13-1295 (RR)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 13-00001295
Property Address: 49499 EISENHOWER DR
APN: 658-190-011-30 -28545
Application description: RE -ROOF
Property Zoning: TOURIST COMMERCIAL
Application valuation: 19838
c&t!t 4 4 a"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Applicant: Architect or Engineer: D
C7fi j 1
clry
3
-----------------------------------------------------
FNgN E p�p�b�°q
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: C39 C46 license No.: 688062
Date: fo �10- Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty o perjury that I am exempt from the. Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 155001.:
1 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale ISec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contramor(s) licensed
pursuant to the Contractors' State License Law.).
( 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address: V �l
LQPERMIT
Owner:
KSL DESERT RESORT
C/O CNL HOSPITALITY PROP INC
450 S ORANGE AVE #12TH
ORLANDO, FL 32801
Contractor:
WINKLE COMPANY, R.D.
.O. BOX 476
IGUG;IiEl PA LMO, CA 92276
760)322-5144
ic. No.: 688062
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 10/10/13
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the fallowing declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
_ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 0000182-2013
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Code, I shall forthwith comply with those provisions.
Date: LO Ac/ Applicant: ( _
WARNING: FAILURF TO SE E WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS J$1 00,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter upon the above-mentioned property for inspection purposes.
Date/O U Signature (Applicant or Agent):
Application Number . . . . . 13-00001295
Permit . . . RE -ROOF
Additional desc .
Permit Fee . . . . 48.62 Plan Check
Fee
.00
Issue Date . . . . Valuation
. . .
. 0
Expiration Date . . 4/08/14
Qty Unit Charge Per
Extension
1.00 48.6200 LS MISC RE -ROOF, 1ST 2000
SF
48.62
-
-------------------------------------------------------
Special Notes and Comments
------
--------------
RE -ROOF DUNE CLUBHOUSE WITH 1/4" DENS
DECK, MECHANICALLY ATTACHED, INSTALL
60MIL TPO ROOFING SYSTEM (NOT REPLACING
CLAY TILE) [CRRC: 0628-0002] 2010
f DT,IFQr0iIA ENERGY CUDE.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . PLAN CHECK, RE -ROOF
97.24
Fee summary Charged Paid Credited
------------------------------
----------
Due
-----------------
Permit Fee Total 48.62 .00
.00
48.62
Plan Check Total .00 .00
.00
.00
Other Fee Total 97.24 .00
.00
97.24
Grand Total 145.86 .00
.00
145.86
LQPERMIT
Bin #
Qty. OF La Quii'�
Building a Safety Division
P.O. Box 1504,"78-495 Calle Tampico
La.Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
r_
ProjectAddress: 49-499 Eisenhower
owner's Name:. La Quinta Resort & Club
A. P. Number. 773021037
Address: 49-499 Eisenhower
Legal Description: Dune Clubhouse
city, sT, Zip: La Quinta, CA. 92253
Contractor. R. D. Winkle co.
Address: P.O. Box 476
��vs%sa r=
Telephone: �.s :r .-�..
P a." •:zap:? r:,.W >su�
Project Description: Re -Roof Equipment Well
City, ST, Zip: Thousand Palms, CA. 92276
Remove existing roofing, system ; 13 U//—
/Telephone:
Telephone:760-322-5144 «c>4? - ' �s
State Lic. #: 688062 City Lic. #,
Arch., Engr., Designer.
Install 1/a" Dens Deck, Mechanically Attached
Install 60mil TP_O Roofing System
� ; " 07 t J �� � �✓�
Address:
City., ST, Zip:
Telephone: `,,,>` Construction Type _ ROofing Occupancy: NO
ii`� ; `
State Lic. #:11i.. Project type (circle one): New Add'n Alter Repair Demo
Name of Contact Person: q� � Sq. Ft.: 600 # Stories: 2 # Units: 1
Telephone # of Contact Person: 7 O • Z72 09C3
Estimated value of Project: $ 19,838.00
APPLICANT: DO NOT WRITE BELOW THIS UNE
#
Submittal
Req'd
Reed
TRACMG
PERMIT FEES
Plan Sets
Plan Check submitted
Item Amount
Structural Cales.
Reviewed, ready for corrections
Plan Check Deposit
Truss Cafes.
Called Contact Person
Plan Check Balance
Title 24 Cales.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2`i Review, ready for correctioesrssue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S tiI,1
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'^' Review, ready for correctionsfissue
Developer Impact Fee
Planning Approval
Called Contact Person
A.LP.P.
Pub. Wks. Appr
Date of permit Issue
School Fees
Total Permit Fees
RIVERS°DE COUNTY GIS
Selected parcel(s):
654-160-057
`IMPORTAN-'
Maps and data are to be used for reference purposes only. Map feati-resareapproximate, and are not necess=_r lw accurate to surveying or
angineed ng stardards. The County of Riverside makes no wa.rra-ity or guarantee as to the content (the source s: ften third party), accuracy,
timeliness, or completeness of any of the data provided, and assLmes no legal responsibility for the inform aticn contained on this map. Any use of
this product with respect to accuracy and precision shall be the scle responsibility of the user.
2EPORT PRINTED ON ... Tue Oct 15 2013 10:20:55 GMT -0700 (Pac fic Daylight Time)
/ersion 131301
RIVERSIDE COUNTY GIS
Selected parcel(s):
658-160-057
'IMPORTANT*
Maps and data are to be used for reference purpose, - only. Map features are approximate. and are not necessarily accurate to surveying or
angin eering standards. The County of River3ide makes no warranty or guarantee as to the content (the source is often third party), accuracy,
timeliness, or com:)letenessof any of the data provided, and assumes no legal responsibility for the information contained on thisrnap. Any use of
this product with respect to accuracy and precision shall be the sole responsibility of the user.
2EPORT PRINTED ON ... Tue Oct 15 2013 09:46:32 GMT -0700 (Pacific Daylight Ti -ne)
/ersion 131001
Prescriptive Certificate of Compliance: Residential CF -IR -ALT
Residential Alterations age 3 of 5
Project Name: Climate Zone # # of Stories
Dune Clubhouse / 49-499 Eisenhower
ROOFING PRODUCTS (COOL ROOFS) §151(1)12
When the area of exterior roof surface to be replaced exceeds more titan 50% of the existing roof area, or more titan 1, 000 , whichever is
less, the new roofing area nuist meet the roofneg product "Cool Roof' requirements of §152(b)IHi,152(b)IHi4 or 152(b)IHik
Check applicable alternative or exception below if the roof alteration is exempt from the roofing product "Cool Roof ' requirements. Note: If any
one of the alternatives or exception below is checked, the Aged Solar Reflectance and Thermal Emittance requirements for roofing products in
§118(1) are not applicable. Do notfill table below.
❑ Cool Roofs Not Required in Climate Zones 1-12, 14, and 16 with a Low Sloped. Less or 2:12 pitch.
❑Cool Roofs Not Required in Climate Zones 1 through 9 and 16 with a Steep -Sloped Roofs (pitch greater than 2:12) and product unit weight less
than 51b/ft2.
Alternatives to §152(b)1Hi and §152(b)Hii, Steep -slope roof (pitch > 2:12)
❑ Insulation with a thermal resistance of at least 0.85 heft •°FBtu or at least a 3/4 inch air -space is added to the roof deck
over an attic, or
❑ Existing ducts in the attic are insulated and sealed according to §151(f)10; or
❑ In climate zones 10,12 and 13, with 1 ft2 of free ventilation area of attic ventilation for every 150 ft2 of attic floor area, and
where at least 30 percent of the free ventilation area is within 2 feet vertical distance of the roof ridge; or
❑ Building has at least R-30 ceiling insulation; or
❑ Building has radiant barrier in the attic meeting the requirements of § 151(f)2; or
❑ Building has no ducts in the attic; or
❑ In climate zones 10, 11,13 and 14, R-3 or greater roof deck insulation above vented attic.
Exception to §152(b)1Hiii, Low -slope roof (pitch <2:12)
❑ Building has no ducts in the attic.
Other Exceptions
❑ Roofing area covered by building integrated; photovoltaic panels and solar thermal panels are exempt from the below Cool Roof criteria.
❑ Roof constructions that have thermal mass over the roof membrane with at least 251b/ft2 is exempt from the below Cool Roof criteria.
Note: If no CRRC-1 label is available, this compliance method cannot be used, use the Performance Approach to show compliance, otherwise,
Check the applicable box below if Ex em t from the Roof-inProducts "Cool RoofRequirement:
Roof Slope
Product Weight
Product
Aged Solar
Thermal
CRRC Product ID Number
< 2:12 > 2:12
< 5lb/ft2 > 51b/ft2
TYPe2
Reflectance 3,4
Emittance
SRI
0628-0002
[a
❑
❑
❑
TPO
❑4
0.70
0.90
99
❑
❑
❑
❑
❑4
❑
❑
❑
❑
❑4
❑
❑
❑
❑
❑4
❑
❑
❑
❑
❑4
1. The CRRC Product ID Number can be obtained from the Cool RoofRating Council's Rated Product Directory at www.coolroofs.org/oroducts/search.php
2. Indicate the type ofproduct is being used for the roof top, i. e. single -ply roof, asphalt roof, metal roof, etc.
3. If the Aged Reflectance is not available in the Cool RoofRating Council's Rated Product Directory then use the Initial Reflectance value from the some
directory and use the equation (0.2+0.7(pi„itiot— 0.2) to obtain a calculated aged value. Where pis the Initial Solar Reflectance.
4. Check box if the Aged Reflectance is a calculated value using the equation above.
5. Calculate the SRI value by using the SRI- Worksheet at ht&2.-Ilwww.enerey.ca.jzovltitle24/and enter the resulting value in the SRI Column above and attach acopy of
the SRI- Worksheet to the CF -IR.
o apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage
ecommended by the coatings manufacturer and meet minimum performance requirements listed in §118(i)4. Select the applicable coating:
❑ Aluminum -Pigmented Asphalt Roof Coating
113 Cement -Based Roof Coating
113 Other
Registration Number: Registration Date/Time: HERS Provider:
2008 Residential Compliance Forms August 2009
Find rated products - Cool Roof Rating Council
1 SEARCH RESULTS
Selected filters
Manufacturer: Carlisle Construction Materials Incorporated
10/9/13 12:27 PM
PRINT EXPORT ALL PRODUCTS
CRRC PROD. ID MANUFACTURER: BRAND PRODUCT TYPE COLOR SOLAR REFLECTANCE THERMAL EMITTANCE SRI MORE
MODEL INFO
initial 3 year initial 3 year initial 3 year
0628-0002 Carlisle Construction Materials Membrane: Single Bright White 0.79 0.70 0.90 0.86 99 85
Incorporated: Sure -Weld Ply Thermoplastic
TPO White and Thermoset
Roofing
COOL ROOF RATING COUNCIL
1610 Harrison Street Tel (866) 465-2523 or Fax (5 10) 482-4421
Oakland, CA 94612 (510) 485-7175 Email: info@coolroofs.org
http://coolroofs.org/products/results Page 1 of 1
IMES Evaluation Report ESR -1463
V ` ICC-ES/UL
Dual Report
Reissued August 1, 2012
This report is subject to renewal October 1, 2014.
Click on the logo to access UL CenSfication
www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council®
DIVISION: 07 00 00—THERMAL AND MOISTURE
PROTECTION
Section: 07 53 23—Ethylene-Propylene-Diene-Monomer
Roofing
Section: 07 54 19—Polyvinyl-Chloride Roofing
Section: 07 54 23—Thermoplastic-Polyolefin Roofing
REPORT HOLDER:
CARLISLE SYNTEC INCORPORATED
PO BOX 7000
CARLISLE, PENNSYLVANIA 17013
(717) 245-7000
www.carlisle-syntec.com
EVALUATION SUBJECT:
CARLISLE EPDM, PVC AND TPO SINGLE -PLY ROOFING
MEMBRANES
ADDITIONAL LISTEES:
VERSICO INCORPORATED
POST OFFICE BOX 1289
CARLISLE, PA 17013
MULE -HIDE PRODUCTS COMPANY, INC.
1195 PRINCE HALL DRIVE
BELOIT, WISCONSIN 53511
WEATHERBOND
P.O. BOX 251
PLAINFIELD, PENNSYLVANIA 17081
KELLY COMPANY/2001 INC.
325 THOMASTON AVENUE
WATERBURY, CONNECTICUT 06702
1.0 EVALUATION SCOPE
Compliance with the following codes:
■ 2006 International Building Code (IBC)
■ 2006 International Residential Code® (IRC)
■ Other Codes (see Section 8.0)
Properties evaluated:
■ Weather resistance
■ Roof covering fire classification
■ Wind uplift resistance
■ Impact resistance
2.0 USES
Carlisle ethylene propylene diene monomer (EPDM),
polyvinyl chloride (PVC) and thermoplastic polyolefin
(TPO) single -ply roofing membranes are used as roof
coverings in adhered and mechanically fastened
membrane roofing systems.
3.0 DESCRIPTION
3.1 General:
The EPDM, PVC and TPO Membrane Roofing Systems
described in this report consist of single -ply roofing
membranes, insulation where used, barrier board or slip
sheet where used, flashing, mechanical fasteners and
adhesives that are installed on a combustible or
noncombustible deck See Table 1 for Carlisle product
trade names and corresponding product names for
Mule -Hide Products Company, Inc., WeatherBond, Versico
Incorporated and Kelly Company/2001 Inc., the additional
listees.
3.2 EPDM Membranes:
3.2.1 Sure -Seal: Sure -Seal is a black, nonreinforced
EPDM membrane available in 45-, 60- and 90 -mil
(1.14, 1.52, and 2.29 mm) thicknesses.
3.2.2 Sure -Seal FR: Sure -Seal FR is a black,
nonreinforced EPDM membrane with fire retardants,
available in 45-, 60- and 90 -mil (1.14, 1.52, and 2.29 mm)
thicknesses.
3.2.3 Sure -White: Sure -White is a white, nonreinforced
EPDM membrane available in a 60- and 90 -mil (1.52 and
2.29 mm) thickness.
3.2.4 Sure -Tough: Sure -Tough is a black, reinforced
membrane consisting of a polyester reinforcement
encapsulated between two EPDM membrane plies. It is
available in 45- to 75 -mil (1.14 to 1.90 mm) thicknesses.
3.2.5 Sure -Tough FR: Sure -Tough FR is a black,
reinforced membrane consisting of a polyester
reinforcement encapsulated between two EPDM
membrane plies with fire retardants. It is available in 45 to
60 -mil (1.14 to 1.52 mm) thickness.
3.2.6 Sure -Seal FleeceBACK: Sure -Seal FleeceBACK is
a 45-, 60- or 90 -mil (1.14, 1.52 or 2.29 mm) non -reinforced
EPDM bonded to a 5.5 -ounce -per -square -yard (0.18
kg/M2) polyester fleece.
3.2.7 Sure -White FleeceBACK: Sure -White FleeceBACK
is a 60- or 90 -mil (1.52 or 2.29 mm) nonreinforced white
EPDM bonded to a 5.5 -ounce -per- square -yard (0.18
kg/mZ) polyester fleece.
ICC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed nor are they to be construed
as an endorsement of the subject of the rep on or a recommendation far its use. There is no warranty by ICC Evaluation Service, LLC, express or implied as�. ►,����y��
ESR -1463 1 Most Widely Accepted and Trusted Page 2 of 10
3.2.8 Sure -Seal AFX: Sure -Seal AFX is a 45-, 60- or
90 -mil (1.14, 1.52 or 2.29 mm) non -reinforced EPDM
bonded to a 7.5 -ounce -per -square -yard (0.25 kg /M2)
polyester fleece.
3.2.9 Sure -Seal AFX PLUS: Sure -Seal AFX PLUS is a
60 -mil (1.52 mm) non -reinforced EPDM bonded to a
7.5 -ounce -per -square -yard (0.25 kg /M2) polyester fleece.
3.3 PVC Membranes:
3.3.1 Sure -Flex and Sure -Flex Elvaloy: Sure -Flex and
Sure -Flex Elvaloy are 50-, 60-, or 80 -mil (1.27, 1.52, or
2.03 mm) membranes consisting of a polyester
reinforcement encapsulated between two plies of PVC.
The membrane is available in white, gray or custom colors.
3.3.2 Sure -Flex FRS and Sure -Flex Elvaloy FRS: Sure -
Flex FRS and Sure -Flex Elvaloy FRS are 50-, 60-, or
80 -mil (1.27, 1.52, or 2.03 mm) membranes consisting of a
fiberglass reinforcement encapsulated between two plies
of PVC. The membrane is available in white, gray or
custom colors.
3.3.3 Sure -Flex FRS FleeceBACK and Sure -Flex
Elvaloy FRS FleeceBACK: Sure -Flex FRS FleeceBACK
and Sure -Flex Elvaloy FRS FleeceBACK are the Sure -Flex
FRS membrane and the Sure -Flex Elvaloy FRS
membrane, described in Section 3.3.2 with a laminated
5.5 -ounce -per -square -yard (0.18 kg/m) polyester fleece
backing.
3.4 TPO Membranes:
3.4.1 Sure -Weld: Sure -Weld is a 45- or 60 -mil (1.14 or
1.52 mm) membrane consisting of a polyester
reinforcement encapsulated between two plies of TPO.
The membrane is available in white, gray, tan or custom
colors.
3.4.2 Sure -Weld HS: Sure -Weld HS is the Sure -Weld
membrane formulated with an additional flame retardant
for fire resistance at higher slopes. It is manufactured in
45- and 60 -mil (1.14 or 1.52 mm) thicknesses, and is
available in white, gray, tan or custom colors.
3.4.3 SAT-TPO: SAT-TPO is a self -adhered version of
Sure -Weld HS membrane with adhesive.
3.4.4 Sure -Weld EXTRA: Sure -Weld EXTRA is the same
formulation as the Sure -Weld membrane but comes in
72- and 80 -mil (1.83 and 2.03 mm) thicknesses.
3.4.5 Sure -Weld HS EXTRA: Sure -Weld HS EXTRA is
the same formulation as the Sure -Weld HS membrane but
comes in 72- and 80 -mil (1.83 and 2.03 mm) thicknesses.
3.4.6 Sure -Weld FleeceBACK: Sure -Weld FleeceBACK
is the Sure -Weld HS membrane, 45 or 60 mils (1.14 or
1.52 mm) thick with a laminated 5.5 -ounce -per -square -
yard (0.18 kg/m2) polyester fleece backing.
3.4.7 Sure -Weld AFX: Sure -Weld AFX is the 45 -mil
(1.14 mm) Sure -Weld HS membrane with a laminated
10 -ounce -per -square -yard (0.34 kg /M2)
polyester fleece
backing.
3.4.8 Sure -Weld AFX PLUS: Sure -Weld AFX PLUS is
the 60 -mil (1.52 mm) Sure -Weld HS membrane with a
laminated 10 -ounce -per -square -yard (0.34 kg/m2)
polyester fleece backing.
3.4.9 Spectro-Weld: Spectro-Weld is the Sure -Weld
membrane, described in Section 3.4.1, and Sure -Weld
EXTRA membrane, described in Section 3.4.4, formulated
3.4.10 Spectro-Weld FleeceBACK: Spectro-Weld
FleeceBACK is the Spectro-Weld membrane with a
laminated 5.5 -ounce -per -square -yard (0.18 kg /M2)
polyester fleece backing.
3.5 Insulation:
See Tables 2 through 4 for insulations for use with specific
roofing systems. Foam plastic insulation, where used, must
have a flame -spread index of not more than 75 when
tested at the maximum thickness intended for use in
accordance with ASTM E 84.
3.6 Barrier Board:
Barrier board, where used, must be either minimum
1/4 -inch -thick (6.4 mm� G -P Gypsum Corporation
"DensDeck," minimum /4 -inch -thick (6.4 mm) Owens
Corning "Strataguard", minimum 1/4 -inch -thick (6.4 mm)
USG "Securock," or minimum 1/2 -inch -thick (12.7 mm)
gypsum board. Barrier board must be UL- listed for roofing
applications or UL -classified gypsum board.
3.7 Slip Sheet:
The slip sheet, where used, must include Carlisle "FR
Base Sheet 1S or 2S," Elk "VersaShield Underlayment,"
Elk "VersaShield FB -1S or FB -2S, or Atlas FR 10 or
FR 50."
3.8 Flashing:
Flashing must be provided in accordance with IBC Section
1503.2 or IRC Section 8903.2, as applicable. Where
flashing is of metal, the metal must be corrosion -resistant,
minimum No. 26 gage [0.019 inch (0.483 mm)] galvanized
steel.
3.9 Fasteners:
Fasteners, used to mechanically attach insulation and
membranes to the roof deck, must be corrosion -resistant,
and must be Carlisle fasteners, plates or fastening bars,
unless otherwise noted in this report. Refer to Table 4 for
spacing of fasteners.
3.9.1 Sure -Seal HP Fastener: This is an epoxy -coated
steel screw used in combination with Carlisle's fastening
plates or bars to mechanically attach roofing insulation and
membranes to steel or wood substrate. Fastener length
must be selected to penetrate through the steel deck a
minimum of 3/4 inch (19.1 mm), and into the wood deck a
minimum of 1 inch (25.4 mm).
3.9.2 Sure -Seal HP Purlin Fastener: This is an epoxy -
coated steel screw used in combination with Carlisle's
fastening plates or bars to mechanically attach roofing
insulation and membranes to structural steel members.
Fastener length must be selected to penetrate through the
steel member a minimum of 3/4 inch (19.1 mm.)
3.9.3 Sure -Seal HD 14-10 Fastener: This is a heavy-
duty, epoxy -coated steel screw used in combination with
Carlisle's fastening plates or bars to mechanically attach
roofing insulation and membranes to concrete roof deck.
Fastener length must be selected to penetrate into the
concrete deck a minimum of 1 inch (25.4 mm).
3.9.4 Sure -Seal HP Polymer Seam Plate: This is a
2 -inch -diameter (50 mm) polymer plate designed to be
used with Sure -Seal HP and Sure -Seal HD 14-10
fasteners to mechanically attach roofing membranes to the
roof deck.
3.9.5 Sure-Tite Fastener and ST Fastening Bar: This is
a heavy-duty, epoxy -coated steel screw and bar used to
secure reinforced EPDM membranes to steel or wood
deck. The bar is 1-inch-wide-by-0.040-inch-thick-by-10-
ESR -1463 1 Most Widely Accepted and Trusted Page 3 of 10
3.9.6,. HP -X Fastener: This is an epoxy -coated carbon
steel screw used in combination with the Piranha
Fastening Plate to mechanically attach TPO membranes to
steel or wood substrate. Fastener length must be selected
to penetrate through the steel deck a minimum of 3/4 inch
(19.1 mm), and into the wood deck a minimum of 1 inch
(25.4 mm).
3.9.7 Piranha Fastening Plate: This is a 23/8 -inch -
diameter galvalume-coated steel plate designed to be used
with HP -X fasteners to mechanically attach PVC and TPO
membranes to the roof deck.
3.9.8 HP-XTRA Fastener: This is an epoxy -coated
carbon steel screw used in combination with the Piranha
XTRA Fastening Plate to mechanically attach PVC and
TPO membranes to steel or wood substrate. Fastener
length must be selected to penetrate through the steel
deck a minimum of 3/4 inch (19.1 mm) and into the wood
deck a minimum of 1 inch (25.4 mm).
3.9.9 Piranha XTRA Fastening Plate: This is a
23/8 -inch -diameter galvalume-coated steel plate designed
to be used with HP-XTRA fasteners to mechanically attach
PVC and TPO membranes to the roof deck.
3.9.10 OMG Inc. RhinoBond Plate: The RhinoBond Plate
is a 3 -inch -diameter (76.2 mm), 0.028 -inch -thick (0.7 mm)
galvalume-coated steel plate, coated with a proprietary
adhesive and used with the HP -X fastener to mechanically
attach PVC and TPO membranes to the roof deck. The
adhesive bonds the plate to the underside of the
membrane.
3.10 Adhesives:
3.10.1 Sure -Seal 90-8-30A: Sure -Seal 90-8-30A is a high-
strength, solvent -based contact adhesive used to adhere
EPDM membranes to the insulation or substrate. It has a
coverage rate of approximately 60 square feet per gallon
(1.5 m /L). The adhesive is supplied in 5 -gallon (18.9 L)
containers and has a shelf life of one year.
3.10.2 Sure -Seal Aqua Base 120: Sure -Seal Aqua Base
120 is a high-strength, water-based contact adhesive used
to adhere EPDM and TPO membranes to the insulation or
substrate. It has a coverage rate of approximately 120
square feet per gallon (3 M2 /L). The adhesive is supplied in
5 -gallon (18.9 L) containers and has a shelf life of
one year.
3.10.3 Sure -Flex PVC Bonding Adhesives: Sure -Flex
PVC and Sure -Flex Low VOC PVC Bonding Adhesives are
high-strength, solvent -based contact adhesives used to
adhere PVC membranes to an insulation or substrate.
They have a coverage rate of approximately 60 square feet
per gallon (1.5 m /L). The adhesives are supplied in
5 -gallon (18.9 L) containers with a shelf life of one year.
3.10.4 Sure -Weld Bonding Adhesive: Sure -Weld
Bonding Adhesive is a high-strength, solvent -based
contact adhesive used to adhere TPO membranes to an
insulation or substrate. It has a coverage rate of
approximately 60 square feet per gallon (1.5 M2 /Q. The
adhesive is supplied in 5 -gallon (18.9 L) containers with a
shelf life of one year.
3.10.5 Low VOC Bonding Adhesive: Low VOC Bonding
Adhesive is a high-strength, solvent -based contact
adhesive used to adhere membranes to an insulation or
substrate. It has a coverage rate of approximately 60
square feet per gallon (1.5 m / Q. The adhesive is supplied
in 5 -gallon (18.9 L) containers with a shelf life of one year.
3.10.6 FAST Adhesives: FAST 100, FAST 100LV, FAST
Adhesive Dual Cartridge, FAST Adhesive Box Sets,
FleeceBACK membranes and insulations to various
substrates. The adhesives have a coverage rate of
approximately 100 square feet per gallon (2.5 M2 /Q. The
adhesives are supplied in 15 -gallon (56.7 L) and 50 -gallon
(189 L) drums, cartridge tubes or cylinders, and have a
shelf life of one year.
3.11 Impact Resistance:
The EPDM, PVC, and TPO roofing membranes described
in this report meet requirements for impact resistance in
IBC Section 1504.7, based on testing in accordance with
FM 4470.
4.0 INSTALLATION
4.1 General:
Installation of the EPDM, PVC, and TPO roofing
membranes described in this report must comply with the
applicable code, the manufacturer's published installation
instructions and this report. The manufacturer's published
installation instructions must be available at all times on
the jobsite during installation.
The substrate to which the membrane is to be applied
must be clean, dry, and free of frost, loose fasteners, and
other protrusions or contaminates that will interfere with the
adhesion or attachment of the membrane or that will
puncture the membrane. All materials must be protected
against contact with incompatible materials. Where
gypsum board is used as barrier board in the roofing
assembly, weather protection must be provided to prevent
damage to the gypsum board prior to application of the
roofing membrane.
The slope of the roof on which the single -ply membranes
are installed must not be more than the maximum slope
indicated for the particular assembly as listed in Tables
2 and 3.
Penetrations and terminations of the roof covering must
be flashed and made weather tight in accordance with the
requirements of the membrane manufacturer and the
applicable code.
4.2 Fire Classification:
4.2.1 New Construction: The adhered and mechanically
fastened EPDM, PVC, and TPO single -ply membrane
roofing systems, when installed in accordance with this
report, are Class A, B or C roof covering systems in
accordance with ASTM E 108 and UL 790, as noted in
Tables 2 and 3.
4.2.2 Reroofing: The existing deck must be inspected to
verify that the structure to be reroofed is structurally sound
and adequate to support and secure the roofing
membrane. Prior to installation of new roof coverings,
inspection by and written approval from the code official
having jurisdiction must be required.
Class A, B or C roof covering systems may be installed
over existing classified roof covering systems under the
following conditions without additional roof classification
tests, provided the resulting classification is the lower of
the new or existing roofing classification:
■ New uninsulated systems installed only over existing
uninsulated assemblies.
■ New insulated systems installed over existing
uninsulated systems only.
4.3 Wind Resistance:
4.3.1 New Construction: The allowable wind uplift
pressures for the EPDM, PVC, and TPO roofing
ESR -1463 ( Most Widely Accepted and Trusted Page 4 of 10
Metal edge securement for roofing systems must be
designed in accordance with ANSI/SPRI ES -1, complying
with IBC Section 1504.5. The edge securement for
mechanically attached membranes was tested in
accordance with ANSI/SPRI ES -1 Test RE -1, using
Carlisle SecurEdge 300 [0.050 -inch (1.27 mm) 3003
aluminum] and Carlisle SecurEdge 3000 [0.040 -inch
(1.02 mm) 3003 aluminum] fascia systems. The maximum
allowable load for Carlisle SecurEdge 300 is 234 plf
(348 kg/m). The maximum allowable load for Carlisle
SecurEdge 3000 is 200 plf (298 kg/m).
4.3.2 Reroofing: Mechanically anchored systems may
be accepted based on the adequacy of anchors
penetrating through existing roof coverings into structural
substrates. Since the composition and/or condition of any
particular existing underlying material may vary widely,
reroofing with adhered systems is outside the scope of this
report.
5.0 CONDITIONS OF USE
The single -ply EPDM, PVC, and TPO roofing membranes
described in this report comply with, or are suitable
alternatives to what is specified in, those codes listed in
Section 1.0 of this report, subject to the following
conditions:
5.1 Installation must comply with the applicable code, the
manufacturer's published installation instructions and
this report. The instructions within this report must
govern if there are any conflicts between the
manufacturer's installation instructions and this report.
5.2 The adhered and mechanically fastened single -ply
membrane roofing systems must be installed by
professional roofing contractors who are trained and
approved by the manufacturer.
5.3 Foam plastic insulation must be separated from the
interior of the building by an approved thermal barrier
in accordance with IBC Section 2603.4.1.5 or IRC
Section R314.4, as applicable.
5.4 Foam plastic insulation, where used, must bear the
label of an approved agency indicating that the foam
plastic has a flame -spread index of not more than 75
when tested at the maximum thickness intended for
use in accordance with ASTM E 84, subject to the
approval of the code official.
5.5 Design wind uplift pressure on any roof area,
including edge and corner zones, must not exceed
the allowable wind uplift pressure for the system
installed in that particular area. Refer to allowable
wind uplift pressures for systems as listed in Table 4.
5.6 The allowable wind uplift pressures listed in Table 4
are for the roof covering system only. The deck and
framing to which the system is attached must be
designed for the applicable components and cladding
wind loads in accordance with the applicable code.
5.7 When application is over existing roofs,
documentation of the wind -uplift resistance of the
composite roof construction must be submitted to the
code official for approval at the time of permit
application.
5.8 The roofing membranes are manufactured at Carlisle,
Pennsylvania; Greenville, Illinois; Tooele, Utah; and
Senatobia, Mississippi, under a quality control
program with inspections by UL LLC (AA -668).
5.9 For buildings under the IBC, above-de6k thermal
insulation board must comply with the applicable
standards listed in Table 1508.2 of the IBC.
6.0 EVIDENCE SUBMITTED
Data in accordance with ICC -ES Acceptance Criteria for
Membrane Roof Covering Systems (AC75), dated April
2007, (corrected December 2008).
7.0 IDENTIFICATION
Each roll of the roofing membrane must bear a label noting
the product name, the manufacturer's name (Carlisle
SynTec Incorporated) or the name of the additional listee,
the manufacturer's address or plant code, the ICC -ES
evaluation report number (ESR -1463), and the name or
label of the inspection agency (UL LLC).
8.0 OTHER CODES
In addition to the codes referenced in Section 1.0, the
products in this report were evaluated for compliance with
the requirements of the following codes:
■ BOCe National Building Code/1999 (BNBC)
■ 1999 Standard Building Code® (SBC)
■ 1997 Uniform Building Code TM' (UBC)
For compliance under the above codes, see Sections 2
through 7 of this report, except revise the following
sections to read as follows:
3.8 Flashing:
Flashing must be provided in accordance with SBC
Section 1503.2, BNBC Section 1508.1 and UBC Section
1509, as applicable. Where flashing is of metal, the metal
must be corrosion -resistant, minimum No. 26 gage [0.019
inch (0.483 mm)] galvanized steel.
3.11 Impact Resistance:
The EPDM, PVC, and TPO roofing membranes described
in this report meet requirements for impact resistance in
BNBC Section 1505.4.2, and SBC Section 1504.6, based
on testing in accordance with FM 4470.
4.3.1 New Construction: The allowable wind uplift
pressures for the EPDM, PVC, and TPO roofing
membranes as parts of roof assemblies are noted in
Tables 4 and 5.
5.0 CONDITIONS OF USE
The single -ply EPDM, PVC, and TPO roofing membranes
described in this report comply with, or are suitable
alternatives to what is specified in, those codes listed in
Section 8.0 of this report, subject to the following
conditions:
See Sections 5.1 through 5.8, except revise Section 5.3 to
read as follows:
5.3 Foam plastic insulation must be separated from the
interior of the building by an approved thermal barrier
in accordance with BNBC Section 2603.4.1.5, SBC
Section 2603.5.1.5, and UBC Sections 2602.4 and
2602.5.3, as applicable.
• ESR -1463 1 Most Widely Accepted and Trusted Page 7 of 10
M TABLE 2—FIRE CLASSIFICATION ASSEMBLIES—ADHERED ROOFING SYSTEMS25
SYSTEM
ROOF
DECK
BARRIER BOARD
INSULATION'
MEMBRANEIMAX. ROOF SLOPE
NO.
CLASS
OR SUP SHEET
Any of the following insulations,
Sure -Weld, Spectro-Weld -'/4:12
1 -inch min. to 6 -inch max.
Sure -Seal, Sure -Tough, Sure -White, Sure -
thickness: Carlisle "SecurShield
Seal FleeceBACK, Sure -Weld HS, SAT-TPO,
1
A
Noncombustible
Polyiso", "Polyiso HP -H", Hunter
Sure -Weld FleeceBACK 11 Spectro-Weld
"H
FleeceBACK - /2:12
Panels -Shield" or
"H -Shield -CG"
Sure -White FleeceBACK, Sure -Flex, Sure -
Flex FRS - 3/4:12
1/2 -inch -thick fiberboard 4,'/2
Sure -White FleeceBACK -3/4:12
inch -thick fiberboard or barrier
board (see Section 3.6) over 5
Sure -Seal, Sure -Tough 1:12
2
A
Noncombustible
—
inch max Insulfoam EPS, 1/,
Sure -White, Sure -Seal FleeceBACK, Sure -
inch thick fiberboard or barrier
Weld, Spectro-Weld, Sure -Weld HS, SAT -
board (see Section 3.6) over
TPO, Sure -Weld FleeceBACK, Spectro-Weld
System No. 1 insulations
FleeceBACK, Sure -Flex, Sure Flex FRS
11/2:12
Sure -White FleeceBACK-3/4:12
Noncombustible or
Sure -White, Sure -Seal FleeceBACK - 1'/2:12
Combustible - min.
Sure -Tough, Sure -Weld, Spectro-Weld, Sure -
3
A
15/,,inch-thick
Barrer board
—
Weld FleeceBACK, Spectro-Weld
plywood or min.
(see Section 3.6)
FleeceBACK - 3:12
7/16 -inch -thick OSB.
Sure -Weld HS, SAT-TPO - 4:12
Sure -Seal FR, Sure -Flex, Sure -Flex FRS —
unlimited slope
Any of the following insulations,
Sure-Weld_Spectro-Weld -'/4:12
Combustible - min.
Barrier board1-inch
min.
Sure -Seal, Sure -Tough, Sure -White, Sure -
15/3z -inch -thick
(see Section 3.6) or
to 6 -inch max. thickness:
Seal FleeceBACK, Sure -Weld HS, SAT-TPO,
4
A
plywood or min.
Slip sheet: 2 layers
Carlisle "SecurShield Polyiso",
Sure -Weld FleeceBACK, Spectro-Weld
7/16 -inch -thick OSB.
(see Section 3.7)
Polyiso HP -H",
"H
FleeceBACK /2:12
Hunter Panels -Shield" or
Sure -White FleeceBACK, Sure -Flex, Sure -
"H -Shield -CG"
Flex FRS -3/4:12
Combustible - min.
15/3z
Any of the following insulations,
Sure -Weld HS,
Sure Weld, Sure
5
C
-inch -thick
plywood or min.
_
2 -inch min. to 6 -inch max.
thickness: Carlisle "Polyiso HP-
-F ex, Sufd,
SAT TPO, Sure Flex, Sure -Flex FRS —
'/18 -inch -thick OSB.
H" or Hunter Panels "H -Shield'
unlimited slope
Single layer of minimum 3.0" or
double layer of minimum 1.5"
6
A
Combustible
—
Carlisle "SecurShield Polyiso" or
EPDM, PVC, and TPO Membranes -'/2:12
Hunter Panels
"H -Shield -CG"
Single layer of minimum 1.9"
7
B
Combustible
_
Carlisle "SecurShield Polyiso" or
EPDM, PVC, and TPO Membranes -'/2:12
Hunter Panels
"H -Shield -CG"
For SI: 1 inch = 25.4 mm.
'All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in
accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less.
2See Section 3.10 for adhesive application rate.
3 U Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanu rate insulations (max slope1:12) or below
min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks.
°Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When
these two boards are used directly below the Sure -Weld membrane, the slope is limited to max. 1/2:12.
5When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and
IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable
ESR -1463 1 Most Widely Accepted and Trusted Page`8 of 10
TABLE 3—FIRE CLASSIFICATION ASSEMBLIES—MECHANICALLY FASTENED ROOFING SYSTEMS°
SYSTEM
ROOF
DECK
BARRIER BOARD
INSULATION'
MEMBRANE/MAX. ROOF
NO.
CLASS
OR SLIP SHEET
SLOPE
Any of the following insulations, 1 -inch min. to
Sure -Tough, Sure -Weld,
1
A
Noncombustible
—
6 -inch max. thickness: Carlisle "SecurShield
"H-
Spectro-Weld, Sure -Flex, Sure -
Flex FRS -/2:12
Polyiso" or "Polyiso HP -H", Hunter Panels
Sure -Weld HS - 1'/2:12
Shield" or "H -Shield -CG"
Sure -Tough FR - 2:12
1/2 -inch -thick fiberboard 3,'/2 -inch -thick
Sure -Tough, Sure -Weld HS,
fiberboard" or barrier board (see Section 3.6)
Sure -Flex, Sure -Flex FRS - 1:12
2
A
Noncombustible
—
over 5 -inch max Insulfoam EPS2, '/2 -inch -thick
Sure -Weld, Spectro-Weld -
fiberboard or barrier board (see Section 3.6)
02:12
over System No. 1 insulations
Sure -Tough FR - 31/2:12
Sure -Weld, Spectro-Weld, Sure -
3
A
Noncombustible
—
To 5 -inch max: Insulfoam SP
Weld HS, Sure -Flex, Sure -Flex
FRS -'/2:12
Noncombustible or
Sure -Tough, Sure -Weld,
4
A
Combustible - min.
'5/32 -inch -thick
board
Be
—
Spectro-Weld - 3:12
Sure -Tough FR - 31/2:12
plywood or min.
Section 3rner
(see .6)
Sure -Weld HS, Sure -Flex, Sure -
'/16 -inch -thick OSB.
Flex FRS - unlimited
Combustible min.
Barrier board
Any of the following insulations, 1 -inch min.
Sure -Tough, Sure -Weld,
is
/32 -inch -thick
(see Section 3.6)
to 6 -inch max. thickness: Carlisle
Spectro-Weld, Sure -Flex, Sure -
5
A
plywood or min.
or Slip sheet: 2
"SecurShield Polyiso" or "Polyiso HP -H",
Flex FRS - /2:12
/,e -inch -thick OSB.
layers, see Section
(3.7)
Hunter Panels
Sure -Weld HS, 1'/2:12
3.7)
"H -Shield" or "H -Shield -CG"
Sure -Tough FR - 2:12
Combustible - min.
Sure -Tough - 1:12
6
A
'5/32 -inch -thick
Slip sheet, 2 layers
—
Sure -Tough FR, Sure Weld,
Spectro-Weld, Sure -Weld HS,
plywood or min.
7/16 OSB.
(see Section 3.7)
Sure -Flex, Sure -Flex FRS -
-inch -thick
1 /2:12
Combustible - min.
Sure -Tough, Sure -Tough FR,
15/32 -inch -thick
Slip sheet, 1 layer
Sure -Weld, Spectro-Weld,
7
B
plywood or min.
(see Section 3.7)
—
Sure -Weld HS, Sure -Flex, Sure -
7/16 -inch -thick OSB.
Flex FRS - 11/2:12
Combustible - min.
Any of the following insulations, 2 -inch min.
15/32
to 6 -inch max. thickness: Carlisle
Sure -Weld, Spectro-Weld,
6
C
-inch -thick
—
"SecurShield Polyiso" or "Polyiso
Sure-
Sure -Weld HS, Sure -Flex, Sure -
plywood or min.
7/jr,-inch-thick
HP -H", Hunter Panels "H -Shield" or H -Shield
Flex FRS - unlimited
OSB.
CG"
Single layer of minimum 3 -inch or double
layer of minimum 1.5 -inch Carlisle
EPDM, PVC, and TPO
9
A
Combustible
—
"SecurShield Polyiso" or
Membranes -'/2:12
Hunter Panels "H -Shield -CG"
Single layer of minimum 1.9 -inch Carlisle
"SecurShield Polyiso" or Hunter Panels "H-
EPDM, PVC, and TPO
10
B
Combustible
—
Shield -CG" or single layer of an inverted G3
Membranes -'/2:12
cap sheet.
For SI: 1 inch = 25.4 mm.
' All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in
accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less.
2 U Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanu rate insulations (max slope1:12) or below
min. 1/2 -inch -thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks.
3Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When
these two boards are used directly below the Sure -Weld membrane, the slope is limited to'/2:12.
4When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and
IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable.
ESR -1463 1 Most Widely Accepted and Trusted Page 9 of 10
TABLE 4—WIND RESISTANCE - MECHANICALLY FASTENED ASSEMBLIES°''
SYSTEM
MAXIMUM
DECK'
INSULATION
MEMBRANE
MEMBRANE
MAXIMUM
MAXIMUM
NO.
ALLOWABLE
FASTENING
FASTENER
FASTENER
WIND UPLIFT
SPACING
ROW
(Psf)
(inches)
SPACINGS
Foam plastic
insulation'•2-
1
45
Noncombustible
'/cinch-thiick
fiberboard or
Sure -Tough
HP -X Fastener &
Metal Fastening Bar
12
6 ft 6 inches
barrier board
(See Sect. 3.6)
2
75
Noncombustible
Same as System No. 1
Sure -Tough
HP -X Fastener &
6
6 ft 6 inches
Metal Fastening Bar
3
52
Noncombustible
Same as System No. 1
Sure -Tough
HP Fastener &
6
9 ft 6 inches
Polymer Seam Plate
4
45
Noncombustible
Same as System No. 1
Sure -Tough
Sure -rite Fastener &
12
9 ft 6 inches
ST Fastening Bar
5
30
Noncombustible
Same as System No. 1
Sure -Tough
HP Fastener &
12
9 ft 6 inches
(75 mil)
Polymer Seam Plate
6
60
Noncombustible
Same as System No. 1
Sure -Tough
HP Fastener &
6
9 ft 6 inches
(75 mil)
Polymer Seam Plate
Sure -Weld,
HP -X or HP -Xtra
7
45
Noncombustible
Same as System No. 1
Sure -Weld EXTRA, or
Fasteners with Piranha
12
7 ft 6 inches
Spectro-Weld
or Piranha Xtra Plates
8
45
Noncombustible
Same as System No. 1
Sure -Weld,
Sure -Weld EXTRA, or
HP -Xtra Fasteners with
12
9 ft 6 inches
Spectro-Weld
Piranha Xtra Plates
Sure -Weld,
HP -X or HP -Xtra
9
60
Noncombustible
Same as System No. 1
Sure -Weld EXTRA, or
Fasteners with
Piranha or Piranha Xtra
6
9 ft 6 inches
Spectro-Weld
Plates
Sure -Weld,
HP -X or HP -Xtra
10
67
Noncombustible
Same as System No. 1
Sure -Weld EXTRA, or
Fasteners with Piranha
6
7 ft 6 inches
Spectro-Weld
or Piranha Xtra Plates
Sure -Weld,
HP -X or HP -Xtra
11
30
Noncombustible
Same as System No. 1
Sure -Weld EXTRA, or
Fasteners with Piranha
12
11 ft 6 inches
Spectro-Weld
or Piranha Xtra Plates
Sure -Weld,
HP -X or HP -Xtra
12
60
Noncombustible
Same as System No. 1
Sure -Weld EXTRA, or
Fasteners with Piranha
6
11 ft 6 inches
Spectro-Weld
or Piranha Xtra Plates
13
53
Noncombustible
Same as System No. 1
Sure -Flex
HP -X Fasteners with
6
6 It 4 inches
Piranha Plates
14
83
Noncombustible
Same as System No. 1
Sure -Flex
HP -X Fasteners with
Piranha Plates
6
2 It 11 inches
HP -X or HP -Xtra
15
30
Noncombustible
Same as System No. 1
Sure -Flex
Fasteners with Piranha
18
6 It 4 inches
or Piranha Xtra Plates
HP -X or HP -Xtra
16
45
Noncombustible
Same as System No. 1
Sure -Flex
Fasteners with Piranha
12
6 ft 4 inches
or Piranha Xtra Plates
17
53
Noncombustible
Same as System No. 1
Sure -Flex
HP -X Fasteners with
12
2 ft 11 inches
Piranha Plates
18
45
Noncombustible
Same as System No. 1
Sure -Weld
HP -X Fasteners with
1 per 5.3 ffz
N/A
OMG RhinoBond Plates
19
60
Noncombustible
Same as System No. 1
Sure -Weld
HP -X Fasteners with
1 per 4 ft2
N/A
OMG RhinoBond Plates
For SI: 1 inch = 25.4 mm; 1 ft = 0.305 m; 1 psf = 47.88 Pa.
'Foam plastic insulation must be any of the following (1 -inch min. to 6 -inch max. thickness): Carlisle "SecurShield Polyiso","Polyiso HP -H"
Hunter Panels "H -Shield" or Hunter Panels "H -Shield- CG".
2All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in
accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less.
'Steel deck must be minimum No. 22 gage galvanized steel [base -metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum
compressive strength (fc) of 2500 psi. See Section 5.6 of this report.
°For existing metal roofing, the assemblies listed must be installed by fastening through the roofing and into structural members (purlins, angle
iron, beams, etc.) capable of resisting all expected loads. The maximum allowable wind uplift (field) pressures are shown in Column 2.
'UL Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanu rate insulations (max slope1:12) or below
min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks.
SCarlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When
these two boards are used directly below the Sure -Weld membrane, the slope is limited to'/2.12.
ESR -1463 1 Most Widely Accepted and Trusted Page 10 of 10
Table 4 footnotes cont'd
When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and
IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable.
a Fastener row spaces shown are for field of roof only. See Section 4.3 for recognized fascia systems for mechanically fastened roof
assemblies. The maximum allowable load for Carlisle SecurEdge 300 is 234 pit (348 kg/m). The maximum allowable load for Carlisle
SecurEdge 3000 is 200 plf (298 kg/m). Distance between the edge of the roof and the first row of fasteners must be determined accordingly
TABLE 5—WIND RESISTANCE — ADHERED ASSEMBLIES5
SYSTEM
ALLOWABLE
DECK2
INSULATION /MIN. THICKNESS'''
INSULATION
MEMBRANE
NO.
WIND UPLIFT
FASTENING
TYPE
(FIELD) (psf)
RATE
1
45
Combustible or
1/2 inch fiberboard °,15/32 inch OSB, or barrier board (See
1er 2 f?
p
EPDM, PVC and TPO
Noncombustible
Section 3.6)
Membranes
2
45
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter
Panels "H -Shield" or "H -Shield -CG" / 1.4 inch
1 3.2 ft2
EPDM PVC and TPO
Noncombustible
Securock
per
Membranes
with'/Tinoh coverboard (optional)
3
45
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter
Panels "H -Shield" or "H -Shield -CG" /2.0 inch
1 4 ft2
EPDM, PVC and TPO
Noncombustible
%-inch
per
Membranes
with Securock coverboard (optional)
4
68
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso", Hunter
FAST Adhesive
FleeceBACK Membranes
Noncombustible
Panels "H -Shield" or "H -Shield -CG"/ 1.0 inch
5
75
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter
Panels "H -Shield" or "H -Shield -CG" / 2.0 inch
1 1.6 ft2
EPDM PVC and TPO
Noncombustible
with'/zinch Securock coverboard (optional)
per
Membranes
6
120
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; HunterTPO
"H "H
1 per 1 It,
Membranes;
EPDM membranes (with
Noncombustible
Panels -Shield" or -Shield -CG"/ 2.0 inch
noncombustible deck only)
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter
7
128
Noncombustible
Panels "H -Shield" or "H -Shield -CG" / 2.0 inch
1 per 1 ft2
EPDM and TPO Membranes
with'/2-inch Securock coverboard (optional)
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter
8
135
Noncombustible
Panels "H -Shield" or "H -Shield -CG" / 2.0 inch
1 per 1 ft2
FleeceBACK Membranes
with 1/2 -inch Securock coverboard (optional)
9
143
Combustible or
'/2 inch DensDeck Prime
1 per 1 ft2
FleeceBACK Membranes
Noncombustible
For SI: 1 inch = 25.4 mm; 1 ft = 0.305 m; 1 psf = 47.88 Pa
'All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in
accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less.
2Steel deck must be minimum No. 22 gage galvanized steel [base -metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum
compressive strength (V.) of 2500 psi. See Section 5.6 of this report.
3UL Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanu rate insulations (max slopel:12) or below
min. '/z -inch -thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks.
°Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When
these two boards are used directly below the Sure -Weld membrane, the slope is limited to 1/2:12.
SWhen application is over existing roofs, documentation of the wind -uplift resistance of the composite roof construction must be submitted to
the code official for approval at the time of permit application. For reroofing or recovering, installation must be in accordance with IBC Section
1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable.
ESR -1463 I Most Widely Accepted and Trusted Page 5 of 10
option .l.
Vt
Sy.-ild. las.
.14s
ZkYLM.,
'*I%k : 0007''
"L Dif 'o i, C:rAjhM Ali -Cpimlfl.z
FIGURE 1—INSPECTION AGENCY LABEL
ESR -1463 I Most Widely Accepted and Trusted Page 6 of 10
TABLE 1—PRODUCT NAMES
CARLISLE PRODUCT
MULE -HIDE PRODUCT
WEATHERBOND PRODUCT
VERSICO PRODUCT
KELLY CO./
NAME
NAME
NAME
NAME
2001 INC.
PRODUCT NAME
Sure -Seal
Mule -Hide Standard
WeatherBond RBR EPDM
Versigard
EPDM
Membrane
Sure -Seal FR
Mule -Hide FR EPDM
WeatherBond RBR FR EPDM
Versigard Nonreinforced
C-EPDM-C
Membrane
EPDM
Sure -Tough Reinforced
Mule -Hide Standard
WeatherBond RBR Standard
Versigard Reinforced
C-EPDM-CR
Reinforced EPDM
Reinforced EPDM Membrane
Sure -Tough FR
Mule -Hide FR Reinforced
VersigardFR Reinforced
C-EPDM-CR Type 1
Reinforced
EPDM
Sure -White
Mule -Hide White -on-
WeatherBond RBR White EPDM
Versigard Nonreinforced
EPDM RF - White
Black EPDM
Membrane
EPDM -White
Sure -Weld
Mule -Hide TPO-c
WeatherBond PRO TPO
Versiweld
Reinforced TPO /White
Membrane
TPO
Sure -Weld HS
Mule -Hide TPO-c (FR)
Versiweld ES
SAT-TPO
Mule -Hide SA-TPO
WeatherBond PRO PAS TPO
Versiweld QA TPO
Sure -Weld EXTRA
Mule -Hide TPO-c Extra
WeatherBond PRO TPO
Versiweld PLUS
Membrane
Sure -Weld HS EXTRA
Mule -Hide TPO-c Extra
Versiweld ES PLUS
(FR)
Sure -Weld Fleece BACK
Mule -Hide TPO-c Fleece
Versiweld VersiFleece
Baric
Sure -Flex
Mule -Hide PVC
WeatherBond PRO PVC
VersiFlex Reinforced
Membrane
PVC Membrane
Sure -Flex FRS
Mule -Hide FRS PVC
VersiRex FRS
Membrane
-
Reinforced PVC
Membrane
Sure -Seal 90-8-30A
Mule -Hide Bonding
WeatherBond RBR LC -60 Bonding
G200SA Yellow
2001 Inc. Bonding
Bonding Adhesive
Adhesive
Adhesive
Substrate Adhesive
Adhesive
Sure -Seal Aqua Base 120
Mule -Hide Water -Based
Aqua Base 120 Bonding Adhesive
Aqua Base 120 Bonding
Bonding Adhesive
Bonding Adhesive
Adhesive
Sure -Weld Bonding
Mule -Hide TPO-c
WeatherBond PRO TPO Bonding
Versiweld Bonding
Adhesive
Bonding Adhesive
Adhesive
Adhesive
Sure -Weld Low VOC
Mule -Hide TPO-c Low
Versiweld LOW VOC
Bonding Adhesive
VOC Bonding Adhesive
Bonding Adhesive
Sure -Flex PVC Bonding
Mule -Hide PVC Bonding
WeatherBond PRO PVC Bonding
VersiFlex PVC Bonding
Adhesive
Adhesive
Adhesive
Adhesive
Sure -Flex Low VOC PVC
Mule -Hide Low VOC
VersiFlex Low VOC PVC
Bonding Adhesive
PVC Bonding Adhesive
Bonding Adhesive
FAST 100 Adhesive
Mule -Hide SP -100
FAST 100 Adhesive
Adhesive
FAST 100 LV Adhesive
Mule -Hide SP -100 -LT
FAST 100 LV Adhesive
Adhesive
DEraDECK PR1ME'/DENsDECW
COVER BOARD
DISTRIBUTED BY CARLISLE
u Features and Benefits
Overview
DensDeck and DensDeck Prime are exceptional fire barriers, thermal
barriers and cover boards used in various commercial roofing systems.
The patented design employs glass mat facers on the top and bottom.
They are embedded into a gypsum core to provide excellent fire
resistance, moisture resistance and wind uplift properties. They have also
been shown to withstand deterioration, warping and jobsite damage.
These products are FM Approved and the only 1/2" gypsum product to
meet the calorimeter requirements for conventionally insulated decks.
Tested in accordance with ASTM E84, its surface burning characteristics
are Flame Spread -0 and Smoke Developed-O.DensDeck or DensDeck
Prime (5/8" thick) can replace any generic Type X gypsum board
in any roof assembly in the UL Fire Resistance Directory under
the prefix "P".
Intended Uses
DensDeck Prime is typically used in fully adhered EPDM and TPO
applications as an overlayment board in lieu of high-density wood
fiberboard over insulations such as extruded polystyrene or EPS.
it is compatible with solvent based bonding adhesives and over
polyisocyan u rate insulation when additional compressive strength
is desired. Additionally, DensDeck Prime is used as a base layer for
Carlisle's 725TR Air and Vapor Retarder, in conjunction with CCW
702 -LV Primer or Cav-Grip, on applications where Carlisle FASTTM
Adhesive is used to attach insulation and a vapor retarder is specified.
It is also compatible with hot asphalt and can be used as a membrane
undedayment on the Hot Mopped Roofing System or as a parapet wall
substrate for all systems.
DensDeck is used primarily in mechanically fastened roofing applications
as an overlayment board in lieu of high density wood fiberboard over
insulations such as extruded polystyrene or EPS. DensDeck can also
be used over polyisocyanurate insulation when additional compressive
strength is desired for roofs subjected to increased foot traffic or for
increased resistance to hail damage. It is also heavily used in wood
deck constructions to achieve UL/FM Approvals fire ratings. DensDeck
reduces the growth of mold and mildew per ASTM D 3273.
InmMig in hoofing Sohftns for fter 45 Bars
800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-
• Superior UL code ratings available for high slopes and wood decks
• Cover board improves resistance to foot traffic and hail damage
• Reduced fastening densities provide labor savings
• Superior FM Approvals wind uplift ratings
Installation
DensDeck or DensDeck Prime may be fastened in accordance with
an approved fastening pattern (see reverse) or secured with FAST
Adhesive or mopped with Type III or IV Asphalt.
Edge joints should be located on and parallel to deck ribs. End joints of
adjacent lengths should be staggered.
1. Shall be installed with ends and edges butted tightly
2. Where installed over combustible wood decks or insulations, all
joints should be staggered
3. In accordance with approved shop drawings, FM Approved
fasteners shall be installed with plates through the roof board,
flush with the surface
4. When attaching Carlisle 725TR Air and Vapor Retarder, use
only DensDeck Prime in conjunction with CCW -702, 702 -LV or
Cav-Grip Primers.
Precautions
1. Panels must be kept dry before, during and after installation.
Apply only as much roof board as can be covered by the roof
membrane system in the same day
2. When applying solvent -based adhesives or primers, allow
sufficient time for the solvent to flash off to avoid damage to
polystyrene roofing components
3. 1/4" thick DensDeck is not recommended for vertical parapet
applications
4. DensDeck or DensDeck Prime is not permitted as the
membrane undedayment for ballasted roofing systems
Technical Data
• Manufactured to conform to ASTM C 1177
• Tested in accordance with ASTM E-84 or CAN/ULC-S102.
Non-combustible when tested in accordance with ASTM E 136
• DensDeck Prime: UL Classified when tested in accordance with
ASTM E 119
Carlisle SynTec
�"�j
I
DENsDEcK
�
C01MR
BOMW
III III' BY CARLISLE
DensDeck Prime Cover Board
fastening criteria to conform with FM .
Approvals ratings on Carlisle SynTec
Fully Adhered Roofing Systemsp)mm
Notes:
1. For wind uplift/FM Approvals compliance where
DensDeck Prime Cover Board is mechanically
attached to metal decks. These products shall
be installed to the specifics of the FM Approvals
design assembly.
2. Contact Carlisle for fastening density requirements
for other FM Approvals ratings available.
3. Metal insulation fastening plates must be used
with their corresponding FM Approvals -approved
fastener.
4. Refer to FM Approvals Property Loss Product
Data Sheet 1-29 for perimeter and
corner enhancements.
FM Approvals 1-901/4" or 1/2" DensDeck Prime Cover Board
0 0 0
O O 1 O
i
12"
t2.
48'
12'
1T
12' 24 24 24' 12'
4'x 8' Boards
(12 fast. per 4' x 8' board)
FM Approvals 1-90 5/8" DensDeck Prime Cover Board
4'x 8' Boards
(8 fast. per 4'x 8' board)
Invesfing in Roofing S01000S for 0Vff 45 Years
800-479-6832 a P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 v www.carlisle-syntec.com
Cadlsle and FAST are bademmft of Cantle. DensDeck and DemDedc Rime are tradamarkc of Ceoga P=ft.
REPRINT CODE: 601486 - "DensDeck Roduot Data Sheet" -120710 0 2010 Cadtsle. Carlisle SynTec
.; . +L
i
E3 [ill
WIH�.
ROOF CONSTRUCTORS
Wednesday, August 21, 2013
Commercial Construction Consulting, Inc.
313 Congress St #202
Boston, MA 02210
Attn: Mr. James Cisz
Re: Mountain Dunes, Equipment Well Re -Roofing
This proposal is in regard to the above referenced project. We are proposing the
new low -slope roofing system. Furnishings and installations will be as explained below;
Demolition & Clean Up: RDW will remove the low -slope roofing system down to the
original underlayment. All fasteners from the existing roofing system will be pulled
from the substrate, this will give a cleaner surface for the preparations of the new roofing
system and will in sure that the old fasteners will not puncture the new material. All
roofing debris on the ground will be swept up and the grounds will be rolled with a
magnet to pick up any fasteners or metal scraps that had fallen during the demolition.
RDW will dispose of all roofing waste
Dens Deck: This product is used as an underlayment for the Thermoplastic Polyolefin
(TPO) roofing systems. The Dens Deck will provide a clean surface for the new roofing
system. Dens Deck is a '/4" roof board that consists of a moisture resistant,
noncombustible core of specially treated gypsum with glass mat facing. This material
provides a class "A" fire rating while its strength helps against wind uplift. The Dens
Deck will be fastened to the substrate using 3" plates and 2" fasteners. The fasteners will
be installed in an I-90 pattern giving a 90mph wind rating.
P.O. Box 476, Thousand Palms, California 92276 • (760) 322-5144 Fax (760) 322-5244
Lic. #688062
1:3 ID
WINKLEcO
ROOF CONSTRUCTORS
Thermoplastic Polyolefin (TPO): This is a single ply mechanically attached roofing
system. We will be installing a 60mil-reinforced membrane that will be 8' or 10' by
100' roll. This allows us to have less field seams and end lap seams than your typical
built-up roofs. This is a sure weld membrane meaning that all seams are heat welded
together, compared to either hot tar in a built up roof or an open flame used in torch on
roofs. The field will be seamed with a robotic heat welder giving a continuous and
consistent weld Details, such as flashings and corners will be welded by hand. Welds
will then be checked with a probe. The product is much safer, cleaner, and does not
produce any unpleasant odor when being installed Other positives to this roofing
system are that the TPO membrane is highly reflective and helps reduce energy
consumption cost, it will provide a long term resistance to the punishing ultraviolet
rays we receive here in the western states. This system meets California Title 24
specifications. The TPO roofing system will be installed to the manufactures
specifications. This roofing system meets the specifications for a Manufacture 20 year
No Dollar Limit (NDL) Warranty.
Flashings and Corner Details: All vent pipe flashings will receive a pre -manufactured
TPO boot flashing, the collars will be sealed with cut off mastic and hose clamps. All
inside and outside corner details will receive pre -manufactured non -reinforced TPO
corners. All flashings and corners will be hand welded and check with probes.
Sheet metal: RDW will supply and install the following sheet metal; Platform caps,
Sleeper caps, Scuppers, Counter Flashing, T Top vents and vent pipe flashings as needed.
If other sheet metal is desired to be installed by RDW there will be an additional cost.
Otherwise all other sheet metal is to be supplied by and installed by others.
Equipment Removal and Reinstallation: All AC units, Swamp Coolers and Blowers
will be removed and reinstalled. All equipment curbs will be raised to a minimum of 8".
The large Swamp Cooler is badly damaged, RDW is not responsible for further damaged
to this unit during removal and reinstallation. RDW recommends replacing this unit.
P.O. Box 476, Thousand Palms, California 92276 • (760) 322-5144 Fax (760) 322-5244
Lic. #588062
T
DID
WINKLE��
ROOF CONSTRUCTORS
Electrical Lines and Conduit: All the electrical to the equipment will be disconnected
and reinstalled. Any lines not installed in conduit that are required will be re -ran into new
conduit.
Plumbing: All plumbing will be disconnected from the equipment and reinstalled. All
damaged vent pipes above the substrate will be repaired. All plastic drainage lines from
the equipment that are required to be copper will be replaced.
Damaged Plywood & Fascia: Damaged plywood, board or other substrate will need to
be replaced. If damaged plywood exceeds 1,000 sq.ft. RDW can remove and replace any
damaged plywood sheeting at $ 65.00 per sheet. Other substrates will be removed and
replaced at a time and material based cost.
Equipment Well Re -Roofing: $ 18,819.00
Respectfully Submitted,
Ryan A. Winkle
Supervisor/Estimator
P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244
Lic. #688062