Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-0722 (RER)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Applicant: Architect or Engineer: - 0 Application Number: 13-0 00 0 072 2 ) Property Address: 79025yVIA SAN CLARA APN: 649-400-008- - Application description: REMODEL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 15000 Applicant: t/ /,—, I A114- ------------------ LICENSED /1 LICENSED CONTRACTOR'S DECLARATION BUILDING &SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, my License is in full force and effect. ' License Cla B Licen : 805021 �Date��L h Contractor: l OWNER—RUUILDER ECLARATION I hereby affirm under penalty of'perjury that 1 am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or sheds licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 4--- 1—) ..,,1_) I, as owner of the property, or,my employees with wages as their sole compensation, will do the work, and C— the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of - property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 _ 1 I am exempt.under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/01/13 Owner: ALTMAN RESIDENCE 79-075 VIA CAN CLARA LA QUINTA, Contractor: AUo�20 13 yy WHITLEY'S CON TR CTION CORPRTN �iIP7A77775 JACKAL RIC( PALM DESERT, 922 11F 1- (760)341-9480 Lic. No.: 805021 ------------------ WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is . issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier QBE INSURANCE Policy Number EQB0200792 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject tot workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith y ly�yvjttiyrose provisions. - WARNING: FAILURE-TO"SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100;000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct..) agree to comply with all city and county ordinances and state laws relating to building construction, and h, eby a 'thor'ze representatives of this county to enter upon the,above;mentioned property for ins/pectioln purp DateA Signature (Applicant or Agent): �--✓ Application Number 13-00000722 Permit ._ . . . . . ELECTRICAL 2013 Additional desc . Permit Fee. . . 23.83 Plan Check Fee .00 Issue Date . . . .� Valuation 7 0 Expiration Date 1/28/14 Qty -Unit Charge Per Extension 1.00 23.8300 ----------------------------------------------------------------------------- LS ELEC DEVICES, FIRST 20 23.83 Permit . . MECHANICAL 2013 Additional desc Permit Fee . . . . •95.34 -Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 1/28/14 Qty Unit -Charge Per Extension 1.00 35.7500 EA MECH FURNACE 35.75 ' 1.00 11.9200 EA MECH APPL REP/ALT 11.92 1.00 35.7500 EA MECH CONDENSER/COMP 35.75 1.00 11.9200 ---------------------------------------------------------------------------- EA MECH VENT FAN 11.92 Permit . . . PLUMBING 2013 Additional desc Permit Fee . . . . 71.52 Plan Check Fee .00 Issue Date . . . . Valuation 0 Expiration Date 1/28/14'• Qty Unit Charge Per Extension 4.00 - 11.9200 EA PLBG FIXTURE/TRAP 47.68 1.00 11.9200 EA PLBG WATER HEATER/VENT 11.92 1.00 11.9200 EA PLBG WATER INST/ALT/REP 11.92 Permit . . . REMODEL 2013 Additional desc . - o Permit Fee . . 70.07 Plan Check Fee .00 Issue Date . . . Valuation 0 Expiration Date 1/28/14 Qty Unit Charge Per Extension 1.00 48.6200 LS MISC REMODEL, 1ST 100 SF 48.62- 1.00 21:4500 EA MISC REMODEL; ADDL 500 SF 21,45 Special Notes and Comments FIRE DAMAGE REPAIR. RELPACE ROOF TILE, . . LQPERMIT Application,Number 13-00000722 -- -------------- Special Notes and Comments. -------- - ----------------- TRUSSES, INSULATION DRYWALL, ELEC. AND PAINT. PER 2010 CALIF BUILDING CODES. July •31, 2013 2:15:14 PM jjohnson.THIS HOME SHALL COMPLY TO CONY. LIGHT FRAMED CONST. ----------------------------------------------------------------------------- Other Fees BLDG STDS-ADMIN (SB1473) 1.00 PLAN CHECK, ELECTRICAL 23.83 PLAN CHECK, REMODEL 150.15 PERMIT ISSUANCE M/P/E 90.57 PLAN CHECK, MECHANICAL 45.29 - PLAN CHECK, PLUMBING 66.75 STRONG MOTION (SMI) - RES 1.50 Fee summary Charged Paid Credited Due Permit Fee Total 260.76 -00 .00 260.76 Plan Check Total .00 .00 .00 .00 Other Fee Total 379.09 .00 .00 379.09 Grand Total 639.85` .00 ..00 639.85 LQPERMIT - fff RF E IV E� . Bin �. Oty.'of La Qurnta -. Buttdt ig 8r Safety DivisionJUN 04 201 Permit # �. ' ... , P.O. Box 1504, 78-495 Otte Tampico .' La.Quinta, CA 92253 - 777-7012 CITY OF LA QUI TA ` (760) Building Permit Applicatlon and Tracking MUNITY. DEVEL PMENT ' Project Address: C Owner's Name:. A- P. Number. Address: '� R U Legal Description: Ci ST Zi , Contractor. Telephone: d a s / Address:-7cl J - r Project Description: E, City, ST, Zip: t 22( P C A t Q' Telephone: 7�ijvo2 � b i fY 1 G State Lic. # City Lic- #; , Arch-, Engr., Designer: L; City., ST, Zip4w 06 D� Telephone: - Construction Type:. Occupancy: - r State Lic. #: ' _ Project type (circle one): New Add'n ',Alterepair Demo Sq. Ft.: I/ # Stories: # units: Name of Contact Person: E, Telephone # of Contact Person: ? D S Estimated Value of Proj APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd TRACKING PERMIT FEES - Plan Sets Pian Check submitted Item Amount Structural Cal cs. Reviewed, ready for wrrecdoas Plan Check De wsit. . Truss Cates. Called Contact Person3 Plan Check Ba:ance _ Title 24 Calci. - ' Plans picked up Constmcdon Flood plain plan Plans resubmitted Mechanical Grading plan 2id Review, ready for correctio sfissue Electrical j Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.KL ` H.O.A. Approval Plans resubmitted Grading IN HOUSE:- 7jd Review "CC on Developer Img act Fee Planning Approval n' A,I.P.P. Pub. Wks. Appr Date of permit issue School Fees , Q RoTotal Permit Pees vim. wr wt 4 .. I�o�Ir l _ BUILDING ENERGY ANALYSIS REPORT ' PROJECT: . •,Altman Residence (Casita Fire Damage Repair) ' *1 _ 79075 Via San Clara La Quinta , CA 92625 Pro'ect Desi' ner: ' ` NOiio 1 9 1SN00 u0 j , • 03 08d Concorde Enterprises a D A13Jb'S ON15,9, mino Del Rio. South, Suite 332 . V1Nino 1140 A190• San Diego, CA 92108. R ,619-516-3377 r: ' ' Report Prepared by: y, David, Schneider (CEA & CEPE) • CT Title 24 Energy Consultants r P.O. Box 71.1307 San Diego, CA 92171, f _a . - 619-504-5610. 2]] i } S K IV ED • ertl fied HERS Rater s' CaliforniaKorn Efficiency Rating Service JUL 1 0.2013 aR . f Dyid:Schne{der" • 1�1 G j CCN96924316 - ,,CI1Y OF LP, QUINTA JJJJl� ncil/vacnrr�.ora,w { CONSULTANTS fiilrhng / ntiehipe COMMUNITY DEVELOPMENT 4 ' 7trermal6ypaxvcheckhi Job Number. " _ LSlbrCerrifredRater 4 r #.- 1- "L.13-147 1 i r r Ccrtficd GaLCEI�'I'S itatec } `✓ . .' Date: "~ caHfomla Association of Building Energy consultants David Schneider #11108-08-261 & MR0848-540 ' ,-- The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 1562A RunCode: 2013-06-04T08:05:1, ID: 13-147 _ ,: ,. '.� ,y �� r Y � ' � � � PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Altman Residence (Casita Fire Damage R Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 5/4/2013 Project Address 79075 Via San Clara La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1 442 Addition 0 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Slab Unheated Slab -on -Grade None 442 Perim = 87' Existing Wall Wood Framed R-19 550 Altered Wall Wood Framed R-19 127 Existing Roof Wood Framed Attic R-30 442 Radiant Barrier New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Front (S) 20.0 0.580 0.65 none none Bug Screen Existing Rear (Nlh9 33.3 0.580 0.40 none none Bug Screen Existing Rear (N) 24.0 0.580 0.65 none none Bug Screen Existing Rear (N) 20.0 0.990 0.74 none none Bug Screen Removed Rear (N) 20.0 0.390 0.37 none none Bug Screen New Right (E) 9.0 0.580 0.65 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Exisitng HVAC System Ducted Ducted Attic, Ceiling Ins, vented 6-.0 Altered WATER HEATING CITY OF LA Qty. Type Gallons Min. Eff Distrib iplJ QUIrSt$t s 0 cY DEPT. Eon r, r :. ,/UN DATP Energ Pro 5.1 by Energ Soft User Number: 1562A RunCode: 2013-06-04T08:05:11L—�(p: 13-147-"'— '-.. ---_ Page of 10 PERFORMANCE CERTIFICATE: Residential I (Part 2 of 5) " CF -1 R. Project Name Altman Residence (Casita Fire Damage Re Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 6/4/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof New R-30 Roof (Radiant Barrier) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. R - � f HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF74R form for each of the measures listed below for final to be given.. CITY OF LA 01 uNmIft bUILDIIVR- & SAFETY DEPT. ED FOR Ca�,i«, t'V 44gh EnergyPro 5.1 by EnergySoft User Number. 1562A RunCode: 2013-06-04708:05:11 9 ID: 13-147 AtA of 1 RTE ' PERFORMANCE CERTIFICATE: Residential (Part of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date Altman Residence (Casita Fire Damage Re ❑ Multi Family m Existing+ Addition/Alteration 6/4/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/V- r Space Heating 8.45 6.30 2.15 Space Cooling 140.47 136.77 3.71 Fans 31.71 30.74 0.97 Domestic Hot Water 50.15 50.15 0.00 Pumps 0.00 0.00 0.00 - Totals 230.79 223.96 6.82 Percent Better Than Standard: 3.0 BUILDING COMPLIES -NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Ar--a Area Number of Dwelling Units: 1.00 (S) 221 20 Fuel Available at Site: Natural Gas M9 90 0 Raised Floor Area: o (N) 336 77 Slab on Grade Area: 442 (E) 136 9 Average Ceiling Height: 8.1 Roof 442 0 Fenestration Average U-Factor: 0.54 TOTAL: 106 Average SHGC: 0.52 Fenestration/CFA patio: 24.0 REMARKS NOTICE: THE TITLE 24 ENERGY LOAD ANALYSIS IN THIS REPORT IS FOR TITLE 24 ENERGY CODE COMPLIANCE PURPOSES. FINAL SPECIFICATIONS AND SELECTION OF HVAC EQUIPMENT IS THE SOLE RESPONSIBILITY OF THE MECHANICAL ENGINEER OR INSTALLING HVAC CONTRACTOR. THIS RESPONSIBLE PARTY SHOULD PERFORM BOTH MANUAL "D" AVD MANUAL "J" CALCUATIONS FOR PROPER SIZING AND SELECTION OF MECHANICAL EQUIPMENT. STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the EfficiencyStandards of the California Code of Regulations. 9 aavreMelly" rcRos os-ss� &saRos os soo; 8307 .... The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author ................ ............ Company Title 24 Energy Consultants _ 6/42013 P.O. Box 711307 David Schneider &C7"Sign'�� Address Name (CEA Ci /State/Zi San Diego, CA 92171 Phone 619-504-5610 Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) CIN Company , Concorde Enterprises of 1 BUILDING � QUTA 7 Address 3505 Camino Del Rio. South, Suite 332 Name Raj Narayanan City/State/Zip San Diego, CA 92108 Phone 619-516-3377 igne�l��►®�bse se PT Date FO �UC77� Ene Pro5.1 b Ene Soft User Number: 1562A RunCode: 2013-06-04 08'' 5Ck /D: 13-147 Pdqe 5 of 10 - B1-" CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R Project Name Altman Residence (Casita Fire Damage Rep Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addit:on/Alteration Date 6/4/2013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appencix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 442 0.730 None 0 180 Existing 4.4.7-A1 Exisitng Casita Floor Area Wall 201 0.074 R-19 200 90 Altered 4.3.1-A5 E=4.3.1 -A5) Exisitng Casita Floor Area Wall 901 0.074 R-19 1 290 90 Altered 4.3.1-A5 E=4.3. 1 -A5 Exisitng Casita Floor Area Wall 135 0.074 R-19 335 90 Altered 4.3.1-A5 E=4.3.1 -A5 Exisitng Casita Floor Area Wall 124 0.074 R-19 1 1 20 90 Altered 4.3.1-A5 E=4.3.1 •A5 Exisitng Casita Floor Area Wall 127 0.074 R-19 110 90 Existing 4.3.1-A5 Exisitng Casita Floor Area Roof 442 0.031 R-30 335 26 Remove 4.2.1-A20 Exisitng Casita Floor Area Roof 442 0.031 R-30. 335 26 New 4.2.1-A20 Exisitng Casita Floor Area FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC2 Azm GlazingType Location/Comments 1 Window 5.0 0.580 Default 0.65 Default 200 Existing Non -Metal Window Exisitng Casita Floor Area 2 Window 15.0 0.580 Default 0.65 Default 200 qExisting Existing Non -Metal Window Exisitng Casita Floor Area 3 Window 33.3 0.580 Default 0.40 NFRC 335 Existing Non -Metal Sliding Do Exisitng Casita Floor Area 4 Window 15.0 0.580 Default 0.65 Default 20 Existing Non -Metal Window Exisitng Casita Floor Area 5 Window 20.0 0.990 Default 0.74 Default 20 Removed Front Door Exisitng Casita Floor Area 6 lWndow 20.01 0.390 NFRC 1 0.37 NFRC 20 New Sierra Pacific Windows & Door Exisitng Casita Floor Area 7 Window 9.0 0.580 Default 0.65 Default 20 Existing Existing Non -Metal Window Exisitng Casita Floor Area 8 Window 9.0 0.580 Default 0.65 Default 110 Existing Existing Non -Metal Window Exisitng Casita Floor Area (1) U Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC Hot Wd Ove hang Left Fin Ri ht Fin Len H t LExt RExt Dist Len F t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 JBug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.761 1 7 Bug Screen 0.76 8 Bug Screen 0.76 Ener Pro 5.1 by EnergySoft User Number: 1562A RunCode: 2013-06-04708:05:11 ID: 13-147 Pae 6 of 10 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Altman Residence (Casita Fire Damage Re Building Type © Single Family ❑ Addition Alone ❑ Multi Family ® Existing+Additon/Alteration 161412013 Date BUILDING ZONE INFORMATION System Name Zone Name New Floor Area ft Existing Altered Removed Volume Year Built Exisitng HVAC System Existing Casita Floor Area 442 3,580 1996 Totals 01 4421 0 0 HVAC SYSTEMS S stem Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Exisitng HVAC System 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Cooling Duct Duct Location R -Value Ducts Tested? Status Exisitng HVAC System Ducted Ducted Attic, Ceiling Ins, vented 6.0 ❑ Altered WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50 0.58 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft C 0 i� N a S Pipe System Name Length Pipe Insul. Diameter Thick. Qty. HP Plenum Outside Buried ❑ ( LA Q ❑ ay 0 N.a"< J( l� Ry F� f r l.Ji.•f.t)�.Iz~r V EnergyPro 5.1 by Ener Soft User Number.' 1562A RunCode: 2013-06-04708:05:11 ID: 13-147 1 L ASOUKMI 10 MANDATORY- MEASURES, SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name ; Date Altman Residence (Casita Fire Damage Repair) 6/4/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF71 R -ADD, or CF- ' 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. ; Building Envelope Measures: ' 116 a 1' Doors and windows between conditioned and unconditioned spaces are manufactured to limit aii leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration'that meets the requirements of §10-111(a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. J 118(a): Insulation sp ecified or installed meets Standards for Insulating Material. Indicate -type and include on CF -613 Forma §118(i): -The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the - installation of a Cool Roof is specified on the CF -1 R Form. ' *§150(a): Minimum'R-19 insulation in wood -frame ceiling ore uivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. " *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when s eci`ied on the CF71R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor perme-ance rate is no great6r than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 1 50 e 1 A: Maso nry or factory -built fire laces have a closable metal or glass door covering the entire opering of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six sgPare inches in area and.is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. ' §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. r §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air. release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of 113(65. §115: Continuously,burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances - (appliances with -an electrical `supply voltage connection with pilot lights that consume -less than* 1.50 Btu/hr are exempt),"and.pool and- s a heaters. ' 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. ' 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 2(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped .with insulation havingan installed thermal resistance of R-12 or greater. a §1500)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water . tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.. ; §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatingsections of hot water pipes are insulated per Standards Table 150-B.. . §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulatedbetween heating source and indirect hot water tank'shall be insulated to Table 150-B and Equation 150-A. t. L r §1500)2: -Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. , 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, e i tenance; and wind` §150.0)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor et nr's si in conditioned space. A 150(j)4: Solar water-heatin' systems and/or collectors are certified bathe Solar Ratin d Certi ica ist`o ra . A .•� ' ., - - • '� FSR ����./�t•P,7; ; •~- " { -• .:. EnergyPro 5.1 byEnergySoft •-' UserNumber.• 1562A r RunCode: 2013-06-04708:05:11 ID: 13-147 °��' 1 �Yage 80 10 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Altman Residence (Casita Fire Damage Repair) 1 6/4/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a rninimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements o- UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool s stems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. §150(k)3: The wattage of permanently installed luminaires shall be determined_ as. s _ecified,by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Wafts or greater shall be electronic and shall have an outout frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire orexhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a Jine-voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. §150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). §150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens &'hall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 #t2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square.feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more thf 2pat#�Saf pQr of �� 11'' illuminated cabinet. �J OUILDING & SAFETY p 0 `pP,REPT. CONSTRUCTION EnergyPro 5.1 by EnergySoft User Number: 1562A RunCode: 2013-06-04708:05:11 I DAT ID: 13-147 Page 9 of 10 W MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Altman Residence (Casita Fire Damage Repair) 1 6/4/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms: closets and utility rooms shall be high efficacy. EXCEPTION. 1: Permanently installed low efficacy luminaires shall be allowed provided that they are contrclled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact IIC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass "switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch #rhich bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall -,omply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildi igs with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CITY OF LA BUILDING & SAF E r.•YSDE •'Z . APP •� cedffled RO CA"-� FGR CONST. 07-16 9 s .R ��. 1p�LIFOR A CaUfornla A••odatten of Building Energy CmreWtanta • ••+ - ' �(•�'!••..•s+ •��Y David Schneider DATE - — — - - — - B'•' SIDE #R08-08-261 & #NR08-08-540 — EnergyPro 5.1 by EnergySo/t User Number. 1562A RunCode: 2013-06-04T08:05:11 ID: 13-147 Page 10 of 10