04-7821 (SFD)01
Q40
BUILDING & SAFETY DEPARTMENT,,
w� P.O. Box 1504
G't
;t (760).777-7012
� 9
--,7 LLE TAMPICO",
DF -
FAX FAX (760) 777=7011
�•A CALIFORNIA'92253 INSPECTION' REQUESTS (760) 777-7153_
BUILDING -PERMIT
ITY OF LA QUIWTA
APPS P' 04 X0.00„078.21 Date 1/21/05
operty. Address 78935 VISA VENTAN~A
: APN:; 646-330-026-
`Application description DWELLING - SINGLE FAMILY DETACHED
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation 385.46
Owner Contractor.
QUAD D A LTD..PARTNERSHIP KIRK CONSTRUCTION' INC, MIKE
5 PEPPERWOOD DR 7,2677 -BEAVERTAIL STREET
SANDY, UT 84092 PALM `'DESERT CA 92260
(760) `.346-1820
E WCC STATE FUND
WC: 10.90480 01/01/06
CSLB: .521890 12/31/05
CCC: B
-.-- Structure InformationA56 SQ..ET.,CASITA ----
Construction Type TYPE V ”- NON -RATED
Occupancy Type DWELLG/LODGING/LONG <=10
Flood Zone NON -AO' FLOOD ZONE
Other struct info CODE EDITION: 2001 CBC
# BEDROOMS, 1.00 .
FIRE ,SPRINKLERS ' NO
PATIO, SQ FTG 128.00
NUMBER)`OF.'UNITS . 1,00
1ST.FL'OOR'SQUARE FOOTAGE 456.00
Permit BUILDING PERMIT
Additional'desc
Permit Fee 343.00 Plan'Check-Fee 222.95
Issue Date Valuation 38546
Expiration, Date 7/21/0.5.
Qty Unit Charge_ Per Extension
BASE FEE 252.00
14.00 6.5000 THOU' BLDG.25,001•-50,0.00 91.00
- -I ,
Permit ELEC-:NEW RESIDENTIAL. s
Additional desc,.
Permit Fee 30.96 Plan Check Fee 7.:74
'Issuenate Valuation 0
Expiration Date 7/21/05 )
Qty Unit Charge, Per Extension
BASE FEE 15.0-:0
456.00 .0350. ELEC NEW RES 1 OR 2 FAMILY 15.96
P.O. BOX 1504
78-495 CALLS TAMPICO VOICE (760) 777-7.012 _ FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT
Application Number: e a Date: / -a 1.05
Applicant: I Architect or Engineer:
Applicant's Mailing Address:
Architect or Engineer's Address:
No..
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
C de, and myLicens is in full force and effect.
License Class ' ense No. G
G" -6WNER-BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and -the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant fora permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
U I am exempt under Sec. , BA P.C. for this reason
Date
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
/Carrier
sued. � rs�' co^rn� nsation� ince carrier n oIiC)�Aum r
ME�,�( _ r ! ' oiP lice Number _� !p a
I certify that, in'the performance of the work for which this pe it is issued, 0all� not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree t if I should becoo sub to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with those provisions �� I ��
WARNING: FAILURE TO SECAE-WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name
Lender's Address A
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its -
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with ity and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this county to enter on the abentione ro effy for inspection purposes.
Z /-��,
ate nature (Applicant or Age .
Page
2
Application Number
0`4=00007821:Date
1/21/05
Permit
MECHANICAL
Additional des:
Permit Fee`
39.5D Plan Check Fee :
9.88
Issue Date
Valuation'
0
Expiration Date
7./21/,05
Qty'Charge""
Per
Extension
.'Unit
BASE FEE
15:00
1 . 00 . , `, 9.•0000,
EA MECH FURNACE <=10K
9.00
1.00- 9.0000
EA MECH B/C <=3HP/100K BTU
9.00
1.00 .6 ..5-0 0 0.
EA MECH , VENT FAN
6.50
------------------------------------
Permit
PLUMBING
Additional des_:
-'Permit. Fee
64.50 Plan Check Fee
16.13
Issue Date
Valuation . .
0
Expiration Date
7/21/05
Qty Unit Charge
Per
Extension
BASE.FEE
15.00
3.00 6.0000
EP,.,"'PLB FIXTURE
18.00
1.00 7.5000
EA PLB WATER HEATER/VENT
7.50
1.00 3.000'0,EA
PLB WATER INST./ALT/REP.
3.00
2.00 3.0000
EA'' PLB GAS PIPE 1-4:OUTLETS
6.00
1.00 15.0000
EA. PLB GAS METER
15.00
Special Notes and Comments
456sq.` .ft : CASITA AND,
,PATIO 128' SQ. FT. '
1/20/05"6•:11:07 AM jjohnson
Other Fees
.. ART IN PUBLIC PLACES -RES
.00
- ENERGY REVIEW FEE:"
22.30
STRONG MOTION (SMI) - RES
3..85
Fee summary Charged,
Paid- Credited
Due,
Permit Fee Total" .
477. 96 _0000
477-."96
Plan Check Total-;
256.7.0. .00 00
256.70
Other.Fee Total."'
26.15 .00 .00
26.15'
;Grand Total
°760A1 : 00 .00
760.81
A
X
B`°#
Permit-ff.
Project Address:
City of La Quinta
r Building at Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
V) A V'e,1 +ANf Q Owner's Name: QUA p -D (7z9-i-Je2SN
A. P. Number:
_ 3 3 0- 0zL
Address:
Legal Description:
Cite, ST, Zip: SA"In "U —
Contractor: M I ke V, tG CpI�S
F Telephone: 001 ISI('C>-75's
Address: -72 61-7
S&Ave21-A1
Project Description:
City, ST, Zip: -PALM besea
C� Srt h oIJS
Telephone: 34to
I gjzo-
,-
State Lic. # : 02 1 Sal 0
City Lic. #:
Arch., Engr., Designer:
Address:
City, ST, Zip:
Telephone: `7=""`' �:-;= -
p x . :.;
State Lic. #: -
Name of Contact Person: I (C -p— Kt GLI'-
Construction Type: Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
X Sq. Ft.: 4,S # Stories: ( # Units: I
Telephone # of Contact Person: 1&0 13 0220
stimated Value of Project: :45 oo p
APPLICANT: DO NOT WRITE BELOW THIS LINE
# 7 Sub m' tal
Req'd
Rec'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
n Check Deposit
rues Calcs
Called Contact Person
Plan Check Balance
-Energy Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2" Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
` H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
''' Review, readv for correctionsfissue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I:P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
CERTIFICATE OF COMPLIANCE J�1Fll ns�,
Desert Sands Unified School" Districti PCT. R. "i;
`'
47950 Dune Palms Road `ZC BERMUDA DUNES
RANCHO MIRAGE CJ
Date 1/20/05.1 La Quints, CA 92253 N INDIAN WELLS ,
d. PALM DESERT
No. 26794 17601 771-8515 _LA QUINTA
INDIO
Owner Quad D.Partnership APN # 646-330-026
Address Jurisdiction 'La Quints
City Zip -Permit #
Tract # Study Area
Type Residential Addition No of Units 1
Lot # No. Street, S.F. Lot # . : No.". Street S.F.
Unit 1 78935 Via Ventana 456: Unit 6
Unit 2
Unit 7
Unit 3 Unit 8
Unit 4 'Unit 9
Unit 5. Unit 10
Comments Detached Guest House
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do'. not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is.ekernpt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school' -facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq
in the amount of $2.24 X 456 . S. F. or $1;021.44 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. , e
Fees Paid By Cash - Mike Doolin Check No.
Name on"the check Telephone 771=3654
Funding Residential
By Dr. Doris Wilson
Superintendent
Fee collected /exempted by Sharon: MCGllvrey Payrrient Recd
$1,021.44 Over/Under
. c .
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to "notify you that the 90 -day approval period in which you may protest the fees o
r other payment identified above will begin to run from the date on which the building or installation permit forthis'project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALiD:if'Duplicated -
Embossed Original - Building Department/Applicant ., ;:Copy - Applicant/Receipt Copy -Accounting
�_:
y
� ' - � ..
.. � �
Type
y
Area
^. i ,
Ce' rtificate of Compliance: Residential Part 1 of 2 ' CF -1 R
N )
Exterior
Overhang Side Fins
MR. MIKE•DOOLIN
1/10/2005
Project Title ,
Date
78-935 VIA VENTANA
,LA QUINTA
Project Address
Building Permit # ^
GLS Group
(760) 340-3528 Plan check 1 Date
Documentation Author
Telephone
Computer Performance
15 Field Check 1 Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Left
Total Conditioned Floor Area:-
456 f? f Average Ceiling Height: 9.0 ft
Total Conditioned Slab Area:
456 ft2 -
Building Type:
x -
(check one or -more),
Right
X❑ Single Family•Detached
❑ 'Addition - ' -
❑ Single Family Attached
E Existing Building r !'
❑ Multi -Family
❑' Existing Plus Addition l
Front Orientation: (North) 0 dei: Floor Construction Type: Slab Floor
Number of Dwelling Units:
1:00 r µ '
Number of Stories:.
T". "' ❑ Raised Floor
BUILDING SHELL INSULATION
,.
' Const.
•
Component
.'Frame Assembly 'Location/Comments
Type
Type '` U -Value (attic, garage, typical, etc.)
R-38 Roof (R.38.2x4.24)
Wood 0.024 Exterior Roof
Slab On Grade
n/a .. . 0.756 Covered Slab w/R-0.0 Perimeter Insulation
M
R-19 Wall w/1" EPS -
Wood 0.045 Exterior Wall
Solid Wood Door
None. ',' 0.387 'Exterior Door:.
FENESTRATION
' Ch�rlinn rinvinnc
Type
Orientation
Area
^. i ,
Fenestration
Exterior
Overhang Side Fins
SF
U -Factor
SHGC ' -
ShadingYes
/ No
Yes / No .
Front
(North)
32.0
0.31
0.37
Bug Screen -
❑ X❑
❑ X❑
Left
(East)
36.0-
0.34 < -. '
• 0.28
Bug Screen
❑, X❑
❑ X❑
Right
(West)
8.0
0.34
0.41 '?'
Bug Screen :
❑ X❑
❑ X❑
,.
r
•
❑ ❑
❑ ❑
M
❑ ❑
❑ ❑
1:1
El El
❑❑
1:1 EJ
Y
El
s ?
4,
i❑ ❑
❑ ❑
Run Initiation. Time: 01110105 10:08:18 Run Code: 1105380498
Ener
Pro 3.1 By Ener Soft
'
User Number: 5553
Job Number: ADY93-1004
Pa e:3 of 12
Certificate of Compliance: Residential (Part2 of 2) CFA R
MR. MIKE DOOLIN 1/10/2005
Project Title Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution - -
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping 1 Thermostat Location ;
pump, etc.) ('AFUE/HSPF)(ducts, attic, etc.) R -Value .Type Comments
Central Furnace 80% AFUE Ducts in Attic 42 SetbackHVAC S I�ystem
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location DuctThermostat Location
heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments
Split Air Conditioner 12.5 SEER -Ducts in Attic 42 F Setback HVACSplit System
WATER HEATING SYSTEMS Rated 1, ,Tank Energy Facts 1 External
Water Heater Water Heater Distribution # in Input Cap. or Recovery, Standby Tank Insul.
System Name Type, Type ,8yst. Btu/hr (gal) Efficiency Loss (%) ,R -Value
Standard gas 50 gal or less Small Gas Standard - 1 40,,000 50 -0.52 n/a 12
1 For small gas storage (rated inputs of less than or equal to 75;000 Btu/hr), electric resistance and heat pump water heaters, list `energy factor.`.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. ,
REMARKS
^/11111M IA\I^rATCRfi C&IT
' VV111r LIM19VC JIMIGIYICIYI . -
This certificate of compliance lists the building features and performance specifications'needed'to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance
using duct sealing and TXV's requires installer testing and certification
and field ven lcati y approved HERS rater.
Designer o Owner (per Business & Professions Code)
Documentation Author ,
Name:
Name: ..' ADRIANA GIL
Title/Firm: MIKE DOOLIN
Title/Firm: GLS Group '
Address: 78-935 VIA VENTANA
Address. 74-854 Velie Way, Suite 5
LA QUINTA , CA 92253 t
Palm Desert, CA 92260
Telephone:
Teleph ne: (760) 340-3528
Lic. #: `
L4L
(signature) I (d
e) , . (signature) . (date)
Enforcement Agency
Name:
;
` Title/Firm:
r r
Address: -
6
Telephone:'
(signature/stamp) (date)
Run Initiation Time: 1/1
:1 Run Code: 1105380498
EnergyPro 3.1 ' By EnergySoft User Number: 5553..'
Job Number: ADY93-1004 - Page:4 of 12
CeWificate of Compliance: Residential (Addendum) CF -1 R
MR. MIKE DOOLIN 1/10/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted.Plan Field
The DHW System "Standard gas 50 gal: or less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket.
The HVAC System "HVAC Split System " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
Run Initiation. Time: 01/10/0510:08:18 Run Code: 1105380498
EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY93-1004 - Page:5 of 12
Iv
I
t
Measures Checklist: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whetherthey are shown elsewhere in the documents or on this checklist only.
DESCRIPTION instructions: Check or initial applicable boxes or enter N/A if not applicable.
-DESIGNER
ENFORCEMENT
Building Envelope Measures
-§150(a): Minimum R-19 ceiling insulation.
150(b): Loose fill insulation manufacturer's labeled R -Value.
Minimum R-13 wall insulation in wood framed walls or equivalent U -value in, metal frame walls (does
1XI*§150(c):
not apply to exterior mass walls).
0*§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.
§150(1): Slab edge insulation- water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
[X] § 118: Insulation specified or installed meets insulat'ionquality standards. Indicate type and form.
§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit.air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar,Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. -
150(g): Vapor barriers mandatory in Climate Zones 14,apd 16 only.
150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
150(e): Installation of Fireplaces, Decorative Gas`Appliances and Gai Logs.
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allo;ed.
Space Conditioning, Water Heating and Plumbing System Measures
[X] §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
§150(h): Heating and/or cooling loads calculated in accorda . no e with ASHRAE, SMACNA . or RCCA.
§150(i): Setback thermostat on all applicable heating'and/or cooling systems...
'FX §1500): Pipe and Tank Insulation,
1. Storage gas water heaters rated with an EnergyFact6r less than 0,58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks,,or other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
hs.
5. Cooling system piping below 55 degrees F insulated.,
6. Piping insulating between heating source and indirect hot water tank.
,EnergyPro 3.1 By EnergySoft User Number: 5553 'Job Number: ADY93-1004 Page:6 of 12
Wandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
By EnergySoft
a1150(m); Ducts and Fans
Job Number: 'ADY93-1004
Page:7 of 12
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998CIVICSections 601,
603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct-closure,system
that meets the applicable requirements of UL181, UL181A, or UL181 B: If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed. sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back tubber adhesive
duct tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of -the material.
X❑ § 114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance .
heating, and no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or `
spas.
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
X❑ § 115; Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ."
❑ §118 (f): Cool Roof material meet specified criteria
Lighting Measures
a§ 150(k)1: Luminaires for general lighting in kitchens shall have'lamps with an efficacy 40 lumens/watt or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on`a readily accessible lighting
control panel at an entrance to the kitchen.
FV §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2:; and recessed ceiling fixtures are IC (insulation cover) approved.
3.1
By EnergySoft
User Number.,5553
Job Number: 'ADY93-1004
Page:7 of 12
Computer Method Summa
# of
Part 1 of 3 C-2R
-MR-M.I.KE_DQ.QLI.N
Floor Area
11_1.0/_2QQ5
Project Title
.H -VAC -Split -System
Date
_7_8-93.5_VJA_V_ENTA_ NA—LA
Q_U_I.NTA
Conditioned_ -Setback— 2 —n/a
Project Address
Building Permit #
G_LS_Gr_o_up
(760) 340-3528
Documentation Author
Telephone
Plan Check/Date
Cbmputer_P_erf_oman ce
Solar
15
Field Check/Date
Compliance Method (Package or Computer)
Climate Zone
Source Energy Use
Standard
Proposed
Compliance
Tilt
(kBtu/sf-yr)
Design
Design
Margin
—0.024
Space Heating
0.57
0.10
0.47
-R-R_38_Roof (R..3.8. 2A.2.4.)
Space Cooling
51.57
46.03
5.54
Domestic Hot Water
40.75
40.73. '
0.02
Door_ 2.4_
Totals
92.89
86.86
6.03
❑
PPrrent hPttPr than Rtanrlarrl
Whole -House
Wall_ 162.
R -9;%
—9-0--9-0-
Total Conditioned Floor Area: . 456 ft2
Building Type: Single Fam Detached
Building Front Orientation: (North) 0 deg
Number of Dwelling Units: 1.00
1
Floor Construction Type: ❑Raised Floor ❑X Slab Floor
Total Fenestration Area: 16.7%
Total Conditioned Volume:
Number of Stories. Total Conditioned Slab Area:
4,104 ft 3
456 ft 2
BUILDING ZONE INFORMATION
# of
Thermostat Vent
Zone Name
Floor Area
Volume Units
Zone Type Type Hgt. Area
.H -VAC -Split -System
456
—4,104 _1...0.0_
Conditioned_ -Setback— 2 —n/a
Solar
OPAQUE SURFACES
Act.
Gains
Type Area
U -Fac.
Azm.
Tilt
Y / N
Form 3 Reference
Location / Comments
.Roof 456_
—0.024
90_
18_
PXC
❑
-R-R_38_Roof (R..3.8. 2A.2.4.)
Whole—House
Wall_ 1.31
—0-.0-4-5-
—0--9.0-
[X�
❑•
R_1.9_W.aII wL1_EP_S -
Whole -House"
Door_ 2.4_
—0.38.7_
—0---90-
.
D-
❑
-Solid Wood -Door
Whole -House
Wall_ 162.
_0.0_45
—9-0--9-0-
[XI
❑-
Rn19_Wall w/-1_EP_S
Whole -House
Wall_ 1-87_
0..0_4.5
_1.8.0
90
[XI
❑
R -1.9 -W -all w/_1_EP_8
Whole -House
Wall_ 1.9.0
_0..045_
—27-0--90
[X
❑
R_1.92WaII w/_1=EP_S
Whole -House
El
El
i u u
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
Run Initiation Time: 01/10/0:
EnergyPro 3.1 By EnergySoft User Number: 5553
)8:18 Run Code: 1105380498
Job Number: ADY93-1004
of 12
Computer Method Summary
(Part 2 of 3) C -2R
MR. MIKE DOOLIN
1/10/2005
Project Title
Date
FENESTRATION SURFACES
U-
Act.
Glazing Type
Location/.
# Type
Area
Factor SHGC
Azm.
Tilt
Comments
_L Window_F_ro.nt (North)
_32.0_
_0-31.0_ _0..3.7_
0_
_9.0. Better -Bu ilt_V_ynil-low E
Whole -Hous
2 Window Left (East)
18.0
0.340
0.28
90
90 Better Built Vynil low E
Whole House
3 Window Left East)_
18.0
0.340
0.28
90
90 Better Built Vynil low E
Whole House
4 Window Right West)
4.0
0.340
0.41
270`
90 Better Built Vynil low E
Whole House
5 Window Right (West) "
4.0 '
0.340.
0.41
270
90 Better Built Vynil low E
Whole House
INTERIOR AND EXTERIOR SHADING
Window
Overhang Left Fin
Right Fin
# Exterior Shade Type
SHGC
Hgt. Wd.
Len. Hgt.
LEA RExt. Dist. Len.
Hgt. Dist. Len. Hgt.
1 Bug Screen
0.76
2
A.76
3 Bug Screen
0.76
4 Bug Screen
0.76
.
5 Bug Screen
0.76,
Run Initiation Time: 01110/05 10_08:18
Run Code: 1105_380498
EnergyPro 3.1 By EnergySoft
User Number: 5553
Job Number: ADY93-1004
Page:9 of 12
EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY93-1004 Page: 10 of 12
Computer Method Summary (Part 3 of 3) C -2R
MR. MIKE DOOLIN
1/10/2005
Project Title
Date
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside
Location
Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val.
Comments
PERIMETER LOSSES
F2 Insulation
Type Length ,Factor R -Val Depth, Location /'Comments
HVAC SYSTEMS
Heating Equipment Minimum. Distribution Type
Type (furnace, heat- Efficiency and Location Duct'; Thermostat
Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type
Comments
Centrel Furnace 8004.AFUEDucts in Attic 4.2 Setback
HVAC Split System
Hydronic Piping Pipe Pipe Insula
System Name Length Diameter . Thick.
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location' Duct Thermostat
Location /
heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type
Comments
Split Air Conditioner 12.5 SEER Ducts in Attic 4.2 Setback
HVAC Split System
WATER HEATING SYSTEMS Ratedl Tank
Energy fact! 1 Tank Insul.
Water Heater Water Heater Distribution # in Input Cap.
or Recovery Standby R -Value
System Name Type Type Syst. Btu/hr (gal)
Efficiency Loss (%) Ext.
Standard gas 50 gal. or less Small Gas_ Standard 1- 40 000 50
0.52 n/a 12
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby
Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
�t
,;REMARKS
EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY93-1004 Page: 10 of 12
Computer Method Summary (Addendum) C -2R
MR. MIKE DOOLIN ' 1/10/2005
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in.this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
oases on Erie auequacy or the special Jusurication ano aocumentation suomiaea. Plan Field
The DHW System "Standard gas 50 gal. or less" Energy Factor =.0.525. An EF below,0.58 requires an R-12 External Blanket.
The HVAC System "HVAC Split System " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
Run Initiation Time: 01/10/05 10:08:18 Run Code: 1105380498
!nergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY93-1004 Page: 11 of 12
(1
IHVpC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
MR. MIKE DOOLIN 1/10/2005
SYSTEM NAME, FLOOR AREA
HVAC Split System 456
Number of Systems
1
Heating System
Output per System
32,000
Total Output (Btuh)
32,000
Output (Btuh/sgft)
70.2
Cooling System
Output per System
18,600
Total Output (Btuh)
18,600
Total Output (Tons)
1.5
Total Output (Btuh/sgft)
40.8
Total Output (sgft/Ton)
294.2
Air System
CFM per System
650
Airflow (cfm)
650
Airflow (cfm/sgft)
1.43
Airflow (cfm/Ton) "
419.4
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting.
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts .
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
I Sensible
252
51241
212
68:
3,321
0
650 cfm
262
166
0
0
0
0
0
0
0
0
-
0
'262
166
TOTAL SYSTEM LOAD 1 5,7651 3,653
York H4DH018/P4HUA08LO32'U&H 14,036 1,705 32,000
Total Adjusted System Output '- 14,0376F771,705 1 32,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 1 Jan 12 am
/EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
26.0 OF 69.8 OF 69.80E .1'16.0 OF
Outside Air
O: Supply Air Ducts
0 cfm
. o
Supply Fan Heating Coil
115.8 F
650 cfm
ROOMS
70.0 °F
69.8 of
Return Air Ducts
I
DOLING SYSTEM PSYCHROMETRICSAirstream Tem
eratures at Time of Cooling
Peak
111.0177.6 OF
75.4 / 61.6 OF 75.4 ! 61.6 OF
55.1' / 54.0 OF
.1 JJW
O
Supply Air Ducts
Outside Air
0 cfm
Supply Fan Cooling Coil55.5!
54.1 of
650 cfm
ROOMS
46.6%° R.H.
75.4/61.6 OF
75.0161.5 OF
Return Air Ducts
I
EnergyPro 3.1
By EnergySoft User Number: 5553
Job' Number: ADY93-1004
Page: 12 of 12