Loading...
04-4605 (SFD)i ce4 �F �wQ611�rw x 1504 :�ALLE TAMPICO, ITA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT (760).777-7012 FAX (760) 777-7011 INSPECTION REQUESTS (7.60) 777-7153 ' BUILDING PERMIT er Application description Property Zoning Application valuation Owner LENNAR HOMES OF CALIFORNIA 78401 HIGHWAY 111, STE C LA QUINTA, CA LA QUINTA CA 92253 04-00004605 Date' 7/09/04 44795 VIA MIRABEL 604-032-999-34• -305212- DWELLING — SINGLE FAMILY DETACHED LOW DENSITY RESIDENTIAL 169528 Contractor ------------------------ LENNAR HOMES OF CALIFORNIA INC 78401 HIGHWAY 111, SUITE C LA QUINTA CA 92253 Qty Unit Charge Per Extension WCC: OLD REPUBLIC IN WC: MWC10877600 11/01/04 CSLB: 728102 09/30/04 CCC: B -------------------------- Structure Information ------------------------- Construction Type . . . .. TYPE V - NON RATED Occupancy Type . . DWELLG/LQDGING/CONG <=10 Flood Zone NON -AO FLOOD ZONE Other struct info CODE EDITION 2001 CRC FIRE SPRINKLERS NO GARAGE SQ FTG 462:00 PATIO SQ FTG 488.00 NUMBER OF UNITS 1.00 FIRST FLOOR SQ FTG --------=-------------- 2692.00 -------------------------=--------------------------- Permit . . . . BUILDING PERMIT Additional desc Permit Fee . . . . 884.50 Plan Check Fee 143.73 .Issue Date . . . . Valuation . . . . 169528 Qty Unit Charge Per Extension BASE FEE 639.50 70.00 3.5000 ----------------------------------------------------------------------------- THOU BLDG 100,001-500,000 245.00 Permit . . . . MECHANICAL Additional desc Permit Fee 83.50 Plan Check'Fee 5.22 Issue Date Valuation . . . . 0 Qty Unit Charge Per Extension ` Y � P.O. Box 1504 • VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 4INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: Applicant: Applicant's Mailing Address: S or c� S4- Lic. No.: 36 t$UILUINU PERMIT DECLARATIONS Date: 8 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my Licis in full force and effect. -7`14, cense Class --License No. J - OWNER -BUILDER •DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date WORKERS' COMPENSATION DECLARATION I. hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance �j of the work for which this permit is issued. �l I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is /i ed.�jtAy rke cow nsation insurance carrie a dp�Ii' nymge r Cartier �I,((,�((// Mr 7,_ � �licy, Number _ I certify 1hat, ifi the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. ate � Q pp�A licant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lenders Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating •to building construction, /and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. , ate U GIP v zgna/tura (Applicant or Agent): &14a� Page 2 Application Number . . . 04-00004605 Date 7/09/04 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE _<=100K 18.00 2:00 9.0000 EA `MECH B/C <=3HP/100K BTU- 18.00 4.00 6.5000 EA MECH VENT FAN 26.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . .ELEC-NEW RESIDENTIAL - Additional desc Permit Fee . . . . 118.46 Plan Check Fee 7.41 Issue`Date Valuation 0 Qty Unit Charge Per. Extension. BASE FEE 15.00 2692..00 .0350 ELEC NEW RES = 1 OR 2 FAMILY 94.22 462.00 .0200 ELEC.GARAGE OR NON-RESIDENTIAL 9.24 Permit . . . . . PLUMBING' Additional desc Permit Fee 189.00 Plan Check Fee 11.81 Issue -Date . . . . Valuation 0 Qty Unit, Charge- Per Extension BASE.FEE 15.00 20.00 6.0000 EA PLB FIXTURE 120.00 1.00 15.0000 EA 'PLB BUILDING SEWER 15.00 1.00 -7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 6.00 .7500 EA: PLB GAS PIPE >=5 4.50 1.00 15.0000 EA PLB GAS. METER 15.00 Permit GRADING PERMIT Additional" desc .. Permit Fee . . . 15.00 Plan Check -Fee .00 Issue Date - Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments .. SFD - LOT 34. 'PLAN 1Z. PERMIT DOES NOT Page 3 Application Number .. 04-00004605 Date 7/09/04 --------------------------------------------------------------------------- Special Notes and Comments INCLUDE BLOCK WALLS, POOL, SPA OR DRIVEWAY APPROACH. 75% PLAN CHECK FEE REDUCTION APPLIED FOR -MULTIPLE ISSUANCE OF SAME PLAN TYPE. -------------------------------------------------------------------- Other Fees . . . . ART IN PUBLIC. PLACES -RES' .00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 14.37 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN, CHECK FEE 00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC- RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 16.95 DIF STREET MAINT. FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary, Charged Pai-d Credited - Due Permit Fee Total 1290.46 .00 .00 1290.46 Plan Check Total 168.17 .00 .00 168.17 Other Fee Total 2436.32 00 .00 2436.32 Grand Total 3894.95 .00. .00 3894.95 PREPARED 1/20/11, 10:43:27 INSPECTION HISTORY REPORT PAGE 1 PROGRAM BP521L 0/00/00 THRU 0/00/00 CITY OF LA QUINTA ' ------------------------------------------------------------------------------------------------------------------------------------ APPLICATION PROPERTY ADDRESS APN Alternate ID ' STRUCTR ----------------------`----`-------------------------------------------------------------------------------------------------=------ PERMIT INSPECTION RESULT-DATE/STATUS. INSPECTOR .. 04 00004605 44795 VIA MIRABEL 604-032-999-34 -305212- -"`000 000- B001 00 --BUILDING PERMIT _ 120 0001 FOOTINGS 10/27/04 APPROVED TM• 000 000• B001 00 BUILDING PERMIT 125 0001 SLAB 11/08/04 APPROVED TM ' 000 000 B001 00 BUILDING PERMIT" 135 0001 ROOF NAIL 12/09/04 APPROVED TM 000 000 B001 00 BUILDING PERMIT 140 0001 OKAY TO WRAP 12/09/04 APPROVED 'TM 000 000 B001 00 BUILDING PERMIT 145 0,001 FRAMING 12/09/04 APPROVED" TM - 000 000 B001 00 BUILDING PERMIT - 150 0001 INSULATION 2/03/05 APPROVED - TM - 000 000 B001.00 BUILDING PERMIT 160 0001 DRYWALL NAIL.• 2/03/05 APPROVED TM •- - .- 000 000 B001 00 BUILDING PERMIT 155 0001 LATH 2/16/05 APPROVED TM - - 1-00-0 -000.. _ B001._00 BUILDING ,PERMIT, __ , _ _ -. - ,_ _199 -0001-FINAL 4/18/05 APPROVED1. - 000 000 E01..00 ELEC-NEW RESIDENTIAL -� 310, 0001 ROUGH .ELECTRICAL. - - 12/09/04 APPROVED _ TM 000 000 E01 00 ELEC-NEW-RESIDENTIAL 315. 0001 TEMP USE OF PERMANENT POW 3/01/05 APPROVED - TM - 000 000 `E01 00 ELEC-NEW RESIDENTIAL 399 —0001 ELECTRICAL FINAL - 4/18/05 APPROVED -, _ TM " 000 000, GP 00 GRADING PERMIT 197 "0001 GRADING FINAL 4/18/05 APPROVED ' .000 000 M01 00 MECHANICAL - 405 0001 ROUGH MECHANICAL - 12/09/04 APPROVED - -_ 000 000 -M01 00 MECHANICAL - -" _499 0001 MECHANICAL FINAL--- .:-° -`-4/18/05 APPROVED.--•'- "• -`TM- ' 000 000 P01- 00 PLUMBING ." 200 0001 UNDERGROUND PLUMBING. 10/21/64 APPROVED' - DC. - 000 000 ..P01 00 PLUMBING. -. 210 0001 SEWER CONNECTION' - 10/23/04 APPROVED DC " 000 000 P01 00 PLUMBING - 230 0001 ROUGH PLUMBING 12/09/04 APPROVED TM '. 000 000 P01 00 PLUMBING 245 0001 SHOWER PAN "12/09/04 APPROVED ,. TM_ 000 000 P01 00 PLUMBING 235. 0001 GAS LINE / GAS TEST 3/01/05 APPROVED - TM " 000.000 P01. 00 PLUMBING. .. - - 299 0001 PLUMBING FINAL 4/18/05'APPROVED TM -- ,. Certificate of Insulation Your home has been insulated with Johns Manville Fibealass insulation products, which are designed for today's safety standards and tomorrow/s energy requirements. v Fiberglass is inorganic and therefore permanently noncombusfble, so it does not have to be treated v with fire -retardant chemicals that will likely lose their effectiveness over time. It has not been treated with chemicals that can corrode wiring or metal. Fiberglass will not absorb moisture nor will it r settle over time as may other insulation materials_ D This also certifies that insulation have been professionally installed in this home to provide the follo'.ving thermal performance. Lennar Momes,'lnc. Job Name: La Quints Del Oro Tract: 30521 Plan# iZ & Casitas Phase: 6 Lot No: 34 Job Address:. SFR -44-795 Via Mlarabel, La Quinta, CA Ceiling Area: R-38 blown and batt insu'ation Garage Ceiling: '"Non -Access: ' With Living Above . & Sloping Areas, �r C L Exterior Walls R-13 bats insulation Overhangs. Access Attic: IL n With Living Above E Between Floors: Interior Walls: Subcontractor... 0 J Insulation, Inc. 72-227 Adelaid St: Thousand Palms, CA 92278 :. IL n _ Signed: Mike Dickerson, General Manager - Paim 'Springs Division R -means resistance to heat flow. The higher the R -value, the greater the insulating power. U Ask your builder for the fact sheet on R -values. Keep this certificate with your other U valued papers. If you ever sell this home, this certificate should be passed on to the buyer. L IL _. _ d 4� S v . CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7) La Quinta Del Oro 4/14/2005 ✓ �� (0 CF -4R �C! Project Title Date �-'� ��5 1 �. ► r��� Lennar Project Address Builder Name' Builder Contact Tel hone Plan Number William Henson 760- - HERS R Telephone Sample Group Number Certifying Signature Date `Sample House Number Fi :BCl TestingHERS Provider: CalCer - r Street Address: PO Box -50575 City/State/Zip: Phoenix, AZ 85076 Copies to: Builder, HERS Provider HERS RATER COMPL ANCE STATEMENT The house was: ❑ Tested Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. ❑ The installer has provided a copy of CF -6R (Installation Certificate. ❑ Distribution system is fully ducted (i.e.; does not use building cavities as plenums or platform returns in lieu of ducts) ❑ Where cloth backed, rubber adhesive duct tape is installed; mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. ❑ MINIMU!VI REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results,(Maximum 6%`Duct Leakage) - Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM " If fan.flow is calculated as 400cfm/ton x number of tons enter calculated value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) Check Box for Pass or Fail (Pass=6% or less) ❑ ❑ • Pass Fail ❑ THERMOSTATIC EXPANSION VALVE (TXV) ❑ Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection ❑ ❑ .Yes is'a pass Pass Fail ❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT 1 ❑ Yes - ❑ No ACCA Manual. D Design requirements have been met (rater has verified that actual installation matches values in CF -IR and design on plan. 2 ❑ Yes ❑ No TXVis installed or Fan flow has been verified. If no TXV, verified fan flow matches design from CF -IR. Measured Fan Flow ❑ ❑ F - Yes for both 1 and 2 is a Pass Pass Fail L,ompuance forms August 2001 A-16