Loading...
11-1296 (RER)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 .Application Number x;.11 -00001296TH" ^-' _rtyTAddress: 51735; VIA*ROBLADA Woj�e APN: 772 -270 -010 -29 -311231 - Application description: REMODEL - RESIDENTIAL Property Zoning: LOW 'DENSITY RESIDENTIAL Application valuation: 1 2800 Applicant: Architect or. Engineer: -.BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner:. JAMES BRANDT 51735 VIA ROBLADA LA QUINTA, CA 92 ..Contractor: J E CONSTRUCTION 1560 ORQUESTA CT COLTON, 'CA 92324 (909)503-6926 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153' Date: i2/02/11 LQPERMIT LIC. NO.:.814637 r�r- --------------------------------------- --- LICENSED CONTRACTOR'S DECLARATION - WORKER'S COMPENSATION DECLARATION I hereby affirm "underpenalty 'of perjury that I am licensed under provisions.of Chapter 9 (commencing with 1 hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as.provided. License Class: B - Lice e NIP.: 814637 for by Section 3700 of the -Labor Code, for the performance of the.work for which this permit is issued. "Date - OZ, contractor: I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor, • . y_ Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILD DECLARATION insurance carrier and policy number are: �- I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the '- Carrier STATE FUND.' Policy Number 1709249 following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed, statement that he or she is licensed pursuant to the provisions of the Contractor's State and, agree that, if I should b ome subject to'the workers' compensation provisions of Section - License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or - 3700 of the Labor C s II forth h comply it provisions: that he or she is exempt therefrom and the basis for.the alleged exemption. Any violation of Section 7031.5 by Ose �.,.r•-�- . j Applicant:""' any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:. Date:) � _ (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, ander the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING:' FAILURE TO SECURE ORKERS' COMPENSATION VERAGE Is UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVI .FINES UP TO ONE HUNDRED THOUSAND • and who does the work himself or herself through his or herown employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or.she did not build or , improve for the purpose of sale.). - APPLICANT ACKNOWLEDGEMENT (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. . property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.).. - _ whose benefitwork is performed under or pursuant to any permit issued as a result of this application, _ (_ ). I am exempt under Sec. - , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City ' ' - of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. - Date: Owner: '2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, "or cessation of work for 180 days will subject - CONSTRUCTION LENDING AGENCY permit to cancellation. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have readthis application and state that the above. information is correct. I agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). city and county ordinances and state laws relating to buildin onstruction, and hereby authoriz epres tatives - of.this county to enter upon the above-mentioned prope for nspection oses.- , Lender's Name: -r ate:+�--(A ^ ""`. '•""'. '� r -- Date: !i � (Applicant or Agent): ` - Lender's Address: - gnature '—-�• -� - LQPERMIT Application Number 11-00001296 -Permit BUILDING PERMIT 'Additional.. desc .. Permit.Fee54.00 Plan.Check Fee 35:10 ; Issue Date Valuation 2800 •,.. ,. .. - .. 5/30/12 . Exp. iration Date Qty Unit "Charge ` Per " Extension -_ BASE'YEE .45..00 1.00 9.0000•THOU' BLDG 2,001-,25.,000 9.00 -----Special Notes. and°Comments. ADD,2 FIXED WINDOWS.AT NORTH SIDE.OF .. SFD; PER STAMPED ENGINEERING LETTER. 2010 CODES,.. Other Fees' . ... BLDG STDS ADMIN.(SB1473)`. 1.00 ENERGY REVIEW FEE 3.51. STRONG -MOTION (SMI) -. RES .50 . Fee summary Charged. Paid Credited, Due : -!------------ Permit Fee Total 54.00 .00 .00 54.00 Plan Check Total'' 35.10 ...00 .00 35.10 "Other Fee Total' 5.01 .00 .00 5.01 Grand Total 94'.11° .00':• .00 94..11 . LQPERMIT' Bin # Citk of. LaQuint . - r, Building 8t Safety..Wslon . P.O. Box 1504, 78-495 Calle.Tamplco . La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: .S / Owner's Name: A. P. Number: Address: /" Legal Description: City, ST, Zip: Contractor. U h Telephone Address: /s-o'no Project Description: City, ST, Zip: O ( i-7 Telephone: „•'•�-�. - y;• �, S"0 3 -� <:::::,:::;: ;.ate>+:4rK . State Lic. j City Lic. � � Arch., Engr.,' Designer: Address: City, ST, Zip: Telephone: Construction Type: Occupancy: Project type (circle one): New Add'n . Alter . Repair Demo • ''C'n-jM:y`�i:±:i'=:f:::vwi-+-Y'fj.7 i State Lic. #:N Name of Contact Person: Sq. Ft.:#Stories. # Units: Telephone # of Contact Person: Estimated Value of Project:. p2 APPLICANT: DO NOT WRITE BELOW THIS UNE 1t Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted- �Z ' Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit Truss'Calcs. Called Contact Person Plan Check Balance 15de 24 Coles. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 20° Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Pians resubmitted Grading IN HOUSE:- 3W Review, ready for correctionstissue Developer Impact Fee ' Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees CHARLES D. GARLAND ARCHITECT r Architecture, Interiors, Space and Land Planning, and Structural Design, ` Principle: Charles D. Garland, Architect Associate: Efrain Cardenas, Engineer in Training 1 December 2011 ' The City of La Quinta Department of -Building and Safety 78.495 Calle Tampico - La Quinta; CA 92253 Project: Single Family Residence Alterations for: Mr. Jim Brandt 51-735 Via Roblada , La Cantera La Quinta, California Regarding: Structural Direction and Certification To Whom It May Concern, .1 am a licensed architect in the state of California and I have been asked to visit the noted project site in order to consult with and direct, the Designer, Edwin. Vela, on the structural implications of Mr. Brandt's proposed alterations. The alterations consist of adding two (2) relatively small fixed windows on the north side of his home which is essentially a blank wall currently. I have reviewed the existing construction documents of record on file at the City with Mr. Vela and determined that 1) the windows are being added in a portion of the north wall that is not: by record, a part of a shear wall and 2) that the existing, 26'-0" (+) shear wall to the west of the intended window addition will not intrude into any part of the said shear wall. Further, I have directed Mr. Vela to add drag detailing along the headers thus tying them into and dragging the applied. lateral loading from the non -shear to the existing shear wall system.. Finally, I have reviewed the drawing and detailing prepared by Mr. Vela and find them satisfactory to be used for construction, subject to the City's review and approval, and as I have directed their structural content to include. If you have any further -questions re I ct please do not hesitate in contacting me. 15 0- 04A Si cerely, $ U No. C11991 .O EXP. DATE Charles D. Garland Architect F 74-991 Joni Drive, Suite 9 Palm Desert, CA 92260 o Phone: (760) 340-35218/Facsimile (760) 340-3728S i Prescriptive Certificate of Compliance: Residential CF -IR -ALT Residential Alterations age 1 of Project Name:_ t� ; ,/ Climate Zone N 10 of Stories General Information Site Address: Enforcement Agency: Date: Building Type O Single Family O Multi Family Circle the Front Orientation: N, E. S, W, or degrees Conditioned Floor Area (CFA): Project Type: O Alterations O Envelope O Fenestration O Roof O HVAC Reptace.Tnent or Change Out O Duct Replacement O Water Heater NO .f f j y &W or Addidonns T : Thisform Lr not to be usedfor IVewl Camsttwdtd Bull' insulation Values For Opaque Surfaces (for Furring use the Mass and Furring Strips Construction table below) Assembly Alteration O Opening of framed cavity alone - Alterations that involve the opening of the framed cavity of a wall, ceiling, or floor must install the mandatory minimum insulation value per §l S0 for the altered assembly. Fill in Columns A -C and enter mandatory insrtlation.value in Column H. O Replacement of entire assembly - Replacement of an entire wall, ceiling, or floor assembly requires the installation of Component Package- D insulation values in Table 15 1-C. Fill in Columns A - J. I Upaque SurTBce Details Fortke furred portioned of Mass Walls see Furrine Strips Constrrretion Table below. 1 f I Framing T wlmss, Framed Continuous I JAd Proposed ITei 1 Assembly Name Material . Spacing. U- JA4 Table Cavity Insulation Assembly As9anbl iD or Type and Size, or Otl>er' factor' I Numbed I R -value° R -Value' Cell Valuer U-&Ctnr Note: For furnrd a senrblies, accomting for Conrimaur Insulation R-vatue, see Page JAI -3 and Equation 4-1. For ealadamW furred Malls use dx Aim and Farring Cam antcrion table below. I. For T391D indicate the tdentication name that matches the building plans. 2. Indicate the Assembly Name or type: RoofiCeiling, Walls, Floors. Slabs, Crawl Space, Doors and etc... Indicate the Frame type and Size: For Wood Aletal, Metal Buildings, Mass, enter 2x4, 2x6, or etc... see JA for other possible frame type assemblies. 3. fitter the thidme rs for mass in inches or Spacing between framing members enter: 16 "or 24 "OC. or Other for all other assembly description such as Concrete Sandwich Panel. Spanrdrel Panel. Logs, Straw Bale Panel and etc.... 4. Based on the Climate Zone: enter the Standard U factor from Table 15 I -B. C or D for each dif jerent assembly None or. type. S. Enter the Table number that closely resembles the proposed assembly. 6. Enter the R -value that is being installed in the wall cavity or between the framing; otherwise. enter "0 " 7. Enter the Continuous Insulation R -value for the proposed assembly; otherwise, enter 8. Enter the row and column of the U factor value based on Column F Table Number and enter the Assembly U factor in Column J 9. Ilse Proposed Assembly U factor, Column J, must be equal to or less than the Standard U factor in Column E to comply - Furring Strips Construction Table for Mass Walls Ont A B 1 C 1 D E F G I H Ii J K L M Proposed Properties of Masonry and Concrete Added Interior or Exterior Insulation Walls From Reference in Furring Space from Reference Joint Appendix Table 4.3.5,4-3.6.4.3.7 Joint Appendix Table 4.3.13 w Assembly q 0 ° c F [= o �" 2 a" Final Mass Name or JA4 Table �' v e 4 a li E $ E � S t> v a; Assembl}• 47 Comment = Thickness'T Number' < > c k L o LL ad < > U -factor Registration Number: Registration Date. Time: 2008 Residential Compliance Forms HERS Provider: A ugust 200 Prescriptive. Certificate of Compliance: Residential CF -IR -ALT Residential Alterations Pa e 2 of 5 Project Name: Climate Zone q H of torics � : Mass and Furring Strips Construction(footnotes) 1. Indicate the type of assembly to include: Hollow Unit .Nasonry Walls. Solid Unit Uasonry. Solid Concrete Walls. Etc. Additional assemblies can e found Reference Joint Appendix J44. . This is the U -Factor based on the thickness of the assembly in inches. 3. The R -value of the insulation to be added on the interior or exterior of the assembly. 4. The Calculated R-1 alue is the R -value of the furred out section of the assembly. 6. The Fina! Assembly is calculated using Equation 4-2 or Equation 4-4ojthe Reference Joint Appendix JA 4. The equation is the inverse of Colum radded to Column L Column K is the inverse from column J. 7. insert the calculated U factor value on to the Opaque Surface Details in Column J FENESTRATION PROPOSED AREAS ❑ Replacing window alone — Replacement windows shall meet the U -Factor and SHGC Value requirements of Component Package D in Table 151-C. The Tota! Fenestration and West facing Area requirements are not applicable. ❑ Adding 50fe or less of window area —Newly installed windows shall meet the U -Factor and SHGC IWue requirements of Component Package D in Table 151-C. ❑ Adding more than 50ft' of window area — .Newly installed windows shall meet the U -Factor and SHGC Value and the Fenestration Area requirements of Component Package D in Table 151-C Complete the Altered Fenestration Allowed Area Table on Page 1 of the CF -/R -ALT Orientation Fenestration Type and Frame Window Glass Door or Skylight)South, (North. East PropsedAreal I Maximum I Maximum NFRC or Default West ft U-factorz 3 SHGCZ. i' 4 Vatues• ; ^i m V �q ✓ , Z ` . Total Fenestration Area qS .20 West Fenestration Area 1. Fenestration area is the area of total glazed product (i.e. glass plus frame). Exception: When a door is less than 50.16 glass: the fenestration area may be the glass area plus a -2 inch frame " around the glass. 1. Enter value from Component Package D Requirements in Table 151-C. 3. Actualfenestration products installed and as indicated in CF -6R -ENV' Form shall be equivalent to or have a lower [U -factor antdor a lower SHGC value than that specified on the CF -IR ALT Form. 4. Submit a completed WS -3R Form if a reduced SHGC is calculated with exterior shading. 5. ffappikable at this stage enter "NFRC-for NFRC Certified windows or are CEC "Default - values found inlable 116-A or B. ALTERED FENESTRATION ALLOWED AREAS (Co del .harethan 50ft' o jenesfradon is add4 A B C D E F G Allowed Existing Fenestration Total Area CFA of Entire % of Fenestration Area Fenestration Allowed Proposed Area Dwelling CFA Area Removed Area Added A x B) (E -D) + C Total Fenestration Area .20 West Fenestration Area (Required In .05 CZ's 2,4&7-15) 1. West Fenestration Area includes west -sloping skylights and any skylights with a pitch less than 1:12. 1. West facing glaring area removed cannot be ..counted- twice.. In order to distribute the west g/a=ing area removed to the other orientations input the west glazing area removed in the Total Fenestration Area raw, column D. 3. Include the Proposed Area of the West facing fenestration in both Area columns below. 4. To meet compliance. the Proposed Area must be less than orequal to the Total Allowed Area or BOTH the Total and West Fenestration Ares Registration A -umber: _ Registration Date Time: 2008 Residential Compliance Forms HERS Provider: August 2 Prescriptive Certificate of.0 Residential Alterations Project. Name: ,.,4ts /? ential. Climate Zone# 'F -IR -ALT e_ 'age 5 of 5). # of Stories HERS VERIFICATION SUMMARY The enforcement agency should pay special attention to the HERS Measures specified in this checklist below, A completed and signed CF -AR Form for all the measures specified shall be submitted to the building inspector, before final inspection. Duct Sealing & Testing HERS verification is required for this measure. O YES O NO YES: In Climate Zones 2 and 9-16. if more than 40 linear feet of new or replacement ducts are installed in unconditioned space, the ducts are to be sealed per §152(b)IDii and.the newly installed ducts are to be insulated per §151(f)10. O EXCEPTION: Existing duct systems that are extended, which are constructed, insulated or sealed with asbestos. O YES O NO YES: In Climate Zones 2 and 9-16. if the existing space -conditioning system (HVAC equipment and ducting) is.replaced, the ducts are to be sealed per § 152(b) I Di. ❑ YES O NO YES: In Climate Zones 2 and 9-16. if the existing HVAC equipment is replaced (including the replacement of the air handler, outdoor condensing unit of a split system. cooling or heating coil. or the furnace heat exchanger) the ducts are to be sealed per §152(b)IE. O EXCEPTION: Duct systems that are documented to have been previously sealed confirmed through HERS verification in accordance with procedures in the Reference Residential Appendix RA3. . O EXCEPTION: Duct systems with less than 40 linear feet in unconditioned space - 13 EXCEPTION: Existing ducts stems constructed, insulated or sealed with asbestos. Refrigerant Charge - Split System HERS verification is required for this measure. 0 YES ONO YES: In Climate Zones 2 and 8-15, when the existing HVAC equipment is replaced (including the teplacement of the air handler. outdoor condensing unit of a split system A/C or heat pump, cooling or heating coil. or the furnace heat exchanger) a refrigerant charge measurement shall be verified per 152(b)IF. Central Fan Integrated (CFI) Ventilation System and Fan Watt Draw The ventilation requirements of § 15 o do not apply to existing residential homes. Ducted Split Systems - Air Conditioners and Heat Pumps: Airflow HERS verification is required for this measure. O YES O NO YES: In Climate Zones 10 through 15, when the existing space -conditioning system (HVAC equipment and ducting) is replacedL the airflow and fan watt draw shall be verified per § 152 b lCi to meet the requirements of §151(f)7B. Documentation Author's Declaration Statement • l certify that this Certificate of Compliance documentation is accurate and complete. Name: .r✓o e, Signature: Company: ate: Address:/ If Applicable O CEA or O CEPE 0 ve, A � (Certification #): r City/State/Zip: I Phone - © Responsible Building Designer's Declaration Statement • 1 am eligible under Division, 3 of the California Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 1 certify that the energy features and performance specifications for the building design identified on this Certificate of Compliance conform to the requirements of Title 24. Parts I and 6 of the California Code of Regulations. • 'The building design features identified on this Certificate of Compliance are consistent with the information provided to document this building design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit- application. . Name: Signature:. 4 Company: Date:. Address:License: ; City/State/Zip: Phone: For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300. Registration Number: _ _ Registration Date -Time: HERS Provider: 2008 Residential Compliance Forms August 2' eft � � Bei � a4 � �� �y. f f - ..- • I ' BUILDING ENERGY,ANALYSIS REPORT PROJECT: Brandt Residence 51-735 Via Roblada , La Quinta, CA 92253 Project, Designer: Edwin A. Vela ; 77917 Wildcat Dr. Bermuda Dunes,YCA,92203 760-587-5217'. } 'Report Prepared by: • Gina Rose -Starkey u EQS, Inc: t `, a� - ' 42335 Washington St. #F-330 'j • r ' ,'Palm Desert, CA 92211 760-218-3350. ' C 01Z ITY UILDING & C�UINTA Job Number: OL VED, Fo ,PpFj DEpT R CON, TRUCTI Date: «(. a f •. .11/17/2011 ,• _ The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and,is authorized by the California Energy Commission for use with both the Residential and. Nohresideritial 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLCM www.'energysoft.com. Ener Pro 5.1 by EnergySoft User Number. • 5862 RunCode: 2011-11-17710:27:52 ID: EnerijyPro 5.1 by EnergySoft : ' Job Number. ID: User Number: 5862 4 � � fit P y � / Y' • TABLE OF CONTENTS- ONTENTS Cover Cover Page 1 ,. - •Table of Contents _ + 2 ' Form CF -1 R Certificate of Compliance • ;�N s 3 . a ,; ._ •• ,�1 .. ': � r r, ' .•, � '. ,. � :may r. Y rw � ' •. - - e .r , �w ,, _ •� .'•, . r ,� Ir '' {' `y Pr .• r I `•-moi• r• 1 EnerijyPro 5.1 by EnergySoft : ' Job Number. ID: User Number: 5862 4 � � fit P y � / Y' • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Brandt Residence Building Type 0 Single Family ❑ Addition Alone 0 Multi Family ❑ Existing+ Addition/Alteration Date 11/17/2011 Project Address 51-735 Via Roblada La Quinta California Energy timate Zone CA Climate Zone 15 Total Cond. Floor Area 2,780 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes 0 No HERS Measures'-- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. 6 Yes ❑ No Special Features —'If Yes, see Part 2 of 5 of this form for details. -INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status Wall Wood Framed R-21 2276 Existing Door Opaque Door None 27 Existing Slab Unheated Slab-on-Grade None 2,780. Perim = 286', ' Existing Roof Wood Framed Attic R-38 2,780 Existing FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Left (N) 16.0 0.710 0.60 none none Bug Screen Existing Left (N) 15.0 0.330 0.26 none none Bug Screen New Rear (E) 74.3 0.710 0.60 none none Bug Screen Existing Right (S) 147.8 0.710 0.60 none none Bug Screen Existing Front (149 20.0 0.710 0.60 none none Bug Screen Existing r HVAC SYSTEMS Heating Min. Eff Cooling, Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing 'HVAC DISTRIBUTION ' Duct Location Heating Cooling Duct Location R-Value Status Existing Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Oty. Type Gallons Min. Eff Distribution Status Ene Pro 5.1 by EnergySoft User Number. 5862 Runcode: 2011-11-17T10:27:5 ID: Page 3 of 8 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Brandt Residence Building Type ® Single Family ❑ Addition Alone ❑ Mufti Family ❑Existing+ AdditioNAfteration Date 11/17/2011 SPECIAL FEATURES INSPECTION CHECKLIST ' The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special "ustificafion and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 1,666.0 ft' Exposed Slab Floor, 3.500' thick at Existing Home HIGH MASS Design - Verify Thermal Mass. 1,114.0 fF Covered Slab Floor, 3.500' thick at Existing Home HERS REQUIRED .VERIFICATION y Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listedbelow for final to be given. P b EnenjyPro 5.1 by EnergySoft User Number. 5862 RunCode. 2011-11-17T10:27.5 ID: Page 4 of 8 i PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Brandt Residence ❑ Multi Family ❑ Existing+ Addition/Afteration 11111712011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 Space Heating 3.84 1.73 2.11 Space Cooling 107.76 101.01 6.75 Fans 23.39 21.85 1.54 ° Domestic Hot Water 0.00 .0.00 0.00 Pumps 0.00 0.00 0.00 Totals, 134.99 124.59 10.40 ^ Percent Better Than Standard: 7.7% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (►M 270 deg Ext. Walls/Roof Wall Area Area " Number of Dwelling Units: 1.00 (W) 495 20 Fuel Available at Site: Natural Gas (N) 174, 31 Raised Floor Area: 0 (E7 513 i 74 Slab on Grade Area: 2,780 (S) 794 148 Average Ceiling Height: 9.0 Roof 2,780 0 Fenestration Average U -Factor: 0.69 TOTAL: _ 273 Average SHGC: 0.58 Fenestration/CFA Ratio: 9.8% REMARKS, t STATEMENT OF COMPLIANCE - This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations.. - The documentation author hereby certifies that the documentation is accurate and complete: Documentation Author Company EQS, Inc. ;. 11/17/2011 Address 42335 Washington St. #F-330 Name Gina Rose -Starkey City/State/Zip Palm Desert, CA 92211 Phone 760-218-3350 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and any other calculations submitted with this Permit application, avid recognizes'that compliance using duct design, _with duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Edwin A. Vela Address 77917 Wildcat Dr. Name Edwin A. Vela f City/State/Zip Bermuda Dunes, .CA 92203 Phone 760-587-5217 Siked License # ' Date En;;Wm 5.1 by Ene Soft User Number. 5862 RunCode: 2011-11-1TT'f0:27.5 ID: Pae.5 of 8 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Brandt Residence Building Type ® Single Family ❑ Addition Alone O Multi Family ❑ Existing+ Addition/Afteration Date 1/17/2011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 743 0.069 R-21 0 90 Existing 4.3.1-A6 Existing Home Wall 439 0.069 R-21 90 90 Existing 4.3.1-A6 Existing Home Wall 646 0.069 R-21 180 90 Existing 4.3.1-A6 Existin Home Wall 448 0.069 R-21 270 90 Existing 4.3.1 A6 Existing Home Door 27 0.500 None 270 90 Existing 4.5.1-A4 Existing Home Slab 1,666 0.730 None 0 180 Existin 4.4.7 Al Existing Home Roof 2,780 0.025 R-38 0 0 Existin 4.2.1-A21 Existing Home Slab 1,114 0.730 None 0 180 Existing 4.4.7 Al Existing Home FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 8.0 0.710 Default 0.60 Default 0 Existing Double Metal Tinted Existing Home 2 Window 7.5 0.330 NFRC 0.26 NFRC 0 New Minimum Existing Home 3 Window 7.5 0.330 NFRC 0.26 NFRC 0 New Minimum Existing Home 4 Window 8.0 0.710 Default 0.60 Default 0 Existing Double Metal Tinted Existing Home 5 Window 1 16.5 0.710 Default 0.60 Default 90 Existing Double Metal Tinted Existing Home 6 Window 16.5 0.710 Default 0.60 Default 90 Existing Double Metal Tinted Existing Home 7 Window 8.0 0.710 Default 0.60 Default 90 Existing Double Metal Tinted Existing Home 8 Window 33.3 0.710 Default 0.60 Default 90 Existing Double Metal Tinted Existing Home 9 Window 12.5 0.710 Default 0.60 Default 180 Existing Double Metal Tinted Existing Home 10 Window 8.0 0.710 Default 0.60 Default 180 Existing Double Metal Tinted Existing Home 11 Window 25.0 0.710 Default 0.60 Default 180 Existing Double Metal Tinted Existing Home 12 Window 15.0 0.710 Default 0.60 Default 180 Existing Double Metal Tinted Existing Home 13 Window 4.0 0.710 Default 0.60 Default 180 Existing Double Metal Tinted Existing Home 14 Window 25.0 0.710 Default 0.60 Default 180 Existing Double Metal Tinted Existing Home 15 Window 25.0 0.710 Default 0.60 Default 180 Existing Double Metal Tinted Existing Home 16 Window 33.3 0.710 Default 0.60 Default 180 Existing Double Metal Tinted Existing Home (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13= Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hgt Wd Overhanq Left Fin Len Hqt I LExt REA Dist Len Hgt Ri ht Fn Dist Len Hgt 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug, Screen 0.76 16 JBug Screen 0.761 1 EnergyPro 5.1 by EnergySoft User Number. 5862 RunCode: 2011-11-17T10:27:5 ID: Pae 6 of 8 4,• CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Brandt Residence Building Type 0 Single Family 0 Addition Alone , 0 Multi Family 0 Existing+ Addition/Alteration Date 1/17/2011 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tift Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor sHGC2 Azm Status Glazing Type Location/Comments 17 Window 10.0 0.710 Default 0.60 Default 270 Existing Double Metal Tinted ' Existing Home 18 Window 10.0 0.710 Default 0.60 Default 270 Existing Double Metal Tinted Existing Home (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC T e: 116-8 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove ang Left Fn Right Fin ID Exterior Shade Type SHGC H t Wd Len Hgt LExt RExt Dist Len Hqt Dist Len Hgt 17 Bug Screen 0.76 18 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number. 5862 RunCode. 2011-11-17T10:27.5 /D. Page 7 of 8 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project'Name Brandt "'Residence Building Type 0 Single Family ❑ Addition Alone ❑ Multifamily ❑ E)asting+ Addition/Afteration Date 11117/201 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New EAstina Altered Removed Volume Year Built Existing Existing Home 2780 25,020 2001 Totals 01 Z7801 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Existing 2 Central Fumace 80•/ AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Existing Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing 13 13 WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status CEC Standard MULTI -FAMILY WATER HEATING DETAILS I HYDRONIC HEATING SYSTEM PIPING Control E(ft) E m w a. Hot Water Piping Length o v M ¢ — System Name Pipe Length Pipe Diameter Insul. Thick. HP Plenum Outside Buried ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Enqn7yPro 5.1 by EnemySoft , User Number. 5862 RunCode: 2011-11-1 M0:27.5 Q Pace 8 of 8 rI i 1 111 .w. fl k L I z CALFORNIA ADMINISTRATIVE CODE O ... (E) SHEAR TRANSFER/TRUSS BLK'G DETAIL LL v PP,OJECT _DATA, SKEET INDEX OWNER: MR. JIM BRANDY Lf Q A.1_ SITE/PLOT PLAN 77 :SITE: .�r .;,.... 51-735 VIA ROBLADA WINDOW DETAILS �= -- LA QUINTA, CA 92253 ZONE: RESIDENTIAL Q LOT SIZE: 7,143 SQ. FT. U EXISTING RESIDENCE: 2,780 SQ. FT. Q TOTAL NEW CONSTRUCTION: 13.8 SQ. FT. EFT SCOPE OF WORK. ADDING TWO 30 X 33 -FIXED WINDOWS AT L . ► _ SHEET TITLE: I REAR CORNER OF HOME. PLOT PLAN SITE PLAN S I�U�LDYNGSPECIF"ICATIONS DETAILSUTILITY COMPANITh D R A W N E.A.V. C H E C K E THIS PROJECT SHALL COMPLY .WITH THE FOLLOWING: D EDWIN A. ` VELA - CABLE T.V. TIME .WARNER CABLE DAT E 888.476.4990 2010 CALIFORNIA BUILDING CODE DEC. 1ST 2011 2010 CALIFORNIA RESIDENTIAL CODE -r- S C A t_ E g NATURAL GAS SOUTHERN CALIFORNIA GAS COMPANY CITY OF LA T �. » » SE -,L j __2LBUILDING & SAFE`S C, a . 800.427.2200 2010 CALIFORNIA MECHANICAL CODE , .�., J o e N .AME A + � BRANDY RESIDENCE ELECTRICITY SOUTHERN CALIFORNIA EDISON 2010 CALIFORNIA PLUMBING CODE FOR CONSTRUCT SCALE: _ 1/8"=V-0" 760.369.5403 _. SHEET , 2010 CALIFORNIA ELECTRICAL CODE oar WATER COACHELLA VALLEY WATER DISTRICT l 760.398.2651 2010 CALIFORNIA ENERGY CODE D Ac - O 2010 CALIFORNIA FIRE CODE R 2010 CALIFORNIA GREEN BUILDING CODE — --f --fig-- � �e �...i ri THESE DRAWINGS ARE COPYRIGHTED z CALFORNIA ADMINISTRATIVE CODE O ... SITE INDICATED IN THE DRAVBNG(S) ONLY. THIS DESIGN AND DRAWINGS& ARE SUBMITTED AS RESTRICTIVE AND CON TIAL DISCLOSURE THAT MAY NOT BE USED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE DESIGhffR. DESIGNER SHALL NOT BE RESPONSIBLE FOR W N PERMITS. REVISIONS BY ■. ■ C3 ■F� zej W O^0 IA 0 m U � C 3 a zbm o b ® W W cs 661 0 m (E) SHEAR TRANSFER/TRUSS BLK'G DETAIL LL v PP,OJECT _DATA, SKEET INDEX OWNER: MR. JIM BRANDY Lf Q A.1_ SITE/PLOT PLAN 77 :SITE: .�r .;,.... 51-735 VIA ROBLADA WINDOW DETAILS �= -- LA QUINTA, CA 92253 ZONE: RESIDENTIAL Q LOT SIZE: 7,143 SQ. FT. U EXISTING RESIDENCE: 2,780 SQ. FT. Q TOTAL NEW CONSTRUCTION: 13.8 SQ. FT. EFT SCOPE OF WORK. ADDING TWO 30 X 33 -FIXED WINDOWS AT L . ► _ SHEET TITLE: I REAR CORNER OF HOME. PLOT PLAN SITE PLAN S I�U�LDYNGSPECIF"ICATIONS DETAILSUTILITY COMPANITh D R A W N E.A.V. C H E C K E THIS PROJECT SHALL COMPLY .WITH THE FOLLOWING: D EDWIN A. ` VELA - CABLE T.V. TIME .WARNER CABLE DAT E 888.476.4990 2010 CALIFORNIA BUILDING CODE DEC. 1ST 2011 2010 CALIFORNIA RESIDENTIAL CODE -r- S C A t_ E g NATURAL GAS SOUTHERN CALIFORNIA GAS COMPANY CITY OF LA T �. » » SE -,L j __2LBUILDING & SAFE`S C, a . 800.427.2200 2010 CALIFORNIA MECHANICAL CODE , .�., J o e N .AME A + � BRANDY RESIDENCE ELECTRICITY SOUTHERN CALIFORNIA EDISON 2010 CALIFORNIA PLUMBING CODE FOR CONSTRUCT SCALE: _ 1/8"=V-0" 760.369.5403 _. SHEET , 2010 CALIFORNIA ELECTRICAL CODE oar WATER COACHELLA VALLEY WATER DISTRICT l 760.398.2651 2010 CALIFORNIA ENERGY CODE D Ac - O 2010 CALIFORNIA FIRE CODE R 2010 CALIFORNIA GREEN BUILDING CODE — --f --fig-- � �e �...i ri THESE DRAWINGS ARE COPYRIGHTED INSTRUMENTS OF SERVICE AS 091NED BY THE CALFORNIA ADMINISTRATIVE CODE USE OF THE OMER NOTED AT THE EXCLUSIVE SITE INDICATED IN THE DRAVBNG(S) ONLY. THIS DESIGN AND DRAWINGS& ARE SUBMITTED AS RESTRICTIVE AND CON TIAL DISCLOSURE THAT MAY NOT BE USED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE DESIGhffR. DESIGNER SHALL NOT BE RESPONSIBLE FOR COMPLETENESS OF DRAWINGS FOR BIDDING PURPOSES PRIOR TO ISSUANCE OF BUILDING PERMITS. REVISIONS BY (E) SHEAR TRANSFER/TRUSS BLK'G DETAIL LL v PP,OJECT _DATA, SKEET INDEX OWNER: MR. JIM BRANDY Lf Q A.1_ SITE/PLOT PLAN 77 :SITE: .�r .;,.... 51-735 VIA ROBLADA WINDOW DETAILS �= -- LA QUINTA, CA 92253 ZONE: RESIDENTIAL Q LOT SIZE: 7,143 SQ. FT. U EXISTING RESIDENCE: 2,780 SQ. FT. Q TOTAL NEW CONSTRUCTION: 13.8 SQ. FT. EFT SCOPE OF WORK. ADDING TWO 30 X 33 -FIXED WINDOWS AT L . ► _ SHEET TITLE: I REAR CORNER OF HOME. PLOT PLAN SITE PLAN S I�U�LDYNGSPECIF"ICATIONS DETAILSUTILITY COMPANITh D R A W N E.A.V. C H E C K E THIS PROJECT SHALL COMPLY .WITH THE FOLLOWING: D EDWIN A. ` VELA - CABLE T.V. TIME .WARNER CABLE DAT E 888.476.4990 2010 CALIFORNIA BUILDING CODE DEC. 1ST 2011 2010 CALIFORNIA RESIDENTIAL CODE -r- S C A t_ E g NATURAL GAS SOUTHERN CALIFORNIA GAS COMPANY CITY OF LA T �. » » SE -,L j __2LBUILDING & SAFE`S C, a . 800.427.2200 2010 CALIFORNIA MECHANICAL CODE , .�., J o e N .AME A + � BRANDY RESIDENCE ELECTRICITY SOUTHERN CALIFORNIA EDISON 2010 CALIFORNIA PLUMBING CODE FOR CONSTRUCT SCALE: _ 1/8"=V-0" 760.369.5403 _. SHEET , 2010 CALIFORNIA ELECTRICAL CODE oar WATER COACHELLA VALLEY WATER DISTRICT l 760.398.2651 2010 CALIFORNIA ENERGY CODE D Ac - O 2010 CALIFORNIA FIRE CODE R 2010 CALIFORNIA GREEN BUILDING CODE — --f --fig-- � �e �...i ri