Loading...
04-3602 (AR)f .. i� BUILDING & SAFETY DEPARTMENT J1504 (760).777 '7012 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT Application Number X04-00.003602 Date" 5/03/04 Property Address 80175 VIA VALEROSA APN: 772-250-9.99-22 -30357 - Application description ADDITION - RESIDENTIAL Property Zoning . . . . . . LOW DENSITY RESIDENTIAL Application valuation 34098 Owner Contractor BILL WATERS FORD,.JOHN MARSHALL 80-175 VIA VALEROSA 43255 SILKTREE LANE. _LA QUINTA CA 92253 PALM DESERT. CA 92260 (760). 771-5870 (760) 285=8963 WCC: NONE WC: EXEMPT 09/30/04 CS:LB:, 621206 09/30/04 CCC: B ------ Structure Information '.422,SQ. .FT. CASITA ADD. --.-- Construction Type . . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/LONG.<=10 Flood Zone. . . . . . . . . NON -AO FLOOD ZONE* Other struct info CODE EDITION 2001 CBC # BEDROOMS 1..00 FLOOD'ZONE. NO . FIRST FLOOR SQ FTG 422:00 Permit . . . . . BUILDING PERMIT Additional desc .` Permit Fee 317.00 Plan Check Fee 206.05 Issue Date Valuation . . . X34098 Qty Unit Charge Per Extension BASE. FEE 252.00 10.00 6'.5000 THOU BLDG 25,001=50,.000 65.00 Permit --------------- ELEC-MISCELLANEOUS Additional desc . Permit Fee 15.00 Plan Check Fee 3.75 Issue Date Valuation . . 0 Qty ..Unit.Charge Per Extension BASE FEE 15.00 Permit. ------------------------------------------------ MECHANICAL P.O. Box 1504 VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: - 0 I Date: S .3- Am licant• P C.oN�� C%ti Applicant's Mailing Address: Architect or Engineer: K. AA. KA, P/'llN i IJAYANA U Architect or Engineer's Address: 'Ir // E sv,-�.✓y zuwe-5 �f 69. t;r• 5?4, 6j s CA Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of peri'ury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the. Business and Professionals Code, and my License is in full force and effect. License Class ( License No. =:_ . Date Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property.who builds or improves thereon, and who.does the work himself or herself or through his or her own employees, provided that the improvements are. not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1, as owner of the property, am exclusively co cling with licensed contractors to con the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to a ner of property who builds o 'mp /, a n, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License law. U I am exempt under Sec. reason Date CnN r 4 /eclarations: ORKERS' COM ENSATION DECLARATION hereby affirm under penalty of perjury one of the fo lowi _ I have and will maintain a certificate of n t to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issue . —I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: pCamer V'Policy Number _ 1r� I certify that, in the performance of ork for which this permit is issued, I shall of plo ny person in any manner so.as to become subject to the workers' TT compensation laws of Califom' , and agr hat, if I should sub'ect t o compensation provisions of Section 3700 of the Labor Code, I shall fort ' comply with those ovi ' s /DateD IAPPlican `� . WARNI G: AILURE TO SECURE WORKERS' COMPEN fjT COVERAGE IS U W FUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINE UP TO ONE HUNDRED THOUSAND DOLLA 00,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is.a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes nulla,pd void if work is not commenced within 180 m date of issuance of such permit, or cessation of work for 180 days will subject permit to cancell n. 1 certify that I have read this application and state that the above info alio correct. 1 agree to m with al and my ordinances and state laws relating to building constructi n, and ereby authorize representatives of this county e r o above -me r rt o ' n purposes. r Signature (Applicant or Agen Page 2 Application Number . . . . . 04-00003602 Date 5/03/04 ------------------------------------------------------------------------------- Permit . . . . . . MECHANICAL, Additional desc Permit Fee . . . 39.5D Plan Check Fee '9.88 Issue Date. Valuation . . . . 0 Expiration Date 12/03/C4 Qty Unit Charge Per Extension BT SE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=10.0K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 6.5000 EA MECH VENT FAN 6.50 Permit . ... . . . PLUMBING Additional desc Permit -Fee . . . . 58.50 Plan Check Fee 14.63 Issue Date . . . . Valuation . . . . 0 Expiration Date 11/03/D4 Qty' Unit Charge Per Extension BASE FEE 15.00 5.00 6.0000 EA PLB FIXTURE 30.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3..0000 EA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA FLB GAS PIPE 1-4 OUTLETS 3.00 ------------------ 7 ----------------------------------------- ---.-------------- Special Notes and Comments 422 SQ. FT. CASITA PER APPRCVED PLANS. ---------------------------------------------------------------------------- Other Fees . . . . . . ART IN PUBLIC PLACES -RES .00 ENERGY REVIEW FEE 20.61 STRONG MOTION (SMI) - RES 3.40 Fee summary Charged Paid Credited Due. Permit Fee Total 430.00 .00 .00 430.00 Plan'Check Total 234.31 .00 00 234.31 Other Fee Total .24. 01 .0.0 .. .00 1 Grand Total 688.3? .00 .00 688.32 o� 0000 } TITLE 24 REPORT f Title 24 Report for: Mr. & Mrs. Bill'Waters-Casita 8.0-175 Via Valerosa La Quinta, Ca 92253 Project Designer: Robert A Pitchford, Design & Drafting 41-625 Eclectic, #A2 Palm Desert, Ca 92260 (760) 346-2856 Report .Prepared By: Tim Scott H & H Air Conditioning 74-991 Joni Drive #20 Palm Desert, CA 92260-2043 (760) 340-3088 CITY OF LA QUINT BUILDING & SAFETY DP • AO MQ nV i FOR CONST GT10N Job Number:SAT � 1 0 e I ; Date: 4/19/04 The EnergyPro computer program has been used to perform.the calculations summarized in this compliance report. This program has approval and is ( authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 ByfnergySoft Job Number: User Number: 5533 r TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form. MF -1 R Mandatory M.easures.,Checklist 6 Form C -2R Computer Method Summary 8 HVAC System Heating and Cooling Loads Summary 12 Room Load Summary 13 Room Heating Peak Loads 14 Room Cooling. Peak Loads 15 EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Mr.. & Mrs. Bill Waters-Casita 4/19/04 Project Title Date 80-1.75 Via Valerosa La Qu,inta P7rojecFA Building Permit H & H Air Conditioning (760) 340-3088 Plan Check I Date ocumen a ion u orTelephone Computer Performance 15 neia checka e Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 422.f? Average Ceiling Height: 9.0 ft Total Conditioned Slab Area: 422 ft2 Building Type: (check one or more) Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building F] Multi -Family ❑Existing Plus Addition Front Orientation: (East) 90 deg Number of Dwelling Units: 1.00 Number of Stories: 1 ING SHELL INSULATION Component Type R-38 Roof (R.38.2x14.16) R-19 Wall (W.19.2x6.16) Slab On Grade Slab On Grade FENESTRATION Floor Construction Type: 0 Slab Floor Const. Frame Assembly Type U -Value Wood 0.028 Wood 0.065 rtia 0:756 Na 0.756 ❑ Raised Floor Location/Comments (attic, garage, typical, etc.) Exterior Roof Exterior Wall Covered Slab w/R-0.0 Perimeter Insulation Exposed Slab w/R-0.0 Perimeter Insulation Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No .Yes / No .Right. (North) 26.7 0.72 0.67 Bug Screen ❑X❑ ❑ x❑ Front (East) 30.0 0.87 0.67 Bug Screen ❑ X❑ ❑ X❑ Front (East) 24.0 0.55 0.65 Bug Screen ❑ ] ❑ ] 'Left (South) 10.5 0.72. 0.60 Bug Screen ❑ x❑ ❑ ❑x 1:1-1:1 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 04/19/04 08:48:26 Run Code: 1082389706 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:3 of 15 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Mr. & Mrs. Bill Waters-Casita 4/19/04 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat. Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Split Heat Pump. 7.30 HSPF Ducts in Attic 4.2 Setback HVAC -1 4 Cooling Equipment Minimum Duct Type (air conditioner, • Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments ' Split Heat Pump 11.0 SEER Ducts in Attic " ' 4.2 Setback HVAC -1 ' WATER HEATING SYSTEMS Rated 1 Tank Energy Fact' 1 Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby ..System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) Standard Gas 50 gal or Less Small Gas, Standard 1 40,000 50 0.52 n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Stu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS 'OMPLIANCE STATEMENT External Tank Insul. R -Value 12 This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Tim Scott Title/Firm: Robert A Pitchford, Design & Drafting • Title/Firm: H & H Air Conditioning ..Address: 41-625 Eclectic, #A2 Address: 74-991 Joni Drive #20 Palm Desert, Ca 92260 Tele pho 0 4 28 Lic. # Inignatur ate) forcement Agency Name: Title/Firm: Address: Telephone: . Run Initiation Time: '04/19/04 3.1 By EnergySoft User Number: 5533 Palm Desert, CA 92260-2043 Telephone: (760) 340-,3088 4-1 ilcg— (signature) (da e) signature stamp date !6 Run Code: 1082389706 Job Number: PageA of 15 t Certificate of Compliance: Residential (Addendum) CF -IR Mr. & Mrs. Bill Waters-Casita 4/19/04 .,Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies uaaeu un use auequacy or the speciat justification and documentation submitted. Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanke . The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. an Field e: System includes Refrigerant Charge and AIrtloW Credit (6-r a . certitied HERS rater —m—u—ST—p—ro—Widd verifification of the TXV, or measuie the Refrigerant Charge and Airflow. Run IrlitiationTime: un Code: 1082389706 EnergyPro 3.1 By EnergySoft User Number: 5.533 Job Number: Page:5 of 15 Run IrlitiationTime: un Code: 1082389706 EnergyPro 3.1 By EnergySoft User Number: 5.533 Job Number: Page:5 of 15 j Mandatory Measures Checklist: Residential (Page 1 of 2) . MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable_ boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures .§150(.): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturer's labeled R. -Value. 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does F'§ not apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or'equivalent' §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no Elgreater than 2.0 pem>(nch. ® §118: Insulation specified or installed.meers insulation, quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ' 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and'16 only. ® § 1500: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. Installation Fireplaces, Decorative Gas §150(e): of Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ®§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ® § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ® § 1506): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank,. non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or. other indirect hot water tanks have R-12 external insulation or.R-16 combined intemal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 5533 Job Number: Page:6 of 15 Mandatory Measures ,Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (") may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) 150(m): Ducts and Fans u 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum' installed level of R-4.2 or enclosed entirely in conditioned space.. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth.back rubber adhesive duct tapes'unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following:. Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum; sheet'metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as.above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% tfiermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. iX] §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118 (f): Cool Roof material meet specified criteria Lighting Measures § 150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/waft or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. [X] §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3,1 . By EnergySoft User Number: 5533 Job Number: Page:7 of 15 ,Computer Method Summary (Part 1 of 3) C -2R Mr. & Mrs. Bill Waters-Casita 4/19/04 -Proj ct Ti -ti -e- a e 80-175 Via Valerosa La Quinta -Prot—endress Bui–ilding Permifl H & H Air Conditioning (760) 340-3088 P a^ Chock7Da e -Documentafw" n-- ut o� � Ieelep on—� Computer Performance 15 Rena heck/Date e Co-�iancP Pfhd IPar�Cmmnu or Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 4.27 7.77 -3.51 Space Cooling 62.24 58.63 3.61 Domestic Hot Water 43.64 43.62 0.03 Totals "0.15 110.02 0.12 Conditioned Floor Area: 422 Building Type: Single Fam Detached Building Front Orientation: (East) 90 deg Number of Dwelling Units: 1.00 Number of Stories: 1 - X❑ Slab Floor Floor Construction Type: ❑ Raised Floor Total Fenestration Area: 21.6% Total Conditioned Volume: 3,798 Slab Floor Area: 422 'BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume 'Units HVAC -1 422 3,798 1.00 OPAQUE SURFACES Act. Type Area Ll -Fac. Azm. Tilt Zone Type Sleeping Thermostat Vent Type Hgt. Area Sleeping. tat 2 n/a ----go Gains Y / N Form 3 Reference Location / Comments Run Initiation Time: 04/19/04 08:48:26 Run Code: 1082389706 EnergyPro 3.1 By EnergySoft User Number: 5533 .. Job Number: Page:9 of 15 Computer Method Summary,(Part 2 Of 3) C -2R Mr. & Mrs. Bill Waters-Casita 4/19/04 -Project Tule -Date U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 1 'Window Right (North) 7.7 0.720 0.67 0 90 Double Metal Clear Default Casita 2 Window Right (North) 11.3 0.720 0.67 0 90 Double Metal Clear Default Casita 3 . Window Right (North) 7.7 0.720 0.67 0 90 Double Metal Clear Default Casita 4 Window Front (East) 15.0 0.870 0.67 90 90 Double Metal Clear Default Casita 5 . Window Front (East) 24.0 0.550 0.65 90 90 Double NonMtl Clear Default Casita 6 Window Front (East) 15.0 0.870 0.67 90 90 Double Metal Clear Default Casita 7 Window Left (South) 10.5 0.720 0.60 180 90 Glass Block Casita 4 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin ' Right Fin # Exterior Shade Type SHGC Hggt. -VVa–. en. gt. xt. RExt. Dist. Len. R gt. Dist. Len. gt. `1—Bug Screen U.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 Bug Screen 0.76 _7� Bug Screen 0.76 Run Initiation Time: 04/19/04 08:48:26 Run Code: 1082389706 EnergyPro 3.1 By EnergySoft User Number: 5533 .. Job Number: Page:9 of 15 Computer Method Summary (Part 3 of 3) C -2R Mr. & Mrs. Bill Waters-Casita 4/19/04 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Type (sf) .(in.) Cap. Cond. Form 3 Reference R -Val. Location Comments PERIMETER LOSSES 4.2 Setback HVAC -1 F2 Insulation ' i Hydronic Piping Pipe Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 53 0.76 0.0 0 Casita Slab Perimeter 30 0.76 0.0 0 Casita HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type. (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AF(JE/HSPF)(ducts/attic, etc.) R -Value Type Comments Split Heat Pump 7.30 HSPF Ducts.in Attic 4.2 Setback HVAC -1 i Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type.(air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split.Heat Pump 11.0 SEER Ducts in Attic 4.2 Setback HVAC -1 WATER HEATING SYSTEMS . Ratedl Tank Energy Fact? 1 Tank Insul. Water Heater Water Heater Distribution . # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. Standard Gas 50 gal or Less Small Gas Standard 1 40,000 50 0.52 n/a 12 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 04119/04 08:48:26 Run Code: 1082389706 EnergyPro 3.1 By EnergySok User Number: 5533 ' Job Number: Pdge:10 of 15 C -2R Computer Method Summary (Addendum) Mr. & Mrs. Bill Waters-Casita 4/19/04 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the. items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies vu.aa. .. 1— .-4u y aJ c Ql JU-111 tiWil 011U VVb V111C111au V11 JVull IIUBV• Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. { HERS -Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS nrnvirinr Th LJ=DC #• rl.. n..... e..a4 66 t:..!A .....:c:....6;__ --A d:......_..•:_ •__•:.-_ — •1-___ _ a__.v .. r• n.. ,.•..-•...... .......�.........,. ......,. a. a.a. a....a...a ...a...a.. a.. o 4 �� "­ulnylly t— a QL111y Vl ulcac IIICaJVIQJ VII a IV1111 w -un. an Field A.he HVAC System Inc u es Refrigerant charge ana Airtlow Grean (ora 1xv A certified HERS rater mus prove verifification of the TXV, or measure the Refrigerant Charge and Airflow. Run InitiationTime: un Code: 1082389706 :nergyFro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 11 of 15 s - IHVAC SYSTEM HEATING AND COOLING LOADS SUMMARY I PROJECT NAME DATE Mr. & Mrs. Bill Waters-Casita 4/19/04 SYSTEM NAME FLOOR AREA HVAC -1 422 Number of Systems 1 Heating System Output per System 22,600 Total Output (Btuh) 22,600 Output (Btuh/sgft) 53.6 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sqft) 56.9 Total Output (sgftrron) 211.0 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sqft) 1.90 .Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions 26.0 of OutsideA .0.cfm 69.5 OF 69.5 of __(O Supply Fan 800 cfm Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM Sensible 420 8,073 0 516 9,013 0 404 451 0 0 0 0 0 0 0 0 0 404 451 8,880 0 9,914 CARRIER 38QR024C31 16,201 4,051 14,864 Total Adjusted System Output 16,201 4,051 14,864 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 69.5 of 86.9 of Heating Coil �, Return Air Ducts 14 res ng Supply Air Ducts 86.4 OF ROOMS 70.0 OF 111.0177.6 OF 74.5 l 61.5 OF 74.5 / 61.5 OF 55.4 / 54.4 OF O Supply Air Ducts JJw Outside Air 0 cfm Supply Fan Cooling Ccil 55.9154.6oF 800 cfm 48.7% R.H. ROOMS 74.5161.5 of 74.0 ! 61.3 OF Return Air Ducts EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 12 of 15 ROOM LOAD SUMMARY PROJECT NAME Mr. & Mrs. Bill Waters-Casita DATE 4/19/04 SYSTEM NAME HVAC -1 FLOOR AREA 422 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Casita asi a 1 420 8,073 0 420 8,073 0 516 9,013 PAGE TOTAL 420 8,073 0 516 9,013 TOTAL 420 8,073 0 11 516 1 9,013.1 EinergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:13 of 15 19, ROOM HEATING PEAK LOADS ProjectTitle Mr. & Mrs. Bill Waters-Casita Date 4/19/04 Room Information Design Conditions Room' Name Casita Time of Peak Jan 12 am Floor Area 422 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70 OF 656.8 Conduction A..» 11 .-o- 126../6- Items shown with an asterisk (Lc ') denote conduction through an interior surface to another room. Page Total: 9,013 Infiltration: 1.00 x 1.064 x 422 x 9.00 x 0.00 / 6GI x _ e u e it Sens.1tile Area Ceiling Reight pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,013 EnergyPro 3.1 By EnergySo, t User Number: 5533 Job Number: Page:14 of 15 422.0 X X X X x X x x x x X X X X x X x X x X X x x x X X x X x x x X X X x X X X X 0.0280 X X X X X X x x X X x X x x x X X X X X x x X x X x x X X x x X X x x X X x X 44.0 = = = = = = = = = = = = = = = = = = = = = = = = = = 520 656.8 0.0655 44.0 1,892 26.7 0.7200 44.0 846 30.0 0.8700 44.0 1,148 24.0 0.5500 44.0 581 10.5 0.7200 44.0 333 perimeter 83.0 44.5 3,694 Items shown with an asterisk (Lc ') denote conduction through an interior surface to another room. Page Total: 9,013 Infiltration: 1.00 x 1.064 x 422 x 9.00 x 0.00 / 6GI x _ e u e it Sens.1tile Area Ceiling Reight pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,013 EnergyPro 3.1 By EnergySo, t User Number: 5533 Job Number: Page:14 of 15 a t_ RESIDENTIAL ROOM COOLING LOAD SUMMARY Mr. & Mrs. Bill Waters-Casita 4/19/04 Project Title Date Room Name Casita Design Indoor Dry Bulb Temperature: 740F Design Outdoor Dry Bulb Temperature: 1120F Design Temperature Difference: 380F Conduction Area U -Value DETDBtu/hr X X x x x x 55.0 = = = = = = 650 34.6 1,487 38.0 731 38.0 992 38.0 502 38.01 287 x x x 1. Design Equivalent Temperature Difference (DETD) Page Total 4,649 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window (North) Window (North) Window (North) Window (East) Window (East) Window (East) Window (South) 15) 0.746 126 ( - 0.0 7.7 ( 0.0x X+ x1 x X x x x X x FA, + + + + + + + + + 7.7 X X x x x X x x x x 15) X X X x x )x )x )X 0.746 = = = = = = = = = = 86 ( 0.0 11.3 15) 0.746 126 ( - 0.0 7.7 15) 0.746 86 (. 0.0 1 15.0 -73)x 0.746 817 ( 0.0 1 24.0 73) 0.724 1,268 ( 0.0 1 15.0 -73)X 0.746 817 ( 0.0 1 10.5 32) 0.668 224 ( ( ( Scheid. Page Total 3,424 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 422 X 0.000 Watts/sqft xA3..413 Btuh[Watt = 0 Occupants 1.00 x 422 X 0 Btuh/occ. / sqft/occ. = 0 Receptacle 1.00 X 422 x 0.000 Watts/sgft x BtuhIVllatt = 0 Process 1.00 x 422 x 0.000 Watts/sgft xBtuhfWatt = 0 Infiltration:[ 1.00 x 1.064 X 422 x 9.00 x 0--001/ 60] 38 = 0 Sc e u e v insible CeRing Reight Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM, 8,073 Sched. Latent Gain Frac. Area Heat Gain Btulhr Occupants 1.00 x 422 x 0 Btuhlocc. I 20,000 sgft/occ. = 0 Receptacle 1.00 x 422 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process 1.00 x 422 X 0.000 Watts/sqft x 3.41 BtuhlWatt = 0 Infiltration: 1.00 x L 4,77 x . q2 x 9.00 x 0.00 / 6 0.00000 = 0 c e u e Air Latent cening eig pyy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM o EnergyPro 3.1 By EnergySoft . User Number. 5533 Job Number. Page: 15of 15 4