Loading...
04-7821 (SFD)01 Q40 BUILDING & SAFETY DEPARTMENT,, w� P.O. Box 1504 G't ;t (760).777-7012 � 9 --,7 LLE TAMPICO", DF - FAX FAX (760) 777=7011 �•A CALIFORNIA'92253 INSPECTION' REQUESTS (760) 777-7153_ BUILDING -PERMIT ITY OF LA QUIWTA APPS P' 04 X0.00„078.21 Date 1/21/05 operty. Address 78935 VISA VENTAN~A : APN:; 646-330-026- `Application description DWELLING - SINGLE FAMILY DETACHED Property Zoning: LOW DENSITY RESIDENTIAL Application valuation 385.46 Owner Contractor. QUAD D A LTD..PARTNERSHIP KIRK CONSTRUCTION' INC, MIKE 5 PEPPERWOOD DR 7,2677 -BEAVERTAIL STREET SANDY, UT 84092 PALM `'DESERT CA 92260 (760) `.346-1820 E WCC STATE FUND WC: 10.90480 01/01/06 CSLB: .521890 12/31/05 CCC: B -.-- Structure InformationA56 SQ..ET.,CASITA ---- Construction Type TYPE V ”- NON -RATED Occupancy Type DWELLG/LODGING/LONG <=10 Flood Zone NON -AO' FLOOD ZONE Other struct info CODE EDITION: 2001 CBC # BEDROOMS, 1.00 . FIRE ,SPRINKLERS ' NO PATIO, SQ FTG 128.00 NUMBER)`OF.'UNITS . 1,00 1ST.FL'OOR'SQUARE FOOTAGE 456.00 Permit BUILDING PERMIT Additional'desc Permit Fee 343.00 Plan'Check-Fee 222.95 Issue Date Valuation 38546 Expiration, Date 7/21/0.5. Qty Unit Charge_ Per Extension BASE FEE 252.00 14.00 6.5000 THOU' BLDG.25,001•-50,0.00 91.00 - -I , Permit ELEC-:NEW RESIDENTIAL. s Additional desc,. Permit Fee 30.96 Plan Check Fee 7.:74 '­Issuenate Valuation 0 Expiration Date 7/21/05 ) Qty Unit Charge, Per Extension BASE FEE 15.0-:0 456.00 .0350. ELEC NEW RES 1 OR 2 FAMILY 15.96 P.O. BOX 1504 78-495 CALLS TAMPICO VOICE (760) 777-7.012 _ FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: e a Date: / -a 1.05 Applicant: I Architect or Engineer: Applicant's Mailing Address: Architect or Engineer's Address: No.. BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals C de, and myLicens is in full force and effect. License Class ' ense No. G G" -6WNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and -the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant fora permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is /Carrier sued. � rs�' co^rn� nsation� ince carrier n oIiC)�Aum r ME�,�( _ r ! ' oiP lice Number _� !p a I certify that, in'the performance of the work for which this pe it is issued, 0all� not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree t if I should becoo sub to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions �� I �� WARNING: FAILURE TO SECAE-WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address A APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its - officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with ity and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter on the abentione ro effy for inspection purposes. Z /-��, ate nature (Applicant or Age . Page 2 Application Number 0`4=00007821:Date 1/21/05 Permit MECHANICAL Additional des: Permit Fee` 39.5D Plan Check Fee : 9.88 Issue Date Valuation' 0 Expiration Date 7./21/,05 Qty'Charge"" Per Extension .'Unit BASE FEE 15:00 1 . 00 . , `, 9.•0000, EA MECH FURNACE <=10K 9.00 1.00- 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 .6 ..5-0 0 0. EA MECH , VENT FAN 6.50 ------------------------------------ Permit PLUMBING Additional des_: -'Permit. Fee 64.50 Plan Check Fee 16.13 Issue Date Valuation . . 0 Expiration Date 7/21/05 Qty Unit Charge Per Extension BASE.FEE 15.00 3.00 6.0000 EP,.,"'PLB FIXTURE 18.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.000'0,EA PLB WATER INST./ALT/REP. 3.00 2.00 3.0000 EA'' PLB GAS PIPE 1-4:OUTLETS 6.00 1.00 15.0000 EA. PLB GAS METER 15.00 Special Notes and Comments 456sq.` .ft : CASITA AND, ,PATIO 128' SQ. FT. ' 1/20/05"6•:11:07 AM jjohnson Other Fees .. ART IN PUBLIC PLACES -RES .00 - ENERGY REVIEW FEE:" 22.30 STRONG MOTION (SMI) - RES 3..85 Fee summary Charged, Paid- Credited Due, Permit Fee Total" . 477. 96 _0000 477-."96 Plan Check Total-; 256.7.0. .00 00 256.70 Other.Fee Total."' 26.15 .00 .00 26.15' ;Grand Total °760A1 : 00 .00 760.81 A X B`°# Permit-ff. Project Address: City of La Quinta r Building at Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet V) A V'e,1 +ANf Q Owner's Name: QUA p -D (7z9-i-Je2SN A. P. Number: _ 3 3 0- 0zL Address: Legal Description: Cite, ST, Zip: SA"In "U — Contractor: M I ke V, tG CpI�S F Telephone: 001 ISI('C>-75's Address: -72 61-7 S&Ave21-A1 Project Description: City, ST, Zip: -PALM besea C� Srt h oIJS Telephone: 34to I gjzo- ,- State Lic. # : 02 1 Sal 0 City Lic. #: Arch., Engr., Designer: Address: City, ST, Zip: Telephone: `7=""`' �:-;= - p x . :.; State Lic. #: - Name of Contact Person: I (C -p— Kt GLI'- Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo X Sq. Ft.: 4,S # Stories: ( # Units: I Telephone # of Contact Person: 1&0 13 0220 stimated Value of Project: :45 oo p APPLICANT: DO NOT WRITE BELOW THIS LINE # 7 Sub m' tal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections n Check Deposit rues Calcs Called Contact Person Plan Check Balance -Energy Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. ` H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''' Review, readv for correctionsfissue Developer Impact Fee Planning Approval Called Contact Person A.I:P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees CERTIFICATE OF COMPLIANCE J�1Fll ns�, Desert Sands Unified School" Districti PCT. R. "i; `' 47950 Dune Palms Road `ZC BERMUDA DUNES RANCHO MIRAGE CJ Date 1/20/05.1 La Quints, CA 92253 N INDIAN WELLS , d. PALM DESERT No. 26794 17601 771-8515 _LA QUINTA INDIO Owner Quad D.Partnership APN # 646-330-026 Address Jurisdiction 'La Quints City Zip -Permit # Tract # Study Area Type Residential Addition No of Units 1 Lot # No. Street, S.F. Lot # . : No.". Street S.F. Unit 1 78935 Via Ventana 456: Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 'Unit 9 Unit 5. Unit 10 Comments Detached Guest House At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do'. not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is.ekernpt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school' -facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq in the amount of $2.24 X 456 . S. F. or $1;021.44 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. , e Fees Paid By Cash - Mike Doolin Check No. Name on"the check Telephone 771=3654 Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exempted by Sharon: MCGllvrey Payrrient Recd $1,021.44 Over/Under . c . Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to "notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit forthis'project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALiD:if'Duplicated - Embossed Original - Building Department/Applicant ., ;:Copy - Applicant/Receipt Copy -Accounting �_: y � ' - � .. .. � � Type y Area ^. i , Ce' rtificate of Compliance: Residential Part 1 of 2 ' CF -1 R N ) Exterior Overhang Side Fins MR. MIKE•DOOLIN 1/10/2005 Project Title , Date 78-935 VIA VENTANA ,LA QUINTA Project Address Building Permit # ^ GLS Group (760) 340-3528 Plan check 1 Date Documentation Author Telephone Computer Performance 15 Field Check 1 Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Left Total Conditioned Floor Area:- 456 f? f Average Ceiling Height: 9.0 ft Total Conditioned Slab Area: 456 ft2 - Building Type: x - (check one or -more), Right X❑ Single Family•Detached ❑ 'Addition - ' - ❑ Single Family Attached E Existing Building r !' ❑ Multi -Family ❑' Existing Plus Addition l Front Orientation: (North) 0 dei: Floor Construction Type: Slab Floor Number of Dwelling Units: 1:00 r µ ' Number of Stories:. T". "' ❑ Raised Floor BUILDING SHELL INSULATION ,. ' Const. • Component .'Frame Assembly 'Location/Comments Type Type '` U -Value (attic, garage, typical, etc.) R-38 Roof (R.38.2x4.24) Wood 0.024 Exterior Roof Slab On Grade n/a .. . 0.756 Covered Slab w/R-0.0 Perimeter Insulation M R-19 Wall w/1" EPS - Wood 0.045 Exterior Wall Solid Wood Door None. ',' 0.387 'Exterior Door:. FENESTRATION ' Ch�rlinn rinvinnc Type Orientation Area ^. i , Fenestration Exterior Overhang Side Fins SF U -Factor SHGC ' - ShadingYes / No Yes / No . Front (North) 32.0 0.31 0.37 Bug Screen - ❑ X❑ ❑ X❑ Left (East) 36.0- 0.34 < -. ' • 0.28 Bug Screen ❑, X❑ ❑ X❑ Right (West) 8.0 0.34 0.41 '?' Bug Screen : ❑ X❑ ❑ X❑ ,. r • ❑ ❑ ❑ ❑ M ❑ ❑ ❑ ❑ 1:1 El El ❑❑ 1:1 EJ Y El s ? 4, i❑ ❑ ❑ ❑ Run Initiation. Time: 01110105 10:08:18 Run Code: 1105380498 Ener Pro 3.1 By Ener Soft ' User Number: 5553 Job Number: ADY93-1004 Pa e:3 of 12 Certificate of Compliance: Residential (Part2 of 2) CFA R MR. MIKE DOOLIN 1/10/2005 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution - - Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping 1 Thermostat Location ; pump, etc.) ('AFUE/HSPF)(ducts, attic, etc.) R -Value .Type Comments Central Furnace 80% AFUE Ducts in Attic 42 SetbackHVAC S I�ystem Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location DuctThermostat Location heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.5 SEER -Ducts in Attic 42 F Setback HVACSplit System WATER HEATING SYSTEMS Rated 1, ,Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery, Standby Tank Insul. System Name Type, Type ,8yst. Btu/hr (gal) Efficiency Loss (%) ,R -Value Standard gas 50 gal or less Small Gas Standard - 1 40,,000 50 -0.52 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75;000 Btu/hr), electric resistance and heat pump water heaters, list `energy factor.`. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. , REMARKS ^/11111M IA\I^­rATCRfi C&IT ' VV111r LIM19VC JIMIGIYICIYI . - This certificate of compliance lists the building features and performance specifications'needed'to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field ven lcati y approved HERS rater. Designer o Owner (per Business & Professions Code) Documentation Author , Name: Name: ..' ADRIANA GIL Title/Firm: MIKE DOOLIN Title/Firm: GLS Group ' Address: 78-935 VIA VENTANA Address. 74-854 Velie Way, Suite 5 LA QUINTA , CA 92253 t Palm Desert, CA 92260 Telephone: Teleph ne: (760) 340-3528 Lic. #: ` L4L (signature) I (d e) , . (signature) . (date) Enforcement Agency Name: ; ` Title/Firm: r r Address: - 6 Telephone:' (signature/stamp) (date) Run Initiation Time: 1/1 :1 Run Code: 1105380498 EnergyPro 3.1 ' By EnergySoft User Number: 5553..' Job Number: ADY93-1004 - Page:4 of 12 CeWificate of Compliance: Residential (Addendum) CF -1 R MR. MIKE DOOLIN 1/10/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted.Plan Field The DHW System "Standard gas 50 gal: or less" Energy Factor = 0.525. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC Split System " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS Run Initiation. Time: 01/10/0510:08:18 Run Code: 1105380498 EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY93-1004 - Page:5 of 12 Iv I t Measures Checklist: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whetherthey are shown elsewhere in the documents or on this checklist only. DESCRIPTION instructions: Check or initial applicable boxes or enter N/A if not applicable. -DESIGNER ENFORCEMENT Building Envelope Measures -§150(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturer's labeled R -Value. Minimum R-13 wall insulation in wood framed walls or equivalent U -value in, metal frame walls (does 1XI*§150(c): not apply to exterior mass walls). 0*§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation- water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. [X] § 118: Insulation specified or installed meets insulat'ionquality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit.air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar,Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. - 150(g): Vapor barriers mandatory in Climate Zones 14,apd 16 only. 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. 150(e): Installation of Fireplaces, Decorative Gas`Appliances and Gai Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allo;ed. Space Conditioning, Water Heating and Plumbing System Measures [X] §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accorda . no e with ASHRAE, SMACNA . or RCCA. §150(i): Setback thermostat on all applicable heating'and/or cooling systems... 'FX §1500): Pipe and Tank Insulation, 1. Storage gas water heaters rated with an EnergyFact6r less than 0,58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks,,or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. hs. 5. Cooling system piping below 55 degrees F insulated., 6. Piping insulating between heating source and indirect hot water tank. ,EnergyPro 3.1 By EnergySoft User Number: 5553 'Job Number: ADY93-1004 Page:6 of 12 Wandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) By EnergySoft a1150(m); Ducts and Fans Job Number: 'ADY93-1004 Page:7 of 12 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998CIVICSections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct-closure,system that meets the applicable requirements of UL181, UL181A, or UL181 B: If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed. sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back tubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of -the material. X❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance . heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or ` spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. X❑ § 115; Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ." ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures a§ 150(k)1: Luminaires for general lighting in kitchens shall have'lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on`a readily accessible lighting control panel at an entrance to the kitchen. FV §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2:; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number.,5553 Job Number: 'ADY93-1004 Page:7 of 12 Computer Method Summa # of Part 1 of 3 C-2R -MR-M.I.KE_DQ.QLI.N Floor Area 11_1.0/_2QQ5 Project Title .H -VAC -Split -System Date _7_8-93.5_VJA_V_ENTA_ NA—LA Q_U_I.NTA Conditioned_ -Setback— 2 —n/a Project Address Building Permit # G_LS_Gr_o_up (760) 340-3528 Documentation Author Telephone Plan Check/Date Cbmputer_P_erf_oman ce Solar 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance Tilt (kBtu/sf-yr) Design Design Margin —0.024 Space Heating 0.57 0.10 0.47 -R-R_38_Roof (R..3.8. 2A.2.4.) Space Cooling 51.57 46.03 5.54 Domestic Hot Water 40.75 40.73. ' 0.02 Door_ 2.4_ Totals 92.89 86.86 6.03 ❑ PPrrent hPttPr than Rtanrlarrl Whole -House Wall_ 162. R -9;% —9-0--9-0- Total Conditioned Floor Area: . 456 ft2 Building Type: Single Fam Detached Building Front Orientation: (North) 0 deg Number of Dwelling Units: 1.00 1 Floor Construction Type: ❑Raised Floor ❑X Slab Floor Total Fenestration Area: 16.7% Total Conditioned Volume: Number of Stories. Total Conditioned Slab Area: 4,104 ft 3 456 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area .H -VAC -Split -System 456 —4,104 _1...0.0_ Conditioned_ -Setback— 2 —n/a Solar OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y / N Form 3 Reference Location / Comments .Roof 456_ —0.024 90_ 18_ PXC ❑ -R-R_38_Roof (R..3.8. 2A.2.4.) Whole—House Wall_ 1.31 —0-.0-4-5- —0--9.0- [X� ❑• R_1.9_W.aII wL1_EP_S - Whole -House" Door_ 2.4_ —0.38.7_ —0---90- . D- ❑ -Solid Wood -Door Whole -House Wall_ 162. _0.0_45 —9-0--9-0- [XI ❑- Rn19_Wall w/-1_EP_S Whole -House Wall_ 1-87_ 0..0_4.5 _1.8.0 90 [XI ❑ R -1.9 -W -all w/_1_EP_8 Whole -House Wall_ 1.9.0 _0..045_ —27-0--90 [X ❑ R_1.92WaII w/_1=EP_S Whole -House El El i u u ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 01/10/0: EnergyPro 3.1 By EnergySoft User Number: 5553 )8:18 Run Code: 1105380498 Job Number: ADY93-1004 of 12 Computer Method Summary (Part 2 of 3) C -2R MR. MIKE DOOLIN 1/10/2005 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/. # Type Area Factor SHGC Azm. Tilt Comments _L Window_F_ro.nt (North) _32.0_ _0-31.0_ _0..3.7_ 0_ _9.0. Better -Bu ilt_V_ynil-low E Whole -Hous 2 Window Left (East) 18.0 0.340 0.28 90 90 Better Built Vynil low E Whole House 3 Window Left East)_ 18.0 0.340 0.28 90 90 Better Built Vynil low E Whole House 4 Window Right West) 4.0 0.340 0.41 270` 90 Better Built Vynil low E Whole House 5 Window Right (West) " 4.0 ' 0.340. 0.41 270 90 Better Built Vynil low E Whole House INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 A.76 3 Bug Screen 0.76 4 Bug Screen 0.76 . 5 Bug Screen 0.76, Run Initiation Time: 01110/05 10_08:18 Run Code: 1105_380498 EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY93-1004 Page:9 of 12 EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY93-1004 Page: 10 of 12 Computer Method Summary (Part 3 of 3) C -2R MR. MIKE DOOLIN 1/10/2005 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length ,Factor R -Val Depth, Location /'Comments HVAC SYSTEMS Heating Equipment Minimum. Distribution Type Type (furnace, heat- Efficiency and Location Duct'; Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Centrel Furnace 8004.AFUEDucts in Attic 4.2 Setback HVAC Split System Hydronic Piping Pipe Pipe Insula System Name Length Diameter . Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location' Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Air Conditioner 12.5 SEER Ducts in Attic 4.2 Setback HVAC Split System WATER HEATING SYSTEMS Ratedl Tank Energy fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) Ext. Standard gas 50 gal. or less Small Gas_ Standard 1- 40 000 50 0.52 n/a 12 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. �t ,;REMARKS EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY93-1004 Page: 10 of 12 Computer Method Summary (Addendum) C -2R MR. MIKE DOOLIN ' 1/10/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in.this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies oases on Erie auequacy or the special Jusurication ano aocumentation suomiaea. Plan Field The DHW System "Standard gas 50 gal. or less" Energy Factor =.0.525. An EF below,0.58 requires an R-12 External Blanket. The HVAC System "HVAC Split System " includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS Run Initiation Time: 01/10/05 10:08:18 Run Code: 1105380498 !nergyPro 3.1 By EnergySoft User Number: 5553 Job Number: ADY93-1004 Page: 11 of 12 (1 IHVpC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE MR. MIKE DOOLIN 1/10/2005 SYSTEM NAME, FLOOR AREA HVAC Split System 456 Number of Systems 1 Heating System Output per System 32,000 Total Output (Btuh) 32,000 Output (Btuh/sgft) 70.2 Cooling System Output per System 18,600 Total Output (Btuh) 18,600 Total Output (Tons) 1.5 Total Output (Btuh/sgft) 40.8 Total Output (sgft/Ton) 294.2 Air System CFM per System 650 Airflow (cfm) 650 Airflow (cfm/sgft) 1.43 Airflow (cfm/Ton) " 419.4 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting. Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts . COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 252 51241 212 68: 3,321 0 650 cfm 262 166 0 0 0 0 0 0 0 0 - 0 '262 166 TOTAL SYSTEM LOAD 1 5,7651 3,653 York H4DH018/P4HUA08LO32'U&H 14,036 1,705 32,000 Total Adjusted System Output '- 14,0376F771,705 1 32,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 1 Jan 12 am /EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26.0 OF 69.8 OF 69.80E .1'16.0 OF Outside Air O: Supply Air Ducts 0 cfm . o Supply Fan Heating Coil 115.8 F 650 cfm ROOMS 70.0 °F 69.8 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICSAirstream Tem eratures at Time of Cooling Peak 111.0177.6 OF 75.4 / 61.6 OF 75.4 ! 61.6 OF 55.1' / 54.0 OF .1 JJW O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil55.5! 54.1 of 650 cfm ROOMS 46.6%° R.H. 75.4/61.6 OF 75.0161.5 OF Return Air Ducts I EnergyPro 3.1 By EnergySoft User Number: 5553 Job' Number: ADY93-1004 Page: 12 of 12