05-0220 (RER)P.O. Box 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING PERMIT
BUILDING & SAFETY DEPARTMENT
(760) -XT -7012
�%F
A(76077�-7011
I
INSPECTON-REQUESTS
(760) 77-7153
Qty Unit Charge Per Extension
BASE FEE 15.00
Application Number .
. . . �0:5=000002 0 3/01/05
Property Address . .
. . . . 5-04-15—VIA PUENTE
APN:
772-370-032- - -
Application description
. . . REMODEL - RESIDENTIAL
Property Zoning .
LOW DENSITY RESIDENTIAL
Application valuation
. . . . 15000
Owner
Contractor
-------------------------
HARRIS SANDRA
------------------------
SAWYER, RONALD PHILIP
.5.0415 VIA PUENTE
78525 AVENUE 41
LA QUINTA
CA 92253 INDIO CA 92201
(760) 200-0893
WCC: HRH INS
WC: 044001988704
10/01/05
CSLB: 541336
09/30/06
CCC: B
------ Structure Information
552 SQ. FT. PATIO AND FIREPLACE
-----
Construction Type . .
. . . TYPE V - NON RATED.
Occupancy Type . . .
. . . DWELLG/LODGING/LONG <=10
Flood Zone . . . . .
. . . NON -AO FLOOD ZONE
Other struct info . .
. . . CODE EDITION 2001
CBC
----------------------------------------------------
Permit . . . . . .
------------------------
BUILDING PERMIT
Additional desc
Permit Fee
162.00 Plan Check Fee
105.30
Issue Date
Valuation
15000
Qty Unit Charge
Per
Extension
BASE FEE
45.00
13.00 9.0000
THOU BLDG 2,001-25,000
117.00
------------- --------------------------------------------------------------
Permit . . . . . .
ELECT - ADD/ALT/REM
Additional desc
Permit Fee . . . .
16.50 Plan Check -Fee
4'.13
Issue Date . . . .
Valuation . . . .
0
Qty Unit Charge
Per
Extension
BASE FEE
15.00
2.00 .7500
PER ELEC DEVICE/FIXTURE 1ST 20
1.50
----------------------------------------------------------------------------
Permit . . . . . .
MECHANICAL
Additional desc
Permit Fee . . . .
24.00 Plan Check Fee
6.00
Issue Date . . . .
Valuation . . . .
0
Qty Unit Charge Per Extension
BASE FEE 15.00
P.O. Box 1504 Tif
��G�n/
78-495 CALLE TAMPICOf 4 4V a
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
Application Number:
Applicant:
Applicant's Mailing Address:
Architect or Engineer:
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date:
Architect or Engineer's Address:
Lic. No.:
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
Code, and my License is in full force and effect.
L-icense'Class ) License,No.
Date— rC� r,=
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or.that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant fora permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve.for the purpose of sale.).
1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
U I am exempt under Sec. B.& .C. for this reason
�te Owne
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier Policy Number
I certify that, in the performance of the work for which this permit is issued, I shall not employ any person In any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with t rovisions.
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name
Lender's Address
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Quinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize epresentatives of this county to enter upon the above-mentioned property r inspection purposes.
Date es a��Signature (Applicant or A7ent):
Fee summary Charged
Permit Fee Total 232.50
Plan Check Total 122.93
Other Fee Total 12.03
Grand Total 367.46
Paid Credited Due
---------- ---------- ----------
.00 .00 232.50
.00 .00 122.93
.00 .00 12.03
.00 .00 367.46
Page
2
Application Number .
. . . . 05-00000220 Date
3/01/05
Qty Unit Charge
Per
Extension
1.00 9.0000
EA MECH APPL REP/ALT/ADD
A 9.00
----------------------------------------------------------------------------
Permit . . . . . .
PLUMBING
Additional desc
Permit Fee . . . .
30.00 Plan Check Fee
7.50
Issue Date
Valuation
0
Qty Unit Charge
Per
Extension
BASE FEE
15.00
.2.00 6.0000
EA PLB ROOF DRAIN
12.00
1.00 3.0000
EA PLB GAS PIPE 1-4 OUTLETS
3.00
----------------------------------=-----------------------------------------
Special Notes and -Comments
patio addition and fireplace.3/1/05
10:0
6:46 AM jjohnson
7 -----------------------------------------------------------------------
Other Fees . . . . .
. . . . ENERGY REVIEW FEE
10.53
. STRONG MOTION (SMI) - RES
1.50
Fee summary Charged
Permit Fee Total 232.50
Plan Check Total 122.93
Other Fee Total 12.03
Grand Total 367.46
Paid Credited Due
---------- ---------- ----------
.00 .00 232.50
.00 .00 122.93
.00 .00 12.03
.00 .00 367.46
STRUCTURAL CALCULATIONS
LU z
2-: o c : a
:D �L_,�
0 LU
cz
gQO�
�z
Oz 0
z
0
Um
JOB # 05-1718-01
HARRIS RESIDENCE PATIO ADDITION
50-415 VIA PUENTE
LA QUINTA, CALIFORNIA
PREPARED FOR
MR. AND MRS. KAY HARRIS
PREPARED UNDER THE
DIRECT SUPERVISION OF:
JEFFREY B. YOUNG, S.E.
January 14, 2005
4
=s
YOUNG ENGINEERING SERVICES
CIVIL AND STRUCTURAL ENGINEERING
771804 WILDCAT DRIVE, STE. C
PALM DESERT, CA
92211
760-360-5770
VERTICAL LOADS:
ROOF:
TYPICAL (FLAT)
DEAD LOAD:
1/2"PLYWOOD
BUILT-UP ROOF
2X12 OR 2X TRUSSES @ 24" o/c
1/2" DRYWALL
INSULATION
MISC.
TOTAL
ADD 10 P.S.F. FOR STUCCOED SOFFITS
1.5
5.5
3.2
2.5
1
1.3
15.00 P.S.F.
JOB
SHEET NO. OF
CALCULATED BY
CHECKED BY
SCALE
LIVE LOAD:
>4:12
<4:12
LESS THAN 200 S.F T.A
16.00
P.S.F.
20.00 P.S.F.
201-600 S.F. T.A.
14.00
P.S.F.
16.00 P.S.F.
GREATER THAN 600 S.F. T.A.
12.00
P.S.F.
12.00 P.S.F.
WALL:
TYPICAL INTERIOR 2X4
TYPICAL EXTERIOR 2X6
DEAD LOAD:
DEAD LOAD:
2 LAYERS 5/8" DRYWALL
6.25
STUCCO
INSULATION
1.00
1 LAYERS 5/8" DRYWALL
2X4 STUDS @ 16" o/c
1.00
INSULATION
MISC.
1.75
2X12 STUDS @ 16" o/c
MISC.
TOTAL
10.00
P.S.F.
TOTAL
TYPICAL INTERIOR 2X6
DEAD LOAD:
2 LAYERS 5/8" DRYWALL 6.25
INSULATION 1.00
2X6 STUDS @ 16" o/c 1.60
MISC. 1.15
TOTAL 10.00 P.S.F.
10.00
3.13
1.00.
1.60
1.27
1 /.uu r.s.r.
• YOUING ENGINEERING SERVICES
CIVIL AND STRUCTURAL ENGINEERING JOB
77=804 WILDCAT DRIVE, STE. C SHEET NO.
PALM DESERT, CA CALCULATED BY
92211 CHECKED BY
760-360-5770 SCALE
LATERAL LOADS:
WIND: 70 M.P.H. EXPOSURE C
p=CeCgqsl=(1.06)(1.3)(12.6)(1.0)=17.36 P.S.F. 0-15' METHOD 2
p=CeCgqsl=(1.13)(1.3)(12.6)(1.0)=18.51 P.S.F. 15'-20'
p=CeCgqsl=(1.19)(1.3)(12.6)(1.0)=19.49 P.S.F. 20'-25'
SEISMIC:
Na=
1.00
R=
Nv=
1.20
hn=
Ca=
0.44
Ct=
✓ Cv=
0.77
T=Ct(hn)^.75=
BASE SHEAR:
(30-4)
V= (Cvl/RT)W=
(30-5)
V= (2.5Cal/R)W=
(30-6)
V= (.11Cal)W=
(30-7)
V= (.8ZNvl/R)W=
2001 C.B.C.
5.50 1= 1.00
12.75 Z= 0.40
0.02
0.13
1.037 W SHALL BE THIS EXCEPT
0.200 W NEED NOT EXCEED
0.048 W BUT NOT LESS THAN
0.045 W BUT NOT LESS THAN IN ZONE 4
-2-
OF
YOUNG ENGINEERING SERVICES
CIVIL AND STRUCTURAL ENGINEERING
774804 WILDCAT DRIVE, STE. C
PALM DESERT, CA
92211
760-360-5770
LOAD CASES:
STRENGTH DESIGN:
(12-1)
1 AD
(12-2)
1.2D+1.6L+.5(Lr OR S)
(12-3)
1.2D+1.6(Lr OR S)+(f1 L OR .8W)
(12-4)
1.2D+1.3W+f1 L+.5(Lr OR S)
(12-5)
1.2D+1.OE+(f1 L+f2S)
(12-6)
.9D +/- (1.OE OR 1.3W)
f1=1.00 FOR LL -100 & GARAGE
f1=.5 OTHERS
f2=.7 ROOF THAT DO NOT SHED SNOW
f2=.2 OTHERS
ALLOWABLE LOAD CASES
(12-7)
D
(12-8)
D+L+(Lr OR S)
* (12-9)
D+(W OR E/1.4)
" (12-10)
.9D +/- E/1.4
* (12-11)
D+.75[L+(Lr OR S)+(W OR E/1.4)]
* = MAY NOT USE 1/3 RD STRESS INCREASE
ALTERNATE ALLOWABLE CASES:
JOB
SHEET NO.
CALCULATED BY
CHECKED BY
SCALE
E=pEh+Ev
(12-12) D+L+(Lr OR S) Em=OMEGA Eh
"* (12-13) D+L+(W OR E/1.4)
"« (12-14) D+L+W+S/2 p= 2-20/rMAX(Ab)^.5
«« (12-15) D+L+W+S/2+W/2 1<p<1.5
«" (12-16) D+L+S+E/1.4
'* = MAY USE 1/3 RD STRESS INCREASE
-3
OF
YOUNG ENGINEERING SERVICES
JOB
CIVIL AND STRUCTURAL ENGINEERING
SHEET NO,
OF
74-804 WILDCAT DRIVE, STE. C
CALCULATED BY
PALM DESERT, CA
CHECKED BY
92211
SCALE
760-360-5770
VERTICAL LOAD DESIGN
DESIGN DATA:
LUMBER: DOUGLAS FIR -LARCH W.C.L.I.B.
GRADING
SIZE Fb psi
Fbr psi
Fv psi
Fc psi
E psi
2X4 1500
1725
95
1495
1700000
2X6 1300
1495
95
1430
1700000
2X8 1200
1380
95
1365
1700000
2X10 1100
1265
95
1300
1700000
2X12 1000
1150
95
1300
1700000
4 2X14 & WIDER 900
1035
95
1300
1700000
4X4 1500
—
95
1495
1700000
4X6 1300
—
95
1430
1700000
4X8 1200
—
95
1365
1700000
4X10 1100
—
95
1300
1700000
4X12 1000
—
95
1300
1700000 .
4X14 & WIDER 900
—
95
1170
1700000
6X6 1300
—
85
925
1600000
6X8 1300
—
85
925
1600000
6X10 1300
—
85
925
1600000
6X12 1300
—
85
925
1600000
6X14 1300
—
85
925
1600000
GLU-LAM BEAMS
MICROLAMS
PARALLAMS
24F -V4 DF/DF 24F -V8 DF/DF
TRUS JOIST
TRUS JOIST
Fb=2400 psi Fb=2400 psi
Fb=2800 psi
Fb=2900 psi
Fv=165psi Fv=165psi
Fv=285psi
Fv=290psi
E=1800000psi E=1800000psi
E=2000000psi
E=2000000psi
SIMPLE CANTILEVER
POSTS:
#1 DOUGLAS FIR -LARCH
SIZE Fb psi Fv psi
Fc psi
E psi
6X 1200 85
1000
1600000
FOUNDATION WALLS:
ASTM GRADE C-90 NORMAL WEIGHT MASONRY
BLOCK
Fm= 1500 psi
REINFORCING STEEL:
CONCRETE BLOCK
GRADE 40 GRADE 60
4
Fy=40 ksi Fy=60 ksi
LA
N
2
rn
F rr
a a
_ -0
�o
I
o Z
onA�
o 6z
6-1o�
J 0 j 2
n�
Q ru
o <
N
.a u
f
YOUNG ENGINEERING SERVICES
CIVIL & STRUCTURAL ENGINEERS
77-804 WILDCAT DRIVE, SUITE C
e�+ ces PALM DESERT, CA 92211
TEL: 760-360-5770
Rev
715. Ver
Description R1
Title: HARRIS RESIDENCE
Dsgnr: JWT Date:
Description: PATIO ADDITION
Scope
General Timber Beam
Job # 05-1717-01
General Information
Span= 29.50ft, Beam Width = 5.125in x Depth = 18.in, Ends are Pin -Pin
Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined
Section Name 5.125x18
Total Load
Center Span
29.50 ft .....Lu 0.00 ft
Beam Width
5.125 in
Left Cantilever
ft .....Lu 0.00 ft
Beam Depth
18.000 in
Right Cantilever
ft .....Lu 0.00 ft
Member Type
GluLam
Douglas Fir, 24F - V4
4.7 k
Bm Wt. Added to Loads
Allowable
Fb Base Allow
2,400.0 psi
Load Dur. Factor
1.250
Fv Allow
240.0 psi
Beam End Fixity
Pin -Pin
Fc Allow
650.0 psi
Wood Density
34.000pcf
E
1,800.0ksi
Full Length Uniform Loads
Center DL 119.00 #/ft LL 95.00 #/ft
Left Cantilever DL #/ft LL #/ft
Right Cantilever DL #/ft LL #/ft
Beam Design OK
Deflections
center span...
Span= 29.50ft, Beam Width = 5.125in x Depth = 18.in, Ends are Pin -Pin
Total Load Left Cantilever...
Dead Load
Total Load
Deflection
Max Stress Ratio
0.399 : 1
0.000 in
0.000 in
...Location
14.750 ft
14.750 ft ...Length/Deft
Maximum Moment
0.0
25.6 k -ft
Maximum Shear `
1.5
4.7 k
Allowable
D.L. Defl ) ...
64.2 k -ft
0.000 in
Allowable
@ Center
27.7 k
...Length/Defl
Max. Positive Moment
25.65 k -ft
at
14.750 ft
Shear:
@ Left
3.48 k
@. Right
Max. Negative Moment
0.00 k -ft
at
29.500 ft
Stress Calcs
@ Right
3.48 k
Max @ Left Support
0.00 k -ft
Camber:
@ Left
0.000in
Le 0.000 ft
Max @ Right Support
0.00 k -ft
Cv 0.928
Rb 0.000
@ Center
0.803 in
Max. M allow
64.22
Sxx Req'd Allowable fb
Reactions...
@ Center
@ Right
0.000 in
2,784.53 psi
fb 1,112.13 psi
tv
51.12 psi
Left DL
2.08 k
Max
3.48k
0.00 k -ft
Fb 2,784.53 psi
Fv
300.00 psi
Right DL
2.08 k
Max
3.48 k
Deflections
center span...
Dead Load
Total Load Left Cantilever...
Dead Load
Total Load
Deflection
-0.535 in
-0.896 in Deflection
0.000 in
0.000 in
...Location
14.750 ft
14.750 ft ...Length/Deft
0.0
0.0
...Length/Deft
661.6
395.04 Right Cantilever...
Camber ( using 1.5
D.L. Defl ) ...
Deflection
0.000 in
0.000 in
@ Center
0.803 in
...Length/Defl
0.0
0.0
@ Left
0.000 in
@. Right
0.000 in
Stress Calcs
Bending Analysis
Ck 19.865
Le 0.000 ft
Sxx 276.750 in3 Area
92.250 in2
Cv 0.928
Rb 0.000
Cl 0.000
Max Moment
Sxx Req'd Allowable fb
@ Center
25.65 k -ft
110.53 in3
2,784.53 psi
@ Left Support
0.00 k -ft
0.00 in3
2,784.53 psi
@ Right Support
0.00 k -ft
0.00 in3
2,784.53 psi
Shear Analysis
@ Left Support
@ Right Support
Design Shear
4.72 k
4.72 k
Area Required
15.720. in2
15.720 in2
Fv: Allowable
300.00 psi
300.00 psi
Bearing @ Supports
Max. Left Reaction
3.48 k
Bearing Length Req'd
1.044 in
Max. Right Reaction
3.48 k
Bearing Length Req'd
1.044 in
M
YOUNG ENGINEERING SERVICES Title: HARRIS RESIDENCE Job # 05-1717-01
CIVIL & STRUCTURAL ENGINEERS Dsgnr: JWT Date:
77-804 WILDCAT DRIVE, SUITE C Description: PATIO ADDITION
PALM DESERT, CA 92211 Scope
TEL: 760-360-5770
Rev: 580004
i User: KW -0601715, Ver 5.8.0. 1 -Dec -2003 General Timber Beam
I__ lc)1983.2003 ENERCALC EngineeringSoftFE ware harristecw:Calculatlons
Description R1
Query Values
M, V, & D @ Specified Locations
Moment
Shear
Deflection
@ Center Span Location = 0.00 ft
0.00 k -ft
3.48 k
0.0000 in
@ Right Cant. Location = 0.00 ft
0.00 k -ft
0.00 k
0.0000 in
@ Left Cant. Location = 0.00 ft
0.00 k -ft
0.00 k
0.0000 in
_7
YOUNG ENGINEERING SERVICES
CIVIL & STRUCTURAL ENGINEERS
77-804 WILDCAT DRIVE, SUITE C
a+ ces PALM DESERT, CA 92211
TEL: 760-360-5770
Rev: 580004
User: KW0601715. Ver!
Description R2
Title: HARRIS RESIDENCE
Dsgnr: JWT Date:
Description: PATIO ADDITION
Scope :
General Timber Beam
Job # 05-1717-01
General Information
Dead Load
Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined
Section Name 5.125x18
Max Stress Ratio
Center Span
24.00 ft .....Lu 0.00 ft
Beam Width
5.125 in
Left Cantilever
ft .....Lu 0.00 ft
Beam Depth
18.000 in
Right Cantilever
ft .....Lu 0.00 ft
Member Type
Glul-am
Douglas Fir, 24F - V4
Bm Wt. Added to Loads
Camber ( using 1.5 • D.L.
Fb Base Allow
2,400.0 psi
Load Dur. Factor
1.250
Fv Allow
240.0 psi
Beam End Fixity
Pin -Pin
Fc Allow
650.0 psi
Wood Density
34.000pcf
E
1,800.0ksi
Full Length Uniform Loads
Center DL 119.00 #/ft LL 95.00 #/ft
Left Cantilever DL #/ft LL #/ft
Right Cantilever DL #/ft LL #/ft
Beam Design OK
Span= 24.00ft, Beam Width = 5.125in x Depth = 18.in, Ends are Pin -Pin
Dead Load
Total Load Left Cantilever...
Dead Load
Max Stress Ratio
0.259 : 1
-0.234 in
-0.393 in Deflection
0.000 in
0.000 in
Maximum Moment
12.000 ft
17.0 k -ft
Maximum
Shear *
1.5
3.7 k
Allowable
65.6 k -ft
Camber ( using 1.5 • D.L.
Allowable
Deflection
27.7 k
Max. Positive Moment
16.98 k -ft
at
12.000 ft
Shear:
@ Left
2.83 k
Max. Negative Moment
0.00 k -ft
at
0.000 ft
@ Right
@ Right
2.83 k
Max @ Left Support
0.00 k -ft
Stress Calcs
Camber:
@ Left
0.000 in
Max @ Right Support
0.00 k -ft
@ Center
0.352 in
Max. M allow
65.56
Reactions...
0.000
@ Right
0.000in
fb 736.10 psi
fv
40.49 psi
Left DL
1.69 k
Max
2.83 k
Fb 2,842.58 psi
Fv
300.00 psi
Right DL
1.69 k
Max
2.83 k
Deflections
Center Span...
Dead Load
Total Load Left Cantilever...
Dead Load
Total Load
Deflection
-0.234 in
-0.393 in Deflection
0.000 in
0.000 in
...Location
12.000 ft
12.000 ft ...Length/Deft
0.0
0.0
...Length/Deft
1,228.7
733.62 Right Cantilever...
Camber ( using 1.5 • D.L.
Defl ) ...
Deflection
0.000 in
0.000 in
@ Center
0.352 in
...Length/Deft
0.0
0.0
@ Left
0.000 in
@ Right
0.000 in
Stress Calcs
Bending Analysis
Ck 19.865 Le
0.000 ft
Sxx 276.750 in3 Area
92.250 in2
Cf 0.948 Rb
0.000
Cl 0.000
Max Moment
Sxx Req'd
Allowable fb
@ Center
16.98 k -ft
71.67 in3
2,842.58 psi
@ Left Support
0.00 k -ft
0.00 in3
2,842.58 psi
@ Right Support
0.00 k -ft
0.00 in3
2,842.58 psi
Shear Analysis
@ Left Support
@ Right Support
Design Shear
3.73 k
3.73 k
Area Required
12.449 in2
12.449 in2
Fv: Allowable
300.00 psi
300.00 psi
Bearing @ Supports
Max. Left Reaction
2.83 k
Bearing Length Req'd
0.849 in
Max. Right Reaction
2.83 k
Bearing Length Req'd
0.849 in
YOUNG ENGINEERING SERVICES
CIVIL & STRUCTURAL ENGINEERS
77-804 WILDCAT DRIVE, SUITE C
en PALM DESERT, CA 92211
TEL: 760-360-5770
RCV
Ver
101983-2003 ENERCALC Enginee
Description R2
Title: HARRIS RESIDENCE
Dsgnr: JWT Date:
Description: PATIO ADDITION
Scope :
General Timber Beam
Job # 05-1717-01
Query Values
1
M, V, & D @ Specified Locations
Moment
Shear
Deflection
@ Center Span Location = 0.00 ft
0.00 k -ft
2.83 k
0.0000 in
@ Right Cant. Location = 0.00 ft
0.00 k -ft
0.00 k
0.0000 in
@ Left Cant. Location = 0.00 It
0.00 k -ft
0.00 k
0.0000 in
YOUNG ENGINEERING SERVICES Title :'HARRIS RESIDENCE Job # 05-1717-01
CIVIL S STRUCTURAL ENGINEERS Dsgnr: JWT Date:
77-804 WILDCAT DRIVE, SUITE C Description: PATIO ADDITION
6 ce9 PALM DESERT, CA 92211 Scope
_ _ TEL: 760-360-5770
Rev: 580004
i User: KW -0601715, Ver 5.8.0, 1 -Dec -2003 General Timber Beam
I
(01983-2003 ENERCAIC Engineering Software harris.ecw:Calculations
Description R3
I.General Information
Span= 23.00ft, Beam Width = 5.125in x. Depth = 18.in, Ends are Pin -Pin
Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined
Section Name 5.125x18
Total Load
Center Span
23.00 ft .....Lu 0.00 ft
Beam Width
5.125 in
Left Cantilever
ft .....Lu 0.00 ft
Beam Depth
18.000 in
Right Cantilever
ft .....Lu 0.00 ft
Member Type
GluLam
Douglas Fir, 24F - V4
3.5 k
Bm Wt. Added to Loads
Allowable
Fb Base Allow
2,400.0 psi
Load Dur. Factor
1.250
Fv Allow
240.0 psi
Beam End Fixity
Pin -Pin
Fc Allow
650.0 psi
Wood Density
34.000pcf
E
1,800.0ksi
I.Full Length Uniform Loads
Center DL 119.00 #/ft LL 95.00 #/ft
Left Cantilever DL #/ft LL #/ft
Right Cantilever DL #/ft LL #/ft
Beam Design OK
Deflections
Center Span...
Span= 23.00ft, Beam Width = 5.125in x. Depth = 18.in, Ends are Pin -Pin
Total Load Left Cantilever...
Dead Load
Total Load
Deflection
Max Stress Ratio
0.237 : 1
0.000 in
0.000 in
...Location
11.500 ft
11.500 ft ...Length/Deft
Maximum Moment
0.0
15.6 k -ft
Maximum Shear "
1.5
3.5 k
Allowable
D.L. Defl ) ...
65.8 k -ft
0.000 in
Allowable
@ Center
27.7 k
...Length/Deft
Max. Positive Moment
15.59 k -ft
at
11.500 ft
Shear:
@ Left
2.71 k
@ Right
Max. Negative Moment
0.00 k -ft
at
23.000 ft
LStress Calcs
@ Right
2.71 k
Max @ Left Support
0.00 k -ft
Camber:
@ Left
0.000 in
Le 0.000 ft
Max @ Right Support
0.00 k -ft
Cf 0.952
Rb 0.000
@ Center
0.297 in
Max. M allow
65.84
Sxx Req'd
Reactions...
@ Right
0.000in
65.54 in3
fb 676.03 psi
fv
38.45 psi
Left DL
1.62 k
Max
2.71 k
@ Right Support
Fb 2,854.71 psi
Fv
300.00 psi
Right DL
1.62 k
Max
2.71 k
Deflections
Center Span...
Dead Load
Total Load Left Cantilever...
Dead Load
Total Load
Deflection
-0.198 in
-0.331 in Deflection
0.000 in
0.000 in
...Location
11.500 ft
11.500 ft ...Length/Deft
0.0
0.0
...Length/Deft
1,396.0
833.53 Right Cantilever...
Camber ( using 1.5
D.L. Defl ) ...
Deflection
0.000 in
0.000 in
@ Center
0.297 in
...Length/Deft
0.0
0.0
@ Left
0.000 in
@ Right
0.000 in
LStress Calcs
Bending Analysis
Ck 19.865
Le 0.000 ft
Sxx 276.750 in3 Area
92.250 in2
Cf 0.952
Rb 0.000
Cl 0.000
Max Moment
Sxx Req'd
Allowable fb
@ Center
15.59 k -ft
65.54 in3
2,854.71 psi
@ Left Support
0.00 k -ft
0.00 in3
2,854.71 psi
@ Right Support
0.00 k -ft
0.00 in3
2,854.71 psi
Shear Analysis
@ Left Support
@ Right Support
Design Shear
3.55 k
3.55 k
Area Required
11.822 in2
11.822 in2
Fv: Allowable
300.00 psi
300.00 psi
Bearing @ Supports
Max. Left Reaction
2.71 k
Bearing Length Req'd
0.814 in
Max. Right Reaction
2.71 k
Bearing Length Req'd
0.814 in
ia111"I
EKN& '5_Rv
� rtav: oouuvu
User: KW0601715. Ver 5.8.0, 1•r
(c)1983.2003 ENERCALC Enginee
Description R3
values
YOUNG ENGINEERING SERVICES Title: HARRIS RESIDENCE Job # 05-1717-01
CIVIL & STRUCTURAL ENGINEERS Dsgnr: JWT Date:
77-804 WILDCAT DRIVE, SUITE C Description: PATIO ADDITION
PALM DESERT, CA 92211 Scope
TEL: 760-360-5770
re General Timber Beam
M, V, & D @ Specified Locations
Moment
Shear
Deflection
@ Center Span Location = 0.00 It
0.00 k -ft
2.71 k
0.0000 in
@ Right Cant. Location = 0.00 ft
0.00 k -ft
0.00 k
0.0000 in
@ Left Cant. Location = 0.00 ft
0.00 k -ft
0.00 k
0.0000 in
Active Fault Near -Source Zones `
Q-34 „ This map is Intended to be used In conjunction with
%., the 1997 Uniform Building Code, Tables 16-S and 16-T
Q-34
California Department of Conservation
Division of Mines and Geology
-35
LEGEND
See expanded legend and Index map
Shaded zones are within 2 km of known
seismic sources.
® A fault
PEN'SiLl W1 ISO k
�__1
\jLm i iii W-0 W, ■ -•1 = j'. \ '` '
I c rt ■� - IIII..,-PIN
B fault
Contours of closest horizonlal distance
to (mown seismic sources.
'ir' �� r�II�IEIQI���•,��
----------------
5 km
_ _
10 km
--------------
15 km
0 5
10
E
�11�I j11 �HOME
•�=� '� � '� I'll IS 1►
OKI
-35
LEGEND
See expanded legend and Index map
Shaded zones are within 2 km of known
seismic sources.
® A fault
B fault
Contours of closest horizonlal distance
to (mown seismic sources.
----------------
5 km
...........................
10 km
--------------
15 km
0 5
10
Kilometers
1/4' is approximately equal to 1 km
August, 1997
REFERENCE
m�
. . . . . . . . . . . .
Zi.� .! . . . . . . . .. . . .
.... ...........
. . . . . . . . . . . . . . . . . . . . .. .�
141
4(u.r- S(. . . . . . . . . .
Em
LDATME JOB NAME.: >��g�S 5HEET YOUNG ENGINEERING 5ERVICES
'7-1-804 WILDCAT OR. SUITE G
flS PALM DESERT, CA. 92211
JOB NO.: PH760-360-5-no FAX 7b0-360-5119
-13-
75
3 Ww=42 PLF 4 Ww=42 PLF
Ws=51 PLF Ws=51 PLF
O O
2 7' 2 8.5' �.
689# 689# 1454#
2143#
J J
a d
00 n
3 in
3 Ww=42 PLF 4 Ww=42 PLF
Ws=51 PLF Ws=51 PLF
O O
2 7' 2 8.5' �.
689# 689# 1454#
2143#
DIAPHRAGM
LINE
FORCE
WALL NO.
HEIGHT
LENGTH
UNIFORM LOAD
REMARKS
N J
1
(
I Iol
I
I t
5. (oLo
2� 9 5 z I t
�k
O N c
m_ 3 0
I
2
l�\S
2
II
t'S
�•s%Z 1kEl
I(Akcb-415
Z.
d
w A d
O n -Di 7U
d
{
rn n
n rn
N
S z
o 0
tla
Lc Ul
•
d d �
fl
fl
co co
YOUNG ENGINEERING SERVICES
JOB
CIVIL -AND STRUCTURAL ENGINEERING
SHEET NO.
OF
77-804 WILDCAT DRIVE, STE. C
CALCULATED BY.
PALM DESERT, CA
CHECKED BY
92211 PH.760-360-5770
SCALE
SHEAR WALL DESIGN
SEISMIC FACTOR = 0.214
A.B. SIZE (in.)= 0.625
A.B. CAPACITY = 1173
WALL FORCE H D
PANEL
WALL
v
No.
UPLIFT
PANEL
HOLDOWN
NO. (FT.) (FT.)
WT.
DL
PLF
A.B.
(LBS.)
TYPE
1 1615 11.0 5.7
17
119
325
2
2781
B2
HD5A/4X6/SSTB20
0.0
0.0
0.0
---------------------
TOTAL 5.7
'2 1615 11.0 1.5
17
119
578
PER MANUF.
5989
HF11X18 7/8
PER MANUF.
3 11.0 1.5
17
119
578
PER MANUF.
5989
HF11X18 7/8
PER MANUF.
0.0
0.0
TOTAL 3.0
4 689 11.0 10.0
17
0
109
2
355
A
NOT REQ'D.
0.0
0.0
0.0
TOTAL 10.0
------------------------
5 2143 11.0 1.5
17
0
1469
PER MANUF.
15842
HF11X8 1-1/8
PER MANUF.
0.0
0.0
0.0
TOTAL 1.5
0.0
0.0
0.0
0.0
TOTAL 0.0
0.0
0.0
0.0
0.0
TOTAL 0.0
0.0
0.0
0.0
0.0
TOTAL 0.0
1 6
YOUNG ENGINEERING SERVICES Title: HARRIS RESIDENCE Job # 05-1717-01
CIVIL & STRUCTURAL ENGINEERS Dsgnr: JWT Date:
77-804 WILDCAT DRIVE, SUITE C Description: PATIO ADDITION
u+ PALM DESERT, CA 92211 Scope
_ TEL: 760-360-5770
R ve _S60003
User: KW -0601715, Ver 5.8.0, 1 -Dec -2003 Plywood Shear Wall & Footing
1U1983-2003 ENERCALC Engineering Software harris:ecw:Calculations
Description SHEARWALL #1
General Information
--ode Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined
# Plywood Layers 1
Wall Length
5.660 ft
End Post Dimension
3.50 in
Plywood Grade Structural I
Wall Height
11.000 ft
Seismic Factor
0.214
Nail Size 8d
Wall Weight
17.000 psf
Nominal Sill Thick.
2.00
Thickness 3/8"
Ht / Length
1.943
Stud Spacing 16.00 in
Loads
Vertical Loads...
Overburden Load over Footing
0.00 psf
Point Load # 1 0.00 lbs
at
0.00 it
Point Load # 2 0.00 lbs
at
0.00 ft
Point Load # 3 0.00 lbs
at
0.00 ft
` Uniform Load # 1 119.00 #/ft
0.00 ft to
5.66 ft
Uniform Load # 2 0.00 #/ft
0.00 it to
0.00 ft
Lateral Loads...
Uniform Shear @ Top of Wall
325.00 #/ft
5.660 ft
= 1,839.50 lbs
Uniform Shear @ Top of Wall
0.00 #/ft
5.660 ft
= 0.00 lbs
Strut Force Applied @ Top of Wall
0.00 lbs
Strut Force Applied @ Top of Wall
0.00 lbs
Moment Applied @ Top of Wall
0.00 ft-#
Footing
Past Left Edge of Wall
3.500 ft
Concrete Weight
145.00 pcf
Wall Length
5.660 ft
Rebar Cover
3.00 in
Past Right Edge of Wall
7.000 ft
fc
3,000.00 psi
Footing Length
16.160 ft
Fy
60,000.00 psi
Footing Width
1.00 ft
Min. Steel As %
0.00140
Footing Thickness
18.00 in
Design OK
Wall Summary...
Using 3/8" Thick Structural I on 1 side/s, Nailing is 8d at 4 in @ Edges, 8d at 12 in @ Field
Applied Shear = 365.0#/ft, Capacity = 430.000#/ft -> OK
Wall Overturning = 21,480.3ft-#, Resisting Moment = 4,901.4ft-#, End Uplift = 2,929.12lbs
Max. Soil Pressures: @ Left = 1,241.4psf, @ Right = 880.4psf
Sill Bolting: 1/2" Bolts @ 27.76in, 5/8" Bolts @ 43.29in, 3/4" Bolts @ 48.00in
Footing Summary...
Max. Footing Shear = 17.24psi, Allowable = 109.54psi -> OK
Bending Reinforcement Req'd @ Left = 0.25in2, @ Right = 0.26in2
Minimum Overturning Stability Ratio = 1.601 : 1
Simpson Hold Down Options
Choices for LEFT Side of Wall to Footing..... Choices for RIGHT Side of Wall to Footing
PHD2, Capacity = 3610lbs PH D2, Capacity = 36101bs
HD5A, Capacity = 4010Ibs HD5A, Capacity = 40101bs
HD5, Capacity = 4075lbs HD5, Capacity = 4075lbs
PHD5, Capacity = 4685lbs PHD5, Capacity = 4685lbs
Al = . 2s Ir-1L%-� , I F -r = , Zs, -1z
i
7= 31 It�2 r 2S I t�2 r
YOUNG ENGINEERING SERVICES Title: HARRIS RESIDENCE Job # 05-1717-01
CIVIL & STRUCTURAL ENGINEERS Dsgnr: JWT Date:
77-804 WILDCAT DRIVE, SUITE C Description: PATIO ADDITION
eH ce9 -:PALM DESERT, CA 92211 Scope
TEL: 760-360-5770
Rev: 580003
User: KW0601715, Ver 5.8.0, 1 -Dec -2003 Plywood Shear Wall & Footing
i 101983.2003 ENERCALC Engineering Software 7 harris.ecw:Calculations
Description SHEARWALL #1
Footing Analysis
1
10.937 psi
Lateral Forces Actinq
in Direction
Soil Pressures...
To Left...
To Right...
Ecc. of Resultant @ Footing Centerline
5.262 ft
4.107 ft
Soil Pressure @ LEFT Side of Footing
1,241.40 psf
0.00 psf
Soil Pressure @ RIGHT Side of Footing
0.00 psf
880.40 psf
Moments...
Actual Mu @ Left Wall Edge
5,577.68 ft-#
12,869.85 ft-#
Actual Mu @ Right Wall Edge
2,797.59 ft-#
1,398.80 ft-#
Shears...
vu/.85 @ 'd' from Left Wall Edge
10.937 psi
- vu/.85 @ 'd' from Right Wall Edge
7.836 psi
Allowable Vn
109.545 psi
Overturning...
Overturning Moment
24,579.26 ft-#
Resisting Moment
39,362.89 ft-#
Overturning Stability Ratio
1.601 :1
2.612 psi
17.238. psi
109.545 psi
24, 579.26 ft-#
45,424.75 ft-#
1.848 :1
YOUNG ENGINEERING SERVICES Title: HARRIS RESIDENCE Job # 05-1717-01
CIVIL & STRUCTURAL ENGINEERS Dsgnr: JWT Date:
77-804 WILDCAT DRIVE, SUITE C Description: PATIO ADDITION
ek1 ces PALM DESERT, CA 92211 Scope
TEL: 760-360-5770
Rev: 580003
User: KW -0601715, Ver 5.8.0, 1 -Dec -2003 Plywood Shear Wall & Footing
(01983-2003_ENERCALC Engineering Software
Description SHEAR WALL #2 - HARDY PANEL - FOOTING DESIGN ONLY
General Information
Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined
# Plywood Layers
1
Wall Length
1.500 ft End Post Dimension
3.50 in
Plywood Grade
Structural I
Wall Height
11.000 ft Seismic Factor
0.214
Nail Size
8d
Wall Weight
17.000 psf Nominal Sill Thick.
3.00
Thickness
3/8"
Ht / Length
7.333
Stud Spacing
16.00 in
0.00 lbs
Loads
0.00 ft-#
J
Vertical Loads...
Overburden Load over Footing
0.00 psf
Point Load # 1
0.00 lbs
at 0.00 ft
1.500 ft
Rebar Cover
Point Load # 2
0.00 lbs
at 0.00 ft
fc
2,500.00 psi
Point Load # 3
0.00 lbs
at 0.00 ft
60,000.00 psi
Footing Width
Uniform Load # 1 119.00 #/ft
0.00 ft to 1.50 ft
Uniform Load # 2 0.00 #/ft
0.00 ft to 0.00 ft
Lateral Loads...
Uniform Shear @ Top of Wall
578.00 #/ft
1.500ft =
867.00 lbs
Uniform Shear @ Top of Wall
0.00 #/ft
1.500ft =
0.00 lbs
Strut Force Applied @ Top of Wall
0.00 lbs
Strut Force Applied @ Top of Wall
0.00 lbs
Moment Applied @ Top of Wall
0.00 ft-#
Footing
Past Left Edge of Wall
0.750 ft
Concrete Weight
145.00 pcf
Wall Length
1.500 ft
Rebar Cover
3.00 in
Past Right Edge of Wall
6.500 ft
fc
2,500.00 psi
Footing Length
8.750 ft
Fy
60,000.00 psi
Footing Width
2.00 ft
Min. Steel As %
0.00140
Footing Thickness
18.00 in
Design OK
Wall Summary...
Using 3/8" Thick Structural I on 1 side/s, Nailing is 8d at 2 in @ Edges, 8d at 12 in @ Field
Applied Shear = 618.0#/ft, Capacity = 730.000#/ft -> OK
Wall Overturning = 9,867.1ft-#, Resisting Moment = 344.3ft-#, End Uplift = 6,348.60lbs
Max. Soil Pressures: @ Left = 996.9psf, @ Right = 695.2psf
Sill Bolting: 1/2 Bolts @ 16.40in, 5/8" Bolts @ 25.70in, 3/4" Bolts @ 36.93in
Footing Summary...
Max. Footing Shear = 7.03psi, Allowable = 100.00psi -> OK
Bending Reinforcement Req'd @ Left = 0.50in2, @ Right = 0.50in2
Minimum Overturning Stability Ratio = 1.540 : 1
Simpson Hold Down Options
Choices for LEFT Side of Wall to Footing..... Choices for RIGHT Side of Wall to Footing
PHD8, Capacity = 6730lbs PHD8, Capacity = 6730lbs
HD8A, Capacity = 7460lbs HD8A, Capacity = 7460lbs
HD7, Capacity = 7550lbs HD7, Capacity = 7550lbs
HD1OA, Capacity = 95401 b HD10A, Capacity = 9540lbs
YOUNG ENGINEERING SERVICES Title: HARRIS RESIDENCE Job # 05-1717-01
CIVIL & STRUCTURAL ENGINEERS Dsgnr: JWT Date:
77-804 WILDCAT DRIVE, SUITE C Description: PATIO ADDITION
CHaIee PALM DESERT, CA 92211 Scope
TEL: 760-360-5.770
Rev: 580003
User KW0601715, Ver 5.8.0, 1•Dec•2003 Plywood Shear Wall & Footing
I 1U1983-2003 ENERCALC Engineering Software harris:ecw:caicuiations
Description SHEAR WALL #2 - HARDY PANEL - FOOTING DESIGN ONLY
[Footing Analysis A
Lateral Forces Acting in Direction
Soil Pressures... To Left... To Right...
Ecc. of Resultant @ Footing Centerline 2.949 ft 2.330 ft
Soil Pressure @ LEFT Side of Footing 996.87 psi 0.00 psf
Soil Pressure @ RIGHT Side of Footing 0.00 psf 695.23 psf
Moments...
Actual Mu @ Left Wall Edge
428.40 ft-#
10,392.42 ft-#
Actual Mu @ Right Wall Edge
429.48 ft-#
128.46 ft-#
Shears...
vu/.85 @ 'd' from Left Wall Edge
0.000 psi
0.000 psi
- vu/.85 @'d' from Right Wall Edge
7.028 psi
6.862 psi
Allowable Vn
100.000 psi
100.000 psi
Overturning...
Overturning Moment
11,257.69 ft-#
11,257.69 ft-#
Resisting Moment
17,340.84 ft-#
19,980.09 ft-#
Overturning Stability Ratio
1.540:1
1.775 :1
20-
YOUNG ENGINEERING SERVICES Title: HARRIS RESIDENCE Job # 05-1717-01
CIVIL & STRUCTURAL ENGINEERS Dsgnr: JWT Date:
77-804 WILDCAT DRIVE, SUITE C Description: PATIO ADDITION
PALM DESERT, CA 92211 Scope
TEL: 760-360-5770
Rev: 580003
user: KW -0601715, Ver 5.8.0, 1 -Dec -2003 Plywood Shear Wall & Footing
(01983-2003 ENERCALC Engineering software
Description SHEAR WALL #3 - HARDY PANEL - FOOTING DESIGN ONLY
General Information
Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined
# Plywood Layers
1
Wall Length
1.500 ft End Post Dimension
3.50 in
Plywood Grade
Structural I
Wall Height
11.000 ft Seismic Factor
0.214
Nail Size
8d
Wall Weight
17.000 psf Nominal Sill Thick.
3.00
Thickness
3/8"
Ht/Length
7.333
Stud Spacing
16.00 in
0.00 lbs
Loads
0.00 ft -
Footing
Vertical Loads...
Overburden Load over Footing
0.00 psf
Point Load # 1
0.00 lbs
at 0.00 ft
1.500 ft
Rebar Cover
Point Load # 2
0.00 lbs
at 0.00 ft
pc
2,500.00 psi
Point Load # 3
0.00 lbs
at 0.00 ft
60,000.00 psi
Footing Width
Uniform Load # 1 119.00 #/ft
0.00 ft to 1.50 ft
Uniform Load # 2 0.00 #/ft
0.00 ft to 0.00 ft
Lateral Loads...
Uniform Shear @ Top of Wall
578.00 #/ft
1.500ft =
867.00 lbs
Uniform Shear @ Top of Wall
0.00 #/ft
1.500ft =
0.00 lbs
Strut Force Applied @ Top of Wall
0.00 lbs
Strut Force Applied @ Top of Wall
0.00 lbs
Moment Applied @ Top of Wall
0.00 ft -
Footing
Past Left Edge of Wall
3.500 ft
Concrete Weight
145.00 pcf
Wall Length
1.500 ft
Rebar Cover
3.00 in
Past Right Edge of Wall
3.500 ft
pc
2,500.00 psi
Footing Length
8.500 ft
Fy
60,000.00 psi
Footing Width
2.00 ft
Min. Steel As %
0.00140
Footing Thickness
18.00 in
Design OK
Wall Summary...
Using 3/8" Thick Structural I on 1 side/s, Nailing is 8d at 2 in @ Edges, 8d at 12 in @ Field
Applied Shear = 618.0#/ft, Capacity = 730.000#/ft -> OK
Wall Overturning = 9,867.1ft-#, Resisting Moment = 344.3ft-#, End Uplift = 6,348.60lbs
Max. Soil Pressures: @ Left = 898.8psf, @ Right = 898.8psf
Sill Bolting: 1/2" Bolts @ 16.40in, 5/8" Bolts @ 25.70in, 3/4" Bolts @ 36.93in
Footing Summary...
Max. Footing Shear = 6.18psi, Allowable = 100.00psi -> OK
Bending Reinforcement Req'd @ Left = 0.50in2, @ Right = 0.50in2
Minimum Overturning Stability Ratio = 1.569 : 1
Simpson Hold Down Options
Choices for LEFT Side of Wall to Footing..... Choices for RIGHT Side of Wall to Footing
PHD8, Capacity = 6730lbs PHD8, Capacity = 6730lbs
HD8A, Capacity = 7460lbs HD8A, Capacity = 7460lbs
HD7, Capacity = 7550lbs HD7, Capacity = 7550lbs
HD1OA, Capacity = 95401 tis HD10A, Capacity = 9540lbs
t 2/fr-T 2 FT
2
z , l -Z4 t�Z y 1, a la
YOUNG ENGINEERING SERVICES Title: HARRIS RESIDENCE Job # 05-1717-01
CIVIL & STRUCTURAL ENGINEERS Dsgnr: JWT Date:
77-804 WILDCAT DRIVE, SUITE C Description: PATIO ADDITION
.r PALM DESERT, CA 92211 Scope
TEL: 760-360-5770
Rev: 580003
user: KW0601715. Ver 5.8.0, 1 -Dec -2003 Plywood Shear Wall & Footing
Ic11983.2003 ENERCALC Engineering Software harris.ecw:Calculations
Description SHEAR WALL #3 - HARDY PANEL - FOOTING DESIGN ONLY
Footing Analysis
vu/.85 @'d' from Left Wall Edge
6.180 psi
Lateral Forces Acting
in Direction
Soil Pressures...
To Left...
To Right...
Ecc. of Resultant @ Footing Centerline
2.708 ft
2.708 ft
Soil Pressure @ LEFT Side of Footing
898.77 psf
0.00 psf
Soil Pressure @ RIGHT Side of Footing
0.00 psf
898.77 psf
Moments...
Actual Mu @ Left Wall Edge
5,886.27 ft-#
5,886.27 ft-#
Actual Mu @ Right Wall Edge
2,797.59 ft-#
2,797.59 ft-#
Shears...
vu/.85 @'d' from Left Wall Edge
6.180 psi
vu/.85 @ 'd' from Right Wall Edge
2.612 psi
Allowable Vn
100.000 psi
Overturning...
Overturning Moment
11,257.69 ft-#
Resisting Moment
17,665.13 ft-#
Overturning Stability Ratio
1.569 :1
22-
2.612 psi
6.180 psi
100.000 psi
11,257.69 ft-#
17,665.13 ft-#
1.569 :1
YOUNG ENGINEERING SERVICES Title: HARRIS RESIDENCE Job # 05-1717-01
CIVIL & STRUCTURAL ENGINEERS Dsgnr: JWT Date:
77-804 WILDCAT DRIVE, SUITE C Description: PATIO ADDITION
ces PALM DESERT, CA 92211 scope:
TEL: 760-360-5770
Rev: 580003 plywood Shear Wall & Footing
User: KW -0601715, Ver 5.6.0, 1 -Dec -2003
(U1983.2003 ENERCALC Engineering Software harris.em:Calculations
Description SHEAR WALL #5 - HARDY PANEL - FOOTING DESIGN ONLY
General Information
Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined
# Plywood Layers 2
Wall Length
1.500 ft
End Post Dimension
5.50 in
Plywood Grade Structural I
Wall Height
11.000 ft
Seismic Factor
0.214
Nail Size 10d
Wall Weight
17.000 psf
Nominal Sill Thick.
3.00
Thickness 15/32"
Ht/Length
7.333
Stud Spacing 16.00 in
Loads
Vertical Loads...
Overburden Load over Footing
0.00 psf
Point Load # 1 0.00 lbs
at
0.00 ft
Point Load # 2 0.00 lbs
at
0.00 ft
Point Load # 3 0.00 lbs
at
0.00 ft
Uniform Load # 1 0.00 #/ft
0.00 ft
to
0.00 ft
Uniform Load # 2 0.00 #/ft
0.00 ft
to
0.00 ft
Lateral Loads...
Uniform Shear @ Top of Wall
1,469.00 #/ft
1.500ft
= 2,203.50 lbs
Uniform Shear @ Top of Wall
0.00 #/ft
1.500ft
= 0.00 lbs
Strut Force Applied @ Top of Wall
0.00 lbs
Strut Force Applied @ Top of Wall
0:00 lbs
Moment Applied @ Top of Wall
0.00 ft-#
Footing
Past Left Edge of Wall
1.000 ft
Concrete Weight
145.00 pcf
Wall Length
1.500 ft
Rebar
Cover
3.00 in
Past Right Edge of Wall
6:500 ft
pc
2,500.00 psi
Footing Length
9.000 ft
Fy
60,000.00 psi
Footing Width
3.00 ft
Min. Steel
As %
0.00140
Footing Thickness
24.00 in
---"--' ■ Design OK
Wall Summary...
Using 15/32" Thick Structural I on 2 side/s, Nailing is 10d at 2 in @ Edges, 10d at 12 in @ Field
Applied Shear= 1,509.0#/ft, Capacity= 1,740.000#/ft -> OK
Wall Overturning = 24,568.6ft-#, Resisting Moment = 210.04, End Uplift = 16,238.85lbs
Max. Soil Pressures: @ Left = 2,204.7psf, @ Right = 1,788.6psf
Sill Bolting: 1/2" Bolts @ 6.72in, 5/8" Bolts @ 10.52in, 3/4" Bolts @ 15.12in
Footing Summary...
Max. Footing Shear = 7.21 psi, Allowable = 100.00psi -> OK
Bending Reinforcement Req'd @ Left = 1.06in2, @ Right = 1.06in2
Minimum Overturning Stability Ratio = 1.228: 1 Less Than 1.5 - Warning
Simpson Hold Down Options
Choices for LEFT Side of Wall to Footing..... Choices for RIGHT Side of Wall to Footing
All Hold Downs for Post Size & Force Inadequa All Hold Downs for Post Size & Force Inadequa
Z! F T 77 -� �j , �b l rat
�Tb
i�2 r�---- 2-
- 23 -
-23-
YOUNG ENGINEERING SERVICES Title. HARRIS RESIDENCE Job # 05-1717-01
CIVIL & STRUCTURAL ENGINEERS Dsgnr: JWT Date:
77-804 WILDCAT DRIVE, SUITE C Description: PATIO ADDITION
rJ+ ces PALM DESERT, CA 92211 Scope
TEL: 760-360-5770
User: M-0601715, Ver 5.8.0, 1 -Dec -2003 Plywood Shear Wall & Footing
(01983-2003 ENERCALC Engineering Software harrKecwxalculations
Description SHEAR WALL #5 - HARDY PANEL - FOOTING DESIGN ONLY
Footing Analysis
N
Lateral Forces Acting
in Direction
Soil Pressures...
To Left...
To Right...
Ecc. of Resultant @ Footing Centerline
3.683 ft
3.492 ft
Soil Pressure @ LEFT Side of Footing
2,204.74 psf
0.00 psf
Soil Pressure @ RIGHT Side of Footing
0.00 psf
1,788.57 psf
Moments...
Actual Mu @ Left Wall Edge
552.41 ft-#
27,474.91 ft-#
Actual Mu @ Right Wall Edge
2,968.88 ft-#
456.75 ft-#
Shears...
vu/.85 @ 'd' from Left Wall Edge
• vu/.85 @'d' from Right Wall Edge
Allowable Vn
Overturning...
Overturning Moment
Resisting Moment
Overturning Stability Ratio
- 24 -
0.000 psi
6.042 psi
100.000 psi
29,095.70 ft-#
35,725.88 ft-#
1.228 :1
0.000 psi
7.211 psi
100.000 psi
29,095.70 ft-#
37,268.63 ft-#
1.281 :1