Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
04-5348 (SFD)
a a ° �a� �• 06 2004 � LA QUINTA • ulcv 3 ' CE DEPT. BUILDING & SAFETY DEPARTMENT c P.O. Box 1504 (760).7 77-7012 OF.9 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT Application Number . . . . . 04-00005348 Date 7/02/04 Property Address . . . . . 53395 VIA STRADA APN: 772-540-.033- - - Application description .. DWELLING - SINGLE FAMILY DETACHED Property Zoning . . . . . . . LOW DENSITY RESIDENTIAL Application valuation.. .'. 405113 Owner Contractor DECKER GARY L & JANE J JACOBS HOMES INC, PETER ..43 6.11. OLD. HARBOR. -DR P:: 0. BOX 6.92 - BERMUDA DUNES CA 92201-0 LA QUINTA CA 92253 (760) 777-9.921 WCC:. EXEMPT ' WC.: EXEMPT -.04/3'0/05 CSLB: 799499 04./30/05 CCC:' B.'. - -------- - - - - - ---- ----=--= Structure Information ----=-------------==------ Construction Type . . . . . TYPE V = NON RATED Occupancy Type . . . ... . DWELLG/LODGING/LONG <=10 Flood Zone .. NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION •2001 # BEDROOMS ..3.00 FIRE SPRINKLERS NO GARAGE SQ FTG 1194..00 PATIO.SQ FTG 651.00 NUMBER.OF UNITS 1:00 . . FIRST FLOOR -SQ FTG. 4617.00 Permit Permit ----------------------- BUILDING PERMIT. ------------- Additional des.c ' Permit.Fee 1710.50 Plan Check Fee 111.83 Issue Date Valuation., 4051.13 Qty Unit Charge Per. Extension BASE FEE 639.50 .306.00 3.5000 ----------------------------------------------------------------------=----- THOU BLDG 100,001-500,000 1071.00 Permit ELEC-NEW RESIDENTIAL Additional desa.. . Permit Fee 215.48 Plan Check Fee 53.87 Issue Date : Valuation . . . 0 .Qty .Unit Charge Per Extension P.O. BOX 1504 78-495 CALLE TAMPita) LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT Application Number. Applicant: Applicant's Mailing Address: Architect or Engineer. VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777.7153 Date: Architect or Engineer's Address: Lic. No.. BUILDING PERMIT DECLARATIONS UCE14SED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapteer�9 (com wnckV with Section 7000) of Division 3 of One Business and. Professionals Code. and my, Lioense is • force and effect. f/ 7 9 License G^�ass License No. Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5. Business and Professions Code: Any city or county that requires a permit to construct, after. kmprove, demolish, or repair any strucMe, prior to its Issuance, also requires the applicant for the permit to file a signed statement that he or she Is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any appicard for a permit subjects the appticart to a dW penalty of not more than five hundred dollars ($500).r U 1. as owner of the property, or my employees with wages as their sole compensation, will do the work, and 9me stnncture Is not Intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or Improves thereon, and who does the work himself or herself or through his or her own employees. provided that the irnproveinents are not intended or offered for sale. If, however. the building or it provement Is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not bund or improve for the purpose of sale.). U 1. as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sac. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who bunds or khpmves thereon., and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 91 am exempt under Sec. BA P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION 1. hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 37'00 of the Labor Code, for the,parfarrhhance of the work for which this permit is issued. _ I have and will maintain workers' compensation Insurance. as required by Section 3700 of the Labor Code. for the performance of the work forwficlm.Bhis Permit is issued. My workers' compensation insurance carrier and policy number are: Cartier Policy Number I ceatify that, In the performance of the work for which this permit Is issued, I shall not employ any Pin In any manner so as to become subject lo the workers' compensation laws of California, and agree that, If I should become subject b the workers' compensation provisions of Section forthwith comply with those 3700 of the Labor Code, I shall Dater ���'� Appicamt WARNING: FAILURE? TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL. AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN . SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY 1 hereby affirm under it I /� ury that there is a constriction lending agency for the Performance of the work for which this permit is issued (Sec. 3097. Civ. C.). Lendees Name - �.�! Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the concretions and restrictions set forth on this eppication. 1. Each Person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any penmlt Issued as a result of this application, the owner. and the applicant each agrees to. and shall, defend. Indemnify and hold hhannless the City of La Quinta. its officers, agents and employees for any act or omission related to Or work being performed under or following issuance of this pencil 2. Any Permit Issued as a result of this application !becomes null and vold lt wok is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above Inforn4ion Is correct. I construction. and hereby authorize. agree to y with an city and county oedinarces and state haws relating b bundling representatives of this county to the boned property for inspection purposes. Date r /G Signature (Applicant or Agent): Page 2 Application Number . . . . . 04-00005348 Date 7/02/04 Qty Unit Charge Per Extension BASE FEE 15.00 4617.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 161.60 1194.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 23.88 1.00 ---------------------------------------------------------------------------- 15.0000 EA ELEC TEMPORARY POWER -POLE 15.00 Permit . . . . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date. Valuation . . . . 0 Qty Unit Charge Per Extension --------------- ----- BASE FEE 15.00 Permit . ------ ... . . . --------------------------------------- MECHANICAL ----------- .Additional desc . . Permit Fee . . . . 132.50 Plan Check Fee 33.13 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 4..00 9.0000 EA MECH FURNACE <=100K 36.00 4.00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 6.00 6.5000 EA MECH VENT FAN 39.00 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . . . . PLUMBING Additional desc Permit Fee . . . . 195.75 Plan Check Fee 48.94 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 19.00 6.0000 EA PLB FIXTURE 114.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 13.00 .7500 EA PLB GAS PIPE >=5 9,75 1.00 ---------------------------------------------------------------------------- 15.0000 EA PLB GAS METER 15.00 Special Notes and Comments SFD - 4617 SQFT. PERMIT DOES NOT INCLUDE Page 3 Application Number ---------------------------------------------------------------------------- . . . . . 04-00005348 Date 7/02/04 Special Notes and Comments BLOCK WALL, POOL OR DRIVEWAY APPROACH. $1,000.00 PLAN CHECK FEE APPLIED TO PLAN REVIEW FEE. -------------------------- Other Fees . . . -------------------------------------------------- . . . . . ART IN PUBLIC PLACES -RES 512.78 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 111.18 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES .502.00 STRONG MOTION (SMI) .- RES 40.51 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary ----------------- Charged Paid Credited Due Permit Fee Total ---------- 2269.23 ------------------------------ .00 .00 2269.23 Plan Check Total 247.77 .00 .00 247.77 Other Fee Total 3069.47 .00 .00 3069.47 Grand Total 5586.47 .00 .00 5586.47 NN- 3i - Building S „ Address Owner /7- i �.0. BOX 1504 1� 78-495 CALLE TAMPICO �.S U! 4 S7TGW4 LA QUINTA, CALIFORNIA 92253 Mailing f n Address , U /� ,S%j City Zip Tel. Z4 40(.4 2 2 3 �flv - Flo Contractor Address SQ�1G p I Tel. State Lic. I city & Classif. Lic. # Arch., Engr., Designer Address Tel. City (Zip (State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is In full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, Improve, demolish, or repair any structure, prior to'Its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code. or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). I-] I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I 1 I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) I-1 1 am exempt under Sec. B. & P.C. for this reason Dale Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company n Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of th@ work. for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Ihereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives sof this city to enter the above- mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip APPLICATION ONLY BUILDING: TYPE'�CONST.\ OCC. GRP. 7;P2- A.P. Number ^ S -Yo —V 33 A Legal Description La 7 2 Project Description Size Stories 1 � � �>' � J/iilL•ir/AL3 No. Dw. Units ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. �— Plan Chk. Bal. Const. Mech. Electrical Plumbing C S.M.I. Ir V _ I1 11)i1 Grading 111 —')]I10 Driveway Enc. 1 14 N 9�� �� I � PI Infrastructure nx iH TOTAL REMARKS 0,11 9 ZONE: Minimum Setba FINAL DATE Issued by: Validated by: Validation: BY: Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line INSPECTOR Date Permit WHITE = FINANCE YELLOW = APPLICANT PINK = BUILDING DIVISION C achella Valley Unified School District P.O. Box 847, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 Project Name: Owner's Name: M/M Decker Project Address: Project Description: _ APN: 775-540-033 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: OATF., RF.CF.IPT- CHECK H• INITIALS' CERTIFICATE OF COMPLIANCE (California Education Code 17620) 53-395 Via Strada La Quinta, CA 1 SFD Tract #: Type of Development: Residential XX Total Square Feet of Building Are Certification of Applicant/Owners: The person signing cc under penalty of perjury and further represents that he/she is Dated: July 2, 2004 Signature: Date Phone No. Lot #'s: July 2, 2004 Commercial Industrial 4,617 sq. ft. tWS bove information is correct and makes this statement gn on behalf of the owner/developer. *************************************4********************************* SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Note: Number of Sq.Ft. 4,617 Amount per Sq.Ft. $ 2.68 Amount Collected $12,373.56 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: Elvira Mattson, Office Technician Signature: Not Subject to Fee NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. MV:c/mydocs/devfees/certificate of compliance form tables.doc 1/16/03 T JP,.N .1; 2004 09:57 FR FIRST AMERICAN TITLE 0 568 5954 TO 97779923 WHEN RECORDED MAIL TO: SAM AS D)BM MAIL TAX STATEMENT TO: and Jane J.IDecker ;X•I.-] DOC N 2003-060401 etiasrlvsa 45:004 Fae:z=.ea PaOs 1 of S Doe T Tau Paid Raoardad iw Ofrisrsl Raoorda County of Riverside Oary L. ors* Assassor, County Clark i R000rdor 1111111111 IN I I 11111 --Q611 Older—h- D—te M : U Moi COL MA rca10 MocoR ew WG Bermuda Dunes, CA 92201 6554 --CP 2 • R L ee.r usi. p►vMo ,K,q p�,i DOCUMENT TRANSFER TAX S 584.10 aY Computed on the considaation or value of property conveyed, OR MA Computed on the consideration or value less liens or enoumbrames (� remAining at the time of sale. N5-0- �-off TIM MM»xGM S�gnan�ro oiDee araat of Aged ddermfn* rax -- Fiffi Naau GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company ("Grantor"), hereby GRANT(S) to g Decker and Jane J. Decker ** ("Grantee"), the real property located in the City of La Quints, County of Riverside, State of California, described as: ao Husband and Wife as Joint Tenants nights of Survivorship See Legal Description attached hereto and incorporated herein as Exhibit "A". SUBJECT TO all matters of record including, without limitation, the covenants and agreements dewtibod in Exlu'bit "A" attached hereto. Dated: _January 13. 2003 ND LA QUINTA PARTNERS, LLC, a Delaware limited liability company By: Nationwide Realty Investors, Ltd., an Ohio limited liability company its managing member By: W0 -P4 / 4.A,�� Wiae A EWs- h 9.74w --,or Pfesident'and A t thov; z c,6 46" Chief opeffefinc0– Description: Riverside,CA Document-Year.DociD 2003.69491 Page: 1 of 6 Or6v.• 00-01-13-2004 10-15-22 AM Comment: 249 JAN 13 2004 09:57 FR FIRST AMERICAN TITLE 0 568 5954 TO 97779923 CALIFORNIA ALL-PURPOSE ACKNOWLEDOMENT state of Califomi County of On I --?0Z , before me, at'^AW 4,( /4'��i/YY&M ply NAM trd Tial 61 aft- I•A.. -js- Doe. Nwry pum, personalty appeared G Ar Nunwg dSW4"(1) D personally known to me U proved to me on the basis of satisfactory evidence rAC23h. CAlMDt1N1! A. HA MMOM "° JR3ver>ids t,a►nty PW@ Nuwy 9" AMY* to be the person(s) whose name(s) Islare subscribed to the within Instrument and acknowledged to me that he/she/they executed the same In his/her/their authorized capacity(les), and that by his/her/their signature(s) on the Instrument the person(s), or the entity n behalf of which the person(s) acted, meted the (pstrument. , and OPTIONAL though the Inrormallon below Is nol required by Nw, it mer prove veluebre to peraone MOV on the document and could prevent haudulam remover end neelr8chmenl of IN$ krm ro another document. Description of Attached Document Title or Type of Document: Document Data: Number of Pages: Signer(s) Other Than Named Above: Capaclty(ies) Claimed by Signer Signer's Name: l Individual top or ihumo here CI Corporate Officer —T1tie(e): J Partner — L' limited I I General I i Attorney In Fact U Truetee t.) Guardian or Conservator LJ Other: Slgner Is Repreeenting: e,tMe NI.q�YWmr/�mYM•OLle o�Eaio Av,n.O.00.?tOG •GMnoM. CAl17�itM!•wrmbYwWON had N. AaOw: 00T."..6I~&- 7! 111{UlDilll�lll�� milli I I ei �e�.aH Description: Riverside, CA Document-Year.DoclD 2003.69491 Page: 2 of 6 Order: 00-01-13-200410-15-22 AM Comment. 249 P.07 JAN 13 2004 09:57 FR FIRST AMERICAN TITLE 0 56B 5954 TO 97779923 P.08 Under the provisions of Government Code 27361.7,1 certify under the penalty Of perjury that the notary seal on the document to which this statement is attached reads as follows: Name otNotary: �mmc Commission N: County where bond is filed: t v ql Date Commission Expires: Place of Execution: ( — Date,,: Signature; 11111�I1N �"-�:�'- Description: Riverside, CA Document-Year.DoclD 2003.69491 Page. 3 of 6 Order. 00-01-13-2004 10-15-22 AM Comment: 249 J.AN 13 2004 09:57 FR FIRST AMERICAN TITLE 0.566 5954 TO -97779923 P.09 ' T71�B11T "A� f I Parcel No I _ 4 Lot — w _ (the "Lof of Amended TactNo "29694-e 0�1 u chows on a Subdivision Map (the "Map") recorded on bairenfisr.=12 ' 2002 •; in Book 327 , pagn S6 to 86 - inchtsive, of Maps, is the Office of the Ithwsiide Ceunry Recorder. EXCEP ENG AND RESERVING T MPMROM TO t3RANTOR µsad hs`aucceaeors, "Sim invitees, lioenseea end employees; fog . antti th dight to gr end ttaaaRr al or a portion of the same, all easements and rights for access, ingress, egteae, encroachment;:` maintenance, drainage, support, and for other purposes over the Association Maintenance Areas and other portion of the Lot, reserved to Grantor in the following instruments: 1. The Amended and Restated Declaration of Covenants, Conditions and Restrictions and Reservation of Easements for The l frdeaway Owners Association (as amended or zupplemented, the ''Deebration' ), recorded on December 13 , 2002, as 1n3bUment No. 2002-745939 . of Official Records of Riverside County, California (the "Official Records'); Fmnm RBSiaRviNG Ti amolt+>% 46 dja it to alar the Lot tbr` a tam of twelvc (12) emontht following the recordation of this Grant Deed, to 6*1ete and re* iffy, improvements or landscaping located thereon u deterntiaed neces y by Otintot; in its cob discretion, in order to comply with�fegniremem O Y� of tho Final Tract Map; the ' grading of said Tract sadfor itis mpliance with tht coquirctneate of ipplicable goval agencies. Such entry by Grazittor shall be preceded by reasonable notice to Grantee beibre entry. If this reservation of right of eatry isnot compiled with by Grow% Gaantor n* enforce this right of entry in a court of law. Grantee shall be reapoau'ble for all damAges arising out of said breach including attorneys' fees sad court costs. This reservation of right of entry shall automatically expire twelve (12) months ftam the reoor4tion of this Grant Deed. ParceLbto-2; Nonexclusive easements for access, ingress, egress, drainage, maintenanceq repairs and for other purposes, all at, described in the Declaration. SUBJECT TO: 1. Nondelinquent gederal, gWcial and supplemental real property taxes and assessments. 'Im, 0511111 WAN { Description: Riverside, CA Document-Year.poc/D 2003,69491 Page: 4 of 6 Order. 00-09-13-200410-15-22 AM Comment: 249 JAN 13 2004 09:58 FR FIRST AMERICAN TITLE 0 568 5954 TO 97779923 2. w All other " ' oovenaats,' conditions, rertiictioss "neseivatlons, enemenn, tights and righta.of--way of record ineludiag, lin>jtadbi the Declaration and the Map for Tran No 29894-2 #:r�..� :.-.ark Grantee. by acceptance ittd recordation of Chia C?cant Deed; hereby (a) meepts and approves all of the foregoing in thii Grist Deed, (b) Ointi to Oraddr utd The Hideaway Owners Association such power=and'rightit "ae itre jit fiWie" the DgWi6on ;end (c) ccepts, covenants and agrees to be bound by and as,ume peticuum of ell •of the applicable provisions AM requirements set forth in the Declaration; including Section ding the procedure for resolving disputes with Gmtor, and the notice; which pie Q;tm and requirements aro acknowledged to be reasonable and Incorpoiated herein by this reference thereto. This grant is conditioned upon the pe&rmanee of such provisions and requirements as we to be performed by Grantee under the Declaration, The restrictions on use and occupancy of the Lot aro set forth in the Declaration to which this Grant Deed is specifivally and expressly trade subject. GRANTEE HEREBY ACCEPTS AND APPROVES THE POREGOING, granting unto Grantor and The Hideaway Owners Association such powers ad rights which are set fbrth in the Declaration fined abovq on k ol== 2002.• L erl e a J..4101mr.:. i STATE OF CAlr%6maa,SL ) COUNTY OF ) On %7 2002, bdfbre me, the undersigned, a notary public in and for said Ste* personally appeared Gnnr L. je&te _ personally known to me (or proved to me on the basis of satisfactory evidence) to be the persons) whose name(,) is/are subscribed to the within instrument and acknowledged to me that he/shm6y executed the same in his/her/their authorized capm4ty(ies), and that by hisAwAhek signature(,) on the instrument the person(s), or the entity upon behalf of which the person(,) acted, executed the instnaaent. VirMSS MY HAND AND OFFICIAL SEAL. •^ ISLAfA,. t' tu►tt+arrrtsa Signature _ (mo) `co�.ntalon t t x IVe"tcsy r,P ' ufty o Court» a6pte,Mov1,OAV06 INUM111N�l ll Uqq „ s1 . 2 Doscrlptlon: Rlverslde,CA Document-Year.Doc/D 2003.69491 Page: 5 of 6 Order. 00.01-13.2004 10.15.22 AM Comm6nt: 249 P.10 JAN 1.3 2004 09:58 FR FIRST AMERICAN TITLE 0 568 5954 TO 97779923 OiuFo A AL1,4PUMOSE ACKMOWLIDOM ' State d cdoff" . county.0, Pkwe(Sx 64 on % ;Ll g' o25 before me, � t.i Y. c•• a • Mo�C Due personalty appeared 0 pwsonapy known to an 0 d to me on ft basis d sattt:bAn •M� Ar ff014, •'•alio- CsVemb Ra. •dldaCor,rer r11CNhn t�iwt�lf 1t.1� to,bs the, peysort(y who" neme(e we „eubsemed to the withirf struma and adutawkdped b me "wiled RN same In a ecMy(r cepes), end that by-" 'stprwkn(s) on the trlaiwwd the person(s), a the wW upon melt of which the petsor►(s) setad, exaaAed IM M mtent AWIDW Pr�pgM WITNESS end erb otgdd seal. eta cou W& -- r• �ftftMDtt,2==m OP 70MAL rhw*1aw"a wDow MMMOUMbyICKk"1Pow whabbbM—Nrfr"DPMfaft NaroM&ofI" rim&t6w ie wo ) srb Mrrclmww Or #* lwm fo awf t d0 vff Ut! Description of AttacheddDDoctmnt Tpb or Type of Document: ``, ra ,1 may` • � e C( Document Dote: 1 & J Num1wr of Pages:.__ signer(s) Onhor Than Named Above: Capacitypes) Chimed by 51911er Sipnar's Herne: U 6lddridual d Mf O "o' t] Corporats0ltiar--Title(s): 0 Pamw —0 Limited 0 Goneral 0 Attorneyan-Fact 0 Trustee Q Ouardien of conservator 0 Other. Sloner Is Fiepreeenting oaM•w•rrwrrr�waaawa•q••asrAw./.a�i�o•• ylG•aiUir�r•�4�MWW•M POM NLSw MIA Mloflf•,40WPM4. imlw1aWsalN�l e1i or e aN'e611 -r Description: Rivemide,CA Document-Year.DoCID 2003.69491 Page: 6 of 0 Orden 00-01-13-200410-15-22 AM Comment: 249 TITLE 24 REPORT Title 24 Report for: Decker Residence Hideaway Lot 249 La Quinta, CA 92253 Project Designer: South Coast Architects 13 Corporate Plaza. Suite 210 Newport Beach, CA 92660 (949) 720-7022 Report Prepared By: CJ Mcfadden " BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855,5 CITY OF LA QUANTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION Job Number: DATE 61Z1`DY By /�4. 0 - Date: 6/2/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is ;I authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnerovPro 3.1 By EnerovSoft Job Number: User Number. 3665 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R •Decker Residence 6/2/2004 Project Title Date Hideaway Lot 249 La Quinta Project Address Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Check/ Date Documentation Author Telephone Computer Performance 15 Field Check/ Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 4,617 ft2 Average Ceiling Height: 12.9 ft Total Conditioned Slab Area: 4-617 ft2 0 • Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (East) 90 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component R-38 Roof (R.38.2xl4.16) W-1 Wall (W.21.2x6.16) Slab On Grade Slab On Grade Solid Wood Door W-2 Wall (W.21.2x6.16) FENESTRATION Frame Type Const. Assembly U -Value Location/Comments (attic, garage, typical, etc.) Wood 0.028 Exterior Roof Wood 0.057 Exterior Wall n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Wood 0.387 Exterior Door Wood 0.057 Exterior Wall X❑ ❑ Q Left Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Skylight 6.8 0.80 0.43 None ❑ X❑ ❑ Q Left (South) 10.0 0.55 0.30 Bug Screen ❑ X❑ ❑ X❑ Left (South) 88.8 0.40 0.35 Bug Screen ❑ X❑ ❑ Q Left (South) 96.0 0.99 0.60 Bug Screen ❑ x❑ ❑ X❑ Rear (West) 48.0 0.55 0.53 Bug Screen ❑ X❑ ❑ X❑ Rear (West) 151.6 0.40 0.35 Bug Screen ❑ X❑ ❑ X❑ Right (North) 72.0 0.99 0.60 Bug Screen ❑ X❑ ❑ X❑ Right (North) 64.0 0.52 0.36 Bug Screen ❑ X❑ ❑ X❑ Right (North) 66.0 0.40 0.35 Bug Screen ❑ X❑ ❑ X❑ Front (East) 24.4 0.40 0.35 Bug Screen ❑ X❑ ❑ X❑ Front (East) 96.0 0.99 0.60 Bug Screen ❑ X❑ ❑ X❑ Front (East) 10.0 0.55 0.30 Bug Screen ❑ X❑ ❑X❑ Run Initiation Time: 06102/04 09:54.43 Run Code: 1086195283 Ener Pro 3.1 By Ener Soft User Number: 3665 Job Number. Page: 3 of 33 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R •Decker Residence 6/2/2004 Project Title Date Hideaway Lot 249 La Quinta Project Address Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Check/ Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 4,617 fl? Average Ceiling Height: 12.9 ft Total Conditioned Slab Area: 4,617 fl? • Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (East) 90 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component FENESTRATION Const. Frame Assembly Location/Comments Tvpe U -Value (attic, garage, typical, etc. Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Rear (West) 200.0 0.52 0.36 Bug Screen X❑ ❑ ❑ X❑ Rear (West) 20.0 0.55 0.30 Bug Screen ❑ X❑ ❑ X❑ Right (North) 36.4 0.55 0.30 Bug Screen ❑ x❑ ❑ X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 0 E El El ❑❑ El El Run Initiation Time: 06/02/04 09:54:43 Run Code: 1086195283 Ener Pro 3.1 B Ener Soft User Number: 3665 Job Number. Pa e:4 of 33 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R •Decker Residence 6/2/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Flimarp 80% AFUE Ducts in Attic 42 Setback HVAC -1 (Sleeping) Central Euulace 80% AFUE Ducts in Attic 49 Sethark HVAC -2a A 2h (Living) Central Furnnre 80% AFUE Ducts in Attic 42 Setback HVAC -3 (Sleeping) • Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner Split Air Conditioner Split Air Conditioner WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value Standard Gas 50 gal or Less Small Gas Recireffemp 2. 40,000 50 0.52 n/a 12 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: South Coast Architects Address: 13 Corporate Plaza. Suite 210 Newport Beach, CA 92660 Telephone: (949) 720-7022 Lic. #: (signature) Enforcement Agency Name: Title/Firm: • Address: Telephone EneravPl ro 3.1 By EneravSo User Number: 3665 (date) Name: CJ Mcfadden Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: (760) 346-0855 Gk 4/.2/04 (signature) (date) Job Number. of 33 Certificate of Compliance: Residential (Addendum) CF -1 R Awk Decker Residence 6/2/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC -1 (Sleeping)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -1 (Sleeping)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 325 sqft Tile in Mortar Interior Mass, 0.75' thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 325 sqft Exposed Slab Floor, 4.00" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 730 sqft Covered Slab Floor, 4.00" thick at Master Suite The HVAC System "HVAC -2a & 2b (Living)" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -2a & 2b (Living)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2537 sqft Tile in Mortar Interior Mass, 0.75' thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2537 sqft Exposed Slab Floor, 4.00" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 282 sqft Covered Slab Floor, 4.00" thick at Living Area The HVAC System "HVAC -3 (Sleeping)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -3 (Sleeping)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC -1 (Sleeping)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2a & 2b (Living)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3 (Sleeping)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. I EneravPro 3.1 By EneravSoft User Number: 3665 Job Number. Pane:6 of 33 1 Certificate of Compliance: Residential (Addendum) CF -1 R •Decker Residence 6/2/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )asea on ine aaequacy or ine special JustirIcation ana aocumemation sunmittea. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 543 sqft Tile in Mortar Interior Mass, 0.75' thick at Guest Suites HIGH MASS Design(see C -2R) - Verify Thermal Mass: 543 sqft Exposed Slab Floor, 4.00" thick at Guest Suites HIGH MASS Design(see C -2R) - Verify Thermal Mass: 200 sqft Covered Slab Floor, 4.00" thick at Guest Suites HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field • • I EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Pam:7 of 33 1 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an • asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. is DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ❑X '§ 150(a): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturers labeled R -Value. §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ❑X not apply to exterior mass walls). E]'§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. X§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door : b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ❑X § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. F § 150(j): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:8 of 33 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an • asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • 0 DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A If not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) a'§150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. ' 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between fitter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. a§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. FV §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumehs/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number. 3665 Job Number. Page:9 of 33 Computer Method Summary (Part 1 of 3) C -2R pecker Residence 6/2/2004 roject Title Date Hideaway lI oto 1 a Qijinta Project Address Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Documentation Author Telephone Plan Check/Date Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.33 3.54 -0.21 Space Cooling 34.69 32.27 2.42 Domestic Hot Water 6.17 8.32 -2.15 Totals 44.19 44.13 0.06 Percent better than Standard: 0.1% BUILDING COMPLIES Total Conditioned Floor Area: 4,617 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Type: Single Fam Detached Building Front Orientation: (East) 90 deg Total Fenestration Area: 21.4% Number of Dwelling Units: 1.00 Total Conditioned Volume: 59,607 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 4,617 ft 2 BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt Ronf 1,952 0.028 345 -/all 48 0.057 _�_ _9Q nor 39 0.387 go go Wall 160 0.057 ga go nnor 20 0.387 90 90 Wall 231 0.057 180 90 wall 38 0.057 180 9.Q Wall 445 0.057 270 _90 Roof 743 0.028 345 —0 Wall 134 0.057 _ 0 _90 Wall 60 0.057 —0 _9p Wall 201 0.057 90 g0_ Wall 76 0.057 _90 —90 Wall 212 0.057 180 90 Wall 36 0.057 270 90 4) Zone Type Sleeping Living Sleeping Thermostat Vent Type Hgt. Area SIAAping4tat _� n/a LivingStat n/a Sleeping, tat n/a Solar Gains Y / N Form 3 Reference Location / Comments EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 10 of 33 Computer Method Summary (Part 2 of 3) C -2R Decker Residence 6/2/2004 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments J- Skylight Rig11t (North) 34 0 800 0.43 345 0 Bristolite Skylite 7one 1 2 Window Left (South) 10.06 0.550 0.30 180 90 Fleetwood Glazing (Lo/E) Zone 1 3 Window Left (South) 10.0• 0.400 0.35 180 90 Fleetwood Glazing (Lo/E) Zone 1 4 Window Left (South) 10.0 • 0.400 0.35 180 90 Fleetwood Glazing (Lo/E) Zone 1 5 Window Left (South) 24.0 • 0.990 0.60 180 90 Default Single NonMtl Tinted Zone 1 6 Window Rear (West) 48.0 ' 0.550 0.53 270 90 Default Double NonMtl Tinted Zone 1 7 Window Rear (West) 39.0 0.400 0.35 270 90 Fleetwood Glazing (L9/E) Zone 1 8 Skylight Right (North) 3.4 0.800 0.43 345 0 Bristolite Skylite Zone 2a & 2b 9 Window Right (North) 24.0 14 0.990 0.60 0 90 Default Single NonMtl Tinted Zone 2a & 2b 1Q Window Right (North) 64.0 • 0.520 0.36 0 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 11 Window Right (North) 15.0 • 0.400 0.35 0 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 12 Window Right (North) 15.0 • 0.400 0.35 0 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b -ta Window Rightt(North) 15.0' 0.400 0.35 90 Fleetwood GlaziagjLo/E) Zone 2a & 2b 14 Window Right (North) 15.0 • 0.400 0.35 0 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 15 Window Right (North) 6.0 • 0.400 0.35 0 90 Fleetwood Glazing ME) Zone 2a & 2b 16 Window Right (North) 48.0 • 0.990 0.60 0 90 Default Single NonMtl Tinted Zone 2a & 2b 17 Window Front (East) 3.8 • 0.400 0.35 90 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 18 Window Front (East) 48.0 • 0.990 0.60 90 90 Default Single NonMtl Tinted Zone 2a & 2b -1 Window Front (East) 3.8 • 0.400 0.35 90 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 20 Window Front (East) 10.0 • 0.550 0.30 90 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 21 Window Front (East) 3.0 • 0.400 0.35 90 90 Fleetwood Glazing ME) Zone 2a & 2b 22 Window Left (South) 24.0 • 0.990 0.60 180 90 Default Single NonMtl Tinted Zone 2a & 2b 23 Window Left (South) 15.0 • 0.400 0.35 180 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 24 Window Left (South) 15.0 ' 0.400 0.35 180 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 25 Window Left (South) 15.0 • 0.400 0.35 180 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 26 Window Left (South) 3.8 • 0.400 0.35 180 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b Window Left (South) 10.0 0.400 0.35 180 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 1027 28 Window Left (South) 10.0 0.400 0.35 180 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 29 Window Rear (West) 200.0 • 0.520 0.36 270 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b INTERIOR AND EXTERIOR SHADING Window Overhanq Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 _ 7 Bug Screen 0.76 8 None 1.00 9 Bug Screen 0.76 _ _ 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 _ 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 _ 26 Bug Screen 0.76 27 Bug Screen 0.76 _ 28 Bug Screen 0.76 29 Bug Screen 0.76 10.0 20.0 10.0 0.1 10.0 10.0 EneravPro 3.1 By EneravSoft User Number: 3665 Job Number. Page: 11 of 33 Computer Method Summary (Part 2 of 3) C -2R Decker Residence 6/2/2004 • Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments _30 Window Rear (West) 40. 0 400 0.35 270 90 Fleetwood Glazing (I n/E) Zone 2a & 2h 31 Window Rear (West) 4.0. 0.400 0.35 270 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 32 Window Rear (West) 4.0. 0.400 0.35 270 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 33 Window Rear (West) 4.0 , 0.400 0.35 270 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 34 Window Rear (West) 10.0. 0.550 0.30 270 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 35 Window Rear (West) 10.0 • 0.400 0.35 270 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 36 Window Rear Mest) 10.0 ' 0.550 0.30 270 90 Fleetwood Glazing ( o/E) Zone 2a & 2b 37 Window Rear (West) 26.3 - 0.400 0.35 270 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 38 Window Rear est) 28.0 .400 0.35 270 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 29 Window Rear (West. 26.3 • 0.400 0.35 270 - 0 Fleetwood Glazing (Lo/E) Zone 2a & 2b 40 Window Rear (Vilest) 6.0 • 0.400 0.35 270 90 Fleetwood Glazing (Lo/E) Zone 2a & 2b 41 Window Right (North) 3.8 • 0.550 0.30 0 90 Fleetwood Glazing (Lo/E) Zone 3 A2 Window Right (North) 3.8 • _0.550 0.30 a 90 Fleetwood Glazing() o/E) Zone 3 43 Window Right (North) 3.8 • 0.550 0.30 0 90 Fleetwood Glazing (Lo/E) Zone 3 44 Window Right (North) 25.0. 0.550 0.30 0 90 Fleetwood Glazing (Lo/E) Zone 3 45 Window Front (East) 10.0• 0.400 0.35 90 90 Fleetwood Glazing (Lo/E) Zone 3 46 Window Front (East) 48.0' 0.990 0.60 90 90 Default Single NonMtl Tinted Zone 3 47 Window Front (East) 3.8 • 0.400 0.35 90 90 Fleetwood Glazinq (Lo/E) Zone 3 Window INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 - 36 Bug Screen 0.76 - 37 Bug Screen 0.76 38 Bug Screen 0.76 _ 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen _ 0.76 42 Bug Screen 0.76 43 Bug Screen _ 0.76 - 44 Bug Screen 0.76 - 45 Bug Screen 0.76 - 46 Bug Screen 0.76 - 47 Bug Screen 0.76 48 Bug Screen 0.76 - EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 12 of 33 Computer Method Summary (Part 3 of 3) C -2R leDecker Residence 6/2/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Insulation R -Val. Depth Location / Comments Slab Perimeter 17 0.76 0. _ 0 Zone 1 Slab Perimeter R7 0.76 Area Thick. Heat Slab Perimeter 2 0.76 Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Tile in Mortar _325. 0_75 24 0_67 n/a 0 Zone 1 / Interior Macs Concrete, Heavyweight 325 4_00 28 0_98 n/a 0 Zone 1 / Slab on Grade Concrete, Heavyweight 730 4.00 28 0.98 n/a 2Zone 1 /Slab on Grade Tile in Mortar 2.537 0_75 24 0_67 n/a 0 Zone 2a & 2b / Interior Mass Concrete Heavyweight 2,537 4.00 28 098 n/a 0 Zone 2a & 2b / Slab on Grade PERIMETER LOSSES F2 Type Length Factor Insulation R -Val. Depth Location / Comments Slab Perimeter 17 0.76 0. _ 0 Zone 1 Slab Perimeter R7 0.76 0.0 0 Zone 1 Slab Perimeter _192 0.76 0.0 0 Zone 2a & 2b Slab Perimeter 2 0.76 0.0 0 Zone 2a & 2b .Stab Perimeter �$ 0.76 0.0 Zone 3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -1 (Sleeg) Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -2a & 2b (Living) Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -3 (Sleeping) •Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -1 (Slee 0nng) Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -2a & 2b (Living) Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -3 (Sleeping) WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. Standard Gas 50 gal or Less Small Gas Recirc/Temp 2 40,000 50 0.52 n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Computer Method Summary (Part 3 of 3) C -2R Decker Residence 6/2/2004 • Project Title Date THERMAL MASS FOR HIGH MASS DESIGN PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Deptl Slab Perimeter 20 0.76 0.0 0 Location / Comments HVAC SYSTEMS Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete. Heavyweight 282 4.00 —2$. 0.98 n/a 2Zone 2a & 2b /Slab on GradL Tile in Mortar 543 0_75 24 0_67 n/a 0 Zone 3 / Interior Mass Concrete, Heavyweight 543 4.00 _28 0.98 n/a 0 Zone 3 / Slab on Grade Concrete, Heavyweight 200 4_00 28 0_98 n/a 2 Zone 3 / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Deptl Slab Perimeter 20 0.76 0.0 0 Location / Comments HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments •Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments WATER HEATING SYSTEMS - Rated l Tank Energy Fact? 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 06102104 09:54:43 Run Code: 1086195283 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 14 of 33 Computer Method Summary (Addendum) C -2R .Decker Residence 6/2/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field E 41 The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC -1 (Sleeping)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -1 (Sleeping)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 325 sqft Tile in Mortar Interior Mass, 0.75' thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 325 sqft Exposed Slab Floor, 4.00" thick at Master Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 730 sqft Covered Slab Floor, 4.00" thick at Master Suite The HVAC System "HVAC -2a & 2b (Living)' must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -2a & 2b (Living)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2537 sqft Tile in Mortar Interior Mass, 0.75" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2537 sqft Exposed Slab Floor, 4.00" thick at Living Area HIGH MASS Design(see C -2R) - Verify Thermal Mass: 282 sqft Covered Slab Floor, 4.00" thick at Living Area The HVAC System "HVAC -3 (Sleeping)' must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -3 (Sleeping)' includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. plan Field The HVAC System "HVAC -1 (Sleeping)' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2a & 2b (Living)' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3 (Sleeping)' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. I EnerpvPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 15 of 33 1 Computer Method Summary (Addendum) C -2R Decker Residence 6/2/2004 • Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )asea on the aaequacy or ine special jusurication ana aocumemation suominea. Plan Field HIGH MASS Design(see C -2R) - Verify Thermal Mass: 543 sqft Tile in Mortar Interior Mass, 0.75" thick at Guest Suites HIGH MASS Design(see C -2R) - Verify Thermal Mass: 543 sgft Exposed Slab Floor, 4.00" thick at Guest Suites HIGH MASS Design(see C -2R) - Verify Thermal Mass: 200 sgft Covered Slab Floor, 4.00" thick at Guest Suites HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field • • I EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 16 of 33 1 3ROPOSED CONSTRUCTION ASSEMBLY ENV -3 (PROJECT NAME DATE Decker Residence 6/2/2004 COMPONENT DESCRIPTION DESCRIPTION 4MING OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 ASSEMBLY NAME yl/ -1 Wall (W.21.2x6.16) 0.31 7 0.37 8 2.60 ASSEMBLY Floor INSIDE SURFACE AIR FILM 0.680 23.11 TYPE (check one) Wall W W Ceiling Ceiling / Roof FRAMING MATERIAL Wood 0 Z FRAMING % 15 % Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) SUBTOTA R-VALU E DESCRIPTION 4MING OUTSIDE SURFACE AIR FILM 1 Stucco 2 Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.31 7 0.37 8 2.60 9 0.68 INSIDE SURFACE AIR FILM SUBTOTA R-VALU E THICK- NESS (in.) 4MING ❑ ❑ ❑ © ❑ El ❑ El El 0.170 0.875 0.010 0.375 5.500 0.625 0.465 21.000 5.445 0.562 0.562 SUBTOTA R-VALU E CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.1751 0.175 0.060 0.060 0.465 0.465 21.000 5.445 0.562 0.562 0.31 2.63 0.37 0.98 2.60 0.26 0.68 0.680 0.680 23.11 7.56 RG Ri 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0433 X 0.85 --1[ 8.46 0.20 1.69 0.06 0.35 0.02 1.06 0.29 0.31 2.63 0.37 0.98 2.60 0.26 0.68 14.81 TOTAL HC 3 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0433 X 0.85 --1[ + 0.1323 X 0.15 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE I EneravPro 3.1 By EnerovSoft User Number. 3665 Job Number: Page:17 of 33 1 E PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME Decker Residence DATE 6/2/2004 R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE ASSEMBLY NAME ASSEMBLY W-2 Wall .21.2x6.16 Floor FRAMING OUTSIDE SURFACE AIR FILM ❑ © ❑ ❑ ❑ ❑ ❑ ❑ ❑ — 1 TYPE (check one) Wall 2 Insulation, Mineral Fiber, R-21 W LU LU lL Gypsum or Plaster Board Ceiling / Roof 4 H N FRAMING MATERIAL Wood 6 22.981 7.42 7 8 =O Z FRAMING % 15 %o Framing /a INSIDE SURFACE AIR FILM TOTAL HC 2.3 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE THICK- NESS (in.) DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM ❑ © ❑ ❑ ❑ ❑ ❑ ❑ ❑ — 1 Gypsum or Plaster Board 0.625 2 Insulation, Mineral Fiber, R-21 5.500 3 Gypsum or Plaster Board 0.625 4 5 0.680 6 22.981 7.42 7 8 9 INSIDE SURFACE AIR FILM TOTAL HC R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.5621 0.562 21.000 5.445 0.562 0.562 0.37 0.98 2.60 0.26 0.68 Fr% / 100 ASSEMBLY U -VALUE 0.680 0.680 22.981 7.42 Rc Rf 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0435 X 0.85 ] 2.60 0.26 0.68 2.63 0.37 0.98 2.60 0.26 0.68 Fr% / 100 ASSEMBLY U -VALUE 7 $ TOTAL HC 2.3 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0435 X 0.85 ] + [ 0.1348 X 0.15 I 1 / Rc 1 - (Fr-/./ 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE I EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 18 of 33 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Decker Residence 6/2/2004 YSTEM NAME FLOOR AREA HVAC -1 (Sleeping) 1,055 Number of Systems I 11 Heating Svstem output per system Total Output (Btuh) Output (Btuh/sqft) Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sqft) Note: values above given at ARI conditions 1400 5I TOTAL SYSTEM LOAD COIL COOLING PEAK Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts 40o •7 Latent ,500 ,500 4.9 1400 5I TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent I CFM I Sensible 1,069 22,137 2,823 346 14,542 0 1,107 727 0 0 79 3,040 1,855 79 3,901 0 0 1,107 727 27,39 4-6779 19 897 2,000 2,000 HS26-060/G40UH60C-110 (5) 46,655 4,899 89,400 1.90 410.3 4.0 Total Adjusted System Output 46,655 4,899 89,400 (Adjusted for Peak Design Conditions) _ 0.081 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 24.0 of 67.9 of 109.3 of 109.3 of URN Supply Air Ducts Outside Air 79 cfm 108'9 OF Heating Coil Supply Fan 2000 cfm ROOMS 70.0 of 69.7 of i �% Return Air Ducts '4 (COOLING SYSTEM PSYCHROMETRICS (Airstream Temoeratures at Time of Cooling Peak) I 14.1 / 80.3 of Outside 79 cfm •178.5/64.4 °F (� 79.9 / 65.2 of. 58.3 / 56.9 of Cooling Coil Supply Fa 2000 cfm 58.3 / 56.9 of ��upply Air Ducts Fan 58.8/57.1OF 47.5% R.H. ROOMS 78.0 / 64.3 of 1% Return Air Ducts `S EnergyPro 3.1 By Energysoft User Number. 3665 Job Number. Page: 19 of 33 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE 41 Decker Residence 6/2/2004 SYSTEM NAME FLOOR AREA HVAC -2a & 2b(Living) 2,819 INumber of Svstems 1 21 Total Output (Btu Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfm/sqft) Airflow (cfmrron) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions 24.0 OF 30 Outside Air 211 cfm 69.4 OF 114.1 / 80.3 OF Outside —�� 211 cfm •178.8/65.6 °F E-�l 89,400 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 178,800 63.4 I CFM 58,500 117,000 9.8 41.5 289.1 67.0 OF COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent I CFM I Sensible 3,826 72,219 1m 1,344 54,774 0 ROOMS 3,611 2,739 0 0 21 8,049 4,175 211 10,355 0 0 3,611 2,739 87,4901 14 18 70 606 z,uuu 4,000 HS26-060/G40UH60C-110 (5) 90,780 14,648 178,800 1.42 410.3 5.3 Total Adjusted System Output 80,780 14,648 178,800 (Adjusted for Peak Design Conditions) 0.08 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am (Airstream Temperatures at Time of Heating Peak) 108.40 108.4 OF S Heating Coil o upply Air Ducts 107.7 of Supply Fan 4000 cfm ROOMS 70.0 OF Retum Air Ducts I 80.7 / 66.5 OF 11111159.7 / 58.3 OF Cooling Coil Supply Fa 4000 cfm 59.7 / 58.3 OF � Supply Air Ducts Fan 60.5 / 58.6 of 51.2% R.H. ROOMS 78.0 / 65.4 OF K Return Air Ducts 'I EnemvPro 3.1 ev Enerovsoft User Number. 3665 Job Number. Page:20 of 33 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Decker Residence 6/2/2004 SYSTEM NAME FLOOR AREA HVAC -3 (Sleeping) 743 ENGINEERING CHECKS IrSYSTEM LOAD Number of Systems 1 Heating System Output per System 54,100 Total Output (Btuh) 54,100 Output (Btuh/sgft) 72.8 Cooling System Output per System 36,000 Total Output (Btuh) 36,000 Total Output (Tons) 3.0 Total Output (Btuh/sgft) 48.5 Total Output (sgftrron) 247.7 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sgft) 1.62 Airflow (cfm/Ton) 400.0 Outside Air (%) 4.6 Outside Air (cfm/sgft) 0.07 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 1COILHTG.PEAK CFM Sensible Latent 1CFM1 Sensible 948 19,790 2,196 381 15,828 0 990 791 0 0 56 2,126 1,328 56 2,731 0 0 990 791 23 895 3,524 1 20,1411 HS26-036/G40UH36A-70X (3) 29,163 2,610 54,100 Total Adjusted System Output 28,163 2,610 54,100 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 24.0 OF 67.3 OF 109.0 °F 109.0 OF O4 S Supply Air Ducts Outside Air 56 cfm 108 4 OF Heating Coil 69.4 OF DOLING SYSTEM PSYCH 114.1 / 80.3 OF Outside Air 56 cfm • 78.8 / 64.4 ° F 3.1 Supply Fan - 1200 cfm ROOMS 70.0 OF Return Air Ducts I 80.4 / 65.2 OF 57.9 / 56.5 OF 57.9 / 56.5 OF 0 Supply Air Ducts Cooling Coil Supply Fan 58.7 / 56.7 °F 1200 cfm 47.1% R.H. ROOMS 78.0 / 64.2 OF E User Number: 3665 Return Ar Ducts Job Number. of 33 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 22 of 33 PROJECT NAME Decker Residence DATE 6/2/2004 SYSTEM NAME HVAC -1 (Sleeping) FLOOR AREA 1,055 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM I SENSIBLE Zone 1 Master Suite 1 1,069 22,137 2,823 1,069 22,137 2,823 346 14,542 PAGE TOTAL 1 1,069 22,137 2,823 346 14,542 TOTAL 1 1,069 22,137 2,823 346 14,542 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page: 22 of 33 ROOM LOAD SUMMARY PROJECT NAME Decker Residence DATE 6/2/2004 SYSTEM NAME 7 HVAC -2a & 2b(Living) FLOOR AREA 2,819 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 2a & 2b Living Area 1 3,826 72,219 10,006 3,826 72,219 10,006 1,344 54,774 . PAGE TOTAL 1 3,826 72,219 10,006 1,344 54,774 TOTAL 1 3,826 72,219 10,006 1,344 54,774 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 23 of 33 ROOM LOAD SUMMARY EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 24 of 33 PROJECT NAME Decker Residence DATE 6/2/2004 YSTEM NAME HVAC -3 (Sleeping) FLOOR AREA 743 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 3 Guest Suites 1 948 19,790 2,196 948 19,790 2,196 381 15,828 I . PAGE TOTAL 1 948 19,790 2,196 381 15,828 TOTAL 1 948 19,790 2,196 381 15,828 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 24 of 33 ROOM HEATING PEAK LOADS diProject Title Date Decker Residence 6/2/2004 Room Information Design Conditions Room Name Master suite Time of Peak Jan 12 am Floor Area 1,055 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr 4.1 1051.6 X X X X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 X X X X X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 1,355 3.4 0.8000 46.0 125 626.0 0.0566 46.0 1,631 10.0 0.5500 46.0 253 59.0 0.4000 46.0 1,086 24.0 0.9900 46.0 1,093 48.0 0.5500 46.0 1,214 erimeter = 79.0 45.5 3,594 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 10 351 Infiltration: I1.00 x 1.080 x 1 055 x 9.60 x 0.50 / 60] x 46 = 4 191 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 14,542 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 25 of 33 ROOM HEATING PEAK LOADS 7 r 'ect Title Date Decker Residence 6/2/2004 Room Information Design Conditions Room Name Living Area Time of Peak Jan 12 am Floor Area 2,819 Outdoor Dry Bulb Temperature 24°F Indoor Dry Bulb Temperature 70°F = = = = = = = = = = = = = = = = • Conduction Area U -Value AT of Btu/hr Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 37 742 Infiltration: 1.00 x 1.080 x 2 819 x 14.60 x 0.50 / 60] x ® = 17 032 chedule Air Sensible Area Ceiling Height ACH AT Fraction 01 TOTAL HOURLY HEAT LOSS FOR ROOM 54,774 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 26 of 33 2,815.6 x x x x x x X x X x x x X X x x x x X x x x X x x x X x x x x x x x x x x x X 0.0280 X X x x X x x x X X x x x x x x x x x X X X x x x x x x x x x x X x x x x x x 46.0 = = = = = = = = = = = = = = = = 3,627 3.4 0.8000 46.0 125 1669.0 0.0566 46.0 4,347 144.0 0.9900 46.0 6,558 264.0 0.5200 46.0 6,315 258.0 0.4000 46.0 4,747 59.0 0.3872 46.0 1,051 30.0 0.5500 46.0 759 19 0,0572 46.0 521 perimeter = 213.0 9,692 Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 37 742 Infiltration: 1.00 x 1.080 x 2 819 x 14.60 x 0.50 / 60] x ® = 17 032 chedule Air Sensible Area Ceiling Height ACH AT Fraction 01 TOTAL HOURLY HEAT LOSS FOR ROOM 54,774 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 26 of 33 ROOM HEATING PEAK LOADS W'ect Title Date Recker Residence 6/2/2004 Room Information Design Conditions Room Name Guest Suites Time of Peak Jan 12 am Floor Area 743 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Btu/hr Conduction IW -2 Wall (W.21.2x6.161 I i Area x x x x x x x x x x x X x x x x X x x x x x x x x x x x x x x x x x x x x x x U -Value x X X x x X x x X x X X x X X x x x x x x x x x x x x x x x x x x x x x x x x AT of = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr 743.0 0.0280 46.0 957 582.8 0.0566 46.0 1,518 36.4 0.5500 46.0 921 136.0 0.0572 46.0 358 13.8 0.4000 46.0 254 96.0 0.9900 46.0 4,372 perimeter = 88.0 45.5 4,004 nems snown wim an asiensK k-) cenoce conoucnon cnrougn an mtenor surrace io anomer room. Page Total: 12,384 Infiltration: 1 1.001 .0 x Jr Sensible x Area743 x Ceiling Height ACH 50 / 60] x AT 46 = 3444 Fraction • TOTAL HOURLY HEAT LOSS FOR ROOM 15,828 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:27 of 33 0 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Decker Residence 6/2/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Master Suite 78°F 115°F 37°F Conduction Area U -Value DETD 1 Btu/hr R-38 Roof R.38.2x14.16 Bristolite Skylite -1 Wall .21.2x6.16 Fleetwood Glazing Lo/E Fleetwood Glazing Lo/E Default Single NonMtl Tinted Default Double NonMtl Tinted X X X X X X X 56.0 = = = = = = = 1,649 37.0 101 35.6 1,262 37.0 204 37.0 873 37.0 879 1 37.01 1 977 ri 1. Design Equivalent Temperature Difference (DETD) Page Total 5 944 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Bristolite Skylight 1 (Skylight) C.'qmntWdw 2) (South) FxdGlsWdw 3 (South) FxdGlsWdw 4 (South) FmchDr (5) (South) FrnchDr 6 (West) FxdGlsWdw 7 (West) 32 0.334 107 ( 0.0 1 10.0 ( 0.0 x1 x x x x X x X x X + + + + + + + + + + 3.4 x X x x x X X X x x 152 )X ) x )X x X X )X )X )x 0.494 = = = = = = = = = 255 ( 0.0 1 10.0 32 0.334 107 ( 0.0 1 10.0 32 0.390 125 ( 0.0 1 10.0 32)x 0.390 125 ( 0.0 1 24.0 32) 0.668 513 ( 0.0 1 48.0 73) 0.590 2,067 ( 0.0 1 39.0 73) 0.390 1 109 ( ( ( Sched. Page Total 4,301 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,055 x 0.500 Watts/sgft x 3.411, Btuh/Watt = 1,800 Occupants 1.00 X 1,055 X 250 Btuh/occ. / 200 sgft/occ. = 1,319 Receptacle 1.00 x 1,055 x 1.500 Watts/sqft x 3.413 BtuhMaft = 5,401 Process 1.00 x 1055 x .. 0.000 Watts/sgft X 3.414 BtuhfWatt = 0 Infiltration: �ch� x Air Sensible x Area x Ceiling x L ACIHJ.DSl1 / 60] T _ Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,1371 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 055 x 200 Btuh/OCC. / 200 sgft/occ. = 1 055 Receptacle 1.00 x 1 055 x 0.000 Watts/sgft x 3.41 Btuh/Waft = o Process 1.00 x 1 055 x 0.000 Waftslsgft X 3.41 Btuh/Watt = o Infiltration: 1.00 x 1 4,8401 X 1 05 x 9.60 x 0.50 / 60] 0.00433 = 1 768 chedule Air Latent Area Ceiling Height ACH "-\W Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2.823 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 28 of 33 RESIDENTIAL ROOM COOLING LOAD SUMMARY is Decker Residence 6/2/2004 Project Title Date 0 • Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-38 Roof (R.38.2x14.16 Bristolite Sk lite 1 Wall .21.2x6.16 Default Single NonMtl Tinted Fleetwood Glazing Lo/E Fleetwood Glazing Lo/E Solid Wood Door Fleetwood Glazing Lo/E Area U -Value DETD1 56.0 37.0 35.6 37.0 37.0 37.0 35.6 37.0 Living Area 780F 1150F 370E Btu/hr 4,416 101 3,364 5,275 5,079 = 3 818 = 813 = 610 1. Design Equivalent Temperature Difference (DETD) Page Total 23 880 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr Bristolite Skylight 8 (Skylight) Frnrhnr (9) (North) SldGlsDr 10 (North) FxdGISWdW 11 (North) FxdGlsWdw (12) (North) FxdGlsWdw 13 (North) FxdGlsWdw 14 (North) FxdGlsWdw 15 (North) FrnchDr 16 (North) FxdGlsWdw 17 Abv. East ( 0.0 X1 X X x X X x x x X + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 3.4 x X X x X x x x X x 152 ) X )X X x X ) X x 0.494 = = = = = = = = = = 255 ( 0.0 24.0 15 0.668 240 ( 0.0 64.0 15) 0.401 385 ( 0.0 15.0 15)x 0.390 88 ( 0.0 15.0 15) 0.390 88 ( 0.0 15.0 15)X 0.390 88 ( 0.0 15.0 15) 0.390 88 ( 0.0 6.0 15)x 0.390 35 ( 0.0 48.0 1 0.668 481 (1 0.0 1 3.8 1 73) 1 0.390 108 Sched. Page Total 1 855 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 2,819 x 0.500 Watts/sgft X 3.41 Btuh/Watt = 4,811 Occupants 1.00 x 2,819 X 250 Btuh/OCC. / 200 sgft/occ. = 3,524 Receptacle 1.00 x 2,819 x 1.500 Wafts/sgft X 3.413 Btuh/Waft = 14,432 Process 1.00 X 2819 x 0.000 Wafts/sgft X 3.41 BtuhMatt = 0 Infiltration: �� x Air Sensible � X Area J x Ceiling � X ACH / 60] Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 72,219 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 2 819 x 200 Btuh/occ. / 200 Sgft/occ. = 2 819 Receptacle 1.00 x 2 819 x 0.000 Watts/sgft X 3.41 Btuh/Waft = 0 Process 1.00 X 2 819 x 0.000 Wafts/sgft X 3.41 Btuh[Watt = 0 Infiltration: -Schedule 1.00 x 4 840 x 2 81 x Heigh x 60] 0.00433 = 7 187 "' Air Latent Area Ceiling Height ACH OW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 10,006 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 29 of 33 0 is RESIDENTIAL ROOM COOLING LOAD SUMMARY Decker Residence 6/2/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Living Area 78°F 115°F 370E Conduction Area U -Value DETD' Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an Interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btulhr FrnchDr 18 (East) 1 + + 1 + 1 + 1 + 1 + + 1 + 1 + 1 + East FxdGlsWdw 20 (East) FxdGlsWdw 21 Abv. (East) FmchDr (22) (South) FxdGlsWdw 23 (South) FxdGlsWdw 24 South FxdGlsWdw 25 South FXdGISWdW 26 Abv. (South) FXdGISWdW 27 South ( 0.0 X X1 x x x x x1 x x X 1 + + 1 + 1 + 1 + 1 + + 1 + 1 + 1 + 48.0 X X x x X x x x X x 73 )X ) x ) x x x ) x 0.668 = = = = = = = = = 2,340 ( 0.0 3.8 73 0.390 108 ( 0.0 10.0 73 0.334 244 ( 0.0 3.0 73) 0.390 85 ( 0.0 24.0 32) 0.668 513 ( 0.0 15.0 32)X 0.390 187 ( 0.0 15.0 32)X 0.390 187 ( 0.0 15.0 32)X 0.390 187 ( 0.0 3.8 32)x 0.390- 47 ( 0.0 10.0 32 0.390 125 Sched. Page Total a o2a Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 2,819 x 0.500 Watts/sgft x 3.41 Btuh/Waft = 4.811 Occupants 1.00 x 2,819 x 250 Btuh/occ. / 200 sgft/occ. = 3,524 Receptacle 1.00 x 2,819 X 1.500 Watts/sgft x 3.413 BtuhlWaft = 14,432 Process 1.00 x 2,819 x 0.000 Wafts/sgft x 3.41 Btuh/Watt = 0 Infiltration: �en L( x Airs x Area x Ceiling � x CH 50 / 60] 0 = t3 Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 72,2191 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 2 819 x 200 Btuh/occ. / 200 sgft/occ. = 2 819 Receptacle 1.00 x 2 819 x 0.000 Watts/sqft x 3.41 Btuh/Waft = o Process 1.00 x 2 819 x 0.000 Wafts/sqft X 3.41 Btuh/Waft = 0 Infiltration: �ehedu�e x Air Latent x Area x Ceiling Height x ACH50 / 60] ZNW .00433 = 7187 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 10,006 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 30 of 33 0 is RESIDENTIAL ROOM COOLING LOAD SUMMARY Decker Residence 6/2/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Living Area 780F 115DF 370E Conduction Area U -Value DETD 1 Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF Sc Btu/hr FxdGlsWdw 28 (South) FxclGlsWdw 30 Abv. (West) (West) FxdGISWdW 31 Abv. (West) FxdGlsWdw (32 Abv.) (West) FxdGlsWdw 33 Abv. (West) CsmntWdw 34 (West) FxdGlsWdw 35 est CsmntWdw 36 (West) FXdGISWdW 37 est ( 0.0 X1 X x x X XX x x x X + 1 + 1 + 1 + 1 + 1 + 1 + 1 + Al + 10.0 x X x X X x x X x 32) X ) x X x x X )xF 0.390 = = = = = = = = = 125 ( 158.0 42.0 73 0.40 2.179 ( 0.0 4.0 73) 0.390 114 ( 0.0 4.0 73) 0.39( 114 ( 0.0 4.0 73) 0.39( 114 ( 0.0 0.390 114 ( 0.0 10.0 73) 0.334 244 ( 0.0 10.0 73)X 0.390 284 ( 0.0 10.0 73)x 0.334 ( 0.0 26.3 73 0.390 748 Sched. Page Total 4,278 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 2,819 x 0.500 Watts/sgft x 3.41 Btuh/Watt = 4,811 Occupants 1.00 X 2,819 X 250 Btuh/occ. / 200 sgft/Occ. = 3,524 Receptacle 1.00 x 2,81 x 1.500 Watts/sgft x 3.413 Btuh/Watt = 14,432 Process 1.00 x 2819 x 0.000 Watts/sgft x 3.412 Btuh/Watt = 00 Infiltration: �� x Air Sensible � x Area x Ceiling � x ACH / 60] 4,T = L�3,LUSL1 Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 72,2191 Sched. Latent Gain_ Frac. Area Heat Gain Btu/hr Occupants 1.00 X 2 819 x 200 Btuh/occ. / 200 sgft/occ. = 2 819 Receptacle 1.00 x 2 819 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Process 1 1.00 X 2 819 x 0.000 Watts/sgft x 3.41 Btuh/Watt = Infiltration: 1.00 x 4 840 x 2 81 X 14.60 X 0.50 / 60] 1 0.00433 = 7 187 -Schedule Air Latent Area Ceiling Height ACH vW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 10,006 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 31 of 33 RESIDENTIAL ROOM COOLING LOAD SUMMARY Decker Residence 6/2/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value X DETD1 Living Area 780F 115°F 37°F Btu/hr 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxdGlsWdw 38 (West) ( 0.0 X 1 + 28.0 X 73)X 0.390 = 796 (West) ( 0.0 x 1 + 26.3 x 73 ) X 0.390 = 748 FXdGISWdW 40 Abv. (West) ( 0.0 x 1 + 6.0 x 73) x 0.390 = 171 ( x + x )X = ( x + x )x ( x + x )x - ( x + x )x = ( x + x )x = (-x + X )X Sched. Page Total 1 715 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 X 2,819 X 0.500 Watts/sgft X 3.41 BtuhMaft = 4,811 Occupants 1.00 X 2,819 X 250 Btuh/OCC. / 200' sgft/occ. = 3,524 Receptacle 1.00 x 2,81 X 1.500 Watts/sqft X 3.413 Btuh/Waft = 14,432 Process 1.00 x 2,819 x 0.000 Watts/sqft x 3.41 Btuh/Waft = 0 Infiltration: ( x Air Sensible x IArea � X Ceiling x ACH / 60] 0 =zo Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 72,219 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00x 2 819 x 200 Btuh/occ. / 200 sgft/occ. = 2 819 Receptacle 1.00 x 2 819 x 0.000 Wafts/sqft x 3.41 Btuh/Waft = 0 Process f 1.00 X 2 819 X 0.000 Watts/sgft x 3.41 Btuh/Waft = Infiltration: I 1.00 x 4840 Air Latent Area Ceiling Heighx 2 81 x Height x ACH 60] 0.00433 = 7 187 ehedule OW • Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 10,006 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 32 of 33 • Ll RESIDENTIAL ROOM COOLING LOAD SUMMARY Decker Residence 6/2/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Guest Suites 78°F 115°F 370E Conduction Area U -Value DETDBtu/hr R-38 Roof R.38.2x14.16 -1 Wall .21.2x6.16 Fleetwood Glazing Lo/E -2 Wall .21.2x6.16 Fleetwood Glazing Lo/E Default Single NonMtl Tinted X X X X X X 56.0 = = = = = = 1,165 35.6 1,175 37.0 741 35.6 277 37.0 204 37.0 3.516 X X X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total 7 078 Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr CsmntWdw 41 (North) rsmntWdw (42) (North) CsmntWdw 43 (North) DblCsmntWdw 44 (North) FxdGlsWdw (45) (East) FrnchDr 46 (East) FxdGlsWdw 47 Abv. (East) FrnchDr 48 (South) 19 ( 0.0 119+ 3.8 ( 0.0x1 x x x X X x1 x x X + + + + + + + + 3.8X X X x x X x x X X 15)X )X x x X X X )X )X 0.334= = = = = = = = = 19 ( 0.0 1 3.8 15 0.334 19 ( 0.0 119+ 3.8 15)X 0.334 19 ( 0.0 A 25.0 15) 0.334 125 ( 0.0 1 10.0 73) 0.390 284 ( 0.0 1511+ 48.0 73) 0.668 2,340 ( 0.0 3.8 73) 0.390 108 ( 0.0 1 48.0 32) 0.668 1,026 ( ( Sched. Page Total 3 941 Internal Gain _ Frac. Area Heat Gain Btu/hr Li hts 1.00 x 743 x 0.500 Watts/sgft x 3.411 Btuh/Waft = 1,268 Occupants 1.00 X 743 X 250 Btuh/OCC. / 200 sgft/OCc. = 929 Receptacle 1.00 x 743 x 1.500 Wafts/sqft x 3.413 Btuh/Waft = 3,804 Process 1.00 x 743 X 0.000 Watts/sgft X 3.412 Btuh/Waft = 0 Infiltration: � xairs x x x / 60] CeilingArea 11.�o eight ACH 0 = Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19,790 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 743 x 200 Btuh/occ. / 200 sgft/occ. = 43 Receptacle 1.00 x 743 x 0.000 Watts/sgft X 3.41 Btuh[Waft = o Process 1.00 x 743 x 0.000 Wafts/sgft x 3.41 Btuh/Waft = 0 Infiltration: Cschedu�e x Air Latent X area 74 X Ceiling Height x 60] actOt50 / lOV00433 = 1453 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,196 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 33 of 33 Jan 11 05 11:34a RF STRUCTURAL&SANTAMARIA 760 836 0856 JANUARY 11, 2005 PETER JACOBS HC)Mt—S 54-995 SHOAL CREEK LA QUINTA, CA. 92253 Attn.: MR. PETER JACOBS Re.: THE DECKER RESIDENCE THE HIDEAWAY LOT 4 249 53-395 VIA STRADA LA QUINTA, CA. 92253 FOLLOW-UP TO WALK THROUGH JOB NO.: 4171 DEAR PETER P.1 STRUCTURAL CONSULTANTS, INC, 75-i 53 MERLE DRIVE, S TE_ B, PALM DESERT. CA 972 i .i PHONE (760) 836-1000 FAX (760) 836-0856 E- ;MAIL RAYW0�\,'D c S T RvC T U_ AL. CO' THIS LETTER ADVISES THAT 1WE HAVE OBSERVED THE STRUCTURAi. REQUIREMENTS THAT ARE, VISIBLE DURING CONSTpUC_T�X;p, THE TIME OF OUR SITE VISIT. F ' ;, ` s Y C., Y.:-:!'• +"s , ". e ., .; ear. �C�:ti4.•'..PJ�•.7tikra..d;' WE BELIEVE THAT THE AS -BUILT CONSTRU 1N GENERAL CCTION AT THE TIME OF OUR VISIT IS ONFORMANCE WITH OUR STRUCTURAL PLANS AND RELEVANT CORRESPONDENCE ISSUED BY OUR OFFICE. WE OBSERVED THE BUILDING IN ITS FRAMED ITION PRIOR INSTALLATION OF DRYWALL AND STUC . WE OBSERVED THE VISOUA ACCESSIBLE STRUCTURAL REQUIREMENTS. (EXCLUSIONS ARE ITEMS SUCH AS: FOOTING SIZE AND REINFORCEMENT, TOP PLATE SPLICES, ROOF SHEATHING, AND ANY STRAPS ABOVE THE ROOF SHEATHING.). RESPECTFULLY SUBMITTED QROE ESS101AV, M. FgPry ��2� c� m No. 57958 Exp. 06 30 -Ota tp C 1 V11- ZEYAD FAQ1H, PE qTF OF CAL�F�� "tel - 1ti TANDY'S INSPECTION SERVICES, INC. PO BOX 13766 - PALM DESERT, CA 92255-376,6 OFFICE / FAX - 951.769.9717 y PAGER 760.776.3339 SPECIAL INSPECTORS REPORT OF SHOP FABRICATION TYPE OF INSPECTION PERFORMED DATE SHOP WELDING WEDNESDAY, JULY 14, 2004 PHYSICAL ADDRESS PERMIT NUMBER 53-395 VIA STRAGO - L,QUINTA , JOB NAME TYPE OF STRUCTURE DECKER RESIDENCE 9 THE HIDEAWAY SFD ARCHITECT ENGINEER SOUTH COAST .'RF STRUCTURAL GENERAL CONTRACTOR SUB CONTRACTOR PETER JACOBS WHITES STEEL DESCRIPTION OF WORK INSPECTED 7/9 & 7/14 OBSERVED SHOP WELDING OF COLUMNS AND BEAMS. SEE STRUCTURAL STEEL SHOP WELDING FABRICATION REPORT ON BACK SIDE OF THIS REPORT. SHOP WELDING COMPLETE CORRECTIONS AND/OR NOTES WELDING INFORMATION PROCESS & ELECTRODE SMAW - E7018 FCAW - E71T-8 _ WELDERS NAME CERTIFYING AGENCY AND CERTIFICATION NUMBER GUADALUPE AMAVICA EARTH SYSTEMS #ES1183 -34 & -12 ISHMAEL AYALA EARTH SYSTEMS #ES4001 I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING LAWS. INSPECTORS SIGNAT ICC 1111326- OS INSPECTORS CERTIFICATION AGENCY AND NUMBER STRUCTURAL STEEL SHOP WELDING FABRICATION REPORT Fabricated at: WHITES STEEL Start Date: Finish Date: 1 O Physical Address: 53-395 VIA STRAGO - LA QUINTA Job Name: DECKER RESIDENCE@THE HIDEAWAY Contractor: PETER JACOBS Engineer. RF STRUCTURAL Architect SOUTH COAST - PIECE NUMBER QTY SIZE SHAPE SINGLE ASTM # PASS COLUMNS CJP WELDING NDT DATE REMARKS 1 A 1 6" X STG ( A 53 GR. B AGL 18 1 G" X STG A 53 GR. B it. Ct. 1 C 1 G" X STG (b A 53 GR. B ( 1 D 1 6" X STG 4) A 53 GR. B iD�CG 1 H 1 6" X STG 4) A 53 GR. B wc(G BEAMS 1 F 1 1 Ox45 A 36 _ GC 1/2" CAMBER 1 G 1 10x45 'I. A-36 1/2" CAMBER All matenar conforms to the approves ranncamrs bnop urawmgs ACC in SINGLE PASS or CJP WELDING columns represents acceptable welding and no corrective work required NDT DATES is date Non -Destructive Testing ( Ultrasonic or Magnetic Particle) was performed