BRES2016-0183f:
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
TA
. v
h -4
aw
DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number:
BRES2016-0183
Property Address:
80861 VIA SAVONA
APN:
777130019
Application Description:
DREW WELK / FIRE PLACE REMODEL
Property Zoning:
Application Valuation:
$42,500.00
Applicant:
MONARCH HOMES DESERT DIVISION INC DBA DA
49-950 JEFFERSON ST #130-134
INDIO• r.A 97701
Ii
LICENSED CONTRACTOR'S DECLARATION
I hereby'affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of t e Busines d Professions Code,
and my License is in full force and effect.
License Class: B Li ense No.: 457228 J
Dater Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a'
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(� I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
L -D I, as owner of the property, am exclusively contracting with licensed contractors
to.construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(' - I I am exempt under.Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby.affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).•
Lender's Name:.
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: . 8/22/2016
Owner:
FUSION INV
540 HILLSIDE DR'EIn Q
SEATTLE, WA 922!3
AUG 2 2 2016
Contractor: CITY OF LAOUINiA
MONARCH HOMES-'BOESERN D'[VISIION INT% A%"V
49-950 JEFFERSON ST #130-134
INDIO,CA82201.
(760)413-8863
Llc. No.: 457228
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code; for the performance
f tP3O
wh' this permit is issued.
and will maintain workers' compensation insurance, as required by
Se i:the Labor Code, for the performance of the work for which this permit
is issued:.My workers' compensation insurance carrier and policy number are:
Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 9045509 .
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'.
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 f the L or Code, I shall forthwith
comply W14 -hose ovisions.
Date: Applicant:
WARNING: F LURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES.UPTO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
'APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefitwork is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit. .
2. Any permit issued as a result of this application becomes null and.void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances an sta a ws relating to buildi g
construction, and hereby authorize representativesMttnter upon t
above -mention property for inspection purposes
Date: ignature (Applicant or A
Date: 8/22/2016
Application Number: BRES2016-0183
Owner:
PropertyAddress: 80861 VIA SAVONA
FUSION INV
APN:: 777130019
540 HILLSIDE DR E
Application Description: DREW WELK / FIRE PLACE REMODEL
SEATTLE, WA 92253
Property Zoning:
Application Valuation: $42,500.00.
Applicant:
Contractor:
MONARCH HOMES DESERT DIVISION INC DBA DA
MONARCH HOMES DESERT DIVISION INC DBA DA
49-950 JEFFERSON ST #130-134
49-950 JEFFERSON ST #130-134
INDIO, CA 92201
INDIO, CA 92201
'
(760)413-8863
Llc. No.: 457228
Derail: NEVV--Z)U1DOOR FIREPLACE; RELOCATE BBQ, INSTALL NEW DOUBLE FRENCH DOORS @ EX&1N`d WINDOW OPENING,, NEW WINDOW ALTERATION @
GARAGE WALL. PER 2013 CRC,2013 CPC AND 2013 ELEC CODES.
C
•e
DESCRIPTION' ACCOUNT QTY AMOUNT
BSAS SB1473 FEE 101-0000-20306
0 $2.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DEVICES, FIRST 20
101-0000-42403
0
$24.17
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DEVICES, FIRST 20 PC
101-0000-42600
0
$24.17
Total Paid for ELECTRICAL: $48.34
DESCRIPTION
ACCOUNT
QTY.
AMOUNT
FIREPLACE
101-0000-42400,
0
$145.03
' `'' DESCRIPTION
ACtOUM•` "'' "`
QTY ''
AMOUNT
FIREPLACE PC
101-0000-42600
0 •
$217.55
\ Total Paid for FIREPLACE: $362.58
DESCRIPTION
ACCOUNT
QTY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS
101-0000-42401
0
$12.09
DESCRIPTION
ACCOUNT
QTY
AMOUNT
GAS SYSTEM; 1-4 OUTLETS,
101-0000-42401
0
$12.09
DESCRIPTION.
ACCOUNT
QTY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS PC
101-0000-42600
0
$24.17
DESCRIPTION
ACCOUNT
QTY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS PC
101-0000-42600
0
$24.17
Total Paid for PLUMBING FEES: $72.52
DESCRIPTION
ACCOUNT
QTY
AMOUNT'
SMI - RESIDENTIAL
101-0000-20308
0
$5.53 T
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $5.53
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DOOR/WINDOW, REPLACE FIRST
101-0000-42400
0
,$60.91
DESCRIPTION
ACCOUNT
QTY
AMOUNT,
DOOR/WINDOW, REPLACE, FIRST 7 PC
101-0000-42600
0
$110.22
Bin #
City of La Quinta
Building 8t Safety Division
78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
I $3 Building Permit Application and Tracking Sheet i
Permit #
®Ib
Project Address:
Owner's Name:
A. P. Number: bo
Address:
Legal Description:
City, ST, Zip:
'I` !e hone:
e P
tr
Con act r•
o.
Address:
Project Description:
City, ST, Zip: Z
r
Teleph o .
P
T ne•LA
G
OC is
$&a Z 6;4
M
State Lic. # :
City Lie. #:
( k
Arch., Engr., Designer: roi Z�
r `
Address: V4 50gs
City., ST, Zip:
jL4.
hone:
Telephone:
a2
Can fracttan
on Type: Occupancy:
cY:
Lic. #:
airState
Project hPa (circle one): New Add'n Alter r Re Demo
Name of Contact Person-At'"Sq.
: 1
Ft.:
# Stories:
# Units:
Telephone # of Contact Person: Q
t
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
iY
Submittal
Req'd
Rec'd
TRACKING
PERMITTEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Clieck Deposit
Truss Cales.
Called Contact Person
Plan Check Balance
Title 24 Cates.
Plans picked up
Construction
Floodplain plan
Plans resubmitted
Mechanical
Grading plan
2"a Review, ready for corrections/issue
Electrical
Subcontactorlist
Called Contact-Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN ROUSE:-
3r! Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fecs,
Total Permit Fees
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CF2R-ALT-0S-E IRAvicar) OR1141
CERTIFICATE OF INSTALLATION
v CF2R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
(Page 1 of 15)
Project Name: Drew Welk and Aya Hamilton Interior Remodel
Enforcement Agency: City of La Quinta
Permit Number:
Dwelling Address: 80861 Via Savona
city La Quinta
Zip code 92253
This compliance document is only applicable to simple alterations that do not require HERS verification for compliance. When HERS verification is required, a CFIR-ALT-01 shall first be registered
with a HERS Provider Data Registry.
Alterations to Space Conditioning Systems that are exempt from HERS verification requirements may use the CFIR-ALT-05 and CF2R- ALT -05 Compliance Documents. Possible exemptions from duct
leakage testing include: less than 40 ft of ducts were added or replaced; or the existing duct system was insulated with asbestos, • or the existing duct system was previously tested and passed by a
HERS Rater. If space conditioning systems are altered and ore not exempt from HERS verification, then a CFIR-ALT-02 must be completed and registered with a HERS Provider Data Registry.
Alterations that utilize close Cell Spray Polyurethane Foam (ccSPF) with a density of 1.5 to less than 2.5 pounds per cubic foot having an R -value other than 5.8 per inch, or Open Cell Spray
Polyurethane Foam (ocSPF) with a density of 0.4 to less than 1.5 pounds per cubic foot having an R -value of 3.6 per inch, shall complete and register a CF1R-ALT-01 with a HERS Provider Data
Registry.
If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they are
responsible. Alternatively, the person with chief responsibility for construction shall prepare and sign this certificate for the entire construction. All applicable Mandatory Measures shall be met.
Temporary labels shall not be removed before verification by the building inspector.
A. GENERAL INFORMATION
01
Project Name:
Drew Welk and Aya Hamilton Interior Remode 02
Date Prepared:
07/19/2016
03
Project Location:
80861 Via Savona 04
Building Front Orientation (deg):
north
05
CA City:
La Quinta 06
Number of Dwelling Units with Additions:
1
OT
Zip Code:
92253
Fuel Type:
gas
09
Climate Zone:
CZ15 BUILD10
Total Conditioned Floor Area (ft) (Addition):
0
11
Building Type
SINGLE RESIDENPE APPRCC®\ /r ED 12
Slab Area (ft'):
0
13
Project Scope:
window and french door in Yl YQTION
EMMA
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014
LV l
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CF2R-ALT-05-E (Revised 06/14) SAI Ir no�lln Cf ICOCV /�AII001l1
I vvrvnvnoalvly
CERTIFICATE OF INSTALLATION CF2R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 2 of 15)
Project Name: Drew Welk and A a Hamilton Interior Remodel Enforcement Agency: :=Umber;
Y City of La Quinta
.
Dwelling Address: 80861 Via Savona ci" La Quinta
Zip Code 92253
I
Insulation
The altered components shall comply with all applicable requirements in The Energy Efficiency Standards Sections 110. 7, 110.8, 150.0; All joints, penetrations and other openings in the building
envelope that are potential sources of air leakage shall be caulked gasketed weather stripped, or otherwise sealed to limit infiltration and exhilaration.
B. ROOF/CEILING INSULATION
01
02
03
04
05
06
07
08
09
10
1. D.
Manufacturer &Brand
Framing
Material
Framing Size &
Spacing
Insulation
Type
ESR Number
Cavity Insulation
R -value
Insulation
Depth
(inches)
Above Deck
Insulation
R -value
Below Deck
Insulation
R -value
1
ATTIC
WOOD
2x @24" O.C.
R-38
N/A
0.025
12
n/a
N/A
C. WALL INSULATION
01
02
03
04
05
06
07
08
09
10
1. D.
Manufacturer &Brand
Framing
Material
Framing Size &
Spacing
Insulation
Type
ESR Number
Cavity Insulation
R -value
Insulation
Depth
(inches)
Exterior Wall
Insulation
R -value
Interior Wall
Insulation
R -value
1
EXTERIOR WALLS
WOOD
2x6@16"O.0
R-21
N/A
0.065
5.5
R-21
N/A
D. MASS INSULATION
01
02
0306
07
08
I.D.
Manufacturer & Brand
Location BI
IL� +T ces`E E e ih pe/
/i 1' D in es
Insulation Type
Exterior Insulation
R value
Interior Insulation
R -value
N/A`
OR CONSTRU
IDATE
CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CFC.CF9R-GI T-nr-F /Revfecrl nA11A%
CERTIFICATE OF INSTALLATION v CF2R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 3 of 15)
-Enforcement
Project Name Drew Welk and Aya Hamilton Interior Remodel
City of La Quinta Permit Number:
Dwelling Address: 80861 Via Savona - - -
c"Y La Quinta Zip Code 92253
E. RAISED FLOOR INSULATION
01
02
03
04
05
06
07
08
09
10
1. D.
Manufacturer & Brand
Framing
Material
Framing Size &
Spacing
Insulation
Type
ESR Number
Cavity
Insulation
R -value
In$ulation
Depth
(inches)
Exterior Floor
Insulation
R -value
Interior Floor
Insulation
R -value
N/A
F. SLAB FLOOR/PERIMETER INSULATION
01
02
03
04
05
06
07
08
1. D,
Manufacturer & Brand
Floor Type
Insulation Type
Insulation
Depth (inches)
Insulation
R -Value
Vertical Insulation
Length (inches)
Horizontal Insulation
Length (feet)
N/A
I C'TY OF LA QU11VT,q
BUILDING 8& SAFE
ROVED
OR CONSTRUCTION
DATE
---_ABY
CA Building Energy Efficiency Standards - 2013 Residential Compliance
June 2014
STATE OF CALIFORNIA ;
Pl escriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CF2R-ALT-05-E (Revised 06/141 rel Wnawn CAICDriv rneaneiemnni
_.._.. _......._.._.._. __.......--'—•-
CERTIFICATE OF INSTALLATION CF2R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 4 of 15)
Project Name: Drew Welk and Aya Hamilton Interior Remodel Enforcement Age"`Y: City of La Quinta Permit Number:
Dwelling Address: 80861 Via Savona - - C" La Quinta Z1p Code 92253
Roofing and Radiant Barrier
G. RADIANT BARRIER
01
Brand Name and product number
N/A
02
Installation Type
07
rC)3
Total Attic Area (ft)
CRRC Product IDI
Number
H. REQUIRED VENT AREA
01
Combined NFA of installed upper and lower vents (in2)N/A
03
02
Minimum required combined NFA of upper and lower vents (int)
07
03
NFA of installed upper vents (inZ)
CRRC Product IDI
Number
04
Minimum required NFA of upper vents (in2)
Aged Solar
Reflectance
I. ROOFING PRODUCTS (COOL ROOF) INSTALLATION INFORMATION
01
02
03
04 05
06
07
08
Roof Pitch
CRRC Product IDI
Number
Product Type'ICSol
RL�g d Ic a e nitia o ar
R ane
Aged Solar
Reflectance
Thermal Emittance
SRI
BUILDING & SAFETY DEPT.
APP D
FOR CQNqTPII If-TIQDl
T
DATE BY
CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CF2R-ALT-05-E (Ravispd 06/141
CERTIFICATE OF INSTALLATION v CF2R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 5 of 15)
Project Name: Drew Welk and Aya Hamilton Interior Remodel EnPorcffAge"`Y: City of La Quinta
Perm it Number:
Dwelling Address; 80861 Via Savona city La Quinta
Zip Code 92253
J. RADIANT BARRIER AND ATTIC VENTILATION — ADDITIONAL REQUIREMENTS
Radiant Barrier
01
Radiant barrier must be installed on all vertical surfaces in the attic including gable ends.
02
The emittance of the radiant barrier shall be less than or equal to 0.05 as tested with ASTM C1371, or E408.
03
The product shall meet all requirements for California certified insulation materials [radiant barriers] of the Department of Consumer Affairs, Bureau of Home Furnishings and Thermal
Insulation, as specified by CCR, Title 24, Part 12, Chapter 12-13, Standards for Insulating Material
04
When determining the Total Attic Area, the area over unconditioned spaces such as the garage is included when the attic spaces are connected.
Lower Vents
05 1 Lower vents are within one foot of the eave.
Upper Vents
06 1 upper vents are within three feet of the ridge
Vent Area
07
The NFA of upper vents must be within required NFA range of upper vents
Note: per Exception to R806.2 of the CBC Title 24, Part2, Vol.2.5, if the net free ventilating area is less than 1:150, then the upper ventilation must be at least 40% and no more than 50%.
Part 2 contains additional requirements that must be met if the area is less than 1:150.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
K. ROOFING PRODUCTS (COOL ROOF) — ADDITIONAL REQUIREMENTS
01
Any roof area covered by building integrated photovoltaic panels and solar thermal panels are exempt from the above Cool Roof requirements.
02
Liquid field applied coatings must comply with installation criter� i�°rom s
03
Mass roof 25 Ib ftZ or greater: Mass roofs are not required to have,.a,cp I roo n i e li 11�s��fie minimum performance requirements.
I t5 U
The responsible person's signature on this compliance document affli ms that tl I b re r t sTtabl have been met.
I FOR CONS RUCTION
DATE -_BY
CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CF2R-ALT-05-E Revised 06/14 CA I-- A E
CERTIFICATE OF INSTALLATION
L I NERGY COMMISSION
CF2R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
(Page 6 of 15)
Project Name: Drew Welk and Aya Hamilton Interior Remodel
Enforcement Agency: City of La Quinta
Permit Number:
OwellingAddress: 80861 Via Savona
`I" La Quinta
Zip Code 92253
Fenestration
L. FENESTRATION/GLAZING
Includes all Windows, Skylights, Greenhouse/Bay Windows, and Glazed Doors
01
02
03
04
05
06
07
08
09
10
11
Tag/ID
Manufacturer/
Brand
Fenestration
Area (ft)
Orientation
Chromogenic
U -factor
SHGC
Source of
U -factor
and SHGC
Fenestration
Type
Exterior Shading
Devices
(Describe)
Comments/Special Features
G1
WINDOW
9
EAST
NO
0.32
0.25
NFCR
FIXED
Insect Screei
1
DOUBLE DOOR
56
NORTH
NO
0.32
0.25
NFCR
DOOR
2
SINGLE DOOR
20
EAST
NO
0.32
0.25
NFRC
DOOR
A; Ill
YOFL
v11-UIIVU &44GcT.. _ I
M. FENESTRATION/GLAZING - ADDITIONAL REQUIREMENTS®VE
Lj
01 For existing buildings the U -factor and SHGC values should be tnV
same or better a ifs ergy C mmission prescriptive requirements.
02 Temporary labels should not be removed until verified by the b it
g.' Spector.
03 The fenestration product manufacturer's installation specificati Sha ��d v�`�n installing these p oducts. The space between the fenestration product and
rough opening shall be completely filled with insulation. If batt insulation is use ze lase properly around the fenestration product.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table-E—avielbeen met.
CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CF2R-ALT-05-E Revised 06/14 CALIFORNIA ENERGY CO
MMISSION
CERTIFICATE OF INSTALLATION CF2R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 7 of 15)
'`ojectNome: Drew Welk and A a Hamilton Interior Remodel
Y
Enforcement Agency: permttNumber:
City of La Quinta
Dwelling Address:
80861 Via Savona
c" La Quinta Zip Code 92253
Mechanical and Plumbi
N. SPACE CONDITIONING (SC) SYSTEMS — HEATING/COOLING (Prescriptive section 150.2(b))
Alterations to Space Conditioning Systems shall be exempt from HERS verification requirements as prerequisite for use of the CF1R-ALT-05 and CF2R- ALT -05 Compliance Documents. If new space
conditioning systems are installed or existing systems are altered and are not exempt from HERS verification, then a CF1R-ALT-01 shall be completed and registered with a HERS Provider Data
Registry. In each row below for each dwelling unit in the building, check the box that indicates the exemption from HERS verification compliance:
❑ a: space conditioning system was not altered;
❑ b: less than 40 ft of ducts were added or replaced;
❑ c: (exempt from duct leakage testing) if: the existing duct system was insulated with asbestos;
❑ d: (exempt from duct leakage testing) if: the existing duct system was previously tested and passed by a HERS Rater.
01
02
03
04
Dwelling Unit Name
SC System Identification or Name
SC System Location or Area Served
Exemption from HERS Verification
0 0 0 11
0 0 13 0
0 0 0 11
0 0 0 0
0 0 0 0
0 0 0 11
0 0 13 0
0 0 11 11
CITY 0g: 1
0 11 0 0
GU!� O!�,'G & SA
-E FPT
11a 11b 11c 13d
i—%HP
VED
13 0 0 0
UU ON
i
0 0 ❑c 0
�aTE
❑a 0 0 11
CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014
STATE OF CALIFORNIA ;
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CFC-CF2R-ALT-05-F Mnkart nA/141
CERTIFICATE OF INSTALLATION CF2R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 8 of 15)
project Name: Drew Welk and Aya Hamilton Interior Remodel Enforcement Agency: City of La Quinta °ermIt Number:
Dwelling Address: 80861 Via Savona c"y La Quinta 'Tip Code 92253
O. INSTALLED WATER HEATING SYSTEMS (Section 150.2(b)1G)
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Dwelling Unit
Name
Water Heating
System
Y
Identification or
Name
Water Heating
System Location
or Area Served
Water
Heating
System
Type
Water
Heater
Type
# of
Water
Heaters
In System
Water
Heater
Storage
Volume
(gal)
Fuel Type
Rated
Input
Type
Rated
Input
Value
Heating
Efficiency
Type
Heating
Efficiency
Value
Standby
Loss I%)
Exterior
Insul.
R -Value
Back -Up
Solar
Savings
Fraction
N/A
CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CF2R-ALT-05-E Revised 06/14
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF INSTALLATION CF2R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 9 of 15)
Project Name: Drew Welk and Aya Hamilton Interior Remodel E"`°"e"'e"`A�e"`Y' City of La Quinta
Permit Number:
oweni"gnadreu:80861 Via Savona "" La Quinta
zinc°ae 92253
P. Installed Water Heater Manufacturer Information
01
Water Heating System ID or Name
N/A
02
Manufacturer
BUILDING & SAFETY. e ,
_ RUVE®
03
Model Number
CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CFR.f:F9R_GI T11ri_F /Rcvicerl r)AMAI
s
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF INSTALLATION
CF2R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
(Page 10 of 15) '
Project Name Drew Welk and Aya Hamilton Interior Remodel
Enforcement City of La Quinta
°e`"""umber:
Dwelling Address: 80861 Via Savona
I `" La Quinta
- ZIP Code 92253- -
Lighting
General Lighting Requirements
Additional new liphtine, and altered liahtine, shall comply with all applicable r
d in Section
Kitchen Lighting requirements
150.0(k)1C: The wattage of permanently installed luminaires should be determined as specified in Section 130.0(c).
150.0(k)1C: In the kitchen, Any electrical boxes finished with a blank cover count as 180 watts of low efficacy lighting.
Compliance demonstrated using Method (a) because only high efficacy luminaires have been installed in the kitchen.
Compliance demonstrated using Method (b). At least 50% of the installed watts from permanently installed high efficacy. Total A 2 Total B in Installed Wattage Calculation Table (below)
Compliance demonstrated with additional low efficacy wattage allowance of EXCEPTION to 150(k)3
EXCEPTION to 150.0(k)3: Additional low efficacy watts may be allowed when all luminaires in the kitchen are controlled by a vacancy sensor or dimmers, and
1. See 150.0(k)2A where high efficacy and low efficacy luminaires must be separately controlled.
2. See 150.0(k)2G where EMCS may be used as a dimmer; Section 150.0(k)2H where EMCS may be used as a vacancy sensor; or, 150.0(k)21 where multi -scene programmable controller may be used
as a dimmer.
NOTES: Compliance demonstrated using Method (c). Kitchen lighting qualifies for additional low efficacy lighting and as demonstrated in Installed Wattage Calculation Table in Method (b) (above)
in addition to Additional Low Efficacy Wattage Calculation Table (below).
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
VY OF LA QUINTA
BUILDING & SAFETY DEPT,
Fo Pr OVCLJ
I CONSTRUCTION
• - I DATE .
��BY
CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CF2R-ALT-05-E (Revised 06/141
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF INSTALLATION CF2R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 11 of 15)
Prosect Name: Drew Welk and Aya Hamilton Interior Remodel
Enforcement Agency: City of La Quinta -
Permit Number:
Dwelling Address: 80861 Via Savona _
"" La Quinta -
Zip Code
92253
Q. Installed Kitchen Lighting Compliance
In each row below for each dwelling unit in the building, check the box that indicates the method of compliance. If required by the enforcement agency, provide a Kitchen Lighting Requirements
Worksheet for each kitchen in the dwelling unit that complies using method b or c.
❑ Method A: Compliance demonstrated using Method (a) - only high efficacy luminaires have been installed in the kitchen.
❑ Method B: At least 509 of installed watts are from permanently installed high efficacy lighting
❑ Method C: Installation qualifies for additional low efficacy lighting allotment
❑ N/A: No kitchen lighting is installed
01
02
03
04
05
Dwelling Unit Name
Kitchen Lighting Compliance Method
Total High Efficacy
(Method B)
Total Low Efficacy
(Method B)
Total Additional Low Efficacy
(Method C)
11 0 0 ❑N/A
13 13 13 ❑N/A
0 0 0 ❑N/A
0 0 0 ❑N/A
0 13 0 ❑N/A
0 0 0 1:1 N/A
11 0 11 ❑N/A
11 0 0 ❑N/A
0 0 0 ❑N/A
0 0 11 ❑N/i
0 0 13 ❑N/A
QUINTA
B 12
'P
❑a 0 ❑c ❑N/'P
'A�P 9
13a ❑ b 13c 11N/A
OP CONSTRUCTION
0 El 0 ❑N AQ
TE BY
0 0 0 ❑N/A
CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
=21R -ALT -05-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION
TIFICATE OF INSTALLATION CF2R-ALT-05-
criptive Residential Alterations That Do Not Require HERS Field Verification (Page 12 of 1!
Name: Drew Welk and Aya Hamilton Interior Remodel .. Enforcement Agency: City of La Quinta°ef"itNumb":
gAddress: 80861 Via Savona - "" La Quinta - ZIP Code 92253
Kitchen Lighting Requirements Worksheet
Dwelling Unit Name:
This Table is applicable only if Kitchen Lighting using Method (b) or (c) is selected in Table Q
Method b) Total Wattage Calculation
see footnote
Luminaire (Fixture)
High . Low �°
Efficacy Efficacy j I o i ®�o f c
Total Low Efficacy
Watts Allowed
Total
Watts
High Efficacy Low Efficacy
Luminaire Type Watts Watts
Quantity
High
Efficacy
Low
Efficacy
x
=
x
=
x
=
x
=
x
—
x
=
Complies with method (b) if Total A > Total B
A
> B
Method (c) Total Additional Low Efficacy Wattage Calculation
see footnote
Watts from Method b Additional
High . Low �°
Efficacy Efficacy j I o i ®�o f c
Total Low Efficacy
Watts Allowed
` i.11LDING
I
1. Insert 50 if house is:S 2.59 0 squ se is j 2,500 square feet.
DATE=6Y
CA Building Energy Efficiency Standards -,2013 Residential Compliance June 2014
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CEC-CF2R-ALT-05-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF INSTALLATION CF2R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 13 of 15)
Project Name: Drew Welk and Aya Hamilton Interior Remodel
Enforcement Agency: City of La Quinta Permit Number:
Dwelling Address: 80861 Via Savona
"" La Quinta - Zip code 92253
Pool and Spa
R. POOL AND SPA SYSTEM TYPE
01 TPool and Spa System Type
S. POOL AND SPA SYSTEMS AND EQUIPMENT REQUIREMENTS (SECTION 110.4(a) and 110.5)
01 Heater has a thermal efficiency that complies with the Appliance Efficiency Regulations.
02 A readily accessible on-off switch is mounted on the outside of the heater, which allows the heater to be shut off without the user adjusting the thermostat setting.
03 A weatherproof plate or card containing instructions for the energy-efficient operation of the pool or spa heater is permanently mounted.
04 No electric resistance heating except for listed package units that have fully insulated enclosures and tight fitting covers that are insulated to at least R-6. Or if documentation is provided
that at least 60 % of the annual heating energy is from site solar energy or recovered energy.
05 Heating system has no pilot light.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
T. POOL AND SPA SYSTEM INSTALLATION REQUIREMENTS (SECTION 110.4(b))
01 To allow for the future addition of solar heating equipment, at least 36" of pipe is installed between the filter and heater, or dedicated suction and return lines are installed, or built-in or
built-up connections for future solar heating are provided.
02 A cover is provided for outdoor pools or spas that have a heat pump or gas heater.
03 Pool system has directional inlets to adequately mix the pool water
04 Pool system has a time switch that allows the pump to be set or programmed to run during off-peak periods only
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
CITY OF LA QUINTA
13UILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DAT BY
CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
r:FG('F9R-AI T11F_F IP—A-4 !)AMAX
El
CERTIFICATE OF INSTALLATION v CF2R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 14 of 15)
Project Name: Drew Welk and Aya Hamilton Interior Remodel
Enforcement Apelq: City of La Quinta
Permit Number:
Dwelling Address: 80861 Via Savona
`I" La Quinta
Zip Code 92253
U. POOL PUMP SIZING AND FLOW RATE SPECIFICATION (SECTION 150.0(p))
01
The pool pump specified is listed in the CEC database of certified pool pumps.
02
The pool pump flow rate shall not exceed the maximum pump flow rate calculated based on pool sizing in the table below. The return pipe diameter, suction pipe diameter, and filter area
shall be at least as large as the required minimums shown in the table.
Alternatively, a flow calculation or flow test result shall be provided to demonstrate that the pump flow rate is less than 6 hour filtration turnover, and the return pipe flow rate
does not exceed 8 feet per second and that the suction pipe flow rate does not exceed 6 feet per second.
03
An alternative compliance calculation or a flow test result is provided for this pool or spa
use (must attach flow calculation or flow test result to this form)
04
The pump is capable of operating at 2 or more speeds (not applicable if pump is less than 1 horsepower).
05
Each auxiliary pool load is served by either a separate pump, or the system is served by a multi -speed pump.
06
Volume of pool (gallons):
07
Filter Type (Cartridge, Sand, DE):
08a
Required Min Return Pipe Diameter (inches)
08b
Required Min Suction Pipe Diameter (inches)
08c
Required Min Filter Area (ft)
08d
Required Max Pump Flow (gpm)
09
Return Pipe Diameter (inches).
10
Suction Pipe Diameter (inches).
11
Filter Surface Area (ft).
12
Max Pump Flow Rate (gallons per minute).
13
Measured flow rate return line (feet per second)
14
Measured flow rate suction line (feet per second)
15
Compliance statement U. 03 = Yes, U. 13!5 U. 08, and U. 14 5 U. 06 ❑ Yes ❑ No
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met.
V. POOL SYSTEM PIPING (Section 150.0(p)2)
01 The suction side pipe is straight for at least 4 pipe diameters before n h p S tah+vp1IAwtGv.Ske r quired straight run lengths for various pipe sizes).
02 All elbows are sweep elbows, or an elbow type that has a pressu�e dro t a is s ha p
of a straight pipe with a length of 30 pipe diameters. I BeJILDING & SAFFTV nr:pr
The responsible person's signature on this compliance document affirm; that all gDplt�Wr&—qujfmMrbtq+ this table h ve been met.
W. POOL FILTERS AND VALVES (Section 150.0(p)3 and 4) 1- . —" "'' "'v f f%JIM
01 If a filter is used in a pool intended for public use: The size of th f' t is at least the size specified in NSF/ANSI 5
02 If a backwash valve is used: The diameter of the backwash valve is at le 'ameter of the retur pipe, whichever is greater.
The responsible person's signature on this compliance document affirms that a app ica—bl re ve been met.
CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014
. STAIE OF CALIFORNIA ;
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
CFC-CF9R-AI Td18-F 114—i—1 nA/14t ('Al 11:0PMin aWrPrV ennnnnlcclnK]
CERTIFICATE OF INSTALLATION CF2R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification (Page 15 of 15)
Pr°Ject Name: Drew Welk and Aya Hamilton Interior Remodel Enforcement Agency: City of La Quinta Permit Number:
Dwelling Address: 80861 Via Savona °" La Quinta - Zip Code 92253
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
ALBERTO DAZA
ALBERTO DAZA
Documentation Author Company Name:
Date signed:
DA.ZARCHSTUDIO
07/12/16
Address:
CEA/HERS Certification Identification (if applicable):
P.0.130X5083
City/State/Zip:
Phone:
LA QUINTA CA.92248
7602853793
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Installation is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features,
materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement (responsible
builder/installer), otherwise I am an authorized representative of the responsible builder/installer.
3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and
regulations, and the installation conforms to the requirements given on the plans and specifications approved by the enforcement agency.
4. 1 reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this
Certificate of Installation, and I have ensured that the requirements that apply to the construction or installation have been met.
5. 1 will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the
enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides
to the building owner at occupancy.
Responsible Builder/Installer Name:
Responsible Builder/Installer Signature:
David Jacobsen Design
Monarch Homes Desert Division
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
Position With Company (Title):
OWNER
Address:
CSLB License:
49950 Jefferson street suite #130-134
457228
City/state/Zip:
Phone
Date Signed:
Indio Ca 92201
7604138863
07/12/16
For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300.
CITY OF LA QUINTA
BUILDING & SAFETY
PT,
FOR1PPF?0VCD
CONSTRUCT►nnf
SATE
CA Building Energy Efficiency Standards - 2013 Residential Compliance--��_B�r June 2014