Loading...
04-3722 (SFD)J 2004 ix -4Tb'M UESEIMPIC01. LA QUINTA, CALIFORNIA 92253 Application Number 'Property Address . . . APN: Application description Property. Zoning . . . . Application valuation . BUILDING PERMIT BUILDING & SAFETY DEPARTMENT (760).777-7012 FAX (760) 777-7011 INSPECTION REQUESTS (760) 777-7153. . . ./ 04-00003722 Date 6/17/04 . . . 5343-9—VIA STRADA 772-540-034- - - :DWELLING - SINGLE FAMILY DETACHED i LOW DENSITY RESIDENTIAL _ 415159 Owner Contractor ------------------------ WOODARD DEVEOPMENT ------------------------ A & M CONSTRUCTION 80-880 VISTA BONITA TRAIL P.O. BOX 366 LA QUINTA CA 92553 LA QUINTA CA 92253 (760) 564-4832 WCC: STATE FUND WC: 0460009232 01/01/05 -CSLB: 746198 02/28/06 ". CCC: B -C10 ------ Structure Information NEW 4779 SQ. FT. SFD ----- Construction Type . . . . . TYPE V - NON RATED 'Occupancy Type . . . . . . DWELLG/LODGING/CONG <=10 Flood Zone . . . . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC # BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG 867.00 PATIO SQ FTG 904.00 NUMBER OF UNITS 1.00 FIRST FLOOR SQ FTG 4779.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . ''- Permi,t Fee . . . . 1595.00 Plan Check Fee 286.75 Issue Date . . . . Valuation . . . . 372284 Qty Unit Charge Per Extension BASE FEE 639.50 273.00 3.5000 THOU BLDG 100,001-500,000 955.50 ---------------------------------------------------------------------------- Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee . . . . 214.61 Plan Check Fee 53.65 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension P.O. Box 1504• ����� t1i . ,r,y VOICE (760) 777-7012 78-495 CALLE TAMPIG ;� FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 tl INSPECTIONS (760) 777-7153 BUILDING &SAFETY DEPARTIv1ENT ioi Application Number: f/ — �•li'' Applicant' Date: �- 9- Z)A � PP ^���� � jtect or Engineer BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I here y affiangnder penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals �L�s-Code, and my Lice s in (ull force and effect. No-77-h- ,r� e_Class. _N ( /" Cicenset ( V =: :3`6 - - OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant fora permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Mya2dcers' QQCpensafiQnlasurance carrier and Dolievnumber are: _ ..._ I certify that, in the perfonnancecof4he-work4or-which-this=permitis issDed, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Lis WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void 1fiyork is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is co I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon ove-menfiWd property for inspection purposes. Signature (Applicant or i Page 2 Application Number . . . . . 04-00003722 Date 6/17/04 Qty Unit Charge Per Extension BASE FEE 15.00 4779.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 167.27 867.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 17.34 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 ---------------------------------------------------------------------------- Permit . . . . . . GRADING PERMIT Additional desc Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL Additional desc Permit Fee . . . . 126.00 Plan Check Fee 31.50 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36.00 4.00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 5.00 6.5000 EA MECH VENT FAN 32.50 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING Additional desc Permit Fee . . . . 233.25 Plan Check Fee 58.31 Issue Date . . . . Valuation . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 22.00 6.0000 EA PLB FIXTURE 132.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 6.0000 EA PLB ROOF DRAIN 12.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB-WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 4.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 12.00 7.00 .7500 EA PLB GAS PIPE >=5 5.25 •� i Application Number . . . . . 04-00003722 Page 3 Date 6/17/04 Qty Unit Charge Per Extension 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 4779 SQ. FT. SFD. THIS PERMIT DOES NOT INCLUDE POOL & SPA , BLOCK WALLS , DRIVEWAY APPROACH.PLAN CHECK WAS ADJUSTED FOR $750 PLAN CHECK DEP. ---------------------------------------------------------------------------- Other Fees . . . . . . . . ART IN PUBLIC PLACES -RES 537.89 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 103.68 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI)•- RES 41.51 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged ----------------- Paid Credited Due ---------- Permit Fee Total 2183.86 ---------- -------------------- 463.25 .00 1720.61 Plan Check Total 430.21 286.75 .00 143.46 Other Fee Total 3088.08 .00 .00 3088.08 Grand Total 5702.15 750.00 .00 4952.15 / 2404- 07'34 ---7607777011 .......................... 1 ;Z 23 Bull ding Address S':-41-'9. 'I ► A 4'C�Ae.w LA QUINTA PAGE 01/01, 4uii�,t' o y_ /? P.O. BOX 1504 78-495 CALLE TAMPICO APPLICATION ONLY LA QUINTA, CALIFORNIA 92253 Lo l 250 Mailing Address 80 _ SSo -4`s.rm p . -m `.A�+ Tpae�„ City Zip Tel. Ua c�,�N� �azs3 -►�s - 1�sb - Q R t -A P=lotfl- cif t as -0-10 C A.0—IL Gae►r� I L zip 2 'Z -S 21 1 19t-44 - State Lic. City & Classlf. Lic. Afcn., tngr., Designer fo�t•tevtP Address Tel. .f ts�L. aa,Jrno► 'zee i"75 - ,o$� City Zip State p sSA '225 Lir,. 8 C � ¢ 7 LICENSED CONTRACTOR'S DECLARATION I !slab;p aftlrm that I am Ilcenee0 under provisions of Chapter a (commencing with b6Ctlon •7000) 01 Olvision 3 of the evelness and Profession Code, and my license t5 in full force aro ellect. Nar DATE OWNER-1111;ILDEq OECLARATION I hereDy affirm that i en) exempt from the Ccnlractors Llden9e Law for the following redaon: (66c. 7037.6,9Uglnes5 and Proreswons CDOe: Any city or coonly which require, a Oermif to cOnstruef. aaa, Improve. demolish, or repolr any afructure, pr'lor to ya, Iesu4n0e alto fe900's MA ap0e00M for ouch pMrlr t0 No a slpned V00ftlont that ne Y. 110en6red pursuant to Me Drovlglona Of fhe C3nuec(0r6 L,cene Low, Chapter a (com+npn,lny with Section '000) of O+ria+on 3 or fhe. 6va++vaa and Prorpggiona Code. or rA7f.,p is exempt (nprapom, ono Na bog,' for (he allayed e.vomp+lor. Any vlorathn Ol Socdpn 7031.S or any appyoant roe a ermn aubleas Ire 0006cam to a Civnparfoy of not more than pva hr.orW dNrars ( 500). ' ' I, as 0 w n 9 1 Of rha property, or my Employees wlih ,pyge9 aD Ihelr COmPanD n, will 0 0 the work, and the structure Is not intended or off rreo for gale. ($e 004, ee, ane PiofpSVOns Coca: rhe COnIftlar's License Low does not appry to eh o• r of rty Who builds or pwovpe !!aeon and who Baer loch Work h,maptt or Ihro h arrplovepg, provided Mat such ImprOverrrenls aro hof tnferoed w 0Norpo /, the building or IrgrOvarna+r Is sord wQhtn one year .a cOmpl¢Ion, lfp 6r vp the border. of Dravpig Met ne del not bued or mprOro fw the purpoSp Ol ga(e I i I, as owner of the property, am exclusively contrera!"' ce contractor5 to COR• stfuCt the p'019Ct. (Sec. 7C44, surineaa and Ptofet SioAt 772e COnfreC(Or'a License Law dova net apply 10 en owns/ of property who butlos or wwro hereon, and who Contracts for Bach ora�)eco With a Convaetogs) means" pursue„, to (he Confrac L"nae taw.) 'I I &M exerrpt under SecB. 6 P.C. fo Is red. �/r y - --1 nates_ �/ own �� — — v WORKERS' COM ATt&DECLARATION I hereby affirm that I hav6 a certiilo oI �ysent to self-lreure, or a cartllicate 01 Wbrk6r a Comp¢nsaNOn Inau ranee, Or a Oorti ' copy thereof. (Sec. 3800. LebOr Code.) Policy No. a.npshy i : Copy 19 hied with th ty. .: Certifleo y is hereby 7,,71gneo. (Tela spC11Jn nee be p"ta It alerml! R f0r one hundrad deris- (slop) vwluon or leas.) I cerllly chat In th rfo n Imp work for which this parmif is Issued, I ehall not. employ any pgLicn rn na es to bacome ¢ubiect to the Workers' Compensation Lflwr of Call a Or examplron you ahouc, OSCOnte "!,eine e.1 Me Labor co". you royst fdnhw+fh be deemed .rowFed. CONSTRUCTION LENDING AGENCY I eby afli that there is a con3ouciion Ienofng a?sney for the performance of the work which 1 permll IS issued, (Sec. 9069, civil Code.) This is k the thepermR when properly Illl47 Oti4 S:gnad and valloeted, and is subl6ot to ekpra:lOn i' wdrreun0ar is susp¢n080 for 180 days. I comfy that I have read this application and state that the above Information Is correct. I Agree to comply with all oily and county ordinances she slate Iowa relating to building construction, and h6reby authorize reprasanmtives of this oily t0 enter the above. mentioned 3ropenl• for insp¢ollon purposen. Signature Of appiicanl___.__ - _oeta_—_ Mailing A00,aae__.... City, State, LID... - BUILDING: TYPE'CONST,.--!r---OCC,GRP. A.P. Number2 2,. Legal bescriptlon T 4 : i­2% Droject Description UC -5T Is -in, SqFt. No. 1 No. own Slits, -71 Stories I) Units New Add O Alter O Repair ❑ Demolition O �•„a,c� vawauwt / Ida � PERMIT l ` AMOUNT Plan Chk. Dep. 0 VO4 1 Plan Chk. Bal. Const. Mach. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL REMARKS ZONE; BY: Minimum SetbaCk Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center LIne�_„_ Side Setback from Property Line FINAL OATS INSPECTOR 165ued by: Pate_Permit Validate0 by: Validaiion WHITE BUILDING DEPARTMENT YELLOW = APPLICANT PINKw FINANCE Coachella Valley Unified School District P.O. Pax -A47, Thermal, CA 92274 ;760) 398-5909 — Fax (760) 398-1224 Project Name: _ Owner's Name: This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEEPT: CHECK b: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Date: f1�1 D moi` Phone No. Project Address: 53-4159 1 Via 5 -rra da ".0- W U t AMA • � rT Project Description: f S FD APN • %%� - 55�0_G 3 r Tract #• Lot #'s: Type of Development: Residential � Commercial Total Square Feet of Building Area:- Y, Certification of Applicant/Owners: The person signing cc under penalty of perjury and further represents that he/she is Dated: I —,?—a —a 4Z Signature: Industrial the above information is correct and makes this statement to sign on behalf of the owner/developer. * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *I* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project 17620 65995 Approval Number of Sq -Ft - Amount per Sq.Ft. $ a• � 21 Amount Collected $ z 1 Building Permit Application C mpleted: Yes/No By: Carey M Carlson Asst. Supt., Business Serv. Agreement Existing Not Subject to Fee Prior to 1/1/87 Requirement Note: 14 _e "t -, - Certificate issued by: E1 vi ra- Mattson Signature: Office Technician NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof.. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. 09/30/02 MV:c/mydocs/devfees/certificate of compliance V A" YOUNG ENGINEERING SERVICES *Engineering •Architecture•Surveying• Building & Safety Services Letter of Transmittal To: City of La Quinta Date: 6/18/04 Project. 53-439 Via Strada Attn: Ed Randall PC#: PC# 04-3722 (2 ND Check) Tel No.: (760) 777-7012 Tract No.: We are forwarding: X By Messenger By Mail Your Pickup No. of Copies Description: 1 Redlined Plans 2 Struct calcs (old and new) 1 Truss calcs 1 Revised plans Comments: Plans are approvable. Thanks This Material Sent for: Your Files Per Your Request Your Review z Approval Checking At the request of Other By: Eric Frenzel Phone # 760-360-5770 77-804 Wildcat Drive, Suite C Palm Desert, CA 92211 (760) 360-5770 - Bronz Young N diL) �. RrCORDING REQUESTED BY: Fidelity National Title Company E:Zrow No. 8687 -CAH Title Order No. When Recorded Mail Document and Tax Statement To: Hideaway La Quinta, LLC 2905 Woodside Road Woodside, CA 94062 DOC p 2004-0175782 03/12/2004 Conformed Copy Has not been compared with original Gary L Orso Assessor,, CountyClerk AF'IV: +)-7a _S -q©- 0 -3H -A SPACE ABOVE THIS LINE FOR RECORDER'S USE TP_ ©aD , 1 bo GRANT DEED The undersigned grantor(s) declare(s) ---T' Documentary transfer tax is $ /39. /5 I X ) computed on full value of property conveyed, or [ I computed on full value less value of liens or encumbrances remaining at time of sale, r [ ) Unincorporated Area City of La Quinta lT FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Stewart Woodard and Renee Woodard, Husband and Wife as Joint Tenants hereby GRANT(S) to Hideaway La Quinta, LLC a California limited liability company in the City of La Quinta, County of Riverside, State of California: LOT 250, OF AMENDED TRACT NO. 29894-2, AS SHOWN ON A SUBDIVISION MAP RECORDED ON DECEMBER 12, 2002, IN THE COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 327, PAGES 56 TO 88 OF MISCELLANEOUS MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. DATED: February 25, 2004 STATE OF CALIfQRNIA COUNTY OF QN S – before me, _ f rsonaII1� appeared 0.0 C�(\C�1 or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is mer subscribed to the within instrument and acknowledged to me that he/sh (e executed the same in his/her/t r thorized capacity(ies), and that by his/her/ eir s gnature(s) on the instrument the person(s), or t e entity upon behalf of which the Person(s) acted, expo ed the ir(strument. Witness my harm an"ffici.4 seal. Signature Stewart Woodard &ee Woodard v v MAIL TAX STATEMENTS AS DIRECTED ABOVE I— „a01 GRANT DEED GOVERNMENT CODE 27361.7 I HEREBY CERTIFY UNDER PENALTY OF PERJURY THAT THE NOTARY SEAL ON THE DOCUMENT TO WHICH THIS IS ATTACHED. READS AS FOLLOWS: NAME OF NOTARY: DATE COMMISSION EXPIRES: COMMISSION NUMBER: COUNTY WHERE BONDED: PLACE OF EXECUTION: DATE: /IFIEL-IATY NATIONAL TITLE BUILDER SERVICES CATHERINE A. HAMMONS APRIL 15, 2004 1258348 RIVERSIDE RIVERSIDE COUNTY, CALIFORNIA MARCH 12, 2004 62:19 PM P.61 TESTING .' CF -4R Dv Date gM6 -� Builder Name Piers Number Sample Group Number -•y^'y tl awry r / Dote Semple House Number ._.__ HERS Provider; Street Address: C/YG �� city/state/zip: Copies to: Builder, HERS Provider R3 A ER C AN ST TE� The house was; Tested ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comJJy with the diagnostic tested compliance requirements as checked on this form. Distribution system is fully ducted (i,e., does not use building cavities as plenums or platform returns in lieu f ducts) Ld Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used In combination Ith cloth backed, rubber adhesive duct tape to seal leaks at duct connections. MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Duct Pressurization Test Results (CFM ® 25 Pa) Test Leakage Flow In CFM If fan flow is calculated as 400cfm/ton x number of tons enter calculated value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) = Check Box for Pass or Fail (Pass=6% or less) IfTHERMOSTATIC EXPANSION VALVE (TXV)or Commis Measured values 7-71kag3 equivalent v - Yes ❑ No Thermostatic Expansion Valve (or Commission approved equivalent) is installed and Access is provided for inspection Yes Is a pass MINIMUM REQUIREMENTS FOR DUCT DI=SIGN COMPLIANCE CREDIT 4 Yes O No ACCA Manual D Design requirements have been met (rater has verified that actual Installation matches values in CF -1 R and design on plan. 0 Yes ❑ No TXV is installed or Fan flow has been verified. If no TXV, verified fan flow matches design from CF -1 R. Measured Fan Flow = Yes for both 1 and 2 is a Pass d 2, S -Zi? 5: Z/ Pass Fail 11 ass Fail Pass Fail Certificate of Occupancy 9 4 r?. L•waeoaern �� YC,GoF 9ti5 Builing & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the -time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 53-439 VIA STRADA . Use classification: SINGLE FAMILY DWELLING Building Permit No.: 04-3722 Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL Owner of Building: WOODARD DEVELOPMENT Address: 80-880 VISTA BONITA TRAIL City, ST, ZIP: LA QUINTA, CA 92253 By: STEVE TRAXEL �^ &4-% Date: 08-05-2005 Building Official POST IN A CONSPICUOUS PLACE I - TITLE 24 REPORT I Title 24 Report for: WOODARD-CASILLI RESIDENCE Lot 250, The Hideaway La quinta, Ca 92253 Project Desig THE WOODARD C 80-880 Vista Bonii La Quinta, Ca 9: (760) 775-70F L% r., OF IA QUINT ING&SAFEDEPT.pWAYRAPPRO TION 53 FOR fBf DATE , Report Prepared By: R. Krown CEA R01-93-204 Desert Energy Services P.O. Box 621 Rancho Mirage, CA 92270-0621 (760) 564-2044 Cnrtitln0 Energy Analyst Rid=d F. Kimn r rNR .62o F-; r r R:'Qw .k:A0EC L.r,,i� �',^.�8 C� o� OI.lKS� '�'i Job Number: 4019 Date: 4/1/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. 3.1 This program developed by EnergySoft, LLC (415) 883-5900. s Job Number: 4019 User Number: 2366 53`939 via s�t�� o�rt� • wPa loot�c TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary Form ENV -3 Proposed Construction Assembly HVAC System Heating and Cooling Loads Summary Job Number. 4019 + a. 1 2 3 8 10 17 20 User Number: 2366 Certificate of Compliance: Residential (Part 1 of 2) CF -IR WOODARD-CASILLI RESIDENCE 4/1/2004 Project Title Date Lot 250, The Hideaway La quinta Project Address Building Permit # Desert Energy Services (760) 564-2044 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check 1 Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 4,779 f? Average Ceiling Height:._ 11.3 ft Total Conditioned Slab Area: 4,779 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (East) 90 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Const. Frame Assemh Location/Comments Jc, garage, typical, etc.) Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Tile/Aftic/R-38/Gyp Wood 0.026 Exterior Roof R-21 Wall (W.21.24.16) Wood 0.059 Exterior Wall R-21 Partition Wood 0.057 Exterior Wall Solid Wood Door Wood 0.387 Exterior Door Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation FENESTRATION ghibelinn 1levik%,& Type Orientation Area Fenestration Exterior Overhang Side Fins SF -F or SHGC Shading Yes / No Yes / No Front (East) 54.0 1.25 0.67 Bug Screen ❑ ❑ X❑ Front (East) 198.0 0.47 0.48 Bug Screen X❑ ❑ ❑ Q Front (East) 66.0 0.45 0.52 Bug Screen ❑ X❑ ❑ X❑ Left (South) 104.0 0.45 0.52 Bug Screen ❑ X❑ ❑ X❑ Right (North) 93.0 0.45 0.52 Bug Screen❑ X❑ ❑ X❑ Rear (West) 59.5 0.47 0.48 Bug Screen❑ X❑ ❑ X❑ Rear (West) 505.0 0.47 0.48 Bug Screen X❑ ❑ ❑ X❑ Right (North) 30.0 0.53 0.48 Bug Screen ❑ X❑ ❑ X❑ Rear (lest) 80.0 0.64 0.53 Bug Screen X❑ ❑ ❑ Left (South) 112.0 0.47 0.48 Bug Screen ❑ X❑ ❑ X❑ Rear (West) 3.1 0.45 0.52 Bug Screen ❑ X❑ ❑ X❑ Right (North) 81.3 0.45 0.52 Bug Screen X❑ ❑ ❑ X❑ Run InWation Time: 0M 11 11:11717 Run 7 EnegyPro 3.1 Sy EnergySoft User Number. 2366 Job Number. 4019 Pa e:3 of 23 Certificate of _Compliance: Residential (Part 1 of 2) CF -111 WOODARD-CASILLI RESIDENCE 4/1/2004 Project Title Date Lot 250, The Hideaway La quinta Project Address Building Permit # Desert Energy Services (760) 564-2044 Plan Check I Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 4,779 f? Average Ceiling Height: 11.3 ft Total Conditioned Slab Area: 4,779 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition E1 Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (East) 90 deg Number of Dwelling Units: 1.00 Number of Stories: 1 Component FENESTRATION Floor Construction Type: ® Slab Floor ❑ Raised Floor Const. Frame Assembly Location/Comments Type U -Value (attic, garage, typical, etc. Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF r SHQQ Shading Yes / No Yes / No Right (North) 24.0 0.64 0.53 Bug Screen X❑ ❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation / C 7 EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 4019 Pa e:4 of 23 Certificate of Compliance: Residential (Part 2 of 2) CF -IR WOODARD-CASILLI RESIDENCE 4/1/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (fumace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Fumam 80% AFUE Ducts in Attic 4.2 Setback East LivingBed 102 Central Furnace 80% AFUE Ducts in Attic 42 Setback Right LivingBed 105 Central Furnace 80% AFUE. Ducts in Attic 4.2 Setback Muster Suite rpntral Fimnarp 80% AFUE Duds in Attic 4.2 Setback Guest Suite Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 14.0 SEER Duds in Attic 42 Setback Fact t iving/Bed 102 Split Air Conditioner 14 0 SEER Ducts in Attic 42 Setback Right ivina 105 Split Air Conditioner 16.0 SEER Duds in Attic 4.2 Setback Master Suite Split Air Conditioner 16.0 SEER Duds in Attic 4.2 Setback Guest Suite WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A_O. SMITH FPS -50-224 Small Gas Recirc/Timer 1 43,000 50 0.60 n/a n/a n/a A.O. SMITH FPS -50-224 Small Gas Recirc/Timer 1 43.000 50 0.60 n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS Volume Dampers at: Bed 102 / E.living; Bed 105 / W.Living; For Zonal Control Credits COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using dud sealing and TXV 9 requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: THE WOODARD GROUP Address: 80-880 Vista Bonita Trail La Quinta, Ca 92253 Telephone: 760 775-7088 Li v (sl (a ) Enforcement Agency Name: Title/Firm: Address: Telephone: Name: R.Krown CEA R01-93-204 Title/Firm: Desert Energy Services Address: P.O. Box 621 Rancho Mirage, CA 92270-0621 Telene: 760 564-2044 / 0 -(sl6a u (ate) IEneMyPro 3.1 By EneraySoft User Number. 2366 Job Number. 4019 Paae:5 of 23 1 Certificate of Compliance: Residential (Addendum) CF -1 R WOODARD-CASILLI RESIDENCE 4/1/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System "East Living/Bed 102" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "East Living/Bed 102" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1007 sqft Covered Slab Floor, 3.50" thick at Living/Galleria/Laundry HIGH MASS Design(see C -2R) - Verify Thermal Mass: 226 sqft Covered Slab Floor, 3.50" thick at Bed 102 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 119 sqft Exposed Slab Floor, 3.50" thick at Bed 102 The HVAC System 'Right Living/Bed 105" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System 'Right Living/Bed 105" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) -Verify Thermal Mass: 1510 sqft Exposed Slab Floor, 3.50" thick at Media/Family/Kitchen HIGH MASS Design(see C -2R) - Verify Thermal Mass: 229 sqft Covered Slab Floor, 3.50" thick at Bed 105 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 88 sqft Exposed Slab Floor, 3.50" thick at Bed 105 The HVAC System "Master Suite" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Master Suite" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 717 sqft Covered Slab Floor, 3.50" thick at Master Suite HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field The HVAC System "East Living/Bed 102" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "East Living/Bed 102" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System 'Right Living/Bed 105" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Right Living/Bed 105" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Master Suite" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Master Suite" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Guest Suite" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Ru Time: / Code; EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number: 4019 Page:6 of 23 r r Certificate of Compliance: Residential (Addendum CF -1R WOODARD-CASILLI RESIDENCE 4/1/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies o 4....y ..I uIc aF—u aI JwL1114aUV11 anU UVGU111CUt4UOr1 5UUMIEWO. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 257 sqft Exposed Slab Floor, 3.50" thick at Master Suite The HVAC System "Guest Suite" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Guest Suite" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 280 sqft Covered Slab Floor, 3.50" thick at Guest Bedrooms HIGH MASS Design(see C -2R) - Verify Thermal Mass: 346 sqft Exposed Slab Floor, 3.50" thick at Guest Bedrooms HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS rlv�wcl. I u¢ nGr�J KOLWI IIIUM& YVGU111CIIl UIC IICIu vurnivaUun anu wagnosuc Testing oT [nese measures on a TOrm GF -6R. Plan Field The HVAC System "Guest Suite" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run initiation Time: 04!0110411:07:17 - Run Code: 1080846437 EnergyPro 3.1 By EnergySoft User Number: 2366 Job Number: 4019 Page:7 of 23 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures 1150(a): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturers labeled R -Value. 1150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ® not apply to exterior mass walls). '§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ®§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑X §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. lAl §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. a01500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemallextemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 4019 Page:8 of 23 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. ucQ%.r%rr I IVIV Instructions: Check or initial applicable boxes or enter N/A if not applicable. Space Conditioning, Water Heating and Plumbing System Measures: (continued) -- — n�§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. IK I §114: Pool and Spa Heating Systems and Equipment — 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. ® §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) §118 (f): Cool Roof material meet specified criteria Lighti Measures DESIGNER J ENFORCEMENT ------ - ------ -- - --- - - I� I §150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. 1I§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft — - User Number: 2366 Job Number: 4019 Page:9 of 23 Computer Method Summary , (Part 1 of 3) C -2R Prot HARD-CASILLI-RESIDEN.C`E Date 4/1/2094 I ot 2�e Hideaway c}uinta Project Ad rens Building Permit p 02esert Fner�SQ vices (760 5) 64-2044 Plan Check/Date Documentation A or Telephone Performance 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 4.05 4.09 Space Cooling 37.04 34.59 Domestic Hot Water 5.96 7.72 Totals 47.05 46.40 Percent better than Standard: BUILDING I Total Conditioned Floor Area: 4,779 ft2 Building Type: Single Fam Detached Building Front Orientation: (East) 90 deg Number of Dwelling Units: 1.00 Number of Stories: 1 BUILDING ZONE INFORMATION Zone Name Eastlixing/BecL102— R' t ivi gBetL05 J1Aaster Suite G_uest_Suite OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Floor Area Volume Ronf 1.007 Q 026_ __0 0 wall 147 _0.059 go —90 Wall— _�27- —0.0.59 190 go Wall— 47 0.059- _0 90 wall —234 Q05Z 0 9G Door 26 090 - Roof —349 0.026 0 0 all 170 0.059 90 90_ Wall 86 0.059 270 90 ANW — 91 0.059 _0_ 90_ Wall 180 0 052 0 9a Root_ _i,siG _x_026 Wall 58 0.059 90. 9G !Nall 161 0.0.5k 180 90_ Wall —326 _0.052 270 90 Befall— 55 0.059 0. 90_ wall 58 _0057 _0. 90 Roof 317 ---D-026- —0_ 0 Nall— 98 0.052 90 90_ 5A(all— 65 _0.05k ._279_ 90 Wali -----t6Q 0.G% 0 _90_ Wall 118 _O.QSZ 90_ go Rnnf _974_ 0.026 —0 0 NMI 340 0.052 —180_ 90_ Nall— 204 0059 _270_ go Wall 165 0.059 0 _90 Wall— 150 —0-051 —9D- 90 Roof— 626 Q026 0 Wall —1910 059 ---K 90_ I -5,2 —LUZ 974 s26 Solar Gains Y/N - -0.04 2.45 -1.76 0.65 1.4% Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Total Fenestration Area: 29.5% Total Conditioned Volume: 53,798 ft 3 Total Conditioned Slab Area: 4,779 ft 2 # of Thermostat Vent Units Zone Type Type Hgt. Area 0 28 living _LMngStat— —2 _n 0.38 Living _LiYirigstat_ 0.20 Sleeping SleepingStat ]3 _�leepin9 -SleepingSlat-. • —_2 —N.a Form 3 Reference Location / Comments EURN/AC-1 -EURN/1 El RN/AC-1 Ft IRN/ACS__ F(JRN/AC-1 EURN/AGA FURN/AC-1 FURN/AC_] EURN/AC-1 EURNIAC-1 FORN/AC-1 .EURN/AC2 Et RN/AC-2 EL RN/AC-2 FURN/Af -2 .EURN/AC-2 EURN/AC-2 FURNAf-2 FURN/AC--2 FURN/AC-2 F_URNIAC-2 FURN/AC-2 .EURN/AC--3 FURN/AC 3 El RN/AC-3 FURN/Ar-3 EURN/9C-3 FURNACA F_URN/AC=4 EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 4019 Page: 10 of 23 1 I. Computer Method Summary (Part 1 of 3) C -2R WOODARD-CAS.II I I RFSID N . --- Project Title _t35 The Hideaway La_quinta Project A rens Desert Fnerqv Sentices (760) 564-2044 Documentation A or Telephone Source Energy Use Standard Proposed (kBtulsf-yr) Design Design Space Heating 4.05 4.09 Space Cooling 37.04 34.59 Domestic Hot Water 5.96 7.72 . Totals 47.05 46.40 Total Conditioned Floor Area: 4,779 ft2 Building Type: Single Fam Detached Building Front Orientation: (East) 90 deg Number of Dwelling Units: 1.00 Number of Stories: 1 BUILDING ZONE INFORMATION Zone Name Floor Area Volume OPAQUE SURFACESSolar Act. Gains Type Area U -Fac. Azm. Tilt Y / N Compliance Margin -0.04 2.45 -1.76 0.65 Building Permit # Plan Check/Date Floor Construction Type: ❑ Raised Floor g] Slab Floor Total Fenestration Area: 29.5% Total Conditioned Volume: 53,798 ft 3 Total Conditioned Slab Area: 4,779 ft 2 # of Thermostat Vent Units Zone Type Type Hgt. Area Form 3 Reference Wall _234 _0259- —180_ _90 Wall 20 n.059 27n gn Wall 235 0_059_ 0 9n Wall 55 005.7 0_ 90 Dior 0 0.381 _0 90 _ L ❑ R ❑ ❑❑ ❑ ❑❑ ❑❑ H ❑❑ ❑ ❑ ❑ ❑ ❑ H H ❑ ❑ R-21 Wall (1N_21.2x6.16) R-21 Wall (W 21-2x6 16) R-21 Wall (W2,1 M 16) R-21 Partition Solid Wo9d_Qoor _ -- - - - -- Location / Comments FLIRN/AC-d El IRN/A ...4 FI IRN/AC.4 EURN/AC-4 F(JRN/ACS EnergyPm 3.1 By EnergySoft User Number. 2366 Job Number. 4019 Pane: 11 of 23 Computer Method Summary(Part 2 of 3) C -2R WOODARD-C_ASILLI RESIDENCE 4/1/2004 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments -t Ondow f-ronL.- (East) _ 54_0 -J-250- 0.61 90_ SO Single-Metal.Tinted-Defauk _ -EU.RNLAC-1 2 Window Front East 153.0 0.470 0.48 90 90 Fltwd 530/3300 Lo E Brz _ FURN/AC-1 3 Window Front (East_ _ 54.0 0.450 0.52 90 90 Fltwd 530/3300 Lo E Brz FURN/AC-1 _ 4 Window Left (South) 54.0 0.450 0.52 180 90 Fflwd 530/3300 Lo E Brz FURN/AC-1 5 Window Right (North) 54.0 0.450 0.52 0 90 Fltwd 530/3300 Lo E Brz FURN AC -1 6 Window Rear VWest). 59.5 0.470 0.48 270 90 Fltwd 530/3300 Lo E Brz FURN/AC-1 L Window Richt (Nottt_i) _ 14.0 0.450 0.52 0 90 Fltwd 530/3300 Lo E Brz ftJRNIAC-1 8 Window Rear est 200.0 0.470 0.48 270 90 Fltwd 530/3300 Lo E Brz FURN/AC-2 3 Window Rear estl M -A QA7-0_ QA8 270 90 Fltwd 530/3300 Lo E Brz TURN/Acca 10. Window Right f orth) 30.0 0539 0.48 0 90 F1twdM0Q.30Q Lo E Brz_ -E RN/AC-2 " Window Front (East) 12.0 0.450 0.52 94 90 Fltwd 530/3300 Lo E Brz FURN/AC-2 12 Window Rear -(Westj 80.0 0.640 0.53 270 90 Fltwd 530/3300 Lo E Brz _ FURN/AC-2 J-3 Window Left (S.o W _56.0 0.470 0.48 1$0 -00 F11 W D13.3MLo-E Brz EURN/AC_3 14 Window Rear (West)_ 80.0 0.470 0.48 270 90 Fttwd 530/3300 Lo E Brz FURN/AC-3 15 Window Rear (West) 90.0 0.470. 0.48 270 90 Fltwd 530/3300 Lo E Brz _ FURN/AC-3 16 Window Rear est 3.1 0.450 0.52 270 90 Fltwd 530/3300 Lo E Brz FURN/AC-3 17 Window Right (North) 25.0 0.450_ 0.52 0 90 Fttwd 530/3300 Lo E Brz FURN/AC-3 18 Window Richt (_North) 40.0 OA50 0.52 0 90 Fltwd 530/3300 Lo E Brz FURN/AC-3 J1 Window Front .(EaM --A5-0- 0-470 0.48 90 90 F MMQ0J-o-E-Bv BURN/AC- -1-20 Window Left South 56.0 0.470 0.48 180 90 Fltwd 530/3300 Lo E Brz FURN/AC-4 21 Window Left South 32.0 0.450 0.52 180 90 Fltwd 530/3300 Lo E Brz FURN/AC-4 22 Window Left (South) 18.0 0.450 0.52 180 90 Fltwd 530/3300 Lo E Brz FURN/AC-4 23 Window Right (North) 41.3 0.450 0.52 0 90 Fltwd 530/3300 Lo E Brz FURN/AC-4 24 Window Right North 24.0 0.640 0.53 0 90 Fkwd 530/3300 Lo E Brz FURN/AC-4 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type _ SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 9.0 6.0 17.0 0.1 17.0 17.0 2 Bug Screen 0.76 9.0 17.0 3.0 0.1 99.0 99.0 3 Bug Screen _ 0.76 _ 4 Bug Screen 0.76 5 Bug Screen _ 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9.0 17.0 17.0 0.1 990 99.0 9 _ Bug Screen 0.76 10.0 -135 17.0 0.1 99.0 15.0 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 10.0 8.0 17.0 0.1 3.0 99.0 13 Bug Screen 0.76 14 Bug Screen_ _ 0.76 10.0 8.0 9.0 0.1 99.0 3.0 _ 15 Bug Screen 0.76 10.0 9.0 5.0 0.1 99.0 16 _ Bug Screen 0.76 _ _99.0 17 Bug Screen 0.76 18 Bug Screen 0.76 10.0 4.0 99.0 0.1 99.0 99.0 19 _ Bug Screen 0.76 7.5 6.0 1.0 0.1 99.0 99.0 20 Bug Screen 0.76 21 _ Bug Screen 0.76 _ 22 Bug Screen 0.76 23 Bug Screen 0.76 --7.5 5.5 2.0 0.1 99.0 99.0 24 Bug Screen 0.76 8.0 3.0 2.0 0.1 99.0 99.0 Run lnitAW-n-Zjme: 0410110411:Q7:1 7 Run Code: 1 0845437 EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 4019 Page: 12 of 23 3of3 WOODARD-CASILLI RESIDENCE Project Title F2 Length Factor Insulation R -Val. Depth 4/1/2004 Date THERMAL MASS FOR HIGH MASS DESIGN 20 0_76 0.0 0 F-URN/AC-1 Area Thick. Heat _Q Inside Location Type _ (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments S&acrm1"eayyweight _ 1,0.07- _3.50. _28. AM n/a —2 EURN/AC1_LSlab-on Grade oncrete. HeayM ght__ 226 33^50 28 0.Qa n/a 2 FURN/AC-1 / lab Qn Grade SQncrete,l•teaymmght_ -- 1_9 -3M 2$ -9fl n!a _ 0 EURN AC_1J—Wat Concre a Hea ei hg t 15-1-Q 3_50 28. Q.9M n/a 0 -Qn-G-mde FURN/AC-2 / Slab on Qradg .Concrete-Eeal4weight—_ _225. 3M _28 -0-0 nLa _2 F_URN/AC--2-LSjab9nAGrade PERIMETER LOSSES Type F2 Length Factor Insulation R -Val. Depth Location / Comments Slab Perimeter 20 0_76 0.0 0 F-URN/AC-1 Slab-Eedmeter _ _38 0_76 0.0 _Q EURN/AC-1 — - -Slab pmimeser__ _ _22 Qi7-6 0.0 2 EURN/AC-1 SlahPerimeter _ -076 --D-Q 2 _ EURWAC2 Slab-Redmeter _ 340_76 0.0 _--Q FURN/ACS HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiencyy and Location Duct Thermostat Location / pump, etc.) — (AFUE/HSPFKducts/attic, etc.) R -Value Type Comments Central Fumace 8O AFUE Quos in Attic 4.2 Setback FASJL ivingBed 102 Central Furnace T 80%A—FU E Ducts in Attic 4.2 Setback Right Living/Bed 105 Central Furnace 80%A_FU E Ducts in Attic 4.2 etback Mast�Suite Central Furnace 80%AFUE Ducts in Attic 4.2 Setback Guest Suite Hydronic Piping pipe Pipe Insul. System Name _ Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback Eas iv'ng/Red 102 Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback Right Living/Bed 105 Split Air Conditioner 16.0 SEER Ducts in Attic 4.2 Setback Master Suite Split Air Conditioner 16.0 SEER Ducts in Attic 4.2 Setback Guest Suite WATER HEATING SYSTEMS Ratedl Tank Energy Fact? Tank Insul. Water Heater Water Heater Distribution # in Input Cap. 1 or Recovery Standby R -Value System Name Type Type Syst (Btu/hr) (al) Efficiency Loss (%) Ext A.O. SMITH FPS -50-224 Small Gas_ Becima mer 1 ---nM 50 am We A.O. SMITH FPS -50-224 Small Gas Recirc/Timer 1 43.000 50 ^0.60 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Volume Dampers at: Bed 102 / E.living; Bed 105 / W.Living; For Zonal Control Credits Run Initiation Time: 04/0110411.07.17 Run Code: 1080846437 EnergyPro 3.1 By EnergySoft User Number: 2366 Job Number. 4019 Page: 13 of 23 Computer Method Summary (Part 3 of 3) C -2R WOODARD-CASILLI RESIDENCE 4/1/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments ��rgta tJeavywi9ttt —88 _3.50 _2a USB. n/a -.0. EURWAC1J_Slab-on_Grade_ Concrete Heavywei hg t _ _ 717 3.50 28 0_98 n-/0 2 TURN/AC-3 / Slab on Gra e Concreta,Haawweight-__ _257 3M 2$ 0.98 n/a —Q FUR A -C=3 / $10-otUG-mde Concrete. HeamMeieight 280 3.50 28 . n/a _ 2 FU—RN/AC-4 /_ la on Grade -C=rete,- eavvweigbt__ _3 3.50 28 0.98 n/a 0 BU /AC -4 / SIab-on-G-tade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments -lab Berim tQr _ --19 -U6 0--0 0 _ FUR- N/AC-2 Slab-Berimeter 8.5. -0-76 0.0.0 FURN/AC-3 - Stab Perimeter _20 -0�76. U_0 _--Q EURN/AC-3 Slab Perimeter _ —31 -0-M --D-O 0 EURWACA _ Slab -Perimeter ---64 0.76 0.0 _Q EURNIACA -- — HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments WATER HEATING SYSTEMS Rated' Tank Energy Factl 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. 1102 / E.living; 1105 / W.Living; Zonal Control Credits Run Initiation Time: 04/01/0411:07:17 Run Code: 1080846437 EnergyPro 3.1 By EnemvSoR User Number: 2366 Job Number. 4019 Pam: 14 of 23 Computer Method Summary (Addendum) C -2R WOODARD-CASILLI RESIDENCE 4/1/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. cw The HVAC System "East Living/Bed 102" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "East Living/Bed 102" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1007 sqft Covered Slab Floor, 3.50" thick at Living/Galleria/Laundry HIGH MASS Design(see C -21R) - Verify Thermal Mass: 226 sqft Covered Slab Floor, 3.50" thick at Bed 102 HIGH MASS Design(see C -21R) -Verify Thermal Mass: 119 sqft Exposed Slab Floor, 3.50" thick at Bed 102 The HVAC System "Right Living/Bed 105" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System 'Right Living/Bed 105" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) -Verity Thermal Mass: 1510 sqft Exposed Slab Floor, 3.50" thick at Media/Family/Kitchen HIGH MASS Design(see C -2R) - Verify Thermal Mass: 229 sqft Covered Slab Floor, 3.50" thick at Bed 105 HIGH MASS Design(see C -21R) - Verify Thermal Mass: 88 sqft Exposed Slab Floor, 3.50" thick at Bed 105 The HVAC System "Master Suite" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Master Suite" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 717 sqft Covered Slab Floor, 3.50" thick at Master Suite HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field The HVAC System "East Living/Bed 102" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "East Living/Bed 102" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System 'Right Living/Bed 105" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System 'Right Living/Bed 105" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Master Suite" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Master Suite" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Guest Suite" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. EnergyPro 3.1 By EnergySoft User Number: 2366 Job Number: 4019 Page: 15 of 23 Computer Method Summary (Addendum) C -2R WOODARD-CASILLI RESIDENCE 4/1/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies �.-.-.-.- �.. •.... •+..�-4-7 we arc aFwulal Juaunwuvn amu vvGU111VULauurl SUOrrlIXWO. Plan I Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 257 sqft Exposed Slab Floor, 3.50" thick at Master Suite The HVAC System "Guest Suite" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Guest Suite" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual HIGH MASS Design(see C -2R) - Verify Thermal Mass: 280 sqft Covered Slab Floor, 3.50" thick at Guest Bedrooms HIGH MASS Design(see C -2R) - Verify Thermal Mass: 346 sqft Exposed Slab Floor, 3.50" thick at Guest Bedrooms HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider The HERS rater m t d t th f Id us men a ie ve rf --en and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "Guest Suite" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 04/0•x/0411• •17 Run n Code• 1080§ EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number: 4019 Page: 16 of 23 ;ROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE WOODARD-CASILLI RESIDENCE 4/1/2004 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Roofing, Slate 2 Membrane, Vapor -Permeable Felt 3 ASSEMBLY NAMEITile/Attic/R-38/Gyp 4 Air Space 5 ASSEMBLY Floor Gypsum or Plaster Board 7 TYPE (check one) Wall 3.86 W p W X Ceiling / Roof INSIDE SURFACE AIR FILM 0.610 FRAMING MATERIAL Wppd Z O FRAMING %/o o 10 Framing °k 17.3 TOTAL HC 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) SUBTOTAL R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Roofing, Slate 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Air Space 5 Insulation, Mineral Fiber, R-38 6 Gypsum or Plaster Board 7 0.39 8 3.86 9 1.39 2.08 INSIDE SURFACE AIR FILM SUBTOTAL R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.050 0.050 0.060 0.060 0.620 0.620 0.800 12.375 38.000 11.385 0.450 0.450 0.39 1.42 3.86 0.36 1.39 2.08 0.610 0.610 40.76 25.7 RG Kr -HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) members. [ 0.0245 6.25 0.30 1.88 0.06 0.35 0.02 1.421 0.29 0.41 3.64 0.39 1.42 3.86 0.36 1.39 2.08 0.26 0.54 17.3 TOTAL HC 5 7 *NOTE: Wei ht and Specific Heat values for materials peneftated by wood framing Include the effects of the framing members. [ 0.0245 X 0.90 ] + [ 0.0389 X 1 / Rc 1 - (Fr-/. / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number 4019 Page:17 of 23 . 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE WOODARD-CASILLI RESIDENCE 4/1/2004 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-21 4 Gypsum or Plaster Board ASSEMBLY NAME R-21 Partition 6 0.98 7 ASSEMBLY Floor 9 TYPE (check one) Wall 0.680 0 W Ceiling / Roof H FRAMING MATERIAL Wood Z 7 4 TOTAL HC 2 2 p FRAMING % 15 % Framing 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-21 4 Gypsum or Plaster Board 5 2.63 6 0.98 7 0.26 8 9 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.5621 0.562 0.0601 0.060 21.000 5.445 0.450 0.450 2.63 0.37 0.98 2.08 0.26 0.54 0.680 0.680 12.92 7.37 KG Ki (Jl�llu 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) members. [ 0.0436 2.60 0.26 0.68 0.06 0.35 0.02 2.63 0.37 0.98 2.08 0.26 0.54 7 4 TOTAL HC 2 2 °NOTE: Weight and Specific Heat values for materials ponetraftd by wood framing include the effects of the framing members. [ 0.0436 X 0.85 ] + [ 0.13571 X 1 0.15 1 1 Rc 1- (Fr% 1100) 1/ Rf Fr% 1100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number: 2366 Job Number: 4019 Paw 18 of 23 1 . , PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE WOODARD-CASILLI RESIDENCE I 4/1/2004 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Air Space 3 ASSEMBLY NAME linterior Air Wall 0.39 5 ASSEMBLY Floor 0.54 7 TYPE (check one) x Wall 1 / Rc p W Ceiling / Roof INSIDE SURFACE AIR FILM 0.680 52 FRAMING MATERIAL W0°d O FRAMING % 15 % Framing % 5.7 TOTAL HC 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) THICK- NESS (in.) 0.500 3.500 0.500 SUBTOTA R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board 2 Air Space 3 Gypsum or Plaster Board 4 0.39 5 2.08 6 0.54 7 = 8 1 / Rc 9 1 / Rf Fr% 1100 INSIDE SURFACE AIR FILM THICK- NESS (in.) 0.500 3.500 0.500 SUBTOTA R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.4501 0.450 0.850 3.465 0.450 0.450 0.39 0.60 2.08 0.26 0.54 X 0.15 ] = 0.356 1 / Rc 1 - (Fr -/o/ 100) 1 / Rf Fr% 1100 0.6801 0.680 2.60 5.22 Kc Kr 0�ffl=] *HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) members. 2.08 0.26 0.54 1.53 0.39 0.60 2.08 0.26 0.54 X 0.15 ] = 0.356 1 / Rc 1 - (Fr -/o/ 100) 1 / Rf Fr% 1100 ASSEMBLY U -VALUE 5.7 TOTAL HC 1 7 *NOTE. Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.3846 X 0.85 ] + [ 0.1918 X 0.15 ] = 0.356 1 / Rc 1 - (Fr -/o/ 100) 1 / Rf Fr% 1100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number: 2366 Job Number: 4019 Page:19 of 23 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE , WOODARD-CASILLI RESIDENCE 4/1/2004 SYSTEM NAME FLOOR AREA East Living/Bed 102 1.352 Number of Systems 1 Heating System Output per System 89,000 Total Output (Btuh) 89,000 Output (Btuh/sgft) 65.8 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 42.9 Total Output (sgftf Ton) 279.7 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.48 Airflow (cfm/Ton) 413.8 Outside Air (%) 0.0 Outside Air (cfmisgft) 0.00 Note: values above given at ARI conditions 26.0 OF 69.3 OF Outside Air 0 0 cfm Supply Fan 2000 dim 69.3 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 39,852 -554 31184 BDP CO 395CAV060111/598AN060 45,228 3,357 Total Adjusted System Output 45,228 3,357 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm 69.30F ® 111.10F Heating Coil h Return Air Ducts 4 115.0 / 73.5 OF 78.9 162.3 OF 78.9 162.3 OF® 57.6 / 54.6 OF Outside Air O 0 cfm Supply Fan 2000 cfm 78.9/62.3 of Cooling Coil h Return Air Ducts i 3.1 By EnergySoft User Number: 2366 Job Number: 4019 89,000 89,000 Jan 12 am Supply Air Ducts 110.5 OF ROOMS 70.0 OF Supply Air Ducts 58.5/54.9 OF 40.5% R.H. ROOMS 78.0/62.0 OF of 23 r IHVAC SYSTEM HEATING AND COOLING LOADS SUMMARY _ PROJECT NAME DATE WOODARD-CASILLI RESIDENCE 4/1/2004 SYSTEM NAME FLOOR AREA Right Living/Bed 105 1,827 Number of Systems 1 Heating System Output per System 89,000 Total Output (Btuh) 89,000 Output (Btuh/sgft) 48.7 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sqft) 31.7 Total Output (sqf rron) 378.0 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.09 Airflow (cfm/Ton) 413.8 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 of 69.3 OF Outside •AirJ- 0 cfm Supply Fan 2000 cfm 69.3 of 15.0 / 73.5 of Outside 1 0 cfm 78.8 / 62.2 of 69.3 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 1,547 32,482 -772 F 687 29,561 0 1,624 1,478 0 0 0 0 0 0 0 0 0 1,624 1,478 35 730 -772 32 517 BDP CO 395CAV060111/598AN060 45,244 3,263 89,000 Total Adjusted System Output 45,244 3,263 89,000 (Adjusted for Peak Design Conditions) Heating Coil TIME OF SYSTEM PEAK I Aug 2 pm l I Jan 12 am h Return Air Ducts 4 78.8 / 62.2 of 78.8 / 62.2 of 57.5 / 54.5 of 0 Supply Fan 2000 cfm Cooling Coil h Return Air Ducts i User Number. 2366 Job Number. 4019 Supply Air Ducts 110.4 of ROOMS 70.0 of Supply Air Ducts 58.3 / 54.8 of 40.2% R.H. ROOMS 78.0 / 61.9 of of 23 'IHVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE WOODARD-CASILLI RESIDENCE 4/1/2004 SYSTEM NAME FLOOR AREA Master Suite 974 Number of Systems 1 Heating System Output per System 35,000 Total Output (Btuh) 35,000 Output (Btuh/sgft) 35.9 Cooling System Output per System 40,000 Total Output (Btuh) 40,000 Total Output (Tons) 3.3 Total Output (Btuh/sgft) 41.1 Total Output (sqf rron) 292.2 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sgft) 1.23 Airflow (cfm/Ton) 360.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 4EATING SYSTEM PSYCHROME 26.0 OF 69.3 of Outside Air 0 cfm Supply Fan 1200 cfm 69.3 of 115.0 / 73.5 of Outside Air 0 cfm 78.8/61.6 of 69.3 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 23,575 -363 BDP CO 395CAV036045/598AN036 32,232 921 35,000 Total Adjusted System Output 32,232 921 35,000 (Adjusted for Peak Design Conditions) Heating Coil 96.7 of TIME OF SYSTEM PEAK I Aug 2 pm I Jan 12 am i% Return Air Ducts 4 78.8161.60F 78.8 ! 61.6 of 53.6 / 52.2 of -Qs� Supply Fan 1200 cfm Cooling Coil h Return Air Ducts 4 3.1 By EnergySoft User Number. 2366 Job Number. 4019 Supply Air Ducts 96.0 of ROOMS 70.0 of Supply Air Ducts 54.4 / 52.5 of 38.4% R.H. ROOMS 78.0 / 61.3 of of 23 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE WOODARD-CASILLI RESIDENCE 4/1/2004 SYSTEM NAME FLOOR AREA Guest Suite 626 hI�IwICCt�1�IP_ ^uCr�c w.�w.�w... Number of Systems 1 Heating System Output per System 35,000 Total Output (Btuh) 35,000 Output (Btuh/sgft) 55.9 Cooling System Output per System 40,000 Total Output (Btuh) 40,000 Total Output (Tons) 3.3 Total Output (Btuh/sgft) 63.9 Total Output (sgft/Ton) 187.8 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sgft) 1.92 Airflow (cfm/Ton) 360.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above JEATING SYSTE 26.0 of Outside Air 0 cfm 69.5 of 15.0 / 73.5 of Outside Air 0 cfm 78.6/61.6 of at ARI conditions 69.5 of 69.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK HTG. PEAK CFM Sensible ]COIL Latent CFM Sensible 16,648 -186 15 260 BDP CO 395CAV036045/598AN036 32,033 1,086 35,000 Total Adjusted System Output32,033 1,086 35,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 72J��� Supply Fan Heating Coil 1200 cfm 96.9 of h Return Air Ducts 4 78.6/61.6"F 78.6/61.60F 53.5/52.1 OF 0 Supply Fan 1200 drn Cooling Coil h Return Air Ducts `S 3.1 By EnergySoft User Number: 2366 Job Number. 4019 SupplY Air Ducts 96.3 of ROOMS 70.0 of Supply Air Ducts 54.1 / 52.4 of 38.5% R.H. ROOMS 78.0 / 61.4 OF of 23