Loading...
04-7842 (SFD)D JAN 1.0 2005 U CITY OF I.A FINANCE D BUILDING & SAFETY DEPARTMENT P.O. Box 1504 (760) 777-7012 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA•, CALIFORNIA 92253 INSPECTION. REQUESTS (760) 777-7153 BUILDING PERMIT Application Number %55ffVIA -07842 Date 12/29/04 -Property. Address . . . . . TERRA NOVA_ APN: 604-032-999-3-----305212- Application description . . . DWELLING - SINGLE FAMILY DETACHED Property Zoning . . . . . LOW DENSITY RESIDENTIAL Application valuation 155524 Owner Contractor --------------------------------- --------------------------------- LENNAR HOMES -OF CALIFORNIA LENNAR HOMES OF CALIFORNIA INC 78401 HIGHWAY 111, STE C 78401 HIGHWAY 111, SUITE C LA QUINTA, CA LA QUINTA, CA 92.253 LA QUINTA, CA 92253 WCC: AON RIS{ SRVC WC: MWC11114500 11/01/05 CSLB: 728102 09/30/06 CCC: B 'i .. 1. � � I P.O. Box 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT Application Number: 0 q — 'I X y f - Applicant: Applicant's Mailing Address: VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: l -10-Or or tng(neer's Address: tic. No. J?- UFA BUILUINU PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under malty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals �C e, and my Licens�f0 qp force and effect. nse Class 1► / �icense No._� U /Date Lb ractor l�$�OVWVNpn.RU",LDER'DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the. owner -builder will have the burden of proving that he or she did�not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.)' U 1 am exempt under Sec. , B.& P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensafion, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ���PPI ha and will m intain workers' compensation insurance, as q iced b aectjimn the Labor Code, for the -performance of the work for which this permit is PP iss d. yrkers' compensation i nce e a d r) f�ejL, �*311` b olicy Numbei _ I certat, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shad forthwith comply with those provisions. -LD WARNING: FAILURE -TO SECURE WORKERS^t_-41PENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN. EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is. made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct I agree to comply with all city and county ordinances and state laws relating to building construction, and (here by authorize representatives of this cou ter upon the above-mentioned property for inspection purposes. i bate - (Applicant or Agent): ---`------------------------------------------------------------------------- Application'Number . . . . . 04-00007842 ------------'=--------------------------------------------------------------- Structure Information Construction Type . . . . . TYPE V - NON RATED Per Occupancy Type . . . . . . DWELLG/LODGING/LONG <=10 Extension Flood Zone . . . . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC 2385.00 FIRE SPRINKLERS NO ELEC GARAGE SQ FTG 717.00 717.00 ---------------------------------------------------------------------------- PATIO SQ FTG 488.00 ELEC NUMBER OF UNITS 1.00 ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 2385.00 Permit . . . . . . BUILDING PERMIT Additional Additional desc Permit Fee . . . . 835.50 Plan Check Fee 543.08 Issue Date . . . . Valuation . . . . 155524 Qty Unit Charge Per Extension BASE FEE 639.50 56.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG 100,001-500,000 196.00 Permit . . . . . . MECHANICAL Additional desc Extension Permit Fee . . . 65.50 Plan Check Fee 16.38 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension FIXTURE BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU' 9.00 4.00 6.5000 EA MECH VENT FAN 26.00 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 Permit . . . . . Additional desc . . Permit Fee . . . . Issue Date . . . . ELEC-NEW RESIDENTIAL 112.82 Plan Check Fee . . 28.21 Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 2385.00 .0350 ELEC NEW RES - 1 OR 2 F_kMILY 83.48 717.00 ---------------------------------------------------------------------------- .0200 ELEC GARAGE OR NON-RESIDENTIAL 14.34 Permit . . . . . . PLUMBING Additional desc . . Permit Fee . . . . 171.00 Plan Check Fee 42.75 Issue Date Valuation . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 17.00 6.0000 EA PLB FIXTURE 102.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 6.00 .7500 EA PLB GAS PIPE >=5 4.50 ---------------------------------------------------------------------------- Application'Number . . . . . 04-00007842 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING Qty Unit Charge Per Extension 1.00 15.0000 ---------------------------------------------------------------------------- EA PLB GAS METER 15.00 Permit . . . . . GRADING PERMIT Additional desc Permit Fee . . . . 15.00 Plan Check :gee .00 Issue Date ... . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SFD - LOT 3, PLAN 1X, 2385 SF. PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTER: -RES 97.00 ENERGY REVIEW FEE 54.31 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK F:: -]E .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 15.55 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged ----------------- Paid Credited Due Permit Fee Total ---------- 1199.82 ------------------------------ .00 D0 1199.82 Plan Check Total 630.42 .00 D0 630.42 . Other Fee Total 2108.86 .00 D0 2108.86 Grand Total 3939.10 .00 D0 3939.10 Certificate of Insulation Your home has been insulated with John Mansville Fiberglas: insulation products, which are designed for today's safety standards and tomorrow's energy requirements. . Fiberglass is inorganic and therefore permanently noncombustible, so it does not have to be treated with Tire -retardant chemicals that will likely lose their effectiveness over time. It has not been treated with chemicals that can corrode wiring or metal. Fiberglass will not absorb moisture nor will it settle over time as may other insulation materials. This also certifies that insulation have been professionally installed in this home to provide the following thermal performance. Lennar Homes Job Name: La Quints Del Oro Tract: 30521 Piano 1 XR Phase: 8 Lot No: Job Address: SFR=`44-666 Via Tema Nova; L -a Quinta; CAS Ceiling Area: R-30 blown and batt insulation Garage Ceiling: Non -Access: With Living Above 3 Sloping Areas Exterior Walls R-43 batt insulation Overhangs: With Living Above Between Floors: Interior Walls: Access Attic: Subcontractor ...0 J Insulation, Inc. 72-227 Adelaid St, Thousand Palms, CA 82276 `r :JN_ % 32 Mike Dickerson, General Manager - Palm Springs Division R -means resistance to heat flow, The higher the R -value, the greater the insulating power. Ask your builder for the fact sheet on R -values. Keep this certificate with your other valued papers. If you ever sell this home, this certificate should be passed on to the buyer. CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page 1 cf 'n CF -4R LA QUINTA DEL ORO PH- 8 Project Title 44555'`V_ia--ra.Nova, La Quinta, CA 92253 Project Address Nacho Castenada 760-578-6968 Buildel CAplar Henson (CCN #CC2004076) 76�ep1 (�e7022 HERS Rater � � Telephone �iYr�� 6-14-05 Certifying Signature Firm- BCI Testing Street Address: PO Box 50575 Copies to: Builder, HERS Provider Date 6-14-05 Date LENNAR Builder Name Plan 1XR (pg. I of 1) PlaNumber �iroup 5 Sample Group Number 3 (ph 8) Sample House Number HERS Provider: CALCERTS City/State/Zip: Phoenix, AZ 85076 HERS RATER COMPLIANCE STATEMENT The house was: ❑ Tested Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. ❑ The installer has provided a copy of CF -6R (Installation Certificate. ❑ Distribution system is fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts) ❑ Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. ❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CFXDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM If fan flow is calculated as 400cfin/ton x number of tons enter calculated value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) = Check Box for Pass or Fail (Pass=6% or less) ❑ THERMOSTATIC EXPANSION VALVE (TXV) ❑ ❑ Pass Fail ❑ Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection ❑ ❑ Yes is a pass Pass Fail ❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT 1. ❑ Yes ❑ No ACCA Manual D Design requirements have been met (rater has verified that actual installation matches values in CF -1R and design on plan. 2. ❑ Yes ❑ No TXV is installed or Fan flow has been verified. If no TXV, verified fan flow matches design from CF -1R. Measured Fan Flow = ❑ ❑ Yes for both I and 2 is a Pass Pass Fail Compliance Forms August 2001 A-16