Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
12-0694 (SFD)
_ y/ 4 P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number:_12-00000694 Owner: `Property Address: 53351 VIA STRADA JOSEPH & JENNIFER CVETAS APN: 772-520-052- - - C/O THE CVETAS FAMILY TRUST Application description: DWELLING - SINGLE FAMILY DETACHED 9351 GATXSHEAD RIVE Property Zoning: LOW DENSITY RESIDENTIAL HUNTINGTON BEACH, CA 926 ,6_ Application valuation: 541478 D Contractor: �Cwftr� VOICE (76 0) 77-7 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/27/12 a 01 -at, 2a2 Applicant: Architect or Engineer: FEDDERLY & ASSOCIATES �j 38747 NOPALES ROAD l�C PALM DESERT, CA 92211 -.C, -Vv- OF LAQU1 J. I� (760)773-5205 FIhEAq`?CC CE��T� Lic. No.: 762889 --�-� -------------------------------------------------------------------------------------------- --- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. icense Class: 13 License No.: 762889 V Date: �ntractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EVEREST INS Policy Number 760000440081 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section �n 3700 oof a Labor Co(dee,,�I shall forthwith co/m�plyywitch those provisions. Date: W 4 �Z Applicant: �/ V L(�[.Orti� ( ./V11�mmlt-/ WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 1$100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this count to�e,nI upon the above-mentioned property for inspection purposes. 000, Date: 16 .1 1 Signature (Applicant or Agent): .r / "Amet� Application Number . . . . . 12-00000694 Permit . . . . . . MECHANICAL LQPERMIT Structure Information Construction Type . . . . . TYPE V, UNPROTECTED Occupancy Type . . . . . DWELLG/LODGING/LONG <=10 Other struct info . . . . . CODE EDITION 2010 # BEDROOMS 4.00 FIRE SPRINKLERS YES GARAGE SQ FTG 929.00 PATIO SQ FTG 1316.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 4349.00 ---------------------------------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE 972.00 Permit . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 2165.50 Plan Check Fee 1407.58 Issue Date . . . . Valuation . . . . 541478 Expiration Date . . 3/26/13 Qty Unit Charge Per Extension BASE FEE 2039.50 42.00 3.0000 ---------------------------------------------------------------------------- THOU BLDG 500,001-1,000,000 126.00 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . . Permit Fee 261.14 Plan Check Fee 65.29 Issue Date . . . . Valuation . . . . 0 Expiration•Date . . 3/26/13 Qty Unit Charge Per Extension BASE FEE 15.00 5321.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 186.24 2245.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 44.90 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit . �. . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/26/13 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . . . . MECHANICAL LQPERMIT Application Number . . . . . 12-00000694 Permit . . . MECHANICAL Additional desc . . Permit Fee . . . . 185.00 Plan Check Fee 46.25 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/26/13 Qty Unit Charge Per • Extension BASE FEE 15.00 3.00 9.0000 EA MECH FURNACE <=100K 27.00 2.00 11.0000 EA MECH FURNACE >100K 22.00 4.00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 2.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 33.00 7.00 6.5000 EA MECH VENT FAN 45.50 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 225.75 Plan Check Fee 56.44 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/26/13 Qty Unit Charge Per Extension BASE FEE 15.00 23.00 6.0000 EA PLB FIXTURE 138.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 6.0000 EA PLB ROOF DRAIN 6.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 13.00 .7500 EA PLB GAS PIPE >=5 9.75 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 2 STORY SFD. 5321 SF LIVING, 807 GARAGE W/ HVAC, 1316 SF COVERED PATIO. 2010 CODES W/ FIRE SPRINKLER. **PERMIT DOES NOT INCLUDE BLOCK WALLS, FENCES, SWIMMING POOLS, SPA, FIRE PITS, BBQ'S & DRIVEWAY APPROACH** ENGINEER: REZA ASGHARPOUR C67613. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 853.70 BLDG STDS ADMIN (SB1473) 19.00 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 140.76 DIF FIRE PROTECTION -RES 140.00 LQPERMIT Application Number . . . . . 12-00000694 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . DIF LIBRARIES - RES 355.00 MULTI -SPECIES (MSHCP) FEE 1254.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 54.15 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid Credited Due ----------------- Permit Fee Total ---------- 2852.39 ------------------------------ .00 .00 2852.39 Plan Check Total 1575.56 1000.00 .00 575.56 Other Fee Total 6796.61 .00 .00 6796.61 Grand Total 11224.56 1000.00 .00 10224.56 LQPERMIT Building Address 5335 vin /� tmda :..] `� '1W (GV Mailing —t t ! Address 12�/ It 1 f v� i 11 ! v� ��/1 �T • t� P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING: TYPE CONST— A.P.Number Legal Description APPLICATION ONLY OCC. GRP. Address -141oaam Citoalmty��Zipq 22(1 Tel. 1W- 11 -5205 State Lic. ,n p City Sq. Ft. % NO. �f No. Dw. & Classif. -7 U2-281 Lic. # �/ a� Size lY Stories (,,. Units Arch., Engr., P7PA ?,/hj 9 �4ctyj�� New Add ❑ Alter ❑ Repair ❑ Demolition ❑ Designer ner /f CiN �� � Zip���� State ���91 Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby m that I a icensed under provisions of Chapter 9 (commencing w'th Section 7000) f Sion 3 of Professions Code, and my license is i0 f ,f ;qand effect (D SI ATU DATE OWNER -BUILDER DECLARATION I hereby affirm t t I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencinwith Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt thg erefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sej. 3800, La or ode.) Policy No 1b01900044©IlQimpany x Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE 7 Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure �. 1 _iu r ( t TOTAL REMARKS, ^r ' `-A_ IaCUiN7k ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE 7 Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 Project Name: Owner's Name: Joe and Jennifer Cvetas Project Address: 53-351 Via Strada, La This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVELTWOAMOUNT: MITIGATION AMOUNT: I COMMAND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) CA 92253 Project Description: New Single Family Dwelling APN: 777 180014__-- Tract M , Type of Development: Residential XX Commercial Total Square Feet of Building Area: 5321 Date: September 26, 2012 Phone No. (760) 773-5205 Lot #'s: Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: Signature: ********************************************************************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code Project Agreement Existing Not Subject to Fee 65995 Approval Prior to 1/1/87 Requirement 6128 $3.20 $19609.60 Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Note:; Certificate issued by: Marcela Valdez, Construction Analyst Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a wkcesof tice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest then of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Nll serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or perfor any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up . to three (3) such extensions may be granted. `ut1' Iat<is :,,.i;:t .rs. cr?.i1i;,Itu :=t f:€n;+ irr::r tE rr€I €ptl,:ie=.i 3-20()". 11/2010 CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 912512009 Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot beprocessed will be returned to applicant. Date: 0 /Z�/ I'I--�Developer: (,IjjcV6 Tract No.: 29 V -l'ZTract Name: c (�' Lot N Address(s): J5 Via S 1 Y adA P The following are the requirements for Public Works Clearance to Building & Safety Department: 4. 2. 3. 4. 5. 6. 7. TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW S/OTHER• PROVIDE ITEMS #1 s): ��� )rig issuance o -"a bui ding permit from the UL 13 2012 MWAM A� ELIC wontJUN 28/201/2 .S COMMERCIAL BUILDING - - - - ICW0 WALLS SIGNS OTHER: PROVIDE ITEM #6 BELOWRKS +flevelopmentServiCes Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation Certificate can be provided. Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils Engineer. Recently rough graded residential developments which have a previously approved geotechnical certification are exempt from this requirement. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots. Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 certification number is required. Attach a copy of the rough or precise grading plan to the Public Works Department showing building location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain development plan. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW approved building construction projects require either a WQMP or a completed WQMP exemption form. Approved maps/plans may be viewed at the following link: httr)://www.la-guinta.org/PlanCheck/m search.aspx I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff. p Recommended by: Date: Public Works Distribution: ( ) Green Sheet to Building & Safety ( ) Green Sheet to Planning Department Declined for approval for reason(s) as follow(s), please'correct and resubmit: ro • v T:\Checklists - Forms & Applicalions\Forrns & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc City of La Quinta - PM10 Fugitive Dust Control Project Information Construction Phase PM10 Agreement <1 acre/lot or Infill Project Proiect Information Project Contractor: �G�G�I �- (i�a,��� Project Phase (check one) Construction Demolition Total Acres in Active Construction (<1 acre per Lot): . 50 At -rzG Project Name: CM -t -as Project Tract/Lot Numbers: Z- 1 � � Z / 2-4 " Project Street Address: � V �a Sh-A01 q L4 Vita 1 ZZ�3 Anticipated Start Date: / / Anticipated Completion Date: PM10 Contact Please note: Dust control is required 24 hours a day, 7 days a week, regardless of Information construction status. Person listed below is responsible for dust control during business and non -business hours. Name: I --U f % I Title: V E Com an Name: to 4 Lm Mailing Address: "f l8(p5 �)Oa, cA UAA k J� , State, ZIP Code: PAA V" L, -6f `, 1 C4A ri 7-2-1 Primary Phone #: I WO - 1510.- 4DOCS Fax #: (p0 - 540 Z7JM . 24 Hour Emergency 00 , Phone#: Cell Phone M (PO - 518- 400 Email Address: Y -Y- LA+ -f PM10 Certificate M I CV ti J C)L4 The above stated property owner (or authorized representative): ❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; ❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; ❖ Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes; ❖ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control plan or any City/Counj*initiated abatement activities. or T:\Checklists - F pplications\Forms & Applications\GREEN SHEET cove& PM10less than 1 Acre Revised 9-25-09.doc 6.Vo-IZ- Date 'r WEDDLE SURVEYING MAPPING, INC. Boundary- Construction -Topographic -Aerial Surveys- ALTA Surveys - GPS - Consulting November 8, 2012 Mr. Timothy R. Jonasson Public Works Director / City Engineer City of La Quinta 78-495 Calle Tampico La Quinta, CA 92253-1504 Re: Pad/Form Grade Verification City of La Quinta CVETAS RESIDENCE Lot 248 Tract No. 29894-2 Amnd. 53-351 Via Strada HIDEAWAY APN 777-180-014 Dear Mr. Jonasson: We have performed a field survey to determine the vertical location of the Building Pad and Building Form for the above referenced project. The elevations observed are as follows: PAD (DESIGN) 1013.4' FORM (DESIGN) 1014.07' PAD (AS -BUILT) 1013.4' FORM (AS -BUILT) 1014.05' These field observations are in substantial conformance with the Precise Grading Plan prepared by ESSI SHAHANDEK CIVIL ENGINEER, dated 8/22/12, approved by the City of La Quinta Building & Safety Department and the building horizontal location substantially conforms to the required setbacks and site layout as shown on the approved site plan. Sincerely, VyEDDLE SURVEYING MAPPING, INC. David L. Weddle, President •L.S. 5570, exp 09/30/13 P.O. Box 10418 -Palm Desert, CA 92255-0418 77-725 Enfield Lane, Ste. 140- Palm Desert, CA 92211- 760.360.5570 E -Mail: WedSury@aol.com -Fax 760.360.5573 BUILDING ENERGY ANALYSIS REPORT PROJECT: Cvetas Residence Lot 248 The Hideaway La Quinta, Ca 92253 Project Designer: Fedderly and Associates 38-747 Nopales Road Palm Desert, Ca 92253 (760) 773-0875 Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 SEP 2 6 2012 11 d BY' 'LDA TY OF LAFUINTA Job Number: DING �OV ED P R CONSTRUCTION Date: 9/24/2012 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-24715:32:15 ID: w I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 12 HVAC System Heating and Cooling Loads Summary 15 Room Load Summary 20 Room Heating Peak Loads 25 Room Cooling Peak Loads 32 IEnergyPro 5.1 by Energysoft Job Number: ID: User Number: 6712 L] • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Cvetas Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/24/2012 Project Address Lot 248 The Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,128 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 5,431 Radiant Barrier New Wall Wood Framed R-21 6,263 New Slab Unheated Slab -on -Grade None 5,152 Perim = 523' New Floor Wood Framed w/o Crawl Space R-19 253 New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Front (E) 438.6 0.390 0.28 none none Bug Screen New Left (S) 467.5 0.390 0.28 none none Bug Screen New Right (N) 481.5 0.390 0.28 none none Bug Screen New Rear (W) 601.5 0.390 0.28 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 & 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 2 Large Gas 100 0.80 All Pipes Ins New Ener Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24715:32:15 ID: Page 3 of 40 • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Cvetas Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/24/2012 Project Address Lot 248 The Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,128 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Ot . Heating Min.. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Split Heat Pump 8.00 HSPF Split Heat Pump 14.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 6 Ductless/ with Fan Ductless n/a n/a New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24715:32:15 ID: Page 4 of 40 • • PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Building Type ® Single Family ❑ Addition Alone I Date Cvetas Residence ❑ Multi Family ❑ Existing+ Addition/Alteration 1912412012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford White #M-I-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details. HIGH MASS Design - Verify Thermal Mass: 335.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 2 HIGH MASS Design - Verify Thermal Mass: 48.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 2 HIGH MASS Design - Verify Thermal Mass: 169.0 ft2 Covered Slab Floor, 3.500" thick at Office The HVAC System HVAC 2 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 846.0 ft2 Covered Slab Floor, 3.500" thick at Master Bedroom HIGH MASS Design - Verify Thermal Mass: 256.0 ft2 Exposed Slab Floor, 3.500" thick at Master Bedroom The HVAC System HVAC 3 & 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 481.0 ft2 Covered Slab Floor, 3.500" thick at Living Dining HIGH MASS Design - Verify Thermal Mass: 2,214.0 ft' Exposed Slab Floor, 3.500" thick at Living Dining The HVAC System HVAC 5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. The HVAC System HVAC 6 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 803.0 ft2 Exposed Slab Floor, 3.500" thick at Garage HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 24APA724/58PH*045 includes credit for a 13.2 EER Condenser. A certified HERS rater must field verity the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA736/58PH*090 includes credit for a 13.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA760/58PH*110 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 & 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 3 & 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA736/58PH*090 includes credit for a 13.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ene Pro 5.1 b Ene Soft User Number: 6712 Run Code: 2012-09-24715:32:15 ID: Page 5 of 40 • • • PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Cvetas Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1912412012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof(R.38.2x 12.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix R44.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -411 form for each of the measures listed below for final to be given. The Cooling System MUZD30/MSZD30. includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 6 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24715:32:15 ID: Pa e 6 of 40 • • PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Cvetas Residence 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 1912412012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 5.90 5.76 0.14 Space Cooling 56.39 49.12 7.27 Fans 11.38 15.61 -4.23 Domestic Hot Water 5.60 3.68 1.92 Pumps 0.00 0.00 0.00 Totals 79.28 74.17 5.11 Percent Better Than Standard: 6.4% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 2,023 439 Fuel Available at Site: Natural Gas (S) 2,066 468 Raised Floor Area: 253 (►M 2,006 602 Slab on Grade Area: 5,152 (N) 2,157, 482 Average Ceiling Height: 12.1 Roof 5,431 0 Fenestration Average U -Factor: 0.39 TOTAL: 1.989 Average SHGC: 0.28 Fenestration/CFA Ratio: 32.5% REMARKS Lot248 @ -The Hideaway STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 9/24 012 Address 77-085 Michigan Drive Name Jon Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Fedderty and Associates Address 38-747 Nopales Road Name Fedderty and Associates City/State/Zip Palm Desert, Ca 92253 Phone (760) 773-0875 Signed License # Date EnerovPro 5.1 by Ener Soft User Number: 6712 RunCode: 2012-09-24715:32:15 /D: Page 7 of 40 C] • • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Cvetas Residence Building Type m Single Family ❑Addition Alone 11Multi Family 11Existing+ Addition/Alteration Date 1912412012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix I Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 383 0.026 R-38 0 0 New 4.2.1-A9 Bedroom 2 Wall 80 0.069 R-21 0 90 New 4.3.1-A6 Bedroom 2 Wall 120 0.069 R-21 90 90 New 4.3.1-A6 Bedroom 2 Wall 148 0.069 R-21 180 90 New 4.3.1-A6 Bedroom 2 Slab 335 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 Slab 48 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 Roof 169 0.026 R-38 0 0 New 4.2.1-A9 Office Wall 85 0.069 R-21 0 90 New 4.3.1-A6 Office Wall 104 0.069 R-21 90 90 New 4.3.1-A6 Office Wall 60 0.069 R-21 180 90 New 4.3.1-A6 office Wall 70 0.069 R-21 270 90 New 4.3.1-A6 office Slab 169 0.730 None 0 180 New 4.4.7-A1 office Roof 1,102 0.026 R-38 0 0 New 4.2.1-A9 Master Bedroom Wall 96 0.069 R-21 0 90 New 4.3.1-A6 Master Bedroom Wall 84 0.069 R-21 90 90 New 14.3.1-A6 Master Bedroom Wall 441 0.069 R-21 180 90 New 14.3.1-A6 JMaslerBedroom FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Window 35.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Bedroom 2 2 Window 32.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Bedroom 2 3 Window 32.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Bedroom 2 4 Window 8.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Bedroom 2 5 Window 40.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Office 6 Window 21.2 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Office 7 Window 40.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Office 8 Window 24.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Master Bedroom 9 Window 84.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Master Bedroom 10 Window 36.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Master Bedroom 11 Window 84.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Master Bedroom 12 Window 15.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Master Bedroom 13 Window 120.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Master Bedroom 14 Window 40.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Living Dining 15 Window 27.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Living Dining 16 Window 40.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Living Dining (1) 1.1 -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hat Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len I Hat Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Buq Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bu Screen 0.76 16 Bu Screen 0.76 EnerqyFro 5.1 by EnerqySoft User Number.' 6712 RunCode: 2012-09-24715:32:15 ID: Page 8 of 40 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R Project Name Cvetas Residence Building Type m Single Family ❑Addition Alone 13Multi Family 13Existing+ Addition/Alteration Date 1912412012 OPAQUE SURFACE DETAILS Surface Type Area U Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 180 0.069 R-21 270 90 New 4.3.1-A6 Master Bedroom Slab 846 0.730 None 0 180 New 4.4.7-A 1 Master Bedroom Slab 256 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Roof 2,504 0.026 R-38 0 0 New 4.2.1-A9 Living Dining Wall 693 0.069 R-21 0 90 New 4.3.1-A6 Living Dining Wall 754 0.069 R-21 90 90 New 4.3.1-A6 Living Dining Wall 276 0.069 R-21 180 90 New 4.3.1-A6 Living Dining Wall 777 0.069 R-21 270 90 New 4.3.1-A6 Living Dining Slab 481 0.730 None 0 180 New 4.4.7-A1 Living Dining Slab 2,214 0.730 None 0 180 New 4.4.7-A1 Living Dining Roof 545 0.026 R-38 0 0 New 4.2.1-A9 Bedroom 3 2nd Flr Wall 318 0.069 R-21 0 90 New 4.3.1-A6 Bedroom 3 2nd Fir Wall 310 0.069 R-21 90 90 New 4.3.1-A6 Bedroom 3 2nd Flr Wall 228 0.069 R-21 180 90 New 4.3.1-A6 Bedroom 3 2nd Fir Wall 120 0.069 R-21 27090 1 New 14.3.1-A6 Bedroom 3 2nd Flr Floor 253 0.048,R-19 0 180 1 New 4.4.2-A4 JBedroom 3 2nd Flr FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 12.5 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Living Dining 18 Window 40.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Living Dining 19 Window 40.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Living Dining 20 Window 40.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Living Dining 21 Window 58.2 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Living Dining 22 Window 48.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Living Dining 23 Window 58.2 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Living Dining 24 Window 32.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Living Dining 25 Window 22.5 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Living Dining 26 Window 38.5 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Living Dining 27 Window 38.5 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Living Dining 28 Window 21.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Living Dining 29 Window 260.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Living Dining 30 Window 38.5 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Living Dining 31 Window 40.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Living Dining 32 Window 27.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Living Dining (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window LhgL Wd Ove hang Left Fin Right in Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 lBug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 JBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24715:32:15 ID: Page 9 of 40 • C7 C] CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R Project NameBuilding Cvetas Residence 7❑ Type m Single Family ❑ Addition Alone Multi Family ❑ Existing+ Addition/Alteration Date 1912412012 OPAQUE SURFACE DETAILS Surface Type Area U Insulation Joint Appendix Factor Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments Roof 427 0.026 R-38 0 0 New 4.2.1-A9 Bedroom 4 2nd Fir Wall 184 0.069 R-21 0 90 New 4.3.1-A6 Bedroom 4 2nd Flr Wall 220 0.069.R-21 180 90 New 4.3.1-A6 Bedroom 4 2nd Flr Wall 168 0.069 R-21 270 90 New 4.3.1-A6 Bedroom 4 2nd Fir Roof 301 0.026 R-38 0 0 New 4.2.1-A9 Garage Wall 220 0.069 R-21 0 90 New 4.3.1-A6 Garage Wall 213 0.069 R-21 90 90 New 4.3.1-A6 Garage Wall 226 0.069 R-21 180 90 New 4.3.1-A6 Garage Wall 90 0.069,R-21 270 90 1 New 4.3.1-A6 Garage Slab 803 0.730 None 0 180 New 4.4.7-A1 Garage FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 24.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Living Dining 34 Window 10.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Bedroom 3 2nd Flr 35 Window 8.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Bedroom 3 2nd FIr 36 Window 10.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Bedroom 3 2nd Flr 37 Window 1 8.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Bedroom 3 2nd Flr 38 Window 8.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Bedroom 3 2nd Flr 39 Window 36.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Bedroom 3 2nd Fir 40 Window 8.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Bedroom 4 2nd Flr 41 Window 8.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Bedroom 4 2nd Flr 42 Window 42.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Bedroom 4 2nd Flr 43 Window 10.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Bedroom 4 2nd Flr 44 Window 144.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Garage 45 Window 64.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Garage 46 Window -9-6-0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Garage 47 Window 10.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Garage 48 Window 10.0 0.390 NFRC 0.28 /7F --RC1 180 New Dual non Metal Tinted Garage (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 lBug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 JBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2012-09-24715:32:15 ID: Pae 10 of 40 • • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5) CF -1 R Project Name Cvetas Residence Building Type ❑Single Family ❑Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration2412012 ate T/_ BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built HVAC 1 Bedroom 2 383 3,830 Once 169 1,690 HVAC 2 Master Bedroom 1,102 13,224 HVAC 3 & 4 Living Dining 2,695 37, 730 HVAC 5 Bedroom 3 2nd Flr 545 5,450 Bedroom 4 2nd Flr 427 4,270 HVAC 6 Garage 807 8,070 Totals 6,1281 01 01 0 HVAC SYSTEMS System Name Qty. Heating Type_ Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 2 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 3 & 4 2 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC 5 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 6 1 Split Heat Pump 18.00 HSPF I Split Heat Pump 14.5 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 3 & 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 d New HVAC 5 1 Ducted I Ducted I Attic, Ceiling Ins, vented 1 8.01 El I New HVAC 6 1 Ductless /with Fan Ductless n/a n/a 1 ❑ INew WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford White #M-1-100TI 2 Large Gas All Pipes Ins 85,000 100 0.80 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ff c 0 m a — System Name Pipe Len th Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24715:32:15 ID: Pae 11 of 40 • MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Cvetas Residence Date 9/24/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent LI -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. §150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. y 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release -valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of 113(c)5. . §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine Iines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance, and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode. 2012-09-24T15:32:15 ID: Page 12 of 40 C MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Cvetas Residence 9/24/2012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation -required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130 d . §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24715:32:15 ID: Page 13 of 40 C C MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Cvetas Residence 1912412012 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that .they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable I requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. I EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24715:32:15 /D: Page 14 of 40 C C C HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Cvetas Residence Date 9/24/2012 System Name HVAC 1 Floor Area 552 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 361 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible I Latent CFM Sensible Output per Sys 51,000 9,229 863 176 11,008 Total Output Btuh 51,000 0 Output Btuh/s ft 92.4 435 420 Cooling System 0 0 Output per System 25,200 0 0 0 0 Total Output Btuh 25,200 0 863 0 Total Output ons 2.1 435 420 Total Output Btuh/s ft 45.7 Total Output s ft/Ton 262.9 1 10,0991 11,849 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Carrier 24APA724/58PH'045 21,331 0 51,000 Airflow cfm/s ft 1.45 Total Adjusted System Output 1 21,331 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 0 1 51,000 Aug 3 PM Jan 1 AM Airflow cfm/Ton 381.0 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 cfm Supply Fan 800 cfm 70 OF 70 OF 129 OF Heating Coil 129 OF ROOM --M i - 70 OF .COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 79162 Outside Air Ar 0 cfm 791 62 °F OF 79/62°F 53/52°F Supply Fan Cooling Coil i 54 / 52 OF 800 cfm 39.8% 1 ROOM III 78 / 62 OF LELIA EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24715:32:15 /D: Page 15 of 40 C C HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Cvetas Residence Date 9/24/2012 System Name HVAC 2 Floor Area 1,102 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 610 Return Vented Lighting Return Air Ducts Return Fan Ventilation F 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent I CFM Sensible Output per System 89,000 14,528 1,124 225 16,455 Total Output Btuh 89,000 0 Output Btuh/s ft 80.8 685 628 Cooling System 0 0 Output per System 36,600 0 0 0 0 Total Output Btuh 36,600 0 1,124 0 Total Output ons 3.1 685 628 Total Output Btuh/s ft 33.2 Total Output s ft/Ton 361.3 1 15,897 17,711 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24APA736/58PH'090 29,945 1,438 89,000 Airflow cfm/s ft 1.09 Total Adjusted System Output 29,945 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1,438 89,000 Aug 3 PM Jan 1 AM Airflow cfm/Ton 393.4 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions -HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 70 OF 70 OF 139 OF 139 OF f0 Heating Coil Supply Fan 139 OF 1,200 cfm ROOM In 70 OF ;COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 0 cfm 79163 of 4 79/63°F 55/54°F 55/54°F Cooling Coil Supply Fan 56 / 54 OF 1,200 cfm 42.3% ROOM 78/ 63 OF J— EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2012-09-24715:32:15 ID: Page 16 of 40 • 174 174 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Cvetas Residence Date 9/24/2012 System Name HVAC 3 & 4 Floor Area 2,695 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 1,881 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent I CFM Sensible Output perSys tem 110,000 42,109 2,459 796 43,137 Total Output Btuh 220,000 0 Output Btuh/s ft 81.6 1,984 1,647 Cooling System o 0 Output erSystem 59,000 0 0 0 0 Total Output Btuh 118,000 0 2,459 0 Total Output ons 9.8 1 1,984 1,647 Total Output(Bt uh/s ft 43.8 Total Output s ft/Ton 274.1 1 46,078 46,430 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 4,000 Carrier 24APA760/58PH'110 93,493 8,731 220,000 Airflow cfm/s ft 1.48 Airflow cfm/Ton 406.8 Outside Air % 0.0% Total Adjusted System Output 1 93,493 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 8,731 Aug 3 PM 1 220,000 I Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions -HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF 0 Outside Air 0 cfm Supply Fan 4,000 cfm 70 OF 70 OF 121 OF Heating Coil � A 121 OF -•• L_..._ROOM M 70 OF =01-ING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 78/63°F 78/63°F 57/55°F o �_ Outside Air W Z 0 cfm Supply Fan Cooling Coil 57 / 55 OF 4,000 cfm ' 44.4% ROOM 78 / 63 OF 78 / 63 OF EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2012-09-24715:32:15 ID: Page 17 of 40 -HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Cvetas Residence Date 9/24/2012 System Name HVAC 5 Floor Area 972 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 471 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 89,000 11,296 1,215 165 12,099 Total Output Btuh 89,000 0 Output Btuh/s ft 91.6 532 462 Cooling System 0 0 Output perSystem 36,600 0 0 0 0 Total Output Btuh 36,600 0 1,215 0 Total Output ons 3.1 532 462 Total Output Btuh/s ft 37.7 Total Output s ft/Ton 318.7 1 12,361 13,022 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Carrier 24APA736/58PH'090 29,841 1,529 89,000 Airflow cfm/s ft 1.23 Total Adjusted System Output 29,841 (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 1,529 89,000 Aug 3 PM Jan 1 AM Airflow cfm/Ton 393.4 Outside Air % 0.0% Outside Air cfm/s ft 0.00 I- Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air -4 r- 0 cfm 70 OF 70 OF 139 OF 139 OF Pi— Heating Coil Supply Fan 139 OF 1,200 cfm ROOM 70 OF 77 = COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air Ar 0 cfm 78 / 63 of I 78/63°F 55/54°F 55/54°F Cooling Coil Supply Fan 55154 OF 1,200 cfm 42.3% ROOM t 78/ 63 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24715:32:15 ID: Page 18 of 40 0 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Cvetas Residence Date 9/24/2012 System Name HVAC 6 Floor Area 807 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 483 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per Sys 32,600 12,232 770 679 13,829 Total Output Btuh 32,600 0 Output Btuh/s ft 40.4 0 0 .Cooling System 0 0 Output per System 30,700 0 0 0 0 Total Output Btuh 30,700 0 0 1 12,232 770 0 Total Output Tons 2.6 0 Total Output Btuh/s ft 38.0 Total Output s ft/Ton 315.4 1 13,829 Air System CFM per System 1,000 HVAC EQUIPMENT SELECTION Airflow cfm 1,000 MUZD30/MSZD30 25,336 704 20,361 Airflow cfm/s ft 1.24 Total Adjusted System Output 1 25,3361 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 704 1 20,361 Aug 3 PM Jan 1 AM Airflow cfm/Ton 390.9 Outside Air °i°' 0.0 % Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 cfm Supply Fan 1,000 cfm 70 OF 70 OF 89 OF Heating Coil 89 OF ............ ................................. _......... ROOM 70 OF -COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112178 °F 78 / 62 OF 78 / 62 OF 54 / 53 OF o Outside Air 0 cfm Supply Fan Cooling Coil 54 / 53 OF 1,000 cfm ROOM 40.7 78 162 OF 78 ! 62 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24715:32:15 ID: Page 19 of 40 ROOM LOAD SUMMARY Project Name Date Cvetas Residence 9/24/2012 HVAC 1 552 Zone Name I Room Name Mult. I CFM I Sensible I Latent I CFM I Sensible I Latent I CFM I Sensible Bedroom 2 1 Bedroom 2 1 1 1901 4,8681 5211 1901 4,8681 5211 971 6,106 Office I Office 1 1 1711 4,3621 3421 1711 4,3621 3421 781 4,902 PAGE TOTAL TOTAL' 361 9,229 863 176 11,008 361 9,229 863 176 11,008 Total includes ventilation load for zonal systems. EnergyPro 5.1 by EnerqySoft User Number., 6712 Run Code: 2012-09-24T15:32:15 ID: Page 20 of 40 C] • W ROOM LOAD SUMMARY Project Name Date Cvetas Residence 9/24/2012 System Name Floor Area HVAC 2 1,102 SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Master Bedroom Master Bedroom 1 610 14,528 1,124 610 14,528 1,124 225 16,455 PAGE TOTAL TOTAL• 610 14,528 1,124 225 16,455 610 14,5281 1,124 225 16, 455 Total includes ventilation load for zonal systems. EnerovPro 5.1 by EneravSoft User Number: 6712 RunCode: 2012-09-24715:32:15 ID: Pape 21 of 40 • • ROOM LOAD SUMMARY Project Name Date Cvetas Residence 9/24/2012 System Name Floor Area HVAC 3 & 4 2,695 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name I Mult. I CFM Sensible I Latent I CFM I Sensible Latent CFM I Sensible Living Dining Living Dining I 1 1 1,8811 4Z 1091 2,459 1,8811 4Z 1091 2,459 7961 43,137 PAGE TOTAL TOTAL* 1,881 42,109 2,459 796 43,137 1,881 42,109 2,459 796 43,137 * Total includes ventilation load for zonal systems. Ener Pro 5.1 by Ener Soft User Number: 6712 Run Code: 2012-09-24715:32:15 ID: Page 22 of 40 • • ROOM LOAD SUMMARY Project Name Date Cvetas Residence 9/24/2012 System Name Floor Area HVAC 5 972 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Bedroom 3 2nd Flr Bedroom 3 2nd Flr 1 262 6,291 657 262 6,291 657 99 7,295 Bedroom 4 2nd Fir Bedroom 4 2nd Fir 1 2091 5,005 558 209 5,005 5581 65 4,803 PAGE TOTAL TOTAL' 471 11,296 1,215 165 12,099 471 11,296 1,215 165 12,099 Total includes ventilation load for zonal systems. EnemvPro 5.1 by Enem ySoft User Number., 6712 RunCode: 2012-09-24715:32:15 ID: Pa a 23 of 40 • • ROOM HEATING PEAK LOADS Project Name7912412012 Cvetas Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 Floor Area 383.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value 383.0 X 0.0260 348.0 X 0.0690 107.0 X 0.3900 perm = 47.0 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to another room X 383 X 10.00 X 0.424 Area Ceiling Height ACH X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F Btu/hr R-38 Roof(R.38.2x 12.16) 44 = 438 R-21 Wall (W.21.2x6.16) 44 = = = 1,057 Dual non Metal Tinted 44 1,836 Slab -On -Grade 44 1,510 = = = = = = = = = = = = = = = = Page Total /60] X 44 AT Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction 1 4,840 = 1,266 [TOTAL HOURLY HEAT LOSS FOR ROOM 6,106 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24T15:32:15 ID: Page 25 of 40 • • • ROOM HEATING PEAK LOADS Project Name Date Cvetas Residence 9/24/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Office Time of Peak Jan 1 AM Floor Area 169.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr R-38 Roof(R.38.2x 12.16) 169.0 X 0.0260 X 44 = 193 R-21 Wall (W.21.2x6.16) 318.8 X 0.0690 X 44 = 968 Dual non Metal Tinted 101.2 X 0.3900 X 44 = 1,737 Slab -On -Grade perm = 45.0 X 0.7300 X 44 = 1,445 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 4,343 Infiltration:[ 1.00 X 1.064 X 169 X 10.00 X 0.424 /60] X 44 = 559 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 4,902 EnergyPro 5.1 by EnergySoR User Number: 6712 Run Code: 2012-09-24715:32:15 ID: Page 26 of 40 • • ROOM HEATING PEAK LOADS Project Name Cvetas Residence Date 9/24/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Floor Area 1,102.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area R-38 Roof(R. 38.2x 12.16) 1,102.0 X R-21 Wall (W.21.2x6.16) 801.0 X Dual non Metal Tinted 363.0 X Slab -On -Grade perm = 90.0 X X X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to Infiltration:[ 1.00 X 1.064 X 1,102 X Schedule Air Sensible Area Ceiling Fraction U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr 0.0260 44 1,261 0.0690 44 2,432 0.3900 44 6,229 0.7300 44 2,891 another room 12.00 X 0.353 Height ACH Page Total /60] X AT 12.812 = 3,643 TOTAL HOURLY HEAT LOSS FOR ROOM 16,455 Energ Pro 5.1 by EnergySoft User Number. 6712 Run Code: 2012-09-24715:32:15 ID: Page 27 of 40 • • • ROOM HEATING PEAK LOADS Project Name7912412012 Cvetas Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Living Dining Floor Area 2,695.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0260 X 0.0690 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF Btu/hr = 2,865 = 7,584 = 16,232 = 7,548 = = = = = = = = = = = = = = = = = = = = = = = = 34,229 44 = 8,908 R-38 Roof(R.38.2x 12.16) 2,504.0 44 R-21 Wall (W.21.2x6.16) 2,498.1 44 Dual non Metal Tinted 945.9 X X 0.3900 44 Slab -On -Grade penim = 235.0 0.7300 44 X X X X X X X X X X X X X X X X X X X X X X X X X X X to another room 14.00 X 0.303 Ceiling Height ACH Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 2,695 X Area Page Total /60] X AT TOTAL HOURLY HEAT LOSS FOR ROOM 43,137 EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2012-09-24715:32:15 ID: Page 28 of 40 • ROOM HEATING PEAK LOADS Project Name Cvetas Residence Date 9/24/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 3 2nd Flr Floor Area 545.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value 0.0260 X 0.0690 X 0.3900 X 0.0480 X X X X X X X X X X X X X X X X X X X X X X X X X X X X another room 10.00 X 0.424 Height ACH AT OF = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof(R.38.2x 12.16) 545.0 44 623 R-21 Wall (W.21.2x6.16) 976.0 44 2,963 Dual non Metal Tinted 80.0 44 1,373 R-19 Floor No Crawlspace 253.0 44 534 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 545 X Area Page Total /60] X AT 5,494 = 1,801 TOTAL HOURLY HEAT LOSS FOR ROOM 7,295 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24T15:32:15 ID: Page 29 of 40 • • • ROOM HEATING PEAK LOADS Project Name7912412012 Cvetas Residence ate ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 4 2nd Flr Floor Area 427.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF Btu/hr 44 = 488 44 = 1,737 44 = 1,167 = = = = = = = = = = = = = = = = = = = = = = = = = Page Total 3,392 /60] X 44 = 1,411 AT R-38 Roof(R.38.2x12.16) 427.0 0.0260 R-21 Wall (W.21.2x6.16) 572.0 0.0690 Dual non Metal Tinted 68.0 0.3900 Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 427 X Area another room 10.00 X 0.424 Height ACH TOTAL HOURLY HEAT LOSS FOR ROOM 4,803 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24T15:32:15 ID: Page 30 of 40 9 • U ROOM HEATING PEAK LOADS Project Name Cvetas Residence Date 9/24/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Garage Floor Area 807.0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof(R.38.2x 12.16) 301.0 X 0.0260 44 344 R-21 Wall (W.21.2x6.16) 749.0 X X X X X X 0.0690 44 2,274 Dual non Metal Tinted 324.0 0.3900 44 5,560 Slab -On -Grade perm = 106.0 0.7300 44 3,405 X X X X X X X X X X X X X X X X X X XX X X X X X to another room 10.00 X 0.357 Ceiling Height ACH Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 807 X Area Page Total /60] X AT 11,583 = 2,246 TOTAL HOURLY HEAT LOSS FOR ROOM 13 829 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24715:32:15 ID: Page 31 of 40 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Cvetas Residence 9/24/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 383.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x 12.16) (N) 383.0 X 0.0260 X 56.0 = 558 R-21 Wall (W.21.2x6.16) (N) 80.0 X 0.0690 X 23.0 = 127 R-21 Wall (W.21.2x6.16) (E) 120.0 X 0.0690 X 33.0 = 273 R-21 Wall (W.21.2x6.16) (S) 148.0 X 0.0690 X 26.0 = 266 X X = X X = X X = X X = X J X I= Page Total 1,223 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr K-1 (E) 0.0 X 18.2 + 35.0 X 34.8 = 1,218 N-2 (S) 0.0 X 18.2 + 32.0 X 18.3 = 584 N-3 (S) 0.0 X 18.2 + 32.0 X 18.3 = 584 0-4 (S) 0.0 X 18.2 + 8.0 X 18.3 = 146 X + X = X + X - X + X = X + X - X +1 X - Page Total 2,533 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.16 X 20.96 X 34 = 881 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 4,868 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 1 Btuh/occ. = 200 Infiltration: 4,771 X 1.16 X 20.96 X 0.00276 = 321 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 521 EnerqvPm 5.1 by Energ Soft User Number: 6712 RunCode: 2012-09-24715:32:15 /D: Page 32 of 40 C: L-] RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Cvetas Residence 9/24/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Office Outdoor Dry Bulb Temperature 112 OF Floor Area 169.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x 12.16) (N) 169.0 X 0.0260 X 56.0 = 246 R-21 Wall (W.21.2x6.16) (N) 85.0 X 0.0690 X 23.0 = 135 R-21 Wall (W.21.2x6.16) (E) 103.8 X 0.0690 X 33.0 = 236 R-21 Wall (W.21.2x6.16) (S) 60.0 X 0.0690 X 26.0 = 108 R-21 Wall (W.21.2x6.16) (W) 70.0 X 0.0690 X 33.0 = 159 X X = X X = X X = X X = Page Total 884 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 9-5 (N) 0.0 X 18.2 + 40.0 X 18.2 = 728 L-6 (E) 0.0 X 18.2 + 21.2 X 34.8 = 738 9-7 (W) 0.0 X 18.2 + 40.0 X 34.8 = 1,393 X + X - X + X - X + X - X + X - X + X - X +1 X - Page Total 2,858 Internal Gain Btu/hr- tu/hrOccu ants Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = o Infiltration: 1.064 X 1.16 X 9.25 X 34 = 389 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 4,362 Latent Gain Btu/hr Occupants 10 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 1.16 X 9.25 X 0.00276 = 142 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 342 EnemvPro 5.1 by EnerqvSoft User Number: 6712 Run Code: 2012-09-24T15:32:15 ID: Page 33 of 40 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Cvetas Residence 1 9/24/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,102.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x12.16) (N) 1,102.0 X 0.0260 X 56.0 = 1,605 R-21 Wall (W.21.2x6.16) (N) 96.0 X 0.0690 X 23.0 = 152 R-21 Wall (W.21.2x6.16) (E) 84.0 X 0.0690 X 33.0 = 191 R-21 Wall (W.21.2x6.16) (S) 441.0 X 0.0690 X 26.0 = 791 R-21 Wall (W.21.2x6.16) (W) 180.0 X 0.0690 X 33.0 = 410 X X = X X = X X = X X = Page Total 3,149 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 5-8 (N) 0.0 X 18.2 + 24.0 X 18.2 = 437 8-9 (S) 0.0 X 18.2 + 84.0 X 18.3 = 1,533 R-10 (S) 0.0 X 18.2 + 36.0 X 18.3 = 657 8-11 (S) 0.0 X 18.2 + 84.0 X 18.3 = 1,533 C-12 (S) 0.0 X 18.2 + 15.0 X 18.3 = 274 3-13 (W) 0.0 X 18.2 + 120.0 X 34.8 = 4,178 X + X = X + X = X 1 +1 X = Page Total 8,612 Internal Gain Btu/hr- tu/hrOccu Occupants ants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.16 X 60.30 X 34 = 2,536 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,528 Latent Gain Btu/hr Occupants 10 Occupants X 200 Btuh/occ. = 200 Infiltration: x,771 X 1.16 X 60.30 X 0.00276 = 924 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,124 EnemvPro 5.1 by Enem Soft User Number: 6712 RunCode: 2012-09-24715:32:15 ID: Page 34 of 40 • • 40 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Cvetas Residence 9/24/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 2,695.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temaerature 78 OF Outdoor Dailv Range: 34 OF Opaque Surfaces R-38 Roof(R.38.2x12.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W. 21.2x6.16) I on (N) (E) (S) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = Z504.0 0.0260 56.0 692.5 0.0690 23.0 753.6 0.0690 33.0 275.5 0.0690 26.0 776.5 0.0690 33.0 18.2 12.5 18.2 0.0 18.2 40.0 18.2 0.0 18.2 40.0 J 0.0 18.2 40.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration H-14 G-15 E-16 P-17 B-18 B-19 B-20 A-21 1-22 CArientation (N) (N) (N) (N) (N) (N) (N) (E) (E) Btu/hr 3,646 11099 1,716 494 1 1,7681 1 8,7231 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 18.2 40.0 18.2 0.0 18.2 27.0 18.2 0.0 18.2 40.0 18.2 0.0 18.2 12.5 18.2 0.0 18.2 40.0 18.2 0.0 18.2 40.0 18.2 0.0 18.2 40.0 18.2 0.0 18.2 58.2 34.8 0.0 18.2 48.0 34.81 Page Total Btu/hr 728 491 728 227 728 728 728 1,671 8,0541 Internal Gain E771 230 Btuh/occ. Occupants 1•0 Occupants X = Equipment 0.0 Dwelling Unit X 1,600 Btu = I Infiltration: 1.064 X 1.16 X 147.47 X 34 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 42,109 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 1.16 X 147.47 X 0.00276 = 2.259 Air Sensible CFM ELA AW 0 • is I RESIDENTIAL ROOM COOLING LOAD SUMMARY Cvetas Residence 9/24/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 2,695.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Dailv Ranoe: 34 OF Surfaces Orientation Area U -Factor CLTD' X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded FPnP_Stratinn A-23 M-24 D-25 J-26 J-27 6-28 2-29 J-30 4-31 Orientation Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 18.2 58.2 34.8 0.0 18.2 32.0 34.8 0.0 18.2 22.5 18.3 0.0 18.2 38.5 18.3 0.0 18.2 38.5 18.3 0.0 18.2 21.0 18.3 0.0 18.2 260.0 34.8 0.0 18.2 38.5 34.8 0.0 18.2 40.0 34.81 Page Total Btu/hr 01 Btu/hr 2,026 1,114 411 703 703 383 9,052 1,340 1,393 17.125 Internal Gain Btu/hr Occupants 1.0 Occupants X 230Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.16 X 147.47 X 34 = 6,202 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 42,1091 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 1 Btuh/occ. = 200 Infiltration: 4,771 X 1.16 X 147.47 X 0.00276 = 2,259 Air Sensible CFM ELA AW AL HOURLY LATENT HEAT 4 0 V • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Cvetas Residence 9/24/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 2,695.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr G-32 (KO 0.0 X 18.2 + 27.0 X 34.8 = 940 F-33 W 0.0 X 18.2 + 24.0 X 34.8 = 836 X + X = X + X - X + X - X + X - X + X = X + X = X +1 X = Page Total 1,776 Internal Gain Btu/hr— tu/hrOccu ants Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.16 X 147.47 X 34 = 6,202 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 42,109 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 1.16 X 147.47 X 0.00276 = 7259 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,459 Ene Pro 5.1 bv EnerovSoft User Number: 6712 RunCode: 2012-09-24T15:32:15 ID: Pace 37 of 40 I d 9 1 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Cvetas Residence 9/24/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 3 2nd Flr Outdoor Dry Bulb Temperature 112 OF Floor Area 545.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R. 38.2x 12.16) (N) 545.0 X 0.0260 X 56.0 = 794 R-21 Wall (W.21.2x6.16) (N) 318.0 X 0.0690 X 23.0 = 505 R-21 Wall (W.21.2x6.16) (E) 310.0 X 0.0690 X 33.0 = 706 R-21 Wall (W.21.2x6.16) (S) 228.0 X 0.0690 X 26.0 = 409 R-21 Wall (W.21.2x6.16) M9 120.0 X 0.0690 X 33.0 = 273 R-19 Floor No Crawlspace 253.0 X 0.0480 X 19.0 = 231 X X = X X = X J X I= Page Total 1 2,917 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 3-34 (N) 0.0 X 18.2 + 10.0 X 18.2 = 182 3-35 (N) 0.0 X 18.2 + 8.0 X 18.2 = 146 3-36 (E) 0.0 X 18.2 + 10.0 X 34.8 = 348 3-37 (E) 0.0 X 18.2 + 8.0 X 34.8 = 279 3-38 (E) 0.0 X 18.2 + 8.0 X 34.8 = 279 3-39 (S) 0.0 X 18.2 + 36.0 X 18.3 = 657 X + X - X + X - X + X - Page Total 1,890 Internal Gain Btu/hr- tu/hrOccu ants Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = o Infiltration: 1.064 )( 1.16 X 29.82 X 34 = 1,254 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,291 Latent Gain Btu/hr Occupants 10 Occupants X 200 Btuh/occ. = 200 Infiltration: 4.771 X 1.16 X 29.82 X 0.00276 = 457 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 657 EnergyPro 5.1 by EnerqvSoft User Number: 6712 RunCode: 2012-09-24715:32:15 /D: Page 38 of 40 CJ Ll RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Cvetas Residence 11 9/24/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 4 2nd Flr Outdoor Dry Bulb Temperature 112 OF Floor Area 427.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x 12.16) (N) 427.0 X 0.0260 X 56.0 = 622 R-21 Wall (W.21.2x6.16) (N) 184.0 X 0.0690 X 23.0 = 292 R-21 Wall (W.21.2x6.16) (S) 220.0 X 0.0690 X 26.0 = 395 R-21 Wall (W.21.2x6.16) (W) 168.0 X 0.0690 X 33.0 = 383 X X = X X = X X = X X = X X = Page Total 1,691 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr- 3-40 (N) 0.0 X 18.2 + 8.0 X 18.2 = 146 3-41 (N) 0.0 X 18.2 + 8.0 X 18.2 = 146 3-42 (W) 0.0 X 18.2 + 42.0 X 34.8 = 1,462 3-43 (lM 0.0 X 18.2 + 10.0 X 34.8 = 348 X + X - X + X - X + X = X + X - X +1 X = Page Total 2,101 Internal Gain Btu/hr- tu/hrOccu ants Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.16 X 23.37 X 34 = 983 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 5,005 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. _ 200 Infiltration: 4,771 X 1.16 X 23.37 X 0.00276 = 358 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 558 EnergyPro 5.1 by EnerqvSoft User Number.- 6712 RunCode: 2012-09-24715:32:15 ID: Page 39 of 40 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Cvetas Residence 9/24/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Garage Outdoor Dry Bulb Temperature 112 OF Floor Area 807.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R. 38.2x 12.16) (N) 301.0 X 0.0260 X 56.0 = 438 R-21 Wall (W.21.2x6.16) (N) 220.0 X 0.0690 X 23.0 = 349 R-21 Wall (W.21.2x6.16) (E) 213.0 X 0.0690 X 33.0 = 485 R-21 Wall (W.21.2x6.16) (S) 226.0 X 0.0690 X 26.0 = 405 R-21 Wall (W.21.2x6.16) (149 90.0 X 0.0690 X 33.0 = 205 X X = X X = X X = X X = Page Total 1,883 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 1944 (N) 0.0 X 18.2 + 144.0 X 18.2 = 2,619 2045 (E) 0.0 X 18.2 + 64.0 X 34.8 = 2,228 W-46 (E) 0.0 X 18.2 + 96.0 X 34.8 = 3,342 N-47 (S) 0.0 X 18.2 + 10.0 X 18.3 = 183 N-48 (S) 0.0 X 18.2 + 10.0 X 18.3 = 183 X + X = X + X = X + X = X I + X = Page Total 8,555 Internal Gain Btu/hr- tu/hrOccu Occupants ants Occupants X 230 [;;:::d Btuh/occ. = 230 Equipment Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 1.16 X 37.19 X 34 = 1,564 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 12,232 Latent Gain Btu/hr Occupants 1•o Occupants X 200 Btuh/occ. _ 200 Infiltration: 4,771 X 1.16 X 37.19 X 0.00276 = 570 Air Sensible CFM EIA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 770 EnerqoPro 5.1 by EnerqvSoft User Number: 6712 Run Code: 2012-09-24715:32:15 ID: Pa a 40 of 40 ,,,Electronica,ly Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2012 Electronically Signed at CalCERTS.com by Robin Lever (Fedderly & Associates) 9/26/2012 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Cvetas Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/25/2012 Project Address Lot 248 The Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,128 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST 0 Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 5,431 Radiant Barrier New Wall Wood Framed R-21 6,263 New Slab Unheated Slab -on -Grade None 5,152 Perim = 523' New Floor Wood Framed w/o Crawl Space R-19 253 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (E) 438.6 0.390 0.28 none none Bug Screen New Left (S) 467.5 0.390---- 0.28 none none Bug Screen New Right (N) 481.5 0.390 0.28 none -E3Fnm yam Bug Screen New Rear (lAq 601.5 0.390 0- 0.2 Green New SAFETY D F_ ten• Z- ONSTRUCTION Yflu zu012 HVAC SYSTEMS Qty. Heating Min. Eff ' Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 2 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 & 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 2 Large Gas 100 0.80 All Pipes Ins New Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2012-09-24715:32:15 ID: Page 1 of 9 Reg: 212-NO04975OB-000000000-0000 Registration Date/Time: 2012/09/07 18:26:20 HERS Provider: CalCERTS, Inc Electronica}ly Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2012 Electronically Signed at Ca10ERTS.com by Robin Lever (Fedderly & Associates) 9/26/2012 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Cvetas Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/25/2012 Project Address Lot 248 The Hideaway La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 6,128 Addition n/a # of Stories 2 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Split Heat Pump 8.00 HSPF Split Heat Pump 14.5 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 6 Ductless / with Fan Ductless n/a n/a New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Energ Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24715:32:15 ID: Page 2 of 9 Reg: 212-NO04975OB-000000000-0000 Registration Date/Time: 2012/09/07 18:26:20 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2012 Electronically Signed at CalCERTS.com by Robin Lever (Fedderly & Associates) 9/26/2012 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Building Type ® Single Family ❑ Addition Alone Date Cvetas Residence 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 912512012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Bradford White #M-1-10OT68N is a non-NAECA large storage gas water heater. Verify DHW details. HIGH MASS Design - Verify Thermal Mass: 335.0 ft2 Covered Slab Floor, 3.500" thick at Bedroom 2 HIGH MASS Design - Verify Thermal Mass: 48.0 ft2 Exposed Slab Floor, 3.500" thick at Bedroom 2 HIGH MASS Design - Verify Thermal Mass: 169.0 ft2 Covered Slab Floor, 3.500" thick at Office The HVAC System HVAC 2 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 846.0 ft2 Covered Slab Floor, 3.500" thick at Master Bedroom HIGH MASS Design - Verify Thermal Mass: 256.0 ft2 Exposed Slab Floor, 3.500" thick at Master Bedroom The HVAC System HVAC 3 & 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 481.0 ft2 Covered Slab Floor, 3.500" thick at Living Dining HIGH MASS Design - Verify Thermal Mass: 2,214. 0 ft2 Exposed Slab Floor, 3.500" thick at Living Dining The HVAC System HVAC 5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. The HVAC System HVAC 6 must serve only Living Areas.? The non -closable area.between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow r6uirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 803.0 ft2 Exposed Slab Floor, 3.500" thick at Garage HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be 2iven. The Cooling System Carrier 24APA724/58PH*045 includes credit for a 13.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA736158PH*090 includes credit for a 13.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA760/58PH*110 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 & 4 incorporates HERS Verged Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 3 & 4 incorporates HERS verged Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 24APA736/58PH*090 includes credit for a 13.2 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro 5.1 by EnerqySoft User Number 6712 RunCode: 2012-09-24715:32:15 ID: Page 3 of 9 Reg: 212-NO04975OB-000000000-0000 Registration Date/Time: 2012/09/07 18:26:20 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2012 Electronically Signed at CalCERTS.com by Robin Lever (Fedderly & Associates) 9/26/2012 PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF -1 R Project Name Cvetas Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1912512012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof(R.38.2x12.16) includes credit fora Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS` REQUIRED�VERIFICATION • _.., - . % .•,' �; l i✓T 1 l �I M e-- Items in this section require field testi1'ngyand/ap••or verifidatioh by.a c.ertified'HERS Rater: -The inspector-must=rece�Jive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System MUZD30IMSZD30 includes credit for a 13.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 6 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. EnergyPro 5.1 by EnergySoft User Number 6712 RunCode: 2012-09-24715:32:15 ID: Pa e 4 of 9 Reg: 212-N0049750B-000000000-0000 Registration Date/Time: 2012/09/07 18:26:20 HERS Provider: CalCERTS, Inc ElectroniccIlly Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2012 Electronically Signed at CalCERTS.com by Robin Lever (Fedderly & Associates) 9/26/2012 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type 10 Single Family ❑ Addition Alone Date Cvetas Residence 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 9/25/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 5.90 5.76 0.14 Space Cooling 56.39 49.12 7.27 Fans 11.38 15.61 -4.23 Domestic Hot Water 5.60 3.68 1.92 Pumps 0.00 0.00 0.00 Totals 79.28 74.17 5.11 Percent Better Than Standard: 6.4% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 2,023 439 Fuel Available at Site: Natural Gas (S) 2,066 468 Raised Floor Area: 253 (KO 2,006 602 Slab on Grade Area: 5,152 (N) 2,157 482 Average Ceiling Height: 12.1 Roof 5,431 0 Fenestration Average U -Factor: 0.39 TOTAL: 1,989 Average SHGC: 0.28 Fenestration/CFA Ratio: 32.5 REMARKS Lot248 @ -The Hideaway ,v ��-! , �, L � J � .s l 1. ,4 ,,t �—.,i � � P• �� s � /� �y i j i v j STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, Address 77-085 Michigan Drive Name Tim Scott 9/25/2012 City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Si ned Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Fedderly and Associates Address 38-747 Nopales Road Name Fedderly and Associates City/State/Zip Palm Desert, Ca 92253 Phone (760) 773-0875 Signed License # Date Ene Pro 5.1 by Ene Soft User Number: 6712 RunCode: 2012-09-24715:32:15 ID: Pa - e 5 of 9 Reg: 212-NO04975OB-000000000-0000 Registration Date/Time: 2012/09/07 18:26:20 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2012 Electronically Signed at CalCERTS.com by Robin Lever (Fedderly & Associates) 9/26/2012 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Cvetas Residence Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 912512012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix I Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 3831 0.026 R-38 0 0 New 4.2.1-A9 Bedroom 2 Wall 80 0.069 R-21 0 90 New 4.3.1-A6 Bedroom 2 Wall 120 0.069 R-21 90 90 New 4.3.1-A6 Bedroom 2 Wall 148 0.069 R-21 180 90 New 4.3.1-A6 Bedroom 2 Slab 335 0.730 None 0 180 New 4.4.7-A 1 Bedroom 2 Slab 48 0.730 None 0 180 New 4.4.7-A1 Bedroom 2 Roof 169 0.026 R-38 0 0 New 4.2.1-A9 Office Wall 851 0.069 R-21 0 90 New 4.3.1-A6 Office Wall 1041 0.069 R-21 90 90 New 4.3.1-A6 Office Wall 601 0.069 R-21 180 90 New 4.3.1-A6 Office Wall 70 0.069 R-21 1 270 90 New 4.3.1-A6 Office Slab 169 0.730 None 0 180 New 4.4.7-A1 Office Roof 1,102 0.026 R-38 0 0 New 4.2.1-A9 Master Bedroom Wall 96 0.069 R-21 0 90 New 14.3.1-A6 I Master Bedroom Wall 84 0.069 R-21 90 90 New 4.3.1-A6 IMasterBedroorn Wall 44 1 0.069 R-21 180 90 New 4.3.1-A6 IMasterBedroom FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Window 35.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Bedroom 2 2 Window 32.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Bedroom 2 3 Window 32.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Bedroom 2 4 Window 8.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Bedroom 2 5 Window .� 40.0 0.390 NFRC 0.28 NFRC 10 New,__ .1 Dual non Metal Tinted _ Office 6 Window ` ,21.2 0.390 NFRC �y ! 0.28 NFRC )90 New E; Dual non Metal Tinted,' i Office 7 Window `40.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted, t ' Office 8 Window 24.0 --,'0.390 NFRC 0.28 NFRC -4 0 New y,.1 Dual non Metal Tinted Master Bedroom 9 Window 84.0 J 0.390 NFRC 0.28 NFRC V 180 New Dual non Metal Tinted '* Master Bedroom,., , 10 Window A)36.0 ) 0.390 NFRC i 0.28 NFRC 180 New.,,..) Dual non Metal Tinted y Master Bedroom 11 Window, 84.0 0.390 NFRC, :0.28 NFRC nf. 180 New Dual non Metal Tinted Master Bedroom le) 12 Window 15.0 0.390 NFRC - ,w 0.28 NFRC 180 New Dual non Metal Tinted Master Bedroom 13 Window 120.01 0.390 NFRC 0.28 NFRC 2701 New Dual non Meta! Tinted Master Bedroom 14 Window 40.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Living Dining 15 Window 27.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Living Dining 16 Window 40.0 0.390 NFRC 0.28 1 NFRC I 0 New I Dual non Metal Tinted Living Dining (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Overhang Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 JBug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number.' 6712 RunCode: 2012-09-24715:32:15 ID: Page 6 of 9 Reg: 212-NO04975OB-000000000-0000 Registration Date/Time: 2012/09/07 18:26:20 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2012 Electronically Signed at CalCERTS.com by Robin Lever (Fedderly & Associates) 9/26/2012 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Cvetas Residence Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 925/2012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 180 0.069 R-21 270 90 New 4.3.1-A6 Master Bedroom Slab 846 0.730 None 0 180 New 4.4.7-A1 Master Bedroom Slab 256 0.730 None 0 180 New 4.4.7-A 1 Master Bedroom Roof 2,5041 0.026 R-38 0 0 New 4.2.1-A9 Living Dining Wall 693 0.069 R-21 0 90 New 4.3.1-A6 Living Dining Wall 754 0.069 R-21 90 90 New 4.3.1-A6 Living Dining Wall 276 0.069 R-21 180 90 New 4.3.1-A6 Living Dining Wall 777 0.069 R-21 270 90 New 4.3.1-A6 Living Dining Slab 481 0.730 None 0 180 New 4.4.7-A1 Living Dining Slab 2,214 0.730 None 0 180 New 4.4.7-A1 Living Dining Roof 545 0.026 R-38 0 0 New 4.2.1-A9 Bedroom 3 2nd Flr Wall 318 0.069 R-21 0 90 New 4.3.1-A6 Bedroom 3 2nd Flr Wall 310 0.069 R-21 90 90 New 4.3.1-A6 Bedroom 3 2nd FIr Wall 228 0.069 R-21 180 90 New 4.3.1-A6 Bedroom 3 2nd Flr Wall 120 0.069 R-21 270 90 New 4.3.1-A6 Bedroom 3 2nd Flr Floor 253T 0.048 R-19 0 180 New 4.4.2-A4 Bedroom 3 2nd Flr FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 12.5 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Living Dining 18 Window 40.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Living Dining 19 Window 40.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Living Dining ' 20 Window 40.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Living Dining 21 Window _ u_ 58.2 0.390 NFRC 0.28 NFRC 90 New - I Dual non Metal Tinted _ _ Living Dining 22 Window" \.48.0 0.390 NFRC 0.28 NFRC )90 New 'e Dual non Metal Tinted,' Living Dining 23 Window 158.2 0.390 NFRC 1 0.28 NFRC 90 New. ;Dual non Metal Tinted_ Living Dining 24 Window 32.0 --,'0.390 NFRC 0.28 NFRC ..ff 90 New ✓, Dual non Metal Tinted 1 ` . Living Dining 25 Window 22.5 10.390 NFRC 0.28 NFRC u 180 New,-?, `° Dual non Metal Tinted F Living Dining 26 Window ,As ;38.5 , 0.390 NFRC t 0.28 NFRC 180 New -'1 Dual non Metal Tinted ; Living Dining); ` 27 Window' + 38.5 0.390 NFRC c---:0.28 NFRC x.-,180 New Dual non Metal Tinted Living Dining k 28 Window 21.0 0.390 NFRC " , 0.28 NFRC ' 180 New Dual non Metal Tinted Living Dining 29 Window 260.0 0.390 NFRC 0.28 FRC 270 New Dual non Metal Tinted Living Dining 30 Window 38.5 0.390 NFRC 0.28 FRC 270 New Dual non Metal Tinted Living Dining 31 Window 40.0 0.390 NFRC 0.28 !NFRC 270 New Dual non Metal Tinted Living Dining 32 Window 27.0 0.390 NFRC 0.28 FRC 270 New Dual non Metal Tinted Living Dining (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC H t Wd Ove hang Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 JBug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76,- .76 .24 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31' Bug Screen 0.76 32 Bug Screen 0.76 Ener Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24T15:32:15 ID: Pae 7 of 9 Reg: 212-NO04975OB-000000000-0000 Registration Date/Time: 2012/09/07 18:26:20 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2012 Electronically Signed at Ca10ERTS.com by Robin Lever (Fedderly & Associates) 9/26/2012 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Cvetas Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9125/2012 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation I Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Roof 427 0.026 R-38 0 0 New 4.2.1-A9 Bedroom 4 2nd Flr Wall 184 0.069 R-21 0 90 New 4.3.1-A6 Bedroom 4 2nd Flr Wall 220 0.069 R-21 180 90 New 4.3.1-A6 Bedroom 4 2nd Flr Wall 168 0.069 R-21 2701 90 New 4.3.1-A6 Bedroom 4 2nd FIr Roof 301 0.026 R-38 0 0 New 4.2.1-A9 Garage Wall 220 0.069 R-21 0 90 New 4.3.1-A6 Garage Wall 2131 0.069 R-21 90 90 New 4.3.1-A6 Garage Wall 2261 0.069 R-21 180 90 New 4.3.1-A6 Garage Wall 901 0.069 R-21 270 90 New 4.3.1-A6 Garage Slab 803 0.730 None 01 180 New 4.4.7-A1 Garage FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 24.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Living Dining 34 Window 10.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Bedroom 3 2nd Flr 35 Window 8.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Bedroom 3 2nd Flr 36 Window 10.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Bedroom 3 2nd Flr 37 Window w .. 8.0 0.390 NFRC 0.28 NFRC 90 New _ Dual non Metal Tinted Bedroom 3 2nd Fir 38 Window' „`8.0 0.390 NFRC . ,% 0.28 fdFRC 190 New f. `• Dual non Metal Tinted,, Bedroom 3 2nd Fir 39 Window `36.01 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted. Bedroom 3 2nd Flr 40 Window 8.0 -'0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted `, Bedroom 4 2nd Flr 41 Window 8.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Bedroom 4 2nd Flr , 42 Window ,q 142.0 y 0.390 NFRC 0.28 NFRC 270 New. ! Dual non Metal Tinted Bedroom 4 2nd Flr 43 Window', t 10.0 0.390 NFRC 0.28 NFRC -_,270 New .._ Dual non Metal Tinted - f. • '. , Bedroom 42nd Fir, 44 Window 144.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Garage 45 Window 1 64.01 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Garage 46 Window 96.0 0.390 NFRC 0.28NFRC 90 New Dual non Metal Tinted Garage 47 Window 10.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Garage 48 Window 10.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Garage (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Overhang Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 IBug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-09-24715:32:15 ID: Page 8 of 9 Reg: 212-NO04975OB-000000000-0000 Registration Date/Time: 2012/09/07 18:26:20 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 9/25/2012 Electronically Signed at CalCERTS.com by Robin Lever (Fedderly & Associates) 9/26/2012 CERTIFICATE OF COMPLIANCE: Residential - (Part 5 of 5) CF -1 R Project Name Cvetas Residence Building Type © Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/25/2012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered Removed Volume Year Built HVAC 1 Bedroom 2 383 3,830 office' 169 1,690 HVAC 2 Master Bedroom 1,102 13,224 HVAC 3 & 4 Living Dining 2,695 37,730 HVAC 5 Bedroom 3 2nd FIr 545 5,450 Bedroom 4 2nd Flr 427 4,270 HVAC 6 Garage 807 8,070 Totals 1 6,1281 01 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 2 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New HVAC 3 & 4.,,.-^ . * 2 Central. Furnace 80%,AFUE Split Air Conditioner;==, 16.5 SEER. Setback New HVAC 5,1 1 r Central Furnace r 80%'AFUE S lit Air Conditioner 1 16.0 SEER Setback New HVAC 6 1 ' 11 Split Heat Pump 8.00 HSPF Split Heat Pump' 14.5 SEER Setback New Nl_ ' HVAC DISTRIBUTION ! _,-r System Name Heating _ �frDuct t. Ducts -TC. CoolingDuct Location R -Value Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 3 & 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 El New HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.01 R1 lNew HVAC 6 Ductless / with Fan Ductless I n/a n/a INew WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status Bradford White W-1-100TI 2 Large Gas All Pipes Ins 85,000 100 0.80 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft C 0 iC as U) ¢ — System Name Pipe Length Pipe Diameter Insul. Thick. aty. HP Plenum Outside Buried EnergyPro 5.1 by EnergySoft User Number., 6712 RunCode: 2012-09-24715:32:15 ID: Page 9 of 9 Reg: 212-NO04975OB-000000000-0000 Registration Date/Time: 2012/09/07 18:26:20 HERS Provider: CalCERTS, Inc CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Cvetas Residence pPAQUE SURFACE DETAILS Building Type m Single Family 0 Addition Alone Date t7 Multi Family O Existing+ Addition/Alteration 1812012012 Surface --Type- Area Roof 427 Wall 184 Wall 220 Wall 1681 Roof 3011 U- Insulation Joint Appendix Factor Cavity I Exterior Frame Interior Frame Azm Tilt I Status 4 Location/Comments 0.026 R-38 0 0 New 4.2.1-A9 Bedroom 4 2nd FIr 0.069 R-21 0 90 New 4.3.1-A6 Bedroom 4 2nd FIr 0.069 R-21 180 90 New 4.3.1 A6 Bedroom 4 2nd FIr 0.069 R-21 270 90 New 4.3.1 A6 Bedroom 4 2nd FIr 0.026 R-38 0 0 New 4.2.1 A9 Garage Wall . 2201 0.069 R-21` 0 90 New 4.3.1 A6 Garage Door 144 1.450 None 0 90 New 4.5.1-A1 Garage Wall 2131 0.069 R-21 90 90 New 4.3.1 A6 Garage T poor_ 64 1.450 None 90 90 New 4.5.1-A1 Garage Wall 2261 0.069 R-21180 90 New 4.3.1-A6 Garage Wall • 90 Slab 803 0.069 R-21 0.730 1 None 270 90 New 4.3.1-A6 0 180 New 4.4.7-A1 PP-- Garage Garage FENESTRATION SURFACE DETAILS ID. Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 24.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Living Dining 34 Window 10.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Bedroom 3 2nd FIr 35 Window 8.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Bedroom 3 2nd FIr 36 • Window 10.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Bedroom 3 2nd FIr 37 Window 8.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Bedroom 3 2nd FIr 38 Window 8.0 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted Bedroom 3 2nd FIr 39 Window 36.0 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Bedroom 3 2nd FIr ,40 Window 8.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Bedroom 4 2nd FIr .'41- Window 8.0 0.390 NFRC 0.28 NFRC 0 New Dual non Metal Tinted Bedroom 4 2nd Fir 42 Window 42.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Bedroom 4 2nd Fir 43 Window 10.0 0.390 NFRC 0.28 NFRC 270 New Dual non Metal Tinted Bedroom 4 2nd FIr 44 Window 45 Window .0 0.390 NFRC 0.28 NFRC 0.390 NFRC 0.28 NFRC 90 New Dual non Metal Tinted 180 New Dual non Metal Tinted Garage Garage 46 window 0.390 NFRC 0.28 NFRC 180 New Dual non Metal Tinted Garage 49 IV, .U t (1) -Factor Type: 116 A =Default We from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC Hat Wd 33 Bug Screen 0.76 Overhana Left Fin Right Fin Len Hat I LExt RExt Dist Len Hat Dist I Len Hat 34 Bug Screen 35 Bug Screen 0.76 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bu Screen 0.76 39 Bug Screen 0.76 40 Bu Screen 0.76 41 Bu Screen 0.76 42 Bu Screen 0.76 43 Bu Scn:en 0.76 94 Bug Screen 0.76 45 Bug Screen 0.76 46 Bu Screen 0.76 Ene Pro 5.1 6 Ene Soft User Number: 6712 RunCode: 2012-08-20T13:26:18 ID: Pae 10 of 40 RECORDING REQUESTED BY: 'tQUITY TITLE - ORANGE COUNTY/INLAND EMPIRE AND WHEN RECORDED MAIL TO: Joseph G. Cvetas and Jennifer L. Cvetas 9351 Gatzshead Drive Huntington Beach, CA 92646 Order No.: OR1155843 Escrow No.: PD -05018 -LH A.P.N.: 777-180-014-7 '—ja tt 0W -j60 t j , - T, AUG 31 2012 SPACE ABOVE THIS LINE IS FOR RECORDER'S USE GRANT DEED THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX IS $495.00 CITY TRANSFER TAX IS $.00 [ X ] computed on full value of property conveyed, or 0 computed on full value less value of liens or encumbrances remaining at time of sale. 0 unincorporated area [ X ] City of La Quinta AND FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, P. Alan Gambill and Joetta L. Gambill, Trustees of the Gambill Revocable Trust dated December 17, 2003 hereby GRANT(S)to Joseph G. Cvetas and Jennifer L. Cvetas, Trustees of The Cvetas Family Trust, UDT, dated April 17, 1997 the following described real property in the County of Riverside, State of California: See Exhibit "A" attached hereto and made a part hereof for complete legal description. AKA: 53351 Via Strada (Vacant Lot#248), La Quinta, CA 92253 Dated: December 19, 2011 STATE OF CAM-QRidt;r COUNTY OF tft(A'nt \. . I SS. On before me N aryPu ic, erson Ily appeared CC who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies) and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s), acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and o cia seal. Signature Sign ur ' fMl- y Z Expiration ate:'� <Z ? , -- Commission G itle�eyabl rust dated December 17, 2003 By: P. Alan G f nbill, Trustee By: Joetta L. Gambill, Trustee 9WQ 12 (This area for official notarial seal) MAIL TAX STATEMENTS TO: Joseph G. Cvetas and Jennifer L. Cvetas (same as above) EXHIBIT "A" PARCEL NO. 1: ORDER NO. OR1155843 LOT 248 (THE "LOT") OF AMENDED TRACT NO. 29894-2 AS SHOWN ON SUBDIVISION MAP (THE "MAP") RECORDED ON DECEMBER 12, 2002, IN BOOK 327, PAGES 56 TO 88, INCLUSIVE, OF MAPS, IN THE OFFICE OF THE RIVERSIDE COUNTY RECORDER. PARCEL NO. 2: NONEXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, EGRESS, DRAINAGE, MAINTENANCE, REPAIRS AND FOR OTHER PURPOSES, ALL AS DESCRIBED IN THE DECLARATION. -END OF LEGAL DESCRIPTION"** 1301 1-502-A (P1) REV. 11 (07-10) PRELIMINARY CHANGE OF OWNERSHIP REPORT To be completed by transferee (buyer) prior to transfer of subject property in accordance with Section 480.03 of the Revenue and Taxation Code. A Preliminary Change of Ownership Report must be filed with each conveyance in the County Recorder's office for the county where the property is located. Please answer all questions in each section, and sign and complete the certification before filing. This particular form may be used in all 58 counties of California. If a document evidencing a change in ownership is presented to the Recorder for recordation without the concurrent filing of the Preliminary Change of Ownership report, the Recorder may charge an additional recording fee of twenty dollars ($20). THIS REPORT IS NOT A PUBLIC DOCUMENT NOTICE: The property which you acquired may be subject to a supplemental assessment in an amount to be determined by the County Assessor. Supplemental assessments are not paid by the title or escrow company at the close cf escrow, and are not included in lender impound accounts You may be responsible for the current or upcoming property taxes even if you do not receive the tax bill. For further information on your supplemental roll obligation, please call the Riverside County Assessor. SELLER/TRANSFEROR: the Gambill Revocable Trust dated December 17, 2003 BUYER/TRANSFEREE: the Cvetas Family Trust dated 4/17/1997 ASSESSOR'S PARCEL NUMBER(S): 777-180-014-7 PROPERTY ADDRESS OR LOCATION: 53351 Via Strada (Vacant Lot#248), La Quinta, CA, 92253 MAIL TAX INFORMATION TO: Name: the Cvetas Family Trust dated 4/17/1997 A. J N jiiv 6To� /.TZA`'/, 9 y Address: , , CA 9 3 Si GAs- �s✓� #6 /'S97 Buyer's Daytime Phone Number: (1''r. - ❑ YesNo THIS PROPERTY IS INTENDED AS MY PRINCIPAL RESIDENCE. If YES, please moicate the u— u, uk—F—vr ��- occupan PART I: TRANSFER INFORMATION Please complete all statements. YES NO ❑ 0 A. This transfer is solely between spouses (addition or removal of a spouse, death of a spouse, divorce settlement, etc. domestic partners currently registered with the California Secretary of State (addition of a partner, 13B. 'C. This transfer is solely between death of a partner, termination settlement, etc.)? This is a transfer between ❑ parent(s) and child(ren) ❑ or from grandparent(s) to grandchild(ren) ❑ I�r ❑ j$ 'D. This transaction is to replace a principal residence by a person 55 years of age or older. ❑ 6 'E. Within the same county? ❑ Yes ❑ No This transaction Isto replace a principal residence by a person who is severely disabled as defined by Revenue and Taxation ❑ F. Code section 69.5. Within the same county. This transaction is only a correction of the name(s) of the person(s) holding title to the property (for example, a name change ❑ G. upon marriage)? Please explain The recorded document creates, terminates, or reconveys a lenders interest In the property. terminate, or reconvey a security interest ❑ H. This transaction is recorded only as a requirement for financing purposes or to create, �} I. (e.g., cosigner) If YES, please explain This recorded document substitutes a trustee of a trust, mortgage, or other similar document. ❑ ❑ `)51 J. ❑ This is a transfer of property: 1. to/from a revocable trust that may be revoked by the transferor and 1s for the benefit of the ❑ ❑ transferor ❑ transferors spouse ❑ registered domestic partner be by the Creator/Grantor who is also a joint tenant, and which names the other joint tenant's ❑ 2. to/from a trust that may revoked as beneficiaries when the Creator/Grantor dies. 3. to/from an irrevocable trust for the benefit of the ❑ Creator/Grantor and/or ❑ Grantors spouse ❑ Grantors/Trustors registered domestic partner ❑ K. 4. to/from an irrevocable trust from which the property reverts to the Creator/Grantor within 12 years. This property is subject to a lease, is the remaining lease term 35 years or more including written options transferee(s) in each and every parcel ❑ ❑ L. This is a transfer between parties in which proportional interests of the transferor(s) and being transferred remain exactly the same after the transfer. is transfer subject to subsidized low income housing requirements with governmentally Imposed restrictions. ❑ M. ❑ 'N. This a This transfer is to the first purchaser of a new building containing an active solar energy system may allow you to retain your previous tax base. If ' If you checked yes to C, D or E, you may qualify for a property tax reassessment exclusion, which to N, you may quality for a property tax new construction exclusion. A claim form must be filed and all requirements met in you checked yes statement order to obtain any of these exclusions. Contact the assessor for claim forms. Please provide any other information that would help the Assessor to understand the nature of the transfer. THIS DOCUMENT IS NOT SUBJECT TO PUBLIC INSPECTION (PcoT) (10-03) (Rev. 10-10) BQE'=o02-A (P1) REV. 11 (07-10) PART 2: OTHER TRANSFER INFORMATION Check and complete as applicable. A Date of transfer if other than recording date B. Type of transfer. Please check appropriate box. Purchase ❑ Foreclosure ❑ Gift ❑ Trade or Exchange ❑Merger, Stock, or Partnership Acquisition ❑ Contract of Sale - Date of Contract ❑ Other: (please explain): [3 Inheritance - Date of Death ❑ Sale/Leaseback ❑ Creation of a Lease 13 Assignment of a Lease ❑ Termination of a Lease Date lease began Original term in years (including written options) Remaining tern in years (including written options) Remaining Term Monthly Payment ❑ Other. Please explain: C. Was only a partial interest in the property transferred? ❑ Yes No If yes, indicate the percentage transferred "o PART 3: PURCHASE PRICE AND TERMS OF SALE Check and complete as applicable. ❑ New Loan ❑ Bank or Savings & Loan ❑ Fixed Rate A. Total Purchase or acquisition price. Do not include closing costs or mortgage Insurance $ yso.o;Coo DOWN PAYMENTS Interest Rate: % Seller Paid Closing Costs: Balloon Payment: $ ❑ Loan Carried by Seller ❑ Assumption of Contractual Assessment' with a remaining balance of:$ 'An assessment used to finance property specific improvements that constitutes a lien against the real property B. The property was purchased e Through real estate broker Broker name. � �' rJ CMAitt.7 Phone number: % " 90 L• J Y existing loan balance) that C. Please explain any special r ms, seller concessions, or financing and any other information (e.g. buyer assumed th would assist the Assessor In the valuation of your property: PART4: PROPERTY INFORMATION Check and complete as applicable. A. TYPE OF PROPERTY TRANSFERRED: ❑ Agricultural ❑ Timeshare ❑ Single-family residence ❑ Co-op/Own-your-own ❑ Manufactured Home ❑ Multiple -family residence (no. of units: ) ❑ Condominium ,M Unimproved lot ❑ Commercial/Industrial ) ❑ Other (Description: i.e. timber, mineral, water rights, etc. B 13 Yes No Personal/business property, or incentives, are included In the purchase price. Examples are furniture, farm equipment, machinery, club memberships, etc. Attach list if available Attach itemized list o/personal property). If yes, enter the value of the personal property included in the purchase price $ C. ❑ Yes W, No A MANUFACTURED HOME INCLUDED IN PURCHASE PRICE If yes, how much of the purchase price is allocated to the manufactured home? $ If no, enter decal number: 13 Yes ❑ No Is the manufactured home subject to local property tax? D. ❑ Yes C'No DOES THE PROPERTY PRODUCE INCOME? If yes, the income from: ❑ Lease/Rent ❑ Contract ❑ Mineral Rights ❑ Other -(please explain): E. THE CONDITION OF PROPERTY AT THE TIME OF SALE WAS: 0- Good ❑ Average ❑ Fair ❑ Poor VCR 1 irve- I ,v.. 1 certify(or declare)undor penalty of perjury under the laws of the state of California that the foregoing and all Information ei including any accompanying statements or document, Is true, correct and complete to the best of my knowledge and belief. This declaration is binding on each and every buyer/transferee. b NAME OF R.T NSFER EILEGAL REPRESENT A VE/CORPO TE OFFIC R (PLEASE PRINT) .�o�VLi" ti J.Z ivrrL.t G. GY.ET/j/ E-MAIL ADDRESS ` C VE T/Q-f S y� s��,AnrA/N�). �� `l The Assessor's office may contact you for additional information regarding (poor) (10-03) (Rev. 10-10) LARRY W. WARD COUNTY OF RIVERSIDE ASSESSOR -COUNTY CLERK -RECORDER DOCUMENTARY TRANSFER TAX AFFIDAVIT WARNING ANY P'-RSON WHO MAKES ANY MATERIAL MISREPRESENTATION OF FACT FOR -1 HE PURPOSE OF AVOIDING ALL OR ANY PART OF THE DOCUMENTARY TRANSFER TAX IS GUILTY OF A MISDEMEANOR UNDER SECTION 5 OF ORDINANCE 516 OF THE COUNTY OF RIVERSIDE AND IS SUBJECT TO PROSECUTION FOR SUCH OFFENSE. Recorder P.O. Box 751 Riverside, CA 92502-0751 (951)486-7000 Website: www.riversideacr.com ASSESSOR'S PARCEL NO. 777480-014-7 I declare that the documentary transfer tax for this Property Address: 53351 Via Strada (Vacant Lot#248), La Quinta, CA 92253 transaction is: $• If this transaction is exempt from Documentary Transfer Tax, the reason must be identified below. I CLAIM THAT THIS TRANSACTION IS EXEMPT FROM DOCUMENTARY TRANSFER TAX BECAUSE. (The Sections listed below are taken from the Revenue and Taxation Code'. Please check one or explain in "Other'.) 1. _ Section 11911. The document is a lease for a term of less than thirty-five (35) years (including options). 2. _ Section 11911. The easement is not perpetual, permanent, or for life. 3. _ Section 11921. The instrument was given to secure a debt. 4. _ Section 11922. The conveyance is to a governmental entity or political subdivision. 5. _ Section 11925. The transfer is between individuals and a legal entity, or between legal entities, and does not change the proportional interests held. 6. Section 11926. The instrument is from a trustor to a beneficiary, in lieu of foreclosure, and no additional consideration was paid. 7. _ Section 11926. The grantee is the foreclosing beneficiary and the consideration paid by the foreclosing beneficiary does not exceed the unpaid debt. 8. _ Section 11927. The conveyance relates to a dissolution of marriage or legal separation. 9. _ Section 11930. The conveyance is an inter vivo gift* or a transfer by death. *Please be aware that information stated on this document may be given to and used by governmental agencies, including the Internal Revenue Service. Also, certain gifts in excess of the annual Federal gift tax exemption may trigger a Federal Gift Tax. In such cases, the Transferor (donor/grantor) may be required to file Form 709 (Federal Gift Tax Return) with the Internal Revenue Service. 10. _ Section 11930. The conveyance is to the grantor's revocable living trust. 11. ,_ Other (Include explanation and authority) CORRE I DECLARE ER 0f TY OF PERJURY THAT THE I�Qi�rC` N TRS AN Executed thi y of fj� 20 at (� City Stat �.c�(/.� Lj 4 EST COAST ESCSOW � STE.�: Signatu i a e t Printed Name of Affiant 72-608 EL PASEO, L PAS �' Address of Affiant /�._ �� i /D �(�Cj�� PALM DESERT, CA 922r� .' Name oVAtatf6�. WMF& 1ant (y 7 Telephone Number of Affiant (including area code) This form is subject to the California Public Records Act (Government Code 6250 et. seg.) For Recorder's Use: Affix PCOR Label Here ACR 521P-AS4EX0 (Rev. 11/2010) RF *- V Page 1 of 1 Denisse Rocha AUG 31 2012 From: Brook Marshall [brook@dc.rr.com] BY; Sent: Tuesday, August 07, 2012 8:18 AM } To: Denisse Rocha; 'Tracy Young' Denisse: I reviewed all the letters for the projects you asked about yesterday and all of the letters seem to be pretty well articulated stating that construction can begin subject to the following comments being addressed prior to the setback observation, etc. Have someone from the City call me to explain what they need if that is not sufficient. Thanks. Brook a 8/22/2012 Denisse Rocha Full Name: Brook Marshall Last Name: Marshall First Name: Brook Job Title: DRC Facilitator Company: Hideaway DRC / Discovery Land Business Address: 41800 Washington Street B105-636 Bermuda Dunes, CA 92203 Mobile: (760) 219-8057 E-mail: brook@dc.rr.com E-mail Display As: brook@dc.rr.com HIDEAWAY OWNERS ASSOCIATION July 5, 2012 Mr. Joseph Cvetas 17941 Pitch Irvine, CA. 92614 RE: Cvetas/Lot 248 at 533.51 Via Strada Final Design Review #2 Dear. M.r. Cvetas. The Hideaway Design Review Committee (DRC) reviewed and approved the revised Final Design Submittal for Lot 248 on Via Strada subject to the following stipulations being addressed prior to the request for Setback Observation at your lot: I . The exterior wall sconces are not specified but are noted to be `'selected by owner". Please provide a cut sheet for review and approval prior to installation in the field. In addition, the maximum wattage per bulb must be consistent with the guideline requirements. 2. Any exterior drapes utilized at the home must be submitted for review and approval prior to installation in the field. 3. All hard scape.materials must be submitted for review and approval. This may be done when field samples are approved for the roof tile and exterior house colors. 4.. All pots must be submitted for approval when chosen and prior to installation. 5. Please add two upright trees (minimum 36" box size) at the following locations to screen the upper level from the house next door. One opposite the utility room doors at the garage and one directly opposite the large window at the stairs. 6. The planter along the driveway must be a minimum 3' clear 1'rom the existing property line wall and sufficient trees must be provided to screen the garage form the adjacent: property. 7. There are three palms and one canopy tree shown as being removed and three palms as being relocated. This must be approved by Gerry Tarsitano along with. the proposed grading within the easement area, S. Gerry Tarsitano reviewed the plans and, had the following comments: a. Relocation of palms to be determined in the field due to existing golf course irrigation. b. Removal. of the existing trees will be allowed: however, the Owner will need to provide a replacement tree which will be used elsewhere on Golf Club property. c. All costs associated with this request will be paid by the Owner and performed under the direction of the Getty Tarsitano's staff. Please contact Brook Marshall at (760) 219-8057 or by email at I with any questions or to schedule Your Pre-Constructi6n Meeting prior to any work starting in the field. As a reminder, the DRC will meet only once in August (the second half of the month the URC will be "dark' to accommodate vacation schedules). SincerelJ,, Hideaway Design Review Committee cc: Lance Fedderly JCveas@south lariiliruLcom Gerry T'arsiiano DRC file 80955 Avenue 52 La QUtnta, CA 922.73 P: 760.393-5210 F: 760 398-5788 L1 R1A T 2 UCJT UIT M E'��GI�� EERrIr��G 78080 Calle Amigo, Suite 102 Lo Quinta, CA 92253 . Date: November 30, 2012 Design by: R.A. JN: 120550 Structural Calculation For Cvetas Residence At 53351 Via Strada Lot#248 Hideaway La Quinta, CA. Type Of Project: Residential NSFR Revision#2 (2-1-13) Telephone: (760) 771-9930 Cell: (760) 771-9998 Fax: (760) 808-9146 Z N0. \ EXP. i 3 � 2-1-13 I RA STRUCTURAL ENGINEERING I'REPAR►?I:) FOR: CVETAS RESIDENCE SHEET: 78080 CALLY AMIGO. SUITF. 102 53351 VIA STRADA LA QUINTA. CA. 92253 LA QUINTA. CA. JOB NO: 120550 BUS: 760-771-99:30 DRAWING TITLE: FAX: 760-771-9998 FOUNDATION PLAN KEV#2 CELL: 760-808-9146 SCALE: DATE: 2/1/13 3'-o• S0. x 3'-6• DEEP FLAG POLE FOOTING r i I -0' L=B' -0• 24• VADE X 16' DEEP GRADE BEAM 20'-0' LONG CENTERED ON S.W. W/ (4)/3 TOP 6: BOTTOM k /3 TIES O B' O.C. — AL BB y 24 L=4•-0. SOJ L-------------- -------- I I I r - I I 10 I I ,1 2 I I I NpJS I � N � 1 ! I I Lam-.-? J5 ------------►----------r � I t v3 NEW 4• CONCRETE SLAB VATH /3 BARS 0'8" O.C. EACH WAY OVER 2 . CLEAN SAND OVER 10 MIL V,SOUEEN VAPOR BARRIER OVER 2• CLEAN SAND OVER 9OX COMPACTED FILL I I I I Hogs 1 2 I I j I I I I I I E 'r - I 1 I O N 1 0. x6 HI BM/{1 602 I �I X—x �I I v w�OD�m o — I 'muss I I C I O�C, Fi vim Om ❑ 6x8 MOR C G/ I L V EN_ S a a x o . D � � -- n11F --------- + n you I I ��+s - n r- 110-111C ------------ o-----------rlt] ,Gr\ (IN --- — — 1►€ I I ------ — m _D �o H� U J yD01 vODA I I� N ----- -O'�� 6x8 MDR 6x6 HDR 6x6 MDR tl x1 DR DP Jim -6 I /-ear�52-6 DROP I = 6 �N 300 PLF — i q c xp: s I e u HDR +a, N"m Lei aux _6x6 HDR _'� �� o0 6.8 HDR B+ A o a II I NSP (16)160'S PER TOP PL SWCE I d I �v I d> A I o Ip IN a 1 d5, --A--------jo—-- ---- a-- --------- — �— I� IA d>E I $vI $ Ia dg I �\ 53I` d9 \ Aos s I I I d I d G z >T/ n n � C7 C T 9 V n T RA STRUCTURAL ENGINEERING 78080 CALLH AMIGO. SUITE 102 LA QUINTA, CA. 92253 BUS: 760-771-9930 FAX: 760-771-9998 CILI.: 760-808-9146 FOR: RAWING TITLE: CVhTAS R► SIDENCE 53351 VIA STRADA LA QUINTA. CA. DETAIL A HRET: NO:120550 REV#2 DATE: 2/1/13 1— 4X4 POST, U.N.O. SEE PLAN 2— SEE TABLE 3— EMBEDMENT IS FROM TOP OF SLAB AT MONO—POUR FOUNDATION SYSTEM 4— OPTIONAL COLD JOINT AT 2—POUR SYSTEMS 5— EMBEDMENT IS FROM COLD JOINT AT 2—POUR SYSTEM .S: SIMPSON "SET—XP" EPDXY—TIE(ICC ESR -2508) =R TO ICC AND MANUFACTURER's SPECS. FOR ALLATION PROCEDURES. SPECIAL INSPECTION IS JIRED, DURING ALL INSTALLATIONS. MIN. CRETE STRENGTH f'c= 2500 psi ADEQUATE SIZE HER REQUIRED WHEN ANCHOR BOLT SIZE IS LLER THAN HOLE ;N HOLDOWN. CONTRACTOR SHALL SPECIFY OVERALL LENGTH OF ANCHOR. MISSING REPLACE W/ ROD EMBEDMENT HOLDOWN STRAP HDU2/HDU4 5/8" 10" HDU2/HDU4 HDU5 HDU5 HDU6/HDU8 HDU6/HDU8 7/8" 12" FIX FOR MISSING HOLDOWN SCALE: NTS 30 RA STRUCTURAL ENGINEERING 78080 CALLS AMIGO. SUITE 102 LA QUINTA. CA. 92253 BUS: 760-771-99:30 PAX: 760-771-9998 CELL:760-808-9146 WING CVITAS RESIDENCE 53351 VIA STRADA LA RUINTA, CA. DETAIL B POST/BEAM CONNECTION SCALE: NTS PLAN 36 EA. SIDE PLAN NO: 120550 EV#2 ATE: 2/1/13 'S USE 2X KING STUD )F BEAM TO POST NAIL 16" O.C. TO POST (3)-16d's TO BEAM _ATE O LATERAL ANALYSIS SECTION 2 LONGITUDINAL ROOF AVERAGE HEIGHT = 20.00 FT TOP PLATE AVERAGE HEIGHT = 15.00 FT 20 FT. MAX ROOF HEIGHT WIND FORCE = 22.97 PSF WIND.LOAD = 22.97 x ( 20.00 - 15.00/2 ) = 287.00 PLF SEISMIC LOAD = 0.145 x ( 30.00x55.00 + 15.00x2x8 + I O.00x2x8) = 297.00 PLF SEISMIC GOVERNS = 297.00 PLF MAX. SHEAR = 297.00 x 41.00 / 2 x 55.00 = 111.00 PLF CHORD FORCE = 297.00 x 41.00 x 41.00 / 8 x 55.00 = 1136.00 LBS USE ''/z" CDX UNBLOCKED WITH 8D'S AT 6", 12" O/C USE (8) 16D'S PER TOP PLATE SPLICE SECTION 3 LONGITUDINAL ROOF AVERAGE HEIGHT = 15.00 FT TOP PLATE AVERAGE HEIGHT = 10.00 FT 15 FT. MAX ROOF HEIGHT WEND FORCE = 21.54 PSF WIND LOAD = 21.54 x ( 15.00 - 10.00/2 ) = 216.00 PLF SEI:SM:IC LOAD = 0.145 x ( 30.0006.00 + 15.00x2x5 + 10.00x4x5) = 382.00 PLF SEISMIC GOVERNS = 382.00 PLF MAX. SHEAR = 382.00 x 22.00 / 2 x 76.00 = 53.00 PLF CHORD FORCE = 382.00 x 22.00 x 22.00 / 8 x 76.00 = 304.00 LBS USE'/z" CDX UNBLOCKED WITH 8D'S AT 6", 12" O/C USE (6) 16D'.S PER TOP PLATE SPLICE SECTION 4 LONGITUDINAL ROOF AVERAGE HEIGHT = 13.00 FT TOP PLATE AVERAGE HEIGHT = 10.00 FT 15 FT. MAX ROOF HEIGHT WIND FORCE = 21.54 PSF WIND LOAD = 21.54 x ( 13.00 - 10.00/2 ) = 173.00 PLF SEISMIC LOAD = 0.145 x ( 30.00x14.00 + 25.00x2x5) = 83.00 PLF WIND GOVERNS = 173.00 PLF MAX. SHEAR = 173.00 x 14.00 / 2 x 14.00 = 87.00 PLF CHORD FORCE = 173.00 x 14.00 x 14.00 / 8 x 14.00 = 305.00 LBS USE''/2" CDX UNBLOCKED WITH 8D'S AT 6", 12" O/C USE (6) 16D'S PER TOP PLATE SPLICE SHEAR WALL DESIGN SW #6 REAR OF BDRM 3 TOTAL LOAD = 184.00 x 28.00/2 = 2576.00 LBS. SHEAR WALL LENGTH = 9.50 FT. SHEAR WALL = 2576.00 / 9.50 = 272.00 PLF USE SHEAR WALL TYPE 1 l WITH 16D'S AT 4" O/C SILL :PLATE NAILING MAX. DRAG = 1365.00 LBS. USE (12) 16D'S PER TOP PLATE SPLICE MAX. UPLIFT = 1936.00 LBS USE SIMPSON (2) CS 16 STRAP EACH END SW #7 FRONT OF BDRM 3 TOTAL LOAD = 184.00 x 16.00/2 = 1472.00 LBS. SHEAR WALL LENGTH = 7.00 FT. SHEAR WALL = 1472.00 / 7.00 = 211.00 PLF USE SHEAR WALL TYPE 10 WITH 16D'S AT 6" O/C SILL PLATE NAILING MAX. DRAG = 565.00 LBS. USE (6) 16D'S PER TOP PLATE SPLICE MAX. UPLIFT = 1740.00 LBS USE SIM:PSON (2) CS16 STRAP EACH END SW #8 RIGHT OF NOOK, KITCHEN AND GARAGES TOTAL LOAD = 658.00 x 24.00/2 = 7896.00 LBS. SHEAR WALL LENGTH = 4.00 + 14.00 + 8.00 + 3.75 = 29.75 FT. SHEAR WALL = 7896.00 / 29.75 = 265.00 PLF REDUCE SHEAR WALL CAPACITY FOR HEIGHT TO WIDTH USE SHEAR WALL TYPE 12 WITH 5/8" x 12" A.B. AT 12" O.0 MAX. DRAG = 1255.00 LBS. USE (12) 16D'S PER TOP PLATE SPLICE MAX. UPLIFT = 2285.00 LBS USE SIMPSON .HDU5 HOLDOWN EACH END SW #9 LEFT OF NOOK, WINE AND GARAGE TOTAL LOAD = 658.00 x 24.00/2 + 297.00 x 41.00/2 = 13985.00 LBS. SHEAR WALL LENGTH = 10.00 + 8.00 + 6.00 = 24.00 FT. SHEAR WALL = 13950.00 / 24.00 = 583.00 PLF USE SHEAR WALL TYPE 13 WITH 5/8" x 12" A.B. AT 8" O.C. MAX. DRAG = 1961.00 LBS. USE (14) 16D'S PER TOP PLATE SPLICE MAX. UPLIFT = 5122.00 LBS USE SIMPSON HDU5 HOLDOWN EACH END S W # 10 LEFT OF LIVING ROOM AND VERANDA TOTAL LOAD =:Z RZ00 x 41.00/2 = 60 97,00 LBS. SHEAR WALL LENGTH = 11.00 + 5 a =16. o FT. SHEAR WALL -60M.00/16. =3 $1. o PLF USE SHEAR WALL TYPE 12 WITH 5/8" x 12" A.B. AT 12" O.0 MAX. DRAG = 2074.00 LBS. USE (16) 16D'S PER TOP PLATE SPLICE MAX. UPLIFT = 5079.00 LBS USE SIMPSON HDU5 HOLDOWN EACH END CLIENT: RA Structural Engineering, SHEET: SUBJECT: JOB NO: DESIGN BY: DATE: 6 h e (k 6A 9 Ok (P 15lePtace L= 5 4 3q' 2.57 J scl L,L : f ZdP2 6zz, g P4 LAISrV- �xg D, F. Pit + 11 P -16 fi = . 2°�°7.P1 x �� _ 6 V=�BSss= 3g p1� � 6 Tit S �Pmf Valve = vcjf a 2 h, lyor Take 23os. .3. y c tic ShPar WaA Tyke V = f `160 Flo( 2_s� S : 38 3 P� -5$1 Phi- z 183 FO /ok Reza PROJECT: 6x8 HDR @ CHIMNEY PAGE: As har„ Dur CLIENT: tot 248'The:Hideaway, CVETAS DESIGN BY: R.A. 9 M JOB NO.: 120550 DATE: 2/1/2013 REVIEW BY: R.A. Wnnrd;Bparn D[3sii5n Base en':NbS.2005'" INPUT DATA & DESIGN SUMMARY Duration Factor, Co Condition L 0.90 MEMBER SIZE 6 x 8 No. 1, Douglas Fir -Larch Occupancy Live Load MEMBER SPAN L = 5 ft ; Poz UNIFORMLY DISTRIBUTED DEAD LOAD WD = 622.5 lbs/ft 1.60 Wind/Earthquake Load 6 W` �-Po, Impact Load UNIFORMLY DISTRIBUTED LIVE LOAD WL = 415 lbs/ft J d 9v t S1 ANALYSIS CONCENTRATED DEAD LOADS PD1 = 0 lbs W0 wseg wt = (0 for no concentrated load) L, = 0 ft 1.96 kips, at 7.5 inch from left end PD2 = 0 lbs L2 = 0 ft DEFLECTION LIMIT OF LIVE LOAD d L = L / 360 Camber => 0.04 inch DEFLECTION LIMIT OF LONG-TERM d Kcr D • L = L / 240 Does member have continuous lateral support by top diaphragm ? (1= yes, 0= no) 1 Yes Code Duration Factor, Co Condition 1 0.90 Dead Load 2 1.00 Occupancy Live Load 3 1.15 Snow Load 4 1.25 Construction Load 5 1.60 Wind/Earthquake Load 6 2.00 Impact Load Choice => 4 Construction Load ANALYSIS 1E= N/A DETERMINE REACTIONS, MOMENT, SHEAR wseg wt = 9 lbs / ft RLeft = 2.62 kips VMax = 1.96 kips, at 7.5 inch from left end DETERMINE SECTION PROPERTIES& ALLOWABLE STRESSES THE BEAM DESIGN IS ADEQUATE. Code Designation 1 Select Structural, Douglas Fir -Larch 2 No. 1, Douglas Fir -Larch 3 No. 2, Douglas Fir -Larch 4 Select Structural, Southern Pine 5 No. 1, Southern Pine 6 No. 2, Southern Pine Choice => 2 RRight = 2.62 kips MMax = 3.27 ft -kips, at 2.50 ft from left end b = 5.50 in Emir, = N/A E= Ex= 1600 ksi Fb = N/A d = 7.50 in FbE = N/A Fb = 1,350 psi F = FbE / Fe = N/A A = 41.3 int 1 = 193 in F„ = 170 psi Fe = 1,688 psi Sx = 51.6 in RB = N/A E' = 1,600 ksi Fv' = 213 psi 1E= N/A CD CM C( Ci CL CF Cv C, Cr 1.25 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 :_CK BENDING AND SHEAR CAPACITIES fb = MMax / Sx = 761 psi < Fb = 1688 psi [Satisfactory] f,'= 1.5 VMax / A = 71 psi < F, [Satisfactory] =CK DEFLECTIONS Id (L. Max) = 0.02 in, at 2.500 ft from left end, < d L = L / 360 (Satisfactory) d (Kcr D + L . Max) = 0.06 in, at 2.500 ft from left end < d Kcr o . L - L / 240 [Satisfactory] Where Kcr = 1.50 , (NDS 3.5.2) (DETERMINE CAMBER AT 1.5 (DEAD + SELF WEIGHT) A (1.5D. Max) = 0.04 in, at 2.500 ft from left end CHECK THE BEAM CAPACITY WITH AXIAL LOAD AXIAL LOAD F = 1 kips THE ALLOWABLE COMPRESSIVE STRESS IS F,' = Fc Co Cp CF = 1414 psi Where Fc = 925 psi Cp = 1.60 CF = 1.00 (Lumber only) Cp = (1+F) / 2c - [(1+F) / 2c)2 - F / c10.5 = Fc* = Fc Co CF = 1480 psi Le = Ke L = 1.0 L = 60 in d = 7.5 in SF =slenderness ratio = 8.0 < FcE = 0.822 E'min / SF = 7449 psi E'min = 580 ksi F = FcE / Fc* = 5.033 C = 0.8 THE ACTUAL COMPRESSIVE STRESS IS fc = F / A = 24 psi < Fc' THE ALLOWABLE FLEXURAL STRESS IS Fe = 2160 psi, [ for Cp = 1.6 ] THE ACTUAL FLEXURAL STRESS IS fb = (M + Fe) / S = 834 psi < F, CHECK COMBINED STRESS [NDS 2005 Sec. 3.9.21 (fc / Fc' )Z + % / [Fb' (1 - fc / FCE)I = 0.388 1 1 F I II [ I I F 11 �— T 0.955 50 [Satisfies NDS 2005 Sec. 3.7.1.41 [Satisfactory] [Satisfactory] < 1 [Satisfactory] Reza PROJECT: Shear Wall #10 Revised PAGE: CLIENT: Sanchez Residence DESIGN BY: R.A. Asgharpour JOB NO.: 12019 DATE: 1/10/2012 REVIEW BY: R.A. INPUT DATA LATERAL FORCE ON DIAPHRAGM: vdla. WIND = 375 plf,for wind 6 Vd a, SEISMIC = 381 plf,for seismic GRAVITY LOADS ON THE ROOF: WDL = 623 plf,for dead load 442 WLL - 415 plf,for live load DIMENSIONS: Lw = 5 ft, h = 12 ft L = 5 ft, hp= 0 ft PANEL GRADE (0 or 1) = 1 <= Sheathing and Single -Floor MINIMUM NOMINAL PANEL THICKNESS = 3/8 in COMMON NAIL SIZE (0=6d, 1=8d, 2=10d) 1 8d SPECIFIC GRAVITY OF FRAMING MEMBERS 0.5 EDGE STUD SECTION 1 pos, b = 4 • in, h = 6 in SPECIES (1 = DFL, 2 = SP) 1 DOUGLAS FIR -LARCH GRADE ( 1, 2, 3, 4, 5, or 6) 4 No. 2 STORY OPTION ( 1=ground level, 2=upper level) 1 ground level shear wall DESIGN SUMMARY BLOCKED 3/8 SHEATHING WITH 8d COMMON NAILS @ 3 in O.C. BOUNDARY & ALL EDGES / 12 in O.C. FIELD, 5/8 in DIA. x 10 in LONG ANCHOR BOLTS @ 28 in O.C. Lw HOLD-DOWN FORCES: TL = 3.30 k , TR = 3.30 k (USE PHD2-SDS3 SIMPSON HOLD-DOWN) DRAG STRUT FORCES: F = 0.00 k EDGE STUD: 1 - 4" x 6" DOUGLAS FIR -LARCH No. 2, CONTINUOUS FULL HEIGHT. SHEAR WALL DEFLECTION: A = 0.66 in ,NALYSIS HECK MAX SHEAR WALL DIMENSION RATIO L / B = 2.4 < 3.5 [Satisfactory] (allowable reduced 2w/h, 2305.3.8.2.2.3) ETERMINE REQUIRED CAPACITY Vb = 381 plf, ( 1 Side Diaphragm Required, the Max. Nail Spacing = 3 in) TUC CUCAD rADArITICC OCD IDr T�klI 7Qf)r d I Panel Grade Common Nail Min. 1 Min. Penetration 'rhickness (in) (in) Blocked Nail Spacing Boundary & All Edges 6 1 4 3 2 Sheathing and Single -Floor 8d 1 1/2 3/8 183 1 267 1 342 442 Note: The Indicated shear numbers nave reaucea oy specmc gravlry Tactor per ICI. note a. VE DRAG STRUT FORCE: F = (L -Lw) MAX( vdla, WIND. Oovma. SEISMIC) = 0.00 k ( S2e = 1 ) (Sec. 1633.2.6) VE MAX SPACING OF 5/8" DIA ANCHOR BOLT (NDS 2005, Tab.t 1 E) 5/8 in DIA. x 10 in LONG ANCHOR BOLTS @ 28 in O.C. rUC unI n nnIAml CnorCC- ECK EDGE STUD CAPACITY Pmax = 4.32 kips, (this value should include upper level DOWNWARD loads if applicable) F� = 1350 psi CD = 1.60 Ca = 0.27 E = 1600 ksi CF = 1.10 Fc = 647 psi A = 19.25 int > fd = 225 psi CO)Satisfactory] / vd,a Wall Seismic Overturning Resisting Safety Net Uplift Holddown (plo at mid -story Ibs) Moments ft -lbs Moments ft -lbs) Factors lbs SIMPSON + +0.75he + = 0.656 in, ASD > 23436 Left 8988 0.9 TL = 3069 G L„sxa Right 8988 0.9 TR = 3069 SEISMIC 381 96 (ASCE 7-05 12.8.6) 5� y0 12 ft G = 9.0E+04 psi Cd = 4 1 = 1 t = 0.221 in e„ = Left 8988 2/3 T = 3302 p`t WIND 375 22500 Aa = 0.02 hsx Right 8988 2/3 TR = 3302 ECK EDGE STUD CAPACITY Pmax = 4.32 kips, (this value should include upper level DOWNWARD loads if applicable) F� = 1350 psi CD = 1.60 Ca = 0.27 E = 1600 ksi CF = 1.10 Fc = 647 psi A = 19.25 int > fd = 225 psi CO)Satisfactory] / (1 L & I R values Snouia lncluoe upper level UrLlr I IOft:eS 11 dppoc;a UIC) .CK SHEAR WALL DEFLECTION: ( IBC Section 2305.3.2) 3 8ynh vnh d. A = A&,./.g +Asw+ ONfd shp+ AC/..1 x/Jfcc .Jlp — + +0.75he + = 0.656 in, ASD > EA L, G L„sxa - 0.514 in alVwrahle. ASD - Where: Vb = 381 plf, , ASD L„, = 5 ft E = 1.7E+06 psi (ASCE 7-05 12.8.6) A = 16.50 in` h = 12 ft G = 9.0E+04 psi Cd = 4 1 = 1 t = 0.221 in e„ = 0.003 in da = 0.15 in (ASCE 7-05 Tab 12.2-1 & Tab 11.5-1) Aa = 0.02 hsx (ASCE 7-05 Tab 12.12-1) ECK EDGE STUD CAPACITY Pmax = 4.32 kips, (this value should include upper level DOWNWARD loads if applicable) F� = 1350 psi CD = 1.60 Ca = 0.27 E = 1600 ksi CF = 1.10 Fc = 647 psi A = 19.25 int > fd = 225 psi CO)Satisfactory] / Anchor Calculations Anchor Selector (Version 4.5.1.0) Job Name: Calculation Summary - ACI 318 Appendix D For Cracked Concrete per ACI 318-08 Anchor Anchor I Steel 18 of Anchors I Embedment Depth (in) Category 5/8" SET -XP IA307 GR. C 1 1 110 1 Concrete Concrete Cracked fc(Psi) y'c.v Normal weight I Yes 12500.0 1.1.00 0 0 iYes Condition Thickness (in) Suppl. Edge Reinforcement B tension and shear 18 No Hole Condition Inspection Temp. Range Dry Concrete Continuous 1 Factored Loads Nue (Ib) Vuax (lb) I Vuay (ib) I Mux ('b -ft) MuY (lb -ft) 2150 10 10 10 10 ex (in) ey (in) I Mod/high seismic Anchor w/ sustained tension Anchor only resists wind/seis loads Apply entire shear @ front row 0 0 iYes lNo I Yes lNo Individual Anchor Tension Loads N uat (Ib) 2150.00 e.Nx(in) e.Ny(in) 0.00 10.00 Individual Anchor Shear Loads V uat (lb) 0.00 e'vx(in) e'vy(in) 0.00 10.00 Tension Strengths Steel (m = 0.80 ) Nya(lb) k4N58(Ib) Nua(lb) N ua /mNsa 13110 110488.00 12150.00 10.2050 Concrete Breakout (kD = 0.75 . (Dws = 0.75 ) N,(lb) mNm(lb) Nua(Ib) Nus/4NCb 8117.57 14566.13 12150.00 10.4709 Adhesive (m = 0.75 . (Dseis = 0.75 ) Ne(Ib) kDNa(lb) Nua(lb) Nua /mNa 7679.25 14319.58 12150.00 10.4977 about: blank Page 1 of 2 t Daterrime : 5/20/2011 11:41:13 AM 5/20/2011 1 Side -Face Blowout does not apply Shear Strengths Steel (4) = 0.75 . tkx eels = 0.71 ) Veq(lb) mVq(lb) Vua(Ib) V ua /mVeq 5584.15 14188.11 10.00 0.0000 Concrete Breakout (case 1) (cD = 0.75 . Oseis = 0.75 ) Vcbx(Ib) 4)V�x(Ib) I Vuax(Ib) I Vuax /mVebx 11798.82 6636.84 10.00 10.0000 VCby(lb) mVcby(lb) VUey(lb) I Vuay /mV�y I Vua /mV. 4334.29 2438.04 10.00 10.0000 10.0000 Concrete Breakout (case 2) does not apply to single anchor layout Concrete Breakout (case 3) ((D = 0.75 , Osais = 0.75 ) cxt edge Vcby(Ib) 4)Vc y(lb) Vuay(lb) Vuey /OV by 3825.21 2151.68 10.00 10.0000 cy, edge V,x(Ib) 4)V.x(Ib) Vuax(Ib) Vuax/mVebx 11622.69 6537.76 0.00 0.0000 cx2 edge V,y(Ib) mVcby(Ib) Vuay(lb) I Vuay /mV -by 23597.64 13273.67 0.00 10.0000 cy2 edge %)x(lb) a'Vcbx0b) Vuax(Ib) Vuax /mVcbx V../(& ctr 11622.69 6537.76 10.00 10.0000 10.0000 Pryout (4) = 0.75. msels = 0.75 ) Vcp(Ib) I NVc,)(Ib) Vuax(Ib) Vuax /mVcP 15358.51 18639,16 10 10.0000 VM(lb) ov po) Vuay(Ib) Vuay /mV.P _ba /mVcp 15358.51 18639.16 10 10.0000 0.0000 Note: Ratios have been divided by 0.5 factor for brittle failure. Interaction check V.Max(0) - 0.2 and T.Max(1) - 1.0 [Sec D.7.11 Interaction check: PASS Use 5/8" diameter A307 GR. C SET -XP anchor(s) with 10 In. embedment aboutNank 5/20/2011 �2 H PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALIMESA CANYON LAKE COACHELLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO LAKE ELSINORE LA QUINTA MENIFEE MORENO VALLEY PALM DESERT PERRIS RANCHO MIRAGE RUBIDOUx CSD SAN JACINTO TEMECULA- WILDOMAR BOARD OF SUPERVISORS: BOB BUSTER DISTRICT 1 JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 MARION ASHLEY DISTRICT 5 • RIVERSIDE COUNTY F` FRSDEPARTMENT IN COOPERATION V ITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 92211-4131 . Phone (760) 863-8886 • Fax (760) 863-7072 www.rvcfire.org July 9, 2012 Dave Williams 81-595 Rancho Santa Dr. La Quinta, CA Re: Residential Fire Sprinkler Plan Review LQ -12 -RS -043 Cvetas Residence 53-351 Via Strada The Hideaway La Quinta, CA The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department Planning & Engineering personnel and are approved with the following conditions: A minimum of three spare fire sprinklers of each type and temperature rating along with a sprinkler wrench should be located in a spare head cabinet at the system riser or other approved location. Permanently marked identification signs shall be attached to all control valves. The completed Contractor's Material and Test Certificate for Aboveground Piping shall be provided to the fire inspector prior to a final inspection. A typical certificate is shown in Figure 10.10.1 NFPA13. A warning sign, with minimum % inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system for this home supplies fire sprinklers that reiquire certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protections specialist. DO NOT remove this sign. The following inspections/tests are required to be witnessed by the Fire Department Planning Division staff: (a) Fire Riser Flush: Prior to connection of above ground sprinkler system a flush shall be witnessed. (b) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. (c) Final inspection. The Fire Department job card, approved plans and conditions letter must be at the job site or NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection date. L� All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection. Sincerely, Jason Stubble Fire Safety Specialist