Loading...
04-6578 (AR)Tldf 4 4 4" P.O. Box 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING PERMIT Application Number . . Property Address . . . APN: Application description Property Zoning . . Application valuation . BUILDING & SAFETY DEPARTMENT (760),777-7012 FAX (760) 777-7011 INSPECTION REQUESTS (760) 777-7153 . . 04-00006578 . . . 80570 VIA TERRACI: 772-250-999-109 - . . . ADDITION - RESIDE. LOW DENSITY RESID . . . 5400 Date 11/12/04 -5-7 AL CI'T'Y CF 1A OUPTA Owner Contractor frIWAcI6k DEP °. ------------------------ MILLER KEN & SUE ------------------------ OSMOND CONSTRUCTION COMPANY 80570 VIA TERRACINA 49610 DATE PALM DR LA QUINTA CA 92253 LA QUINTA CA 92253 (760) 777-9931 WCC: STATE FUND WC: 170573704 02/01/05 CSLB: 512213 06/30/05 CCC: B ------ Structure Information 80 SQ. FT. ADD UNDER EXISTING ROOF. ----- Construction Type . ... . . TYPE V - NON RATED. Occupancy Type . . . . . . DWELLG/LODGING/CONG <=13 Flood Zone . . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC # BEDROOMS 1.00 FLOOD ZONE NO FIRST FLOOR SQ FTG 80.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc Permit Fee 81.00 Plan Check Fee 52.65 Issue Date Valuation . . . . 5400 Qty Unit Charge Per Extension BASE FEE 45.00 4.00 9.0000 THOU BLDG 2,001-25,000 36.00 -------------------------------------------------- Permit . . . . . . -------------------------- ELECT - ADD/ALT/REM Additional desc Permit Fee . . . . 17.80 Plan Check Fee 4.45 Issue Date Valuation 0 Qty Unit Charge Per Extension BASE FEE 15.00 80.00 .0350 ---------------------------------------------------------------------------- ELEC NEW RES - 1 OR 2 FAMILY 2.80 Permit . . . . . . MECHANICAL Additional desc Permit Fee . . . . 24.00 Plan Check Fee 6.00 Issue Date . . . . Valuation . . . . 0 P.O. Box 1504• /i • w VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011��G� LA QUINTA, CALIFORNIA 92253 4 4aINSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: Applicant: Applicant's Mailing Address: Date: Architect or Engineer: Architect or Engineer's Address: Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is�mfull force and effect. r0 -cense Clas 9 "p f / I C OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or.that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is Myrworkers' cofnpensatiop.insurance-camer aadpolicy number are: I certify that, in the performance ofRhe work'%r which -t is permit is issued, I shall not employ any person In any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec..3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. %d Application Number . . . . . 04-00006578 Page 2 Date 11/12/04 Qty. Unit Charge Per Extension BASE FEE 15.00' 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 ---------------------------------------------------------------------------- Special Notes and Comments 80 sq.ft. add. under existing roof this permit does not include pool,spa block walls or driveway approach. 11/12/04 6: 45:15 AM jjohnson ----------------------------------------------------------------------------- Other Fees . . . . . . . . . ENERGY REVIEW FEE . 5.27 STRONG MOTION (SMI) - RES .54 Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total Charged Paid 122.80 .00 63.10 .00 5.81 .00 191.71 .00 Credited Due ..00 122.80 .00 63.10 .00 5.81 .00 191.71 Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITICATION AMOUNT: COMMAND. AMOUNT: nATF., RECEIPT, CHECK 8- INITIAIA- CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Residence is at the Hideaway, Date: December 8, 2004 Owner's Name: Ken & Sue Miller Phone Na Project Address: 80-570 Via Terracing La Quinta, CA Project Description: Small addition to existing house APN: 772-250-99-109 Tract #: Lot #'s: Type of Development: Residential XX! Commercial Industrial Total Square Feet of Building Area: 80 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct ztd makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: December 8, 2004 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code 65995 80 $ 0.00 $ 0.00 Building Permit Application Completed: Yes/No Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement By: Carey M. Carlson, Asst. Supt., Business Services Note: Any addition to existing house that is 500 sq. ft. or less is exempt form developer fees. Certificate issued by: Elvira Mattson, Office Technician Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this Distr.ct provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day peleod to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other apliicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on :he date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been iss aed for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. h14'..: In. nca;devfs4s;certif iciate at corry?liance corm tables k) USE doc 1/16/03 T `QI .v, L-111 ..1 1+ I - MOUNTAIN VIEW COUNTRY CLUB at La Qulivw C/0 THE MONARCH GROUP P.O. BOX 13710 PALM DESEKT, CA 92255 (760) 776-5100 May 18, 2004 Mr. Ken Millar 3950 Edens Edge Drive Lake Oswego, OR 97034 Re: Mountain Vlewr Country Club HOA 80-570 V&a Terracina Dear Mr. Miller; .f jvti '91 The Architectural/Landscape Committee of the Mountain View Country Club Homeowners' Association have revlewed the plans for your Improvements. The cnmmltiaate Is pleased to inform you that It has approved your piens under the following conditions: Enclosing master bedroom patio is conditional upsan approval froth the City of La Quanta, I 4 i anftoPing Is approved as long as the contractor uses the preclse grading plan In order to properly balance the lot and rnalntin dra!mge. If there are any questions please contact me at (760) 776-5100 ext. 324. 5ixerety, FOR THE BOARD OF DIRECTORS M�O+UNTAIN VIEW COUNTRY CLUB Grace VOMWgen, SEAM Association Manager CC: Board of Dire=rs Urft Fila RECEIVED FEB 0 8 2005 DEVELOPMENT SERVICES DEPT. SPECIAL INSPECTION DAILY REPORT TANDY'S INSPECTION INC. PO BOX 13766 PALM DESERT, CA 92255 OFFICE/FAX 909.769.9717 PAGER 760.776.3339 OF WORK INSPECTED SAMPLE INFORMATION SUPPLIER TYPE OF INSPECTION PERFORMED DRTE el;�b SAMPLE SLUMP TIME IN MIXER TEMP - I (c P ICAL ADDRESS PERMIT NUMBER - �� � L�tJ rl� © - 5:1 C3 JOB NAMEOF ' STRUCTURE SL%vz- ARCHITECT ENGINEER GENERAL CONTRACTOR SUBCONTRACTOR b CERTIFYING AGENCY AND CERTIFICATION NUMBER OF WORK INSPECTED 1 HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY 1 HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BURRING LAWS. CC: I ORS SIGNATURE INSPECTORS CERTIFICAT04 AGENCY AND NUMBER SAMPLE INFORMATION SUPPLIER TICKET NUMBER MIX NUMBER SAMPLED AIR TEMP SAMPLE SLUMP TIME IN MIXER TEMP LOCATION WELDING INFORMATION PROCESS WELDERS NAME CERTIFYING AGENCY AND CERTIFICATION NUMBER 1 HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY 1 HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BURRING LAWS. CC: I ORS SIGNATURE INSPECTORS CERTIFICAT04 AGENCY AND NUMBER ' TITLE 24 REPORT V CWtOFLA QUITit a 24 Report for: BUILDSAFEiIf p `*, AOVEiller Residence FORS UCTI570 Via Terracina oa lev La Quinta, CA Project Designer: Report Prepared By: Joan D. Hacker Insu-form, Inc. 68-255 Corta Road Cathedral City, CA 92234 (760) 324-2046 Job Number: I Date: ` 9/27/2004 The EnergyPro com ter program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number: User Number: 2655 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Checklist 6 Form C -2R Computer Method Summary 8 HVAC System Heating and Cooling Loads Summary 15 Room Load Summary 16 EnergyPro 3.1 By EnergySoft Job Number: User Number: 2655 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R hiller Existing 9/26/2004 Froject Title Date 80-570 Via Terracina La Quinta Project Address Building Pernit # Insu-form Inc. (760) 324-2046 Plan Check t Date .Documentation Author Telephone Computer Performance 15 Field Check Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency.Use Only GENERAL INFORMATION Total Conditioned Floor Area: 2,777 ft2 Average Ceiling Height: 8.0 ft Total Conditioned Slab Area: 2,777 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family 0 Existing Plus Addition Front Orientation: (South) 180 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Const. Component Frame Assembly Location/Comments Tvoe Type U -Value (attic, garage, typical, etc. Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulatior R-19 Wall (W.19.24.16) Wood 0.065 Exterior Wall R-38 Roof (R.38.2xl4.16) Wood 0.028 Exterior Roof Default Wall 1992 -Present Wood 0.088 Exterior Wall Solid Wood Door None 0.387 Exterior Door Default Roof 1978 to Present Wood 0.047 Exterior Roof FENESTRATION Shading Deices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front (South) 56.0 0.85 0.70 Bug Screen ❑ 0 ❑ 0 Right (East) 23.7 0.72 0.73 Bug Screen ❑ 0 ❑ 0 Left (West) 4.0 0.72 0.73 Bug Screen ❑ X❑ ❑ 0 Left (West) 30.0 0.87 0.70 Bug Screen ❑ 0 ❑ 0 Rear (North) 128.0 0.85 0.70 Bug Screen x❑ ❑ ❑ 0 Rear (North) 3.0 0.72 0.73 Bug Screen ❑ 0 ❑ 0 Rear (North) 25.0 0.87 0.70 Bug Screen ❑ x❑ ❑ x❑ ❑ ❑ ❑ ❑ El El 0 ❑ ❑ ❑ ❑ El 1:1 ❑❑ El El El Run Initiation Time: 09/26/04 21:35:14 Run Code: 1096259714 Ener Pro 3.1 By Ener Soft User Number: 2655 Job Number: Pa e:3 of 16 .Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Miller Existing 9/23/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heading Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location/ pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments rpntrhl Furnarp 78%AFUE Flirts in Attic 42 Setback Existing Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 10.0 SEER Ducts in Attic 42 Setback Existing WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or RecoveryStandby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. oCnenoLeQ COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: RAPPY ^(rO1Z. Name: Joan D. Hacker Title/Firm: K^Yf?AvP A'55 Title/Firm: Insu-form,lnc. Address: Z.6S /V. EC. CZ,le"LO VF t%—e�i3 Address: 68-255 Corta Road ~ 56F41��. CA, 4'746 Z Cathedral City CA 92234 Telephone: 'TGD— 327— Ofd ?j S Telephone: (760) 324-2046 Lic. #: C 7-4-er& Z (signature) (date) (signure) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature/stamp) (date) Run Initiation Time: 09/26/04 21.35.14 Run Code* 1096259714 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: PageA of 16 Certificate of Compliance: Residential (Addendum) CF -1 R a, Miller Existing 9/26/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies oases on the aoequacy oT the special justitication ana aocumentation suomitteo. I Plan Field The DHW Svstem "Standard Gas 50 qal or Less" Energv Factor = 0.530. An EF below 0.58 reauires an R-12 External Blanket. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF-6R.plan Field Run Initiation Time: 09/26/04 21:35:14 Run Code: 1096259714 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:5 of 16 Mandatory Measures Checklist: Residential (Page 1 o= 2) � � MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures.regardless of the compliance approach usad. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this: checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ❑X -§150(a): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturer's labeled R -Value. *§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does X ❑ not apply to exterior mass walls). ❑ ' § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ®§116717: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑§150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑X §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control .2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. a§150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. a§ 150(i): Setback thermostat on all applicable heating and/or cooling systems. n§1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, 'non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:6 of 16. Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications fo the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A If not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) '§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts Installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. F IA -11 §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures © §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 2655 Job Number: Page:7 of 16 Computer Method Summary (Part 1 of 3) C -2R �QjllPr Fxistina — 9I2619on Project Title Date _8 0, 57_aserxacina—La_Quinta Project Address Building Pei mit # Ansu form, Inc. (760) 324-2046 Plan CheckMate Documentation Author Telephone Comb er_P_el'folmance _.. 15 Field ChecWDate Source Energy Use (kBtu/sf-yr) Standard Design Proposed Design Compliance Margin Existing+Addition Budget Adjustment Space Heating 1.70 2.36 -0.66 Ratio F: 2655 / 2777 = 0.956 Space Cooling 30.98 47.80 -16.82 Budget Adj: 0.956 X ( 66.79 - 48.03) = 17.94 Domestic Hot Water 10.26 10.17 0.09 The budget shown to the left has been increased using this Budget used upon Existing building Totals 17.94 + 42.95 = 60.89 60.34 0.55 information shown on the C -2R which follows this form. shown on t Perr_ent hatter than Standard: 0.9% Total Conditioned Floor Area: 2,777 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Type: Single Fam Detached Building Front Orientation: (South) 180 deg Total Fenestration Area: 9.7% Number of Dwelling Units: 1.00 Total Conditioned Volume: 22,216 ft' Number of Stories: 1 Total Conditioned Slab Area: 2,777 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume_ _Units Zone Type _ Type — Hgt. Area .Existing 2,777 X22M—1..0A_ Conditioned— wetback_— ___2 _n1a Solar OPAQUE SURFACES Act. Gains Tvpe Area U -Fac. Azm. Tilt Y / N Form 3 Reference Location / Comments Computer Method Summary (Part 2 of 3) C -2R Miller Existing 9/26/2004 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt `Location/ Comments _L Window�ronr (S_outW _5.6_0_ 0.850- 0_Z0_ 180 -9.0 Doubte_W-Uncoated-DQfault_ -Addition 2 Window Right East 15.7 0.720 0.73 90 90 Double Mtl Uncoated Default Addition 3 Window Left West 4.0 0.720 0.73 270 90 Double Mtl Uncoated Default Existin 4 Window Left (West)_ 4.0 0.870 0.70 270 90 Double Mtl Uncoated Default Existin 5 Window Left West 24.0 0.870 0.70 270 90 Double Mtl Uncoated Default Existing 6 Window Left (West) 2.0 0.870 0.70 270 90 Double Mtl Uncoated Default Existing 7 Window Rear (North) 128.0 0.850 0.70 0 90 Double Mtl Uncoated Default Existin 8 Window Rear (North) 3.0 0.720 0.73 0 90 Double Mtl Uncoated Default Existing 6 Window Rear (North) 25:0 0,870 O.70 0 90 Double Mtl Uncoated Default Existing _-0. Window Rigg (East)_ 3.0 x,720 0 73 90 90 Double Mtl Uncoated Default Existing 11 Window Right East_ 5.0 0.720 0.73 90 90 Double Mtl Uncoated Default Existin INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 )w Overhang Wd. Len. Hgt. LEA REA 8.0 8.0 8.0 0.1 8.0 8.0 Left Fin Dist. Len. Fgt. Right Fin Dist. Len. Hgt. Run Initiation Time: 09/26104 21.35.14 Run Code: 1096259714 EnergyPro 3.1 By EnergySoft User Number. 2655 Job Number: Page:9 of 16 Computer Method Summary Minimum (Part 3 of 3) C-2R Miller Existing Efficiency 9/26/2004 Project Title Location / Date THERMAL MASS FOR HIGH MASS DESIGN etc.) R -Value Type Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R-Val. Comments Existing PERIMETER LOSSES F2 Insulation Type Length Factor R-Val. Depth Location / Comments Pipe Slab Perimeter 15 0.76 0.0 0 Addition Slab-Bewteter 90 O.713 _0..0 0 Existing Hydronic Piping Pipe Insul: HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 78%AFLIE Ducts in Attic 4.2 Setback Existing Pipe Hydronic Piping Pipe Insul: System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location I heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 10.0 SEE Ducts in Attic - 4,.2_ Setback Existing WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insula Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (°/a) Ext. Standard Gas 50 gal or Less Small Gas Standard 1 40,000 50 0.53 n/a 12 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. I EnergyPro 3.1 By EnergySoftUser Number: 2655 Job Number: Paae:10 of 16 1 Computer Method Summary (Addendiam) C -2R Miller Existing 9/26/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. I Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 External Bla-iket. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a forra CF -6R. plan Field Run Initiation Time: 09/26/04 21:35:14 Run Code: 1096259714 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 11 of 16 Computer Method Summary (Part 1 of 3) C -2R _MilleFxiStiaa 9MI2Q04 Project Title Date _8.0-.570-/1asecr_aci 1a—Lasa into Project Address Building Permit # -inti-form Inc_ (760) 324-2046 Documentation Author Telephone Plancheck/7ate 15 Field Check Date cgUfer�erformance Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.84 3.88 -1.04 Space Cooling 34.46 52.28 -17.82 Domestic Hot water 10.73 10.64 0.10 Totals 48.03 66.79 -18.77 than Standard: Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: BUILDING ZONE INFORMATION Zone Name 2,655 ft2 Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Single Fam Detached . (South) 180 deg Total Fenestration Area: 9.5010 1.00 Total Conditioned Volume: 21,240 ft 3 1 Total Conditioned Slab Area: 29'655 ft 2 # of Floor Area Volume Units Zone Type .Existing? 655 —21240 -J-G0- G.ondifione.d- Thermostat Typa —Setback— Vent Vent Hgt. Area 2 _n/a Solar OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y / N Form 3 Reference Location / Comments Computer Method Summary (Part 2 of 3) C -2R Miller Existing 9/26/2004 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt comments -1. yindo)nr Front. (,8_autb.) _56._0 0_850 010_ 180_ _9.0. DQublelVltLUncoaiesLDefault_ Existing 2 Window Leftest 4.0 0.720 0.73 270 90 Double Mtl Uncoated Default Existin 3 Window Left est_ 4.0 0.870 0.70 270 90 Double Mtl Uncoated Default Existing 4 Window Left (West) 24.0 0.870 0.70 270 90 Double Mtl Uncoated Default Existing 5 Window Left (West) 2.0 0.870 0.70 270 90 Double Mtl Uncoated Default Existing 6 Window Rear (North), 128.0 0.850 0.70 0 90 Double Mtl Uncoated Default Existing 7 Window Rear (North) 3.0 0,720 0.73 0 90 Double Mtl Uncoated Default Existing 8 Window Rear North 25.0 0.870 0.70 0 90 Double Mtl Uncoated Default Existing 5 Window Right (East)_ 5.0 0.720 0.73 90 90 Double Mtl Uncoated Default Existing INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hg-. Dist. Len. Hgt. 1 Bug Screen 0.76 8.0 7.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 8.0 8.0 8. 0,_1 8.0 _8.0 7 'Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 Run Initiation Time: 09126104 21.35.14 Run Code: 1096259714 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paoe:13 of 16 Comauter Method Summary (Part 3 of 3) C -2R Miller Existing 9/26/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location I Comments Slab Perimeter 210 0.76 0.0 __—O Existin HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location. / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comme-its Central Furnace 78%AFUE Ducts in Attic 4.2 Setback Existin Insul. Pipe Hydronic Piping Pipe System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Air Conditioner 10.0 SEER Ducts in Attic 4.2 Setback Existing WATER HEATING SYSTEMS Rated' Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. Standard Gas 50 gal or Less Small Gas Standard 1 40 000 50 0.53 n/a 12 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 09/26/04 21:35:14 Run Code: 1096259714 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 14 of 16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Miller Existing 9/26/2004 SYSTEM NAME FLOOR AREA Existing 2,777 Number -of Systems 1 Heating System Output per System 89,000 Total Output (Btuh) 89,000 Output (Btuh/sgft) 32.0 Cooling System Output per System 58,000 Total Output (Btuh) 58,000 Total Output (Tons) 4.8 Total Output (Btuh/sgft) 20.9 Total Output (sgftrron) 574.6 Air System CFM per System 1,175 Airflow (cfm) 1,175 Airflow (cfm/sgft) 0.42 Airflow (cfmrron) 243.1 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions 26,0 of 68.3 of Outside Air 0 0 cfm Supply Fan 1175 cfm 68.3 of 111.0 177.4 of �0 Outside Air 0 cfm 79.8/58.9 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM ISensiblel Laten: 1, CFM I Sensible 1,285 46,283 5,:68 592 42,683 0 2,314 2,134 0 0 0 0 0 0 0 0 0 2,314 2,134 50,912 5, 368 46,951 Existing 46,945 0 89,000 Total Adjusted System Output 46,945 0 89,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am RICS (Airstream Tei 68.3 of . 139.0 of Heating Coil �% Return Air Ducts `{ 79.8 / 58.9 of 79.8 / 58.8 of 42.6 / 40.9 of Supply Fan Cooling Coil 1175 cfm h Return Air Ducts �1 Supply Air Ducts 137.3 of ROOMS 70.0 of Suppy Air Ducts 44.4 / 41.8 of 28.9''. R. H. ROOMS 78.0 / 58.2 of I EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 15 of 16 ROOM LEAD SUMMARY PROJECT NAME Miller Existing DATE 9/26/2004 SYSTEM NAME Existing FLOOR AREA 2,777 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM I SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Addition Addition 1 152 5,462 57 152 5,462 57 60 4,357 Existing Existing 1 1,133 40,821 5,311 1,133 40,821 5,311 531 38,326 PAGE TOTAL TOTAL 1 1,285 46,283 5,368 592 42,683 1 1,285 46,283 5,368][592 42,683 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 16 of 16