Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-2235 (SFD)
44P.O. BOX 1504 aVOICE 760 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 '` BUILDING &,SAFETY DEPARTMENT �. INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 6/10/05 Application Number: 05-00002235.. Owner: Property Address: 81280 VICTORIA LN SHEA LA QUINTA 'APN: 764-270-999-134 '30.0234- C/O JEFF.MCQUEEN Application description: DWELLING - SINGLE FAMILY DETACHED,' 8800 N GAINEY CENTER 350 Property Zoning: MEDIUM HIGH DENSITY RES SCOTTSDALE, AZ 85258 Application valuation: 240673 Contractor: Applicant: rchitect or E er: SHEA HOMES, INC. 81260 AVENUE 62 X • LA QUINTA, CA 92253 (760) 777-6005 Lic. No.: 672285 - LICENSED CONTRACTOR'S DECLARATION , WORKER'S COMPENSATION DECLARATION +. I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with 1 hereby affirm under penalty of perjury one of the following declarations: .. Section 7000) of Division 3 of the Business and. Professionals Code, and my License is in full force and effect._ I have and willmaintaina certificate of consent to self -insure for workers' compensation, as provided License CI s: 131- License No.: 672285 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is ' K issued. te: �� V J ontractor. �� �i (� t� V ; 1(! 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor *'C Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: 'I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier NTL UNION INS - Policy Number 6436568 following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to_ I certify that, in the performance of the work for which this permit is issued, ) shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I should become subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or / 700 of the Labor Code, I s all forthwith comply itf ose provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by' ![x� //V any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ate: �, _ � plicant: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and •' the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WOR,AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon,.. SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES A CIVIL FINES UP.TO ONE HUNDRED THOUSAND and who does the work himself or herself through his'or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. ' one year of completion, the owner -builder will have the burden of proving that he or she did not build or - improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. -IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State'License Law does,not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who. contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, _ (_ 1 I am exempt under Sec. , B.&P.C. for this reason - the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City , • - of La Quinta, its officers, agents and employees for any act or omission related to the work being _ performed under or following issuance of this permit. I N %I Date: Owner. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within '180 days from date of issuance'of such permit, or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY - permit to cancellation. ' ^ I hereby affirm under penalty of perjury that there is a construction lending•agency for the performance of the I certify that I have read this application and state that the above information is correct. I agree to complywith all - work for which this permit is issued (Sec. 3097, Civ. C.). _ city and county ordinances and state laws relating to building construction, and hereby auth ize representatives of this,co ty to nter upon theabove-mentioned property for i :tion purposes. _ Lender's Name: l/(/� - ate: �� ture (Applicant or Agent): Lender's Address: LQPERMTT� _ Application Number 05-00002235 . Structure Information Construction Type TYPE V - NON RATED Occupancy Type DWELLG/LODGING/CONG <=10 Flood Zone NON -AO FLOOD ZONE Other struct info CODE EDITION 2001 CBC FIRE SPRINKLERS NO GARAGE SQ FTG 719.00 PATIO:SQ FTG. 214.00 NUMBER OF UNITS. 1.00 1ST FLOOR SQUARE.FOOTAGE 2769.00 Permit . . . BUILDING PERMIT Additional.desc ` Permit Fee . . . 1133.00 Plan Check Fee 184.11 Issue Date Valuation . . . . 240673 Expiration Date 12/07/05 Qty Unit Charge Per Extension 'BASE'FEE 639.50 141.00 3.5000 THOU BLDG 100,001-500,000 493.50 Permit MECHANICAL Additional desc . Permit Fee 72.00 Plan Check Fee °4.50 Issue Date Valuation 0 Expiration.Date 12/07/05. Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 5.00 .6.5000 EA MECH VENT FAN 32.50 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit ELEC-NEW RESIDENTIAL Additional desc . Permit Fee 116.2.0 Plan Check Fee 7.26 Issue Date Valuation 0 Expiration Date 12/07/05 Qty Unit Charge Per Extension BASE FEE 15.00 2769.00 0350 ELEC NEW RES - 1 OR 2 FAMILY 96.92 214.00 .0200. ELEC."GARAGE OR NON-RESIDENTIAL 4.28 LQPERMTT .. _ - .. .. IV :Application Number 05-00002235 Permit PLUMBING Additional desc . ". Permit Fee . . . . . 171.00 Plan Check Fee 10.69 Issue.Date Valuation 0 - Expiration Date 12/07/05 } " Qty` Unit Charge Per Extension BASE FEE 15.00 17.00 6.0000 EA PLB FIXTURE 102.00 1.00 15.0000 EA PLB BUILDING SEWER'. 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT' 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9:0000 EA PLB LAWN,SPRINKLER SYSTEM 9.00 6.00 .7500 EA PLB GAS PIPE >=5 4.50 1.00 15-.0000 EA PLB GAS METER 15.00 Permit GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . Valuation 0 Expiration Date 12/07/05 Qty Unit'Charge Per Extension ` BASE FEE 15.00 Special Notes and Comments SFD - LOT 134, 6430B, 2769 8F. PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL, SPA OR DRIVEWAY APPROACH. 75% REDUCTION TO ' PLAN CHECK FEE 'DUE TO MULTIPLE ISSUANCE OF SAME PLAN TYPE Other. Fees . . . . . . . ART IN PUBLIC PLACES-RES •101.68 DIF COMMUNITY CENTERS-RES 97.00 DIF CIVICCENTER - RES" 366.00_ ENERGY REVIEW"FEE 18.'41" DIF FIRE PROTECTION-RES' 97.00 " GRADING PLAN CHECK FEE .00 DIF LIBRARIES'- RES 225.00 ` DIF PARK MAINT - RES 5.00 _FAC DIF PARKS/REC - RES 502.00 , STRONG MOTION (SMI) - RES 24.06 DIF STREET.MAINT FAC-RES 15.00 DIF TRANSPORTATION.- RES 1098.00 Fee summary -Charged Paid- Credited Due -: Application Number 05-00002235 - ----.------- - - - - -- --- Permit Fee`Total. ---- - - ---' ---- 1507.20- - - - ------ - ,.00 - - - -- .00 ---- - - - - -- 1507.20 ' Plan Check Total 206,56 00 .'00 206.56 Other Fee-Total 2549.15" .00 00. 2549.15 Grand-Total 4262.91• .00 .00 •4262.91. LQPERMIT• 10/11/200"5101:51 FAX PARAGONPSCHIMID IaOO7/019 INSULATION CERTIFICATE • This is to certify that insulation has been installed in conformance with the current energy regulation, California Administrative Code, Title 24, State of California, in the building at 81-280 VIC O1R A LANE, LfOf`;4134;PHASE 11-C, LA QUINTA CA r.. CEILINGS. TYPE: BLOW MANUFACTURER: Certainteed THICKNESS: R-36 WALLS: TYPE: BLOW MANUFACTURER: Certainteed THICKNESS: "R-13 GENERAL CONTRACTOR: SHEA HOMES LICENSE # BY: TITLE: PARAGON CHMID BUILDING PRODUCTS A MASCO Company. LICENSE # 221517 BY: ACCOUNT REPRESENTIVE DATE, 0 0 0 CaICERTS Certified Rating November, 3 2005 tis Compliance rating is for the home located at: 81280 Victoria Lane e Conditioned Volume: 0 Cubic Feet . La Quinta CA, 92253 Certificate Number: CC3-1798351719 t. Date Inspected: October, 31 2005 6.0 Ca10ERTS Rater: William Henson C CC2004076 HERS Analyst: N/A %,E Builder/ Developer: Shea Homes, Inc. Project: Trilogy @ La Quinta T , Phase: Phase 11C _ Plan Name: 643_0 Lot Number: 134 Specifics about this home: General Information Cooling Equipment: Conditioned Floor Area: 2800 Square Feet Conditioned Volume: 0 Cubic Feet . Front Orientation: N/A Number of Stories: 1 Heating and Cooling Systems Heating Equipment: Furnace: 0.8 Cooling Equipment: AC: 12 Heating Equipment: Furnace: 0.8 Cooling Equipment: ACSplit: 12 ISAC Air Distribution ested Duct Design Compliance: Duct Location: Attic Duct Leakage Target: 6.0 Duct Insulation R -Value: 6 Air Infiltration Blower Door Target: 96.0 Water Heating S stem P=osed TY Size I Fuel 1EF1 Distribution Water Heating S stem Actual TY Size I Fuel I EF Distribution Testinn Results Main System HVAC System Area Tested Duct Leakage: es - Passed Tested Leakage Flow in CFM: 89 00cfm/ton x number of tons: 1600 Leakage Percentage 100 x Test Leakage/Fan Flow 5.6 ested TXV: I Yes -Passed ermostatic Expansion Valve is installed and Access is vided for inspection. ested Duct Design Compliance: N/A ested Duct in Conditioned Space: N/A I � 1 Buildina Envelone Surface Area Proposed Actual R Value I U Factor R Value U Factor Windows FX TESTED (PAGE 1 OF 2) OAPPROVED AS PART OF SAMPLE GROUP FIRM: BCI TESTING ADDRESS: 77-760 COUNTRY CLUB DRIVE, SUITE I PALM DESEERT, CA. 92211 PHONE: 760-772-2954 CERTIFYING SIGNATURE DATE il Prosed Actual Orientation Area U U SHGC Value SHGC Value FX TESTED (PAGE 1 OF 2) OAPPROVED AS PART OF SAMPLE GROUP FIRM: BCI TESTING ADDRESS: 77-760 COUNTRY CLUB DRIVE, SUITE I PALM DESEERT, CA. 92211 PHONE: 760-772-2954 CERTIFYING SIGNATURE DATE il ested Reduced Duct Surface Area: N/A New S stem HVAC System sted Duct Leakage: es - Passed sted Leakage Flow in CFM: 70 OOcfm/ton x number of tons: 1200 Leaka a Percentage 100 x Test Leaka a/Fan Flow 5.8 ested TXV: Yes -Passed ermostatic Expansion Valve is installed and Access is rovided for inspection. ested Duct Design Compliance: N/A ested Duct in Conditioned Space: N/A ested Reduced Dud Surface Area: N/A ested Infiltration Reduction Credit: N/A The energy efficiency rating of this home is determined using California Home Energy Rating System (C -HERS) rules. The rating considers heating, cooling and water heating and assumes average weather, thermostat settings, and quantities of hot water for a typical household. Actual energy use will vary according to occupant behavior. This Rating Completion Summary is provided only after the features listed have been verified and approved by the CalCERTS Certified Rater shown above. If you have a concern or complaint regarding this report of the services used in obtaining it, you may contact: CaICERTS - Customer Service P.O. Box 6600, Folsom, CA 95763. (PAGE 2 O/F/2) PHASE (( V LOT • I , JCM Inspections 39725 Garand Lane Suite F. I Palm Desert, CA 92211 _ I N S P E C T I o`N S Phone: 760-345-5554 - Fax: 760-772-3895 I N S P E C T I o N s REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109, Project Address: City: 81-260 Avenue 62 La Quinta, CA �✓ IBC Title 24 Other: Client: Sub -Contractor: Shea La Quinta, LLC DCCCC General Contractor: Architect: Structural Engineer: Shea Homes Bassenian Lagoni Borm & Assoc,lnc/Suncoast Post Tension LP Slump (inches): r� © Supplier: Superior Time Sampled: p`Mix Design: D83625P Time in Mixer (min.):.SD Specified Strength (PSI): 4000 Water Added @ Jobsite (gals.): ��¢ Addmixture: POZZ 322N Concrete Temperature (F): $a Truck #:33"-1 Ticket #: �� 4 Ambient Air Temperature (F): C13 Field ID Marking: Set A - 4 cylinders Weather: Unresolved Items: None Q See Below Location of Sample: (s X c �rr�-, r� c "'•�! C ®hv� ,� ❑ No Samples Taken Description of Work Inspected: Phase . Lot�#j�U 13 Product.3 Plan 4j Q� 1 1•C tl( i O' r n -1-191- M 1) Received mill certifications for rebar and tendons placed. 2) Typical exterior Footings including Garage Footings/Door (I1,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1), Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD-1), Pad Footings and additional rebar placed as per these details and as noted on Also, typical details 2, 3/SD-1 and Notes on SN -1 apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were, securely tied and supported off the earth. Accepted for concrete placement. 1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c. 2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes. % l>� 1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx ' Verified correct mix design. I he eby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved R jpecifications _applicable building laws. Final report issued at project completion. Inspector: Jack C. Millin ICC Certification No: 0842216-80 Contractor's Representative: Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Pageof '. T 1 x ` ~~ ~ - ~. m"� Copy 1 JCIVI Inspections Copy u Project Superintendent Copy3 ovvemnnAyency pooe_�_m�___ � JCIVI Inspections 39725. Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: .760-345-5554 - Fax: 760-772-3895 INSPECTIONS PRESTRESSED CONCRETE INSPECTION REPORT Date: -7,,or7 _CxZ Aroject Narre': Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: IBC 81-260 Avenue 62 La Quinta, CA Title 24 Client: Sub -Contractor: S . hea La Quinta, LLC Sun Coast Tensioning Other: General Contractor: Architect: Structural Engineer: Shea Homes Bass6nian Lagoni Borm & Assoc, Inc/Suncoast Post Tension LP Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons Unreso , lvedlie - rns: Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips z�;H 0-0 psi to 33.04 kips/33,000 lbs None E] see Below Calibration Date: Machine # Phase c- Lot# LA L -S � Product PlareotA R� si— Nt� I C%, UG V`LR__1 Description of Work ln�pected:' Actual Elongation (in) Specified Complies within.7% +/-of specified elongation. Lot # Location Tendons Elongation (in) Reference 11h/SN2. LA 134 Yes No E El Er 1:1 ER El E9- El 1:1 El I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved pecifications -applicable building laws. Final report issued at project completion. Inspector: Jack�C��Millin , ICC Certificatio N :0 42216-89 Contractor's Representative: Copy 1 JCIVI Inspections Copy u Project Superintendent Copy3 ovvemnnAyency pooe_�_m�___ � JCM Inspections 39725, Garand Lane Suite F 'Palm Desert, CA 92211 COMPRESSION STRENGTH TEST RESULTS Client: Shea La Quinta, LLC Date: 9/25/05 Project: Trilogy @ La Quinta - Shea Homes Project No: 02-1109 81-260 Avenue 62 La Quinta, CA 92274 Set ID Structure Age of Test Compression Strength JCM ID Location Date Cast Cylinder ID (days) (psi) Set A.' Phase 11 C - Lot #4134 ` Slab on Grade 7-19-05 Concrete 273-563 -Bedroom Z Required psi: 4000 651 7 4180 - 652 28 5680 ' 653 28 574r0,� '`