BWFE2015-029378-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
c&t!t 4 4 Quiot.rcv
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number:
BWFE2015-0293
Property Address:
57823 BARRISTO CIR
APN:
762500010
Application Description:
SANTERRA / LEGACY HOMES BLOCK WALL 81 LF
Property Zoning:
Application Valuation:
$2,000.00
Applicant:
CD
MURRIETA APARTMENT INV
37
400 E RINCON STE 105
CORONA, CA 0
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: R License No.: 934711
Dat /D_ /' �1 Contractor'
OWNER -BUIL DECLARATION
I hereby affirm under penalty of perju at I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner.of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. B.&P.C. for this reason
Date
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
i i,11110i
30
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: .10/21/2015
Owner:
MURRIETA APARTMENT INV 37
400 E RINCON STE 105
CORONA, CA 0 ►t?
Contractor:
M H P BUILDERS INC
3202 WEST MARCH LANE S
STOCKTON, CA 95219
(209)951-6190
Llc. No.: 934711
WORKER'S COMPENSATION DECLARATION
hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
KK
provided ,for the performance
ich this pand will mnce, as required by
e Labor Cfor which this permit
kers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subjec to the workers'
compensation laws of California, and agree that, if I should beco a subject to the
workers' compensation provisions of Sectio 0 of ode, I shall forthwith
comply with those provisions. ,
ate`: 0 -�- ) Appli n1Y
WARNING: FAILURE TO SECURE WORKV COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the ab o tion is correct.
I agree to comply with all city and county ordinances and to laws r latin to building
construction, and hereby authorize representatives of is city to a er upon the
above-mentioned property for inspection purposes. /
Date:���� Signature (Applicant or Agent
):gA: +
C_:)
ra r
N
CD
LJ1
WORKER'S COMPENSATION DECLARATION
hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
KK
provided ,for the performance
ich this pand will mnce, as required by
e Labor Cfor which this permit
kers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subjec to the workers'
compensation laws of California, and agree that, if I should beco a subject to the
workers' compensation provisions of Sectio 0 of ode, I shall forthwith
comply with those provisions. ,
ate`: 0 -�- ) Appli n1Y
WARNING: FAILURE TO SECURE WORKV COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the ab o tion is correct.
I agree to comply with all city and county ordinances and to laws r latin to building
construction, and hereby authorize representatives of is city to a er upon the
above-mentioned property for inspection purposes. /
Date:���� Signature (Applicant or Agent
):gA: +
FINANCIAL INFORMATION
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
-PAID BY
METHOD,.,
_RECEIPT #
CHECK #
CLTD BY
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA:
$1.00
$0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WALL/FENCE - FIRST 100 LF
101-0000-42404
0
$47.86
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WALL/FENCE - FIRST 100 LF PC
101-0000-42600
0
$60.91
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for FENCE OR FREESTANDING WALL:
TOTALS:••
$108.77
$0.00
00
Description: SANTERRA / LEGACY HOMES BLOCK WALL 81 LF
Type: WALL/FENCE Subtype: SPECIAL/ENGINEERED Status: APPROVED
Applied: 10/1/2015 MFA
DESIGN
Approved: 10/1/2015 MFA
Parcel No: 762500010 Site Address: 57823 BARRISTO CIR LA QUINTA,CA 92253
Subdivision: TR 32225 Block: Lot: 10
Issued:
Lot Scl Ft: 0 Building Scl Ft: 0 Zoning:
Finaled:
Valuation: $2,000.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
ADDRESSI
Details: 81LF OF 6' GARDEN WALL ON PL AT SOUTH SIDE OF PROPERTY [PROTO II SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE
COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. 2013 CALIFORNIA
BUILDING CODES.
CHRONOLOGY
CONDITIONS
CONTACTS
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
MURRIETA APARTMENT INV 37
400 E RINCON STE 105
CORONA
CA
0
CONTRACTOR
M H P BUILDERS INC
3202 WEST MARCH
LANE SUITE A
STOCKTON
CA
95219
MHURTADO@LEGACY
HOMESUSA.COM
OWNER
MURRIETA APARTMENT INV 37
400 E RINCON STE 105
CORONA
CA
0
Printed: Wednesday, October 21, 2015 2:34:10 PM 1 of 2
RMYSTEMS
DESCRIPTION
ACCOUNT
QTY-
AMOUNT
PAID
WALL/FENCE -FIRST
101-0000-42404
0
$47.86
$0.00
100 LF
WALL
/FENCE - FIRST
-F
-1
101-0000-42600
0
$60.91
$0.00
100 LF PC
Total Paid for FENCE OR FREESTANDING WALL: $108.77 $0.00
PAID DATE I RECEIPT # I CHECK # I METHOD
PAID BY CLTD
BY
ATTACHMENTS
Printed: Wednesday, October 21, 2015 2:34:10 PM 2 of 2 Cp
SYSTEMS
LEGACY HOMES SANTERRA
'I 400 E. RINCON ST., SUITE 105
\ CORONA, CALIFORNIA 92879 LA QUI NTA, CALIFORNIA'
T: 951,582.7004 F: 951.582.7003
0 TRACT: 32225 0 LH PLAN #: 3117
0 LOT #: 10 APN: 762-500-010 ® ELEV. STYLE: 'A'
0 DESCRIPTOR: PHASE 2 AI 0.17 1 9,/117 &F.
0 LOT SIZE: 9,602 S.F. * 6 LAY° F PQUINTA
0 PAD ELEV: 456.4 BUILDING & SAFETY DEPT.
• F.F. ELEV: 457.07 p.e
FOR COIF;
I DATE_
11 N00°11'45" W 90.00'
I �
N
wl
� �w
owl : =I
C�CoP
57-823 BARRISTOIRCLE
W- WATER STUB
S SEWER STUB
EIGHT
T STANDARD
TRANSFORMER
aT ABOVE GRND
TRANSFORMER
T4 UNDER GRND
FjH FIRE HYDRANT
SCALE: 1"=20'
w
S � ` N
F.
M*P �, � �4161
Bin #
City of La Quinta
2"6 80ding SL Safety Division
78-495 Calie Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address- j S 3f�R�s{�
Owner's Name: A laoi- j?LP
A. P. Number: 9 -
Address: a
Legal Description:
City, ST, Zip: �T
Contractor: ��d.•�
Telephone: D 9s/ (p zr ? rrc
Address: l (%(� �) 0[i ve' S1` ., (,�/ /
City, ST, Zip:&Y c
Telephone: Q
Project Des�cr-iption: e
L /-
State Lic. #
Arch., Engr., Designer.
Address:
City., ST, Zip:
Telephone:
:..4Ye•�i��;<r„�:�s�;;�r',;;}u�: �,•.
Construction Type: Occupancy:
Project type (circle one): Ne Add'n Alter Repair Demo
State Lic. #::
�Y{Ff¢.JNYf.'Fr ;yhr�.Cw\Yi}':•
f r;xf?;;
Name of Contact Person:
Sq. Ft.: -T—#
Stories:
# Units: 7
Telephone # of Contact Person:
Estimated Value of Project: '
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Cafes.
Reviewed, ready.for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance
Title 24 Cales.
Plans�picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2a° Review, ready for correctionslissue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"! Review, ready for correctionsfissue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees,
Total Permit Fees
r
6'_(6-0 TO V-81 PROTO II --EXPOSURE C - TRENCH FOOTING
DESIGN CRITERIA (PER 2013 CBC):
CAP BLOCK PER SHEET C 1. ALLOWABLE SOIL BEARING
PRESSURE = 1000 PSF MIN.
2. ALLOWABLE SOIL PASSIVE
PRESSURE = 150 PCF MIN.
STEEL PLATE TO BEAR FULLY 3. SEE SHEET B AND SHEET C
ON CENTER WEB OR END PRIOR TO START OF
FACE SHELL- SIZE PER CONSTRUCTION.
11 SHEET C
u
U N
Z w
W J
� O �
z w a w
N IO N
Maaa
oho
N a cn
w
aIM
S 40
THESE
oil
�1
No
,A WA
HORIZONTAL JOINT
REINFORCING TOP 2 COURSES
BELOW PLATE AND AT 24"
O.C. BELOW
POST TENSION (PT) ROD SEE
SdEET B FOR ROD SPECS -
CENTER IN WALL
PROTO II FENCE WALL
FINISHED GRADE
#4 CONTINUOUS
AT HOOK
CONTINUOUS
CONCRETE
TRENCH
FOOTING
2
1
MAX
FOR SIDEYARD RETURN WALLS
WHERE DRAINAGE SWALE
OCCURS, INSTALL DRAINAGE
BLOCK AT SWALE AT GRADE.
TRENCH DEPTH AT TOP OF 2:1 SLOPE
SETBACK - FACE OF FOOTING
TO TOP OF SLOPE
MIN. DEPTH V
TRENCH FOOTING
12" TO 36"
2'-2"
6" TO 11"
2'-7"
3" TO 5"
2'`-9"
FENCE
WALL SCHEDULE AT LEVEL SOIL
H'
MAX
DESIGN WIND
EXP MPH
PT ROD
SPACING
'D'
MIN.
JOB NUMBER
C AT 100
6'-0
C AT 110
--
--
d/1�14
C AT 120
--
--
TRACKING #
C AT 100
6'-0"
2'-2"
6'-8"
C AT 110
--
--
TMH
C AT 120
--
--
CITY OF LA QUINTA
5'-0" TO BUILDING & SAFETY DEPT.
DAYLIGHT MIN.
fesn` \ r� n
/- � 6 V D PRO. O� II STANDARD
FOR CON RUCTION LA INTA, CA
=T� t
i
DATE _ _8
JOB NUMBER
.y. 2C. SEALED ON
4-115-9155
d/1�14
TRACKING #
DRAWN
M,
0 SCOle
14-115-8964
TMH
CARUSO
:
PROTO-II TM WALL SYSTEMS
DATE
ENGR
TURLEY
-�
WWW PROT02.COM
08.19.2014
JAC
'SO �
41800 CASCADES COURT iEMECULA, CA 92591
ATTN: GARY OTTO
PACKAGE
SHEET
Q
INC.
u^
fi_
£
I PHI (951) 694-3793 - goryollo@protoii.00m I
MAY ONLY BE INSTALLED BY APPROVED AND CERTIFIED INSTALLERS
S�
J
W W W.GISO Z.COT
"iv�.n
�.�»?
.�. Bim. AND B' TNIOf POST-TEN90NED YASdIRY WALLS
•�
IONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION
OR RECORDING
UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED WTH WRITTEN SIGNATURE.
i
GENERAL STRUCTURAL NOTES
1. SOIL SHALL BE FIRM AND COMPACTED PRIOR TO PLACEMENT OF CONCRETE. PRIOR TO FOUNDATION EXCAVATION, USER SHALL
VERIFY THAT SITE SOILS CONDITIONS MEET OR EXCEED AN ALLOWABLE PASSIVE BEARING PRESSURE OF 150 PSF/FT (SOIL
CLASS 4 OR BETTER AS DEFINED BY THE CBC) STARTING AT THE TOP OF GRADE(I.E. NO TOP SOILS ARE NEGLECTED FOR
PASSIVE) AND A MINIMUM ALLOWABLE BEARING PRESSURE OF 1000 PSF.
2. FOOTINGS TO BE LEVEL. IF GROUND SLOPES THE FOOTING SHALL BE STEPPED. EACH STEP SHOULD BE PROPER HEIGHT TO
FIT BLOCK TYPE USED. ALL EXCAVATIONS SHOULD BE CLEAN AND CONTAIN NO LOOSE EARTH OR FOREIGN MATTER.
3. SEE SHEET A FOR EXPOSURE, WIND SPEED, POST TENSIONED ROD SPACING, FOOTING SIZES, ETC. USER IS RESPONSIBLE TO
VERIFY REQUIREMENTS WITH BUILDING DEPARTMENT AND OWNER. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH HE
APPROVED SITE PLAN AND APPLICABLE CODE OR JURISDICTION REQUIREMENTS.
4. SOIL BELOW FOUNDATIONS SHALL BE WELL DRAINED AND NON -EXPANSIVE. USE CONCRETE WITH A MIN. STRENGTH OF 2,500
PSI - TYPE II CEMENT (TYPE V WHERE REQUIRED BY OWNER, SOILS ENGINEER OR JURISDICTION). CONCRETE SHALL BE A MIN.
OF 48 HOURS OLD PRIOR TO FINAL TENSIONING. ALL CONCRETE SHALL BE THOROUGHLY CONSOLIDATED BY SUITABLE MEANS
DURING PLACEMENT.
5. LAP REINFORCING STEEL: LAP = 32" FOR a4 BARS IN CONCRETE.
6. CONCRETE MASONRY UNITS SHALL COMPLY WITH ASTM C-90 AND BE 2,000 PSI MIN. (F'M DESIGN CRITERIA FOR BLOCK IS
BASED ON 2000 PSI). BLOCK SHALL BE A MIN OF 7 DAYS OLD PRIOR TO ROD TENSIONING. STANDARD HEAD AND BED JOINT
BLOCKS WITH MORTAR MAY BE USED OR INTERLOCKING BLOCKS MAY BE USED. BLOCKS SHALL BE LAID IN RUNNING BOND.
7. MORTAR SHALL BE TYPE S, 2000 PSI MIN. MORTAR MUST BE A MIN. OF 4 HOURS OLD PRIOR TO INITIAL TENSIONING AND 24
HOURS OLD PRIOR TO FINAL TENSIONING.
8. FIRST MASONRY COURSE MAY BE SET IN FRESH CONCRETE FOOTING.
9. REINFORCING REBAR SHALL CONFORM TO ASTM A641; Fy = 60,000 PSI.
10. PROTO-11 HARDWARE IS DEFINED AS: TENSION RODS, BEARING PLATES, COUPLERS, NUTS, ALL THREADS, DIRECT TENSION
INDICATORS (A DIRECT TENSION INDICATOR (DTI) IS A COMPRESSIBLE WASHER) AND PLASTIC SADDLES. ALL OF THIS HARDWARE
SHALL BE SUPPLIED BY ONLY AN APPROVED PROTO-11 LICENSEE TO THE CERTIFIED INSTALLER. POST TENSION RODS SHALL BE
7/16" DIAMETER WITH 1/2" ROLL THREADS CONFORMING TO ASTM A641 (FY = 60000 PSI) AND HAVE STEEL CHEMISTRY SO
THAT BENDING AND THREADING CAN BE ACCOMPLISHED WITHOUT DAMAGE TO THE POST TENSION ROD. AREA OF POST TENSION
ROD = .1503 SQUARE INCHES. BEARING PLATES ARE 1/4" THICK (Fy=50 KSI) SEE SHEET C FOR DIMENSIONS. 1/2" COUPLERS
PER ASTM A563 GRADE A, AND THE COUPLER MUST FULLY ENGAGE THE UPPER AND LOWER ROD, FULLY ENGAGED IS DEFINED
AS 1/2" MIN. INTO COUPLER. 1/2" NUTS ARE TO BE GRADE 8, PER ASTM A325. 1/2" ALL THREADS PER ASTM A307, GRADE
60. DIRECT TENSION INDICATOR (OTI - COMPRESSIBLE WASHER) IS MANUFACTURED PER ASTM F959. PLASTIC REBAR SADDLES
ARE NON-STRUCTURAL.
11, HORIZONTAL JOINT REINFORCING SHALL BE 9 GAGE DIAMETER WIRE AND PLACED PER SHEET A AND CONFORM TO ASTM A82
LADDER TYPE, 9 GAGE DIAMETER. LAP JOINT REINFORCING ONE FULL CROSS SQUARE (6" MINIMUM LAP).
12. IN LIEU OF FULL HEIGHT RODS, CONTRACTOR MAY USE SHORTER RODS, 1/2" COUPLERS AND STRAIGHT RODS THREADED BOH
ENDS FOR ADDITIONAL LIFTS. RODS SHALL HAVE A RODS SHALL HAVE A MIN. OF 3" 'L' HOOK, WITH 1/2" NUT AT END OF
TENSION ROD WHERE EMBEDDED IN FOOTING.
13. VERTICAL CONTROL JOINTS TO BE PLACED AT MAX. 36' O.C. IN ALL NON -STUCCOED WALLS AND 20' ON CENTER IN STUCCOED
WALLS WITH CLEAN VERTICAL BREAK OF ALL MATERIALS. POST TENSION ROD SHALL OCCUR WITHIN 12" OF END OF WALL AND
12" EACH SIDE OF CONTROL JOINT.
NO COUPLERS MAY OCCUR DIRECTLY BELOW AND IN CONTACT WITH THE BEARING PLATE. NO BOND BEAM BLOCK MAY BE
USED AT PLATE/TENSION LOCATION.
TENSION RODS MAY BE STABBED INTO WET CONCRETE OR TIED IN PLACE AT CONTRACTOR OPTION.
A PROTO-11 DTI (COMPRESSIBLE WASHER) SHALL BE INSTALLED AT EVERY TENSION ROD BETWEEN THE BEARING PLATE AND
NUT WITH THE DTI "TABS" FACING UP AGAINST THE BOTTOM OF THE NUT. THE SPECIAL DEPUTY INSPECTION REQUIRED AT
TIME OF FINAL TENSIONING BY A DEPUTY INSPECTOR SHALL VERIFY FINAL TENSIONING TO 6,000 POUNDS BY 1 OF 2 METHODS;
METHOD 1; VISUAL INSPECTION OF DIRECT TENSION INDICATOR (DTI), TABS FACING UP AND COLLAPSED AGAINST NUT WITH NO
LIGHT LEAKAGE BETWEEN THE PROTO-II DTI AND BOTTOM OF NUT. METHOD 2: USE OF A CALIBRATED TORQUE WRENCH
TORQUED TO 55 FT -LBS. (DTI MUST STILL BE PLACED WITH METHOD 2. NO VISUAL INSPECTION OF DTI REQUIRED WHEN USING
METHOD 2). INSPECTOR SHALL OBSERVE THE USE OF THREAD LUBRICANT, THE POSITION OF PLATE ON BLOCK, AND INTEGRITY
OF MORTAR JOINTS, AND PROVIDE A SIGNED REPORT TO ALL REQUIRED PARTIES. PROTO II MASONRY DESIGN IS BASED ON
THIS SPECIAL INSPECTION.
POST TENSION ROD SPACING TOLERANCE IS t8" BUT HE NUMBER OF RODS FOR A GIVEN LENGTH OF WALL MUST REMAIN
THE SAME.
SEISMIC DESIGN CRITERIA: Ss=2.0 ST=0.749, SOIL CLASS= D(ASSUMED), RISK CATEGORY I.
FOUNDATION GRA
AND SIZE/DEP HPECTION PRIOR TO AND CLEANLINESS PLACEMENT OF OF FOUNDATION.ONCRETE INCLUPADO TONAL S EC�A6l NOS GTI ,�P���� UO�TA
BY JURISDICTION. � BUILDING & SAFETY DEPT.
14.
15.
16.
17
0 ES !0
O P
0 SEALED ON
w S4 5 m
d ;o CARUSO 8
TURLEY
JJ �'l RUCTVR �`r IbI.
SCOTT
` gTFOF CA1�Fwww ccttsoz.com M
APPROVED
FOR CONSTRUCTIOI
DATE _ b44_
SC01
PROTO-II TM WALL SYSTEMS
WWW.PROT02.COM
41800 CASCADES COURT TEMECULA. CA 92591
ATTN: GARY OTTO
PH# (951) 694-3793 - goryollo®proloiicam
(MAY ONLY BE INSTALLED BY APPROVED AND CERTIFIED INSTALLERS)
4-_ 6'_ AND 6' Mlbc POST-TEN90NEO MASONRY WALLS
II STANDARD
JTA, CA
B NUMBER
—i' -115-9155
TRACKING #
DRAWN
14-115-8964
TMH .
DATE
ENGR
08.19.2014
JAC
PACKAGE
SHEET
S1.1
B
_l THESE DRAWINGS/CALCULATIONS ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION DR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORD'S SEAL IS AFFIXED WITH WRITTEN SIGNATURE.
TOP OF PROTO II WALL
rl
(3)
(4)
0
I
x SECTION
(8)
(7)
A. PROTO II DTI TO BE USED AT EACH TENSION ROD.
TABS FOR DTI SHOULD FACE UP AGAINST BOTTOM
OF NUT. TABS WILL COLLAPSE (NO LIGHT PASSES
BETWEEN BOTTOM OF NUT AND DTI) WHEN PROPER
TORQUE OF NUT HAS BEEN ACHIEVED.
B. AS ALTERNATE TO VISUAL INSPECTION OF TABS,
INSPECTION OF NUT TORQUE MAY BE ACHIEVED BY
USE OF A CALIBRATED TORQUE WRENCH. TORQUE
NUTS TO 55 FT -LBS. DTI STILL MUST BE PLACED ON
ROD IF USING TORQUE WRENCH METHOD. SEE
GENERAL NOTE ON SHEET B.
C. SPECIAL DEPUTY INSPECTOR WILL PERFORM A
VISUAL INSPECTION WHEN USING THE DTI METHOD TO
CONFIRM THE DTI IS COLLAPSED WITH NO LIGHT
LEAKS BETWEEN THE TABS AND BOTTOM OF NUT.
IF USING TORQUE WRENCH METHOD, DEPUTY
INSPECTOR WILL CONFIRM WALL IS TORQUED TO 55
FT -LBS. NO VISUAL INSPECTION OF DTI IS REQUIRED.
D. INSTALLER MUST HAVE SPECIAL DEPUTY INSPECTION
OF TENSIONING PERFORMED BY ONE OF THE TWO
METHODS NOTED ABOVE. SPECIAL DEPUTY INSPECTOR
TO PROVIDE A COMPLETED REPORT TO LISTED
PARTIES.
ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORDS SEAL IS AFFIXEDNTH WRITTEN SIGNATURE.
KEY NOTES:
1.
POST TENSION ROD.
2,
NUT.
3.
DIRECT TENSION INDICATOR (DTI).
4.
BEARING TOP PLATE.
5.
COLLAPSIBLE TABS.
6.
MINIMUM TENSION TO BE 6,000 LBS LOAD AND
CONFIRMED BY ONE OF TWO METHODS PER
NOTES "B" & "C" BELOW.
7.
FILL CAP BLOCK WITH MORTAR. IMMEDIATELY
"FLIP" ONTO ROD. COMPLETELY COVER NUT, ROD
AND PLATE WITH MORTAR.
(5)
8.
CAP BLOCK OF SUFFICIENT SIZE TO COVER
PLATE AND ROD.
9.
CONTINUOUS HORIZONTAL JOINT REINFORCING.
10.
CENTER WEB OR END FACE SHELL BELOW.
11.
STEEL PLATE SIZES:
A. 4" PROTO IT:1/4%Yx6"
(�)
B. 4" SLUMP PROTO 11:1/4"x2 1/2°x6"
(z)
C. 6" PROTO 11:1/4"x4 1/2"x6"
D. 6" SLUMP PROTO 11:1/4"x4"x6"
STEEL PLATES TO BE PLACED AT THE EDGE OF
THE CELL SO THAT THE PLATE BEARS FULLY ON
THREE SIDES.
12.
DO NOT USE BOND BEAM BLOCK AT BEARING
PLATE LOCATIONS.
A. PROTO II DTI TO BE USED AT EACH TENSION ROD.
TABS FOR DTI SHOULD FACE UP AGAINST BOTTOM
OF NUT. TABS WILL COLLAPSE (NO LIGHT PASSES
BETWEEN BOTTOM OF NUT AND DTI) WHEN PROPER
TORQUE OF NUT HAS BEEN ACHIEVED.
B. AS ALTERNATE TO VISUAL INSPECTION OF TABS,
INSPECTION OF NUT TORQUE MAY BE ACHIEVED BY
USE OF A CALIBRATED TORQUE WRENCH. TORQUE
NUTS TO 55 FT -LBS. DTI STILL MUST BE PLACED ON
ROD IF USING TORQUE WRENCH METHOD. SEE
GENERAL NOTE ON SHEET B.
C. SPECIAL DEPUTY INSPECTOR WILL PERFORM A
VISUAL INSPECTION WHEN USING THE DTI METHOD TO
CONFIRM THE DTI IS COLLAPSED WITH NO LIGHT
LEAKS BETWEEN THE TABS AND BOTTOM OF NUT.
IF USING TORQUE WRENCH METHOD, DEPUTY
INSPECTOR WILL CONFIRM WALL IS TORQUED TO 55
FT -LBS. NO VISUAL INSPECTION OF DTI IS REQUIRED.
D. INSTALLER MUST HAVE SPECIAL DEPUTY INSPECTION
OF TENSIONING PERFORMED BY ONE OF THE TWO
METHODS NOTED ABOVE. SPECIAL DEPUTY INSPECTOR
TO PROVIDE A COMPLETED REPORT TO LISTED
PARTIES.
ARE CONSIDERED PRELIMINARY -NOT FOR CONSTRUCTION OR RECORDING UNLESS THE STRUCTURAL ENGINEER OF RECORDS SEAL IS AFFIXEDNTH WRITTEN SIGNATURE.