Loading...
09-0329 (RER)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 09-00000329 Property Address: 52245 VIA SAVONA APN: 772-480-024- - - Application description: REMODEL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 44445 Ta�/ 4 4 Q" Applicant: Amor Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed un r provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business an Professional Code, and my License is in full force and effect. License las : B L' ense No.: 671203 DateV��Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERVIIT Owner: O'BRIEN MICHEAL & BILLIE JOE 52-245 VIA SAVONA LA QUINTA, CA 92253 ( O Contractor: PIERCE CORPORATION, ANDRE P.O. BOX 3420 PALM DESERT, CA 92261-342 (760)346-3228 Lic. No.: 671203 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/17/09 fGii u .i 42C 2 L CITY OF LA QUINTA WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier DELOS INS CO Policy Number 02DKRM12003819 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should beco a subject to th workers' compensation provisions of Section 3700ofthe Lab o Code,(II shal forth ' h com y with those provisions. �e��.� Applicant: ./l WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000) IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is c rect. I agree to comply with all city and county ordinances and state laws relating t wilding con ruction, and h reby authorize representatives of this c unty to enter upon the above-mentioned pro rty fo s cti n rpos i Date Signature (Applicant or Agentl: Application Number . . . . . 09-00000329 ------ Structure Information 7773 SF RESIDENCE ----- Other struct info . . . . . CODE EDITION 2007 ---------------------------------------------------------------------------- # BEDROOMS .00 Permit . . . BUILDING PERMIT Additional desc 688 SF PATIO CONV TO LIVING Permit Fee 382.00 Plan Check Fee 248.30 Issue Date . . . . Valuation . . . . 44445 Expiration Date 1/13/10 Qty Unit Charge Per Extension BASE FEE 252.00 20.00 6.5000 ---------------------------------------------------------------------------- THOU BLDG 25,001-50,000 130.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . . . 34.50 Plan Check Fee 8.63 Issue Date . . . . Valuation . . . . 0 Expiration Date _ 1/13/10 Qty Unit Charge Per Extension BASE FEE 15.00 26.00 .7500 ---------------------------------------------------------------------------- PER ELEC DEVICE/FIXTURE 1ST 20 19.50 Permit . . MECHANICAL Additional desc . . Permit Fee . . . . 37.50 Plan Check Fee 9.38 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/13/10 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 1.00 9.0000 ---------------------------------------------------------------------------- EA MECH B/C <=.3HP/100K BTU 9.00 Permit . . . . . . PLUMBING Additional desc . Permit Fee 21.00 Issue Date . . . . Expiration Date . . 1/13/10 Qty Unit Charge Per LQPERAIIT Plan Check Fee . . 5.25 Valuation . . . . 0 Extension Application Number . . . . . 09-00000329 Permit . . . . . . PLUMBING Qty Unit Charge Per Extension BASE FEE 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB FIXTURE DRAIN/VENT REP/ALT 3.00 ---------------------------------------------------------------------------- Special Notes and Comments 688 SF PATIO CONVERSION TO LIVING AREA. DWELLING SQUARE FOOTAGE 1NCRF $P.n TO 7773 SF. 2007 CODES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 ENERGY REVIEW FEE 24.83 STRONG MOTION (SMI) - RES 4.44 Fee summary Charged Paid Credited ----------------------------------------------- ---------- Due Permit Fee Total 475.00 .00 .00 475.00 Plan Check Total 271.56 .00 .00 271.56 Other Fee Total 31.27 .00 .00 31.27 Grand Total 777.83 .00 .00 777.83 LQPERNIIT c, Bin # City of La Quinta Building U Safety Division P.O. Box 1504, 78-495 Calle Tampico Permit # La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Trackir:g Sheet Project Address:' 04444A A S4,16a„ Owner's Name: k411Wt LLIp dl A. P. Number: 11,� . �� OZ,d, $ Address: Legal Description: TP/0. Ig9A ,O. ;11156. City; ST, Zip:*,UAqd0 A, eog Contractor: ,Wolff �jf 0j2(?p#A Telephone: Address: 44.194 i9f P eA4Y0 j *A&V Project Description: GpOA (a, City, ST, Zip: MAW WAP -t. ��i� GOf�i2%)KNEW - Telephone: '' 6o .3%2$ State Lic. # : City Lic. #: � fi� Arch., Engr., Designer: Address: Z 511 liviloe )WO. 43114(w City, ST, Zip4wi—, x 9x14& Telephone:14- 4 4 - ZC1Q6 Constivation Type: Occupancy: State Lic. #: 09 fug Project type (circle one): New Add'n Alter epair Demo Name of Contact Person: r,7joil V1 Sq. Ft.: Stories: # Units: Telephone # of Contact-Person:160 • M6 0gs K - 30 Estimated Value of Project:4 215.o APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACIUNG PERMIT FEES Plan Sets Plan Check submitted 3 Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Cheek Ealance Energy .Calcs. Plans ' iiccked up _ -Construction_ - FIQOd plain plan Plans resubmitted . Mechanical - Grading. plan 2'" Review, ready for correctionsfissue Electrical Subcontactor. List Called'Contact Person 1 1 Plumbing Grant Deed Plans. picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees A1C3ts '�/7 tfeSA- rta`c� rho �n� �)r,) Total Permit Fees a 4 Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA AMOUNT LEVEL ONE AMOUNT: LEVEL Two AMOUNT: MmcaTtON AMOUNT: COMM/M. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Michael Obrien Date: 08/14/09 Owner's Name: Michael Obrien Phone No. • (760) 880-0162 Project Address: 52-245 Via Savona, La Quinta, CA Project Description: Covered Patio Conversion Living Area of Existing SFD APN: 777-140-002 Tract #: Lot #'s: 118 Type of Development: Residential XXL Commercial Industrial Total Square Feet of Building Area: 688 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is corre-.t and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf offhe owner/developer. Dated: 08/14/09 Signature: •s*:ssss*sssssssss*s•�s*s*sssssss*•*s*ssss.#*:sss*ss«s�#ss**sss#*ss�vss SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Total Square Footage 688 Sg, Ft. Amount per Sq.Ft. $ 2.97 Amount Collected $ 2,043.36 Building Permit Application Completed: Yes/No By: Jamie T. Brown, Asst. Supt., Business Services Certificate issued by: Leticia C. Torres, Facilities Analyst Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires s Di-trict provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice 'shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as terein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts oo the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. LT:c/mydocs/devfees/certificate of compliance form tablesTO USE.doc 9/11/08 i TITLE 24 REPORT Title 24 Report for: Lot 118 Via Savona * The Hideaway La Quinta, CA 92253 Project Designer: BBG Architects 20-371 Irvin Ave., Suite 120 Santa Ana Heights, CA 92707-5651 (714) 434-2506 Report Prepared By: Micah Combs CM Energy Consulting P.O. Box 4655 Palm Desert, CA 92261 (760) 449-1308 F cz' i Y r LA QUINTA � i UILDING & SAFETY DEPT. APPROVED FON CONSTRUCTION Job Number: ; c�,arE h Y*'Itq Date: 6/22/2009 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This.pP authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy E This program developed by EnergySoft, LLC - www.energysoft.com. i has approo d is a\andar EnergyPro 4.4 by EnergySoft Job Number: User Qmber103 : 74 \I�► 1 sw D' f'1 .n L'—'D < < L—&-- TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting 1 2 3 12 14 EnergyPro 4.4 by EnergySoft Job Number: User Number: 7403 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R Lot 118 Project Title r7i22i20ng Date via gavona * The Hideaway I a Ql inta Project Address Building Permit # LA, Ener C In�ltinn (760) 449-1308 Documentati Author Telephone plan Check/Date Fnern CompliNrice Method CA Cute lone 19 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 1.76 2.26 -0.51 Space Cooling 57.59 52.24 5.34 Fans 8.18 9.81 -1.63 Domestic Hot Water 3.52 3.96 -0.44 Pumps 0.00 0.07 -0.07 Totals 71.04 68.35 2.69 Percent better than Standard: Building Type: iX� Single Family ❑ Addition ❑ Multi Family ❑ Existing + Add/Alt Building Front Orientation: (E) 90 deg Fuel Type: Natural Gas Fenestration: Area: 1,390 ft2 Avg. U: 0.37 Ratio: 19.1% Avg. SHGC: 0.32 BUILDING ZONE INFORMATION Zone Name Floor Area Volume HVAC #1 1,._x66 17 g HVAr 99 1 744 17 4 HVAC #3 1 574 ?5"7 HVAC #4 1 326 13_? OPAQUE SURFACES Insulation Act. Type Frame Area LI -Fac. Cay. Cont. Azm. Tilt Rnnf Wppxl 1 n55 n nr.1 R_lq -n n _0 n Wall Wnnd 599 0110 R-11 R -nn n 90 Wall W and 63 o ] 1Jl 11 SIL _ILII Wall Wnnd 214 o 11 n R-11 R -n n _90 An Wall Wnnd 309 0110 R-11 R -n n 1 Rn _90 Wall WnrA 946 n_11n R_11 R -nn 97n gn wall— Wnnd— 3R —n 11n R_11 R-0 0 97n An Rnnf Wnrkl 1�334 nn51 R_lq R -nn n n Wall Wnnd 130 0110 R_11 R -nn jj 90 Wall Wnnd 137 Q110 R_11 R-n_n gn 90 Wall Wnnd 9nn 0110 R_11 R_n0 An 90 wall WnnH inn o11n P-1 1 R-()0 ign gn Wall Wnrxi 90 n 110 R_11 R-0.0 1Rn gn Wall Wnnd 1R nun R_11 R-00 P70 gn Rnnf Wnnd 1 574 n 051 R_1q R-0 n 0 n Wall Wnod 111 n11n R_11 R -Q0 0 go Wall Woori— 36 _0.110. R_11 R -n n n gn nnor Nnna 94 n 600 Nnna R -n n a gn Wal1 Wnnd 174 011n R_11 R -n n gn 90 Wall Wnnd 556 n_11n R_11 R -nn 180 qn Wall Wond 60 0110 R_11 R -n n 1R0 gn Wall wood 140 0110 R_11 R -n n P70 90 Rnnf Wnnd 1,396 0051 R-19 R-0 n _n wall Wood— 364 n110 R_11 R -nn 0 gn Wall WoWo—oad— 34R n11aR-11 R -nn 90LgD Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: # of Thermostat Units Zone Type Type n 97 rond6tionAd Sethark X24 rnndifinned Sathark 022_ Conditioned Sethack 018 Conditioned Setback 7,294 ft2 n/a ft2 0 ft2 5,968 ft2 10.0 ft 1.00 Vent Hgt. Area n/a —2 n/a _2 n/a _2 n/a Gains Condition Y / N Status JA IV Reference Location / Comments I EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:3 of 14 1 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R Lot 118612/ 009 Project Title Date gavnna * The Hideaway I a Q, junta _V_ia Project Address Building Permit # Fn rnv Cnnsiiltinn (760) 449-1308 DocumentatiW Author Telephone Plan Check/Date FnernyPrn Compli1rice Method CA Climate Zone 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 1.76 2.26 -0.51 Space Cooling 57.59 52.24 5.34 Fans 8.18 9.81 -1.63 Domestic Hot Water 3.52 3.96 -0.44 Pumps 0.00 0.07 -0.07 Totals 71.04 68.35 2.69 Percent better than Standard: Building Type: (J Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (E) 90 deg Natural Gas Area: 1,390 ft' Avg. U: 0.37 Ratio: 19.1% Avg. SHGC: 0.32 BUILDING ZONE INFORMATION Zone Name Total Conditioned Floor Area Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: # of Floor Area Volume Units Zone Tvr)e OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Wnrwl 471 0 110 R_11 _n n ISO _90 Wall Wnnrl ;)Rg n 11d R_11 R -n n 270 9p Rnnf Wnnrl 674 n 051 _E19 R -n 0 Wall Wood 70 _ 0110 P-1 113-0 n 0 90 Wall W nnrl 75 n11n R-11 R -n n 1 Rn Ap Wall Wnnrl IRR 0110 R_11 R-n_n P70 Ap Gains Condition Y / N Status JA IV Reference 7,294 n/a 5,968 10.0 1.00 ft2 ft2 ft2 ft2 ft Thermostat Vent Type Hgt. Area Setback— n/a Location / Comments i EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:4 of 14 1 Certificate Of Compliance :Residential (Part 2 of 4) CF -1 R Lot 118 6/22/2009 Project Title Date FENESTRATION SURFACES True Cond. # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Location/ Comments 1 2 Window Window Right Right (N) in n 018 NFRC n.o NFRC _0 i_ New Siarra Panifir. Clad (I n/F) (mnt (N) 10.0 0.380 NFRC 0_30 NFRC 0 90 New 9(6k% Pacific Clad (Lo/E) Cmnt 70NF #1 ZONE #1 3 Window Right (N) 20.0 0.390 NFRC 0_28 NFRC 0 90 New W Pacific Clad (Lo/E) Frnch Dr ZONE #1 4 Window Right (N) 48.0 0.350 NFRC 0_38 NFRC 0 90 New Sierra Pacific Clad (Lo/E) Fxd Wdw ZONE #1 5 Window Right (N) 10.0 0.380 NFRC 0_30 NFRC 0 90 New Sierra Pacific Clad (Lo/E) Cmni ZONE #1 -6- Window Right (y) 10.0 0.380 NFRC 0_30 NFRC 1E) Cmnt ZONE #1 Z Window Front (E) 20.0 035350 NFRO_0 3 NFRC 90_ qQ New Pacific Clad ( o/ ) Fxd Wdw ZONE #1 8 Window Front (E) 40.0 0.390 NFRC 0_28 NFRC 90 90 New Sierra Pacific Clad (Lo/E) Frnch Dr ZONE #1 3 Window Front (E) 20.0 0.350 NFRC 0"3g NFRC _90_ qQ New Sierra Pacific Clad (Lo/E) Fxd Wdw ZONE #1 -M Window Front (E) 48.0 0.350 NFRC 0.3g NFRC 90_ -0-New Sierra Pacific Clad (Lo/E) Fxd Wdw ZONE #1 11 Window Left (S) 40.0 0.390 NFRC 0.28 NFRC 180 90 New Sierra Pacific Clad (o/E) Frnch Dr ZONE #1 12 Window Left (S) 6.0 0.380 NFRC 0_30 NFR 180 90 New Sierra Pacific Clad (Lo/E) Cmnt ZONE #1 13. iA Window Window I eft Left (S) F; 0_ 0.380 NFRC 00.30 NFRC 180 _Q- New a Pacific Clad (er) Cmnt (S) 6.0 0.380 NFRC 0_30 NFRC 180 90 New 481d Pacific Clad (LoE Cmnt ZONE #1 ZONE #1 15 Window Rear (W) 6.0 0.380 NFRC 0_30 NFRC 270 90 New 99% Pacific Clad Lo/E) Cmnt ZONE #1 _a Window Rear (W) 18.0 0.380 NFRC 0.30 NFRC 270 90 New Wa Pacific Clad (Lo/E) Cmnt ZONE #1 17 Window Rear (W) 40.0 0.390 NFRC 0_28 NFgC 270 90 New gid% Pacific Clad (Lo/E) Frnch Dr ZONE #1 1$ Window Rear (W) 16.0 0.410 NFRC 0_32 NFRC 270 90 New Pozzi Clad (Lo/E) Fxd Wdw ZONE #1 -M Window Rear (W) 16.0 0.410 NFRO 032 NFRC 270 PIC) New Pozzi Clad (Lo/E) Fxd Wdw ZONE #1 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Area Thick. Heat Inside Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 _ 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 _ 8 Bug Screen 0.76 9 Bug Screen _ 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen _ 0.76 13 Bug Screen 0.76 14 Bug Screen _ 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen _ 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Run Initiation Time: 06/22/09 09.34.44 Run Code- 1245688484 EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:5 of 14 Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Tile in Mortar 390 0.75 24 0_67 0 n/a New ZONE #1 / Interior Mass Concrete, Heavyweight 390 4.00 28 0_98 0 26-A1 New ZONE #1 / Slab on Grade Concrete, Heavyweight 1.576 4.00 28 0_98 2 26-A1 New ZONE #1 / Slab on Grade Tile in Mortar 340 0.75 24 0_67 0 n/a New ZONE #2 / Interior Mass Concrete, Heavyweight 340 4.00 28 0_98 0 26-A1 New ZONE #2 / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 193 None No Insulation 26-A1 New ZONE #1 Slab Perimeter 54 None No Insulation 26-A1 New ZONE #2 Slab Perimeter 118 None No Insulation 26-A1 New ZONE #3 Slab Perimeter 49 None No Insulation 26-A1 New ZONE #5 Run Initiation Time: 06/22/09 09.34.44 Run Code- 1245688484 EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:5 of 14 Certificate Of Compliance :Residential (Part 2 of 4) CF -1 R Lot 118 6/22/2009 Project Title Date FENESTRATION SURFACES True Cond. # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Location/ Comments 20. 21 Windnw Window Right Front (N) 1120 nn n .36 NERC ngNFRC �_ -9L Naw Sierra Pnrifir. Clad (I n/F) siring (El 100.0 0.360 NFRC 0_32 NFRC 90 90 New Sierra Pacific Clad (Lo/E) Sldng Dr ZQNF #9 Dr ZONE #2 22 Window Front (E) 28.0 0.530 116-A 0_53 116-B 90 90 New Double Wood Default (Clear) ZONE #2 23 Window Left (S) 10.0 0.380 NFRC 0_30 NFRC 180 90 New Sierra Pacific Clad Lo/E) Cmnt ZONE #2 24 Window Left (S) 10.0 0_380 NFRC 0_30 N F R -C 180 90 New Pacific Clad (Lo/E) Cmnt ZONE #2 25 Window Rear (W) 80.0 0_360 NFRC 0_32 NFRC 270 90 New (Lo/E) Sldng Dr ZONE #2 2a Window Front (E) 8.0 0y380 NFRC 03 NFRC qQ _gQ New Sierra Pacific Clad (Lo/E) Cmnt ZONE #3 27 Window Front (E) 18.0 0.380 NFRC 0_30 NFRC 90 90 New W6K%Pacific Clad Lo/E) Cmnt ZONE #3 2$ _Window Front (Fa 18.0 0_380 NFRC 03 NFRG 90 qQ New Pa .. .lad (Lo/ ) Cmnt ZONE #3 2a _Window Front (F) 12.0 0_350 NFRC 0038 NFRC 90 qn New W4ffi Pacific Clad (Lo/E) Fxd Wdw ZONE #3 M Window Left (S) 19.0 0_390 NFRC 0_28 NFRC 180 90 New Sierra Pacific Clad (Lo/E) Frnch Dr ZONE #3 31 Window Left (S) 12.5 0_380 NFRC 0_30 NFRC 180 90 New Sierra Pacific Clad (Lo/E) Cmnt ZONE #3 22 33 Window Window I eft Left (S) 15.0 X50 NFRC 03 NFRC 180 q0_ New Pacific Clad (I n/E) Fxd Wdw_ZONE #3 (S) 6.0 0_350 NFRC 0_38 NFRC 180 90 New Sierra Pacific Clad (Lo/E) Fxd Wdw ZONE #3 34 Window Rear (W) 50.0 0.390 NFRC 0_28 NFRC 270 90 New Sierra Pacific Clad (Lo/E) Frnch Dr ZONE #3 25 Window Rear (W) 25.0 0.350 NFRC 0_38 NFRC 270 90 New Sierra Pacific Clad (Lo/E) Fxd Wdw ZONE #3 3 Window Rear (W) 25.0 0.350 NFRC 0_38 NFRC 270 90 New Sierra Pacific Clad (Lo/E) Fxd Wdw ZONE #3 2Z Window Right (N) 10.0 0.380 NFRC 0_30 NFRC 0 90 New Sierra Pacific Clad (Lo/E) Cmnt ZONE #4 -M Window Right ()y) 13.5 0.380 NFRC 03 NFRC 0 qQ New §W(A% Pacific Clad (J o/E) Cmnt ZONE #4 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1 IN.w INTERIOR AND EXTERIOR SHADING Bug Screen Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 21 Bug Screen 0.76 _ 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 _ 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen _ 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Run Initiation Time: 06/22/09 09:34:44 Run Code: 1245688484 EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:6 of 14 Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight 1.409 4.00 28 0_98 2 26-A1 New ZONE #2 / Slab on Grade Tile in Mortar 310 0.75 24 0_67 0 n/a New ZONE #3 / Interior Mass Concrete, Heavyweight 310 4.00 28 0_98 0 26-A1 New ZONE #3 / Slab on Grade Concrete, Heavyweight 1.264 4.00 28 0_98 2 26-A1 New ZONE #3 / Slab on Grade Tile in Mortar 260 0.75 24 0_67 0 n/a New ZONE #4 / Interior Mass PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 06/22/09 09:34:44 Run Code: 1245688484 EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:6 of 14 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Lot 118 6/22/2009 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazing Type Comments M 40 Windnw Window Frnnt Front (F) (E) 20_0 n_39n NFRC 1 9 NFRC qQ_ An New Siarra Parifir. Clad (I n/F) Frnch Or ZQNF #4 4.5 0.380 NFRC 0_30 NFRC 90 90 New Sierra Pacific Clad Lo/E) Cmnt ZONE #4 41 Window Front (E) 4.5 0.380 NFRC 0_30 NFRC 90 90 New Pacific Clad Lo/E) Cmnt ZONE #4 42 Window Front (E) 4.5 0.380 NFRC 0.30 NFRC 90 90 New 96 Pacific Clad Lo/E) Cmnt ZONE #4 43_ Window Front (E) 6.0 0.38 NFRC 0_30 NFRC 90 90 New WA Pacific Clad (Lo/E) Crnnt ZONE #4 44 Window Left (S) 10.0 0_380 NFRC 0_30 NFRC. 180 90 New Pacific Clad (Lo/E) Cmnt ZONE #4 45. Window Left (S) 6.3 038 NFRC 01 NFRC 180 qQ_ New Pacific Clad (Lo/F) Cmnt ZONE #4 46 Window Rear (W) 8.0 0.380 NFRC 0.30 NFRC 270 90 New 9Oft Pacific Clad Lo/E) Cmnt ZONE #4 4Z Window Rear (W) 10.0 0=380 NFRC 0_30 NFRC 270 510 New Pacific Clad ( o/E) Cmnt ZONE #4 48_ Window Rear OyJ 40.0 0=390 NFRC 0_28 NFRC 270 gQ_New WO& Pacific Clad (Lo/F) Frnch Dr ZONE #4 4q Window Rear -(WI 40.0 0_390 NFRC 0_28 NFRC 270 90 New Sierra Pacific Clad-(L(21E) Frnch Dr ZONE #4 50 Window Left (S) 48.0 0_360 NFRC 0_32 NFRC 180 90 New Sierra Pacific Clad (Lo/E) Sldng Dr ZONE #5 51 Window Rear (W) 227.5-50360 NFRC 032 NFRC 270 _g.Q- New Sierra Pacific Clad (I o/F) SIdnB Dr ZONF #5 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Area Thick. Heat Inside Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 _ 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 _ 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 _ 48 Bug Screen 0.76 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 06/22/09 09.34.44 Run Code: 1245688484 EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:7 of 14 Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Tile in Mortar 679 0.75 24 0_67 0 n/a New ZONE #5 / Interior Mass Concrete, Heavyweight 612 4.00 28 0_98 0 26-A1 New ZONE #5 / Slab on Grade Concrete, Heavyweight 67 4.00 28 0_98 2 26-A1 New ZONE #5 / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 06/22/09 09.34.44 Run Code: 1245688484 EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:7 of 14 A -ti Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Lot 118 Tank Energy Duct Duct Condition 6/22/2009 Project Title Heating Cooling Location Date Tested? HVAC SYSTEMS Ducted Ducted Attic 8.0 New No HVAC #2 Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC #1 Central Furnace 92% AFUE Split Air Conditioner 15.0 SEER New Setback HVAC #2 Central Furnace 92% AFUE Split Air Conditioner 15.0 SEER New Setback HVAC #3 Central Furnace 92% AFUE Split Air Conditioner 15.0 SEER New Setback HVAC DISTRIBUTION Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC #1 Ducted Ducted Attic 8.0 New No HVAC #2 Ducted Ducted Attic 8.0 New No HVAC #3 Ducted Ducted Attic 8.0 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Rheem HE80-199 Large Gas Recirc/Time+Temp 2 199,000 78 New 0.92 1.17% 0.0 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (p1r Busi ess8A Professions Code) Name: V� t7 _ W Title/Firm: BBG Architects Address: 20-371 Irvin Ave., Suite 120 Santa Ana Hei hts CA 707-5651 Telephone: 14 4 4-2 O6 I I Lic. #: (signature) W$ (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Micah Combs Title/Firm: CM Energy Consulting Address: P.O. Box 4655 Palm Desert, CA 92261 Tel phon 760 449-1308 774 - (sign (date) Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Lot 118 Duct Condition Ducts Location Heating Cooling Location R -Value Status 6/22/2009 Project Title 8.0 New No HVAC #5 Ducted Ducted Attic Date No HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC #4 Central Furnace 92% AFUE Split Air Conditioner 15.0 SEER New Setback HVAC #5 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC #4 Ducted Ducted Attic 8.0 New No HVAC #5 Ducted Ducted Attic 8.0 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (peBusing Name: tCX-IIVI V ss & rofessions Code) �IIr�L� Title/Firm: BBG Architects Address: 20-371 Irvin Ave.. Suite 120 Santa Ana Hei hts CA 2707-5651 Telephone: 714 *-150q 50 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Micah Combs Title/Firm: CM Energy Consulting Address: P.O. Box 4655 Palm Desert, CA 92261 Telephone: 760 449-1308 -7' (sign (date) ' Certificate Of Compliance :Residential (Part 4 of 4) CF -1 R Project Title 6/22/2009 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The Roof "R-38 Roof (R.38.2x14.16)" includes a Radiant Barrier. The DHW System "Rheem HE80-199" is a Large Gas water heater with Pilot Loss = 0 btuh. HIGH MASS Design - Thermal Mass: 390 sqft Tile in Mortar Interior Mass, 0.75" thick at Master Suite and Guest Suite HIGH MASS Design - Thermal Mass: 390 sqft Exposed Slab Floor, 4.00" thick at Master Suite and Guest Suite HIGH MASS Design - Thermal Mass: 1576 sqft Covered Slab Floer, 4.00" thick at Master Suite and Guest Suite HIGH MASS Design - Thermal Mass: 340 sqft Tile in Mortar Interior Mass, 0.75' thick at Living Area HIGH MASS Design - Thermal Mass: 340 sqft Exposed Slab Floor, 4.00" thick at Living Area HIGH MASS Design - Thermal Mass: 1409 scift Covered Slab Floor, 4.00" thick at Living Area HIGH MASS Design - Thermal Mass: 310 sqft Tile in Mortar Interior Mass, 0.75' thick at Guest Bedroom and Kitchen HIGH MASS Design - Thermal Mass: 310 sgft Exposed Slab Floor, 4.00" thick at Guest Bedroom and Kitchen HIGH MASS Design - Thermal Mass: 1264 sqft Covered Slab Floor, 4.00" thick at Guest Bedroom and Kitchen HIGH MASS Design - Thermal Mass: 260 sgft Tile in Mortar Interior Mass, 0.75' thick at Upstairs Guest Suite HIGH MASS Design - Thermal Mass: 679 sgft Tile in Mortar Interior Mass, 0.75' thick at Loggia HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field The HVAC System "HVAC #1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "MAYTAG PSA4BF/ PGF1 TC (5 Ton)" includes credit for a 13.0 EER Condenser. The HVAC System "HVAC #2" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "MAYTAG PSA4BF / PGFITC (5 Ton)" includes credit for a 13.0 EER Condenser. The HVAC System "HVAC #3" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "MAYTAG PSA4BF / PGF1 TC (5 Ton)' includes credit for a 13.0 EER Condenser. The HVAC System "HVAC #4" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "MAYTAG PSA4BF / PGF1 TC (5 Ton)' includes credit for a 13.0 EER Condenser. The HVAC System "HVAC #5" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "MAYTAG PSA1 BD / PGC1 RA (2 Ton)' includes credit for a 11.0 EER Condenser. L EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page: 10 of 14 1 Certificate Of Compliance :Residential (Part 4 of 4) CF -1 R Lot 118 6/22/2009 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )asea on the aaequacy of the special fustmcauon ana aocumentauon submittea. HIGH MASS Design - Thermal Mass: 612 sqft Exposed Slab Floor, 4.00" thick at Loggia HIGH MASS Desiqn - Thermal Mass: 67 soft Covered Slab Floor, 4.00" thick at Loaaia Plan I Field HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Paae:11 of 14 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures *§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ Q ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ •§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ,§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ 0 ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ FX1 ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑X ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110.13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page: 12 of 14 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ® ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ® ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑X ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ® ❑ b. Cover for outdoor pools or outdoor spas. ❑ ® ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑X ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ a ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page: 13 of 14 Residential Kitchen Liahting Worksheet WS -5R Lot 118 6/22/2009 Project Title Date At least 50%of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchell Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1) 28w Compact Fluorescent Quad 2 Pin Yes X No 34.0 x 13 = 442 or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No 11 x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 442 B: 0 COMPLIES IF A i B YES ® NO ❑ L_ EnergyPro 4.4 by EnergySoft User Number: 7403 Job Number: Page:14 of 14 1