Loading...
05-5350 (SFD)P.O. BOX 1504- 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA,92253 BUILDING & SAFETY. DEPARTMENT; BUILDING PERMIT Application Number: 05-00005350 Owner Property Address: ,. 52839 VIA SAVONA DREWES APN: "'7727410-99.9-21 -298943- 3870 CHANNEL DR D . Application description: DWELLING - SINGLE FAMILY DETACHED SACRAMENTO, CA 9584) Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 505254 Contractor: Applicant: Architect or Engineer: MONARCH HOMES DESERr DI 73290 EL PASEO, SUIEE.:.# PALM DESERT, CA 92260 — (760)568-3905 C LiC. No.. 457228 VOICE (760)•777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/27/06 e MAR 3 0 2006 ' DI LA QUINTA .LICENSED CONTRACTOR'S DECLARATION - WORKER'S COMPENSATION DECLARATION " I hereby affirm under penalty of perjur that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: - .Section 7000) of Division 3 ofifsiness and Professionals Code, and my License is in full force and effect. I have and willmaintain a certificate of consent to self -insure for workers' compensation, as provided License Class: B License No.: -457228 _' for by Section 3700 of the Labor Code, for the performance of the work for which this permit is !� s I - 0-0 l Contractor �'gr1., issued. ' I have and will ma intain-workers' compensation insurance, as required by Section 3700 of the Labor - r - !'buJ .fie Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION - insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the .. Carrier STATE FUND _ Policy Number - 0028122-2005 . following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any mann so as to become subject to the workers.' compensation laws of California, permit to file a signed statement that he.or she is licensed pursuant to the provisions of the Contractor's State _ and agree that, if I hould becom�gSSubject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or, 3700 of the Labor od I for it o ply wish those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (8500).: �`� -Applicant (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and A"z, 7— ' ' the structure is not intendedoroffered for sale (Sec. 7044, Business and. Professions Code: The WARNING: FA LURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL' Contractors' State License Law does'not apply to an owner of. property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS (8100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or - improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT (_) I, as owner of the property; am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and -restrictions set forth on this application. property who builds or improves thereon, and who contracts forthe projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for ' pursuant totheContractors' State License Law.l. - whose benefit work is performed under or pursuantto any permit issued as a result of this application, (_) I am exempt under Sec. B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City Date:, Owner: CONSTRUCTION LENDING AGENCY I hereby. affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERNIIT f of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work.for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to uildin s ction, and hereby authorize representatives of this county to enter upon the above-mentioned pr er or in p es gna re.(Applicant or Age . e0 Application Number.. 05-00005350 Permit. BUILDING PERMIT . Additional desc . Permit Fee ,. 2057.50 Plan "Check Fee :-., "' 1337.38 .Issue Date Valuation.`. 505254'. Expiration Date 9/23%06 Qty, Unit Charge Per Extension' BASE FEE. 2039.50 6.00 3.0000 THOU' BLDG 500,001-1;"000;000 18.00 Permit. MECHANICAL Additional desc . Permit Fee 132.50. Plan Check. Fee 33.13 Issue: -Date Valuation 0 Expiration Date.. 9/,23/06 Qty Unit Charge Per Extension , BASE FEE 15.00 .4.00 ' 9.0000 EA MECH FURNACE -<=100K 36.00- 4.00 9.0000 EA MECH .B/C <=3HP/100K BTU 36.00 6.00 6.5000 EA MECH VENT FAN 39.00 . 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit ELEC-NEW RESIDENTIAL.--", ESIDENTIAL"- Additional Additional desc . Permit Fee . . 250,89 Plan Check Fee 62.72 Issue Date . . . Valuation 0 Expiration Date .9/23"/06.. Qty Unit Charge Per Extension' BASE FEE 15.00. 5627.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 196.95 1197.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 23.94 1.00 15.0000 EA ELEC TEMPORARY.POWER POLE"' 15,00 Permit PLUMBING Additional desc .". Permit Fee . . . . -225.75 Plan Check Fee ." 56.44" Issue Date Valuation 0 Expiration Date 9/23/06 Qty Unit -Charge Per Extension BASE FEE 15.00 24.00 6:0000.EA PLB FIXTURE 144.00 LQPERMIT .. .. .. - .. .. - Application Number 05=00005350 Permit PLUMBING Qty Unit 'Charge 'Per Extension 1.00 15.0000 EA PLB.BUILDING.SEWER. 2.00 7.5000 EA PLB WATER-HEATER/VENT ; 15:-00 -1.00 3.0000'EA PLB WATER INST/ALT/REP .3.00 1.00 9.0000 'EA PLB .LAWN SPRINKLER SYSTEM" 9.0.0 . 13.00. .7500 EA PLB 'GAS`PIPE. >=5 .. 9.75 1.00 15.0000 EA. PLB GAS METER 15.00 Permit •GRADING PERMIT - Additional desc . Permit Fee . . . 15.00 Plan*Check'Fee .00 Issue Date . . . Valuation . . . . 0 Expiration -Date '9/23/06 Qty -Unit Charge Per_ Extension BASE FEE 15.00 Special.Notes and Comments. 5627 SQ. -FT. SFD: PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL/SPA OR DRIVEWAY APPROACH. March 27, 2006 .2:51:11 PM SRUBIO Other Fees . . . . . . . ART IN PUBLIC:PLACES-RES 763.13 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 480.00. ENERGY REVIEW FEE 133.74 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF'PARKS/REC - RES 892.00 -STRONG MOTION (SMI). --.RES 50.52 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1666.00 Fee summary Charged Paid ..Credited Due Permit Fee Total 2681.64 :00" :00 2681.64 Plan Check Total 1489.67 500.00 00 989:67 ; Other Fee Total 4643.39 .00 .00 4643.39 Grand Total 8814.70 500.`00 :00 8314.70- " P.O. BOX 1504 Building �A ��7.8.495 CALLE TAMPICO Address Qi VvI PINTA, CALIFORNIA 92253 Addressy 3 / 50 D(/1/53 APPLICATION ONLY /Prr� �Gtl�s BUILDING: TYPE CONST. OCC. GRP. A.P. Numberwo lzip,sG,,, Tel 're 7 1 i�Ci'/� 4-04 SCn Legal Description Project Description�� PN ?72- ylo- 9Gg 1-a5 State Lic. City Sq. Ft. No. No. Dw. Arch., Engr., New)' El Alter ❑ Repair ❑ Demolition ❑ Designer Fddress // OA City Zip State V Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractors) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason WORKER'S COMPENSATION DECLARATION hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit whenproperly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Qp , Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. e Grading Driveway Enc. Infrastructureimp PT. TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE- / I ' . Coachella Valley Unified School District This Box For District use only '83-733 Avenue 55, Thermal, CA 92274 DEVELOPER FEES PAID (760) 398-5909 — Fax (760) 398-1224. , r• CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Residence at the Hideawa Date: March 30, 2006 Owner's Name: Mr. Mrs. Drewes Phone No. 578-4079 Project Address: 52-839 Via Savona La Quinta, CA Project Description: 1 SFD APN: 772-410-999 Tract #: " g , Lot #'s• 2J 2 - C_,' Type of Development: Residential XX Commercial Industrial Total Square Feet of Building Area: -5,627 sq. ft. ti Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: March 30, 2006 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval ..Prior to 1/1/87 Requirement Number of Sq.Ft. 5,627 Amount per Sq.Ft. $2.88 ry - Amount. Collected - $16,205.76 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst: Supt:, Business Services ' Certificate issued by:, . Elvira Mattson, Office Technician Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES* ' Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 6,6020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this 'time or in whole or in.part prior to issuance of a Certificate of Occupancy. As•in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. ' 1L.':ciroydacsidcvlecSiCcrtiiicatc uPcamplimcr ii)rm ad�Ias'P(:l Ii;SG.doa _ 1/16/03 T J AREA: AMOUNT LEVEL ONE AMOUNT: - LEVEL TWO AMOUNT: MITIGATION AMOUNT: a COMM/IND. AMOUNT: nATF- RF.f.FJPT•.f.HF.f.K N• INITIAIS �� uG./ J/LUUD 1Lv: S4 FAA i FIDELITY NATIONAL TITLE COMPANY SUBDIVISION DZPARTMLNT WHEN RECORDED MAIL TO: Mr. & Mrs. Drowns 3570 Channel Drive i� Sacramento, CA 95691 1a002/003 FIDELITY PALM DESERT i.FNT LQ a W002/003 DOC "a 2004-0333090 M/05/2004 08:000 Fee.1s.00 049% 1 Of 4 Doo T Tax Paid Recardod In Official Ramrde eauney of Rlvwroick Gary L Oro* Raaonor, County Clark d Raoortfar I III 11111 IN 1111111111111111 I�III Inl flip MAIL TAX STATEMENT TO: w s u .I -• - t SAME AS ABOVE — R -- — _— GOw IAO Af.I+711D wCeG .EXAM DOCUMENT TRANSFER TAX S e69.00 f� XX Computed on the consideration or value of property conveyed, OR/� I v Computed on the consideration or value less liens or encumbrances I ^� remaining at the time of sale. i� Signature of Declarant or Agent determining tai -Firm Nemo .9A'GRANT DEED' FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND. LA QUINTA PARTNERS, LLC, a Delaware limited liability company ("Grantor'), hereby GRANT(S) to John F. 'Drewes and Susette R. Dreves, trustees for THE DRMS FAMILY TRUST dated February 26,1999 ("Grantee"), the real property located in the City of La Quinta, County of Riverside, State of � California, described as: ` See Legal Description attached hereto and incorporated herein as Exhibit "A". SUBJECT TO ill matters of record including, without limitation, the covenants and agreements described in Exhibit "A" attached hereto, Dated: 1 ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company By: Nationwide Realty Investors, Ltd. an Ohio limited liability company ' its managing me bar olle By:00, "0 Z." Jose . Arenson Authorized Representative prop: Lot 21 of Tract 29894-3-,RV.2004 00333090 f u2/PU/Z000 ' 11:54 'NAS[ 16003/003 FIDELITY PALM DESIJRT ->' FNT LQ IBJ 003/003 EXHIMiT "A°' . " , Legal Desctiotion At .Parcel No. 1: Lot 21122, of Amended Tract No. 29894.3, in the City of La Quirlta, County of Riverside, State - of California, as per Map recorded in Book 351, Pages 35 through 48. inclusive of Maps, in the Office of the County Recorder of said County and shown on Grant Deed recorded April 13; 2004 as Instrument No. 2004-0266745 of official Records. • Grant Deed"reflects Panel Merger No. 2004-437, as approved by the City of La Quinta - EXCEPTING AND RESERVING THEREFROM TO GRANTOR. and its successors, assigns, invitees, licensees and employees, together with the right to -grant and transfer. all or a portion of the same, all easements and rights for ac. cws,•ingress, egress, encroachment, maintenance, drainatge,/support, sad for other purposes over the Association Maintenance Areas and other portion of the Lot, reserved to Grantor in the following instruments: 1. The Amended and Restated Declaration of Covenants, Conditions attd Restrictions and Reservation of Eakments for1be Hideaway Owners Association (as amended or supplemented, the "Deelmdoo'), recorded on December 13, 2002, as instrument No. 2002- 745939, of Official Records of Rivemside County, California (the "Official Records"); 2. The Supplementary Declaration'of Annexation of Property, recorded on March 4, 2004, as Instrument. No. 2004-015198 1, of Official Records of Riverside Country, California. FURTHER RESERVING THEREFROM, the right to enter the Lot for a term of twelve (12) months following the recordation of this Grant Deed, to complete and repair any improvements or landscaping located thereon as determined necessary by'Grantor, in its sole discretion. in order to comply with requirements for the recordation of the Final Tract Map, the grading of said Tract and/or in compliance. with the requirements of applicable governmental agencies. Such entty'by Grantor shall be preceded by reasonable notice to,Grantee.before such r entry. If this reservation of right of entry is not complied with b Grantee, • this right of en Y Grantor may enforce .° Bh try jh'a court of law, Grantee shall be responsible for all damages arising out of? said breach including attorneys' fees and court costs. This reservation of right of entry shall automatically expire twelve (12) months from the recordation of this Grant Deed, Parccl No. 2: Nonexclusive easements for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as described in the Declaration, _ prop: Lot 21 of Tract 29694-3 - RV;2004 00333090 3 of 4 r Plan check No. 05-53-50, VCA File No. LQ- 181"09 CITY OF LA QUINTA PLAN CHECK CORRECTION LIST The Flying Buttress March 17`h 2006 73661 Highway 111 Suite G Palm Desert, California 92260 Structural Review Only PLAN CHECK NO. - 05-5350 THIRD CHECK/APPROVED ADDRESS 52839 Via Savona OCCUPANCY R -3/U-1 SCOPE OF WORK NSFR 5627/1182 TYPE -OF -CONST.: V -N The submitted plans and specifications have been reviewed by the VCA CODE GROUP. In our „ professional.opinion,the plans are in substantial conformance with the building codes and regulations adopted by the CITY OF LA QUINTA and the State of California Amendment.' APPROVAL FOR BUILDING PERMIT IS HEREBY. RECOMMENDED SUBJECT TO OBTAINING APPROVALS/CLEARANCES FROM. ALL APPLICABLE CITY DEPARTMENTS, AGENCIES, AND ASSOCIATIONS. Plans checked by: Timothy Koutsouros VCA CODE GROUP 2200 W Orangewood Ave, Ste 155 Orange, CA 92868 (714) 363-4700 ext. 758 VCA File No. LQ- 18109 n CITY OF LA QUINTA - PUBLIC WORKS/ENGINEERING DEPARTMENT '"M v . GREEN SHEET PUBLIC WORKS CLEA RANGE) FOR BUILDING PERMITS Form updated & effective 8/25/2005 A PM Please DO NOT submit 'the Green Sheet (Public Works Clearance) Packet to the Public Works/Engineering Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to Applicant. Green Sheet approvals will be forwarded to the Building Department directly.by Public Works. w Date: 2 2g Developer: 0O,L�Leu/ L��ES �.klG . �� QE. Tract No.: 21-3' Tract NameMA3 3 S/ 3S- os Lot No.(s): 2✓ z v c . Address(s): 5 2- . - Y3- P11 A !Sa ✓o<l4 4EQ*� The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the Building/Safety Department. CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4 AND #5'BELOW TRACT HOMES: PROVIDE ITEMS #1, #2, #3, #4 (AS APPLICABLE) AND #6 BELOW COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1 #2 #3 AND #5 BELOW. 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for �( approval, please withhold green sheet submittal until. a Pad Elevation Certificate can be /Nr+ provided. 2: Attach geotechnical certification of grading plan compliance. 3. Attach recorded final map showing proposed building locations are legal lots. /A-1 t3�4 P6,17. 4. Attach a completed <1 acre per lot or infill project Fugitive'DustControl project information form, PM 10 plan & agreement or provide alternative & valid City approved PM 10 plan set. reference number or hard copy. plan. PM10 plans for commercial and residential developments (beyond 1 lot) are submitted separately with grading plans and are subject to additional requirements. 5. _Attach. an approved precise grading plan for the building location(s).. AO flood zone developments will require an approved floodplain development plan. is 6c.a4. 6. Attach an approved rough grading plan for the building location(s). I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed. building(s)/structure(s) on the subject lot(s). Pursuant to m f ndings, the above oject may be released for building permit issuance. Recommended by: Dated: d 4, Declined for approval for reason(s) as follow(s), please correct and resubmit: TAPWDEPT\STAFRGoble\Grecn Sheet PW ReleasA050824GREEN SHEET COVER.doc y: City of La Quinta - PM 10 Project Information(<l acre per Lot or Infill Project)* Pagel of 3 Form updated & effective 8/25/2005 Project Information Project Contractor: Project Phase %YlO L1 I& O<D "C—s k i G _ 7� E2' (✓. Project Phase (Check One): Project Name: Project Tract Number: e D<Construction ❑ Demolition Lot Number(s): z.f ZZ. c •Anticipated Start Date: 3 ' Project Street Address: A Q :� c•. z -d—" Anticipated Completion: IZ - 31 • o� , Total'acres in active construction (<1 acre per Lot): , ('LPT —SPJ40E • ' Fi�u�c.. iZESInF�� Proj ct Contact Please Note: Dust control is required 24 hours a day, 7 days a week, . Information regardless of construction status. Person listed below is responsible for -dust control during business and non- business hours. Name: Title: Company Name: AJC . Mailing Address: 2 3 C [_ IAsec, City:.�ccsu SES r State: G�-� tr—• Zip Code: Ag Primary Telephone 7Go . S�8 • 3 � o S • Number: Fax:7l 0 • S� 3 24 Hour Access/Emergency 71ao . S- 2,9 • 4029 Phone: • . Cell Phone: -2 (fl o 1572 41079 PM -10 Certificate Number: D— io — 2. * Expanded PM 10 plans for commercial and residential developments > 1 acre are required by the City of La Quinta. T:\PWDEPT\STAFRGoble\Green Sheet -PW Release\050824MINI PM 10 PACKET GREEN SHEET.doc - . r'• � - Site S ecifreement Pa2e 3 of 3ic Construction Phase PM 10 A • City of La Quinto p E Agreement updated & effective 8/25/2005 The signature of the property owner (or authorized representative): i • Shall. act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to'AQMD•Rules 403 and 403.1; Shall constitute and agreement to comply with all project conditions 'as identified in the approved dust control plan; The property owner.(or authorized representative): • Acknowledges that dust control is required 24 hours a day, 7 days a week, throughout the ` period of project performance, regardless of project size or status; • Shall ensure that each and every contractor/subcontractor and all. other persons associated with the project shall be in continuous compliance with all requirements of the approved dust. control plan; • Shall -take all necessary' precautions to minimize dust,' even if additional measures beyond those.lisfed in, the dust control plan are necessary; • Shall authorize representative of the City/County to enter upon the above mentioned property for inspection and/or abatement purposes; and a , • • Shall hold harmless the City/County and its representatives from liability for any actions . related to this dust control plan or any City/County initiated abatement activities. Signature of Property Owner or. -Authorized Representative Printed Name �i�o j �� GGC��J� �C� . • 2 • Z-8 • o Co . Title Date Company i JCM Inspections 39725 Garand Lane Suite F - Palm DesertCA 92211 INSPECTIONS Phone: 760-345-5554 =-,Fax: 760-772-3895 INSPECTIONS EPDXY INSPECTION'REPORT Date: ect Name: r , Project No: Project Address: (City: Sa= �3 V S C, a.C.. u .'l o. \A1 Client: Sub -Contractor: ft CoYI)C er _ General Contractor: Architect:', ._ Structural Engineer: \ \ ©4nchor Bolts E] Rebar r' > © IBC ' Epoxy Type ` ] \.n1 Son � c0 r1 cv e. E] Title 24 . ; Other: EpoxyShelf,Life:�`p6$ Unresolved Items: L��a� ) �rnnn�Ci+SSQOIt'�� RcushscX `� Wece:�f Hole CleaninIQ ©None dd�gMethod(s):�o�J� h, V ` r ❑ See Below Description of Work Inspected: \ VJt ��"�e T r�rofeJ? "C oav�Cu�, n\ -ems i & �3c�'1, t. �%2k C. �`i�e o: c e:4 n '% <�: •S E' r,-� �1 a i r►C � Y� A .S\ �, \' � o O W � in C,c 't r�,2C '. c C�. e Ck, s'. c//�._• Go.ca�Q :. c tau. 1� Td GC VA oro j - >-,� eua 4z -o. rc��1 e� < Col �+n Covn C /� � ^Cyut e — � ��r'� •o f co\tlr�1'1 \ \ —�/�^� , c'•ot�� Q u`l.� �n. ei3C:rnn —+— tC\S�e-Ne_0.: NCS -co"O-co" Qui �.: Work complies with written approval from Structural Engineer.and ICC Evaluation Report #. I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved s, specifications _applicable building laws.. Final report issued at project completion. Inspector: Jack C. Millin ICC Certification No: 0842216-49 1 Contractor's Representative: Copy 1 JCM inspec 'ons Copy 2 Project Superinterident Copy 3 Governing Agency Page of 1 f - ,JCM Inspections, -T 39725 Garand Lane Suite F I Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS REINFORCED CONCRETE INSPECTION REPORT Date, y_r x Project Name: Project No: 17r0 wP5 fJP1., -4 ado ����q 14-YAt' Project Address: City: �Z' � 4Q 1/ is 5 c 1/'0 1, b a (// �t.r•'�,^!u / A E]1 IBC E] Title 24 Other: Client: Sub -Contractor: Q u/ (Aply R' C 0&1 C (' p 'F P General Contractor: Architect: D Structural Engineer:I ln/iIrf CO1A5`il�a�t,0, �4CI i�l�l.�i� ///ottt•S'' io-e1+�rV � ) Slump (inches): Supplier: A - ( Time Sampled: A ,- ty % M i Mix Design: Time in Mixer (min.): (9 D ,' Specified Strength (PSI): ?a oo o Water Added @ Jobsite (gals.): -- Addmixture: �i Concrete Temperature (F): 5 Truck #U 5 S Ticket #: Z,-7 q 7 y,? Ambient Air Temperature (F): ° Field ID Marking: her:eat W;at erj Unresolved Items: �0 None ❑ See Below Location of Sample: iq T I l,1 e, -Jr `f' No Samples Taken Description of Work Inspected: r A 00 !nV /.7(,4 n l of r e, r 40 lr A b-12 A� h� two S 0is4 V7e7 1, s ,o V �-rrf , A 5;'101r AI J ,f1 % 4- (1 -,,Ps C -i- 1> - I, Y --c r i M ,..-A n 6 4 P -4 G4 a ,'-1 Li 16 -i. 4_ c .l 1 ' C 7i5 �4 1.1 (; / 01 I , / �- In 'P 40 V �•,� 1 r� f / r W� t I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications applicable building laws. Final report issued at project completion. Inspector: ti 4 l/ �� ,� / Contractor's Representative: Copy 1 JCM Inspections Copy 2 Project Superintendent f V / v r Copy 3 r Governing Agency Page 1 oft "e r 91 A'...i'OF A.. .) Bin # r.. , 7'P.O: Permit.# 0'5" 5350 City of La Quinta Building 81 Safety Division Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: • ,a V) /.l 5Yk%kJ/X Owner's Name: _ A. P. Number:G,�G�D�Gj, a a� y - 3 Address: Legal Description: Contractor: A�I- City, ST, Zip: Telephone:(Y.Altj TV Address:� '�40 b /f Project Description: City, ST, Zip: /�Ll�l D*I GA Iq(� Telephone: lJs ��/��C� %7-J, . �G<//.�/JOGv /��l-aV �O tri CoA f/�L State Lic. # : City Lic. #: Arch., Engr., Designer: /W tv Div ' (' G.ft?46;67_ 5WZ Address: A 64 -sires 'r 6A446c City, ST, Zip: //la aa7o . oD%>/✓G ci/ Z C�' E �� C1Gr C Telephone: �j , 7 �!J ?j� State Lic. #: Name of Contact Person: Construction Typ77- 414 Occupancy: Project type (circle one): ew Add'n Alter Repair Demo Sq. Ft.: 2- # Stories: # Units: Telephone # of Contact Person: ?j (moi jibZj Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan SetsPlan Check submitted,-----,, Item Amount �- Structural Calcs. Reviewed, ready f r correctio Plan check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Calcs. Plans picked up Construction Flood plain.plan Plans resubmitted I -- Mechanical Grading.plan 2nd Review, ready for correctioissue Electrical Subcontactor. List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval ' Plans resubmitted Grading IN HOUSE:- 7n° Review, ready for co rrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of per U issue �I O School Fees Total Permit Fees 511q� Vch wE � 06/06/2006 16:23 7143634747 VCA CODE GROUP PAGE 02 CITY SOF' LA QUI A PLAN CHECK CORRECTION LIST The Flying. Buttress June 6, 2.006 73661 Highway 111 Suite G Palm Desert, California 92260 Structural Ravlew Only PLAN CHECK NO.. 05-5350 (REVISION) APPROVED ADDRESS 52839 Via Savona OCCUPANCY R -3/U-1 SCOPE OF ORK NSFR 5627/1182 TYPE -OF -CONST.' V -N 1 PLAN CHECK FEE 4 Hours The submitted plans and specifications have been reviewed by the VCA CODE GROUP. In our professional opinion the plans are in substantial conformance with the building codes and regulations adopted by the .CITY OF LA QUINTA and the State of California Amendment. APPROVAL FOR A BUILDING PERMIT IS HEREBY RECOMMENDED SUBJECT TO OBTAINING APPROVALS/CLEARANCES FROM ALL APPLICABLE, CITY DEPARTMENTS, AGENCIES, AND ASSOCIATIONS. 1. Applicant to pay an additional plan check fee. of 4 hours for review of revised ,plans. Plans checked by: Hue Luu; PE VCA CODEGROUP 2200 W Orangewood. Ave, Ste 155 Orange, CA ,92868 (714) 363-4700 ext. 758 VCA File No.. LQ- 18.109 06/06/2006 16:23 7143634747 VCA CODE GROUP PAGE 04 08/06/2006 11:50 FAX 760 779 1317 The P13 -1n Buttress 2005 �' tt 9 .06/06/2006 16:23 7143634747 VCA CODE GROUP PAGE° 05 us�US/EUAe, 11:51- F41.760 7791317 T$e Flying Buttress 200B. 01W ftR mocK, (,ryP) SI - - . a r tai• 2X Sno M1WALL / f t SHEAR 7RANSF i 9T�TIM2 EXE 10d C47WONS AT 0 O.G, MMJ i 91MP50N• ADS cLip `} 2X NAILER WIT9i 1/2" !vwo AT Ito O.G. (rm) .i - A r 92n or TOP' AKO ;R BOTTOM FLAK ^ OCT, OP' TRU`,;9 ' x, W 12* 141E WITM 9/b" S lid, PLATE ' Nfel`I6EF� At`EAchf A7 1/4 P15. ID' -1" BOTTOM OP NAILER i Roo FRAMEINS AT STEEL BE 'm 4r� 06/06/2006 16:23• 7143634747 VCA CODE GROUP.- PAGE 08 udiva!zu01t 11:51 'FAX 760 779 1317 _ The Flying Buttress 0009 i /��% /� / `• o , Kim ti � �E .BEAM AT .SHEAR PANEL o l F,. , • �1 MN.o IOd CIOWON5 AT 6" o4. irYlr'J 2x NAILS WITW_ um" 91'f " 8, AT 92" D.G. TOP ANCA 5-1/Pi" X 15" dW ' tl1 A 12x90 WI'I"M 9/8" eirr. FLA1'M 0 O^ILOCATIONg At PLATE = ,OF BEAM1/4" 7 I r. NA 1 F, A�II" H. X 10".W. X3/8" WITH 2-5/4° PIAM, AUn Mss. QA STIML PLAT 6"X 6" X/8° . StOWT PLAM Q�1■ A^96 60lYor� OF WAILM g/0 SLB AT STEEL DEAM O 06/06/2006 "16:23 ,7143634747 -VCA CODE GROUP; PAGE 10 vvrvJ/4uU0 al:ae FAA 700 778 1317 Tlae Flying Buttress" X1011 p i } SIMPSCM MST46 . • �` 48-184 GCrMMOM ,Qd .-� 1.9E MIGROLLAM WITH 5-164 51wlER5) 1-8/4" X 11-1/4" AT 12" O.G. EAGN 91GE 1.9E MIGROLLAM . � � • 51MP'rO�K401�2- A (..noNN,E0T10N. AT GANTI LEVER f3EAM - I O - FP.-GTOI NAIL 104 c*mmONw AT 61' O.G. ('fYl?J i SIMP50N ASA CLIP', Tt AT 16" 04. ("J r 51MPSON HU26TF HAN6M 2X NAILER K* V2p, 9711* AT EACH TOP-0 AT 92" OZ. `TOP AND BOTTOM FLANSM i WT. OF TW95 IW 12xW ' WITH 5/9" STIPP. PL-ATES AT 1/4 M. BOTTOM OF Nr4gL�1Z "7 R00f= FKAM I NCS AT STEEL E3EAM I oa TITLE 24 REPORT Title 24 Report for: Drewes Residence Lots 21/22 - The Hideaway La Quinta,_CA �.•8�9 I�iA S AvoivA r Project, Designer: Report Prepared By: Joan D. 'Hacker Insu-form, Inc. • 41-921 Beacon Hill, Suite A Palm Desert; CA 92211 (760) 779-0657 LOF LA QUINTADING & J-pla:N4umberAPPR VEloOR CONSB - a- . The'EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy_ Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program, developed by EnergySoft, LLC - www.ehergysoft.com. EnergyPro 4.1 by EnergySoft Job Number: User Number: 205 Certificate Of Compliance: Residential Existing Floor Area: (Part 1 of 4) CF -1 R ntewps Res*r1PncP Project Title I 21/22 The HideawavLe Qllintq Slab on Grade Area: 5,627 ft2 6/8/2006 Date nts - Project Address �— Number of Dwelling Units: 1.00 Number of Stories: Building 9 Permit# Inco -form Inc (760) 779-0657 Documentation Author Telephone Plan Check/Date FnergyPrO Compli''Mce Method 15 Climate Zone Field Check/Date TDV Energy Use Standard Proposed Compliance (kBtu/sf-yr Design Design Margin Space Heating 1.06 2.33 -1.26 Space Cooling 53.10 51.12 1.98 Fans 7.96 7.63 0.33 Domestic Hot Water 4.56 5.46 -0.90 Pumps 0.00 .0.00 0.00 Totals 66.69 66.54 0.15 Percent better than Standard: 0.2% Building Type: [X—] Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: Area: 1,261 ft 2 Ratio: 22.4% BUILDING ZONE INFORMATION Zone Name ❑ Addition Existing + Add/Alt (E) 90 deg Natural Gas Avg. U: 0.57 Avg. SHGC: 0.41 Total Conditioned Floor Area: 5,627 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 5,627 ft2 Average Ceiling Height: 13.0 ft Number of Dwelling Units: 1.00 Number of Stories: 1 # of Floor Area Volume Units Zone Type IjVinq 7nno 569 7 OPAQUE SURFACES Type Wall Wall Wall Wall Wall Wall Wall Wall Rnof Insulation Act. Gains Condition Frame Area U -Fac. Cay. Cont. Azm. Tilt Wnnd 434 n o74 R_19 R_n n An gn Wood 36 n 074 R-19 R-0 0 135 90 Wood 390 n 074 R-19 R-0-0 180 90 Wood 24 n n74 R-19 R -n n 225 _g0 Wood 34 0.074 _R-19 R-0.0 270 90 Wood 124 0.074 _B_19 R-0.0 315 _gn Wood 647 n n74 R-19 R-0 0 _n g0 Wnod 12 n 074 R_19 R_0 0 45 gn Wood —1; 627 00,51 R_19 R-0 0 0 0 Y ®❑New IN ® ® ® ® ® ® ®❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ / N ❑New ❑New ❑ ❑New E:1 ❑ ❑ ENew ❑ ❑ ❑ ❑- ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Status New New New NPw Thermostat Vent Type Hgt. Area Setback— 2 —n/a JA IV Reference Location / Comments 09 -AS I ivin9 7nne 09 -AS Living lone 09 -AS I iving lone 09 -AS Living 7nne 09 -AS living Zone 09 -AS I ivin9 7nne MAS I iv6n9 7nne 09 -AS 1 ivin9 Zone 02 -AS I ivin9 7nne EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:3 of 13 1 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Drewes Residence Condition Status Location/ Comments a 4.632 6/8/2006 Project Title New Living Zone / Slab on Grade Concrete, Heavyweight Date 3.50 28 0_98 2 FENESTRATION SURFACES New Living Zone / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length True Cond. JA IV Reference Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type New Comments 1 Window Front (E) 200 -0_57 NI --1-0.38 COG _90_ 40_ New PPC, SOI ARRAN 60 (2) Clear I eying 7nne 2 Window Front (E) 20.0 0.570 NI -1 0_38 COG 90 90 New PPG SOLARBAN 60 (2) Clear Living Zone 3 Window Front (E) 31.5 0.570 NI -1 0_38 COG 90 90 New PPG SOLARBAN 60 (2) Clear Living Zone 4 Window Front (E) 25.0 0.570 NI -1 0_38 COG 90 90 New PPG SOLARBAN 60 (22) Clear Living Zone 5 Window Front (SE) 14.0 0.570 NI -1 0_38 COG 135 90 New PPG SOLARBAN 60 (2) Clear Living Zone 6 Window Left (S)_ 5.0 0.570 NI -10-38 COG 180 90 New PPG SOLARBAN 60 (2) Clear Living Zone Z Window Left (S) 27.0 0.570X11-1 0.38 COG 180 90 New PPG SOLARBAN 60 (2) Clear Living Zone 8 Window Left (S) 54.0 0.570 NI -1 0_38 COG 180 90 New PPG SOLARBAN 60 (2) Clear Living Zone 6 Window Left (S) 5.0 0.57 N1-1-0 3$ COG 180 90 New PPG SOLARBAN 60 (2) Clear Living Zone -m Window Left (~S) 15.0 0.57 NI -11 -0-W COG 180 90 New PPG SOLARBAN 60 (2) Clear Living Zone 11 Window Left (S) 24.0 0 57 N 10 38 COG 180 90 New PPG SOLARBAN 60 (2) Clear Living Zone 12 Window Left (SW) 26.3 0.570 NI -1 0_38 COG 225 90 New PPG SOLARBAN 60 (2) Clear Living Zone 13 Window Rear (W) 45.0 _1.57 NI-1-3$rQCa 70_ _9.Q New PPG SOLARBAN 60 (2) dear Living Zone 14 Window Rear on 20.0 0.570 NI -1 0_38 COG 270 90 New PPG SOLARBAN 60 (2) Clear Living Zone 15 Window Rear (W) 20.0 0.570 NI -1 0_38 COG 270 90 New PPG SOLARBAN 60 (2) Clear Living Zone 16 Window Rear (W) 26.3 0.570 NI -1 0_38 COG 270 90 New PPG SOLARBAN 60 (2) Clear Living Zone 17 Window Rear (W) 22.5 0.570 NI -1 0_38 rc)G 270 90 New PPG SOLARBAN 60 (2) Clear Living Zone 18 Window Rear (W) 225.0 0.570 NI -1 0_38 COG 270 90 New PPG SOLARBAN 60 (2) Clear Living Zone J -a Window Rear (W) 48 0 X79 NI -1 -0-W BOG 970 90 New PPG SOLARBAN 60 (2) Clear Living Zone 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 9.0 3.6 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 5.0 2.5 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 7.0 2.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 2.0 2.5 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 9.0 3.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 9.0 3.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 2.0 2.5 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 2.5 2.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 8.0 3.0 12.0 0.1 12.0 12.0 12 Bug Screen 0.76 7.5 3.5 8.0 0.1 8.0 8.0 13 Bug Screen 0.76 4.5 5.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 1.8 3.0 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 1.8 3.0 2.0 0.1 2.0 2.0 16 Bug Screen 0.76 7.5 3.5 . 8.0 0.1 8.0 8.0 17 Bug Screen 0.76 9.0 2.5 12.0 0.1 12.0 12.0 18 Bug Screen 0.76 9.0 20.0 8.0 0.1 8.0 8.0 19 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 8.0 THERMAL MASS FOR HIGH MASS DESIGN Type Area Thick. Heat Inside (so (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments Concrete, Heavyweight 4.632 3.50 28 0_98 0 26-A1 New Living Zone / Slab on Grade Concrete, Heavyweight 995 3.50 28 0_98 2 26-A1 New Living Zone / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 18 None No Insulation 26-A1 New Living Zone Slab Perimeter 18 None No Insulation 26-A1 New Living Zone Run Initiation Time: 06/08/06 10:39:51 Run Code: 1149788391 EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:4 of 13 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Drewes Residence 6/8/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Aim. Tilt Stat. Glazing Type Comments 7Q Window Rear (W) 54 0 0 570 NI -1 _0.38 Mr, _220_ 9D- New PPG SOLARBAN gn (2) Clear I iving lone 21 Window Rear (W) 27.0 0.570 NI -1 0_38 COG 270 90 New PPG SOLARBAN 60 (22) Clear Living Zone 22 Window Rear (W) 48.0 0.570 NI -1 0_38 COG 270 90 New PPG SOLARBAN 60 (2) Clear Living Zone 23 Window Rear (W) 22.5 0.570 NI -1 0_38 COG 270 90 New PPG SOLARBAN 60 (22) Clear Living Zone 24 Window Rear (W) 54.0 0.570 NI -1 0_38 COG 270 • 90 New PPG SOLARBAN 60 (2) Clear Living Zone 25 Window Rear (W) 54.00.57NI.10 38 COG 270 90 New PPG SOLARBAN 60 (2) Clear Living Zone 2Si Window Rear (NW) 26.3 0.57NI-1 JQM BOG X15 90 New PPG SOLARBAN 60 (2) Clear Living Zone 27 Window Right (N) 26.3 0.570 NI -1 0.38 COG 0 90 New PPG SOLARBAN 60 (2) Clear Living Zone 2$ Window Right (N) 12.5 3 57 NI -1 -Q -W C9Sz 90 New PPG SOLARBAN 60 (2) Clear Living Zone 2;3 Window Right (N) 21.0 0-57 NI -1 COG 0 90 New EPG SOLARBAN 60 (2) Clear Living Zone 2Q Window Right (N) 12.0 0_570 NO0 38 COG 0 90 New PPG SOLARBAN 60 (2) Clear Living Zone 31 Window Right (N) 39.0 0.570 NI -1 0_38 COG 0 90 New PPG SOLARBAN 60 (2) Clear Living Zone Bug Window Right (N) 5.0 O,57 NL -1 -QM TQC, 0 -0_ New PPG SOLARBAN 60 (2) Clear Living Zone 33 Window Right (N) 5.0 0.570 NI -1 0_38 COG 0 90 New PPG SOLARBAN 60 (2) Clear Living Zone 34 Window Right (N) 10.0 0.570 NI -1 0_38 COG 0 90 New PPG SOLARBAN 60 (2) Clear Living Zone 35 Window Right (N) 22.5 0.570 NI -1 0_38 COG 0 90 New PPG SOLARBAN 60 (2) Clear Living Zone 36 Window Right (NE) 26.3 0.570 NI -1 0_38 ror. 45 90 New PPG SOLARBAN 60 (2) Clear Living Zone 37 Window Right (N E) 54.0 0.570 NI -1 0_38 COG 45 90 New PPG SOLARBAN 60 (2) Clear Living Zone �U Window Right (NE) 54.0 0.579_NL-1-Q-W BOG 45 90 New PEG SOLARBAN 60 (2) Clear Living Zone 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 9.0 3.0 8.0 0.1 8.0 8.0 21 Buq Screen 0.76 9.0 1.5 30.0 0.1 30.0 30.0 22 Bug Screen 0.76 8.0 3.0 30.0 0.1 30.0 30.0 23 Bug Screen 0.76 9.0 2.5 12.0 0.1 13.0 12-0 24 Bug Screen 0.76 9.0 3.0 12.0 0.1 12.0 12.0 25 Bug Screen 0.76 9.0 3.0 12.0 0.1 13.0 12.0 26 Bug Screen 0.76 7.5 3.5 8.0 0.1 8.0 8.0 27 Bug Screen 0.76 7.5 3.5 8.0 0.1 8.0 8.0 28 Bug Screen 0.76 2.5 2.5 2.0 0.1 2.0 2.0 29 Bug Screen 0.76 7.0 3.0 2.0 0.1 2.0 2.0 30 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 31 Bug Screen 0.76 6.5 6.0 2.0 0.1 2.0 2.0 32 Bug Screen 0.76 2.5 2.0 2.0 0.1 2.0 2.0 33 Bug Screen 0.76 2.5 2.0 2.0 0.1 2.0 2.0 34 Bug Screen 0.76 2.5 2.0 2.0 0.1 2.0 2.0 35 Bug Screen 0.76 4.5 5.0 2.0 0.1 2.0 2.0 36 Bug Screen 0.76 7.5 3.5 8.0 0.1 8.0 8.0 37 Bug Screen 0.76 9.0 3.0 2.0 0.1 2.0 2.0 38 Bug Screen 0.76 9.0 3.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation ;Hath R -Val. Location Condition JA IV Reference Status Location/ Comments Run Initiation Time: 06/08/06 10:39:51 Run Code: 1149788391 EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:5 of 13 Certificate Of Compliance: Residential (Part 2 -of 4) CF -1 R Drewes Residence 6/8/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 3R Window Right (NEE) 140 057 NI -1-3$ COG 4_ _90_ New 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. Hgt. Dist. Len. Hgt. 39 Buq Screen 0.76 7.0 2.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/' Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 06/08/06 10:39:51 Run Code: 1149788391 EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:6 of 13 c f A O SMITH PGCG-50-246 Small Gas No Pipe Insulation 2. 40,000 50 New 0.62 n/a n/a Multi -Family Central Water Heating Details . Hot Water Pump' 'Hot Water Piping Length'(ft) Add 1/2" , Control #, HP Type, In Plenum Outside Buried Insulation 1 For small.gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. ` For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. . For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. n0eeeovO , COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts I and 6 of the California Code of Regulations, and the administrative regulations to implement them. 'This certificate has been signed by the individual with overall design responsibility.. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an -approved HERS rater. Designer of Owner (per Business & Professions Code) Documentation Author Name: Name: Joan D. Hacker 'Title/Firm: Title/Firm: Insu-form, Inc. ' -Address: Address: 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 Telephone: Telephone: (760) 779-0657 Lic. #: (signature) (date) (sig ture) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature/stamp) (date) Run lnotjaton Tmee 06108106 MUM Run Code@ 11149786911 Ener Pro 4.1 by Ener Soft User Number: 2655 Job Number: Page: 7 of 13 .certificateV Compliance: Residential ,' (Part 3 of 4) CF -1 R ' Drewes Residence 6/8/2006 Project Title Date HVAC SYSTEMS • - Heating Minimum Cooling , ndition Thermostat Minimum Co Location Type Eff Type • Eff, -_ Status ° :. Type Living Zone Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER New Setback HVAC DISTRIBUTION Duct . Duct Condition Ducts ' Location - Heating Cooling Location R -Value Status Tested? Living Zone ` Ducted Ducted Attic 6.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. ` WATER HEATING SYSTEMS Rateds Tank Energy : Standbys Tank insult Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type• Distribution Syst. (Btu/hr) (gal) Status or RE s (%) Ext.. A O SMITH PGCG-50-246 Small Gas No Pipe Insulation 2. 40,000 50 New 0.62 n/a n/a Multi -Family Central Water Heating Details . Hot Water Pump' 'Hot Water Piping Length'(ft) Add 1/2" , Control #, HP Type, In Plenum Outside Buried Insulation 1 For small.gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. ` For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. . For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. n0eeeovO , COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts I and 6 of the California Code of Regulations, and the administrative regulations to implement them. 'This certificate has been signed by the individual with overall design responsibility.. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an -approved HERS rater. Designer of Owner (per Business & Professions Code) Documentation Author Name: Name: Joan D. Hacker 'Title/Firm: Title/Firm: Insu-form, Inc. ' -Address: Address: 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 Telephone: Telephone: (760) 779-0657 Lic. #: (signature) (date) (sig ture) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature/stamp) (date) Run lnotjaton Tmee 06108106 MUM Run Code@ 11149786911 Ener Pro 4.1 by Ener Soft User Number: 2655 Job Number: Page: 7 of 13 Certificate Of Compliance Residential (Part 4 of 4) CF -1 R Drewes Residence 6/8/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement aqency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the rdequacy of the special justification and documentation submitted. Plan I Field The Roof "R-38 Roof (R.38.2x14.16)" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. HIGH MASS Design - Verify Thermal Mass: 4632 sgft Exposed Slab Floor, 3.50" thick at Living HIGH MASS Design - Verifv Thermal Mass: 995 sgft Covered Slab Floor, 3.50" thick at Living HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using CEC approved testing and/or verification methodsand must be reported on the CF -4R Plan Field installation certificate. The HVAC System "Living Zone" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF - 4R. The HVAC System "Living Zone" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve: This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. Run Initiation e: 06/08/06 0:39.51 Run Code 149 8839 EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:8 of 13 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must'contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (*) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑x El § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ' ❑x ❑ apply to exterior mass walls). ❑ ❑ ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 1. Masonry and factory -built fireplaces have: 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(0: Air retarding wrap installed to comply wits 151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. 1-1 entirely in conditioned space. § 118: insulation specified or installed meets insulation installation quality standards. Indicate type and ❑ ❑x El include CF -6R Form: ❑ EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ 0 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain infiltration ❑ ❑ Coefficient (SHGC), and certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑x ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑x ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑x ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑x ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with ❑ ❑ ❑ insulation having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source ❑ ❑x ❑ and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A: ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ 1-1 entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:9 of 13 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (7 below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and 2. System is installed with: support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ reductions in the cross-sectional area of the ducts. ❑ ❑ El § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are ❑ ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ luminaire has factory installed HID ballast. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ retardant and provides shielding from solar radiation that can cause degradation of the material. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article ❑ -❑ ❑ 7. Flexible ducts cannot have porous inner cores. • Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 114: Pool and Spa Heating. Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ El § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑ ❑ controlled by an occupant sensor that complies with Section i 19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑' Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page: 10 of 13 Residential Kitchen Lighting Worksheet WS -5R Drewes Residence - 6/8/2006 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be.in luminaires that are high efficacy luminaires as defined in Table 150-0. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts • Other Watts (1) 40w Fluorescent Twin Elec Yes X No 36.0 x 10 = 360 or -- Yes No X = or Yes No x = or Yes No X _ or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No X = or `. Yes No x = or Yes No x = or Yes No x = or Yes No x = or. Yes No x = or Yes. No x = or Yes No x- or Yes No x _ or. Yes No X - or YesNo X = or. Yes No -x ,= .or Total A. a • 360 B: 0 COMPLIES IF A>_B YES® NO El EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:11 of 13 IHVA'C SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Drewes Residence 6/8/2006 SYSTEM NAME FLOOR AREA Living Zone 5,627 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 4 Heating System Output per System 56,000 Total Output (Btuh) 224,000 Output (Btuh/sqft) 39.8 Cooling System Output per System 35,000 Total Output (Btuh) 140,000 Total Output (Tons) 11.7 Total Output (Btuh/sqft) 24.9 Total Output (sgft/Ton) 482.3 Air System CFM per System 1,300 Airflow (cfm) 5,200 Airflow (cfm/sqft) 0.92 Airflow (cfm/Ton) 445.7 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent 1,1 CFM I Sensible 5,124 72,435 5,571 1,723 70,490 0 cfm 6,577 5,614 0 0 0 0 0 0 0 0 0 6,577 5,614 85,588 5 571 81 718 BDP CO. 563AN036-A 86,658 44,247 224,000 Total Adjusted System Output 86,658 44,247 224,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am HLA I ING SYS I LM r5YL;HKUMt I Klts Airstream Temperatures at Time of Heating Peak 26.0°F 69.0°F 69.0°F 109.20F Supply Air Ducts Outside Air 0 cfm 108 )Or All Supply Fan Heating Coil 5200 cfm ROOMS 70.0 OF 69.0 °F Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.4°F 79.2/67.9°F 79.2/67.8°F M 63.6/62.6°F Supply AirX. Ducts Outside Air 0 cfm Supply Fan Cooling Coil 64.8 / 63.0 OF 5200 cfm ROOMS 58.7% R.H. 78.0/67.5°F 79.2/67.9°F Return Air Ducts EnergvPro 4.1 by EnergySoft User Number: 2655 Job Number: Page: 12 of 13 FRbdM LOAD SUMMARY PAGE TOTAL 1 5,124 72,435 5,57t1' 1,723 70,490 TOTAL 1 5,124 72,435 51571 ,1,723 70,490 EnergyPro By EnergySofl User Number: User Job Number: Page:13 of 13