Loading...
13-1484 (PLBG)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA; CALIFORNIA 92253. BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 13-000014 84 Property Address: 78515 VIA SONATA APN:" 646-290-009- - - Application description: PLUMBING Property Zoning: LOW DENSITY .RESIDENTIAL Application valuation: 1058 .Applicant: Architect or Engineer: v Owner: JAMES ROCKE 78515 VIA SONATA 'LA QUINTA, CA 92253- ( Contractor: CALIFORNIA DELTA MECHNI 6056 E. BASELINE RD, #1 MESA, AZ 85206 (866)692-5273 Lic-'No.: 811114 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date:11/21/13 CA I C NOV 212013 55 CITY OF LA QUINTA FINANCE DEPT. -------------------------------------------------- - _ LICENSED CONTRACTOR'S DECLARATION N ---------------------------------------------- - WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm underpenalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and P ofessionals Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: ASB , C10 , 16 L' a No.: 811114 - for by Section 3700 of the Labor Code, for the performanceof the work for which this permit is " Date: 1 , �3 Contractor.. issued. ' - I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor - _ Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: 1 hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier STATE FUND .Policy Number 1697823-11 following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to (.certify that; in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that: he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the Labor Cod hall fo with comply with those provisions. - that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: Date:.. G Applicant: (_) 1, as owner of the property, or my employeeswithwages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL • - Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. - one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). - APPLICANT ACKNOWLEDGEMENT 1 _ I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of .Building and Safety for a permit subject to the - - 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as result of this application, (_ I I am exempt under Sec. , B.&P.C. for this reason" the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City - - of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. ,. Date: Owner: - 2. Any permit issued as a result of this application becomes null and void if work is not commenced - - within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit to cancellation. ' I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the above information is correct. I agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). - city and county ordinances and state laws relating to building construction, and hereby authorize representatives ofthis county to enter upon the above-mentioned property f pectin purposes. - Lender's Name: - Date: �' ignature (Applicant or Agent):((c.J�"`^� Lender's Address: A LQPERM[1T Application Number 13-00001484 Permit . . PLUMBING 2013 Additional desc . Permit Fee 11.92 Plan Check Fee .00 Issue Date Valuation j. 0 Expiration Date 5/20/14 Qty Unit Charge Per Extension, 1.00 1-1.9200"EA PLBG WATER HEATER/VENT 11.92 ----------------------------------------------------------------------------- Special Notes and Comments WATER HEATER CHANGE OUT - 40GALLON/GAS [2008 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL. INSPECTION. 2010 CALIFORNIA BUILDING CODES. ---------------------------------------------------------------------------- Other Fees . . . ,. . . . . PERMIT ISSUANCE M/P/E - 90.57 PLAN CHECK, PLUMBING 7.15 Fee summary Charged Paid Credited Due Permit Fee Total 11.92 .00 .00 11.92 Plan Check Total .00 .00 .00 .00 Other Fee Total 97.72 .00 .00 97.72 Grand Total 10.9.64 .00 .00 109.64 LQPERMIT ' Qin # . .. Building Bt. Safety Division Permit # P -O: Box 1564,18-495 Calle Tampico /1�, La.Quinta, CA 92253 (760) 777-7012 • Building Permit Application and Tracking Sheet Project Address:IQS(rJ Via„ SO L'IJR• Owner's Name:.: A. P. Number. Address: Legal Description: City, ST, Zip: UL Ca, n.60. Contractor:ea Mechanical Ind. - • ` . <: -Telephone: Address: 605e E Baseline RoadProject-Description- Suite 155 City, ST, 'Lip: ' Telephone: . h'2Dn55'S .. �.. C''�•" City Lic. #•: 1oA ��j Arch., Eng., Designer. Address: City, ST, Zip: Telehone:Z' p :>> - . Construction Type: Cato Occupancy: State Lic. #: xAdd'n Alter Repair DemoaP Name of ContactPerson: •'1' Sq. Ft.: #Stories: #Units: Telephone # of Contact Person; (o(p . 73 Estimated•Value of Project: o5g APPLICANT: DO 140T WRITE BELOW THIS LINE # Submittal Rcq'd Recd TRACMG PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cities. Reviewed, ready for corrections Plan Check Deposit. Truss Cates. Called.Contact Person Plan Check Balance. Title 24 Cales. Plans picked up Construction Flood plain plan Plans resubmitted.'. Meehapical Grading pian rl,Rev'icw, ready for correctionstissue Electrical Subcontactor List Called Contact Person Plumbing Gront.Deed Plans picked up S,.M.I. ILOA. Approval Plans resubmitted Grading IN HOUSE:- '^' Review, ready 'for correctionvIssue Developer impact Fee Planning Approval Called Contact Person A:LP.P. Pub. Wks. Appr Date of permit issue school Fees Permit Fees STATE OF CALIFORNIA RESIDENTIAL ALTERATIONS CEC- CFA R -ALT (Revised 03/101 CALIFORNIA EN Prescriptive Certificate of Compliance: Residential C&M-ALT Residential Alterations age 1 of 7 Project Name: Climate Zone # I # of Stories General Information Site Address: Enforcement Agency: Date: Building Type ❑ Single Family ❑ Multi Family Circle the Front Orientation: N, E, S, W, or degrees Conditioned Floor Area (CFA): Project Type' ❑ Alterations ❑ Envelope ❑ Fenestration ❑ Roof ❑ HVAC Re lacement or Change Out ❑ Duct Replacement ❑ Water Heater NOTE: This form is not to be used for Newly Constructed Buildings or Additions Insulation Values For Opaque Surfaces (for Furring use the Mass and Furring Strips Construction table below) Assembly Alteration ❑ Opening of framed cavity alone— Alterations that involve the opening of the framed cavity of a wall, ceiling, or floor must install the mandatory minimum insulation value per §150 for the altered assembly. Fill in Columns A —C and enter mandatory insulation value in Column H. ❑ Replacement of entire assembly— Replacement of an entire wall, ceiling, or floor assembly requires the installation of Component Package- D insulation values in Table 151-C. Fill in Columns A —J. Opaque Surface Details.For the furred portioned of Mass Walls see Furring Strips Construction Table below. A B C D E F G H I J Proposed ee ore Standard Values From JA4 Table Walls From Reference Framing Thickness, Framed Continuous JA4 Proposed Tag/ ID' Assembly Name or T eZ Material Spacing, and Size or Other; U- factor° JA4 Table Cavity Numbers R -value Insulation R -.Value Assembly Row/Cola Assemblsy U -factor C,' y W Assembly j r c g •�°� o, 7 P. Final Mass Name or JA4 Table ' y d 7 E E o ° ' ' Assembly Thickness' T e' Numbe? ¢ > a x e id Q > U-factorb� Comment Note: For furred assemblies, accounting for Continuous Insulation R -value, see Page JA4-3 and Equation 4-1. For calculating furred walls use the Mass and Furring Constnrction table below. 1. For Tag/ID indicate the identification name that matches the building plans. 2. Indicate the Assembly Name or type: Roof/Ceiling, Walls, Floors, Slabs, Crawl Space, Doors and etc ... Indicate in column G the Frame material and Size: For Wood, Metal, Metal Buildings, Mass, enter 2x4, 2x6, or etc... see JA4 for other possible frame type assemblies. 3. Enter the thickness for mass in inches or Spacing between framing members enter; 16 "or 24 "OC; or Other for all other assembly description such as Concrete Sandwich Panel, Spandrel Panel, Logs, Straw Bale Panel and etc.... 4. Based on the Climate Zone; enter the equivalent U factor found in JA4 Table based on the R -Value from Table 151-B, C, or D 5. Enter the Table number that closely resembles the proposed assembly. 6. Enter the R -value that is being installed in the wall cavity or between the framing; otherwise, enter "0 ". 7. Enter the Continuous Insulation R -value for the proposed assembly; otherwise, enter "0". 8. Enter the row and column of the U factor value based on Column F Table Number and enter the Assembly U factor in Column J 9. The Proposed Assembly U factor, Column J, must be equal to or less than the Standard U factor in Column E to comply. Furr ing Strips Construction Table for Mass Walls Onl A B C D E F I C I H I J I K L M Proposed Properties of Masonry and Concrete Added Interior or Exterior Insulation Walls From Reference in Furring Space from Reference Joint Appendix Table 4.3.5, 4.3.6, 4.3.7 Joint Appendix Table 4.3.13 Q) V N ` ��,, V U `� C,' y W Assembly j r c g •�°� o, 7 P. Final Mass Name or JA4 Table ' y d 7 E E o ° ' ' Assembly Thickness' T e' Numbe? ¢ > a x e id Q > U-factorb� Comment Re;istrntionNtunber Re_xistratori"Date/Tinte HERSProvider ,Pon 2008 Residential Compliance Forms March 2010 G STATE OF CALIFORNIA RESIDENTIAL ALTERATIONS CEC- CF -1 R -ALT Revised 03110 CALIFORNIA ENERGY COMMISSION Prescriptive Certificate of Com liance: Residential CF -IR -ALT Residential Alterations Page 2 of 7 Project Name: Climate Zone # # of Stories Mass and Furring Strips Construction(footnotes) 1. Indicate the type of assembly to include; Hollow Unit Masonry Walls, Solid Unit Masonry, Solid Concrete Walls, Etc. Additional assemblies can befound Reference Joint Appendix J44. 2. This is the U -Factor based on the thickness of the assembly in inches. 3. The R -value of the insulation to be added on the interior or exterior of the assembly. 4. The Calculated R- Value is the R -value of the furred out section of the assembly. -6. The Final Assembly is calculated using Equation 4-2 or- Equation 4-4of the Reference Joint Appendix JA4. The equation is the inverse of Column added to Column L Column K is the inverse from column J. 7. Insert the calculated U factor value on to the Opaque Surface Details in Column J FENESTRATION PROPOSED AREAS ❑ Replacing window alone — Replacement windows shall meet the U -Factor and SHGC. Value requirements of Component Package D in Table 151-C. The Total Fenestration and West facing Area requirements are not applicable. ❑ Adding 50ft2 or less of window area — Newly installed windows .shall meet the U -Factor and SHGC Value requirements of Component Package D in Table 151-C ❑ Adding more than 50fe of window area — Newly installed windows shall meet the U -Factor and SHGC Value and the Fenestration Area requirements of Component Package D in Table 151-C. Complete the Altered Fenestration Allowed Area Table on Page 2 of the CF -1 R -ALT Orientation Fenestration Type and Frame (North, East, PropsedArea' Maximum Maximum NFRC or Default Window, Glass Door or Skylight) South, West) (ft' U -factor" SHGC" 1.4 Values 1. Fenestration area is the area of total glazedproduct (i.e. glass plus frame). Exception: When a door is less than 50% glass, the fenestration area may be the glass area phis a "2 inch frame" around the glass. 2. Enter value from Component Package D Requirements in Table 151-C. 3. Actual fenestration products installed and as indicated in CF -6R -ENV Form shall be equivalent to or have a lower U factor and/or a lower SHGC value than that specified on the CF -JR ALT Form. 4. Submit a completed WS -31? Form if a reduced SHGC is calculated with exterior shading. 5.If applicable at this stage enter "NFRC" or NFRC Certified windows or are CEC "Default - valuesfound in Table 116-A or B. ALTERED FENESTRATION ALLOWED AREAS (Complete if more than 50ft2 of fenestration is added) Ai B C D E F G CFA of Allowed Existing Allowed Entire % of Fenestration Area Fenestration Area Proposed Area 4 Dwelling CFA''' Area Removed Area Added A x B (E -D)'+ C Total Fenestration > Areae' ft2 West Fenestration Area (Required In >_ CZ's 2,4&7-15 RegistrAliom'1Vumber<• ,..,.....Regis"trationDa"te%Tiine: _. _ �FIERSProvider" 2008 Residential Compliance Forms March 2010 STATE OF CALIFORNIA RESIDENTIAL ALTERATIONS CEC-CFAR-ALT Revised 03/10 Prescriptive Certificate of Compliance: Residential -Residential Alterations ' Project Name: 1 a , CALIFORNIA ENERGY COMMISSION CF -1R -ALT Page 3 of 7 Climate Zone # # of Stories /.The Proposed West Fenestration Area includes West -sloping skylight area and any other skylight area with a pitch less• than 1:12. 2. Enter 20% when no West orientation restriction or 15% when West fenestration is being installed in Climate Zones 2, 4, & 7-15. Note that the' maximum allowed fenestration can only be 5% of the CFA as indicated in Column F. Column G must be equal to or less than Column F 3. In climate zones 2, 4, 7-15, no more than 5% of the CFA is allowed for west facing glazing. 4. Existing Fenestration area must be counted toward the maximum allowed 15% or 20% of the whole building and calculated in. Column G. The Proposed Area must be less than or equal to Column F. 5. Enter the fenestration removed as part of the alteration if any in column D. .1 STATE OF CALIFORNIA RESIDENTIAL ALTERATIONS CEC- CF -1R -ALT Revised 03/10 Prescri tive Certificate of Compliance: Residential Residential Alterations Project Name: CALIFORNIA ENERGY COMMISSION CF -IR -ALT Pa e4df7 Climate Zone # # of Stories ROOFING PRODUCTS (COOL ROOFS) §151(t)12, When the area of exterior roof surface to be replaced exceeds more than 50% of the existing roof area, or more than 1,000 f , whichever is less, the new roofing area must meet the roofing product "Cool Roof' requirements of §152(b)IHi, 152(b)1Hii, or 152(b)IHiii. Check applicable alternative or exception below if the roof alteration is exempt from the roofing product "Cool Roof' requirements. Note: If any one of the alternatives or exception below is checked, the Aged Solar Reflectance and Thermal Emittance requirements for roofing products in §118(1) are not applicable. Do not fill table below. . ❑ Cool Roofs Not Required in Climate Zones 1-12, 14, and 16 with a Low Sloped. Less or 2:12 pitch. ❑Cool Roofs Not Required in Climate Zones 1 through 9 and 16 with a Steep -Sloped Roofs (pitch greater than 2:12) and product unit weight less than 5lb/ft2. Alternatives to §152(b)1Hi and §152(b)Hii, Steep -slope roof (pitch > 2:12) - - ❑ Insulation with'a thermal resistance of at least 0.85 heft •°FBtu or at least a 3/4 inch air -space is added to the roof deck over an attic; or / ❑ Existing ducts in the attic are insulated and sealed according to §151(f)10; or ❑ In climate zones 10, 12 and 13, with 1 ftZ of free ventilation area of attic ventilation for every 150 ft2 of attic floor area, and where at least 30 percent of the free ventilation area is within 2 feet veitical distance of the roof ridge; or ❑ Building has at least R-30 ceiling insulation; or , ❑ Building has radiant barrier in the attic meeting the requirements of §151(02; or ❑ Building has no ducts in the attic; or ❑ In climate zones 10, 11, 13 and 14, R-3 or greater roof deck insulation above vented attic. Exception to §152(b)1Hiii, Low -slope roof (pitch <_ 2:12) - ❑ Building has no ducts in the attic. J - Other Exceptions ` ❑ Roofing area covered by building integrated; photovoltaic panels and solar thermalpanels are exempt from the below .Cool Roof criteria. ❑ Roof constructions that have thermal mass over the roof membrane with at least 25 Ib/fie is exempt from the below Cool Roof criteria. Note: If no CRRC-1 label is available, this compliance method cannot be used, use the Performance Approach to show compliance, otherwise, Check the applicable box below if Exempt from the Roofing Products "Cool Roof' Re uirement: Roof Slope Product Weight Product Aged Solar Thermal CRRC Product ID Number[ 2:12. > 2:12 < 5lb/fig >_ 51b/fi2 Type Z Reflectance 3,4 Emittance SRI5 _< ❑ ❑ ❑ 0 ❑4 ❑ 11. ❑ ❑ • ❑4 w ❑ ❑ ❑ ❑' ❑4 ❑ ❑ ❑ ❑' - EV c / 11 . ❑ 11, 11❑4 1. The CRRC Product ID Number'can be obtained from the Cool Roof Rating Council's Rated Product Director), at www.coolroo s.or /products/search.php 2. Indicate the type of product is being used for the rooftop, i.e. single ply roof, asphalt roof, metal roof, etc. 3. If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value from the same - directory and use the equation (0.2+0.7(pi„hint — 0.2) to obtain a calculated aged value.. Where p is the Initial Solar Reflectance. 4. Check box if the Aged Reflectance is a calculated value using the equation above. 5. Calculate the SRI value by using the SRI- Worksheet at h_ tip•//www.ener;ey.ca..gotdlitle24/and enter the resulting value in the SRI Column above and attach acop); of the SRI- Worksheet to the CF -JR. o apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage ' recommended by the coatings manufacturer and meet minimum performance requirements listed in § 1 I8(i)4. Select the applicable coating: FOAhuninurn-Pigmented Asphalt Roof Coating TO Cement -Based Roof Coating ❑ Other 4. Registration:Num6er:W57Regis tration'Date/Timei HERSRro"viler .: '2008 Residential Compliance Forms March 2010 STATE OF CALIFORNIA RESIDENTIAL ALTERATIONS CEC-CF-IR-ALT Revised 03/10 CALIFORNIA ENERGY COMMISSION Prescriptive Certificate of Compliance: Residential CF -IR -ALT Residential Alterations (Page 5 of 7 Project _N�e: / ! Climate Zone # # of Stories HVAC SYSTEMS - HEATING List water heaters and boilers for both domestic hot water (DHW) heaters and hydronic space heating. Individual dwelling DHW heaters must be gas or propane fired. Hot water pipe insulation from the DHW heater to the kitchen (s) and on all underground hot water pipes is required in all Minimum Duct or Piping Configuration Heating Equipment Efficiency ; Distribution Insulation Thermostat (Central, Split, Type and Capacity" 2,3 AFUE or HSPF Type and Location R -Value Type Space, Package or H dronic (Standard, Recirculating)2 System Capacity (gal) Thermal Efficiency R-Value3 S015-5 1. Indicate Heating Type (Central Furnace, Wall Furnace, Heat pump, Boiler, Electric Resistance, etc.) 2. Electric resistance heating is allowed only in Component Package C, or except where electric heating is supplemental (i.e., if total capacity < 2 KW or 7,000 Btu/hr electric heating is controlled by a time -limiting device not exceeding 30 minutes). See §151(b)3 exception. 3. Refer to the HERS Verification section on Page 4 of the CF -IR -ALT Form for additional requirements and check applicable bores. 4. Indicate Type or Location (Ducts, Hydronic in Floor, Radiators, etc) HVAC SYSTEMS - COOLING Minimum 1. Indicate Type (Storage Gas, Heat Pump, Instantaneous, etc.) 2. Recirculating systems serving multiple dwelling units shall meet the recirculation requirements of §150(n). The Prescriptive requirements do Efficiency Duct or Piping Configuration Cooling Equipment (SEER/EER or Distribution Insulation Thermostat (Central, Split, Type and Capacity' .2 COP) Type and Location R -Value Type Space, Package or H dronic 1. Indicate Cooling Type (A/C, Heat pump, Evap. Cooling, etc) 2. Refer to the HERS Verification section on Page 4 of the CF -IR -ALT Form for additional requirements and check applicable boxes. 3. Indicate Type or Location(Ducts, H dronic in Floor, Radiators, etc. WATER HEATING List water heaters and boilers for both domestic hot water (DHW) heaters and hydronic space heating. Individual dwelling DHW heaters must be gas or propane fired. Hot water pipe insulation from the DHW heater to the kitchen (s) and on all underground hot water pipes is required in all component packages in all climate zones. External Tank Water Heater Type/Fuel Distribution Type Number In Tank Energy Factor or Insulation Typen (Standard, Recirculating)2 System Capacity (gal) Thermal Efficiency R-Value3 S015-5 1 1. Indicate Type (Storage Gas, Heat Pump, Instantaneous, etc.) 2. Recirculating systems serving multiple dwelling units shall meet the recirculation requirements of §150(n). The Prescriptive requirements do not allow the installation of a recirculating water heating system for single dwelling units. 3. The external water heating tank and i es shall be insulated to meet the requirements o §150 ). SPECIAL FEATURES The enforcement agency should pay special attention to the Special Features specified in this checklist below. These items may require written justification and documentation and special verification. NEW ROOF ASSEMBLY - Radiant Barrier The radiant barrier re uirement of § 151 (92 does not apply to roof alterations. Slab Edge (Perimeter) Insulation ❑ YES ❑ NO YES: In Climate Zone 16 in Component Packages D, R-7 insulation is required. Heated Slab Insulation ❑ YES ❑ NO YES: Slab edge insulation required for all heated slabs in all Climate Zones. See details in Table 118-A of the standards. Raised Slab Insulation ❑ YES ❑ NO YES: In Climate Zones 1, 2, 11, 13, 14 & 16, R-8 insulation is required; in Climate Zones 12 & 15, R4 is required under component Package D. Registrdtion Nirnrlier.' Registration Date/Tinne< , HERS`Providerrr 2008 Residential Compliance Forms March 2010 STATE OF CALIFORNIA RESIDENTIAL ALTERATIONS CEC-CF-IR-ALT Revised 03/10 CALIFORNIA ENERGY COMMISSION Prescriptive Certificate of Compliance: Residential CF -IR -ALT Residential Alterations Page 6 of 7 Project Name:/ Climate Zone # # of Stories 7A.Sl S 11;A f01 Thermal Mass To obtain Compliance Credit for the installation of thermal mass, use the Performance Approach. 1, HERS VERIFICATION SUMMARY The enforcement agency should pay special attention to the HERS Measures specified in this checklist below. A completed and signed CF -41? Form for all the measures specified shall be submitted to the building inspector before final inspection. Duct Sealing & Testing HERS verification is required for this measure. ❑ YES ❑ NO YES: In Climate Zones 2 and 9-16, if more than 40 linear feet of new or replacement ducts are installed in unconditioned space, the ducts are to be sealed per § 152(b)1Dii and the newly installed ducts are to be insulated per § 15l(f)l0. ❑ EXCEPTION: Existing duct systems that are extended, which are constructed, insulated or sealed with asbestos. ❑ YES ❑ NO YES: In Climate Zones 2 and 9-16, if the existing space -conditioning system (HVAC equipment and ducting) is replaced, the ducts are to be sealed per § 152(b)1 Di. ❑ YES ❑ NO YES: In Climate Zones 2 and 9-16, if the existing HVAC equipment is replaced (including the replacement of the air handler, outdoor condensing unit of a split system, cooling or heating coil, or the furnace heat exchanger) the ducts are to be sealed per §152(b)IE. ❑ EXCEPTION: Duct systems that are documented to have been previously sealed confirmed through HERS verification in accordance with procedures in the Reference Residential Appendix RA3. ❑ EXCEPTION: Duct systems with less than 40 linear feet in unconditioned space. ❑ EXCEPTION: Existing ducts stems constructed, insulated or sealed with asbestos. Refrigerant Charge - Split System HERS verification is required for this measure. ❑ YES ❑ NO YES: In Climate Zones 2 and 8-15, when the existing HVAC equipment is replaced (including the replacement of the air handler, outdoor condensing unit of a split system A/C or heat pump, cooling or heating coil, or the fumace heat exchanger) a refrigerant charge measurement shall be verified per 152(b)1F. Central Fan Integrated (CFI) Ventilation System and Fan Watt Draw The ventilation requirements of § 150(o) do not apply to existing residential homes. Ducted Split Systems - Air Conditioners and Heat Pumps: Airflow HERS verification is required for this measure. ❑ YES ❑ NO YES: In Climate Zones 10 through 15, when the existing-, space -conditioning system (HVAC equipment and ducting) is, replaced, the airflow and fan watt draw shall be verified per § 152(b)1Ci to meet the requirements of § 151(f)7B. Documentation Author's Declaration Statement • I certify that this Certificate of Compliance documentation is accurate and complete. Name: Signature: Company: Date: Address: If Applicable ❑ CEA or ❑ CEPE (Certification #): City/State/Zip: Phone: Responsible Building Designer's Declaration Statement • I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. • I certify that the energy features and performance specifications for the building design identified on this Certificate of Compliance conform to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations. • The building design features identified on this Certificate of Compliance are consistent with the information provided to document this building design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Registration:lVumiier. , . , RegistrdtioroDateLTime' FIERSProviderf 2008 Residential Compliance Forms March 2010 STATE OF CALIFORNIA r RESIDENTIAL ALTERATIONS CEC- CF -IR -ALT Revised 03/10 CALIFORNIA ENERGY COMMISSION Prescriptive Certificate of Com liance: Residential CF -IR -ALT Residential Alterations • (Page 7 of 7 Project Name:. Climate Zone # # of Stories Name�+am 013,0 T 1 V� Signature: , Compan : D�, � � Date: I / Address: v� License: SHIN... H I / � . 1 City/State/Zip: Spry _M l/a C CA .6� 1 7.7 Phone: l g�� r�'92-5273 For assistance or questions rVgarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300. Y 1 Registration'Number..a, .. R'egistration�Dat'e/Trine::° •, • . ,: - ,WFIERSTrovider: 2008 Residential Compliance Forms March 2010 r