04-6779 (SFD)3ox 1504
5 CALLE TAMPICO
JINTA, CALIFORNIA 92253
�r
Application description
Property Zoning . . . . .
Application valuation . .
BUILDING PERMIT
BUILDING & SAFETY DEPARTMENT
(760).777-7012
FAX (760) 777=7011
INSPECTION REQUESTS (760) 777-7153
04-00006779 Date 3/25/05
53356 VIA STRADA
772-520-053- - -
DWELLING - SINGLE FAMILY DETACHED
LOW DENSITY RESIDENTIAL
565293
Owner
Contractor
------------------------
CHRIS HARRIS
-----------------
HARRIS HOMES INC
2127 PALOS VERDES DR.
N 2127 PALOS VERDES
DRIVE NORTH
LONG BEACH
CA 90807 LOMITA
CA 90717
(310) 325-6355
WCC: STATE FUND
WC: 1773515
01/01/06
CSLB: 231712
04/30/05
CCC: B
------ Structure Information
6391 SQ. FT. SFD
-----
Construction Type . .
. . . TYPE V - NON RATED
Occupancy Type . . .
. . . DWELLG/LODGING/LONG <=10
Flood Zone . . . . .
. . . NON -AO FLOOD ZONE
Other struct info . .
. . . CODE EDITION
2001 CBC
# BEDROOMS
5.00
FIRE SPRINKLERS
NO
GARAGE,SQ FTG
1627.00
PATIO SQ -FTG
1279.00
•NUMBER OF UNITS
1.00
----------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
6391.00
Permit
BUILDING PERMIT
Additional desc
Permit Fee . . . .
2237.50 Plan Check Fee
1454.38
Issue Date . . . .
Valuation . . .
. 565293
Expiration Date
9/25/05
Qty Unit Charge
Per
Extension
BASE FEE
2039.50
66.00 3.0000
----------------------------------------------------------------------------
THOU BLDG 500,001-1,000,000
198.00
Permit . . . . . .
ELEC-NEW RESIDENTIAL
Additional desc
Permit Fee . . . .
286.23 Plan Check Fee
71.56
Issue Date . . . .
Valuation . . .
. 0
Expiration Date
9/25/05'
.Qty Unit Charge
Per
Extension
BASE FEE
% 15.00
6391.00• .0350
ELEC NEW RES - 1 OR 2 FAM;LY
223.69
P.O. BOX 1504 • /i •
w VOICE (760) 777-7012
78-495 CALLE TAMPICO FAX (760) 777-701N
LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT
Tr
Application Number:
Applicant: �� '
Applicant's Mailing Address:
Date:
Architect or Engineer:
Architect or Engineer's Address:
Lic. No.:
t3UILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
Code, and my License i full force and effect. 17/2,License Class License No.
Date 3 aSo Contractor IAV Namers /,iC
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
U 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
U I am exempt under Sec. . BA P.C. for this reason
Date
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My w rkers' compensation insurance carrier and policy number are:
Carrier 57*71F tyAIQ Policy Number / 107 Z
I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with those provisions.
Date <.aplicant
WARNING: FAILURE TO SECURE WORKERS' COMPE SATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name
Lender's Address
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this county to enter up n the above-mentioned property for inspection. purposes.
Date 3 a 5 b5- Signature (Applicant or Agent):
Page
2
Application Number .
. . . 04-00006779 Date
3/25/05
Qty Unit Charge
Per
Extension
1627.00 .0200
ELEC GARAGE OR NON-RESIDENTIAL
32.54
1.00 15.0000
EA ELEC TEMPORARY POWER POLE
15.00
--------------------------
Permit . . . . . .
---------------------------------------
GRADING PERMIT
-----------
Additional desc . .
Permit Fee . . . .
15.00 Plan Check Fee
.00
Issue Date . . . .
Valuation.
0
Expiration Date
9/25/05
Qty Unit Charge
Per
Extension
------------------------------------------------------
BASE FEE
15.00
------------------
Permit MECHANICAL
Additional desc
Permit Fee . . . .
119.50 Plan Check Fee
29.88
Issue Date . . . .
Valuation . . . .
0
Expiration Date
9/25/05
Qty Unit Charge
Per
Extension
BASE FEE
15.00
4.00 9.0.000
EA MECH FURNACE <=100K
36.00
4.00 9.0000
EA MECH B/C <=3HP/100K BTU
36.00
4.00 6.5000
EA MECH VENT FAN
26.00
1.00 6.5000
-----------------------------------.-------------.----
EA MECH EXHAUST HOOD
6.50
------------------------
Permit PLUMBING'
Additional desc
Permit Fee . . . .
237.75 Plan Check Fee
59.44
Issue Date
Valuation
0
Expiration Date
9/25/05
Qty Unit Charge
Per
Extension
BASE FEE
15.00
26.0.0 6.0000
EA PLB FIXTURE
156.00
1.00 15.0000
EA PLB BUILDING SEWER
15.00
2.00 7.5000
EA PLB WATER HEATER/VENT
15.00
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00 9.0000
EA PLB LAWN SPRINKLER SYSTEM
9.00
13.00 .7500.
EA PLB GAS PIPE >=5.
9.75
1.00 15.0000
----------------------------------------------------------------------------
EA PLB GAS METER
15.00
Special Notes and Comments
6391 SQ. FT. SFD THIS
PERMIT DOES NOT
INCLUDE POOL & SPA BLOCK WALLS OR
Page 3
Application Number
. . . . .
04-00006779 Date
3/25/05
----------------------------------------------------------------------------
Special Notes and
Comments
DRIVEWAY APPROACH.
11/9/04 8:09:20
AM
JJOHNSON
----------------- ---------------------------------------------------------
.Other Fees . . .
. . . . . .
ART IN PUBLIC PLACES -RES
913.23
DIF COMMUNITY CENTERS -RES,
97.00
,DIF CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE
145.44
DIF FIRE PROTECTION -RES
97.00
GRADING PLAN CHECK FEE
00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
5.00
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI) - RES
56.52
DIF STREET MAINT FAC -RES
15.00
DIF TRANSPORTATION - RES
1098.00
Fee summary
-----------------
Charged
Paid Credited
Due
Permit Fee Total
-7--7 -----
2895.98
-------------- ------ ----------
.00 .00
2895.98
Plan Check Total
1615.26
1000.00 .00
615.26-
15.26Other
OtherFee Total
3520.19
-.00 .00
3520.19
Grand Total
8031.43
1000.00 .00
7031.43
wilding ? y
ddress
P.O. BOX 1504 APPLICATION ONLY
78-495 CALLE TAMPICO
�' L .-P{i LA QUINTA, CALIFORNIA 92253
uwneerr /
Gil il,67
Mailing )
Address /!i 1/L-7 N
City Zip I
LaM (Tih . 4,4k a1 D 7 �►�) 3x5.103
Address
City lZip JTel.
State Lic. (City
& Classif. Lic. #
signer'..'( �V J C% Wf /,W&t� -,:WM E0 I
Ad ress - I Tel
7� • 854- v�C �► i� 4 4.0 •3 28
�,ft r�LI IState
y]M_"•�((p/i��A� 7v�7vw.�/ylLic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and
effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a
permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes-
sions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon and who does such work himself or through his own employees, provided
that such improvements are not intended or offered for sale. If, however, the building or im-
provement is sold within one year of completion, the owner -builder will have the burden of
proving that he did not build or improve for the purpose of sale).
❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct
the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does
not apply to an owner of property who builds or improves thereon, and who contracts for such
projects with a contractor(s) licensed pursuant to the Contractor's License Law)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑ Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less).
I certify that in the performance of the work for which this Permit is issued, I shall not
employ any person in any manner so as to become subject to Workers' Compensation Laws of
California.
Date Owner
NOTICE TO APPLICANT.. If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work
for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
WHITE = BUILDING DEPARTMENT
BUILDING: TYPE CONSTV•, 4fk OCCP.
C.. GR
A.P. Number r. 7►' E7 A/ �✓ Q�
Legal Description
Projectescription --o-:21KWE 4 �v(0L�v W*TO
ZONE: BY: It
Minimum Setback Distances: dl11,
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by:—
Validated by:
Validation:
YELLOW = APPLICANT
Date Permit
PINK = FINANCE
Sq. Ft. .y,� `
Size t 1
No. 1 No. Dw. '
Stories l Units
NewX Add ❑ Alter ❑ Repair ❑
Demolition ❑
3 10 - %0-
S7-/ YV Glez�
310 - 31� &39V WK. XA10
Estimated Valuation
PERMIT
AMOUNT
Plan Chk. Dep.
QQ
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
f .
S.M.I.
Grading
Driveway Eno.
f U I
Infrastructure
) 1_
104 ;' '-/f j
Q11 r
ur
TOTAL
REMARKS
A i l A •i As
U
4e +
ZONE: BY: It
Minimum Setback Distances: dl11,
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by:—
Validated by:
Validation:
YELLOW = APPLICANT
Date Permit
PINK = FINANCE
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 – Fax (760) 398-1224
Project Name:
Owner's Name:
Chris Harris
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMMIIND. AMOUNT:
DATE:
RECEIPT:
CHECK#:
INITIALS:
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Address: 53-356 Via Strada, La Quinta, CA 92253
Project Description: Single Family Home
APN: 772 520 053 t#: 0
Type of Development: esidential . xx Commercial
Total Square Feet of Building Area: 6391
Date: 3/17/05
Phone No. 310 466 5440
Lot #'s: a l0
Industrial
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer.
Dated: 3b 171 DS- Signature:
***************************************************b*-******************
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code
17620
Number of Sq.Ft.
Amount per Sq.Ft.
Amount Collected
Gov. Code
65995
6391
$2.68
$17,127.88
Building Permit Application Completed: Yes/No
Project Agreement Existing Not Subject to Fee
Approval Prior to 1/1/87 Requirement
By: Carey M. Carlson, Asst. Supt., Business Services
Certificate issued by: Marcela Valdez, Facilities Secretary Signature:
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1)aiv itten notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest Imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject
of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance.
N.-IV:c/mydocs,'devfces/certificate of compliance form tables f0 USEs.doc 1/16/03 T
W EDDLE
SURVEYING MAPPING, INC.
Boundary • Construction • Topographic • Aerial Surveys • ALTA Surveys • GPS • Consulting
May 18, 2005 53-36 � �i,, 9wt*�
Mr. Timothy R. Jonasson
Public Works Director / City Engineer
City of La Quinta
78-495 Calle Tampico
La Quinta, CA 92253-1504
Re: Pad/Form Grade Verification
City of La Quinta
Lot 269 Tract No. 29894-2 Amended
THE HIDEAWAY
APN 772-520-053
Dear Mr. Jonasson:
We have performed a field survey to determine the vertical location of the building pad
and form for the above referenced project. The elevation's observed are as follows:
PAD (DESIGN) PAD (AS -BUILT)
1012.80 1012.8
FORM (DESIGN) FORM (AS -BUILT)
1013.55 1013.57
These field observations are in substantial conformance with the precise grading plan
prepared by McGLOIN ENGINEERING, dated 10/09/2004 and the building horizontal
location substantially conforms to the required setbacks and site layout as shown on the
approved site plan.
Sincerely,
WEDDLE SURVEYING MAPPING, INC. \_NND 9U,
U r O
NO. 5570 m
David L. Weddle, President �c EXP. 09/30/05
L.S. 5570, Exp 9/30/05 OF CALF
P.O. Boz 10418 • Palm Desert, CA 92255-0418
73-960 Hwy. 111, Ste. 6 • Palm Desert, CA 92260 • 760.346.3748
E -Mail: WedSury@aol.com • Fax 760.346.3 749
r
Certificate' of Occupancy
5 V
4
�lG`'� Lac_•-cnro
OF IBuilding & Safety Department
This Certificate is issued pursuant to the requirements of Section 109 of the California Building
Code, certifying that, at the time of issuance, this structure was in compliance with the
provisions of the Building Code and the various ordinances of the City regulating building
construction and/or use.
BUILDING ADDRESS: 53356 VIA STRADA
Use classification: SFD Building Permit No.: 04-7669
Occupancy Group: R3 Type of Construction: VN Land Use Zone: RL
Owner of Building: CHRIS HARRIS Address: 2127 PALOS VERDES DR. N
City, ST, ZIP: LONG BEACH CA 90807
By: STEPHEN WHITTLET
�- Date: 3-31-06
Building Offici
POST IN A CONSPICUOUS PLACE Al
11
1
,- A,
I TITLE 24 REPORT
Title 24 Report for:
CHRIS HARRIS
LA Q U I N TA, CA
Project Designer:
CHRIS HARRIS
LA QUINTA, CA
CITY OF LQ
repared By:
BUILDING & S
APP(ANA
GIL
FOR CONS
Group
oA 6erf,
e Way, Suite 5
CA 92260
340-3528
Job Number:
ADY91-1004
pS Date:
1/27/2005
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC (415) 883-5900.
EnergyPro 3.1 By EnergySoft Job Number: ADY91-1004 User Number: 5553 1
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
CHRIS HARRIS 1/27/2005
Project Title Date
LA QUINTA
Project Address Building Permit #
GLS Group (760) 340-3528 Plan Check / Date
Documentation Author Telephone
Computer Performance 15 Field Check I Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 6,433 ft2 Average Ceiling Height: 11.9 ft
Total Conditioned Slab Area: 6,433 ft2
Building Type:
Frame
Type
(check one or more)
R-38 Roof (R.38.2x4.24)
Single Family Detached
❑ Addition
❑ Single Family Attached
❑ Existing Building
❑ Multi -Family
❑ Existing Plus Addition
Front Orientation: (Northwest)
315 deq Floor Construction Type: ® Slab Floor
Number of Dwelling Units:
1.00
Number of Stories:
1 ❑ Raised Floor
Component
Type
Frame
Type
Const.
Assembly
U -Value
R-38 Roof (R.38.2x4.24)
Wood
0.024
Slab On Grade
n/a
0.756
R-19 Wall w/1" EPS
Wood
0.045
Solid Wood Door
None
0.387
Slab On Grade
n/a
0.756
FENESTRATION
Location/Comments
(attic, garage, typical, etc.)
Exterior Roof
Covered Slab w/R-0.0 Perimeter Insulation
Exterior Wall
Exterior Door
Exposed Slab w/R-0.0 Perimeter Insulation
Shadina Devices
Type
Orientation
Area
SF
U -Factor
Fenestration
SHGC
Exterior
Shading
Overhang Side Fins
Yes / No Yes / No
Left
(Northeast)
42.0
0.42
0.32
Bug Screen
❑
X❑
❑
Front
(Northwest)
42.0
0.42
0.32
Bug Screen
❑
X❑
❑
X❑
Front
(Northwest)
3.2
0.40
0.39
Bug Screen
❑
❑
Right
(Southwest)
66.0
0.42
0.32
Bug Screen
❑
X❑
❑
X❑
Right
(Southwest)
50.0
0.44
0.29
Bug Screen
❑
❑
X❑
Right
(Southwest)
16.0
0.40
0.39
Bug Screen
❑
X❑
❑
X❑
Right
(Southwest)
30.0
0.50
0.30
Bug Screen
❑
x❑
❑
x❑
Rear
(South)
41.5
0.40
0.39
Bug Screen
X❑
❑
❑
x❑
Rear
(Southeast)
236.0
0.45
0.35
Bug Screen
x❑
❑
❑
Q
Left
(East)
41.5
0.40
0.39
Bug Screen
X❑
❑
❑
0
Rear
(Southeast)
84.8
0.40
0.39
Bug Screen
x❑
❑
❑
X❑
Right
(Southwest)
80.0
0.45
0.35
Bug Screen
X❑
❑
❑X❑
Run Initiation
Time: 01/27/05
16:50:54 Run Code: 1106873454
Ener
Pro 3.1 By Ener
Soft
User Number: 5553
Job Number: ADY91-1004
Pa e:3
of 17
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
CHRIS HARRIS 1/27/2005
Project Title Date
LA QUINTA
Project Address Building Permit #
GLS Group (760) 340-3528 Plan Check / Date
Documentation Author Telephone
Computer Performance 15 Field Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 6,433 ft2 Average Ceiling Height: 11.9 ft
Total Conditioned Slab Area: 6,433 ft2
Building Type:
(check one or more)
X❑ Single Family Detached ❑ Addition
❑ Single Family Attached ❑ Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: (Northwest) 315 deq
Number of Dwelling Units: 1.00
Number of Stories: 1
BUILDING SHELL INSULATION
Floor Construction Type: ® Slab Floor
❑ Raised Floor
Const.
Component Frame Assembly Location/Comments
Type Type U -Value (attic, garage, typical, etc.)
FENESTRATION Shadina Devices
Type
Orientation
Area
Fenestration
Exterior
Overhang Side Fins
SF
U -Factor
SHGC
Shading
Yes / No
Yes / No
Front
(Northwest)
28.0
0.44
0.29
Bug Screen
x❑
❑
❑ x❑
Front
(Northwest)
96.0
0.45
0.35
Bug Screen
x❑
❑
❑ X❑
Front
(Northwest)
4.4
0.44
0.29
Bug Screen
❑X❑
❑x❑
Left
(Northeast)
11.2
0.40
0.39
Bug Screen
❑
❑ Q
Left
(Northeast)
16.0
0.42
0.32
Bug Screen
191
❑
❑
Rear
(Southeast)
16.0
0.42
0.32
Bug Screen[R]
❑
❑ o
Left
(Northeast)
10.2
0.40
0.39
Bug Screen
X❑
❑
❑ x❑
Rear
(Southeast)
4.5
0.40
0.39
Bug Screen
❑
o
❑ o
Right
(Southwest)
24.1
0.40
0.39
Bug ScreenX❑
❑
❑X❑
❑
❑
❑ ❑
❑
❑
❑ ❑
Run Initiation Time: 01/27/05 16:50:54 Run Code: 1106873454
Ener
Pro 3.1 By Ener
Soft
User Number: 5553
Job Number: ADY91-1004
Pa e:4 of 17
Certificate of Compliance: Residential
(Part 2 of 2) CF -1 R
CHRIS HARRIS
1/27/2005
Project Title
Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment
Minimum
Type and
Duct or
Type (furnace, heat
Efficiency
Location
Piping
Thermostat Location /
pump, etc.)
(AFUE/HSPF)(ducts, attic, etc.)
R -Value
Type Comments
Central Furnace
80% AFUE
Ducts in Attic
4.2 Setback— HVAC Syst- Zone I
f entmi Furnace
80% AFUE
bunts in Attic
42
Setback HVAC Syst. Zone II
Central Furnace
80% AFUE
Ducts in Attic
4.2
Setback HVAC Syst. Zone III
Cooling Equipment
Minimum
Duct
Type (air conditioner,
Efficiency
Location
Duct
Thermostat Location /
heat pump, evap. cooling) (SEER)
(attic, etc.)
R -Value
Type Comments
Split Air Conditioner
12.0 SEER
Ducts in Attic
42 Setback_ HVAC Sy. -;t lone I
Split Air Conditioner
12„2 ,';FFR
Ducts in Attic
42
Setback HVAC Syst Zone II
Split Air Conditioner
12.0 SEER
Ducts in Attic
4.2
Setback HVAC Syst- Zone III
WATER HEATING SYSTEMS
Rated 1
Tank Energy Fact! 1 External
Water Heater
Water Heater
Distribution # in
Input
Cap. or Recovery Standby Tank Insul.
System Name
Type
Type Syst.
Btu/hr
(gal) Efficiency Loss (%) R -Value
A.O.Smith FSG -75-230
Small Gas Standard 2—
75,000
74 0.48 n/a 12
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
GOMPLIANCE 5TATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design respoppibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
an ' verificatio y an approved HERS rater.
eSl r OrIfir (per Business 8 Professions Code)
ame:� '
Title/Firm: cL4S HARRIS
Address:
LA QUINTA, CA
Telepho e:
Lic. #:
(sign ure) (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
Documentation Author
Name: ADRIANA GIL
Title/Firm: GLS Group
Address: 74-854 Velie Way, Suite 5
Palm Desert, CA 92260
Telephon : (760) 340-3528
G
,11 VIA
(signature) (date)
natu
IEnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page:5 of 17 1
Certificate of Compliance: Residential (Addendum) CF -1 R
CHRIS HARRIS 1/27/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. Plan Field
The DHW System "A.O.Smith FSG -75-230" Energy Factor = 0.480. An EF below 0.58 requires an R-12 External Blanket.
The HVAC System "HVAC Syst. Zone I " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2499 sqft Covered Slab Floor, 3.50" thick at Zn I Mstr. Bdrms, Bdrms 4&5
The HVAC System "HVAC Syst. Zone II " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1679 sqft Exposed Slab Floor, 3.50" thick at Zn II Hall, Lvng,GreatRm
The HVAC System "HVAC Syst. Zone III " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -21R) - Verify Thermal Mass: 1700 sqft Exposed Slab Floor, 3.50" thick at Zn III Bdrms,Dnng,Nook
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 555 sqft Covered Slab Floor, 3.50" thick at Zn III Bdrms,Dnng,Nook
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
..,... .........— —1.. wo.—. a..0 u.oul— v — Neu v. umc = mcaaufca vn a wnn a.r-ort. I Plan I Field
EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page:6 of 17 1
Mandatory Measures Checklist: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Building Envelope Measures
❑X I150(a): Minimum R-19 ceiling insulation.
❑ §150(b): Loose fill insulation manufacturer's labeled R -Value.
❑*§150c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
X
not apply to exterior mass walls).
❑ '§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.
§150(l): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no
❑
greater than 2.0 perm/inch.
a§118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑ § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
❑%�
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
X§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
X§150(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMACNA or ACCA.
❑X §150(1): Setback thermostat on all applicable heating and/or cooling systems.
§1500): Pipe and Tank Insulation
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page:7 of 17
Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
Al '§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
duct tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of the material.
X❑ § 114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance
heating, and no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or
spas.
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
X] §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
❑ §118 (f): Cool Roof material meet specified criteria
Lighting Measures
§150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved.
3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page:8 of 17
Computer Method Summary (Part 1 of 3) C -2R
CHRI_S_HARRI_S
Act.
1 /_2.7J2QQ5
Project Title
U -Fac.
Azm.
Date
-LA_QU INTA_
-2,499
_0.02.4_
--A-5
1.8_
Project Address
GLS
11_4_
_0..0.4.5.
5.
-45--90-
Building Permit #
-G-coup
4.8.
_0..38.7_
(760)--340-3528
Documentation Author
26
0.045
Telephone
i Plan Check/Date
Com ute._P_erf_or_mance
pr
_0.387_
15
-9-0-
90Wall_
Field Check/Date
Compliance Method (Package or Computer)
_0...0.45_
Climate Zone
-90-
90_Wall_
Source Energy Use
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating
3.30
3.13
0.17
Space Cooling
33.77
29.71
4.06
Domestic Hot Water
4.43
6.56
-2.13
Totals
41.49
39.40
2.09
than Standard:
Total Conditioned Floor Area:
Building Type:
Building Front Orientation:
Number of Dwelling Units;
Number of Stories:
BUILDING ZONE INFORMATION
Zone Name
5.0%
6,433 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor
Single Fam Detached
(Northwest) 315 deg Total Fenestration Area: 14.7%
1.00 Total Conditioned Volume: 76,664 ft'
1 Total Conditioned Slab Area: 6,433 ft 2
# of
Floor Area Volume Units
Zone Type
_HVA_ C_Syst-Zone_I _ 2,4.99 _2.4,992 _0.3.9_ Conditioned_
_FLVP_AC_Syst-Zone_1I_ _ 1.,6.7.9 _24,61.6 _0.26_ -Conditioned-
-H-VA-
onditioned_
JiVA_C_Syst.-Zone-III _ 2,25.5. _22,.0.5.6 _0.25_ Conditioned_
OPAQUE SURFACES
Act.
Type
Area
U -Fac.
Azm.
Tilt
.Roof-
-2,499
_0.02.4_
--A-5
1.8_
Wall-
11_4_
_0..0.4.5.
5.
-45--90-
90_.Door
.Door-
4.8.
_0..38.7_
-45--90-
45__90_Wall-
Wall-
26
0.045
1-35-90
-Door2.4_
_0.387_
1.35
-9-0-
90Wall_
-Wall-
5.5_
_0...0.45_
4.5.
-90-
90_Wall_
-Wall
30
0.0_4.5
135
_90
Wall_
1.8_
0.0_4.5
45
90
Wall_
30_
_0.0.45_
_31.5
-90-
90_Wall-
-Wall
6.0_
_0..04.5_
4.5.
-90-
90_Wall_
-Wall
55_
-0,0-4-5-
31.5
90
Wall_
30_
0,045
45
90
Wall-
28.
_0._04.5_
_31.5.
9.0_
Wall-
3.0_0
045
_225_
--90-
-Wall-
55_
_0...045_
315
9.0_
Wall_
1.0.
_0...0.4.5_
-225_
__9.0_
Wall-
8.7_
_0..04.5_
_31.5.
9A_
Wall_
472.
_0...0.4.5_
-225.
9.0_
Wall-
20
0.0_4.5
31.5
-9-0-
0Wall-
-Wall-
7_1.
-0,0-45-
_225
90
Wal.
20
0045
1.35
90_
Wall_
1.7.2.
_0...0.4.5_
_225.
9.0_
Wall_
33_
_0...0-4.5_
-31.5.
9.0_
Wall_
1.0.6_
_0..0_4.5_
_225.
9.0_
Wall_
26_
_0...0.4.5_
18.0.
9.0_
Wall-
22.
0.0_4.5
135
_ 90_
WaH-
26
0.045
90
_-90_
Wall-
33
0045
4.5
90
Wall-
1.32.
_0.0_4.5
90
90_
Solar
Gains
Y / N Form 3 Reference
_R_38 Roof_(R,38.2x_4..2.4.)
_R_1.9_W a I I_w/_1_E P_S
_Solid_W_ood_Doo.r
. R -1.9_W a I I _w/_1 -"EPS
Solid -Wood -Door
R -1.9_W a l l __w/-1 _ E P_S
. R -1.9_W a l l _w /_1_ E P_S
.R -1.9_W_ _all_w/-1_EP_S
_R-1.9_Wall_w/_L" EP_S
R_19_Wall_w/-1_EP_S
R _1.9_W a l l _w /-1 _ E P_S
_R-1.9_Wall_w/_L" EP_S
RR=19 Wall w/1" EPS
.R-1.9_Wall_w/-L" EPS
R -1.9_W a l l __w/-1 _ EPS
. R A -9_W a I I _w/_1 _ E P_S
_R_1.9_W al I-w/_1_EP_S
R49_Wal1_w/-1 °.EP_S
_R -19_W a I I__w/_1_EPS
_13-1.9_W all_M-1_E S.
_R -1.9_W all_w/_1_E P_S
_R -1.9_W a l l__w/_1-E P_S
RA.9_WaII_w/_11EP_S
.R-1.9_Wall-w/-L" EPS
_R_1.9_W a I I_w/_1_E P_S-
R_-9_Wall w/-1_EP_S
_R -1.9_W all_w/_1_EP-S
R_1.9_W all_w/-1_E P_S
R_19_W_ _all_w/- " EP -S
Thermostat Vent
Type Hgt. Area
-Setback_ 2 _n/a
_S.etb.ack_ 2 _n/.a
_S.etback- 2 _n/a
Location / Comments
.Zn_I_Mstr._B.drm,_2_Bdrms
.Zn_I_Mstr_Bdrm,_2_Bdrms
.Zn-I_Mstr. Bd rm,_2_Bdrms
Zn_I_M str. Bd rm.,_2_Bd rm s
.Zn_I_Mstr B.drm,_2_Bdrms
.Zn_I_M str. Bd rm f2_Bd rms
.Zn_I_M str.. B d rm,_2_Bd rm s
.Zn_I_M str. B d rm,_2_B.drm s
.Zn_I_Mstr..Bd rmr2Bdrms
.Zn_I_Mstr.Bd rmr2Bdrms
.Zn-1_Mstr. Bd rm,2_Bdrms
.Zn_I_M StLBd rm,_2Bdrms
.Zn_I_Mstr_ Bd rm,_2_Bdrms
Zn_I_Mstr_ Bd rm,_2Bdrms
.Zn_I_Mstr._Bd rm,_2_Bdrms
Zn_I_Mstr.. Bd rm,2_Bdrms
.Zn_I-Mstr_ Bdrm,_2_Bdrms
.Zn_I_Mstr-Bdrm,_2_Bdrms
.Zn_I_Mstr. Bd rm,_2Bdrms
.Zn_I_M str_ Bd rm,2Bdrm s
Z n_I_M st r.. B.d rm ,_2_B.d rm s
2n_1_MStr_Bd rm,2Bdrms
.Zn_I_Mstr.. Bdrm,_2_Bdrms
.Z n_I_M str.. Bd rm,_2_Bd rm s
.Zn_I_Mstr_ Bd rm,_2_Bdrms
Z n_I_M str.. Bd rm,_2_B.drm s
Zn_I_Mstr.-Bdrm,_2_8.d rms
.Zn_l_Mstr.Bdrm,_2_Bd rms
Zn_I_M str.. Bd rm,_2Bd rm s
Run Initiation Time: 01127105 16:50:54 Run Code: 1106873454 _I
EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page:9 of 17
Computer Method Summary
Act.
Azm.
Tilt
(Part 1 of 3) C -2R
CHRISJ-�ARRI_S
1.35
0.04.5
1127120-0-5
Project Title
:X
Date
-LA Q_U I_N_- A_
_0._024_
_31.5_
1.8_
Project Address
1 u
Wall-
Building Permit #
GLS Gr_ou.p
-225.
(760) 340-3528
lX
Documentation Author
Wall_
Telephone
Plan Check/Date
Computer_Rer_for_mance
90
15
Field Check/Date
Compliance Method (Package or Computer)
1.88
Climate Zone
-31590
Source Energy Use Standard
Proposed
Compliance
Wall_
(kBtu/sf-yr) Design
Design
Margin
9.0_[X
Space Heating 3.30
3.13
0.17
160
Space Cooling 33.77
29.71
4.06
AXI
Domestic Hot Water 4.43
6.56
-2.13
0.02.4_
Totals 41.49
39.40
2.09
❑
than Standard: 5.0%
Total Conditioned Floor Area: 6,433 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor
Building Type: Single Fam Detached
Building Front Orientation: (Northwest) 315 deg Total Fenestration Area: 14.7%
Number of Dwelling Units: 1.00 Total Conditioned Volume: 76,664 ft'
Number of Stories: 1 Total Conditioned Slab Area: 6,433 ft 2
BUILDING ZONE INFORMATION # of Thermostat Vent
Zone Name Floor Area Volume Units Zone Type Type Hgt. Area
OPAQUE SURFACES
Type Area U -Fac.
Act.
Azm.
Tilt
Solar
Gains
Y / N
Wall_
1.35
0.04.5
135.
90
:X
.Roof
1,679
_0._024_
_31.5_
1.8_
�_
1 u
Wall-
95_
-0...045_
-225.
9.0_
lX
❑
Wall_
215
0945
t35
90
AXI
❑
Wall_
1.88
0.045
-31590
LX
❑
Wall_
7.2.
_0._045_
4.5.
9.0_[X
ID
160
0.0_4.5
_3_1.5
__90
AXI
❑
_Roof
_2,255
0.02.4_
315
18_
LX
❑
Wall_
11.6_
_0...0.4.5_
-225.
9.0_
LX
❑
Wall-
254_
-0..0.4.5_
-31.5_
_9.0_r
LX
1:1_Doo
26
0...387
-315
90.
LX
❑
Wall_
1.0
-0-0-4.5-
45
90
[XI
❑
Wall-
62.
_0..045_
_31.5.
9.0_
❑
Wall -
0_
0.045
-22590
LX
❑
Wall_
122_
0..045_
315
_9.0_
LX
❑
Wall_
x_52.
_0..0.4.5_
-45--90-
LX
❑
Wall-
90_
-0._045_
1.3.5.
9.0_
LX
❑
Wall_
15.8_
_0_0.4.5_
4.5_
_9.0.
LX
❑
Wall-
----104
0.045
-1-3.5--90
[XI
❑
Wall -4_41
00_4.5
45
90
[XI
❑
.Door
51
0.387_
4.5
90
LX
❑
Wall-
82.
_0..0_4.5_
1.35.
9.0_
LX
J
Wall_
8.6_
-0...0_4.5_
-45--90-
LX
❑
_Door
24
_0..3.8.7_
45_
9.0_
LX
❑
Wall-
30_
_0...0_4.5_
_9.0.
9.0_
LX
❑
Wall_
84
0.045
1.35
90
LXI
❑
Wall-
30
0.0_4.5
1.8.0.
90
[XI
❑
Wall-
62_
004.5
_225
90
A
❑
-Door2.4_
0.387
_225.
90
LX
❑
Form 3 Reference
_Rd_9_Wall_wL1"EP_S
_R_3.8_Roof_(R. $8.2x4.2.4.)
.R_1.9_Wall_wtl"" EP-S-
-13=19-Wall-w]-l"
P_S
_R_1.9_W_ all_wl_1"EP_S
.R_1.9_WaILw/1"ERS-
R=19-Wall-WILE S
P_S.R_1.9_Wallw/_1°EP_S
.R_1.9_WaII wL1_E.P_S
R_38_Roof_(R.38.2x4.24)
.R_19_W a I I_w/_1"E P_S
_R_19_Wall_w/_1° EP_S
-Solid-Wood-Door
.R-7-1-9-Wall-w./-1-"EP-S-
R-19
R_1.9_Wall w/_1_EP_S
R=19 Wall w/1" EPS
.R=1 -9 -Wall -w/-1" EP_S
.R_1.9_Wall_w/_1"EP_S
. R _1.9_W a l l _w/_1"E P_S
.R_1.9_W al l-w/_1_EPS
_R_1.9_W a I I _w/_1_E P_S
.13_1.9_Wa ILw/_ " EP_S
. R _1.9_W a l l _w /_1"E P_S
Solid -Wood -Door
.R_1.9_W a l I _w/_1_E P_S
_R_1.9_W a II_w/_1_EP_S
_S.olid_Wood_Doo.r
.5L1.9 -Wall -w/ -1-"E S
R_19_W_ __all_M-1_EP_S
.R_1.9_W a I I_w/_1"E P_S
_Rd9_Wall w/_1"EP_S
-S-olid-Wood-Dow
Location / Comments
.Zn_I_M str. Bd rm.,_2_Bd rm s
.Zn_I I_Hal I, Lvng,.G rtRm
.Zn_ll_Hal I, Lvng,GrtRm
.Zn_I I_Hall, Lvng,G rtRm
.Zn_LI_Hal I, Lvng,GrtRm
.Zn_ll_Hall, Lvng,.GrtRm
.Zn_LI_Hal I, Lvng,GrtRm
.Zn -I LI_Bdrms,Dnng,Nk
.Zn_LLI_Bd rms, D.n n g, N k
.Zn_LLI_Bd rms,Dn ng, Nk
.Z n_LLI_Bd rm s, D.n n g , N k
.Z n_l l l_Bd rm S, D.n ng,N k
.Z n_ll l_Bd rm s, D n ng, N k
.Zn_I LI_Bd rms, D.n n g, N k
Z n_ll l_Bd rms, D.n n g, N k
.Z n_I Il_Bd rms, D n n g, N k
.Zn_lll-Bd rms, D.n ng, N k
.Zn_I Il_Bdrms,D.n ng,N k
.Z n_ll I_Bd rm s, D.n n g, N k
.Zn_l l l_Bd rm s., D.n ng, N k
Zn_II.I_B.drms.,Dnng,Nk
.Zn_I I I_Bd rms, Dn n g, N k
.Zn_I I I_Bdrms, Dnng,N k
.Zn_ll I_Bd rms,D.nng, N k
.Zn_ILI_Bd rms,D.nng, Nk
.Z n_LLI_Bd rm s, D n n g, N k
.Z n_ll I_Bd rm s, D.n n.g, N k
.Z n_ll I_Bd rm s, D n ng, N k
.Zn_LLI_Bd rm s,D.n n g,N k
I EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Paae:10 of 17 1
Computer Method Summary (Part 2 of 3) C -2R
CHRIS HARRIS 1/27/2005
Project Title Date
FENESTRATION SURFACES
# Type
Area
U-
Factor
SHGC
Act.
Azm.
Glazing Type
Tilt
Location/
Comments
1_
Window -Left -
(Northeast)
42.0_
_0.._420_
_0.32.
45_
_9.0. FLEET-_ _OQD ALUMINUM
-Zn_I_Mstr.B_drm,2Bdrms_
2
Window Front(Northwest)
42.0
0.420
0.32
315
90 FLEETWOOD ALUMINUM
_ Zn I Mstr.Bdrm, 2 Bdrms
3
Window Front
Northwest)
3.2
0.400
0.39
315
90 FLEETWOOD ALUMINUM
Zn I Mstr.Bdrm, 2 Bdrms
4
Window Right
Southwest)
9.0
0.420
0.32
225
90 FLEETWOOD ALUMINUM
Zn I Mstr.Bdrm, 2 Bdrms
5
Window Right
Southwest)
25_0
0.420
0.32
225
90 FLEETWOOD ALUMINUM
Zn I Mstr.Bdrm, 2 Bdrms
6
Window Right
(Southwest)
16.0
0.420
0.32
225
90 FLEETWOOD ALUMINUM
Zn I Mstr.Bdrm, 2 Bdrms
7
Window Right
(Southwest)
16_0
0.420
--Q-a2
225
90 FLEETWOOD ALUMINUM
Zn I Mstr.Bdrm 2 Bdrms
8
Window RightSouthwest)
10.0
0.440
0.29
225
90 FLEETWOOD ALUMINUM
Zn I Mstr.Bdrm, 2 Bdrms
9
Window Right_(Southwest)
100
0.400
0_39
-225
90 FLEETWOOD ALUMINUM
Zn I Mstr.Bdrm, 2 Bdrms_
10
Window Right -(Southwest)
9_0
0.4000
39
225
90 FLEETWOOD ALUMINUM
Zn I Mstr.Bdrm 2 Bdrms
11
Window Right
(Southwest)
15.0
0.500
0.30
225
90 FLEETWOOD ALUMINUM
Zn I Mstr.Bdrm. 2 Bdrms
12
Window Right
(Southwest)
_ 15.0
0.500
0.30
225
90 FLEETWOOD ALUMINUM
Zn I Mstr.Bdrm, 2 Bdrms
13
Window Rear_(.South)
_2.4.0_
0.400-
0.39
1.80_
_90 FLEE_TW__QQD_ALUM.I.NUM
_Zn_I_Mstr,Bd.rm.,_2_Sd.rms_
14
Window Rear
(Southeast)
60.0
0.450
0.35
135
90 FLEETWOOD ALUMINUM
Zn I Mstr.Bdrm, 2 Bdrms
15
Window Left
East _
24.0
0.400
0.39
90
90 FLEETWOOD ALUMINUM
Zn I Mstr.Bdrm, 2 Bdrms
16
Window Rear
(Southeast)
2.2
0.400
0.39
135
90 FLEETWOOD ALUMINUM
Zn I Mstr.Bdrm, 2 Bdrms
17
Window Rear
(Southeast)
2.2
0.400
0.39
135
90 FLEETWOOD ALUMINUM
Zn I Mstr.Bdrm, 2 Bdrms
18
Window Rear
Southeast)
2.2
0.400
0.39
135
90 FLEETWOOD ALUMINUM
Zn I Mstr.Bdrm, 2 Bdrms
19
Window Right_(.Southwest)
80_0
0.450
---Q.35
225
90 FLEETWOOD ALUMINUM
Zn II HallLvng GrtRm
20
Window Rear
(Southeast)
12800
0.450
0.35
135
90 FLEETWOOD ALUMINUM
Zn II Hall,Lvng,GrtRm
21
Window Front
(Northwest)
28.0
0.440
0.29
315
90 FLEETWOOD ALUMINUM
Zn II HaII,Lvng,GrtRm
.22.
Window Front
(Northwest)
96.0
0.450
0.35
315
90 FLEETWOOD ALUMINUM
Zn II Hall .Lvng,GrtRm
23
Window Right (Southwest)
_4.0_0
0.440
0.29
225
90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng,Nk
24
Window Front
(Northwest)
2.2
0.440
0.29
315
90 FLEETWOOD ALUMINUM
Zn III Bdrms Dnng,Nk
25
Window Front
Northwest)
2.2
0.440
0.29
315
90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng,Nk
26
Window Left
(Northeast)
2.2
0.400
0.39
45
90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng,Nk
27
Window Left
(Northeast)
2.2
0.400
0.39
45
90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng,Nk
28
Window Left
(Northeast)
2.2
0.400
0.39
45
90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng,Nk
29
Window Rear
(Southeast)
20.0
0.400
0.39
135
90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng,Nk
INTERIOR AND EXTERIOR SHADING
Window
Overhang
Left Fin
Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len. Hgt. LExt. RExt. Dist. Len.
Hgt. Dist. Len. Hgt.
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
_
6
Bug Screen
0.76
_
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
B�cu Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
8.0
3.0
_
6.0
0.1 6.0 6.0
14
Bug Screen
0.76
10.0
6.0_
6.0
0.1 6.0 6.0
15
Bug Screen
0.76
8.0
3.0
6.0
0.1 6.0 6.0
16
Bug Screen
0.76
1.5
1.5
15.5
0.1 2.0 2.0
17
Bug Screen
0.76
1.5
1.5
15.5
0.1 2.0 2.0
18
Bug Screen
0.76
1.5
1.5
15.5
0.1 2.0 2.0
19
Bug Screen
0.76
8.0
8.0
15.0
0.1 2.0 2.0
20
Bug Screen
0.76
10.0
16.0
13.0
0.1 2.0 2.0
21
Bug Screen
0.76
8.0
3.5
11.0
0.1 2.0 2.0
22
Bug Screen
0.76
8.0
12.0
4.5
0.1 4.0 4.0
23
Bug Screen
_ 0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
_
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
1.6
1.6
__
2.5
0.1 2.0 2.0
_
I EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page:11 of 17 I
Computer Method Summary (Part 2 of 3) C -2R
CHRIS HARRIS 1/27/2005
Project Title Date
FENESTRATION SURFACES
U_ Act. Glazing Type Location/
# Type Area Factor SHGC Azm. Tilt Comments
_3.0.
31
Window -Left -(Northeast)
Window Rear
(Southeast)
32
Window
Rear
(Southeast)
33
Window
Left
Northeast)
34
Window
Left
(Northeast)
35
Window
Left
(Northeast)
36
Window
Left_(Northeast)
37
Window
Rear
(Southeast)
38
Window
Rear
(Southeast)
39
Window
Rear
(Southeast)
40
Window
Left
(East)_
41
Window
Rear
(Southeast)
_4.2
43
Window Rear_(.South.)
Window Right (Southwest)
0.39
135
90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng,Nk
_2.2 2
0.400
0 39
135
90 FLEETWOOD ALUMINUM
Zn III Bdrms Dnng,Nk
2.2
0.400
__k39
135
_ 90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng,Nk
17_5
0.400
0.39
90
90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng,Nk
42.0
0.400
0.39
135
_ 90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng. Nk
-J-7..5-
0._400_
___0.39
1.80_
_90 FLEETW00D ALUM.I.N M
Zn_I.I.I_Bdrms.,Dn. ng,Nk
24_1
_ 0.400
0.39
_ 225
90 FLEETWOOD ALUMINUM
Zn III Bdrms.Dnng,Nk
1.6.0_
_0.420_
-.-0.32.
4.5_
_9.0. FLEE.T_W_ _OOD ALUMINUM
_Zn_I.II_B.drms,Dnng,Nk
_16.0
0.420
_ 0.32
135_
90 FLEETWOOD ALUMINUM
Zn III Bdrms.Dnng,Nk
48.0
0.450
0.35
135
90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng,Nk
8.0
0.400
0.39
45
90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng,Nk
_ 2_2
0.400
_ 0.39
45
90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng,Nk
2.2
0.400
0.39
45
90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng,Nk
_2.2
0.400_
0 39
4590
FLEETWOOD ALUMINUM
Zn III Bdrms,Dnna,Nk
16.0
0.400
0.39
135
90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng,Nk
_2.2 2
0.400
0 39
135
90 FLEETWOOD ALUMINUM
Zn III Bdrms Dnng,Nk
2.2
0.400
__k39
135
_ 90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng,Nk
17_5
0.400
0.39
90
90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng,Nk
42.0
0.400
0.39
135
_ 90 FLEETWOOD ALUMINUM
Zn III Bdrms,Dnng. Nk
-J-7..5-
0._400_
___0.39
1.80_
_90 FLEETW00D ALUM.I.N M
Zn_I.I.I_Bdrms.,Dn. ng,Nk
24_1
_ 0.400
0.39
_ 225
90 FLEETWOOD ALUMINUM
Zn III Bdrms.Dnng,Nk
INTERIOR AND EXTERIOR SHADING
# Exterior Shade Type SHGC
30
Bug Screen
0.76
31
Bug Screen
0.76
32
Bug Screen
0.76
33
Bug Screen
0.76
34
Bug Screen
0.76
35
Bug Screen
_ 0.76
36
Bug Screen
0.76
37
Bu Screen
n 7a
38
39
40
41
42
43
9
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
0.76
Left Fin Right Fin
0.76
0.76
7.0
2.5
4.5
0.1
4.0
4.0
0.76
7.0
6.0
_
4.5
Overhang
Window
4.0
Hgt. Wd.
Len.
Hgt. LEA
REA Dist. Len. Hgt. Dist. Len. Hgt.
8.0 _ 6.0
4.0
0.1 4.0
4.0
8.0 8.0
19.0
0.1 0.0
0.0
8.0 2.5
19.0
0.1 0.0
0.0
8.0 1.5
15.2
0.1 2.0
2.0
8_0 8 0
_j_5_2
0 1 _ 2_0
2.0
8.0 4.4
8.0
0.1 8.0
8.0
0.76
0.76
0.76
7.0
2.5
4.5
0.1
4.0
4.0
0.76
7.0
6.0
_
4.5
0.1
4.0
4.0
0.76
7.0
_ 2.5
4.5
0.1
4.0
4.0
0.76
9.7
2.5
4.5
0.1
4.0
_
4.0
3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Pape: 12 of 17
Computer Method Summary
Minimum
(Part 3 of 3) C -2R
Insulation
Type
CHRIS HARRIS
Factor
R -Val. Depth
1/27/2005
Project Title
226
0.760
Date
THERMAL MASS FOR HIGH MASS DESIGN
Slab_P_erimeter
76
0.7.6
Area Thick. Heat
ZoJ.I_Hall,Lvng.,GrtR-m
Inside
Location
Type (sf) (in.) Cap.
Cond. Form 3 Reference
R -Val.
Comments
Concrete, Heavyweight _2,49.9. _3..5.0 _28.
_0..98. n/a
_2.
Zn_I_Mstr..B.drm,2_B.drms_/_S.lab_onGrade
Concrete. Heavyweight 1,679 3`50 28
0_98 n/a
0
Zn II Hall.Lvng,GrtRm / Slab on Grade
Concrete, Heavyweight 1,700 3 50 28
0_9a n/a
0
Zn III Bdrms,Dnna Nk / Slab on Grade
Concrete. Heavyweight 555 3_50 28
0_98 n/a
2
Zn III Bdrms Dnng,Nk / Slab on Grade
WATER HEATING SYSTEMS
PERIMETER LOSSES
HVAC SYSTEMS
Heating Equipment
Minimum
F2
Insulation
Type
Length
Factor
R -Val. Depth
Location / Comments
81ab Perimeter
226
0.760
0 0
Zn I Mstr_Bdrm 2 Bdrms
Slab_P_erimeter
76
0.7.6
0...0. 0
ZoJ.I_Hall,Lvng.,GrtR-m
Slab Perimeter
175
--Q-.7-6
20 0
Zn III Bdrms Dnng,Nk
Slab_Pedrneter
—28.
_01-6.
0.0 —0
Zn_I.I.I_Bdrms.,Dn.ng,Nk
HVAC SYSTEMS
Heating Equipment
Minimum
Distribution Type
Type (furnace, heat
Efficiency
and Location
Duct
Thermostat
Location /
pump, etc.)
(AFUE/HSPF)(ducts/attic,
etc.)
R -Value
Type
Comments
Central Furnace
8U AFUE
DuctsinAttic
4.2
Setback
HVAC Syst. Zone I
Central Furnace
80% AFUE
Ducts in Attic
4.2
Setback
HVAC Syst. Zone II
Central Furnace
80% AFUE
Ducts in Attic
4.2
Setback
HVAC Syst. Zone III
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Cooling Equipment
Minimum
Duct
Type (air conditioner,
Efficiency
Location
Duct Thermostat
Location /
heat pump, evap. cooling)
(SEER)
(attic, etc)
R -Value Type
Comments
Split Air Conditioner
12.0 SEER
DuctsinAttic
4.2
Setback
HVAC Sy_st. Zone I
Split Air Conditioner
12.2 SEER
Ducts in Attic
4.2
Setback
HVAC Syst. Zone II
Split Air Conditioner
12.0 SEER
Ducts in Attic
4.2
Setback
HVAC Syst. Zone III
WATER HEATING SYSTEMS
Ratedl
Tank
Energy Facts 1 Tank Insul.
Water Heater
Water Heater Distribution
# in Input
Cap.
or Recovery Standby R -Value
System Name
Type
TypeSyst.
(Btu/hr)
(gal)
Efficiency Loss (%) Ext.
A.O.Smith FSG -75-230
Small Gas
Standard
2 75 000
74
0.4a n/a 12
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMAR
Computer Method Summary (Addendum) C -2R
CHRIS HARRIS 1/27/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. Plan Field
The DHW System "A.O.Smith FSG -75-230" Energy Factor = 0.480. An EF below 0.58 requires an R-12 External Blanket.
The HVAC System "HVAC Syst. Zone I " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 2499 sqft Covered Slab Floor, 3.50" thick at Zn I Mstr. Bdrms, Bdrms 4&5
The HVAC System "HVAC Syst. Zone II " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1679 sqft Exposed Slab Floor, 3.50" thick at Zn II Hall, Lvng,GreatRm
The HVAC System "HVAC Syst. Zone III " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1700 sqft Exposed Slab Floor, 3.50" thick at Zn III Bdrms,Dnng,Nook
HIGH MASS Design(see C -21R) - Verify Thermal Mass: 555 sqft Covered Slab Floor, 3.50" thick at Zn III Bdrms,Dnng,Nook
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
v..... . . n- ..uw 1-1 nwm .—M ... —11 L.— ..— YG11 nLia LIV11 011V u14911VaL16 LCSuny VI 11105C f11b'ab UnIb on a Torm I Plan I Field
Run Initiation Time: 01/27/05 16:50:54 Run Code: 1106873454
EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page: 14 of 17
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME
CHRIS HARRIS
DATE
1/27/2005
SYSTEM NAME
HVAC Syst. Zone 1
FLOOR AREA
2,499
ENGINEERING CHECKS
Number of Systems 1;
ISYSTEM LOAD
COIL COOLING PEAK COIL HTG. PEAK
;CFM !Sensible Latent CFM Sensible
Total Room Loads 1,132 21,972 1,162 760 23,802
Return Vented Lighting 0
Return Air Ducts 1,099 1,190
Return Fan 01 0
Ventilation 01 0 0 0 0
Supply Fan 0 0
Supply Air Ducts 1,099 1,190
TOTAL SYSTEM LOAD 1 24,16911,162, 26,183
Heating System
Output per System 65,000,1
Total Output (Btuh) _ 65,00001
Output (Btuh/sgft) 26.0
Cooling System
Output per System 58,500
Total Output (Btuh)
58,500
Total Output (Tons)
I 4.9
Total Output (Btuh/sqft)
23.4
_I
Total Output (sgft/Ton)
512,7
Air System
HVAC EQUIPMENT SELECTION
CFM per System
2,000
York H4DH060/PDHUCO20L60 U&H 41,025 12,664 65,000
Total Adjusted System Output 41,025 12,664 65,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
Airflow (cfm)
2,000
Airflow (cfmisqft)
0.80
Airflow (cfmlTon)
410.3
Outside Air (%)
0.0
Outside Air (cfm/sqft)
_
0.00
_
Note: values above given at ARI conditions
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0 of 69.4 of 69.4 of 100.0 °F
O 4S Supply Air Ducts
Outside Air
0 cfm 99 4 of
Supply Fan Heating Coil
2000 cfm ROOMS
69.4 of 70.0 of
Return Air Ducts I
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0/77.6OF 80.5/66.7OF 80.5/66.7°F 61.2/60.1OF
O Supply Air Ducts
Outside Air
0 cfm Supply Fan Cooling Coil 61.8 / 60.3 of
2000 cfm 49.7% R.H. ROOMS
80.5 / 66.7 °F 80.0 / 66.5 of
Return Air Ducts I
EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page. 15 of 17
1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
CHRIS HARRIS 1/27/2005
SYSTEM NAME FLOOR AREA
HVAC Syst. Zone II 1,679
Number of Systems
1
Heating System
Output per System 64,000
Total Output (Btuh) 64,000
Output (Btuh/sgft) 38.1
Cooling System
Output per System
48,000
Total Output (Btuh)
48,000
Total Output (Tons)
4.0
Total Output (Btuh/sqft)
28.6
Total Output (sgfUTon)
419.8
Air System
CFM per System
1,600
Airflow (cfm)
1,600
Airflow (cfm/sgft)
0.95
Airflow (cfm/Ton)
400.0
Outside Air (%)
0.01
Outside Air (cfm/sgft)
0.00)
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK 1
COIL HTG. PEAK
CFM Sensible
Latent
CFM
Sensible
633
15,241781
337
13,190
0
762
660
0
0
0
0
0
0
0
0
0
762
660
16,765 781
York H4DH048/P4HUB16L064 U&H 40,077 2,182
Total Adjusted System Output 40,077 2,182
i (Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK I Aug 2 pm
14,509
64,000
64,000
Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0 of 69.6 of 69.6 of 107.2 of
O Supply Air Ducts
Outside Air
0 cfm 106.8 of
Supply Fan Heating Coil
1600 cfm ROOMS]
70.0 of
69.6 of
k Return Air Ducts 4
(COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak)
111.0 / 77.6 OF 80.4 / 64.10 80.4 / 64.1oF . 56.9 / 55.6 of
Outside Air
0 cfm
80.4/64.10F
Supply Fan Cooling Coil
1600 cfm
Return Air Ducts
Supply Alr Ducts
57.4 / 55.7 of
41.7% R.H. ROOMS
80.0 / 64.0 of
EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page: 16 of 17�
1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
CHRIS HARRIS 1/27/2005
SYSTEM NAME FLOOR AREA
HVAC Syst. Zone III 2,255
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAKCOIL
HTG. PEAK
CFM
Sensible
Latent
CFM
Sensible
21,066 1,048
York H4DH060/PDHUCO20L60 U&H 41,052 12,564
Total Adjusted System Output I 41,0521 12,564
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK I Aug 2 pm
HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatina Peakl
26.0 OF 69.5 OF 69.5 OF ® 100.0 °F
Outside Air
0 cfm
69.5 OF
102
Supply Fan Heating Coil
2000 cfm
�% Return Air Ducts 4
24,894
65,000
65,000
Jan 12 ann
Supply Air Ducts
99.5 OF
ROOMS
70.0 OF
(COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) I
111.0/77.6°F 80.4/66.6°F 80.4/66.6°F . 61.2/60.0°F
r1
Outside Air
0 cfm
80.4/66.6 °F
Supply Fan Cooling Coil
2000 cfm
Return Air Ducts
Supply Air Ducts
61.6 / 60.2 of
49.5% R.H. ROOMS
80.0 / 66.4 OF
EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY91-1004 Page: 17 of 17
78-495 CALLE TAMPICO
haw
LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number: BRES2017-0181
Property Address: 53395 VIA STRADA
APN: 777200001
Application Description: GLADNEY / ADD BATHROOM AT EXISTING OFFICE
Property Zoning:
Application Valuation: $25,000.00
Applicant: D
ANTON MARINKOVICH
550 S OLEANDER RD AUG 0 8 2011 DD
PALM SPRINGS, CA 92264
CITY CP LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
(commencing with Section 7000) of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: B. C54 License No.: 655 [ �
Date: `� " � ' (� Cdntr�
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects' the applicant to a civil penalty of not more than five hundred dollars ($500).:
( 11, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or she did not build or improve for the purpose of sale.).
I 11, as owner of the property, am exclusively contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractor(s) licensed pursuant to the
Contractors' State License Law.).
(_J I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Na
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 8/8/2017
Owner:
DAN AND DIANE GLADNEY
53395 VIA STRADA
LA QUINTA, CA 92253
Contractor:
GALATI ENTERPRISES INC
78050 CALLE CADIZ
LA QUINTA, CA 92253
(760)777-9994
Llc. No.: 655861
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
ofwork for which this permit is issued.
1 1 have and will maintain workers' compensation insurance, as required by
Secti 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier: BENCHMARK INSURANCE COMPANY Policy Number: CST5009259
_ I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
l)ate:.o�
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above-
mentioned property for inspection purposes. �/�I1N11r�.W11���Af1,,�1
Raro•� �� � ` 1 �ao��r��ro le.,.,�ir•�r,r �r eao.,r1•Wt t�'�/ lI
Date: 8/8/2017
Application Number: BRES2017-0181 Owner:
Property Address: 53395 VIA STRADA DAN AND DIANE GLADNEY
APN: 777200001 53395 VIA STRADA
Application Description: GLADNEY / ADD BATHROOM AT EXISTING OFFICE LA QUINTA, CA 92253
Property Zoning:
Application Valuation: $25,000.00
Applicant:
Contractor: ,
ANTON MARINKOVICH
GALATI ENTERPRISES INC
550 S OLEANDER RD
78050 CALLE CADIZ
PALM SPRINGS, CA 92264
LA QUINTA, CA 92253
(760)777-9994
------7-------------------------------------------------------------------------------------
Llc. No.: 655861
Detail: GLADNEY / ADD BATHROOM TO EXISTING OFFICE RESULTING IN AN ADDITION OF 17 S.F OF CONDITIONED SPACE. SITE SPECIFIC ENGINEERING
(B.G. STRUCTURAL ENGINEERING). WORK FULLY COMPLETED PRIOR TO PERMIT
ISSUANCE --CONTRACTOR TO EXPOSE CONSTRUCTION FOR INSPECTION
AS NECESSARY. 2016 CALIFORNIA BUILDING CODES.
ar-
INFORMATION
DESCRIPTION ACCOUNT
QTY
AMOUNT
ADDITION, FIRST 100 SF
101-0000-42400
0
$127.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$179.36
• Total Paid for ADDITION: $307.04
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$1.00
Total Paid for BUILDING. STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DEVICES, FIRST 20
101-0000-42403
0
$25.33
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DEVICES, FIRST 20 PC
101-0000-42600
0
$25.33
Total Paid for ELECTRICAL: $50.66
DESCRIPTION
ACCOUNT
QTY
AMOUNT
VENT FAN
101-0000-42402
0
$12.67
DESCRIPTION
ACCOUNT
QTY
AMOUNT
VENT FAN PC
101-0000-42600
0
$5.07
Total Paid for MECHANICAL: $17.74
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$38.01
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$38.01
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$12.67
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$12.67:77J
Total Paid for PLUMBING FEES: $101.36
DESCRIPTION
ACCOUNT
QTY
AMOUNT
REMODEL, FIRST 100 SF
101-0000-42400
0
$51.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT
REMODEL, FIRST 500 SF PC
101-0000-42600
0
$141.36
Total Paid for REMODEL: $193.04
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$3.25
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $3.25
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
TOTALS:••
Bin #
City of La Quinta
-Building 8L Safety Division
78-495 Calle Tampico.
La Quinta, CA 92253- (760) 777-7012
d' &8/ Building Permit A lication and Tracking
pP g Sheet ,
Permit #
,,%NA—
Project Address: 5-53,7.5—
Owner's Name: h ��
A. P- Number: 1 . )
Address: Jf -3�;T--• U/4
Legal Description:
City, ST, Zip:
Contractor:
TelePhone: 7v• ��/ / Z
`'?'`'•`v'`
Address: 7S-Zj cgez_ C.A7Z
Project Description:S
�J /LT
City, ST, Zip:, U/
ele hn-
Telephone: 777, 2YE11
_
d s^N. �S7ytib .
7
State
State Lic. # :
City Lic. M
Arch., Engr., Designer.
Address: 7S-/%s—
City, ST, Zip:. Plie-/t'1 /�
Telephone• ::.. ;:.:.;:.::•<;r
•7�li7�,�p�j• $�— -� •-f:->:»-:.>:.>�•:?�:
"
'...
>30 ....State Lic. #: :.
Name of Contact Person: N 1-J1%A1Nl;Ujf14j
Construction Type: Occupancy:
Project type (circle one): New dd'n Alter Repair Demo
Sq. Ft.:
# Stories:
# Units:
Telephone # of Contact Person:(oO . S67-,39K--/
Estimated Value of Project: $— 000
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Rec'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item Amount
Structural Cales.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2" Review, ready for correctionsfissue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A: Approval
Plans resubmitted
Grading
IN HOUSE:
'"' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
lg:n
u �
Total Permit ees
JUL. 2 5 2017
CITY OF L4 ®UINTA
COMMUNITY DEVELOPMENT
4
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) �VCETVEU 98-1224
AUG 0 8 2017
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
I COMM/IND. AMOUNT:
DATE:
RECEIPT:
CHECK #:
INITIALS
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: jThe Hidea
Owner's Name: Dan and Diane Gladney
Project Address: 53-395 Via Estrada
Project Description: Addition to Existing Dwelling
APN: 777200001 Tract #:
Date: August 4, 2017
Phone No. 760-777-9994
Lot #'s:
Type of Development: Residential XX! Commercial Industrial
Total Square Feet of Building Area: 17 sq. ft.
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized �o sign opb.ehalf of the owner/developer.
Dated: August 4, 2017 Signature: \J
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Project Agreement Existing Not Subject to Fee
17620 65995 Approval Prior to 1/1/87 Requirement
Note:
Number of Sq.Ft. 17 Pursuant to AB 181 any room additions or enclosures of 500
Amount per Sq.Ft. $0.00 sq. ft. or less are exempt from developer fees. Any mobile
homes being relocated within the same school district's
Amount Collected $0.00 jurisdiction are exempt from developer fees.
Building Permit Application Completed: Yes/No
By: Elsa F. Esqueda, Director of Facilities and Maintenance
Certificate issued by: Laurie Howard, Secretary Signature: ac {w&A d
v -
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
MV:chn�docti'devtces/certiticate of compliance Form updated 3-2007 11/2010