Loading...
BRES2015-038878-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: LUCAS CORONEL 48820 EISENHOWER DR LA QUINTA, CA 92253 Tir4lw4" COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT BRES2015-0388 52731 AVENIDA BERMUDAS 773305024 LOPEZ / PATIO COVER REPLACE WINDOWS RESTUCCO HOUSE $10,000.00 DEC 28 2015 CITYOFLAQUIUTA COMi1iUNITY DE'IELOP:L1CPIT DEPARTt"TIENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: _ License No.::SKH:1510061027531372 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant. for a permit subjects the applicant to a civil penalty of.not more than five hundred dollars \($500).: (�lJfa's owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered fo'r sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees; provided that the improvements are not intended or offered for sale: If, however, the building or improvement is sold within one year.of completion, the owner -builder will have the burden of proving that Tr she did not build or improve for the purpose of sale.j. I, aspwner of the property, am exclusively contracting with licensed contractors n uct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to qbe Contractors' State License Law.). ( -) Ijam exempt under Sec. B.&P.� for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: 11111111111111111111 05 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 12/28/2015 Owner: LOPEZ ELEUTERIO P ESTATE OF Contractor: LOPEZ ELEUTERIO P ESTATE OF 49608 ESCALANTE ST INDIO, CA 92253 Llc. No.::SKH:1510061027531372 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Polity Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to'become subject to the workers' compensation laws of California, and agree that, if l should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100;000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this. application: 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby ayuthorize representatives of this city to enter upon the above-menYofor inspection purposes. �. Date: Signature (Applicant or Agen FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY LUCAS CORONEL CHECK R11784 2715. SGU Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00 DESCRIPTION ACCOUNT QTY. AMOUNT PAID PAID DATE PATIO COVER, STD, OPEN 101-0000-42404 0 $97.17 $97.17 12/28/15 PAID BY METHOD..:. ` RECEIPT-# •, CHECK # CLTD BY - LUCAS CORONEL CHECK R11784 2715 SGU DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PATIO COVER, STD, OPEN PC 101-0000-42600 0 $95.72 $95.72 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY LUCAS CORONEL CHECK R11784 2715 SGU Total Paid for PATIO COVER / COVERED PORCH / LATTICE: $192.89 $192.89 DESCRIPTION ACCOUNT ;' .' QTY AMOUNT ;. PAID PAID DATE SMI - RESIDENTIAL 101-0000-20308 0 $1.30 $1.30 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY LUCAS CORONEL CHECK R11784 2715 SGU Total Paid'for STRONG MOTION INSTRUMENTATION SMI: $1.30 $1.30 DESCRIPTION - ACCOUNT; QTY AMOUNT PAID PAID'DAT£ STUCCO APPLICATION,, EA ADDITIONAL 500 SF 101-0000-42404 0 $14.50 $14.50 12/28/15 PAID BY METHOD RECEIPT # CHECK # '. CLTD BY LUCAS CORONEL CHECK R11784 2715 SGU DESCRIPTION ACCOUNT QTY AMOUNT � PAID PAID DATE, STUCCO APPLICATION,. FIRST 500 SF 101-0000-42404 0 ..$24.66 $24.66 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY LUCAS CORONEL CHECK R11784 2715 SGU DESCRIPTION ACCOUNT QTY-: AMOUNT PAID PAID DATE STUCCO APPLICATION, FIRST 500 SF PC 101-0000-42600 0 $73.97. $73.97 12/28/15 .PAID BY METHOD" . RECEIPT # `: .. CHECK # "CLTD BY ` LUCAS CORONEL CHECK R11784 2715 SGU Total Paid for STUCCO APPLICATION: $113.13 $113.13 DESCRIPTION ACCOUNTQTY. AMOUNT . PAID PAID DATE, DOOR/WINDOW, REPLACE FIRST 7 101-0000-42400 0 $60.91 $60.91 12/28/15 PAID BY METHOD 'RECEIPT # CHECK # CLTD BY LUCAS CORONEL CHECK R11784 2715 SGU DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DOOR/WINDOW, REPLACE, EA ADDITION 5 101-0000-42400. 0 $10.15 $10AS 12/28/15 PAID BY METHOD _. RECEIPT # CHECK # CLTD BY LUCAS CORONEL CHECK R11784 2715 SGU r DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DOOR/WINDOW, REPLACE, EA ADDITIONS PC 101=0000-42600 0 $11.60 $11.60 ' 12/28/15 PAID BY ;. METHOD RECEIPT # CHECK # CLTD BY LUCAS CORONEL CHECK R11784 2715 SGU DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DOOR/WINDOW, REPLACE, FIRST 7 PC 101-0000-42600 0 -$110.22 $110.22 12/28/15 PAID BY METHOD RECEIPT # . CHECK # CLTD BY LUCAS CORONEL CHECK R11784 2715 SGU Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $192.88 $192.88 TOTALS:• Description: LOPEZ / PATIO COVER REPLACE WINDOWS RESTUCCO HOUSE Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: APPROVED Applied: 10/6/2015 SGU Approved: 12/28/2015 JJO Parcel No: 773305024 Site Address: 52731 AVENIDA BERMUDAS LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 140 Lot: 11 Issued: UNIT 15 CHRONOLOGY TYPE Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $10,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 STEPHANIE GUMPERT Details: REPAIR AND REMODEL EXISTING 275 SQ. FT. PATIO PER CITY SPECS, REPLACE WINDOW AND DOORS ANDRE STUCCO HOUSE. Printed: Monday, December 28, 2015 9:32:22 AM 1 of 3 CN SYS7Eti1S ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES PLAN CHECK PICKED UP STEPHANIE GUMPERT 10/26/2015 10/26/2015 PICKED UP BY LUCAS PLAN CHECK SUBMITTAL RECEIVED STEPHANIE GUMPERT 10/6/2015 10/6/2015 PLAN CHECK SUBMITTAL RECEIVED STEPHANIE GUMPERT 12/17/2015 12/17/2015 TELEPHONE CALL JIM JOHNSON 10/8/2015 10/8/2015 CALLED LUCAS CORONEL TO INFORM HIM THE PLANS ARE READY CORRECTIONS TELEPHONE CALL JIM JOHNSON 12/28/2015 12/28/2015 CALLED OWNER TO INFORM HIM PLANS ARE READY TO ISSUE. CONDITIONS Printed: Monday, December 28, 2015 9:32:22 AM 1 of 3 CN SYS7Eti1S FINANCIAL •' • .DESCRIPTION ACCOUNT . QTY AMOUNT PAID CONTACTS BY NAME TYPE NAME ADDRESSI CITY . STATE ZIP PHONE FAX EMAIL APPLICANT LUCAS CORONEL 48820 EISENHOWER DR LA QUINTA CA 92253 CONTRACTOR LOPEZ ELEUTERIO P ESTATE OF 49608 ESCALANTE ST INDIO CA 92253 OWNER LOPEZ ELEUTERIO P ESTATE OF 49608 ESCALANTE ST INDIO CA 92253 FINANCIAL •' • .DESCRIPTION ACCOUNT . QTY AMOUNT PAID PAID DATE RECEIPT. CHECK q, METHOD PAID BY CLTD !# BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 12/28/15 R11784 2715 CHECK LUCAS. CORONEL SGU Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: PATIO COVER, STD, 101-0000-42404 0 : $97.17 $97.17 12/28/15 R11784 2715. CHECK LUCAS CORONEL SGU OPEN PATIO COVER, STD, 101-0000-42606 0 $95.72 $95.72 12/28/15 R11784 2715 CHECK LUCAS CORONEL SGU OPEN PC Total Paid for PATIO COVER / COVERED PORCH / LATTICE: $192.89 $192.89 SMI -RESIDENTIAL 101-0000-20308 0 $1.30 $1.30 12/28/15 R11784 2715 CHECK LUCAS CORONEL SGU, Total Paid for STRONG. MOTION INSTRUMENTATION SMI: $1.30 $1.30 STUCCO APPLICATION, 101-0000-42404 0 $14.50 $14.50 12/18/15 R11784 2715 CHECK LUCAS CORONEL SGU EA ADDITIONAL 500 SF STUCCO APPLICATION, 101-0000-42404 '0 $24.66 $24.66 12/28/15 R11784 2715 CHECK LUCAS CORONEL SGU FIRST 500 SF STUCCO APPLICATION, 101-0000-42600 0 $73.97 $73.97 12/28/15 R11784 2715 CHECK LUCAS CORONEL SGU FIRST 500 SF PC Total Paid for STUCCO APP LICATION:• $113.13 $113.13 DOOR/WINDOW, 101-0000-42400 0 $60.91 $60.91 12/28/15 R11784 2715 CHECK LUCAS CORONEL SGU REPLACE FIRST 7 DOOR/WINDOW, REPLACE, EA ADDITION 101-0000-42400 .0 $10.15 $10.15 12/28/15 R11784 2715 CHECK LUCAS CORONEL SGU 5 Printed: Monday, December 28, 2015 9:32:22 AM 2 of 3 C9? SYSTEMS tT .• Permit Details PERMIT NUMBER City of La Quinta BRES2015=0388 INSPECTIONS PARENT PROJECTS INFORMATION OWNER DESCRIPTION ATTACHMENTS REVIEWS DOC 10/8/2015 REVIEW TYPE REVIEWER CLTD DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST BLDG NS (1 WK) JIM JOHNSON 10/6/2015 10/13/2015 DESCRIPTION ACCOUNT, .. .. QTY AMOUNT • PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY - BY DOOR/WINDOW; REPLACE; EA ADDITION 101-0000-42600 0 $11.60 $11.60 12/28/15 R11784 2715 CHECK LUCAS CORONEL SGU 5 PC DOOR/WINDOW, 101-0000-42600 0 $110.22 $110.22 12/28/15 R11784 2715 CHECK LUCAS CORONEL SGU REPLACE, FIRST 7 PC Total Paid for WINDOW/SLIDING GLASS $192.88 $192.88 ' DOOR/FENESTRATION:. INSPECTIONS PARENT PROJECTS BOND INFORMATION OWNER DESCRIPTION ATTACHMENTS REVIEWS DOC 10/8/2015 REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST BLDG NS (1 WK) JIM JOHNSON 10/6/2015 10/13/2015 10/8/2015 REVISIONS REQUIRED 2ND BLDG NS (1 WK) JIM JOHNSON 12/17/2015 12/28/2015 12/28/2015 APPROVED BOND INFORMATION OWNER DESCRIPTION ATTACHMENTS SUBDIR ETRAKIT ENABLED DOC 10/8/2015 JIM JOHNSON BRES2015-0388.docx Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/8/2015 JIM JOHNSON BRES2015-0388.docx BRES2015-0388.docx 0 Printed: Monday, December 28, 2015 9:32:22 AM 3 of 3 SYSTEMS 5 Bin City of La Quin to Building 8i' Safety Division Permit #1 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: Owner's Name: 4U/ S GZ A. ber: 773— 30.5— �� Address: Legal Description: [ dXJ—le— "I V City, ST, Zip: � Contractor: r . Telephone: � ............ Address: Vii) Project Description: City, ST, Zip: �(f oLe e, 1 Nre d,) Telephone: w/ 9" — � n t; e� CX S /t State Lic. 1,4J City Lic. #; Designer: u e Address: ��Zv City., ST, Zip: hone: Zd Occupancy: �ConstruTele ancY(� cti n TYPe• t� Lic. #: - New wAdd'n Alter Repairair Demo Project type Name of Contact Person: U Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cafes. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance. Title 24 Calcs. Plans picked up Construction . Flood plain plan Plans resubmitted Mechanical Grading plan 2"" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. Ii.O.A. Approval Plans resubmitted Grading IN HOUSE:- 'rd Reyiew, ready for corrections/issue Developer Impact Fee Planning Approval' Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, Total Permit Fees ,CZ Td -f 44Q" COMMUNITY DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 (760) 777-7125 FAX (760) 777-7011 RESIDENTIAL PLAN CHECK CORRECTION LIST (os) DATE: 10/8/2015 STATUS: FIRST REVIEW PLAN CHECKED BY: JIM JOHNSON TELEPHONE NUMBER: (760) 777-7130 ADDRESS: 52-731 AVE BERMUDAS DESCRIPTION: REMODEL APPLICANT: LOPEZ PLAN CHECK #: BRES2015-0388 This submittal has been checked for compliance with the 2013 California Residential, Mechanical, Electrical, Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code. APPLICANT: BUILDING DEPARTMENT STAFF: The following items are being returned to you for DO NOT accept any resubmittal unless ALL of the correction: following items are included: 1 SET OF PLANS 1 SETS TITLE -24 1 SET CITY SPEC, PATIO THIS CORRECTION LIST REDLINED SET 2 NEW REVISED SETS 1 ASSESSORS SET 2 SETS TITLE -24 2 CITY SPECS ( PATIO DETAILS) THIS CORRECTION LIST / RESPONSES INSTRUCTIONS TO APPLICANT: 1) Provide a written response'to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A=3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List Page] of 2 SECTION A - GENERAL 1) Provide the Assessor's Parcel Number (APN) and complete legal description of Project on the first sheet of Plans. LOT 11, APN # 773-305-024 2) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and telephone number and wet -signature. If the preparer is a licensed architect or -engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code §5536. Resubmittals will not be accepted -with signatures missing. 3) Note on Plans: "All construction shall comply with the 2013 California Residential, Mechanical, Electrical, Plumbing, Energy, and Green Building Codes and the La Quinta Municipal Code." Remove notes referencing other Codes. SECTION C - ARCHITECTURAL 1) Show on Floor Plan or Window Schedule all locations of windows requiring safety glazing. (CRC §R308.4) See Floor Plan for area(s) SECTION K - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. 2) Provide one copy each of the Site Plan and Floor Plan for the County Assessor's office. While not required for resubmittal, this administrative item must be addressed prior to issuance of building permit. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List Page 2 of 2 BUILDING & SAFETY DEPARTMENT 78-495 CALLE TAMPICO (760) 777-7012 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 Considering Becoming an Owner -Builder? Important information you need to know BEFORE pulling your permit! The term "Owner -Builder" can mean three different things: "Owner as Worker", "Owner as Contractor" or "Owner as Employer" Understand each has Benefits or Risk, and it is possible to combine them! Hiring a California Licensed Contractor means you do not personally perform any of the construction work, the permit is not taken out in your name, you are not personally responsible for the construction and you are not an Owner -Builder. Instead, you become a "Cusfomer" and California law provides you the benefit of protection from poor workmanship, failure to finish the job and financial risk due to worker injury. Benefit/Risk: Highest Benefits and the Least amount of Risk Owner -as -Worker is a type of Owner -Builder where you personally perform the construction. work, the permit is taken out in your name and you are personally responsible for the construction management, knowledge, workmanship, and completion of the job. You benefit by not paying others to perform this work for you and your risk depends on your own ability to complete the job successfully. Benefit/Risk: Possible Benefit with Low Financial Risk Owner -as -Contractor is a type of Owner -Builder where you personally act as your own General Contractor, the permit is taken out in your name and you hire California licensed sub -contractors to perform portions of the construction work. WARNING: The benefit of protection provided by law when you hire only California licensed sub -contractors can turn to serious financial risk if you hire unlicensed contractors to perform any of the work. Benefit/Risk: Possible Benefit and Significant Financial Risk Owner -as -Employer is a type of.Owner-Builder where you pay any unlicensed individual to perform any construction work valued at more than $500.00, the permit is taken .out in your name and you are. personally responsible for their employment requirements, supervision, performance, safety and welfare while on your property. WARNING: Cost savings benefit can turn'to serious financial risk if you fail to deduct payroll taxes or provide workers compensation insurance for each worker. Benefit/Risk: Possible Benefit with Significant Financial Risk (Health and Safety Code Section 19827) The California Legislature declares an "urgent and statewide public interest in assuring" that contractors comply with Contractors' License Law, Business and Professions Code and Workers' Compensation Insurance requirements to ensure property owners are informed about, and protected from the following when. improving their property as Owner -Builders: Fraudulent representations - Liability for worker's injuries • Liability for material and labor costs unpaid by contractors • Licensing requirements - Employers tax liabilities Over 20,000 consumer complaints are filed each year. Many complaints relate to owner/builder projects and include workmanship and workers' compensation issues Homeowners suffer financial harm due to defective workmanship and injured employees. Following are alarming examples of what has occurred with Owner -Builder permits: Example 1: Homeowner received insurance money to rebuild burned -down home. ■ Owner/Builder permit pulled to rebuild structure. ■ Unlicensed contractor built substandard structure — must be torn down and replaced. ■ Estimated financial injury is $225,000. ■ Additional financial injury - IRS threatened to tax insurance payout if house not completed by the end of the year. Example 2: Brother-in-law had active license but fled an exemption from Workers Comp.. • Owner -Builder hires brother-in-law to install a new roof. ■ .Employee falls and sustains multiple spinal and extremity fractures as well as ahead injury and remains in a coma to this day. ■ The Owner -Builder, who has sold the home, is now a defendant.in a lawsuit for reimbursement for benefits paid to the injured worker. Example 3: Employee of contractor without Workers Comp is hired by Owner -Builder to install septic system and suffers injury that results in permanent disability. • The Owner -Builder did not have a homeowner's insurance policy on the house against which to submit a claim. ■ The Owner -Builder is now a defendant in a lawsuit for reimbursement for benefits paid to the injured worker. Did you know — unlicensed persons frequently have the property owner obtain an "Owner -Builder" building permit which erroneously implies that the property owner is providing his or her own labor and material personally? Did you know — your homeowner's insurance may not provide coverage for injuries sustained on your property by an unlicensed contractor and his/her employees? Did you know — if you are considered an "employer" under state and federal law, you must. register with the state and federal government, withhold payroll taxes, provide workers compensation and disability insurance and contribute to unemployment compensation for each "employee"? Did you know — that if you fail to abide by these laws you may be subjected to serious financial risk?. OWNERS BEWARE AND CONSIDER THE RISK BEFORE ACCEPTING FULL RESPONSIBILITY FOR YOUR CONSTRUCTION PERMIT Tdf 4 4 QUM& P.D. Box 1504 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLS TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT PROPERTY OWNER'S PACKAGE (760)777-7012 FAX (760) 777-7011 Disclosures & Forms for Owner -Builders Applying for Construction Permits IMPORTANT! NOTICE TO PROPERTY OWNER Dear Property Owner: An application for a Building permit has bf en submitted in your name listing yourself as. the builder of the property improvements specified at 5'"Z 1 3C r+ "t_ &-eV 'vas L- We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION DIRECTIONS: Read and initial each statement below. to signify you understand or verify this information. ��derstand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder" flgmit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my p e d building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. C �3. I understand as an "Owner -Builder" I am the responsible party of record on the permit I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of rriy own. 4. I un rstand Contractors are required by law to be licensed and bonded in California and to list their license numbers on is anpgontracts. un erstand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" der state and federal law.64::��un- derstand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to.serious financial ris . Q4J_Iunderstand under California Contractors' State License Law, an Owner-Builder.who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. �. I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. Z I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Cervice, the United States Small.Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1- 800-32 1 -CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. 1 am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the party legally: and financially responsible ' for proposed construction' activity at the following address: gree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner -Builders asmell as employers. agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with -any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be .in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuingAe permit. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable to t e gency is required to b esented when the permit is issued to verify the property owner's signature. Signature of property owner Date: 0 Note: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agents) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. a i Past, Scope of Construction Project (or Description of Work): K,D ll , P, �ti� c��S _ I�z Lj-t I �( e�—� i,, S �--X31 -c_ . _ \ Project Location or Address: _/ v cQr,� : . si CdI— Name of Authorized Agent: Address of Authorized Agent: Tel Noom I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accurac r Note. -,4 copy of the owne ' driver's license, form notarization, or other verification acceptable to the agency is requi a to be presented when t permit is issued to verify the property ow er s signature. Property Owner's Signature: Date: RATER SIZE Am SPACr1C SPEOFY ROOFING AlO SNEAD"NC OR OPEN lAR1,'•T --� ZL.t 1(----- oF (SEE Ro�N =EVE NOTE ON RRSE) -- / Roof MCN (SAW SCE -AS wn:pM HCAMpI S= -q �� _- s2 y it iFTER SPEW: . fit 2000 P.s.I co"cnm —»: " i nmm 1 L_J a" LATTICE PAhO COVERS NAY 6E ATTACHED T MA ONE 114' r S MI LAC SCREW TOIJCM MO EACH `RA TER TML_ 1/6- • S' LAC SCREWS MO STUDS AT 16. O.C. r Oumwous t.Epco i X If Fonda ''rid 7:00 a.. 5:3 ,�tv day: 00 a.m. to 5: uciday: Govprpment Colc ffil!,days: None =r ►w mR OR i4xFe1�C,Q,C IE'Iav 1 s - S-n�cmber (OiH Saturday: 8:00 a.m. to 5:00 P.M. Sunday: None DEPARTMENT APPROVAL BELOW RE @1 i`� QvIn, COLING & S TA D C 1 7APPR V� �EpT CI OF LA S JI I�TRNST CTION COMM NITY DEVELOPMENT , / (FFIC� [cop� 'r AM V STRAPS . Ill (t) 164 ►w1S OR 8011 POST-S1'A0Ww--�! _ POSM; yyo `_L- -- Wt train notwc 1 <' . tr BEL M' ORA,DE L _ J PROV0E t C1 EAR NCE BETWEEN POST AM CONCRETE Lt1rJO ill.t t7P1 4`=1 OIL Aar$ag Ca°dgoii New Year's Dr. Martin Lu President's Day °RMpendence Day I ab�nrDay u-sWerwk &ILE = 0R %rTstmas Day PRO"X T' CLEARANCE BETWEEN POST MD ANCHOR BOLT (EMBED — T MIN. INTO CONCRETE) . TYPICAL PATIO COYER DATE Of APPLCAT*N ,S OWNER'S NAME G� STREET AOOREss5Z-7. A,, e P,,v� Mr. ST ZIP vi TELEPHONE '� I 39Q�r jz �f 1 SA mcso 2000 P.s.I co"cnm —»: " i nmm 1 L_J a" LATTICE PAhO COVERS NAY 6E ATTACHED T MA ONE 114' r S MI LAC SCREW TOIJCM MO EACH `RA TER TML_ 1/6- • S' LAC SCREWS MO STUDS AT 16. O.C. r Oumwous t.Epco i X If Fonda ''rid 7:00 a.. 5:3 ,�tv day: 00 a.m. to 5: uciday: Govprpment Colc ffil!,days: None =r ►w mR OR i4xFe1�C,Q,C IE'Iav 1 s - S-n�cmber (OiH Saturday: 8:00 a.m. to 5:00 P.M. Sunday: None DEPARTMENT APPROVAL BELOW RE @1 i`� QvIn, COLING & S TA D C 1 7APPR V� �EpT CI OF LA S JI I�TRNST CTION COMM NITY DEVELOPMENT , / (FFIC� [cop� 'r AM V STRAPS . Ill (t) 164 ►w1S OR 8011 POST-S1'A0Ww--�! _ POSM; yyo `_L- -- Wt train notwc 1 <' . tr BEL M' ORA,DE L _ J PROV0E t C1 EAR NCE BETWEEN POST AM CONCRETE Lt1rJO ill.t t7P1 4`=1 OIL Aar$ag Ca°dgoii New Year's Dr. Martin Lu President's Day °RMpendence Day I ab�nrDay u-sWerwk &ILE = 0R %rTstmas Day PRO"X T' CLEARANCE BETWEEN POST MD ANCHOR BOLT (EMBED — T MIN. INTO CONCRETE) . TYPICAL PATIO COYER DATE Of APPLCAT*N ,S OWNER'S NAME G� STREET AOOREss5Z-7. A,, e P,,v� Mr. ST ZIP vi TELEPHONE '� I 39Q�r jz � 1Y NOTES: 1. 32' RAFTER SPACING IS ALLOWABLE FOR OPEN LATTICE PATIO COVERS ONLY. 2. FOR SOLID. PATIO COVERS (NOT LATTICE) RAFTER "PAN IS LIMITED TO. 10'-0' USING . THIS STANDARD, LATTICE ROOF BUILT—UP ROOF HEADERS HEADERS DOUGLAS FIR NO. 1 DOUGLAS FIR NO. 1 ALL CONSTRUCTION SHALL CONFOR TO THE PROVISIONS OF THE .. SIZE SPAN 1. SIZESpgN I ROOFING NOTES: 27S 59 c"r 4x4 3'=0" 4x4 A. BUILT—UP. ROLLED ROOF: SLOPE TO DRAIN. 4x6 8'—O' 4z6 _ 6•_0 4x8 1 1'—p 4x8 8. :ROCK ROOF: 3/12 MAXIMUM PITCH. 4x10 14'-0 4x10_ 4x`12 17'—p 4x12 6x8 14'=p" 6x8 1 -9:1 . 6x10 17'—p. —6x10 14' RAFTER SPAN TABLE : � .� ' ' i: GRADING RULES PS 20-70 _c� C-7 FEET & INCHES 2x4 16' O.C. 1 — g _� �•_ :R:_4- 24 2x6 16' O.C. 24 24 16' O.C. IF 24" �- ' ='— i JL -0' ;13'-0`. NOTES: 1. 32' RAFTER SPACING IS ALLOWABLE FOR OPEN LATTICE PATIO COVERS ONLY. 2. FOR SOLID. PATIO COVERS (NOT LATTICE) RAFTER "PAN IS LIMITED TO. 10'-0' USING . THIS STANDARD, LATTICE ROOF BUILT—UP ROOF HEADERS HEADERS DOUGLAS FIR NO. 1 DOUGLAS FIR NO. 1 ALL CONSTRUCTION SHALL CONFOR TO THE PROVISIONS OF THE .. SIZE SPAN 1. SIZESpgN I ROOFING NOTES: 27S 59 c"r 4x4 3'=0" 4x4 A. BUILT—UP. ROLLED ROOF: SLOPE TO DRAIN. 4x6 8'—O' 4z6 _ 6•_0 4x8 1 1'—p 4x8 8. :ROCK ROOF: 3/12 MAXIMUM PITCH. 4x10 14'-0 4x10_ 4x`12 17'—p 4x12 6x8 14'=p" 6x8 1 -9:1 . 6x10 17'—p. —6x10 14' 1�1 55 x 25.5 f1h. C> - b N A W e 24 x STATE OF CALIFORNIA RESIDENTIAL ALTERATIONS CEC-CFIR-ALT-01-E Revised 06/14 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ALT-01-E Prescriptive Residential Alterations (Page 1 of 4) Project Name: Date Prepared: A. GENERAL INFORMATION 01 02 01 Project Name: ,572— 3 _ e/ 02 Date Prepared: 03 Project Location: 197 457S04 Building Front Orieritation(deg or cardinal): 05 CA City: 06 Number of Altered proielling Units: ' 07 Zip Code: 08 Fuel Typg: J(� 09 Climate Zone: 10 Total Conditioned Floor Area 104:1 11 Building Type 12 51ab,Area'(ft2) L.1= 13 Project Scope: 4eck� ik. ' I& N- I M L 1 r-% \ I I B. BUILDING INSULATION DETAILS (Section 150.2(b)1) � w 01 02 03 04 05 06 e--,'$," 07 I 081H" 99 10 1 Tag/ID Assembly Type Frame Type Frame Depth (inches) fProposed 41- t\"" A o , Appendix JA4 Frame Continuous Reference Spacing Cavityi Insulation NI (inches) R -value R -value a� 3 U f 2tor Table. Cell Required `5 W /� C/) m Li 0.'S i Z ®� r t( z' ��im;rraent LI -Factor Initial Solar Aged Solar Thermal SRI Aged Solar Thermal SRI Method of Roof X. 4eck� Compliance Pitch Exception i; r NumXodutt roduct Type _ ,In ulation Reflectance Reflectance Emittance (Optional) Reflectance Emittance (Optional) UJ I C. ROOF REPLACEMENT (Prescriptive Alteration, S oA'A-S0.2(b)1H),\� 1* 1a J 01 02 03 04 9N: 05\ 06 ti�' °0.7�` 08 09 10. 11 12 13 * U R value vo Proposed Minimum Required Initial Solar Aged Solar Thermal SRI Aged Solar Thermal SRI Method of Roof CRRC R.cD Iber 4eck� Compliance Pitch Exception i; r NumXodutt roduct Type _ ,In ulation Reflectance Reflectance Emittance (Optional) Reflectance Emittance (Optional) 'N o� NOTESRoof area covered by, buildigg_integrate�d� photovoltaic panels and solar therms panels are exempt from the above Cool Roof requirements. • Liquid field coat ngs5must stallation applied comply with, ni criteria from section 110.8(1)4. ti. C � F ! N�- - Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance DEC 17 2015 CITY OF LA QUINTA COMMUNITY DEVELOPMENT HERS Provider: June 2014 J/ STATE OF CALIFORNIA RESIDENTIAL ALTERATIONS CEC-CFIR-ALT-01-E Revised 06114 CALIFORNIA ENERGY COMMISSION I Am CERTIFICATE OF COMPLIANCE CF111-ALT-01-E Prescriptive Residential Alterations (Page 2 of 4) Project Name: Date Prepared: D. FENESTRATION/GLAZING AREAS ALLOWED (Section 150.2(b)1) 04--, " 01 02 03 Alteration Type Orientation Maximum Allowed ft2 COMme fs .-NIX ON� E. FENESTRATION/GLAZING PROPOSED AREAS AND EFFICIENCIES (Section 150.2(b)1)� 01 02 03 04 05 06 07 08 Ae 4t 09 10' > 11 12 13 14 15 Combined Tag/ Fenestration Frame Dynamic Orientation N, 5, W, E, or Area Removed Area � Added NYet Added Maximumk Allowed * Exterior Shading SHGC from ID Type Type Glazing Roof ft2 ft2 Area ft2 U factor U -factor Source SHGC Source Device CFIR ENV 03 Al o 't, n ..... a Net Added Wes nestration '2 ,f.ah �A�ea ;� ` b Existing + Added W�est',fa ing Fene�stratlo U.,rea c Maximum �lfdwedd West -facing= s str'ation Area, d Is West -facing Fenestration Area,,< Maximum Allowed Wesi--'facing Fenestration C,. Ar'rea,, e Net Added fen}estraion Area (all oien'tations) f Existing +Added;F stration Area (all"of en�tations) g t� ns) 40% MaximumrA lowed Fenestration Area (all orientations) Is Existing + gild%ed Fenestration Area < Maximum Allowed Fenestration Area (all ( orientations) Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 STATE OF CALIFORNIA RESIDENTIAL ALTERATIONS CEC-CFIR-ALT-01-E Revised 06/14 CERTIFICATE OF COMPLIANCE j Prescriptive Residential Alterations Proiect Name: Date IM CF1R-ALT-01-E (Page 4 of 41 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: -.'Ak Company: Signature Date: $. "Y 9Z . " Address: CEA/ HERS Certification Ide tlric ition'(if applicable l: City/State/Zip: Phone:, x-. _ 1. RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: V 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building de n or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured66&sfor the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the Cal p q I ornia Code oftiZegulations. 4. The building design features or system design features identified on thisCertificate of Compliance are consister. itt the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted:to the enforcement a eri ='for 'm p p g cy, pproval with this building permit application. i` `la 5. 1 will ensure that a registered co h `' g copy of this Certificate of Complianeeashall be made available with the building permits) issued for the building, and made available to the enforcement agency for all applicable inspections. 1 that C Mato understand a registered copy of this of mpliance isir be included with the documentation the builder provides to the building owner at occupancy. �Certificite `" - Responsible Designer Name: z fAiispbhsible Designer Signature: "i Company: r Date Signed: Address: License: City/State/Zip: a Phone: For assistance or -questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300. Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 IBUILDING ENERGY ANALYSIS REPORT Luisa Lopez 52731 Avenida Bermudas La Quinta, Ca 92253 Project Designer: Lucas Coronel 77935 Calle Tampico La Quinta, Ca 92253 760.564.7514 Report Prepared by: Santiago Lopez-Ocampo Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, Ca 92247 760.485.8927 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONST UCTION DATE 1? Z� B Job Number: LQ092415 Date: 9/24/2015 RECEIVED DEC 1,7 2015 CITY OF LA QUINTA COMMUNITY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC—www.energysoft.com. EnergyPno 6.7 by EnergySoft User Number. 5732 ID: LQ092415 I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R -PRF -01-E Certificate of Compliance 3 Form RMS -1 Residential Measures Summary 10 Form MF -1 R Mandatory Measures Summary 11 HVAC System Heating and Cooling Loads Summary 15 EnergyPro 6.7 by EnergySoft Job Number. ID: LQ092415 User Number. 5732 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 52731 Avenida Bermudas Calculation Description: Title 24 Analysis Calculation Date/T(me: 16:04, Thu, Sep 24, 2015 Input File Name: 52731 Avenida Bermudas.xml CFI R -PRF -01 Pagel of 7 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name 52731 Avenida Bermudas 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location 52731 Avenida Bermudas Compliance Margin Percent Improvement 04 City La Quints 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 1 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 800 16 Number of Zones 1 16 Slab Area (ft=) 800 17 Number of Stories 1 18 Addition Cond. Floor Area 0 19 Natural Gas Available Yes 20 Addition Slab Area (ft) 0 21 Glazing Percentage (%) 14.6% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification a Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-09-2416:05:20 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 0.24 0.17 0.07 29.2% Space Cooling 190.14 189.15 0.99 0.5% IAO Ventilation 0.00 0.00 0.00 0.0% Water Heating 29.58 29.58 0.00 0.0% Photovoltaic Offset — 0.00 0.00 — Compliance Energy Total 219.96 218.90 1.06 0.6% Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-09-2416:05:20 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: 52731 Avenida Bermudas Calculation Date/Time: 16:04, Thu, Sep 24, 2015 Page 2 of 7 Calculation Description: Title 24 Analysis Input File Name: 52731 Avenida Bermudas.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. NO SPECIAL FEATURES REQUIRED HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Bulldingdevel Verifications: • —None — Cooling System Verifications: • —None -- HVAC Distribution System Verifications: • — None — Domestic Hot Water System Verifications: • —None — ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTOVtf2-yr)* 296.03 293.97 1.06 0.4% • Includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 06 06 07 Number of Dwelling Project Name Conditioned Floor Area (ft2) Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 52731 Avenida Bermudas 800 1 2 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (fit") Avg, Calling Height Water Heating System 1 Water Heating System 2 Existing Conditioned HVAC Systeml 800 9 DHW Sys 1 Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-09-2416:05:20 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 52731 Avenida Bermudas Calculation Datef ime: 16:04, Thu, Sep 24, 2015 Calculation Description: Title 24 Analysis Input File Name: 52731 Avenida Bermudas.xml CF1R-PRF-01 Page 3 of 7 OPAQUE SURFACES 01 02 03 04 06 06 07 08 09 10 Radiant Statu Verified Existing Name Construction 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ftz) Window & Door Area (f:2) Tilt (deg) Status Verified Existing Condition Ri/N Existing R-13 Wall 0 Right 200 24 90 Existing No Re/W Existing R-13 Wall 270 Batik 257 42.7 90 Existing No Le/S Existing R-13 Wall 180 Left 200 8 90 Existing No Fr/E Existing R-13 Wall 90 Front 257 62 90 Existing No Roof Existing R-00 Roof Attic Re/W (Back -270) - - 1 400 0.34 0.31 Existing No Root 2 Existing R-30 Roof Attic - 1 8.0 400 0.34 Insect Screen (default) Existing No ATTIC 01 02 03 04 06 06 07 08 09 10 Radiant Statu Verified Existing Name Construction Type Roof Rise Roof Reflectance Roof Emlttance Barrier Cool Roof a Condition Attic Existing Attic RoofExisting Ventilated 3 0.1 0.85 No No Enr9 No 11 Name Surface (Orientation -Azimuth) Width(ft) Multiplle Height (ft) r WINDOWS 01 02 03 04 06 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Multiplle Height (ft) r Area (ftz) U -factor SHGC Exterior Shading Status Verified Existing Condition 4040 XO Ri/N (Right -0) - - 1 16.0 0.34 0.31 Insect Screen (default) Altered N/A 2040 SH RUN (Right -0) - - 1 8.0 0.34 0.31 Insect Screen (default) Altered N/A 2040 SH 2 Re/W (Back -270) - - 1 8.0 0.34 0.31 Insect Screen (default) Altered N/A 2030 SH Re/W (Back -270) - - 1 6.0 0.34 0.31 Insect Screen (default) Altered N/A 2668 Or w/Half Glass Re/W (Back -270) - - 1 16.7 0.40 0.40 Insect Screen (default) Altered N/A 3040 XO Re/W (Back -270) - - 1 12.0 0.34 0.31 Insect Screen (default) Altered N/A 4020 FIX Le/S (Left -180) - - 1 8.0 0.33 0.34 Insect Screen (default) Altered N/A 3036 Fix Fr/E (Front -90) - - 1 10.5 0.34 0.31 Insect Screen (default) Altered N/A 6036 XO Fr/E (Front -90)- - 1 21.0 1.04 0.76 Insect Screen (default) Existing No 3036 XO Fr/E (Front -90) - - 1 10.5 1.04 0.76 Insect Screen (default) I Existing No Registration Number: Registration Date/rime: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFSR-08252015-744 HERS Provider: Report Generated at: 2015-09-2416:05:20 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 52731 Avenida Bermudas Calculation Date/Time: 16:04, Thu, Sep 24, 2015 Calculation Description: Title 24 Analysis Input File Name: 52731 Avenida Bermudas.xml CF1R-PRF-01 Page 4 of 7 DOORS 01 02 03 04 106 J 06 Name Side of Building Area (ft=) U -factor Status Verified Existing Condition 3068 Fr/E 20.0 0.50 Existing No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 06 06 07 08 09 Name Zone Total Cavity Winter Design Edge Insul. R -value Construction Name Surface Type Construction Type Framing R -value . U -value Assembly Layers 0.1 None 0.8 No Existing No • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck.- IAbod Siding/sheathing/decidng Attic RoofExisting Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) Inside Finish: Gypsum Board Cavity/Frame: R -13/2x4 Exterior Finish: 14bod R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.095 Siding/sheathing/deddng Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1/2(4 R-30 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 30 0.032 Over Floor Joists: R-20.9 insul. SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Slab -on -Grade Existing 800 0.1 None 0.8 No Existing No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (011) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required — WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 Annual Existing No Registration Number: Registration Date/rime: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-09-2416:05:20 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 52731 Avenida Bermudas Calculation DateMme: 16:04, Thu, Sep 24, 2015 Calculation Description: Title 24 Analysis Input File Name: 52731 Avenida Bermudas.xml CF1R-PRF-01 Page 6 of 7 WATER HEATERS 01 02 01 02 03 04 06 06 07 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Tank Exterior Input Rating Insulation R -value 1 Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.525 EF 28000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 01 02 03 04 06 06 07 Name Pipe Insulation Recirculation with Parallel Piping Compact Distribution Point -of Use Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 08 Multi -speed Heating System Cooling System System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 11.5 13 Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVAC Systeml Other Heating and Heating Yes Cooling I Yes Air Distribution HVAC Fan 800 Existing No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntriFurnace - Fuel -fired central furnace 78 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Efficiency Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 11.5 13 No No N/A system Registration Number: Registration Date/Tlme: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015.744 HERS Provider: Report Generated at: 2015-09-2416:05:20 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 52731 Avenida Bermudas Calculation DateMme: 16:04, Thu, Sep 24, 2015 Calculation Description: Title 24 Analysis Input File Name: 52731 Avenida Bermudas.xml CF1 R -PRF -01 Page 6 of 7 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 06 06 07 08 08 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Dud Status Condition Verification Air Distribution Ducts located in attic Existing (not 6.0 Attic Attic None Existing No N/A System 1 specified) HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 06 1 06 Name Dud Leakage Dud Leakage Verified Dud Design Verification Target (%) Verified Dud Location Return Supply Air Distribution System 1 -hers -dist N/A — — — I— IAO (Indoor Air Quality) FANS 01 02 03 04 06 Name IAQ CFM IAO Fan Type IAO Recovery Effectiveness(%) HERS Verification SFam IAQVenlRpt 0 Default 0 Not Required Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-09-2416:05:20 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 52731 Avenida Bermudas Calculation DateMme: 16:04, Thu, Sep 24, 2015 Calculation Description: Title 24 Analysis Input File Name: 52731 Avenida Bermudas.xml CF1 R -PRF -01 Page 7 of 7 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: - Documentation Author Signature: Santiago Lopez-Ocampo Company: Signature Date: Santiago Lopez-Ocampo 9/24/2015 Address: CEA/HERS Certification Identification (If applicable): P.O. Box 1018 city/slatIN Quinta, Ca 92247 Phone: 760.485.8927 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. . 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Company: Date Signed: Lucas Coronel Address: License: 77935 Calle Tampico City/State/zip: Phone: La Quinta, Ca 92253 760.564.7514 Registration Number: Registration Date/rime: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744 HERS Provider: Report Generated at: 2015-09-2416:05:20 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Luisa Lopez Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 9/24/2015 Project Address 52731 Avenida Bermudas La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 800 Addition 0 # of Units 1 INSULATION Construction Type Area Cavi(ft) Special Features Status Slab Unheated Slab -on -Grade - no insulation 800 Perim = 0' Existing Wall Wood Framed R 13 777 Existing Door Opaque Door - no insulation 20 Existing Roof Wood Framed Attic R 30 800 Existing FENESTRATION Orientation Area ft2 I Total Area: 117 Glazing Percentage: 14.6 % New/Altered Average U -Factor. 0.35 U -Fac SHGC Overhang Sidefins Exterior Shades Status Right (N) 16.0 0.340 0.31 none none Bug Screen Altered Right (N) 8.0 0.340 0.31 none none Bug Screen Altered Rear (VL9 14.0 0.340 0.31 none none Bug Screen Altered Rear (tM 16.7 0.400 0.40 none none Bug Screen Altered Rear (W) 12.0 0.340 0.31 none none Bug Screen Altered Left (S) 8.0 0.330 0.34 none none Bug Screen Altered Front (E) 10.5 0.340 0.31 none none Bug Screen Altered Front (E) 31.5 1.040 0.76 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC System Ducted Ducted Attic 6.0 Existing WATER HEATING . Qty. Type Gallons Min. Eff Distribution Status EnergyPro 6.7 by EnemvSoft User Number: 5732 Run Code: 2015.09-24716:05.53 ID: L 092415 Pae 10 of 15 2.013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. Exceptions may apply. Review the respective code section for more information. Building Envelope Measures: § 110.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets therequirements of § 10-111 (a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar ieflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CFIR. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. §150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). §150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §150.0(g)l: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class 11 §150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class 11 vapor retarder shall be placed over the earth floor of § 150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). §150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 § 150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)IB: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §150.0(e)IC: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § 150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §150.0(h)l: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). §150.00)1A: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. § 150.00)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system §150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. §150.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 2013 Low -Rise Residential Mandatory Measures Summary §I50.00)2C: Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For §150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)l: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5. §150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSUSMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)l; with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 'A inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints §150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §1!50.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § 150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §I50.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §150.0(m)13: space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_: 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §150.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2,013 Low -Rise Residential Mandatory Measures Summary §110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. §I 10.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - rammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §150.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-13, as applicable. §150.0(k)IB: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with §150.0(k)IC: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)ID: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)1F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § I50.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. §150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §150.0(k). §150.0(k)2F: Lighting controls comply with applicable requirements of §110.9. An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if. it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (FMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if. it § 150.0(k)2H: functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of 130.5; and all other requirements in §150.0(k)2. § 150.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in §150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only §150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. § I50.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § 150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: L Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the followin methods: .40 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §I50.0(k)9B: following requirements: i. Shall comply with §150.0(k)9A; or ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. § I50.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4 § 140.7 and § 141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. §150.0(k)10: Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). § I50.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9, § 130.0 § 130.1 § 130.4, § 140.6, and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of §150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: § 150.0(k)12B: i. Comply with the applicable requirements in § 110.9, § 130.0, § 130. 1, § 140.6 and § 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)l: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10 b through 110.10(e). §110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §110.10(b)l: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit §1 10.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. §110.10(e)l: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric'. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Luisa Lopez Date 9/24/2015 System Name HVAC System Floor Area 800 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation F Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 669 0 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 80,000 12,808 900 231 8,802 Total Output Btuh 80,000 0 Output Btuh/s ft 100.0 874 508 Cooling System 0 0 Output per System 1 0 0 0 0 Total Output Btuh 1 0 1 874 1 14,556 900 0 Total Output Tons 0.0 508 Total Output Btuh/s ft 0.0 Total Output (S-ft/Ton 9,600,000.0 9,818 Air System CFM per System 0 HVAC EQUIPMENT SELECTION Airflow cfm 0 Standard Fau/AC 1 0 80,000 Airflow cfm/s ft 0.00 Airflow cfm/Ton 0.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1 0 80,000 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air -4r 0 cfm 67 OF 67 OF 105 OF M Heating Coil 104 OF +wn ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 77/63°F 77/63°F 55/54°F Cooling Coil _II 57 55 0 48.5% Roots 75/62°F EnergyPro 6.7 by EnergySoft User Number. 5732 Run Code: 2015.09-24716:05:53 ID: LQ092415 Page 15 of 15