Loading...
12-0945 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T4h t44Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT 4pplicationNumbe^y12=0000094,5 Owner: Property -Address: 5245 A SAVONA STEVEN & SUSAN FISHOFF APN: 772-410-999-5 -298943- 2648 FEATHERWOOD ST Application description: DWELLING - SINGLE FAMILY DETACHED WESTLAKE VILLAGE, CA 91362 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 596058 \ VOICE (760) _ 12 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/29/12 Contractor: Applicant: Architect or Engineer: SUNROSE CORPORATION 40101 MONTEREY AVE STE B1 - RANCHO MIRAGE, CA 92270 (760)773-6633 J, - Lic. No.: 5.33670 OCT 3O 2�/z - - - CF NAN E QUI TA LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 Icommencing with I hereby affirm under penalty of perjury one of the following declarations: ection 7000) of Divisio 3 of the Business and Professionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided icense Class: B License No.: 533670 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. J1at./?/a-40ao,/Contr tor: _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation OWN BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier STATE FUND Policy Number 1948056-2012 following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, it I should become subject to the workers' compensation provisions of Section License Law (Chapter.9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the Labor Code, hall forthwiEh mply ith those rovisions. _ that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by � any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: - (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WO KERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.)• whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_ 1 I am exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and county ordinances and state laws relating to buildin construction, and hereby authorize representatives o} this/county to enter u on the above-mentioned pr perty fo inspection pur oses. /Dat ef D Signature (Applicant or A ntl: Application Number . . . . . 12-00000945 Structure Information Construction Type . . . . . TYPE V, UNPROTECTED Occupancy Type . . . DWELLG/LODGING/LONG <=10 Other struct info . . . . . CODE EDITION 2010 # BEDROOMS 5.00 FIRE SPRINKLERS YES GARAGE SQ FTG 1295.00 PATIO SQ FTG 1506.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 5790.00 ---------------------------------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE 1140.00 Permit BUILDING PERMIT Additional desc . . Permit Fee . . . . 2330.50 Plan Check Fee 1514.83 Issue Date . . . . Valuation . . . . 596058 Expiration Date . . 4/27/13 Qty Unit Charge Per Extension BASE FEE 2039.50 97.00 3.0000 ---------------------------------------------------------------------------- THOU BLDG 500,001-1,000,000 291:00 Permit ELEC-NEW RESIDENTIAL Additional desc . . Permit Fee . . . . 324.55 Plan Check Fee 81.14 Issue Date Valuation 0 Expiration Date 4/27/13 Qty Unit Charge Per Extension BASE FEE 15.00 6890.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 241.15 2670.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 53.40 1.00 15.0000 ----------=----------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/27/13 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . . . . MECHANICAL LQPERMIT Application Number . . . . . 12-00000945 Permit . . . MECHANICAL Additional desc . . Permit Fee . . . . 251.50 Plan Check Fee 62.88 Issue Date . . . . Valuation . . . . 0 Expiration Date 4/27/13 Qty Unit Charge Per Extension BASE FEE 15.00 6.00 9.0000 EA MECH FURNACE <=100K 54.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 5.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 82.50 13.00 6.5000 EA MECH VENT FAN 84.50 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 Permit PLUMBING Additional desc . . Permit Fee . . . . 291.00 Plan Check Fee 72.75 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/27/13 Qty Unit Charge Per Extension BASE FEE 15.00 34.00 6.0000 EA PLB FIXTURE 204.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 20.00 .7500 EA PLB GAS PIPE >=5 15.00 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 6890 SF 2 STORY SFD. TYPE V -B W/ FIRE SPRINKLERS. R-3 OCCUPANCY. 2010 CODES. 2008 DIF. **PERMIT DOES NOT INCLUDE BLOCK WALLS, FENCES, SWIMMING POOLS, SPA, BBQ'S and DRIVEWAY APPROACH** ARCHITECT: STEPHEN V. HARREL C10507 ------------------- Other Fees -------------------------------------------------------- . . . . . . . . . BLDG STDS ADMIN (SB1473) 24.00 DIF COMMUNITY CENTERS -RES 104.00 DIF CIVIC CENTER - RES 1089.00 ENERGY REVIEW FEE 151.48 DIF FIRE PROTECTION -RES 612.00 DIF LIBRARIES - RES 334.00 MULTI -SPECIES (MSHCP) FEE 1254.00 DIF PARK MAINT FAC - RES 51.00 DIF PARKS/REC - RES 1773.00 LQPERMIT Application Number . . . . . 12-00000945 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STRONG MOTION (SMI) - RES 59.61 DIF STREET MAINT FAC -RES .158.00 DIF TRANSPORTATION - RES 3592.00 Fee summary Charged Permit Fee Total 3212.55 Plan Check Total 1731.60 Other Fee Total 9202.09 Grand Total 14146.24 LQPERMIT Paid Credited Due .00 .00 3212.55 1000.00 .00 731.60 .00 .00 9202.09 1000.00 .00 13146.24 Ti4 4 4 a" 17-ml4q- P.O. BOX 1504 APPLICATION ONLY Building` 78-495 CALLE TAMPICO �� ��� Address //i- c�/9-1/O�/� LA QUINTA, CALIFORNIA 92253 7lV,zc $( c�,,Wj �t�5 t�`o �•� Mailing Address ,,?—& � � ��r� moo U QST City Zip 912 Tel. uomr or vc'�c2osE �.2�' Address Ity Zip Tel. & Classif. �5 33 Lic. # Arch., Engr., ,�// ^ Designer �S%7��f1`'e'�' -G- yi A) 9,95 �-7y 107 LICENSED ONTRACTOR'S DECLARATION hereby affirm t l am licensed�md@r provisions of Chapter 9 (commencing with Section 000) of Division 3 o the Businqss and Nofessions Code, a%l my license is in full force and Oy✓NtR-BUILDER DECLARATION I hereby ffirm that I am //exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds ori mproves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinancesand state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CONST.SF_ OCC. GRP. A.P. Number -77 7 3 ?6 /60 3 Legal Description 4-0 T Project Description Sq. Ft. Size C� i d? e) New ❑ Add ❑ Estimated Valuation PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical M No. Dw. Units Alter ❑ Repair ❑ Demolition ❑ AMOUNT 117 Infrastructure 0_0040331O r d M -_ ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by:_ Validated by: Date Permit Validation: YELLOW = APPLICANT PINK = FINANCE Coaclla Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMWIND. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: The HideawayDate: October 18, 2012 Owner's Name: Steve & Susan Fishoff Phone No. 760-773-6633 Project Address: 52-455 Via Savona, LaQuinta, CA Project Description: New Single Family Dwelling APN: 777-370-003 Tract #: Type of Development: Residential xx Commercial Total Square Feet of Building Area: 6,890 Lot #'s: Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: October 18, 2012 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code Project 65995 Approval 6890 $3.20 $22048.00 Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Agreement Existing Not Subject to Fee Prior to 1/1/87 Requirement Note: Pursuant to AB 181 any room additions or enclosures of 500 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within the same school district's jurisdiction are exempt from developer fees. Certificate issued by: Laurie Howard, Secretary Signature: � o NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. M V:cfruydnes/devfees/certificate of compliance form updated 3-2007 11/2010 Susan L. Fishoff 2618 Featherwood Street West Lake Village, CA 91362 ORDER NO. -474426 ESCROW NO. 7406-474426 APN. 777-370-003 SPACE O.;?- G GRANT DEED THE UNDERSIGNED GRANTOR(s) DECLARE(s): DOCUMENTARY TRANSFER TAX is: $357.50 0 Monument Preservation Fee is: © computed on full value of property conveyed, or 0 computed on full value less value of liens or encumbrances remaining at ti 0 Unincorporated area: 10 City of La Quinta, and FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowle( Robert Wesley Burns, Trustee of the Robert Wesley Burns Revocable T "'This document was electronically submitted to the County of Riverside for recording— Receipted by: LJONES E THIS LINE FOR RECORDER'S USE CITY TAX of sale. I, dated January 23, 2U07 hereby GRANT(S) to Steven FisholI'and Susan L. Fishoff , husband and wife as joint tenants the following described real property in the City of La Quina, County of R LEGAL DESCRIPTION ON)EXHIBIT A DATE: June 12, 2012 STATE OF C*HfORNTA -axAm COUNTY OF �Y�I On2ae l 24 11 before me, Public, personally appeared a No State of California The Robert Wesley Burns Revocable Tru at A4 Japuiary 23, 2007 Wesley Burns. Trustee HIDEAWAY OWNERS ASSOCIATION October 17, 2012 Mr. and Mrs. Steven Fishoff 2648 Featherwood Street Westlake Village, CA 91362 RE: Lot 5/6C at 52455 Via Savona Final Design Review #3 Dear Mr. and Mrs. Fishoff, The Hideaway Design Review Committee (DRC) .reviewed and approved the revised Final Construction Documents for your home on Via Savona. The project may start construction after a Pre -Construction Meeting is held in the field with Mike Tuvell on Friday, October 1.8, 2012. Please consult directly with Gerry Tarsitano regarding any remaining improvements that may impact the existing grades and/or planting beyond the rear Transition Area line. > You may reach Brook Marshall at (760) 219-8057 or by email at Brook@dc.rr.com with any questions regarding this review. Sincerely, Hideaway Design Review Committee cc: Sedona Homes JHsl10ff@'10l.c0m Gerry Tars itano DRC File 80955 Avenue 52 La Quinta, CA 92253 P: 760 393-5210 F: 760 398-5788 PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALI M ESA CANYON LAKE COACHELLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO LAKE ELSINORE LA QUINTA MENIFEE MORENO VALLEY PALM DESERT PERRIS RANCHO MIRAGE RUBIDOUx CSD SAN JACINTO TEMECULA WILDOMAR BOARD OF SUPERVISORS: BOB BUSTER DISTRICT 1 JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 MARION ASHLEY DISTRICT 5 RIVERSIDE COUNTY FIRE DEPARTMENT IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 92211-4131 • Phone (760) 863-8886 • Fax (760) 863-7072 www.rvcfire.org November 13, 2012 Residential Fire Systems Re: Residential Fire Sprinkler Plan Review LQ -12 -RS -057 52-455 Via Savona La Quinta, CA The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department Planning & Engineering personnel and are approved with the following conditions: A minimum of three spare fire sprinklers of each type and temperature rating along with a _ sprinkler wrench should be located in a spare head cabinet at the system riser or other approved location. Permanently marked identification signs shall be attached to all control valves. The completed Contractor's Material and Test Certificate for Aboveground Piping shall be provided to the fire inspector prior to a final inspection. A typical certificate is shown in Figure 10.10.1 NFPA13. A warning sign, with minimum'/ inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protections specialist. DO NOT remove this sign. The following inspections/tests are required to be witnessed by the Fire Department Planning Division staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. (b) Final inspection. The Fire Department job card, approved plans and conditions letter must be at the job site or NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection date. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Applicant/installer shall be responsible to contact the Fire Department to schedule. inspection. Sincerely, Jas Stu ble Fire Safety Specialist Northbrook oivlslon 333 Ptingsten Road Underwriters Northbrook, 4L 60062-2096 USA Laboratories Inc - T. www.ui.com te1:1 847 272 B800 tax: 1 847 272 8129 Customer service: 1877 854 3577 Vol 1 Issued 2005-03-10 File MH30042 Revised FOLLOW-UP SERVICE PROCEDURE (TYPE L) SOLID FUEL -BURNING APPLIANCE ACCESSORIES (DGOU) Manufacturer: AMERICAN CHIMNEY SHROUD INC (127145-001) 26401 VIA DEL ANZA SAN JUAN CAPISTRANO CA 92675 Applicant: SAME AS MANUFACTURER (127145-001) Classified Company: SAME AS MANUFACTURER (127145-001) the marking specified by This Procedure authorizes the above Manufacturer to use Underwriters Laboratories Inc. only on products Servicecovered Agreementis Procedure, in accordance with the applicable Follow -Up The prescribed Mark or Marking shall be used only at the above manufacturing location on such products which comply with this Procedure and any other applicable requirements. other The Procedure contains information for the use of the above nwriamed Manufacturer an ies nc. and is not to representatives of Under thetManufaturexxwith =the understanding beused isrnotyto pure be copied, either wholly or in part, and that it will be returned to Underwriters Laboratories Inc. upon request. This PROCEDURE, and any subsequent revisions, is the property of UNDERWRITERS LABORATORIES INC. and is not transferable. UNDERWRITERS LABORATORIES INC. �W x, N A.W. Schaefer Sr. Vice President Global Services and Administration IAF v- ;IVEI� SEP 2 6 2012 An Independent organization working for a safer world with Integrity, precision and knowledge. U el _ Cyt AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the Product covered describe below herein when made in accordance with the authorized Listing Report, including Manufacturing/Machining Specifications, and under conditions set forth in the Certification Agreement and Listing Report, including Manufacturing/Machining specifications. This authorization also applies to the Multiple Listee model(s) identified on the correlation page of the Listing Report. Applicant: Industrial Chimney Company (1CC) 400, J.F. Kennedy St -Jerome; QC J7Y 4137 Contact: Name: Andre Bibaud Phone: (450) 565-6336 Manufacturer: American Chimney Shroud 26401 Via de Anza San Juan Capistrano, CA 92675 Party Authorized Same as Manufacturer To Apply Mark: Report Issuing Office: Intertek ETL Semko, 1829, 32nd Avenue, Lachine, Quebec Canada H.8T'3J1 Report No.: 3091753 Product Covered: Custom Shroud, Model RIS -COMPONENT Description: Decorative shroud surrounding the standard termination cap.. Standard(s): LIL 103 - 08/23/2001 Factory -Built Chimneys for Residential Type and Building Heating Appliances -Tenth Edition; Reprinted with Revisions Through and Including December 9,2005 This document is the property of Intertek Testing Services and is not transferable. Only the Applicant may reproduce this document. The certification mark(s) may be applied only at the. above noted location of the Party Authorized to Apply Mark(s). This document supecsedes all previous Authorizations to Mark for the noted Report number. Authorized by: Date: � &1 Bob Davison, Certification Manager, Toronto Center Intertek Testing Services NA Inc. 3210 American Drive, Mississauga, ON L4V 1133 Canada Phone 905-678-7820 Fax 905-678-7131 .SD 16.3.10b(9/10/02) Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2012 Electronically Signed at CalCERTS.com by Lance Alacano (Sunrose Corporation) 9/26/2012 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Fishoff Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/25/2012 Project Address 52-455 Via Savona, The Hideaway La Qi, California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,980 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 5,686 Radiant Barrier New Wall Wood Framed R-21 6,902 New Door Opaque Door None 120 New Slab Unheated Slab -on -Grade None - 6' P New & b I'll ION CO FENESTRATION U- w1 , %'--Exterior Orientation Area Factor SHGC Overhan Sidefi s S Status Left (SE) 48.0 0.390 0.37 none Bug Screen, U New Right (NM 100.0 0.3900.37 none q tenon _.-�- BugScreen New T Rear (SM11- V 86.0 )f 0.390 V 0.37 none,' J none i• Bug Screen V New Rear (SIM ,4204.0. ! ;( 0.390 0.37 5.01 done Bug Screen F�� � New Front (NE) . 343.1 , 3 0.390 _ 0!37 none, Y none ', Bug Screen e-eol- ) yNew Front (NE)1.8,,,'.`� 0.390 .x`0.37 "!none' �none,,W , Bug'Screen Rear (SIM 264.0 0.390 0.37 15.0 none Bug Screen New Front (NE) 12.9 0.390 0.37 none none Bug Screen New Left (SE) 88.0 0.390 0.37 4.0 none Bug Screen New Left (SE) 36.0 0.390 0.37 none none Bug Screen New Left (SE) 119.3 0.390 0.37 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 2 Small Gas 75 0.65 All Pipes Ins - v; Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Pae 1 of 10 Reg: 212-N0049881B-000000000-0000 Registration Date/Time: 2012/09/10 11:26:33 it Prom Ca10ERTS, imc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2012 Electronically Signed at Ca10ERTS.com by Lance Alacano (Sunrose Corporation) 9/26/2012 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Fishoff Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/25/2012 Project Address 52-455 Via Savona, The Hideaway La Qt, California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,980 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. IZI Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity ft) Features see Part 2 of 5 Status -'t FENESTRATION °` `.U- Exterior Orientation...:;Area Factor SHGC Overhang Sidefins Shades Status Rear (SW 62.0 0.390 0.37 10.0 none Bug Screen New Rear..(SVO 80.00 390 0 37 none # ; .. none Bug Screener _ New Right (NVI�;" ; 107.0 0 390 0 37 none '. j ;none „Bug Screeb r New Right (NVV) f 80 0 0 390; 0 37„±none .` none _ . .Bug Screen New ,t :.:. . <.. Left 037 none `; ; , ;'none Bug Screens }Y� ;%" New' h i.% c HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 15.2 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number.' 6712 Runcode: 2012-09-25716:19:52 ID: Page 2 of 10 Reg: 212-NO04988IB-000000000-0000 Registration Date/Time: 2012/09/10 11:26:33 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 9/25/2012 Electronically Signed at CalCERTS.com by Lance Alacano (Sunrose Corporation) 9/26/2012 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Fishoff Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/25/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix R43.3 must be met. HIGH MASS Design -Verify Thermal Mass: 1,091.0 ft' Covered Slab Floor, 3.500" thick at Zone 1 Bedrooms HIGH MASS Design - Verify Thermal Mass: 361.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 1 Bedrooms The HVAC System HVAC 2 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 497.0 ft2 Covered Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 239.0 ft2 Exposed Slab Floor, 3.500" thick at Master Suite The HVAC System HVAC 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design -Verify Thermal Mass: 116.0 ft2 Covered Slab Floor, 3.500" thick at Great HIGH MASS Design - Verify Thermal Mass: 942.0 ft' Exposed Slab Floor, 3.500" thick at Great HIGH MASS Design - Verify Thermal Mass: 1,184.0 ft' Covered Slab Floor, 3.500" thick at Kitchen/Dining HIGH MASS Design - Verify Thermal Mass: 1,456.0 ft' Exposed Slab Floor, 3.500" thick at Kitchen/Dining The Roof R-38 Roof(R.38.204.16) includes credit for a Radiant Barrierthat is Continuous meeting eligibility and installation criteria as specified in Residential A'endix RA4.2.2. HERS,REQUI�RED VERIFICATION .._� Items iri thiissection,require field testing nd/or verification by a certified'HERS Ratei The�inspector-must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 5 Ton includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 3 Ton includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 4 Ton includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 3.5Ton includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ener Pro 5.1 by EnerqySoft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Page 3 of 10 Reg: 212-N0049881B-000000000-0000 Registration Date/Time: 2012/09/10 11:26:33 HERS Provider: Ca10ERTS, Inc Ik: ' Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2012 Electronicallv Sianed at CaICERTS.com by Lance Alacano (Sunrose Corporation) 9/26/2012 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Fishoff Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1912512012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERSREQU,IRsEDVsERIFICATION "'45 ii �, (J" '+ Y 1 f +`f e§` s.a. c .S'ia'S , Items inA is -810c field testing and/or verlflcat)on by a certifietl HERS Rafer Th&i spector�must receive a �.x., com leted CF,:.4R form `for each of,the rrieasures.11ste telow for final to'be' even The Cooling System'Carrier 5 Ton includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct ^l Condenser. ;_ x, The HVAC'system HVAC $ incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 5 incorpoiatesHERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified cntena EnemvPro 5.1 by Ener Soft User Number: 6712 Run Code: 2012-09-25716:19:52 ID: Page 4 of 10 Reg: 212-N0049881B-000000000-0000 Registration Date/Time: 2012/09/10 11:26:33 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 9/25/2012 Electronically Signed at CalCERTS.com by Lance Alacano (Sunrose Corporation) 9/26/2012 M PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Fishoff Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 9/25/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 5.71 5.93 -0.22 Space Cooling 55.40 47.28 8.12 Fans 11.10 14.00 -2.90 Domestic Hot Water 4.92 5.33 -0.41 Pumps 0.00 0.00 0.00 Totals 77.13 72.55 4.58 Percent Better Than Standard: 5.9% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NE) 28 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (NE) 2,205 358 Fuel Available at Site: Natural Gas (SE) 2,160 309 Raised Floor Area: 0 (SlM 1,912 696 Slab on Grade Area: 5,886 (NM 2,375 287 Average Ceiling Height: 12.2 Roof 5,686 0 Fenestration Average U -Factor: 0.39 TOTAL: 1,650 Average SHGC: 0.37 Fenestration/CFA Ratio: 23.16% REMARKS 77 7. t fi STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 9/15/2012 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Stephen V. Harrel, Architect Address 141 N. Duesenberg Drive, Suite 14 Name Stephen V. Harrell City/State/Zip Westlake Village, CA 91362 Phone (805) 379-1071 Signed License # Date EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Page 5 of 10 Reg: 212-N0049881B-000000000-0000 Registration Date/Time: 2012/09/10 11:26:33 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2012 Electronically Signed at CalCERTS.com by Lance Alacano (Sunrose Corporation) 9/26/2012 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Fishoff Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1912512012 OPAQUE SURFACE DETAILS Surface Type Area U Insulation Joint Appendix Factor Cavity7Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,452 0.026 R-38 270 0 New 4.2.1-A9 Zone 1 Bedrooms Wall 416 0.069 R-21 58 90 New 4.3.1-A6 Zone 1 Bedrooms Door 24 0.500 None 58 90 New 4.5.1-A4 Zone 1 Bedrooms Wall 440 0.069 R-21 148 90 New 4.3.1-A6 Zone 1 Bedrooms Wall 30 0.069 R-21 238 90 New 4.3.1-A6 Zone 1 Bedrooms Wall 260 0.069 R-21 328 90 New 4.3.1-A6 Zone 1 Bedrooms Slab 1,091 0.730 None 0 180 New 4.4.7-A1 Zone 1 Bedrooms Slab 361 0.730 None 0 180 New 4.4.7-A1 Zone 1 Bedrooms Roof 736 0.026 R-38 270 0 New 4.2.1-A9 Zone 2 Master Suite Wall 73 0.069 R-21 118 90 New 4.3.1-A6 Zone 2 Master Suite Wall 244 0.069 R-21 148 90 New 4.3.1-A6 Zone 2 Master Suite Wall 292 0.069 R-21 208 90 New 4.3.1-A6 Zone 2 Master Suite Wall 319 0.069 R-21 298 90 New 4.3.1-A6 Zone 2 Master Suite Slab 497 0.730 None0 180 New 4.4.7-A1 Zone 2 Master Suite Slab 239 0.730 None 0 180 New 4.4.7-A1 Zone 2 Master Suite Roof 1,058 0.026,R-38 270 0 New 14.2.1-A9 JZone 3 Great FENESTRATION SURFACE DETAILS ID Type I Area LI -Factor' SHGC4 Azm Status Glazing Type Location/Comments 1 Window 8.0 0.390 NFRC 0.37 NFRC 148 New Sierra Pacific Windows & Doors Zone 1 Bedrooms 2. Window 4.0 0.390 NFRC 0.37 NFRC 148 New Sierra Pacific Windows & Doors Zone 1 Bedrooms 3 Window- 4.0 0.390 NFRC 0.37 NFRC 148 New Sierra Pacific Windows & Doors Zone 1 Bedrooms 4 Window 4.0 0.390 NFRC 0.37 NFRC 148 New Sierra Pacific Windows & Doors Zone 1 Bedrooms 5 Window..,,,,,;_ ._; 8.0 0.390 NFRC - ,-0:37, NFRC_-,. ___,__14:8 New..„._ :Sierra;P.acific.Windows &_Doors. Zone 1 Bedrooms 6 Window" V8.0 0.390 -NFRCd . 0" 0.37 NFRC 148 New Sierra Pacific Windows'&'Doors Zone 1 Bedrooms 7 Window 4.0 0.390 NFRC C 0.37 NFRC 148 New < ; Sierra Pa ific Windows &"Doors Zone 1 Bedrooms 8 Window 30A .;0.390 NFRC 0.37 NFRC '^. mol 328 New,, -ol? Sierra Pacific Windows & Doors Zone.1 Bedrooms 9 Window 20.`0 J 0.390 NFRC i 0.37 NFRC T 328 New Sierra Pacific Windows &'Doors Zone 1,Bedrooms; ,n 10 Window 1 , 20.0, 1.0.390 NFRC 0.37 NFRC.` ;328 New.- l_ Sierra Pacific Windows & Doors Zone 1 Bedrooms 11 WindowA4 0 x„30.0 x..0:390 NFRC • '----0.37 NFRC � ".=328 New L- Sierra"Pacific Windows & Doors Zone'1'BedroornO 12 Window 8.0 0.390 NFRC 0.37 NFRC ' 148 New Sierra Pacific Windows & Doors Zone 2 Master Suite 13 Window8.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 2 Master Suite 14 Window- 32.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 2 Master Suite 15 Window 120.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 2 Master Suite 16 Window 96.0 0.390 NFRC 0.37 NFRC 28 New Sierra Pacific Windows & Doors Zone 3 Great (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hanq Left Fin Ri ht Fin Len H t LExt RExt Dist Len I H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 1 0.761 10.0 12.0 5.0 0.1 5.0 5.0 16 JBug Screen 1 0.76 EnergyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: page 6 of 10 Reg: 212-N0049881B-000000000-0000 Registration Date/Time: 2012/09/10 11:26:33 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 9/25/2012 Electronically Signed at CalCERTS.com by Lance Alacano (Sunrose Corporation) 9/26/2012 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Fishoff Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9125/2012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 448 0.069 R-21 28 90 New 4.3.1-A6 Zone 3 Great Wall 92 0.069 R-21 58 90 New 4.3.1-A6 Zone 3 Great Wall 140 0.069 R-21 78 90 New 4.3.1-A6 Zone 3 Great Wall 254 0.069 R-21 2081 90 New 4.3.1-A6 Zone 3 Great Wall 120 0.069 1 R-21 328 90 New 4.3.1-A6 Zone 3 Great Slab 116 0.730 None 0 180 New 4.4.7-A1 Zone 3 Great Slab 942 0.730 None 0 180 New 4.4.7-A1 Zone 3 Great Roof 1,146 0.026 R-38 270 0 New 4.2.1-A9 Zone 3 Kit/Din Wall 110 0.069 R-21 28 90 New 4.3.1-A6 Zone 3 Kit/Din Wall 448 0.069 R-21 48 90 New 4.3.1-A6 Zone 3 Kit/Din Door 24 0.500 None 48 90 New 4.5.1-A4 Zone 3 Kit/Din Wall 118 0.069 R-21 118 90 New 4.3.1-A6 Zone 3 Kit/Din Wall 268 0.069 R-21 138 90 New 4.3.1-A6 Zone 3 Kit/Din Wall 315 0.069 R-21 208 90 New 4.3.1-A6 Zone 3 Kit/Din Wall 130 0.069 R-21 228 90 New 14.3.1-A6 JZone 3 Kit/Din Wall 416 0.069 R-21 1 2981 90 New 14.3.1-A6 JZone 3 Kit/Din FENESTRATION SURFACE DETAILS ID Type Area LI -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 7.1 0.390 NFRC 0.37 NFRC 28 New Sierra Pacific Windows & Doors Zone 3 Great 18 Window 240.0 0.390 NFRC 0.37 NFRC 28 New Sierra Pacific Windows & Doors Zone 3 Great 19 Window 1.8 0.390 NFRC 0.37 NFRC 58 New Sierra Pacific Windows & Doors Zone 3 Great 20 Window 240.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 Great 21 Window._ ,_,. .8.0 0.390 NFRC X0:37. NFRC- 48 New- Sierra, P. &_Doors Zone 3 Kit/Din 22 Window' �N 88.0 0.390 'NFRC oo 0.37 NFRC 118 New ", ' Sierra'Pacific Windows'&'Doors Zone 3 Kit/Din 23 Window `36.0 0.390 NFRC 0.37 'NFRC 118 New 4 Sierra Pacific Windows & Doors Zone 3 Kit/Din 24 Window 30.0 ".:0.390 NFRC 0.37 NFRC -4138 New �r Sierra Pacific Windows'& Doors Zone 3 Kit/Din 25 Window 12.15 .i 0.390 NFRC 0.37 NFRC V 138 New Sierra Pacific Windows &'Doors Zone 3 Kit/Din,-.ft 26 Window Af J20.01 r 0.390 NFRC 0.37 NFRC ,038 New-- I Sierra Pacific Windows & Doors Zone 3 KiUDin i 27 Windowv_ + k20.0 .,0.390 NFRC X0.37 NFRC' s M:,'138 New : 1 Sierra'Pacific Windows & Doors Zone'3 Kit/Din-'-.0+'0 28 Window 20.0 0.390 NFRC 0.37 NFRC ' 138 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 29 Window 22.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 30 Window 24.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 31 Window 60.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 KiUDin 32 Window 24.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 KiWin (1) 1.1 -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len I H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 10.0 24.0 15.0 0.1 15.0 15.0 21 Bug Screen 0.76 22 Bug Screen 0.76 8.0 11.0 4.0 0.1 4.0 4.0 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bu Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 5.5 4.0 10.0 0.1 10.0 10.0 30 Bug Screen 0.76 8.0 3.0 15.0 0.1 15.0 15.0 31 113ug Screen 1 0.76 6.0 10.0 5.0 0.1 5.0 5.0 32 Bu Screen 0.76 8.0 3.0 5.0 0.1 5.01 5.0 EnergyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2012.09-25716:19:52 ID: Page 7 of 10 Reg: 212-N0049881B-000000000-0000 Registration Date/Time: 2012/09/10 11:26:33 HERS Provider: Ca10ERTS, inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2012 Electronically Signed at CalCERTS.com by Lance Alacano (Sunrose Corporation) 9/26/2012 a CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Fishoff Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1912512012 OPAQUE SURFACE DETAILS Surface Ll- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Door 24 0.500 None 298 90 New 4.5.1-A4 Zone 3 Kit/Din Wall 332 0.069 R-21 318 90 New 4.3.1-A6 Zone 3 Kit/Din Door 24 0.500 None 318 90 New 4.5.1-A4 Zone 3 MOM Door 24 0.500 None 318 90 New 4.5.1-A4 Zone 3 Kit/Din Slab 1,184 0.730 None 0 180 New 4.4.7-A1 Zone 3 Kit/Din Slab 1,456 0.730 None 0 180 New 4.4.7-A1 Zone 3 MOM Roof 1,294 0.026 R-38 270 0 New 4.2.1-A9 Zone 3 2nd Floor Wall 50 0.069 R-21 28 90 New 4.3.1-A6 Zone 3 2nd Floor Wall 235 0.069 R-21 48 90 New 4.3.1-A6 Zone 3 2nd Floor Wall 325 0.069 R-21 78 90 1 New 4.3.1-A6 Zone 3 2nd Floor Wall 263 0.069 R-21 138 90 New 4.3.1-A6 Zone 3 2nd Floor Wall 195 0.069 R-21 208 90 New 4.3.1-A6 Zone 3 2nd Floor Wall 409 0.069 R-21 298 90 New 4.3.1-A6 Zone 3 2nd Floor Wall 160 0.069 R-21 318 90 New 4.3.1-A6 Zone 3 2nd Floor FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGCz Azm Status Glazing Type Location/Comments 33 Window 6.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 34 Window 20.0 0.390 NFRC 0.37 NFRC 228 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 35 Window 20.0 0.390 NFRC 0.37 NFRC 228 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 36 Window 20.0 0.390 NFRC 0.37 NFRC 228 New Sierra Pacific Windows & Doors Zone 3 MOM 37 Wndow W W ...20.0 0.390 NFRC:..W..:--.W 228 New ... Sierra;Pacific,.Wndows &_Doors Zone 3 KiUDin 38 Window" " 'N-22.0 0.390 `NFRC,.,' � 0.37 :NFRC 'i : '298 New -;,'a Sierra`Pacific Windows'&'Doors Zone 3 Kit/Din 39 Window '"36.0 0;390 NFRC f ' 0.37 "NFRC 298 New ;, Sierra Pacific Windows &Doors Zone 3. MOM 40 Wndow 6.Or. k0.39Q; NFRC 0.37 NFRC ,..4298 New 'r` Sierra Pacific WMndowsl.& Doors Zone,3 KibDin 41 Window 1,&0 11 0.39.0 NFRC 0.37 NFRC 4,318 New ,k , - Sierra Pacific Windows &'Doors Zone; 3 Kit/Din,,,,,, , 42 ,Window 4 ,;)15.0,=. l 0.390, NFRC 0.37 NFRC _ ; 318'Neww-t Sierra Pacific Windows & Doors Zone 3 Kit/Din,' 1' 43 Window s f kjao> „;0.390 NF_RCL. ` ---eci.37 NFRC �318 New Siert; Pacific Windows &:-Doors Zo4',3 Kit/Din. -- 44 Window 10.0 0 390 NFRC 0.37 NFRC 318 New Sierra Pacific Windows & Door`s Zone 3 KibDin 45 Window 10.0 0.390 NFRC 0.37 NFRC 318 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 46 Window 4.9 0.390 NFRC 0.37 NFRC 48 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 47 Window 6.0 0.390 NFRC 0.37 NFRC 78 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 48 Window 6.0 0.390 NFRC 0.37 NFRC 78 New Sierra Pacific Windows & Doors Zone 3 2nd Floor (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 1.16-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t I Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 18ug Screen 0.76 48 JBug Screen 1 0,761 1 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Page 8 of 10 Reg: 212-N0049881B-000000000-0000 Registration Date/Time: 2012/09/10 11:26:33 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2012 Electronically Signed at Ca10ERTS.com by Lance Alacano (Sunrose Corporation) 9/26/2012 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Fishoff Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 912512012 OPAQUE SURFACE DETAILS Surface U- Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments -Type FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 49 Window 6.0 0.390 NFRC 0.37 NFRC 78 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 50 Window 16.8 0.390 NFRC 0.37 NFRC 138 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 51 window 20.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 52 Window 20.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 53 Window„ -,;-_..20.0 0.390 NFRC .. ...0.37, NFRC___ ___..208 New:Sierra,Pacific.Windows &..Doors Zone 3 2nd Floor 54 Window' 120.0 0.390 'NFRC .,o , 0.37 .NFRC . 208 New � Sierra`Pacific Windows"&'Doors Zone 3 2nd Floor 55 Window 8.0 0.390 NFRC J 0.37 NFRC 298 New .F Sierra Pacific Windows &'Doors Zone 3 2nd Floor 56 Window 8.0 ` 0.390 NFRC 0.37 NFRC w4 298 New Sierra Pacific Windows & Doors Zone 3 2nd Floor- -57 57 Window ,8.'0 10.390 NFRC 'r 0.37 NFRC ri 298 New i Sierra Pacific Windows &`Doors Zone 3 2nd Floor,,, �. 58 Window „d J 8:0 � 0.390 NFRC, _ . 0.37 NFRC ;298 New, .1 Sierra Pacific Windows & Doors Zone 3 2nd Floor 59 . WindowA i k"8.0 -0.390 NFRC.?'.- X0.37 NFRC. 11.X298 New Sierra"Pacific Windows & Doors Zorie'3 2nd Floor 0 60 Window 3.0 0.390 NFRC - 0.37 NFRC ' . 298 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 61 Window _ 20.0 0.390 NFRC 0.37 NFRC 318 New Sierra Pacific Windows & Doors Zone 3 2nd Floor (1) Ll -Factor Type: 2 SHGC Type: 1161 = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove hanq Left Fin Ri ht Fin Len H t LExt RExt Dist Len H t Dist Len H t 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 8.0 2.5 10.0 0.1 10.0 10.0 52 Bug Screen 0.76 8.0 2.5 10.0 0.1 10.0 10.0 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 58 Bug Screen 0.76 59 Bug Screen 0.76 60 Bug Screen 0.76 61 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Page 9 of 10 Reg: 212-N0049881B-000000000-0000 Registration Date/Time: 2012/09/10 11:26:33 HERS Provider: CalCERTS, inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2012 Electronically Signed at CalCERTS.com by Lance Alacano (Sunrose Corporation) 9/26/2012 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Fishoff Residence Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1912512012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built HVAC 1 Zone 1 Bedrooms 1,452 15,246 HVAC 2 Master Suite 736 10,672 HVAC 3 Great 1,058 19,044 HVAC 4 Kitchen/Dining 2440 25,620 HVAC 5 2nd Floor 1,294 14,234 Totals 1 6,9801 0 0 01 1 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC 2 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC 3 p '" -;' 1 Central Furnace , 80% AFUE Slit Air Conditioner 14.5 SEER Setback New HVAC 4.(' 2 Central Furnace ; 80% AFUE Split Air Conditioner 15.2 SEER Setback New HVAC 5 1 Central Furnace 80% AF, UE Split Air Conditioner ,1 15.0 SEER ISetback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 IZI New HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 d New HVAC 4 1 Ducted I Ducted JAttic, Ceiling Ins, vented 1 8.01 1 New HVAC 5 1 Ducted I Ducted JAttic, Ceiling Ins, vented 1 8.01 1 New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White 75 Gal 2 Small Gas All Pipes Ins 65,000 75 0.65 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o ro 75 y Q System Name Pipe Len th Pipe Diameter Insul. Thick. aty. HP Plenum Outside Buried 13 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Pae 10 of 10 Reg: 212-N0049881B-000000000-0000 Registration Date/Time: 2012/09/10 11:26:33 HERS Provider: Ca10ERTS, Inc E -d N SINGLE LINE DIAGRAM N 400 AMP MAIN SERVICE 200 AMP SUBPANEL 100 AMP SUBPANEL @ SERVICE @ GARAGE M 200/2 3 3/OCU + 1 #4 GRD 200/2 2" CONDUIT 10012 3 #2 C + 1 #8 GRD 1 1/2" CONDUIT #4 CU TO GAS & WATER 3/0 CU GRND TO UFER HEGGE ELECTRICAL CONTRACTORS INC. 83-852 AVE. 45 INDIO, CA. 92201 LIC# 748171 JIM HEGGE • BUILDING ENERGY ANALYSIS REPORT PROJECT: Fishoff Residence 52-455 Via Savona, The Hideaway La Quinta, CA 92253 Project Designer: Stephen V. Harrel, Architect 141 N. Duesenberg Drive, Suite 14 Westlake Village, CA 91362 (805) 379-1071 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive :I Palm Desert, Ca 92211 C11"Y OF LA QUINT BUILDING & SAFETY DEF APPROVED FOR CONSTRUCTION DATE %0 BY r (76T0) 200-4780 - LZ SEP 26 2012 BY: Job Number: Date: 9/25/2012 I* 0 I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 13 HVAC System Heating and Cooling Loads Summary 16 Room Load Summary 21 Room Heating Peak Loads 26 Room Cooling Peak Loads 31 EnergyPro 5.1 by EnergySoft Job Number ID: User Number: 6712 0 • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Fishoff Residence Building Type o Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/25/2012 Project Address 52-455 Via Savona, The Hideaway La QL California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 6,980 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 5,686 Radiant Barrier New Wall Wood Framed R-21 6,902 New Door Opaque Door None 120 New Slab Unheated Slab -on -Grade None 5,886 Perim = 726' New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Left (SE) 48.0 0.390 0.37 none none Bug Screen New Right (NM 100.0 0.390 0.37 none none Bug Screen New Rear (SM 86.0 0.390 0.37 none none Bug Screen New Rear (SlM 204.0 0.390 0.37 5.0 none Bug Screen New Front (NE) 343.1 0.390 0.37 none none Bug Screen New Front (NE) 1.8 0.390 0.37 none none Bug Screen New Rear (SM 264.0 0.390 0.37 15.0 none Bug Screen New Front (NE) 12.9 0.390 0.37 none none Bug Screen New Left (SE) 88.0 0.390 0.37 4.0 none Bug Screen New Left (SE) 36.0 0.390 0.37 none none Bug Screen New Left (SE) 119.3 0.390 0.37 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 2 Small Gas 75 0.65 All Pipes Ins New Ener Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-25T16:19:52 ID: Page 3 of 39 • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Fishoff Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/25/2012 Project Address 52-455 Via Savona, The Hideaway La Qt, California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,980 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST' ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity ( Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Rear (SW 62.0 0.390 0.37 10.0 none Bug Screen New Rear (Sw) 80.0 0.390 0.37 none none Bug Screen New Right (NK9 107.0 0.390 0.37 none none Bug Screen New Right (Nle 80.0 0.390 0.37 none none Bug Screen New Left (E) 18.0 0.390 0.37 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 15.2 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number., 6712 RunCode: 2012-09-25716:19:52 ID: Page 4 of 39 • C7 • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Fishoff Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/25/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow re uirements and fan watt draw re uirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 1,091.0 ft' Covered Slab loor, 3.500" thick at Zone 1 Bedrooms HIGH MASS Design - Verify Thermal Mass: 361.0 ft2 Exposed Slab Floor, 3.500" thick at Zone 1 Bedrooms The HVAC System HVAC 2 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 497.0 ft2 Covered Slab Floor, 3.500" thick at Master Suite HIGH MASS Design - Verify Thermal Mass: 239.0 ft' Exposed Slab Floor, 3.500" thick at Master Suite The HVAC System HVAC 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 116.0 ft2 Covered Slab Floor, 3.500" thick at Great HIGH MASS Design - Verify Thermal Mass: 942.0 ft2 Exposed Slab Floor, 3.500" thick at Great HIGH MASS Design - Verify Thermal Mass: 1,184.0 ft2 Covered Slab Floor, 3.500" thick at Kitchen/Dining HIGH MASS Design -Verify Thermal Mass: 1,456.0 ft2 Exposed Slab Floor, 3.500" thick at Kitchen/Dining The Roof R-38 Roof(R.38.2x 14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 5 Ton includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 3 Ton includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 incorporates HERS'Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 4 Ton includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 3.5Ton includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. �E_n_ergyPro 5.1 by EnerqySoft User Number.' 6712 RunCode: 2012-09-25716:19:52 ID: Pa e 5 of 39 • • 0 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Fishoff Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/25/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 5 Ton includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. kn-emyPro 5.1 by EnerqySoft User Number: 6712 Run Code: 2012-09-25716:19:52 ID: Page 6 of 39 .7 • • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type io Single Family ❑ Addition Alone Date Fishoff Residence 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 9/25/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/V r Space Heating 5.7i 5.93 -0.22 Space Cooling 55.40 47.28 8.12 Fans 11.10 14.00 -2.90 Domestic Hot Water 4.92 5.33 -0.41 Pumps 0.00 0.00 0.00 Totals 77.13 72.55 4.58 Percent Better Than Standard: 5.9% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NE) 28 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (NE) 2,205 358 Fuel Available at Site: Natural Gas (SE) 2,180 309 Raised Floor Area: 0 (SW) 1,912 696 Slab on Grade Area: 5,886 (NM 2,375 287 Average Ceiling Height: 12.2 Roof 5,686 0 Fenestration Average U -Factor: 0.39 TOTAL: 1,650 Average SHGC: 0.37 Fenestration/CFA Ratio: 23.6% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and compl te. Documentation Author Company Scott Design and Title 24, Inc, 9/25/2012 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Stephen V. Harrel, Architect Address 141 N. Duesenberg Drive, Suite 14 Name Stephen V. Harrell- :�L Signed City/State/Zip Westlake Village, CA 91362 Phone (805) 379-1071 License # Date 3 Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Page 7 of 39 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Fishoff Residence Building Type m Single Family ❑Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1912512012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,452 0.026 R-38 270 0 New 4.2.1-A9 Zone 1 Bedrooms Wall 416 0.069 R-21 58 90 New 4.3.1-A6 Zone 1 Bedrooms Door 24 0.500 None 58 90 New 4.5.1-A4 Zone 1 Bedrooms Wall 440 0.069 R-21 148 90 New 4.3.1-A6 Zone 1 Bedrooms Wall 30 0.069 R-21 238 90 New 4.3.1-A6 Zone 1 Bedrooms Wall 260 0.069 R-21 328 90 New 4.3.1-A6 Zone 1 Bedrooms Slab 1,091 0.730 None 0 180 New 4.4.7-A1 Zone 1 Bedrooms Slab 361 0.730 None 0 180 New 4.4.7-A1 Zone 1 Bedrooms Roof 736 0.026 R-38 270 0 New 4.2.1-A9 Zone 2 Master Suite Wall 73 0.069 R-21 118 90 New 4.3.1-A6 Zone 2 Master Suite Wall 244 0.069 R-21 148 90 New 4.3.1-A6 Zone 2 Master Suite Wall 292 0.069 R-21 208 90 New 4.3.1-A6 Zone 2 Master Suite Wall 319 0.069 R-21 298 90 New 4.3.1-A6 Zone 2 Master Suite Slab 497 0.730 None 0 180 New 4.4.7-A 1 Zone 2 Master Suite Slab 239 0.730 None 0 180 New 4.4.7-A1 Zone 2 Master Suite Roof 1,058 0.026 R-38 270 0 New 14.2.1-A9 17nne 3 Great FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 8.0 0.390 NFRC 0.37 NFRC 148 New Sierra Pacific Windows & Doors Zone 1 Bedrooms 2 Window 4.0 0.390 NFRC 0.37 NFRC 148 New Sierra Pacific Windows & Doors Zone 1 Bedrooms 3 Window 4.0 0.390 NFRC 0.37 NFRC 148 New Sierra Pacific Windows & Doors Zone 1 Bedrooms 4 Window 4.0 0.390 NFRC 0.37 NFRC 148 New Sierra Pacific Windows & Doors Zone 1 Bedrooms 5 Window 8.0 0.390 NFRC 0.37 NFRC 148 New Sierra Pacific Windows & Doors Zone 1 Bedrooms 6 Window 8.0 0.390 NFRC 0.37 NFRC 148 New Sierra Pacific Windows & Doors Zone 1 Bedrooms 7 Window 4.0 0.390 NFRC 0.37 NFRC 148 New Sierra Pacific Windows & Doors Zone 1 Bedrooms 8 Window 30.0 0.390 NFRC 0.37 NFRC 328 New Sierra Pacific Windows & Doors Zone 1 Bedrooms 9 Window 20.0 0.390 NFRC 0.37 NFRC 328 New Sierra Pacific Windows & Doors Zone 1 Bedrooms 10 Window 20.0 0.390 NFRC 0.37 NFRC 328 New Sierra Pacific Windows & Doors Zone 1 Bedrooms 11 Window 30.0 0.390 NFRC 0.37 NFRC 328 New Sierra Pacific Windows & Doors Zone 1 Bedrooms 12 Window 8.0 0.390 NFRC 0.37 NFRC 148 New Sierra Pacific Windows & Doors Zone 2 Master Suite 13 Window 8.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 2 Master Suite 14 Window 32.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 2 Master Suite 15 Window 120.0 0.390 NFRC 0.37 NFRC 208 New I Sierra Pacific Windows & Doors Zone 2 Master Suite 16 Window 96.0 0.390 NFRC 0.37 NFRC 28 New I Sierra Pacific Windows & Doors Zone 3 Great (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-8 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hot Wd Ove hanq Left Fin Ri ht Fin Len Hot LExt RExt Dist Len Hot Dist I Len Hot 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bua Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 JBug Screen 1 0.761 10.01 12.0 5.0 0.1 5.0 5.0 16 IBug Screen 1 0.761 1 Ener Pro 5.1 by Ener Soft User Number., 6712 Run Code: 2012-09-25716:19:52 ID: Page 8 of 39 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Fishoff Residence Building Type 5 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/25/2012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Wall 448 0.069 R-21 28 90 New 4.3.1-A6 Zone 3 Great Wall 92 0.069 R-21 58 90 New 4.3.1-A6 Zone 3 Great Wall 140 0.069 R-21 78 90 New 4.3.1-A6 Zone 3 Great Wall 254 0.069 R-21 208 90 New 4.3.1-A6 Zone 3 Great Wall 120 0.069 R-21 328 90 New 4.3.1-A6 Zone 3 Great Slab 116 0.730 None 0 180 New 4.4.7-A1 Zone 3 Great Slab 942 0.730 None 0 180 New 4.4.7-A1 Zone 3 Great Roof 1,146 0.026 R-38 270 0 New 4.2.1-A9 Zone 3 MOO Wall 110 0.069 R-21 28 90 New 4.3.1-A6 Zone 3 Kit/Din Wall 448 0.069 R-21 48 90 New 4.3.1-A6 Zone 3 Kit/Din Door 24 0.500 None 48 90 New 4.5.1-A4 Zone 3 MOM Wall 118 0.069 R-21 118 90 New 4.3.1-A6 Zone 3 Kit/Din Wall 268 0.069 R-21 138 90 New 4.3.1-A6 Zone 3 Kit/Din Wall 315 0.069 R-21 208 90 New 4.3.1-A6 Zone 3 Kit/Din Wall 130 0.069 R-21 228 90 New 14.3.1-A6 Zone 3 Kit/Din Wall 4161 0.069 R-21 298 90 New 14.3.1-A6 JZone 3 Kit/Din FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 17 Window 7.1 0.390 NFRC 0.37 NFRC 28 New Sierra Pacific Windows & Doors Zone 3 Great 18 Window 240.0 0.390 1 NFRC 0.37 NFRC 28 New Sierra Pacific Windows & Doors Zone 3 Great 19 Window 1.8 0.390 NFRC 0.37 NFRC 58 New Sierra Pacific Windows & Doors Zone 3 Great 20 Window 240.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 Great 21 Window 8.0 0.390 NFRC 0.37 NFRC 48 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 22 Window 88.0 0.390 NFRC 0.37 NFRC 118 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 23 Window 36.0 0.390 NFRC 0.37 NFRC 118 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 24 Window 30.0 0.390 NFRC 0.37 NFRC 138 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 25 Window 12.5 0.390 NFRC 0.37 NFRC 138 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 26 Window 20.0 0.390 NFRC 0.37 NFRC 138 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 27 Window 20.0 0.390 NFRC 0.37 NFRC 138 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 28 Window 20.0 0.390 NFRC 0.37 NFRC 138 New Sierra Pacific Windows & Doors Zone 3 MOM 29 Window 22.01 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 30 Window 24.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 31 Window 60.01 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 32 Window 24.01 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 Kit/Din (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t FWd Ove hanq Left Fin Ri ht Fin Len H t LExt RExt Dist Len I H t Dist I Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 10.0 24.0 15.0 0.1 15.0 15.0 21 Bug Screen 0.76 22 Bug Screen 0.76 8.0 11.0 4.0 0.1 4.0 4.0 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 5.5 4.0 10.0 0.1 10.0 10.0 30 Bug Screen 0.76 8.0 3.0 15.0 0.1 15.0 15.0 31 IBug Screen 0.76 6.0 10.0 5.0 0.1 5.0 5.0 32 JBug Screen 0.76 8.0 3.0 5.0 0.1 5.0 5.0 -En-ergyPro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Pa e 9 of 39 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Fishoff Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/25/2012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm I Tilt Status 4 Location/Comments Door 24 0.500 None 298 90 New 4.5.1-A4 Zone 3 Kit/Din Wall 332 0.069 R-21 318 90 New 4.3.1-A6 Zone 3 MOO Door 24 0.500 None 318 90 New 4.5.1-A4 Zone 3 Kit/Din Door 24 0.500 None 318 90 New 4.5.1-A4 Zone 3 Kit/Din Slab 1,184 0.730 None 0 180 New 4.4.7-A 1 Zone 3 Kit/Din Slab 1,456 0.730 None 0 180 New 4.4.7-A1 Zone 3 Kit/Din Roof 1,294 0.026 R-38 270 0 New 4.2.1-A9 Zone 3 2nd Floor Wall 50 0.069 R-21 28 90 New 4.3.1-A6 Zone 3 2nd Floor Wall 235 0.069 R-21 48 90 New 4.3.1-A6 Zone 3 2nd Floor Wall 325 0.069 R-21 78 90 New 4.3.1-A6 Zone 3 2nd Floor Wall 263 0.069 R-21 138 90 New 4.3.1-A6 Zone 3 2nd Floor Wall 195 0.069 R-21 208 90 New 4.3.1-A6 Zone 3 2nd Floor Wall 409 0.069 R-21 298 90 New 4.3.1-A6 Zone 3 2nd Floor Wall 160 0.069 R-21 318 90 New 4.3.1-A6 Zone 3 2nd Floor FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 6.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 34 Window 20.0 0.390 NFRC 0.37 NFRC 228 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 35 Window 20.0 0.390 NFRC 0.37 NFRC 228 New Sierra Pacific Windows & Doors Zone 3 KitlDin 36 Window 20.0 0.390 NFRC 0.37 NFRC 228 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 37 Window 20.0 0.390 NFRC 0.37 NFRC 228 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 38 Window 22.0 0.390 NFRC 0.37 NFRC 298 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 39 Window 36.0 0.390 1 NFRC 0.37 NFRC 298 New Sierra Pacific Windows & Doors Zone 3 KittDin 40 Window 6.0 0.390 NFRC 0.37 NFRC 298 New Sierra Pacific Windows & Doors Zone 3 KitYDin 41 Window 15.0 0.390 NFRC 0.37 NFRC 318 New Sierra Pacific Windows & Doors Zone 3 KibDin 42 Window 15.0 0.390 NFRC 0.37 NFRC 318 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 43 Window 10.0 0.390 NFRC 0.37 NFRC 318 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 44 Window 10.0 0.390 NFRC 0.37 NFRC 318 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 45 Window 10.0 0.390 NFRC 0.37 NFRC 318 New Sierra Pacific Windows & Doors Zone 3 Kit/Din 46 Window 4.9 0.390 NFRC 0.37 NFRC 48 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 47 Window 6.0 0.390 NFRC 0.37 NFRC 78 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 48 Window 6.0 0.390 NFRC 1 0.37 NFRC 78 New Sierra Pacific Windows & Doors Zone 3 2nd Floor (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Ri ht Fin Len H t LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bu Screen 0.76 43 Bu Screen 0.76 44 Bug Screen 0.76 45 Bu Screen 0.76 46 Bu Screen 0.76 47 Bug Screen 0.76 48 JBug Screen 0.76 EnerqyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Pae 10 of 39 • 0 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Fishoff Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1912512012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 49 Window 6.0 0.390 NFRC 0.37 NFRC 78 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 50 Window 16.8 0.390 NFRC 0.37 NFRC 138 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 51 Window 20.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 52 Window 20.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 53 Window 20.0 0.390 NFRC 0.37 NFRC 208 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 54 Window 20.0 0.390 NFRC 0.37 NFRC 2081 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 55 Window 8.0 0.390 NFRC 0.37 NFRC 298 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 56 Window 8.0 0.390 NFRC 0.37 NFRC 298 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 57 Window 8.0 0.390 NFRC 0.37 NFRC 298 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 58 Window 8.0 0.390 NFRC 0.37 NFRC 298 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 59 Window 8.0 0.390 NFRC 0.37 NFRC 298 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 60 Window 3.0 0.390 NFRC 0.37 NFRC 298 New Sierra Pacific Windows & Doors Zone 3 2nd Floor 61 Window 20.0 0.390 NFRC 0.37 NFRC 318 New Sierra Pacific Windows & Doors Zone 3 2nd Floor (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hat I Wd Ove hanq Left Fin Ri ht Fin Len Hot LExt REA Dist Len Hat Dist Len Hat 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 8.0 2.5 10.0 0.1 10.0 10.0 52 Bug Screen 0.76 8.0 2.5 10.0 0.1 10.0 10.0 53 Bug Screen 0.76 54 Buq Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 58 Bug Screen 0.76 59 Buq Screen 0.76 60 Bug Screen 0.76 61 Bug Screen 0.76 Ene Pro 5.1 b Ene Soft User Number: 6712 Run Code: 2012-09-25716:19:52 ID: Pae 11 of 39 • • • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Fishoff Residence Building Type D Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1912512012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built HVAC 1 Zone 1 Bedrooms 1,452 15,246 HVAC 2 Master Suite 736 10,672 HVAC 3 Great 1,058 19,044 HVAC 4 Kitchen/Dining 2,440 25,620 HVAC 5 2nd Floor 1,294 14,234 Totals 6,980 01 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC 2 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC 3 1 Central Furnace 80% AFUE Split Air Conditioner 14.5 SEER Setback New HVAC 4 2 Central Fumace 80% AFUE Split Air Conditioner 15.2 SEER Setback New HVAC 5 1 Central Furnace 80% AFUE Split Air Conditioner 15.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Coolinq Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 3 Ducted Ducted Attic, Ceiling Ins, vented 8.0 El New HVAC 4 Ducted Ducted Attic, CeilingIns, vented 8.01 El INew HVAC 5 1 Ducted Ducted Attic, Ceiling Ins, vented 8.01 m INew WATER HEATING SYSTEMS S stem Name aty. Type Distribution Rated Input (Btu h) Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White 75 Gal 2 Small Gas All Pipes Ins 65,000 75 0.65 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o 5 Q System Name Pipe Lencith Pipe Diameter Insul. Thick. Ot . HP Plenum Outside Buried EnergyPro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Pae 12 of 39 C MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Fishoff Residence Date 1 9/25/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150 f : Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the CF -113 Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.36%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical dama a and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight-fittinn damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. 'Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of 1 1 13 c 5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACOA. §150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. '§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §150(1)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. I . EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2012-09-25716:19:52 ID: Page 13 of 39 0 C • MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Fishoff Residence 9/25/2012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction _§114(b)1: and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150(p). Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. §150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 4150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoR User Number: 6712 Run Code: 2012-09-25T16:19:52 ID: Page 14 of 39 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Fishoff Residence 9/25/2012 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters • Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not -be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-25T16:19:52 ID: Page 15 of 39 C HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Fishoff Residence Date 9/25/2012 System Name HVAC 1 Floor Area 1,452 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 1,059 14,004 Return Vented Lighting 0 Return Air Ducts 660 Return Fan 0 Ventilation 0 0 Supply Fan 2,811 Supply Air Ducts 660 TOTAL SYSTEM LOAD 1 18,134 COIL HTG. Latent CFM 2.7111 436 0 0 2,711 PEAK Heating System Sensible Output per System 89,000 19,694 Total Output Btuh 89,000 Output Btuh/s ft 61.3 752 Cooling System 0 Output per System 54,000 0 Total Output Btuh 54,000 -2,811 Total Output Tons 4.5 752 Total Output Btuh/s ft 37.2 Total Output (sqft/Ton 322.7 1 18,387 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 5 Ton 30,588 Total Adjusted System Output 30,588 (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 14,511 89,000 14,511 89,000 Aug 3 PM Jan 1 AM Airflow cfm/s ft 1.38 Airflow cfm/Ton 444.4 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 113 OF 115 OF Heating Coil Supply Fan 114 OF 2,000 cfm ROOM r' 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 70 / 61 OF 70/61°F 56/55°F 57/56°F � Cooling Coil Supply Fan 58 / 56 OF 2,000 cfm 59.9% ROOM in 70/ 61 OF EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2012-09-25716:19:52 ID: Page 16 of 39 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Fishoff Residence Date 9/25/2012 System Name HVAC 2 Floor Area 736 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 525 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 51,000 9,391 1,4731 318 13,258 Total Output Btuh 51,000 0 Output Btuh/s ft 69.3 442 506 Cooling System 0 0 Output perSystem 34,000 0 0 0 0 Total Output Btuh 34,000 0 1,473 0 Total Output ons 2.8 442 506 Total Output Btuh/s ft 46.2 Total Output s ft/Ton 259.8 10,276 1 14,271 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 3Ton 22,348 5,268 51,000 Airflow cfm/s ft 1.63 51,000 I Jan 1 AM Airflow cfm/Ton 423.5 Outside Air % 0.0% Total Adjusted System Output 22,3481 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 5,268 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfM 72 OF 72 OF 112 OF 112 °F D Heating Coil Supply Fan 111 OF 1,200 cfm ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside AirAr 0 cfm 70 / 59 OF 70/59°F 53/52°F 53!52°F s Cooling Coil Supply Fan 53 ! 52 OF 1,200 cfm _...... .... 52.9% ROOM 70/ 59 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012.09-25T16:19:52 ID: Page 17 of 39 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Fishoff Residence Date 9/25/2012 System Name HVAC 3 Floor Area 1,058 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 1,655 26,478 Return Vented Lighting 0 Return Air Ducts 1,248 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 1 1,248 TOTAL SYSTEM LOAD 28,973 COIL HTG. Latent CFM 1,830 547 0 0 1,830 PEAK Heating System Sensible Output per Sys 71,000 23,664 Total Output Btuh 71,000 Output Btuh/s ft 67.1 903 Cooling System 0 Output per System 47,500 0 Total Output Btuh 47,500 0 Total Output ons 4.0 903 Total Output Btuh/s ft 44.9 Total Output s ft/Ton 267.3 25,471 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Carrier 4Ton 28,098 10,994 71,000 Airflow cfm/s ft 1.51 Total Adjusted System Output 1 28,098 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 10,994 71,000 Aug 3P ml F Jan 1 AM Airflow cfm/Ton 404.2 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 71 ,F 71 OF 113 OF 113 °F i Heating Coil Supply Fan 113OF 1,600 cfm _ ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112178 OF Outside Air 0 cfm 71 160 OF 4 :0, 71 / 60 OF 54 / 53 OF 54 / 53 OF Cooling Coil Supply Fan 55 / 54 OF 1,600 cfm 55.7% ROOM K 70/ 60 OF J 4 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2012-09-25T16:19:52 /D: Page 18 of 39 C. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Fishoff Residence Date 9/25/2012 System Name HVAC 4 Floor Area 2,440 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL COOLING CFM Sensible Total Room Loads 1,697 33,566 Return Vented Lighting 0 Return Air Ducts 1,582 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 1,582 TOTAL SYSTEM LOAD 1 36,729 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output erS stem 71,000 4,620 782 38,826 Total Output Btuh 142,000 Output Btuh/s ft 58.2 1,482 Cooling System 0 Output perSystem 41,500 0 0 0 Total Output Btuh 83,000 4,620 0 Total Output ons 6.9 1,482 Total Output Btuh/s ft 34.0 Total Output s ft/Ton 352.8 1 41,790 Air System CFM perSystem 1,400 HVAC EQUIPMENT SELECTION Airflow cfm 2,800 Carrier 3.5Ton 58,561 Total Adjusted System Output 1 58,561 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 8,005 142,000 8,005 1 142,000 Aug 3 PM I Jan 1 AM Airflow cfm/s ft 1.15 Airflow cfm/Ton 404.8 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF = Outside Air 0 cfm 72 OF 72 OF 119 °F 119 °F Heating Coil Supply Fan 119OF 2,800 cfm ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 0 cfm 71 / 58 OF 71 /59°F 51 /50°F 51 /50°F Cooling Coil Supply Fan 51 / 50 OF 2,800 cfm _............. ........ 49.5% ROOM 70/ 58 OF EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2012-09-25716:19:52 ID: Page 19 of 39 C. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Fishoff Residence Date 9/25/2012 System Name HVAC 5 Floor Area 1,294 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,142 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 15,168 2,438 321 14,577 Total Output Btuh 89,000 0 Output Btuh/s ft 68.8 715 556 Cooling System 0 0 Output perSystem 54,0001 0 0 0 0 Total Output Btuh 54,000 2,811 2,438 -2,811 Total Output ons 4.5 715 556 Total Output Btuh/s ft 41.7 Total Output s ft/Ton 287.6 1 19,408 1 12,880 'Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 5 Ton 30,792 14,247 89,000 Airflow cfm/s ft 1.55 89,000 F Jan 1 AM Airflow cfm/Ton 444.4 Outside Air % 0.0% Total Adjusted System Output 30,792 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 14,247 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air Ar 0 cfm 72 OF 72 OF 114 OF 115 OF Heating Coil Supply Fan o 115 F 2,000 cfm ROOM IL 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 0 cfm 70 / 61 OF 70/61°F 56/55°F 57/56°F Cooling Coil Supply Fan 58 / 56 OF 2,000 cfm ,.... 59.6% � ROOM In 70/ 61 OF EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2012-09-25716:19:52 ID: Page 20 of 39 0 C] ROOM LOAD SUMMARY Project Name Date Fishoff Residence 9/25/2012 System Name Floor Area HVAC 1 1,452 ROOM LOAD SUMMARY 71 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name I Room Name Mult. I CFM I Sensible I Latent CFM Sensible I Latent CFM I Sensible Zone 1 Bedrooms Izone 1 Bedrooms 1 1 1,0591 14,0041 2,711 1,059 14,0041 2,711 4361 19,694 PAGE TOTAL TOTAL' 1,059 14,004 2,711 436 19,694 1,0591 14,004 2,711 436 19,694 Total includes ventilation load for zonal systems. Ener Pro 5.1 by EnergySoft User Number. 6712 RunCode: 2012-09-25716:19:52 ID: Pa a 21 of 39 0 • • ROOM LOAD SUMMARY Project Name Date Fishoff Residence 9/25/2012 System Name Floor Area HVAC 2 736 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM I Sensible I Latent CFM I Sensible Zone 2 Master Suite Master Suite I 1 1 5251 9,3911 1,473 5251 9,3911 1,473 318 13,258 PAGE TOTAL TOTAL* 525 9,391 1,473 318 13,258 525 9,391 1,473 318 13,258 * Total includes ventilation load for zonal systems. EnerqyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2012-09-25T16:19:52 ID: Pa a 22 of 39 • :7 ROOM LOAD SUMMARY Project Name Date Fishoff Residence 9/25/2012 System Name Floor Area HVAC 3 1,058 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible' I Latent CFM Sensible I Latent CFM I Sensible Zone 3 Great I Great I 1 1 1,6551 26,4781 1,830 1,6551 26,4781 1,830 5471 23,664 PAGE TOTAL TOTAL' 1,6551 26,4781 1,8301 547 23,664 1,655 26,478 1,830 547 23,664 Total includes ventilation load for zonal systems. EnercvPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Pa a 23 of 39 C • • • • • ROOM HEATING PEAK LOADS Project Name7912512012 Fishoff Residence te ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 1 Bedrooms Floor Area 1,452.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area R-38 Roof(R. 38.2x 14.16) 1,452.0 R-21 Wall (W.19.2x6.16) 1,146.0 Wood Door 24.0 Sierra Pacific Windows & Doors 140.0 Slab -On -Grade perim = 183.0 Items shown with an asterisk (') denote conduction through an interior surface Infiltration:[ 1.00 X 1.064 X 1,452 X Schedule Air Sensible Area Fraction U -Value X 0.0260 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr 46 1,737 X 0.0690 46 3,637 X X 0.5000 46 552 0.3900 46 2,512 X X X X X X 0.7300 46 6,145 X X X X X X X X X X X X X X X X X X X X X to another room 10.50 X 0.411 Ceiling Height ACH Page Total /60] X AT 14,583 = 5,111 TOTAL HOURLY HEAT LOSS FOR ROOM 19,694 EnergyPro 5.1 by EnergySoR User Number: 6712 Run Code: 2012-09-25716:19:52 ID: Page 26 of 39 • • ROOM HEATING PEAK LOADS Project Name Fishoff Residence Date 1 9/25/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Floor Area 736.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction 1.064 Area 736.0 X U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x 14.16) 0.0260 46 880 R-21 Wall (W.19.2x6.16) 928.0 X 0.0690 46 2,945 Sierra Pacific Windows & Doors 168.0 X X 0.3900 46 3,014 Slab -On -Grade perim = 114.0 0.7300 46 3,828 X X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to X 736 X Area Ceiling F-10,668 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction another room 14.50 X 0.298 Height ACH Page Total /60] X AT = 2,591 TOTAL HOURLY HEAT LOSS FOR ROOM 13,258 EnergyPro 5 1 by EnergySoR User Number: 6712 Run Code: 2012-09-25716:19:52 ID: Page 27 of 39 • 0 • ROOM HEATING PEAK LOADS Project Name7912512012 Fishoff Residence te ROOM INFORMATION DESIGN CONDITIONS Room Name Great Floor Area 1,058.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 1,058.0 X 1,054.1 X 584.9 X U -Value 0.0260 X 0.0690 X 0.3900 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X X X another room 18.00 X 0.240 Height ACH AT OF = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x 14.16) 46 1,265 R-21 Wall (W.19.2x6.16) 46 3,346 Sierra Pacific Windows & Doors 46 10,493 Slab -On -Grade perim = 144.0 X X X X 46 4,836 X X X X X X X X X X X X X X X X X X X X X X X XI through an interior surface to X 1,058 X Area Ceiling Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction Page Total /60] X AT 19,940 = 3,724 TOTAL HOURLY HEAT LOSS FOR ROOM 23,664 rE,;eyP�,o5�1 by EnergySoft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Page 28 of 39 s • • ROOM HEATING PEAK LOADS Project NameDate Fishoff Residence 9/25/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen/Dining Floor Area 2,440.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 1,146.0 X 2,136.5 X U -Value AT °F X 46 . = X 46 = Btu/hr R-38 Roof(R.38.2x14.16) 0.0260 1,371 R-21 Wall (W.19.2x6.16) 0.0690 6,781 Sierra Pacific Windows & Doors 574.5 X X 0.3900 X X 46 = = 10,307 Wood Door 96.0 0.5000 46 2,208 Slab -On -Grade perim = 285.0 X X X X X X 0.7300 X X 46 = = 9,570 X = X X X X X = = = = = X X X X X X = = X X X X = X X = = X X X X = = = X X X X = X X X X X X = = = X X = X X = X X X = X = X X X through an interior surface to 1.064 X 2,440 X Area Ceiling X X = = X = Page Total /60] X 46 AT Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction another room 10.50 X 0.411 Height ACH 1 30,237 = 8,589 TOTAL HOURLY HEAT LOSS FOR ROOM 38,826 EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Page 29 of 39 i �J ROOM HEATING PEAK LOADS Project Name Fishoff Residence Date 9/25/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Floor Area 1,294.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value AT OF = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Roof(R.38.2x 14.16) 1,294.0 0.0260 X X X X X X X 46 1,548 R-21 Wall (W.19.2x6.16) 1,637.4 0.0690 46 5,197 Sierra Pacific Windows & Doors 182.7 0.3900 46 3,278 X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,294 X Area another room 11.00 X 0.392 Height ACH Page Total /60] X AT 10,022 = 4,555 TOTAL HOURLY HEAT LOSS FOR ROOM 14,577 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Page 30 of 39 0 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Fishoff Residence 1 9/25/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 1 Bedrooms Outdoor Dry Bulb Temperature 112 OF Floor Area 1,452.0ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF ODaaue Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W. 19.2x6.16) Wood Door R-21 Wall (W.19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) Orientation (SE) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,452.0 0.0260 56.0 416.0 0.0690 30.2 24.0 0.5000 30.2 440.0 0.0690 29.6 30.01 0.0690 31.6 260.0 0.0690 29.4 8.0 27.6 = 27.6 = 27.6 = 0.0 21.5 8.0 0.0 21.5 4.0 0.0 21.5 30.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fpnpstratinn 7 8 8 8 7 7 8 4 d10 Orientation (SE) (SE) I (NIM Btu/hr 2,114 866 362 897 1 651 528 1 4,8321 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF 27.6 = 0.0 21.5 8.0 0.0 21.5 4.0 27.6 = 0.0 21.5 4.0 27.6 = 0.0 21.5 4.0 27.6 = 0.0 21.5 8.0 27.6 = 27.6 = 27.6 = 0.0 21.5 8.0 0.0 21.5 4.0 0.0 21.5 30.0 33.4 = 33.4 = 0.0 21.5 20.0 Page Total Btu/hr 221 110 110 110 221 221 110 1,003 669 Internal Gain Btu/hr 230 1.0 Occupants X 230 Btuh/occ. Occupants = Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Ilnfiltration: 1.064 X 1.27 X 79.45 X 42 = 4,494 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,0041 Latent Gain Btu/hr 200 Btuh/occ. 200 Occupants 1.0 Occupants X = Infiltration: 4,771 X 1.27 X 79.45 X 0.00523 = 2,511 Air Sensible CFM ELA AW • rTOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,711 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name7912512012 te Fishoff Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Zone 1 Bedrooms Outdoor Dry Bulb Temperature 112 OF Floor Area 1,452.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X X X X X = X X X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr d10 (NIM 0.0 X 21.5 + 20.0 X 33.4 = 669 4 (NIA9 0.0 X 21.5 + 30.0 X 33.4 = 1,003 X + X = X + X = X + X X + X = X + X X + X = X +1 X = Page Total 1,671 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 —d Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.27 X 79.45 X 42 = 4,494 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,004 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 1.27 X 79.45 X 0.00523 = 2.511 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,711 EnergyPro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Pacre 32 of 39 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Fishoff Residence 9/25/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 736.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16) (W) 736.0 X 0.0260 X 56.0 = 1,072 R-21 Wall (W.19.2x6.16) (SE) 73.0 X 0.0690 X 31.8 = 160 R-21 Wall (W.19.2x6.16) (SE) 244.0 X 0.0690 X 29.6 = 498 R-21 Wall (W.19.2x6.16) (SW) 292.0 X 0.0690 X 29.1 = 587 R-21 Wall (W. 19.2x6.16) (NIA 319.0 X 0.0690 X 31.3 = 688 X X = X X = X X = X J X = Page Total 3,004 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 7 (SE) 0.0 X 21.5 + 8.0 X 27.6 = 221 1 (SW 0.0 X 21.5 + 8.0 X 26.9 = 215 d7 (SW) 0.0 X 21.5 + 32.0 X 26.9 = 860 d5 (SW) 120.0 X 21.5 + 0.0 X 26.9 = 2,584 X + X - X + X - X + X - X + X - X +1 XI - Page Total 3,87s Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.27 X 40.27 X 42 = 2,278 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,391 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 1.27 X 40.27 X 0.00523 = 1,273 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,473 Ener Pro 5.1 by EnemySoft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Page 33 of 39 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Fishoff Residence 9/25/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Outdoor Dry Bulb Temperature 112 OF Floor Area 1,058.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x 14.16) (IM 1,058.0 X 0.0260 X 77.0 = 2,118 R-21 Wall (W. 19.2x6.16) (NE) 447.9 X 0.0690 X 32.9 = 1,016 R-21 Wall (W. 19.2x6.16) (NE) 92.2 X 0.0690 X 36.9 = 235 R-21 Wall (W. 19.2x6.16) (E) 140.0 X 0.0690 X 41.3 = 399 R-21 Wall (W. 19.2x6.16) (SIM 254.0 X 0.0690 X 46.7 = 819 R-21 Wall (W. 19.2x6.16) (NIM 120.0 X 0.0690 X 46.1 = 382 X X = X X = X J X = Page Total 4,ss8 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr d1 (NE) 0.0 X 26.1 + 96.0 X 34.6 = 3,326 20 (NE) 0.0 X 26.1 + 7.1 X 34.6 = 246 d4 (NE) 0.0 X 26.1 + 240.0 X 34.6 = 8,316 19 (NE) 0.0 X 26.1 + 1.8 X 45.4 = 82 d4 (SIM 240.0 X 26.1 + 0.0 X 63.0 = 6,266 X + X = X + X = X + X = X 1 +1 X = Page Total 18,235 Internal Gain Btu/hr Occupants 0.0 Occupants X 230 Btuh/occ. = 0 Equipment 0.0 Dwelling Unit X 1,200 Btu = 0 Infiltration: 1.064 X 1.27 X 57.89 X 42 = 3,275 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 26,478 Latent Gain Btu/hr Occupants Occupants X 200 Btuh/occ. = o Infiltration: 4,771 X 1.27 X 57.89 X 0.00523 = 1,830 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 830 EnergyPro 5.1 by Ener Soft User Number: 6712 Run Code: 2012-09-25T16:19:52 ID: Page 34 of 39 • • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Fishoff Residence 1 9/25/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen/Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 2,440.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Range: 34 OF I Onanue Surfaces R-38 Roof(R.38.2x14.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W.19.2x6.16) Wood Door R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W.19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) Orientation (tM (NE) (NE) (NE) (SE) (SE) (SW) (Sim Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,146.0 0.0260 56.0 110.0 0.0690 26.7 448.0 0.0690 29.3 24.0 0.5000 29.3 118.0 0.0690 31.8 267.5 0.0690 30.7 315.0 0.0690 29.1 130.0 0.0690 31.1 416.0 0.0690 31.3 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fenestration 7 d6 13 4 2 d9 d9 d9 15 Orientation (SE) I (SIM � Page Total Shaded Area Unshaded GLF Area X 21.5 + 8.0 X 21.5 + 34.5 X 21.5 + 36.0 X 21.5 + 30.0 X 21.5 + 12.5 X 21.5 + 20.0 X 21.5 + 20.0 X 21.5 + 20.0 X 21.5 + 0.0 X X X X X X X X X GLF = = = = = = = = = 0.0 34.1 53.5 31.1 0.0 31.1 0.0 29.5 0.0 29.5 0.0 29.5 0.0 29.5 0.0 29.5 22.0 26.9 Page Total Btu/hr 1, 669 351 259 566 633 279 898 5, 762 Btu/hr 273 2,225 1,120 885 369 590 590 590 474 7.113 Internal Gain X 1.27 CFM X 133.52 ELA Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 Air Sensible X 1.27 CFM X 133.52 ELA X 42 = 7,552 AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 33,566 Latent Gain Btu/hr Occupants 2.0 Occupants X 200 Btuh/occ. = 400 Infiltration: 4.771 X 1.27 X 133.52 X 0.00523 = 4,220 Air Sensible CFM ELA AW 1 4 • • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Fishoff Residence 9/25/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen/Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 2,440.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranqe: 34 OF Opaque Surfaces Wood Door R-21 Wall (W.19.2x6.16) Wood Door Orientation I (NK91 Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 24.0 0.5000 31.3 332.0 0.0690 30.0 48.0 0.5000 30.0 26.9 24.0 21.5 0.0 26.9 0.0 21.5 6.0 26.9 0.0 21.5 20.0 30.2 0.0 21.5 20.0 30.2 0.0 21.5 20.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded I Fanoctratinn d8 14 d8 16 d9 d9 d10 d10 15 Orientation I (S►M I (SIM (StM Btu/hr 1 7211 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = -- 24.0 21.5 0.0 26.9 60.0 21.5 0.0 26.9 24.0 21.5 0.0 26.9 0.0 21.5 6.0 26.9 0.0 21.5 20.0 30.2 0.0 21.5 20.0 30.2 0.0 21.5 20.0 30.2 0.0 21.5 20.0 30.2 0.0 21.5 22.0 37.2 Page Page Total 1, Btu/hr 517 1,292 517 161 605 605 605 605 819 5, 724 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 1.27 X 133.52 X 42 = C Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 33,5661 Latent Gain Btu/hr Occupants 2.0 Occupants X 200 Btuh/occ. = 400 Infiltration: 4.771 X 1.27 X 133.52 X 0.00523 = 4,220 Air Sensible CFM ELA AW n� 0 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name7912512012 te Fishoff Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen/Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 2,440.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total o Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 13 (NIM 0.0 X 21.5 + 36.0 X 37.2 = 1,340 17 (NM 0.0 X 21.5 + 6.0 X 37.2 = 223 9 (NIM 0.0 X 21.5 + 15.0 X 33.4 = 501 9 (NIM 0.0 X 21.5 + 15.0 X 33.4 = 501 6 (NIM 0.0 X 21.5 + 10.0 X 33.4 = 334 6 (NIM 0.0 X 21.5 + 10.0 X 33.4 = 334 6 (NIM 0.0 X 21.5 + 10.0 X 33.4 = 334 X + X = X +1 X = Page Total 3,569 Internal Gain Btu/hr Occupants 2.0 Occupants X 230 Btuh/occ. _ 460 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.27 X 133.52 X 42 = 7,552 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 33,566 Latent Gain Btu/hr Occupants 2.0 Occupants X 200 Btuh/occ. = 400 Infiltration: 4,771 X 1.27 X 133.52 X 0.00523 = 4,220 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,620 Ener Pro 5.1 by Ener Soft User Number: 6712 Run Code: 2012-09-25716:19:52 ID: Page 37 of 39 • • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Fishoff Residence 9/25/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 1,294.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temaerature 70 OF Outdoor Daily Range: 34 OF Onaaue Surfaces R-38 Roof(R.38.2x 14.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) R-21 Wall (W. 19.2x6.16) Orientation (N►M I Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = I = 1,294.0 0.0260 56.0 50.0 0.0690 26.7 235.1 0.0690 29.3 325.1 0.0690 31.9 263.2 0.0690 30.7 195.0 0.0690 29.1 409.0 0.0690 31.3 160.0 0.0690 30.0 20.0 21.5 + 0.0 431 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fana¢tratinn 18 10 10 10 d11 d10 d10 d10 d10 (E) (SW) (SW) Btu/hr 1,884 92 475 716 1 3921 1 5,3301 Shaded Area X X X X X X X X X GLF Unshaded Area GLF X 34.1 X 40.8 X 40.8 X 40.8 X 29.5 X 26.9 X 26.9 X 26.9 X 26.9 Page Total = = = = = = = = = Btu/hr 0.0 21.5 + + + 4.9 167 0.0 21.5 6.0 245 0.0 21.5 6.0 245 0.0 21.5 + 6.0 245 0.0 21.5 + 16.8 495 20.0 21.5 + 0.0 431 20.0 21.5 + 0.0 431 0.0 21.5 + 20.0 537 0.0 21.5 + 20.0 537 Infiltration: 4,771 3,333 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = EA Equipment 0.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 X 1.27 X 70.81 X 1 4,005 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,168 Latent Gain 1.0 Occupants X 200 Btuh/occ. Btu/hr = 200 Occupants Infiltration: 4,771 X 1.27 X 70.81 X 0.00523 = 2,238 Air Sensible CFM ELA AW URLY LATENT HEAT GAIN f • • 1�1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Fishoff Residence 1 9/25/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 1,294.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 7 (NIM 0.0 X 21.5 + 8.0 X 37.2 = 298 7 (NIM 0.0 X 21.5 + 8.0 X 37.2 = 298 7 (NIM 0.0 X 21.5 + 8.0 X 37.2 =• 298 7 (NIM 0.0 X 21.5 + 8.0 X 37.2 = 298 7 (NM 0.01 X 21.5 + 8.0 X 37.2 = 298 11 (NIM 0.0 X 21.5 + 3.0 X 37.2 = 112 12 (NIM 0.0 X 21.5 + 20.0 X 33.4 = 669 X + X - X 1 +1 X - Page Total 2,270 Internal Gain Btu/hr Occu ants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.27 X 70.81 X 42 = 4,005 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,168 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4.771 X 1.27 X 70.81 X 0.00523 = 2,238 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,438 EnerqyPro 5.1 by Ene Soft User Number: 6712 RunCode: 2012-09-25716:19:52 ID: Pa a 39 of 39