Loading...
11-0687 (RER)P.O. BOX 1504-t -4 Qum' VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 r LA QUINTA, CALIFORNIA 92253 . BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Dater -9/20/11 ' Application Number: 11-00000687 Owner. z Property Address: 57395 VIA VISTA KEITH PIERCE , APN: 762-240-003-30 300962- 57395 VIA VISTA Application description: REMODEL,- RESIDENTIAL LA QUINTA, CA 92253 'Property Zoning: MEDIUM DENSITY RES Application valuation: 175000 ^Contractor:. - • D Applicant: -Architect or Engineer. PADGETT' S CLEANING/RESTORATION E f Co�/Ti2�o�Z• �' � c ; 535 NEW JERSEY STREET _. � t..•,_I r;, 2 2011 { er' �• !.• REDLANDS, CA ,92373 2cc (909)307-2769 _. s CITY OFcq 7 Lic No.: .679028 F?;1+:'S!! til1�q. - •LICENSED.CONTRACTOR'S DECLARATION - , • r „` ,,.. WORKER'S COMPENSATION DECLARATION - .x •,�• '. . I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with .r. I hereby affirm under. penalty of perjury one of the following declarations: Section 7000) of Division. 3 of, the Business and Professionals Code, and my License is in"full force and effect. _ a _ _`� I have and will maintain a ceriificate'of consent to self -insure for workers' compensation, as provided - r License Class: B C15 , License No.: 679028 - - for by Section 3700 of the Labor Code, for the performance of the work for which this permit is i ' _ _ t •' ; issued. �. Date!�ontractor: = I have and will maintain workers' compensation insurance, as required"bySection 3700 of the Labor,, �x • - • . Code, for the performance of the workfor which this permit is issued. My workers' compensation • - OWNER -BUILDER DF ION -insurance carrier and policy number are: - I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier TRAVELERS PROP - - Policy Number DTJUB6155P03110 followings reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to - I certify. that, in the performance of the work for which this permit is issued, I shall not employ any. _ construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the .• person in any manner so as to become subject to the workers' compensation laws of California, .',• - #" permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's, State +' and agree that, if I should become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and ProfessionsCode) or. • - 3700 of the Labor Code I shall o thwit com with those isions. ' that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of. Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:. _ ate: —!�-4 %/Applicant: " (_) I, as.owner of the property, or my employees with wages as their sole compensation, will do the work, and A • F " w - the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code:., The WARNING: FAILURE TO SECUR W RKERS' COMPENSATION COVERA SUNLAWFUL, AND SHALL " • - Contractors'. State License Law does not apply to an owner of property who. builds or improves thereon, . . `SUBJECT.AN EMPLOYER TO CRIMI AL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS (S100,000).. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR -IN _ improvements are not intended or offered for sale. _ If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND;ATTORNEY'S FEES.. one year of completion, the owner -builder will have the burden of proving that he or she did not build or - improve for the purpose of sale.). - - APPLICANT ACKNOWLEDGEMENT" - • "`.' " 1 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project ISec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the - 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of`, conditions and restrictions set forth on this application. • property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed. "1:- Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application,' 1'_ 1 1 am exempt under Sec. B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City, " of La Quinta, its officers, agents and employees for any act or omission related to the work being --- _ - performed under or following issuance of this permit. Date: Owner. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit to cancellation. , I hereby affirm under penalty of perjury that.there is a construction lending agency for the performance of. the I certify that I have read this application and state that the above information is correct. (•agree to comply with all work for which this permit is issued (Sec. 3097, Civ. C.). city and county ordinances and state laws relating to building construction, pd hereby authorize representatives `• - • f thiscounty to enter upon the above-mentioned pr rty for inspectio pu oses. ((.�- Lender's Name: 'Date: �1� ""{I Signature (Applicant or Agent): ' . Lender's Address: - - - LQPERAIIT Application Number . . . 11-00000687 Structure Information Construction Type. TYPE V, UNPROTECTED = Occupancy Type DWELLG/LODGING/CONG <=10 Other struct info '.-,: . . CODE EDITION 2010` # BEDROOMS 2.00 Permit .BUILDING PERMIT Additional'desc,: Q Permit Fee . . 902.00 Plan Check Fee 586.30 Issue Date . . . . Valuation 175000 Expiration. Date 3/18/12 - Qty Unit.Charge Per Ektension ' BASE FEE. 63.9.50' 75.00 3:5000 THOU BLDG 100;001:50'0,000 ', 262.50 Permit" ELECT -.ADD/ALT/REM Additional desc.. ' Permit -Fee 63.97 Plan Check Fee 15:99'. Issue. Date Valuation 0... ; .Expiration -Date." 3/18%12 Qt._ Unit'Charge Per' Extension BASE FEE _. 15.00 1399.00. .0350 - - ELEC NEW RES - 1` -OR .2 FAMILY 48.97 `. Permit MECHANICAL•. desc PermitAditi�Fel e 24 00� Plan Check Fee 6 00 Issue Date Valuation- 0 :Expiration Date x.3/18/12 . Qty Unit -Charge Per Extension"; ASE FEE" 15. 00 2.00 4.SOOq EA MECH VENT'INST/ DUCT ALT 9.00 Permit PLUMBING Additional desc Permit Fee 99.00 P1an.Check Fee 24.75 _ - • Issue Date Valuation 0 . Expiration Date 3/18/12' Qty Unit Charge 'Per Extension LQPER1N11T _ .• Application Number . . . . 11-00000687 Permit . . . . . . PLUMBING Qty Unit Charge Per Extension BASE FEE 15.00 - 9:00 . 6.0000 -EA PLB FIXTURE 54.00- 1.'00. 3.0000 EA.' PLB WATER INST/ALT/REP 3.00 9.00 3.0000 EA PLB FIXTURE DRAIN/VENT-REP/ALT 27.00 --------------------------- Special Notes and Comments _. 'FIRE.RECONSTRUCTION OF SFD. 1399 SF o LIVING 2BR.2BA PER ENGINEERED PLANS.2010 CODES. -- - - - - - - - - - - - - -- - -- - - ------------------------------- Other Fees BLDG STDS ADMIN (SB1473),: ------ ----- -- - - -- - -- 1.00 ENERGY'REVIEW FEE 58.63 STRONG MOTION (SMI).- RES 17.50 Fee 'summary. Charged' Paid _ Credited -Due Permit 'Fee 'Total 1088.97 -.00 .00,`" 1088.97 ' Plan Check Total 633.04 00;- 00 633.04 Other Fee Total 77•.13` .00: 00' 77,.13".. Grande Total- . 1799.14 00 'i :•100.. ..,.1799:14 . LQPER\4IT - ti ►31 `B-� •• �. .. • Ci of La Uinta • City Building 8r SafetrDiv&ion P.O. Box 1504, 78-495 Calie Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit 'Application and Tracking Sheet Permit # ^ Project Address: 3 9f _ / � S/ Owner's Name: � A. P. Number: ��Z �� _ 030 _- C/ Address: Legal Description: City, ST, Zip: �� Q4� ZZSr3 Contractor: 5 - `k M„ Telephone: Project Description: Address: 5 _ _City, ST, Zip: Telephone: :�` •: y�?':£o"`"��:-; .. ��'LJ !7 i ,ems State Lia # : City Lie. #; Arch., Engr. esigner. /Yfi/�Ct � Address: 3 6 Z3 Z G> o G,OE�/ G, � D.� ���i%L�� City, ST, Zip: X Telephone: a p d State Lic. #: �'..��..•` r Name of Contact Person:,�LE �e/,//� its Construction Type: Y Occupancy: ,. 3 Project type (circle one): New Add'n Alter epair Demo Sq. Ft.: J I% 3 # Stories: # Units: % Telephone # of Contact Person: O �i 9 7 S 6 SO Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKE4G PERMIT FEES Plan Sets 3 . Plan Check submitted 10 . Item Amount Structural Calca.Reviewed, ready f orrectioos '? Plan Check Deposit Truss Cates. Called Contact Person %' / Z Plan Check Balance . Title 24 Calcs.o Plans picked up ' Construction Flood plain plan Plans resubmitted Mechanical Grading plan2'! Review, ready for correciionsfissue ectrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading INHOUSE:- '" Review, ready for correctionstiissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees 17117 .14 674 pFclue— 41111su— Stn, Afm* w�i nwy 800-273-1194 _ •. 909-307-2769 • 909-307-2775 (FAX) CA UC# 679028 INSTALLED VENTILATION DUCT SYSTEM INFORMATION Airflows required by the standard refer to delivered airflow of the installed system as determined by testing with a flow hood, flow grid,: or other measuring device Alternatively, the installed equipment's HVL airflow rating at a pressure of 0.25 inch w. c. may be used, the -c provided the- system can be inspected toonfirm -duct sizing meets the prescriptive'requirements of Table 7.1, or manufacturer's duct �+a design criteria - Fan or ' Compliance Required 3 Airflow -' Number of Actual Allowable Pass System Name Method''' Airflow' ;Test°� " .Elbows and Duct Length Duct Length$ or or Location' (T; P; or M) -' '(CFM) '.' _. '1'(CFM), nucte` `Fittin s° (ft) (ft) Fail9 .r .... , ] 4. ',� �,t � h,'• ' ,. ' ? _,:` � syr ,_�• �• ,• 2008 Residential Compliance Forms•August 2009'' ., ,.. 1. Enter the Fan or System Identification Name, 'or Location Name; or System Identifier. •These should be the same identifiers as shown in the INSTALLED VENT/LAT/ON AIR -MOVING EQUIPMENT. INFORMATION table column l above. 2. Enter the method for demonstrating coi;ohance.with the ventilation airflow requirements. Enter ;'T" for Tested,- "P"for Prescriptive Table 7.1 design criteria (inspection); "M"for Manufacturer's duct design criteria (inspection). Note: the building official may require submittal of manufacturer's published designcriteria documentation if compliance is to be demonstrated by inspection of the 3. installation for conformance to manufacturer'stdesigncriteria. determined by the calculations or tables'in 14 WHOLE -BUILDING_ VENTILATION Enter the required ventilation airfloiv_values andlor LOCAL VENTILATION EXHAUST 'sections`at the beginning of this lnstallation Certificate (CFM). These should be the same airflow values that were entered for each corresponding fan rn column 3 of the INSTALLED VENT/LAT/ON A/R -MOVING R 4. EOUIPMENT INFORMATION table above; If complying by a method that requires an Airflow Test of the installed system, enter the "result from the Airflow Test for'the installed 5. system (CFM). Enter duct type for the installed system. Choices.are "Flex" or•"Smooth",if using Table'7.1 for compliance.` 6. Enter total number of elbows or fittings or abrupt turns in the ventilation duct for the installed'systerr% 7. Enter the installed system's` actual total duct length 60): 8. If complying by use of the prescriptive design criteria or manufactw er's design criteria_; .enter the Maximum Allowable Duct Length (ft) for the system as determined by Table 7.1 or manufacturer's duct design criteria '. 9. /f complying by airflow.test, the system passes rf the Tested Airflow' equals or.exceeds the Required Arrflow3. /f complying by • demonstrating conformance to prescriptive: design criteria or_'manufacturer's design criteria, the system passes if actual total duct ' len th' rom column 7 is.les's than the maximum'allawed length from column 8. Enter: Pass or Fail At .r .... , ] 4. ',� �,t � h,'• ' ,. ' ? _,:` � syr ,_�• �• ,• 2008 Residential Compliance Forms•August 2009'' ., ,.. r H BUILDING ENERGY ANALYSIS REPORT" f t s PROJECT: _ Keith Pierce • y ., 57395=V4 Vista . !.,L"a Quinta,: CA 92253 j 4 Project Designer: • MW Designs 1 ,� 36232 Golden Gate Drive - Yucaipa, CA 92399 y z= , •909-289-6504 ..y Report'Prepared. by: 4 Mike Williams,.. ;. 'MW Designs 036232' Goiden Gate Driv C11`Y - - Yucaipa, CA 92399, BIjILp� OF QUIN `. 909-289-6504 N & SAF��. TA A P� pEpT FOR C ROVED TRUC7 45 DAT IIBY. P6 y Job Number. � ::k - � - _ •. z , , - ' ._l:AAA-Pierce-0511 I,Date: .: s R* 8/22/2011 3 1 - The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. ` This program developed by,EnergySoft, LLC—www.energysoft.com.' Energ Pro 5.1 by EnergySoft User Number: 6877 RunCode: 2011-08-22713:58:06 ID: AAA -Pierce -0511 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Keith Pierce Project Address 57395 Via Vista La Quinta Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration California Energy Climate Zon�Total �Cond.oor Area Addition CA Climate Zone 153 n/a Date $/22/2011 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ON o Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features (see Part 2 of 5) Status Wall Wood Framed R-21 134 Ext=R-4.0 Existing Door Opaque Door None 24 New Wall Wood Framed R-15 1,143 Ext --R-4.0 Existing Roof Wood Framed Attic R-30 1,837 Radiant Barrier Venting New Slab Unheated Slab -on -Grade None 1,743 Perim = 167' Existing Wall Wood Framed R-15 212 Ext=R-15.0 Existing Wall Wood Framed R-21 50 Ext=R-8.0 Existing FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status Front (E) 12.0 0.230 0.25 2.0 2.0/2.0 Bug Screen New Front (E) 4.5 0.230 0.25 4.0 4.0/4.0 Bug Screen New Right (N) 27.4 0.230 0.25 5.0 0.0/0.0 Bug Screen New Right (N) 9.6 0.300 0.30 0.0 0.0/0.0 Bug Screen New Right (N) 37.1 0.230 0.25 2.0 2.0/2.0 Bug Screen New Right (N) 22.7 0.310 0.29 10.0 none Bug Screen New Rear (W) 43.0 0.230 0.25 none none Bug Screen New Left (S) 35.0 0.230 0.25 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 97% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Gallons Min. Eff Distribution Status FnPmvPrn 5 1 by FnamvSnff User Number., 6877 RunCode: 2011-08-22T13:58:0 ID: AAA -Pierce -0511 Page 2 of 9 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Keith Pierce Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8/22/2011 SPECIAL FEATURES INSPECTION CHECKLIST` The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-30 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specked in Residential Appendix RA4.2.2. The Roof R-30 Roof Attic 50% of Vents Located High requires verification. _ c - t HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 58MVB40-14 CNP- 38HD 1.5 T, includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC System incorporates HERS. Verified Refrigerant Charge ora Charge Indicator Display. A p EnemyPro 5.1 by EnemySoft User Number. -6877 Run Code: 2011-08-22T13:58:0 /D: AAA -Pierce -0511 Page 3 of 9 PERFORMANCE CERTIFICATE: Residential 1 1 1(Part 3 OT 5) W-1 K Project Name Building Type m Single Family ❑ Addition Alone Date Keith Pierce ❑ Multi Family ❑ Existing+ Addition/Alteration 8/22/2011 ANNUAL ENERGY USE SUMMARY Standard Proposed,. Margin TDV kBtu/ft2 r Space Heating 4.21 3.17.. 1.04 ' Space Cooling 51.35. 49.21, 2.14 ., Fans 10.36 12.62. -2.26 ' Domestic Hot Water 0.00 0.00 0.00 } ` Pumps 0.00 0.00 _ _. 0.00 Totals 65.91 65.00 , ` 0.92,_ Percent Better Than Standard: 1.4% BUILDING COMPLIES':- HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E)90,,deg Ext. Walls/Roof Wall Area Area ` Number of Dwelling Units: ,, 1'00 - - T " (E) ° 436 17 Fuel Available at Site: Natdra/ Gas J: ; • (s) 333 35 "43 Raised Floor Area: 0 M9436 43 s Slab on Grade Area: 'r'1 X43 (N) - 546 97 Average Ceiling Height: 10 5 Root ' 1,837 0 Fenestration Average U-Factor _ 0.24. TOTAL: 191 Average SHGC:- 0.26 Fenestration/CFA Ratio: 11.0% REMARKS 'A STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed " to comply with Title 24, Parts 1 the Administrative ;Regulations and Part 6 the Efficiency Standards of the California Code of.Regulations: The documentation author hereby certifies that the documentation is accurate and completer; Documentation Author Company MW Designs . 8/222011 }N ame , Address 36232 Golden Gate Drive " t Mike Williams - •Cit /State/Zip Yucaipa, CA 92399 Phone 909-289-6504- Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by'an approved'HERS rater., Designer or Owner (per Business &Profession`s"Code)` Company MW Designs Address ,36232 Golden Gate Drive ; Name Mike Williams City/State/Zip Yucaipa, CA 92399 - z ' Phone 909-289-6504 Signed License lF Date A1,­h­ RR77, ` a„mrnriP• 2n•11-08-22T13:58r0 ID: AAA-Pierce-0511 Page 4 of 9 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Keith Pierce Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 8122/2011 OPAQUE SURFACE DETAILS Surface IU T e Area Insulation Joint Appendix Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 134 0.054 R-21 4.0 None 90 90 Existing 4.3.1-A6 Zone 1 Door 24 0.500 None 90 90 New 4.5.1-A4 Zone 1 Wall 344 0.069 R-15 4.0 None 0 90 Existing 4.3.1-A4 Zone 1 Wall 393, 0.069 R-15 4.0 None 270 90 Existing 4.3.1-A4 Zone 1 Wall 2981 0.069 R-15 4.0 None 180 90 Existing 4.3.1-A4 Zone 1 Roof 1,8371 0.031 R-30 180 0 New 4.2.1-A20 Zone 1 , Slab 1,743 0.730 None 0 180 Existing 4.4.7-A1 Zone 1 Wall 212 0.043 R-15 15.0 Wood 90 90 Existing 4.3.1-A4 Zone 1 Wall 50 0.044 R-21 8.0 None 90 90 Existing 4.3.1-A6 Zone 1 Wall 108 0.069 R-15 4.0 None 0 90 Existing 4.3.1-A4 Zone 1 FENESTRATION SURFACE DETAILS 1D Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Window 12.0 0.230 NFRC 0.25 1 NFRC 90 New Milgard DH - 7220 Quiet Line Lc Zone 1 2 Window 4.5 0.230 NFRC 0.25 NFRC 90 New Milgard DH - 7220 Quiet Line Lc Zone 1 3 Window 27.4 0. 2301 NFRC 0.25 1 NFRC 0 New Milgard DH - 7220 Quiet Line Lc Zone 1 4 Window 9.6 0.300 NFRC 0.30 1 NFRC 0 New Milgard Classic Low -E Vinyl Zone 1 5 Window 37.1 0.230 NFRC 0.25 NFRC 0 New Milgard DH - 7220 Quiet Line Lc Zone 1 6 Window 22.7 0.310 NFRC 0.29 NFRC 0 New Jeld Wen Low-EIG Patio Glass Zone 1 7 Window 43.0 0.230 NFRC 0.25 NFRC 270 New Milgard DH - 7220 Quiet Line Lc Zone 1 8 Window 35.0 0.230 NFRC 0.25 NFRC 180 New Milgard DH - 7220 Quiet Line Lc Zone 1 (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID ID Exterior Shade Type SHGC Window Hat Wd Ove hang Left Fin Ri ht Fin Len Hat LExt RExt Dist Len Hat Dist Len Hat 1 Bug Screen 0.76 6.0 2.0 2.0 1.0 2.0 2.0 0.1 2.0 0 0.1 2.0 0 2 Bug Screen 0.76 1.5 3.0 4.0 5.0 1.5 1.5 1.5 4.0 0 1.5 4.0 0 3 Screen 0.76 5.0 6.0 5.0 2.0 3.0 6.0 0.01 0.0 0 0.0 0.0 0 4 Bug Screen 0.76 4.2 2.2 0.0 0.0 0.01 0.0 0.01 0.0 0 0.0 0.0 0 5 Bug Screen 0.76 4.0 10.0 2.0 1.0 2.0 2.0 0.5 2.0 0 0.5 2.0 0 6 Bug Screen 0.76 8.0 2.7 10.0 2.0 2.0 11.0 7 Bug Screen 0.76 8 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6877 Run Code: 2011-08-22T13:58:0 ID: AAA -Pierce -0511 Pa e.5 of 9 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name - Keith Pierce Building Type © Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration I Date 1812212011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered I Removed Volume Year Built HVAC System Zone 1 1,743 18,302 2005 Totals 0 1,743 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Coolinq Type Min. Eff. Thermostat Type Status HVAC System 1 Central Furnace 97% AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION System Name Heating, Duct Coolinq Duct Location R -Value Ducts Tested? Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 8.0 ❑ New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status CEC Standard MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E(ft) E w .2 Hot Water Piping Length o a y a c System Name Pipe Len th Pipe Diameter Insul. Thick. Qt . HP Plenum Outside Buried. 01 ❑ ❑ ❑ ❑ ❑ ❑ ❑ I I 1 11 1 1 1 I u I _ I I I ' MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Date 812212011 Keith Pierce NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (`), below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -.1 R ` Form with plans. Building Envelope. Measures: 4 116(a)l: Doors and windows between conditioned and unconditioned s aces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of §10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulation secified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the y` installation of a Cool Roof is specified on the CF -1 R Form.` *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor' 150(b): Loose fill insulation shall conform with' manufacturer's installed design labeled R -Value. ' *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. ' *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when's ecified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. - §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Aolpliances and Gas Log Measures: " 150 e 1 A: Masonry or facto -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air.intake, which is•at least six square inches in area and is equipped with a with a readily accessible, operable, and ti ht-fittin 'dam per and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. . Sp ace Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment,,water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy y Commission. • ` , ` - §113(c)5: Water heating recirculation loops -serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. �. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are aqui I pped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R=16 internal insulation where the internal insulation'R-value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of .: recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and -Equation 150-A:. ' §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table r 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance and wind. §150(j)3A: Insulation for•chilled water piping and refrigerant suction lines includes a vapor retardant oris enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. - MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Date 812212011 Keith Pierce NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (`), below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -.1 R ` Form with plans. Building Envelope. Measures: 4 116(a)l: Doors and windows between conditioned and unconditioned s aces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of §10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulation secified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the y` installation of a Cool Roof is specified on the CF -1 R Form.` *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor' 150(b): Loose fill insulation shall conform with' manufacturer's installed design labeled R -Value. ' *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. ' *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when's ecified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. - §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Aolpliances and Gas Log Measures: " 150 e 1 A: Masonry or facto -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air.intake, which is•at least six square inches in area and is equipped with a with a readily accessible, operable, and ti ht-fittin 'dam per and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. . Sp ace Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment,,water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy y Commission. • ` , ` - §113(c)5: Water heating recirculation loops -serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. �. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are aqui I pped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R=16 internal insulation where the internal insulation'R-value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of .: recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and -Equation 150-A:. ' §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. , 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance and wind. §150(j)3A: Insulation for•chilled water piping and refrigerant suction lines includes a vapor retardant oris enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. - EnergyPro 5.1 by EnergySoft User Number. 6877 ' = Run Code: 2011-08-22713:58:06 ID: AAA -Pierce -0511' Page 7 of 9 • _;. •vt. .. 1, •- " � Y` •• �- � ��, {'A •.. Y •-++ �` ` r ` MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 mr--i K Project Name Date 8/22/2011 Keith Pierce §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604,'605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool'or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or -built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizin , flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no -lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150 (k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d), §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. FnumvPm .5 1 by FnamvSnft User Number: 6877 RunCode: 2011-08-22713:58:06 /D: AAA -Pierce -0511 Page 8 of 9 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 atF-1 R Project Name Date 8/22/2011 Keith Pierce §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters laboratory; have a label that certifies the lumiunaire is airtight with air Laboratories or other nationally recognized testing/rating and leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more *the dwelling units, entrances, balconies, and. porches, which are permanently mounted to a residential building or to other buildings on same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 maybe controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be hi h efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131,.134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 4119. EnergyPro 5.1 by EnergySoft User Number: 6877 RunCode: 2011-08-22T13:58:06 /D: AAA -Pierce -0511 Page 9 of 9 home Projects ► CF -1R Registration / My Builders My Energy Consultants My Installers ID Name Uploaded CEC Builder Status Merge Request My Signature By Registration- - To Print Sign -Off 170684 Keith Pierce 92253 -Mike Williamsx 211-N0043481A Preview Upload File`: " Open Reports If you are having trouble uploading a plan, ,you can try and preview upload the file here. Note that ._• " My Raters , View/Pay Invoice Training Schedule My Signature Agreements - My Info Customer Info Preview Upload File`: " Reports If you are having trouble uploading a plan, ,you can try and preview upload the file here. Note that " Compliance uploading it with this method will NOT store it on our, server. This is a simple tool to verify your upload Forms Energy Calculation file is valid: Website Updates File To Upload;77 F7777 Browse View,File > Log Out " Copyright © 2010 CaICERTS, Inc. All rights reserved. CaICERTS, Inc. Revised: January 11,; 2010M �w/ 1-, �Ir 31 Natoma St Suite 120 [Terms and Conditions] Folsom, CA 95630 [Privacy Statement] Designs Office: 916-985-3400 . [Class Cancellation Policy], Toll Free: 877-HERS-R8R (877-437-7787) ' Fax: 916-985-3402 Contact Us ht.tn //www ralclPrtc r^.nm%Mane (Nn 1%r 0. PI7