04-4033 (SFD)T-Odf 4 4Quhrw
P.O. Box 1504
28=_49,5-C.ALLE TAMPICO
A ,Q— _�� UINTA�,'
LCALIFORNIA 92253
BUILDING PERMIT
•.j. •L Y'YYV/:+iYV'ri fG'1�1'IGr YY. y •1
Proper y Address . . . . .
APN:
Application description
Property Zoning . . . . .
Application valuation . .
Owner
PUERTA AZUL PARTNERS
17700 SW UPPER BOONES FERRY RD
SUITE 100
PORTLAND OR 97224
BUILDING& SAFETY DEPARTMENT
(760).777-7012
FAX (760) 777-7011
INSPECTION REQUESTS (760) 777-7153
04-00004033 Date 5/11/04
80.890 VIA PUERTA AZUL
762-240-003-14 -300961-
DWELLING - SINGLE FAMILY DETACHED
MEDIUM DENSITY RES
85886
Contractor
DAVIS/REED CONSTRUCTION INC
169 SAXONY ROAD, STE #105
ENCINITAS CA 92024
(760) 634-2350-
WCC:
34-2350
WCC: STATE FUND
WC: WC298892003
06/12/04
CSLB: 813480
10/31/04
CCC: B-HIC
--------------------------
Structure Information -------------------------
.Construction Type . .
. . . TYPE V - NON RATED
Occupancy Type . . .
. . . DWELLG/LODGING/CONG <=10
Flo.od Zone . . . . .
. . . NON -AO FLOOD ZONE
Other struct info . .
. . . .CODE EDITION 2001 CBC
# BEDROOMS
2.00
FIRE SPRINKLERS NO
GARAGE SQ FTG
244.00
PATIO SQ FTG
1'63.00
NUMBER OF UNITS
1.00
FIRST FLOOR SQ FTG
1380.00
------------------------------------------------=---------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc
Permit Fee
576.50 Plan Check Fee
374.73
Issue Date . . . .
Valuation . . . .
85886
Qty Unit Charge
Per
Extension
BASE FEE
414.50
36.00 4.5000
THOU BLDG 50,001_100,000
162.00
--------------------------------
Permit . . . . .
----------------------------------------
MECHANICAL
----
Additional desc
Permit Fee . . . .
78.50 Plan Check Fee
19.63
Issue Date . . . .
Valuation
0
Qty Unit Charge
Per
Extension
P.O. BOX 1504
VOICE (760) 777-7012
78-495 CALLE TAMPICO FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT
Application Number: 04- :7033 I _ Date: S = /� •d!f
Applicant:
Applicant's Mailing Address:
/7<L-Z� s
Architect or En in is Addre s:
1 71
tic. NO.: C Z3' 222
t$UILUING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
Code, and my License is in f II force and effect. �i ,.%
P
�Lioense Class icense No. `
_Date
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for. the purpose of sale.).
U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to
the Contractors' State License Law.).
U I am exempt under Sec. , BA P.C. for this reason
Date Owner.
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
is iced; ry wo rs' compensa_ti�o�n w' eurance carrier and policy number are: /, 6
�rier 2f r i L KW(CP4 cy Number � C- e—� O S 9 Z, eo 3
_
I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with those provisions. /
uace Y'/Applicant %7s'"y r5 )«16-\r' 4--1
WAR NG: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under natty of`$�_ 7ury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name ti r -J4✓ �' T
�ender's Address
APPLI ANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the D rector of Building and Safety for a permit subject to the conditions and restrictions set forth on this a
1. Each person upon whose behalf this application is made, each application.
person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Quinta, its
2 officers, agents and employees for any act or omission related t rk-being.performed under or following issuance of this permit.
Any permit issued as a result of this application become and void if work is not corn nced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit t ncellation.
I certify that I have read this application and state that the ove information ' ecL I a mplyswith all city and county ordinances and state laws relating to building
construction, he by authorize representatives of this ounty to ente pon the as on party for inspection purposes.
/nate. Signature (Applicant or Agent):
Page
2
Application
Number
.04-00004033 Date
5/11/04
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
1.00
9.0000
EA
MECH FURNACE <=100K
9.00
1.00,
9.0000
EA
MECH B/C <=3HP/100K BTU
9.00
6.00
6.5000
EA
MECH VENT FAN
39.00
1.00
6.5000
EA
MECH EXHAUST HOOD
6.50
----------------------------------------------------------------------------
Permit .
. . . . .
ELEC-NEW
RESIDENTIAL
Additional
desc
Permit Fee
. . . .
68.18 Plan Check Fee
17.05
Issue Date
. . . .
Valuation . . . .
0
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
1380.00.
.0350
ELEC NEW RES - 1 OR 2 FAMILY
48.30
244.00
.0200
ELEC GARAGE OR NON-RESIDENTIAL
4.88
-
---------------
Permit .
-----------
. . . . .
-----
PLUMBING
----------------------------------
----------
Additional
desc
Permit Fee
. . . .
139.50
Plan Check Fee
34.88
Issue Date
. . . .
Valuation . . . .
0
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
12.00
6.0000
EA
PLB FIXTURE
72.00
1.00
15.0000
EA
PLB BUILDING SEWER
15.00
1.00
7.5000
EA
PLB WATER HEATER/VENT
7.50
1.00
3.0000
EA
PLB WATER INST/ALT/REP
3.00
1.00
9.0000
EA
PLB LAWN SPRINKLER SYSTEM
9.00
1.00
3.0000
EA
PLB GAS PIPE 1-4 OUTLETS
3.00
1.00
15.0000
EA
PLB GAS METER
15.00
---------------------------------------------------
Permit .
------------------------
. . . . . GRADING PERMIT
Additional
desc . .
Permit Fee
. . . .
15.00 Plan Check Fee
.00
Issue Date
. . . .
Valuation . . .
0
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
----------------------------------------------------------------------------
Special Notes
and Comments
SFD - LOT
14. PLAN 1AR. PERMIT
DOES NOT
Page 3
Application Number
. . . . .
04-00004033
Date
5/11/04
-------------------------------------------7--------------------------------
Special Notes and
Comments
INCLUDE BLOCK WALLS,
POOL, SPA
OR
DRIVEWAY APPROACH.
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
ART
IN PUBLIC PLACES -RES
.00
DIF
COMMUNITY CENTERS -RES
97.00
DIF
CIVIC CENTER - RES
366.00
ENERGY
REVIEW FEE
37.47
DIF
FIRE PROTECTION -RES
97..00
GRADING PLAN CHECK FEE
.00
DIF
LIBRARIES - RES
225.00
DIF
PARK MAINT FAC - RES
5.00
DIF
PARKS/REC - RES
502.00
STRONG
MOTION (SMI) - RES
8.58
DIF
STREET MAINT FAC -RES
15.00
DIF
TRANSPORTATION.- RES
1098.00
Fee summary
-----------------
Charged
----------
----------
Paid Credited
Due
Permit Fee Total
877.68
--------------------
.00 .00
877.68
Plan Check Total
446.29
.00 .00
446.29
Other Fee Total
2451.05
.00 .00
2451.05
Grand Total
3775.02
.00 .00
3775.02
INSULATION CERTIFICATE
• This is :o certify that insulation has been installed in conformance with.the current energy
regulal, i)n, California Administrative Code, Title 24, State of California, in the building located at
SOE-890 VIA =PUERTA AZUL LOT 14, PHASE 2, LA QUINTA CA
CEILIN QS:
TYPE:.13LOW MAUNFACTURER: Certainteed THICKNESS: R-38
WALL', i_
TYPE: BATTS MAUNFACTURER: Certainteed THICKNESS: R-19
GENERAL CONTRACTOR: DAVIS-REED CONSTRUCTION LICENSE #
PAR/! GON SCHMID BUILDING PRODUCTS AMASCO Company LICEIqSE#221517
BY:
ldTITLE: ACCOUNT REPRESENTIVE DATE:
0
0
rDEC -09-2004 10:33 PM
P. 11
CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING
11147
CF-a�2
��r v
Project Title�^
�yk leo ,1 1_`i U% Date %
Protect Add ass � Zl/I lr� ,�,.,�
6ulld r ,pe
Builder �5o_�ntact Tele hone
P Plen Number
HERS Rater —
T le hone Sample Group Number
L;Zez'
ifying Signature p to Sample HOu88 Number
irm:HERS Provider:
Street Address: 7i'.y OY City/State/Zip; Z4' '
Copies to: Builder, HERS Provider
HER 5 RATER COMPLIANCE STAT NT
The house was: ❑ Tested Approved as part of sample testing, but was not tested
As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form
COI with the diagnostic tested 'compliance requirements as checked on this form,
Distribution system is fully'ducted (i.e„ does not use building cavities aslenums or
VVVf ducts) P platform returns In lieu
rV1
here cloth backed, rubber adhesive duct tape Is installed, mastic and drawbands are used in combination
with cloth backed, rubber adhesive duct tape to seal leaks at duct connections.
❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT
Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage)
Duct Pressurization Test Results (CFM @ 25 Pa) Measured
values
•
n CFM
If fan flow is calculated as 400cfmT ntxLnumbeer of tonFlow ls niter
calculated value here
If fan flow is measured enter measured value here
Leakage Percentage (100 x Test Leakage/Fan Flow)
Check Box for Pass or Fail (P8ss=6% or less)
ass Fail
THERMOSTATIC EXPANSION VALVE 111I or Cotnmiss'
tin x rwcd equivalent
Yes [] No Thermostatic Expansion Valve (or Commission approvcd
equivalent) is Installed and Access Is provided for inspection
❑
Yes Is a passas
❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT
Pass Fail
1 0 Yes 0 No RCCA Manual D Design requirements have been met
(rater has verified that actual Installation matches values in
CF. 1R and design on plan.
; ..
2. ❑ Yes 17 No TXV is installed or Fan flow has been verified, if no TXV,
verified fan flow matches design from CF -1 R.
Measured Fan Flow =
Yes for both 1 and 2 is a Pass
� n
Pass Fail
C:
;
-72
f -D
/0
'y� �
0
QUINTA
`�C1TC
rF"'oF I' .w ING & S DEPARTMENT
7 12
MPE�CaTIO R "QUEST LINE
CI-ry OF LA 77-7 53
Owner
i
Contractor. DA RFFTI ((1NCTRUfM(j
Permit Number04-4033
POST ON JOS IN CONSPICUOUS PLACE
INSPECTOR MUST SIGN ALL APPLICABLE SPACES
JOB ADDRESS —S®-890 VIA P17FI13TA
SF'D – LOT 14, PLAN IAR. PERMIT DOES NOT
INCLUDE POOL, SPA, BLOCK WALLS, OR
DRIVEWAY APPROACH
TYPE OF INSPECTION DATE P�s::
TEMPORARY POWER
U/G PLUMBING /WASTE
U/G ELECTRICAL / GROUNDING
FOOTINGS / STEEL
CONCRETE SLAB
DO NOT POUR CONCRETE UNTIL ABOVE SIGNED
ROOF NAIL/ PRE -ROOF
OKAY TO WRAP
FRAMING COMBINATION
ROUGH ELECTRIC
ROUGH PLUMBING
ROUGH MECHANICAL
INSULATION '
COVER NO WORK UNTIL ABOVE SIGNED
I EXTERIOR LATH
GAS TEST
SEPTIC ABANDONMENT
SEWER CONNECTION
SEPTIC / GREASE INTERCEPTOR
MASONRY INSPECTIONS
FOOTINGS /STEEL
i BOND BEAM
POOL / SPA / WATER FEATURE INSPECTIONS
PRE-GUNITE / SETBACKS
U/G PLUMBING
U/G GAS
U/G ELECTRICAL
PRE -PLASTER (ALARMS/ BARRIERS)
FINAL INSPECTIONS
TEMP. USE OF PERMANENT POWER
ABOVE APPROVALS DO NOT INCLUDE RIGHT TO
TURN ON UTILITIES OR OCCUPY BUILDING
PLUMBING
MECHANICAL
•
PUBLIC WORKS DEPARTMENT
COMMUNITY DEVELOPMENT DE
FINAL / JOB COMPLETED
ABOVE APPROVALS DO NOT INCLUDE RIGHT TO
TURN ON UTILITIES OR OCCUPY BUILDING
ESI/FME,.Inc.
STRUCTURAL ENGINEERS & CONSULTANTS
1800 E. 16TH ST. • SANTA ANA, CA 92701 • (714)835-2800 • FAX(714)835-2819
STRUCTURALOBSERVATION REPORT FORM
:PROJECT NAME
iPUERTA AZUL
O WNER/DEVEL-OPER
:PACIFIC LAND
PAGE 1 of
MANAGEME
ESI/FME JOB NO.
STRUCT. OBSERVER
TYPE
PHASE
PLAN/UNIT #
ELEV. r
ILOT#
402-3113
KEN SADLER
jBLDG.
NA
`°
I
PLAIJ (
-A 12 I
I
ESI/FME FILE NO.
PROJECT LOCATION
FIELD REP.
REPORT NO:
DATE OF OBS
3113-
LA QUINTA CA.
MARK ALEXANDER
OBSERVED STRUCTURAL ELEMENTS j
FOUNDATION U SHEAR WALL ASSEMBLY QX WALL FRAMING ❑X SHEAR TRANSFER O DRAG TIES/STRUTS,
HARDWARE CONNECTIONS CHORDS & THEIR
[j FLOOR FRAMING O ROOF FRAMING E] STEEL FRAME/COL.CONNECTIONS
----- ---
f
# I LOCATION REMARKS
Ol" I ii�✓]lt_cr- De.l.,•t4 a.uc/oa: �.t—P¢rS e� P3t.�rS �.t3c:r� S7✓to,,c4-G✓Att_S Pte"+—' �:.�v�f
Q I pp__f.?cv2__� <t-vi_ar-rr i* -rZZ !•F, . ix
� � j�,s✓1Z �F G ,4i!/�f -, — ac r �
i .
i —
SKETCHES AND/OR ADDITIONAL COMMENTS:
I PREPARED BY:
;ESI/FME, Inc. ���
. � Y
X '0
CHECK IF COMMENTS / SKETCHES CONTINUED ON ATTACHED SHEET
-
4�r DISCLAIMER ESUFME, INC. DID NOT INSPECT THE SUBJECT UNIT. THIS WAS A WALK-THROUGH
015316r" FRAMING REVIEW TO DETERMINE IF THE CONSTRUCTION SUBSTANTIALLY COMPLIES WITH THE I
9/�/� :10m CONSTRUCTION DOCUMENTS AND STRUCTURAL DESIGN INTENT. OUR REVIEW COVERED MAJOR j
�'rn FRAMING ELEMENTS AS REFLECTED IN OUR CALCULATIONS. THIS REVIEW WAS BASED ON VISUAL
OBSERVATIONS AND THERE IS NO CLAIM, EITHER STATED OR IMPLIED, THAT ALL CONDITIONS WERE
�Q OBSERVED. WE DO NOT CERTIFY OR GUARANTEE THE CONSTRUCTION WORK IN ANY WAY. OUR
_ VISIT DOES NOT RELIEVE THE DEVELOPERS, FRAMERS, CITY INSPECTORS AND DEPUTY INSPECTORS
JF _ -" IF APPLICABLE AS TO THEIR OBLIGATIONS TO FOLLOW THE PLANS AND ALL APPLICABLE CODES.—_j
,- Certificate of Occupancy
- _ -4ot Qum&
G� OF'Tk�Building y p & Safety Department
This Certificate is issued pursuant to the requirements of Section 109 of the California Building
Code, certifying that, at the time of issuance, this structure was in compliance with the
provisions of the Building . Code and the various ordinances of the City regulating building
construction and/or use.
BUILDING ADDRESS: 80-890 VIA PUERTA AZUL
Use classification: SINGLE FAMILY DWELLING Building Permit No.: 04-4033
Occupancy Group: R3 Type of Construction: VN Land Use Zone: RM
PUERTA AZUL PARTNERS LLC. Address: 17700 SW UPPER BOONES FERRY
City, ST, ZIP: GARY HARTMAN
Date: FEBRUARY 17, 2005
Building Official
POST IN A CONSPICUOUS PLACE