Loading...
12-1481 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO . LA QUINTA, CALIFORNIA 92253 4 VOICE (760) 777-7012 FAX (760) 777-7011 BUILDING & SAFETY DEPARTMENT, INSPECTIONS (760) 777-7153 BUILDING PERMIT .Application Number, 12-00001.481 Property Address: 53615 VIA STRADA APN: 777-200-006- - - Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: LOW 'DENSITY RESIDENTIAL Application valuation: 488004 D /n\ 11 Date: Owner: Lr�1 U SEDONA HOM 40101 MONT E A APR 082013 STE. B-1-2 RANCHO MI GE CITY OF LA QUINTA 4/08/13 LQPERMIT �t L f t , Contractor: Applicant: Architect or EEngineer: SUNROSE CORPORATION: 4 40101 MONTEREY AVE STE B1-214, RANCHO; MIRAGE, CA 92270 . //I (760)773-6633 Lia. No.: 533670 " LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION ' I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: - - - Section 7000) of Division 3 of the Business and Profess' aIsCode, and my License is in full force and effect. - 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: B License No-: 533670 _ for by Section 3700 of the Labor Code, for the performance of the work for which this permit is - - �,/ _ll Date: °?J U 13 Contractor: issued. - - _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work forwhich this permit is issued. My workers' compensation. - " OWNER- BUILDER DECLARATION - - - insurance carrier and policy number are: hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier STATE FUND Policy Number 1948056-2013 ' following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to " - _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any - " construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires theapplicantfor the - . person in any manner so as to become sject t0 the workers' compensation laws of California, -. .. - permit to file.a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State -- - and agree that, if ) should become su c to the workers' compensation provisions of Section" License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or - 3700 of the Labor Code, I shall fo9KO comply with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption: Any violation of Section 7031.5 by�j,G - ^ any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)•: - Date: [- . �D tel. y� Applicant: - - '• I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and - " ' the structure is novintended or, offered for sale (Sec. 7044, Business and Professions Code: The - WARNING: FAILURE TO SECURE WORKERS'".COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL - Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the - DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however; the building or improvement is sold within '. SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. - - one year of completion, the owner -builder will have the burden of proving that he or she did not build or _ improve for the purpose of sale.). - APPLICANT ACKNOWLEDGEMENT (_ 1 1, as owner of the property, am exclusively contracting with licensedcontractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractors) licensed - 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.)• whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_ 1 I am exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City " - of La Quinta, its officers, agents and employees for any act or omission related to the work being - - performed under or following issuance of this permit. Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced - - 'Within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject " CONSTRUCTION LENDING AGENCY permit to cancellation. - I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the above infor tion is correct. I agree to comply with all _ work for which this permit is issued (Sec. 3097, Civ. C.). city and county ordinances and'state laws relating to building constr n, and hereby authorize representatives - of this county to enter upon•the above-mentioned property for ins c n purposes. Lender's Name: � � " • Date>_"4=� Signature (Applicant or Agent): ' Lender's Address: . LQPERMIT �t L f ` Application Number . . . . . 12-0000148i Structure Information Construction Type . . . . . TYPE V, UNPROTECTED Occupancy Type . . DWELLG/LODGING/CONG <=10 Other struct info CODE_EDITION 2010 # BEDROOMS 4:00 FIRE SPRINKLERS YES GARAGE SQ FTG 714.00 PATIO SQ FTG 1705.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 4860.00 ---------------------------------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE 596.00 Permit . . . BUILDING PERMIT Additional desc '. Permit Fee- 2001.00 Plan Check Fee 1300.65 Issue Date Valuation 488004 Expiration Date-. 10/05/13 Qty Unit Charge Per Extension BASE FEE 639.50 389.00 3.5000 THOU BLDG 100,001-500,000 1361:50: Permit -ELEC-NEW RESIDENTIAL Additional desc.. _ Permit Fee 269`.34 Plan Check Fee 67.34 -Issue Date Valuation 0 Expiration Date 10/05/13 Qty Unit Charge ,Per Extension BASE FEE 15.00. 5456.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 190.96 2419•.00 '.0200 ELEC GARAGE OR NON-RESIDENTIAL 48.38 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit . . .' GRADING PERMIT Additional desc " Permit Fee 22.50 Plan Check Fee .00 Issue Date Valuation . . . 0 Expiration Date 10/05/13 l`1 Qty Unit Charge Per Extension BASE FEE 22.50 Permit . . . MECHANICAL LQPERMIT Application Number . . . . . 12-00001481 Permit . . . .MECHANICAL • Additional desc . Permit Fee . . . . 163.00 Plan Check Fee 40.75 Issue Date Valuation 0 - Expiration Date 10/05/13 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 9.0000 EA MECH FURNACE <=100K 27.00 3.00 16.5000 EA MECH B/C >3-15HP/>100K-800KBTU 49.50 10.00 6.5000 EA MECH VENT FAN 65.00 1.00. 6.5000 EA MECH EXHAUST HOOD - 6.50 Permit . . . PLUMBING Additional desc . Permit Fee 246.00 Plan Check Fee '. 61.50 Issue Date Valuation . . . . 0 Expiration Date 10/05/13 Qty Unit Charge Per, .Extension BASE FEE 15.00" 27.00 6.0000 EA PLB FIXTURE 162.00 15.0000 EA PLB BUILDING SEWER 15.00, 2.00 6:0000 EA PLB ROOF DRAIN, 12.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER,INST/ALT/REP 3:00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 10.00 .7500 EA PLB GAS PIPE >=5 7.50 1.00 15.0000 EA PLB GAS METER 15.00 --------------------------------------------------------------------------- Special Notes and Comments 5456 sf 2 STORY SFD. TYPE V -B ,CONSTR.W/' FIRE SPRINKLERS.2010 CODES. 2008 DIF. **PERMIT DOES NOT INCLUDE BLOCK WALLS, FENCES, SWIMMING POOLS, SPA, FIRE PIT, BBQ'S'and DRIVEWAY APPROACH** ARCHITECT for SOUTH COAST ARCHITECTS, INC. FRANK STOLZ C24409. ---------------------------------------------------------------------------- Other Fees ART IN PUBLIC PLACES -RES 720.01 BLDG STDS ADMIN "(SB1473). 20.00 DIF COMMUNITY CENTERS -RES 104.00 DIF CIVIC CENTER - RES 1089.00 ENERGY REVIEW FEE 130.07 DIF FIRE PROTECTION -RES 612.00 - DIF LIBRARIES - RES 334.,00 MULTI -SPECIES (MSHCP) FEE 1254.00 LQPERMIT ' Application Number . . . . .. 12-00001481 ---------------------------------------------------------------------------- f Other Fees . . . . . . . . . DIF PARK MAINT FAC - RES 51.00 DIF PARKS/REC - RES 1773.' 00 STRONG MOTION (SMI) - RES 48.80 DIF STREET MAINT FAC -RES 158.00 DIF TRANSPORTATION - RES 3592.00 Fee summary Charged Paid- Credited Due Permit Fee Total 2701.84 .00 .00 2701.84 Plan Check Total 1470.24 1000.00 .00 470.24 Other Fee Total 9885.88 .00 .00 9885.88 Grand Total 14057:96 1000.00 00 _ 13,057.96 LQPERMIT Building Address Owner C&tT 014 a" P.O. BOX 1504 78-495 CALLE TAMPICO Ix LA QUINTA, CALIFORNIA 92253 Mailing Address / the the tlCa � A.i_ rol City Zip Tel. ?7-Z-70 760-275= o State Lic. City & Classif. 6-S-336/70 Lic. # al C;•re Arch., Engr., Designer G, '��• Address j Tel. 1 r. l D Cit y h,�p�� Zip A U State /, n (� Lic. # 7 LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.' If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address ' This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT APPLICATION ONLY BUILDING: TYPE CONST. V OCC. GRP. A.P. Number !goo - -2-on —ooh Legal Description�7� Ivb -�'� "/4 Project Description Z Sq. Ft. Q n Q No. No. Dw. j Size i /QO Stories Units 1 NewV ' Add ❑ Alter ❑ Repair ❑ Demolition ❑ A.cA - `7 60 - Z7S- 90 1 IA h c 'TAAp Estimated Valuation r PERMIT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS o LI- - AMOUNT 100 n ri �l NI1111 npr P, ; v 11til 1_1 TY OF LA014NTA 1 FINANCE OE PT. ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE 0 4 BOx. 1504 LA QUINTA, CALIFORNIA 92247-1504 BUILDING & SAFETY DEPARTMENT GF 9�S 78-495 CALLS TAMPICO760 777-7012 `Il OF T1� ) 'LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 April 29, 2009 Mr. Paul Dewey Sunlite Development, Incorporated PO Box 10668 Palm Desert, CA 92255 RE: Second Building Permit. Extension Request — 53615 Via Strada. Dear Mr. Dewey: I have reviewed your letter dated April 27, 2009, requesting a second time extension for the construction of the single family residence at the above address under Building Permit #07-3031. -My letter of November. 12, 2008 granted your request for an extension through Monday April 27, 2009. As noted in that letter, the 2001 California Building Code does not allow more than one extension. Therefore, I am unable to grant your request. Your building permit has expired. Before action can be renewed on this project, a new.application and plan review deposit, along with plans and supporting calculations designed to the current California Building Code (2007 edition as of this writing), must be submitted, - reviewed, and approved. ' Yours truly, Greg Butler Building & Safety Manager ot P.O. Box 1504. LA QUINTA, CALIFORNIA 92247-1504 BUILDING & SAFETY DEPARTMENT 78-495 CALLS TAMPICO (760) 777-7012 OF LA QUINTA, CALIFORNIA 92.253 FAX (760) 777-7011 November 12, 2008 Mr. Paul Dewey Sunlite Development, Incorporated PO Box 10668 Palm Desert, CA 92255 RE: Building Permit Extension Request -(5-361'5--Viii-!Strad-a-l. Dear Mr. Dewey: I have reviewed your letter dated October 22, 2008, requesting a time extension for the construction of -the single family dwelling at the above address under Building Permit #07-3031. Our records indicate the following status on thi's permit. Inspection status: Permit issued: 04/28/08 Last successful inspection: NONE 180 -day expiration date: 10/27/08 180 -day extension date: 04/27/09 Under the provisions of 2001- California Building Code Section 106.4.4, your request is hereby granted. Because the Building Code specifies that "no permit shall be extended more than - once," please be advised that unless the project passes its next required inspection on or before Monday, April 27, 2009, your building permit will expire automatically. Your truly, Greg Butler Building & Safety Manager F4 a X-P-achella Valley Unified School .District This Box For District rise only 83-733 Avenue 55, Thermal, CA 92274 DEVELOPER FEES PAID (760).398=5909 - Fax (760),398-1224 AREA: - - AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE: RECBII'T:- CHECK#: ' - INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Hideaway Date: March 22, 2013 Owner's Name: Sedona Homes pPhone No. 760-773-6633 Project Address: 53-615 Via Strada, LaQuinta Project Description: Single Family Dwelling APN: ..77:7-200-006 Tract #: Lot #'s: Type of Development:: Residential RX -1 Commercial Industrial. Toiaf Square Feet ofBuilding Area: ... 5,456. Certification of Applicah't/Owners: The'person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: March 22; 2013. Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE 'FOLLOWING: .(CIRCLE 'ONE) . Education Code , _.;; Gov. Code Project ; Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87. Requirement .Note: Number of Sq.Ft.: 5456 Pursuant to AB 181 any.room additions or,enclosures of 500 Amount per Sq.Ft. $3.20. :. sq.ft. or less are exempt from developer fees. Any mobile homes being,relocated within'the same school district :s .:: Amount Collected $17459.20 jurisdiction are exempt from developer fees. Building Permit Application Completed- Yes/No By: Elsa F. Esqueda, Director. of Facilities and Maintenance am Certificate.is sued by Laurie Howard, Secretary • Signature: C -'C NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective; January 1, 1997, requires that.this District provide (1) _a written notice to the project appellant, at the time*: payment of school fees, mitigation payment or'otheis exactions ("Fees"), of the 90 -day period to protest the imposition of these, Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or: the:validity thereof, commences with the payment of:the fees or performance of any other requirements as described in section 66020 of the Government code: Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part. prior to issuance of a Certificate of Occupancy.- :As.in the latter, the 90 day.s.starts on the date hereof.. This Certificate of Compliance is valid for thirty (30) days from the.date of; issuance. Extension will be granted only for good cause, as determined by' the School District, and up to three (3) such extensions may be granted. MV:c%mvdocs%dcvfees/eeltificate oi'compl ante form updated 3-2007 7 11/2010 RECORDING REQUESTED BY Lawyers Title - IE WHEN RECORDED MAIL THIS DOCUMENT AND TAX STATEMENTS TO: Lance Alacano, President Liot bt McxxAere j Ave - -Ae 6,k- Zt� T4^cko q -*.n o APN: 777-200-006 Escrow No:'- PDi 11032-LT139-CM'; Title No: 612681113 ,DL4'4- oo� - Ato GRANT DEED THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX IS $302.50 x cbmputed�on full value of,-.,prop.erty.co,nveyed...; .- x City of City of La Quinta DOC # 2012-0133035 03/22/2012 12:17 PM Fees: $18.00 Page 1 of 2 Doc T Tax Paid Recorded in Official Records County of Riverside Larry W. Ward Assessor, County Clerk & Recorder "This document was electronically submitted to the County of Riverside for recording" Receipted by: MGREGSTON Space above this FFe 1 FOR A VALUABLE CONSIDERATION' receipt.of which is hereby acknowledged,�,°®N�O, 9 2013 National Bank of Arizona ��/firrs use hereby GRANTS) to , r. :...;,:: - r0 Y JAJ l Sedona Homes, Inc. a California Corporation OPA14 the following described real property in the City of La Quinta County of Riverside, State of CALIFORNIA: For legal descriptionof the real property herein, see Exhibit A attached hereto and made a part hereof. Commonly known as:53615 Via Strada - Lot 254 , La Quinta, CA 92253 Dated: March 19;•2012 STATE OF -Ek- F8RPffR 4ARM0NA ss: COUNTY OF NA2lGn PA I On !AM -61 k0l_,a01a. - before me, T\AlC--e1.2. 1P_k- r • ' , a Notary Public, (here insert name and title oqf the officer) personall" appeare �j\1Ld A•-Zanc.-w;, V���� rsi ter►+ Nationa ank of Arizona 0-0 By: David A. Za , Vice President DAVID A. 1.nCF PR !DENT FOR NWH&IIA".. ?.j� pl; 0 - AF11!l�tv,`� who proved to me on the basis of satisfactory evidence to' be the person(s) whose names) is/are subscribed to the within Instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify •under PENALTY--OF,PERJ.URY—wrider,theJaws of the State of California that the foregoing paragraph is' lellC":EIE'QRIIFR• - r - . true and correct. •Notwy NTAYrana MAR�ACCOOt WITNESS my hand and official seal. MyCommbaronExpkw Febr wy 14, 2016 Signature (This area for notary stamp) MAIL TAX STATEMENTS AS DIRECTED ABOVE EXHIBIT A" All that certain real property situated in the County of Riverside, State of California, described as follows: I Parcel 1: Lot 254 of Amended Tract No. 29894-2, in the City of La Quinta, County of Riverside, State of California, as shown on a subdivision map recorded December 12, 2003, in Book 327, Pages 56 to 88, inclusive of Maps, in the Office of the County Recorder of said County. Parcel 2: Nonexclusive easements for access, ingress, egress, drainage, maintenance, repairs and for other purposes, all as described in the Amended and Restated Declaration of Covenants, Conditions and Restrictions and Reservation of Easements for The Hideaway Owners Association, recorded December 13, 2002, as Instrument No. 2002-745938, of Official Records of said County. Assessor's Parcel Number: 777-200-006-1 El ,HIDEAWAY Ovimers Association April 4, 2013 Mike Tuvell/Sedona Homes 40101 Monterey Avenue, Suite B1-214 Rancho Mirage, CA 92270 RE: Sedona/Lot.254 at 53615 Via Strada Final Design Review ##3 Dear Mr. Tuvell, The Hideaway Design Review Committee (DRC) reviewed the revised final working drawings submitted for your home on Via Strada. The project has been approved to start construction subject to the following stipulations being addressed prior to your request for Setback Observation: 1. The area shown at the trash enclosure must have a planter strip, per the guidelines, rather than having hardscape abut the property line wall. 2. The landscape pots chosen were approved; however, an alternate color should be chosen to avoid a look that is too contemporary. 3. The giant bird of paradise proposed may burn in full sun during the summer months. Please select a more heat resistant plant to use for screening on the south side of the house. 4. The Desert Museum Palo Verde can easily achieve 25-30' in diameter (or greater) which may conflict with the palm on the adjacent property at the rear yard. Please choose an alternate tree that will not cause future maintenance issues. 5. The grade along the raised bond beam allows for more than 18" of the bond beam to be exposed to the golf course. Please revise the grades so no more than 18" will be visible upon completion. Additionally, the pool was redesigned and now appears to be sufficiently screened from the cart path. 6. Thank you for raising the window sills of the three windows located on the right side of the home as well as removing the architectural cutout at the rear stair well. In addition, the committee appreciates that you moved the air conditioning units closer to the street to be more consistent with the location of your neighbor's equipment. It is the understanding of the committee that a gate will not be added at the pool equipment as, under further review, it was found to. be located near the neighbor's same equipment and therefore should not be problematic. The equipment enclosure should also provide some noise protection. 7. The committee appreciates the cut sheets provided for the exterior light fixtures. The committee is recommending removal of the mesh sconces as they are quite large and located high on the building which may be problematic for neighboring homes. The two sconces at the entry and those located on the rear loggia (4) appear to be acceptable if the "Fuego" style and coloring is being utilized. Please submit a sample of the colored lamp shield that will be used for final approval as it is difficult to determine the coloration with only photographs to review. Wattages should also be provided for all exterior architectural and landscape lighting so the committee can confirm compliance with the guidelines. 8. The hardscape materials were approved; however, the committee cautions the use of the glass tiles. While they are very attractive there has been a history of the glass tiles popping off in the summer months when utilized at other residences in the community. Please contact Brook Marshall at (760) 219-8057 or by email at Brook@dc.rr.com with any questions or to schedule your Pre -Construction Meeting at lot once a Permit has been issued. Sincerely, Hideaway Design Review Committee f, - j 8953'*ft42`i"iS art"MbMXCO253 - P-t'n0.393.5210 F: 760.398.5788 ee CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 9/25/2009 Green Sheet approvals are forwarded to the Buildinq & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date: 01 / 28 / 13 Developer: Sunrose Corporation Tract No.: 29894-2 Address(s): Tract Name: The Hideaway Lot No.(s):254 The following are the requirements for Building & Safety Department: 4. 3 4 6 7 CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4, #5 & #7 BELOW TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW WALLS, SIGNS, OTHER: PROVIDE ITEM #6 BELOW 0 Attach Pad Elevation Certificates in compliance with the approved design elevation for building`�&Amaximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 monate). If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad E vation Certificate can be provided. Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils Engineer. Recently rough graded residential developments which have a previously approved geotechnical certification are exempt from this requirement. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots. Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately -with grading plans & are subject to additional requirements. A current PM10 certification number is required. Attach a copy of the rough or precise grading plan to the Public Works Department showing building location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain development plan. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW approved building construction projects require either a WQMP or a completed WQMP exemption form. Approved maps/plans may be viewed at the following link: http://www.la-auinta.org/PlanCheck/m search.aspx I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff. Recommended by: AS-V-�Date: IV Public Works Distribution: ( )Green Sheet to Building & Safety ( ) Green Sheet to Planning Department Declined for approval for reason(s) as follow(s), please correct and resubmit: TAChecklists - Forms & ApplicationsWorns & ApplicationslGREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc V F ^. City of La Quinta - PM10 Fugitive Dust Control Project Information Construction Phase PM10 Agreement M acre/lot or Infill Proiect) Project Information Project Contractor: Sunrose Corporation Project Phase (check one) Construction Demolition Project Name: Sedona Homes Project Tract/Lot Numbers: 29894-2 / Lot 254 Project Street Address: 53-615 Via Strada Total Acres in Active Construction (<1 acre per Lot): 17.887 01 28 1 01 28 13 Anticipated Start Date: / / 3 Anticipated Completion Date: / / PM10 Contact Information Please note: Dust control is required 24 hours a day, 7 days a week, regardless of construction status. Person listed below, is responsible for dust control during business and non -business hours. Name: Mike Tuvell Title- Pres./ Owner Company Name: Sunrose Corporation Mailing Address: 40101 Monterey Ave. #61-214 City, State, ZIP Code: Rancho Mirage, CA 92270 Primary Phone #: 760-773-6633 Fax #: 760-773-6634 24 Hour Emergency Phone#: 760-773-6633 Cell Phone#: 760-702-0119 Email Address: sedonahomes@dc.rr.com PM10 Certificate #: 1 11-12-6640 The above stated property owner (or authorized representative): Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; ❖ Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; ❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; ❖ Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes; ❖ Shall hold harmless t City/County and its representatives from liability for any actions related to this dust control plan or any City/C un y initiated abatement activities. Signature of Property Owner or Authorized TAChecklists - Forms & ApplicationstForms & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc / Date Building Permit Number: 14A Project Description: SFR Exempt; CI (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Pian Plan Submittal Dowl 2/21/2013 Job Sll 53615 Via Strada 11N�, d ix O owners Name Sedona Homes, Inc. clo Sunrose Corp. Number, Street, or Po Box 40101 Monterey Ave., B1-214 city, state. Postal code Rancho Mirage, CA 92270�l sZ � �N00 Owner's Phone Number 760-773-6633 ® �� Owner's E -Mall Address _ y Project Manegera Name Jenny Project Manager's Phone Number 773-6633 Project Managers E -mall Address sedonahomesdMdc,r..com Builder / G Number, Street or city, State, Pos Project Square Sunrose Corporation 40101 Monterey Ave., B1-214 Rancho Mirage, CA 92270 5,988 City Approval By tjr- Date of City Approval rite a Z2--zz Materials To Be Discarded: Product Tons Trash 11.38 Not recyclable Product Tons Asphalt 0.00 Recyclable Masonry (broken) 0.00 Recyclable Brick/Block 0.00 Recyclable . Plaster • 1.20 Recyclable Cardboard 1:98 Recyclable Scrap Metal 0.00 Recyclable Commingled 0.00 Recyclable Tile (floor) 1.02 Recyclable Concrete 0.48 Recyclable Tile (roof) 0.9 Recyclable Drywall 0.35 Recyclable Wood 14.97 Recyclable Donated / Reuse' 0.00 Recyclable Landscape Debris 0.00 Recyclable 'D It c e esms Totals: Recycle Trash Projected Diversion: 20.0 11.4 I understand It is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls oceur.•i hereby certify that completion, Implementation and adherence of the Debris Management Plan (DMP) for the above named project shell guarantee that at least 50% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP Is issued in the name of the property owner(s) and shag remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still Issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner d general contractor shall be kept Informed of the diversion progress through bl-monthly reports. If self hauling, all refu m lal from this project site must be taken to an approved recycler or transfer station. Owner/ Devel r /Project Manager /Superintendent Date Construction Debris Management Plan Summary of Requirements As of January 1, 2011, The Green Building Standards Code (CALGreen) requires that the construction - of most now structures in the State of California comply with sections 4.408 and 5.408 of -the code in -- accordance with Assembly Bill 939 requiring that no more than 50% of jobsite waste be disposed of as trash at local land fill sites and transfer stations. Exceptions may be made for certain projects under certain conditions. The City of La Quinta Is committed to the highest level of environmental respect, to conserving our precious natural resources and setting an example to provide for a better world for generations to come. Recycling helps keep reusable resources out of landfills and will also reduce disposal costs. IMPORTANT: Burtec Waste & Recycling Services is the City's franchise haulers. If you choose to self -haul any recyclables or trash, you must provide copies of all weight tickets and/or receipts from the transfer station, landfill, or recycler as the job progresses. Clean-up companies and other haulers are not permitted to haul waste or recyclables from the City of La Quinta. Self -haul weight tickets should be submitted to: Kenn Stevens, District Environmental Coordinator - kstevens@burrtecdesert.com, or faxed to (760) 340-0417, or mailed to: 41575 Eclectic Street, Palm Desert, Ca 92260. �A Construction Debris Management Plan Summary of Requirements As of January 1, 2011, The Green Building Standards Code (CALGreen) requires that the construction - of most now structures in the State of California comply with sections 4.408 and 5.408 of -the code in -- accordance with Assembly Bill 939 requiring that no more than 50% of jobsite waste be disposed of as trash at local land fill sites and transfer stations. Exceptions may be made for certain projects under certain conditions. The City of La Quinta Is committed to the highest level of environmental respect, to conserving our precious natural resources and setting an example to provide for a better world for generations to come. Recycling helps keep reusable resources out of landfills and will also reduce disposal costs. IMPORTANT: Burtec Waste & Recycling Services is the City's franchise haulers. If you choose to self -haul any recyclables or trash, you must provide copies of all weight tickets and/or receipts from the transfer station, landfill, or recycler as the job progresses. Clean-up companies and other haulers are not permitted to haul waste or recyclables from the City of La Quinta. Self -haul weight tickets should be submitted to: Kenn Stevens, District Environmental Coordinator - kstevens@burrtecdesert.com, or faxed to (760) 340-0417, or mailed to: 41575 Eclectic Street, Palm Desert, Ca 92260. RIVERSIDE COUNTY FIRE DEPARTMENT IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION /I 77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 92211-4131 • Phone (760) 863-8886 Fax (760) 863-7072 ' www.rvcfire.org PROUDLY SERVING THE March 26, 2013 UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: Residential Fire Systems 2871 E. Via Martens - Anaheim, CA BANNING BEAUMONT Re: Residential Fire Sprinkler Plan Review CALIMESA LAQ-I3-RS-019 53-615 Via Strada La Quinta, CA } CANYON LAKE The sprinkler plans you submitted fol= the above referenced project have been reviewed by Riverside County Fire Department Planning & Engineering personnel and are approved with COACHELLA the following conditions: DESERT HOT SPRINGS A minimum of three spare fire sprinklers of each type and temperature rating along with a EASTVALE sprinkler wrench should be located in a spare head cabinet at the system riser or other INDIAN WELLS approved location. / INDIO a J Permanently marked identification signs shall be attached to all control valves. LAKE ELSINORE A warning sign; with minimum'% inch letters, shall be affixed adjacent to the main shutoff valve LA QUINTA and shall state the following: MENIFEE WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a MORENO VALLEY fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system -Age PALM DESERT. without a review of the fire sprinkler system by a fire protections-specialist. 1160 NOT remove this sign. PERRIS z \� The following inspections/tests are required to be witnessed by the Fire Department Planning - RANCHO MIRAGE Division staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and RUBIDOUx csD pumped at normal operating pressure. SAN JACINTO TEMECULA .(b) Final inspection. ' WILDOMAR The Fire Department job card, approved plans and conditions letter must be at the job site or NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection date. BOARD OF SUPERVISORS: All questions regarding the meaning of these conditions should be referred to the Fire BOB BUSTER Department Planning & Engineering staff at (760) 863-8886. DISTRICT 1 JOHN Applicant/installer shall be responsible to contact the Fire Department to schedule inspe ion. TAVAGLIONE DISTRICT 2 JEFF STONE Sincerely, t DISTRICT 3 ` _ Jas n tubble JOHN BENOrr Fire Safety Specialist DISTRICT 4 MARION ASHLEY DISTRICT 5 Patel Burica & Associates, Inc. st'ructLiral engineering February 19, 2013 Sedona Homes 40101 Monterey Ave. RECw`E-1'VED`-' Rancho Mirage, CA 92260 t Re: 53615 Via Strada FEB 1.9 2013 . The Hideaway La Quinta, CA CITY OF LA:QUINTA a COMMUNI7Y DEVELOPMENT' Dear Sir, Two sets of corrected roof truss shop drawings by Spates Fabricators for the subject project were . received by our off ce on February 18, 2013. The drawings have been reviewed for general conforinarice.with the design concept of the structural plans with Delta 2 dated February 18, 2013, and no exception has been taken to their use. The fabrication processes, techniques of construction, coordination of the work with that of any other trade, dimensions, and quantities =with of this review. Since the shop drawings were reviewed only for general the structural plans, unless variations from the structural plans have been clearly indicated, we may not have listed them. Our review of these drawings does not relieve - the roof truss supplier and the framing contractor from complying with the structural plans. Please note that the drawings must be reviewed by the architect and general contractor. If you have any questions please call 714.547.1115 ext 205. j CITY 0FLA- QUINTA Sincerely, BUILDING & SAFEWDEPM . APPROVED .w._1 Patel Burica &Associates, Inc. FOR CONSTRUCTION �G DA Tel I' Brad Fellers, P.E. \\SERVER\PBAServer\Projects\665 SCA (53615 Via Strada)\665 SCA Review Truss 02 (Spates - Approved)'doc A '� gni '' 832 W. Town & Country Road Orange, California 92868 { r T_4�; — _ Tel: 714.547.1115 • Fax: 714.547.1141 i www.PBAstruc'tural.com ;.• ,. 'ti - Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/12/2013 Electronicallv Sianed at CalCERTS.com by Frank Stolz (South Coast Architects, Inc.) 2/12/2013 ;.1 L.. R PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1211212013 Date Project Address 53-615 Via Strada La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,477 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST El Yes Q No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. EI Yes 0 No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION • - • I, Area Special Construction Type Cavity. ( Feature Part 2 of 5 Status Roof Wood Framed Attic R-38 5,867 Radiant Barrieew Wall Wood Framed R-21 7,116 NJW Slab Unheated Slab -on -Grade None 5,349 Perim -- 526' ew Door Opaque Door None 24 E&J New COMA41 10.,Ft` ni DFy 4. -FENESTRATION:`` 4 ° U. Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status LeR (E) 305.7 ! k*, :0.390 0.39 none none Bug Screen New Rear(S) 481.8 ' 0.390 ;0.39.,�none .. - none Bug Screen, New Right (K9 �` r•;" 415.4 ,0.390{ R 039 ;none .: f'..f -4n - Bug Screerr,`, New Front (N) yr'; X462 2... (� Bug Screen �"' "'New =- Left (SE),-,,-; -' 1'17 0 0.3 3 n e }Bug Screen>>~ 1 New tj DEP-�T gym. VP t3 �5rolt-- 1' HVAC SYSTEMS L2 (jab V: Ot . Heating,Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 1 Split Heat Pump 8.00 HSPF • Split Heat Pump 14.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted, Attic, Ceiling Ins, vented 4.2 New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 4.2 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 4.2 New WATER HEATING - Ot . Type Gallons Min. Eff Distribution Status 2 Large Gas 100 0.99 All Pipes Ins New EnergyPro 5.1 by EnergySoft User Number: 6712 - RunCode: 2012-12-20708:21:45 ID: Pae 1 of 10 Reg: 213-N0008933A-000000000-0000 Registration Date/Time: 2013/02/12 10:31:05 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/12/2013 Electronically Signed at CalCERTS.com by Frank Stolz (South Coast Architects, Inc.) 2/12/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2112/2013 Project Address 53-615 Via Strada La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,477 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features — If Yes; see Part 2 of 5 of this form for details. INSULATION Area . Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION:: ' U- - Exterior Orientation.. "., Area Factor SHGC Overhang Sidefins Shades Status 110 .•P .� w °\, ....Y k& .. :.... b.F:T "gyp b: +.. .. RI(Fi.. 4.. 8n. ...I, w 01 ... �yy=«e Fl $ `' «� .• . «be�A r•`l A Fg!4 4 i '. 4..'../..iC{YY�.A �£', HVAC SYSTEMS Qty.- Heating Min. Eff Cooling Min. Eff Thermostat. Status 1 , Split Heat Pump 8.00 HSPF • Split Heat Pump 14.0 SEER Setback New 1 Split Heat Pump 8.00 HSPF Split Heat Pump 14.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 5 Ducted .'Ducted Attic, Ceiling Ins, vented . 8.0 New HVAC 6 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING t Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number.' 6712 RunCode: 2012-12-20708:21:45. ID: Page 2 of 10 Reg: 213-N0008933A-000000000-0000 Registration Date/Time: 2013/02/12 10:31:05 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.c6m - 2/12/2013 Electronically Signed at CalCERTS.com by Frank Stolz'(South Coast Architects,'Inc.) 2/12/2013 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Building Type ® Single Family ❑ Addition Alone Date Sedona Homes ❑ Multi Family_ ❑ Existing+ Addition/Alteration 1211212013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention•to the items specified in this checklist. These items require special written . justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the s ecial justification and documentation submitted.. - The DHW System Bradford -White Corp. EF -100T -150-3N is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non-closable'area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design -Verify Thermal Mass: 1,032.0 ft2 Covered Slab Floor, 3.500" thick at Owners Suite, HIGH MASS Design - Verify Thermal Mass: 460.0 ft' Exposed Slab Floor, 3.500" thick at Owners Suite . The HVAC System HVAC 2 & 3 must serve only Living Areas,,, The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 636.0 IF Covered Slab Floor, 3.500" thick at Great Dining Kitchen HIGH MASS Design - Verify Thermal Mass: 2,302.0 ft2 Exposed Slab Floor, 3.500" thick at Great Dining Kitchen r The HVAC System HVAC 4 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se crate thermostat. In addition the 6ir.; flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH°MASS Design - Verify TheimallMass: 228.0 ft2 Covered Slab Floor, 3.500" thick at Guest 2 HIGH MASS Design - Verify Thermaldss: 275.0 ft2 Exposed Slab Floor, 3.500" thick at Guest 2 The HVAC System HVAC 5 must serve only Sleeping Areas. 'r The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the airf l!v a uirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS DesignVenfy Thermal Mass 296 O tt' Covered Slab: Floor 3 500 thic%cat Guest 1 N� sFyyw.. .'Y} �.:Z*�. `7DTPe.ex`�"F"b b`i ..y HIGH MASSA 6sign - Verify Theg4rmaI as 120'0`ftz Exposed S1db,F1oor 3.500 thick at Guest 1 f km v & • CW Mgr § £.w dsa'rk - c 'E' . '4'` t W e HER REQUIRED 1/ERIFICAT1ION 4� iZiPV secs �� ver)�ftcatlon by acertifled'HERS Rater TheMlnspector must�recei"ve a Items tlon,�requ)re field testing and/o mthls com leted CF -_4R form for each of,the�measures listed below for final tot- even: The Cooling System Carrier includes credit: for a 11.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVACitystem HVAC 1 orporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System.' The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. k - ' The Cooling System Carrier includes credit for a 11.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.. The HVAC System HVAC 2 & 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. a The HVAC System HVAC 2 & 3 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Mitsubishi includes credit for a 11.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ene Pro 5.1 6 Ene Soft User Number 6712 RunCode: 2012-12-20708:21:45 ID: Pace 3 of 10 Reg: 213-N0008933A-000000000-0000 RegistrationDate/Time: 2013/02/12 10:31:05 HERS Provider: CalCERTS,'Inc M Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/12/2013 Electronically Signed at CalCERTS.com by Frank Stolz (South Coast Architects, inc.) 2/12/2013 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Building Type ® Single Family ❑ Addition Alone Date Sedona Homes ❑ Multi Family ❑ Existing+ Addition/Alteration 1'211212013 SPECIAL FEATURES INSPECTION CHECKLIST' The enforcement agency should pay special attention to the items specified in this checklist.. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System HVAC 6 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow re uirements and fan watt draw re uirements in Residential Appendix RA3.3 must be met. The Roof R-38 Roof(R.38.2x 14.16)C includes credit for a Radiant l3anier that isContinuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. ` yN o y. Rte,ZI ^�3 E HERSREQUIRED �/E',RIFICATION�c �:`` r` � �M. ter_ � i Rvenater Th nspector must reeetve a oomSletedlCF 4R form for each of the measures listedtbelow for'fmalto�be The Cooling System Mitsubishi includes credit for a 11.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. Th; Oil HVAC,'System HVAC 5 incorporates HERS Verified Refrigerant Charge or a'Charge Indicator Display., The HVAC System HVAC 5 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Mitsubishi includes credit for a 11.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 6 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. ` The HVAC System HVAC 6 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. r The HVAC System HVAC 6 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ene Pro 5.1 b Ene Soft User Number: 6712 RunCode: 2012-12-20708:21:45. ' ID: Page 4 of 10 Reg: 213-N0008933A-000000000-0000 Registration Date/Time: 2013/02/12'10:31:05. HERS Provider: CalCERTS, Inc ' � .y Vii. .- 4 • - �, T.• , ', '' • , - Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 2/12/2013 Electronically Signed at Ca10ERTS.com by Frank Stolz (South Coast Architects, Inc.) 2/12/2013 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Sedona Homes ❑ Multi Family ❑ Existing+ Addition/Alteration 1211212013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating, '5.86 4.02 1.84 Space Cooling 61.48 58.28 3.20 _ Fans 12.41 18.08 75.67 - Domestic Hot Water 5.30 2.81 - `� "2.49 Pumps 0.00 0.00. 0.00 - Totals 85.05 83.19: 1.86 Percent Better Than Standard: 2.2 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 6deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: - _ - 1.00 - (N) 2,312 462 Fuel Available at Site: Natural Gas (E) 2,436 423 Raised Floor Area: 0 (S) 1,946 482 Slab on Grade Area: 5,349 (Vt� 2,228 415 Average Ceiling Height: # ' . 12.9 Roof 5,867 0 0.39 Fenestration Average U -Factor: , TOTAL: 1,782 Avefa a SHGC `. .0.39 Fenestration/CFA Ratio: 275 REMARKS' = t s - . S f � � I 3✓P' X' Fp � a STATEMENT OF COMPLIANCE This'certificate of bbi mplianceilists;the building features and. specifications needed to comply with Title 24 ;Parts 1'th:e Administrative Regulations and Part 6 the Efficiency Standards of thekCalfornia Code of Regulations.., r The documentation author hereby certifies that the documentation is accurate and complete. . F Documentation Author Company Scott Design and Title 24, Inc, 2/12/2013 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby, certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company South Coast Architects - Address 13 Corporate Plaza STE 210 _ Name South Coast Architects City/State/Zip New Port Beach, CA 92660 - Phone (949) 720-7022 Signed, License # Date EnemvPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2012-12-20708:21:45 ID: Page 5 of 10 Reg: 213-N0008933A-000000000-0000' Registration Date/Time: 2013/02/12 10:31:05 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/12/2013 •- Electronically Signed at CalCERTS.com by Frank Stolz (South Coast Architects, inc.) 2/12/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of, 5 CF -1 R Project Name Sedona Homes Building Type m Single Family [3Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2/12/2013 OPAQUE SURFACE DETAILS Surface u- Insulation ' Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Aim Tilt Status 4 Location/Comments Roof 1,492 0.026 R-38 0 20 New 4.2.1-A9 Owners Suite Wall 336 0.069 R-21 0 90 New 4.3.1-A6 Owners Suite Wall 542 0.069 R-21 90 90 New 4.3.1-A6 .. Owners Suite Wall 267 0.069 R-21 180 90 New 4.3.1-A6 Owners Suite Wall 275 0.069 R-21 2701 90 1 New 4.3.1-A6 . Owners Suite Slab 1,032 0.730 None 0 " 180 New 4.4.7-A1 Owners Suite Slab 460 0.730 None 0 180 New 4.4.7-A1 Owners Suite Roof 2,328 0.026 R-38 6 20 New 4.2.1-A9 ' Great Dining Kitchen Wall 448 0.069 R-21 6 90 New 4.3.1-A6 Great Dining Kitchen Wall 665 0.069 R-21 90 90 New 4.3.1-A6 Great Dining Kitchen Door 24 0.500 None 90 90 New 4.5.1-A4 Great Dining Kitchen Wall 143 0.069 R-21 135 90 New 4.3.1-A6 Great Dining Kitchen Wall 453 0.069 R-21 � 180 -90 New . 4.3.1-A6 Great Dining Kitchen Wall 286 0.069 R-21 225 90 New 4.3.1=A6 Great Dining Kitchen Wall 202 0.069 R-21 270 90 New 4.3.1-A6 Great Dining Kitchen Wall 156 0.069 R-21 315 90 New. 14.3.1-A6 Great Dining Kitchen FENESTRATION SURFACE:DETAILS ID Type Area U Facfor SHGC • Azm Status w Glazing Type Location/Comments 1 Window 56.1: 0.390 NFRC . 0.39 NFRC 90 New .. Window Dual Owners Suite 2.:: ,l ndow 33.6 0.390 NF,, C - 0.39 NFRC 90 New Window Dual Owners Suite .3 Window +rye 91.6 0.390,NFRC 0.39 NFRC 90 New Window Dual . Owners Suite 4. Window 4.0 0.390 NFRC, 0.39 NFRC 90 New- > Window Dual Owners Suite . 5A Window..,,,..-. ;6.6 0.390 NFRC . LL, 0 39 ,NFRC ..._ ' .....9A0 New___. Window Dual ..... Owners Suite . ,. 6 window 66 0.390 `NFRC ,0 39 ;NFRC s 90'New� window Duals ffi ;Owners Suite 7 Window," " %, 6,°6 OK390 'NFR,C F.0 39 'NFRC 90 'New t rtl ndow Dual ?;+ ,.. . 'Ownecs_Suite 8 Window 6.6s0390,NFRC, '' 0.39 NFRC}90 New , -. wridowDual 4 _.:Owners Suite 9 .. , wndowDua(s, r Window ,6�6 Q'390 ;N,,F,RC 0': 0.39 NFRC '60 New , "" [Owner$;Suite s:r• 10 Window 6 6, ';0 390, NFRCs .. 0 39 NFRC X186; (New, .. Window Dual, A,< Owners;Suite 11 LYindow 6 6s 0 39,0 °NF_RC 0 39' NFRC 180' New,'r ' !W dow Dual a ", . Qwners'Suife "` } ; 12'' Window . „6 6 0 390. 'NFRC.'0 39 NFRC;: ; , 180, :New " _.: Windo..w Dual1t: " ,:-.. ` Owners Suite 13 ' Window ! ; ..6.6 0.390 NFRC 0.39 NFRC 180 New Window Dual Owners Suite 14 - Window "� 6.6 0.390 NFRC 0.39 NFRC • 180 New Window Dual Owners Suite 15 ^• Window 1,6.6 0.390 NFRC 0.39 NFRC 180 New Window Dual Owners Suite 16 " Window 57.2; �._0.390,fNFRC 0.39 NFRC 180 New Window Dual Owners Suite (1) U -Factor Type +;116-A'= Default Table from Standards, NFRC = Labeled Value 2 SHGC T e:1:1'.6:13 =;Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Ove hang Left Fin Right Fin ` Exterior Shade Type' SHGC HqA WdLen H t LExt'- RExt Dist Len. H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 ' 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 ' a 7 Bug Screen 0.76 8 Bug Screen -0.76 9 Bug Screen 0.76 y ` 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 - 13 Bug Screen 0.76 14 Bug Screen 0.76 15 lBug Screen 0.76 16 JBug Screen 0.76 EnemyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-12-20708:21:45 ID: Page 6 of 10 Reg: 213-N0008933A-000000000-0000 Registration Date/Time: 2013/02/12 10:31:05 HERS Provider: CalCERTS, Inc L Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 2/12/2013 Electronicallv Sianed at CalCERTS.com by Frank Stolz (South Coast Architects, Inc.) 2/12/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone , . ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2112/2013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 636 0.730 None 0 180 New 4.4.7-A 1 Great DiningKitchen Slab 2,302 0.730 None 0 186 New 4.4.7-A1 Great DiningKitchen Roof 563 0.026 R-38 0 20 New 4.2.1-A9 Guest 2 Wall 426 0.069 R-21 0 90 New 4.3.1-A6 Guest 2 Wall 396 0.069 R-21 90 '90 New 4.3.1-A6 - Guesf2 Wall 162 0.069 R-21 180 90 New 4.3.1-A6 Guest 2 Wall 468 0.069 R-21 270 90 New 4.3.1-A6 Guest 2 Slab 228 0.730 None 0 180 New 4.4.7-A 1 Guest 2 Slab 275 • 0.730 None 0 180 New 4.4.7-A1 Guest 2 Roof 416 0.026 R-38 0 20 New 4.2.1-A9 Guest 1 Wall 320 0.069 R-21 0 90 New 4.3.1-A6 Guest 1 Wall 164 0.069 R-21 90 90 New 4.3.1-A6 Guest 1 Wall 356 0.069 R-21 180 90 New 4.3.1-A6 Guest 1 Wall 180 0.069.R-21 270 90 New 4.3.1-A6 Guest 1 Slab 296 0.730 None 0 180 New 4.4.7-A1 Guest 1 Slab 120 0.730 None' 0 180 New 4.4.7-A1 Guest 1 FENESTRATION SURFACE,DETAILS ID Type Area --.AJ-Fa orSHGCz Azm Status Glazing Type Location/Comments 17 Window 6.6: ' 0.390 NFRC 0.39 NFRC 270 New Window Dual Owners Suite 18-: Window 6.6 . 0.390 'NFRC 0.39 NFRC 270 New Window Dual Owners Suite 19 Window 6.6 0.390 NFRC 0.39 NFRC 270 New Window Dual Owners Suite 20, Window 6.6 0.390 NFRC 0.39 NFRC 270 New 'Window Dual Owners Suite 21."21 Window,,,,,,_.- „ 6.6 0.390 NFRC �0 39. NFRC ._ _ 270 New.... Window Dual ..._ .,, ,Owners Suite 22T'::.:Windows _ � X270 New "��� � " ''' ;�� 3 `"- , ;Owners Suite 24'0 0.390 NFRCp0:39' NFRC 'k WindowDualf , ; . 23 ,endow x;48:0 0 390 ,NF. RC. ` 4 0°39 `NFRC 1�; ,4�:270 :Newer window,1; 'Owners -Suite 24 :Window'` 24.0 X0.390, "NFRC , ; '! 0.39 NFRC , ;270 New window Dual rowners Suite 25 Window 58F0` X0390 NFRC 0.39 NFRC °_270 New ' wndowDu81r _ u NW Own 26 Window f58 3 ';0 390 :NFRC 1 0.391±NFRC¢ X270 Mw**4 1 .WndoW Dual.;'"'" ' ' 0Wn6rs,Suit0t. . -i 27 Window $.:: 37:;1f 0390; NFRC X0.39'`NFRC-'5 46 New _ W.rndow"Dual ": °' ;Great Di i Kdchen 28;1.Wndow O ,New Window Dual :' y Great Dining Kitchen " ;: 2401. 0 :; 0.390 .NFRC rt"``0.39` NFRC T 29 Window: 30.6 0.390 NFRC . ; '"`" 0.39 NFRC 0 New Window Dual Great Dining Kitchen 30. Window 1^26.6 6.390 NFRC 0.39 NFRC 90 New Window Dual Great Dining Kitchen 31 window 25:9, 0.390 'NFRC 0.39 NFRC 90 New Window Dual Great Dining Kitchen 32 Window 6.3; k. 0.390: NFRC 0.39 NFRC 90 New Window Dual Great Dining Kitchen (1) U -Factor Type'', --11.6-A =Defauft'Table from Standards, NFRC = Labeled Value 2 SHGC Type: ` 0.6-B = Qefauft Table from Standards, NFRC =Labeled Value EXTERIOR SHADING DETAILS ID Window Ove rhang' Left Fin Exterior Shade Type - SHGC H t . Wd Len H t LExt RExt Dist Len Ri ht in H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 - 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bu Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 IBug Screen 0.76 32 IBug Screen 0.76 EnergyPro 5.1 by EnerqvSoft User Number: 6712. RunCode: 2012-12-20708:21:45 ID: Pae 7 of 10 Reg: 213-N0008933A-000000000-0000 Registration Date/Time: 2013/02/12 10:31:05 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 2/12/2013 Electronically Signed at CalCERTS.com by Frank Stolz (South Coast Architects, Inc.) 2/12/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone ❑ Multi Family, ❑ Existing+ Addition/Alteration Date 1211212013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,128 0.026 R-38 0 20 New 4.2.1-A9 2nd Floor Wall 200 0.069 R-21 0 90 New 4.3.1-A6 2nd Floor Wall 120 0.069 R-21 46 90 New 4.3.1-A6 2nd Floor Wall 80 0.069 R-21 90 90 New 4.3.1-A6 2nd Floor Wall 152 0.669 R-21 270 90 New 4.3.1-A6 2nd Floor Wall 120 0.069 R-21 270 90 New - 4.3.1-A6 2nd Floor Wall 140 0.069 R-21 270 90 New 4.3.1-A6 2nd Floor Wall 120 0.069 R-21 2701 90 New 4.3.1-A6 2nd Floor FENESTRATION SURFACE„DETAILS ID ape Area U-Fadtor SHGC2 Status GlazingType Location/Comments 33 Window 6.3 '' 0.390 NFRC 0.39 NFRC New Window Dual Great Dining Kitchen ;; 34_,. Window _..6.3 0.390 .NFRC 0.39 NFRC New Window Dual, Great Dining Kitchen 7135 35 Window r117.d 0.390 ',NFRC 0.39 NFRC New ' Window DualGreat Dinin Kitchen 36. Window 63.0 0.390 NFRC 0.39 NFRC New Window Dual Great Dining Kitchen 37.N Window. - ,, - 240.0 0.390 NFRC.21- ,0.39- NFRC .. 180 New... " Window Dual.:... v ;;:.. ,Great Dining Kitchen 38 .': Wndow, , 3:2, 0.390 `NFRC ,NFRC 270 `New w11 Window Dual - � i ` l" ';G�eat Dining Kitchen 39 Window, ?; 6.3 0.390 'NFRC, r., 0 39 `NERC . 270, ;Newt. ':^^ Window Dual, ;tea ? Great. Dining Kitchen 40 n � ' Great D�nin Kdchen wrilow' 6 3F,�0 390 `NFRC ;:' 0.39 NERC X270 New , .: Window Dual„ g - 41 Wndow 6/3` 0°390 ,NERC 0.39 NERC I_270 ,New ,,• ,WndowrDual 'Great D�ning Kitchen 42 Wndow r , f, a1, r' ,�18 0,� „i', 0 390 NF C '� 0 39� NERC a�f : 0 (New„�,jl � Window Dual 43 .'ndow>;18 O.t0 390' NFRC 0.39;'NFRC 0. New? ;Wrndow Dual ,^n .r� Guest 2: ! *; 44:` Window. 18 0 :;, 0 390. ;NERC, 0 39:, :NERC"; ...0 ,New , ., Wndow Dual.".,. , ` "Guest 2 46 Window -.6.0 0.396 NFRC!.:;:-;'-T "W30 'NFRC 0 New Window Dual Guest 2 _�--: 46.. Window'::- ---,0.0 0.390 NFRC 0.39 NFRC 0 New Window Dual Guest 2 471.. Wndow 60; 0.390 'NFRC 0.39 NFRC 0 New Window Dual Guest 2 48 " Window "6.;0" k,_0.390; NFRC 0.39 NFRC ,0 New Window Dual Guest 2 (1) Ll -Factor Type "116-A = Default Table from Standards; NFRC = Labeled Value 2 SHGC Type: "' 11i6 8 =DefauR Table from Standards,'NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Ove hanq Left Fin Ri ht Fin Exterior Shade Type SHGC H t Wd Len ' H t LExt . RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 - 37 Bug Screen 0.76 38 Bug Screen 6.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 . 46 Bug Screen 0.76 47 JBug Screen 0.761 1- 48 JBug Screen 1 0.76 Ene Pro 5.1 by EnerqySoft User Number: 6712 _ RunCode: 2012-12-20708:21:45 ID: Page 8 of 10 Reg: 213-N0008933A-000000000-0000 Registration Date/Time: 2013/02/12 10:31:05, HERS Provider: Ca10ERTS, Inc a Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/12/2013 Electronically Signed at CalCERTS.com by Frank Stolz (South'Coast Architects, Inc.) 2/12/2013 a CERTIFICATE OF COMPLIANCE:. "Residential Part 4 of 5 CF -1 R Project Name Sedona Homes Building Type O Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2112/2013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix ry.pe Area Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE; DETAILS' ID Type Area U Facfor SHGC Azm Status Glazing Type Location/Comments 49 Window 42.0. 0.390 NERC 0.39 NFRC 180 New Window Dual Guest 2 50 76.5 0.390 ,NERC . 6.39 NFRC 0 New Window Dual Guest 1 .Window 51 Window � 4.0 0.390 'NFRC 0.39 NFRC 90 New Window Dual Guest 1 52 Window 4.0 0.390 NFRC. 0.39 NFRC 90 New Window Dual Guest 1 53.N Window 1, 4.0 0.390 NFRC 0.39 NFRC Z_90 New Window Dual _. ..Guest 1 54 Windows+. - -_'V--4 0 0.390 `NFRC,+. 0.39 ;NFRC. 3 ` X90; New Window Dualf b Guest 1 55 Window X40.0 0x390 ,NF. RC - 0.39 'NFRC ,# x:.180 :'New,° f Window Dual _' j * Guest 1 ,. 2nd Floor''_ T - »�._.� 56 Window;' 21.5 �,0390,'NFRC ., -�` 0.39 NFR'C'of 270 New 1WndowDualin' '� "�,': t 57 Window 1,715 0 390 ;NFRC .0.39 NFRC•; 270 ,New Window�Dual t : '2nd Floor ; 2nd Flooi 58 VYndow X9.0, 0 3.O, NFRC 1 '.' 0 39,! NF,RCi X270 INew q @ Window Dual.a' �t 59 :. VYndow'' 60.'6 T0779_0. `NFRC' x0.39 NFRC," �27.0`'<New, Windo'w.Dua! '.�� 2nd;F,loor,"ipr a , # F r. a (1) U -Factor Type: " • 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 'Al 6,13 =-Defauft Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ' Window Ove hanq Left Fin Ri ht Fin ID Exterior Shade Type 'SHGC H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 - ' 55 Bug Screen 0.76 .56 Bug Screen 0.76 57 Bug Screen 0.76 58 Bug Screen 0.76 59 Bug Screen 0.76 EneMyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2012-12-20708:21:45 ID: Page 9 of 10 Reg: 213-N0008933A-000000000-0000 Registration Date/Time: 2013/02/12 10:31:05 'HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 2/12/2013 Electronicallv Sinned at CalCERTS.com by Frank Stolz (South Coast Architects, inc.) 2/12/2013 CERTIFICATE OF COMPLIANCE: Residential'-; (Part,5 of 5 CF -1 R Project Name Sedona Homes Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 211212013 BUILDING ZONE INFORMATION Floor Area ff System Name Zone Name New Existing Altered Removed Volume Year Built HVAC 1 Owners Suite 1,492 17,904 HVAC 2 8 3 Great Dining Kitchen 2,938 41,132 HVAC 4 Guest 2 503 6,036 HVAC 5 Guest 1 416 4,992 HVAC 6 2nd Floor 1,128 13,536 It Totals 6,477 0 0 0 HVAC SYSTEMS . . -,.-..,!System Name,,` Qt `. '�,:Heatinq Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 A Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 2 & 3 2 " Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 4 _ _. °^? 1Heat,Pum ; '8:00 WSPF SpNt Heat -Pum 14;OrvSEER; Settiack•, . New HVAC 5 . : '". '`' 1 S lit Heat Pum 8k00 HSPF, S :IitjlHeatfPhUm `��k., f40 SEER Setback' i. New HVAC- ,` ' ' 1 tSpld'Heat Pump "' ;8.00'HSPF .§plat Heat Pump f14.O:.SEER, Setback ` ,�� "=-_ :, New gg, y HVAC DISTRIBUTION ' ` Ar If % ;' �.:, a �. z*� �D`uct V. Ducts : r System Name ^� �" r Heatir .: Coohn .Duct Location - R Value Tested? Status HVAC 1;, Ducted f Ducted Attic, Ceiling Ins, vented 4.2 m New HVAC 2'& 3 , �_ Ducted ' : Ducted '" Attic, Ceiling Ins, vented 4.2 m New HVAC 4 ..: .' Ducted Ducted ' Attic, Ceiling Ins, vented 4.2 d New HVAC5 . "4Ducted ...;, Ducted Attic, Ceiling Ins, vented 8.01 New HVAC 6 Ducted .� Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS` - S stem Name Qty. Type ;Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White Corp. EF -1 2 Large Gas All Pipes Ins '.150,000 160 0.99 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING, Control Hot Water Piping Length ff o N a c S stem Name Pipe Length Pipe Diameter Insula Thick. Qty.. HP Plenum Outside Buried O , EnergyPro5lbyEnergySoft User Number: 6712 RunCode: 2012-12-20708:21:45 ID: Pae 10 of 10 Reg: 213-N0008933A-000000000-0000 Registration Date/Time: 2013/02/12 10:31:05 HERS Provider: CalCERTS, Inc BUILDING ENERGY ANALYSIS REPORT PROJECT: Sedona Homes 53-615 Via Strada La Quinta, CA 92253 Project Designer: South Coast Architects 13 Corporate Plaza STE 210 New Port Beach, CA 92660 (949) 720-7022 Report Prepared by: Tirn'Scott Scott Design and Title 24, Inc, ,� 77-085 Michigan Drive RECEI Palm DesertCa 92211. ' VED 760 200-4780 ( ) FEB192 013 comx Job Number: CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION, Date: 'DAI BY 2/13/2013 2. The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary - 13 HVAC System Heating and Cooling Loads Summary 16 Room Load Summary 21 Room Heating Peak Loads, 26 Room Cooling Peak Loads 31 EnergyPro 5.1 by EnergySoft Job Number: ID: User Number: 6712 0 • i PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Sedona Homes Building Type o Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2113/2013 Project Address 53-615 Via Strada La Quinta California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 6,477 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 5,867 Radiant Barrier New Wall Wood Framed R-21 7,135 New Slab Unheated Slab -on -Grade None 5,349 Perim = 526' New Door Opaque Door None 24 New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Left (E) 305.7 0.390 0.39 none none Bug Screen New Rear (S) 481.8 0.390 0.39 none none Bug Screen New Right (lM 396.4 0.390 0.39 none none Bug Screen New Front (N) 462.2 0.390 0.39 none none Bug Screen New Left (SE) 117.0 0.390 0.39 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New 1 Split Heat Pump 8.00 HSPF Split Heat Pump 14.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 4.2 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 4.2 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 2 Large Gas 100 0.99 All Pipes Ins New EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Page 3 of 38 • 0 01 PERFORMANCE CERTIFICATE: Residential..... Part 1 of 5 CF -1 R Project Name Sedona Homes Building Type o Single Family ❑ Addition Alone O Multi Family ❑ Existing+ Addition/Alteration 1211312013 Date Project Address 53-615 Via Strada La Quinta California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 6,477 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST , ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity ( Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 8.00 HSPF Split Heat Pump 14.0 SEER Setback New 1 Split Heat Pump 8.00 HSPF Split Heat Pump 14.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location -R-Value Status HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 6 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status —EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Page 4 of 38 • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Sedona Homes Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2113/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford -White Corp. EF -100T -150-3N is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 1,032.0 ft' Covered Slab Floor, 3.500" thick at Owners Suite HIGH MASS Design - Verify Thermal Mass: 460.0 ft' Exposed Slab Floor, 3.500" thick at Owners Suite The HVAC System HVAC 2 & 3 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a sFrate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HH MASS Design -Verify Thermal Mass: 636.0 ft' Covered Slab Floor, 3.500" thick at Great Dining Kitchen HIGH MASS Design - Verify Thermal Mass: 2,302.0 ft' Exposed Slab Floor, 3.500" thick at Great Dining Kitchen The HVAC System HVAC 4 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 228.0 ft' Covered Slab Floor, 3.500" thick at Guest 2 HIGH MASS Design - Verify Thermal Mass: 275.0 ft' Exposed Slab Floor, 3.500" thick at Guest 2 The HVAC System HVAC 5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 296.0 ft' Covered Slab Floor, 3.500" thick at Guest 1 HIGH MASS Design - Verify Thermal Mass: 120.0 ft' Exposed Slab Floor, 3.500" thick at Guest 1 HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -413 form for each of the measures listed below for final to be given. The Cooling System Carrier includes credit fora 11.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier includes credit for a 11.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The I4VAC System HVAC 2 & 3 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 & 3 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 2 & 3 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Mitsubishi includes credit for a 11.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 4 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Energ YPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Page 5 of 38 0 • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name . Sedona Homes Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2113/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the s ecial iustification and documentation submitted. The HVAC System HVAC 6 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. The Roof R-38 Roof(R.38.2x 14.16)C includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Mitsubishi includes credit for a 11.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 5 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Mitsubishi includes credit for a 11.5 EER Condenser A certified HERS rater must field verify the installation of the correct Condenser The HVAC System HVAC 6 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 6 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 6 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Energ YPro 5.1 by Ene Soft User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Pa e 6 of 38 • 0 • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family O Addition Alone Date Sedona Homes 1 ❑ Multi Family O Existing+ Addition/Alteration 2113/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 5.86 4.02 1.84 Space Cooling 61.48 57.93 3.55 Fans 12.41 .17.98 -5.57 ' Domestic Hot Water 5.30 2.81 2.49 Pumps 0.00 0.00 - 0.00 Totals 85.05 82.74 2.30 Percent Better Than Standard: 2.7% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 2,312 462 Fuel Available at Site: Natural Gas (E) 2,436 423 Raised Floor Area: 0 (S) 1,946 482 Slab on Grade Area: - 5,349' (W 2,228 396 Average Ceiling Height: 12.9 '- Roof 5,867 0 Fenestration Average U -Factor: 0.39 TOTAL: 1,763 Average SHGC: 0.39 Fenestration/CFA Ratio: 27.2% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and compl e. Documentation Author Company Scott Design and Title 24, Inc, 2/13/2013 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company South Coast Architects Address 13 Corporate Plaza STE 210 Name South Coast Architects City/State/Zip New Port Beach, CA 92660 Phone (949) 720-7022 Signed License # Date Erie Pro 5.1 b Ene Soft User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Pa e 7 of 38 • C] CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Sedona Homes Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1211312013 OPAQUE SURFACE DETAILS Surface TvDe Area U- Insulation Joint Appendix Factor Cavitv Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,492 0.026 R-38 0 20 New 4.2.1-A9 Owners Suite Wall 336 0.069 R-21 0 90 New 4.3.1-A6 Owners Suite Wall 542 0.069 R-21 90 90 New 4.3.1-A6 Owners Suite Wall 267 0.069 R-21 180 90 New 4.3.1-A6 Owners Suite Wall 275 0.069 R-21 270 90 New 4.3.1-A6 Owners Suite Slab 1,032 0.730 None 0 180 New 4.4.7-A1 Owners Suite Slab 460 0.730 None 0 180 New 4.4.7-A1 Owners Suite Roof 2,328 0.026 R-38 0 20 New 4.2.1-A9 Great Dining Kitchen Wall 448 0.069 R-21 0 90 New 4.3.1-A6 Great Dining Kitchen Wall 665 0.069 R-21 90 90 New 4.3.1-A6 Great Dining Kitchen Door 24 0.500 None 90 90 New 4.5.1-A4 Great Dining Kitchen Wall 143 0.069 R-21 135 90 New 4.3.1-A6 Great Dining Kitchen Wall 453 0.069 R-21 180 90 New 4.3.1-A6 Great Dining Kitchen Wall 286 0.069 R-21 225 90 New 4.3.1-A6 Great Dining Kitchen Wall 202 0.069 0-21 270 90 New 4.3.1-A6 Great DiningKitchen Wall 156 0.069 R-21 315 90 New 4.3.1-A6 Great Dining Kitchen FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 56.1 0.390 NFRC 0.39 NFRC 90 New Window Dual Owners Suite 2 Window 33.6 0.390 NFRC 0.39 NFRC 90 New Window Dual Owners Suite 3 Window 91.6 0.390 NFRC 0.39 NFRC 90 New Window Dual Owners Suite 4 Window 4.0 0.390 NFRC 0.39 NFRC 90 New Window Dual Owners Suite 5 Window 6.6 0.390 NFRC 0.39 NFRC 90 New Window Dual Owners Suite 6 Window 6.6 0.390 NFRC 0.39 NFRC 90 New Window Dual Owners Suite 7 Window 6.6 0.390 NFRC 0.39 NFRC 90 New Window Dual Owners Suite 8 Window 6.6 0.390 NFRC 0.39 NFRC 90 New Window Dual Owners Suite 9 Window 6.6 0.390 NFRC 0.39 NFRC 90 New Window Dual Owners Suite 10 Window 6.6 0.390 NFRC 0.39 NFRC 180 New Window Dual Owners Suite 11 Window 6.6 0.390 NFRC 0.39 NFRC 180 New Window Dual Owners Suite 12 Window 6.6 0.390 NFRC 0.39 NFRC 180 New Window Dual Owners Suite 13 Window 6.6 0.390 NFRC 0.39 NFRC 180 New Window Dual Owners Suite 14 Wndow 6.6 0.390 NFRC 0.39 NFRC 180 New Window Dual Owners Suite 15 Winnow 6.6 0.390 NFRC 0.39 1 NFRC 180 New Window Dual Owners Suite 16 Window 57.2 0.390 NFRC 0.39 1 NFRC 180 New Window Dual Owners Suite (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Ri ht Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Buq Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 EnergyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2013-02-13T07:45:49 ID: Page 8 of 38 C] CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2113/2013 OPAQUE SURFACE DETAILS Surface Type Area V- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 636 0.730 None 0 180 New 4.4.7-A1 Great Dining Kitchen Slab 2,302 0.730 None 0 180 New 4.4.7-A1 Great Dining Kitchen Roof 503 0.026 R-38 0 20 New 4.2.1-A9 Guest 2 Wall 426 0.069 R-21 0 90 New 4.3.1-A6 Guest 2 Wall 396 0.069 R-21 90 90 New 4.3.1-A6 Guest 2 Wall 1021 0.069 R-21 180 90 New 4.3.1-A6 Guest 2 Wall 4681 0.069 R-21 270 90 New 4.3.1-A6 Guest 2 Slab 2281 0.730 None 0 180 New 4.4.7-A1 Guest 2 Slab 2751 0.730 None 0 180 New 4.4.7-A1 Guest 2 Roof 416 0.026 R-38 0 20 New 4.2.1-A9 Guest 1 Wall 320 0.069 R-21 0 90 New 4.3.1-A6 Guest 1 Wall 164 0.069 R-21 90 90 New 4.3.1-A6 Guest 1 will 356 0.069 R-21 180 90 New 4.3.1-A6 Guest 1 Wall 180 0.069 R-21 270 90 New 4.3.1-A6 Guest 1 Slab 296 0.730 None 0 180 New 4.4.7-A1 Guest 1 Slab 1201 0.730 None 0 180 New 4.4.7-A1 1 Guest 1 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 6.6 0.390 1 NFRC 0.39 NFRC 270 New Window Dual Owners Suite 18 Window 6.6 0.390 NFRC 0.39 NFRC 270 New Window Dual Owners Suite 19 Window 6.6 0.390 NFRC 0.39 NFRC 270 New Window Dual Owners Suite 20 Window 6.6 0.390 NFRC 0.39 NFRC 270 New Window Dual Owners Suite 21 Window 6.6 0.390 NFRC 0.39 NFRC 270 New Window Dual Owners Suite 22 Window 96.0 0.390 NFRC 0.39 NFRC 270 New Window Dual Owners Suite 23 Window 58.0 0.390 NFRC 0.39 NFRC 270 New Window Dual Owners Suite 24 Window 58.3 0.390 NFRC 0.39 NFRC 270 New Window Dual Owners Suite 25 Window 37.1 0.390 NFRC 0.39 NFRC 0 New Window Dual Great Dining Kitchen 26 Window 240.0 0.390 NFRC 0.39 NFRC 0 New Window Dual Great Dining Kitchen 27 Window 30.6 0.390 NFRC 0.39 NFRC 0 New Window Dual Great Dining Kitchen 28 Window 26.6 0.390 NFRC 0.39 NFRC 90 New Window Dual Great Dining Kitchen 29 Window 25.9 0.390 NFRC 0.39 NFRC 90 New Window Dual Great Dining Kitchen 30 Window 6.3 0.390 NFRC 0.39 NFRC 90 New Window Dual Great Dining Kitchen 31 Window 6.3 0.390 NFRC 0.39 NFRC 90 New Window Dual Great Dining Kitchen 32 Window 6.3 0.390 NFRC 0.39 NFRC 90 New Window Dual Great Dining Kitchen (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Ri ht in Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bua Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Buq Screen 0.76 31 Bug Screen I 0.76 32 IBug Screen 1 0.76 EnerqyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Page 9 of 38 • • 11 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1211312013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 1,128 0.026 R-38 0 20 New 4.2.1-A9 2nd Floor Wall 200 0.069 R-21 0 90 New 4.3.1-A6 2nd Floor Wall 120 0.069 R-21 45 90 New 4.3.1-A6 2nd Floor Wall 80 0.069 R-21 90 90 New 4.3.1-A6 2nd Floor Wall 171 0.069 R-21 270 90 New 4.3.1-A6 2nd Floor Wall 1201 0.069 R-21 270 90 New 4.3.1-A6 2nd Floor Wall 140 0.069 R-21 270 90 New 4.3.1-A6 2nd Floor Wall 120 0.069 R-21 270 90 New 4.3.1-A6 2nd Floor FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 117.0 0.390 NFRC 0.39 NFRC 135 New Window Dual Great Dining Kitchen 34 Window 63.0 0.390 NFRC 0.39 NFRC 180 New Window Dual Great Dining Kitchen 35 Window 240.0 0.390 NFRC 0.39 NFRC 180 New Window Dual Great Dining Kitchen 36 Window 43.2 0.390 NFRC 0.39 NFRC 270 New Window Dual Great Dining Kitchen 37 Window 6.3 0.390 NFRC 0.39 NFRC 270 New Window Dual Great Dining Kitchen 38 Window 6.3 0.390 NFRC 0.39 NFRC 270 New Window Dual Great Dining Kitchen 39 Window 6.3 0.390 NFRC 0.39 NFRC 270 New Window Dual Great Dining Kitchen 40 Window 18.0 0.390 NFRC 0.39 NFRC 0 New Window Dual Guest 2 41 Window 18.0 0.390 NFRC 0.39 NFRC 0 New Window Dual Guest 2 42 Window 18.0 0.390 NFRC 0.39 NFRC 0 New I Window Dual Guest 2 43 Window 6.0 0.390 NFRC 0.39 NFRC 0 New Window Dual Guest 2 44 Window 6.0 0.390 NFRC 0.39 NFRC 0 New Window Dual Guest 2 45 Window 6.0 0.390 NFRC 0.39 NFRC 0 New Window Dual Guest 2 46 Window 6.0 0.390 NFRC 0.39 NFRC 0 New Window Dual Guest 2 47 Window 42.0 0.390 NFRC 0.39 NFRC 180 New Window Dual Guest 2 48Window 76.5 0.390 NFRC 0.39 NFRC 0 New Window Dual Guest 1 (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Ri ht Fin Len I H t LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Buc Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 1 0.76 48 JBug Screen 0.76 Ene Pro 5.1 by EnerqySoft User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Page 10 of 38 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Sedona Homes Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1211312013 OPAQUE SURFACE DETAILS Surface U- Insulation Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status Joint Appendix 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 49 Window 4.0 0.390 NFRC 0.39 NFRC 90 New Window Dual Guest 1 50 Window 4.0 0.390 NFRC 0.39 NFRC 90 New Window Dual Guest 1 51 Window 4.0 0.390 NFRC 0.39 NFRC 90 New Window Dual Guest 1 52 Window 4.0 0.390 NFRC 0.39 NFRC 90 New Window Dual Guest 1 53 Window 40.0 0.390 NFRC 0.39 NFRC 180 New Window Dual Guest 1 54 Window 11.5 0.390 NFRC 0.39 NFRC 270 New Window Dual 2nd Floor 55 Window 17.5 0.390 NFRC 0.39 NFRC 270 New Window Dual 2nd Floor 56 Window 60.0 0.390 NFRC 0.39 NFRC 270 New Window Dual 2nd Floor (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove hanq Left Fin Ri ht Fin Len HM LExt RExt Dist Len Wit I Dist Len I H t 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 EnemyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2013-02-13707:45:49 ID: Pae 11 of 38 • • • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Sedona Homes Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 2113/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC 1 Owners Suite 1,492 17,904 HVAC 2 & 3 Great Dining Kitchen 2,938 41,132 HVAC 4 Guest 2 503 6,036 HVAC 5 Guest 1 416 4,992 HVAC 6 2nd Floor 1,128 13,536 Totals 6,477 0 0 0 HVAC SYSTEMS System Name Qty. Heatinq Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 2 & 3 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC 4 1 Split Heat Pump 8.00 HSPF SplitHeatPurnp 14.0 SEER Setback New HVAC 5 1 Split Heat Pume 8.00 HSPF Split Heat Pump 14.0 SEER Setback New HVAC 6 1 1 Split Heat Pump 8.00 HSPF Split Heat Pump 14.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 m New HVAC 2 & 3 Ducted Ducted Attic, Ceiling Ins, vented 4.2 0 New HVAC 4 Ducted Ducted Attic, Ceiling Ins, vented 4.2 d New HVAC 5 Ducted I Ducted I Attic, Ceiling Ins, vented 1 8.0 0 New HVAC 6 Ducted I Ducted JAttic, Ceiling Ins, vented 8.01 0 New WATER HEATING SYSTEMS S stem Name Oty. Type Distribution Rated Input (Btu h) Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White Corp. EF -1 2 JLargeGas All Pipes Ins 150,000 100 0.99 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft C 0 a System Name [Llenth Pipe Diameter Insul. Thick. D FHP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Pae 12 of 38 C. MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Sedona Homes Date 1 2/13/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(6)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. -* 150 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent LI -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. 'Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy -Commission. "§1 13(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of 113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heatin systems are equipped with thermostats that meet the setback requirements of Section 112 c . §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. '§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of • recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and E nation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §150(i)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(i)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro5.1 by EnergySoft User Number: 6712 Run Code: 2013-02-13T07:45:49 ID: Page 13 of 38 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Sedona Homes 2/13/2013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §150(m)10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. §150(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150(p). Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by 4150(k)2. 150(k)3: The watta a of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Liahting inte ral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 4150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or. 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. I EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Page 14 of 38 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Sedona Homes 1211312013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). ;.§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146.' §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling. units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 4119. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Page 15 of 38 1� HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Sedona Homes Date 2/13/2013 System Name HVAC 1 Floor Area 1,492 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 1,982 35,407 Return Vented Lighting 0 Return Air Ducts 2,420 Return Fan o Ventilation 0 0 Supply Fan 0 Supply Air Ducts 2,420 TOTAL SYSTEM LOAD 1 40,246 COIL HTG. Latent CFM 3,380 615 0 0 3,380 PEAK Heating System Sensible Output perSystem 89,000 26,465 Total Output Btuh 89,000 Output Btuh/s ft 59.7 1,433 Cooling System 0 Output perSystem 58,500 0 Total Output Btuh 58,500 0 Total Output ons 4.9 1,433 Total Output Btuh/s ft 39.2 Total Output s ft/Ton 306.1 29,331 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 40,558 Total Adjusted System Output 40,558 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 6,959 89,000 6,959 1 89,000 Aug 3 PM Jan 1 AM Airflow cfm/s ft 1.34 Airflow cfm/Ton 410.3 Outside Air°/, 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 71 OF 71 OF 113 OF 113 OF Heating Coil Supply Fan 2,000 cfm 112 o F ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air -4r 0 cfm 71 / 59 OF 4 w 1 71 /59°F 52/51 OF 52/51 OF ZI Cooling Coil Supply Fan 53 / 52 OF 2,000 cfm 51.8% ROOM in 70159 OF L I *. 1 13 EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2013-02-13T07:45:49 ID: Page 16 of 38 C. 1� HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ISedona Homes Date 2/13/2013 System Name HVAC,2 & 3 Floor Area 2,938 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 2,305 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 89,000 43,489 5,881 992 42,976 Total Output Btuh 178,000 0 Output Btuh/s K 60.6 2,972 2,326 Cooling System 0 0 Output per System 58,500 0 0 0 0 Total Output Btuh 117,000 0 2,972 1 49,433 5,881 0 Total Output ons 9.8 2,328 Total Output Btuh/s ft 39.8 Total Output s ft/Ton 301.3 47,631 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 4,000 Carrier 81,402 12,929 178,000 Airflow cfm/s ft 1.36 Airflow cfm/Ton 410.3 Outside Air % 0.0% Total Adjusted System Output 81,402 (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK r 12,929 178,000 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 71 OF 71 OF 113 OF 1130F Heating Coil Supply Fan 113 OF 4,000 cfm ROOM NX j 72 OF r COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF Outside Air 0 cfm 71/59°F I 71 159 OF 52 / 51 OF 52151 OF Supply Fan 52 / 51 °F Cooling Coil • 4,000 cfm. ... • 50.6% ROOM 70/59°F EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Page 17 of 38 I. a HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Sedona Homes Date 2/13/2013 System Name HVAC 4 Floor Area 503 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 497 10,312 Return Vented Lighting 0 Return Air Ducts 705 Return Fan o Ventilation o 0 Supply Fan 0 Supply,Air Ducts 705 TOTAL SYSTEM LOAD 11,721 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Outputper System 18,000 1,670. 714 12,167 Total Output Btuh 18,000 Output Btuh/s ft 35.8 510 Cooling System 0 Output perSystem 18,000 0 0 0 Total Output Btuh 18,000 1,670 0 Total Output ons 1.5 510 Total Output Btuh/s ft 35.8 Total Output s ft/Ton 335.3 13,186 Air System CFM perSystem 600 HVAC EQUIPMENT SELECTION Airflow (cfm) 600 Mitsubishi 13,871 536 11,242 Alrflow cfm/s ft 1.19 Total Adjusted System Output 1 13,871 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 536 1 11,242 Aug 3 PM Jan 1 AM Airflow cfm/Ton 400.0 Outside Air % 0.0 % ;Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm Ar 71 OF 71 OF 89 OF 89 OF UMMA Heating Coil Supply Fan 88 OF 600 cfm L ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF Outside Air 0 cfrn 71 / 58 °F 71 / 58 OF 49 / 48 OF 49148 OF Cooling Coil Supply Fan 50 / 49 OF ` 600 cfm..............._.................._............. . 48.2% ROOM 70158 OF EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2013-02-13707:45:49 0: Page 18 of 38 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Sedona Homes Date 2/13/2013 System Name HVAC 5 Floor Area 416 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads aa5 9,667 Return Vented Lighting 0 Return Air Ducts 456 Return Fan o Ventilation F o 0 'Supply Fan 0 Supply Air Ducts 456 TOTAL SYSTEM LOAD 1 10,578 PEAK COIL HTG. PEAK Heatinq System, Latent CFM Sensible Output perSystem 18,000 1 ;lql 610 10,765 Total Output Btuh 18,000 Output Btuh/s ft 43.3 326 Cooling System 0 Output perSystem 18,000 0 0 0 Total Output Btuh 18,000 1,519 0 Total Output ons 1.5 326 Total Output Stuh/s ft 43.3 Total Output s ft/Ton 277.3 11,417 Air System CFM perSystem 600 HVAC EQUIPMENT SELECTION Airflow cfm 600 Mitsubishi 13,955 Total Adjusted System Output 13,955 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 349 11,242 349 11,242 Aug 3 PM Jan.1 AM Airflow cfm/s ft 1.44 Airflow cfm/Ton 400.0 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 71 OF 71 OF 89 OF 89 °F I Heating Coil Supply Fan 89 OF 600 cfm ROOM _ 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak • 112 / 78 °F Outside Air 0 cfm 71 / 58 OF 71 / 58 OF 49 / 48 OF 49148 OF Cooling Coil Supply Fan 50148 OF 600 cfm 46.9% ROOM 70/ 58 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Page 19 of 38 I I a HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Sedona Homes Date 2/13/2013 System Name HVAC 6 Floor Area 1,128 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 704 Return Vented Lighting Return Air Ducts Return Fan Ventilation F 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD_ COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 18,000 13,691 2,7511 560 9,935 Total Output Btuh 18,000 0 Output Btuh/s ft 16.0 645 301 Cooling System 0 0 Output per System 18,000 0 0 0 0 Total Output Btuh 18,000 0 645 1 14,981 2,751 0 Total Output ons 1.5 301 Total Output Btuh/s ft 16.0 Total Output s ft/Ton 752.0 10,536 Air System CFMper System 600 HVAC EQUIPMENT SELECTION Airflow cfm 600 Mitsubishi 12,965 Total Adjusted System Output 12,965 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1,735 11;242" 1,735 1 11,242 Aug 3 PM Jan 1 AM Airflow cfm/s ft 0.53 Airflow cfm/Ton 400.0 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF " 72 OF 89 OF, 89 OF Heating Coil Supply Fan 89 OF 600 cfm _ ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 71!60°F 71 /60°F 51 /50°F 51 /50°F o _ Cooling Coil Supply Fan 52 / 50 OF 600 cfm.........._...._._ ............. ....... .._._...... 53.3% ROOM 70/59°F EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-13707:45:49 /D: Page 20 of 38 C] • • rOOM LOAD SUMMARY ject NameDate dona Homes 2/13/2013 System Name Floor Area HVAC 1 1,492 ROOM LOAD SUMMARY Owners Suite I Owners Suite ROOM COOLING PEAK COIL COOLING PEAK I COIL Mult. CFM I Sensible I Latent CFM I Sensible I Latent I CFM 1 1 1,9821 35,4071 3,3801 1,9821 35,4071 3,3801 61 PAGE TOTAL TOTAL• PEAK nsible 26,465 1,982 35,407 3,380 615 26,465 1, 982 35, 407 3, 380 615 26,46 5 Total includes ventilation load for zonal systems. EnergyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Pa a 21 of 38 • ROOM LOAD SUMMARY Project Name Date Sedona Homes 2/13/2013 System Name Floor Area HVAC 2 & 3 2,938 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone NameRoom Name Mult. CFM I Sensible I Latent CFM I Sensible I Latent CFM I Sensible Great Dining Kitchen Great Dining Kitchen 1 1 1 2,3051 43,4891 5,881 2,3051 43,4891 5,881 992 42,976 • - Total includes ventilation load for zonal EnemyPro 5.1 by EnemySoft User N. PAGE TOTAL TOTAL' 2013-02-13T07:4 2,305 43,4891 5,8811 992 42',976 2,305 43,489 5,881 992 42,976 ROOM LOAD SUMMARY Project Name Date Sedona Homes 2/13/2013 System Name Floor Area HVAC 4 503 ROOM LOAD SUMMARY. ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible. Latent CFM Sensible Guest Guest 1 497 10,312 1,670 497 10,312 1,670 714 12,167 PAGE TOTAL TOTAL' 497 10,312. 1,670 714 12,167 497 10,312 1,670 714 12,167 Total includes ventilation load for zonal systems. EnemvPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-13707:45:49 0: Pa a 23 of 38 • 0 • ROOM LOAD SUMMARY Project Name Date Sedona Homes 2/13/2013 System Name Floor Area HVAC 5 416 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM I Sensible I Latent CFM I Sensible Guest 1 I Guest 1 1 1 1 4451 9,6671 1,519 4451 9,6671 1,519 610 10,765 PAGE TOTAL TOTAL' 445 9,667 1,519 610 10,765 445 9,667 1,519 610 10,765 Total includes ventilation load for zonal systems. EnemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Page 24 of 38 • 0 ROOM LOAD SUMMARY Project Name Date Sedona Homes 2/13/2013 System Name Floor Area HVAC 6 1,128 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible Latent CFM Sensible Latent I CFM I Sensible 2nd Floor 2nd Floor 1 7041 13,691 2,751 7041 13,6911 Z 7511 5601 9,935 PAGE TOTAL TOTAL' 704 13,6911 2,7511 560 9,935 704 13,6911 2,7511 560 9, 935 Total includes ventilation load for zonal systems. EnergyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2013-02-13T07:45:49 ID: Page 25 of 38 • ROOM HEATING PEAK LOADS Project Name Sedona Homes Date 2/13/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Owners Suite Floor Area 1,492.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area R-38 Roof(R.38.2x14.16)C 1,492.0 R-21 Wall (W..21.2x6.16) 1,419.6 Window Dual 560.4 Slab -On -Grade perm = 145.0 Items shown with an asterisk (') denote conduction through an interior surface Infiltration:[ 1.00 )( 1.064 X 1,492 X Schedule Air Sensible Area Fraction U -Value AT °F X 46 X 46 Btu/hr = 1,784 = 4,506 = 10,054 = 4,869 — - = - = = - = = = = = - - = = = = = = = = - _ = - = • 21.213 46 = 5,252 X 0.0260 X X X X X X 0.0690 0.3900 X X X X X 46 0.7300 46 X X X X X X X X X X X X X X X X X X X X X X X X X X X X. X X X X X X X X X X X X X X X X X X X Page Total /60] X AT X. to another room 12.00 X 0.360 Ceiling Height ACH TOTAL HOURLY HEAT LOSS FOR ROOM 26 465 EnergyPro 5.1 by EnergySoft User Number.- 6712 RunCode: 2013-02-13707:45:49 ID: Page 26 of 38 • • • ROOM HEATING PEAK LOADS Project Name Sedona Homes Date 2/13/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Dining Kitchen Floor Area2,938.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value AT OF Btu/hr = 2,784 = 7,468 = 15,450 = 552 = 6,380 = = = = = = = = = = = = = = = = = = = = = = = 32,634 46 = 10,342 R-38 Roof(R.38.2x14.16)C 2,328.0 X 0.0260 X 46 R-21 Wall (W.21.2x6.16) . 2,352.8 X X X X 0.0690 X X X X 46 Window Dual 861.2 0.3900 46 Wood Door 24.0 0.5000 46 Slab -On -Grade perim = 190.0 0.7300 46 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X Schedule Air Sensible Fraction through an interior surface 1.064 X 2,938 X Area to another room 14.00 X 0.308 Ceiling Height ACH Page Total /60] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 42,976 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-13T07:45:49 ID: Page 27 of 38 • • • ROOM HEATING PEAK LOADS Project Name Date Sedona Homes 2/13/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 2 Time of Peak Jan 1 AM Floor Area 503.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF Conduction Area U -Value AT OF Btu/hr R-38 Roof(R.38.2x14.16)C 503.0 X 0.0260 X 46 = 602 R-21 Wall (W.21.2x6.16) 1,392.0 X 0.0690 X 46 = 4,418 Window Dual 120.0 X 0.3900 X 46 = 2,153 Slab -On -Grade perim = 96.0 )( 0.7300 X 46 = 3,224 X X = X X = X X = X X = X X = X X = X X X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 10,396 Infiltration:[ 1.00 X 1.064 X 503 X 12.00 X 0.360 /60] X 46 = 1,771 Schedule Air Sensible Area Ceiling Height ACH AT Fraction - TOTAL HOURLY HEAT LOSS FOR ROOM 12,167 EnergyPro 5.1 by EnergySoft User Number.- 6712 RunCode: 2013-02-13707:45:49 ID: Page 28 of 38 • • ROOM HEATING PEAK LOADS Project Name Sedona Homes Date 2/13/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 1 Floor Area 416.0 ft' Indoor Dry Bulb Temperature 72 OF, Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value AT °F Btu/hr = 498 = 3,236 = 2,377 = 3,190 = = = = = = = = = = = = = = = = = = = = = = = = = = 9,301 46 = 1,464 R-38 Roof(R.38.2x14.16)C 416.0 X 0.0260 X 46 R-21 Wall (W.21.2x6.16) 1,019.5 X X X X X 0.0690 X X X X X 46 Window Dual 132.5 0.3900 46 Slab -On -Grade Perim = 95.0 0.7300 46 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to another room 12.00 X 0.360 Ceiling Height ACH Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 416 X Area Page Total /60] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 10,765 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Page 29 of 38 • • • i ROOM HEATING PEAK LOADS' Project Name Sedona Homes Date 2/13/2013 ROOM INFORMATION DESIGNCONDITIONS Room Name 2nd Floor Floor Area 1,128.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature ' 26 OF Conduction Area U -Value - R-38 Roof(R.38.2x14.16)C 1,128.0 X 0.0260 R-21 Wall (W21.2x6.16) 951.0 X 0.0690 Window Dual 89.0 )( 0.3900 X X X X X X X X X X' X X X X X X X X X X - X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to another room Infiltration:[ 1.00 X .1.064 X 1,128 X 12:00 X 0.360 Schedule Air Sensible Area Ceiling Height ACH Fraction AT OF X 46 = = = = = = = = _ - = = = = = = = = - = = = - = - = = = = = = 46 Btu/hr 1,349 X X 46 3,018 46 1,597 X X X X X X' X X X X X X X X X X X X X X X X X X X X X X Page Total /60] X AT 5,964 = 3,971 TOTAL HOURLY HEAT LOSS FOR ROOM 9,935 EnergyPro 5.1 by Energ Soft User Number.' 6712 RunCode: 2013-02-13707:45:49 ID: Page 30 of 38 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Sedona Homes 1 2113/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Owners Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,492.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF ODaOue Surfaces R-38 Roof(R.38.2x14.16)C R-21 Wall (1..21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation (N) (E) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = 1,492.0 0.0260 56.0 336.0 0.0690 23.0 541.7 0.0690 33.0 267.2 0.0690 26.0 274.7 0.0690 33.0 16.6 45.4 0.0 22.3 6.6 45.4 0.0 22.3 6.6 45.4 = 0.0 22.3 + 6.6 + 6.6 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Coolinq Load Temperature Difference (CLTD) Fa_nPstratinn Window Window Window Window Window Window Window Window Window Ariantatinn (E) (E) (E) (E) (E) (E) (E) (E) (E) 2,172 533 1,233 479 625 1 5,0441 Shaded Area X X X X X X X X X GLF Unshaded Area + 56.1 + 33.6 + 91.6 + 4.0 X X X X X X X X X GLF 45.4 = 0.0 22.3 0.0 22.3 45.4 = = = = = 0.0 22.3 45.4 0.0 22.3 45.4 0.0 22.3 + + + 16.6 45.4 0.0 22.3 6.6 45.4 0.0 22.3 6.6 45.4 = 0.0 22.3 + 6.6 + 6.6 45.4 = = 0.0 22.3 45.4 Page Total Btu/hr Z548 1,526 4,161 182 300 300 300 300 300 9,917 Internal Gain Btu/hr Occu pants 4.0 Occupants X 230 Btuh/occ. •920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.27 X 81.64 X 42 = 4,618 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 35,407 Latent Gain Btu/hr 800 Occupants 4.0 Occupants X 200 Btuh/occ. = Infiltration: 4.771 X 1.27 X 81.64 X 0.00523 = 2,580 Air Sensible CFM ELA DW NT HEAT GAIN FOR ROOM • 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Sedona Homes 1 2/13/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Owners Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,492.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) FanPctratinn Window Window Window Window Window Window Window Window Window Orientation (S) Shaded Area GLF X 22.3 X 22.3 X 22.3 X 22.3 X 22.3 X 22.3 X 22.3 X 22.3 X1 22.3 + + + + + + + + + Unshaded Area GLF X 22.4 X 22.4 X 22.4 X 22.4 X 22.4 X 22.4 X 22.4 X 45.4 X1 45.4 Page Total = = = = = = = = = 0.0 6.6 0.0 6.6 0.0 6.6 0.0 6.6 0.0 6.6 0.0 6.6 0.0 57.2 0.0 6.6 0.0 6.6 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Btu/hr 01 148 148 148 148 148 148 1,279 300 300 2, 764 Internal Gain tstumr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 16001 Btu = 1,600 Infiltration: 1.064 X 1.27 X 81.64 X 42 = 4,618 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 35,407 Latent Gain Btu/hr Occu ants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 81.64 X 0.00523 = 2,580 Air Sensible CFM ELA AW AT GAIN FOR ROOM L-] 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Sedona Homes 1 2/13/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Owners Suite Outdoor Dry Bulb Temperature 112 OF Floor Area 1,492.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Tem erature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction_through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window W 0.0 X 22.3 + 6.6 X 45.4 = 300 Window 0.0 X 22.3 + 6.6 X 45.4 = 300 Window 0.0 X 22.3 + 6.6 X 45.4 = 300 Window (IM 0.0 X 22.3 + 96.0 X 45.4 = 4,361 Window W 0.0 X 22.3 + 58.0 X 45.4 = 2,635 Window 0.0 X 22.3 + 58.3 X 45.4 = 2,648 X + X = X + X = X +1 X = Page Total 10,544 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 x 1.27 X 81.64 X 42 = 4,618 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 35,407 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 81.64 X 0.00523],= 2,580 Air Sensible CFM ELA Aw. TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,380 EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Page 33 of 38 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Sedona Homes 1 2113/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Dining Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 2,938.0ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature, 70 OF Outdoor Daily Range: 34 OF, Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16)C R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Wood Door R-21 Wall (W.21.2x6.16) R-21 Wall (1..21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) (N) X X X X X X X X X 2,328.0 X X X X X X X X X 0.0260 X X X X X X X X X 56.0 = = = = = = = = = (N) (E) (E) 448.3 0.0690 23.0 664.6 0.0690 33.0 24.0 0.5000 33.0 (SE) (S) 143.0 0.0690 31.0 453.0 0.0690 26.0 (SIM (1M (NIM 286.0 0.0690 31.0 201.9 0.0690 33.0 156.0 .06901 1 30.2 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Window Window Window Window Window Window Window Window Window (N) (N) (N) (E) (E) (E) (E) (E) (SE) 0.0 X X X X X X X X X 22.3 + + + + + + + + + 37.1 X X X X X X X X X 22.3 = = = = = = = = = 0.0 0.0 0.0 22.3 240.0 22.3 22.3 30.6 22.3 22.3 26.6 45.4 0.0 0.0 22.3 25.9 45.4 22.3 6.3 45.4 0.0 22.3 6.3 45.4 0.0 0.0 22.3 6.3 45.4 22.3 117.0 31.2 Page Total 711 1,513 396 306 813 612 460 325 8,526 Btu/hr 826 682 1,208 1,177 286 286 286 3, 656 13, 753 . Occupants v 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 9.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.27 X . 160.77 X 42 = 9,094 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 43,489 Latent Gain Btu/hr Occupants 4.0 .Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 160.77 X 0.00523 = 5,081 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Sedona Homes 1 2/13/2013 ROOM INFORMATION DESIGN CONDITIONS ' Room Name Great Dining Kitchen Outdoor Dry Bulb Temperature 112 OF Floor Area 2,938.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ran e:� 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X X X = X X = X X X X = X X = X X = X X = X X = Page Total '0 Items shown with an asterisk (') denote conduction through an interior surface to anottier'room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation . Area GLF Area GLF Btu/hr Window (S) 0.0 X ._ 22.3 + 63.0 X 22.4 = 1,409 Window (S) " 0.0 X 22.3 + 240.0 X 22.4 = 5,367 Window W 0.0 X 22.3 + 43.2 X 45.4 = 1,962 Window (lM 0.0 X 22.3 + 6.3 X 45.4 = 286 Window (Vt/) 0.0 X 22.3 ;+ 6.3 X 45.4 = 286 Window (14 0.0 X 22.3 + 6.3 X 45.4 = 286 X + X = X + X = X + X = Page Total 9,597 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration:. 1.064 X 1.27 X 160.77 X- 42 = 9,094 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 43,489 Latent Gain Btu/hr Occupants -7�14.0 .Occupants X - 200 Btuh/occ. _ 800 Infiltration: 4,771 X 1.27 X 160.77 X 0.00523 = 5,081 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 5,881 EnerovPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-02-13707:45:49. ID: Page 35 of 38 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Sedona Homes 2113/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 503.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16)C (N) 503.0 X 0.0260 X 56.0 = 732 R-21 Wall (W.21.2x6.16) (N) 426.0 X 0.0690 X 23.0 = 676 R-21 Wall (W.21.2x6.16) (E) 396.0 X 0.0690 X 33.0 = 902 R-21 Wall (W.21.2x6.16) (S) 102.0 X 0.0690 X 26.0 = 183 R-21 Wall (W.21.2x6.16) (W) 468.0 X 0.0690 X 33.0 = 1,066 X X = X X = X X = X X I= Page Total 3,559 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF - Area GLF Btu/hr Window (N) 0.0 X 22.3 + 18.0 X 22.3 = 401 Window (N) 0.0 X 22.3 + 18.0 X 22.3 = 401 Window (N) 0.0 X 22.3 + 18.0 X 22.3 = 401 Window (N) 0.0 X 22.3 + 6.0 X 22.3 = 134 Window (N) 0.01 X 22.3 + 6.0 X 22.3 = 134 Window (N) 0.0 X 22.3 + 6.0 X 22.3 = 134 Window (N) 0.0 X 22.3 + 6.0 X 22.3 = 134 Window (S) 0.0 X 22.3 + 42.0 X 22.4 = 939 X + X = Page Total 2,676 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.27 X 27.52 X 42 = 1,557 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,312 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 27.52 X 0.00523 = 870 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,670 Ene Pro 5.1 bv EnerovSoft User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Page 36 of 38 0 0 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Sedona Homes 2/13/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 1 Outdoor Dry Bulb Temperature 112 OF Floor Area 416.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature, 70 OFI Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16)C (N) 416.0 X 0.0260 X 56.0 = 606 R-21 Wall (W.21.2x6.16) (N) 319.5 X 0.0690 X 23.0 = 507 R-21 Wall (W.21.2x6.16) (E) 164.0 X 0.0690 X 33.0 = 373 R-21 Wall (W.21.2x6.16) (S) 356.0 X 0.0690 X 26.0 = 639 R-21 Wall (W.21.2x6.16) (W) 180.0 X 0.0690 X 33.0 = 410 X X = X X = X X = X -J X = Page Total 2,535 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (N) 0.0 X 22.3 + 76.5 X 22.3 = 1,704 Window (E) 0.0 X 22.3 + 4.0 X 45.4 = 182 Window (E) 0.0 X 22.3 + 4.0 X 45:4 = 182 Window (E) 0.0 X 22.3 + 4.0 X 45.4 = 182 Window (E) 0.0 X 22.3 + 4.0 X 45.4 = 182 Window (S) 0.01 X 22.3 + 40.0 X 22.4 = 895 X + X = X + X = X 1+1 ix = Page Total 3,325 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. 920 Equipment 1.0 Dwelling Unit X 1,6001 Btu = 1,600 Infiltration: 1.064 X 1.27 X 22.76 X 42 = 1,288 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 9,667 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,77a X 1.27 X 22.76 X 0.00523 = 719 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,519 EnemvPro 5.1 by EnerqvSoft User Number: 6712 RunCode: 2013-02-13707:45:49 /D: Pa a 37 of 38 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Sedona Homes - 2113/2013 ROOM INFORMATION DESIGN CONDITIONS _ Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 1,128.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x14.16)C (N) 1,128.0 X 0.0260 X 56.0 = 1,642 R-21 Wall (W.21.2x6.16) (N) 200.0 X 0.0690 X 23.0 = 317 R-21 Wall (W.21.2x6.16) (NE) 120.0 X 0.0690 X 29.0 = 240 R-21 Wall (W.21.2x6.16) (E) 80.0 X 0.0690 X 33.0 = 182 R-21 Wall (W.21.2x6.16) (VV) 551.01 X 0.0690 X 33.0 = 1,255 X X =. X X = X X = X X = Page Total 3,637 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (W) 0.0 X 22.3 + 11.5 X 45.4 = 522 Window (W) 0.0 X 22.3 + 17.5 X 45.4 = 795 Window (W) 0.0 X 22.3 + 60.0 X 45.4 = 2, 726 X + X = X + X = X + X = X + X = X + X _ X +1 X = Page Total 4,043 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 1.27 X 61.72 X 42 = 3,491 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,691 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 1.27 X 61.72 X 0.00523 = 1,951 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,751 EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-02-13707:45:49 ID: Page 38 of 38 Sladden Engineering 45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 ' 800 E. Florida Avenue, Hemet, CA 92543 (951) 766-8777 Fax (951) 766-8778 February 8, 2013 Project No. 544-12175 13-02-056 Sedona Homes 40101 Monterey Avenue, Suite B1-214. RECrI.— HVED Rancho Mirage, California 92270 lq Subject: Foundation and Precise Grading Plan Review " FEB 19 '013 Project: Proposed Custom Residence COMMUNITY DEVELOPMENT OIC' 0 .� t A 53615 Via Strada �. The Hideaway La Quinta, California , Ref: Geotechnical -Update prepared by Sladden Engineering dated November 6, 2012; Project No. 544-12175, Report No. 12-11-284 As requested, we have reviewed the Foundation Plans and Details prepared by Patel Burica & Associates, Inc. and the Precise Grading Plans prepared by Feiro Engineering, Inc. for the proposed custom residence to be located at 53615 Via Strada within the Hideaway development in the City of. La Quinta, California. Based on our review, it is our opinion that the recommendations provided in the above referenced Geotechnical Update report and previous geotechnical reports have been properly incorporated in these plans. If you have questions regarding this memo or, the referenced report, please contact the undersigned. \ Respectfully submitted, SLADDEN ENGINEERING Fy Brett L. Anderson gNDERSON Principal Engineer — No. 045389 m Exp.9/3011< _ CIVIL Letter/gvm * ENGINEERING Copies: 4/ Sedona Homes 1.00X Sladden Engineering 45090 Golf Center Parkway, Suite F, Indio, CA 92201 (760) 863-0713 Fax (760) 863-0847 6782 Stanton Avenue, Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 800 E. Florida Avenue, Hemet, CA 92543 (951) 766-8777 Fax (951) 766-8778 November 6, 2012 Project No. 544-12175 12-11-284 Sedona Homes 40101 Monterey Avenue, #131-214 Rancho Mirage, California 92260, j Project: Proposed Custom Residence 53615 Via Strada The Hideaway La Quinta, California Subject: Geotechnical Update Ref: Geotechnical Engineering Report prepared by Earth Systems Southwest (ESSW) dated September 22, 2000; File No. 07117-10, Report No: 00-09-772 -Report of Testing and Observation During Rough Grading prepared by ESS dated August 28, 2002; File No. 07117-11, Report No. 01-07-718 Report of Testing and Observation. During Rough Grading prepared by Sladden Engineering dated. October 12, 2003; Project No. 544-2199 Report No. 03-10-647 +- As requested, we have reviewed the :above referenced geotechnical reports as they relate to the design and construction of the proposed custom residence. The project site is located at 53615 Via Strada within the Hideaway development in the City" of La Quinta, California. It is our understanding that the proposed residence will be a relatively lightweight wood-frame structure supported by conventional shallow spread footings and concrete slabs on grade. The subject lot was previously graded during the rough grading of the Hideaway project site and was subsequently regraded. The rough grading included over-excavation of the native surface soil along with the placement of engineered fill soil to construct the building pads. The regrading included processing the surface soil along with minor cuts and fills to construct the individual building pads to the current configurations. Some additional over-excavation was performed in areas where the building envelopes were reconfigured. The most recent site grading is summarized in the referenced Report of Testing and Observations During Rough Grading prepared by Sladden Engineering along with the compaction test results. DEC 2 7 2012 By .......... _...... ------------.._.._ _ _ ----- I i L..................... ._.._..__.._._._.__..__:__.._.........__... _....._____-........ ..... _... ................._ November 6, 2012, -2- Project No. 544-12175 12-11-284, Because the lot has been previously_ rough graded, the remedial grading required at this ,time should be minimal provided that the building falls within the previously assumed Luilding envelopes. The building area should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted to a minimum of 90 percent relative compaction is attained prior to fill placement. Any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. The allowable bearing pressures recommended in the referenced grading report prepared by Sladden Engineering remain applicable. Conventional shallow spread footings should be bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent grade. ` Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf for each additional 1 foot of width and 300 psf'for each additional 6 inches of depth may be utilized if -desired. The maximum allowable bearing pressure should be 3000 psf. The recommended allowable bearing pressures may be increased by one-third for wind and seismic loading. Lateral forces may be resisted by friction along the base of the foundations and passive resistance along the sides of the footings. A friction coefficient of 0.50 times the normal dead load forces is recommended for use in design. Passive resistance may be estimated using an equivalent fluid weight of 300 pcf. If used in combination with the passive resistance, the frictional resistance should be reduced by one third to 0.33 times the normal dead load forces. The bearing soil is non -expansive and falls within the "very low" expansion category in accordance with 2010 California Building Code (CBC) classification criteria. Slab thickness and reinforcement should be determined by the structural engineer, we recommend a minimum floor slab thickness of 4.0 inches. All slab reinforcement should be supported on concrete chairs to ensure that reinforcement is placed at slab mid -height. Slabs with moisture sensitive surfaces should be underlain with a moisture vapor retarder consisting of a polyvinyl chloride membrane such as 10 -mil Visqueen, or equivalent. All laps within the membrane should be sealed and at least 2 inches of clean sand should be placed over the membrane to promote uniform curing of the concrete. To reduce the potential for punctures, the membrane should be placed on a pad surface that has been graded smooth without any sharp protrusions. If a smooth surface can not be achieved by grading, consideration should be given to placing a 1 -inch thick leveling course of sand across, the pad surface prior to placement of the membrane. Based on our field observations and understanding of local geologic conditions, the soil profile type judged applicable to this site is SD, generally described as stiff soil. The following presents additional coefficients and factors relevant to seismic mitigation for new construction based upon the 2010 California Building Code (CBC). Sladden Engineering November 6, 2012 -3- Project No. 544-12175 12-11-284 The seismic design category for a structure may be determined in accordance with Section,.1613 of the 2010 CBC or ASCE7. According to the 2010 CBC, Site Class D may be used to estimate design seismic loading for the proposed structures. The 2010 CBC Seismic Design Parameters are summarized below. Occupancy Category (Table 1604.5):11 Site Class (Table 1613.5.2): D Ss (Figure 1613.5.1):1.508 Si (Figure 1613.5.1): 0.608 Fa (Table 1613.5.3(1)): IA Fv (Table 1613.5.3(2)):1.5 Sms (Equation 16-36 (Fa X Ss}): 1.508 Sml (Equation 16-37 (Fv X Si}): 0.908 SDS (Equation 16-38 (2/3 X Sms}): 1.008 SDI (Equation 16-39 12/3 X Smt}): 0.608 Seismic Design Category: D In addition, we have sampled the surface soil on the subject lot to determine the soluble sulfate content as it relates to selecting appropriate concrete mix designs. Testing indicates that the site soil is considered non-corrosive with respect to concrete. The testing indicated soluble sulfate content of 20 ppm (0.002 percent) that corresponds with the "negligible" exposure category in accordance with ACI 318-08, Table 3. In accordance with Table 3, special sulfate related concrete mix designs should not be required. If you have .questions regarding this .letter or the referenced reports, please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERING BRETT L. F ANDERSON Brett L. Anderson No. C65389 Principal Engineer - 9130/14 ENGINEERING SER/gvm Copies:' 4/Sedona Homes Sladden Engineering _..... _ ........... __......:............. ... ... _ Sladden Engineering 6782 Stanton Ave., Suite A, Buena Park, CA 90621 (714) 523-0952 Fax (714) 523-1369 �. s 45090 Golf Center Pkwy, Suite F, Indio, CA 92201 (760)863-071.1 Fax (760) 863-0847 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 Fax (951) 845-8863 Date: November 8, 2012 ' Account No.: 544-12.175 Customer: Sedona Homes Location: The Hideaway, 53615 Via.Strada, La Quinta 4 ' Analytical Report Sulfate Series Soluble Sulfates Soluble Chloride per CA 417 per CA 422 PPM PPM 20 150 • Sulfate 544-12175 11 0812.doc ...._.._.................. --.... -----_.............. _.__...__..._...._.. _-- TABLE 19-A-2—REQUIREMENTS-FOR SPECIAL EXPOSURE CONDMONS .. MINIMUM.Ic, • MAXIMUM NOR MAL-WEIGHTAND - '• WATER-CEMENTITIOUS .'LIGHTWEIGHT' - i 'MATERIALS:RAiIO,'BY. ; AGGREGATECONCRETE, . EXPOSURE CONDITION -WEIGHTS NORMAL-WEIGHT' • '.PSI' - Concrete intcndcd'lo have low pettrieability when AGGREGATE CONCRETE • x 0.00609 for MPa exposed to waier - Concrete, exposed to'freezing and thawing in a moist O.SO 4,000 condition or to deicing chemicals For corrosion protection for reinforced concrete 0.45 4,500 exposed to chlorides from deicing chemicals, salts or brackish hater, or.spray' from these sources - 040 5,000 TABLE 19-A-3—'REQUIREMENTS FOR CONCRETE EXPOSED TO SULFAT&CONTAINING'SOLUTIONS - - ,.- NORMAL-WEIGHT LIGHTWEIGHT.AGGREGATE - - AGGREGATE CONCRETE 'Ma.x[mum WATER- Water- I' .Normal- W401 ' ' SOLUBLE SULFATE _ Cen a tlifous PAaterials,Retla;by and. «.Ughtwelght - SULFATE (sot) IN SOIL, PERCNTAGE BY SULFATE (SOS) IN g Hormal-WeIgtit Concrerte,pap ' • EXPOSURE WEIGHT WA iER, 4) PP CEMENT, TYPE. Aggrogete Concrete' x 0.00689 for MPa , ' Negligible 0:00-0.10 0-150 — Moderatc2 0.10-0.20 150-1.500 II, IP(MS), IS _ 0.50 — WS) I 4,000 Sever 0.20-2.00' 1.500-10,000 V 0.45 Very severe Ov- 2.00 Ovcr 10,000 V plus 4,500 pozzolan3 0.45 4,500 IA lower water-ccmcntitious materials ratio.or higher strength may be required for low Permeability or for protection against corrosion of embedded itcrns'ocfTeezing,and thawing ' ZScawatcr-(Cable 19=A-2)- 3Pozzolan that has been determined by test or service record to improve sulfat taming Type V cement. e resistance when used in concrete con- 2-254 �. y