Loading...
12-0604 (AR)4 P.O. BOX 1504 VOICE (760) 777-7012 78-495 CALLE TAMPIC0 FAX (760) 777-701.1 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING .PERMIT D� d D e: 7 /12 Application Number: 12-00000604• Owner: Property Address: 53791 VIA STRADA T&W. BALLARD FAMILY TRUST APN: 772-540-042- - 67 CANYON CREEK )i j� ) 2011 Application description: ADDITION - RESIDENTIAL IRVINE, CA 92603 Property Zoning: LOW DENSITY RESIDENTIAL CIT1roFl1►QuINT Application valuation: 15000 < FINA14CE DEPT. t \ - Contractor: Applicant: Architect or Engineer: SUNROSE CORPORATION 40101 MONTEREY AVE STE B1-214 r RANCHO MIRAGE, CA 92270 • - ,, rl� - (760)773-6633 - •. Lia. No.: 533670 ; 'Y LICENSED CONTRACTOR'S DECLARATION_ WORKER'S COMPENSATION DECLARATION - I hereby affirm under penalty of perjury that I am licensed under' provisions of Chapter.9 (commencing with I hereby affirm under penalty of perjury -one of the following declarations: Section 7000) of Division 3 of the Business and Pr fessionals Code; and my License is in full force and effect. - : - I'have and will 'maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: B - icense No.: 533670 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is f/ /ir issued. /o.te..7J� ! ontra r. _� Y_ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor yy Code, for the performance of the work for which this permit is issued. My workers' compensation OWN -RJ8UILDER DECLARATION - insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the - Carrier .STATE FUND - Policy Number 1948056-2012 following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to r _ I certify that, in the. performance of the work for which this permit is issued, I shall not employ any :. construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the •applicantfor-the _ person in any manner so' as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State - and agree that, if I should become sub*o the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000),of Division 3 of the Business and Professions Code) or - - 3700 of the Labor Cod I shall forthwith-eem ly with those provisions. w - • . that he or she isexempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by .L �� any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).- Date: _ // �� ppli ca(tt: (_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and - the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAI URE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIESANDCIVIL FINES UP TO ONE HUNDRED THOUSAND. and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000).. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN - improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.. _ one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). - - APPLICANT ACKNOWLEDGEMENT (_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. - IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the - 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of - conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1 - Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.)•_ whose benefit work is performed under or pursuant.to any permit issued as a result of this application,. • I—) I am exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City " Date: Owner: CONSTRUCTION' LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). - t Lender's Name:. _ Lender's Address: LQPERMIT of La Quinta, its officers, agents and "employees for any act or omission related to the work being performed under or following issuance of this permit. r 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. " I certify that I have read this application and state that the above information is correct. I agree to comply with all - city and county ordinances and state laws relating to building construc • and her authorize representatives of this�7ounty to enter upon the above-mentioneedd pr for inspectio�l purpo S. te: ( gnature (Applicant or Aoen' t): Application Number . . . . . 12-00000604 Structure Information Construction Type . . . . TYPE V, UNPROTECTED Occupancy Type. . DWELLG/LODGING/CONG <=10 Other struct info . . . . . CODE EDITION 2010 # BEDROOMS .00 PATIO SQ FTG 544.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . .162.00 Plan Check Fee 105.30 Issue Date . . . . Valuation . . . . 15000 - Expiration Date 1/16/13 - Qty Unit Charge Per Extension - BASE FEE- 45.00 13.00 9.0000 THOU BLDG 2,001-25,000 117.00 Permit ELEC-MISCELLANEOUS Additional desc . Permit'Fee . . 23.25 Plan Check Fee 5.81 Issue Date Valuation., 0 Expiration Date 1/16/13 Qty Unit Charge Per Extension BASE FEE 15.00 11.00 .7500'PER ELEC DEVICE/FIXTURE 1ST 20 8..25 ---------------------------------------------------------------------------- Special Notes and Comments 544 SF ENGINEERED COVERED PATIO ADDITION AND SLIDING GLASS DOOR REMODEL AT REAR ELEVATION PER.ENGINEERED DESIGN.2010 CODES. ENGINEER: REZA ASHGAPOUR 67613 ---------- -------------- Other Fees --- --- - . . BLDG STDS ADMIN (SB1473) 1.00 ENERGY REVIEW.FEE 10.53 HOURLY PLAN CHECK 245:00 `STRONG MOTION (SMI) - RES 1.50 Fee summary` Charged Paid Credited Due Permit Fee Total 185.25 .00 .00 185.25 Plan Check Total 111.11 .00 .00 111.11 Other Fee Total 258.03 .00 .00 258.03 Grand Total 554.39 .00 :00 554.39 LQPERMIT Bln.fl I " City. Of Lei Quinta Building 8L Safety Division P.O. Box 1504,78-495 Calle Tampico La.Quinta, CA 92253 -:(760) 777-7012 Building Permit Applicadon•and Tracking Sheet Permit# Project Address: 3 _ Owner's Name:. A. P. Number 7 f ,Z -- �tD O Z Address: 5.3. %4l v �l( Legal Description: City, ST, Zip. Contractor.S r " v XA Telephone: Address: D p p/ cjectDescription: City, $T, Zip: 44 Guli/r�r I { � f 1 Z 70 -5Pee- ;,q, eo t. e- l ,/ . Telephone: State Lic. 4: 6'j3(e*7 D City Lic. C . t�frio to ._ S � . Arch., Engr., Designer. //- ,/COVl!✓ic Address: City., ST. Zip: Telephone: State Lia #: : <;, Construction Type: • Occupancy: Project type (circle one): New Add'n. Alter Repair Demo Name of Contact Person: �� a l� �.. /(�(�r Sq, Ft; # Stories:# Unity: Telephone # of Contact Person: Estimated Value of Project ^ QD 0 APPLICANT: DO NOT WRITE BELOW THIS UNE P Submittal Rcq'd Recd TRACKING PERMIT FEES Plan Sets 3 Plan Check submitted 31 A P-- Amount S"ctural Cases. a Reviewed, ready fo ro actions Plan Check Deposit. . Truss Cates. - Called Contact P Plan Check Balance. Title 24 Calm / Plans picked up 6 `� Construction Flood plain plan Pians resubmitted.' . l Mecharilcal Giading plan 2'' Review, ready for correctiotVm, 777 Electrical Subcontactor list Called Contact Person I `Plumbing Grant Deed Pians picked up MI. ILO.A. Approval Plans resubmitted Grading IN $OUSE:' ''" Review, ready for eorrectionsRssue Developer Impact Fee Planning Approval Called Contact Person Pub. Wks. Appr Date of permit issue School Fees . Total Permit Fees. d*4•. 7/1 i2AP • ; r T May 15, 2012 y Mr. and Mrs. Ballard 620 Newport Center Drive, 8`h Floor, Newport Beach, CA 92660 f RE: Ballard/Lot 258 at 53791 Via Strada Revisions to Approved Plans #3 Dear Mr. and Mrs. Ballard, - r The Hideaway Design Review Committee (DRC) reviewed and approved the revisions presented with regard to the architectural remodel at your home on Via Strada. Landscape plans are still required and a color sample should be provided in the field, adjacent to the existing stone, for final approval of the color modification. Please contact Brook Marshall at (760) 219-8057 or by email at with any questions. Sincerely, Hideaway Design Review'Committee- cc: Mike Tuvell r DRC File BUILDING ENERGY ANALYSIS REPORT PROJECT: Ballard, Residence . 53-791 Via Strada La Quinta, CA 9.2253 + Project Designer: Studio Linea 57-770 Black Diamond La Quinta, CA 92253 (760)_899-3368 Report Prepared by: Jon Scott .. .Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 ` (760) 200-4780 JUN 29 2012 By - .,Job Number: ITV OF LA QUINTA BUILDING & SAFETY DEPT. . APPROVED FOR ONSTRUCTION _ Date: 6/27/2012 [DATE l2 -(PC The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the, Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 7y EnergySoft User Number. 6712r RunCode: 2012-06-27T08:45:32 /D: r Alhk EnergyPro 5.1 by EnergySoft Job Number. ID: User Number: 6712 • C] • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Ballard Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 6/27/2012 Project Address 53-791 Via Strada La Quinta California Energy Cliniate'Zone CA Climate Zone 15 I Total Cond. Floor Area' 7,079 Addition 0 # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-19 2,211 Existing Wall Wood Framed R-13 7,219 Existing Door Opaque Door None 40 Existing Slab Unheated Slab -on -Grade None 5,961 Perim = 280' Existing Floor Wood Framed w/o Crawl Space R-19 790 Existing FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Front (NE) 251.0 0.550 0.55 none none Bug Screen Existing Left (SE) 140.0 0.550 0.55 none none Bug Screen Existing Rear (SW) 206.6 0.550 0.55 none none Bug Screen Existing Rear (SlAq 282.9 0.550 0.55 none none Bug Screen Removed Rear (SM 220.0 0.400 0.35 none none Bug Screen New Right (Nblq 83.0 0.550 0.55 none _ none Bug Screen Existing HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 3 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status Existing HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-06-27708:45:32 ID: Page 3 of 12 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Ballard Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 6/27/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnemyPro 5.1 by EnemySoft User Number.- 6712 RunCode: 2012-06-27708:45:32 - ID: Page 4 of 12 r, • • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Ballard Residence ❑ Multi Family m Existing+ Addition/Alteration 6/27/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 6.74 6.48 0.25 Space Cooling 105.26 93.74 11.52 Fans 23.00 20.54 2.46 Domestic Hot Water 4.51 4.51 0.00 Pumps 0.00 0.00 0.00 Totals 139.51 125.2 7. ' 14.24 Percent Better Than Standard: 10.2% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NE) 50 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 11.00 (NE) 2,280 251 Fuel Available at Site: : Natural Gas (SE) 1,800 140 Raised Floor Area: 790 (SK9 2,280 427 Slab on Grade Area: 5,961. (NW) 1,800 83 Average Ceiling Height: 11.7 Roof 2,211 0 Fenestration Average U -Factor: 0.51 TOTAL: 901 . Average SHGC: 0.50 Fenestration/CFA Ratio: 12.7% REMARKS The Hideaway Country Club STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed. to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complet Documentation Author Company Scott Design and Title 24, Inc, 61,12712012 Address 77-085 Michigan Drive Name Jon Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. A + Designer or Owner (per Business & Professions Code) Company Studio Linea Address 57-770 Black Diamond Name Mike Hanes f City/State/Zip La Quinta, CA 92253 Phone (760) 899-3368. Signed Lice se # Date EnemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2012-06-27708:45:32 ID: Page 5 of 12 0 0 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Ballard Residence Building Type m Single Family 0 Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1612712012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,093 0.049 R-19 0 20 Existing 4.2.1-A4 Altered Res Wall 909 0.102 0-13 50 90 Existin 4.3.1-A3 Altered Res Door 20 0.500 None '50 80 Existing' 4.5.1-A4 Altered Res Door 20 0.'500 None 50 90 Existing4.5:1-A4 ' Altered Res Wall 760 0.102 'R-13 140 90 Existing 4.3.1-A3 Altered Res Wall 749 0.1b2 R-13 230 90 Existin 4.3.1-A3 Altered Res Wall 853 0.102 R-13 320 90 Existing 4.3.1-A3 Altered Res Slab 5,961 0.730 None 0 180 Existing 4.4.7-A1 Altered Res Roof 1,118 0.049 0-19 0 20 Existing 4.2.1-A4 2nd Floor Wall 1,080 0.102 R-13 50 90 Existing4.3.1-A3 2nd Floor Wall 900 0.102 R-13 140 90 Existing 4.3.1-A3 2nd Floor Wall 1,104 0.102 R-13 230 90 Existing4.3.1-A3 2nd Floor Wall 864 0.102 R-13 320 90 Existing4.3.1-A3 2nd Floor Floor 790 0.048 R-19 0 180 Ext stin 4.4.2-A4 2nd Floor FENESTRATION SURFACE DETAILS D Type Area LI -Factor' SHGC Azm Status GlazingType Location/Comments 1 Window 25.0 0.550 Default 0.55 Default 50 Existing Double Non Metal tint Altered Res 2 1.5 Window 64.0 0.550 Default 0.55 Default 50 Existing Double Non Metal tint Altered Res 3 Window 32.0 0.550 Default 0.55 Default .50 Existin' Double No Metal tint Altered Res 4 Window 150 0.550 Default 0.55 Default 50 Existing Double Non Metal tint Altered Res Window 1 15.0 0.550 Default 0.55 'Default 50 Existing Double Non Metal tint Altered Res 6 Window 36.0 0.550 Default 0.55 Default 50 Existing Double Non Metal tint Altered Res 7 Window 4.0 0.550 Default 0.55 Default 50 Existing Double Non Metal tint Altered Res 8 Window 17.5 6.550 Default 0.55 Default 140 Existing Double Non Metal tint Altered Res 9 Window 14.5 0.550 Default 0.55 Default 140 Existing Double Non Metal tint Altered Res 10 Window 36.0 0.550 Default 0.55 Default 140 Existing Double Non Metal tint Altered Res 11 Window 24.0 0.550 Default 0.55 Default 140 Existing Double Non Metal tint Altered Res 12 Window 32.0 0.550 Default 0.55 Default 140 Existing Double Non Metal tint Altered Res 13 Window 16.6 0.550 Default 0.55 Default 140 Existing Double Non Metal tint 'Altered Res 14 Window 36.0 0.550'Default 0.55 Default 230 Existing Double Non Metal tint Altered Res 15 Window 4.0 0.550 Default 0.55 1 Default 1 230 Existing Double Non Metal tint Altered Res 16 Window 16.5 0.550 Default 1 0.55 Default 1 230 Existing Double Non Metal tint Altered Res (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Len H t LEA I RExt Dist I Len Ri ht in H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 JBug Screen 0.76 16 JBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-06-27T08:45:32 ID: Page 6 of 12 0 • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Ballard Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 6/27/2012 OPAQUE SURFACE DETAILS Surface q- Insulation Joint Appendix ape Area Factor Cavity Exterior Frame Interior Frame' Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor SHGC Azm Status GlazingType Location/Comments 17 Window 16.5 0.550 Default 0.55 Default 230 Existing Double Non Metal tint Altered Res 18 Window 16.5 0.550 Default 0.55 Default 230 Existing Double Non Meta) tint Altered Res 19 Window 17.1 0.550 Default 0.55 Default 230 Existing Double Non Metal tint Altered Res 20 Window 240.0 0.550 Default 0.55 Default 230 Removed Double Non Metal tint Altered Res 21 Window L 14.3 0.550 Default 6.55 Default 230 Removed Double Non Metal tint Altered Res 22 Window 14.3 0.550 1 Default 0.55 Default 230 Removed Double Non Metal tint Altered Res 23 Window 14.3 0.550 Default 0.55 Default 230 Removed Double Non Metal tint Altered Res 24 Window 220.0 0.400 NFRC 0.35 NFRC 230 New ' Double Non Metal tint. Altered Res 25 Window 64.0 0.550 Default 0.55 Default 230 Existing Double Non Metal tint Altered Res 26 Window 16.0 0.550 Default 0.55 Default 320 Existing Double Non Metal tint Altered Res 27 Window 4.0 0.550 Default 0.55 Default 320 Existing Double Non Metal tint Altered Res 28 Window 4.0 0.550 Default 0.55 Default 320 Existing 'Double Non Metal tint Altered Res 29 Window 4.0 0.550 Default 0.55 Default 320 Ex -i -sting Double Non Metal tint Altered Res 30 Window 4.0 0.550 Default 0.55 Default 320 Existing Double Non Metal tint Altered Res 31 Window 15.0 0.550 Default T 0.55 Default 3201 Existing Double Non Metal tint Altered Res 32 Window 48.0 0.550 Default I 0.55 Default 501 Existing I Double Non Metal tint 2nd Floor (1) U -Factor Type: ' 2 SHGC Type: 116-A = Default'Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len H t LExt REA Dist Len Right Fin H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Buo Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 JBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number.- 6712 RunCode: 2012-06-27708:45:32 ID: Pae 7 of 12 .0 • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Ballard Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family- m Existing+ Addition/Alteration Date 1612712012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor - SHGC Azm Status Glazing TXpe Location/Comments 33 Window 4.0 . 0.550 Default 0.55 Default 50 Existing Double Non Metal tint 2nd Floor 34 Window 4.0 0.550 Default 0.55 Default 50 Existing Double Non Metal tint 2nd Floor 35 Window 4.0 0.550 Default 0.55 Default 50 Existing Double Non Metal tint 2nd Floor 36 Window 36.0 0.550 Default 0.55 Default 230 Existing Double Non Metal tint 2nd Floor 37 Window 36.0 0.550 Default 0.55 Default 320 Existing Double Non Metal tint 2nd Floor (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Cive hang Left Fin Right in ID Exterior Shade Type SHGC H t Wd Len Hat LExt RExt Dist Len Hat Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number 6712 RunCode: 2012-06-27T08:45:32 ID: Page 8 of 12 0 r� • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Ballard Residence Building Type ® Single Family 13Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 1612712012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New' 'Existing Altered Removed Volume Year Built Existing HVAC Altered Res 5,961 71,532 2000 2pd Floor 1,118 1 1,18 0 '2000 Totals 01 7,0791 01 0 HVAC SYSTEMS ' System Name Oty. Heating T' a Min. Eff. Cooling TXpe Min. Eff. Thermostat Type Status Existing HVAC 3 Central Fu'mace 80% AFUE Split Air Conditioner 13.0 SEER Setback '' Existing HVAC DISTRIBUTION ' System Name Heating Duct Cooling Duct Location R -Value ' Ducts Tested? Status Existing HVAC Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name O . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank InsuL,R- Value Status Standard 50 ga or Less 1 Small Gas All Pipes Ins 40,000 50 0.61 n/a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 _ o m - N a c System Name Pipe Length Pipe Diameter Insul. Thick. aty. FHP Plenum Outside Buried EneroyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-06-27708:45:32 ID: Page 9 of 12 4 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Date Ballard Residence I 1 1 6/27/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated r u 4 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Date Ballard Residence I 1 1 6/27/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans.. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain ` Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -IR Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed desi n,labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent LI -factor. 4150(f): Air retarding wrap is tested labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -IR Form. 4150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission.. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of 113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces,. household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE; SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water,heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. . §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatina sections of hot water pipes are insulated per Standards Table 150-B. §1506)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §150(i)3A: Insulation is protect6d from damage, including that due to sunlight, moisture equipment maintenance and wind. §1 506)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. ` 150(j)4: Solar water-heatin 's stems and/or collectors are certified b .the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 6712: RunCode: 2012-0&27708:45:32 ID: Page 10 of 12 • C MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Ballard Residence 1612712012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §150(m)10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heatincl ora pilot li ht. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. §150(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150(p). Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified b 150(k)2. 150(k)3: The wattage of permanentlyinstalled luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 1 50 k . §150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 f12 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a marival-on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro5.1 by EnergySoff User Number. 6712 RunCode: 2012-06-27708:45:32 ID: Page 11 of 12 r- LJ C MANDATORY MEASURES SUMMARY: Residential_ Pae 3 of 3 MF -1 R Project Name Date Ballard Residence 1612712012 §150(k)10: Permanently installed luminaires in bathrooms, attached and, detached garages, laundry rooms, closets and utility rooms shall be, high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by,a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. - §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with,the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances; balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionlto §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). - §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. t r i i EnergyPro 5.1 by EnergySolf User Number: 6712 RunCode: 2012-06-27708:45:32 ID: Page 12 of 12