Loading...
04-6779 (SFD)3ox 1504 5 CALLE TAMPICO JINTA, CALIFORNIA 92253 �r Application description Property Zoning . . . . . Application valuation . . BUILDING PERMIT BUILDING & SAFETY DEPARTMENT (760).777-7012 FAX (760) 777=7011 INSPECTION REQUESTS (760) 777-7153 04-00006779 Date 3/25/05 53356 VIA STRADA 772-520-053- - - DWELLING - SINGLE FAMILY DETACHED LOW DENSITY RESIDENTIAL 565293 Owner Contractor ------------------------ CHRIS HARRIS ----------------- HARRIS HOMES INC 2127 PALOS VERDES DR. N 2127 PALOS VERDES DRIVE NORTH LONG BEACH CA 90807 LOMITA CA 90717 (310) 325-6355 WCC: STATE FUND WC: 1773515 01/01/06 CSLB: 231712 04/30/05 CCC: B ------ Structure Information 6391 SQ. FT. SFD ----- Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/LONG <=10 Flood Zone . . . . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC # BEDROOMS 5.00 FIRE SPRINKLERS NO GARAGE,SQ FTG 1627.00 PATIO SQ -FTG 1279.00 •NUMBER OF UNITS 1.00 ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 6391.00 Permit BUILDING PERMIT Additional desc Permit Fee . . . . 2237.50 Plan Check Fee 1454.38 Issue Date . . . . Valuation . . . . 565293 Expiration Date 9/25/05 Qty Unit Charge Per Extension BASE FEE 2039.50 66.00 3.0000 ---------------------------------------------------------------------------- THOU BLDG 500,001-1,000,000 198.00 Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee . . . . 286.23 Plan Check Fee 71.56 Issue Date . . . . Valuation . . . . 0 Expiration Date 9/25/05' .Qty Unit Charge Per Extension BASE FEE % 15.00 6391.00• .0350 ELEC NEW RES - 1 OR 2 FAM;LY 223.69 P.O. BOX 1504 • /i • w VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-701N LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Tr Application Number: Applicant: �� ' Applicant's Mailing Address: Date: Architect or Engineer: Architect or Engineer's Address: Lic. No.: t3UILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License i full force and effect. 17/2,License Class License No. Date 3 aSo Contractor IAV Namers /,iC OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. . BA P.C. for this reason Date WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My w rkers' compensation insurance carrier and policy number are: Carrier 57*71F tyAIQ Policy Number / 107 Z I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date <.aplicant WARNING: FAILURE TO SECURE WORKERS' COMPE SATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter up n the above-mentioned property for inspection. purposes. Date 3 a 5 b5- Signature (Applicant or Agent): Page 2 Application Number . . . . 04-00006779 Date 3/25/05 Qty Unit Charge Per Extension 1627.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 32.54 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 -------------------------- Permit . . . . . . --------------------------------------- GRADING PERMIT ----------- Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation. 0 Expiration Date 9/25/05 Qty Unit Charge Per Extension ------------------------------------------------------ BASE FEE 15.00 ------------------ Permit MECHANICAL Additional desc Permit Fee . . . . 119.50 Plan Check Fee 29.88 Issue Date . . . . Valuation . . . . 0 Expiration Date 9/25/05 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 9.0.000 EA MECH FURNACE <=100K 36.00 4.00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 4.00 6.5000 EA MECH VENT FAN 26.00 1.00 6.5000 -----------------------------------.-------------.---- EA MECH EXHAUST HOOD 6.50 ------------------------ Permit PLUMBING' Additional desc Permit Fee . . . . 237.75 Plan Check Fee 59.44 Issue Date Valuation 0 Expiration Date 9/25/05 Qty Unit Charge Per Extension BASE FEE 15.00 26.0.0 6.0000 EA PLB FIXTURE 156.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 13.00 .7500. EA PLB GAS PIPE >=5. 9.75 1.00 15.0000 ---------------------------------------------------------------------------- EA PLB GAS METER 15.00 Special Notes and Comments 6391 SQ. FT. SFD THIS PERMIT DOES NOT INCLUDE POOL & SPA BLOCK WALLS OR Page 3 Application Number . . . . . 04-00006779 Date 3/25/05 ---------------------------------------------------------------------------- Special Notes and Comments DRIVEWAY APPROACH. 11/9/04 8:09:20 AM JJOHNSON ----------------- --------------------------------------------------------- .Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 913.23 DIF COMMUNITY CENTERS -RES, 97.00 ,DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 145.44 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE 00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 56.52 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary ----------------- Charged Paid Credited Due Permit Fee Total -7--7 ----- 2895.98 -------------- ------ ---------- .00 .00 2895.98 Plan Check Total 1615.26 1000.00 .00 615.26- 15.26Other OtherFee Total 3520.19 -.00 .00 3520.19 Grand Total 8031.43 1000.00 .00 7031.43 wilding ? y ddress P.O. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO �' L .-P{i LA QUINTA, CALIFORNIA 92253 uwneerr / Gil il,67 Mailing ) Address /!i 1/L-7 N City Zip I LaM (Tih . 4,4k a1 D 7 �►�) 3x5.103 Address City lZip JTel. State Lic. (City & Classif. Lic. # signer'..'( �V J C% Wf /,W&t� -,:WM E0 I Ad ress - I Tel 7� • 854- v�C �► i� 4 4.0 •3 28 �,ft r�LI IState y]M_"•�((p/i��A� 7v�7vw.�/ylLic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this Permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CONSTV•, 4fk OCCP. C.. GR A.P. Number r. 7►' E7 A/ �✓ Q� Legal Description Projectescription --o-:21KWE 4 �v(0L�v W*TO ZONE: BY: It Minimum Setback Distances: dl11, Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by:— Validated by: Validation: YELLOW = APPLICANT Date Permit PINK = FINANCE Sq. Ft. .y,� ` Size t 1 No. 1 No. Dw. ' Stories l Units NewX Add ❑ Alter ❑ Repair ❑ Demolition ❑ 3 10 - %0- S7-/ YV Glez� 310 - 31� &39V WK. XA10 Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. QQ Plan Chk. Bal. Const. Mech. Electrical Plumbing f . S.M.I. Grading Driveway Eno. f U I Infrastructure ) 1_ 104 ;' '-/f j Q11 r ur TOTAL REMARKS A i l A •i As U 4e + ZONE: BY: It Minimum Setback Distances: dl11, Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by:— Validated by: Validation: YELLOW = APPLICANT Date Permit PINK = FINANCE Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 – Fax (760) 398-1224 Project Name: Owner's Name: Chris Harris This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMIIND. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Address: 53-356 Via Strada, La Quinta, CA 92253 Project Description: Single Family Home APN: 772 520 053 t#: 0 Type of Development: esidential . xx Commercial Total Square Feet of Building Area: 6391 Date: 3/17/05 Phone No. 310 466 5440 Lot #'s: a l0 Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: 3b 171 DS- Signature: ***************************************************b*-****************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code 65995 6391 $2.68 $17,127.88 Building Permit Application Completed: Yes/No Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement By: Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: Marcela Valdez, Facilities Secretary Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1)aiv itten notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest Imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. N.-IV:c/mydocs,'devfces/certificate of compliance form tables f0 USEs.doc 1/16/03 T W EDDLE SURVEYING MAPPING, INC. Boundary • Construction • Topographic • Aerial Surveys • ALTA Surveys • GPS • Consulting May 18, 2005 53-36 � �i,, 9wt*� Mr. Timothy R. Jonasson Public Works Director / City Engineer City of La Quinta 78-495 Calle Tampico La Quinta, CA 92253-1504 Re: Pad/Form Grade Verification City of La Quinta Lot 269 Tract No. 29894-2 Amended THE HIDEAWAY APN 772-520-053 Dear Mr. Jonasson: We have performed a field survey to determine the vertical location of the building pad and form for the above referenced project. The elevation's observed are as follows: PAD (DESIGN) PAD (AS -BUILT) 1012.80 1012.8 FORM (DESIGN) FORM (AS -BUILT) 1013.55 1013.57 These field observations are in substantial conformance with the precise grading plan prepared by McGLOIN ENGINEERING, dated 10/09/2004 and the building horizontal location substantially conforms to the required setbacks and site layout as shown on the approved site plan. Sincerely, WEDDLE SURVEYING MAPPING, INC. \_NND 9U, U r O NO. 5570 m David L. Weddle, President �c EXP. 09/30/05 L.S. 5570, Exp 9/30/05 OF CALF P.O. Boz 10418 • Palm Desert, CA 92255-0418 73-960 Hwy. 111, Ste. 6 • Palm Desert, CA 92260 • 760.346.3748 E -Mail: WedSury@aol.com • Fax 760.346.3 749 r Certificate' of Occupancy 5 V 4 �lG`'� Lac_•-cnro OF IBuilding & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 53356 VIA STRADA Use classification: SFD Building Permit No.: 04-7669 Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL Owner of Building: CHRIS HARRIS Address: 2127 PALOS VERDES DR. N City, ST, ZIP: LONG BEACH CA 90807 By: STEPHEN WHITTLET �- Date: 3-31-06 Building Offici POST IN A CONSPICUOUS PLACE Al 11 1 ,- A, I TITLE 24 REPORT Title 24 Report for: CHRIS HARRIS LA Q U I N TA, CA Project Designer: CHRIS HARRIS LA QUINTA, CA CITY OF LQ repared By: BUILDING & S APP(ANA GIL FOR CONS Group oA 6erf, e Way, Suite 5 CA 92260 340-3528 Job Number: ADY91-1004 pS Date: 1/27/2005 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: ADY91-1004 User Number: 5553 1 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R CHRIS HARRIS 1/27/2005 Project Title Date LA QUINTA Project Address Building Permit # GLS Group (760) 340-3528 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check I Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 6,433 ft2 Average Ceiling Height: 11.9 ft Total Conditioned Slab Area: 6,433 ft2 Building Type: Frame Type (check one or more) R-38 Roof (R.38.2x4.24) Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (Northwest) 315 deq Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Component Type Frame Type Const. Assembly U -Value R-38 Roof (R.38.2x4.24) Wood 0.024 Slab On Grade n/a 0.756 R-19 Wall w/1" EPS Wood 0.045 Solid Wood Door None 0.387 Slab On Grade n/a 0.756 FENESTRATION Location/Comments (attic, garage, typical, etc.) Exterior Roof Covered Slab w/R-0.0 Perimeter Insulation Exterior Wall Exterior Door Exposed Slab w/R-0.0 Perimeter Insulation Shadina Devices Type Orientation Area SF U -Factor Fenestration SHGC Exterior Shading Overhang Side Fins Yes / No Yes / No Left (Northeast) 42.0 0.42 0.32 Bug Screen ❑ X❑ ❑ Front (Northwest) 42.0 0.42 0.32 Bug Screen ❑ X❑ ❑ X❑ Front (Northwest) 3.2 0.40 0.39 Bug Screen ❑ ❑ Right (Southwest) 66.0 0.42 0.32 Bug Screen ❑ X❑ ❑ X❑ Right (Southwest) 50.0 0.44 0.29 Bug Screen ❑ ❑ X❑ Right (Southwest) 16.0 0.40 0.39 Bug Screen ❑ X❑ ❑ X❑ Right (Southwest) 30.0 0.50 0.30 Bug Screen ❑ x❑ ❑ x❑ Rear (South) 41.5 0.40 0.39 Bug Screen X❑ ❑ ❑ x❑ Rear (Southeast) 236.0 0.45 0.35 Bug Screen x❑ ❑ ❑ Q Left (East) 41.5 0.40 0.39 Bug Screen X❑ ❑ ❑ 0 Rear (Southeast) 84.8 0.40 0.39 Bug Screen x❑ ❑ ❑ X❑ Right (Southwest) 80.0 0.45 0.35 Bug Screen X❑ ❑ ❑X❑ Run Initiation Time: 01/27/05 16:50:54 Run Code: 1106873454 Ener Pro 3.1 By Ener Soft User Number: 5553 Job Number: ADY91-1004 Pa e:3 of 17 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R CHRIS HARRIS 1/27/2005 Project Title Date LA QUINTA Project Address Building Permit # GLS Group (760) 340-3528 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 6,433 ft2 Average Ceiling Height: 11.9 ft Total Conditioned Slab Area: 6,433 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (Northwest) 315 deq Number of Dwelling Units: 1.00 Number of Stories: 1 BUILDING SHELL INSULATION Floor Construction Type: ® Slab Floor ❑ Raised Floor Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) FENESTRATION Shadina Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front (Northwest) 28.0 0.44 0.29 Bug Screen x❑ ❑ ❑ x❑ Front (Northwest) 96.0 0.45 0.35 Bug Screen x❑ ❑ ❑ X❑ Front (Northwest) 4.4 0.44 0.29 Bug Screen ❑X❑ ❑x❑ Left (Northeast) 11.2 0.40 0.39 Bug Screen ❑ ❑ Q Left (Northeast) 16.0 0.42 0.32 Bug Screen 191 ❑ ❑ Rear (Southeast) 16.0 0.42 0.32 Bug Screen[R] ❑ ❑ o Left (Northeast) 10.2 0.40 0.39 Bug Screen X❑ ❑ ❑ x❑ Rear (Southeast) 4.5 0.40 0.39 Bug Screen ❑ o ❑ o Right (Southwest) 24.1 0.40 0.39 Bug ScreenX❑ ❑ ❑X❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 01/27/05 16:50:54 Run Code: 1106873454 Ener Pro 3.1 By Ener Soft User Number: 5553 Job Number: ADY91-1004 Pa e:4 of 17 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R CHRIS HARRIS 1/27/2005 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback— HVAC Syst- Zone I f entmi Furnace 80% AFUE bunts in Attic 42 Setback HVAC Syst. Zone II Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC Syst. Zone III Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 Setback_ HVAC Sy. -;t lone I Split Air Conditioner 12„2 ,';FFR Ducts in Attic 42 Setback HVAC Syst Zone II Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC Syst- Zone III WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.O.Smith FSG -75-230 Small Gas Standard 2— 75,000 74 0.48 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS GOMPLIANCE 5TATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design respoppibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification an ' verificatio y an approved HERS rater. eSl r OrIfir (per Business 8 Professions Code) ame:� ' Title/Firm: cL4S HARRIS Address: LA QUINTA, CA Telepho e: Lic. #: (sign ure) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Documentation Author Name: ADRIANA GIL Title/Firm: GLS Group Address: 74-854 Velie Way, Suite 5 Palm Desert, CA 92260 Telephon : (760) 340-3528 G ,11 VIA (signature) (date) natu IEnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page:5 of 17 1 Certificate of Compliance: Residential (Addendum) CF -1 R CHRIS HARRIS 1/27/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "A.O.Smith FSG -75-230" Energy Factor = 0.480. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC Syst. Zone I " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2499 sqft Covered Slab Floor, 3.50" thick at Zn I Mstr. Bdrms, Bdrms 4&5 The HVAC System "HVAC Syst. Zone II " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1679 sqft Exposed Slab Floor, 3.50" thick at Zn II Hall, Lvng,GreatRm The HVAC System "HVAC Syst. Zone III " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -21R) - Verify Thermal Mass: 1700 sqft Exposed Slab Floor, 3.50" thick at Zn III Bdrms,Dnng,Nook HIGH MASS Design(see C -2R) - Verify Thermal Mass: 555 sqft Covered Slab Floor, 3.50" thick at Zn III Bdrms,Dnng,Nook HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS ..,... .........— —1.. wo.—. a..0 u.oul— v — Neu v. umc = mcaaufca vn a wnn a.r-ort. I Plan I Field EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page:6 of 17 1 Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ❑X I150(a): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturer's labeled R -Value. ❑*§150c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does X not apply to exterior mass walls). ❑ '§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(l): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. a§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑%� § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures X§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. X§150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA. ❑X §150(1): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page:7 of 17 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) Al '§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. X❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. X] §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page:8 of 17 Computer Method Summary (Part 1 of 3) C -2R CHRI_S_HARRI_S Act. 1 /_2.7J2QQ5 Project Title U -Fac. Azm. Date -LA_QU INTA_ -2,499 _0.02.4_ --A-5 1.8_ Project Address GLS 11_4_ _0..0.4.5. 5. -45--90- Building Permit # -G-coup 4.8. _0..38.7_ (760)--340-3528 Documentation Author 26 0.045 Telephone i Plan Check/Date Com ute._P_erf_or_mance pr _0.387_ 15 -9-0- 90Wall_ Field Check/Date Compliance Method (Package or Computer) _0...0.45_ Climate Zone -90- 90_Wall_ Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.30 3.13 0.17 Space Cooling 33.77 29.71 4.06 Domestic Hot Water 4.43 6.56 -2.13 Totals 41.49 39.40 2.09 than Standard: Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units; Number of Stories: BUILDING ZONE INFORMATION Zone Name 5.0% 6,433 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Single Fam Detached (Northwest) 315 deg Total Fenestration Area: 14.7% 1.00 Total Conditioned Volume: 76,664 ft' 1 Total Conditioned Slab Area: 6,433 ft 2 # of Floor Area Volume Units Zone Type _HVA_ C_Syst-Zone_I _ 2,4.99 _2.4,992 _0.3.9_ Conditioned_ _FLVP_AC_Syst-Zone_1I_ _ 1.,6.7.9 _24,61.6 _0.26_ -Conditioned- -H-VA- onditioned_ JiVA_C_Syst.-Zone-III _ 2,25.5. _22,.0.5.6 _0.25_ Conditioned_ OPAQUE SURFACES Act. Type Area U -Fac. Azm. Tilt .Roof- -2,499 _0.02.4_ --A-5 1.8_ Wall- 11_4_ _0..0.4.5. 5. -45--90- 90_.Door .Door- 4.8. _0..38.7_ -45--90- 45__90_Wall- Wall- 26 0.045 1-35-90 -Door2.4_ _0.387_ 1.35 -9-0- 90Wall_ -Wall- 5.5_ _0...0.45_ 4.5. -90- 90_Wall_ -Wall 30 0.0_4.5 135 _90 Wall_ 1.8_ 0.0_4.5 45 90 Wall_ 30_ _0.0.45_ _31.5 -90- 90_Wall- -Wall 6.0_ _0..04.5_ 4.5. -90- 90_Wall_ -Wall 55_ -0,0-4-5- 31.5 90 Wall_ 30_ 0,045 45 90 Wall- 28. _0._04.5_ _31.5. 9.0_ Wall- 3.0_0 045 _225_ --90- -Wall- 55_ _0...045_ 315 9.0_ Wall_ 1.0. _0...0.4.5_ -225_ __9.0_ Wall- 8.7_ _0..04.5_ _31.5. 9A_ Wall_ 472. _0...0.4.5_ -225. 9.0_ Wall- 20 0.0_4.5 31.5 -9-0- 0Wall- -Wall- 7_1. -0,0-45- _225 90 Wal. 20 0045 1.35 90_ Wall_ 1.7.2. _0...0.4.5_ _225. 9.0_ Wall_ 33_ _0...0-4.5_ -31.5. 9.0_ Wall_ 1.0.6_ _0..0_4.5_ _225. 9.0_ Wall_ 26_ _0...0.4.5_ 18.0. 9.0_ Wall- 22. 0.0_4.5 135 _ 90_ WaH- 26 0.045 90 _-90_ Wall- 33 0045 4.5 90 Wall- 1.32. _0.0_4.5 90 90_ Solar Gains Y / N Form 3 Reference _R_38 Roof_(R,38.2x_4..2.4.) _R_1.9_W a I I_w/_1_E P_S _Solid_W_ood_Doo.r . R -1.9_W a I I _w/_1 -"EPS Solid -Wood -Door R -1.9_W a l l __w/-1 _ E P_S . R -1.9_W a l l _w /_1_ E P_S .R -1.9_W_ _all_w/-1_EP_S _R-1.9_Wall_w/_L" EP_S R_19_Wall_w/-1_EP_S R _1.9_W a l l _w /-1 _ E P_S _R-1.9_Wall_w/_L" EP_S RR=19 Wall w/1" EPS .R-1.9_Wall_w/-L" EPS R -1.9_W a l l __w/-1 _ EPS . R A -9_W a I I _w/_1 _ E P_S _R_1.9_W al I-w/_1_EP_S R49_Wal1_w/-1 °.EP_S _R -19_W a I I__w/_1_EPS _13-1.9_W all_M-1_E S. _R -1.9_W all_w/_1_E P_S _R -1.9_W a l l__w/_1-E P_S RA.9_WaII_w/_11EP_S .R-1.9_Wall-w/-L" EPS _R_1.9_W a I I_w/_1_E P_S- R_-9_Wall w/-1_EP_S _R -1.9_W all_w/_1_EP-S R_1.9_W all_w/-1_E P_S R_19_W_ _all_w/- " EP -S Thermostat Vent Type Hgt. Area -Setback_ 2 _n/a _S.etb.ack_ 2 _n/.a _S.etback- 2 _n/a Location / Comments .Zn_I_Mstr._B.drm,_2_Bdrms .Zn_I_Mstr_Bdrm,_2_Bdrms .Zn-I_Mstr. Bd rm,_2_Bdrms Zn_I_M str. Bd rm.,_2_Bd rm s .Zn_I_Mstr B.drm,_2_Bdrms .Zn_I_M str. Bd rm f2_Bd rms .Zn_I_M str.. B d rm,_2_Bd rm s .Zn_I_M str. B d rm,_2_B.drm s .Zn_I_Mstr..Bd rmr2Bdrms .Zn_I_Mstr.Bd rmr2Bdrms .Zn-1_Mstr. Bd rm,2_Bdrms .Zn_I_M StLBd rm,_2Bdrms .Zn_I_Mstr_ Bd rm,_2_Bdrms Zn_I_Mstr_ Bd rm,_2Bdrms .Zn_I_Mstr._Bd rm,_2_Bdrms Zn_I_Mstr.. Bd rm,2_Bdrms .Zn_I-Mstr_ Bdrm,_2_Bdrms .Zn_I_Mstr-Bdrm,_2_Bdrms .Zn_I_Mstr. Bd rm,_2Bdrms .Zn_I_M str_ Bd rm,2Bdrm s Z n_I_M st r.. B.d rm ,_2_B.d rm s 2n_1_MStr_Bd rm,2Bdrms .Zn_I_Mstr.. Bdrm,_2_Bdrms .Z n_I_M str.. Bd rm,_2_Bd rm s .Zn_I_Mstr_ Bd rm,_2_Bdrms Z n_I_M str.. Bd rm,_2_B.drm s Zn_I_Mstr.-Bdrm,_2_8.d rms .Zn_l_Mstr.Bdrm,_2_Bd rms Zn_I_M str.. Bd rm,_2Bd rm s Run Initiation Time: 01127105 16:50:54 Run Code: 1106873454 _I EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page:9 of 17 Computer Method Summary Act. Azm. Tilt (Part 1 of 3) C -2R CHRISJ-�ARRI_S 1.35 0.04.5 1127120-0-5 Project Title :X Date -LA Q_U I_N_- A_ _0._024_ _31.5_ 1.8_ Project Address 1 u Wall- Building Permit # GLS Gr_ou.p -225. (760) 340-3528 lX Documentation Author Wall_ Telephone Plan Check/Date Computer_Rer_for_mance 90 15 Field Check/Date Compliance Method (Package or Computer) 1.88 Climate Zone -31590 Source Energy Use Standard Proposed Compliance Wall_ (kBtu/sf-yr) Design Design Margin 9.0_[X Space Heating 3.30 3.13 0.17 160 Space Cooling 33.77 29.71 4.06 AXI Domestic Hot Water 4.43 6.56 -2.13 0.02.4_ Totals 41.49 39.40 2.09 ❑ than Standard: 5.0% Total Conditioned Floor Area: 6,433 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Type: Single Fam Detached Building Front Orientation: (Northwest) 315 deg Total Fenestration Area: 14.7% Number of Dwelling Units: 1.00 Total Conditioned Volume: 76,664 ft' Number of Stories: 1 Total Conditioned Slab Area: 6,433 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area OPAQUE SURFACES Type Area U -Fac. Act. Azm. Tilt Solar Gains Y / N Wall_ 1.35 0.04.5 135. 90 :X .Roof 1,679 _0._024_ _31.5_ 1.8_ �_ 1 u Wall- 95_ -0...045_ -225. 9.0_ lX ❑ Wall_ 215 0945 t35 90 AXI ❑ Wall_ 1.88 0.045 -31590 LX ❑ Wall_ 7.2. _0._045_ 4.5. 9.0_[X ID 160 0.0_4.5 _3_1.5 __90 AXI ❑ _Roof _2,255 0.02.4_ 315 18_ LX ❑ Wall_ 11.6_ _0...0.4.5_ -225. 9.0_ LX ❑ Wall- 254_ -0..0.4.5_ -31.5_ _9.0_r LX 1:1_Doo 26 0...387 -315 90. LX ❑ Wall_ 1.0 -0-0-4.5- 45 90 [XI ❑ Wall- 62. _0..045_ _31.5. 9.0_ ❑ Wall - 0_ 0.045 -22590 LX ❑ Wall_ 122_ 0..045_ 315 _9.0_ LX ❑ Wall_ x_52. _0..0.4.5_ -45--90- LX ❑ Wall- 90_ -0._045_ 1.3.5. 9.0_ LX ❑ Wall_ 15.8_ _0_0.4.5_ 4.5_ _9.0. LX ❑ Wall- ----104 0.045 -1-3.5--90 [XI ❑ Wall -4_41 00_4.5 45 90 [XI ❑ .Door 51 0.387_ 4.5 90 LX ❑ Wall- 82. _0..0_4.5_ 1.35. 9.0_ LX J Wall_ 8.6_ -0...0_4.5_ -45--90- LX ❑ _Door 24 _0..3.8.7_ 45_ 9.0_ LX ❑ Wall- 30_ _0...0_4.5_ _9.0. 9.0_ LX ❑ Wall_ 84 0.045 1.35 90 LXI ❑ Wall- 30 0.0_4.5 1.8.0. 90 [XI ❑ Wall- 62_ 004.5 _225 90 A ❑ -Door2.4_ 0.387 _225. 90 LX ❑ Form 3 Reference _Rd_9_Wall_wL1"EP_S _R_3.8_Roof_(R. $8.2x4.2.4.) .R_1.9_Wall_wtl"" EP-S- -13=19-Wall-w]-l" P_S _R_1.9_W_ all_wl_1"EP_S .R_1.9_WaILw/1"ERS- R=19-Wall-WILE S P_S.R_1.9_Wallw/_1°EP_S .R_1.9_WaII wL1_E.P_S R_38_Roof_(R.38.2x4.24) .R_19_W a I I_w/_1"E P_S _R_19_Wall_w/_1° EP_S -Solid-Wood-Door .R-7-1-9-Wall-w./-1-"EP-S- R-19 R_1.9_Wall w/_1_EP_S R=19 Wall w/1" EPS .R=1 -9 -Wall -w/-1" EP_S .R_1.9_Wall_w/_1"EP_S . R _1.9_W a l l _w/_1"E P_S .R_1.9_W al l-w/_1_EPS _R_1.9_W a I I _w/_1_E P_S .13_1.9_Wa ILw/_ " EP_S . R _1.9_W a l l _w /_1"E P_S Solid -Wood -Door .R_1.9_W a l I _w/_1_E P_S _R_1.9_W a II_w/_1_EP_S _S.olid_Wood_Doo.r .5L1.9 -Wall -w/ -1-"E S R_19_W_ __all_M-1_EP_S .R_1.9_W a I I_w/_1"E P_S _Rd9_Wall w/_1"EP_S -S-olid-Wood-Dow Location / Comments .Zn_I_M str. Bd rm.,_2_Bd rm s .Zn_I I_Hal I, Lvng,.G rtRm .Zn_ll_Hal I, Lvng,GrtRm .Zn_I I_Hall, Lvng,G rtRm .Zn_LI_Hal I, Lvng,GrtRm .Zn_ll_Hall, Lvng,.GrtRm .Zn_LI_Hal I, Lvng,GrtRm .Zn -I LI_Bdrms,Dnng,Nk .Zn_LLI_Bd rms, D.n n g, N k .Zn_LLI_Bd rms,Dn ng, Nk .Z n_LLI_Bd rm s, D.n n g , N k .Z n_l l l_Bd rm S, D.n ng,N k .Z n_ll l_Bd rm s, D n ng, N k .Zn_I LI_Bd rms, D.n n g, N k Z n_ll l_Bd rms, D.n n g, N k .Z n_I Il_Bd rms, D n n g, N k .Zn_lll-Bd rms, D.n ng, N k .Zn_I Il_Bdrms,D.n ng,N k .Z n_ll I_Bd rm s, D.n n g, N k .Zn_l l l_Bd rm s., D.n ng, N k Zn_II.I_B.drms.,Dnng,Nk .Zn_I I I_Bd rms, Dn n g, N k .Zn_I I I_Bdrms, Dnng,N k .Zn_ll I_Bd rms,D.nng, N k .Zn_ILI_Bd rms,D.nng, Nk .Z n_LLI_Bd rm s, D n n g, N k .Z n_ll I_Bd rm s, D.n n.g, N k .Z n_ll I_Bd rm s, D n ng, N k .Zn_LLI_Bd rm s,D.n n g,N k I EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Paae:10 of 17 1 Computer Method Summary (Part 2 of 3) C -2R CHRIS HARRIS 1/27/2005 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments 1_ Window -Left - (Northeast) 42.0_ _0.._420_ _0.32. 45_ _9.0. FLEET-_ _OQD ALUMINUM -Zn_I_Mstr.B_drm,2Bdrms_ 2 Window Front(Northwest) 42.0 0.420 0.32 315 90 FLEETWOOD ALUMINUM _ Zn I Mstr.Bdrm, 2 Bdrms 3 Window Front Northwest) 3.2 0.400 0.39 315 90 FLEETWOOD ALUMINUM Zn I Mstr.Bdrm, 2 Bdrms 4 Window Right Southwest) 9.0 0.420 0.32 225 90 FLEETWOOD ALUMINUM Zn I Mstr.Bdrm, 2 Bdrms 5 Window Right Southwest) 25_0 0.420 0.32 225 90 FLEETWOOD ALUMINUM Zn I Mstr.Bdrm, 2 Bdrms 6 Window Right (Southwest) 16.0 0.420 0.32 225 90 FLEETWOOD ALUMINUM Zn I Mstr.Bdrm, 2 Bdrms 7 Window Right (Southwest) 16_0 0.420 --Q-a2 225 90 FLEETWOOD ALUMINUM Zn I Mstr.Bdrm 2 Bdrms 8 Window RightSouthwest) 10.0 0.440 0.29 225 90 FLEETWOOD ALUMINUM Zn I Mstr.Bdrm, 2 Bdrms 9 Window Right_(Southwest) 100 0.400 0_39 -225 90 FLEETWOOD ALUMINUM Zn I Mstr.Bdrm, 2 Bdrms_ 10 Window Right -(Southwest) 9_0 0.4000 39 225 90 FLEETWOOD ALUMINUM Zn I Mstr.Bdrm 2 Bdrms 11 Window Right (Southwest) 15.0 0.500 0.30 225 90 FLEETWOOD ALUMINUM Zn I Mstr.Bdrm. 2 Bdrms 12 Window Right (Southwest) _ 15.0 0.500 0.30 225 90 FLEETWOOD ALUMINUM Zn I Mstr.Bdrm, 2 Bdrms 13 Window Rear_(.South) _2.4.0_ 0.400- 0.39 1.80_ _90 FLEE_TW__QQD_ALUM.I.NUM _Zn_I_Mstr,Bd.rm.,_2_Sd.rms_ 14 Window Rear (Southeast) 60.0 0.450 0.35 135 90 FLEETWOOD ALUMINUM Zn I Mstr.Bdrm, 2 Bdrms 15 Window Left East _ 24.0 0.400 0.39 90 90 FLEETWOOD ALUMINUM Zn I Mstr.Bdrm, 2 Bdrms 16 Window Rear (Southeast) 2.2 0.400 0.39 135 90 FLEETWOOD ALUMINUM Zn I Mstr.Bdrm, 2 Bdrms 17 Window Rear (Southeast) 2.2 0.400 0.39 135 90 FLEETWOOD ALUMINUM Zn I Mstr.Bdrm, 2 Bdrms 18 Window Rear Southeast) 2.2 0.400 0.39 135 90 FLEETWOOD ALUMINUM Zn I Mstr.Bdrm, 2 Bdrms 19 Window Right_(.Southwest) 80_0 0.450 ---Q.35 225 90 FLEETWOOD ALUMINUM Zn II HallLvng GrtRm 20 Window Rear (Southeast) 12800 0.450 0.35 135 90 FLEETWOOD ALUMINUM Zn II Hall,Lvng,GrtRm 21 Window Front (Northwest) 28.0 0.440 0.29 315 90 FLEETWOOD ALUMINUM Zn II HaII,Lvng,GrtRm .22. Window Front (Northwest) 96.0 0.450 0.35 315 90 FLEETWOOD ALUMINUM Zn II Hall .Lvng,GrtRm 23 Window Right (Southwest) _4.0_0 0.440 0.29 225 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng,Nk 24 Window Front (Northwest) 2.2 0.440 0.29 315 90 FLEETWOOD ALUMINUM Zn III Bdrms Dnng,Nk 25 Window Front Northwest) 2.2 0.440 0.29 315 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng,Nk 26 Window Left (Northeast) 2.2 0.400 0.39 45 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng,Nk 27 Window Left (Northeast) 2.2 0.400 0.39 45 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng,Nk 28 Window Left (Northeast) 2.2 0.400 0.39 45 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng,Nk 29 Window Rear (Southeast) 20.0 0.400 0.39 135 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng,Nk INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 _ 6 Bug Screen 0.76 _ 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 B�cu Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 8.0 3.0 _ 6.0 0.1 6.0 6.0 14 Bug Screen 0.76 10.0 6.0_ 6.0 0.1 6.0 6.0 15 Bug Screen 0.76 8.0 3.0 6.0 0.1 6.0 6.0 16 Bug Screen 0.76 1.5 1.5 15.5 0.1 2.0 2.0 17 Bug Screen 0.76 1.5 1.5 15.5 0.1 2.0 2.0 18 Bug Screen 0.76 1.5 1.5 15.5 0.1 2.0 2.0 19 Bug Screen 0.76 8.0 8.0 15.0 0.1 2.0 2.0 20 Bug Screen 0.76 10.0 16.0 13.0 0.1 2.0 2.0 21 Bug Screen 0.76 8.0 3.5 11.0 0.1 2.0 2.0 22 Bug Screen 0.76 8.0 12.0 4.5 0.1 4.0 4.0 23 Bug Screen _ 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 _ 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 1.6 1.6 __ 2.5 0.1 2.0 2.0 _ I EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page:11 of 17 I Computer Method Summary (Part 2 of 3) C -2R CHRIS HARRIS 1/27/2005 Project Title Date FENESTRATION SURFACES U_ Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments _3.0. 31 Window -Left -(Northeast) Window Rear (Southeast) 32 Window Rear (Southeast) 33 Window Left Northeast) 34 Window Left (Northeast) 35 Window Left (Northeast) 36 Window Left_(Northeast) 37 Window Rear (Southeast) 38 Window Rear (Southeast) 39 Window Rear (Southeast) 40 Window Left (East)_ 41 Window Rear (Southeast) _4.2 43 Window Rear_(.South.) Window Right (Southwest) 0.39 135 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng,Nk _2.2 2 0.400 0 39 135 90 FLEETWOOD ALUMINUM Zn III Bdrms Dnng,Nk 2.2 0.400 __k39 135 _ 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng,Nk 17_5 0.400 0.39 90 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng,Nk 42.0 0.400 0.39 135 _ 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng. Nk -J-7..5- 0._400_ ___0.39 1.80_ _90 FLEETW00D ALUM.I.N M Zn_I.I.I_Bdrms.,Dn. ng,Nk 24_1 _ 0.400 0.39 _ 225 90 FLEETWOOD ALUMINUM Zn III Bdrms.Dnng,Nk 1.6.0_ _0.420_ -.-0.32. 4.5_ _9.0. FLEE.T_W_ _OOD ALUMINUM _Zn_I.II_B.drms,Dnng,Nk _16.0 0.420 _ 0.32 135_ 90 FLEETWOOD ALUMINUM Zn III Bdrms.Dnng,Nk 48.0 0.450 0.35 135 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng,Nk 8.0 0.400 0.39 45 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng,Nk _ 2_2 0.400 _ 0.39 45 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng,Nk 2.2 0.400 0.39 45 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng,Nk _2.2 0.400_ 0 39 4590 FLEETWOOD ALUMINUM Zn III Bdrms,Dnna,Nk 16.0 0.400 0.39 135 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng,Nk _2.2 2 0.400 0 39 135 90 FLEETWOOD ALUMINUM Zn III Bdrms Dnng,Nk 2.2 0.400 __k39 135 _ 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng,Nk 17_5 0.400 0.39 90 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng,Nk 42.0 0.400 0.39 135 _ 90 FLEETWOOD ALUMINUM Zn III Bdrms,Dnng. Nk -J-7..5- 0._400_ ___0.39 1.80_ _90 FLEETW00D ALUM.I.N M Zn_I.I.I_Bdrms.,Dn. ng,Nk 24_1 _ 0.400 0.39 _ 225 90 FLEETWOOD ALUMINUM Zn III Bdrms.Dnng,Nk INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen _ 0.76 36 Bug Screen 0.76 37 Bu Screen n 7a 38 39 40 41 42 43 9 Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen 0.76 Left Fin Right Fin 0.76 0.76 7.0 2.5 4.5 0.1 4.0 4.0 0.76 7.0 6.0 _ 4.5 Overhang Window 4.0 Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 8.0 _ 6.0 4.0 0.1 4.0 4.0 8.0 8.0 19.0 0.1 0.0 0.0 8.0 2.5 19.0 0.1 0.0 0.0 8.0 1.5 15.2 0.1 2.0 2.0 8_0 8 0 _j_5_2 0 1 _ 2_0 2.0 8.0 4.4 8.0 0.1 8.0 8.0 0.76 0.76 0.76 7.0 2.5 4.5 0.1 4.0 4.0 0.76 7.0 6.0 _ 4.5 0.1 4.0 4.0 0.76 7.0 _ 2.5 4.5 0.1 4.0 4.0 0.76 9.7 2.5 4.5 0.1 4.0 _ 4.0 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Pape: 12 of 17 Computer Method Summary Minimum (Part 3 of 3) C -2R Insulation Type CHRIS HARRIS Factor R -Val. Depth 1/27/2005 Project Title 226 0.760 Date THERMAL MASS FOR HIGH MASS DESIGN Slab_P_erimeter 76 0.7.6 Area Thick. Heat ZoJ.I_Hall,Lvng.,GrtR-m Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heavyweight _2,49.9. _3..5.0 _28. _0..98. n/a _2. Zn_I_Mstr..B.drm,2_B.drms_/_S.lab_onGrade Concrete. Heavyweight 1,679 3`50 28 0_98 n/a 0 Zn II Hall.Lvng,GrtRm / Slab on Grade Concrete, Heavyweight 1,700 3 50 28 0_9a n/a 0 Zn III Bdrms,Dnna Nk / Slab on Grade Concrete. Heavyweight 555 3_50 28 0_98 n/a 2 Zn III Bdrms Dnng,Nk / Slab on Grade WATER HEATING SYSTEMS PERIMETER LOSSES HVAC SYSTEMS Heating Equipment Minimum F2 Insulation Type Length Factor R -Val. Depth Location / Comments 81ab Perimeter 226 0.760 0 0 Zn I Mstr_Bdrm 2 Bdrms Slab_P_erimeter 76 0.7.6 0...0. 0 ZoJ.I_Hall,Lvng.,GrtR-m Slab Perimeter 175 --Q-.7-6 20 0 Zn III Bdrms Dnng,Nk Slab_Pedrneter —28. _01-6. 0.0 —0 Zn_I.I.I_Bdrms.,Dn.ng,Nk HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 8U AFUE DuctsinAttic 4.2 Setback HVAC Syst. Zone I Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC Syst. Zone II Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC Syst. Zone III Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Air Conditioner 12.0 SEER DuctsinAttic 4.2 Setback HVAC Sy_st. Zone I Split Air Conditioner 12.2 SEER Ducts in Attic 4.2 Setback HVAC Syst. Zone II Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC Syst. Zone III WATER HEATING SYSTEMS Ratedl Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type TypeSyst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.O.Smith FSG -75-230 Small Gas Standard 2 75 000 74 0.4a n/a 12 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMAR Computer Method Summary (Addendum) C -2R CHRIS HARRIS 1/27/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "A.O.Smith FSG -75-230" Energy Factor = 0.480. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC Syst. Zone I " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2499 sqft Covered Slab Floor, 3.50" thick at Zn I Mstr. Bdrms, Bdrms 4&5 The HVAC System "HVAC Syst. Zone II " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1679 sqft Exposed Slab Floor, 3.50" thick at Zn II Hall, Lvng,GreatRm The HVAC System "HVAC Syst. Zone III " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1700 sqft Exposed Slab Floor, 3.50" thick at Zn III Bdrms,Dnng,Nook HIGH MASS Design(see C -21R) - Verify Thermal Mass: 555 sqft Covered Slab Floor, 3.50" thick at Zn III Bdrms,Dnng,Nook HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS v..... . . n- ..uw 1-1 nwm .—M ... —11 L.— ..— YG11 nLia LIV11 011V u14911VaL16 LCSuny VI 11105C f11b'ab UnIb on a Torm I Plan I Field Run Initiation Time: 01/27/05 16:50:54 Run Code: 1106873454 EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page: 14 of 17 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME CHRIS HARRIS DATE 1/27/2005 SYSTEM NAME HVAC Syst. Zone 1 FLOOR AREA 2,499 ENGINEERING CHECKS Number of Systems 1; ISYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK ;CFM !Sensible Latent CFM Sensible Total Room Loads 1,132 21,972 1,162 760 23,802 Return Vented Lighting 0 Return Air Ducts 1,099 1,190 Return Fan 01 0 Ventilation 01 0 0 0 0 Supply Fan 0 0 Supply Air Ducts 1,099 1,190 TOTAL SYSTEM LOAD 1 24,16911,162, 26,183 Heating System Output per System 65,000,1 Total Output (Btuh) _ 65,00001 Output (Btuh/sgft) 26.0 Cooling System Output per System 58,500 Total Output (Btuh) 58,500 Total Output (Tons) I 4.9 Total Output (Btuh/sqft) 23.4 _I Total Output (sgft/Ton) 512,7 Air System HVAC EQUIPMENT SELECTION CFM per System 2,000 York H4DH060/PDHUCO20L60 U&H 41,025 12,664 65,000 Total Adjusted System Output 41,025 12,664 65,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Airflow (cfm) 2,000 Airflow (cfmisqft) 0.80 Airflow (cfmlTon) 410.3 Outside Air (%) 0.0 Outside Air (cfm/sqft) _ 0.00 _ Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.4 of 69.4 of 100.0 °F O 4S Supply Air Ducts Outside Air 0 cfm 99 4 of Supply Fan Heating Coil 2000 cfm ROOMS 69.4 of 70.0 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6OF 80.5/66.7OF 80.5/66.7°F 61.2/60.1OF O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 61.8 / 60.3 of 2000 cfm 49.7% R.H. ROOMS 80.5 / 66.7 °F 80.0 / 66.5 of Return Air Ducts I EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page. 15 of 17 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE CHRIS HARRIS 1/27/2005 SYSTEM NAME FLOOR AREA HVAC Syst. Zone II 1,679 Number of Systems 1 Heating System Output per System 64,000 Total Output (Btuh) 64,000 Output (Btuh/sgft) 38.1 Cooling System Output per System 48,000 Total Output (Btuh) 48,000 Total Output (Tons) 4.0 Total Output (Btuh/sqft) 28.6 Total Output (sgfUTon) 419.8 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sgft) 0.95 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.01 Outside Air (cfm/sgft) 0.00) Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 1 COIL HTG. PEAK CFM Sensible Latent CFM Sensible 633 15,241781 337 13,190 0 762 660 0 0 0 0 0 0 0 0 0 762 660 16,765 781 York H4DH048/P4HUB16L064 U&H 40,077 2,182 Total Adjusted System Output 40,077 2,182 i (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm 14,509 64,000 64,000 Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 69.6 of 69.6 of 107.2 of O Supply Air Ducts Outside Air 0 cfm 106.8 of Supply Fan Heating Coil 1600 cfm ROOMS] 70.0 of 69.6 of k Return Air Ducts 4 (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) 111.0 / 77.6 OF 80.4 / 64.10 80.4 / 64.1oF . 56.9 / 55.6 of Outside Air 0 cfm 80.4/64.10F Supply Fan Cooling Coil 1600 cfm Return Air Ducts Supply Alr Ducts 57.4 / 55.7 of 41.7% R.H. ROOMS 80.0 / 64.0 of EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page: 16 of 17� 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE CHRIS HARRIS 1/27/2005 SYSTEM NAME FLOOR AREA HVAC Syst. Zone III 2,255 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAKCOIL HTG. PEAK CFM Sensible Latent CFM Sensible 21,066 1,048 York H4DH060/PDHUCO20L60 U&H 41,052 12,564 Total Adjusted System Output I 41,0521 12,564 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatina Peakl 26.0 OF 69.5 OF 69.5 OF ® 100.0 °F Outside Air 0 cfm 69.5 OF 102 Supply Fan Heating Coil 2000 cfm �% Return Air Ducts 4 24,894 65,000 65,000 Jan 12 ann Supply Air Ducts 99.5 OF ROOMS 70.0 OF (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) I 111.0/77.6°F 80.4/66.6°F 80.4/66.6°F . 61.2/60.0°F r1 Outside Air 0 cfm 80.4/66.6 °F Supply Fan Cooling Coil 2000 cfm Return Air Ducts Supply Air Ducts 61.6 / 60.2 of 49.5% R.H. ROOMS 80.0 / 66.4 OF EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page: 17 of 17 78-495 CALLE TAMPICO haw LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BRES2017-0181 Property Address: 53395 VIA STRADA APN: 777200001 Application Description: GLADNEY / ADD BATHROOM AT EXISTING OFFICE Property Zoning: Application Valuation: $25,000.00 Applicant: D ANTON MARINKOVICH 550 S OLEANDER RD AUG 0 8 2011 DD PALM SPRINGS, CA 92264 CITY CP LA QUINTA DESIGN AND DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B. C54 License No.: 655 [ � Date: `� " � ' (� Cdntr� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects' the applicant to a civil penalty of not more than five hundred dollars ($500).: ( 11, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). I 11, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_J I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/8/2017 Owner: DAN AND DIANE GLADNEY 53395 VIA STRADA LA QUINTA, CA 92253 Contractor: GALATI ENTERPRISES INC 78050 CALLE CADIZ LA QUINTA, CA 92253 (760)777-9994 Llc. No.: 655861 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance ofwork for which this permit is issued. 1 1 have and will maintain workers' compensation insurance, as required by Secti 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: BENCHMARK INSURANCE COMPANY Policy Number: CST5009259 _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. l)ate:.o� WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes. �/�I1N11r�.W11���Af1,,�1 Raro•� �� � ` 1 �ao��r��ro le.,.,�ir•�r,r �r eao.,r1•Wt t�'�/ lI Date: 8/8/2017 Application Number: BRES2017-0181 Owner: Property Address: 53395 VIA STRADA DAN AND DIANE GLADNEY APN: 777200001 53395 VIA STRADA Application Description: GLADNEY / ADD BATHROOM AT EXISTING OFFICE LA QUINTA, CA 92253 Property Zoning: Application Valuation: $25,000.00 Applicant: Contractor: , ANTON MARINKOVICH GALATI ENTERPRISES INC 550 S OLEANDER RD 78050 CALLE CADIZ PALM SPRINGS, CA 92264 LA QUINTA, CA 92253 (760)777-9994 ------7------------------------------------------------------------------------------------- Llc. No.: 655861 Detail: GLADNEY / ADD BATHROOM TO EXISTING OFFICE RESULTING IN AN ADDITION OF 17 S.F OF CONDITIONED SPACE. SITE SPECIFIC ENGINEERING (B.G. STRUCTURAL ENGINEERING). WORK FULLY COMPLETED PRIOR TO PERMIT ISSUANCE --CONTRACTOR TO EXPOSE CONSTRUCTION FOR INSPECTION AS NECESSARY. 2016 CALIFORNIA BUILDING CODES. ar- INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF 101-0000-42400 0 $127.68 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF PC 101-0000-42600 0 $179.36 • Total Paid for ADDITION: $307.04 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING. STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $25.33 Total Paid for ELECTRICAL: $50.66 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN 101-0000-42402 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN PC 101-0000-42600 0 $5.07 Total Paid for MECHANICAL: $17.74 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $38.01 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $38.01 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.67:77J Total Paid for PLUMBING FEES: $101.36 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 100 SF 101-0000-42400 0 $51.68 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 0 $141.36 Total Paid for REMODEL: $193.04 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $3.25 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $3.25 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 TOTALS:•• Bin # City of La Quinta -Building 8L Safety Division 78-495 Calle Tampico. La Quinta, CA 92253- (760) 777-7012 d' &8/ Building Permit A lication and Tracking pP g Sheet , Permit # ,,%NA— Project Address: 5-53,7.5— Owner's Name: h �� A. P- Number: 1 . ) Address: Jf -3�;T--• U/4 Legal Description: City, ST, Zip: Contractor: TelePhone: 7v• ��/ / Z `'?'`'•`v'` Address: 7S-Zj cgez_ C.A7Z Project Description:S �J /LT City, ST, Zip:, U/ ele hn- Telephone: 777, 2YE11 _ d s^N. �S7ytib . 7 State State Lic. # : City Lic. M Arch., Engr., Designer. Address: 7S-/%s— City, ST, Zip:. Plie-/t'1 /� Telephone• ::.. ;:.:.;:.::•<;r •7�li7�,�p�j• $�— -� •-f:->:»-:.>:.>�•:?�: " '... >30 ....State Lic. #: :. Name of Contact Person: N 1-J1%A1Nl;Ujf14j Construction Type: Occupancy: Project type (circle one): New dd'n Alter Repair Demo Sq. Ft.: # Stories: # Units: Telephone # of Contact Person:(oO . S67-,39K--/ Estimated Value of Project: $— 000 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for correctionsfissue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A: Approval Plans resubmitted Grading IN HOUSE: '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees lg:n u � Total Permit ees JUL. 2 5 2017 CITY OF L4 ®UINTA COMMUNITY DEVELOPMENT 4 Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) �VCETVEU 98-1224 AUG 0 8 2017 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: I COMM/IND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS CITY OF LA QUINTA COMMUNITY DEVELOPMENT CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: jThe Hidea Owner's Name: Dan and Diane Gladney Project Address: 53-395 Via Estrada Project Description: Addition to Existing Dwelling APN: 777200001 Tract #: Date: August 4, 2017 Phone No. 760-777-9994 Lot #'s: Type of Development: Residential XX! Commercial Industrial Total Square Feet of Building Area: 17 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized �o sign opb.ehalf of the owner/developer. Dated: August 4, 2017 Signature: \J SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Note: Number of Sq.Ft. 17 Pursuant to AB 181 any room additions or enclosures of 500 Amount per Sq.Ft. $0.00 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within the same school district's Amount Collected $0.00 jurisdiction are exempt from developer fees. Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Laurie Howard, Secretary Signature: ac {w&A d v - NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:chn�docti'devtces/certiticate of compliance Form updated 3-2007 11/2010