05-2267 (SFD)A`� -.
P.O. BOX 1504.
78-495 CALLE TAMPICO
LA QUINTA; CALIFORNIA 92253.
Application Number: C-5
Property Address: 81256 VICTORIA LN
APN: 764-270-999-136 -300234-
Application description: DWELLING - SINGLE FAMILY D
Property Zoning: MEDIUM HIGH DENSITY RES
Application valuation: 192099
4
BUILDING & SAFETY DEPARTMENT
BUILDI^1S-WRMIT .
Owner:
SHEA LA QUINTA
C/O"JEFF MCQUEEN..
8800 N GAINEY CENTER 350
SCOTTSDALE, AZ 85258
Applicant: �rchitect r Engineer:
_ - t: r"
L
LICENSED CONTRACTOR'S DECLARATION
1 hereby affirm under penalty of perjury that -I am licensed under provisions of Chapter 9 (commencing with, '
Section 7000) of Division 3 of the BusinessandProfessionals Code, and my License is in full force and effect.
' - License Class: B �,.LicceennsseNo.: 672285
/Date: A�ontraclor:
OWNER -BUILDER DECLARATION
1 hereby affirm under penalty of perjury that Iam exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5,. Business and Professions Code: Any city or county that requires a permit to
construct; alter,. improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or.
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)..-
1
$500).:1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation; will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds.or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the .
improvements are'not intended or offered for sale" If, however, the,building or improvement is sold within
a one year of completion, the owner -builder will have the burden of proving that he or she did not build. or
improve for the purpose of sale.).
1 _ 1 I, as owner of the property; am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Coder The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.). '
(_) I am exempt under Sec. , B.&P.C.: for this reason
Date:' Owner: '
CONSTRUCTION LENDING AGENCY
Thereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.)... _
Lender's Name:
- Lender's Address: P tA-
LQPERMTf
Contractor:
SHEA HOMES, INC.
81260 AVENUE 62
LA QUINTA, CA 92253
(760) 7.77-6005
Lic.'No.: 672285
VOICE (760) 777-7012 ',
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
WORKER'S COMPENSATION DECLARATION
Ihereby affirm under penalty of perjury one of the following declarations: -
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
-- for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued..
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workerscompensation
insurance carrier and policy number are:,
Carrier NTL UNION INS Policy Number 6436568
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject tote workers' compensation provisions of Section
00 of the Labor Code, I tall forthwith m y with those provisions.
Date: &M63jrA2pplicant:
WAR ING: FAILURE TO SECURE Vtr6R MP$ SATION COVERAGE IS UNLAWFUL, AND SHALL.
.SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, -AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT y
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and her, y authorize representatives
of this cou ty t enter u/on the above-mentioned property for ' pection purpo s.
Date: g8r nature (Applicant or Agent)
Application Number
05-00002267
Permit . .
BUILDING PERMIT
Additional desc'.
Permit Fee
965.00
Plan Check'Fee
627.25
Issue'Date
Valuation
'192099
Expiration Date
12/07/05.
Qty Unit Charge
Per
Extension
BASE
FEE
639.50
93.00 3.5000'THOU
BLDG
100,001-500,.000.
325.50
Permit . . .
MECHANICAL
Additional desc .
- Permit Fee
65.50
Plan Check Fee
16.38
Issue Date . . . .
Valuation
0
Expiration Date
12/07/05.
Qty. Unit.Charge
Per
Extension
BASE
FEE
15.00
1.00 9.0000
EA- MECH
FURNACE <=100K
9.00
.1.00 9.0000
EA MECH.B/C
<=3HP/100K BTU
9.00
4.00 6.5000
EA MECH
VENT FAN
26.00
1.00 6.5000
EA MECH
EXHAUST HOOD
6.50
Permit . .
ELEC-NEW RESIDENTIAL
Additional desc'.
-
Permit Fee
104.16
Plan -Check Fee
26.04
Issue Date . . . .
Valuation . . . .
0
Expiration Date
12/07/05
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
2189.00 .0350
ELEC
NEW RES -,1 OR 2 FAMILY
76.62
627.00 .0200
ELEC
GARAGE OR NON-RESIDENTIAL
12.54
Permit
PLUMBING
Additional desc .
Permit Fee,
147.00
Plan Check Fee•
36.75
Issue Date . . .
Valuation
.0
Expiration Date
12/07/05
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
13:00 6.0000
EA PLB FIXTURE
78.00
•1.00 15.0000•EA
PLB BUILDING SEWER
15.00
_ LQPERMIT
Application Number 05-00002267
Permit . . PLUMBING
r
Qty Unit.Charge Per
Extension
1.00 7.5000 EA PLB WATER-HEATER/VENT.
7.50
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
1.0.0.. 9.000.0 EA PLB LAWN SPRINKLER SYSTEM
9.00-
6.00 .7500 EA PLB GAS PIPE >=5
4.50
1.00 15.0000 EA PLB GAS METER
15.00
------------------------------------------------ -------------------------
Permit' GRADING PERMIT
Additional desc
Permit Fee 15.00 Plan Check Fee
.00
Issue Date Valuation
0
• Expiration Date 12/07/05
Qty Unit 'Charge Per
Extension
BASE' FEE
15.00
---------------------------------------------------------
Special Notes and Comments
SFD - Plan 5210C Lot 136 w/MBR Box Bay
(26 sgft)` & Garage Ext: (109 sgft).
Permit does not include block wall,
pool or driveway approach.
--------------------------------------------------------------------
Other Fees . . . . ART IN PUBLIC PLACES -RES
20.00
DIF COMMUNITY CENTERS -RES
97.00
DIF CIVIC CENTER - RES _
366.00
ENERGY REVIEW FEE
62.73
DIF FIRE PROTECTION -RES
97.00
GRADING PLAN CHECK FEE
.00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
5.00
DIF,PARKS/REC - RES
502.00
STRONG MOTION (SMI) - RES
19.20
DIF STREET MAINT FAC -RES
15.00
DIF TRANSPORTATION -ARES
1098.00
r Fee summary Charged Paid Credited
------- ----------
Due
_ ----------
Perm t Fee Total 1296.66 .00 00
1296.66
. Plan Check, Total 706:42" .00 .00
706.42
Other. Fee Total 2506.93 .00 .00
2506:93
Grand Total 4510.01 .00 .00
4510.01
LQPERMIT
10/11/2005 10:51 FAX PARAGONPSCHIMID 1@ 006/019,
.y
INSULATION CERTIFICATE
• This is to certify that insulation has been installed in conformance with the current energy
regulation, California Administrative Code, Title 24, State of California, in the building at
81=256 VICTORIALANE,107,4'16&PHASEv'11C, LA QUINTA CA
CEILINGS:
TYPE: BLOW MANUFACTURER: Certainteed THICKNESS: R-38
WALLS:
r TYPE: BLOW MANUFACTURER: Certainteed THICKNESS: R-13
GENERAL CONTRACTOR: SHEA HOMES LICENSE#
BY: TITLE:
.PARAGO CHMID BUILDI G PRODUCTS A MASCO Company LICENSE # 221517
BY: BGG TITLE: ACCOUNT REPRESENTIVE DATE: �� 0
Y
JCM Inspections -
. 39725 Garand Cane Suite F
Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-7.72-3895 INSPECTIONS
REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below
Project Name: Project No:
Trilogy @ La Quinta - Shea Homes 02-1109
Project Address: City:.
81-260 Avenue 62 La Quinta, CA
❑✓ IBC
[-]Title 24
Other:
Client: - Sub -Contractor:
Shea La Quinta, LLC DCCCC
General Contractor: Architect: Structural Engineer:
Shea Homes Bassenian Lagoni Borm & Assoc,Inc/Suncoast Post Tension LP
Slump (inches):S Supplier: Superior
Time Sampled: tO ; O Q w�' Mix Design: D83625P
Time in Mixer (min.): st7 Specified Strength (PSI): 4000 ,
Water Added @ Jobsite (gals.): 10 Addmixture: POZZ 322N
Concrete Temperature (F): �""� Truck #:a(, Ticket #:`�
#:-1 LI�
Ambient Air Temperature (F): 4 Field ID Marking: Set A - 4 cylinders
rW�eather:-1-11{_0
Unresolved Items:
❑ None
❑ See Below
Location of Sample: , o�, ,,,� C_Cnr� , ' nf"ayc.
❑ No Samples Taken
Description of Work Inspected: Phase C Lot# LJ+3 Product ,-,I Plante L
QS_G1 V 1 CA n r iia (' Q el QL
11 o
1) Received mill certifications fdr rebar and tendons placed.
2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1),
Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns^(6,7,8/SD-1),, Footings and additional
�Pad
rebar placed as per these details and as noted on S 9 — S 9.a SL4--G i ,n c a '+ N r� ''1 1CT• 1.3 n r c+
Q.x\+on"ooel a' baja �AYN.•r+akow (r- CSC &�CorOcA i
Also, typical details 2, 3/SD-1 and Notes on SNA apply. Checked rebar for grade, size, placement, coverage'and splices. Rebar and tendons were
securely tied and supported off the earth. Accepted for concrete placement.
-1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx . 1 (0 ,
ter.
A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c.
Y
2) Molded 4 cylinders for compression tests with breaks at 7 days (1),•28 days (2) and one for holding purposes.
1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx Verified correct mix design.
I he by certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved
pecifications _applicable building laws. Final report issued at project completion.
Inspector: Jack C. Millin ICC Certifca io No: 0842216-80
Contractor's Representative:
Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page of
i
JCM Inspections
39725 Garand Lane Suite F
Palm Desert, CA 92211
INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895
INSPECTIONS
PRESTRESSED CONCRETE INSPECTION REPORT Date:
Project Name:
Trilogy @ La Quinta - Shea Homes
Project No:
02-1109
Project Address: City:
81-260 Avenue 62 La Quinta, CA
0 IBC
Title 24
Other:
Client: Sub-Contractor:
Shea La Quinta, LLC Sun Coast Tensioning
General Contractor: Architect:
Shea Homes Bassenian Lagoni
Structural Engineer:
Borm & Assoc,lnc/Suncoast Post Tension LP
Size and Type of Tendons: 1/2" Diameter Seven Strand Stress-Relieved Tendons
Jack Machine Calibration: Received Sheet from Sun Coast-Gage Pressure in psi to Machine Load in kips
Sy pp psi to 33.04 kips/33,000 lbs
Calibration Date: Machine # '� � e'%$., O-.-
Phase' ` c„Lot# Products:. Plan (' C, �jl .-�.,, V 1(�o( 1 C_
Weather:
it k-
S A ��
Unresolved®Items:
JR' None
E] See Below
Description of Work Inspected:
Specified
Lot # Location Tendons Elongation (in)
Actual Elongation (in)
Complies within 7% +/- of specified elongation.
Reference 11 h/SN2.
Yes No
p Uro'❑
'Mocn�n .�rrl�eo: t:-ncoso. cx�•
4 3
Cryo' ❑
y �p r e�/w � �� c��! auJ --s'r�
�{' � �!
1 �
LTJ ❑
3A
eg. L4
AS\r� Dn r �.Q�Q .
�� ❑
Er 1:1
❑ ❑
❑ ❑
I h y certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved
pecifications _applicable building laws. Final report issued at project completion.
Inspector: Jack C. Millin ICC Centification,No: 0842216-89
Contractor's Representative:
Copy 1 JCM Innsppec ons Copy 2 Project Superintendent Copy 3 Governing Agency Page of 1
COMPRESSION STRENGTH TEST,RESULTS
Client: Shea La Quinta, LLC
� Dater 9125105
JCM Inspections
39725 Garand Lane Suite F
Project No: . 02-1109
Palm Desert, CA 92211
INSPECTION'S'
Phone- 760-345-5554, - Fax: 760-772-3895
INSPECTIONS
COMPRESSION STRENGTH TEST,RESULTS
Client: Shea La Quinta, LLC
� Dater 9125105
,. Project: Trilogy @ La Quinta -Shea Homes
Project No: . 02-1109
81-260 Avenue 62
.La Quinta, CA 92274
-
Set ID Structure
Age of Test
. Compression Strength
JCM ID Location
Date Cast Cylinder ID (days)
(psi)
Set A Phase 11 C - Lot # 4136 Slab on Grade
7-15-05
Concrete
273-554 Nook
-
Required psi: 4000
639 7• -
3450
.640 28
5050
641 •28 '.
5110
CERTIFIED:
JCM Inspectioni
supplies the service
of compression
strength test results only.
Per ASTMC39