BRES2015-031178-495 CALLE TAMPICO DfUCl/
LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT
� VOJC&(.760)777-7125
F /FAX (76�0)) P7-7011
P6-( 160)1777-7153
BUILDING PERMIT
29
� VOJC&(.760)777-7125
F /FAX (76�0)) P7-7011
P6-( 160)1777-7153
Applicant: Contractor:
GABRIEL RIOS OWNER/BUILDER
49901 CINNABAR LN
COACHELLA, CA
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: _ License No.:
Date:
Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(1 I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(� I am exempt under Sec. , . B.&P.C. for this reason
Date3 a3— t (,9 Owner j7A0,1" A
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a constructioI ding agency for
the performance of the work for which this permit is issued (Sec. 3 , Civ. C.).
Lender's Name:
Lender's
Llc. No.:
3/23/2016
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: 3:1 — _�_7�_, — l kApplicant.) l
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVER E I UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CI IL F NES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS,PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes..
Datz—Z3— /C Signature (Applicant or Agent).' � C
BUILDING PERMIT
" J 2016
rymOP D
DM
Application Number:
BRES2015-0311
Owner: MpEgR
Property Address:
49725 ANACAPA CIR
LARRY & MORGAN PFEIFFER'��
APN:
646210025 -
49725 ANACAPA CIR
Application Description:
PFEIFFER RESIDENCE / REMODEL
LA QUINTA, CA 92253
Property Zoning:
Application Valuation:
$150,000.00
Applicant: Contractor:
GABRIEL RIOS OWNER/BUILDER
49901 CINNABAR LN
COACHELLA, CA
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: _ License No.:
Date:
Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(1 I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(� I am exempt under Sec. , . B.&P.C. for this reason
Date3 a3— t (,9 Owner j7A0,1" A
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a constructioI ding agency for
the performance of the work for which this permit is issued (Sec. 3 , Civ. C.).
Lender's Name:
Lender's
Llc. No.:
3/23/2016
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: 3:1 — _�_7�_, — l kApplicant.) l
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVER E I UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CI IL F NES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS,PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes..
Datz—Z3— /C Signature (Applicant or Agent).' � C
a
FINANCIAL INFORMATION
DESCRIPTION
ACCOUNT
QTY AMOUNT
PAID
PAID DATE
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400
0 $62.36
$62.36
10/2/15
PAID BY
METHOD
RECEIPT#
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID '
PAID DATE
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$17.40
$17.40
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83
$120.83
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY,
AMOUNT
PAID
PAID DATE
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$171.14
$171.14
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
Total Paid for ADDITION: $371.73 $371.73
DESCRIPTION
ACCOUNT
QTY,
AMOUNT
PAID
PAID DATE
HOURLY PLAN CHECK - YES
101-0000-42600
2
$140.00
$140.00
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY .
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
Total Paid for BLDG CITY STAFF - PER HOUR: $140.00 $140.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$6.00
$6.00
10/2/15
PAID BY
- METHOD
RECEIPT#
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $6.00 $6.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, EA ADDITION 1,000SF
101-0000-42403
0
$24.66
$24.66
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, EA ADDITION 1,000SF, PC
101-0000-42600
0
$10.16
$10.16
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$145.03
$145.03
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$47.86
$47.86
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $227.71 • $227.71
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
CONDENSER/COMPRESSOR
101-0000-42402
0
$72.52
$72.52
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
CONDENSER/COMPRESSOR PC
101-0000-42600
0
$48.34
$48.34
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
EXHAUST HOOD
101-0000-42402
.0
$12.09
.$12.09
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY .
AMOUNT
PAID
PAID DATE
EXHAUST HOOD PC
101-0000-42600
0
$4.83
$4.83
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FURNACE
101-0000-42402
0
$72.52
$72.52
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FURNACE PC
101-0000-42600
0
$48.34
$48.34
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
VENT FAN
101-0000-42402
0
$36.27
$36.27
10/2/15
PAID BY
METHOD
RECEIPT #.
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
VENT FAN PC
101-0000-42600
0
$14.49
$14.49
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
Total Paid for MECHANICAL: $309.40 $309.40
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURE/TRAP
101-0000-42401
0
$132.99
$132.99
10/2/15
PAID BY
METHOD`
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID.
PAID DATE
FIXTURE/TRAP PC
101-0000-42600
0
$132.99
$132.99
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE•
GAS SYSTEM, 5+ OUTLETS
101-0000-42401
0
$36.26
$36.26
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
GAS SYSTEM, 5+ OUTLETS PC
101-0000-42600
0
$24.17
$24.17
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WATER HEATER/VENT
101-0000-42401
0
$24.18
$24.18
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
Eoy
AMOUNT
PAID
PAID DATE
WATER HEATER/VENT PC
101-0000-42600
$14.50
$14.50
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$12.09
$12.09
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$12.09
$12.09
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
Total Paid for PLUMBING FEES: $389.27 $389.27
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, EA ADDITIONAL 500 SF
101-0000-42400
0
$108.75
$108.75
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$87.00
$87.00
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$49.31
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, FIRST 500 SF PC
101-0000-42600
0.
$134.88
$134.88
10/2/15
PAID BY
METHOD •
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
Total Paid for REMODEL: $379.94 $379.94
DESCRIPTION
ACCOUNT
QTY.
AMOUNT
PAID
PAID DATE
SMI - RESIDENTIAL
101-0000-20308
0
$19.50
$19.50
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $19.50 $19.50
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DOOR/WINDOW, NEW, FIRST 1
101-0000-42400
0
$60.91
$60.91
3/23/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R14137
2355
MFA
'DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DOOR/WINDOW, NEW, FIRST 1 PC.
101-0000-42600
0
$59.46
$59.46
3/23/16
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R14137
2355
MFA
Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $120.37 $120.37
TOTALS:
Description: PFEIFFER RESIDENCE / REMODEL
Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: REVISIONS REQUESTED
Applied: 8/18/2015 MFA
Approved: 9/22/2015 JJO
Parcel No: 646210025 Site Address: 49725 ANACAPA CIR LA QUINTA,CA 92253
Subdivision: Block: Lot: 1
Issued: 10/2/2015 MFA
Lot Sci Ft: 0 Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $150,000.00 Occupancy Type: Construction Type:
Expired: 7/13/2016 crw
No. Buildings: 0 No. Stories:.0 No. Unites: 0
COMPLETION DATE
Details: REM / ADDITION PER 2013 CRC CODES, 206 SQ. FT. HABITABLE SPACE AND 128 GARAGE ADDITION.
ADDITION OF NEW WINDOW IN DINING ROOM
10
r
35,�r
J Applied to Approved
FM Approved to Issued
Printed: Wednesday, March 23, 2016 12:37:00 PM 1 of 8 C
SYSTEMS
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
NOTE
MARY FASANO
10/2/2015
10/2/2015
ALL CONDITIONS MET PER JIM JOHNSON
PLAN CHECK COMMENTS
FROM CONSULTANT
RECEIVED
MARY FASANO
8/28/2015
8/31/2015
PLAN CHECK PICKED UP
STEPHANIE KHATAMI
9/3/2015
9/3/2015
plan check picked up by Gabriel Rios.
PLAN CHECK SUBMITTAL
RECEIVED
STEPHANIE KHATAMl
1/7/2016
1/7/2016
DINIDNG ROOM WINDOW REVISION
PUBLIC COUNTER VISIT
MARY FASANO
8/18/2015
8/18/2015
PUBLIC COUNTER VISIT
MARY FASANO
9/22/2015
9/22/2015
SCHOOL CERT BROUGHT IN
TELEPHONE CALL
JIM JOHNSON
9/1/2015
9/1/2015
CALLED GABRIEL TO INFORM HIM THE PLANS ARE READY FOR
CORRECTIONS
Printed: Wednesday, March 23, 2016 12:37:00 PM 1 of 8 C
SYSTEMS
Printed: Wednesday, March 23, 2016 12:37:00 PM 2 of 8
• ?1.3►L./ SYS TEti1S
FINANCIAL
CALLED GABERIAL TO INFORM_ HIM PLANS ARE READY TO
TELEPHONE CALL
JIM JOHNSON
9/22/2015
9/22/2015
ISSUE AND SCHOOL FEE LETTER IS DUE.
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
CALLED MARIONNE NOUSKAJIAN TO INFORM HIM PLANS
TELEPHONE CALL
JIM JOHNSON
CHECK #
1/13/2016
PAID BY
1/13/2016
BY
ADDITION, EA
HAVE CORRECTIONS
0
$62.36
$62.36
10/2/15
R9708
2186
CHECK
CONDITIONS
MFA
ADDITIONAL 500 SF
CONDITION
DATE
INTERIORS
DATE
DATE
101-0000-42600
0
$17.40
$17.40
10/2/15
CONTACT
2186
CHECK
MARIANNES
MFA
STATUS
REMARKS
NOTES
TYPE
ADDED
REQUIRED
SATISFIED
INTERIORS
ADDITION, FIRST 100 SF
101-0000-42400
READY TO ISSUE
JIM JOHNSON
9/22/2015
10/2/15
R9708.
2186
PENDING
MARIANNES
MFA
NEED ABESTOS REPORT BEFORE WE ISSUE
CHECKLIST
INTERIORS
READY TO ISSUE
JIM JOHNSON
1/13/2016
$171.14
$171.14
3/22/2016
COMPLETE
2186
CHECK
NEED STRUC CALCS FOR HEADER NEW WINDOW
CHECKLIST
PC
I
I
I
INTERIORS
Total Paid for ADDITION: $371.73 $371.73
CONTACTS
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP PHONE FAX EMAIL
APPLICANT '
GABRIEL RIOS
49901 CINNABAR LN
COACHELLA
CA
CONTRACTOR
OWNER/BUILDER
OWNER
LARRY & MORGAN PFEIFFER
49725 ANACAPA CIR
LA QUINTA
CA
92253
Printed: Wednesday, March 23, 2016 12:37:00 PM 2 of 8
• ?1.3►L./ SYS TEti1S
FINANCIAL
INFORMATION
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
ADDITION, EA
101-0000-42400
0
$62.36
$62.36
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
ADDITIONAL 500 SF
INTERIORS
ADDITION, EA
101-0000-42600
0
$17.40
$17.40
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
ADDITIONAL 500 SF PC
I
I
INTERIORS
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83
$120.83
10/2/15
R9708.
2186
CHECK
MARIANNES
MFA
INTERIORS
ADDITION, FIRST 100 SF
101-0000-42600
0
$171.14
$171.14
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
PC
I
I
I
INTERIORS
Total Paid for ADDITION: $371.73 $371.73
Printed: Wednesday, March 23, 2016 12:37:00 PM 2 of 8
• ?1.3►L./ SYS TEti1S
^ Permit Details PERMIT NUMBER
r
,r City of La Quinta BRES2015=03.11 - ,."
Printed: Wednesday, March 23, 2016 12:37:00 PM 3 of 8
B?SYSTENIS
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
HOURLY PLAN CHECK-
101-0000-42600
2
$140.00
$140.00
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
YES
INTERIORS
Total Paid for BLDG CITY STAFF- PER HOUR: $140.00 $140.00
BSAS SB1473 FEE
101-0000-203060
$6.00
$6.00
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
Total Paid for BUILDING STANDARDS ADMINISTRATION
$6.00 $6.00
BSA:
RESIDENTIAL, EA
101-0000-42403
0
$24.66
$24.66
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
ADDITION 1,000SF
INTERIORS
RESIDENTIAL, EA
101-0000-42600
0
$10.16
$10.16
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
ADDITION 1,000SF, PC
INTERIORS
RESIDENTIAL, FIRST .
101-0000-42403
0
$145.03
$145.03
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
1,000SF
INTERIORS
RESIDENTIAL, FIRST
101-0000-42600
0
$47.86
$47.86
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
1,000SF, PC
INTERIORS
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $227.71 $227.71
CONDENSER/COMPRES
101-0000-42402
0
$72.52
$72.52
10%2/15
R9708
2186
CHECK
MARIANNES
MFA
SOR
INTERIORS
CONDENSER/COMPRES
101-0000-42600
0
$48.34
$48.34
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
SOR PC
INTERIORS
EXHAUST HOOD
101-0000-42402
0
$12.09
$12.09
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
EXHAUST HOOD PC
101-0000-42600
0
$4.83
$4.83
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
FURNACE
101-0000-42402
0
$72.52
$72.52
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
FURNACE PC
101-0000-42600
0
$48.34
$48.34
10/2/15
R9708
2186
CHECK
MARIANNES
71
MFA
INTERIORS
Printed: Wednesday, March 23, 2016 12:37:00 PM 3 of 8
B?SYSTENIS
Printed: Wednesday, March 23, 2016 12:37:00 PM 4 of 8 0?
sysrrMs
CL
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
VENT FAN
101-0000-42402
0
$36.27
$36.27
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
VENT FAN PC
101-0000-42600
0
$14.49
$14.49
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
Total Paid for MECHANICAL: $309.40 $309.40
FIXTURE/TRAP
101-0000-42401
0
$132.99
$132.99
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
FIXTURE/TRAP PC
101-0000-42600
0
$132.99
$132.99
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
GAS SYSTEM, 5+
101-0000-42401
0
$36.26
$36.26
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
OUTLETS
INTERIORS
GAS SYSTEM, 5+
101-0000-42600
0
$24.17
$24.17
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
OUTLETS PC
INTERIORS
WATER HEATER/VENT
101-0000-42401
0
$24.18—
$24.18
10/2/15
R9708-
2186
CHECK
MARIANNES
MFA
INTERIORS
WATER HEATER/VENT
101-0000-42600
0
$14.50
$14.50
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
PC
INTERIORS
WATER SYSTEM
101-0000-42401
0
$12.09
$12.09
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INST/ALT/REP
INTERIORS
WATER SYSTEM
101-0000-42600
0
$12.09
$12.09
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INST/ALT/REP PC
INTERIORS
Total Paid for PLUMBING FEES: $389.27 $389.27
REMODEL, EA
101-0000-42400
0
$108.75
$108.75
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
ADDITIONAL 500 SF
INTERIORS
REMODEL, EA
101-0000-42600
0
$87.00
$87.00
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
ADDITIONAL 500 SF PC
INTERIORS
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$49.31
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
Printed: Wednesday, March 23, 2016 12:37:00 PM 4 of 8 0?
sysrrMs
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
COMPLETED
RESULT
REMARKS
NOTES
DATE
DATE
BY
REMODEL, FIRST 500 SF
101-0000-42600
0
$134.88
$134.88
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
PC
INSPECTION WAS OK
ROUGH PLBG
LUR
INTERIORS
10/28/2015
Total Paid for REMODEL: $379.94 $379.94
SMI - RESIDENTIAL
101-0000-203080
$19.50
$19.50
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
APPROVED
POUR THE REST OF HOME.
FOOTINGS
INTERIORS
11/12/2015
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $19.50 $19.50
DOOR/WINDOW, NEW,
101-0000-42400
0
$60.91
$60.91
3/23/16
R14137
2355
CHECK
MARIANNES
MFA
FIRST 1
ROOF NAIL
LUR
11/20/2015
11/20/2015
APPROVED
INTERIORS
DOOR/WINDOW, NEW,
0
$59.46
$59.46
3/23/16
R14137
2355
CHECK
NES
MARIA101-0000-42600
MFA
FIRST 1 PC
I NTERI
INTERIORS
Total Paid for WINDOW/SLIDING GLASS
$120.37 $120.37
DOOR/FENESTRATION:
TOTALS:
Printed: Wednesday, March 23, 2016 12:37:00 PM 5 of 8
SYS 7EM5
INSPECTIONS
SEQID
INSPECTION TYPE
INSPECTOR
SCHEDULED
COMPLETED
RESULT
REMARKS
NOTES
DATE
DATE
UNDERGROUND PLBG
LUR
10/28/2015
10/28/2015
APPROVED
KITCHEN ISLAND DRAIN NOT ON PLANS.
INSPECTION WAS OK
ROUGH PLBG
LUR
10/28/2015
10/28/2015
NOT READY
FOOTINGS
LUR
11/2/2015
11/2/2015
PARTIALLY
EVERYTHING BUT PATIO FOOTINGS. OK TO
APPROVED
POUR THE REST OF HOME.
FOOTINGS
JFU
11/12/2015
11/12/2015
PARTIALLY
(2) PAD FOOTINGS NEAR PATIO.
APPROVED
ROOF NAIL
LUR
11/20/2015
11/20/2015
APPROVED
Printed: Wednesday, March 23, 2016 12:37:00 PM 5 of 8
SYS 7EM5
FRAMING
JFU
12/29/2015 1
12/29/2015
DISAPPROVE
D
-NAIL PLATES REQUIRED WHERE
WIRING/PLUMBING IS LOCATED WITHIN 1"
OF FACE OF STUD
-FIX AND CONNECT LAV VENTS AT SOUTH
BATHROOM
-EXHAUST FAN MISSING AT LAUNDRY
-CONNECT ALL EXHAUST FANS, VENT TO
OUTSIDE.
-ADD 4020 WINDOW ON WEST WALL TO
SCOPE OF WORK AND ENERGY REPORT. PAY
ADDITIONAL WINDOW CHANGEOUT FEE.
-WINDOW VALUES DO NOT MATCH ENERGY
REPORT.
-CORRECT TOP PLATE SPLICE AT LAUNDRY
-GROUND SCREWS AT METAL PANCAKE
BOXES
-SHEAR WALL AT BEDROOM 2 MUST EXTEND
TO DOUBLE TOP PLATES, PER SHEAR WALL
NOTES .
-A-35'S MISSING AT SHEAR WALL TRANSFER
AT SOUTH WALL OF BEDROOM 1
-PROVIDE TEMPERED SIDELIGHT WINDOW
AT FRONT ENTRY DOOR
-PROVIDE DETAIL/REVISE PLAN FOR NEW
WATER HEATER CLOSET DESIGN.
-ADDITIONAL CORRECTIONS MAY APPLY.
Printed: Wednesday, March 23, 2016 12:37:00 PM 6 of 8
Cl?SYSTEti1S
WINDOW VALUES DO NOT MATCH ENERGY
APPROVED
REPORT. APPROVAL TO PROCEED AT RISK.
OKAY TO WRAP
JFU
12/29/2015
12/29/2015
W/EXCEPTIO
OWNER/BUILDER NOTIFIED THAT REVISED
N
TITLE 24 REPORT MUST BE SUBMITTED AND
WINDOWS MAY NEED TO BE CHANGED OUT.
ROUGH ELEC
JFU
12/29/2015
12/29/2015
DISAPDPROVE
SEE FRAMING INSPECTION NOTES.
ROUGH MECH
JFU
12/29/2015
12/29/2015
DISAPDPROVE
SEE FRAMING INSPECTION NOTES.
Printed: Wednesday, March 23, 2016 12:37:00 PM 6 of 8
Cl?SYSTEti1S
Printed: Wednesday, March 23, 2016 12:37:00 PM 7 of 8
IJ {i SYS Tf: h1S
ROUGH PLBG
JFU
12/29/2015
12/29/2015
DISAPPROVE
SEE FRAMING INSPECTION NOTES.
-STRAP ALL WIRING APPROPRIATELY
-REMOVE ALL ABANDONED ELECTRICAL
_
-COUNTERTOP RECEPTACLES AT KITCHEN
MUST HAVE DEDICATED CIRCUIT WITH NO
FRAMING
JFU
1/7/2016
1/7/2016
DISAPPROVE
OTHER RECEPTACLES -
D
-SEDIMENT TRAPS REQUIRED AT FAU'S
-SUBMIT REVISED PLANS AND ENERGY
REPORT FOR REVIEW
-SUBMIT SPECS/DESIGN FOR NEW WATER
HEATER ENCLOSURE
ROUGH ELEC
JFU
1/7/2016
1/7/2016
DISAPDPROVE
SEE FRAMING INSPECTION NOTES.
ROUGH MECH
JFU
1/7/2016
1/7/2016
DISAPDPROVE
SEE FRAMING INSPECTION NOTES.
ROUGH PLBG
JFU
1/7/2016
1/7/2016
DISAPPROVE
SEE FRAMING INSPECTION NOTES.
FRAMING
JFU
1/8/2016
1/8/2016
APPROVED
ROUGH ELEC
JFU
1/8/2016
1/8/2016
APPROVED
ROUGH MECH
JFU
1/8/2016
1/8/2016
APPROVED
ROUGH PLBG
JFU
1/8/2016
1/8/2016
APPROVED
PARTIALLY
DOES NOT INCLUDE EAST EXTERIOR WALL
INSULATION
JFU
1/11/2016
1/11/2016
OR GOLF CART GARAGE -LID. OKAY TO
APPROVED
DRYWALL ALL OTHER AREAS.
INSULATION
JFU
1/12/2016
1/13/2016
APPROVED
COMPLETE APPROVAL.
LATH
LUR
1/15/2016
1/15/2016
APPROVED
DRYWALL NAIL
LUR
1/15/2016
1/15/2016
APPROVED
PARENT PROJECTS
Printed: Wednesday, March 23, 2016 12:37:00 PM 7 of 8
IJ {i SYS Tf: h1S
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
RETURNED
STATUS
REMARKS
NOTES
Attachment Type
CREATED
DATE
DESCRIPTION
PATHNAME
SUBDIR
NON-STRUCTURAL -
BUILDING
8/18/2015
9/1/2015
9/1/2015
REVISIONS REQUIRED
0
2 WK
BUCKET
CIR..docx
CIR..docx
DOC
STRUCTURAL - 2 WK
YOUNG
8/18/2015
9/1/2015
8/20/2015
READY FOR APPROVAL
ENGINEERING
0311.pdf
DOC
3/22/2016
JIM JOHNSON
2ND BLDG NS (2
JIM JOHNSON.
9/18/2015
10/2/2015
9/22/2015
APPROVED
0311.pdf
WK)
1ST REVIEW -
NEW CITY
1ST BLDG NS (1 WK)
JIM JOHNSON
1/7/2016
1/14/2016
1/13/2016
REVISIONS REQUIRED
REVISION 1
REVISION - ADD WINDOW AT DINING ROOM.
Printed: Wednesday, March 23, 2016 12:37:00 PM 8 of 8 C9?
SYSTEMS
BOND INFORMATION
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
9/10/2015
JIM JOHNSON
49-725 ANACAPA
49-725 ANACAPA
0
CIR..docx
CIR..docx
DOC
9/12/2015
JIM JOHNSON
SCHOOL FEES BRES2015-
SCHOOL FEES BRES2015-
0
0311.pdf
0311.pdf
DOC
3/22/2016
JIM JOHNSON
ADDENDUM BRES2015-
ADDENDUM BRES2015-
0
0311.pdf
0311.pdf
1ST REVIEW -
NEW CITY
DOC
8/20/2015
KATHRYN SAMUELS
STRUCTURAL
TRANSMITTAL'BRES
0'
TRANSMITTAL
2015-0311(lst).pdf
DOC
11/2/2015
LUIS URIBE
BRES2015-0311- EPDXY
BRES2015-0311- EPDXY
0
REPORT.pdf
REPORT.pdf
HOA APPROVAL FOR
HOA APPROVAL FOR
DOC
9/3/2015
STEPHANIE KHATAMI
METAL WATER CLOSET
METAL WATER CLOSET
0
09-02-15.pdf
09-02-15.pdf
2ND SUBMITTAL CHECK
2ND SUBMITTAL CHECK
DOC
9/18/2015
STEPHANIE KHATAMI
LIST AND COMMENTS
LIST AND COMMENTS
0
ANACAPA.pdf
ANACAPA.pdf
Printed: Wednesday, March 23, 2016 12:37:00 PM 8 of 8 C9?
SYSTEMS
Bin#
C(ty of La Qulnta
Building & Safety Division
. "78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
d3 (� Building Permit Application and Tracking Sheet
Permit 4#
_
RS2
Project Address:C s�
Owner's Name:
A. P. Number:
Address: % g r✓ �/%Q% A, �Jr.
Legal Description:
City, ST, Zip: /4
Contractor: . ✓
Telephhone: p � lg�1 7am....::
Address:
Project Description:/ j f j/J// A)
City, ST, Zip:
-�O /��� yd rl 7(le,
h
T Pne•
ele o
6
State Lic. # :
City Lic. #;
Arch., Engr., Designer:
Address:
City, ST, Zip:
..
Occupancy:
aneYTelePhone: CtructionTYPe:
r DemooStatoLic.# ProJecttYPecir 1eone • New Addn Alter
Repairai
Name of Contact Person: IiyinV u,0IA�/'4)1Sq.Ft.:
# Stores:
# Units:
Z �........
Telephone # of Contact Person: C% 71 Z
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Rec'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Cafes.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance
Title 24 Cates.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2" Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IIY ROUSE:-
Review, ready for correctionsrassue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees,
Total Permit Pees
DATE: 1/13/2016
COMMUNITY DEVELOPMENT DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
(760) 777-7125 FAX (760) 777-7011
RESIDENTIAL PLAN CHECK CORRECTION LIST (os)
STATUS: FIRST REVIEW
PLAN CHECKED BY: JIM JOHNSON
TELEPHONE NUMBER: (760) 777-7130
ADDRESS: 49-725 ANACAPA CIR
DESCRIPTION: REM / ADDITION
APPLICANT: PFEIFFER
PLAN CHECK #: BRES2015-0311
This submittal has been checked for compliance with the 2013 California Residential, Mechanical, Electrical,
Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code.
APPLICANT:
The following items are being returned to you for
correction:
3 SETS OF PLANS
2 SETS TITLE' -24
THIS CORRECTION LIST
DO NOT accept any resubmittal unless ALL of the
BUILDING DEPARTMENT STAFF:
following items are included:
REDLINED SETS
2 NEW REVISED SETS
ASSESSORS SET
2 SETS TITLE -24
2 SETS STRUC CALCS
THIS CORRECTION LIST / RESPONSES
INSTRUCTIONS TO APPLICANT:
1) Provide a written response to each comment on the following pages, noting specifically where the correction
can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not
acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses
such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check.
2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or
Calculations as necessary.
3) Return all red -marked Plans and/or Calculations with your resubmittal.
4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number
and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and
Professions Code Section 5536. Resubmittals will not be accepted with signatures missing.
5) Return this list, your written responses, and all documents listed above with your resubmittal. '
Residential Plan Check Correction List Page 1 of 2
,4
SECTION I - STRUCTURAL
1) See separate structural correction list, attached. PROVIDE NEW HEADER SIZE BY ENGINEER OF
RECORD.
Important note to Engineer of Record:
If these corrections require revisions to structural calculations, in response to these corrections., do NOT simply
submit two copies of a few supplemental calculations.
For resubmittal, include:
SECTION K - MISCELLANEOUS COMMENTS
1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise
Plans as necessary and provide written response, noting where correction can be found.
END CORRECTION LIST
As further information is provided and reviewed, additional corrections may be required.
Residential Plan Check Correction List Page 2 of 2
Tjhf 4 44"
COMMUNITY DEVELOPMENT DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
(760) 777-7125 FAX (.760) 777-7011
RESIDENTIAL PLAN CHECK CORRECTION LIST (os)
DATE: 1/13/2016
STATUS: FIRST REVIEW
PLAN CHECKED BY: JIM JOHNSON
TELEPHONE NUMBER: (760) 777-7130
ADDRESS: 49-725 ANACAPA CIR
DESCRIPTION: REM / ADDITION
APPLICANT: PFEIFFER
PLAN CHECK #: BRES2015-0311
This submittal has been checked for compliance with the 2013 California Residential, Mechanical, Electrical,
Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code.
APPLICANT:
The following items are being returned to you for
correction:
3 SETS OF PLANS
2 SETS TITLE -24
THIS CORRECTION LIST
DO NOT accept any resubmittal unless ALL of the
BUILDING DEPARTMENT STAFF:
following items are included:
REDLINED SETS
2 NEW REVISED SETS
ASSESSORS SET
2 SETS TITLE -24
2 SETS STRUC CALCS
THIS CORRECTION LIST / RESPONSES
INSTRUCTIONS TO APPLICANT:
1) Provide a written response to each comment on the following pages, noting specifically where the correction
can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not
acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses
such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check.
2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or
Calculations as necessary.
3) Return all red -marked Plans and/or Calculations with your resubmittal.
4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number
and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and
Professions Code Section 5536. Resubmittals will not be accepted with signatures missing.
5) Return this list, your written responses, and all documents listed above with your resubmittal.
. Residential Plan Check Correction List Pagel of 2
SECTION I - STRUCTURAL
1) See -separate structural correction list, attached. PROVIDE NEW HEADER SIZE BY ENGINEER OF
RECORD.
Important note to Engineer of Record:
If these corrections require revisions to structural calculations, in response to these corrections, do NOT simply
submit two copies of a few supplemental calculations.
For resubmittal, include:
SECTION K - MISCELLANEOUS COMMENTS
1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise
Plans as necessary and provide written response, noting where correction can be found.
END CORRECTION LIST
As further information is provided and reviewed, additional corrections may be required.
Residential Plan Check Correction List
Page 2 of 2
BUILDING ENERGY ANALYSIS REPORT
R�
PROJECT:
Pfeiffer Residence
49-725 Anacapa Circle
La Quinta, CA
Project Designer:
OF
3L,,: - )!NG & SAFETY DEPT.
i - PROVE ID
cfl CON TRUCTION
Report Prepared by:. �2,1.92
Joan D. Hacker- -
Insu-form, Inc.
72875 Fred Waring Drive, Suite C
Palm Desert, Ca 92260
760-345-1352
Job Number: 110),A U
JAN 0 7 2016
ClTy Or L' QUINTA
Date: COEVE
MMUNITY DLOPMENT DEPARTMENT
1/5/2016
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
I TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF -1 R -PRF -01-E Certificate of Compliance 3
Form RMS -1 Residential Measures Summary 11
Form MF -1 R Mandatory Measures Summary 12
HVAC System Heating and Cooling Loads Summary 16
EnergjyPro 6.7 bjy EnetgySoft Job Number: ID: User Number: 2655
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation DateMme: 14:23, Tue, Jan 05, 2016
Calculation Description: Title 24 Analysis Input File Name: Pfeiffer Exist Addition.xml
CF1 R -PRF -01
Page 1 of 8
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name Single Fam Detached
04
05
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
'Project Location 49-725 Anacapa Circle
Compliance Margin
Percent,lmprovement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 0
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1.
14
Total Cond. Floor Area (ft2) 2308
15
Number of Zones 2
16
Slab Area (ft2) 2308
17
Number of Stories 1
18
Addition Cond. Floor Area 206
19
Natural Gas Available Yes
20
Addition Slab Area (ft2) 206
21
Glaiing Percentage (°k) 11.3%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
03 This building Incorporates one or more Special Features shown Below
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2016-01-05 14:24:42
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent,lmprovement
Space Heating
8.59
8.18
0.41
4.8%
Space Cooling
156.44
157.53
-1.09
-0.7%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
14.54
12.58
1.96
13.5%
Photovoltaic Offset
----
0.00
0.00
--
Compliance Energy Total
179.57
178.29
1.28
0.7%
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2016-01-05 14:24:42
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:23, Tue, Jan 05, 2016
Input File Name: Pfeiffer Exist Addition.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cathedral Ceiling
• Window overhangs and/or fins
HERS FEATURE SUMMARY
CF1 R -PRF -01
Page 2 of 8
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• — None —
Cooling System Verifications:
— None —
HVAC Distribution System Verifications:
• — None —
Domestic Hot Water System Verifications:
• — None —
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating MarginPercent Improvement
Total Energy (kTDV/f2-yr)' 225.05 223.77 1.28 0.6%
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Single Fam Detached
2308
1
6
2
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Existing Living
Conditioned
Living Zone1
2102
9
DHW Sys 1
Addition
Conditioned
Living Zonal
206
9
DHW Sys 1
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2016-01-05 14:24:42
CF1 R -PRF -01
Page 3 of 8
ATTIC
19
10
atus
Verified
Existing
Condition
sting
No
sting
No
sting
No
sting
No
-red
N/A
ew
N/A
ew
N/A
ew
N/A
ew
N/A
ew
N/A
ATTIC
12
13
itatus
Verified
Existing
Condiflon
dtered
N/A
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant
Barrier
Cool Roof
Statu
s
Verified Existing
Condition
Attic Existing Living
Attic RoofExisting Living
Ventilated
0
0.1
0.85
No
No
Alt re
No
Attic Addition
Attic RoofAddition
Ventilated
0
0.1
0.85
No
No
New
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2016-01-05 14:24:42
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 14:23, Tue, Jan 05, 2016
Calculation Description: Title 24 Analysis
Input File Name: Pfeiffer Exist Addition.xml
CF1 R -PRF -01
Page 4 of 8
WINDOWS
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Height (ft)
Multiplle
r
Area (W)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
Window
Front Wall (Front -0)
4.0
2.0
1.25
10.0
0.50
0.33
Insect Screen (default)
Altered
N/A
Window 2
Front Wall (Front -0)
1.4
6.0
0.952
8.0
0.50
0.33
Insect Screen (default)
Altered
N/A
Window 3
Left Wall (Left -90)
2.0
2.0
1
4.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 4
Left Wall (Left -90)
2.5
4.0
1
10.0
0.50
0.33
Insect Screen (default)
Altered
N/A
Window 5
Left Wall (Left -90)
2.5
4.0
1
10.0
0.50
0.33
Insect Screen (default)
Altered
WA
Window 6
Left Wall (Left -90)
5.0
3.0
1
15.0
0.50
0.33
Insect Screen (default)
Altered
N/A
Window 7
Left Wall (Left -90)
3.0
6.0
0.25
4.5
0.50
0.33
Insect Screen (default)
Altered
N/A
Window 8
Rear Wall (Back -180)
8.0
6.8
0.982
53.4
0.50
0.33
Insect Screen (default)
New
N/A
Window 9
Rear Wall (Back -180)
16.0
8.0
1
128.0
0.50
0.33
Insect Screen (default)
Altered
N/A
Window 10
Right Wall (Right -270)
6.0
2.5
1
15.0
0.50
0.33
Insect Screen (default)
New
N/A
Skylight
Roof (Front -0)
----
I ---
1
4.0
0.71 1
0.73
None
Existing
No
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12 13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up Dist R
Bot Up
Window
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 2
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 3
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 4
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 5
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 6
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 7
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 8
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 9
2
0.1
2
2
0
4
0
0.1
0
4
0 0.1
0
Window 10
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2016-01-05 14:24:42
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Datefrime: 14:23, Tue, Jan 05, 2016
Calculation Description: Title 24 Analysis
Input File Name: Pfeiffer Exist Addition.xml
CF1 R -PRF -01
Page 5 of 8
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
09
Name
Zone
Total Cavity
Winter Design
Edge Insul. R -value
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
620
None
0.8
No
Existing
No
- Cavity/ Frame: no insul. /2x4 Top Chrd
Addition
206
2
None
0.8
No
- Roof Deck: Wood Siding/sheathing/decking
No
2x4 Top Chord of Roof Truss @ 24
- Above Deck Insulation: RI I Sheathing
Attic RoofExisting Living
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.079
- Roofing: Light Roof (Asphalt Shingle)
- Inside Finish: Gypsum Board
- Cavity/Frame: R-11 /2x4
- Exterior Finish: Wood
Default Wall 1978 to 1991
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 11
0.103
Siding/sheathing/decking
Ceilings (below
- Inside Finish: Gypsum Board
Roof Rigid
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
none
0.472
- Cavity/Frame: no insul. /2x4
- Inside Finish: Gypsum Board
- Cavity/Frame: no insul. /2x4
- Roof Deck: Wood Siding/sheathing/decking
- Above Deck Insulation: R11 Sheathing
Roof Rigidl
Cathedral Ceilings
Wood Framed Ceiling
2x4 @ 16 in. O.C.
none
0.076
- Roofing: Light Roof (Asphalt Shingle)
- Cavity/Frame: no insul. /2x4 Top Chrd
- Roof Deck: Wood Siding/sheathing/decking
2x4 Top Chord of Roof Truss @ 24
- Above Deck Insulation: Rio Sheathing
Attic RoofAddition
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.086
- Roofing: Light Roof (Asphalt Shingle)
- Inside Finish: Gypsum Board
- Cavity/Frame: R -13/2x4
• Exterior Finish: Wood
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ftz)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Covered Slab
Existing Living
2102
620
None
0.8
No
Existing
No
Slab -on -Grade
Addition
206
2
None
0.8
No
New
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required ---
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2016-01-05 14:24:42
CH R -PRF -01
Page 6 of 8
07 08
'ank Exterior Standby Loss
ulation R -value (Fraction)
0 0
06
07
08
it
on
Status
Verified Existing
Condition
al
Altered
No
07 08
'ank Exterior Standby Loss
ulation R -value (Fraction)
0 0
HVAC - HEATING SYSTEMS
06
07
ulation with
al Control
Recirculation with
Sensor Control
n/a
n/a
HVAC - HEATING SYSTEMS
08
09
Status
Verified Existing
Condition
Existing
No
HVAC - HEATING SYSTEMS
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
78 AFUE
Registration Number: Registration Date/Time: ,
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2016-01-05 14:24:42
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:23, Tue, Jan 05, 2016
Input File Name: Pfeiffer Exist Addition.xml
CF7 R -PRF -01
Page 7 of 8
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
07
08
Efflclency
10
Multi -speed
Verified Duct Location
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
DuctlessSplitAirCond - Ductless
10
12
No
No
N/A
Location
mini -split and multi -split heat A/C
Status
Condition
Verification
Air Distribution
Ducts located in attic
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Duct Leakage
Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Insulation
Supply Duct
Return Duct
--
-- --
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
8.0
Attic
Attic
None
Existing
No
N/A
System 1
specified)
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05 06
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1 -hers -dist
N/A
I--
--
-- --
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAO CFM IAQ Fan Type IAO Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
Registration Number:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2016-01-05 14:24:42
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 14:23, Tue, Jan 05, 2016
Calculation Description: Title 24 Analysis
Input File Name: Pfeiffer Exist Addition.xml
CF1 R -PRF -01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Joan D. Hacker
Company:
Signature Date:
Insu-form, Inc.
1/5/2016
Address:
CEA/HERS Certification Identification (If applicable):
72875 Fred Waring Drive, Suite C
City/State ip:
Palm Desert, Ca 92260
Phone:
760-345-1352
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit applicati n.
Responsible Designer Name:
Responsible Designer Signature:
Gabriel Rios
Company:
Date Signed:
Rios Designs
01/05/2016
Address:
License:
49-901 Cinnabar Lane
N/A
City/State/tip:
Phone:
Coachella, CA 92236
(760) 485-7431
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2016-01-05 14:24:42
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Pfeiffer Residence
Building Type
m Single Family 0 Addition Alone
❑ Multi Family 10 Existing+ Addition/Alteration
Date
1/5/2016
Project Address
49-725 Anacapa Circle La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,308
Addition
206
# of Units
1
INSULATION
Construction Type
Cavity
Area
(ft) Special Features Status
Slab Unheated Slab -on -Grade - no insulation
2,102 Perim = 620'
Existing
Wall Wood Framed R11
4,493
Existing
Roof Wood Framed Attic - no insulation
2,098 Rigid=R-11.0
Altered
Wall Wood Framed R 13
61
New
Roof Wood Framed - no insulation
206 Rigid=R-14.0
New
Slab Unheated Slab -on -Grade - no insulation
206 Perim = 2'
New
FENESTRATION I Total Area: 262 Glazing Percentage: 11.3
Orientation Area(ft) U -Fac SHGC Overhang Sidefins
New/Altered Average U -Factor. 0.50
Exterior Shades Status
Front (N) 18.0 0.500
0.33 2.0
none
Bug Screen Altered
Left (E) 4.0 0.710
0.73 2.0
none
Bug Screen Existing
Left (E) 39.5 0.500
0.33 2.0
none
Bug Screen Altered
Rear (S) 53.4 0.500
0.33 2.0
none
Bug Screen New
Rear (S) 128.0 0.500
0.33 2.0
4.00/4.00
Bug Screen Altered
Right (W 15.0 0.500
0.33 2.0
none
Bug Screen New
Skylight 4.0 0.710
0.73 none
none
None Existing
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling
Min. Eff
Thermostat Status
2 Central Furnace 78% AFUE
Split Air Conditioner 12.0 SEER
Setback Existing
HVAC DISTRIBUTION
Location Heating
Cooling
Duct Location
Duct
R -Value Status
Living Zone Ductless/ with Fan
Ductless
n/a
n/a Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
2 Small Storage Gas 50
0.65
Standard
Altered
EnenqvPro6.7 by Ener Soft User Number: 2655
RunCode: 2016-01-05714:31:06
ID: Pae 11 of 16
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
comnliance annroach used. Exceptions may aDDly. Review the respective code section for more information.
Building Envelope Measures:
§110.6(a)l:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets therequirements of 10-111 a .
§110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of §110.8(1) when the
installation of a cool roof is specified on the CF1R.
§110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF1R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class 11 vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§150.0(g)1:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class lI
§150.0(8)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§150.00):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets therequirements of § 110.8
§150.0(q):
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)1B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible operable, and tight -fitting damper or a combustion -air control device.
§150.0(e)IC:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building,are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 1103(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§150.0(1):
Heating systems are equipped with thermostats that meet the setback requirements of §110.2(c).
§150.00)IA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150.00)1B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R -I6 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§150.06)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§150.06)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation removaland replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§150.06)2C:
Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating
stems or hot waters stems with pressure > 15 psig shall meet therequirements in TABLE 120.3-A.
§150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of §110.3(c)5.
§150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing enc approved by the Executive Director.
Ducts and Fans Measures:
All air distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§150.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/< inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§150.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13:
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of 2! 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic
testing,in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§150.0(o):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
settin • a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines or built-up connections for future solar heating.
§I 10.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9.
§150.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B as applicable.
§150.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of 150.0
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§150.0(k)IC:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§150.0(k)ID:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 15 0. 0
§150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §I50.0(k).
§150.0(k)2F:
Lighting controls comply with applicable requirements of §110.9.
An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§150.0(k)2G:
according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it
§150.0(k)2H:
functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements
of 130.5 • and all other requirements in 150.0 2.
§150.0(k)21:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to 110.9, and complies with all other applicable requirements in § 150.0 2.
§150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy,or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§150.0(k)9B:
following requirements:
i. Shall comply with § 150.0(k)9A; or
ii. Shall comply with the applicable requirements in 110.9 130.0 § 130.2 130.4 140.7 and 141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in 110.9 130.0 130.2 130.4 140.7 and 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9 130.0 § 130.2 § 130.4 § 140.7 and § 141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to §130.0(c).
§ 150.0(k)l 1:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in 110.9, 130.0 130.1 130.4 140.6 and 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)12B:
i• Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§110.10(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with therequirements of § 110.10 through 110.10 e .
110.10(a)2:
Low-rise multi -family buildings shall comply with therequirements of § 110.10(b) through 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§110.10(b)l:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone measured in the vertical plane.
§110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
stem.
§110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§110.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location and permanently marked as "For Future Solar Electric'.
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Pfeiffer Residence
Date
1/5/2016
System Name
Living Zone
Floor Area
2,308
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL COOLING PEAK
CFM Sensible
Total Room Loads 2,557 38,686
Return Vented Lighting 0
Return Air Ducts 0
Return Fan 0
Ventilation 0 0
Supply Fan 0
Supply Air Ducts 0
TOTAL SYSTEM LOAD 38,6861
COIL HTG.
Latent CFM
2,160 1,864
0 0
2,160
PEAK
Heating System
Sensible
Output per System 70,000
59,052
Total Output Btuh 140,000
Output Btuh/s ft 60.7
0
Cooling System
0
Output per System 58,000
0
Total Output Btuh 116,000
0
Total Output Tons 9.7
0
Total Output Btuh/s ft 50.3
Total Output s ftfTon 238.8
F 59,052
Air System
CFM per System
2,210
HVAC EQUIPMENT SELECTION
Airflow cfm
4,420
Existing 66,869
40,888
140,000
Airflow cfm/s
1.92
Airflow cfm/Ton
457.2
Outside Air %
0-0%
Total Adjusted System Output 66,869
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
40,888
Aug 3 PM
140,000
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Air -4 r-
0 cfm
70 OF
70 OF 100 OF 100 OF
U-11—TuOutside
M -----
Heating Coil Supply Fan
4,420 cfm
100 OF
ROOM [7k
70 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
0 cfm
78 / 68 OF
78/68°F 64/63°F 64/63°F
..q O
Cooling Coil Supply Fan 64 / 63 OF
4,420 cfm
59.2% ROOM
78 / 68 OF
EnergyPro 6.7 by EnergySoft
User Number.' 2655 RunCode: 2016-01-05T14:31:06 /D:
Page 16 of 16
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
,T4ht 44aw
COMMUNITY DEVELOPMENTDEPARTQ
BUILICIA6PERMIT 11
Application Number: BRES2015-0311
Property Address: 49725 ANACAPA CIR
APN: 646210025
Application Description: PFEIFFER RESIDENCE / REMODEL
Property Zoning:
Application Valuation: $150,000.00
Applicant:
GABRIEL RIOS
49901 CINNABAR LN
COACHELLA, CA
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: License No.:
Date: Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon; and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
w'Ain one year of completion, the owner -builder will have the burden of proving that
e did not build or improve for the purpose of sale.).
I, as owner of the property, am exclusively contracting with licensed contractors
t construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. forth' reason
Date: • 0 J Owner:
CONSTRUCTI L DING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Add
(c"i 02 2015
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT DEF
11111111111111111111
8
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760)777-7153
& MORGAN PFEIFFER
ANACAPA CIR
NTA, CA 92253
Contractor:
OWNER/BUILDER
Llc. No.:
Date: 10/2/2015
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date:
Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application. .
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state -that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and 2 y au orize represents �Oes of this city to enter upon the
above -mention o rty i cti ry�py s S.
Date: Signature (A(pppliccaant o Aje�
/d 14 -/,,92
DESCRIPTION
FINANCIAL INFORMATION
ACCOUNT
QTY AMOUNT
PAID
PAID DATE
ADDTdiDili; EAADD1 W NAL 500 SF
101-0000-42400
0
$62.36
$62.36
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$17.40
$17.40
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83
$120.83
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$171.14
$171.14
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
Total Paid for ADDITION: $371.73 $371.73
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
HOURLY PLAN CHECK - YES
101-0000-42600
2
$140.00
$140.00
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
Total Paid for BLDG CITY STAFF - PER HOUR: $140.00 $140.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$6.00
$6.00
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $6.00 $6.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, EA ADDITION 1,000SF
101-0000-42403
0
$24.66
$24.66
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, EA ADDITION 1,000SF, PC
101-0000-42600
0
$10.16
$10.16
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$145.03
$145.03
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT'
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, FIRST 1,000SF, PC-
101-0000-42600
0
$47.86
$47.86
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $227.71 $227.71
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
CONDENSER/COMPRESSOR
101-0000-42402
0
$72.52
$72.52
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
CONDENSER/COMPRESSOR PC
101-0000-42600
0
$48.34
$48.34
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
EXHAUST HOOD
101-0000-42402
0
$12.09
$12.09
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
EXHAUST HOOD PC
101-0000-42600
0
$4.83
$4.83
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FURNACE
101-0000-42402
0
$72.52
$72.52
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
.PAID
PAID DATE
FURNACE PC
101-0000-42600
0
$48.34
$48.34
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
VENT FAN
101-0000-42402
0
$36.27
$36.27
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT.
QTY
AMOUNT
PAID
PAID DATE
VENT FAN PC
101-0000-42600
0
$14.49
$14.49
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
Total Paid for MECHANICAL: $309.40 $309.40
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FIXTURE/TRAP
101-0000-42401
0
$132.99
$132.99
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
I QTY
AMOUNT
PAID
PAID DATE
FIXTURE/TRAP PC
101-0000-42600
0
$132.99
$132.99
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MAPAANNES INTERIORS _;
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
GAS SYSTEM, S+ OUTLETS
101-0000-42401
0
$36.26
$36:26
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
GAS SYSTEM, S+ OUTLETS PC
101-0000-42600
0
$24.17
$24.17
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WATER HEATER/VENT
101-0000-42401
0
$24.18
$24.18
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY'
AMOUNT
PAID
PAID DATE
WATER HEATER/VENT PC
101-0000-42600
0
$14.50
$14.50
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$12.09
$12.09
10/2/15
PAID BY
METHOD
RECEIPT # -
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$12.09
$12.09
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS '
CHECK
R9708
2186
MFA
Total Paid for PLUMBING FEES: $389.27 $389.27
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL,.EA ADDITIONAL 500 SF
101-0000-42400
0
$108.75
$108.75
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$87.00
$87.00
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$49.31
10/2/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
DESCRIPTION
ACCOUNT -
QTY
AMOUNT
PAID •
PAID DATE
REMODEL, FIRST 500 SF PC
101-0000-42600
0
$134.88
$134.88
10/2/15
PAID BY
METHOD :
RECEIPT #
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
Total Paid for REMODEL: $379.94 $379.94
DESCRIPTION '
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
SMI - RESIDENTIAL
101-0000-20308
0
.$19.50
$19.50.
10/2/15
PAID BY
METHOD
RECEIPT #:
CHECK #
CLTD BY
MARIANNES INTERIORS
CHECK
R9708
2186
MFA
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $19.50 $19.50
TOTALS::4$1,843.55
Description: PFEIFFER RESIDENCE / REMODEL
Type: BUILDING, RESIDENTIAL
Subtype: REMODEL Status: ISSUED
Applied: 8/18/2015 MFA
Approved: 9/22/2015 JJO
Parcel No: 646210025 Site Address: 49725 ANACAPA CIR LA QUINTA,CA 92253
Subdivision:
Block: Lot: 1
Issued: 10/2/2015 MFA
Lot Sq Ft: 0
Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $150,000.00
Occupancy Type: Construction Type:
Expired: 3/30/2016 MFA
No. Buildings: 0
No. Stories: 0 No. Unites: 0
MARY FASANO
Details: REM / ADDITION PER 2013 CRC CODES, 206 SQ. FT. HABITABLE SPACE AND 128 GARAGE ADDITION.
Applied to Approved
Approved to Issued
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
NOTE
MARY FASANO
10/2/2015
10/2/2015
ALL CONDITIONS MET PER JIM JOHNSON
PLAN CHECK COMMENTS
FROM CONSULTANT
RECEIVED
MARY FASANO
8/28/2015
8/31/2015
PLAN CHECK PICKED UP
STEPHANIE KHATAMI
9/3/2015
9/3/2015
plan check picked up by Gabriel Rios.
PUBLIC COUNTER VISIT
MARY FASANO
8/18/2015
8/18/2015
PUBLIC COUNTER VISIT
MARY FASANO
9/22/2015
9/22/2015
SCHOOL CERT BROUGHT IN
TELEPHONE CALL
JIM JOHNSON
9/1/2015
9/1/2015
CALLED GABRIEL TO INFORM HIM THE PLANS ARE READY FOR
CORRECTIONS
TELEPHONE CALL
JIM JOHNSON
9/22/2015
9/22/2015
CALLED GABERIAL TO INFORM HIM PLANS ARE READY TO
ISSUE AND SCHOOL FEE LETTER IS DUE.
CONDITIONS
Printed: Friday, October 02, 2015 10:03:13 AM 1 of 5
SYSTEMS
CONDITION
TYPE .
'CONTACT.
DATE
ADDED ..
DATE.
REQUIRED
DATE
SATISFIED
STATUS
REMARKS
NOTES
READY TO ISSUE
CHECKLIST
JIM JOHNSON
9/22/2015
INFORMATION
DESCRIPTION
PENDING
QTY
NEED ABESTOS REPORT BEFORE WE ISSUE
PAID .:.
CONTACTS
NAME ADDRESSI CITY STATE ZIP . PHONE FAX EMAIL
NAME TYPE
APPLICANT
GABRIEL RIOS 49901 CINNABAR LN COACHELLA
CA
CONTRACTOR
OWNER/BUILDER
OWNER
LARRY & MORGAN PFEIFFER 49725 ANACAPA CIR LA QUINTA
CA 92253
Printed: Friday, October 02, 2015 10:03:13 AM 2 of 5
SYSTEMS
FINANCIAL
INFORMATION
DESCRIPTION
ACCOUNT:
QTY
AMOUNT
PAID .:.
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD ..
BY
ADDITION, EA
101-0000-42400
0
$62.36
$62.36
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
ADDITIONAL 500 SF
INTERIORS
ADDITION, EA
101-0000-42600
0
$17.40
$17.40
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
ADDITIONAL 500 SF PC
INTERIORS
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83
$120.83
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
ADDITION, FIRST 100 SF
101-0000-42600
0
$171.14
$171.14
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
PC
I
I
I INTERIORS
Total Paid for ADDITION: $371.73 $371.73
HOURLY PLAN CHECK-
101-0000-42600
2
$140.00
$140.00
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
YES
INTERIORS
Total Paid for BLDG CITY STAFF - PER HOUR: $140.00 $140.00
BSAS SB1473 FEE
101-0000-20306
70
$6.00
$6.00
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
Total Paid for BUILDING STANDARDS ADMINISTRATION $6.00 $6.00
BSA:
RESIDENTIAL, EA
101-0000-42403
0
$24.66
$24.66
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
ADDITION 1,000SF
INTERIORS
Printed: Friday, October 02, 2015 10:03:13 AM 2 of 5
SYSTEMS
Permit Details PERMIT NUMBER T .
BRES�2015'43'
City of La Quinta
Printed: Friday, October 02, 2015 10:03:13 AM 3 of 5
SY57FM5
TACCOUNT
CLTD
DESCRIPTIONT
CITY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
RESIDENTIAL, EA
101-0000-42600
0
$10.16
$10.16
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
ADDITION 1,000SF, PC
INTERIORS
RESIDENTIAL, FIRST
101-0000-42403
0
$145.03
$145.03
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
1,000SF
INTERIORS
RESIDENTIAL, FIRST
101-0000-426000
$47.86
1
$47.86
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
1,000SF, PC
1
1
1
INTERIORS
Total Paid for ELECTRICAL --NEW CONSTRUCTION: $227.71 $227.71
CONDENSER/COMPRES
101-0000-42402
0
$72.52
$72.52
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
SOR
INTERIORS
CONDENSER/COMPRES
101-0000-42600
0
$48.34
$48.34
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
SOR PC
INTERIORS
EXHAUST HOOD
101-0000-42402
0
$12.09
$12.09
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
EXHAUST HOOD PC
101-0000-42600
0
$4.83
$4.83
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
FURNACE
101-0000-42402
0
$72.52
$72.52
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
FURNACE PC
101-0000-42600
0
$48.34
$48.34
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
VENT FAN
101-0000-42402
0
$36.27
$36.27
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
VENT FAN PC
101-0000-42600
0
$14.49
$14.49
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
Total Paid for MECHANICAL: $309.40 $309.40
FIXTURE/TRAP
101-0000-42401
0
$132.99
$132.99
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
FIXTURE/TRAP PC
101-0000-42600
0
$132.99
$132.99
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
GAS SYSTEM, 5+
101-0000-42401
0
$36.26
$36.26
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
OUTLETS
INTERIORS
Printed: Friday, October 02, 2015 10:03:13 AM 3 of 5
SY57FM5
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED
DATE DATE
RESULT, REMARKS NOTES
FINAL*" BLD
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
GAS SYSTEM, 5+
101-0000-42600
0
$24.17
$24.17
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
OUTLETS PC
INTERIORS
WATER HEATER/VENT
101-0000-42401
0
$24.18
$24.18
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
WATER HEATER/VENT
101-0000-42600
0
$14.50
$14.50
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
PC
INTERIORS
WATER SYSTEM
101-0000-42401
0
$12.09
$12.09
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INST/ALT/REP
INTERIORS
WATER SYSTEM
101-0000-42600
0
$12.09
$12.09
10/2/15
R9708
2186
CHECK .
MARIANNES
MFA
INST/ALT/REP PC
INTERIORS
Total Paid for PLUMBING FEES: $389.27 $389.27
REMODEL, EA
101-0000-42400
0
$108.75
$108.75
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
ADDITIONAL 500 SF
INTERIORS
REMODEL, EA
101-0000-42600
0
$87.00
$87.00
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
ADDITIONAL 500 SF PC
INTERIORS
REMODEL, FIRST 100 SF
101-0000-42400
0
$49.31
$49.31
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
REMODEL, FIRST 500 SF
101-0000-426000
$134.88
$134.88
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
PC
INTERIORS
Total Paid for REMODEL: $379.94 $379.94
SMI - RESIDENTIAL
101-0000-20308
0
$19.50
$19.50
10/2/15
R9708
2186
CHECK
MARIANNES
MFA
INTERIORS
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $19.50 $19.50
TOTALS::4
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED
DATE DATE
RESULT, REMARKS NOTES
FINAL*" BLD
Printed: Friday, October 02, 2015 10:03:13 AM 4 of 5 Ca
SYST;MS
BOND INFORMATION
PROJECTS
PARENT
CREATED ::..
._: OWNER ;..
ATTACHMENTS
DESCRIPTION
PATHNAME _
SUBDIR
REVIEWS
STATUS
REMARKS
NOTES
REVIEW TYPE'
REVIEWER.
SENT DATE
DUE DATE
RETURNED
DATE
NON-STRUCTURAL-
2 WK
BUILDING
BUCKET
8/18/2015
9/1/2015
9/1/2015
REVISIONS REQUIRED
DOC
STRUCTURAL - 2 WK
YOUNG
ENGINEERING
8/18/2015
9/1/2015
8/20/2015
READY FOR APPROVAL
2ND BLDG NS (2
WK)
JIM JOHNSON
9/18/2015
10/2/2015
9/22/2015
APPROVED
BOND INFORMATION
Attachment Type -
CREATED ::..
._: OWNER ;..
ATTACHMENTS
DESCRIPTION
PATHNAME _
SUBDIR
ETRAKIT ENABLED .
DOC
9/10/2015
JIM JOHNSON
49-725 ANACAPA
49-725 ANACAPA
0
CIR..docx
CIR..docx
DOC
9/22/2015
JIM JOHNSON
SCHOOL FEES BRES2015-
SCHOOL FEES BRES2015-
0
0311.pdf
0311.pdf
1ST REVIEW -
NEW CITY
DOC
8/20/2015
KATHRYN SAMUELS
STRUCTURAL
TRANSMITTAL BRES
0
TRANSMITTAL
2015-0311(ist).pdf
HOA APPROVAL FOR
HOA APPROVAL FOR
DOC
9/3/2015
STEPHANIE KHATAMI
METAL WATER CLOSET
METAL WATER CLOSET
0
09-02-15.pdf
09-02-15.pdf
2ND SUBMITTAL CHECK
2ND SUBMITTAL CHECK
DOC
9/18/2015
STEPHANIE KHATAMI
LIST AND COMMENTS
LIST AND COMMENTS
0
ANACAPA.pdf
ANACAPA.pdf
Printed: Friday, October 02, 2015 10:03:13 AM 5 of 5 C ,
SYSTEMS
I
Bin#U&
City of La Quinta .
I Building ar Safety Dh4slon
P.O. Box 1504, 78-495 Calle Tamplco
La Qulnta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Perrnit # �-
-� 1 S
Proj6dAddress: 49-725 Anacapa Circle
owner'$Name: Larry & Morgan Pfeiffer
A.P. Number: -646-210-025
Address: 49-725 Anaca a Circle
Legal Description:
City, sT, zip: La Quinta, CA 92253
Contractor:
Address:
Telephone:
Project Description: Pro 0 odel & addition
City, ST, zip:
of Residence.
Telephone:
w,_5 ., f
'` ' ` tl'� '�
State Lic. #:
City Lic. #:
T
- "
Arch., Engr,, Designer: Gabriel Rios
Address: 49-901 Cinnabar Lane
city, sT, zip: Coachella CA 92253
Telephone: (760) 485-7431
State Lic. #: N/A��`':
.y ; t�: .,. N
•p ''� '
..: w
Construction Type: V -B Occupancy: R-3
Project type (circle one): New Add'n Alter Repair Demo
Name of Contact Person: Gabriel Rios
Sq, Ft.: 334
#Stories: 1
#Units:
Telephone # of Contact Person: 760 485-7431
Estimated Value of Project: $150,000.00
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACMG
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Cates.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calls.
Called Contact Person
Plan Check Balance.
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2id Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE,
''" Reyiew, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit Issue
School Fees
Total Permit Fees
� G�-Lo o
j
Letter'of Transmittal AUG 3 8 2015
To: City of La Quinta Today's Date:
78-495 Calle Tampico City Due Date:
La Quinta, CA 92253 Project Address:
Attn: Kay Plan Check #:
We are forwarding:
Includes: # Of
Copies:
ElElElElEl
L
Submittal: ® 15i
❑ 2nd
❑ 3rd
® By Messenger ❑
Descriptions;
Structural Plans
Structural Calculations
Truss Calculations Floor
and Roof
Soils Report
Structural Comment List
Redlined Structural Plans
Redlined Structural. Calcs
Redlined. Truss Calcs
Redlined Soils Reports
8-20-15 CITY OF LA QUINTA
9-1-15
49-725 Anacapa Cir.
BRES 2015-0311
❑ 4th
❑ 5th
❑ Other:
By Mail (Fed Ex or UPS) ❑ Your Pickup
Includes: # Of Descriptions:
Copies:,
❑
Revised Structural Plans
❑
Revised Struct. Calcs
❑
Revised Truss
❑
Revised Soils Report
❑
Approved Structural Plans
❑
Approved Structural Calcs
❑
Approved -Truss Calcs "
❑
Approved Soils Report
❑
Other:
Comments: Structural content is approvable. /
If you have any questions, please call.
Time = 2 HR
This Material •Sent for:
❑ Your Files ® Per Your Request
❑ Your Review ❑ Approval
❑ Checking ❑ At the request of:
Other: ❑
By: Kathryn Samuels
Palm Desert Office: ® (760)_772-5107
Other: ❑
M
TO: VCYOUNG
ATTN:
TODAY'S DATE: _
PERMIT NUMBER:
PROJECT ADDRESS:
APPLICANT NAME:
SUBMITTAL ROUND:
T`hf 4 4 a"
LA QUINTA, CALIFORNIA 92247-1504
78-495 CALLS TAMPICO
LA QUINTA, CALIFORNIA 92253
TRANSMITTAL
❑ESGIL ❑VCA
INCLUDED HEREWITH:
FLANS nREDLINED, PLANS
CSTRUCT ❑REDLINED STRUCT
❑TRUSS ❑REDLINED TRUSS
❑SOILS ❑REDLINED SOILS
❑ENERGY ❑REVISED ENERGY
{CORRECTION LIST
❑OTHER
BUILDING & SAFETY DEPARTMENT
(760) 777-7125
FAX (760) 777-7011
❑COMPLETE PLAN CIHECK/N/S-STRUCTURAL
1 1
UE DATE:
ol•
❑REVISED PLANS
❑REVISED STRUCT
❑REVISED TRUSS
❑REVISED SOILS
❑APPROVED PLANS
❑APPROVED STRUCT
❑APPROVED TRUSS
❑APPROVED SOILS
❑CUSTOMER RESPONSES
-BUILDING DEPARTMENT USE ONLY-
GREEN SHEET TO: ❑CDD ❑(w/Plans) ❑PUBLIC WORKS ❑COVE CHECK (w/Application)
ASSIGN NON-STRUCTURAL TO:
COMMENTS:
Unit Counts �'
Qty
TOILETS �)
2
BIDET/URINAL
0
SHOWERS �)
2
'BATHTUBS
O
SINKS
*BAR SINK
f
,
BBQ
OVEN
RANGE
COOKTOP
DRINKING FOUNTAIN
WASHER
DRYER
WATER HEATER
ROOF DRAINS
FLOOR DRAINS
4
KITCHEN SINK
VEGGIE SINK
LAUNDRY SINK
FIREPLACE
REVISED: 7/15/2015
NSW FwL= Pir..
wocAs-- Fa 0 -:Z
New a �q N9 C4 -1
Wf.2.
• D" a✓ R ;
RESIDENTIAL
m
ADDRESS
PROJECT DESCRIPTION
IT .
New Constructiorn
CONDITIONED/AC (SF)
GARAGE/UNCOND (SF) -• ' '3
PATIO/COVERED (SF) e
FIRE SPRINKLER (SF)
CODE EDITION
CONSTRUCTION TYPE
11�, GOOD YES / NO
.NUMBER OF FLOORS
NUMBER OF BEDROOMS
NUMBER OF UNITS
OCCUPANT LOAD
OCCUPANCY
MSHCP (DU/ACRE)
(DWELLING UNITS PER ACRE, EX: 43,560SF/7,000SF Lot = 6.22DU/ACRE)
Remodel/Addition
REMODEL AREA (SF) 21 .o
ADDITION AREA (SF)
AWNING/CANOPY (EA)
BALCONY ADDITION (EA)
FIREPLACE (EA)
PARTITION (EA)
STUCCO APPLICATION (SF)
DOOR/WINDOW - REP (EA)
DOOR/WINDOW - NEW (EA)
CARPORT (EA)
VALUATION ($)
(AS SHOWN ON BUILDING APPLICATION)
Grading
TRACT
❑
CUSTOM HOME < =7KSF
❑
CUSTOM HOME > 7KSF
❑
APPLICATION
DATE
Mechanical
Units
FURNACE
2 _
HEATER
i
APPLIANCE (ALT/ADD)
JK /
'COMPRESSOR
2
,%R HANDLER
EVAP COOLER
�U
' VENT FAN
EXH UST HOOD
MISC-MECHANICAL
r
Electrical.
Units
t�
NEW ELECTRICAL (SF)
and/or
RECEP/SW ITCH/LIGHT
r.
Nplus
APPLIANCE - RES
APPLIANCE - NONRES
POWER APPARATUS
j� SIGNS
SERVICE
TEMPORARY SERVICE
MISC ELECTRICAL
. LIGHT POLES
PV SYSTEM - ARRAY
PV SYSTEM - MISC EQ
Plumbing'
'Units
FIXTURE/TRAP
SEWER
SEPTIC
ROOF DRAIN
WATER.HEATER
GREASE INTERCEPTOR
WATER PIPING
BACKFLOW
GAS OUTLETS
REVISED: 7/15/2015 RESIDENTIAL
I T4hf 4 4 a"
COMMUNITY DEVELOPMENT DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
(.760) 777-7125 FAX (760) 777-7011
RESIDENTIAL PLAN CHECK CORRECTION LIST (os)
DATE: 9/1/2015
STATUS: FIRST REVIEW
PLAN CHECKED BY: JIM JOHNSON
TELEPHONE NUMBER: (760) 777-7130
ADDRESS: 49-725 ANACAPA CIR
DESCRIPTION: REM / ADDITION
APPLICANT: PFEIFFER
PLAN CHECK #: BRES2015-0311
This submittal has been checked for compliance with the 2013 California Residential, Mechanical, Electrical,
Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code.
APPLICANT: BUILDING DEPARTMENT STAFF:
The following items are being returned to you for DO NOT accept any resubmittal unless ALL of the
correction: following items are included:
3 SETS OF PLANS
2 SETS TITLE -24
2 SETS STRUC CALCS
THIS CORRECTION LIST
j,,AEDLINED SETS
L -2 -NEW REVISED SETS
t,,KSSESSORS SET
2 SETS TITLE -24
L-2 SETS STRUC CALCS
THIS CORRECTION LIST / RESPONSES
'4.�ASBESTOS REPORT REQUIRED.
INSTRUCTIONS TO APPLICANT:
1) Provide a written response to each comment on the following pages, noting specifically where the correction
can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not
acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses
such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check.
2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or
Calculations as necessary.
3) Return all red -marked Plans and/or Calculations with your resubmittal.
4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number
and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and
Professions Code Section 5536. Resubmittals will not be accepted with signatures missing.,
5) Return this list, your written responses, and all documents listed above with your resubmittal.
Residential Plan Check Correction List Pagel of 3
City of La Quinta Plan Check # BRES2015-0311
49-725 Anacapa Cir.
Responses to Plan check: Delta 1
Section A - General
1. See added missing structural Sheet S-5.0
2. See all sheets signed on plans.
Section C — Architectural
1. See revised note #27, under floor plan notes on sheet A2.1.
Section F — Plumbing
1. See added sheet A7.0, Plumbing Floor Plan & Waste & Vent Schematics, added to plans.
Section G — Energy Efficiency
1. See revised title 24's paper copies & on the T24 sheet for proper sq. footages revised.
2. See revised floor plan i -at all windows for added U -Factor & SHGC's numbers which
correspond with title 24's.
SECTION A - GENERAL
1) Sheet Index does not reflect actual sheets in Plans. Reconcile. MISSING S-5.0 IN NON- STRUC SET
2) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and
telephone number and wet -signature. If the preparer is a licensed architect or engineer, all documents
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and
Professions Code §5536. Resubmittals will not be accepted with signatures missing.
SECTION C - ARCHITECTURAL
1) Specify a self-closing, self -latching door fire rated attic access in cart garage.
SECTION F - PLUMBING
1) Provide a schematic drainage piping plan showing all fixtures (and fixture unit counts), waste and vent sizes,
and cleanout locations. (CPC Chapter 7 and Tables 7-3 through 7-6) NEW HALL BATHROOM.
SECTION G — ENERGY EFFICIENCY
1) Conditioned floor area on Plans does not match Energy Calculations. Reconcile. TITLE 24 SHOWS ALL
NEW SQ. FT. CART GARAGE AND NEW A/C SPACE 334 SQ. FT. IT SHOULD SHOW 138 SQ. FT.
CART GARAGE AND 206 A/C ADDITION.
Informational Items: Conditioned floor area (CFA) is the total floor area (in square feet) of enclosed conditioned
space on all floors of a building, as measured at the floor level of the exterior surfaces of exterior walls
enclosing the conditioned space. [§ 10 1] This term is also referred to in the standards simply as the floor area.
This is an important value for the purpose of compliance since annual energy use is divided by this value to obtain
the energy budget. CFA is calculated from the plan dimensions of the building including the floor area of all
conditioned and indirectly conditioned space on all floors. It includes lofts and mezzanines but does not include
covered walkways, open roofed -over areas, porches, pipe trenches, exterior terraces or steps, chimneys, roof
overhangs or parking garages. Unheated basements or closets for central gas forced air furnaces are also not
included unless shown to be indirectly conditioned. The floor area of an interior stairway is determined as the
CFA beneath the stairs and the tread area of the stairs themselves. (Residential Compliance Manual § 1.8
Conditioned Floor Area)
2) Specify the following information from Energy Calculations at each glazed opening (window, door, skylight)
on the Floor Plan, or in a schedule:
a) Area of glazing (in square feet)
b) Required U -factor
c) Energy Calculation Fenestration Number
SECTION I - STRUCTURAL
1) See separate structural correction list, attached. STRUC APPROVED
Important note to Engineer of Record:
If these corrections require revisions to structural calculations, in response to these corrections, do NOT simply
submit two copies of a few supplemental calculations.
For resubmittal, include:
Residential Plan Check Correction List
J,
Page 2 of 3
City of La Quinta
SECTION K - MISCELLANEOUS COMMENTS
1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise
Plans as necessary and provide written response, noting where correction can be found.
2) Provide letter of approval from Homeowners' Association.
3) Inadequate information has been provided at.this submittal to calculate fees for this project. Fee calculation
will be performed when Plans are complete.
END CORRECTION LIST
As further information is provided and reviewed, additional corrections may be required.
Residential Plan Check Correction List Page 3 of 3
From: Kathy Penfold k.penfold7Ogmail.com (f
Subject: Re: Pfeiffer Hot water heater closets �` 5£ .
Date: September 2, 2015 at 10:19 AM
To: Marianne Nouskajian mariannenouskaiian@yahoo.com
Here it is.
K
On Wed, Sep 2, 2015 at 9:34 AM, Marianne Nouskajian <mariannenouskajian@yahoo.com> wrote:
Attached is the letter. Please sign and return to me asap. If you can not scan and send, please send an email with your
approval and stating your title on the board and the date.
Thank you,
Marianne
September 2, 2015
To whom it may concern:
The Board of Islands HOW, La Quinta Country Club, has
approved the metal type closets for the hot water heaters
at the Pfeiffer residence located at 49725 Anacapa Circle,
La Quinta, CA 92253.
Jo Downey, President
Nouskajian, Vi
Kathy Pen d. Secrelfiry Treasurer
.,-
From: JO Downey downeyio@aol.com
Subject: Re: Pfeiffer Hot water heater closets C
Date: September 2, 2015 at 1024 AM
To: Marianne Nouskajian mariannenouskajian@yahoo.com
Cc: Brooke Ancheta bancheta@drmintemet.com, Cherri Hairston chairston@drminternet.com, Kathy Penfold k.penfold7@gmail.com
I approve. Sept. 2, 2015
Jo Downey, president
Sent from my iPad
On Sep 2, 2015, at 9:34 AM, Marianne Nouskajian <mariannenouskajian@yahoo.com> wrote:
Attached is the letter. Please sign and return to me asap. If you can not scan and send, please send an email with your
approval and stating your title on the board and the date.
Thank you,
Marianne
<Hot water heater closets.pdf>
T4-hf 4 4 a"
COMMUNITY DEVELOPMENT DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
(760) 777-7012 FAX (760) 777-7011
CERTIFICATION OF BUILDING AREA
STREET ADDRESS OF JOB: 49-725 ANACAPA CIR.
APN: 646-210-025
DESCRIPTION OF WORK: REM / ADDITION
SQUARE FOOTAGE: 206 SQ. FT.
OWNER'S NAME: PFEIFFER
For questions regarding this letter, please call:
City of La Quinta Permit Center
(760) 777-7012
Coachella Valley Unified School District
83-733 Avenue 55
P 0 Box 847
Thermal, CA 92274
(760) 398-5909
Desert Sands Unified School District
47-950 Dune Palms Road
La Quinta, CA 92253
(760) 771-8515
I CITY OF LA QUINTA
BUILDING & SAFETY
FOR CONSTUCTIOt4
"SATE -_q = BY_
Please note: This letter verifies conditioned square footage. Please can
your School District to verify school fees, requirement for cashier's check
or money order and hours of operation.
TERRA
ENVIRONMENTAL
October 1, 2015
Asbestos Air Clearance
49725 Anacapa Cr. La Quinta, CA 92253
Prepared for:
Hector Gutierrez
Superior Environmental
Re:
Acoustic Spray Removal
Terra Environmental performed PCM final air testing at a Single Family Residence located at
49725 Anacapa Circle in La Quinta, CA. Following the removal and cleanup of approximately 1200
SF of asbestos containing acoustic spray from the Dining room, bedrooms (3) and laundry room.
Terra Environmental collected PCM air clearance samples inside the work areas. The sample
analysis revealed fiber concentrations bellow 0.01 F/CC. Based on the sample analysis and visual
inspection,, Terra Concludes the Cleanup and removal activities performed by Superior
Environmental, were successful and the work areas_ meet the regulatory standards for general re -
occupancy without respirators.
Israel Monsalvo, CAC, CDPH-I/A & PM
Cal/OSHA-Certified Asbestos Consultant #04-3551
California Department of Public Health -Certified I/A, PM # 9699
12631 Imperial Hwy Suite A225. Santa Fe Springs, CA 90670
www.terraeng.com
•!��"::: TERRA
•• •�
�, �:•�� ENVIRONMENTAL
ASBESTOS STATEMENT OF CLEARANCE
PROJECT N0:
CLIENT:
DATE:
7583
SUPERIOR ENVIRONMENTAL
SEPTEMBER 30, 2015
PROJECT NAME:
TERRA ENVIRONMENTAL SERVICES REPRESENTATIVE:
SINGLE FAMILY RESIDENC
ISRAEL MONSALVO
PROJECT LOCATION
WORK AREAS:
49725 ANACAPA CIRCLE
DINING ROOM, BEDROOMS AND LAUNDRY ROOM
THE SURVEY REPORT, PROJECT PLANS & SPECIFICATIONS.
CONTRACTOR:
LA WNTA, CA 92253
SUPERIOR ENVIRONMENTAL
SCOPE OF ASBESTOS RELATED WORK
MATERIAL 1 ACM ACOUSTIC SPRAY 1200 SF
MATERIAL 2
MATERIAL 3
MATERIAL 4.
CONTAINMENT CLEANLINESS:
ABATED SURFACES FREE OF VISIBLE, SUSPECT DEBRIS
WALLS AND FLOORS FREE OF VISIBLE, SUSPECT DEBRIS
ABATED SURFACES THOROUGHLY ENCAPSULATED
WALLS AND FLOORS THOROUGHLY ENCAPSULATED
FINAL CLEARANCE AIR SAMPLES
ALL PHASE CONTRAST MICROSCOPY (PCM) SAMPLES EQUAL TO OR LESS
THAN 0.010 PER CU131C CENTIMITER OF AIR (F/CC)
AVERAGE OF ALL TRANSMISSION ELECTRON MICROSCOPY (TEM) SAMPLES
EQUAL TO OR LESS THAN 70 STRUCTURES PER SQUARE MILIMITER (S/MM2)
PASS
FAIL
NIA
X
FC -01 0.0042 F/CC
FC -05 FIELD BLANK
X
FC -06 SEALED BLANK
X
X
FC -04 0.0056 F/CC
X
CLEARED AFTER ASBES OS ABATEMENT IN ACCORDANCE WITH
THE SURVEY REPORT, PROJECT PLANS & SPECIFICATIONS.
PASS
FAIL
NIA
X
FC -01 0.0042 F/CC
FC -05 FIELD BLANK
FC -02 0.0035 F/CC
FC -06 SEALED BLANK
X
AS DEMONSTRATED BY THE RESULTS BELOW FROM THE AIR SAMPLES COLLECTED FOR FINAL CLEARANCE AND THE VISUAL
INSPECTION, THE AREA MEETS THE US EPA STANDARD FOR RE -OCCUPANCY WITHOUT RESPIRATORY PROTECTION.
SAMPLE ID FIBER CONC. (FICC) OR
SAMPLE ID FIBER CONC. (FICC) OR
STRUC. DENSITY (STRUC./ MM2)
STRUC. DENSITY (STRUC./ MM2)
FC -01 0.0042 F/CC
FC -05 FIELD BLANK
FC -02 0.0035 F/CC
FC -06 SEALED BLANK
FC -03 0.0050 F/CC
FC -04 0.0056 F/CC
I HEREBY CERTIFY THAT THE AREA IDENTIFIED BELOW HAS BEEN
CLEARED AFTER ASBES OS ABATEMENT IN ACCORDANCE WITH
THE SURVEY REPORT, PROJECT PLANS & SPECIFICATIONS.
ISRAEL MONSALVO
October 1, 2015
TERRA REPRESENTATIVE: NAME
SIGN RE DATE
12631 Imperial Hwy Suite A225. Santa Fe Springs, CA 90670
www.terraeng.com
Client:
Project:yG►/��—
Address:
0
N� TERRA
ENVIRONMENTAL
ASBESTOS AIR MONITORING
Date: SSP 30 , 20/S
SAMPLE ID
NUMBER
SAMPLE TYPE
SAMPLE LOCATION
INITIAL FLOW
RATE
FINAL FLOW
RATE LITIMIN
TIME ON
TIME OFF
TOTAL
MINUTES (MIN)
TOTAL
VOLUME (LIT)
FIBERS
FIELDS
LABORATORY RESULTS
� C �
dGCw��C
�3
17-��
/OS�
g2
/Z515®a
D�o®3S
Iosq
13
s 6
093
g2
1257-5
,8vonl�C
q
�p a
RELINQUISHED BY
DATE
TIME
RECEIVED BY
DATE
TIME
ANALYSED BY /
DATE
TIME �7 /
NIUJFi /4UU
12631 IMPERIAL HWY STE A225. SANTA FE SPRINGS, CA 90670
www.terraeng.com
TERRA
ENVIRONMENTAL
State of California Department of Public_ Health,
Lead -Related rt are FxgfrgjW
Construction UN Wee
Certificate Inspector/Assessor 09/01/2015
State of California
Division of Occupational Safety and Health
Certified Asbestos Consultant
Israel
Certifficati
This ce at -on sued' thg• i ion of
occupalio t" h 'lauthodzed
by Sections usiness and
I Professions Code.
Israel Monsalvo, C, CDPH-I/A & PM
Cal/OSHA-Certified Asbestos Consultant #04-3551
California Department of Public Health -Certified I/A, PM # 9699
12631 Imperial Hwy Suite A225. Santa Fe Springs, CA 90670
Ph (562) 868-3777 www.terraena.com
P.O. BOX 1504
LA QUINTA; CALIFORNIA 92247-1504
78-495 CALLS TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
PROPERTY OWNER'S PACKAGE
(760) 777-7012
FAX (760) 777-7011
Disclosures & Forms for Owner -Builders Applying for Construction Permits
Dear Property owner.
An. application for a buil ' 't hasz#w submi your yourse the builder of the property
improvements specified at ,Z
We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your
responsibilities and possible risk you racy incur by having this permit issued in your name as the
Oemnar-Builder. We will not Issue a building permit until ywn have read, milia W your anders nding of each provtcioa,
signed, and returned this form to us at our Metal address indicated. An agent of the owner cannot execute this notice
unless you, the property owner, obtain the prior approval of the permitting authority.
OZ'S NCKNMW%EDE` w•'r ANDWRRIFI_ A4'10N OF
22QR11+lEhM0N
DMEMONS. Read and iridal each statement below to signify you underatwtd or verb+ Als information.
1. I understand a frequent practice of unlicensed persons is to have the property dwner obtain an "Owner -Builder"
Y4ding permit that ettoneously implies that the property owner is providing his or her own labor and material personally. I, as
an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while working on my property. My homeowner's insuranco may not provide coverage for those
igiuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance -coverage for injuries to workers
on MY ply.
eW*i understand building permits are not required to be signed by property owners unless they are responsible for the
tr�ction and are not hiring a licensed Contractor to assume this responsibility.
f j�D 3. I understand as an "Owner -Builder" I am the responsible party of record on the permit. I un&rstand that I may protect
from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my
own.
4.1 understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on
its and contracts.
WS. i understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value
my construction is at least five hundred dollars (5500), including labor and materials, I may be considered an `employer"
4cmder state and federal law.
6. I understand if I am considered an "employee' under state and federal law, I must register with the state and federal
ment, withhold payroll taxes, provide woikers' compensation disability insurance, and contribute to unemployment
compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial
icturcs
7. 1 understand under California Contractors' State license Law, an Owner -Builder who builds single-family residential
cannot legally build them with the intent to offer them for sale, unless at( work is performed by licensed
subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed
under contract with a licensed general building Contractor.
I understand as an Owner -Builder if I sell the property for which this permit is issued, l may be held liable for any
sial or personal, 4arim awa&od by any subsequent owne(s) that result from any latent construction defects in the
workmanship or materials.
I understand I may obtain more information regarding my obligations as an "employer" from thb Internal Rovenue
wise, the United States Small Business Administration, the California Department of Beaefit Payments, and the California,
Division of Industrial Accidents, I also understand I may contact the California Contractors' State License Board (CSLB) at 1-
800.321-CSL9 (2752) or www,cslb.mSov for more information about licenced contractors.
YK14.1 am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the
legally and financially responsible , for proposed ,construction activity at the following address:
I L I Agree that, as the party legally and Onaucially responsible for "proposed construction activity, l will abide by all
cable laws and requirements that govern Owna-Suilders as well as employers.
12.1 agree to notify the issuer of this form immodiateiy of any additions, dcic6a i, or changes to any of the information I
e provided on this farm, Licensed oontmetors aro regulated by laws designed to protect the public. If you contract with
siornoone who does not have a hoease, the Contractors' State License Dead may be unable to +
you may sustain as a result of a complaint Your only remedy against unlicensed Contractors may be in civil court. It is also
important for you tounderstand that if an unlicensed Contractor or employee of that individual or firm is injured while woddag
on your property., you may be held Habib for damages. If you obtain a permit as Owner -Builder and wish to hire Coahacoors,
you wdl ba responsible for verWfing vhethw or not those Contractors ars properly licensed and the status of their workers'
con don insurance coverago.
Before a building permit can be issued, this form must be completed and signed by the property owner And returned to
the agency responsible for bsub* the pertsdt. Nos: ,4 copy of tke p petV owner's dsber'r farm motardbautibu► or
other verification accVtable to the agency is regrralrod to be presented whet aha permit is i=64 to verb the prop"
Note., lite following`Authori do o re red to be completed by the property owner only when designating
an agent of the property at to app y f a conduction permit for the Owner -Builder.
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEBAI.F
Excluding the Notice to Property Owner, the execration of which I understand is my personal, responsibility, I hereby authorize
the following person(s) to act as my ogent(s) to apply for, sign, and file the documents necessary to obtain an Ownet-Buildei
Permit for my project J j
Scope of Construction Project (or Description of Work): rt? )11 Odd ( 1 o I 'L' r i o ✓-
�1q r
Project Location or Address: ,'�7,'t �}Y( "� 1 /
Name of Authorized Agent: 1 ill Zt /i 11 %�i%I j Oki �% s? !7 Tel No (ta O) 7 U
-� 7
Address of Authorized Agent: �� 7/ �/% 1r f! R�%A' el i t5Z
I declare under penalty of perjury than I am the
information and certify its accuracy. Mote: A cq
acceptable to the agency is
Property Ownees Signature:
owner for the address listed above and I personally filled out the above
owner's driver's license, form notarization, or other verification
ejjre peiVit is issued to verb the property owner's signature.
Date:
KRP A
MSAS DL
CO MCLS N Com&j Cls C
010
IssEXP 11-12.2016
SEX F NT•6 QS EY6s HAZ wr 116
00911.12-1951 ENORs
? ORGAN DONOR r
�Q'.C•f
4y p
_
y�
Bveou a�f4WH{A 111
Date: 9/22/2015
No.: 15-00023-1
Owner: Pfeiffer
Address: 49725 Anacapa Circle
City: La Quinta
Type: Residential Addition < 500 sq ft
Lot # Street No.
49275
Comments:
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
La Qunita, CA 92253
(760)771-8515
Street Name
Anacapa•Circle
JN�fien s
c
0
ZQy'° 6
ill B8ERMUDA DUNES -
RANCMoMIRAGE
t�INDllIN WEC1S'; y`
iL -PALMQE SERT> Y
�=CDAgiELtA:'D
s',�j�tA INTA.7•
Email:
Jurisdiction: La Quinta
Tract #:
Sq. Feet APN Permit No.
206 646-210-025
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
Exempt
This certifies that school facility fess imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 206 S.F. or $0.00 have been paid for the property listed above and that building permits
and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Fees Paid By: Exempt - John Nouskajian Check No.:
Bank Name/Recipient of Certificate Telephone: 626-818-7123
Funding: Exempt
By Dr. Gary Rutherford
Superintendent
Fee Collected/ Exem ted by: Sharon McG' rey e --,,,A, mount`Due: $0,00
Original .Payment(s)`Rec'd: $0.00
2 .w�
hew:Payment,Rec'd: $0.00
Omer/Under: $0.00
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in.wnich you may protest the fees or
�
other payment identified above will begin to run from the date on which the building or installation permit for this project is,issue�ad,•or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
49 A ti�.� A.�a c ip,
.ARES 3-11
BUILDING ENERGY ANALYSIS REPORT
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPI� VE®
FOR CONST UCTION
PROJECT:
DATE 1f22[IPfeiffer
- -J B
Residence
9-725 Anacapa Circle
La Quinta, CA
Project Designer:
Report Prepared by:
Joan D. Hacker
Insu-form, Inc.
77810 Las Montanas Road, Suite 201
Palm Desert, Ca 922,11
760-345-1352
Job Number:
Date: CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
9/15/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
Ener Pro 6.7 by Ener Sof User Number. 2655 ID.
I TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF -1 R -PRF -01-E Certificate of Compliance 3
Form RMS -1 Residential Measures Summary 11
Form MF -1 R Mandatory Measures Summary12
HVAC System Heating and Cooling Loads Summary 16
EnergyPro 6.7 by EnergySoft Job Number: I0: User Number. 2655
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Daterrime: 15:40, Tue, Sep 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Pfeiffer Exist Addition.xml
CF1 R -PRF -01
Page 1 of 8
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name Single Fam Detached
04
05
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location 49-725 Anacapa Circle
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 0
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2) 2308
15
Number of Zones 2
16
Slab Area (ft2) 2308
17
Number of Stories 1
18
Addition Cond. Floor Area 206
19
Natural Gas Available Yes
20
Addition Slab Area (ft2) 206
21
Glazing Percentage (%) 10.8%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
03 This building incorporates one or more Special Features shown below
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - C17111-08252015-744 Report Generated at: 2015-09-15 15:40:02
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
7.83
7.55
0.28
3.6%
Space Cooling
157.16
156.75
0.41
0.3%
IAO Ventilation
0.00
0.00
0.00
0.0%
Water Heating
14.54
12.58
1.96
13.5%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
179.53
176.88
2.65
1.5%
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - C17111-08252015-744 Report Generated at: 2015-09-15 15:40:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached
Calculation Description: Title 24 Analysis
Calculation Date/Time: 15:40, Tue, Sep 15, 2015
Input File Name: Pfeiffer Exist Addition.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Cathedral Ceiling
• Window overhangs and/or fins
HERS FEATURE SUMMARY
CF1 R -PRF -01
Page 2 of 8
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• —None --
Cooling System Verifications:
• —None --
HVAC Distribution System Verifications:
• — None --
Domestic Hot Water System Verifications:
• — None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)* 225.01 222.36 2.65 1.2%
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (112)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Single Fam Detached
2308
1
6
2
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Existing Living
Conditioned
Living Zone1
2102
9
DHW Sys 1
Addition
Conditioned
Living Zone1
206
9
DHW Sys 1:d
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-09-15 15:40:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 15:40, Tue, Sep 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Pfeiffer Exist Addition.xml
CF1 R -PRF -01
Page 3 of 8
OPAQUE SURFACES
01
02
03
04
05
06
06
07
08
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door
Area (ft)
Tilt
(deg)
Status
Verified
Existing
Condition
Front Wall
Existing Living
Default Wall 1978 to 1991
0
Front
1300
17.9968
90
Existing
No
Left Wall
Existing Living
Default Wall 1978 to 1991
90
Left
950
46.5
90
Existing
No
Rear Wall
Existing Living
Default Wall 1978 to 1991
180
Back
1300
181.421
90
Existing
No
Right Wall
Existing Living
Default Wall 1978 to 1991
270
Right
1200
90
Existing
No
Roof 2
Existing Living
Roof Rigid
2098
Altered
N/A
Front Wall 2
Addition
R-13 Wall
0
Front
50
90
New
N/A
Left Wall 2
Addition
R-13 Wall
90
Left
5
90
New
N/A
Rear Wall 2
Addition
R-13 Wall
180
Back
2
90
New
N/A
Right Wall 2
Addition
R-13 Wall
270
Right
4
90
New
N/A
Roof 3
Addition
Roof Rigid
206
New
N/A
OPAQUE SURFACES — Cathedral Ceilings
01
02
03
04
05
06
06
07
08
09
10
11
12
13
Name
Zone
Type
Orientatio
n
Area
(ft)
Skylight
Area (ft2)
Roof Rise
(x in 12)
Roof
Pitch
Roof
Tilt(deg)
Roof
Reflectan
ce
Roof
Emittance
Framin
g
Factor
Status
Verified
Existing
Condifion
Roof
Existing Living
Roof Rigidt
Front
4.1
4
0
0
0
0.1
0.85
0.1
Altered
N/A
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant
Barrier
Cool Roof
Statu
s
Verified Existing
Condition
Attic Existing Living
Attic RoofExisting Living
Ventilated
0
0.1
0.85
No
No
Altdere
No
Attic Addition
Attic RoofAddition
Ventilated
0
0.1
0.85
No
No
New
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744 Report Generated at: 2015-09-15 15:40:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 15:40, Tue, Sep 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Pfeiffer Exist Addition.xml
CF1 R -PRF -01
Page 4 of 8
WINDOWS
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Height (ft)
Multiplie
r
Area (W)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
Window
Front Wall (Front -0)
4.0
2.0
1.25
10.0
0.40
0.26
Insect Screen (default)
Altered
N/A
Window 2
Front Wall (Front -0)
1.4
6.0
0.952
8.0
0.40
0.26
Insect Screen (default)
Altered
N/A
Window 3
Left Wall (Left -90)
2.0
2.0
1
4.0
0.71
0.73
Insect Screen (default)
Existing
No
Window 4
Left Wall (Left -90)
2.5
4.0
1
10.0
0.40
0.26
Insect Screen (default)
Altered
N/A
Window 5
Left Wall (Left -90)
2.5
4.0
1
10.0
0.40
0.26
Insect Screen (default)
Altered
N/A
Window 6
Left Wall (Left -90)
6.0
3.0
1 •
18.0
0.40
0.26
Insect Screen (default)
Altered
N/A
Window 7
Left Wall (Left -90)
3.0
6.0
0.25
4.5
0.40
0.26
Insect Screen (default)
Altered
N/A
Window 8
Rear Wall (Back -180)
8.0
6.8
0.982
53.4
0.71
0.73
Insect Screen (default)
Existing
No
Window 9
Rear Wall (Back -180)
16.0
8.0
1
128.0
0.40
0.26
Insect Screen (default)
Altered
N/A
Skylight
Roof (Front -0)
----
----
1
4.0
0.71
0.73
None
Existing
No
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12 13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up Dist R
Bot Up
Window
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 2
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 3
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 4
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 5
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 6
2
0.1
2
2
0 1
0
0
0
0
0
0 0
0
Window 7
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 8
2
0.1
2
2
0
0
0
0
0
0
0 0
0
Window 9
2
0.1
2
2
0
4
0
0.1
0
4
0 0.1
0
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08252015-744
HERS Provider:
Report Generated at: 2015-09-15 15:40:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation DatefTime: 15:40, Tue, Sep 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Pfeiffer Exist Addition.xml
CF1 R -PRF -01
Page 5 of 8
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
09
Name
Zone
Total Cavity
Winter Design
Edge Insul. R -value
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
620
None
0.8
No
Existing
No
• Cavity/Frame: no insul. /2x4 Top Chrd
Addition
206
2
None
0.8
No
• Roof Deck. Wood Siding/sheathing/decking
No
2x4 Top Chord of Roof Truss @ 24
• Above Deck Insulation: R1 f Sheathing
Attic Roof Existing Living
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.079
• Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity/Frame: R-11 /2x4
• Exterior Finish: Wood
Default Wall 1978 to 1991
Exterior Walls
Wood Framed Wall
2x4 ® 16 in. O.C.
R 11
0.103
Siding/sheathing/decking
Ceilings (below
• Inside Finish: Gypsum Board
Roof Rigid
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
none
0.472
• Cavity/ Frame: no insul. /2x4
• Inside Finish: Gypsum Board
• Cavity/Frame: no insul. /2x4
• Roof Deck: Wood Siding/sheathing/decking
• Above Deck Insulation: R1 f Sheathing
Roof Rigida
Cathedral Ceilings
Wood Framed Ceiling
2x4 @ 16 in. O.C.
none
0.076
• Roofing: Light Roof (Asphalt Shingle)
• Cavity/ Frame: no insul. /2x4 Top Chrd
• Roof Deck: Wood Siding/sheathing/decking
2x4 Top Chord of Roof Truss @ 24
• Above Deck Insulation: R10 Sheathing
Attic RoofAddition
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.086
• Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity/Frame: R -13/2x4
• Exterior Finish: Wood
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/decking
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft2)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Covered Slab
Existing Living
2102
620
None
0.8
No
Existing
No
Slab -on -Grade
Addition
206
2
None
0.8
No
New
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (011) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required ---
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - C17111-08252015-744 Report Generated at: 2015-09-15 15:40:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 15:40, Tue, Sep 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Pfeiffer Exist Addition.xml
CF1 R -PRF -01
Page 6 of 8
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
2
Annual
Altered
No
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.65 EF
43000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation with
Manual Control
Recirculation with
Sensor Control
DHW Sys 1
n/a
n/a
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
Heating System
Cooling System
Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
Living Zonal
Other Heating and
Heating
Yes
Cooling
N0
Air Distribution
HVAC Fan
2308
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 78 AFUE
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-09-15 15:40:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 15:40, Tue, Sep 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Pfeiffer Exist Addition.xml
CF1 R -PRF -01
Page 7 of 8
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
07
08
Efficiency
10
Multi -speed
Verified Duct Location
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
DuctlessSplitAirCond - Ductless
10
12
No
No
N/A
Location
mini -split and multi -split heat A/C
Status
Condition
Verification
Air Distribution
Ducts located in attic
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Duct Leakage
Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
8.0
Attic
Attic
None
Existing
No
N/A
System 1
specified)
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05 06
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct Location
Verified Duct Design
Return Supply
Air Distribution System 1 -hers -dist
N/A
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAO CFM IAO Fan Type IAO Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-09-15 15:40:02
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Fam Detached Calculation Date/Time: 15:40, Tue, Sep 15, 2015
Calculation Description: Title 24 Analysis
Input File Name: Pfeiffer Exist Addition.xml
CFI R -PRF -01
Page 8of8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Joan D. Hacker
Company:
Signature Date:
Insu-form, Inc.
9/15/2015
Address:
CEA/HERS Certification Identification (If applicable):
77810 Las Montanas Road, Suite 201
City/StatePaDesert, Ca 92211
Phone:
760-345-1352
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of pedury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit applicati n.
Responsible Designer Name:
Responsible Designer Signature:
Gabriel Rios
'
Company:
Date Signed:
Rios Designs
09/16/2015
Address:
License:
49-901 Cinnabar Lane
N/A
City/State/Zip:
Phone:
Coachella, CA 92236
(760) 485-7431
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08252015-744
HERS Provider:
Report Generated at: 2015-09-15 15:40:02
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Pfeiffer Residence
Building Type
10 Single Family ❑ Addition Alone
❑ Multi Family 10 Existing+ Addition/Alteration 1911512015
Date
Project Address
49-725 Anacapa Circle La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,308
Addition
206
# of Units
1
INSULATION
Construction Type
Cavity
Area
(ft) Special Features Status
Slab Unheated Slab-on-Grade - no insulation
2,102 Perim = 620' Existing
Wall Wood Framed R11
4,505 Existing
Roof Wood Framed Attic - no insulation
2098 Rigid=R-11.0 Altered
Wall Wood Framed R 13 -
61 New
Roof Wood Framed - no insulation
206 Rigid=R-14.0 New
Slab Unheated Slab-on-Grade - no insulation
206 Perim = 2' New
FENESTRATION Total Area: 2501 Glazirig Percentage: 10.8 New/Altered Average U-Factor: 0.40
Orientation Area(ft) U-Fac SHGC Overhang Sidefins Exterior Shades Status
Front (N) 18.0 0.400
0.26 2.0
none Bug Screen Altered
Left (E) 4.0 0.710
0.73 2.0
none Bug Screen Existing
Left (E) 42.5 a400
0.26 2.0
none Bug Screen Altered
Rear (S) 53.4 0.710
0.73 2.0
none Bug Screen Existing
Rear (S) 128.0 0.400
0.26 2.0
4.00/4.00 Bug Screen Altered
Skylight 4.0 0.710
0.73 none
none None Existing
HVAC SYSTEMS
-Qty. Heating Min. Eff
Cooling
Min. Eff Thermostat Status
2 Central Furnace 78% AFUE
Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Cooling
Duct
Duct Location R-Value Status
Living Zone Ductless / with Fan
Ductless
n/a n/a
Existing
WATER HEATING
MY. TYPe Gallons Min. Eff Distribution Status
2 Small Storage Gas 50
a65
Standard Altered
Energ vPro 6.7 b y Energ ySoft User Number: 2655
RunCode: 2015-09-15T15:42:01 ID:
Pae 11 of 16
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§ 110.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of § 10-11l(a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110 8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of cool roof is specified on the CFI R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ 150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ I50.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§150.0(g)]:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-I6 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
§150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class lI vapor retarder shall be placed over the earth floor of
§150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e)I A:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)I B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible operable, and tight -fitting damper or a combustion -air control device.
§ 150.0(e)l C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §I 10.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§I50.0(h)1:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in § 15 0. 0 h 2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§ 150.00) l A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R -I2 or greater.
§ 150.00)1 B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§ 150.00)2C:
Pipe for cooling system lines shall be insulated as specified in § I50.06)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§I50.06)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Cl ass I
§ I50.00)3B:
or Class H vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class 11 vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater, a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 18113 or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/a inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ 150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ 150.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
150.0(m) 12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150,0(m)13:
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§150,0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of>_ 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic
testing,in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§I50.0(o)lA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ I I0.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9.
§ 150.0(k)] A:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § I50.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-13, as applicable.
§ I50.0(k)1B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)1C:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§ 150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§ 150.0(k)]F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ I50.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if. it functions as a dimmer
§ 150.0(k)2G:
according to §110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in § 150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§ 150.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to 110.9, and complies with all other applicable requirements in § 150.0 2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ 150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testingtrating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ 150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ ] 50.0(k)9B:
following requirements:
i. Shall comply with §I50.0(k)9A; or
ii. Shall comply with the applicable requirements in §110.9, §130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § ] 50.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9 § 130.0 130.2 § 130.4 § 140.7 and § 141.0.
§ ] 50.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in 110.9 130.0 130.2 130.4 140.7 and 141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ 150.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9 130.0 130.1 § 130.4 § 140.6 and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ I50.0(k)]2B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10 b through § 110.10(e).
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(6) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§1 10.10(b)]:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 1 10.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric'.
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Pfeiffer Residence
Date
9/15/2015
System Name
Living Zone
Floor Area
2,308
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 2,540
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System
70,000
38,421
2,160 1,847
58,510
Total Output Btuh
140,000
0
Output 13tuh/s
60.7
0
0
Cooling System
0
0
Output per System
58,000
0
0 0
0
Total Output 13tuh
116,000
0
27160
0
Total Output ons
9.7
0
0
Total Output 13tuh/s
50.3
Total Output s on
238.8
1 38,421
58,510
Air System
CFM per System
2,210
HVAC EQUIPMENT SELECTION
Alrflow cfm
4,420
Existing 66,869 40,888
140,000
Airflow cfm/s
1.92
Airflow cfm/Ton
457.2
Outside Alr %
0.0%
Total Adjusted System Output 1 66,869 40,888
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
140,000
Outside Air cfm/s 0.00
Note: values above given at ARI conditions
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
70 OF
70 OF 100 OF 100 OF
f C►) �
—' Ll LU
Heating Coil Supply Fan
100 OF
4,420 cfm
ROOM
70 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112178 OF
Outside AirAr
0 cfm
78168 OF
78168 OF 64 / 63 OF 64163 OF
Cooling Coil Supply Fan 64 ! 63 OF
4,420 cfm ;------------__.._
59.2% ROOM
78 ` 68 OF
EnergyPro 6.7 by EnergySoft
User Number 2655 RunCode: 2015-09-15715:42:01 ID: Page 16 of 16