10-0616 (AR)P.O. BOX 1504 4
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
T-i4t,4 4 Q"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: .9/17/10
Application Number: ,10-00000616 Owner:
Property Address: 804-95 VIA--TALAVERA DALE WEAVER
APN: 777-270-031- - - 80-495 VIA TALAVERA
Application description: ADDITION - RESIDENTIAL LA QUINTA, CA 92253
Property Zoning: LOW DENSITY RESIDENTIAL n O t
Application valuation: 20000
Contractor: I 4 .W ' !
Applicant: - Architect or Engineer: Owner
SES 1 r 2u17
CITY OF LA QUINTA
----------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION • - WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with , I hereby affirm under penalty of perjury one of the following declarations:
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.- _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
License Class: License No.: for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
_ issued.
Date: - Contractor: _ 'I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation "
OWNER -BUILDER DECLARATION -' insurances carrier and policy number are:
1 hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier Policy Number
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to I certify that, in the performance of the work for which this permit is issued, I shall not employ any --
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the _ person in any manner so as become subject to the workers' compensation laws of California,
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I sho a mst to the workers' compensation provisions of Section -
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the Labor de, I N'# rt with comply with those provisions.
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1, Date, 9 J 1�tpplicant: -
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and --
_ the structure is not intended or offered for E W sale ISec. 7044, Business and Professions Code: The WARNING: FAILURE TO SE RS'COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER 0 CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
( I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to.the Contractors' State License Law.). -
1 _ 1 I am exempt under Sec. , B.&P.C. for this >7n
Date: / -I 7- fO Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury at there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subjectto the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and stale that the abo information is correct. I agree to comply with all
city and county ordinances and state laws relating to buil ' c nstr 'on, and hereby authorize representatives
of this county ttt000 enter
upon the above-mentioned pro y fo in ec on purposes.
Date: ! �!' /'Signature (Applicant or Age t):
Application Number .
. . 10-00000616
------ Structure Information
185 SF ADDTN TO EXIST. SFD
-----
Construction Type . .
. . .. TYPE V, UNPROTECTED
Occupancy Type . . .
. . . DWELLG/LODGING/CONG <=10.
Other struct info . .
. . . CODE EDITION
2007/08 ENERGY
FLOOD ZONE
NO
--------------------------------------
1ST FLOOR SQUARE FOOTAGE
--------------------------------------
185,.00
Permit . . . BUILDING PERMIT
Additional desc .
Permit Fee.
207.00 Plan Check Fee
134.55
Issue Date . . . .
Valuation .
. . 20000
Expiration Date
3/16/11
Qty Unit Charge
Per
Extension ,
BASE FEE
45.00
18.00. 9.0000
THOU. BLDG 2,001-25,000
162.00
Permit . . . MECHANICAL
Additional desc ..
Permit Fee . . . .
24.00 Plan Check Fee
6.00
Issue Date
Valuation
0
Expiration Date
3/16/11
Qty Unit Charge
Per
Extension .
BASE FEE
15.00
2.00 4.5000
-----------------------------------------------------------------------------
EA MECH VENT INST/ DUCT ALT
9.00
Permit.
ELECT - ADD/ALT/REM
Additional desc .
Permit Fee . .
22.23 Plan Check Fee
'. 5.56
Issue Date . . . .
Valuation . .
. . 0
Expiration Date
3/.16/11
Qty Unit Charge
Per
Extension
BASE FEE
15.00
185.00 .0350
ELEC NEW RES - 1 OR 2'FAMILY
6.48
1.00 .7500
----------------------------------------------------------------------------
PER ELEC DEVICE/FIXTURE 1ST 20
.7S
- Permit . . .
GRADING PERMIT
Additional desc .
Permit Fee
15.00 Plan Check Fee
.00
Issue Date . . . .
Valuation
0
Expiration Date
3/16/11
LQPERMIT
Application Number . . . . . 10-00000616
Permit . . . . . . GRADING PERMIT
Qty Unit Charge Per
Extension
BASE FEE
15.00
------------ ---------------------------------------------------------------
-----------
Special Notes and Comments
Special
185 SF COMPUTER ROOM ADDITION TO
EXISTING SFD - GAME ROOM LOCATION. R-3
OCCUPANCY.TYPE V -B CONSTR. 2007/2008
ENERGY CODES.
--------------------------------------------------------
Other Fees . . . . . . . BLDG STDS ADMIN
(SB1473)
1.00
ENERGY REVIEW
FEE
13.46
STRONG MOTION
(SMI) - RES
2.00
Fee summary Charged Paid
Credited
Due
Permit Fee Total 268.23 .00
.00
.268.23
Plan Check Total 146.11 .00
.00
146.11
Other Fee Total 16.46 .00
.00
16.46
Grand Total 430.80 .00
.00
430.80
LQPERMIT
Bin #1
City of La Quetta
Building a Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
1��1
Project Address:Lf
Owner's Name: L—C9AJL
A. P. Number:
Address: U 0 14 5 V /A
Legal Description:
City, ST, Zip: L-t"n- (�-JzV ( &
Contractor:
�% l 7 r �7
telephone: ci
p L " Z 25 [
'y::i?><<?':'•'?«> <' `':
::.:; ::: ;;i::::..:::•i:::> ::•:>:;:;;:;<.:<i
x,%:...� c....:i:
Address:
Project Description:
City, ST, Zip:
tin i v( cU
Telephone:
;>::::z•':z;:tir>:f<:.a::>::;��::>:>:>•>:>;::»:::•r;<
State Lic. # :
City Lic. #;
Arch., Engr., Designer: &Y god
Address: 4 �5
City., ST, Zip: Lk— Qo ( K l k-
Tele hone: G 23
�'ki::tii:p\j:.l�;•vyi:iri,i:4:i• •tir:i. �{ 'LN...y •...{•.
•.{iti:<.'Jr is iy:: 4iY«:�4li..t::•i.y,:.;�..T':::
:t;.;3?<r;,y»r :r»;::
::�.. :.•c.
Construction Type: Occu anc
J
type one): )� Project a New Add'n Alter Repair Demo
State Lic. #: G S �5
Name of Contact Person: LA v
RCO t�q,Z
Sq. Ft.: �
# Stories:
#Units:
Telephone # of Contact Person: (' �j 6 4- (j 7 9 o
Estimated Value of Projec . , O
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMFr FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
�/
Reviewed, ready for corrections
3
Plan Check Deposit
Truss Calcs.
I
Called Contact Person
7 '3)
Plan Check Balance.
Title 24 Calcs.
010.Plans
picked up oQ
Construction
Flood plain plan
I
!
Plans resubmitted
Mechanical
Grading plan
2°" Review, ready for correction rissue
1
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
i
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Review, ready for correctionstiissue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
j
Date of permit issue
'
School Fees
-1ks
Total Permit Fees
I
Coachella Valley Unified School District -This
Box For District Use Only � `" ,' - • ` *' . -
83-733 Avenue 55 Thermal CA, 92274 C DEVELOPER FEES PAID
(760) 398-5909 — Fax (760) 398-1224 t
AREA: .. - r: -'
AMOUNT
LEVEL ONE AMOUNT : -
; LEVELTWO AMOUNT:
MITIGATION AMOUNT:
COMMAND. AMOUNT:
DATE:' • :.t :, , -
RECEIPT: '
' CHECK #:
INITIALS: '
CERTIFICATE OF COMPLIANCE �•
• t (California Education Code 17620)
Project Name: ' Mountain View Country Club r }Date: September ,17, 2010
Owner's Name: Dale Weaver "' ' ' Phone No. 760-601-09111
Project Address:. 80-495 Via Talavera, LaQuinta,.CA _ ` '~•' t•
Project Description: Addition to Game'Room r
APN: 777-270-031 Tract#.. {, r •' Lot #'s: `*
Type of Development: Residential 'i i� Vii'.•'; ; -Commercial Industrial
' Total Square Feet of Building Area: 185 sq. ft.
Certification of Applicant/Owners: "The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/sheds authorized to on behalf of the owner/developer.
Dated: September 17, 2010 ' • Signature-.,,jr.
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT;HAVE BEEN OR WILL BE SATISFIED IN.
-ACCORDANCE WITH ONE OF THE FOLLOWING: -(CIRCLE ONE)
Education Code Gov. Code f Protects Agreement Existing Not Subject to Fee
,. ,
17620 65995 , ] Approval - Prior. to 1/1/87 Requirement
• �' J Note: Pursuant to AB -181, any room additions of 500 square .
Number of Sq.Ft.' 185 sq. ft �' - feet or less on existing dwelling units are exempt from
Amount per Sq.Ft $ 0.00'' developer fees. Pursuant to AB -181, any mobile home being
Amount Collected $ 0.00 ;. ' .t . I ~ relocated or replaced within our school district is exem i
-11 from deyeloper_fees(
Building Permit Application Completed: Yes/No' ;
:.
Jamie T. Brown, , By: -Asst. Supt., Business Services , :.. ,,. ,� • - '
Certificate issued by: Laurie Howard, Secretary In Signature::'
1 NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES'AND STATEMENT OF FEES y
Section 66020 of the Government Code asserted by Assembly Bill 3081; effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions'(''Fees"); of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to -
advise you that the 90-day,protest period in regard to such Fees or the validity thereof; commences.with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a' Certificate' of Occupancy. -As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for,good cause, as'determined by the School District, and up ,
to three 3 such extensions may be granted.;
MV:c/Inydocs'devfe&ceiiificate of compliance ta•m tables) O USC.doc , •� - i ' 1/16/03 T.
1UL109/2010/FRI 01,23 PM The.Monarch Group FRR No. 76C 776.5111 P.00i/coi
NT AIN �%IEVY
O: U.N T RY.:...C.L U 13 '.
zq La ' Uinta ..
July 8, 2010
Dale Weaver
80-495 Via Talavera
La Quinta, CA 82253
Re: Architectural Request
80•-495 Via Talavera
Dear Mr. Weaver:
The Arch itectu ta I/Landscape Committee of the Mountain View Country Club
Homeowners' Association have reviewed the plans to install an addition to your
home per the application submitted. The committee is pleased to inform you that
it has approved the plans.
Thank you for your patience and understanding during this approval process._ If
there are any questions please contact me at 760-7765100 ext. 351.
Sincerely,
FOR THE BOARD OF DIRECTORS
MOUNTAIN ��VI..��E��W COUNTRY CLUB
J ' mie Hansen,
Association Manager
enclosure
cc: Board of Directors + 1,
Unit File
T
/fJ� 11W(
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Weaver Residence
80495 Via Talavera
La Quinta, CA
Project Designer:
Report Prepared by:
Joan D. Hacker
Insu-form, Inc.
77-810 Las Montana Road, Suite 210
Palm Desert, Ca 92211 .c ,►
760-345-1352 CI
T Y J
LA QUINTq
00
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE 40 BBYP
Job Number: _�_��. ----_
IIJ AUG 2 5 2010 '+
Date:
7/8/2010
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
TABLE OF CONTENTS
PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R
Project Name
Weaver Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
7/8/2010
Project Address
80495 Via Talavera La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,722
Addition
185
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features see Part 2 of 5 Status
Roof Wood Framed Attic R-38 185
New
Wall Wood Framed R-13 245
New
Slab Unheated Slab -on -Grade None 185 Perim = 19'
New
Wall Wood Framed R-13 138
New
Wall Wood Framed R-11 798
Existing
Door Opaque Door None 24
Existing
Roof Wood Framed Attic R-19 4,537
Existing
Slab Unheated Slab -on -Grade None 4,537 Perim = 154'
Existing
FENESTRATION U- Exterior
Orientation Area(ft2) Factor SHGC Overhang Sidefins Shades
Status
Front (NE) 25.0 0.550 0.45 2.0 none Bug Screen
New
Left (SE) 12.5 0.550 0.45 2.0 none Bug Screen
New
Right (NlN) 12.5 0.550 0.45 2.0 none Bug Screen
New
Front (NE) 29.0 0.710 0.73 2.0 none Bug Screen
Existing
Front (NE) 6.0 0.710 0.73 2.0 none Bug Screen
Existing
Front (NE) 24.0 0.710 0.73 2.0 none Bug Screen
Existing
Front (NE) 6.0 0.710 0.73 2.0 none Bug Screen
Existing
Left (SE) 60.0 0.710 0.73 2.0 none Bug Screen
Existing
Left (SE) 42.0 0.710 0.73 2.0 none Bug Screen
Existing
Left (SE) 36.0 0.710 0.73 2.0 none Bug Screen
Existing
Left (SE) 63.0 0.710 0.73 2.0 none Bug Screen
Existing
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat Status
2 Central Furnace 78% AFUE
Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
Living Zone Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution
Status
EnergyPro5.0 by EnergySoft User Number: 2655
RunCode: 2010-07-08T10:10:1 ID:
Page 3 of 13
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Weaver Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
7/8/2010
Project Address
80495 Via .Talavera La Quinta .
California Energy Climate Zone
CA Climate Zone 15
I Total Cond. Floor Area
4,722
Addition
185
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (f Features see Part 2 of 5 Status
FENESTRATION U-
Orientation Area(ft2) Factor
Exterior
SHGC Overhang Sidefins Shades Status
Left (SE) 68.0 0.710
0.73 2.0 none Bug Screen Existing
Left (SE) 8.0 0.710
0.73 2.0 none Bug Screen Existing
Left (SE) 45.5 0.710
0.73 2.0 none Bug Screen Existing
Right (NM 9.0 0.710
0.73 2.0 none Bug Screen Existing
Right (NVI9 64.0 0.710
0.73 2.0 none Bug Screen Existing
Right (NVt9 21.0 0.710
0.73 2.0 none Bug Screen Existing
Right (NlAq 42.0 0.710
0.73 2.0 none Bug Screen Existing
Right (NVI9 20.6 0.710
0.73 2.0 none Bug Screen Existing
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
EnergyPro 5.0 by EnergySoft User Number: 2655 Run Code: 2010-07-08T10:10:1 /D:
Page 4 of 13
PERFORMANCE CERTIFICATE: Residential . (Part 2 of 5) CF-1 R
Project Name
Weaver Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
7/8/2010
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form for each of the measures listed below for final to be given.
EnemyPro 5.0 by EnemySoft User Number: 2655 RunCode: 2010-07-08T10:10:1 /D: Pae 5 of 13
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Weaver Residence
❑ Multi Family m Existing+ Addition/Alteration
7/8/2010
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2 r
Space Heating 2.64 2.64 0.00
Space Cooling 130.87 130.81 0.06
Fans 28.01 28.00 0.01
Domestic Hot Water 8.65 8.65 0.00
Pumps 0.00 0.00 0.00
Totals 170.18 170.11 0.07
Percent Better Than Standard: 0.0%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (NE) 45 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (NE) 372 90
Fuel Available at Site: Natural Gas (SE) 916 335
Raised Floor Area: 0 (SK9 0 0
Slab on Grade Area: 4.722 (NtM 510 169
Average Ceiling Height: 9.0 Roof 4,722 0
Fenestration Average U -Factor: 0.70 TOTAL: 594
Average SHGC: 0.71 Fenestration/CFA Ratio: 12.6
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Insu-form, Inc.
782010
Address 77-810 Las Montana Road, Suite 210 Name Joan D. Hacker
City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone 760-345-1352 ne Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company "Y01LGd��1,1'.�.CTL1��
Address C4 vj 994 Z 6- 51 Name
City/State/Zip CLO (LS—LZ-. Z{-?� PhoneZ(�U -i64 GZ`-�� Signed License # Date
EnemyrPro 5.0 by EnemySoft User Number: 2655 Run Code: 2010-07-08T10:10:1 ID: Page 6 of 13
lib
CERTIFICATE OF COMPLIANCE:
Residential (Part 4 of 5) CF -1 R
Project Name
Weaver Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
7/8/2010
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation
Factor Cavity Exterior Frame Interior Frame Azm
Joint Appendix
Tilt I Status 4 Location/Comments
Roof
185
0.025 R-38
135
0 New 4.2.1-A21
Addition
Wall
107
0.102 R-13
45
90 New 4.3.1-A3
Addition
Slab
185
0.730 None
0
180 New 4.4.7-A1
Addition
Wall
138
0.102 R-13
135
90 New 4.3.1-A3
Addition
Wall
138
0.102 R-13
315
90 New 4.3.1-A3
Addition
Wall
151
0.110 R-11
45
90 Existing 4.3.1-A2
Existing Living
Door
24
1.450 None
45
90 Existing 4.5.1-A1
Existing Living
Wall
218
0.110 R-11
135
90 Existing 4.3.1-A2
Existing Living
Wall
226
0.110 R-11
135
90 Existing 4.3.1-A2
Existing Living
Wall
203
0.110,R-11
315
90 Existing 4.3.1-A2
Existing Living
Roof
4,537
0.049 R-19
45
0 Existing 4.2.1-A4
Existing Living
Slab
3,537
0.730 None
0
180 Existing 4.4.7-A1
Existing Living
Wall
210
0.110 R-11
45
90 Remove 4.3.1-A2
Existing Living'
Slab
1,000
0.730 None
0
180 Existing 4.4.7-A1
Existing Living
FENESTRATION SURFACE DETAILS
ID
I Type
Area U -Factor
SHGC2
Azm Status
Glazing Type
Location/Comments
1
Window
25.0 0.550 NFRC
0.45 NFRC
45 New
IWC 6200 Alum/Low-E
Addition
2
Window
12.5 0.550 NFRC
0.45 NFRC
135 New
IWC 6200 Alum/Low-E
Addition
3
Window
12.5 0.550 NFRC
0.45 NFRC
315 New
IWC 6200 Alumkow-E
Addition
4
Window
20.0 0.710 Default
0.73 Default
45 Existing
Double Metal Clear
Existing Living
5
Window
9.0 0.710 Default
0.73 Default
45 Existing
Double Metal Clear
Existing Living
6
Window
6.0 0.710 Default
0.73 Default
45 Existing
Double Metal Clear
Existing Living
7
Window
24.0 0.710 Default
0.73 Default
45 Existing
Double Metal Clear
Existing Living
8
Window
6.0 0.710 Default
0.73 Default
45 Existing
Double Metal Clear
Existing Living
9
Window
12.0 0.710 Default
0.73 Default
45 Removed Double Metal Clear
Existing Living
10
Window
60.0 0.710 Default
0.73 Default
135 Existing
Double Metal Clear
Existing Living
11
Window
42.0 0.710 Default
0.73 Default
135 Existing
Double Metal Clear
Existing Living
12
Window
36.0 0.710 Default
0.73 Default
135 Existing
Double Metal Clear
Existing Living
13
Window
63.0 0.710 Default
0.73 Default
135 Existing
Double Metal Clear
Existing Living
14
Window
68.0 0.710 Default
0.73 Default
135 Existing
Double Metal Clear
Existing Living
15
1 Window
8.0 0.710 Default
0.73 Default
135 Existing
Double Metal Clear
Existing Living
16Window
45.5 '0. 710Default
0.73 Default
1351 Existing
Double Metal Clear
Existing Living
(1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H76TT Wd
Ove hang Left Fin
Len H t LExt RExt Dist Len
Right Fin
H t Dist Len H t
1
Bug Screen
0.76
5.01 5.0
2.0 0.1
2.0 2.0
2
Bug Screen
0.76
5.0 2.5
2.0 0.1
2.0 2.0
3
Bug Screen
0.76
5.0 2.5
2.0 0.1
2.0 2.0
4
Bug Screen
0.76
5.0 4.0
2.0 0.1
2.0 2.0
5
Bug Screen
0.76
3.0 3.0
2.01 0.1
2.0 2.0
6
Bug Screen
0.76
4.0 1.5
2.0 0.1
2.0 2.0
7
Bug Screen
0.76
4.0 6.0
2.0 0.1
2.0 2.0
8
Bug Screen
0.76
4.0 1.5
2.0 0.1
2.0 2.0
9
Bug Screen
0.76
4.0 3.0
2.0 0.1
2.0 2.0
10
Bug Screen
0.76
6.8 9.0
2.0 0.1
2.0 2.0
11
Bug Screen
0.76
7.0 6.0
2.0 0.1
2.0 2.0
12
Bug Screen
0.76
6.0 6.0
2.0 0.1
2.0 2.0
13
Bug Screen
0.76
7.0 9.0
2.0 0.1
2.0 2.0
14
Bug Screen
0.76
8.5 8.0
2.0 0.1
2.0 2.0
15
Bug Screen
1 0.76
1.01 8.0
2.0 0.1
2.0 2.0
16
]Bug Screen
0.76
7.01 6.5
2.0 0.1
2.0 2.0
EnergyPro
5.0 by EnergySoft User Number: 2655
RunCode: 2010-07-08T10:10:1 ID:
Page 7 of 13
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R
Project Name
Weaver Residence
Building Type m Single Family ❑ Addition Alone
o Multi Family m Existing+ Addition/Alteration
Date
7/8/2010
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Type Area
Ll -Factor' SHGC
Azm Status Glazing Type Location/Comments
17 Window 9.0
0.710 Default 0.73 Default 315 Existing Double Metal Clear Existing Living
18 Window 64.0
0.710 Default 0.73 Default 315 Existing Double Metal Clear Existing Living
19 Window 21.0
0.710 Default 0.73 Default 315 Existing Double Metal Clear Existing Living
20 Window 42.0
0.710 Default 0.73 Default 315 Existing Double Metal Clear Existing Living
21 Window 20.6
0.710 Default 0.73 Default 315 Existing Double Metal Clear Existing Living
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID Exterior Shade Type
Window
SHGC H t Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len H t Dist Len H t
17 Bug Screen
0.76 6.0 1.5 2.0 0.1 2.0 2.0
18 Bug Screen
0.76 8.0 8.0 2.0 0.1 2.0 2.0
19 Bug Screen
0.76 7.0 3.0 2.0 0.1 2.0 2.0
20 Bug Screen
0.76 7.0 6.01 2.0 0.1 2.0 2.0
21 Bug Screen
0.76 4.0 5.2 2.0 0.1 2.0 2.0
EnergyPro 5.0 by EnergySoft
User Number. 2655
Run Code: 2010-07-08T10:10:1 /D: Page 8 of 13
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5)
CF-1 R
Project Name
Weaver Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
7/8/2010
BUILDING ZONE INFORMATION
System Name
Zone Name
Floor Area
New Existinq Altered Removed Volume
Year Built
Living Zone Addition
185 1,480
Existing Living
4,537 40,833 1987
Totals 185 4,537 0 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type
Status
Living Zone
2 Central Fumace
78% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name
Heating
Duct Ducts
Cooling Duct Location R-Value Tested? Status
Living Zone Ducted
Ducted Attic, Ceiling Ins, vented 4.2 ❑
Existing
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
No Pipe Insulation
40,000
50
0.53
n/a
n/a
Existing
MULTI-FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
E
E
w °'
w
Hot Water Piping Length
ft
o
•6
-0 N
a c
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qt . HP
Plenum Outside Buried
❑
❑
❑
❑
❑
Et
❑
EnemyPro 5.0 by EnemySoft
User Number: 2655
Run Code: 2010-07-08T10:10:1 ID:
Pa e 9 of 13
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Weaver Residence
Date
1 7/8/2010
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
§150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no qreater than 2.0 permfinch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight-fifting tight-fittingdamper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
§150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
§150(i): He ating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculatinq sections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
§150(i)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind.
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro5.0 by EnergySoft User Number: 2655 RunCode: 2010-07-08T10:10:14 /D: Page 10 of 13
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Weaver Residence
7/8/2010
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
ro rammed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ftz may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro5.0 by EnergySoR User Number. 2655 RunCode: 2010-07-08T10:10:14 /D: Page 11 of 13
V
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name _
Date
Weaver Residence
7/8/2010
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be hi h efficacy luminaires.
§150(k)14: Internally illuminated address signs shall'comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
f
,
t
EnergyPro5.0 by EnergySoff User Number: 2655 Run Code: 2010-07-08T10:10:14 ID: Page 12 o/ 13
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Weaver Residence
Date
7/8/2010
System Name
Living Zone
Floor Area
4,722
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
-COIL COOLING PEAK
CFM Sensible
Total Room Loads 4,804 64,523
Return Vented Lighting 0
Return Air Ducts 7,193
Return Fan 0
Ventilation 0 0
Supply Fan 0
Supply Air Ducts 7,193
TOTAL SYSTEM LOAD 78,909
COIL HTG.
Latent CFM
4,936 1,575
0 0
4,936
PEAK
Heating System
Sensible
Output perSystem 56,000
53,887
Total Output Btuh 112,000
Output Btuh/s ft 23.7
4,690
Cooling System
0
Output perSystem 42,000
0
Total Output Btuh 84,000
0
Total Output ons 7.0
4,690
Total Output Btuh/s ft 17.8
Total Output s ft/Ton 674.6
63,268
Air System
CFM perSystem
1,500
HVAC EQUIPMENT SELECTION
Airflow cfm
3,000
Exist 53,064
25,694
112,000
Airflow cfm/s ft
0.64
Airflow cfm/Ton
428.6
Outside Air %
0.0%
Total Adjusted System Output 53,064
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
25,694
Aug 3 PM
112,000
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions 1
r Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak)
26 OF 69 OF
Outside Air
0 cfm Supply Fan
3,000 cfm
69 OF
69 OF 104 OF
Heating Coil
102 OF
--. .r
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 80/68°F 80/68°F 63/62°F
Outside Air Ar
0 cfm Supply Fan Cooling Coil
3,000 cfm......
fm4S,
59.1 %
80 / 68 OF
65 / 63 OF
ROOM i-.:, .
78168 OF
EnergyPro5.0 by EnergySoft
User Number. 2655 RunCode: 2010-07-08T10:10:14 /D:
Page 13 of 13