BRES2016-0227:, � j■cam l
78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 C` 0 U '` Q�-
I' cl/ .. VOICE (760) 777-7125
FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
4
• +' � Date: 3/6/2017:
Application Number: BRES2016-0227 Owner:
Property.Address: 79030 VICTORIA DR Z�JDCELIA ARELLANO
APN: L- 604371018 MAR 0-g 79030 VICTORIA DR
Application Description: REMODEL ADDITION/ CELIA ARELLANO 2017 LA QUINTA; CA 92,253
Property Zoning: .
Application Valuation: ' $25,000.00 DESIGNAND 11 OFA QU/NT
Applicant: EV �COPM�NT 06PARr Contractor:
GABRIEL LUJAN MFNT OWNER /BUILDER
36947 COOK ST STE 104
.PALM DESERT, CA 92221-1
Llc. No.: ,
LICENSED CONTRACTOR'S DECLARATION " WORKER'S COMPENSATION DECLARATION
I hereby affirm underpenalty'of perjury that I am licensed under provisions of Chapter I hereby affirm under penalty of perjury one of the following declarations:
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, I have and will maintain a certificate of consent to self -insure for workers'
and my License is in full force and effect. compensation, as provided for by Section 3700 of the Labor Code, for the performance
License Class; _ License No.: _ of the work for which this permit is issued. ,
I have and will maintain workers' compensation insurance, as required by
Date: Contractor: Section 3700 of the Labor Code, -for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
OWNER -BUILDER DECLARATION carrier: Policy Number:
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State �ertify that in the performance of the work for which this permit is issued, I
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any' shall not employ any person in any manner so as to become.subject to the workers'
city or county that requires a permit to construct, alter, improve, demolish, or repair compensation laws of California, and agree that, if I should become subject to the
th
any structure, prior to its issuance, also requires e applicant for the permit to file a workers.' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
signed statement that he or she is licensed pursuant to the provisions of the comply with those provisions.
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the. Date: - Applicant:,, ll/ ti
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for e
permit subjects the applicant to a civil penalty of not more than five hundred dollars WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS.UNLAWFUL,
(S500).: AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES -AND CIVIL FINES UP TO
y'l, as owner of the property, or my employees with wages as their sole , ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COSTOF,
compensation, will do the work, and the structure is not intended or offered for sale. COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not INTEREST, AND ATTORNEY'S FEES.
apply to an owner of property who builds or improves thereon, and who does the work
%himself or herself through his or her own employees, provided that the improvements APPLICANT ACKNOWLEDGEMENT ,
are not intended or offered for sale. If, however, the building or improvement is sold IMPORTANT: Application is hereby made to the Building Official for a permit subject to
within one year of completion,,the owner -builder will have the burden of proving that, the conditions and restrictions set forth on this application.
bq or she did not build or improve for the purpose of sale.). 1.' Each person upon'whose behalf this.application is made, each person at whose
I, as owner of the property, am exclusively contracting with licensed contractors ' request and for whose benefit work is performed under or�pursuant ,to any permit
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors: issued as a result of this application , the owner, and the applicant, each agrees to, and
State License Law does not apply to an owner of property who builds or improves shall defend, indemnify and hold harmless the City of.La Quinta, its officers, agents, and
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to employees for any act or omission related to the work being performed under or
"Contractors' State License Law.). following issuance of this permit.
I am exempt under Sec. B.&P.C. for this reason 2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
- work for 180 days will subject permit to cancellation.
`Date: Owners=�._ d
I certify that I have read this application and state that the above information is correct.
CONSTRUCTION LENDING AGENCY I agree to comply with all city and county ordinances and state laws relating to building
1 hereby affirm under penalty of perjury that there is a construction lending agency for, construction, and hereby authorize representatives of this city to enter uponthe,
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). above-mentioned property for inspection purposes.
Lender's Name: C" Date: Signature (Applicant orAge'nt) 41 y
f • i
Lender's Address:
DESCRIPTION ACCOUNT QTY AMOUNT
ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83
DESCRIPTION ACCOUNT QTY AMOUNT
ADDITION, FIRST 100 SF PC 101-0000-42600 0 $171.14
Total Paid for ADDITION: $291.97
DESCRIPTION
ACCOUNT •
.QTY
AMOUNT
QTY
BSAS SB1473 FEE
101-0000-20306
0
$1,00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$145.03
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$47.86
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89
DESCRIPTION
ACCOUNT
QTY
AMOUNT
CONDENSER/COMPRESSOR
101-0000-42402 '
0
$36.26
DESCRIPTION
ACCOUNT
QTY
AMOUNT
CONDENSER/COMPRESSOR PC
101-0000-42600.
0
$24.17
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FURNACE
101-0000-42402 `
0
$36.26
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FURNACE PC
101-0000-42600
0
$24.17
DESCRIPTION
ACCOUNT
QTY
AMOUNT
VENT FAN
101-0000-42402
0 •
$12.09
DESCRIPTION
ACCOUNT
QTY
AMOUNT
VENT FAN PC
101-0000-42600
0
$4.83
Total Paid for MECHANICAL: $137.78
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$60.45
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$60.45
DESCRIPTION
ACCOUNT
QTY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS
101-0000=42401
0
$12.09
DESCRIPTION
ACCOUNT.'
QTY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS PC
101-0000-42600
0
$24.17
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$12.09
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$12.09
Total Paid for PLUMBING FEES: $181.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
a
t ,
4 . • t , � .Jr . ,_gin • : f ... - + , . ' 1-• + ' .
n1 REMODEL;, EA ADDITIONAL 500 SF
, . 101-0000-42400.4 .1
0
$21.75
.• DESCRIPTION
ACCOUNT,
QTY -
AMOUNT
REMODEL, EA ADDITIONAL 500 SF PC
�. 101-0000-42600 , '
0.' .
$17.40
'DESCRIPTION
' _ r ACCOUNT ..
QTY
AMOUNT
REMODEL, FIRST 100 SF
101-0000-4240.0 r'
0
$49.31
DES CRI PTIONx
ACCOUNT
r'QTY
AMOUNT
REMODEL, FIRST 500 SF PC
101-0000-42600 �,
0
:$134.88 '
Total Paid for REMODEL: - $223.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SMI -RESIDENTIAL .
101-0000-20308
0'
a
Total Peid for'STRONG.M_ OTION INSTRUMENTATION SMI: $3.25'
t,
s
71
•�
s
r
.1 _ ,
;` ��
'.
�. �" 'fir'
•
z.
�
�.,
�
-.
�
!,' i
,.f t �c,
j. +`. n7i
�,q
•. �
t
/ '
r'• �
r !.
t .1,
. �
� � y�f,. -C r `.Fx,
f •ice#'
' Y
�
•
Bin # City of La Quihta
..... .................... ...... Building &I Safety Division
Permit #1 . 78-495 Cale Tampico
La Quinta, CA 92253 - (760) 777-7012
S}kja Building Permit Application and Tracking Sheet
Project Ad i ess C a ,» Owner's Name:
10, r1p
A. P. Number:
Addmssi
Legal I�escnj�iton
CityST, Zip:
Contractor
\
TGluphtiiid _
�r��
Address: a
Project Description: `
City, ST Zip:
✓,� .l. :'
Telephone:
.
?�.
State I i n _
City Lie if ..-.
Arcn. Engr, signer: `
Address C� �L
..
t .. ...:::.. .. .. ... .:-......
City, ST Zip;:._
.. ..
Telephone:
StateLic.y ._
. :
fxr.
pe V Occupane} :.Q�
Construction Ty
'
Project type (circleon New dd n Iter_ Rep air _ Demo.
Name of Contact Person.4
CYC ..
Sq. Ft!.,
,1 Stones ;
# Units
Telephone #. of Contact Person; . j
Estimated Value of Fro+ect: 0M P
._..,..,.,APPLICANT: DO NOT WRITE BELOW THIS LINE
p
Submittal '
` Req'd .:
Rec'd
TRACICING..... ., . ....
__PERMITFEES•.
Plan Sets
Plan Check submitted-,;
Item
Amount..
Structural Cates.
Reviewed, ready for corrections '
',
Plan Check Deposit
,.
Truss
Truss Calcs
Called Contact Person
Plan Check Balance
Title 24 Cales.
Plans picked up
Construction
F1od plain plan.
t
Plans resubmitted
Mechanical
Grading plan
3
2nd Review, ready for corrections/issue
Electrical
k
-'
Subcontactor List
Called Contact Person
Plumbing
Grant DecdPlans,
picked up =
: S.A1.I.
__ ...
II.O.A. Approval
Pians resubmitted
Grading
IN IIOUSF
' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.LP.P
Pub. Wks. Appr
Date of permit issue
-
•
Scit0ol 11
:Total Permit Fees
CERTIFICATE OF:COMPLIANCE J��FrEc s
Desert Sands Unified School Districtcyo
47950 Dune Palms Road. M°'o
INDIAN WECLSS
a:PALMD -1Lag y
Le Quints CA 92253=COACMELLA,' a
NO.Date1'7 00503 17. (760)77185:15.vot?N01Nrn
- Inolo4,y4
a.
Owner: CELIA A'RELLANO ; • Email:"
Address: 79030 VICTORIA DR Jurisdiction: La Quints
City: La Quinta, CA Tract.#
Type: Residential Addition <:500 sq ft
Lot # . Street.No. Street.Name Sq. Feet , . APN° Permit No..
79030 VICTORIA DR 325 604-371-018
Comments:
At the :present time, the Desert Sands Unified School District does not collect fees on garages/carports; covered ,patios/walkways, residential additions
under 500 square feet, detached accessory structures. (spaces that do not contain'facilities for living', sleeping,. cooking eating, or sanitation).or replaceme.;t
mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
- . Residential Addition 500 Sq Feet or Less
Exempt
'This certifies that school facility.fess imposed. pursuant to
Education Code.Section 17620.and Government. Code 65995.Et Seq.
in the' amount of -.$0.00 X'.325'S.F. or $0.00 have been paid.for tiie pro pertylisted above and that building permits
an'd/or*Certificates of Occupancy for this square footage, in the proposed project may now be issued.
Fees Paid- Byc Exempt\Celia Arellano" Check No.
Bank Name/Recipient of Certificate Telephone 760=578-4960
.Funding:. Exempt
By Kathleen Felci
Interim Superintendent.
t
Fee Collected/ Exempted by: ; V' ilio ci Certificate Fees Oue:'A.0.00
. L�
Original Payments R-c'd: SO'MO �r
New Paymerit;Pec'd: �0�00 I 'C• A
Over/�iJndPr: <$0 00 r
NOTICE: Pursuant to Govemmerit Code Section 66020 this wi serve to notify you that the 90-da approval erlod in:which you may mte�stj�hi
� Y PP P y Y p,.
other payment identified above will begin to run from the date on ' ich the building or installation permit.for this 'project is.issued; or from Mh date on .
which• those amounts 'are-paid to the:District(s) or to another public ent authorized tb�collect them on the District('s) behalf, whichever is earlier."
Noticeto Building Department: THIS DOCUMENT VALID ONLYIF.IMPRINTED WITH EMBOSSED.SEAL.
P.O. Box 1504
LA QUIN:TA, CALIFORNIA 92247' -1504 -.BUILDING &'SAFETY DEPARTMENT -
G`� of 94`' 78-4.9.5 CALLS TAMPICo• (760) 777-7012 .
LA QUINTA,CALIFORNIA 92253 FAX (760)777-7011
PROPERTY OWNER'S PACKAGE
• ,:r!
Disclosures & Forms :for Owner -Builders Applying for Constructioa Permits
IMPORTANT! 'NOTICE TO PROPERTY OWNER-
Dear
WNERDear Property Owner:
An. application `for ,a building s be submn a un, our name listing .yourself as the. builder,- of the property
improvements specified atll�
We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your
responsibilities:and possible risk you rmay,incur by having this permit:issued.in your name as the .
Owner -Builder. We will not issue a building.pertrut until you -have read, initialed your understandingof each provision,'
signed,and returned this form to •us at our official address indicated.'Anagent of the owner .cannot execute this notice
unless you, the property owner,. obtain the prior approval of the permitting authority:
OWNER'S ACKNOWLEDGMENT AND. VERIFICATION OF INFORMATION
DIREGTJONS. Read and initial each statement below to signsyou. understand.or verify his information, '
1. I .unders d a frequent` practice of unlicensed persons is .to have the',property owner, obtain an"Owner-Budder"
building permit that eri•oneously•implies that the property owner is providing his; or. her own labor and material -pe
rsonafiy.`l1'as
an Owner -Builder; maybe,held'liable and 'subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those
injuries. I am willfully acting as an Owner -Builder and am aware of the limits'of my insurance coverage for injuries to workers
on my property.
(2. I understand building permits are not required to be _signed', by property owners unless they, are responsible for the R
construction and are not hiring a licensed Contractor to assume this- responsibility:
�3. I understand as an :".Owner -Budder" I am tiie resrisible
po party of record on the permit I understand that I may protect
myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name'instead of my
own.
e
�4. I understand Contractors are requiredby law to be licensed and bonded in California and to list their license numbers on
permits and contracts.
5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value
of.my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an ".employer"
under state and federal law.
1 understand if I am considered an "employer" understate and-federallaw, I must register with the state and federal
government, withhold payroll taxes, provide workers' compensation disability insurance; and .contribute to unemployment
compensation for each "employee." I also understand my failure to: abide by these law 'may subject me. to aerious financial
,
7- 1 understand under California Contractors' State.License Law, an OwnerBuilder who builds single7fa m'ily residential
structures cannot legally .build them with :the . intent to offer them for sale; unless' all work is performed by licensed
subcontractors and the number of structures does nor exceed four within any calendar, year, or .all of the work is performed
under contract with a licensed general building Contractor.
8. I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any
financial or personal injuries 'su'stained by any subsequent owner(s) that result from any latent construction defects in the
workmanship or materials.
9. I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue
Service, the United States Small.Business Administration, the California Department of Benefit Payments, and the California
Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-
800-321-CSLB (2752) or www.tsib.ca.gov for more information about licensed contractors.
10. 1 am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the
party legally, and financially responsible for proposed construction activity at the following address:
11. I agree that, as the party legally and fmancially responsible for this proposed construction activity, I will abide by all
applicable laws and requirements that govern Owner -Builders asmell as employers.
12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I
have .provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with
someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss
you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors `may be in civil court. It is also
important for you to understand that if an unlicensed Contractor or employee of that individual' or firm is injured while working
on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and. wish to hire Contractors,
you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers'
compensation insurance coverage..
Before a building permit can be issued, this form must be completed and signed by the property owner and returned to
the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or
other verification acceptable to the agency is required to be presented when the permit is issued to verify the property
owner's signature.
Signature of property owner ��o0 Date:,03/0
Note: The following Authorization Form is required to be completed by the property owner only when designating
an agent of the property owner to apply for a construction permit for the Owner -Builder.
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is.my personal responsibility, I hereby authorize
the following person(s) to act as my agent(s) to apply for, sign, and file. the documents necessary to obtain an Owner -Builder
Permit for my project.
Scope of Construction Project (or Description of Work):
Project Location or Address:
Name of Authorized Agent:
Address of Authorized Agent:
Tel No
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above
information and certify its accuracy. Note: A copy of the.owner's driver's license, form notarization, or other verification
acceptable to the agency is required to be present d whe t e permit is issued. to verify the pro erty owner s signature.
Property Owner's Signature'
Date: U,E;
BUILDING ENERGYANALYSIS .REPO
CITY OF LA QFF
UANTA
BUILDING &SAFETY DEPT. PROJECT:
APPROVED s
FOR CONSTRU TION
Ors. Celia Arellano
79030 Victoria Dr.
DATE BY Quinta, Ca ,92253
h Project Designer:
GABRIEL LUJAN & ASSOCIATES N
36947 Cook St. Suite 104
1 Palm Desert, Ca -T
*° (760) 578-8545
Report Prepared
f.
Santiago Lopez-Ocampo
{ Santiago Lopez=Ocampo
P.O. Box 1018
R i La Quinta, Ca 92247 x.
- • 760.485.8927 7
HEC 1 F
< - Job Number:. FEB 0 7..2017 i
LQ080216 - Rev121316 T
CITY OF LA Qi11PfTA
• COMMUNITY OEVELPPMENT
Date:
' A •.. .12/.13/2016
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the Califomia Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 6.7rEnerg Soft User Number: 5732 ID: LQ080216 - Rev1213
EnergyPro 6.7 by EnergySoft Job Number. ID: LQ080216 - Rev121316 User Number: 5732 r
CERTIFICATE OF COMPLIANCE - RESID?1TIALPERFORMANCE COMPLIANCE METHOD~ CF1R-PRF-01• �~
Project Name: Mrs. Celia Arellano Calculation Date/Time: 13:25, Tue, Dec 13, 2016. Page 1 of 6
Calculation Description: Title 24 Analysis Input File Name: Mrs. Celia Arellano - 79030 Victoria Dr. Rev121316.xm1
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name Mrs. Celia Arellano
04
05
02
Calculation Description Title 24 Analysis
08.
Energy Use (kTDV/ftZ-yr)
03
Project Location 79030 Victoria Dr.
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 180
12
Project Scope Newly Constructed (Addition Alone)
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2) 335
15
Number of Zones 1
16
Slab Area (ft) 335
17
Number of Stories 1
18
Addition Cond. Floor Area 0
19
Natural Gas Available Yes
20
Addition Slab Area (ft) 0
21
Glazing Percentage (%) 8.4%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification,
03 This building incorporates one or more Special Features shown below
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
Registration.Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744
HERS Provider:
Report Generated at: 2016-12-13 13:25:36
ENERGY USE SUMMARY
04
05
06
07
08.
Energy Use (kTDV/ftZ-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
5.13
3.68
.1.45
28.3%
Space Cooling
134.19
122.18
12.01
8.9%
IAQ Ventilation
2.45
2.45
0.00
0.0%
Water Heating
50.42
54.65
-4.23
-8.4%
Photovoltaic Offset
—
0.00 '
0.00
--
Compliance Energy Total
192.19
182.96
9.23
4.8%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
Registration.Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744
HERS Provider:
Report Generated at: 2016-12-13 13:25:36
_OMPLIAN
^_RTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE:CE METHODS"'
- . . Project Name: Mrs. Celia Arellano Calculation Date/Time: 13:25,.Tue, Dec 13 2016
Calculation Description: Title 24 Analysis Input File Name: Mrs. Celia Arellano 79030 Victoria Dr. Rev121316.xm1
x
CF1 R -PRF -01
Page 2 of 6
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
— None —
Cooling System Verifications:
—VANone --
HC Distribution System Verifications:
— None —
Domestic Hot Water System Verifications:
— None — `
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use E 9yDesign`Ratin
g� Margin Percent Improvement
BUILDING- FEATURES INFORMATION
Total Energy (kTDVlf2-yr)* 246.42
02
03
9.23
3.7%
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
includes calculated Appliances and Miscellaneous Energy Use (AMEU)
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Mrs. Celia Arellano
BUILDING- FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Mrs. Celia Arellano
335
1
1
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
ADDITION
Conditioned
HVAC Systeml
335
8
DHW Sys 1
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards. -,2013 Residential Compliance Report Version - CF1R-04072016-744 j ' Report Generated at: 2016-12-13 13:25:36 .
_)ANCEr RESIDENTIAL.PERFORMANCE COMPLIANCE METHOC•a 's -:P1R-PRF-01
CERTIFICATE OF,COMF'
S
Project Name: Mrs. Celia Arellano Calculation Date/Time: 13:25, Tue, Dec 13, 2016 Page 3 of 6
Calculation Description: Title 24 Analysis Input File Name: Mrs. Celia Arellano - 79030 Victoria Dr. Rev121316.xm1
OPAQUE SURFACES
04 02 03 04 05 06 07 08
Name 'Zone' Construction Azimuth Orientation Gross Area (W) Window & Door Area (ftZ) Tilt (deg)
Ri/E ADDITION R-13 Wall 0 Back 163.3 20 90'
Le/W.ADDITION R-13 Wall 0 Back 120 01 90
Le/W 2 ADDITION R-13 Wall' 270 Left 43.3 0 90
Fr/S ADDITION R-13 Wall 180 Front 57.3 4 90
Fr/S 2 ADDITION R-13 Wall 180 Front 89.3 24 90
Roof 2 ADDITION R-38 Roof Attic 228
OPAQUE SURFACES — Cathedral Ceilings
01 02 03 04 05 06 07 08 09 10 11
Orientatio Skylight Area Roof Rise Roof ' Roof Tilt Roof Roof Framing
Name Zone Type n Area (ftZ) (M)) (xi n 12)• Pitch (deg) Reflectance Emittance • Factor
Roof ADDITION R-38 Roof Rafter Back 107 0 0 - 0 0 0.1 0.85 0.1
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emiftance Radiant Barrier Cool Roof
Attic ADDITION Attic RoofADDITION Ventilated 0 0.1 0.85 No No
WINDOWS
01 02 03 04 05 06 07 08 09 10
Multipli Area
Name . Type Surface (Orientation -Azimuth) Width (ft) Height (ft) er (ftZ) U -factor SHGC Exterior Shading
4010 XO Bath Window Fr/S (Front -180) -- -- 1 4.0 0.51 0.37 Insect Screen (default)
6040 XO Guest House Window Fr/S 2 (Front -180) --. - — 1 24.0 0.51 0.37 Insect Screen (default)
3068
OPAQUE SURFACES — Cathedral Ceilings
01 02 03 04 05 06 07 08 09 10 11
Orientatio Skylight Area Roof Rise Roof ' Roof Tilt Roof Roof Framing
Name Zone Type n Area (ftZ) (M)) (xi n 12)• Pitch (deg) Reflectance Emittance • Factor
Roof ADDITION R-38 Roof Rafter Back 107 0 0 - 0 0 0.1 0.85 0.1
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emiftance Radiant Barrier Cool Roof
Attic ADDITION Attic RoofADDITION Ventilated 0 0.1 0.85 No No
WINDOWS
01 02 03 04 05 06 07 08 09 10
Multipli Area
Name . Type Surface (Orientation -Azimuth) Width (ft) Height (ft) er (ftZ) U -factor SHGC Exterior Shading
4010 XO Bath Window Fr/S (Front -180) -- -- 1 4.0 0.51 0.37 Insect Screen (default)
6040 XO Guest House Window Fr/S 2 (Front -180) --. - — 1 24.0 0.51 0.37 Insect Screen (default)
3068
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emiftance Radiant Barrier Cool Roof
Attic ADDITION Attic RoofADDITION Ventilated 0 0.1 0.85 No No
WINDOWS
01 02 03 04 05 06 07 08 09 10
Multipli Area
Name . Type Surface (Orientation -Azimuth) Width (ft) Height (ft) er (ftZ) U -factor SHGC Exterior Shading
4010 XO Bath Window Fr/S (Front -180) -- -- 1 4.0 0.51 0.37 Insect Screen (default)
6040 XO Guest House Window Fr/S 2 (Front -180) --. - — 1 24.0 0.51 0.37 Insect Screen (default)
3068
DOORS
01 02 : 03 04'
Name Side of Building Area (W) U -factor
• Ri/E 20.0. 0.50
Registration Number Registration Date/Time: ,, ,',;, HERS Provider:,
CA Building Energy Efficiency` Standards - 2013 Residential Compliance - Report Version - CF1R-04072016-744 Report Generated at: 2016-12-13 13:25:36
3068
Registration Number Registration Date/Time: ,, ,',;, HERS Provider:,
CA Building Energy Efficiency` Standards - 2013 Residential Compliance - Report Version - CF1R-04072016-744 Report Generated at: 2016-12-13 13:25:36
CERTIFICATE OF COMPLIANCE RESIDENTIAL PERFORMANCE COMPLIANCE METHOD . , ,: = ' " � CF1R-PRF-01 _
Project Name: Mrs. Celia Arellano. `'t Calculation Date/Ti 13:25, Tue, Dec 13; 2016 Page 4 of 6
Calculation Description: Title 24 Analysis. ' �• Input File Name: Mrs. Celia Arellano - 79030 Victoria Dr.=Rev121316.xm1
r•
0
OPAQUE SURFACE. CONSTRUCTIONS
01
02
03
04
05,-
06
07
02
-
04
,
Total Cavity
Winter Design
Name
Construction Name
Surface Type
Construction Type
Framing
_ - R -value
U -value
Assembly Layers
ADDITION
228
0.1
-
0.8
No
Cavity/Frame: no insul. /2x4 Top Chrd
-
107
0.1
None
_
-
Roof Deck: Wood Siding/sheathing/decking
2x4 Top Chord of Roof Truss @ 24
• . Tile Gap: present
Attic RoofADDITION
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.400
Roofing: 10 PSF (RoofTile)
• Inside Finish: Gypsum•Board
• Cavity / Frame: R-13 / 2x4.
-
Exterior Finish: Wood
R-13 Wall.
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
'0.095
Siding/sheathing/decking
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/ Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
•
Inside Finish: Gypsum Board
r Cavity / Frame: R-38 / 2x 12
'
Roof Deck: Wood Siding/sheathing/decking
R-38 Roof Rafter
Cathedral Ceilings
Wood Framed Ceiling
2x12 @ 16 in. O.C.
R 38
0.030
Roofing: Light Roof (Asphalt Shingle)
SLAB FLOORS,
01
02
03 -
04
05
06
-07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R -value & Depth
Carpeted, Fraction
Heated
Slab -on -Grade
ADDITION
228
0.1
None
0.8
No
Slab -on -Grade 2
ADDITION
107
0.1
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION '
01 02. 03 04
Quality Insulation Installation (QII). Quality Installation of Spray Foam.lnsulation Building Envelope Air Leakage; CFM50
Not'Required • Not Required '4 Not Required -_
WATER HEATING SYSTEMS
01 02 03 = _04 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction I%)
DHW Sys 1 - 1/1 DHW Standard DHW Heater 1 1 .0%
Y Lr r ■ T
CER rlCATE OF COMPLIANCE -m RESIDENTIAL.. PERFORMANCE COIL rUANCE METHOD f - < `,, r wu, CF1R-PRF-01 "
Project Name: Mrs. Celia Arellano"_ CalculationDate/Time 13:25 Tue; Dec 13, 2016 "; #� �, Page 5 of 6
Calculation= Description:'Title N Analysis .. Input File Name: Mrs. Celia Arellano - 79030 Victoria Dr. Rev121316.xm1
WATER HEATERS
01
01' . - -
02 _
03 _ .
04
05'06
07
07
08
-. :.
:.
•-
Recirculation
Control
Central DHW
Distribution
DHW.Sys 1 - 1/1
Tank Exterior
--
--
—
--
- Tank Volume
Energy, Factor or
•DuctlessHeatPump
Insulation
Standby Loss '
Name
Heater Element Type
Tank Type
(gal)
Efficiency .
Input Rating
R -value
(Fraction)
r, DHW Heater 1
Natural Gas
Small Storage ►
50. "
0.575.. -
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION G
01
02
•03
04
05
06
07
Name
"Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW.Sys 1 - 1/1
--
--
--
—
--
--
SPACE CONDITIONING SYSTEMS. - -
01
02'
03-
04
05
06
SC Sys Name
System Type '
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
'
:Heat Pump System 1:::2
_
Heat Pump Heating and
Cooling System.-
Heat Pump System 1
Heat Pump System t �
�
`None" -
- None `
HVAC - HEAT PUMPS -
01
02..
03 04 05
06 07
08
09
10
' y
-
-
Heating
Cooling - ._
Zonally
Multispeed
HERS
Name
Type .:
HSPF/COP 'Cap 47 Cap 17
SEER EER
Controlled
Compressor`
Verification
-Heat Pump System 1:
•DuctlessHeatPump
? 9.2
17000
12600
-77f'-7-
14
12
No
No' "
Heat Pump System
a .
1 -hers -cool
HVAC COOLING- HERS VERIFICATION.
01
02 •
_ 03 .
04
05
06
Name
.
Verified Airflow
, .
Airflow Target
_ ` ` Verified EER„
Verified SEER
Verified t n
ed Refrigera
Charge
Heat Pump System 1 -hers -cool
Not Required
--
Not Required
Not Required
Not Required
h
CERTIFICATE OF COMPLIAI" _E - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD 4 {: CFI - PRF -01,
Project Name: Mrs. Celia Arellano Calculation Date/Time: 13:25, Tue, Dec 13, 2016 Page 6 of 6
Calculation Description: Title 24 Analysis Input File Name: Mrs. Celia Arellano -79030 Victoria Dr. Rev121316.xm1 -
DOCUMENTATION AUTHOR'S DECLARATION.STATEMENT '
1. 1 certify that this Certificate of Compliance documentation is accurate and complete. ,
Documentation Author Name:
Documentation Author Signature: `
Santiago Lopez-Ocampo
Company: _
Signature Date:
Santiago. Lopez-Ocampo
12/13/2016
Address:
CEA/HERS Certification Identification (If applicable):
P.O. Box 1018
'
City/StatZip:
Ta Quinta, Ca 92247
Phone: '
760.485.8927•
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under _the laws of the State of California:
1. • I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of.
- Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent v✓ nformation provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this b ding permit application.
Responsible Designer Name:
Responsible De ' nure:
Company:
Date Signed:
GABRIEL LUJAN & ASSOCIATES
Address:
License:
36947 Cook St. Suite 104
City/State/Zip,
Phone:
Palm Desert, Ca
(760) 578-8545
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Mrs. Celia Arellano
Building Type m Single Family m Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
12/13/2016
Project Address
79030 Victoria Dr. La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
335
Addition
0
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features Status
Slab Unheated Slab-on-Grade no insulation 335 Perim = 0' ; " Existing
Wall Wood Framed R 13 - 333 Existing
Door Opaque Door - no insulation 20 New
Wall Wood Framed R 13 173 1 New
Wall Wood Framed R 13 65. Altered
Roof Wood Framed Attic R 38 228 Altered
Roof Wood Framed Rafter R 38 107 Altered
FENESTRATION Total Area: 28FGlazing Percenta e: 8.4 % New/Altered Average U-Factor: 0.51
Orientation Area(ft) U-Fac SHGC Overhang.Sidefins Exterior Shades Status
Front (S) 28.0 0.510
0.37 none none Bug Screen New '
HVAC. SYSTEMS
Qty. Heating Min. Eff
Cooling' Min. Eff Thermostat Status
1 Split Heat Pump 9.20 HSPF
Split Heat Pump 14.0 SEER Setback '
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
HVAC System Ductless /with Fan
Ductless n/a n/a
New
WATER HEATING
QtY. TY0e Gallons Min. Eff Distribution Status
EnergyPro 6.7 by EnemySoft User Number. 5732
RunCode: 2016-12-13T13:26:25 ID: LQ080216 - Rev1213 Pa e 9 of 14
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information.
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of §10-11 1(a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110 8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of cool roof is specified on the CFI R.
§110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ I50.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ I50.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§I50.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
§I50.0(g)1:
In Climate Zones 14 and 16 a Class Il vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
walls, vented attics and unvented attics with air -permeable insulation.
§ 150.0(g)2:
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
150.0 (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e) I A:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e) I B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§I50.0(e)IC:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ I50.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§I 10.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§I50.0(h)1:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§I50.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§ 150.00)1 A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150.OQ)1 B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ I50.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§I50.00)2C:
Pipe for cooling system lines shall be insulated as specified in §I50.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§I50.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3 B:
or Class 11 vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§I50.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5.
§I50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSUSMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ I50.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seat openings greater than '/4 inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ I50.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction: duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ 150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§I50.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ 150.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ I50.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§I50.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§ 150.0(m)13:
space conditioning system must also demonstrate airflow? 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ 150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ I50.0(o):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§I50.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 1 10.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§110.4(b)l :
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 1 10.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 1 10.4(b)3:
pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.
§110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ I50.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§1 10.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §110.9.
§ I50.0(k)I A:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-13, as applicable.
§ 150.0(k)] B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ I50.0(k)IC:
§ I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§ I50.0(k)1 D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ I50.0(k)I E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
'
requirements of 150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§I50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ I50.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ I50.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ I50.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §150.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ 150.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4:
permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ I50.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§I50.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in §110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ I50.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically tum the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§I50.0(k)9B:
following requirements:
i. Shall comply with § 150.0(k)9A; or
ii. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, §130.4, §140.7 and §141.0.
§I50.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §I50.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in §110.9, § 130.0, &130.2, § 130.4, § 140.7 and § 141.0.
§ I50.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
'110.9,
with the applicable requirements in § 130.0, § 130.2, § 130.4, §140.7 and §141.0.
§I50.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to §130.0(c).
§ 150.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9, § 130.0, § 130. 1, $130.4, § 140.6, and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ I 50.0(k) I 2A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§I50.0(k)l2B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 1 10.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10(6) through §I 10.10(e).
§ 1 10.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 1 10.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§110.10(b)1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§I 10.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 1 10.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§1 10.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
t.
Date
Mrs. Celia Arellano
12/13/2016
System Name
Floor Area
HVAC System
335
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING
CFM Sensible
Total Room Loads 213 41528
Return Vented Lighting 0
Return Air Ducts 0
Return Fan 0
Ventilation 0 0
Supply Fan 0
Supply Air Ducts 0
'
TOTAL SYSTEM LOAD 4,528
PEAK COIL HTG.
PEAK
Heating System
Latent CFM
Sensible
Output per System 17,000
3521 95
3,730
Total Output Btuh 17,000
Output Btuhls ft 50.7
0
Cooling System
0
Output per System 15,600
0 0
0
Total Output Btuh 15,600
352
0
Total Output Tons 1.3
0
Total Output Btuh/sgft 46.6
Total Output s ft/Ton 257.7
3,730
Air System
CFM per System
1,200
HVAC EQUIPMENT SELECTION
Airflow cfm
1,200
LG LMU187HV 9,502 3,609
10,618
Airflow cfmis ft
3.58
Airflow cfm/Ton 923.1
Outside Air %
0.0 %
Total Adjusted System Output 9,502 3,609
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
. 10,618
Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak
26 OF 68 OF '
68 OF
105 OF
'
Outside Air
Li
0 cfm Supply Fan
Heating Coil 105 OF
1,200 cfm
- I �O.Olyi
68 OF
68 OF
r
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
F
1.12/78°F 75/61°F 75/62°F 55/54°F '
Outside Air
Ar
0 cfm
Supply Fan
Cooling Coil 55/54 OF,-.
1,200 cfm
46.5%
75 / 61 OF
75 / 61 OF
EnergyPro 6.7 by EnergySoft User Number: 5732 RunCode: 2016-12-13713:26:25 /D: LQ080216 - Rev1213 Page 14 of 14
t.