BRES2015-038878-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
Applicant:
LUCAS CORONEL
48820 EISENHOWER DR
LA QUINTA, CA 92253
Tir4lw4"
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
BRES2015-0388
52731 AVENIDA BERMUDAS
773305024
LOPEZ / PATIO COVER REPLACE WINDOWS RESTUCCO HOUSE
$10,000.00
DEC 28 2015
CITYOFLAQUIUTA
COMi1iUNITY DE'IELOP:L1CPIT DEPARTt"TIENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: _ License No.::SKH:1510061027531372
Date: Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant. for a
permit subjects the applicant to a civil penalty of.not more than five hundred dollars
\($500).:
(�lJfa's owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered fo'r sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees; provided that the improvements
are not intended or offered for sale: If, however, the building or improvement is sold
within one year.of completion, the owner -builder will have the burden of proving that
Tr she did not build or improve for the purpose of sale.j.
I, aspwner of the property, am exclusively contracting with licensed contractors
n uct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
qbe Contractors' State License Law.).
( -) Ijam exempt under Sec. B.&P.� for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
11111111111111111111
05
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 12/28/2015
Owner:
LOPEZ ELEUTERIO P ESTATE OF
Contractor:
LOPEZ ELEUTERIO P ESTATE OF
49608 ESCALANTE ST
INDIO, CA 92253
Llc. No.::SKH:1510061027531372
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: Polity Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to'become subject to the workers'
compensation laws of California, and agree that, if l should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date:
Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100;000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this. application:
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby ayuthorize representatives of this city to enter upon the
above-menYofor inspection purposes. �.
Date: Signature (Applicant or Agen
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT
QTY AMOUNT PAID
PAID DATE
BSAS SB1473 FEE 101-0000-20306
0 $1.00 $1.00
12/28/15
PAID BY METHOD
RECEIPT # CHECK #
CLTD BY
LUCAS CORONEL CHECK
R11784 2715.
SGU
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00
DESCRIPTION
ACCOUNT
QTY.
AMOUNT
PAID
PAID DATE
PATIO COVER, STD, OPEN
101-0000-42404
0
$97.17
$97.17
12/28/15
PAID BY
METHOD..:. `
RECEIPT-# •,
CHECK #
CLTD BY -
LUCAS CORONEL
CHECK
R11784
2715
SGU
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PATIO COVER, STD, OPEN PC
101-0000-42600
0
$95.72
$95.72
12/28/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
LUCAS CORONEL
CHECK
R11784
2715
SGU
Total Paid for PATIO COVER / COVERED PORCH / LATTICE: $192.89 $192.89
DESCRIPTION
ACCOUNT ;' .'
QTY
AMOUNT ;.
PAID
PAID DATE
SMI - RESIDENTIAL
101-0000-20308
0
$1.30
$1.30
12/28/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
LUCAS CORONEL
CHECK
R11784
2715
SGU
Total Paid'for STRONG MOTION INSTRUMENTATION SMI: $1.30 $1.30
DESCRIPTION -
ACCOUNT;
QTY
AMOUNT
PAID
PAID'DAT£
STUCCO APPLICATION,, EA ADDITIONAL 500
SF
101-0000-42404
0
$14.50
$14.50
12/28/15
PAID BY
METHOD
RECEIPT #
CHECK # '.
CLTD BY
LUCAS CORONEL
CHECK
R11784
2715
SGU
DESCRIPTION
ACCOUNT
QTY
AMOUNT
� PAID
PAID DATE,
STUCCO APPLICATION,. FIRST 500 SF
101-0000-42404
0
..$24.66
$24.66
12/28/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
LUCAS CORONEL
CHECK
R11784
2715
SGU
DESCRIPTION
ACCOUNT
QTY-:
AMOUNT
PAID
PAID DATE
STUCCO APPLICATION, FIRST 500 SF PC
101-0000-42600
0
$73.97.
$73.97
12/28/15
.PAID BY
METHOD" .
RECEIPT # `:
.. CHECK #
"CLTD BY `
LUCAS CORONEL
CHECK
R11784
2715
SGU
Total Paid for STUCCO APPLICATION: $113.13 $113.13
DESCRIPTION
ACCOUNTQTY.
AMOUNT .
PAID
PAID DATE,
DOOR/WINDOW, REPLACE FIRST 7
101-0000-42400
0
$60.91
$60.91
12/28/15
PAID BY
METHOD
'RECEIPT #
CHECK #
CLTD BY
LUCAS CORONEL
CHECK
R11784
2715
SGU
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DOOR/WINDOW, REPLACE, EA ADDITION 5
101-0000-42400.
0
$10.15
$10AS
12/28/15
PAID BY
METHOD
_. RECEIPT #
CHECK #
CLTD BY
LUCAS CORONEL
CHECK
R11784
2715
SGU
r
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DOOR/WINDOW, REPLACE, EA ADDITIONS
PC
101=0000-42600
0
$11.60
$11.60 '
12/28/15
PAID BY ;.
METHOD
RECEIPT #
CHECK #
CLTD BY
LUCAS CORONEL
CHECK
R11784
2715
SGU
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DOOR/WINDOW, REPLACE, FIRST 7 PC
101-0000-42600
0
-$110.22
$110.22
12/28/15
PAID BY
METHOD
RECEIPT # .
CHECK #
CLTD BY
LUCAS CORONEL
CHECK
R11784
2715
SGU
Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $192.88 $192.88
TOTALS:•
Description: LOPEZ / PATIO COVER REPLACE WINDOWS RESTUCCO HOUSE
Type: BUILDING, RESIDENTIAL Subtype: REMODEL Status: APPROVED
Applied: 10/6/2015 SGU
Approved: 12/28/2015 JJO
Parcel No: 773305024 Site Address: 52731 AVENIDA BERMUDAS LA QUINTA,CA 92253
Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 140 Lot: 11
Issued:
UNIT 15
CHRONOLOGY TYPE
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $10,000.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
STEPHANIE GUMPERT
Details: REPAIR AND REMODEL EXISTING 275 SQ. FT. PATIO PER CITY SPECS, REPLACE WINDOW AND DOORS ANDRE STUCCO HOUSE.
Printed: Monday, December 28, 2015 9:32:22 AM 1 of 3 CN
SYS7Eti1S
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
PLAN CHECK PICKED UP
STEPHANIE GUMPERT
10/26/2015
10/26/2015
PICKED UP BY LUCAS
PLAN CHECK SUBMITTAL
RECEIVED
STEPHANIE GUMPERT
10/6/2015
10/6/2015
PLAN CHECK SUBMITTAL
RECEIVED
STEPHANIE GUMPERT
12/17/2015
12/17/2015
TELEPHONE CALL
JIM JOHNSON
10/8/2015
10/8/2015
CALLED LUCAS CORONEL TO INFORM HIM THE PLANS ARE
READY CORRECTIONS
TELEPHONE CALL
JIM JOHNSON
12/28/2015
12/28/2015
CALLED OWNER TO INFORM HIM PLANS ARE READY TO
ISSUE.
CONDITIONS
Printed: Monday, December 28, 2015 9:32:22 AM 1 of 3 CN
SYS7Eti1S
FINANCIAL •'
•
.DESCRIPTION ACCOUNT . QTY AMOUNT PAID
CONTACTS
BY
NAME TYPE
NAME
ADDRESSI
CITY .
STATE
ZIP PHONE FAX EMAIL
APPLICANT
LUCAS CORONEL
48820 EISENHOWER DR
LA QUINTA
CA
92253
CONTRACTOR
LOPEZ ELEUTERIO P ESTATE OF
49608 ESCALANTE ST
INDIO
CA
92253
OWNER
LOPEZ ELEUTERIO P ESTATE OF
49608 ESCALANTE ST
INDIO
CA
92253
FINANCIAL •'
•
.DESCRIPTION ACCOUNT . QTY AMOUNT PAID
PAID DATE RECEIPT. CHECK q, METHOD PAID BY CLTD
!#
BY
BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00
12/28/15 R11784 2715 CHECK LUCAS. CORONEL SGU
Total Paid for BUILDING STANDARDS ADMINISTRATION
$1.00 $1.00
BSA:
PATIO COVER, STD,
101-0000-42404
0
: $97.17
$97.17
12/28/15
R11784
2715.
CHECK
LUCAS CORONEL
SGU
OPEN
PATIO COVER, STD,
101-0000-42606
0
$95.72
$95.72
12/28/15
R11784
2715
CHECK
LUCAS CORONEL
SGU
OPEN PC
Total Paid for PATIO COVER / COVERED PORCH / LATTICE: $192.89 $192.89
SMI -RESIDENTIAL
101-0000-20308
0
$1.30
$1.30
12/28/15
R11784
2715
CHECK
LUCAS CORONEL
SGU,
Total Paid for STRONG. MOTION INSTRUMENTATION SMI: $1.30 $1.30
STUCCO APPLICATION,
101-0000-42404
0
$14.50
$14.50
12/18/15
R11784
2715
CHECK
LUCAS CORONEL
SGU
EA ADDITIONAL 500 SF
STUCCO APPLICATION,
101-0000-42404
'0
$24.66
$24.66
12/28/15
R11784
2715
CHECK
LUCAS CORONEL
SGU
FIRST 500 SF
STUCCO APPLICATION,
101-0000-42600
0
$73.97
$73.97
12/28/15
R11784
2715
CHECK
LUCAS CORONEL
SGU
FIRST 500 SF PC
Total Paid for STUCCO APP LICATION:• $113.13 $113.13
DOOR/WINDOW,
101-0000-42400
0
$60.91
$60.91
12/28/15
R11784
2715
CHECK
LUCAS CORONEL
SGU
REPLACE FIRST 7
DOOR/WINDOW,
REPLACE, EA ADDITION
101-0000-42400
.0
$10.15
$10.15
12/28/15
R11784
2715
CHECK
LUCAS CORONEL
SGU
5
Printed: Monday, December 28, 2015 9:32:22 AM 2 of 3 C9?
SYSTEMS
tT .• Permit Details PERMIT NUMBER
City of La Quinta BRES2015=0388
INSPECTIONS
PARENT PROJECTS
INFORMATION
OWNER
DESCRIPTION
ATTACHMENTS
REVIEWS
DOC
10/8/2015
REVIEW TYPE
REVIEWER
CLTD
DUE DATE
RETURNED
DATE
STATUS
REMARKS
NOTES
1ST BLDG NS (1 WK)
JIM JOHNSON
10/6/2015
10/13/2015
DESCRIPTION
ACCOUNT, ..
..
QTY
AMOUNT
• PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY -
BY
DOOR/WINDOW;
REPLACE; EA ADDITION
101-0000-42600
0
$11.60
$11.60
12/28/15
R11784
2715
CHECK
LUCAS CORONEL
SGU
5 PC
DOOR/WINDOW,
101-0000-42600
0
$110.22
$110.22
12/28/15
R11784
2715
CHECK
LUCAS CORONEL
SGU
REPLACE, FIRST 7 PC
Total Paid for WINDOW/SLIDING GLASS
$192.88 $192.88
' DOOR/FENESTRATION:.
INSPECTIONS
PARENT PROJECTS
BOND
INFORMATION
OWNER
DESCRIPTION
ATTACHMENTS
REVIEWS
DOC
10/8/2015
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
RETURNED
DATE
STATUS
REMARKS
NOTES
1ST BLDG NS (1 WK)
JIM JOHNSON
10/6/2015
10/13/2015
10/8/2015
REVISIONS REQUIRED
2ND BLDG NS (1
WK)
JIM JOHNSON
12/17/2015
12/28/2015
12/28/2015
APPROVED
BOND
INFORMATION
OWNER
DESCRIPTION
ATTACHMENTS
SUBDIR ETRAKIT ENABLED
DOC
10/8/2015
JIM JOHNSON
BRES2015-0388.docx
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR ETRAKIT ENABLED
DOC
10/8/2015
JIM JOHNSON
BRES2015-0388.docx
BRES2015-0388.docx
0
Printed: Monday, December 28, 2015 9:32:22 AM 3 of 3
SYSTEMS
5
Bin City of La Quin to
Building 8i' Safety Division
Permit #1 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Project Address: Owner's Name: 4U/ S GZ
A. ber:
773— 30.5— ��
Address:
Legal Description: [ dXJ—le—
"I V
City, ST, Zip: �
Contractor: r
.
Telephone: �
............
Address: Vii)
Project Description:
City, ST, Zip: �(f
oLe e, 1 Nre d,)
Telephone: w/
9"
—
� n t;
e� CX S
/t
State Lic. 1,4J
City Lic. #;
Designer: u e
Address: ��Zv
City., ST, Zip:
hone: Zd
Occupancy:
�ConstruTele
ancY(�
cti n TYPe• t�
Lic. #: -
New wAdd'n Alter Repairair Demo
Project type
Name of Contact Person: U
Sq. Ft.:
# Stories:
# Units:
Telephone # of Contact Person:
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Rcc'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Cafes.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance.
Title 24 Calcs.
Plans picked up
Construction .
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2"" Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
Ii.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'rd Reyiew, ready for corrections/issue
Developer Impact Fee
Planning Approval'
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees,
Total Permit Fees
,CZ
Td -f 44Q"
COMMUNITY DEVELOPMENT DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
(760) 777-7125 FAX (760) 777-7011
RESIDENTIAL PLAN CHECK CORRECTION LIST (os)
DATE: 10/8/2015
STATUS: FIRST REVIEW
PLAN CHECKED BY: JIM JOHNSON
TELEPHONE NUMBER: (760) 777-7130
ADDRESS: 52-731 AVE BERMUDAS
DESCRIPTION: REMODEL
APPLICANT: LOPEZ
PLAN CHECK #: BRES2015-0388
This submittal has been checked for compliance with the 2013 California Residential, Mechanical, Electrical,
Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code.
APPLICANT: BUILDING DEPARTMENT STAFF:
The following items are being returned to you for DO NOT accept any resubmittal unless ALL of the
correction: following items are included:
1 SET OF PLANS
1 SETS TITLE -24
1 SET CITY SPEC, PATIO
THIS CORRECTION LIST
REDLINED SET
2 NEW REVISED SETS
1 ASSESSORS SET
2 SETS TITLE -24
2 CITY SPECS ( PATIO DETAILS)
THIS CORRECTION LIST / RESPONSES
INSTRUCTIONS TO APPLICANT:
1) Provide a written response'to each comment on the following pages, noting specifically where the correction
can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not
acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses
such as, "Added note 16 on sheet A=3" are appropriate and will help expedite your back check.
2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or
Calculations as necessary.
3) Return all red -marked Plans and/or Calculations with your resubmittal.
4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number
and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and
Professions Code Section 5536. Resubmittals will not be accepted with signatures missing.
5) Return this list, your written responses, and all documents listed above with your resubmittal.
Residential Plan Check Correction List Page] of 2
SECTION A - GENERAL
1) Provide the Assessor's Parcel Number (APN) and complete legal description of Project on the first sheet of
Plans. LOT 11, APN # 773-305-024
2) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and
telephone number and wet -signature. If the preparer is a licensed architect or -engineer, all documents
prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and
Professions Code §5536. Resubmittals will not be accepted -with signatures missing.
3) Note on Plans: "All construction shall comply with the 2013 California Residential, Mechanical, Electrical,
Plumbing, Energy, and Green Building Codes and the La Quinta Municipal Code." Remove notes referencing
other Codes.
SECTION C - ARCHITECTURAL
1) Show on Floor Plan or Window Schedule all locations of windows requiring safety glazing. (CRC §R308.4)
See Floor Plan for area(s)
SECTION K - MISCELLANEOUS COMMENTS
1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise
Plans as necessary and provide written response, noting where correction can be found.
2) Provide one copy each of the Site Plan and Floor Plan for the County Assessor's office. While not required
for resubmittal, this administrative item must be addressed prior to issuance of building permit.
END CORRECTION LIST
As further information is provided and reviewed, additional corrections may be required.
Residential Plan Check Correction List Page 2 of 2
BUILDING & SAFETY DEPARTMENT
78-495 CALLE TAMPICO (760) 777-7012
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
Considering Becoming an Owner -Builder?
Important information you need to know BEFORE pulling your permit!
The term "Owner -Builder" can mean three different things:
"Owner as Worker", "Owner as Contractor" or "Owner as Employer"
Understand each has Benefits or Risk, and it is possible to combine them!
Hiring a California Licensed Contractor means you do not personally perform any of the construction work, the permit is not taken
out in your name, you are not personally responsible for the construction and you are not an Owner -Builder. Instead, you become a
"Cusfomer" and California law provides you the benefit of protection from poor workmanship, failure to finish the job and financial
risk due to worker injury.
Benefit/Risk: Highest Benefits and the Least amount of Risk
Owner -as -Worker is a type of Owner -Builder where you personally perform the construction. work, the permit is taken out in your
name and you are personally responsible for the construction management, knowledge, workmanship, and completion of the job. You
benefit by not paying others to perform this work for you and your risk depends on your own ability to complete the job successfully.
Benefit/Risk: Possible Benefit with Low Financial Risk
Owner -as -Contractor is a type of Owner -Builder where you personally act as your own General Contractor, the permit is taken out in
your name and you hire California licensed sub -contractors to perform portions of the construction work. WARNING: The benefit of
protection provided by law when you hire only California licensed sub -contractors can turn to serious financial risk if you hire
unlicensed contractors to perform any of the work.
Benefit/Risk: Possible Benefit and Significant Financial Risk
Owner -as -Employer is a type of.Owner-Builder where you pay any unlicensed individual to perform any construction work valued at
more than $500.00, the permit is taken .out in your name and you are. personally responsible for their employment requirements,
supervision, performance, safety and welfare while on your property. WARNING: Cost savings benefit can turn'to serious financial
risk if you fail to deduct payroll taxes or provide workers compensation insurance for each worker.
Benefit/Risk: Possible Benefit with Significant Financial Risk
(Health and Safety Code Section 19827) The California Legislature declares an "urgent and statewide
public interest in assuring" that contractors comply with Contractors' License Law, Business and
Professions Code and Workers' Compensation Insurance requirements to ensure property owners are
informed about, and protected from the following when. improving their property as Owner -Builders:
Fraudulent representations - Liability for worker's injuries • Liability for material and labor costs unpaid by
contractors • Licensing requirements - Employers tax liabilities
Over 20,000 consumer complaints are filed each year. Many complaints relate to owner/builder projects
and include workmanship and workers' compensation issues Homeowners suffer financial harm due to
defective workmanship and injured employees.
Following are alarming examples of what has occurred with Owner -Builder permits:
Example 1: Homeowner received insurance money to rebuild burned -down home.
■ Owner/Builder permit pulled to rebuild structure.
■ Unlicensed contractor built substandard structure — must be torn down and replaced.
■ Estimated financial injury is $225,000.
■ Additional financial injury - IRS threatened to tax insurance payout if house not completed by the end of
the year.
Example 2: Brother-in-law had active license but fled an exemption from Workers Comp..
• Owner -Builder hires brother-in-law to install a new roof.
■
.Employee falls and sustains multiple spinal and extremity fractures as well as ahead injury and
remains in a coma to this day.
■ The Owner -Builder, who has sold the home, is now a defendant.in a lawsuit for reimbursement for
benefits paid to the injured worker.
Example 3: Employee of contractor without Workers Comp is hired by Owner -Builder to install septic
system and suffers injury that results in permanent disability.
• The Owner -Builder did not have a homeowner's insurance policy on the house against which to submit
a claim.
■ The Owner -Builder is now a defendant in a lawsuit for reimbursement for benefits paid to the injured
worker.
Did you know — unlicensed persons frequently have the property owner obtain an "Owner -Builder" building
permit which erroneously implies that the property owner is providing his or her own labor and material
personally?
Did you know — your homeowner's insurance may not provide coverage for injuries sustained on your
property by an unlicensed contractor and his/her employees?
Did you know — if you are considered an "employer" under state and federal law, you must. register with
the state and federal government, withhold payroll taxes, provide workers compensation and disability
insurance and contribute to unemployment compensation for each "employee"?
Did you know — that if you fail to abide by these laws you may be subjected to serious financial risk?.
OWNERS BEWARE AND CONSIDER THE RISK BEFORE ACCEPTING FULL RESPONSIBILITY FOR
YOUR CONSTRUCTION PERMIT
Tdf 4 4 QUM&
P.D. Box 1504
LA QUINTA, CALIFORNIA 92247-1504
78-495 CALLS TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
PROPERTY OWNER'S PACKAGE
(760)777-7012
FAX (760) 777-7011
Disclosures & Forms for Owner -Builders Applying for Construction Permits
IMPORTANT! NOTICE TO PROPERTY OWNER
Dear Property Owner:
An application for a Building permit has bf en submitted in your name listing yourself as. the builder of the property
improvements specified at 5'"Z 1 3C r+ "t_ &-eV 'vas L-
We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your
responsibilities and possible risk you may incur by having this permit issued in your name as the
Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision,
signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice
unless you, the property owner, obtain the prior approval of the permitting authority.
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION
DIRECTIONS: Read and initial each statement below. to signify you understand or verify this information.
��derstand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder"
flgmit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as
an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those
injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers
on my p
e d building permits are not required to be signed by property owners unless they are responsible for the
construction and are not hiring a licensed Contractor to assume this responsibility.
C �3. I understand as an "Owner -Builder" I am the responsible party of record on the permit I understand that I may protect
myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of rriy
own.
4. I un rstand Contractors are required by law to be licensed and bonded in California and to list their license numbers on
is anpgontracts.
un erstand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value
of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer"
der state and federal law.64::��un-
derstand if I am considered an "employer" under state and federal law, I must register with the state and federal
government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment
compensation for each "employee." I also understand my failure to abide by these laws may subject me to.serious financial
ris .
Q4J_Iunderstand under California Contractors' State License Law, an Owner-Builder.who builds single-family residential
structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed
subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed
under contract with a licensed general building Contractor.
�. I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any
financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the
workmanship or materials.
Z
I may obtain more information regarding my obligations as an "employer" from the Internal Revenue
Cervice, the United States Small.Business Administration, the California Department of Benefit Payments, and the California
Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-
800-32 1 -CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors.
1 am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the
party legally: and financially responsible ' for proposed construction' activity at the following address:
gree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all
applicable laws and requirements that govern Owner -Builders asmell as employers.
agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I
have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with
someone who does not have a license, the Contractors' State License Board may be unable to assist you with -any financial loss
you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be .in civil court. It is also
important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working
on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors,
you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers'
compensation insurance coverage.
Before a building permit can be issued, this form must be completed and signed by the property owner and returned to
the agency responsible for issuingAe permit. Note: A copy of the property owner's driver's license, form notarization, or
other verification acceptable to t e gency is required to b esented when the permit is issued to verify the property
owner's signature.
Signature of property owner Date: 0
Note: The following Authorization Form is required to be completed by the property owner only when designating
an agent of the property owner to apply for a construction permit for the Owner -Builder.
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize
the following person(s) to act as my agents) to apply for, sign, and file the documents necessary to obtain an Owner -Builder
Permit for my project. a i Past, Scope of Construction Project (or Description of Work): K,D ll , P, �ti� c��S _ I�z Lj-t I �( e�—� i,,
S �--X31 -c_ . _ \
Project Location or Address: _/ v cQr,� : . si CdI—
Name of Authorized Agent:
Address of Authorized Agent:
Tel Noom
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above
information and certify its accurac r Note. -,4 copy of the owne ' driver's license, form notarization, or other verification
acceptable to the agency is requi a to be presented when t permit is issued to verify the property ow er s signature.
Property Owner's Signature: Date:
RATER SIZE Am SPACr1C SPEOFY ROOFING AlO SNEAD"NC OR OPEN lAR1,'•T --�
ZL.t 1(----- oF
(SEE Ro�N =EVE
NOTE ON RRSE)
-- /
Roof MCN
(SAW SCE -AS wn:pM
HCAMpI S=
-q �� _-
s2 y it
iFTER SPEW: .
fit
2000 P.s.I co"cnm —»: " i nmm 1
L_J
a" LATTICE PAhO COVERS NAY 6E
ATTACHED T
MA ONE 114' r S MI
LAC SCREW TOIJCM MO EACH `RA TER TML_
1/6- • S' LAC SCREWS MO STUDS AT 16. O.C.
r Oumwous t.Epco i
X
If Fonda ''rid 7:00 a.. 5:3
,�tv day: 00 a.m. to 5:
uciday:
Govprpment Colc ffil!,days: None
=r ►w mR OR i4xFe1�C,Q,C
IE'Iav 1 s - S-n�cmber (OiH
Saturday: 8:00 a.m. to 5:00 P.M.
Sunday: None
DEPARTMENT APPROVAL BELOW
RE @1 i`� QvIn,
COLING & S TA
D C 1 7APPR V� �EpT
CI OF LA S JI I�TRNST CTION
COMM NITY DEVELOPMENT , /
(FFIC� [cop�
'r AM V STRAPS . Ill
(t) 164 ►w1S OR 8011
POST-S1'A0Ww--�!
_ POSM; yyo
`_L- -- Wt train notwc 1 <' .
tr BEL M' ORA,DE L _ J
PROV0E t C1 EAR NCE
BETWEEN POST AM
CONCRETE
Lt1rJO ill.t t7P1 4`=1 OIL
Aar$ag Ca°dgoii
New Year's
Dr. Martin Lu
President's Day
°RMpendence Day
I ab�nrDay
u-sWerwk &ILE =
0R %rTstmas Day
PRO"X T' CLEARANCE
BETWEEN POST MD
ANCHOR BOLT (EMBED —
T MIN. INTO CONCRETE)
. TYPICAL PATIO COYER
DATE Of APPLCAT*N ,S
OWNER'S NAME G�
STREET AOOREss5Z-7. A,, e P,,v�
Mr. ST ZIP
vi
TELEPHONE '� I 39Q�r jz
�f
1 SA
mcso
2000 P.s.I co"cnm —»: " i nmm 1
L_J
a" LATTICE PAhO COVERS NAY 6E
ATTACHED T
MA ONE 114' r S MI
LAC SCREW TOIJCM MO EACH `RA TER TML_
1/6- • S' LAC SCREWS MO STUDS AT 16. O.C.
r Oumwous t.Epco i
X
If Fonda ''rid 7:00 a.. 5:3
,�tv day: 00 a.m. to 5:
uciday:
Govprpment Colc ffil!,days: None
=r ►w mR OR i4xFe1�C,Q,C
IE'Iav 1 s - S-n�cmber (OiH
Saturday: 8:00 a.m. to 5:00 P.M.
Sunday: None
DEPARTMENT APPROVAL BELOW
RE @1 i`� QvIn,
COLING & S TA
D C 1 7APPR V� �EpT
CI OF LA S JI I�TRNST CTION
COMM NITY DEVELOPMENT , /
(FFIC� [cop�
'r AM V STRAPS . Ill
(t) 164 ►w1S OR 8011
POST-S1'A0Ww--�!
_ POSM; yyo
`_L- -- Wt train notwc 1 <' .
tr BEL M' ORA,DE L _ J
PROV0E t C1 EAR NCE
BETWEEN POST AM
CONCRETE
Lt1rJO ill.t t7P1 4`=1 OIL
Aar$ag Ca°dgoii
New Year's
Dr. Martin Lu
President's Day
°RMpendence Day
I ab�nrDay
u-sWerwk &ILE =
0R %rTstmas Day
PRO"X T' CLEARANCE
BETWEEN POST MD
ANCHOR BOLT (EMBED —
T MIN. INTO CONCRETE)
. TYPICAL PATIO COYER
DATE Of APPLCAT*N ,S
OWNER'S NAME G�
STREET AOOREss5Z-7. A,, e P,,v�
Mr. ST ZIP
vi
TELEPHONE '� I 39Q�r jz
� 1Y
NOTES:
1. 32' RAFTER SPACING IS ALLOWABLE
FOR OPEN LATTICE PATIO COVERS ONLY.
2. FOR SOLID. PATIO COVERS (NOT LATTICE)
RAFTER "PAN IS LIMITED TO. 10'-0' USING .
THIS STANDARD,
LATTICE ROOF BUILT—UP ROOF
HEADERS HEADERS
DOUGLAS FIR NO. 1 DOUGLAS FIR NO. 1
ALL CONSTRUCTION SHALL CONFOR
TO THE PROVISIONS OF THE ..
SIZE SPAN 1. SIZESpgN I ROOFING NOTES:
27S 59 c"r
4x4 3'=0" 4x4 A. BUILT—UP. ROLLED ROOF: SLOPE TO DRAIN.
4x6 8'—O' 4z6 _ 6•_0
4x8 1 1'—p 4x8 8. :ROCK ROOF: 3/12 MAXIMUM PITCH.
4x10 14'-0 4x10_ 4x`12 17'—p 4x12
6x8 14'=p" 6x8 1 -9:1 .
6x10 17'—p. —6x10 14'
RAFTER SPAN TABLE
: � .� ' ' i:
GRADING RULES
PS 20-70
_c� C-7
FEET & INCHES
2x4 16' O.C. 1 —
g _� �•_ :R:_4-
24
2x6 16' O.C.
24
24 16' O.C.
IF
24" �-
' ='— i JL -0' ;13'-0`.
NOTES:
1. 32' RAFTER SPACING IS ALLOWABLE
FOR OPEN LATTICE PATIO COVERS ONLY.
2. FOR SOLID. PATIO COVERS (NOT LATTICE)
RAFTER "PAN IS LIMITED TO. 10'-0' USING .
THIS STANDARD,
LATTICE ROOF BUILT—UP ROOF
HEADERS HEADERS
DOUGLAS FIR NO. 1 DOUGLAS FIR NO. 1
ALL CONSTRUCTION SHALL CONFOR
TO THE PROVISIONS OF THE ..
SIZE SPAN 1. SIZESpgN I ROOFING NOTES:
27S 59 c"r
4x4 3'=0" 4x4 A. BUILT—UP. ROLLED ROOF: SLOPE TO DRAIN.
4x6 8'—O' 4z6 _ 6•_0
4x8 1 1'—p 4x8 8. :ROCK ROOF: 3/12 MAXIMUM PITCH.
4x10 14'-0 4x10_ 4x`12 17'—p 4x12
6x8 14'=p" 6x8 1 -9:1 .
6x10 17'—p. —6x10 14'
1�1
55 x 25.5
f1h.
C> - b
N
A
W e
24 x
STATE OF CALIFORNIA
RESIDENTIAL ALTERATIONS
CEC-CFIR-ALT-01-E Revised 06/14 CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE CF1R-ALT-01-E
Prescriptive Residential Alterations (Page 1 of 4)
Project Name: Date Prepared:
A. GENERAL INFORMATION
01
02
01 Project Name: ,572— 3 _ e/
02
Date Prepared:
03 Project Location:
197 457S04
Building Front Orieritation(deg or cardinal):
05 CA City:
06
Number of Altered proielling Units: '
07 Zip Code:
08
Fuel Typg: J(�
09 Climate Zone:
10
Total Conditioned Floor Area 104:1
11 Building Type
12
51ab,Area'(ft2) L.1=
13 Project Scope:
4eck�
ik. ' I& N- I M L 1 r-% \ I I
B. BUILDING INSULATION DETAILS (Section 150.2(b)1) � w
01
02
03
04
05 06 e--,'$," 07 I 081H" 99
10
1
Tag/ID
Assembly Type
Frame
Type
Frame
Depth
(inches)
fProposed 41- t\"" A
o , Appendix JA4
Frame Continuous
Reference
Spacing Cavityi Insulation
NI
(inches) R -value R -value a� 3 U f 2tor Table. Cell
Required
`5 W /� C/) m
Li 0.'S i Z
®� r
t( z'
��im;rraent
LI -Factor
Initial Solar Aged Solar Thermal SRI Aged Solar Thermal SRI
Method of
Roof
X.
4eck�
Compliance
Pitch
Exception
i; r NumXodutt
roduct Type _
,In ulation
Reflectance Reflectance Emittance (Optional) Reflectance Emittance (Optional)
UJ I
C. ROOF REPLACEMENT (Prescriptive Alteration, S oA'A-S0.2(b)1H),\� 1* 1a J
01
02
03
04 9N:
05\
06
ti�' °0.7�` 08 09 10. 11 12 13
*
U
R value
vo Proposed Minimum Required
Initial Solar Aged Solar Thermal SRI Aged Solar Thermal SRI
Method of
Roof
CRRC R.cD
Iber
4eck�
Compliance
Pitch
Exception
i; r NumXodutt
roduct Type _
,In ulation
Reflectance Reflectance Emittance (Optional) Reflectance Emittance (Optional)
'N
o�
NOTESRoof
area covered by, buildigg_integrate�d� photovoltaic panels and solar therms panels are exempt from the above Cool Roof requirements.
• Liquid field coat ngs5must stallation
applied comply with, ni criteria from section 110.8(1)4.
ti. C �
F
!
N�- -
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
DEC 17 2015
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
HERS Provider:
June 2014
J/
STATE OF CALIFORNIA
RESIDENTIAL ALTERATIONS
CEC-CFIR-ALT-01-E Revised 06114 CALIFORNIA ENERGY COMMISSION I Am
CERTIFICATE OF COMPLIANCE CF111-ALT-01-E
Prescriptive Residential Alterations (Page 2 of 4)
Project Name: Date Prepared:
D. FENESTRATION/GLAZING AREAS ALLOWED (Section 150.2(b)1)
04--, "
01 02 03
Alteration Type Orientation Maximum Allowed ft2 COMme fs
.-NIX ON�
E. FENESTRATION/GLAZING PROPOSED AREAS AND EFFICIENCIES (Section 150.2(b)1)�
01
02
03
04
05
06
07
08
Ae 4t
09
10'
>
11
12
13
14
15
Combined
Tag/
Fenestration
Frame
Dynamic
Orientation
N, 5, W, E, or
Area
Removed
Area �
Added
NYet
Added
Maximumk
Allowed
*
Exterior
Shading
SHGC
from
ID
Type
Type
Glazing
Roof
ft2
ft2
Area ft2
U factor
U -factor
Source
SHGC
Source
Device
CFIR ENV 03
Al
o
't,
n
.....
a
Net Added Wes nestration
'2
,f.ah �A�ea
;�
`
b
Existing + Added W�est',fa ing Fene�stratlo U.,rea
c
Maximum �lfdwedd West -facing= s str'ation Area,
d
Is West -facing Fenestration Area,,< Maximum Allowed Wesi--'facing Fenestration
C,.
Ar'rea,,
e
Net Added fen}estraion Area (all oien'tations)
f
Existing +Added;F stration Area (all"of en�tations)
g
t�
ns)
40% MaximumrA lowed Fenestration Area (all orientations)
Is Existing + gild%ed Fenestration Area < Maximum Allowed Fenestration Area (all
( orientations)
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014
STATE OF CALIFORNIA
RESIDENTIAL ALTERATIONS
CEC-CFIR-ALT-01-E Revised 06/14
CERTIFICATE OF COMPLIANCE
j Prescriptive Residential Alterations
Proiect Name:
Date
IM
CF1R-ALT-01-E
(Page 4 of 41
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
-.'Ak
Company:
Signature Date: $.
"Y 9Z .
"
Address:
CEA/ HERS Certification Ide tlric ition'(if applicable l:
City/State/Zip:
Phone:, x-.
_
1.
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California: V
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building de n or system design identified on this Certificate of Compliance (responsible
designer).
3. That the energy features and performance specifications, materials, components, and manufactured66&sfor the building design or system design identified on this Certificate of
Compliance
conform to the requirements of Title 24, Part 1 and Part 6 of the Cal
p q I ornia Code oftiZegulations.
4. The building design features or system design features identified on thisCertificate of Compliance are consister. itt the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted:to the enforcement a eri ='for 'm
p p g cy, pproval with this building permit application.
i`
`la
5. 1 will ensure that a registered co h `'
g copy of this Certificate of Complianeeashall be made available with the building permits) issued for the building, and made available to the enforcement agency
for all applicable inspections. 1 that C Mato
understand a registered copy of this of mpliance isir be included with the documentation the builder provides to the building
owner at occupancy.
�Certificite
`" -
Responsible Designer Name: z fAiispbhsible Designer Signature:
"i
Company: r
Date Signed:
Address:
License:
City/State/Zip: a
Phone:
For assistance or -questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300.
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014
IBUILDING ENERGY ANALYSIS REPORT
Luisa Lopez
52731 Avenida Bermudas
La Quinta, Ca 92253
Project Designer:
Lucas Coronel
77935 Calle Tampico
La Quinta, Ca 92253
760.564.7514
Report Prepared by:
Santiago Lopez-Ocampo
Santiago Lopez-Ocampo
P.O. Box 1018
La Quinta, Ca 92247
760.485.8927
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONST UCTION
DATE 1? Z� B
Job Number:
LQ092415
Date:
9/24/2015
RECEIVED
DEC 1,7 2015
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC—www.energysoft.com.
EnergyPno 6.7 by EnergySoft User Number. 5732 ID: LQ092415
I TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF -1 R -PRF -01-E Certificate of Compliance 3
Form RMS -1 Residential Measures Summary 10
Form MF -1 R Mandatory Measures Summary 11
HVAC System Heating and Cooling Loads Summary 15
EnergyPro 6.7 by EnergySoft Job Number. ID: LQ092415 User Number. 5732
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 52731 Avenida Bermudas
Calculation Description: Title 24 Analysis
Calculation Date/T(me: 16:04, Thu, Sep 24, 2015
Input File Name: 52731 Avenida Bermudas.xml
CFI R -PRF -01
Pagel of 7
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name 52731 Avenida Bermudas
04
05
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location 52731 Avenida Bermudas
Compliance Margin
Percent Improvement
04
City La Quints
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
1 Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 90
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2) 800
16
Number of Zones 1
16
Slab Area (ft=) 800
17
Number of Stories 1
18
Addition Cond. Floor Area 0
19
Natural Gas Available Yes
20
Addition Slab Area (ft) 0
21
Glazing Percentage (%) 14.6%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
a
Registration Number:
Registration Date/Time:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-09-2416:05:20
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
0.24
0.17
0.07
29.2%
Space Cooling
190.14
189.15
0.99
0.5%
IAO Ventilation
0.00
0.00
0.00
0.0%
Water Heating
29.58
29.58
0.00
0.0%
Photovoltaic Offset
—
0.00
0.00
—
Compliance Energy Total
219.96
218.90
1.06
0.6%
Registration Number:
Registration Date/Time:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-09-2416:05:20
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: 52731 Avenida Bermudas Calculation Date/Time: 16:04, Thu, Sep 24, 2015 Page 2 of 7
Calculation Description: Title 24 Analysis Input File Name: 52731 Avenida Bermudas.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
NO SPECIAL FEATURES REQUIRED
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Bulldingdevel Verifications:
• —None —
Cooling System Verifications:
• —None --
HVAC Distribution System Verifications:
• — None —
Domestic Hot Water System Verifications:
• —None —
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTOVtf2-yr)* 296.03 293.97 1.06 0.4%
• Includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01 02 03 04 06
06
07
Number of Dwelling
Project Name Conditioned Floor Area (ft2) Units Number of Bedrooms Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
52731 Avenida Bermudas 800 1 2 1
0
1
ZONE INFORMATION
01 02 03
04
05 06 07
Zone Name Zone Type HVAC System Name
Zone Floor Area
(fit")
Avg, Calling
Height Water Heating System 1 Water Heating System 2
Existing Conditioned HVAC Systeml
800
9 DHW Sys 1
Registration Number:
Registration Date/Time:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-09-2416:05:20
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 52731 Avenida Bermudas Calculation Datef ime: 16:04, Thu, Sep 24, 2015
Calculation Description: Title 24 Analysis Input File Name: 52731 Avenida Bermudas.xml
CF1R-PRF-01
Page 3 of 7
OPAQUE SURFACES
01 02
03
04
06 06 07 08 09 10
Radiant Statu Verified Existing
Name Construction
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ftz)
Window & Door
Area (f:2)
Tilt
(deg)
Status
Verified
Existing
Condition
Ri/N
Existing
R-13 Wall
0
Right
200
24
90
Existing
No
Re/W
Existing
R-13 Wall
270
Batik
257
42.7
90
Existing
No
Le/S
Existing
R-13 Wall
180
Left
200
8
90
Existing
No
Fr/E
Existing
R-13 Wall
90
Front
257
62
90
Existing
No
Roof
Existing
R-00 Roof Attic
Re/W (Back -270) -
- 1
400
0.34
0.31
Existing
No
Root 2
Existing
R-30 Roof Attic
- 1
8.0
400
0.34
Insect Screen (default)
Existing
No
ATTIC
01 02
03
04
06 06 07 08 09 10
Radiant Statu Verified Existing
Name Construction
Type
Roof Rise
Roof Reflectance Roof Emlttance Barrier Cool Roof a Condition
Attic Existing Attic RoofExisting
Ventilated
3
0.1 0.85 No No Enr9 No
11
Name
Surface (Orientation -Azimuth) Width(ft)
Multiplle
Height (ft) r
WINDOWS
01
02 03
04 06
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth) Width(ft)
Multiplle
Height (ft) r
Area (ftz)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
4040 XO
Ri/N (Right -0) -
- 1
16.0
0.34
0.31
Insect Screen (default)
Altered
N/A
2040 SH
RUN (Right -0) -
- 1
8.0
0.34
0.31
Insect Screen (default)
Altered
N/A
2040 SH 2
Re/W (Back -270) -
- 1
8.0
0.34
0.31
Insect Screen (default)
Altered
N/A
2030 SH
Re/W (Back -270) -
- 1
6.0
0.34
0.31
Insect Screen (default)
Altered
N/A
2668 Or w/Half Glass
Re/W (Back -270) -
- 1
16.7
0.40
0.40
Insect Screen (default)
Altered
N/A
3040 XO
Re/W (Back -270) -
- 1
12.0
0.34
0.31
Insect Screen (default)
Altered
N/A
4020 FIX
Le/S (Left -180) -
- 1
8.0
0.33
0.34
Insect Screen (default)
Altered
N/A
3036 Fix
Fr/E (Front -90) -
- 1
10.5
0.34
0.31
Insect Screen (default)
Altered
N/A
6036 XO
Fr/E (Front -90)-
- 1
21.0
1.04
0.76
Insect Screen (default)
Existing
No
3036 XO
Fr/E (Front -90) -
- 1
10.5
1.04
0.76
Insect Screen (default) I
Existing
No
Registration Number:
Registration Date/rime:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFSR-08252015-744
HERS Provider:
Report Generated at: 2015-09-2416:05:20
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 52731 Avenida Bermudas Calculation Date/Time: 16:04, Thu, Sep 24, 2015
Calculation Description: Title 24 Analysis Input File Name: 52731 Avenida Bermudas.xml
CF1R-PRF-01
Page 4 of 7
DOORS
01 02 03 04 106 J 06
Name Side of Building Area (ft=) U -factor Status Verified Existing Condition
3068 Fr/E 20.0 0.50 Existing No
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
06
06
07
08
09
Name
Zone
Total Cavity
Winter Design
Edge Insul. R -value
Construction Name
Surface Type
Construction Type
Framing
R -value
. U -value
Assembly Layers
0.1
None
0.8
No
Existing
No
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck.- IAbod Siding/sheathing/decidng
Attic RoofExisting
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
Cavity/Frame: R -13/2x4
Exterior Finish: 14bod
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.095
Siding/sheathing/deddng
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1/2(4
R-30 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 30
0.032
Over Floor Joists: R-20.9 insul.
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft2)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Slab -on -Grade
Existing
800
0.1
None
0.8
No
Existing
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (011) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required —
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
Annual
Existing
No
Registration Number:
Registration Date/rime:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-09-2416:05:20
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 52731 Avenida Bermudas Calculation DateMme: 16:04, Thu, Sep 24, 2015
Calculation Description: Title 24 Analysis Input File Name: 52731 Avenida Bermudas.xml
CF1R-PRF-01
Page 6 of 7
WATER HEATERS
01
02
01 02
03 04 06 06
07
01
02 03
04
05
06 07
08
Name
Heater Element Type Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Tank Exterior
Input Rating Insulation R -value
1
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas Small Storage
50
0.525 EF
28000-Btu/hr 0
0
WATER HEATING - HERS VERIFICATION
01
02
01 02
03 04 06 06
07
Name Pipe Insulation
Recirculation with
Parallel Piping Compact Distribution Point -of Use Manual Control
Recirculation with
Sensor Control
DHW Sys 1 n/a
n/a n/a n/a n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
08
Multi -speed
Heating System
Cooling System
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
11.5
13
Distribution
Fan
Floor Area
Verified Existing
Name
System Type
Name Ducted
Name Ducted
System
System
Served
Status
Condition
HVAC Systeml
Other Heating and
Heating
Yes
Cooling
I
Yes
Air Distribution
HVAC Fan
800
Existing
No
Cooling System
Component 1
Component 1
System 1
1
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntriFurnace - Fuel -fired central furnace 78 AFUE
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
Efficiency
Multi -speed
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
11.5
13
No
No
N/A
system
Registration Number:
Registration Date/Tlme:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015.744
HERS Provider:
Report Generated at: 2015-09-2416:05:20
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 52731 Avenida Bermudas Calculation DateMme: 16:04, Thu, Sep 24, 2015
Calculation Description: Title 24 Analysis Input File Name: 52731 Avenida Bermudas.xml
CF1 R -PRF -01
Page 6 of 7
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
06
06
07
08
08 10
Insulation
Supply Duct
Return Duct
Verified Existing HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Dud
Status
Condition Verification
Air Distribution
Ducts located in attic
Existing (not
6.0
Attic
Attic
None
Existing
No N/A
System 1
specified)
HVAC DISTRIBUTION - HERS VERIFICATION
01
02 03 04 06 1 06
Name
Dud Leakage Dud Leakage Verified Dud Design
Verification Target (%) Verified Dud Location Return Supply
Air Distribution System 1 -hers -dist
N/A — — — I—
IAO (Indoor Air Quality) FANS
01 02 03 04 06
Name IAQ CFM IAO Fan Type IAO Recovery Effectiveness(%) HERS Verification
SFam IAQVenlRpt 0 Default 0 Not Required
Registration Number:
Registration Date/Time:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-09-2416:05:20
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 52731 Avenida Bermudas Calculation DateMme: 16:04, Thu, Sep 24, 2015
Calculation Description: Title 24 Analysis Input File Name: 52731 Avenida Bermudas.xml
CF1 R -PRF -01
Page 7 of 7
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: -
Documentation Author Signature:
Santiago Lopez-Ocampo
Company:
Signature Date:
Santiago Lopez-Ocampo
9/24/2015
Address:
CEA/HERS Certification Identification (If applicable):
P.O. Box 1018
city/slatIN Quinta, Ca 92247
Phone: 760.485.8927
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations. .
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Company:
Date Signed:
Lucas Coronel
Address:
License:
77935 Calle Tampico
City/State/zip:
Phone:
La Quinta, Ca 92253
760.564.7514
Registration Number:
Registration Date/rime:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-08252015-744
HERS Provider:
Report Generated at: 2015-09-2416:05:20
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Luisa Lopez
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
9/24/2015
Project Address
52731 Avenida Bermudas
La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
800
Addition
0
# of Units
1
INSULATION
Construction Type
Area
Cavi(ft) Special Features Status
Slab Unheated Slab -on -Grade
- no insulation 800 Perim = 0' Existing
Wall Wood Framed
R 13 777 Existing
Door Opaque Door
- no insulation 20 Existing
Roof Wood Framed Attic
R 30 800 Existing
FENESTRATION
Orientation Area ft2
I Total Area: 117 Glazing Percentage: 14.6 % New/Altered Average U -Factor. 0.35
U -Fac SHGC Overhang Sidefins Exterior Shades Status
Right (N) 16.0
0.340
0.31 none none Bug Screen Altered
Right (N) 8.0
0.340
0.31 none none Bug Screen Altered
Rear (VL9 14.0
0.340
0.31 none none Bug Screen Altered
Rear (tM 16.7
0.400
0.40 none none Bug Screen Altered
Rear (W) 12.0
0.340
0.31 none none Bug Screen Altered
Left (S) 8.0
0.330
0.34 none none Bug Screen Altered
Front (E) 10.5
0.340
0.31 none none Bug Screen Altered
Front (E) 31.5
1.040
0.76 none none Bug Screen Existing
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace
78% AFUE
Split Air Conditioner 13.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
HVAC System Ducted
Ducted Attic 6.0
Existing
WATER HEATING .
Qty. Type
Gallons Min. Eff Distribution Status
EnergyPro 6.7 by EnemvSoft User Number: 5732
Run Code: 2015.09-24716:05.53 ID: L 092415
Pae 10 of 15
2.013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§ 110.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets therequirements of § 10-111 (a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar ieflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CFIR.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§150.0(g)l:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class 11
§150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class 11 vapor retarder shall be placed over the earth floor of
§ 150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
§ 150.0(q):
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)IB:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§150.0(e)IC:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
and spa heaters.
§150.0(h)l:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§150.00)1A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§ 150.00)1B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§I50.00)2C:
Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5.
§150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSUSMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§150.0(m)l;
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 'A inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§1!50.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ 150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§150.0(m)13:
space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_: 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2,013 Low -Rise Residential Mandatory Measures Summary
§110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§I 10.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§150.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-13, as applicable.
§150.0(k)IB:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§150.0(k)IC:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§150.0(k)ID:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ I50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §150.0(k).
§150.0(k)2F:
Lighting controls comply with applicable requirements of §110.9.
An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if. it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (FMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if. it
§ 150.0(k)2H:
functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements
of 130.5; and all other requirements in §150.0(k)2.
§ 150.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in §150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ 150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
L Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the followin methods:
.40
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§I50.0(k)9B:
following requirements:
i. Shall comply with §150.0(k)9A; or
ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§ I50.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4 § 140.7 and § 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§150.0(k)10:
Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ I50.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9, § 130.0 § 130.1 § 130.4, § 140.6, and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ 150.0(k)12B:
i. Comply with the applicable requirements in § 110.9, § 130.0, § 130. 1, § 140.6 and § 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10 b through 110.10(e).
§110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§110.10(b)l:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§1 10.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§110.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric'.
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Luisa Lopez
Date
9/24/2015
System Name
HVAC System
Floor Area
800
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation F
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL
CFM
669
0
COOLING PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 80,000
12,808
900 231
8,802
Total Output Btuh 80,000
0
Output Btuh/s ft 100.0
874
508
Cooling System
0
0
Output per System 1
0
0 0
0
Total Output Btuh 1
0
1 874
1 14,556 900
0
Total Output Tons 0.0
508
Total Output Btuh/s ft 0.0
Total Output (S-ft/Ton 9,600,000.0
9,818
Air System
CFM per System
0
HVAC EQUIPMENT SELECTION
Airflow cfm
0
Standard Fau/AC
1 0
80,000
Airflow cfm/s ft 0.00
Airflow cfm/Ton 0.0
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
1 0 80,000
Aug 3 PM Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air -4r
0 cfm
67 OF
67 OF 105 OF
M
Heating Coil
104 OF
+wn
ROOM
68 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F
Outside Air
0 cfm
77/63°F
77/63°F 55/54°F
Cooling Coil
_II
57 55 0
48.5% Roots
75/62°F
EnergyPro 6.7 by EnergySoft