Loading...
BMCH2016-001778-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 c&tit 4 4 Q" COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BMCH2O16-0017 Property Address: 54385 AVENIDA CARRANZA +APN: 774242017 Application Description: MEADOWS / 14SEER/80AFUE Property Zoning: Application Valuation: $6,500.00 Applicant: SUPERIOR HEATING & AIR CONDITIONING INC 73510 30TH AVENUE THOUSAND PALMS, CA 92276 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: 20_/ License No.: 990826 A' /// //.�aDate: �/ 4l/ A( Contractor: /)/(1%� ZA2 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicantfor a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: I 11, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (__j I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I ) I am exempt under Sec. _ . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's ii VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/9/2016 Owner: LINDA MEADOWS 54385 AVENIDA CARRANZA LA QUINTA, CA 92253 Contractor: SUPERIOR HEATING & AIR CONDITIONING INC 73510 30TH AVENUE THOUSAND PALMS, CA 92276 (760)250-0694 Llc. No.: 990826 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and polity number are: Carrier: Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation. laws of California, and agree that, if I ould become subject to the workers' compensation rovisions of Section 3700 he Labor Cod , sh II f rthw'th comply with th le pr isions. Date: Applicant: WARNIN :FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state tlAave' themation is correct. I agree to comply with all city and county ordinanclating buildingconstruction, and reby authorize representatives up eabove-mentia pro erty for inspection purposesDate: Signature (Applicant or A FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY., AMOUNT . , -PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 2/9/16 PAID BY METHOD RECEIPT.# CHECK# CLTD. BY SUPERIOR HEATING & AIR CONDITI CASH R12717 SKH 'Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00 DESCRIPTION ACCOUNT QTY AMOUNT. PA16 PAID DATE. HVAC CHANGEOUT - PACKAGED UNIT 101-0000-42402 0 $36.26 $36.26 2/9/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUPERIOR HEATING & AIR CONDITI CASH R12717 SKH DESCRIPTION ACCOUNT. QTY AMOUNT PAID PAID DATE HVAC CHANGEOUT - PACKAGED UNIT PC 101-0000-42600 0 $24.17 $24.17 2/9/16 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUPERIOR HEATING & AIR CONDITI CASH R12717 SKH Total Paid for CHANGEOUT: $60.43 $60.43 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $91.85 2/9/16 PAID BY 'METHOD RECEIPT.# CHECK # CLTD BY SUPERIOR HEATING & AIR CONDITI CASH R12717 SKH Total Paid for PERMIT ISSUANCE: $91.85 $91.85 TOTALS: Permit Details PERMIT NUMBER City of la Quinta BMCH2O1�6'�001�7 Description: MEADOWS / 14SEER/80AFUE CONDITIONS Type: MECHANICAL Subtype: Status: ISSUED Applied: 2/9/2016 SKH Approved: 2/9/2016 SKH Parcel No: 774242017 Site Address: 54385 AVENIDA CARRANZA LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 287 Lot: 7 Issued: 2/9/2016 SKH UNIT 26 NAME ADDRESSI Lot Sq Ft: 0. Building Sq Ft: 0 Zoning: Finaled: Valuation: $6,500.00 Occupancy Type: Construction Type: Expired: 8/7/2016 SKH No. Buildings: 0 No. Stories: 0 No. Unites: 0 THOUSAND CA PALMS Details: HVAC CHANGE OUT - 14SEER/80AFUE SYSTEM [2013 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2013 CALIFORNIA BUILDING CODES. . V? CHRONOLOGY CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT SUPERIOR HEATING & AIR CONDITIONING INC 73510 30TH AVENUE THOUSAND CA PALMS 92276 (951)660-9619 CONTRACTOR SUPERIOR HEATING & AIR CONDITIONING INC 73510 30TH AVENUE THOUSAND CA PALMS 92276 (951)660-9619 OWNER LINDA MEADOWS 54385 AVENIDA CARRANZA LA QUINTA CA 92253 (951)660-9619 Printed: Tuesday, February 09, 2016 11:09:36 AM 1 of 2 Cff?w.1YS7EMS Printed: Tuesday, February 09, 2016 11:09:36 AM 2 of 2 0ri SYSTEiMS CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS 581473 FEE 101-0000-20306 0 $1.00 $1.00 2/9/16 R12717 CASH SUPERIOR HEATING & SKH AIR CONDITI Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: HVAC CHANGEOUT - 101-0000-42402 0 $36.26 $36.26 2/9/16 R12717 CASH SUPERIOR HEATING & SKH PACKAGED UNIT AIR CONDITI HVAC CHANGEOUT - 101-0000-42600 0 $24.17 $24.17 2/9/16 R12717 CASH SUPERIOR HEATING & SKH PACKAGED UNIT PC AIR CONDITI Total Paid for CHANGEOUT:. $60.43 $60.43 PERMIT ISSUANCE 101-0000-424040 $91.85 $91.85 2/9/16 R12717 CASH SUPERIOR HEATING & SKH AIR CONDITI Total Paid for PERMIT ISSUANCE: $91.85 $91.85 TOTALS: Printed: Tuesday, February 09, 2016 11:09:36 AM 2 of 2 0ri SYSTEiMS Bin # City of La Quinta . Building U Safety Division 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: Owner's Name: G A. P. Number: Address: Legal Description: City, ST, Zip: Z, Z��3 Contract • r o. 'L Telephone: P Address: l!� r_i5_/O Project Description: City, ST, Zip: ` Tel h ne• 6 TePo . Q State Lic. # : 90 City Lic. #•. Arch., Engr., Designer: qD Address: City, ST, Zip: Telephone: c • Co tructi n Type: Occupancy: State Lic. �circle one : New Add'n Alter Repair air DemoProJecttYPe Name,of-Contact Person: Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: --ZSa — 04r, % e,4 Estimated Value of Project ' - O 0 APPLICANT: DO NOT WRITE BELOW THIS LINE N Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance. Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2qd Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.i. H.O.A. Approval Plans resubmitted Grading IN ROUSE:- '"' Reyiew, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, Total Permit Fees CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 2 of 3 ) D. Altered Space Conditioning System (Sections 150.2(b)lE and F) O1 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Dud Length R -Value Central All new Central All new Less than or System 1 packaged HP heating AFUE 80.00 packaged HP cooling SEER 14 Setback equal to 40 R-8 components components feet Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems Ducts and Fans -Duct insulation requirement for new plenums: R6. CF2R-MCH-20-H & CF3R-MCH-20-H — Duct Leakage testing required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced. -Leakage rate compliance::5 15%, or 510% leakage to outside, or seal all accessible leaks. CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge Verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow >_ 300 CFM/tori required when MCH -25 is required. Exceptions: -Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing requirements. -Heating-only systems and Air Handler/Furnace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MECH-25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements. Registration Number: 316-A10200416-000000000-0000 Registration Date/Time: 2016-02-09 09:34:35 HERS Provider: USERA CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016-02-09 09:36:32 Crhorria Vprcinn• n.SSSSr) ) CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-lR-ALT-HVAC) (Page 3 of 3 ) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Shawn Malette Documentation Author Signature: �• /C� Signature Date:. Company: Superior Heating and Air Conditioning, Inc. 2016-02-09 Address: CEA/ HERS Certification Identification (if applicable): 73510 30TH Ave. 990826 City/State/Zip: Phone: THOUSAND PALMS CA 92276 760-250-0694 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensarethat a registe d!copy of this-Ceitificate4of Compliance -shall -be, made available with the building permit(s) issued.for the building, and made available to the enforcement agency for all applicable �ut...� �°i. '. �-', '•+rw�i'Y'••••.."�P1 �Si inspecUonF I•u�nderstand thata regisktered.eopyof thhis ertificat& of"Compliance s ret uiretl to-beJndUded with the do^umentaUon the builder provides to the building owner at occupancy. Responsible Designer Name: _ ; �' x•a ,g Responsible Desigtief Signature: / •Sha►✓ro /yaGerre Shawn Malette a'` Company : —d ti Date Signed Wit,. Superior Heating a Ai . �o�nditipning n by 201 '02 093 ,d r Address: a 73510 30TH Ave. U.S. EnergyRa License: fmAssociatio'n City/State/Zip: Phone: THOUSAND PALMS CA 92276 760-250-0694 Registration Number: 316-A1020041B-000000000-0000 "This digital signature is provided in order to secure .the'content of this registered dbcurnent.,and in no way implies Registration Provider responsibility for .the. accuracy of the information." Registration Date/Time: 2016-02-09 09:34:35 HERS Provider: USERA CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016-02-09 09:36:32 Cr•hpma Vprcinn• n rrrgn ) CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 1 of 3 ) Project Name: L.Meadows I Date Prepared: 2016-02-09 A. General Information MR -ALT -02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one MR -ALT -02 document for each dwelling unit. 01 Project Name L.Meadows 02 Date Prepared 2016-02-09 03 Project Location fj+3a;5 A39.5 -Avenida Carranza 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name House 07 Zip Code 92253 08 Dwelling Unit Conditioned 1811 refrigerant ci ' Installing new S system Installing than 40 Installing Floor Area (ft2) or r or Area �.: this SC. Number of space conditioning containing,--� j E Climate Zone 15 10 (SC) systems in this dwelling 1 Served system? unit. + components?- B. Space Conditioning (SC) System Information 01 02 03 04 05 06 07 08 09 10 Is the Installing a ;. '' SC System Identification `?Location SC System ( ` GFA served:cO by systema ducteii"""' refrigerant ci ' Installing new S system Installing than 40 Installing Installing new or r or Area �.: this SC. 9 w containing,--� j more y_ 4 entirely new entirely Name Served system? component? ^ + components?- v feet of ducts? duct system? SC system? Alteration Type pSysterrm*(ft2). System 1 Ho 81r rt.._,_., Yes. Yes,��Yes '►� No No Altered ,;se ,�No y t i ning s s em conditioning C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)IDiib) Registration Number: 316-A1020041B-000000000-0000 This section does not apply to this project. Registration Date/Time: 2016-02-09 09:34:35 HERS Provider: USERA CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016-02-09 09:36:32 ,rhpma Vprcinri• n rrrcnr)