1 + 27.0 x 62)X 0.657 = 1,099 CsmntWdw_(C. (West) ( 0.0 x 1 + 14.0 x 73 ) x 0.323 = 330 FxdGlsWdw D _(West) ( 0.0 x 1 + 35.0 x 73 ) x 0.390 = 995 CsmntWdw E ( 0.0 x 1 + 14.0 x 73) x 0.323 = 330 _(West) ( x + x )x = ( x + X )x = ( x + x )x = ( x + x )x = ( x + x )x = Sched. Page Total 2.7551 'Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 2,653 x 0.500 Watts/sqft x 3.41 Btuh/Watt = 4,527 Occupants 1.00 X 2,653 X 250 Btuh/occ. / 200 sgft/occ. = 3,316 Receptacle 1.00 x 2,653 x 1.500 Watts/sgft x 3.413 Btuh/Watt _ 13,582 Process 1.00 x 2,653 x �. 0.000 Watts/sgft x 3.41�BtuhfWatt 0 Infiltration: [ Lo0 x 80 x 65 x —t2 X01 x / 60] �-7 = o- ' Schedule Air Sensible Area Ceiling Height ACH Z -\T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 60181 ' Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 2,653 X 200 Btuh/OCC. / 200 sgftlocc. = 2 653 ' Receptacle 1.00 x 2 653 x 0.000 Watts/sgft x 3.41 Btuh/Watt = o Process 1.00 x 2.65 x 0.000 Watts/sgft x 3.41 Btuh/Watt = o Infiltration: [ 1 01 x 4 ' nt x 2 653 . x Heigh x 60] 0.00433 = 5 791 Schedule Alr Latent Area Ceiling Height ACH DW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 8,444 ' EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page:39 of 41 RESIDENTIAL ROOM COOLING LOAD SUMMARY ' The Lunn Residence 5/9/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-38 Roof (R.38.2x14.1 Area U -Value 414. DETD 1 x 56.0 x 35.6 x 37.0 x 37.0 X 37.0 x x x x Bedroom #3 780F 115°F 37°F Btu/hr 585 1,004 = 163 666 1,598 1. Design Equivalent Temperature Difference (DETD) Page Total 4 017 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr CsmntWdw H (East) ( 0.0 x 15,+ 8.0 x 73)x 0.323 = 189 F-td.GlsWdw-(l) (South) ( 0.0 X 1 + 22.5 X 32)x 0.390 = 281 FrnchDr 8 (South) ( 0.0 x 1 + 54.0 x 32)x 0.657 = 1,135 FxdGlsWdw J (South) ( 0.0 x 15 + 22.5 x 32) x 0.390 = 281 ( x + x -) x = ( x + X )X = ( x + X )x = ( x + X )X = ( X + X )X = Sched. Page Total 1,885 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 414 X 0.500 Wafts/sqft x 3.41 Btuh/Waft = 706 Occupants 1.00 X 414 X 250 Btuh/occ. / 200 sgft/occ. = 518 Receptacle 1.00 x 414 x 1.500 Wafts/sgft x 3.413 Btuh/Waft = 2,119 Process 1.00 x 414 x 0.000 Wafts/sqft x 3.412 BtuhlWaft = 0 Infiltration: [ LQO x 1Q8_ x.4L4 x 'L1.Q0 xQ.50 / 60]3.7 = 516 Schedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,760 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 414 x 200 Btuh/occ. / 200 sgft/occ. = 414 ' Receptacle 1.00 x 414 x 0.000 Watts/sqft x 3.41 Btuh/Waft = 0 Process f 1.00 x 414 x 0.000 Watts/sqft x 3.41 Btuh[Waft = 0 Infiltration: I 1.00 x 4.840 x 414 x 11.00 x 0.50 / 60] 0.00433 795 chadule Air Latent Area Ceiling Height ACH �W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,209 1 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 40 of 41 RESIDENTIAL ROOM COOLING LOAD SUMMARY The Lunn Residence 5/9/2005 Project Title Date Room Name Guest Room Upstairs Design Indoor Dry Bulb Temperature: 780F Design Outdoor Dry Bulb Temperature: 115 Design Temperature Difference: 370 F Conduction Area U -Value DETD' X 27.0 X 0.0 X 56.0 X 35.6 X 37.0 X 37.0 X 35.6 X X Btu/hr 376 0 758 1,54 1,307 989 276 1. Design Equivalent Temperature Difference (DETD) Page Total 5 245 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxdGlsWdw (M1) -(North F_rn.chDr_(3.9) (North) FxdGlsWdw (N1) (North FxdGlsWdw 01 East FxdGlsWdw (P1) (East) FXdGIsWdW H1 (South) FxdGlsWdw J1 (West) FxdGISWdW K1 West FxdGISWdW L1 (West) 15 13.3 ( 0.0 X1 x x x x x x x X x + + + + + + + + + # 13.3 x X X x X x x x x x 15 )X ) X x x X x ) X )X 0.390 = = = = = = = = = = 78 ( 0.0 1 33.4 15 0.657 329 ( 0.0 15 13.3 15)X 0.390 78 ( 0.0 1 5.3 73) 0.390 151 ( 0.0 1 5.3 73) 0.390 151 0.0 1 5.3 32) 0.390 66 ( 0.0 1 10.4 73) 0.390 296 ( 0.0 1 25.0 73)X 0.390 711 ( 0.0 1 10.4 7 0.390 296 ( Sched. Page Total 2 155 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 536 X 0.500 Watts/sgft x 3.41 Btuh/Watt = 915 Occupants 1.00 X 536 X 250 Btuh/occ. / 200 sgft/occ. = 670 Receptacle 1.00 x 536 x 1.500 Watts/sgft x 3.413 Btuh/Watt = 2,744 Process ��1.00x 536 xx 0.000 Wafts/sgft .x 3.41 Btuh/Watt = 00 Infiltration: 1.00 x 1 10x�9J A8x X 536 x 9.2 x E_0_5 / 60] =3IJ Schedule Air sensible Area Ceiling Height ACH �T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,379 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants1.00 x 536 x 200 Btuh/occ. / 200 sgft/occ. = 536 Receptacle 1.00 x 536 x 0.000 Watts/sgft x 3.41 Btuh/Waft = 0 Process 1.00 x 536 x 0.000 Wafts/sqft x 3.413 BtuhlWatt = 0 Infiltration: [ 1.00 x 4840 x 53 x Height x 60] 0.00433 = 866 Schedule Air Latent Area Ceiling Height ACH "-\W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,402 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page:41 of 41