04-4605 (SFD)i
ce4 �F �wQ611�rw
x 1504
:�ALLE TAMPICO,
ITA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
(760).777-7012
FAX (760) 777-7011
INSPECTION REQUESTS (7.60) 777-7153
' BUILDING PERMIT
er
Application description
Property Zoning
Application valuation
Owner
LENNAR HOMES OF CALIFORNIA
78401 HIGHWAY 111, STE C
LA QUINTA, CA
LA QUINTA CA 92253
04-00004605 Date' 7/09/04
44795 VIA MIRABEL
604-032-999-34• -305212-
DWELLING — SINGLE FAMILY DETACHED
LOW DENSITY RESIDENTIAL
169528
Contractor
------------------------
LENNAR HOMES OF CALIFORNIA INC
78401 HIGHWAY 111, SUITE C
LA QUINTA CA 92253
Qty Unit Charge Per
Extension
WCC: OLD REPUBLIC
IN
WC: MWC10877600
11/01/04
CSLB: 728102
09/30/04
CCC: B
--------------------------
Structure Information -------------------------
Construction Type . .
. .. TYPE V - NON RATED
Occupancy Type . .
DWELLG/LQDGING/CONG <=10
Flood Zone
NON -AO FLOOD ZONE
Other struct info
CODE EDITION 2001
CRC
FIRE SPRINKLERS NO
GARAGE SQ FTG
462:00
PATIO SQ FTG
488.00
NUMBER OF UNITS
1.00
FIRST FLOOR SQ FTG
--------=--------------
2692.00
-------------------------=---------------------------
Permit . . . .
BUILDING PERMIT
Additional desc
Permit Fee . . . .
884.50 Plan Check Fee
143.73
.Issue Date . . . .
Valuation . . . .
169528
Qty Unit Charge
Per
Extension
BASE FEE
639.50
70.00 3.5000
-----------------------------------------------------------------------------
THOU BLDG 100,001-500,000
245.00
Permit . . . .
MECHANICAL
Additional desc
Permit Fee
83.50 Plan Check'Fee
5.22
Issue Date
Valuation . . . .
0
Qty Unit Charge Per
Extension
` Y �
P.O. Box 1504 • VOICE (760) 777-7012
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 4INSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT
Application Number:
Applicant:
Applicant's Mailing Address:
S
or
c�
S4-
Lic. No.: 36
t$UILUINU PERMIT DECLARATIONS
Date: 8
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
Code, and my Licis in full force and effect. -7`14,
cense Class --License No.
J -
OWNER -BUILDER •DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
U I am exempt under Sec. , BA P.C. for this reason
Date
WORKERS' COMPENSATION DECLARATION
I. hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
�j of the work for which this permit is issued.
�l I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
/i ed.�jtAy rke cow nsation insurance carrie a dp�Ii' nymge r
Cartier �I,((,�((// Mr 7,_ � �licy, Number
_ I certify 1hat, ifi the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with those provisions.
ate �
Q pp�A licant
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name
Lenders Address
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating •to building
construction,
/and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes.
, ate U GIP v zgna/tura (Applicant or Agent): &14a�
Page
2
Application Number
.
. . 04-00004605 Date
7/09/04
Qty Unit
Charge
Per
Extension
BASE FEE
15.00
2.00
9.0000
EA MECH FURNACE _<=100K
18.00
2:00
9.0000
EA `MECH B/C <=3HP/100K BTU-
18.00
4.00
6.5000
EA MECH VENT FAN
26.00
1.00
6.5000
EA MECH EXHAUST HOOD
6.50
Permit . .
. .ELEC-NEW
RESIDENTIAL -
Additional desc
Permit Fee .
. . .
118.46 Plan Check Fee
7.41
Issue`Date
Valuation
0
Qty Unit
Charge
Per.
Extension.
BASE FEE
15.00
2692..00
.0350
ELEC NEW RES = 1 OR 2 FAMILY
94.22
462.00
.0200
ELEC.GARAGE OR NON-RESIDENTIAL
9.24
Permit . . . .
.
PLUMBING'
Additional desc
Permit Fee
189.00 Plan Check Fee
11.81
Issue -Date .
. . .
Valuation
0
Qty Unit,
Charge-
Per
Extension
BASE.FEE
15.00
20.00
6.0000
EA PLB FIXTURE
120.00
1.00
15.0000
EA 'PLB BUILDING SEWER
15.00
1.00
-7.5000
EA PLB WATER HEATER/VENT
7.50
1.00
3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00
9.0000
EA PLB LAWN SPRINKLER SYSTEM
9.00
6.00
.7500
EA: PLB GAS PIPE >=5
4.50
1.00
15.0000
EA PLB GAS. METER
15.00
Permit
GRADING PERMIT
Additional" desc
..
Permit Fee .
. .
15.00 Plan Check -Fee
.00
Issue Date -
Valuation . . . .
0
Qty Unit
Charge
Per
Extension
BASE FEE
15.00
----------------------------------------------------------------------------
Special Notes
and Comments ..
SFD - LOT 34. 'PLAN
1Z.
PERMIT DOES NOT
Page
3
Application Number
..
04-00004605 Date
7/09/04
---------------------------------------------------------------------------
Special Notes and
Comments
INCLUDE BLOCK WALLS,
POOL, SPA
OR
DRIVEWAY APPROACH.
75% PLAN CHECK FEE
REDUCTION APPLIED
FOR -MULTIPLE
ISSUANCE
OF SAME PLAN TYPE.
--------------------------------------------------------------------
Other Fees . . .
.
ART IN PUBLIC. PLACES -RES'
.00
DIF COMMUNITY CENTERS -RES
97.00
DIF CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE
14.37
DIF FIRE PROTECTION -RES
97.00
GRADING PLAN, CHECK FEE
00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC- RES
5.00
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI) - RES
16.95
DIF STREET MAINT. FAC -RES
15.00
DIF TRANSPORTATION - RES
1098.00
Fee summary,
Charged
Pai-d Credited -
Due
Permit Fee Total
1290.46
.00 .00
1290.46
Plan Check Total
168.17
.00 .00
168.17
Other Fee Total
2436.32
00 .00
2436.32
Grand Total
3894.95
.00. .00
3894.95
PREPARED
1/20/11,
10:43:27
INSPECTION HISTORY REPORT
PAGE 1
PROGRAM
BP521L
0/00/00 THRU
0/00/00
CITY OF
LA QUINTA
'
------------------------------------------------------------------------------------------------------------------------------------
APPLICATION
PROPERTY
ADDRESS
APN
Alternate ID
'
STRUCTR
----------------------`----`-------------------------------------------------------------------------------------------------=------
PERMIT
INSPECTION
RESULT-DATE/STATUS.
INSPECTOR
..
04 00004605
44795
VIA MIRABEL
604-032-999-34
-305212-
-"`000
000-
B001
00
--BUILDING
PERMIT
_ 120
0001
FOOTINGS
10/27/04
APPROVED
TM•
000
000•
B001
00
BUILDING
PERMIT
125
0001
SLAB
11/08/04
APPROVED
TM '
000
000
B001
00
BUILDING
PERMIT"
135
0001
ROOF NAIL
12/09/04
APPROVED
TM
000
000
B001
00
BUILDING
PERMIT
140
0001
OKAY TO WRAP
12/09/04
APPROVED
'TM
000
000
B001
00
BUILDING
PERMIT
145
0,001
FRAMING
12/09/04
APPROVED"
TM -
000
000
B001
00
BUILDING
PERMIT -
150
0001
INSULATION
2/03/05
APPROVED -
TM -
000
000
B001.00
BUILDING
PERMIT
160
0001
DRYWALL NAIL.•
2/03/05
APPROVED
TM •- -
.- 000
000
B001
00
BUILDING
PERMIT
155
0001
LATH
2/16/05
APPROVED
TM - -
1-00-0 -000..
_ B001._00
BUILDING
,PERMIT, __ , _ _
-. - ,_ _199
-0001-FINAL
4/18/05
APPROVED1.
-
000
000
E01..00
ELEC-NEW
RESIDENTIAL -�
310,
0001
ROUGH .ELECTRICAL. -
- 12/09/04
APPROVED
_ TM
000
000
E01
00
ELEC-NEW-RESIDENTIAL
315.
0001
TEMP USE OF PERMANENT
POW 3/01/05
APPROVED
- TM
- 000
000
`E01
00
ELEC-NEW
RESIDENTIAL
399
—0001
ELECTRICAL FINAL
- 4/18/05
APPROVED
-, _ TM
" 000
000,
GP
00
GRADING
PERMIT
197
"0001
GRADING FINAL
4/18/05
APPROVED
' .000
000
M01
00
MECHANICAL -
405
0001
ROUGH MECHANICAL -
12/09/04
APPROVED
- -_ 000
000
-M01
00
MECHANICAL - -"
_499
0001
MECHANICAL FINAL---
.:-° -`-4/18/05
APPROVED.--•'-
"• -`TM-
' 000
000
P01-
00
PLUMBING
."
200
0001
UNDERGROUND PLUMBING.
10/21/64
APPROVED'
- DC.
- 000
000
..P01
00
PLUMBING.
-.
210
0001
SEWER CONNECTION'
- 10/23/04
APPROVED
DC
" 000
000
P01
00
PLUMBING
-
230
0001
ROUGH PLUMBING
12/09/04
APPROVED
TM '.
000
000
P01
00
PLUMBING
245
0001
SHOWER PAN
"12/09/04
APPROVED ,.
TM_
000
000
P01
00
PLUMBING
235.
0001
GAS LINE / GAS TEST
3/01/05
APPROVED -
TM
" 000.000
P01.
00
PLUMBING.
.. -
- 299
0001
PLUMBING FINAL
4/18/05'APPROVED
TM -- ,.
Certificate of Insulation
Your home has been insulated with Johns Manville Fibealass insulation products, which are designed
for today's safety standards and tomorrow/s energy requirements.
v
Fiberglass is inorganic and therefore permanently noncombusfble, so it does not have to be treated
v
with fire -retardant chemicals that will likely lose their effectiveness over time. It has not been treated
with chemicals that can corrode wiring or metal. Fiberglass will not absorb moisture nor will it
r
settle over time as may other insulation materials_
D
This also certifies that insulation have been professionally installed in this home to provide the
follo'.ving thermal performance.
Lennar Momes,'lnc.
Job Name: La Quints Del Oro Tract: 30521 Plan# iZ & Casitas Phase: 6
Lot No: 34 Job Address:. SFR -44-795 Via Mlarabel, La Quinta, CA
Ceiling Area: R-38 blown and batt insu'ation Garage Ceiling: '"Non -Access: '
With Living Above . & Sloping Areas, �r
C
L
Exterior Walls R-13 bats insulation Overhangs. Access Attic:
IL
n
With Living Above
E
Between Floors: Interior Walls:
Subcontractor... 0 J Insulation, Inc.
72-227 Adelaid St: Thousand Palms, CA 92278 :.
IL
n
_ Signed:
Mike Dickerson, General Manager - Paim 'Springs Division
R -means resistance to heat flow. The higher the R -value, the greater the insulating power.
U
Ask your builder for the fact sheet on R -values. Keep this certificate with your other
U
valued papers. If you ever sell this home, this certificate should be passed on to the buyer.
L
IL
_. _
d
4� S
v .
CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7)
La Quinta Del Oro 4/14/2005
✓ �� (0
CF -4R �C!
Project Title Date
�-'� ��5 1 �. ► r��� Lennar
Project Address Builder Name'
Builder Contact Tel hone Plan Number
William Henson 760- -
HERS R Telephone Sample Group Number
Certifying Signature Date `Sample House Number
Fi :BCl TestingHERS Provider: CalCer
- r
Street Address: PO Box -50575 City/State/Zip: Phoenix, AZ 85076
Copies to: Builder, HERS Provider
HERS RATER COMPL ANCE STATEMENT
The house was: ❑ Tested Approved as part of sample testing, but was not tested
As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply
with the diagnostic tested compliance requirements as checked on this form.
❑ The installer has provided a copy of CF -6R (Installation Certificate.
❑ Distribution system is fully ducted (i.e.; does not use building cavities as plenums or platform returns in lieu of ducts)
❑ Where cloth backed, rubber adhesive duct tape is installed; mastic and drawbands are used in combination with cloth
backed, rubber adhesive duct tape to seal leaks at duct connections.
❑ MINIMU!VI REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT
Duct Diagnostic Leakage Testing Results,(Maximum 6%`Duct Leakage) -
Measured
Duct Pressurization Test Results (CFM @ 25 Pa) values
Test Leakage Flow in CFM "
If fan.flow is calculated as 400cfm/ton x number of tons enter calculated
value here
If fan flow is measured enter measured value here
Leakage Percentage (100 x Test Leakage/Fan Flow)
Check Box for Pass or Fail (Pass=6% or less) ❑ ❑
• Pass Fail
❑ THERMOSTATIC EXPANSION VALVE (TXV)
❑ Yes ❑ No Thermostatic Expansion Valve is installed and Access is
provided for inspection ❑ ❑
.Yes is'a pass Pass Fail
❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT
1 ❑ Yes - ❑ No ACCA Manual. D Design requirements have been met (rater has
verified that actual installation matches values in CF -IR and
design on plan.
2 ❑ Yes ❑ No TXVis installed or Fan flow has been verified. If no TXV,
verified fan flow matches design from CF -IR.
Measured Fan Flow
❑ ❑
F - Yes for both 1 and 2 is a Pass Pass Fail
L,ompuance forms August 2001 A-16