07-2029 (SFD)rr• - - P.O. BOX 1504 78-495 CALLE TAMPICO, LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: `07_ -00 -002029 - Owner: Property Address: 53664 VIA STRADA, STEVE KESSLER APN: 772-540-046- - - J 76-906 TOMAHAWK RUN Application description: DWELLING - SINGLE FAMILY DETACHED INDIAN WELLS_CA CA 92210 Property Zoning: LOW DENSITY RESIDENTIAL Other struct info Application valuation: 443700 Contractor: Applicant: Architect or Engineer: Owner VOICE (760) 777-7012 - FAX (760) 777-7011 INSPECTIONS (760) 777-7153 C DITION 2 01/2,005 of "49 Date: 10/15/07 LQPERI111T � w--------- -------------=---------------------------------------------7-------------------_ft . LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATIO I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. I have and will maintain a certificate of consent to self -insure forworkers' compensa on, as provided License Class: License No.: _ for by Section 3700 of the Labor Code, for the performance of the work for which "this permit is - issued. - Date: Contractor: - _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor - r Code, for the performance of the work for which this permit is issued. My workers' compensation - - OWNER -BUILDER DECLARATION insurance carrier and policy number are: hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier 3 .PA Policy Number NO - ' following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to I certify that, in the perfor nce f the work for which this permit,js issued, I shall not employ any - construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner oast become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State _ and agree that, if I s / ould b ome subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the abor ode, I all forthwith comply with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by ` any applicant for a permit subjects the applicant to a civilpenalty of not more than five hundred dollars ($500).: ate: sY) a Applicant: ' (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and - the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS J$1 00,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN -improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. " one year of completion, the owner -builder will have the burden of proving that he or she did not build or L improve for the purpose of sale.). ` ' - - APPLICANT ACKNOWLEDGEMENT ' () I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application isherebymade to the Director of Building and Safety for a permit subject to the , ' 7044, Business and Professions Code: Th on actors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon nd w o contracts for the projects with a contractor(s) licensed 1 . Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State Lic se Law whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_ 1 I am exempt under Sec. , B.& .C. for t s reason ". the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City - of La Quinta, its officers, agents and employees for any act or omission related to the work being p, u performed under or following issuance of this permit. O ate: 'i ner- 2. Any permit issued as a result of this application beco s null and void if work is not commenced - within 180 days from date of issuance of such per i or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit to cancellation. ' I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the - 1 certify that I have.read this application and state th4theov nformation is correct. Iagree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). city and county ordinances and state taws relating tnstruction, and hereby authorize representatives Lender's Name: . - of this county to enter upontheove-mentioned prspection purposes. t S' ature (Applicant or Agent): . Lender's Address: LQPERI111T Application Number 07-00002029 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 1843.50 Plan Check Fee 1198.28 Issue Date Valuation . . . 443700 Expiration Date 4/12/08 Qty Unit Charge Per Extension BASE FEE 639.50 344.00 3.5000 THOU BLDG 100,001-500,000 1204.00 . Permit . . MECHANICAL Additional desc.. Permit Fee . . 126.00 Plan Check Fee : '31.50 Issue Date . . Valuation 0 Expiration Date '. 4/12/08.. Qty Unit Charge Per Extension BASE FEE 15.00 4:009.0000 EA MECH FURNACE <=10.OK 36.00 4.00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 5.00 6.5000 EA MECH VENT FAN 32.50 1.00 6.5000 EA MECH EXHAUST HOOD - 6.50 Permit . . . ELEC.-NEW RESIDENTIAL Additional desc . Permit Fee 228.84; Plan Check Fee 57.21 Issue Date Valuation 0 Expiration Date 4/12/08 Qty Unit Charge Per Extension BASE -FEE 15.00. 5180:00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 181.30 877.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 17.54 1.00 15.0000 EA 'ELEC TEMPORARY POWER POLE 15.00 Permit . . . PLUMBING Additional desc Permit Fee . . . . '. 219.00 Plan Check Fee 54.75 Issue Date : . . . Valuation . . . . 0 Expiration Date 4/12/08 Qty Unit Charge Per Extension BASE FEE 15.00 .23.00 6.0000 EA PLB FIXTURE 138.00 LQPERMIT Application Number 07-00002029 Permit . . . . PLUMBING Qty Unit Charge Per Extension 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA • PLB .WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1:00 9.0000 EA PLB. LAWN SPRINKLER SYSTEM 9.00 12.00 .7500 EA' PLB GAS PIPE >=5 9.00 1.00 15.0000 ---------------------------------------------------------------------------- EA PLB GAS METER 15.00" Permit GRADING PERMIT Additional desc . Permit -Fee . . . . 15.00 Plan Check Fee .00 Issue Date Valuation 0 Expiration Date 4/12/08 Qty Unit,Charge Per Extension BASE FEE 15.00 Special Notes and Comments SFD - LOT 262, 5180 SF. PERMIT DOES .NOT INCLUDE POOL, SPA, BLOCK WALLS OR .DRIVEWAY APPROACH. 2001 CBC,,CMC, CPC, 2004 CEC, 2005 ENERGY CODES Other Fees . . . . ART IN PUBLIC PLACES=RES 609.25 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW :FEE 119..83 - DIF FIRE.PROTECTION-RES' 140.00 GRADING PLAN CHECK FEE 15.00 DIF LIBRARIES - RES 355.00 DIF`PARK MAINT FAC -. RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 44:.37 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION'- RES 1930.00 - Fee summary Charged Paid Credited Due Permit Fee Total 2432.34. .00 .00 2432.34 Plan Check Total 1341.74 .00 .00 1341.74 Other Fee Total 5263.45 .00 .00 5263.45. Grand Total 9037.53 .00 .00 9037.53 LQPERAIIT Bin # , City of La Quints . Building & Safety Division P.O. Box 1504, 78-495 Calle Tampico ' - La Quinta, CA 92253 - (760) 777-7012 �• Building- Permit Application and Tracking. Sheet Permit #' ' CO_�02c0i Project Address: S3- �p. � O Owner's Name: S A: P. Number: D Address: ILb Rim, STi !Telephone: (00. 960.Iq Legal Description:-Zip:City, Contractor:` . '•� 's„ Address: " Project Description: City, ST, Zip: - Telephoner State Lic. # : r Arch., Engr., Designer: City Lic. #: Address: City, ST, Zip: Telephone: 4_1 State Lic. #: Name of Contact Person: !, Construction Type: Occupancy: Project type (circle one): New' Add'n Alter Repair : Demo Sq. Ft.:-. # Stories:. # Units: Telephone # of Contact Person:Estimated Value of Project: ` APPLICANT:' DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd . TRACKING . PERMIT FEES Plan Sets ° Plan Check submitted Item • Amount Structural Calcs. Reviewed, ready for corrections+' ., Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Cales. Plans picked up Construction - Flood plain plan Plans` resubmitted Mechanical Grading plan - 2°", Review; ready for corrections/issue Electrical ' i Subcontactor List Called Contact Person , Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''" Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.LP.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees M .. r • ' � ,• : � . ` �`• • . t , .� i tom. y � T T � .. Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 ty . This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK #: FNrnALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Stev K ssler, Date: 10/05/07 Owner's Name: Steve Kessler Phone No. (760) 880-2919 Project Address: 53-664 Via Strada, La Quinta, CA Project Description: 1 Single Family Dwelling APN: 772-640-046 Tract #: Lot #'s: Type of Development: Residential XXL Commercial Industrial Total Square Feet of Building Area: 5,180 sq. Ft. Certification of Applicant/Owners: The person signing certifies at a above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorize to si0i on behalf of the owner/developer. Dated: 10/05/07 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing 17620 65995 Approval Prior to 1/1/87 i Number of Sq.Ft. 5,180.00 sq. ft. Amount per Sq.Ft. $ 3.48 Amount Collected $ 18,026.40 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Support Services Certificate issued by: Leticia C. Torres, Facilities Analyst Not Subject to Fee Requirement Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. LT:c/mydocs/devfees/certificate of compliance form tablesTO USE.doc 1/16/03 T Permit # 6tLi hlBQ P 9 ap'ag ty of La Quinta Building tai Safety Division.. P.O. Box 1504, 78-495 Calle Tampico l.a Quirita, CA-92253 - (760) 777-7012 Building Permit Application. and Tracking Sheet [PftrojeAddr(ss:' !j- Owner's Name: r: °�` )� Lrd —� Address: Legal Description: Contractor: -- City, ST, Zip: Telephone:7, t bb Address: — Project Description: City,-ST-,Zip:-- Telephone: State Lic. # • Arch., Engr., Designer: Address:City, City Lic. #:. ST, Zip:Telephone: ADemo rjConstruction State Lic. #: Type: Occupancy: Project type (circle one): New Add'n Alter Repair ' Name of Contact Person: Ft : i_. ...... ... ......._.. .... ..._ - Sq.... [;#Stories:.. ..... .. .#-Units:.....: . Telephone # of Contact?erson: '7LO — �LEstimated Value.of Project: APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Reed TRACKING . PERMIT FEES Plan Sets z Plan Check submitted (o� Item Amount Structure[ Calcs. Reviewed; ready for orrections �� Plan Check Deposit Truss Cales. �� Called Contact Person S Plan Check Balance Energy Calcs Plans picked up /� Construction Flood plain plan ,. Plans resubmitted Mechanical Grading. plan' .2" Review, ready for eorrectio s/ ue Electrical Subcontactor.List ' Called Contact Person Plumbing Grant Deed Plan §. picked up S.M I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''� Review, ready for correctionslissue Developer Impact Fee Planning Approval Called Contact Person A.LP.P. Pub. Wks. Appr Date of permit issue School Fees Total Fermit Fees SSS (raJ� Rk .r • y ' CITY OF LA YQUINTA' SUB-CONT,iRACTO _ LIST JOB ADDRESS93wo V S pA PERMIT NUMBER OWNER � -BUILDER S �Y-- ��• This form shall be posted on the job with the Building Infection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work on this job., Any changes to this list must be approved'by the Building Division prior to commencementof work. Failure, to comply will result in a stoppage of work and/or the voidance. AV i 1. N rTITLE.24 REPORT Title 24 Report for: Steve Kessler 53-664 Via Strada a La Quinta, -CA 92253 _ Project Designer: Stephen Nieto 78-120 Calle, Estado Suite 206 - La Quinta, CA 92253 .760-564-4707 Report Prepared By: Stephen Nieto South West Concepts_ 78-115 Calle Estado, Suite 201 'La Quinta, CA 92253 0 (76 ,564-4707 5 . t) QUANTA CITY OF SA DEPT• - . BUILDING & SA a APPROVED FOR CONST UCTION Job Number: oATe- i Date: 5/6/2008 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is .authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: 262 User Number: 5970 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R Steve Kessler 5,166 ft2 Existing Floor Area: 516/2008 Project Title Raised Floor Area: 0 ft2 Date �3-6.64�Lia-Strada-Ig Q «ta Average Ceiling Height: 11.0 ft Project Address 1.00 Building Permit # Seth W -SL-oncep_ts (760) 564-4707 Documentation Author Telephone Plan Check/Date _Fn.ergyPro Complia ce Method CA Climate Zone 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 0.91 1.68 -0.77 Space Cooling 46.11 38.33 7.78 Fans 6.54 5.53 1.02 Domestic Hot Water 4.97 5.95 -0.98 Pumps 0.00 0.00 0.00 Totals 58.53 51.49 7.04 than Standard: Building Type: [k Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (W) 270 deg Natural Gas Area: 793 ft2 Avg. U: 0.38 0% Total Conditioned Floor Area: 5,166 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 5,165 ft2 Average Ceiling Height: 11.0 ft Number of Dwelling Units: 1.00 Ratio: 15.4% Avg. SHGC: 0.35 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC UNIT 1 9 407407 25 274 _04.7 Sleeping- _Sleeping.Stat- 2 -n/a JiVJ� UNITS 2&3 2 75+9 3172 0_53 Living LivingStat- _2 _nLa OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall Wnnd 72 _0-069 -R21 R-0 0_-135- 9.0 Wall_ WcLod_ _294 0..069 _R21 X0_0_-270 go Wall_ Wood 80.8 0.06.9 R-21 _R-0_0- 0 gn Wall Wnod 202 X069 -B21 -B_0 0 _9.0 9.0 Wall_ Wood 6620.069 R_21 R`0.0 180 _ 90 Wall Wand_ 542 _0._0.69 _R21 -B-0-0_ 270 90 IIO.oL None_ 48_ _0-.50.0_ _Non>, _B=0-0_ 270_ 90 Wall Wnod 378 -O-G6.9- -R21 0_ 0_ 90 Wall Wood 402 -U69_R21R-0.0_ 90_ 90 Wall Wood_ 858 _0...069 R_21 X0.0_ 180 _90 Gains Condition Y / N Status JA IV Reference Location / Comments IX ❑New D9 -A6 SI FFPING_ZONE EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: 262 Paoe:3 of 14 1 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Steve Kessler 5/6/2008 Project Title Date - FENESTRATION SURFACES # Type Area U -Factor' - SHGCZ True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments 1- Window Rear (SE) 48.0 0.340_NFRG JIM AERO X135 _90- New Andersen Permashield _SL FFFING ZONE 2 Window Front (W) 25.0 0.340 NFRC 0_33 NFRC - 270 90 New Andersen Permashield SLEEPING ZONE 3 Window Front (W) 15.0 0.340 NFRC 0_33 NFRC 270 90 New Andersen Permashield SLEEPING ZONE 4 Window Front (W) 6.0 0.340 NFRC 0_33 NFRC 270 90 New Andersen Permashield SLEEPING ZONE 5 Window Left (N) 12.4 0.990 116-A 0_74 116-B 0 90 New Single Non Metal Clear SLEEPING ZONE 6 Window Left (N) 4.0 0.340 NFRC 0.33 NFRC 0 90 New Andersen Permashield SLEEPING ZONE L Window Left (N) 22.0 0.340 NFRC 0.33 NFRC 0 90 New Andersen Permashield SLEEPING ZONE 8 Window Left (N) 21.3 1.280 116-A 0.80 116-B 0 90 New Single Metal Clear SLEEPING ZONE 9 Window Left (N1 4.0 0.340 NFRC 0.33 NFRC 0 90New Andersen Permashield SLEEPING ZONE 10 Window Left (N) 4.0 0_340 NFRC 0_33 NFRC 0 90 New Andersen Permashield SLEEPING ZONE 11 Window Left (N) 4.0 0.340 NFRC 0_33 NFRC 0 90 New Andersen Permashield SLEEPING ZONE 12 Window Rear (E) 20.0 0.340 NFRC 0_33 NFRC 90 90 New Andersen Permashield SLEEPING ZONE 1a Window Rear (E) 48.0 3� NFRC 0.33 NFRC _90 -9Q New. Andersen Permashield SLEEPING_ZONE 14 Window Right (S) 48.0 0.340 NFRC 0_33 NFRC 180 90 New Andersen Permashield SLEEPING ZONE ' 15 Window front (W) 30.0 0.340 NFRC 0_33 NFRC 270 90 New Andersen Permashield LIVING ZONE 16 Window Front (W) 30.0 0.340 NFRC 0_33 NFRC 270 90 New Andersen Permashield LIVING ZONE 17 Window Front (W) 30.0 0.340 NFRC 0_33 NFRC: 270 90 New Andersen Permashield LIVING ZONE 18 Window Left (N) 6.0 0.340 NFRC 0_33 NFRC 0 90 New Andersen Permashield LIVING ZONE 19 Window Left U 48.0 0.340 NFRC 0.33 NFRC 0 90 New Andersen Permashield LIVING ZONE 1. Indicate source either from NFRC or Table 116A. - 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Insulation < Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 269 None No Insulation 26-A1 Window SLEEPING ZONE Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. VVd. Len. Hgt. LExt . REA Dist Len Hgt Dist Len Hgt 1 Bug Screen 0.76 8.0 6.0 1.0 1.0 2.0 2.0 2 Bug Screen 0.76 5.0 5.0 1.0 1.0 2.0 2.0 3 Bug Screen 0.76 5.0 3.0 1.0 1.0 2.0 2.0 4 Bug Screen 0.76 2.0 3.0 1.0 1.0 2.0 2.0 5 Bug Screen 0.76 4.6 2.6 1.0 1.0 2.0 2.0 6 Bug Screen 0.76 2.0 2:0 1.0 1.0 2-0 2.0 7 Bug Screen 0.76 5.5 - 4.0 1.0 1.0 2.0 2.0 8 Bug Screen 0.76 5.3 4.0 1.0 1.0 2.0 2.0 9 Bug Screen 0.76 2.0 2.0 1.0 1.0 2.0 2.0 10 Bug Screen 0.76 2.0 2.0 •1.0 1.0 2.0 ` 2.0 11 Bug Screen 0.76 2.0 2.0 1.0 1.0 2.0 2.0. 12 Bug Screen 0.76 5.0 4.0 1.0 1.0 2.0 2.0 13 Bug Screen 0.76 8.0 6.0 1.0 1.0 2.0 2.0 14 Bug Screen 0.76 8.0 6.0 . 1.0 1.0 2.0 2.0 15 Bug Screen 0.76 6.0 50 -71.0 1.0 2.0 2.0 16 Bug Screen 0.76 6.0 . 5.0 r 1.0 1.0 2.0 2.0 17 Bug Screen 0.76 6.0 5.0 1.0 1.0 2.0 2.0 18 Bug Screen 0.76 " 2.0 3.0 1.0 1.0 2.0 2.0 19 Bug Screen 0.76 8.0 6.0 1.0 .1.0 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type 'of) fin.) Cap. Cond. R -Val. ' JA IV Reference Status Comments PERIMETER LOSSES Insulation < Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 269 None No Insulation 26-A1 New SLEEPING ZONE Slab Perimeter 305 None No Insulation 26-A1 New LIVING ZONE Run Initiation Time: 05/06/08 09:06:02 Run Code: 1210089962 EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: 262 Page:4 of 14 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Steve Kessler 5/6/2008 Project Title Date FENESTRATION SURFACES # Type Area U -Factor' ' SHGCZ True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments 2Q Window Overhang 480 -0.34.0_NERr__QM _NFRC () _9.0_ New Andersen Permashield LIVING 70NF 21 Window Rear (E) 200.0 0.340 NFRC 0_33 NFRC 90 90 New Andersen Permashield LIVING ZONE 22 Window Rear (E) 19.5 0.340 NFRC 0_33 NFRC 90 90 New Andersen Permashield LIVING ZONE 23 Window Rear (E) 39.0 0.340 NFRC 0_33 NFRC 90 90 New Andersen Permashield LIVING ZONE 24 Window Rear (E) 19.5 0.340 NFRC 0_33 NFRC 90 90 New Andersen Permashield LIVING ZONE 25 Window Right (S) 24.0 0.340 NFRC 0_33 NFRC 180 90 New Andersen Permashield LIVING ZONE 26 Window Right (S,) 17.5 0.340 NFRC 0.33 _NFRC 180 90 New Andersen Permashield LIVING ZONE 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 8.0 6.0 1.0 1.0 2.0 2.0 21 Bug Screen 0.76 10.0 20.0 1.0 1.0 2.0 2.0 22 Bug Screen 0.76 6.5 3.0 1.0 1.0 2.0 2.0 23 Bug Screen 0.76 6.5 6.0 1.0 1.0 2.0 2.0 24 Bug Screen 0.76 6.5 3.0 1.0 1.0 2.0 2.0 25 Bug Screen 0.76 8.0 3.0 1.0 1.0 2.0 2.0 26 Bug Screen 0.76 5.0 3.5 1.0 1.0 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 05106/08 09.06.02 Run Code: 1210089962 L. EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: 262 Page:5 of 14 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R Steve Kessler 5/6/2008 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC UNIT 1 Central Furnace 93% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC UNITS 2&3 Central Furnace 93% AFUE Split Air Conditioner 14.0 SEER New Setback Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) HVAC DISTRIBUTION Loss (%) Ext. A O Smith Water Products CTG -50- Small Gas No Pipe Insulation _227— 2 37,000 50 New 0.62 n/a n/a Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC UNIT 1 Ducted Ducted Attic 4.2 New Yes HVAC UNITS 2&3 Ducted Ducted Attic 4.2 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. A O Smith Water Products CTG -50- Small Gas No Pipe Insulation _227— 2 37,000 50 New 0.62 n/a n/a Multi-Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Stephen Nieto Address: 78-120 Calle Estado Suite 206 La Quinta. CA 92253 Telephon 760-564-4707 Lic. #: d d"I J (sign e) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Stephen Nieto Title/Firm: South West Concepts Address: 78-115 Calle Estado, Suite 201 La Quinta, CA 92253 Teleph 760 564-4707 (si ture) (date) Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Steve Kessler 5/6/2008 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies uaseu vn me auequacy or ine speciai jusuncation ana aocumentation suomittea. Plan I Field The HVAC System "HVAC UNIT 1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC UNITS 2&Y must meet all CEC Criteria for a Zonally Controlled system servinq only Livinq Areas. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a �..., r,. ,....`. w,...y apvlw.�..— ung a..u,u. vers canon nieuwua. Plan Field The HVAC System "HVAC UNIT 1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC UNITS MY incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: 262 Page:7 of 14 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (•) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: ❑ ❑ ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ ❑ ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑ El Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. ❑ ❑ ❑ ,1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑ ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑ ❑ ISpace Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: 262 Page:8 of 14 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (`) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT ISpace Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: ❑ ❑ n ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ■❑ a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ 0 ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGHEFFICACY OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, LU ll 1:1 El El luminaire has ins a ed HIDla § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ Fx] ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑ ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: 262 Page:9 of 14 Residential Kitchen Lighting Worksheet WS -5R Steve Kessler 5/6/2008 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens., . High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1) 28w Compact Fluorescent 2D Elec Yes X ' No 28.0 x 5 = 140 or 1 57w Compact Fluorescent Tri /Quad Tpin Yes X No 62.0 X'. 4 - 248 or WeCRecessed Incandescent Yes No X 60.0 x 3 or 180 Yes No x_ or Yes No x = or Yes No x = or Yes No x or Yes No x = or Yes No x - or Yes No z _ or Yes No x _ or Yes No x = or Yes No - x = " or Yes No x - or Yes No x - or ` Yes No x - or Yes No x = or Yes No x = or Yes No X = or Yes' No x = or Total A: 388 B: 180 COMPLIES IF A z B YES ® NO El. x 4 F-EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: 262 Page: 10 of 14 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Steve Kessler 5/6/2008 SYSTEM NAME FLOOR AREA HVAC UNIT 1 2,407 Number of Systems 1 Heating System Output per System 56,000 Total Output (Btuh) 56,000 Output(Btuh/sgft) 23.3 Cooling System Output per System 47,500 Total Output (Btuh) 47,500 Total Output (Tons) 4.0 Total Output (Btuh/sgft) 19.7 Total Output (sgft/Ton) 608.1 Air System CFM per System 1,545 Airflow (cfm) 1,545 Airflow (cfm/sgft) 0.64 Airflow (cfm/Ton) 390.3 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions EATING SYSTEM PSYCHROME 26.0 of 68.5 of Outside Air 0 cfm Supply Fan 1545 cfm 68.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensiblel Latent CFM I Sensible 1,084 20,092 2,458 820 27,075 0 2,414 2,499 0 0 0 0 0 0 0 0 0 2,414 2,499 24 920 2 458 F7 32,073 Bryant 556AN048-B/350MAV048060 33,459 9,324 56,000 Total Adjusted System Output 33,459 9,324 56,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Cream Temperatures at Time of Heatina Peak) 68.5 of 0 102.5 of Heating Coil h Return Air Ducts 'I Supply Air Ducts 101.0 of ROOMS 70.0 of COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 of 79.5 / 65.5 of 79.5 / 65.5 of 59.1 / 58.0 of O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 60.6 / 58.5 of 1545 cfm 50.2% R.H. ROOMS 79.5/65.5 of 78.0 / 65.0 of h Return Air Ducts �1 EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: 262 Page: 11 of 14 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Steve Kessler 5/6/2008 SYSTEM NAME FLOOR AREA HVAC UNITS 2&3 2,759 Number of Systems 2 Heating System Output per System 56,000 Total Output (Btuh) 112,000 Output (Btuh/sqft) 40.6 Cooling System Output per System 36,000 Total Output (Btuh) 72,000 Total Output (Tons) 6.0 Total Output (Btuh/sgft) 26.1 Total Output (sgft/Ton) 459.8 Air System CFM per System 1,200 Airflow (cfm) 2,400 Airflow (cfm/sgft) 0.87 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above gi HEATING SYSTEM 26.0 OF Outside Air 0 cfm 68.8 OF at ARI conditions 68.8 OF Supply Fan 2400 cfm Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,687 30,032 2,70 F 746 32,915 0 3,608 3,038 0 0 0 0 0 0 0 0 0 3,6081 3,038 37,2 2 70 38 992 Bryant 556AN036-E/350MAV036060 49,945 15,188 112,000 Total Adjusted System Output49,945 15,188 112,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm I W12 am RICS (Airstream Temperatures at Time of Heating Peak) 68.8 OF ® 112.70F Heating Coil N Return Air Ducts 4 Supply Air Ducts 111.5°F ROOMS 70.0 OF DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6°F 79.4/65.7°F 79.4/65.8°F 59.9/58.7°F O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 61.3 / 59.3 OF 2400 cfm 51.1% R.H. ROOMS 79.4/65.7 F ° 78.0 / 65.3 OF h Return Air Ducts � EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: 262 Page: 12 of 14 1 ROOM LOAD SUMMARY PROJECT NAME Steve Kessler DATE 5/6/2008 SYSTEM NAME HVAC UNIT 1 FLOOR AREA 2,407 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE SLEEPING ZONE SLEEPING ROOMS 1 1,084 20,092 2,458 1,084 20,092 2,458 820 27,075 I ' 1 PAGE TOTAL 1 1,084 20,092 2,458 820 27,075 TOTAL 1,084 20,092 2,458 820 27,075 EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: 262Page: 13 of 14 ROOM LOAD SUMMARY PROJECT NAME Steve Kessler DATE 5/6/2008 SYSTEM NAME HVAC UNITS 2&3 FLOOR AREA 2,759 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE LIVING ZONE LIVING AREA 1 1,687 30,032 2,701 1,687 30,032 2,701 746 32,915 PAGE TOTAL 1 1,687 30,032 2,701 746 32,915 TOTAL 1 1,687 30,032 2,701 746 32,915 EnergyPro 4.4 by EnergySoft User Number: 5970 Job Number: 262 Page: 14 oFT7771 TITLE 24 REPORT Title 24 Report for: Steve Kessler 53-664 Via Strada La Quinta, CA 92253 DATE !2 /6-2 BY Project Designer: Stephen Nieto 78-120 Calle Estado Suite 206 La Quinta, CA 92253 760-564-4707 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONST CTION Report Prepared By: Stephen Nieto South West,Concepts 78120 Calle Estado, Suite 206 La Quinta, CA 92253 (760) 564-4707. Job Number: a 262 Date: 2/5/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: 262 User Number - 5970 j TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 8 Form WS -5R Residential Kitchen Lighting 10 HVAC System Heating and Cooling Loads Summary 11 Room Load Summary 13 EnergyPro 4.3 by EnergySoft Job Number: 262 User Number: 5970 Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R Steve Kessler 5,166 ft2 Existing Floor Area: 2L512Q07 Project Title Raised Floor Area: 0 ft2 Date _5.3-664 Via S.trad.a-I a_Qllinta ft2 Average Ceiling Height: 11.0 Project Address Number of Dwelling Units: 1.00 Call_ Wood- 6.62 Building Permit # Snuth WesLCDn.Cep_ts Wall_ Wood_ 542 _0_0-6.9 -&21 _R -0.O_ (760) 564-4707 Doo>- None 48_ Documentation Author _27.090 Wall Wood 3Z8_ Telephone plan Check/Date _EnergyPrn Compliance Method 94_ 90. Wall_ Wood 8.58 15 Climate Zone -180_ 90 Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 0.91 0.52 0.38 Space Cooling 46.11 43.76 2.35 Fans 6.54 6.28 0.26 Domestic Hot Water 4.97 5.95 -0.98 Pumps 0.00 0.00 0.00 Totals 58.53 56.52 2.01 Percent better Building Type: [jd Single Family [:)Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (W) 270 deg Natural Gas Area: 793 ft 2 Avg. U: 0.38 Ratio: 15.4% Avg. SHGC: 0.35 Total Conditioned Floor Area: 5,166 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 5,165 ft2 Average Ceiling Height: 11.0 ft Number of Dwelling Units: 1.00 Call_ Wood- 6.62 Number of Stories: 1 Wall_ Wood_ 542 BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units HVAC UNIT 1 2407 25 274 047 HV2 756 _3J-728 X53_ OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Will Wood 72 _0.0.&90_91_B-00_-13590 Wall_ Wood_ _294 _0_069_ R-21 R-0 0 270 90 /.all_ Wood 8Q8_ _0..0.6.9 _R-21 R-0 0 2_9.0 Wall Wood _202 0_0.69 R-21 R-0 0 90__90 Call_ Wood- 6.62 O_0,6.9_ R_21 R-0.0 180 9Q Wall_ Wood_ 542 _0_0-6.9 -&21 _R -0.O_ X7.0_ 9Q Doo>- None 48_ _0_5.0.0_ -None_ _B -Q 0_ _27.090 Wall Wood 3Z8_ -0_06.9 R-21 _B-0 0 0_90 Wall_ Wood X02 0..069 R-21 _R-0 0 94_ 90. Wall_ Wood 8.58 0_0.69 _R21 R-0 0 -180_ 90 Zone Type Sleeping Living Gains Condition Y / N Status JA IV Reference Thermostat Vent Type Hgt. Area -SleepingStaL 2 -n1a - Iivin fat_ _2 _n1a Location / Comments New 0.9_A6 3LEEPJNG_Z0NF New 09-A6 S.LEEPJN.G_ZONE New 09-A6 SLEEPING ZONE New 09-A6 SLEEPJNGZONF New 09-A6 SLEEEI&GZONE New -O9 -A6 New 28-A4 LUJUG7-O.NE LLVINGZONE New 09-A6 LLV_LN.G7QNF New 09-A6 LLVIN.GZONE New 09-A6 C, 70 EnergyPro 4.3 by EnergySoft User Number: 5970 Job Number: 262 Paae:3 of 14 1 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Steve Kessler 2/5/2007 Project Title Date FENESTRATION SURFACES # Type Area U -Factor' SHGC2 True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments 1 Mftdow-Rear (SES 48 0 -340 _NERC -QM -NER0 x.3.5 90 New Andersen Permashield SLEEPING ZONE 2 Window Front (W) 25.0 0.340 NFRC 0_33 NFRC 270 90 New Andersen Permashield SLEEPING ZONE 3 Window Front (W) 15.0 0.340 NFRC 0_33 NFRC 270 90 New Andersen Permashield SLEEPING ZONE 4 Window Front (W) 6.0 0.340 NFRC 0_33 NFRC 270 90 New Andersen Permashield SLEEPING ZONE 5 Window Left (N) 12.4 0.990 116-A 0_74 116-B 0 90 New Single Non Metal Clear SLEEPING ZONE 6 Window Left (N) 4.0 0.340 NFRC 0_33 NFRC 0 90 New Andersen Permashield SLEEPING ZONE 7 Window Left (N) 22.0 0.340 NFRC 0_33 NFRC 0 90 New Andersen Permashield SLEEPING ZONE 8 Window Left (N) 21.3 1.280 116-A 0.80 116-B 0 90 New Single Metal Clear SLEEPING ZONE 9 Window Left (N) 4.0 0.340 NERC0 33 NFRC 0 90 New Andersen Permashield SLEEPING ZONE 1Q Window Left (N) 4.0 0,34 NFRC 0_33 NFRC 0 90 New Andersen Permashield SLEEPING ZONE 11 Window Left (N) 4.0 0.340 NFRC 0_33 NFRC 0 90 New Andersen Permashield SLEEPING ZONE 12 Window Rear (E) 20.0 0.340 NFRC 0_33 NFRC 90 90 New Andersen Permashield SLEEPING ZONE 1a Window Rear (E) 48.0 0.340 NFRC 0.33 NFRC 90 --9k New Andersen Permashield SLEEPINGZONE 14 Window Right (S) 48.0 0.340 NFRC 0_33 NFRC 180 90 New Andersen Permashield SLEEPING ZONE 15 Window Front (W) 30.0 0.340 NFRC 0_33 NFRC 270 90 New Andersen Permashield LIVING ZONE 16 Window Front (W) 30.0 0.340 NFRC 0_33 NFRC 270 90 New Andersen Permashield LIVING ZONE 17 Window Front (W) 30.0 0.340 NFRC 0_33 NFRC 270 90 New Andersen Permashield LIVING ZONE 18 Window Left (N) 6.0 0.340 NFRC 0_33 NFRC 0 90 New Andersen Permashield LIVING ZONE 19 Window Left (N) 48.0 0.340 NFRC 0_33 NFRC 0 90 New Andersen Permashield LIVING ZONE 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. 1.0 INTERIOR AND EXTERIOR SHADING Area Thick. Heat Inside (sf) (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments PERIMETER LOSSES Insulation Condition Window Type Overhang R -Val. Location Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt 1 Bug Screbn 0.76 8.0 6.0 1.0 1.0 2.0 2.0 2 Bug Screen 0.76 5.0 5.0 1.0 1.0 2.0 2.0 3 Bug Screen 0.76 5.0 3.0 1.0 1.0 2.0 2.0 4 Bug Screen 0.76 2.0 3.0 1.0 1.0 2.0 2.0 5 Bug Screen 0.76 4.6 2.6 1.0 1.0 2.0 2.0 6 Bug Screen 0.76 2.0 2.0 1.0 1.0 2.0 2.0 7 Bug Screen 0.76 5.5 4.0 1.0 1.0 2.0 2.0 8 Bug Screen 0.76 5.3 4.0 1.0 1.0 2.0 2.0 9 Bug Screen 0.76 2.0 2.0 1.0 1.0 2.0 2.0 10 Bug Screen 0.76 2.0 2.0 1.0 1.0 2.0 2.0 11 Bug Screen 0.76 2.0 2.0 1.0 1.0 2.0 2.0 12 Bug Screen 0.76 5.0 4.0 1.0 1.0 2.0 2.0 13 Bug Screen 0.76 8.0 6.0 1.0 1.0 2.0 2.0 14 Bug Screen 0.76 8.0 6.0 1.0 1.0 2.0 2.0 15 Bug Screen 0.76 6.0 5.0 1.0 1.0 2.0 2.0 16 Bug Screen 0.76 6.0 5.0 1.0 1.0 2.0 2.0 17 Bug Screen 0.76 6.0 5.0 1.0 1.0 2.0 2.0 18 Bug Screen 0.76 2.0 3.0 1.0 1.0 2.0 2.0 19 Bug Screen 0.76 8.0. 6.0 1.0 1.0 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Type Area Thick. Heat Inside (sf) (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 269 None No Insulation 26-A1 New SLEEPING ZONE Slab Perimeter 305 None No Insulation 26-A1 New LIVING ZONE Run Initiation Time: 02/05/07 11.21.13 Run Code: 1170703273 EnergyPro 4.3 by EnergySoft User Number: 5970 Job Number: 262 Page•4 of 14 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Steve Kessler 2/5/2007 Project Title Date FENESTRATION SURFACES # Type Area U -Factor' SHGCZ True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments 20. -Window--Left--(N)- --A8-0- _0 340 NERC -U3 NERC 0_ -9.0_ New fln.denw Lee.rmashield 1LVING_ZO-NF 21 Window Rear (E) 200.0 0.340 NFRC 0_33 NFRC 90 90 New Andersen Permashield LIVING ZONE 22 Window Rear (E) 19.5 0.340 NFRC 0_33 NFRC 90 90 New Andersen Permashield LIVING ZONE 23 Window Rear (E) 39.0 0.340 NFRC 0_33 NFRC 90 90 New Andersen Permashield LIVING ZONE 24 Window Rear (E) 19.5 0.340 NFRC 0_33 NFRC 90 90 New Andersen Permashield LIVING ZONE 25 Window Right (S) 24.0 0.340 NFRC 0_33 NFRC 180 90 New Andersen Permashield LIVING ZONE 26 Window Right (S,) 17.5 0.340 NFRC 0.33 NFRC 180 90 New Andersen Permashield LIVING ZONE 0.76 6.5 3.0 1.0 1.0 2.0 2.0 25 Bug Screen 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. Hgt. Dist Len Hgt 20 Bug Screen 0.76 8.0 6.0 1.0 1.0 2.0 2.0 Ti Bug Screen 0.76 10.0 20.0 1.0 1.0 2.0 2.0 22 Bug Screen 0.76 6.5 3.0 1.0 1.0 2.0 2.0 23 Bug Screen 0.76 6.5 6.0 1.0 1.0 2.0 2.0 24 Bug Screen 0.76 6.5 3.0 1.0 1.0 2.0 2.0 25 Bug Screen 0.76 8.0 3.0 1.0 1.0 2.0 2.0 26 Bug Screen 0.76 5.0 3.5 1.0 1.0 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Type L Insulation R -Val. Location Condition Location/ JA IV Reference Status Comments Run Initiation Time: 02/05/07 11.21.13 Run Code: 1170703273 EnergyPro 4.3 by EnergySoft User Number: 5970 Job Number: 262 Page:5 of 14 Certificate Of Compliance: Residential _ (Part 3 of 4) CF -1 R Steve Kessler Duct Condition Ducts Location Heating Cooling Location R -Value Status 2/5/2007 HVAC UNIT 1 Ducted Ducted Attic Project Title Yes HVAC UNITS 2&3 Ducted Ducted Attic 4.2 New Date Cap. Condition Factor HVAC SYSTEMS System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext A O Smith Water Products CTG -50- Small Gas No Pipe Insulation -22 2 37,000 Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC UNIT 1 Central Furnace 93% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC UNITS 2&3 Central Furnace 93% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC UNIT 1 Ducted Ducted Attic 4.2 New Yes HVAC UNITS 2&3 Ducted Ducted Attic 4.2 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext A O Smith Water Products CTG -50- Small Gas No Pipe Insulation -22 2 37,000 50 New 0.62 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump . Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation 4 REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Stephen Nieto Address: 78-120 Calle Estado Suite 206 _ Miw# (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Stephen Nieto Title/Firm: South West Concepts Address: 78120 Calle Estado, Suite 206 La Quinta CA 92253 ,Telephone: 760 564-4707 _ Z-�—o (signature) (date) STAMP Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Steve Kessler 2/5/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the ruequacy or ine 5peciai fusuncauon ana aocumentaaon suomntea. Plan I Field The HVAC System "HVAC UNIT 1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC UNITS 2&Y must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- ••rr••,•"• �••• r�.. 4-1 ua—tj — aNNIvvcu aoauny dnuwr venncduan rneUMU15 ana mu5t oe reporEeo on ine L,?--4Kplan installation certificate. Field The HVAC System "HVAC UNIT 1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC UNITS 2&Y incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. EnergyPro 4.3 by EnergySoft User Number: 5970 Job Number: 262 Page:7 of 14 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑ ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑ ❑ § 150(d): Minimum R-13 raised Floor insulation in framed Floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 1. Masonry and factory -built fireplaces have: 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. b. outside air intake with damper and control, Flue damper and control ❑ ❑X ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ entirely in conditioned space. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include E] El 1:1CF-6R ❑ Form: Page:8 of 14 § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑ ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ ❑R ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑ ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ 0 ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 5970 Job Number: 262 Page:8 of 14 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. _. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ T ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined❑ x❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑ ❑ controlled by an occupant sensor that complies with Section 1) 9(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 5970 Job Number: 262 Page:9 of 14 • h Residential Kitchen Liqhtinq Worksheet WS-5R Steve Kessler 2/5/2007 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. t Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? -• Watts . Quantity Watts Other Watts 1 57w Com act Fluorescent Tri /Quad 4 in Yes X No 62.0 x 6 = 372 or Recessed Incandescent Yes No X 60.0 x 2 or 120 Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x _ or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 372 B: 120 COMPLIES IF Az B YES X❑ NO ❑ EnergyPro 4.3 by EnergySoft User Number: 5970 Job Number: 262 Page: 10 of 14 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Steve Kessler 2/5/2007 SYSTEM NAME FLOOR AREA HVAC UNIT 1 2,407 ENGINEERING CHECKS Number of Systems 1 Heating System Output per System 56,000 Total Output (Btuh) 56,000 Output (Btuh/sgft) 23.3 Cooling System Output per System 47,500 Total Output (Btuh) 47,500 Total Output (Tons) 4.0 Total Output (Btuh/sgft) 19.7 Total Output (sgft/Ton) 608.1 Air System CFM per System 1,545 Airflow (cfm) 1,545 Airflow (cfm/sgft) 0.64 Airflow (cfm/Ton) 390.3 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 ote: values above given at ARI conditions :ATING SYSTEM PSYCHROMETRICS 26.0 of 68.4 of 68.4 of Outside Air 0 cfm Supply Fan 1545 cfm 68.4 of COOLING 111.0 / 77.6 of Outside Air 0 cfm 79.6/65.8 of LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent I CFM I Sensible 1,204 21,728 3,026 870 28,579 0 2,611 2,638 0 0 0 0 0 0 0 0 0 2,6111 2,638 26,949 3,026 33,855 Bryant 556AN048-B/350MAV048060 33,108 9,918 56,000 Total Adjusted System Output33,108 9,918 56,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 'earn Temaeratures at Time of Heatina Peak) 102.5 of Heating Coil K Return Air Ducts `{ of Cooli 79.6 165.8 of 79.6 / 65.9 of 59.5 / 58.3 of Supply Fan Cooling Coil 1545 cfm h Return Air Ducts 4 Supply Air Ducts 100.8 of ROOMS 70.0 of I Supply Air Ducts 61.0 / 58.9 OF 51.2% R.H. ROOMS 78.0 / 65.3 of I EnergyPro 4.3 by EnergySoft User Number: 5970 Job Number: 262 Page:11 of 14 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Steve Kessler 2/5/2007 SYSTEM NAME FLOOR AREA HVAC UNITS 2&3 2,759 Number of Systems 2 Heating System Output per System 56,000 Total Output (Btuh) 112,000 Output (Btuh/sgft) 40.6 Cooling System Output per System 36,000 Total Output (Btuh) 72,000 Total Output (Tons) 6.0 Total Output (Btuhlsgft) 26.1 Total Output (sgft/Ton) 459.8 Air System CFM per System 1,200 Airflow (cfm) 2,400 Airflow (cfmisgft) 0.87 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I ensible 1,828 31,907 3,35 787 34,639 0 3,834 3,197 0 0 0 0 01 0 0 0 0 3,8341 3,197 39,575 3,35 41,034 Bryant 556AN036-E/350MAV036060 49,561 15,844 112,000 Total Adjusted System Output 49,561 15,844 112,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Note: values above given at ARI conditions I L- JEATING SYSTEM PSYCHROMETRICS (Airstream Tei 26.0 of 68.7 of 68.7 of n 112,60F Outside Air 0 cfm Supply Fan 2400 cfm 68.7 of 111.0/77.6OF 79.5/66.0 Outside Air 0 cfm 79.5/66.0 of Heating Coil Tem Heatina Pea h Return Air Ducts '4 79.5/ 66.0 of 0 60.1 / 59.0 of 0 Supply Fan 2400 cfm Cooling Coil h Return Air Ducts 4 Supply Air Ducts 111.3 of ROOMS 70.0 of Supply Air Ducts 61.6 / 59.5 of 51.9% R.H. ROOMS 78.0 / 65.5 of EnergyPro 4.3 by EnergySoft User Number: 5970 Job Number: 262 Page: 12 of 14 ROOM LOAD SUMMARY PROJECT NAME Steve Kessler DATE 2/5/2007 SYSTEM NAME HVAC UNIT 1 FLOOR AREA 2,407 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE SLEEPING ZONE SLEEPING ROOMS 1 1,204 21,728 3,026 1,204 21,728 3,026 870 28,579 PAGE TOTAL 1,204 21,728 3,026 870 28,579 TOTAL 1 1,204 21,728 3,02]6[::;1:: 28,579 EnergyPro By EnergySoft User Number: User Job Number: 262 Page: 13 of 14 ROOM LOAD SUMMARY PROJECT NAME Steve Kessler DATE 2/5/2007 SYSTEM NAME HVAC UNITS 2&3 FLOOR AREA 2,759 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE LIVING ZONE LIVING AREA 1 1,828 31,907 3,351 1,828 31,907 3,351 787 34,639 PAGE TOTAL 1 1,828 31,907 3,351 TOTAL 1,828 31,907 3,351 787 34,639 787 34,639 EnergyPro By EnergySoft User Number: User Job Number: 262 Page:14 of 14