Loading...
04-4602 (SFD)Tiht V BUILDING & SAFETY DEPARTMENT P:•O_G oX 1,504 (760).777-7012 O I�yiti .78-195 CALLE TAMPICO " FAX (760) 777-7011 p LA QU IINTA, CALIFORNIA.92253 INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT CITY®1: LA X03136 A t�IMA96C ®I'� Application Number: 04-000,04602 Date 7/09/04 Property Address 44750 VIP; MIRABEL APN: 604 -032 -999 -31 -305212 - Application description- DWELLING:- SINGLE FAMILY DETACHED Property Zoning . . . . LOW DENSITY RESIDENTIAL Application Valuation 182517 Owner Contractor LENNAR HOMES OF .CALIFORNIA LENNAR HOMES OF CALIFORNIA INC' 78401 HIGHWAY 111, STE C .78401 HIGHWAY 111, SUITE C LA QUINTA, CA LA QUINTA CA 92253 LA QUINTA CA 92253 WCC: OLD REPUBLIC IN WC: MWC10877600 11/01/04 CSLB: 728102 09/30/04 CCC:' B ------------------=------- Structure Information -------------------------- Construction ----------------- ------Construction Type TYPE V - NON RATED Occupancy Type. DWELLG/LODGING/LONG <=10 Flood Zone NON -AO FLOOD ZONE Other struct info.. CODE EDITION 2001 CRC FIRE SPRINKLERS NO GARAGE SQ FTG 426:;00 PATIO SQ FTG 236.`00 NUMBER OF UNITS 1.00 FIRST FLOOR SQ FTG 2990.00 Permit . . . BUILDING PERMIT -Additional desc Permit Fee _930.00 Plan Check. Fee 604.50 Issue Date Valuation 182517 Qty Unit Charge Per Extension BASE FEE 639.50 83.00 3.5000 THOU BLDG 100,-001-500,000 290.50 Permit MECHANICAL Additional desc , Permit Fee 70.50 Plan Check Fee 17.63 Issue Date Valuation . . . . 0 Qty Unit Charge Per Extension P.O. Box 1504 • ��'� � VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 4INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: Applicant: Applicant's Mailing Address: or Date: $' /& -0 1. ress: Lic. No.: 3n`/f BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my Lice 6 is in full forcaand effect. 0d I�60� �icense Class fel nse No. ' /Date tv `d ontractor t VC OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is n i u or its compensation insurance carrier n �qJ�y nymy� re arrier t(/ LG C- —Policy Number _ I certify tha , in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. 5. / / .. - /[1-LL1 WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lenders Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I'agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. ig� nature (Applicant or Agent): Aqa r - Page 2 Application Number 04-00004602- Date 7/09/04 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 2.00 `9.0000 EA MECH B/C <=3HP/100K BTU 18.00 2.00 6.5000 EA MECH VENT FAN 13.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . . . ELEC-NEW RESIDENTIAL Additional desc.. Permit Fee 128.17 Plan Check Fee'. 32.04 Issue. Date Valuation 0 Qty Unit Charge Per Extension BASE FEE ' 4 15.00 2990.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 104.65 426.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 8.52 Permit . . . . PLUMBING Additional desc Permit,Fee 189,75 Plan Check Fee 47.44 Issue Date Valuation . . . 0 Qty Unit Charge Per Extension BASE FEE •15.00 20.00 6.0000 EA. PLB FIXTURE 120.00 1.00 15.0000 EA PLB BUILDING SEWER '15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000, EA PLB WATER-INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 7.00 :7500 EA PLB GAS PIPE >=5 5..25 1..00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Permit GRADING PERMIT Additional desc Permit Fee 15.00. Plan Check Fee .00 Issue Date Valuation . . 0 Qty Unit Charge- Per Extension BASE FEE 15.00 ----------------------------------------------------------------------------- Special Notes .and Comments SFD - LOT 31. PLAN 3Z. PERMIT DOES NOT l Page 3 Application Number 04=00004602 Date 7/09/04 ---------------------------------------------------------------------------- Special Notes and Comments .INCLUDE BLOCK WALLS, POOL, SPA OR �. DRIVEWAY APPROACH. Other Fees ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 60.45 DIF'FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE 00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF'PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 18..25 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary. Charged Paid Credited Due Permit Fee Total 13-33.42 .00, :00 1333.42 Plan Check Total 701.61 .•00•• .00 701.61 Other Fee Total 2483.70 .00 .00 2483.70. Grand Total 4518.73 .00 .00 4518.73 ID Certificate of Insulation Your home has been insu!ated with Johns P1lanvil'e Fibeglass insulation products, which are designed _ for today's safety standards and tomorrow's energy requirements. n Fiberglass is inorganic and therefore permanently, noncombustible, so it does not have to be treated v with fire -retardant chemicals that will likely lose their effectiveness over time. It has not been treated with chemicals that can corrode wring or metal. Fiberglass will not absorb moisture nor will it is settle over time as may other insulation materials. D This also certifies that insulation have been professionally installed in this home to provide the following thermal performance. Lennar Homes, Inc. Job Name: La Ouinta Del Oro Tract: 30521 _ Plana V Phase: S Lot No: 31 Job Address: SFR -44-750 Via Marabel; La ®uinta, CA Ceiling Area: R-38 blown and batt insulation Garage Ceiling: Non -Access: With Living Above & Sloping Areas C L Exterior Wall sR-13 batt insulation Overhangs: Access Attic: n With Living Above E " Between Floors: Interior Walls: Subcontractor...0 J Insulation, Inc. 72-227 Adelaid St, Thousand Palms, CA 92276 IL o Signed: M 1 U Mike Dickerson, Genera! Manager- Palm Springs Division R -means resistance to heat flow. The higher the R -value, the greater the insulating power. V Ask your builder for the fact sheet on R -values. Keep this certificate with your other v valued papers. If you ever sell this home, this certificate should be passed onto the buyer L IL L f `C CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page 1 of 7) CF4R La Quints Del Oro k 4/14/2005 Pr oject Title V DatLennar C, )1 U ' ` 1 C^ 1 Project Address Builder Name 3 Build C ptact 7 T�1 n Plan Number Jll�iam Henson 6 �,n t HERS Rat Telephone Sample Group Number C fying Signature Date Sample House, Number Firm:BCI Testing{ HERS Provider: CalCeitS Street Address: pO Box 50575 City/State/Zip: Phoenix, A7 85076 Copies to: Builder, HERS Provider HERS RATER COMPL AJVCESTATEMENT, , The house was: ❑ Tested Approved as ,part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form.. ❑ The installer has provided a copy of CF -6R (Installation Certificate. ' ❑ Distribution system is fully ducted (i.e., does not use building cavifies as plenums or platform returns in lieu of ducts) ❑ Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. t ❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) ' Measured Duct Pressurization Test Results (CFM @ 25 Pa) values ` Test Leakage Flow in CFM If fan flow is calculated as 400cfm/ton x number of tons enter calculated • , value here - If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) Check Box for Pass or Fail (Pass=6%°'or less). ❑ ❑ Pass' Fail ❑ THERMOSTATIC EXPANSION VALVE (TXV) ❑ Yes ❑ No Thermostatic Expansion Valve is±installed and Access is provided for inspection ❑ i Yes is a pass Pass, - ❑ Fail MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT 1 ❑ Yes ❑ No ACCA Manual D Design requirements have been met (rater has verified that actual installation matches values in CF -IR and design on plan. 2- ❑ Yes ❑ No TXV is installed or Fan flow has been verified. -Iino TXV, verified fan flow matches design from CF -1R. Measured Fan Flow_ *_ ❑ ❑ Yes for both 1 and 2 is a Pass Pass Fail A-16 Compliance Forms August 2001