Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
0372
W.O.# 52448-206 NOTFf.. � With proper validation Q this form constitutes an CITY OF LA QUINTA _ encroachment permit APPLICATION FOR PERMIT PUBLIC WORKS CONSTRUCTION (ENCROACHMENT) c� ''»•� �S�4ti r `SOF TF�9 For, the construction of public or private curbs, driveways, pavements, sidewalks, parking lots, sewers, water mains and other like public works improvements in connection with MINOR IMPROVEMENTS and APPROVED SUBDIVISIONS February 7, - 1989 Subdivision Improvement Permit — Class III DATE: Minor Improvement Permit Class IV X ` LOCATION OF CONSTRUCTION Calle Quito at Avenida Tujunga (Street address or Description of Location) PURPOSE OF CONSTRUCTION TO 1riSta11 100 , Of 2" Sketch (attach construction plans if appropriate) plastic medium pressure gas main, 151 E/WPL of Quito DESCRIPTION OF CONSTRUCTION qrr SKFTrR Trip 01$,E6 CUT -EARTH DIMENSION OF INSTALLATION OR REMOVAL SIZE OF EXCAVATION, IF NEEDED APPROXIMATE TIME WHEN WORK WILL BEGIN ' APPROXIMATE TIME OF COMPLETION ESTIMATED CONSTRUCTION COST $ ' (Including removal of all obstruction, materials, and debris, backfilling, com-- ; paction and placing permanent resurfacing and/or replacing improvements) In consideration of the granting of this permit, the applicant hereby agrees to: t Indemnify, defend and save the City, its authorized agents, officers, representatives and employees, harmless from and against any and all penalties, liabilities or loss resulting from claims or court action and arising out of any accident, loss or damage to persons or property , happening or occurring as a proximate result of any, work undertaken under the permit granted pursuant to this application. Notify the Administrative Authority at least twenty-four (24) hours in advance of the time when work will be started. Comply with all applicable City Ordinances, the terms and conditions of the permit and all applicable rules and regulations of the City of La Quinta and to pay for `any additional replacement necessary as the result of this work. J.M. SNYDER, DISTRIBUTION/0C'JUPERVISOR Signature of Applicant or Agent41 SOUTHERN CALIFORNIA GAS CO. P.O. BOX2200 Riverside, Ca., 92516. Name of Applicant (please print) Business Address Telephone No. Name of Contractor and Job Foreman Business. Address Telephone No. t Contractor's License No. City Business License-No- Applicant's icense No:Applicant's Insurance Company, Policy Number ' FEES: Subdivision Improvement Permit — Class III ' Public improvements: 3% of estimated construction costs , Private improvements: 3% of estimated construction costs , Minor" Improvement Permit — Class IV: See attached schedule 3'7 Inspection -Fie $ NA PERMIT VALIDATION .Permit Fee NA PERMIT NO. 372 IJ Penalty 2/13. / 9 Cash Deposit -Surety Bond DATE APPROVED if, required EXPIRATION DATE 8/1/89 TOTAL: $" '�� DATE ISSUED 2/13I,/8�k Receipt No. ;.,. By Received by Date Administrative Authority Recorded by TELEPHONE: (619) 564-2246 ; t EXCAVATION REPORT - snurHFRN eAl IFn RNIA aAA cn TO: CITY OF LA QUINTA 0 79780 Horseshoe Rd., in west -side of Roadrunn T Ln., 60' N/NPL Horseshoe Rd, O N 4 DATE 6/29/89 PREPARED SIZE OF 6'.x10',- 9'x2' Perm, 3/28/89 WORK ORDER I ORACCOUNT SI EXECUTION U 61532 53400 ORDER NO. KIND 78 sq.ft. Earth. SOUTHERN CALIFORNIA GAS CO. 2865-28 0346. PERMIT NUMBER r i� '\'=EXCAVATION '0346. REPORT- souTHeRNcnuFORNIAGAsco. PERMIT NUMBER • TO: ' CITY 'OF LA' QUINTA 'o 79780 Horseshoe Rd., in west side of R®adrunue " T Ln.,.60' N/NPL Horseshoe Rd 'A 10 r N • J_. f •%` WORK ORDER A COUNT PROD. OR SUB. A CT. ORG. CODE 6/29/89-U 61532 DATE EXECUTION PREPARED ORDER NO. 'KIND SIZE OF CUT - 6'x18', 9'x2' - 78 sq.€t. Earth Perm 3/28/89 J : OUTHERN CALIFORNIA GAS CO.2865.2B i EXCAVATION REPORT:- SOUTHERN CALIFORNIA GAS CO. 7(� TO., t - CITY OF 'INW' L 0 - - 4661-8 Madison St., in`Cristina., 323' W/WEL. Via Louitas O N' - _ WORK ORDER:. PROJ. OR - ORG. ,. . p(� - ORACCOUNT- SUB. ACCT. CODE DATE - OR ER No - U 63722 53400 997 ZA PREPARED-fil 07 - SIZE,OF CUT KIND - 4'x3' Perm 3/24/89 SOUTHERN CALIFORNIA GAS CO. 2865-2B �.1. EXCAVATION REPORT - SOUTHERN CALIFORNIA GAS CO. " ' y' TO: CITY 0V INDO S • PROD. OR '° ::46618 Madison St., in Cristina, 323' W/WPL c << r -A. T. J"O . - - .Via Louitas ' KIND ',( . ..N. ' WORK ORDER tORACCOUNT 61400 rye} 6/2. DATE9I /�� EXECUTION U 63721E PREPARED ORDER NO. `,,• SIZE OF CUT . 4'x31. � .( 12 sq.ft. Earth ( Perm 3/24/89 `SOUTHERN CALIFORNIA GAS CO. 2865-2B PERMIT NUMBE S • PROD. OR ORG. SUB. ACCT. CODE 997 ZA KIND ',( . . 4'x31. � .( 12 sq.ft. Earth ( Perm 3/24/89 `SOUTHERN CALIFORNIA GAS CO. 2865-2B wT��ti oconor _ ononun ins rn TO: i 'CITY OF LA. UINTA t 52391 Avenida Villa; 281' N/CL Calle Ensenad T I .O N + .. DATE Q i PREPARED'6/29/89 EXECUTION U 5642.4 ORDER NO. SIZE OF CUT 55'x2' ,15-'x1.7' , . r. Perm 3/31/89 SOUTHERN CALIFORNIA GAS CO. 2865-213 0346 PERMIT NUM BE eVVORK ORDER— . OR ACCOUNT SUB. ACCT.' CODE 53448 344 R KIND" ,EXCAVATION REPORT -SOUTHERN CALIFORNIA GAS CO t .0346 PERMITNUMBE t. IWI I OR ACCOUNT SUB. Ac'c'T.CODE L 29/89 U 56424 :$34413 j 44 PREPARED ARED-EXECUTION ORDER NO. SIZE OF CUT K I N 5'x2', 15'x1.7' 36 sq:ft. Perm 3/31/89 SOUTHERN CALIFORNIA GAS CO. 2865-28 CITY OF LA QUtWTA F" L 0 52391 Avenida Villa, 2110 N/CL Calle Eusena& c A T I 0 N .0346 PERMITNUMBE t. IWI I OR ACCOUNT SUB. Ac'c'T.CODE L 29/89 U 56424 :$34413 j 44 PREPARED ARED-EXECUTION ORDER NO. SIZE OF CUT K I N 5'x2', 15'x1.7' 36 sq:ft. Perm 3/31/89 SOUTHERN CALIFORNIA GAS CO. 2865-28 EXCAVATION REPORT - SOUTHERN CALIFORNIA GAS CO. TO: CITY OF LA QUINTA 0 48721 Santa Ursula St..,'275:' S/SPL Eisenhower C A T - O N ' � . OR ACCOUNT DATE 6/29/89.' 'EXECUTION O 77 61610 - PREPAREDORDER NO. 0346 SIZE OF CUT - KIND 5'x2' 10 sq.ft. Earth Perm 4/3/89 SOUTHERN CALIFORNIA GAS CO. 2865-28 ' Vx2`lU 8q.it.. Earth Per9n 4/3/89' -� I - SOUTHERN CALIFORNIA GAS CO: 2865-2B _ 0346 ' EXCAVATION REPORT - SOUTHERN CALIFORNIA GAS CO. d PERMIT NUMBE ro: CITY OF ILA QIII.NTA •• 48721 Saata Ursula St." 27S' S/SPL.Eisenhower o` i' A T 10 4 >t N WORK ORDER": •PROD. OR ORG. 6/29%89 U'61610,, O C OUNT SUB. ACCT. CODE DATE: • EXECUTION PREPARED `ORDER NO. • - - SIZE OF CUT -KIND ` Vx2`lU 8q.it.. Earth Per9n 4/3/89' -� I - SOUTHERN CALIFORNIA GAS CO: 2865-2B _ FYP_AVATInN RIF PORT - iouTH FRN GAl IFn RNIA GAS CO. TO: CITY OF. LA UINTA C 51905 Eisenhower Dr., 195' N/NPL Calle:Duran .A. T _ O N ' DATE . 29/89 EXECUTION PREPARED6/U 57298 ORDER NO. SIZE OF CUT 5=x2.', 25'x2' Perm 4/17/89: SOUTHERN CALIFORNIA GAS CO. 2865-28 60 sq.f.t. 0346 PERMIT NUMBED 9 ACCOUNT SUB.ACCT. I CODE 53400 997 ZA KIND N', Vd- A V A+11"%Kl 92F: Pn RT- Q^i MW PON r -Al I—ONIA r-Aq en Im TO: -CITY OF, LA: QUINT® 0 51905 Eisenhower Dr., .195"N/NPL Calle Dwrang C A T 0 N 0346 PERMIT NUMBER - OR ACCOUNT SUB. ACCT. CODE kEXECUTION 57296 DAT. D T. 6/29/89 r REP�R_ORDqR NO. , SIZE OF CUT KIND 1 CE�rth 25 1 x2f 60 sq. f t. Perti 4/17/89 �SOUTHERN CALIFORNIA.GAS CO. 2865-2B - CYP• A%I Ariewu oConor _ e Gec e'•n To: . CITY 'OFLA QUINTA L C - .. 52420 Avenida Navarro, 221' N/CL Calle,Ense A T O N DATE PREPARED U/ "9189'. EXECUTION U 66767 ORDER NO. SIZE OF CUT . 5''x2.5' L Perm 5/8%89 ALIFORNIA'GAS CO. 2865-2B' 1'3 sq. ft. 0346 PERMITNUMBE ada OR ACCOUNT SUB. ACCT 53400 1 99 KIND Earth DE !I EXCAVATION REPORT - SOUTHERN CALIFORNIA GAS CO TO: 4ITY OYLA QUINTA Ml\NU�MBEJJ I OR ACCOUNT I SUB. ACCT. I e&jE I DATE 6EXECUTION U 66767 534UU VY/1 41 PREORDER NO. SIZE OF CUT KIND - st x21'13 sq, f t. Earth 5 Perm 5/81c'8 9" SOUTHERN CALIFORNIA GASCO. 2865-2B '0 L Avenida Navarro, 2211 N/CL Calle Ensdn C A, T' .52420 0' N' Ml\NU�MBEJJ I OR ACCOUNT I SUB. ACCT. I e&jE I DATE 6EXECUTION U 66767 534UU VY/1 41 PREORDER NO. SIZE OF CUT KIND - st x21'13 sq, f t. Earth 5 Perm 5/81c'8 9" SOUTHERN CALIFORNIA GASCO. 2865-2B FYf'AVATInFWRFPORT- SOIITMFRN CALIFORNIA GAS.CO. Tom' CITY :OF LA• QUINTA , 52435 Eisenhower, 86' N/CL Calle'Ensenada ' A r .. O .N •� , a - 0346 PERMIT NUMBER - WVKK VKUtK YKVJ. VK VKG. 77 OR ACCOUNT SUB. ACCT. CODE - DATE - 6/29/H9 - EXECUTION, U 6HH45 'S• - - PREPARED ORDER NO. 53400 ,777 ZA SIZE OF CUT KIND 6'x5.5', 25:x2' 83 sq.ft.- ,Earth Perm 5/3'/89 . . SOUTHERN CALIFORNIA GAS CO. -2865-28 - �. .Y ;4EXCAVATI6N RE II' N a� SOUTrHERN CALIFORNIA GAS CO. 'TO: ,CITY .,OF LA QUINTA_' .- - 14 C 52435 Eisenhower, 86' N/CL Ca11e:Ens©nada` A T r ' WORK ORDER PROD. OH - ORG. `1� OR ACCOUNT SUB. ACCT. CODE• ,PREPARED •6/29/89 - ' XECUT16N. .U..•6994-5 .., ORDER 53400 x.997 ZA SIZE OF CUT KIND ~" 6x5.5', 25'x2', 89 sq.ft. Earth 'i / 3 perm 5/3 89 ' SOUTH E RN CALI FO RNIA GAS CO. 2865.28 , FYG Av&T1AtJ RFPs RT - snuTw PGN cna iP[1RmA cans en_ TO: - .. . CI* 'OF LA QUINTA ° 51480 Avenida Villa, north side of Hidalgo, T 1131..E/CL Avenida Villa O N DATE ��29/89 _,EXECUTION U57704 PREPARE ORDER NO. SIZE OF CUT 5'x2' Perm 5%19/89 SOUTHERN CALIFORNIA GAS CO. 2865-2B 10 S4.1 t. 0346 PERMIT NUMBER • OR ACCOUNT SUB. ACCT.1 ODE 53400 996, KA' KIND Earth • FYf AV ATIAIJ PFPnPT - GOIITMFRN f_AI IFORNIA GAS CO. TO: G.ITY . 0� • LA QUINTA L 52307.'"AVenida Vallejo, 301' N/NPL Ensenada 0 C A T O N 34 , PERMIT NUMBER '�`�, " OR ACCOUNT I SUB. ACCT. CODE PDATE EX REPARED 6/29/89 ORDERECUTION O. f U" 43428 51248 - 56t. SIZE OF CUT KIND 4'x2 8 sq.ft. 6" Mac Perm. repair made on P.R:O.`4262 2/16/89 ` x SOUTHERN CALIFORNIA GAS CO. 2865-28 - 0 �. 4-+ e 11y a IIIIIIIII! EXCAVATION REPOL To:... CiTt OP 'LA QUINTA' t' ` 4 0 51480 Avenida 'Villa, north side ©f,Hldalgo,; C. • 113' E/CL, Avenida Villa sr. I .N is . C ,tI •tti DATE 6/29/89 EXECUTION U 57704 PREPARED _ ORDER NO. - ' - SIZE OF CUT 51x2' 10 eq.ft. Pvrm' 5/19/89 1 SOUTHERN CALIFORNIA GAS.CO. 2865-2B 0346 PERMIT 4�t OR A�SUB. ACCT. CC KIND Earth r`� f 334 EXCAVATION REPORT -:SOUTHERN CALIFORNIA GAS CO. .. ci :Ofp y A QUINT JPERMIT NUMBER I, 52307 Avehida..Va a o, nsena a L k �} .O 'A .. yyyyf T WORK ORDER PROD. OR ORG:-.i. OR ACCOUNT SUB. ACCT. CODE 7' 'i EXECUTION V- 43428 - .7i7: PREPAREDORDER NO. fO A- ! ,. SIZE OF CUT KIND ` L��tf . 4x2-' 8 sq.ft,: t Pe`rm. repair made on P:R.O. °4262 Y. t:..; 2/36/89 'SO UTHERN CALIFORNIA GAS CO. 2665-28 - NEXCAVATION REPORT - SOUTHERN CALIFORNIA GAS CO. T 0: CITY OF 'LA QUINTA ' o x :51580 Avenida Villa, 242' S/SPL;-Calle Hidalgo C A T .. O N 0346 PERMIT NUMBE u M wVnn Vnunn YItV J. Vtt Vfib. ORACCOUNT SUB. ACCT. CODE °ATE 6/29/89 EXECUTION U 57325 53400 996 1 KA PREPARED ORDER NO. SIZE OF CUT KIND ' 10'x1.5' 15 sq,.ft Earth w Perm 3/17/89., SOUTHERN CALIFORNIA GAS CO:286S-2B D TO: ' CITY OF LA QUINTA 0 78610 Bottlebrush Dr.., 512' E/EPL Washington S C A , T ORG. I O N CODEKA p I- OR NS ACCOUT DATE 6/29/89 'EXECUTION U57978 PREPARED ORDER NO. SIZE'OF CUT 15'x1.5' 23 sq.ft. KIND 0346 , PERMIT NUMBER • , 'ROJ. OR ORG. is. ACCT. CODEKA U13 , Earth Perm 3/17/89 SOUTHERN CALIFORNIA GAS CO. 2865-2B - '. 'EXCAVATION REPORT' -.SOUTHERN CALIFORNIA cnS CO. DATE?' % 6/43,/87 + EXECUTION' U57978 ' `. •PREPARED ORDER NO. SIZE OF GUT 0346 11 ' KIND - • 2�, sq.ft. Earth y. -4 is Perm 3/17/89-, I. SOUTHERN CALIFORNIA GAS CO. 2865-28 + CITY- OF LA QUI14TA ' .0::-,78610..Bottlebrush'8r., 512' E/EPL!`Washington 3 r .A 77 - 3 1 0. N !' DATE?' % 6/43,/87 + EXECUTION' U57978 ' `. •PREPARED ORDER NO. SIZE OF GUT 0346 11 ' KIND - • 2�, sq.ft. Earth y. -4 is Perm 3/17/89-, I. SOUTHERN CALIFORNIA GAS CO. 2865-28 + EXCAVATION REPORT - SOUTHERN CALIFORNIA GAS CO. 0346. TO: .CITY IOF LA'QUINTA CITy, �le L*51580 0 . Avenida Villa, 242' S/SPL Calle Hidaii1go I A ..-T EXECUTON ORDER 00.. U 57325 0 N 996. WORKORDER, _ORACCOUNT 'PROJ. OR SUB. ACCT. ORG. CODE DATE., PREPARED 6/29/89 EXECUTON ORDER 00.. U 57325 53400' 996. KA, • SIZE.OF CUT KIND 10lx1.51. 15 84.¢t E'aith Penin erin j/17/89 .'SOUTHERN CALIFORNIA GAS CO. 2865-B 2 La��Q• _moo • -:. ��� 5 OF rrtE78_105 CALLE ` ESTADO - LA QUINTA, CALIFORNIA 92253 - (619) 564-2246 FAX (619) 564-5617 November 21,`.1989 .Southern California Gas Co P.O. Box 2200 Riverside, California •92516 Re: Encroachment Permit -NO. -372 Gentlemen: The City. of.. La Quinta hereby. grants ;Southern California Gas Company a time extension for encroachment permit# 372, for installation of 100', of 2" plastic medium.. pressure gas main. on Calle Quito at Avenida Tujunga. The new expiration date will be December 15; 1989. If the work,is to be Performed by forces other than that t of ,:Southern California Gas Co.;_theri.that contracting company will be required to apply for an additional` encroachment permit and pay -the appropriate inspection fee. Please notify, ':the City, 24 hours in .advance .of the time when work will start. If you.have any 'further questions please don't hesitate to contact me. Very truly yours,. Sharon Harris Engineering Secretary _ cc: Michael Hudson,'Public Works Inspector \ Encroachment permit #372 file. jr MAILING ADDRESS P.O. BOX l'iO4 LA QUINTA,,CALIFORNIA 92253 W.O. #- 53448-206 . NOTI�: • • With proper validation 2 this form constitutes an encroachment permit CITY• OF - L•A QUINTA APPLICATION FOR PERMIT, -- PUBLIC WORKS CONSTRUCTION '(ENCROACHMENT)c� �wS�4ti 'SOF TH8 For the construction of 'public -or private curbs,' driveways, pavements, sidewalks, parking lots, sewers, water mains and other. like public works improvements -in connection with,MINOR IMPROVEMENTS and APPROVED SUBDIVISIONS February 7 '1989 -Subdivision,Improvement Permit —Class. I I I ' DATE: ` - Minor Improvement Permit Class IV XF LOCATION OF CONSTRUCTION Calle Quito . at Avenida TuJunga (Street address or Description of Location) PURPOSE OF'CQNSTRUCTION To install 100" of 2"Sketch (attach construction plans if appropriate) plastic medium,pressure gas main, 5 E WPL of;Qu to DESCRIPTION OF CONSTRUCTION SEP, SKFTCH TGP 21 4, E6 CUT -EARTH, DIMENSION OF INSTALLATION'OR REMOVAL ` SIZE,OF EXCAVATION; IF NEEDED • , r -f APPROXIMATE TIME WHEN WORK WILL,BEGIN APPROXIMATE TIME OF COMPLETION } "• - ESTIMATED CONSTRUCTION COST $ - a (Including removal of all obstruction, materials, and debris, backfilling, com- paction and placing permanent resurfacing and/or replacing improvements) In consideration of the granting of this permit, the applicant hereby agrees to: Indemnify, -defend and 'save the City, its authorized agents, officers, representatives and employees, harmless from and against any and all penalties, liabilities or loss resulting from claims or court action.and-arising out of any accident, loss or damage to persons or property happening or occurring as•a proximate result of any work undertaken under the permit granted pursuant to this application. - Notify the Administrative Authority at'least twenty-four (24) hours in advance of the time when work will be started. Comply with all applicable'City Ordinances, the terms and conditions of the permit'and all applicable rules and regulations of the City,of La Ouinta and to pay for any additional replacement necessary as the result of this work. •J.M. SNYDER, DISTRIBUTION SUPERVISOR Signature of Applicant or Agent SOUTHERN' CALIFORNIA, GAS CO'. P.O. BOX2200 Riverside; Ca. `,92516 Name of Applicant (please print) '. Business Address Telephone No.. Name of Contractor and Job Foreman Business Address * Telephone No. Contractor's License No. • City Business License No. , Applicant's Insurance Company, Policy Number FEES: Subdivision Improvement Permit — Class I II Public improvements: 3% of estimated construction costs Private improvements: 3% of estimated construction costs ' 0 Minor Improvement Permit — Class`IV: See attached schedule N r " • 372 72 Inspection Fee $ NA y r PERMIT VALIDATION Permit Fee NA . PERMIT NO. 372 Penalty 2 / 13/8 9 Cash Deposit -Surety Bond - DATE APPROVED if required - EXPIRATION DATE 8/ - /89 TOTAL: $-" =0= DATE ISSUED 2/13/89 . Receipt No.By Received by Date Administrative Authority Recorded by- ' TELEPHONE: (619) 564-2246 - W.0.#53448-206-----•—•------------�----------- NOTE: With proper validation this form constitutes an CITY OF LA OUINTA encroachment permit APPLICATION FOR PERMIT PUBLIC WORKS CONSTRUCTION (ENCROACHMENT) ;For .the construction of public or private curbs, driveways, pavements, sidewalks, parking lots, sewers, water mains and other like public works improvements in connection with MINOR IMPROVEMENTS and APPROVED SUBDIVISIONS ! v . February 7, 1989 Subdivision Improvement Permit - Class III GATE: Minor Improvement Permit Class IV LOCATION OF CONSTRUCTION - Calle Quito at Avenida Tuiunga Istreat address or Description of Location) PUPPOSE OF CONSTRUCTION To install 100' of 2" plastic Sketch (attach construction plans if appropriate) me ium pressure gas main, o a e uito. DESCRIPTION OF CONSTRUCTION SEE SKETCH TGP 214,E6 CUT -EARTH DIMENSION OF INSTALLATION OR REMOVAL SIZE OF EXCAVATION, IF NEEDED APPROXIMATE TIME WHEN WORK WILL BEGIN APPROXIMATE TIME OF COMPLETION ESTIMATED CONSTRUCTION COST $ (Including removal of all obstruction, materials, and debris, backfilling, com- paction and placing permanent resurfacing and/or replacing improvements) In consideration of the granting of this permit, the applicant hereby agrees to: Indemnify, defend and save the City, its authorized agents, officers; representatives and employees, harmless from and against any and all ,penalties, liabilities or lou resulting from claims or court action and arising out of any accident, loss or damage to persons or property happening or occurring as a proximate rewlt of any work undertaken under the permit granted pursuant to this application. Notify the Administrative Authority at least twenty-four 124) hours in advance of the time when work will be started. Comply with all applicable City Ordinances, the terms and conditions of the permit and all applicable rules and regulations of the City of 4A Quints and to pay for any additional replacement necessary as the2jZ%4TR1RUT7()N Signature of Applicant or Agent SOUTHERN CALIFORNIA GAS CO. P -O- Rox 9900 Riyprcidar r'A 499IF 'Name.of Applicant (please print) Business Address Telephone No.i Name of Contractor and Job Foreman Business Address Telephone No. Contractor's License No. r City Business License No. Applicant's Insurance Company Policy Number FEES: Subdivision Improvement Permit Class III Public improvements: 3% of estimated construction costs Private improvements: 3% of estimated construction costs Minor Improvement Permit - Class IV: See attached schedule Inspection Feb S- - Permit Fee Penalty Cash Deposit -Surety Bond if required TOTAL: W. $ w Receipt No. Received by Recorded by Date PERMIT VALIDATION PERMIT NO. 37Z DATE APPROVED EXPIRATION DATE, DATE •ISSUED By. Administrative Authority TELEPHONE: (619) 564.2246 The following General and Special Provisions are attached to and made a part. of Permit.No. A . _ . • . GENERAL PROVISIONS The following shall always'apply`. ENCROACHMENT ON PRIVATE PROPERTY: This permit authorize's'work to be accomplished within City of La Quinta right of way ONLY. Whenever construction extends within private property, it shall be the responsibility of the.permittee (or his contractors)to secure permission from.abutting property owners. Such authorization must,be secured by the permittee prior to starting work. TRACKLAYINGCONSTRUCTION'EQUIPMENT: Cleated tracklayingconstruction equipment shall not bepermitte'dtooperateonany paved surface unless fitted with smooth -faced street pads. All mechanical outriggers shall be fitted with rubber street shoes to protect the paving during excavations. Rubber -tired equipment only shall be used in backfill operations in paved areas. If the existing pavement is scarred, spalled, or broken during the term of this contract, or if the pavement is marred, City of La Quinta shall request that these portions of road be resurfaced over their entire width. Resurfacing shall consist of one coat of two inches (2") of A.C. surfacing plus appropriate seal coat as specified above. PROTECTION OF TRAFFIC: All excavations and work areas shall be properly lighted and barricaded as deemed necessary by the City Engineer or La Quinta City Public Works Inspectors. Suitable detours and detour signs shall be placed and maintained for the duration of the project. The City shall be notified 24 Hrs. in advance of any traffic detours or delineations. CARE OF DRAINAGE STRUCTURES: Any drainage structure including corrugated metal pipe, concrete pipe, steel culvert and concrete structures encountered during excavation which necessitate removal shall be replaced in kind. In the event.it becomes necessary.t'o remove or cut -existing drainage structures, City of La Quinta shall be notified prior to commencement of this`work. Drainage structures and open drains shall be kept free of debris at all times for proper drainage. RIGHT OF WAY CLEANUP: Any surplus material resulting from excavation and backfill operations shall be removed from the right of way. All paved surfaces shall be broomed clean of earth and other objectionable materials immediately after backfill and compaction. Existing gutter line and drainage ditches shall be replaced to their original standard or better. All excess material shall be removed prior to paving. Water tanker shall be used, as required, to sprinkle the job site to keep down dust conditions and shall b' used immediately after backfill. DE -WATER OPERATIONS: If de -watering operations are required and pumps are forcing water on City of La Quinta roads, it shall be the responsibility of the permittee (contractor) to control this water and to provide off-street barricades when necessary. CLOSING STREETS: No street shall be closed. A minimum of one lane of traffic shall be maintained at all times to provide limited - access for the adjoining property owners and emergency vehicles. In the event it is felt bythe permitteethat he must close a streetfor x any length of time, permittee shall contact this office to obtain the necessary permission. SPECIAL PROVISIONS The follwing shall apply ONLY when indicated: R1 NOTIFICATION: Permittee shall notify the City at 564-2246 at least 48 hours in advance of starting construction~ R2 CASH DEPOSITS OR BONDS: A cash bond or an approved surety bond in an amount of not less than $ shall be.furnished in the name of City of La Quinta to cover all work involved in the restoration of the various La Quinta roads and survey monuments. This bond shall be continuous until cancelled.by the?City Engineer. This bond must be posted prior to commencement of any work on this project . SR3 UTILITY CLEARANCE: (Substructures) Priorto making any excavation within the Cityof La Quinta rightof wayauthorized ' by permit, the permittee shall contact all concerned utility companies relative to the location of existing substructures. Damage to existing substructures resulting from operations conducted under this permit shall be the sole responsibility of the permittee. I R4 UTILITY CLEARANCE: (Surface structures) No work shall be done under this permit until all utilities are clear of the proposed work site. The permittee shall notify all concerned utility companies of the proposed work. R5 PAVEMENT WIDENING: Area between the proposed concrete gutter line and the existing road pavement shall be surfaced with inches of A.C. paving placed on inches of class aggregate subbase course having an "R';value of not less than and in conformance with City of La Quinta Road Improvement Standards and Specifications, Ordinance #461. R6 PARKWAY GRADING: Area between the property line and top of the -proposed concrete curb shall be graded to a slope of 1/4 inch to one foot (1'). R7 ,GRADES & STAKES: City of La Quinta shall establish grades and stakes for the proposed concrete curb and gutter construction. R8 GRADE CHECKING: City of La Quinta shall check grades upon receipt of plan and profile and/or grades as established by a licensed.engineer. R9 CURB REMOVAL FOR DRIVEWAYS: A portion of the existing concrete curb and/or curb and gutter ( feet)shall be removed. Curb and/or curb'and gutter shall be saw cut prior to removal. Depressed curb, matching concrete gutter and concrete driveway approach shall be constructed in conformance with City of La Quinta Standard #207. R10 DRIVEWAYS, A.C.: Driveways shall be constructed as not to alter existing drainage pattern. Surfacing between the property line and the existing road paving shall be 2-1/2 inches of A.C. paving placed on ( ") of class aggregate base. Driveway constructionshall conform to attached drawing. R 11 CULVERTS: A - inch diameter ( )culverts ' hall be installed with the invert approximately 1-1 /2 inches below and in line with the existing flow line. Culvert installation shall conform to the attached drawing. R1'2, SIGHT CLEARANCE: -Sight •clearance•of 600 feet in either direction shall be -assured and maintained. R SOIL STERILIZER: The area to be surfaced shall be treated with soil sterilizer. Rate of application shall comply with the manufacturer's specifications. . R14 COORDINATE WORK: The proposed work shall be subordinated to any operation' which the State of California or :City of La Quinta• may' conduct in this:area during -the period of this permit. Work shall be coordinated with the State or City of La Quinta forces to preclude delay or interference with `State or -City of La Quinta projects. R15 SURVEY MONUMENTS: Prior•to excavation or beginning of construction, all survey monuments which exist on the centerline of all streets or property lines when involved shall be completely tied out so they maybe readily and correctly be replaced by a licensed civil engineer or surveyor at the expense of the permittee. A complete set of notes showing the ties to these monuments shall be furnished to•the City Engineer prior to the removal of any monuments. This office shall be' notified upon completion'of'mplacement of all survey monuments for'proper project clearance. R16 SURVEY MONUMENTS: Prio xcavation or beginning of construction, all si , monuments shall betied out by City of La Quinta and suitable payment or guarantee of payment shall be made as reimbursement for all work involved, R17 PAVEMENT CUTTING: Pavement will be mechanically cut to a straight edge prior to excavation. Method of pavement cutting shall be approved through the office of the City Engineer. (Under no circumstances shall excavating equipment be used to excavate prior to cutting of pavement). Excavation material shall be placed in such a position as to best facilitate the general flow of traffic. Prior to final paving operations, any damage to pavement straight edge shall be corrected. R18 PAVEMENT CUTTING: Pavement shall be saw cut prior to removal. Prior to final paving operations, any damage to pavement straight edge shall be corrected. R19 LIMIT OF EXCAVATIONS: Excavations shall be limited to 1,000 lineal feetof opentrench before backfill operations must begin. All excavations shall be properly barricaded with lights overnight, on weekends and holidays for the protection of the traveling public. The Public Works inspector shall determine the suitability of excavation barricading in each case. No excavation shall remain open for a period exceeding five (5) days. No excavation shall be made unless the construction material is actually on the work site. R20 BACKFILL MATERIAL: Backfill shall be free of brush, roots or other organic substance detrimental to its use for purposes of producing an adequately consolidated backfill. Any material which the City of La Quinta deems unsuitable (spongyor saturated material) which is encountered during excavation shall not be used for backfill, but shall be supplemented or replaced by an approved sand or gravel. R21 BACKFILL SAND: Backfill shall be approved transit -mix sand or equivalent and shall be placed in lifts of notgreaterthan three feet (3') and vibrated using vibrotamper or equivalent equipment. Alternate methods maybe substituted, but in any case a relative compaction of 95 percent shall be attained within the structural section of the roadway. R22 BACKFILL PLACEMENT: Backfill shall be applied in layers of not more than 50 percent of the total depth of the trench before flooding or a maximum of five-foot (5') liftswhere trenches are of excessive depths. Care is to be exercised that the backfill material is not subjected to extreme swell by flooding operations. Backfill material shall be placed so that the resulting compaction shall be not less than 90 percent or equivalent to the surrounding ground, whichever is the greater compaction. Where ponding or flooding is used for a maximum settlement, adequate dikes will be constructed to retain the water. Where jetting is used, the jets shall be of sufficient length to reach the bottom of each layer and the water supply shall be continuous. R23 COMPACTION TESTS: If so required bythe inspector, compaction tests shall be made at intervals of not more than 1,000 feet and a minimum of one (1) test on each road. One (1) copy of each test shall be forwarded to the City Engineer for approval and filed prior to making permanent repairs. Compaction tests shall be made as outlined in Section 6.3.01 of the Standard Specifications, Division of Highways, State of California, dated January 1973. R24 COMPACTION TESTS: If so required by the inspector, compaction tests shall be made for each crossing or service line. One (1) copy of each test shall be forwarded to the City Engineer for approval and filed prior to making permanent repairs. Compaction tests shall be made as outlined in Section 6.3.01 of the Standard Specifications, Division of Highways, State of California, dated January 1973. R25 TEMPORARY PAVEMENT REPAIRS: After completion of backfill and compaction operations, a temporary patch consisting of 2 inches of SC -800 shall be placed on a prepared subgrade. The SC -800 temporary paving shall be placed after a maximum of 3,000 lineal feetof trench has been excavated and backfill operations completed, but in no case shall the placement of the temporary pavement exceed a five (5) day limit. R26 PERMANENT PAVEMENT REPAIR: After backfill and compaction operations have been completed, a temporary patch consisting of two inches (2") of SC -800 shall be placed immediately. A permanent patch of inches A.C. surfacing placed on a inch class base shall be placed no later than days after completion of temporary road repair. —SES /9ggrra�iyL Caw/�i� /`Z"5�o R27 PAVEMENT REPAIR: F.A.S.: Upon completion of backfill and compaction, a temporary patch consisting of two inches (2") of cold mix paving (SC -800) shall be placed immediately. A permanent patch of three inches (3") of A.C. surfacing shall be placed on six inches (6") concrete base as directed, but not later than fifteen (15) days after completion of temporary paving. Concrete base shall be of five -sack mix and shall conform to the City of La Quinta Road Improvement Standards and Specifications, Ordinance #1461. R28 FOG SEAL: A fog seal coat consisting of an application of asphaltic emulsion shall be applied over all patch areas as determined by the City Engineer. R29 SEAL ARMOR COAT: A seal coat consisting of an application binder and screenings shall be applied on all patch areas where such seal coats existed prior to issuance of this permit. Seal or armor coats shall be applied as specified in Section 37, Standard Specifications, State of California, Division of Highways, dated January 1973. Work of pavement repair to be accomplished by a licensed contractor engaged in the business of pavement repair. R30 STREET RESTRIPING: Where street striping is still visible on streets to be excavated, such striping shall be replaced upon completion of permanent repairs. R31 TREE RELOCATION OR REMOVAL: Tree relocation within the City of La Quinta road right of way shall be accomplished by a licensed, bonded and insured tree service, and handled safely without interference or hazard to the traveling public. It shall be the responsibility of the permittee to maintain the tree in a vigorous growing condition at its new location. Trees to be removed shall be removed in sections which can be handled safely without interference or hazard to highway traffic. The entire width of the tree stump shall be removed and disposed of so that no debris remains in view of the highway. The stump hole shall be backfilled and thoroughly compacted as specified in thefollowing paragraph. Where it becomes necessary to restrict traffic, the work shall be restricted to a maximum of 500 feet at any one time. Adequate signs, flagmen and/or barricades shall be provided to protect the traveling public at all times. Large holes resulting from tree removal shall be backfilled and compacted to not less than 90 percent or equivalent to the surrounding ground, whichever is the greater compaction as determined by the impact or field method. Compaction tests shall comply with Section 6.3.01 of the Standard Specifications, Division of Highways, State of California, dated January 1973. R32 TREE TRIMMING: a. Only the necessary trimming shall be accomplished to provide clearance of the facility for one calendar year. All broken or weak sections within the trimming shall be removed. b. Where it becomes necessary to restrict traffic, the work shall be restricted to a maximum of 500feet at anyone time. Adequate signs, flagmen, and/or barricades shall be provided to protect the traveling public at all times. c. If tree trunks are partially outside of the City of La Quinta road right of way, permittee shall make his own arrangements with adjoining property owners for consent to the trimming in addition to the authorization provided by this permit. d. All tree trimming on EVERGREEN TREES, PALM TREES, and other ORNAMENTAL TREES shall be accomplished to the satisfaction of the City Public Works Inspector. e. Abutting property owners shall be contacted, in all instances, prior to trimming or topping trees. f. Pruning shall, in all instances, be at the shoulder of the crotch to insure even, fast healing in all cuts of two inches (2") and above in size. Sealant shall be applied to all cut sections as directed by the City Public Works Inspector. ADDITIONAL CONDITIONS ENCROACHMENT'PERMI.T NO 372 R33 Survey monuments shall be protected in place or re-established,pursuant•to City standards and the State of California Land Surveyor's Act. R34 Contractor shall comply with the local noise ordinance and construction operations and maintenance of equipment:within one half mile of human occupancy shall be performed only during the'time periods as follows: October 1st to April 30:_ Monday -Friday 7:00a.m.-5:30p.m. Saturday 8:00a.m.-5:00p.m. May 1st.to September 30: Monday -Friday 6:00a.m.-7:00p.m. Saturday. 8:00a.m.-5:00p.m. Work shall be prohibited anytime on Sunday and Federal" holiday. R35 Traffic control shall be as per°Cal Trans Traffic Manual - Field adjustments in detouring shall be accomplished as . directed in order to adjust to. -actual field conditions. It shall be the contractor's;responsibility to adequately barricade and detour this.site. R36 All excavation at -or near`the,travel•way shall -be backfilled at the end'of the work day, for the protection of the traveling public. R37 This permit is only for work within public street right -of way. R38 Ingress .and egress for local properties shall be.maintained at all times R39 Prior to work -starting, Underground Service. Alert shall. be contacted. at 1-800-422-4133 and°an "inquiry number." -shall be.. provided to the City Public -Works Inspector. R40 Replacement pavement shall be existing asphalt thickness plus one inch, but not less than 3 inches.of. AC.pavement shall be placed:, Class 2 aggregate base shall be.as.per existing or 4" minimum (whichever -is greater). R41 If the work., is to be performed by forces other than that of' the utility company's than that contracting company will be required to apply for an additional encroachment permit and .pay the appropriate fee. CODE iIVLM c n u.T-Lu I DAZ / ' .EXT�IMn I LEAK TEST rf! i TOTAL P!R IN6T•D 4'r Isolation Area Affected ,�// Yes ❑ No U INSTALL NAIN WITH AT llA6T�dL1_� COVER BELOW F.rSi 97/7/3 A�PHLII T TOTAL PER RETIRED _ PSI o P(e$SU(B District.Affected Yea❑No O W�RETIREMENT PERMIT155VEDBY PERMIT NO, DATE MOVED DATE MOVED DATE OF ON JDD OFF JOB OPER. HAS I!�1�7. 3 Business District At Yes ❑ No COUNTY^`VE�S�/JE G7�yoF1ACJuiyT DATA _ Supply Line Affected Yes ❑ No DIfiTRICT _ j7ESE.tT REASON CREW FOREMAN OY Valve(s) Required Yes ❑ No TRACT. PLANNED BY COMPANY Reviewed By: 2i3 ATLA. //VD 93 YEAR C.P. RtiE_IY1-6BY, STAKED BTAKINO R[O'D. ❑INRALL[ COMPANY FACILITY: SO. CAkDQr, - P.L.S. ❑ DIVISION ' C.P. Reviewed By: Jt. CATMODICALY, Y onR.. aoA Oil OVEA D Tee ❑ No S.M,Y.S.' ..,. _, _�.... Ir•r. • .D ..,, •�•��...nrn••�rnn NO STAKES NEEDED ❑ W.O.