Loading...
BRES2016-0175' VOICE (760) 777-7125 78-8- 495 CALLE TAMPICO T �a^"""'�FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 DESIGN.& DEVELOPMENT DEPARTMENT 'INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 8/26/2016 Application Number:. BRES2016-0175 Lr_�� -LI Oner: Property Address: 52839 VIA SAVONA JO HN DREWES APN: 777370011• AUG ^' n r 5051 KEANE DR Application Description: DREWES / CONVERT PATIO TO LIVING SPA � E f� 20�.� )CARMICHAEL, CA 92253 Property Zoning: CI'll'Gt C ��UIPI'iA Application Valuation: $35,000.00 COd9M1Ui1iT(DEVELCPi'OENTDEPARTillErdT Applicant: Contractor: MONARCH HOMES DESERT DIVISION INC DBA DA MONARCH HOMES DESERT DIVISION INC DB_ A DA 49-950 JEFFERSON ST #130-134 49-950 JEFFERSON ST #130-134 INDIO, CA 92201 INDIO, CA -b2201 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Cla : B License NNoo..:-457228 `Date: Cor ntra'ctor. OWNER -BUILD DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that.requires a permit to construct, alter, improve, demolish, or repair any structure,.prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( 11, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements. are not intended or offered for sale. If, however; the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build, or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to.construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction' lending agency for the performance of,the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address:' (760)413-8863 LIC. No.: 457228 4 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance; as. required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 9045509 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' com ensation provisions of Section 3 0 of the Labor Code, I shall forthwith . comply with t ose provisions. Dat rAppli'cgnt: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and.void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and stat laws relating to building construction, and hereby authorize representatives oAthisci topon the above-m�entio ed p op rty for inspection purposes. Date) Signature-'(Ap� pl Age Application Number: BRES2016-0175 Property Address:' 52839 VIA SAVONA APN: 777370011 Application Description: DREWES / CONVERT PATIO TO LIVING SPACE . Property Zoning: Application Valuation: $35,000.00 Applicant: MONARCH HOMES DESERT DIVISION INC DBA DA 49-950 JEFFERSON ST #130-134 INDIO, CA 92201 Date: 8/26/2016 Owner: JOHN DREWES 5051 KEANE DR CARMICHAEL, CA 92253 i Contractor: MONARCH HOMES DESERT DIVISION INC DBA DA 49-950 JEFFERSON ST #130-134 INDIO, CA 92201 (760)413-8863 Llc. No.: 457228 -----------------------=--------------------------------------------------------------------- Detail: ADDITION 255 SQ FT ON EXISTING OVERHANG OF CONVENTIONAL LIGHT FRAME CONSTRUCTION PER CRC CODE 2013 FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $62.36 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF PC 101-0000-42600 0 $171.14 Total Paid for ADDITION: $371.73 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE -YES ADMINISTRATIVE STAFF 101-0000-42600 0.25 $10.00 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - YES ADMINISTRATIVE STAFF 101-0000-42600 0.25 $10.00 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - YES STRUCTURAL PLAN REVIEW ENGINEER 1010000-42600 2 $190.00 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - YES STRUCTURAL PLAN REVIEW ENGINEER 101-0000-42600 0.5 $47.50 Total Paid for BLDG CITY STAFF - PER HOUR: $257.50 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $2.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,OOOSF 101-0000-42403 0 $145.03 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,OOOSF, PC 101-0000-42600 0 $47.86 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 DESCRIPTION ACCOUNT . QTY AMOUNT APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.09 DESCRIPTION ACCOUNT QTY AMOUNT APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 0 $4.83 Total Paid for MECHANICAL: $16.92 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $4.55 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $4.55 TOTALS: $845.59 Bin # •� City of La Quin to Building U Safety Division 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # 2L (D'D� Project Address: Z Sion Owner's Name: Hot. t. -ort S A. P. Number: Address: �2 %'3,1Lh l tk" Legal Description: City, ST, Zip: �� 2Z Contractor: S K Tele h n pone: P Address: Project Description: City, ST, Zip: . ' d Ld 9 2-!zqfv Telephone: D 3 �r Ldv State Lic. # : �i� City Lie. #; A& rl Arch., Engr., Designer: 01 r d Of—e— 11W r,do� r Address: 0 �3 City, ST, Zip: U w q? Telephone: � State Lic. # . ...... Cn tru tt � n type: e• OccuPan cY Project nPa (circle one): New d' Alter Repairair Demo Name of Contact Person: 3>A Sq. Ft.: OZ45 # Stries: #Units: Telephone # of Contact Person: to P �5 3 �• ; Estimated Value of Project: �d0 f APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cales. Called Contact Person Plan Check Balance Title 24 Cales. Plans picked up. Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2nd Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O:A. Approval Plans resubmitted Grading IN HOUSE:- '"! Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, Total Permit Fees Coac.helAla Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 Project Name: Johns Dream Owner's Name: This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Address: 52-839 Via Savona, La Quinta, CA 92253 Project Description: Patio Conversion to Living Space (Room Addition) APN: 777-370-011 Tract #: Type of Development: Residential XX Commercial Date: August 11, 2016 Phone No. Lot #'s: Industrial Total Square Feet of Building Area: 225 sq. ft. Certification of Applicant/Owners: The person signing certifies that/he wformation is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sfgi on ehalf o e owner/developer. Dated: Signature: *************** *************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code 65995 225 EXEMPT 0.00 Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Leticia Torres, Facilities Analyst Note: Pursuant to AB 181 any room additions or enclosures of 500 Ms.f. or_less.are_exempt_from-developer_feed Any mobile homes being relocated or replaced within the same school district's jurisdiction are exempt from developer fees. NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES ANPISTAMEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that istrict provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in rega d to such Fee validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 6 of e G rnde.Dancy. tionall the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior ti nc of eerttrVief yAs in the latter, the 90 days starts on the date hereof. ThisCertificateof Compliance is valid for thirty (30) days from the ate of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. 41V:c/mydocs/devfecs/certificate of compliance IAuapc1, T-2:0116 CITY OF LA QUINTA COMMUNITY DEVELOPMENT 11/2010 June 29, 2016 Mr. and Mrs. John Drewes 5051 Keane Drive Sacramento, CA 95608 Re: Lot 21/22C at 52839 Via Savona Architectural Modifications Dear Mr. and Mrs. Drewes, This letter shall serve as notification that the Hideaway Design Review Committee (DRC) reviewed your architectural modifications at the June 21, 2016 meeting. The request to remove the arch at the Master Bedroom and expand the room, without changing the roof line, was approved subject to any new windows/doors being recessed appropriately, per the guidelines. Please contact Brook Marshall at 760-219-8057 or by email at DRCFacilitatorna gmail.com with any questions regarding this review or when the project is complete so a final construction review can be scheduled. Sincerely, THE HIDEA WA Y DESIGN REVIEW COMMITTEE .0 Title: cc: Monarch Homes DRC File Date: 11ECEI\ ED AUG 1 1 2016 ' A Pursuant to Cal. Civil Code, any rejection by the DRC may be appealed to the Board of Directors for the Association. If you wish to pursue an appeal, please contact the Association's property manager directly. Section Five Development Regulations 5.4 Development Regulations " .5.4.1 Ae der tial De elopri ent_Star dards.. TABLES Resi entiai Devern lonent Sta ciarids: :' p 1 .✓ �,{ i=5 P � ; °'CS *+.Id �"k ;�#���t,�'�� &uu�y 2,^�t+�Zx°+��L W't^rr irk _ �h��a 4'��ac`�,_ Min. Lot Size 10,000 s.f." 7,500 s.f. Min. Lot Frontage 85' 40' Max. Structure Height (Excluding Basement) 2 28' 28' Max. No. of Stories 2' 2' Min. Front Yard Setback/Non-Garage (from back of curb) 25' 15' Min. Front Entry Garage Setback (from back of curb) 3 30' 20' Min. Side Entry Garage Setback :25' " 5' Min. Interior Side Yard 5' 3' Min. Corner Side Yard 20' 10' Min. Rear Yard Setback 25 10' Min. Building Separation N/A N/A Min. Private Open Space Dimension. N/A N/A Max. Lot Coverage 50% 80% Min. Livable. Area (Exdudmg Garage) s 3 500 s,f _ 2,600 s.f. '4:! CUSTOM/SINGLE FAMILY DETACHED VILLAS ,. For main residence, per"Development code. In For main residence, per Development code. In addition, one guest parking space shall be provided on. addition, one guest parking space shall be provided for each lot. Guest parking must not impede full access to every two units. Guest parking must not impede full the• garage`,and driveway to the street. :.access.to...the.ga.rage.:and driveway to..the street: _.. ��` n TYPE . . Decorative roof projections such as chimneys, roof vents, finials, 8' projection allowed spires, and similar architectural features not containing usable space. • Roof overhangs, chimneys, media niches, awnings, and 6' projection allowed on south and west canopies. • Cantilevered seating windows or ledges, which are located a 2',projection allowed minimum of 1' above the floor and do not increase a building's usable floor area. • Balconies, exterior stairways, and elevated uncovered decks, '4' projection allowed" into front or rear which do not increase a buildirig.'s usable floorspace. setback prolectign allowed" into side setback FOOTNOTES n 1. Min. lot frontage on curves, cul-de-sacs, and knuckles shall be 25'. Min. lot frontage for flag lots shall be 15' 2. Any portion of a basement above any finish grade is excluded from calculation of building height. Buildings within 150 feet of a General Plan Image Corridor (Avenue 52, Avenue 54, and Madison Street) are limited to 22'. within the 150400t zone. 3. Roll -up type garage doors are required. 4. For interior setbacks, if the building is over.17' in height, the setback is 5' plus 1' for every foot over 17' in height or fraction thereof, to a maximum required setback of 10'. The additional setback may be provided : entirely.,at grade level or a combination of at grade and airspace above the 17' building. 5." Developer reserves the right to control unit type through Development Regulations and through application to the City for a Conditional Use Permit for special product types, including attached or zero lot line residences... "The Madison Club" Specific Plan. 99-035 mendrnent #1 February 2005 5-2 r Plan submittal Job Site Building Permit Number. Project Description: homeowner improvement Exempt: O (Maierlab may cornbin hazardous wastes and aro not subject to recycling Provisions) Construction Debris Management Plan Ownees Name Number, Sheet, or PO Box City. stab. Postel Code Owners Phone Number Owner's E -Mail Address Project Manageft Project Manager's Phone N Project Manegers E-mell A Builder / Corntn Number, Street or PO city, stab, Postal C iia 8!12/2016 52-839 Via Savona Mr. and Mrs. Drawers 52-839 Via Savona La Quints, CA. 92253 Dave Jacobsen 760-413-8883 Monarch Homes -Desert Division 49950 Jefferson Street Indio, CA. 92201 255 square feet Date of City Approval 013112.11(y To Be Discarded: Product Trash Asphalt Brid Block Cardboard Commingled Concrete Drywall Donated / Reuse' -Describe Items I ls: RecYcle Trash 1.5 1 1.3 Not recyclable Recyclable Product Masonry (broken) Plaster Scrap Metal Tile (floor) Tile (roof) Wood Landscape Debris Tons Projected Diversion: t35.Z09L Recyclable 1 understand It is the property ownefs respors"ftY m submit wpbs of weight tickets or recetpts to the District Environmental Coordirrator es time hauls occur. I hereby cw* that completton, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 509E of the jobsite wast Is diverted from landfilling. The remaining material will be recycled or reused. I will dtvart, for recycling or reuse, remaining mamr" generate from the That day of the project through the compleilon of the project in accordance with this plan. This DMP Is issued in the now of the property owner(s) and shall remain #m* property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued In the name of the property owner(s) and the owner retina legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept Informed of the diversion progress through bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer Owner / Developer I Project Manager I superintendent Dat To: City of La Quinta Today's Date: 78-495 Calle Tampico City Due Date: La Quinta, CA 92253 Project Address: Attn: Ramses Sevilla We are forwarding: Includes: # Of Copies: Submittal: ❑ By Messenger Descriptions: 8-24-16 8-25-16 52-839 Via Savona Plan Check #: BRES2016-0175 ❑ 1st ❑ 4th ❑ 2nd ❑ 55th Q 3'd ❑ Other: ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: # Of Descriptions: Copies: ❑ Structural Plans ❑ ❑ Structural Calculations ❑ ❑ Truss Calcs ❑ ❑ Soils Report - Update ❑ Structural P/C Responses 1 / Comments O 1 Redlined Structural Plans ❑ Redlined Structural Calcs ❑ ❑ Redlined Truss Calcs ❑ ❑ Redlined Soils Reports ❑ Comments: Structural content iS ar)grovable. Transit Per Diem= Admin Time = .25 HR Structural Engineer/Principal Review Time = HR Plan Review Engineer Time = 0.5 HR This Material Sent for: ❑ Your Files ❑ Your Review ❑ Checking Other: ❑ By: Joe Venuti Office: ❑✓ (760) 772-5107 Other: ❑ Revised Struct. Plans Revised Struct. Calcs Revised Truss Calcs Revised Soils Report 1 Approved Structural Plans 1 Approved Structural Calcs . Approved Truss Calcs Approved Soils Report Other: ❑✓ Per Your Request ❑ Approval ❑ At the request of: to 1-,AQ1rn\ Iain # Permit u 11 dPi'ojectAddress: 2 Qty of La Quinta 8uildina 8t Safety Division 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-701,2 Building Permit Application and Tracking Sheet q Owner's Name: A. P. Number: ,.-.A Address: Legal Description: '''e-ity, ST, Zip: — r:ontract o i Tele P hone: `. Address: e , P ct Descri ti n: City` ST, Zip: `/' 0 G of 2�' 'l . �/i slv✓\ ✓� C ele ho ne: T P G � State Lic. # :Ii CLica#.:•• t�A Arch., Engr., Designer: 6� Address: City, ST, Zip: Telephone: ne: aneY Occupancy: :C n tructi n TYPe: P Lie. # . n Alter Repair. r Demo ProJ•ecttyPe� cit le o ne • New A dd !r.*ame of Contact Person: ( 2� Sq. Ft.: # Stories: # Units: �1-elephone # of Contact Person: stimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cafes. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person , Plan Check Balance. Title 24 Calcs. Plans picked up tb Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for corrections/issue Electrical SubeontactorList Called Contac(Person Plumbing Grant Decd Plans picked up S.M.I. II.O.A. Approval Plans resubmitted Grading IN HOUSE:- '" Rcyiew, ready for corrections/issuc Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks_ Appr Date of permit issue School Fees. Total Permit Fees BUILDING ENERGY ANALYSIS REPORT I PROJECT:I Drewes Residen 52-839 Via Savo La Quinta, CA Project Design Revise Reylsep espoleor S CIN OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION Report Prepared by: L.:... Joan D. Hacker Insu-form, Inc. 72875 Fred Waring Drive, Suite C Palm Desert, Ca 92260 760-345-1352 Job Number: Date: 11/30/2016 7F () AGF CoP r •. The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnemvPro 6. by EnemvSoR User Number. 2655 ID: P. V, viluo AJ 90 Yflo :r9':';O Yr3-:IAB 3 rO*OlaJIUU 03VOnqqA I TABLE OF CONTENTS I a Cover Page Table of Contents Form CF -1 R -PRF -01-E Certificate of Compliance Form RMS -1 Residential Measures Summary Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary EnergyPro 6. by EnergySoft Job Number. ID: User Number: 2655 1 2 3 13 14 18 e CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Daterrime: 12:38, Wed, Nov 30, 2016 Calculation Description: Title 24 Analysis Input File Name: Drewes Existing Addition.ribdx CF1 R -PRF -01' Page 1 of 10 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name Single Fam Detached 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location 52-839 Via Savona Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 07 Compliance Manager Version BEMCmpMgr 2013-4b (433) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.8 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 5882 15 Number of Zones 2 16 Slab Area (ft) 5882 17 Number of Stories 1 18 Addition Cond. Floor Area 255 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 255 21 Glazing Percentage (%) 22.9.% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building incorporates one or more Special Features shown below Registration Number: Registration Datefl-ime: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08162016-433 Report Generated at: 2016-11-30 12:39:47 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 7.18 7.03 0.15 2.1% Space Cooling 213.61 213.47 0.14 0.1% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 5.48 5.48 0.00 0.0% Photovoltaic Offset -- 0.00 0.00 — Compliance Energy Total 226.27 225.98 0.29 0.1% Registration Number: Registration Datefl-ime: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-08162016-433 Report Generated at: 2016-11-30 12:39:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Daterrime: 12:38, Wed, Nov 30, 2016 Calculation Description: Title 24 Analysis Input File Name: Drewes Existing Addition.ribdx REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. 7.w— indow overhangs and/or fins HERS FEATURE SUMMARY CFI R -PRF -01 - Page 2 of 10 The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: —None— Cooling System Verifications: — None — HVAC Distribution System Verifications: — None — Domestic Hot Water System Verifications: -- None — ENERGY DESIGN RATING This is the sum of the annual TOV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 262.01 261.72 0.29 0.1% . includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Single Fam Detached 5882 1 4 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Existing Living Conditioned Existing Livingl 5627 9 DHW Sys 1 Sifting Room Conditioned Existing Living/ 255 9 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08162016-433 Report Generated at: 2016-11-30 12:39:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 12:38, Wed, Nov 30, 2016 Calculation Description: Title 24 Analysis Input File Name: Drewes Existing Addition.ribdx CF1 R -PRF -01 Page 3 of 10 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) Status Verified Existing Condition Front Wall Existing Living Default Walt 1978 to 1991 180 Left 800 99.008 90 Existing No Left Wall Existing Living Default Wall 1978 to 1991 270 Back 1200 130 90 Existing No Rear Wall Existing Living Default Wall 1978 to 1991 0 Right 900 621.307 90 Existing No Right Wall Existing Living Default Wall 1978 to 1991 90 Front 1200 153.311 90 Existing No Front 2 Existing Living Default Wall 1978 to 1991 135 45 300 14.004 90 Existing No Left Wall 2 Existing Living Default Wall 1978 to 1991 225 135 120 26.3 90 Existing No Rear Wall 2 Existing Living Default Wall 1978 to 1991 315 225 120 26.296 90 Existing No Right Wall 2 Existing Living Default Wall 1978 to 1991 45 315 148.4 148.3 90 Existing No Roof Existing Living Default Roof 1978 to Pres 5132 Existing No Front Wall 2 Sitting Room R-19 Wall 90 Front 200 0 90 New N/A Left Wall 3 Sitting Room R-19 Wall 180 Left 600 20 90 New N/A Back Wall Sitting Room R-19 Wall 270 Back 620 108 90 New N/A Right Wall 3 Sitting Room R-19 Wall 0 Right 780 0 90 New N/A Roof 2 Sitting Room R-38 Roof Attic 255 New N/A ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Existing Living Attic RoofExisting Living Ventilated 0 0.1 0.85 No No Existing No Attic Sitting Room Attic RoofSitting Room Ventilated 0 0.1 0.85 No No New No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08162016-433 Report Generated at: 2016-11-30 12:39:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 12:38, Wed, Nov 30, 2016 Calculation Description: Title 24 Analysis Input File Name: Drewes Existing Addition.ribdx CF1R-PRF-01• Page 4 of 10 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (ftz) U -factor SHGC Exterior Shading Status Verified Existing Condition Window Front Wall (Left -180) 3.0 8.0 0.938 22.5 0.71 0.73 Insect Screen (default) Existing No Window 2 Front Wall (Left -180) 4.0 5.0 1 20.0 0.71 0.73 Insect Screen (default) Existing No Window 3 Front Wall (Left -180) 2.0 2.0 7.875 31.5 0.71 0.73 Insect Screen (default) Existing No Window 4 Front Wall (Left -180) 6.0 2.0 2.083 25.0 0.71 0.73 Insect Screen (default) Existing No Window 5 Left Wall (Back -270) 5.0 1.0 1 5.0 0.71 0.73 Insect Screen (default) Existing No Window 6 Left Wall (Back -270) 4.0 6.0 1.125 27.0 0.71 0.73 Insect Screen (default) Existing No Window 7 Left Wall (Back -270) 6.0 9.0 1 54.0 0.71 0.73 Insect Screen (default) Existing No Window 8 Left Wall (Back -270) 5.0 1.0 1 5.0 0.71 0.73 Insect Screen (default) Existing No Window 9 Left Wall (Back -270) 5.0 3.0 1 15.0 0.71 0.73 Insect Screen (default) Existing No Window 10 Left Wall (Back -270) 5.0 6.0 0.8 24.0 0.71 0.73 Insect Screen (default) Existing No Window 11 Rear Wall (Right -0) 9.0 4.0 1.25 45.0 0.71 0.73 Insect Screen (default) Existing No Window 12 Rear Wall (Right -0) 5.0 4.0 1 20.0 0.71 0.73 Insect Screen (default) Existing No Window 13 Rear Wall (Right -0) 4.0 5.0 1 20.0 0.71 0.73 Insect Screen (default) Existing No Window 14 Rear Wall (Right -0) 5.0 3.6 1.461 26.3 0.71 0.73 Insect Screen (default) Existing No Window 15 Rear Wall (Right -0) 5.0 4.3 1.047 22.5 0.71 0.73 Insect Screen (default) Existing No Window 16 Rear Wall (Right -0) 20.0 8.0 1.125 180.0 0.71 0.73 Insect Screen (default) Existing No Window 17 Rear Wall (Right -0) 6.0 8.0 1 48.0 0.71 0.73 Insect Screen (default) Existing No Window 18 Rear Wall (Right -0) 9.0 8.0 0.75 54.0 0.71 0.73 Insect Screen (default) Existing No Window 19 Rear Wall (Right -0) 4.0 8.0 0.844 27.0 0.71 0.73 Insect Screen (default) Existing No Window 20 Rear Wall (Right -0) 6.0 8.0 1 48.0 0.71 0.73 Insect Screen (default) Existing No Window 21 Rear Wall (Right -0) 5.0 4.2 1.071 22.5 0.71 0.73 Insect Screen (default) Existing No Window 22 Rear Wall (Right -0) 5.0 9.0 1.2 54.0 0.71 0.73 Insect Screen (default) Existing No Window 23 Rear Wall (Right -0) 9.0 8.0 0.75 54.0 0.71 0.73 Insect Screen (default) Existing No Window 24 Right Wall (Front -90) 8.0 8.0 0.411 26.3 0.71 0.73 Insect Screen (default) Existing No Window 25 Right Wall (Front -90) 4.0 3.5 0.893 12.5 0.71 0.73 Insect Screen (default) Existing No Window 26 Right Wall (Front -90) 7.0 3.0 1 21.0 0.71 0.73 Insect Screen (default) Existing No Window 27 Right Wall (Front -90) 5.0 3.5 0.686 12.0 0.71 0.73 Insect Screen (default) Existing No Window 28 Right Wall (Front -90) 5.0 5.0 1.56 39.0 0.71 0.73 Insect Screen (default) Existing No Window 29 Right Wall (Front -90) 5.0 1.0 1 5.0 0.71 0.73 Insect Screen (default) Existing No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08162016-433 Report Generated at: 2016-11-30 12:39:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 12:38, Wed, Nov 30, 2016 Calculation Description: Title 24 Analysis Input File Name: Drewes Existing Addition.ribdx CF1 R -PRF -01 Page5of10 Window 30 Right Wall (Front -90) 5.0 1.0 1 5.0 0.71 0.73 Insect Screen (default) Existing No Window 31 Right Wall (Front -90) 5.0 1.0 2 10.0 0.71 0.73 Insect Screen (default) Existing No Window 32 Right Wall (Front -90) 5.0 1.0 4.5. 22.5 0.71 0.73 Insect Screen (default) . Existing No Window 33 Front 2 (- specify --135) 6.0 2.0 1.167 14.0 0.71 0.73 Insect Screen (default) Existing No Window 34 Left Wall 2 (- specify -225) 5.0 5.0 1.052 26.3 0.71 0.73 Insect Screen (default) Existing No Window 35 Rear Wall 2 (- specify -315) 5.0 3.8 1.384 26.3 0.71 0.73 Insect Screen (default) Existing No Window 36 Right Wall 2 (- specify -45) 5.0 5.0 1.052 26.3 0.71 0.73 Insect Screen (default) Existing No Window 37 Right Wall 2 (- specify -45) 5.0 6.0 1.8 54.0 0.71 0.73 Insect Screen (default) Existing No Window 38 Right Wall 2 (- specify -45) 5.0 6.0 1.8 54.0 0.71 0.73 Insect Screen (default) Existing No Window 39 Right Wall 2 (- specify -45) 5.0 2.5 1.12 14.0 0.71 0.73 Insect Screen (default) Existing No Window 40 Left Wall 3 (Left -180) 5.0 4.0 1 20.0 0.57 0.38 Insect Screen (default) New N/A Window 41 Back Wall (Back -270) 3.0 9.0 1 27.0 0.57 0.38 Insect Screen (default) New N/A Window 42 Back Wall (Back -270) 3.0 9.0 2 54.0 0.57 0.38 Insect Screen (default) New N/A Window 43 Back Wall (Back -270) 3.0 9.0 1 27.0 0.57 0.38 "Insect Screen (default) New N/A Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08162016-433 HERS Provider: Report Generated at: 2016-11-3012:39:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 12:38, Wed, Nov 30, 2016 Calculation Description: Title 24 Analysis Input File Name: Drewes Existing Addition.ribdx CFI R -PRF -01• Page 6 of 10 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up Window 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 2 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 3 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 4 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 0 0 0 1 0 0 0 0 0 Window 7 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 8 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 9 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 10 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 11 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 12 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 13 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 14 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 15 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 16 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 17 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 18 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 19 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 20 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 21 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 22 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 23 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 24 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 25 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 26 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 27 2 0.1 2 2 0 1 0 1 0 0 0 0 0 0 0 Window 28 2 0.1 2 2 0 1 0 1 0 0 0 0 0 0 0 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08162016-433 Report Generated at: 2016-11-3012:39:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 12:38, Wed, Nov 30, 2016 Calculation Description: Title 24 Analysis Input File Name: Drewes Existing Addition.ribdx CF1 R -PRF -01' Page 7 of 10 Window 29 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 30 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 3.1 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 32 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 33 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 34 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 35 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 36 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 37 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 38 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 39 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 40 20 0.1 20 20 0 0 0 0 0 0 0 0 0 Window 41 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 42 2 0.1 2 2 0 0 0 0 0 0 2L—J 0 0 Window 43 2 0.1 2 2 0 0 0 0 0 0 0 1 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers • Cavity / Frame: no insul. 12x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofExisting Living Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-11 /2x4 Default Wall 1978 to 1991 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R11 0.110 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Default Roof 1978 to Pres attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.049 Over Ceiling Joists: R-9.9 insul. • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofSitting Room Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R -19/2x6 R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 0.072 - Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board Ceilings (below L Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08162016-433 HERS Provider: Report Generated at: 2016-11-3012:39:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 12:38, Wed, Nov 30, 2016 Calculation Description: Title 24 Analysis Input File Name: Drewes Existing Addition.ribdx CF1 R -PRF -01. Page 8 of 10 SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Covered Slab Existing Living 5627 385 None 1 No Existing No Slab -on -Grade Sitting Room 255 18 None 0.8 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required — WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction M Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 2 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.62 EF 43000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08162016-433 Report Generated at: 2016-11-3012:39:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Daterrime: 12:38, Wed, Nov 30, 2016 Calculation Description: Title 24 Analysis Input File Name: Drewes Existing Addition.ribdx CFI R -PRF -01 Page 9of10 SPACE CONDITIONING SYSTEMS 01 02 03 04 0S 06 07 08 09 10 Multi -speed Heating System Cooling System System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12 Distribution Fan Floor Area Location Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition Existing Living'! Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 5882 Existing No Existing Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFumace - Fuel -fired central furnace 78 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 07 08 Efficiency 10 Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 10 12 No No N/A Location system Status Condition Verification Air Distribution Ducts located in attic HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not System 1 (Ventilated and specified) 8.0 Attic Attic None Existing No N/A Unventilated) IAO (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08162016-433 Report Generated at: 2016-11-3012:39:47 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Datelrime: 12:38, Wed, Nov 30, 2016 Calculation Description: Title 24 Analysis Input File Name: Drewes Existing Addition.ribdx CF1 R -PRF -01 Page 10 of 10 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Joan D. Hacker N, Company: SignatUre�Date: Insu-form, Inc. 11/30/2016 Address: CEA/HERS Certification Identification (If applicable): 72875 Fred Waring Drive, Suite C Ciry/StateQaim Desert, Ca 92260 Phone: 760-345-1352 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Company: Date Signed: Address: License: City/State/Zip: Phone: Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08162016-433 HERS Provider: Report Generated at: 2016-11-3012:39:47 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Drelves Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration 11113012016 Date Project Address 52-839 Via Savona La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 5,882 Addition 255 # of Units 1 INSULATION Construction Type Cavi(ft) Area Special Features Status Slab Unheated Slab -on -Grade - no insulation 5,627 Perim = 385' Existing Wall Wood Framed R11 3,570 Existing Roof Wood Framed Attic R 19 5,132 Existing Demising Wood Framed R 13 1 Existing Wall Wood Framed R 19 2,072 New Roof Wood Framed Attic R 38 255 New Slab Unheated Slab -on -Grade - no insulation 255 Perim = 18' New FENESTRATION Orientation Area(ft) I Total Area: 1,347 Glazing Percentage: 22.9 % U -Fac SHGC Overhang Sidefins New/Altered Average U -Factor: 0.57 Exterior Shades Status Left (S) 99.0 0.710 0.73 2.0 none Bug Screen Existing Rear (IM 130.0 0.710 0.73 2.0 none Bug Screen Existing Right (N) 621.3 0.710 0.73 2.0 none Bug Screen Existing Front (E) 153.3 0.710 0.73 2.0 none Bug Screen Existing Front (SE) 14.0 0.710 0.73 2.0 none Bug Screen Existing Left (SK9 26.3 0.710 0.73 2.0 none Bug Screen Existing Rear (NK9 26.3 0.710 0.73 2.0 none Bug Screen Existing Right (NE) 148.3 0.710 0.73 2.0 none Bug Screen Existing Left (S) 20.0 0.570 0.38 20.0 none Bug Screen New Rear (I49 108.0 0.570 0.38 2.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 4 Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status Existing Living Ducted Ducted Attic 8.0 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnemyPro, 6. by EnergySoft User Number. 2655 ID: Pae 13 of 18 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance aDDroach used. Exceptions may aDDly. Review the respective code section for more information. Building Envelope Measures: §I 10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §I 10.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. §I 10.8(1): The thermal emittance and aged solar reflectance values of the cool roofmg material meets the requirements of §I 10.8(1) when the installation of a cool roof is specified on the CFIR. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a §150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. §150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). §150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. §150.0(g)l: In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior walls, vented attics and unvented attics with air -permeable insulation. §150.0(g)2: In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of §150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 §150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §150.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. §I 10.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §I 10.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. §150.0(h)l: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in § 150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. §150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). §150.00)IA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system §150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. §150.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 2013 Low -Rise Residential Mandatory Measures Summary §150.00)2C: Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. §150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For §150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. §150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing enc approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)l: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than %< inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints §150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. §150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not §150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be § 150.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §150.0(m)13: space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of>_ 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of §150.0(o): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §150.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. _ 2013 Low -Rise Residential Mandatory Measures Summary §I 10.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - rammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §150.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §150.0(k)IB: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of §150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k)1C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)1D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)1F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §150.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (FMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. § 150.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. §150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. § I50.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing §150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and §150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § 150.0(k)9B: following requirements: i. Shall comply with §I50.0(k)9A; or ii. Shall comply with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in § 110.9 § 130.0 § 130.2 § 130.4 § 140.7 and § 141.0. §150.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). §I50.0(k)l 1: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9 130.0 § 130.1 § 130.4 § 140.6 and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of §150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: §150.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a) l: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10 through 110.10 e . § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through §I 10.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §1 10.10(b)l: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. §I 10.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. § 110.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Drewes Residence Date 11/30/2016 System Name Existing Living Floor Area 5,882 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 4 COIL CFM Total Room Loads 8,839 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per S tem 70,000 119,619 5,554 3,286 100,402 Total Output Btuh 280,000 0 Output Btuh/s ft 47.6 6,905 4,934 Cooling System 0 0 Output per System 58,000 0 0 0 0 Total Output Btuh 232,000 0 5,554 0 Total Output Tons 19.3 1 6,9051 4,934 Total Output Btuh/s ft 39.4 Total Output s ft/Ton 304.2 1 133,430 110,270 Air System CFM per System 2,210 HVAC EQUIPMENT SELECTION Airflow cfm 8,840 Existing 135,454 81,717 280,000 Airflow cfm/s ft 1.50 Airflow cfm/Ton 457.2 Outside Air % 0-0% Total Adjusted System Output (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 135,454 81,717 280,000 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF Outside Air Ar 0 cfm Supply Fan 8,840 cfm 69 OF 69 OF 99 OF ---- rd Heating Coil •-- 99 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 79168 OF 79 ! 68 OF 64 / 63 OF �. Outside Air -4r IBM 0 cfm Supply Fan Cooling Coil 8,840 cfm 79168 OF 65164 °FAL , 60.4% ROOM 78 / 68 OF EnergyPro 6. by EnergySoft User Number. 2655 ID: Page 18 of 18